13-813 516 Hansen St S plans
COMcheck Software Version 3.9.2 Mechanical Compliance Certificate 2009 IECC Section 1 : Project Information Project Type:Alteration Project Title : Downtown Renaissance-TF Brick House Construction Site: Owner/Agent: Designer/Contractor: Twin Falls,ID 83301 Jeff Hepworth David Bastow Downtown Renaissance McClure Engineering,Inc. r Twin Falls,ID 83301 507 Main Av.W. Twin Falls, ID 83301 208-734-9015 dbastow@mcclure-engineering.com Section 2: General Information Building Location(for weather data): Twin Falls,Idaho Climate Zone: 5b Section 3: Mechanical Systems List Quantity System Type&Description 2 HVAC System 1 (Single Zone): Heating:2 each-Central Furnace,Gas,Capacity=74 kBtu/h Proposed Efficiency=95.00%Et,Required Efficiency=80.00%Et Cooling:2 each-Split System,Capacity=30 kBtu/h,Air-Cooled Condenser Proposed Efficiency=14.50 SEER, Required Efficiency=13.00 SEER Fan System: FAN SYSTEM 1 I SW Banquet Area--Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Constant Volume, 1225 CFM, 1 motor nameplate hp Section 4: Requirements Checklist Requirements Specific To: HVAC System 1 : 1Y-��. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) l/ `. Equipment minimum efficiency: Split System: 13.00 SEER Generic Requirements: Must be met by all systems to which the requirement is applicable: �1. Plant equipment and system capacity no greater than needed to meet loads Exception(s): ri Standby equipment automatically off when primary system is operating Multiple units controlled to sequence operation as a function of load Lirl `• Minimum one temperature control device per system ///A [-1 3. Minimum one humidity control device per installed humidification/dehumidification system y(4. Load calculations per ASHRAE/ACCA Standard 183. p(5. Automatic Controls:Setback to 55°F(heat)and 85°F(cool);7-day clock,2-hour occupant override, 10-hour backup Exception(s): l] Continuously operating zones $66. Outside-air source for ventilation;system capable of reducing OSA to required minimum g7. R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly Exception(s): Project Title: Downtown Renaissance-TF Brick House Report date: 05/24/13 Data filename:0:12013113-02 Downtown Renaissance LLC(Old Muggers Bldg)\Engineering\Downtown Ren 2nd Floor COMcheck.cck Page 1 of 3 Ducts located within equipment Ducts with interior and exterior temperature difference not exceeding 15°F. ± i. Mechanical fasteners and sealants used to connect ducts and air distribution equipment Ducts sealed-longitudinal seams on rigid ducts;transverse seams on all ducts; UL 181A or 181 B tapes and mastics �(10. ot-water-pipe-insrtletien.. -i-.&in-faryipes--l-&in-and 2-in-for-pipes">-1-.-5-in: GtiiUed water/refrigerantNaciwepipe insulatia; 1.5 in,for pies<=1.5 in.and 1.5 in.for pipes>1.5 in. 6tear�ipe-insalatiefr.--9-5�iwr.-fa-pipes=-'I�5-i�..aad.3-in�fe-r-pipes-�..1-5-in. Exception(s): Ej Piping within HVAC equipment. Fluid temperatures between 55 and 105°F. Fluid not heated or cooled with renewable energy. LJ Piping within room fan-coil(with AHR1440 rating)and unit ventilators(with AHRI840 rating). Runouts<4 ft in length. 0�11.Operation and maintenance manual provided to building owner P(I2.Thermostatic controls have 5°F deadband Exception(s): Thermostats requiring manual changeover between heating and cooling Special occupancy or special applications where wide temperature ranges are not acceptable and are approved by the authority having jurisdiction. 13.Balancing devices provided in accordance with IMC(2006)603.17 14.Demand control ventilation(DCV)present for high design occupancy areas(>40 person/1000 ft2 in spaces>500 f:2)and served by systems with any one of 1)an air-side economizer,2)automatic modulating control of the outdoor air damper,or 3)a design outdoor airflow greater than 3000 cfm. Exception(s): eSystems with heat recovery. ❑ Multiple-zone systems without DDC of individual zones communicating with a central control panel. Systems with a design outdoor airflow less than 1200 cfm. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. L�/,5.Motorized,automatic shutoff dampers required on exhaust and outdoor air supply openings Exception(s): Gravity dampers acceptable in buildings<3 stories A//A O 16.Automatic controls for freeze protection systems present d1A Fi 17.Exhaust air heat recovery included for systems 5,000 cfm or greater with more than 70%outside air fraction or specifically exempted Exception(s): [-1 Hazardous exhaust systems,commercial kitchen and clothes dryer exhaust systems that the International Mechanical Code prohibits the use of energy recovery systems. Systems serving spaces that are heated and not cooled to less than 60°F. [� Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. Heating systems in climates with less than 3600 HDD. Cooling systems in climates with a 1 percent cooling design wet-bulb temperature less than 64°F. Systems requiring dehumidification that employ energy recovery in series with the cooling coil. Laboratory fume hood exhaust systems that have either a variable air volume system capable of reducing exhaust and makeup air volume to 50 percent or less of design values or,a separate make up air supply meeting the following makeup air requirements: a)at least 75 percent of exhaust flow rate,b)heated to no more than 2°F below room setpoint temperature,c)cooled to no lower than YF above room setpoint temperature,d)no humidification added,e)no simultaneous heating and cooling. Section 5: Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application.The proposed mechanical alteration project has been designed to meet the 2009 IECC,Chapter 8,requirements in COMcheck Version 3.9.2 and to comply with the mandatory requirements in the Requirements Checklist. -j� j� J A LOl S trt)"J/ <`/ l«�111! 't'l°' '�Z 2 A !Gf �1='Elf Name-Title Signature Date Section 6: Post Construction Compliance Statement Project Title: Downtown Renaissance-TF Brick House � � Report date: 05/24/13 Data filename:O:\2013\13-02 Downtown Renaissance LLC(Old Muggers Bldg)\Engineering\Downtown Ren 2nd Floor COMcheck.cck Page 2 of 3 ❑ HVAC record drawings of the actual installation,system capacities, calibration information,and performance data for each equipment provided to the owner. HVAC O&M documents for all mechanical equipment and system provided to the owner by the mechanical contractor. Written HVAC balancing and operations report provided to the owner. The above post construction requirements have been completed. Principal Mechanical Designer-Name Signature Date Project Title: Downtown Renaissance-TF Brick House Report date: 05/24113 Data filename:O:\2013\13-02 Downtown Renaissance LLC(Old Muggers Bldg)\Engineering\Downtown Ren 2nd Floor COMcheck.cck Page 3 of 3 —rot, K��t w (4ti�4 A-z,-�k4 f r�t,->l O" - 2± �oo A ,t,t C�71f C>U 4� 1 BUIIil, I: Nil c t;oOtz Vo l`�tG(4 = 8'-4 ��l • c z -' r M ell/ IN D :A- 5'-4„ >, 2'-10' 0 Lo i y ' 2 3 c mw- i 0 .00 RECEIVE ® JUN 18 2013 d CITY OF TWIN FALLS PLANNING&ZONING I I 1 I I I I I I I I I I ® SYMBOL LEGEND: I I I I I �- -� 1 201 A-2 ROOM NUMBER/OCCUPANCY GROUP 1 I I I 114 OCCUPANT LOAD I I I I ® ® I I 74 OCCUPANT LOAD USING DOOR OR STAIR I I I RECILI 1 I I ®I 74 I® I I I ' MINIMUM EGRESS EGRES WIDTHOPR ED(SEE S / IXCEPTION IN SECTION 3406.E OF IBC I '"""`a I DHI SIGN AND EMERGENCY MEN'S LIGHTING 202A- 1 •I (FUTURE) BANQUETROM � EXISTING EMERGENCY LIGHTING 206 A-2 KI MECH = 201 A-2 o. B 203 A- 02A108 I 1209 1 A-2 I ® EXISTING EXIT SIGN W M ROOM E I ROOM 208 A-2 i1N i EXISTING EXITSIGN-DIRECTIONAL 2= 204 A-2 I NEW EXIT SIGN AND EMERGENCY w I I LIGHTING . I NEW EMERGENCY LIGHTING 205 A- 20 n) 4• W Z 4 ® NEW EXIT SIGN F I LOBBY 45'(SEE IFC NEW A I I O 17 TABLE 4604.7•EG I I 207 A-2 ® NEW EXIT SIGN-DIRECTIONAL WIDTH PER OCCUP � N 74 SERVED) SECOND FLOOR PLAN N Z = SCALE.+,-1'-0' 04 NEW HORN STROBE PER IFC O o U Q F W Cd © W NEW FIRE EXTINGUISHER PER IFC-TYPE Q 0 AS INDICATED ON DRAWING 0. PER POST ROOM MAXIMUM OCCUPANT LOAD `CLIENTIBC : PROJECT: FENCED PATIO U� ti \ „4 A ,(OCCUPANT ® �'y CODE ANALYSIS: (OCCUPANT LOADD INCLUDED INDED IN 36 92 ® Q ca PLUMBING FIXTURE dNLSa 5 U O O 2Z LIJ V •U� VV SCOPE:THIS CODE ANALYSIS IS FOR A TENANT IMPROVEMENT OF THE FIRST AND SECOND FLOORS OF THE EXISTING Z — — / L BUILDING FOR USE AS A BAR d RESTAURANT.THE BASEMENT AND THIRD FLOOR ARE NOT CONSIDERED AS PART OF ® THIS TENANT IMPROVEMENT PROJECT. J = Q O N 36 APPLICABLE CODE:THIS ANALYSIS IS BASED ON THE 2009 EDITION OF THE INTERNATIONAL BUILDING CODE AND 3W OC C0 ZUSES PROVISIONS FOR (n i 4 OCCUPANCY GROUP:A-EXISTING IN[RAPIER 34.OR FIRST AND SECOND FLOORS. Z Z W I r CONSTRUCTION TYPE:ASSUMED TO BE TYPE V-B. W R ES U RANT I FLOOR AREA: BASEMENT 6,996 SF,FIRST FLOOR 7,380 SF,SECOND FLOOR 6,100 SF,THIRD FLOOR 1,200 SF.TOTAL I I 21,676 SF. 1102 A-2 S6 E NUMBER OF STORIES:EASEMENT+THREE 8 I I A-2 THE BUILDING 5 FULLY SPRINKLERED.ADDITIONAL EXIT SIGNAGE AND EMERGENCY LIGHTING ARE SHOWN ON I * 1 DRAWINGS. Qv'ewhave ADDITIONAL PLUMBING FIXTURES HAVE BEEN PROVIDED TO MEET CHAPTER 29 REQUIREMENTS FOR THE FIRST AND C] 7 7• ®2A106 SECOND FLOOR INTERIOR SPACE ONLY. qg 11 COOLER I I approved 0 L=KITCHEN ,09 A z w ATOR 103 A-2 I -- � I Subject cti�i112 2 I IKRCHENw 106 A-2 KITCHEN I I I A-2 I I Z KEYNOTES: Q 1 `r Z � __j R ® 1.EXISTING FRAME AND GLASS WALL TO BE REMOVED. 2.SEE STRUCTURAL FOR NEW FLOOR FRAMING IN THIS AREA B#A R REST AURA f g -- NIGHT CLUB 3.EXISTING SPIRAL STAIRWAY TO BASEMENT.SECURE AT FIRST FLOOR WITH LOCKED CHAIN TO L1J a l PREVENT PUBLIC ACCESS TO BASEMENT. Q �B 101 A-2 4.PROVIDE LOCKING GATE SECURE AT FIRST FLOOR TO PREVENT PUBLIC ACCESS TO BASEMENT. ��� 02AIOB S.MODIFY ELEVATOR CONTROLS 1n PREVENT PUBLIC ACCESS 70 BASEMENT AND THIRD FLOOR WOMENS 111 A-2 O 6.PROVIDE LOCK ON DOOR TO PREVENT PUBLIC ACCESS TO THIRD FLOOR. 00 ,DS A_2 s4 I I I 36 6. I ® 1 I I 1 GENERAL NOTES: ' _ __ _—gyp __ __ 1.CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING OF BUILDING CONSTRUCTIONAND FINISHES 41SIONS WHICH ARE DISTURBED BY DEMOLITION OR CONSTRUCTION ACTIVITY. DE ON __ __ 65 ® 37 585� 2.ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND ORDINANCES. ® 817M3 ADDED 3.ALL WORK SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT. IJGHTI I I L * 4.ALL FINISH MATERIALS SHALL COMPLY BE SELECTED AND/OR APPROVED BY THE OWNER AND SHALL MEET THE ® W113 ADDED PATIO APPLICABLE CLASSIFICATION REQUIREMENTS OF IBC CHAPTERS. &7/13 ADDED I 65 I I 3 2 I 36 I I S.TOILET FIXTURES AND ACCESSORIES SHALL BE AS SPECIFIED IN THE PLUMBING DRAWINGS AND AS SELECTED 0 c^�.�n AND/OR APPROVED BY THE OWNER.CONTRACTOR SHALL PROVIDE BLOCKING AS RECOMMENDED BY THE TOILET 8 yT/�3 REVISED NOTE I I W I ACCESSORY MANUFACTURER. 6.FINISHES AND CONSTRUCTION IN NEW TOILET ROOM SHALL COMPLY WITH IBC SEXTON 1210.FLOOR AND WALL ® F/7/13 ADDED EXfi SI BASE MATERIALS SHALL HAVE A SMOOTH,HARD AND NON-ABSORBANT FINISH.WALL BASE SHALL BE COVED AND EXTEND A MINIMUM OF 4•UP WALL.WALLS AND PARTITIONS WITHIN 2'OF URINALS AND WATER CLOSETS SHALL FIRST FLOOR PLAN 8 HAVE PROVIDE SMOOTH, HARD SAIGND GE NO -AABSORRA T FINISH TO A MINIMUM HEIGHT OF 4'-0'ABOVE THE FLOOR. SHEET#. ER ADA. 65 I I S I 65 1 SCALE.�'-1-0• - 140 119.5' `8, �7, �6, �5, `4, �3, �2, �1,, 0 qF 2 I I^I � 0 I 6,_4" Z -- of\ -4 a ❑ BACK SIDE el el 'rn t t0 C 5 a N N _ � I I o n-1 0 0 /D\ 0 0 0 0 0 SOAP SANITARY GRAB TOILET MIRROR SURFACE LAVATORY TOILET TOILET SEAT URINAL E i DISPENSER NAPKIN BAR TISSUE MOUNTED COVER DISPENSER L DISPENSER DISPENSER PAPER TOWEL `a DISPENSER R (B�01'L ET ACCESSORIES FIXTURE MOUNTING HEIGHTS4°= 1'-C" 2 220 ui C E 6 F 0 6 6 K A � 7 0 7 C C LILI i t II ° �vy� ° \ \ Q71 �� 7 Ir z Z — - -- ------------- ---- w ¢i ---- —G- iEi ® �MEN'S RESTROOMMEN'S RESTROOM 0 MEN'S RESTROOM 0 E4"=1'-O" txt C SCa.E:1/4°= 71 SCALE:1/4'= V-a° m, CLIENT: PROJECT: i ca I I � ZZ Z V Zoo Z KEYNOTES: GENERAL NOTES: O 1.CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING OF BUILDING CONSTFINISHESONAND FINISHES 1.DUSTING DOOR AND HARDWARE TO BE RELOCATED. J = (n 2.NEW 36"DOOR TO MATCH EXISTING WITH PUSH/PULL HARDWARE&CLOSER. WHICH ARE DISTURBED BY DEMOLITION OR CONSTRUCTION ACTIVITY. c O Z (n 3.NEW WALL CONSTRUCTION-TO MATCH EXISTING-PROVIDE FULL THICK GATT SOUND 2 ALL WOE SHALL CONFORM TO ALL APPLICABLE CODES AND ORDINANCES. L INSULATION.. 3.ALL WORK SHALL COMPLY WITH THE AMERICANS WITH DISABILITIES ACT. N ARTIAL SECOND FLO R PLAN 4.ALL ITNLSH MATERIALS SHALL COMPLY BE SELECTED AND/OR APPROVED BY THE OWNER AND SHALL MEET THE 4.EXISTING GLAZING AND FRAME TO BE REMOVED-CONSTRUCT NEW WALL. APPLICABLE CLASSIFICATION REQUIREMENTS OF IBC CHAPTER 8. Z Z Z 5.ADA COMPLIANT TOILET PARTITION.MATERIAL AND FINISH TO BE APPROVED BY OWNER. O W A SCALE:1/4"= wt S.TOILET FIXTURES AND ACCESSORIES SHALL BE AS SPECIFIED IN THE PLUMBING DRAWINGS AND AS SELECTED O Q 6.PAINTED;°TYPE X GYP BD-SEE ALSO GENERAL NOTE 6. AND/OR APPROVED BY THE OWNER. CONTRACTOR SHALL PROVIDE BLOCKING AS RECOMMENDED BY THE TOILET 7.4'-W MIN.HEIGFIT WAINSCOT-MATERIAL SHALL BE SELECTED AND/OR APPROVED BY OWNER-SEE ACCESSORY MANUFACTURER cd ALSO GENERAL NOTES 4 AND 6. 6.FINISHES AND CONSTRUCTION IN NEW TOILET ROOM SHALL COMPLY WITH IBC SECTION 1210.FLOOR AND WALL 8.PROTECTIVE WRAP AT SUPPLY AND DRAIN LINES UNDER LAV PER ADA BASE MATERIALS SHALL HAVE A SMOOTH,HARD AND NON-ABSORBANT FINISH.WALL RASE SWILL BE COVED AND --- --- EXTEND A MINIMUM OF 4'UP WALL WALLS AND PARTITIONS WITHIN 2'OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,HARD AND NON-ABSORBANT FINISH TO A MINIMUM HEIGHT OF 4'-0'ABOVE THE FLOOR. 7. PROVIDE ACCESSIBLE SIGNAGE PER ADA O2 LL O 0 ce Z ON U L11 LLJ N N Z wW z2 REVISIONS Q DATE I DIEsmPnoN ,&14.22.13�RELOCATEDOORS B 6IB/13 ADDED GRAB aNtS SHEET#: A- 1 I �yS,ONAL E 0 O DOWNTOWN a 346 d'pp�0 TWIN FALLS, ID �xOM mmm M ILmm� ^ O N w >W O _ N O J- Q U' ♦- 2LLI/100 N O g0au ui Z DRAWING INDEX LEGEND/ABBREV. GENERAL NOTES "=£mLL Go 0. o -, U) MT-1 TITLE SHEET 'ttlletl l wtlmfu3nsas 1tl0INtlNO3W LEGEND/ABBREVIATIONS M-1 SECOND FLOOR PLAN SYMBOL DESCRIPTION 1.ALL JOB SITE DIMENSIONS,CLEARANCES,AND CONDITIONS ARE TO BE VERIFIED PRIOR TO ORDERING OF EQUIPMENT OR START OF WORK. � a � GATE VALVE 2.CONTRACTOR SHALL LEVEL AC UNITS AND ANCHOR(AS PER IMC)AND SEAL ALL PENETRATIONS. � N /� CAP 3.ANY STEEL PIPE WELDING TO BE BY A CERTIFIED WELDER. ► }� } CDM_Z DETAILS CHECK VALVE 4.SYSTEM WORK SHALL COMPLY WITH LATEST IMC,IFGC,UPC,NEC,IFC AND ALL APPLICABLE LOCAL CODES OF STATE,COUNTY,AND CITY REQUIREMENTS. m C p w -I�I- Q UNION 5.ALL DUCTWORK TO BE GALVANIZED SHEET METAL AND INSTALLED AND REINFORCED ACCORDING TO SMACNA 1"STATIC PRESSURE SEAL CLASS'C'STANDARDS. B1nt'7D � M-3 SCHEDULES ®OR® CEILING DIFFUSER 6.INSTALLTURNING VANES IN ALL 90°ELBOWS OF RECTANGULAR DUCT. wftx THERMOSTAT(PROGRAMMABLE) 7.ALL SUPPLY AND RETURN DUCTWORK IN UNCONDITIONED SPACE TO BE LINED WITH MIN.1"ACOUSTICAL LINER AND/OR WRAPPED WITH THERMAL INSULATION TO BRING UPTOAMIN.R-5 COMBINED INSULATION LEVEL AND COMBINED R-8 MIN.OUTSIDE THE BUILDING ENVELOPE.WRAP OR LINE OUTDOOR AIR DUCTWORK WITHIN BUILDING ENVELOPE MANUAL VOLUME DAMPER WITH MIN.R-8 INSULATION.DUCT LINERS SHALL BE COATED AND SEALED PER ASTM C1071. 8.DUCT SIZES AS SHOWN ARE NET DIMENSIONS. EXPOSED INTERIOR DUCT TO BE PAINT LOCK ROUND METAL SPIRAL DUCT. RECTANGULAR OR ROUND DUCT IS ALLOWED WITH CLIENT: PROJECT: __.(-3E-iE- TO BE REMOVED THE SAME NET OPENING AREA AS THAT SHOWN.(0.08"S.P.LOSS PER 100'DUCT.) XX EQUIPMENT CALLOUT 9.PROVIDE AIR CONDITIONING UNITS,ELECTRICAL COMPONENTS AND CONNECTIONS THAT ARE UL LISTED AND LABELED. X 10.AIR CONDITIONING UNITS,WITH GAS HEATING CAPABILITIES,SHALL BE INSTALLED TO COMPLY WITH AGA SAFETY STANDARDS AND APPLICABLE PROVISIONS OF (E) EXISTING INTERNATIONAL FUEL GAS CODE. PROVIDE SHUT OFF VALVE AND DIRT LEG AT EACH FURNACE. � (N) NEW 11.USE SCH.40 PVC PIPE FOR FURNACE VENT AND COMBUSTION AIR AS APPROVED BY THE MANUFACTURER. of J Uj (R) REPLACE 12.A/C-UNITS SHALL BE INSTALLED WITH VIBRATION ISOLATOR PADS AND AN APPROVED MEANS OF SUPPLEMENTAL RESTRAINT. Z Z Z I 1 (RL) RELOCATE 1 3.ALL DUCTWORK TO BE GALVANIZED STEEL SHEET METAL AND INSTALLED IN AN ACCEPTED WAY TO THE CURRENT SMACNA HVAC DUCT CONSTRUCTION STANDARDS.EXPOSED z O 0 Z INTER' U OR DUCT TO BE PAINT LOCK ROUND METAL SPIRAL DUCT.ROUND DUCTWORK SHALL BE WITH SPIRAL LOCKSEAM CONSTRUCTION WITH NORMAL LENGTHS NOT LESS O Q AFf ABOVE FINISHED FLOOR THAN 12 FT.MINIMUM THICKNESS OF DUCT SHALL BE AS FOLLOWS: J U I.- WIDTH OF DUCT SIZE OF ROUND DUCT GA GALV.OR STAINLESS STEEL ALUM.THICK. O Z N OSA OUTSIDE AIR 0"TO 12" 0"TO 14"0 26 0.020" Z 13"TO 30" 15"TO 26"0 24 0.025' W En N Lq SA SUPPLY AIR 31"TO 54" 23"TO 36:fb 22 0.032" RA RETURN AIR 14.ALL HEATING AND COOLING UNITS SHALL BE CONNECTED WITH FLEXIBLE CONNECTORS NOT LESS THAN 4"WIDE. Q O Z U Uj HRV HEAT RECOVERY VENTILATOR 15,AIR SYSTEM SHALL BE BALANCED BY AN APPROVED CONTRACTOR,TEST AND BALANCE REPORT SHALL BE SUBMITTED FOR ENGINEER APPROVAL, SD SMOKE DETECTOR 16.INSULATE ALL REFRIGERANT SUCTION LINE PIPING WITH ENERGY CODE REQUIRED 1 1/2"THICK ARMAFLEX OR EQUAL INSULATION.ALL OUTDOOR EXPOSED INSULATION SHALL BE PAINTED WITH UV PROTECTIVE PAINT. -G- GAS LINE 17.ALL PIPES AND DUCT PENETRATION OF EXTERIOR WALLS OR ROOF SHALL BE FLASHED AND COUNTER FLASHED WEATHER TIGHT. C- CONDENSATE DRAIN 18.24V.CONTROL TRANSFORMER,CONTROLS,CONTROL RELAYS,ETC.,CONTROL WIRING AND CONDUIT SHALL BE BY THE MECHANICAL CONTRACTOR OR HIS CONTROLS SUBCONTRACTOR AND 110V.AND ABOVE POWER WIRING SHALL BE BY THE ELECTRICAL CONTRACTOR.ALL POWER WIRING AND CONTROL WIRING SHALL BE IN CONDUIT, REFRIGERATION LINES EXCEPT LOW VOLTAGE WHICH IS NOT IN AN EXPOSED AREA. -------- j RETURN AIR DUCT 19. CONTRACTOR SHALL COORDINATE AND APPROVE PIPE PENETRATIONS AND EQUIPMENT LOCATIONS PRIOR TO INSTALLATION,AND COORDINATE ELECTRICAL LOADS AND WIRING SCHEMATIC WITH THE ELECTRICAL CONTRACTOR. �,--r RETURN AIR/GRILLE 20.INSULATION AND DUCT MATERIALS SHALL HAVE A FLAME-SPREAD RATING OF 25 OR LESS AND A SMOKE-DEVELOPED RATING OF 50 OR LESS AS PER NFPA255. EXHAUST AIR/GRILLE 21.THE CONTRACTOR SHALL REPAIR OR REPLACE ANY OF THE OWNERS PROPERTY THAT IS DAMAGED WHILE UNDER CONSTRUCTION. RECEIVED W 22.CONTRACTOR IS TO OBTAIN ALL REQUIRED PERMITS AND INCLUDE THE COST IN HIS PROPOSAL. w MAY 2 ----------- SUPPLY AIR DUCT ,j 2 23.CONTRACTOR IS TO SUBMIT SUBMITTALS FOR ALL NEW ITEMS SHOWN ON SCHEDULES(INCLUDING CONTROLLERS),FOR ENGINEER APPROVAL,PRIOR TO ORDERING OF SAME. FALLS C17y OF TWIN ALLB --- RETURN AIR DUCT 24.ALL MATERIAL AND EQUIPMENT FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE FREE FROM DEFECTS,AND SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BUILDING DEPT. FROM DATE OF FINAL ACCEPTANCE BY THE OWNER OR HIS REPRESENTATIVE.SHOULD ANY TROUBLE DEVELOP DURING THIS PERIOD DUE TO FAULTY WORKMANSHIP,MATERIAL, LdJ OR EQUIPMENT,THE CONTRACTOR SHALL FURNISH ALL NECESSARY MATERIAL AND LABOR TO CORRECT THE PROBLEM WITHOUT COST TO THE OWNER. ®,J CANADA ----- EXHAUSTAIRDUCT 25."PROVIDE"ON DRAWINGS SHALL MEAN FURNISH AND INSTALL. rr OUTSIDE AIR DUCT 26. ALL ITEMS ARE NEW UNLESS NOTED OTHERWISE. 1 / v M AD AUTOMATIC DAMPER 27. ALL PIPING,DUCTWORK,LOUVERS,DIFFUSERS,AND GRILLES TO BE THE SIZE SHOWN ON DRAWINGS UNLESS OTHERWISE SPECIFIED BY ENGINEER. .. Coeur d'Alene s 28. WHEN REQUIRED MY IMC 307.2,307.2.1,OR 307.2.3,PROVIDE UL 508 CONDENSATE WATER-LEVEL DETECTION DEVICE THAT WILL SHUT OFF HVAC EQUIPMENT PRIOR I TO OVERFLOW OF CONDENSATE PAN OR RECEPTACLE DUE TO CONDENSATE DRAIN BLOCKAGE OR CONDENSATE PUMP FAILURE. 0 W� 29. INSTALL EXTRACTORS WITH MANUAL VOLUME DAMPERS WHERE DUCT BRANCHES FROM MAIN SUPPLY DUCT. r � Z es O� 30. CONTRACTOR TO COMPLY WITH NFPA STANDARD NO.90 AS APPLICABLE TO CONSTRUCTION AND INSTALLATION OF REQUIRED AIR DIFFUSERS,GRILLES AND REGISTERS. 3 �q/ REVISIONS''"Moscow ®W DOWNTOWN N 31. THERE SHALL BE NO FLEXIBLE DUCT CONNECTORS TO DIFFUSER OR GRILLES ON THIS PROJECT. Q DATE DESCRIPTION Lewiston 12 32. USE SCHEDULE 40 STEEL PIPE ON NATURAL GAS LINE TO FURNACES. PAINT NEW EXTERIOR EXPOSED GAS LINES WITH CORROSION RESISTIVE PAINT. RENAISSANCE 33. COORDINATE COLOR OF GRILLES,REGISTERS AND DIFFUSERS WITH THE GENERAL CONTRACTOR. Grangeville TWIN FALLS, ID a OO New Meadows y2 W es 7 O� Q Stanley St.Anthony BOISE " Arco Nampa Idaho Mm. Falls e Hom Pocatello 16 c0 0 hoshone Z 0 Jerome so p SHEET#: 0 sQi Twin s' r Falls Bu11ey 3 NEVADA UTAH v. 1 aF 4 NOTES: 1. RE:SHEET TO MT-1 FOR GENERAL NOTES,AND LEGEND. 2. PATCHING OF HOLES ARE BY THE MECHANICAL CONTRACTOR,AS z APPLICABLE,WHILE PAINTING,FINISHES AND COVERINGS TO WALLS,FLOORS AND CEILINGS SHALL BE BY THE GENERAL CONTRACTOR. KEY NOTES: (OiD TRANSITION FROM SUPPLY DUCTWORK DOWN TO NEW COILS. E PROVIDE FLEXIBLE CONNECTION ABOVE COILS. Fo7 y--E-- OO 02 PIPE,"GAS LINE LINE WITH SHUT OFF VALVE FROM PROVIDE INDIVIDUALI NG WSHUT Xp M EXHAUST FAN(E) OFF VALVE AND DIRT LEG AT EACH FURNACE. >w o rn n N N W ZI+-�Noo� N M ~ 03 PIPE PVC COOLING COIL AND PVC FURNACE CONDENSATE DRAIN O Q Lh .. Z ROOFTOP TO EXISTING DRAIN. O Z E m'LL O lL UNIT(E) 08 66 04 PROVIDE NEW 12"DIA.OUTSIDE AND EXHAUST AIR DUCTS WITH u Q O V 1(N) NEW MVD AND MOTORIZED DAMPER FOR HRV 1 A/1 B. 0 ' u CU(E) 2• 3"0 PVC VENT I�G(E) OS INSTALL NEW SCH.40 PVC VENT AND COMBUSTION AIR FROM 7tlItliSR0N1 O 3/4„(E)J r &FLUES(E) ,A FURNACE AND TERMINATE OUT THROUGH SIDE WALL TO 7tl8R1711816' Q 3/4"(Q— I ROOF TOP GAS DOWN TO METER#1 BUILDING EXTERIOR,NO CLOSER THAN 1 T HORIZONTALLY OR 3' •v3lm03w V pg C CU(q CU(E) EVAP. Q UNIT(E) FOR CONTINUATION SEE ABOVE ANY OSA INTAKE. (RE:M-2 DETAIL 5 AND M-3 FOR PIPE u COOLER DETAIL A THIS SHEET SIZES.) I T MIN. -I 10•MIN,—_.� 06 O6 PROVIDE INTAKE OR EXHAUST WALL VENT CAP WITH BIRD co G(q G(q G(q G(E) G(E) SCREEN.TERMINATE NO CLOSER THAN 10'HORIZONTALLY OR 3' 06 G(E) VERTICAL ABOVE CLEARANCE BETWEEN EXHAUST AND m 1/2"(q 06 02 O6 14 1 1/4"(q C3 } 1��(q 1 1/4"(E) 1"GAS(N) I VENTILATION TERMINATION. ► C m }� m 6'0 EXHAUST(q 12„0(N) 07 ROUTE 1/2'DRAIN LINE FROM HRV 1 A/1 B TO NEAREST DRAIN. Bin D W Z Z d I I I LOCATE UNIT AS HIGH AS POSSIBLE. t.7 LII� co (L 09 12'0(N) 09 1 08 ROUTE NEW 3/8'LIQUID AND 718"SUCTION ACR COPPER LINES Q 6"0 EXHAUST I 12"0(N)� I WITH 1 1/2"THICK ARMAFLEX ON SUCTION BETWEEN 03003 N111E1MGMe DUCT(q 04 I OPEN DUCTS.35 J APPLICABLE FURNACE AND CONDENSING UNIT.PROVIDE _ CFM EACH(E) WITH UV PROTECTIVE PAINT WHERE EX ( ) 1eCD 305 305 ®305 'rl 07 a q EXTERIOR. POSED TO CFM (N�1 O j�CFM 09 DOWN(E) E "� M N _ ROUTE NEW -'----- -----N----- - -- ------- CFM 09 (N 1 u 1( 120 CFM R 10"0 CD(E) 10"0 CD(E) 10"0 CD(E) 10"0 CD(E) 09 RO DUCTS,PIPING,VENTING,WIRING AND UNITS AS �- �- "O(N) - �---------- -- '�----- - �---- ---------c---QI D ou-- -------� --ti - ROUND - - '� CLIENT: PROJECT: CFM 100(N) 10"0 ON.(N) 12 0(N) 10"0 ON.(N)14"0(N)J I TO ON. 1 I I wl Q S OUZ f(E)�' q\ /�ON� `�'ROUNp�QZY f---------&---' DUC`f�Ej HIGH AS POSSIBLE.THESE ITEMS WILL BE PAINTED,BY THE J I 1 I 190 CFM OG�� DI UCT(E)190 CFM 190 CFM 190 CFM GENERAL CONTRACTOR,TO MATCH THE INTERIOR BUILDING 16"0(N) I I I I pl (N) I OO WHERE EXPOSED TO THE PUBLIC VIEW IN THE BANQUET AREAS. 12" 08 I I i MV (N)01-� 1 roll PROVIDE 15"HIGH MIN.RAISED RETURN AIR PLENUM UNDER SO 05 jl 100 rF I F6A/6B.THEN TRANSITION FROM 24'x1 5"H TO 28"x28"RG-1 G i 03 I I ® 01 CFM ^; RETURN GRILLE OPENING. (N 1 F I 10"0 CD(E)I Z 1 04 wl Z Z Z LLI 10 C6 CIS j N N I I 80 CFM @I 09 pi S'�P Q �fJ z O O Z I(N F6 5' SDI 16 RETURN GRILLE 01 �,n e� s �q, "Oh _ L' 1_k,Q AFF(N) I _ UP HIGH(E) o; '�C.0 W`Cl' 1 U Q O Q 5 ruKO IK Gv� y4 i TO EXISTINGIST 12"0 IN led Lr �✓ d' OvvZI��n,G I I SYSTEMSECHANICAL OT(q�l �ts�`'v"" S O Z L c I L I I I�EXHAUST 12"0(N) Z V) W I FAN(q i Z Ce O Z 1 6"(E) F-5 _ LLI lV� FURNACE(E) _] U � 6"(E) I I 1 1 16"0 1 I , (Nfj 10"0 ON. 09 10"*OD N. 10"0 ON.I I 6„(q i I U 310 -� -- ----------- - -- ---------- __ / 10'0 CD(q 10"0 CD(E) 10.0 CD(q Z 7� __--_-_�d• 10"0 J C 12"0 7 14„0: D 1 CFM (NIS (NIT Me f RouN6DDLTTES-' -RaUTJ6"ISU�YtFS-----------R-bTf lTiTc-rmT------ J 305 305 305EXHAUST 190 CFM 190 CFM 190 CFM = CFM CFM CFM ��� FAN(EU) a EXISTING WALL MTD. w ELECT.SPACE HEATER C1YP.OF 2). O Z J ca LL c `© Z 122'+ Z _ ON N w REVISIONS Q DATE DESCRIPTION u 3/4'GAS(E) N W SECOND FLOOR PLAN EXISTING&NEW HVAC 2"GAS(E) SCALE: 3/16"=1'-0" G(E) G(E) S E D� METER 1(q NEW UNIT CONTROL SEQUENCE OF OPERATION DETAIL A 1. FURNACE FAN SHALL OPERATE CONTINUOUSLY WHEN THERMOSTAT IS IN THE OCCUPIED CONTINUATION MODE AND SHALL CYCLE ON AND OFF BASED ON A CALL FOR HEATING OR COOLING INTHE UNOCCUPIED SED IN THE SCALE: NTS BANQUET AREA UNOCCUPIED MODEIAND SHALL DBE OPEN INOOR AND THEOCCUPIED MODE.XHAUST AIR DAMPERISHRV OFANS SHALL BE SHEET#: ON IN OCCUPIED MODE AND OFF IN UNOCCUPIED MODE,VIA INTERLOCK WITH FURNACE FRESH AIR BALANCE SCHEDULE FANAND OUTSIDE AND EXHAUST AIR DAMPER PROGRAMMABLE THERMOSTAT CONTROL F WIRING. SYSTEM OSAIN EXHAUST OUT F-5 685 CFM 685 CFM IN NIGHT SETBACK MODE,UNITS SHALL CONTROL TO THE UNOCCUPIED TEMPERATURE SET POINT AND THE OUTSIDE AND EXHAUST AIR DAMPERS SHALL BE CLOSED. PROVIDE 10 5 0 1 0 F-6A/6B 685 CFM 685 CFM 2-3 HOUR OVERRIDE OF UNOCCUPIED MODE AT EACH THERMOSTAT. SCALE IN FEET 2 OF 4 NAL F 2 3346 1p 1"MIN ON E BOTTOM ADJUSTABLE ELBOW $m N RINGS L O m I yy 11 M wmw inn O N MAIN DUCT >w o O1 N W Q'M Q Z LL j m N M O Np2 EmLL Uj Z W DIAMETER EQUAL n F-- m Q TO REQUIRED SUPPLY BRANCH DUCT 0 - fn DIAMETER HANGER RODS,WIRE OR AIRFLOW 7YItl15rtON1 STRAPS HANGER HANGER RODS,WIRE OR 'ItlURi011tli5, LOAD RATED 7tl01NtlH034f STRAPS HANGER FASTENERS SEAL ALL ' (TYP) AROUND m Q U) .� Q STRAP OR MVD(WHERE m BAND APPLICABLE) ► •tn 1"MIN ON TOP& W m m 6 BorroM aan Down x�xOxo� a 1/4 BRANCH DUCT STRAP OR BAND WIDTH(4"MIN) 25"TO 84"0 DUCT UP TO 24"0 DUCT MAIN DUCT LIF enmes�x CLIENT: PROJECT: NOTE: ALL HANGERS,RODS,WIRE,BANDS,SUPPORTS&HARDWARE TO BE SIZED FOR LOAD PER SMACNA HVAC DUCT CONSTRUCTION STANDARDS(LATEST EDITION). DO NOT EXCEED LOAD LIMITS. EQUAL TO SPECIFICATION NOTES: SEAL ALL REQUIRED BRANCH 1. MAXIMUM HANGER SPACING 12'. AROUND DUCT DIMENSIONS 0 w 2. UP TO 24"0 DUCT-1/4"ROD/1"x22 GA STRAP. Z Z Z 3. 25"TO 84"0 DUCT-TWO 3/8"RODS/TWO 1"x16 GA STRAPS. 2 4. STRAPS ARE GALVANIZED STEEL;RODS ARE UNCOATED STEEL. MVD(WHERE (� O O / Z APPLICABLE) � u � < oc O Z v1 DETAIL 1 DETAIL 2 w V) N Q ROUND DUCT HANGER DETAIL TYPICAL BRANCH TAKE—OFF DETAIL Z Z L`I Z O SCALE: NTS SCALE: NTS O I..I..I 1/2"FOAM INSULATION IN UNCONDITIONAL SPACE N J 18"MAX EXHAUST VENT ° " Q w _ O O TURNING VANES 00 as � SHEET METAL SCREWS ON 4" FIRE RESISTANT RUBBER DUCT CENTERS IMPREGNATED FABRIC 5" INTAKE VENT REVISIONS 1-1/2"POCKET SLIP a Q DATE DESCRIPTION 1"xl/8"BAND IRON FRONT VIEW —' SIDE VIEW NOTE: 1.PROVIDE MIN.10'OF HORIZONTAL OR 3' ------3"-4"(10"MAX) --I VERTICAL ABOVE CLEARANCE BETW EEN FLUE T OUTLET/INLET 20 GA STL AND VENTILATION INTAKE AIR. 20 GA STL 2.VENT PER MANUFACTURER'S INSTRUCTIONS. DETAIL 3 DETAIL 4 DETAIL 5 TYPICAL ELBOW DETAIL TYPICAL FLEXIBLE CONNECTION DETAIL MULTI UNIT SIDEWALL VENTING DETAIL SCALE: NTS SCALE: NTS SCALE: NTS SHEET#: M - 2 3 OF 4 CONDENSING UNIT SCHEDULE (MANUFACTURERS: BRYANT,CARRIER,TRANE,LENNOX,MCQUAY,YORK OR APPROVED EQUAL.) 55�oNALFyc G � SYMBOL DESCRIPTION ELEC MCA MOP RLA FLA COMP. COND.FAN FAN HP SENSIBLE CLG.BTUH SEER REFRIG. LINE SIZES REFRIG. WEIGHT REMARKS MFGR/MODEL p, 3 46 3/8"L. FURNISH W/COIL GUARD,LOW AMBIENT CONTROLS,CRANKCASE HEATER,EVAPORATOR BRYANT 165ANA036-B CU6A/6B CONDENSING UNIT 208-230/1/60 21.9 35A 16.7 1.1 1/6 29,700* 14.5 R410A 7/8„S 259 LBS FREEZE T-STAT,WINTER START CONTROL,FILTER DRIER,AND COMPRESSOR START ASSIST. OR APPROVED EQUAL OF s�7T F.MGC'VJ� "BTUH SENSIBLE CAPACITY AT 62 DEGREE WB/76 DEGREE DB ENTERING AIR TEMPERATURE AND 95 DEGREE DB OUTSIDE AIR TEMPERATURE. E ygg mn N O >WOc N � W QU- zm FURNACE SCHEDULE (MANUFACTURERS: BRYANT,CARRIER,TRANE,LENNOX,MCQUAY,YORK OR APPROVED EQUAL.) '0 _ ,N z SYMBOL DESCRIPTION BTUH HEATING CAP. PVC VENT& v�i 0 ;m'�' W Z TYPE CFM S.P. HP FLA MOCP ELEC. MIN AFUE WEIGHT 33 W (INPUT)/(OUTPUT) COMB.SIZE REMARKS MFGR MODEL CONDENSING GAS UP-FLOW FURNISH WITH ECM MOTOR,TWINNING KIT,AIR FILTER RACK&APPLICABLE BRYANT 355CAV042080 o O' F6A/6B 1,225 0.8" 0.5 7.7 15A 120/1/60 95.0% 80/74 182 LBS 2)2"0 FIRED FURNACE (FLOOR MOUNTED UNIT) TERMINATION KIT. PROVIDE CONDENSATE NEUTRALIZATION DRAIN KIT. OR APPROVED EQUAL ivivisp iyujinR0NI �T W lY3INV MW_1 TtlOINtlH73W G0-1 m U) m C] m m m EVAPORATOR COIL SCHEDULE (MANUFACTURERS: BRYANT,CARRIER,TRANE,LENNOX,MCQUAY,YORK,USA COIL&AIR OR APPROVED EQUAL.) 84III�DI^[� z z 0. 0 o a CFM BTUH SEN. S.P. WEIGHT SYMBOL DESCRIPTION WET COIL REMARKS CAPACITY" MFGR/MODEL `°"` °E`"1H61HC [ 7 EC6A/6B COOLING COIL 1,225 29,700' 0.17 37.5 LBS FURNISH WITH OPTIONAL TXV. BRYANT CAPVP3621 (OR APPROVED EQUAL) 'BTUH SENSIBLE CAPACITY AT 62 DEGREE WB/76 DEGREE DB ENTERING AIR TEMPERATURE AND 95 DEGREE DB OUTSIDE AIR TEMPERATURE. CLIENT: PROJECT: oa ZZ Z U z00 3: Z GRILLE®ISTER SCHEDULE (MANUFACTURERS: TITUS,METAL-AIRE,CARNES,KRUEGER,PRICE,TUTTLE&BAILEY,NAILER HART OR APPROVED EQUAL) U Q Q Q SYMBOL DESCRIPTION SIZE MATERIAL PATTERN INSTALLATION REMARKS MFGR/MODEL af O Z Ln RG-1 RETURN GRILLE 28"x28" STEEL SINGLE 35° WALL MOUNTED PROVIDE TRANSITION FROM GRILLE SIZE TO DUCT SIZE. TITUS 355RL L1J l/1 In Q DEFLECTION (OR APPROVED EQUAL) Z Z � O 7 EG-1 EXHAUST GRILLE 6"x6" STEEL SINGLE 35' DUCT MOUNTED PROVIDE TRANSITION FROM GRILLE SIZE TO DUCT SIZE. TITUS 355RL 0 LU DEFLECTION (OR APPROVED EQUAU U DIFFUSER SCHEDULE (MANUFACTURERS: TITUS,METAL-AIRE,CARNES,KRUEGER,PRICE,TUTTLE&BAILEY,NAILER HART OR APPROVED EQUAL) SYMBOL DESCRIPTION FACE SIZE MATERIAL PATTERN INSTALLATION REMARKS MFGR/MODEL CD-1 DUCT MOUNTED MATCH DUCT STEEL ADJUSTABLE DUCT MTD. MATCH DUCT SIZE OR NEXT LARGER SIZE. RE: M-1. TITUS TMRA SIZE OR LARGER ROUND (OR APPROVED EQUAL) Lu J 0 Lu HEAT RECOVERY VENTILATOR SCHEDULE (MANUFACTURERS: LIFEBREATH,DES CHAMPS/MAMMOTH,CARRIER,BRYANT,TRANE,LENNOX,YORK OR APPROVED EQUAL.) SYMBOL DESCRIPTION ELEC RATED AMPS HP zn S.P. WEIGHT REMARKS MFGR/MODEL HRV1A/1 B HEAT RECOVERY 120/1/60 7.9 2)1/4 8S OSA 0.4"0.4 255 LBS INCLUDE DUAL ALUMINUM CORES,MIN.81%EFFICIENCY,PSC 3-SPEED MOTORS,WASHABLE AIR FILTERS,HRV FAN CONTROL LIFEBREATH 850FD VENTILATOR 85 EXH. DEFROST,MICROPROCESSOR CONTROLS,&INTERLOCK RELAY. FANS TO RUN WHEN T-STAT IN OCCUPIED MODE. (OR APPROVED EQUAL) REVISIONS 0 DATE DESCRIPTION BALANCE REPORT IS REQUIRED SHEET#: M - 3 4 0F 4 KEY NOTES: Ol REMOVE EXISTING 4"SANITARY DOUBLE TEE AND PIPE WITH TWO NEW 4"SINGLE y\ONAL F TEES AND RELOCATE EXISTING 4"SANITARY SEWER LINE AS SHOWN. 346 N)�OF`v J INSTALLATION: 1.ALL WORK IS TO COMPLY WITH LOCAL REGULATIONS AND APPLICABLE PLUMBING CODE AND STANDARDS. EE 2.INSTALL PRODUCTS/EQUIPMENT IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN F$$8 INSTRUCTIONS AND IN THE LOCATIONS INDICATED.SEAL PIPING JOINTS IN ACCORDANCE w c iO m WITH MANUFACTURER'S RECOMMENDATIONS. x 3.MANUFACTURERS: w_ `n`n N N <O Pmro O F- PROVIDE PRODUCTS PRODUCED BY ONE OF THOSE LISTED ON SHEET P-2 SCHEDULE OR z u rn N o o N APPROVED EQUAL. u u o Z o�ZmLL 4.MATERIALS: Z n a` FF-- m Q PVC(OR ABS WHEN CONCEALED ABOVE CEILING)SCHEDULE 40 DWV PIPE AND FITTINGS: to ASTM D-2665 OR ASTM F-891(IF PERMITTED BY LOCAL CODES).PROVIDE FACTORY-FABRICATED FITTINGS OF THE SAME TYPE,MATERIALS,GRADE,CLASS AND TYIB38RON1 PRESSURE RATING INDICATED FOR EACH SERVICE AND PIPE SIZE. TY8f1J.0nuil 7Y0INVH08W 5.FLOOR AND ROOF DRAINS: a.INSTALL DRAINS AT LOW POINTS OF THE SURFACE AREAS TO BE DRAINED. ED y b.INSTALL FLASHING COLLAR OR FLANGE SO THAT NO LEAKAGE OCCURS BETWEEN DRAIN AND ADJOINING SURFACE. MAINTAIN INTEGRITY OF WATERPROOF MEMBRANES,WHERE ` T } m PENETRATED. ca 0] C1 NOTE: HORIZONTAL PIPING SHOWN IS IN c.POSITION DRAINS SO THAT THEY ARE READILY ACCESSIBLE AND EASY TO MAINTAIN. BJRI'JO�� Ix O U) 0- THE CEILING SPACE BETWEEN FLOORS. d.THE INSTALLER OF THE WASTE PIPING SYSTEMS SHALL ADVISE THE CONTRACTOR OF REQUIRED PROTECTION FOR THE WORK DURING THE REMAINDER OF THE rvo"EE CONSTRUCTION PERIOD,TO AVOID CLOGGING WITH CONSTRUCTION MATERIALS AND DEBRIS AND TO PREVENT DAMAGE FROM TRAFFIC AND OTHER CONSTRUCTION WORK. M-ST TEN CLEAN-OUT WC GENERAL NOTES: CLIENT: PROJECT: (N 1 CAP(E) 1 N) 3 ,. ... 1.VENT TERMINATIONS: 2"VENT(N) 3"(N) 3"VTR(N) WHEN REQUIRED BY LOCAL CODE OR SNOW CLOSURE IS LIKELY TO OCCUR,EACH VENT EXTENSION THROUGH A ROOF SHALL BE AT LEAST(3)INCHES IN DIAMETER.THE CHANGE IN DIAMETER SHALL BE MADE INSIDE THE BUILDING AT LEAST ONE(1)FOOT BELOW THE ROOF& MEN'S RESTROOM IS NEW TERMINATE NOT LESS THAN TWELVE 0 2)INCHES ABOVE THE ROOF OR AS REQUIRED BY THE Z z Z L1J ALL OTHER ROOMS ARE ADMINISTRATIVE AUTHORITY. V O 0 U q EXISTING. 2.SLOPE ALL GRAVITY DRAIN SEWERS 1/4'PER FOOT. 3,�(E) U Q O _IDS�I 2"(E) q��(E) i r(RU - 1 N) 4"(RQ U 3.CONTRACTOR SHALL FIELD VERIFY SITE SEWER PRIOR TO STARTING WORK.SHOULD SEWER BE - - -�r ;(E) 1 N) DIFFERENT FROM THAT SHOWN,ADVISE ENGINEER IMMEDIATELY. Ln 4.FLOOR CLEANOUTS SHALL BE INSTALLED WHERE SHOWN OR AS DIMENSIONED. W l~3"(E) 4"DOWN. 3"VTR(N) S.INDIVIDUAL SEWER AND VERTICAL VENT SIZES ARE NOT SHOWN FOR FIXTURES ON THIS PLAN. z Z LuO Z . I TO BASEMENT REFER TO FIXTURE SCHEDULE ON SHEET P-2 FOR SIZES OU 0 W 6.FOR APPROVED EQUAL STATUS,OTHER THAN MANUFACTURERS LISTED ON THE DRAWINGS, SUBMIT REQUEST TO MCCLURE ENGINEERING,INC.NO LATER THAN 2 DAYS PRIOR TO BID LAV E) I OPENING. / VENT UP 7.WITHIN 1 WEEK OF BID ACCEPTANCE THE CONTRACTOR SHALL SUBMIT SUBMITTALS TO MCCLURE ENGINEERING,INC.FOR REVIEW AND APPROVAL OF ALL SCHEDULE ITEMS ON SHEET 3„(� P-2. NO EQUIPMENT SHALL BE ORDERED UNTIL SUBMITTALS HAVE BEEN APPROVED. LAV(E) WC CL. -OUT 1 R);. CAP(E) RECONNECT 7 70 E Q 3"SEWERWER AN AND RELOCATE AS Z ___I NEEDED. LU f�_ LEGEND-PLUMBING >�7� a K, SYMBOL DESCRIPTION LuO ------------ COLD WATER(CM PIPING L J --------------- HOT WATER(HW)PIPING Ln U- HWR HOT WATER RETURN PIPING z 122 t G NATURAL GAS PIPING O --------- WASTE PIPING Lu U Z Lu ----------------- VENT PIPING N -----CD•---- CONDENSATE DRAIN FCO OR ® FLOOR CLEAN OUT REVISIONS Q DATE T DESCRIPTION WCO OR I WALL CLEAN OUT TWO-WAY CLEAN OUT W N ® FLOOR DRAIN NEW WASTE&VENT ® FLOOR SINK SECOND FLOOR PLAN L O HUB DRAIN SCALE: 3/16"=1'-0" 5 COTG OR ® CLEAN OUT TO GRADE -><- GATE VALVE CHECK VALVE AFF ABOVE FINISHED FLOOR , SHEET#: (E) EXISTING (N) NEW P— (R) REPLACE WITH NEW 10 5 O 10 (RU RELOCATED SCALE IN FEET (VTR) VENT THROUGH ROOF OF INSTALLATION: INSTALLATION: (ALSO SEE SPECIFICATIONS MANUAL.)(CONTINUED) KEY NOTES: 1. INSTALL WATER DISTRIBUTION PIPING IN ACCORDANCE WITH RECOGNIZED INDUSTRY 9.WATER HAMMER ARRESTERS: INSTALL IN UPRIGHT POSITION,IN PLUMBING FIXTURE SCHEDULE 0 SHUT-OFF VALVES BELOW FLOOR,IN 1 ST FLOOR CEILING PRACTICES WHICH WILL ACHIEVE PERMANENTLY LEAK PROOF PIPING SYSTEMS,CAPABLE OF LOCATIONS AND SIZES IN ACCORDANCE WITH PDI STANDARD WH-201, MANUFACTURER/ HOT COLD SPACE IN RESTROOM HW AND CW MAIN LINES PERFORMING EACH INDICATED SERVICE WITHOUT PIPING FAILURE. INSTALL EACH RUN WITH AND ELSEWHERE ASS , .INDICATED. SYMBOL DESCRIPTION TRIM&DETAIL _ MINIMUM JOINTS AND COUPLINGS,BUT WITH ADEQUATE AND ACCESSIBLE UNIONS FOR MODEL" WATER WATER WASTE VENT REMARKS 02 PROVIDE WATER HAMMER ARRESTERS OF SIZE TO MATCH e�X()NAL DISASSEMBLY AND MAINTENANCE/REPLACEMENT OF VALVES AND EQUIPMENT. REDUCE SIZES 10.INSTALL PRODUCTS/EQUIPMENT IN ACCORDANCE WITH THE FLUSH VALVE SERVED. WHERE INDICATED,USING REDUCING FITTINGS. ALIGN PIPING ACCURATELY AT CONNECTIONS, MANUFACTURER'S WRITTEN INSTRUCTIONS AND IN THE LOCATIONS WCO WALL CLEAN OUT MIFAB C1430 RE: P-1 FOR SIZES N/A N/A N/A N/A GASKET SEAL/BRONZE PLUG. MOUNT 18"AFF WITHIN 1/16"MISALIGNMENT TOLERANCE. INDICATED.SEAL PIPING JOINTS IN ACCORDANCE WITH MANUFACTURER'S 1 AND PROVIDE STAINLESS STEEL COVER. ct RECOMMENDATIONS. 03 LOCATE EXHAUST TERMINATION AT MINIMUM OF 3'-0" C ABOVE OR 10'-0"HORIZONTALLY FROM ANY INTAKE 2.INSTALL PIPING,INCLUDING MAINS,BRANCHES,RISERS,AND RUN-OUTS,WITH SUFFICIENT MXV SET FOR I 10'ONE F.AT RESTROOM M.HAND SINKS AND KITCHEN VENTILATION AIR. 46 OFFSETS TO ALLOW FOR FREE EXPANSION AND CONTRACTION,AND SUFFICIENT TO PREVENT 11.INSULATE DOMESTIC HOT WATER,HOT WATER RETURN,AND COLD 1 MIXING VALVE LEONARD 210 N/A 3/4" 3/4" N/A N/A PROVIDE ONE UNIT PER ROOM. RUN A i C LINE TO ALL LEAKS AND OVER-STRESSING OF PIPING SYSTEM. WATER LINES WITH INSULATION BY OWENS CORNING FIBERGLASS,CERTAIN FIXTURES. FURNISH WITH INTERNAL CHECK VALVES. /'� ,- _ „,,,,•", TEED,MANVILLE,ARMSTRONG,IMCOA OR APPROVED EQUAL WITH A FIRE LAy LAVATORY ADA AMERICAN STANDARD PROVIDE WITH AMERICAN STANDARD 0059.020 KNEE TI•F, COYJQ 3.STERILIZATION:AT COMPLETION OF WATER SERVICE LINE INSTALLATION,FLUSH AND STERILIZE SMOKE HAZARD RATING OF 25/50/150 PER ASTM STANDARD E-84. 1 COMPLIANT "COMRADE"0124.024 5402.172H 1/2" i/2'• 2" 1 1/2 GUARD. v NI IN CONFORMANCE WITH AWWA C-601,TO SATISFACTION OF LOCAL AUTHORITIES HAVING INSULATION TO BE 1"THICK ON HOT WATER AND 1/2"THICK ON COLD WALL MOUNTED JURISDICTION. WATER. /-U-\ AMERICAN STANDARD 1" 3" URINAL SLOAN ROYAL 186 N/A 2" 1.0 GALLON PER FLUSH ii6H�Hd6-- 4.SHUT-OFF VALVES: INSTALL ON INLET OF EACH PLUMBING EQUIPMENT ITEM,AND ON INLET OF 1 'TRIMBROOK"6561.017 $ EACH PLUMBING FIXTURE,AND ELSEWHERE AS INDICATED. GENERAL NOTES: WATER CLOSET ADA OS IN BASEMENT,RECONNECT AND PIPE IN EXISTING HOT 1- WC AMERICAN STANDARD CHURCH 5321.112 y c'O 1O COMPLIANT N/A 1 1/4" 4" 2" 1.6 GALLON PER FLUSH,FLUSH VALVE,FLOOR MOUNTED. WATER RECIRCULATION PUMP WITH 3/4"HWR LINE. �u 5. INSTALL BACKFLOW PREVENTERS WHERE REQUIRED BY APPLICABLE PLUMBING CODE. LOCATE IN 1.SEAL BETWEEN WALLS&PLUMBING FIXTURES PER REQUIREMENTS OF THE 1 FLOOR MOUNTED 3461.160 SLOAN ROYAL I I I INSTALL NEW TIME CLOCK ON PUMP TO TURN PUMP OFF 5 p $ SERVICEABLE LOCATION AND AS REQUIRED BY LOCAL CODE. HEALTH DISTRICT AND PLUMBING CODE. DURING ALL UNOCCUPIED HOURS.VERIFY PUMP ui 07°°c m o C) MATERIALS: >wo ern N N W•OR APPROVED EQUAL.APPROVED MANUFACTURERS: 1)FIXTURES: AMERICAN STANDARD,CRANE,KOHLER,ELJER,ZURN,TOTO,GERBER;2)FIXTURE SEATS: 8EMI5,BENEKE,CHURCH SEAT,OLSONITE,STANDARD, OPERATION AND REPLACE IF NEEDED. 2. COLD AND HOT WATER SUPPLY PIPING SIZES ARE NOT SHOWN FOR KOHLER,TOTO;3)FIXTURE TRIM:AMERICAN STANDARD,CHICHAGO FAUCET,CRANE,ELKAY,ZURN,KOHLER,SLOAN,MOEN,MCGUIRE,T&S BRASS,DELANY:4)MIXING VALVES: LEONARD,POWERS,SLOAN, Z LL r6 m N ~ 6. DOMESTIC COLD,AND HOT WATER PIPING TO BE COPPER TUBE OF SIZES INDICATED. FIXTURES ON THIS PLAN. RE: P-2 FIXTURE SCHEDULE FOR PIPE SIZES. SYMMONS,ACORN,WATTS. 6 N M Z a.WALL THICKNESS:TYPE L,HARD-DRAWN TEMPER(UNLESS OTHERWISE INDICATED). 3. CONTRACTOR TO VERIFY STATIC WATER SUPPLY PRESSURE.IF PRESSURE n N z m'LL o O b. FITTINGS:WROUGHT-COPPER,SOLDER JOINTS. EXCEEDS 80 PSI,SUPPLY AND INSTALL APPROVED PRESSURE REDUCING a H m Q VALVE. 7.SHUT-OFF VALVES:(INSTALLERS CHOICE WHERE MORE THAN ONE TYPE(INDICATED) rn 4. FOR APPROVED EQUAL STATUS,OTHER THAN MANUFACTURERS LISTED ON a. 1"AND SMALLER: GATE VALVES. THE DRAWINGS,SUBMIT REQUEST TO MtCLURE ENGINEERING,INC.NO TY1S18f10Ni' b. 1"AND SMALLER: BALL VALVES. LATER THAN 2 DAYS PRIOR TO BID OPENING. 7YBlliORtlJ.B C. 1-1/4"AND LARGER: BALL VALVES. 7YOINYHOBN S.WITHIN 1 WEEK OF BID ACCEPTANCE THE CONTRACTOR SHALL SUBMIT G BACKFLOW PREVENTERS: SUBMITTALS TO McCLURE ENGINEERING,INC.FOR REVIEW AND APPROVAL WATER CALCULATION TABLE 4 OF ALL SCHEDULE ITEMS ON SHEET P-2. NO EQUIPMENT SHALL BE ti Ci 8. MANUFACTURER: SUBJECT TO COMPLIANCE WITH REQUIREMENTS,WHEN REQUIRED,PROVIDE ORDERED UNTIL SUBMITTALS HAVE BEEN APPROVED. K > 4] AVAILABLE PRESSURE(PER PRESSURE READING RISER.) 70 PSI y to BACKFLOW PREVENTERS OF ONE OF THE FOLLOWING: } 6."PROVIDE"REFERENCE SHALL MEAN TO FURNISH AND TO INSTALL. } } m a.CLA-VAL CO. tr m 0] b.HERSEY PRODUCTS,INC. 9 � C.LAWLER,ITT FLUID HANDLING DIV. BACKFLOW PREVENTER LOSS 10 P51 BAR W I� Yd� � uZi a d.WATTS REGULATOR CO. STATIC PRESSURE LOSS(EL 10'-0"x0.43) 10.3 PSI 4 e.FEBCO MIN ALLOWABLE PRESSURE LAST FIXTURE 124.7PSII TOTAL PRESSURE AVAILABLE DISTANCE TO LAST FIXTURE EQUIVALENT DISTANCE IN FEET CLIENT: PROJECT:ALLOWABLE PRESSURE LOSS/100 FT(TOTAL PRESSUREx100')/(EQUIVALENT DISTANCE) TOTAL FIXTURES QUANTITY F.U.PER TOTAL (EXISTING&NEW) DEVICE F.U. 0<} LI.J LAVS,BAR&HAND SINKS 10 2 20 z Z Z U 00 WATER CLOSETS 8 10 80 Z - - Z 3 COMPARTMENT SINK 1 1.5 1.5 > U Q O D 0� �-- cn MOP SINKS 1 4 4 > 0 Z (n OS DISHWASHER 1 1.5 1.5 LLJu Ln V) Q Z NOTE: HORIZONTAL PIPING SHOWN IS IN O 0�f O Z THE CEILING SPACE BETWEEN FLOORS. URINALS 3 5 15 U ® W HOSE BIBBS' 1 2.5 2.5 L.L. 'EACH ADDITIONAL 1 1 1 02 TOTAL FIXTURE UNITS 125.5 F.U. TOTAL WATER REQUIRED 73 GPM (N 1 7 [ BUILDING HAS EXISTING 2"WATER MAIN LINE. z PROVIDE 12"x6"SIGHT PROOF DOOR TRANSFER GRILLE EQUAL TO TITUS T-700L, 1 1/4"(N) a MEWS RESTROOM IS NEW LEGEND-PLUMBING 1 N) ALL OTHER ROOMS ARE W 1/2^ry) I MEN 1 ry) EXISTING. Ol SYMBOL DESCRIPTION < O N 11/4"(q I 1„(N) U 02 ��yj6, _ 1 ------------- COLD WATER(CW)PIPING �,-- rp.I 1,(N) ---------------- HOT WATER(HW)PIPING CV✓(E7Jl 1/2" 1 1/2 CW(N) 01 w HWR HOT WATER RETURN PIPING ��ST JD (E) 2"CW(E)UP FROM BASEMENT z FAN(E) 3/4'(E) 6� 1 1/4"HW(E)UP FROM BASEMENT z Ol 1 1/2 (N) 3/4"HWR(E)UP FROM BASEMENT G NATURAL GAS PIPING 0 1/2„(E) u LA V E U 02 „ ---------- WASTE PIPING WC I L1J I Rk ------ VENT PIPING (N 1 > 11/4 j ----•CD----- CONDENSATE DRAIN �g (N)J� FCO OR ® FLOOR CLEAN OUT REVISIONS 3/4" (E) Q DATE I DESCRIPTION EXHAUST WCO OR WALL CLEAN OUT ® REMOVED EXHAUST& F (E) HEATER FROM REST TWO-WAY CLEAN OUT ROOM PLUMBING PLANS. RE:TO M-1 ® FLOOR DRAIN MECHANICAL SHEET. EXISTING WALL MTD. DAB/JAM 5.24.2013 ELECT.SPACE HEATER ® FLOOR SINK (TYP.OF 2). OHUB DRAIN COTG OR ® CLEAN OUT TO GRADE ->o- GATE VALVE - H' CHECK VALVE AFF ABOVE FINISHED FLOOR SHEET#: (E) EXISTING(N) NEW /� R ��� ■ W L (R) REPLACE WITH NEW S E 10 5 0 10 (RQ RELOCATED NEW WATER SCALE IN FEET (VTR) VENT THROUGH ROOF 2 OF 2 SECOND FLOOR PLAN SCALE: 3/16"=V-0"