Loading...
HomeMy WebLinkAbout23-3152 1751 Elizabeth Blvd Remodel-City Approved Plans OF TMNvMLIS �INYFAUfj City of Twin Falls �0 � General Inspection Notes �0ERVtN0 SERV►NG UP) a) NOTE: This is not a complete list and is not inclusive of all construction methods, materials or practices. These checklists are intended to serve as a guide for the items that cause the most issues during inspections and promote +=, consistency in the application of the codes & standard practices. Compliance with all the provisions of applicable codes shall be required. O The information in the checklists is not, or was it ever intended to be, all inclusive. It does not include all code or individual plan requirements. It is intended to reflect local policies, procedures & practices within the City of Twin Falls. These checklists do not waive any specific code requirements not listed or allow for the decrease in the requirements of an engineered design. It also does not add requirements where the minimum of the code has been met. Z This page and all approved plans, associated documents, revisions & changes to the plans must be maintained on site and available for review at all times. FIRE BUILDING FINAL INSPECTION INFORMATION O Fire Alarm Inspection: Footing/Foundation Inspection: COMMERCIAL OCCUPANCY • * Fire alarm plans must be approved by the State Fire Marshal's office or if applicable the Twin Falls * All re-bar must be tied in place at time of inspection. Fire Marshal prior to installation and inspection. * All hold down anchors installed properly. Final inspections are required by multiple City Departments/Inspectors prior t0 * Fire alarm system must be wired to call out from a land line, or with a cell dialer. (Voice over IP is not allowed). Shear Inspection: getting your Certificate of Occupancy. * Fire alarm system must be live and capable of calling the Twin Falls Dispatch Center on the day of * All hold downs must be installed per approved plans and manufacturers installation guide. testing. * Fasteners should not be overdriven and shiners should be removed and/or replaced. Make sure to have the approved set of plans and inspection card on site for all inspections. * Install the correct type of fastener at the correct spacing. Fire Sprinkler Inspection: If you have Special Inspections: Once the required special inspections have been completed a final * Fire sprinkler plans must be approved by the State Fire Marshal's office prior to installation and Framing Inspection: report needs to be submitted to the building department certifying corrections of any discrepancies inspection. Underground fire sprinkler line must be inspected by the Twin Falls Fire Department prior * Accessibility standards are in compliance. (ICC A117.1-2009) noted in the special inspection reports.This final report can be submitted any time before requesting [ ^ to be covered. * Required load paths to footing for all load points are installed. occupancy. �+ * Pipe or hose used for flushing the underground sprinkler line must be secure, incapable of * Stair rise and treads must meet code requirements. * Required Site Work inspections may be requested and completed as the work is done or as required movement, and is deemed safe by the inspector. *Min rise 4", Max rise 7", Max tread 11" by the specific department by contact the following: * Rough to cover inspection and hydro testing must be completed before covering or tenting the *Min nosing is 3/4", Max nosing is 1 1/4" and cannot differ in length by more than 3/8" above ground fire sprinkler system. * Provide required up-lift protection for all trusses. - Planning&Zoning (parking and landscaping) Planner-208-735-7270 or Office-208-735-7267 Kitchen Hood Inspections: Final Inspection: - Engineering (Retention, curb, gutter, sidewalk, drive approaches) * Fire suppression system must be installed and ready for trip test (trip link, balloons, etc.) prior to * Landings to meet minimum code requirements. (Doors 1010.1.6, Ramps 1012.6, Stairs 1011.6) Lab inspection line 208-735-3446 inspection. * Accessibility Standards are in compliance.(ICC A117.1-2009) -Street Department (road cuts) * Kitchen hood must be wired to initiate the fire alarm upon activation of the fire suppression system. * Egress door sign-age is posted and correct verbiage is used. Office- 208-736-2226 (The only exception to this is if the building does not require a fire alarm to be installed) * "DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED" * All electrical outlets, lighting, and appliances under the kitchen hood must shut down upon *Correct hardware has been installed on all doors. * When you are ready for any Fire Department inspections please call (extinguishers, activation of the fire suppression system. *Panic hardware is installed where required. fire/alarm/sprinkler systems): * Main gas valve must be installed and must shut down upon activation of the fire suppression *Accessible hardware is installed where required. Fire Inspection Line-208-735-7338 system. * Handrails shall be installed where required. * Exhaust fan must be capable of running continuously upon activation of the fire suppression * Stairways shall have handrails on each side. * When you are ready for a building final inspection on the structure: system. * All racking and shelving to be in place. Make sure you have the final inspections on the plumbing, electrical, and mechanical work. * Make up air must be capable of running continuously upon activation of the fire suppression system. * All Exit signs are field verified. (must be visible—nothing can block the line of sight) Call the building inspection line 208-735-7333 * Maximum Occupancy signs posted where required. All departments will be notified by this office to go do their final inspection. Final Inspection: * Special Inspection reports and balance reports need to be received by our office. * Address must be posted as outlined on the approved set of plans or previously approved by the If there is an elevator in the building please contact the Division of Building Safety at the following link Twin Falls Fire Marshal. PLANNING &ZONING for any permits/inspections: http://dbs.idaho.gov/programs/industrial/fagEL.html I ENGINEERING Landscaping: Once ALL the departments have signed the Certificate of Occupancy the Building Official will sign and * Our code allows for us to issue a TCO with landscaping incomplete; however, we cannot extend the then it will be ready to be picked-up or emailed. (All In order to streamline and eliminate confusion in regards to the engineering department commercial TCO beyond the current planting season.This means that we will work with the applicant on a permit inspections,the following will need to be inspected prior to signing the Certificate of definitive date of their choosing, but not typically beyond 2-3 months. If you need a Temporary Certificate of Occupancy there is a $1,000 refundable deposit required. All Occupancy. All inspections will be completed using the City of Twin Falls approved (stamped) plans. departments are required to sign and give a list of outstanding issues. Once the temporary is all signed Trash Enclosures: &the list made you will need to come in and sign stating you know what those issue are, that you will Storm Water Facility Inspections: (3 phases) * Trash enclosures should be finished before a final inspection is requested,this includes the front have them completed by the specified time, and will call for inspection as those items are completed. * Inspection of excavation, including dimensions and geotextile fabric. All adjoining trenches leading gate on the enclosure. Per our code, we cannot issue a TCO if this item is not completed. It is up to each department to determine if you meet their qualification for temporary occupancy. to storm water facilities also need to be excavated and inspected. * Inspection of storm drain pipes (per plans) need to be in place (not covered)for visual inspection. Note: If a building was originally done as a shell, the shell building permit is required to be finaled The drain rock must meet ISPWC section 801 Drain Rock requirements. All pipe connections to storm prior the tenant improvement permits can be finaled. In addition, if Temporary Occupancy is needed water facilities must be completed. Please have Address posted on site for all I there will be $1,000 refundable deposit for each permit. * Inspection of completed storm water facilities with the above referenced drain rock and geotextile fabric showing proper cover and overlap. Inspections. • Site Inspections: Please have a printed color copy of City * Verify that the parking lot layout (design) &striping matches the plans * Verify that the parking lot surface is an approved "hard" surface Approved Plans & Inspection Cards on site for * Verify that there is ADA compliant access from the Right-of-Way(ROW)to the building envelope all inspections. Right-Of-Way Inspections. * Verify driveway approach widths & locations according to plans * Verify ADA compliance of Curb/Gutter, Sidewalks, and Sidewalk/Driveway combinations O Verify ROW connections to other Agencies/Entities meet's ADA tolerances CITY APPROVED PLANS Flood Plain Inspections: * Verify flood plain location and compare plans to the site Reviewed for Code Compliance * Verify the commercial buildings are one foot above base flood elevation PLANS MUST BE ON JOB SITE When ready for inspection please call the Engineering inspection line at (208) 735-3446 for same day inspections call before 7:30 am. Having these inspections approved when the work has been FOR ALL INSPECTIONS • completed will ensure the Certificate of Occupancy is issued in a timely manner. __J 2018 IBC Section 105.4 Validity of Permit: The issuance or granting of a permit shall not be a permit for, or approval of, any violation of any of the provisions of this code or of any other ordinances of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the building official from requiring the correction of errors in the construction documents and other data. The building official is authorized to prevent occupancy or use of a structure where in violation of this code or of any other ordinance of this jurisdiction. P A n O_ 1 of :�q LICENSED P CHITECT A MODERNIZATION FOR: ARE85]OB saT-E aAIO E-STREET COMMUNITY CENTERPLAN A 128/2023 1751 ELIZABETH BLVD, TWIN FALLS, ID Based on20 8NALYSIS Editionofl.B.0 �- Architect of Record Laughlin Ricks Architecture,L.L.C. SHEET INDEX Engineer: SEE DESIGN TEAM THIS SHEET N Sheet Number Sheet Name GENERAL NOTES: w 1. ALL WORK SHALL MEET CURRENT ADOPTED STATE,LOCAL CODES,ORDINANCES,&2018 IBC Job Address: 1751 ELIZABETH BLVD,TWIN FALLS,ID C, AO-0 TITLE SHEET 2. ALL MECHANICAL,ELECTRICAL,&PLUMBING WORK SHALL MEET ALL CURRENT APPLICABLE O AO-1 CODE REQUIREMENTS STATE&LOCAL CODES. Y AO-2 CODE REQUIREMENTS 3. ALL UTILITIES SHALL BE PROPERLY IDENTIFIED&LOCATED BEFORE WORK BEGINS ON Legal Description: w AO-3 EXIT PLAN PROJECT. Occupancy Classification: A-3,E Occupant Load Per Area: SEE OCCUPANCY PLANS,A04 AO-4 OCCUPANCY ANALYSIS 4. CONTRACTOR SHALL VERIFY ALL CONDITIONS&DIMENSIONS AT THE JOB SITE&NOTIFY THE EXERCISE&DAYCARE A1-0 SITE PLAN ARCHITECT OF ANY DIMENSIONAL ERRORS,OMISSIONS,OR DISCREPANCIES BEFORE Occupancy Use: BEGINING OR FABRICATING ANY WORK. A1-2 POSSIBLE ASBESTOS AREA PLAN o Al-1 DEMO FLOOR PLAN 5. DO NOT SCALE DRAWINGS. A2-1 OVERALL NEW FLOOR PLAN 6. ALL DOOR HANDLES SHALL BE LEVER TYPE,ALL DOOR HARDWARE SHALL BE A.D.A Allowable Stories Per Code: Provided: 1 (IBC Table 505.4) Total: 2aa A2-2 ENLARGED NEW FLOOR PLAN COMPLIANTAS PER CURRENTANSI 117.1 IREOLIRED A2-3 ENLARGED NEW FLOOR PLAN 7. AT MAIN ENTRANCE DOOR SHALL HAVE SINGLE ACTION LOCKING DEVICE W OR SIGNED"THIS Floor Area: Basement: v: TOTAL+9•+o'ssc F Exits Required: Basement: 1st: s DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." MODIFI :65S SF A7-0 DEMO CEILING Mezzanine: 3rd: Total:TDTAL ED+s.+3OF SF 2Dd: 3rd: 4m: A7-1 NEW CEILING LQ A8-0 INTERIOR ELEVATIONS Total Required Exits Per Occupant Load: 2 (IBC Table 1006.3.2) TWIN FALLS FIRE DEPARTMENT NOTES: A9-0 DOOR SCHEDULE&TYPES Actual furthest travel distance to exit: 86' IBC Table 1017.2&1006.2.1 A9-1 FINISH PLAN 1. DEFERIT RED SUB ITTALSRESPO SQUAREDIBILITY BY HE FIRE DEPARAL TMENT ENHAVEOR BEEN THAT ALL ( ) DEFERRED SUBMITTALS REQUIRED TI THE FIRE DEPARTMENT HAVE BEEN APPROVED BY Al 0-0 DETAILS-CASEWORK&ROOF THE STATE PRIOR TO THE INSTALLATION OF A FIRE ALARM AND/OR FIRE SPRINKLER Penetrations?Show Approved Listed Products on Plans: N/A MP0-1 MECHANICAL&PLUMBING SPECIFICATIONS SYSTEM.IT SHALL ALSO BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THAT ALL APPROPRIATE TESTING AND/OR INSPECTIONS HAVE BEEN PERFORMED MP1-0 DEMOLITION FLOOR PLAN BEFORE COVERING OR CALLING FORA FINAL INSPECTION. Type Of Construction: VB Allowable Building Height: (E)IEBC 1011.5.2 ' MP1-1 MECHANICAUPLUMBING FLOOR PLAN Seismic Design Category: Q Allowable Area Calc's: (E) MP2-1 MECH/PLUMB SCHEDULES&DETAILS EO.0 ELECTRICAL SYMBOLS&DETAILS Automatic Sprinkler System: Yes: No: 0 (IBC Table 506.2) EO.1 EXISTING OVERALL ELECTRIC PLAN E1.0 AREA A-LIGHTING PLAN Maximum Floor Area Allowed: (E)1EBc 1011.5.z Exit Signs: Yes: X No: 0 LL E1.1 AREA A-POWER/SYSTEMS PLAN Z o Special Inspections Required? Yes: No: X Emergency Lights: Yes: x No: Z E1.2 AREA B-ELECTRICAL PLANS E2.0 POWER RISER&SCHEDULES Firewalls Required? Yes: No: X Fire Extinguishers Shown: Yes: x No: LL 1 of 1 KITCHEN EQUIPMENT (Specify Type&Rating) (IFC Section 906) Q z N_ (— Occupancy Separation Use? Yes: No: x Fire Hydrant Locations Shown: Yes: x No: o W Z F m W Areas of Refuge Required? Yes: No: x Vestibule Required: Yes: (E) No: W = 2 DESIGN TEAM (IBC Section 1009.2,3,4) 0 W m IY W STRUCTURAL:BOULANT ENGINEERING Area Separation Required? Yes: No: x Classified Areas? Yes: No: X O ~ CONTACT:MATT BOULANT 2 matt@boulanteng.com _ TABLE 508.4 (Show on plans&Show Areas) 208421-7218 REQUIRED SEPARATION OF OCCUPANCIES(HOURS) Q W Fire Resistance Ratings of BLDG Elements: 0 (IBC Table 601) ELECTRICAL:PAYNE ENGINEERING B°,F-1, CONTACT:SHAWN MEADOR OCCUPANCY A,E I-1°,1-3,14 1-2 R F-2,S-2°,U M,S-1 H-1 H-2 H-3,H4 H-5 (Specify Rating) sm.payneeng@gmail.com 208-232-4439 S NS S NS S NS S NS S NS S NS S NS S NS S NS S NS Minimum Roof Class: c (IBC Table 1505.1) Exterior Wall O enin S: NO LIMIT IBC 705.8 MECHANICAL&PLUMBING:ENGINEERED SYSTEMS ASSOCIATES A E Fire Doors: N/A (IBC Table 716.1.2) Fire Alarm System: YES @ E OCCUPANCY (IBC,907.2) CONTACT:DAVE HANSEN dave@engsystems.com 208-233-0501 "^ w _ " 8 M1��°"�----°•—"m= Fire Flow and Duration: Corridor Width: 44" (IBC Table 1020.2) TABLE 508.4 Rated Structural Frame: Yes: No: x Rated Corridors: Yes: No: x L� 1A =1'0" (Roof Supports Only) (IBC Section 1020.1) Rated Bearing Walls-Exterior: Yes: No: x Rated Bearing Walls-Interior: Yes:_No: x V ABBREVIATIONS Rated Nonbearing Walls-Exterior: Yes: No: x Rated Bearing Walls-Interior: Yes: No: x 4� by (>30'Fire Separation) (Roof Supports Only) Rated Nonbearing Walls-Exterior: Yes:_ No: x Rated Nonbearing Walls-Interior: Yes: 1 x AC ACOUSTICAL CEILING DIA DIAMETER GYP BD GYPSUM BOARD PL PLATE,PLASTIC LAMINATE T THREAD S� �y AD ADJUSTABLE-ADJACENT DIM DIMENSION HB HOSE BIB P-LAM PLASTIC LAMINATE TBB TILE BACKER BOARD (10'-30'Fire Separation) No: cd v AFF ABOVE FINISH FLOOR DF DRINKING FOUNTAIN HC HANDICAPPED PLWD PLYWOOD T&G TONGUE AND GROOVE o AL ALUMINUM DP DEEP HDR HEADER PNL PANEL TO TO OF Rated Floor Construction: Yes: No: x Rated Roof Construction: Yes: No: x ALT ALTERNATE DR DOOR HIM HOLLOW METAL PORC.TILE PORCELAIN TILE TOW TOP OF WALL N 2�o ANOD ANODIZED DS DOWNSPOUT HORIZ HORIZONTAL PR PAIR TPD TOILET PAPER DISPENSER AP ACOUSTICAL WALL PANEL DWG DRAWING HT HEIGHT PSF POUNDS PER SQUARE FOOT TSCD TOILET SEAT COVER DISPENSER Lighting Layout and COM Check? Yes:_ No: x t—il 3 AP APPROXIMATE E EAST HVAC HEATING/VENTILATING/ PSI POUNDS PER SQUARE INCH TT TIRE TREAD ARCH ARCHITECT(-URAL) (E) EXISTING AIR CONDITIONING PT PAINT,PRESSURE TREATED TYP TYPICAL rl Comments: N AW ACOUSTICAL WALL EA EACH ILO IN LIEU OF PTO PAPER TOWEL DISPENSER UNO UNLESS NOTED OTHERWISE AW F ACOUSTICAL WALL FABRIC EJ EXPANSION JOINT INSUL INSULATION QT QUARTZ TILE U/S UNDERSIDE w '� BLDG BUILDING EL ELEVATION INT INTERIOR R RISER,RADIUS VB VAPOR BARRIER CITY APPROVED PLANS x" > BM BEAM ELEC ECLECTRIC(-AL) JNT JOINT IRS RESILIENT BASE VCT VINYL COMPOSITION TILE Boo BOTTOM OF DECK EP ENAMEL PAINT KD KNOCK DOWN RE) ROOF DRAIN VERT VERTICAL d BOT BOTTOM EQ EQUAL LAV LAVATORY RO ROUGH OPENING VGF VINYL GYM FLOORING Reviewer Code Compliance M BTWN BETWEEN EW EACH WAY MCFP MULTI-COLORED FINISH RR RESTROOM VIF VINYL INDUSTRIAL FLOORING M CB CATCH BASIN EXG EXISTING PAINT SYSTEM RSF RUBBER SHEET FLOORING VR VAPOR RETARDER PLANS MUST BE ON JOB SITE CST CABINET EXP EXPANSION Moo MEDIUM DENSITY S SOUTH VT VINYL TILE th CG CORNER GUARD EXT EXTERIOR OVERLAY PLYWOOD SC SOLID CORE VWF VINYL WALL FABRIC PLAN ANALYSIS FOR ALL INSPECTIONS cJ CONTROLJOINT FA FIRE ALARM MECH MECHANIC(-AL) SCU STRUCTURAL CLAY UNIT W WEST CL CENTERLINE FD FLOOR DRAIN MFR MANUFACTURE(-R) SD SOAP DISPENSER W/C WATER CLOSET 1 =1'-0" CLG CEILING FE FIRE EXTINGUISHER MIN MINIMUM SDSV STATIC DISIPATIVE SHEET VINYL WD WOOD 1 CUR CLEAR(-ANCE) FEC FIRE EXTINGUISHER CABINET MISC MISCELLANEOUS SF SPECIALTY FINISH W/o WASHER&DRYER CMT CERAMIC MOSAIC TILE FF FACTORY FINISH,FINISH FLOOR MRGB MOISTURE RESISTANT SFGL SAFETY GLASS Woo WINDOW Is there a comment EXISTING BUILDING CODE: CMU CONCRETE MASONRY UNIT FIN FINISH(-ED) GYPSUM BOARD SHTG SHEATHING WF WALL FABRIC missing regarding the 1011.5.2 HEIGHT AND AREA FOR CHANGE TO AN EQUAL OR LESSER-HAZARD CATEGORY.WHERE A CHANGE OF OCCUPANCY CLASSIFICATION IS cc CLEAN OUT FLR FLOOR(-ING) MTL METAL SIM SIMILAR WFV WOOD FACE VENEER MADE TO AN EQUAL OR LESSER-HAZARD CATEGORY AS SHOWN IN TABLE 1011.5,THE HEIGHT AND AREA OF THE EXISTING BUILDING SHALL BE COL COLUMN FND FOUNDATION N NORTH SL SLOPE WG WIRE GUARD automatic sprinkler DEEMED ACCEPTABLE. CONC CONCRETE FOC FACE OF CONCRETE (N) NEW SND SANITARY NAPKIN DISPENSER WGL WIRED GLASS system or the rated CONT CONTINUOUS,CONTINUE FRP FIBERGLASS REINFORCED NA,N/A NOT APPLICABLE SP SPACE(-S) WM WIRE MESH nonbearing A IL CORR CORRIDOR PLASTIC PANEL NIC NOT IN CONTRACT SPEC SPECIFICATION W/O WITHOUT walls-interior? 308.5.1 CLASSIFICATION AS GROUP E.A CHILD DAY CARE FACILITY THAT PROVIDES CARE FOR MORE THAN FIVE BUT NOT MORE THAN 100 CP CARPET FRVR FLAME RESISTANT VAPOR BARRIER NDU SANITARY NAPKIN SQ SQUARE WOC WALK-OFF CARPET CHILDREN 2 1/2 YEARS OR LESS OF AGE,WHERE THE ROOMS IN WHICH THE CHILDREN ARE CARED FOR ARE LOCATED ON A LEVEL OF EXIT CS CONCRETE SLAB,SEALED FT FOOT,FEET DISPOSAL UNIT S/S STAINLESS STEEL WP WATERPROOFING DISCHARGE SERVING SUCH ROOMS AND EACH OF THESE CHILD CARE ROOMS HAS AN EXIT DOOR DIRECTLY TO THE EXTERIOR,SHALL BE DATE: 12/8/2023 CT CERAMIC TILE FTG FOOTING NOM NOMINAL ST STAIN WPS WALL PROTECTION SYSTEM CLASSIFIED AS GROUP E. CTJ CONTROLJOINT FWC FABRIC WALL COVERING NTS NOT TO SCALE STL STEEL WR WATER RESISTANT NM RCR CTR COUNTER(-TOP) GA GAUGE OC ON CENTER STIR STRUCTURE(-AL) WRGB WATER RESISTANT GYPSUM SEE IBC SECTION 907.2.3 FOR rew� DhecFetl DBL DOUBLE GALV GALVANIZED OD OUTSIDE DIAMETER STRG STORAGE WALLBOARD ALARM REQUIREMENTS #23047 DIET DETAIL GH GARMENT HOOK OPP OPPOSITE SV SHEET VINYL FLOORING WWF WELDED WIRE FABRIC Q ­E­ FIRE GLASS MESH MORTAR BOARD PCMU PRE-FACED CMU W/ WITH FIRE ALARM&DETECTION SYSTEM SHALL BE PROVIDED AT E OCCUPANCY. A0-O Page 2 of 29 WHILE EVERY EFFORT HAS BEEN MADE TO PERFORM A LICENSED COMPLETE AND ACCURATE PLAN REVIEW,IT DOES nncNl]Ecr ARE85]DS NOT EXEMPT THE FIRE MARSHAL'S OFFICE FROM CODE REQUIREMENTS OMITTED FROM DRAWINGS J\�L/ J\�L/ THAT ARE CAUGHT DURING FIELD INSPECTIONS. %n/y'//n�_ V Z V R AOE RICKS "�J Z 32"MIN sr 12/8/2023 I _ MIN 35" o h z z 35" 1'-6" 32"MIN I'I p"I MAX MAX FRONT APPROACH FRONT APPROACH UNOBSTRUCTED FORWARD REACH UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH FORWARD REACH PULL SIDE,CLEARANCE PUSH SIDE,CLEARANCE A) I I _ Z �e - 1 3'-6" 32 MIN 32"MIN 11 o MIN 36, MIN 35" I 1 20 TO 25 OBSTRUCTED HIGH FORWARD REACH (B) OBSTRUCTED HIGH SIDE REACH OBSTRUCTED HIGH SIDE REACH (A) (B) HINGE APPROACH HINGE APPROACH 2 OPERABLE PARTS&REACH RANGES PULL SIDE,CLEARANCE PULL SIDE,CLEARANCE 3/8"=1'-0" z 12"' 35 22 �\ MIN MIN 32" MIN z ~/ N 24" 35" V) MIN MIN 32" O I— `IF BOTH CLOSER AND O 2 LATCH ARE PROVIDED w W *'48"MIN IF BOTH CLOSER IS N 3 CLOSER AND LATCH PROVIDED (8) Z o PROVIDED Q'' W m = W HINGPUSH ESIDE,CO EARANCE 1 ACH 2 — _ O m � LATCH APPROACH � u,, S W PULL SIDE,CLEARANCE N a R a I., - wr?ow O mO yU Nww" Q W U hwviw M R8 a 5'-0"MIN 5'-0"MIN (b) z�o Smo z 24" 35" i g w r---------� 2 z �_ z v IN MIN 32" 1F�' Oz\ z_ d3r *48"MIN IF \ I L—� r—� \ ED CLOSER IS PROVIDED \ / (C) I I U - ----- 3 VERTICAL CHANGES IN LEVEL y ACCESSIBLE ENTRANCE GENERAL-SIGN MOUNTING HEIGHT N T-0"MIN 12"=1'-0" 1/4"-1'-0" 1/4"=1'-0" 1'-0"MIN,. 1'-0"MIN LATCH APPROACHr DO V ' PUSH SIDE,CLEARANCE CIRCULAR T-SHAPED TURNING SPACE TURNING SPACE n DOOR CLEARANCE REQUIREMENTS D 3 Do Prefered FIRE Signage ROOM •may, � w COUNTER-SINK COUNTER-SINK COUNTER-SINKe�y� M HOLES FOR SCREW HOLES FOR SCREW HOLES FOR SCREW bb HEAD(TYP) HEAD(TYP) HEAD(TYP) MITI MR 8" 8" 8" RADIUSED RADIUSED 1. SHALL BE FABRICATED FROM.080 ALUMINUM SHEET WITH MIN.OF.75"RADIUS CORNERS CORNERS CORNERS 2. FONT STYLE IS HANDEL GOTHIC BT CAPITAL FONTS WITH ADDITIONAL KERNING BETWEEN LETTERS RADUSED RADUSED RADUSED 3. THE SIGN FACE SHALL HAVE A WHITE 3M DIAMOND GRADE REFLECTIVE SHEETING(3990 CORNERS CORNERS CORNERSRISER SERIES VIP TYPE IX)APPLIED AS A BACKGROUND "o o X—SED 4. LETTERING/GRAPHICS SHALL BE ONE OF THE FOLLOWING: A. 3M ELECTROCUT FILM RED 1172 OR ORACAL 8300 TRANSPARENT CAL 201C RED 5-0 AFF _ -0 AFF _ 5-0" AFF • • OR EQUIVELANT IN DURABILITY,INVERSE CUT TO ALLOW REFLECTIVE 2 1/2"LETTERING 2 1/2"LETTERING BACKGROUND TO SHOW THROUGH LETTERING. RE T ROOA1 OMEN 1/2"STROKE 1/2"STROKE B. SCREEN PRINTED USING 3M 8801 SERIES TRAFFIC SIGN RED TRANSLUCENT INK 4 5. SIGNS USED IN BUILDING INTERIORS ARE NOT REQUIRED TO USE A REFLECTIVE MIN 3/4"RAISED RAISED MIN 3/4"RAIS MIN 3/4"RAISED RAISED BACKGROUND. LETTERS BRAILLE LETTERS BRAILLE LETTERS BRAILLE 6. ALL SIGNAGE AND CHANGES MUST BE PRE-APPROVED BY THE FIRE MARSHAL DATE: 12/8/2023 SURFACE MOUNTED PANEL SURFACE MOUNTED PANEL SURFACE MOUNTED PANEL SURFACE MOUNTED PANEL SURFACE MOUNTED PANEL NM RCR SIGN TYPE A SIGN TYPE A SIGN TYPE B SIGN TYPE H SIGN TYPE J #23047 8 RESTROOM SIGN GENERAL-SIGNS 8 SIGN AGE-SIGNAGE TYPES-RED vRaEc]n 1 1/2"=1'-0" 1 1/2"=r-o° 1 112"=1'-0° CITY APPROVED PLANS Reviewed for Code Compliance A�- PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Page 3 of 29 LICENEED PRCHIE AR B85]OB NON ABSORBENT NON ABSORBENT SURFACE TO 4'-0" R.'TE o SURFACET04'-O" ABOVE FINISH FLOOR WALL s 2/8/2023 ABOVE FINISH FLOOR a a >> 3 54"MIN 42". 1'-3"CLEAR 2'-0"1'-0" 12"MAX 3 a 0 GRAB MIN MIN GRAB ❑ ¢4 BAR BAR 3 RIM HT. J _ o RIM HT. T.O.SEAT � ,fO./ � � Y 60"MIN RIM HT. O z � rn Z 3 z H g CLEAR 8"MIN 16"-18" 24"MIN ACCESSIBLE STANDARD O ACCESSIBLE' NDU WHERE ACCESSIBLE 18"X30" U WATER CLOSET(W/C) CLEAR 48"MAX INDICATED URINAL URINAL LAVATORY MIRROR \ > UNO 1 U a NOTE:AT RESTROOMS/TOILET ROOMS THE TOWEL, La SOAP,AND SANITARY NAPKIN DISPENSERS ARE TO BE 1.PROTECTION UNDER SINKS INSTALLED SO AS NOT TO EXCEED 40"AFF TO ANY 606.6 EXPOSED PIPES AND SURFACES.WATER SUPPLY AND DRAINPIPES UNDER LAVATORIES > OPERATING CONTROLS,RECEPTACLE,OR DISPENSER. AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. w Do THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES AND SINKS. 1 O e = y 2.FLUSH CONTROLS 11 ` °P 4 a El604.E FLUSH CONTROLS.FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC.HAND OPERATED FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET. 1 g o - EXCEPTION:IN AMBULATORY ACCESSIBLE COMPARTMENTS COMPLYING WITH SECTION 604.9, ( z N o FLUSH CONTROLS SHALL BE PERMITTED TO BE LOCATED ON EITHER SIDE OF THE WATER 1 w iv . r � ACCESSIBLE SOAP TOILET NAPKIN TOILET CLOSET D PAPER TOWEL DISPENSERS PAPER DISPOSAL SEAT COVER i DISPENSER (SD) DISPENSER UNIT DISPENSER 3.TOILET PAPER DISPENSER. O (PTD) (TPD) (NDU) (TSCD) BE 7 DISPENSERS.TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION AND SHALL z @ BE INCHES(180 mm)MINIMUM AND 9 INCHES(230 mm)MAXIMUM IN FRONT OF THE THE WATER z @ ALL W/C PROVIDE ONE PROVIDE ONE ABOVE EA. CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER.THE OUTLET OF THE DISPENSER LOCATIONS VERIFY W/OWNER RESTROOM WATER CLOSET SHALL BE 15 INCHES(380 mm)MINIMUM AND 48 INCHES(1220 mm)MAXIMUM ABOVE THE FLOOR, v AND SHALL NOT BE LOCATED BEHIND THE GRAB BARS.DISPENCERS SHALL NOT BE OF A TYPE FLOOR 1- 1"MIN �- THAT CONTROL DELIVERY,OR DO NOT ALLOW CONTINUOUS PAPER FLOW. ���� GENERAL-FIXTURE MOUNTING 1 HEIGHTS 2 LAVATORY CLEARANCE 1/4"=V-0" 1"=1'-0" 0 U) NON ABSORBENT TOILET PARTITIONS O I-_ NON ABSORBENT SURFACE TO 4'-0" PROVIDES THE MANDATORY ❑ Z SURFACE TO 4'-O" ABOVE FINISH FLOOR WALL 27"(686 mm)FLOOR TO UNDER- Z LLI ABOVE FINISH FLOOR 3 3 54"MIN a SIDE REQUIREMENTS WHEN O J N 3 w MOUNTED IN THIS MANNER. LL 34"-36" — z 60"MIN 42". w A.D.A.ACCESSORY Of a �' J 1'-3"CLEAR APRON 0 Q ? 2'-0"1'-0" 12"MAX 3 GRAB MIN MIN CRAB O ¢ N BAR BAR 3 g RIM HT. O Z j z b J w L j m_ LLI T.O.SEAT - - ® _ ? W W � - 59" IN U FLOOR LINE w LLI CLEAR O -18" 24"MIN 5"MAX FOR FORWARD w CHILDREN TOILET PARTITIONS - O ACCESSIBLE CHILDREN 12"�� ACCESSIBLE 24"X APPROACH WATER CLOSET(W/C) CLEAR 42"MAX LAVATORY MIRROR Q LLI U ENO 3\"MAX FOR PARALLEL APPROACH rl DRINKING FOUNTAIN DETAIL 1.PROTECTION UNDER SINKS LJ 1/4"=1'-0" 606.6 EXPOSED PIPES AND SURFACES.WATER SUPPLY AND DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES AND SINKS. 2.FLUSH CONTROLS TABLE C604.11 604.6 FLUSH CONTROLS.FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC.HAND ADVISORY SPECIFICATIONS FOR WATER CLOSETS SERVING CHILDREN AGES 3.12 OPERATED FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE WATER CLOSET. EXCEPTION:IN AMBULATORY ACCESSIBLE COMPARTMENTS COMPLYING WITH SECTION 604.9, AGES 3& AGES 5-8 I AGES 9-12 FLUSH CONTROLS SHALL BE PERMITTED TO BE LOCATED ON EITHER SIDE OF THE WATER WATER CLOSET CENTERLINE CLOSET. TOILET SEAT HEIGHT 3.TOILET PAPER DISPENSER. GRAB BAR HEIGHT 18-20 20"-25" 25"-27" 604.7 DISPENSERS.TOILET PAPER DISPENSERS SHALL COMPLY WITH SECTION 309.4 AND SHALL DISPENSER HEIGHT 14" 14"-17" 17"-19" J.d BE 7INCHES(180 mm)MINIMUM AND 9INCHES(230 mm)MAXIMUM IN FRONT OF THE WATER rl CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER.THE OUTLET OF THE DISPENSER ry SHALL BE 15 INCHES(380 mm)MINIMUM AND 48 INCHES(1220 mm)MAXIMUM ABOVE THE FLOOR, �I AND SHALL NOT BE LOCATED BEHIND THE GRAB BARS.DISPENCERS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY,OR DO NOT ALLOW CONTINUOUS PAPER FLOW. C b o CHILDREN FIXTURE MOUNTING HEIGHTS V� v w`o �M U o rl W N U J M DATE: 12/8/2023 F CITY APPROVED PLANS eNM RCR #23047 Reviewed for Code Compliance PRO w PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS AO-2 Page 4 of 29 LICENSED -CHI- ARE85]OB EXIT signage needed in this exterior area as well. This is a relitivily small area that three doors exit to.The path to the left is NOT cleary defined. RTAOE aDpk/Ho y s 12/8/2023 79' FE /EXIT 3' 11!MF / 15' 3' 7 68 / I / EXIT \ / / I \ / I I NI a.\ / I I I 1 �� 4' 1 r s T 20. ' 37' R / —W� — — — — — — — — — i — — — — — — — — — — — — — — — ELEC w I / EXIT T� 30' — — — —78 — — — 1 — — — — 23— — — — — -- — — — — s' z,I NI — — — — — �I �I I I FE \ LADDER �I w $ T I I I L — 20 18' X 13' Q _ _ C]T — — — — , — — — w — 13 — —EXITr'E- 0 O FE O J �I H z 3�w L 5, L N bI I I of Lu Lu m Q L - - - - - - - - - 40 - - - - - - - - - L - - - -18- - - - J w LU wJ IY m 11 (n w Q LLI LLI 1 EXIT PLAN Cj aA o M U 8 U �� � N v rl W N U J M DATE: 12/8/2023 NM RCR CITY APPROVED PLANS #23047 Reviewed for Code Compliance RRawrn PLANS MUST BE ON JOB SITE �0-A FOR ALL INSPECTIONS S Page 5 of 29 LICE -CHI— A I B85]OB 1.COL 11— s]12/8/2023 ALL existing fire and life safety systems need to be in working order and monitored. OCCUPANT CLASSICICATION A-3 OCCUPANT LOAD — E F-1 KITCHEN 360 SF/200= 2 I, 0 DAYCARE 2091 SF/ 35=60 STORAGE 1505 SF 1300= 5 0 OFFICE/BUSINESS 2115 SF/150= 14 M RESTROOM/CIRCULATION]PATIO 2656 SF = 0 EXERCISE/LOCKER ROOMS 10,134 SF/ 50= 203 TOTALOCCUPANTS 284.� U) O LL } Z JQ O LLz Q z Q N � � oU LU in O s � C w U � U Q Lu O I;= walls/barriers and barriers become one of the most J t fire and life safety components of this building since F1 no fire sprinklers or fire alarms.erative that all new and existing fire walls/barriers their integrity. Penetrations shall be kept to a minimume shall be no unprotected penetrations. The doors andlies shall not diminish the fire ratings and shall be tested Uected IAW NFPA 80 when indicated. 7,860.82 sf U N aA o M � W U 2 HR FIRE FF-- b BARRIER '\ - ^ 0 7� 7J 1 11 y v r W • K PROVI EFIRE ALARM r� DF SYSTEM FOR THIS AREA U r1 DIr7 can eaR. LC L-i 2 HR FIRE BARRIER FIRE BARRIER TO EXTEND TO LJ BOTTOM OF ROOF SHEATHING 2CCUPANTLOAD DATE: 12/8/2023 NM RCR rew� cn«x�a OCCUPANCY CLASSIFICATION 1/16"=1_0 CITY APPROVED PLANS �3047 P D,ECiF Reviewed for Code Compliance PLANS MUST BE ON JOB SITE AO-4 FOR ALL INSPECTIONS Page 6 of 29 LICENSED PRCHn- ARE85]OB 1 A7FA (E)FENCE,TYP IDN-IAW sa°E aoaHo 2 2/e/2023 N buildingssh withapprovearess identification,legible and (E) LANDSCAPING placed in a position that is 4-41/16 POST TOP visible from the street or road & GAME FIELDS 2"SQUARE TUBE RAIL F fronting the property. CQTF: 11 11 11 11 11 (3)'7RU CLOSE"SPRING TENSION w high and right as SELF-CLOSING HINGES,TYP COrISpICUOUSIy possible. �IHI-If IFIHI$ 13/8"X 112"U-CHANNEL RAIL OU ALL existing fire and 10',3/16"WALL SO.POST Characters shall contrast life safety systems PANIC BAR ON PLAY YARD 1"SQUARE PICKET,TYP a with their background. need to be in working SIDE,DASHED,NOTE 1 Address identification shall order and monitored. 2"SQUARE UPRIGHT > HIPANIC SHIELD ON PLAY YARD be Arabic numbers Or letters. SIDE,DASHED,NOTE 1 1 318"X 1 1/2"U-CHANNEL RAIL Numbers shall not be 12"HIGH X GATE WIDTH PLATE ______ Spelled out. AT BOTTOM,BOTH SIDES 2"SQUARE TUBE RAIL I Z o Commercial Buildings should g CONCRETE FOOTING,IIIIIIIIIIIII have minimum 12"tall - 3000 PSI numbers and shall be affixed UNDISTURBED OR • to the building. Numbers _ IIIIIIIIIIIII COMPACTED SUBGRADE • may be affixed to monumentk • signs but as a secondary (E) BLDG address location.Street NOTE: name not needed if numbers 1. GATE SECURITY KIT SHALL BE BY HOOVER FENCE COMPANY,LOCKEY USA PANIC SHIELD KITS,KIT PSDX-SECURITY KIT WITH BLACK are displayed facing FINISH.INSTALL PER MANUFACTURES INSTALLATION GUIDELINES AND RECOMMENDATIONS.INSTALL GATE assigned road. SECURITY KIT ON THE(1)PLAY YARD EXIT/ACCESS GATES.MOUNT GATE SECURITY KIT WITH MANUFACTURE PROVIDED aSSI g' STAINLESS STEEL HARDWARE TO GATE AND FENCE FRAMING AS PER MANUFACTURE GUIDELINES AND RECOMMENDATIONS. PROVIDE ANY ADDITIONAL BACKING TO PROVIDE A SECURE INSTALLATION. Suite/Apt/Unit numbers shall be affixed near the main 2 EGRESS GATE DETAIL entry door(s),a minimum 4" 3/8"=1'-0" tall and shall include the word"SUITE"or"APT"or O "UNIT"etc. _O LL EMERGENCY ACCESS KEY BOX IAW 2018 IFC 1 N 3 5D6 (E) BLDG 0 (E)FENCE,TYP Knox Box: w d www.knoxbox.com � If no existing Knox Ur Q LLJ Box,one shallll be F_ be installed z to the right of the main access door(s).All keys Q shall be identified with a LLI tag indicating what the key IJ Q unlocks.Box should be _ Q mounted 5-6 feet from Q REA OF WORK ground level. > � Alternative locations shall J Qbe LLI MarshalovedbytheFire (E) PARKING SPACES `I (E) LANDSCAPING IF there is an(E)Knox O bp o BOX,all keys/codes shall Q (E)LANDSCAPING (E)SIDEWALK be updated. REPLACE(E)GATE W/ONE THAT C� b O MATCHES DETAIL REQUIREMENTS '~ W ° ( PARKING ' (E) PARKING o � SPACES SPACES � � ¢ 1:� M Fire Hydrants(FH)IAW TFSD 403&404: New and existing,shall be equipped with: ELIZABETH BLVD �l F--'1 Pointing towards the main fire access road Public FH shall be red with white caps NORTH Street shut-off valve lid shall be embossed FIRE (when new)and painted red Site DATE: 12/8/2023 U 1"=20'4• NM RCR CITY APPROVED PLANS #23047 Reviewed for Code Compliance vRo�wru PLANS MUST BE ON JOB SITE Al-� FOR ALL INSPECTIONS Page 7 of 29 LICE NSED CHITECT ARE85]OB R.COL RIDCK� sT 12/8/2023 r w C, o EXERCISE >) POOL C EQUIPMENT O w a w a TENNIS UP POOL LOCKER RM 0 ILL z 9z O 'i Q LLD_ N k wO 6 InI.- 3 LU LU L U w LL O 0c LOCKER RM U LC Q LJJ C) FE EXIT 1. PATCH&REPAIR WALLS WHERE DEMOLITION WORK OCCURS. 2. PATCH&REPAIR FLOORS IN PREPARATION OF REMOVE&INFILL WINDOW REMOVE(E)GYP BD ABOVE NEW FLOOR FINISHES. BRICK ON EA SIDE OF WALL 3. REFER TO MECHANICAL,PLUMBING,&ELECTRICAL FOR ADDITIONAL DEMOLITION WORK. (E)CLASSROOM EXIT 6 GENERAL DEMO NOTES L�\ � 1/4"=1'-L)" OFFICE OFFICE ® V /Demo Keynotes — 2 2 yl 1 12 F 1 1 STG bp T rl o Key 1 7 THIS WALL COULD BE LOAD-BEARING. 1— � J RELOCATE FE , Value Keynote Text REMOVE GYP BD,THEN HAVE STRUCTURAL 2 LJ l C a ENGINEER REVIEW THE WALL 3- J 1 ________ _ __ _ — C� v 1 REMOVE WALL IN ITS ENTIRETY AS SHOWN 2 —J EXERCISE o BY DASHED LINES REMOVE ALL CORRIDOR REMOVE(E)GYP BD ON w NQ W p EA SIDE OF SOFITT WALL III 2 REMOVE DOOR SYSTEM IN ITS ENTIRETY X APPLIANCES ELEC �) M w F^ 3 REMOVE CASEWORK IN ITS ENTIRETY C—Q——— 4 REMOVE PLUMBING FIXTURE OO ----- - LOBBY V + oN 5 REMOVE WALL AS REQUIRED FOR NEW 1 2 7 r CORRIDOR W DOOR,RELOCATE ANYTHING ON WALL AS g OFFICE O O L 5 FE _ y REQUIRED,MODIFY BASE AS REQUIRED _ BLADDER sV- d 6 REMOVE WALL HEATER 2 — L� / � WOMEN ^� n 7 REMOVE TILE FLOOR&BASE REMOVE c0 p M 8 REMOVE RUBBER FLOOR&BASE 2 O 41 1 u �� APPLIANCES 9 REMOVE CPT&BASE 2 7 F 7(D REMOVE(E)GYP BD ON O W ��� O MEN O � THIS WALL COULD BE LOAD-BEARING.REMOVE GYP STG 2 CORRIDOR EA SIDE OF SOFITT WALL ENGINEER REVIEW THE WALL. 6 O L \ / / W EXIT FE 5 O � REMOVE(E)WOOD/GYP BD ABOVE THERE APPEARS TO BE ASBESTOS FLOORING IN THE FACILITY.IF THE BRICK ON EA SIDE OF WALL ASBESTOS IS DISTURBED IN ANYWAY,ABATEMENT SHALL BE PROVIDED. (E)CLASSROOM ASBESTOS FLOORING CAN BE COVERED BY NEW FLOORING. D Q DATE: 12/3/2023 (E)CLASSROOM II VESTIBULE CITY APPROVED PLANS NM RCR 5 Reviewed for Code Compliance #23047 PROJECT# s s s s s PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS A1- ■ 1 DEMO FLOOR PLAN Page 8 of 29 LICENSED PLICHITECT aRE85]OB I I Rae RDa� sT 12/8/2023 UP II Z Q J d Q LU C) Q LL V) o 0 �uuI O J U) w �nl Q z m (\J Q6 W W � p� W m Co w 6u) 0 Q LLI d I I --- N U aA o PP Hi 00 ---- cc T n rl W N J M POSSIBLE ASBESTOS CITY APPROVED PLANS DATE: 12/8/2023 NM RCR Reviewed far Code Compliance rew� en«k�a #23047 PLANS MUST BE ON JOB SITE vRo,wTu POSSIBLE ASBESTOS AREA FLOOR FOR ALL INSPECTIONS Al-2 n PLAN L 1/8"=11_01, Page 9 of 29 LICENSED PRCHI- AR B85]OB R.COL RIICCK$ s]12/812023 FIRE - FM w C, }O t U W a w a Fire Extinguisher TI/REMODEL:If construction alters the paths of DP egress and/or any existing FE's,ensure that travel distance and correct mounting stays consistent with 2018 IFC 906 and NFPA 10. Portable fire extinguishers shall have a minimum rating of 2A-10B:C. The travel distance to an extinguisher shall not exceed 75 feet. Please assess if remodel will require more FE's. Z 1. ANY LOCATION WHERE WOOD IS TOUCHING CONCRETE,MASONRY,CMU,OR STEEL SHALL BE PRESSURE TREATED. J 2. ALL WOOD SHALL BE DOUGLAS FIR#2 OR BETTER. D_ 3. ALL NEW INTERIOR WALLS SHALL BE 2.4 W/5/8"GYP BD EA.SIDE U.N.O. 4. ALL NEW INTERIOR WALLS SHALL HAVE SOUND BATT INSULATION Q 5. PATCH,PAINT,&REPAIR WALL,CEILING,&FLOORS AS REQUIRED FOR NEW WORK.MATCH TEXTURE&PAINT,TYP. LL O 6. ALL FINISHES SHALL BE VERIFIED&SELECTED BY OWNER. z ❑ O n GENERAL NOTES J z N W z aZ W In J LLJ LU W Q 0 m O w FE Q W O I I L-—-—-—-—-—-—- ----------------------------- I RELOCATED FE $"I I CLASSROOM t (E)OFFICE (E)OFFICE KI H U ® JUICE BAR (E)STG V 21 0 20 19 18 14 (E)RM Q 11 (E)RM � 6-9 OLDS 10 22 OCCUPANTS q 7TH-12TH GRADE )s U CORR 2 6 12 IM, E \ r� 15 WAITING — — — — — — — ---------- J CORR T 0 CORR 1 •3^ U 1s 27 1 ® o OFFICE LADDER CLASSROOM 3 1 2 FE 3 d v m PROVIDE PANIC, Dr 25 0 13 rc �• d PUSH-PAD OR Q � � 10-12 YR OLDS ADA RR (E)WOM R (E)MEN RR LEVER THAT LL ❑ 130CCUPANTS DEACTIVATES �STG (E)RM BREAK RM 8 LOCK IN A SINGLE 26 5 M MOTION FRR d CH D RR w 9 t CORR 4 RECEPTION + 22 L J 23 17 7 FE 1z 0 Q — — 9 11 1 CLASSROOM 2 A2-2 A2 3 10 24 (E)VESTIBULE CITY APPROVED PLANS DATE: 12/8/2023 NORTH 3-5Y OLDS 1 NM RCR T 250CCUPANTS Reviewedfor Code Compliance rew" Ch.- PLANS MUST BE ON JOB SITE PROJECTu ------------------------------------------------- ------� FOR ALL INSPECTIONS n NEW FLOOR PLAN A2-1 118"=1'-0" Page 10 of 29 oinspected walls/barrie=indicated. barriers become one of the most LICENSED t fire and li components of this building since no fire spor fire alarms. erative that and existing fire walls/barriers their integnetrations shall be kept to a minimum ..FILE NO.WP 4l- GENERIC 2 HOUR FIRE 40 TO STC SOUND e shall be tected penetrations. The doors and R.COE 11- lies shall nosh the fire ratings and shall be tested GYPSUM WALLBOARD,WOOD STUDS P° 2 8/2023 ected IAW0 when indicated. FIRE DESIGN: BASE LAYER 5/8"TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHTFIRE - FM ANGLES TO EACH SIDE OF 2X4 WOOD STUDS 24"O.C.,WITH 6d COATED NAILS,1 7/8" LONG,0.085"SHANK,1/4"HEADS,24"O.C.FACE LAYER 5/8"TYPE X GYPSUM 1. ANY LOCATION WHERE WOOD IS TOUCHING CONCRETE,MASONRY,CMU,OR STEEL SHALL BE PRESSURE TREATED. WALLBOARD OR GYPSUM VENEER BASE APPLIED AT RIGHT ANGLES TO EACH SIDE 2. ALL WOOD SHALL BE DOUGLAS FIR#2 OR BETTER. WITH 8d COATED NAILS,2 3/8"LONG,0.100"SHANK,1/4"HEADS,8"O.C. 3. ALL NEW INTERIOR WALLS SHALL BE 2.4 W/5/8"GYP BD EA.SIDE U.N.O. 4. ALL NEW INTERIOR WALLS SHALL HAVE SOUND BATT INSULATION JOINTS STAGGERED 24"EACH LAYER AND SIDE.(LOAD-BEARING) 5. PATCH,PAINT,&REPAIR WALL,CEILING,&FLOORS AS REQUIRED FOR NEW WORK.MATCH TEXTURE&PAINT,TYP. 6. ALL FINISHES SHALL BE VERIFIED&SELECTED BY OWNER. SOUND DESIGN: r SOUND TESTED AS CONSTRUCTED FOR FIRE z o GENERAL NOTES 2 2 HOUR FIRE BARRIER o U w a 1 w 7 e (E)4 HR BRICK WALL,TABLE 721.1(2)1-1.1 �° Oo o o ELOCATED FE REPLACE GYP BD&FILL BUILDING OPENINGS ALONG 2 HR CHE ® FIRE WALL TO MATCH DETAIL 2,A2-2 18 0 (E)OFFICE (E)OFFICE JUICE BAR CLASSROOM? F 20 19 14 Fill Z J CL. FIRE BARRIER TO EXTEND TO 00 O BOTTOM OF ROOF SHEATHING o o J - LL � CORR 2 Q z W 15 N Z WAITING z I— m LLJ 2X6 FRAMING ] W LU = GYPSUM BOARD ON 00 L CORR 3 --- EXTERIOR OF WALLS Q 16 ST TO BE EXTERIOR RATED w (E)4 HR BRICK WALL,TABLE 721.1(2)1-1.1 (SUCH AS DENSGLASS) Q LLJ UJ z7 Q 1 1'-8" T_8" 2'-6" __ LADDER OFFICE CLASSROOM 3 i)F 25 Q STG 28 N 7 3 ECEPTION CITY APPROVED PLANS V s 0 © FRR Reviewed for Code Compliance 4 U 1� 22 CHILD R w PLANS MUST BE ON JOB SITE 23 FOR ALL INSPECTIONS V t I E!] I - Q 3 CORR 4DO 6 FR G \Qy A2-2 Q FV71 REPLACE GYP BD ALONG 2 HR FIRE Cn 6 M —J WALL TO MATCH DETAIL 2,A2-2 2X6 FRAMING 0 V *o FE ^ W v O 11 Q (E)CEILING >d (� o ff��7 13._9. L 5/8"GYP ED J M 10 CLASSROOM 2 (E)4 HR BRICK WALL,TABLE 721.1(2)1-1.1 (E)VESTIBULE C� SOUND BAIT l 24 � INSULATION F--{ COVER WOOD ABOVE W/(2)LAYERS TYPE X GYP BD ALONG 2 HR FIRE WALL TO 2X6 FRAMING MATCH DETAIL 2,A2-2 16"O.C. DATE: 12/8/2023 P.T.SILL NM RCR rew" #23047 c.- PROJECT# 1 NEW FLOOR PLAN-Callout 1 3 WALL SECTION Page 11 of 29 LICE NEED PRC n-T AR 885]OB ELEC a.STTE apex 1. ANY LOCATION WHERE WOOD IS TOUCHING CONCRETE,MASONRY,CMU,OR STEEL SHALL BE PRESSURE TREATED. 12/8/2023 2. ALL WOOD SHALL BE DOUGLAS FIR#2 OR BETTER. 3. ALL NEW INTERIOR WALLS SHALL BE 2x4 W/5/8"GYP BD EA.SIDE U.N.O. 4. ALL NEW INTERIOR WALLS SHALL HAVE SOUND BATT INSULATION CO RR 5. PATCH,PAINT,&REPAIR WALL,CEILING,&FLOORS AS REQUIRED FOR NEW WORK.MATCH TEXTURE&PAINT,TYP. 6. ALL FINISHES SHALL BE VERIFIED&SELECTED BY OWNER. nWOMEN AIR WALLS&NATCH TEXTURE&PAINT,TYP. GENERAL NOTES 17 FE L AD 6 RR 0 (E)MEN RR BREAK RMN ' NO WORK J r I �I 31 1 T T J 2X6 FRAMING 114 FLOOR PLAN-Callout 2FLOOR PLAN-Callout 2 J d LL O Z g J O LL LL N z Z Qp W W F W p W m Of O Q U wJ Q diw N U aA o M � W 'o U � rl W N U J M DATE: 12/8/2023 CITY APPROVED PLANS ONM Rca #23047 Reviewed for Code Compliance PROJECT# PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS A2-3 Page 12 of 29 LICENSED -CHIn- 1101S sT I I'D' 023 ............. o Demo Keynotes Key Value Keynote Text O 11 IREMOVE LIGHTFIXTURE ILL 12 1 REMOVE MECHANICAL FIXTURE z 13 1 REMOVE GYP BID CEILING 0 LL z 0� LU w LU LU 0 0 l 02 �) Ll LLJ C) Fj . . . . . . . . . . . . . . . REQUREMOIRED O FVE SFFITOR FIRE 77"FRAMING AS IRE BA RR ER In' U1 F77 I I I 1. PATCH&REPAIR CEILINGS WHERE DEMOLITION WORK OCCURS. 2 REFER TO MECHANICAL,PLUMBING,&ELECTRICAL FOR ADDITIONAL DEMOLITION WORK. CITY APPROVED PLANS DATE: 12/8/21323 oGE RCR 17— M�GENERAL CEILING DEMO NOTES Reviewed Code Compliance 7.7 Ch- -0 #23047 PLANS MUST BE ON JOB SITE PROJECT# FOR ALL INSPECTIONS DEMO RCP -0 1/8"=V-0 Page 13 of 29 LICENSED -CHI— ARE85]OB R.�COE RIDCKS s]1.8/2023 O LL z o O J zz z J 0Y m w w ? w 0 w m U � S O � � U) � w Q di z F11 E)WOO NEW WOOD .r. GYP BD{jrf .�� � � bpo w BB I (E)CEIL'G o0 8"=SOFFI ® (E)CEIL'G W NEW SOFFIT IN PLACE OF DEMOED WALL ( W - _ _ IE)WOOD d 1u GVP BD A E WOOD (EWOOD o-NEW SOFFIT TO(El WOODNEWMATCH T.O.WAL; , ':C, CABINETS cn GYP BID (E)CEIUG - (E)WOOD (E)WOOD 1. REFER TO MECHANICAL&ELECTRICAL FOR NEW FIXTURES,DEVICES,ETC. $ $ SIFT r 141LING�GENERALNOTES C�RYIAPPROV APPROVED PLANS ewedfor Code Compliance N^DATE. 1v8=2R 3 CR PLANS MUST BE ON JOB SITE D PEoyµ NEW SOFFIT IN PLACE OF DEMOED WALL FOR ALL INSPECTIONS n NEW RCP A7- Page 14 of 29 LICENSED -CHn- ARE85]OB 4 TYP 2'-6" 1'-6" 2'-9" L, 2'-9" 2'-0" 2'-0" 2'-9- v 2'-6" 3'-0" 1'-6' /-3/8" R.COL 11—"''y _ EPDXY PT EPDXY PT 1 EW SOF IT TO MATCH T. .WALL C INET PT s]12/8/2023 EPDXY PT EPDXY PT� � fV' 24X36 ® L�PT _ TYP 3 TYP 2 TYP 1 Jid 6�- SS COVE BASE SS COVE BASE SS COVE BASE SS COVE BASE 6"RUBBER BASE 2'-6" �'-6"� 2'-9" �1'-9"� 3'-0" T-0" �1'-9"�2'-6" 3'-0" �1'-6"� 3/8" 1 ADA RR 1 2 ADA RR 2 ADA RR 3 ADA RR 4 BREAK RM 1 BREAK RM 2 BREAK RM 3 1/4"=1'-0" 1/4"=1'-0" 3 1/4"=1'-0" 4 1/4"=1'-0" 5 1/4"=1'-0" 6 1/4"=1'-0" (E)BEAM PT a EPDXY PT EPDXY PT J \V.EPDXY PT EPDXY PT 24X36 LL LL u K 6"RUBBER BASE SS COVE BASE SS COVE BASE SS COVE BASE RT SS COVE BASE n BREAK RM 4 n CHILD RR 1 n CHILD RR 2 n CHILD RR 3 l CHILD RR 4 O L _1'-0" U 1/4"=1'-0" U 1/4"=1'-0" U 1/4"=1'-0" 1/4"=1'-0" Z ILL O Z 0 JQ Z N � J Z o W F- W W = O W W — O 1-- sw Q W Z N 4-1 U aA o M U � rl W N �I U J M DATE: 12/8/2023 CITY APPROVED PLANS NM RCR Reviewed for Code Compliance #23047 vRo�Ecru PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Page 15 of 29 LICENSED P CHnE -s- Door Schedule R.A�E IRDAHO DOOR FOB FRAME sT 12/8/2023 Access DOOR ROOM EL Width Height Thickness Material Finish Accessories Control Material Finish Comments CLASSROOM: LEVER.DOOR CAN BE LOCKED FROM THE INSIDE. LEVER ALWAYS OPENS FROM THE INSIDE. FIRE FM 1 ADA RR a 3'-0" 6'-8" 13/4' S.C.WOOD STAINTO PRIVACY W/INDICATOR No HM PT MATCH(E) ENTRY: LEVER.KEY REQUIRED.DOOR CAN BE LOCKED FROM THE 2 (E)WOMEN RR a 3'-0" 6'-8" 13/4" S.C.WOOD STAINTO PASSAGE/CLOSER No HM PT INSIDE.LEVER ALWAYS OPENS FROM THE INSIDE. MATCH(E) BR RM 3'-0" 6'-8" 13/4 C.WOO STAI CLA OM/C R No HM PASSAGE: LEVER.ALWAYS UNLOCKED.LEVER OPENS FROM CH(E EITHER SIDE. y 4 KITCHE a 3-0" '-8" 13/4' M PT CLASSROOM/C OSER/KEYPAD Ves HM PT 90 MIN TED z 6 CORR2 a 3'-0" '-8" 13/4' M PT CLASS OOW CLO ER/KEYPA/PANIC Yes HM PT 90 MIN TED PRIVACY: LEVER.DOOR CAN BE LOCKED FROM THE INSIDE.LEVER w DEACTIVATES LOCK IN SINGLE MOTION. CHI 0" 00 TAI GE o HM M H(E) STORAGE: LEVER.KEY REQUIRED.THE OUTSIDE LEVER IS 8 FRR c 2'-8" 6'-8" 13W HM PT STORAGE/CLOSER No HM PT ALWAYS LOCKED.LEVER ALWAYS OPENS FROM r 9 CHILD RR a T-0" 6'-8" 13W S.C.WOOD STAINTO PASSAGE No HM PT THE INSIDE. MATCH(E) w 10 CLASSROOM a T-0" 6'-8" 1314 1 HM PT ENTRY LEVER/WEATHERSTRIP/THRESHOLD No HM PT o- c ooM2 s'-o" s'-s^ 13a woo STAI H(E oRAG No H n DOOR HARDWARE GENERAL NOTES 'w 12 CORR4 a 3'-0" 6'-8" 13/4" HM PT CLASSROOM/CLOSER/KEYPAD/PANIC Yes HM PT 90 MIN RATED Qi 1/4"=1'-0" 13 CLASSR OM3 d 6-0" T-0" 3/4^ M PT CLASS OOW CLO ER/KEYP /PANIC HM PT 90 MIN RATED N DOOR HANDLES,PULLS,LATCHES, LOCKS,AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE SHALL NOT REQUIRE TIGHT GRASPING,PINCHING,OR TWISTING OF . THE WRIST TO OPERATE.(IBC SECTION i 1010.1.9.1) ANY EXIT DOOR WITH A KEYED LOCK TO BE READILY DISTINGUISHABLE AS BEING LOCKED OR PROVIDE A PANIC, PUSH-PAD,OR LEVER THAT DEACTIVATES LOCK IN A SINGLE Q MOTION. SMALL THUMB LOCKS NOT SOUND ATTENUATION ALLOWED. BATTS U) 5'-4^ ANY DOOR OTHER THAN MAIN EXIT W S/8•GYP BD DOOR TO HAVE DOOR HARDWARE THAT [) } 3'-4" 5'-0" 2' 3'-0" 2'-6" 2'-6' METAL STUD FRAMING UNLOCKS LOCK IN A SINGLE MOTION. 2'-8• 2 LL H.M.FRAME,11 p FOAM-IN-INSULATION PROVIDE SIGN ON MAIN EXIT DOOR, Z o5 It J W "THIS DOOR TO REMAIN UNLOCKED Q WHEN BUILDING IS OCCUPIED." LL J z � - - N w U Z � � LUm W L U w U)DOOR The fire walls/barriers and barriers become one of the most 0 IY S 0Y important fire and life safety components of this building since O CAULKING AROUND there are no fire sprinklers or fire alarms. PERIMETER OF DOOR Q W Oa © cc dO FRAME(BOTH SIDES)TYP It is imperative that all new and existing fire walls/barriers DOOR TYPES INTERIOR DOOR FRAME DETAIL maintain their integrity. Penetrations shall be kept to a minimum 1/4"=1'-O" 1 3"=1'-0" and there shall be no unprotected penetrations. The doors and assemblies shall not diminish the fire ratings and shall be tested and inspected IAW NFPA 80 when indicated. U Fire Doors shall be IAW IFC 705,2018 �.-( ed.and NFPA 80,2016 ed. U .� taA o M W U � rl W N U J M CITY APPROVED PLANS DATE: 128/2023 Reviewed for Code Compliance NM RCR rew" cn«k"a PLANS MUST BE ON JOB SITE #23047 PROJECT# FOR ALL INSPECTIONS A9-0 Page 16 of 29 LICENSED -CHn— ARE85]OB R.�COE RIDCK� s]12/8/2023 1. ALL FINISHES SHALL BE SELECTED BY OWNER 2. VERIFY ALL FINISHES W/OWNER CLASSROOM 7 (E)OFFICE (E)OFFICE KITCHEN JUICE BAR (E)STG 21 20 19 18 14 (E)RM 11 (E)RM 13 10 FRP TO 8'-0"W/STAINLESS STEEL COVE BASE (SANICOVE BY CRANE COMPOSITES), EPDXY PAINT WALLS&CEILING A (E)STG J' CORR 2 TEXTURE&PT TO MATCH(E) 12 TEXTURE&PT TO MATCH(E) 15 8"RB ORR WAITING CORR 7 16 G 0 ' � TOUCH UP TEXTURE 8 PAINT,TYP OFFICE 27 FRR PAINT WALL 26 CLASSROOM 3 PAINT ALL WALLS, DF STG 2$ 6"RUBBER BASE C] 22 Q CARPET, LL 0 6"RUBBER 26 RE TION d PAINT ALL 2 (E)RM ADA RR BREA RM z J WALLS cc© 0 O LL ac z ILD RR CORR 4 6"RB N /� TEXTURE&PT TO MATCH(E) Z TEXTURE&PT TO MATCH(E)J 17 Z FRP TO 4'-0"W/STAINLESS STEEL COVE BASE 2 m Q (SANICOVE BY CRANE COMPOSITES), W = a EPDXY PAINT WALLS&CEILING FRP TO4'O"W/STAINLESS STEEL COVE BASE (E)WOMEN RR (E)MEN RR 0 2 m 2 CLASSROOM 2 (SANICOVE BY CRANE COMPOSITES), O S (n EPDXY PAINT WALLS&CEILING 7� 24 2 (n Z (E)VESTIBULE Q LU LL PAINT ALL WALLS, 6"RUBBER BASE 1 FINISH PLAN 1/8"=1'-0" U aA o M U � rl W N U J M Do DATE: 12/8/2023 CITY APPROVED PLANS NM RCR �w� DhhecFetl Reviewed for Code Compliance #23047 PROJECT# PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Page 17 of 29 LICENSED -CHIIECT A I B85]OB P-LAM FINISH RCOL I�on�i�O 2'-l" iz• 2'-1" 12/8/2023 P-LAM FINISH P-LAM FINISH 3mm PBANDING EDGE 3mm PVC EDGE v 3mm PVC EDGE PROVIDE BACKING,TYP. WIRE PULLS WIRE PULLS DOORS P-LAM DRAWER DRAWER WIRE PULLS L J ADJ.SHELF(VES) 4 DRAWER J ?: P-LAM FINISH G x P-LAM FINISH h x �o P-LAM FINISH - LL u LL DRAWER J¢ z 3 LL ADJ.SHELF x N Z WIRE PULL,TYP DRAWER ILL 4"RUBBER BASE 4"RUBBER BASE 4"RUBBER BASE 3 P-LAM FINISH 1 BASE CABINET 4 DRAWER 2 BASE CABINET SINK DETAIL 3 BASE CABINET SHELVES DETAIL UPPER CASEWORK DETAIL '< 1"=1'-0" 1"=1'-0" 1"=1'-0" L 1"=1'-0" VENTSTACK TPO APPROVED SEALANT LL STAINLESS STEEL CLAMP O O TPO ONE PIECE BOOT o5 LL Of + SPECIFIED FASTENER AND PLATE z Q O HEAT WELDED LAP METAL FRAME O i > 2 X 4 WOOD NAILER FLASHING RECEIVER LL LLJ COUNTER FLASHING Q z U) TPO MEMBRANE FASTENED @ 18"O/C N Q MECHANICALLY FASTENED COVER BOARD COUNTER FLASHING TO Z o E END DOWN TO)CrO AGAINST NST OT DAMAGE PROTECT LU LJ_I LU w J INSULATION FASTENERS,8"O/C O S Q INSULATION BASE FLASHING U) w ~ LL1 Q LLJ ROOF DECK ROOFING,THICKNESS VARIES. WOOD BLOCKING @ DECK FIBER CANT STRIP SET IN BITMEN NOTE: NOTE: 1.CURB,WOOD NAILER,INSULATION AND SEAL STRIP TO BE SUPPLIED BY CURB MANUFACTURE. 2.4 X 4 PRESSURE TREATED PLATE TO BE USED FOR LEVELING OF CURB. 1. DO NOT CUT PREFABRICATED BOOT.IT MUST BE PULLED OVER VENT PIPE. NOTE: 2. PREFABRICATED BOOTS ARE AVAILABLE IN SMALL& CONTRACTOR TO BUILD FLAT WOOD CURB LARGE SIZES,AND MUST BE USED WHENEVER POSSIBLE FOR FACTORY CURB TO SIT ON IF REQUIRED TO FLASH PIPES 1"TO 8"IN DIAMETER. BY MANUFACTURER. �) U PREFABRICATED VENT PIPE FLASHING �TYP.EQUIPMENT&VENT CURBEQUIPMENT&VENT CURB �3"=1' �1 1_0„ by -------------- M U o rl W N U J M DATE: 12/8/2023 NM RCR CITY APPROVED PLANS #23047 Reviewed for Code Compliance PHOJwru PLANS MUST BE ON JOB SITE Al 0-0 FOR ALL INSPECTIONS Page 18 of 29 SECTION 23 1000-GENERAL PROVISIONS C.PIPING: 2.2 PIPINGAND FITTINGS: PART 3-EXECUTION PART 1-GENERAL 1.IDENTIFY ALL PIPING AS TO THE SERVICE OF THE PIPE AND THE DIRECTION OF FLOW.THE LETTERS SHALL BE%INCH HIGH ON A.GENERAL 3.1 WORKMANSHIP: 1.1 SCOPE: PIPING I-1/4 INCHES 0R SMALLER,%INCH HIGH ON PIPING I-1/2 T0 TWO INCHES,1-1/4 INCHES HIGH ON PIPING UP TO SIX 1.UNDERGROUND SANITARY SEWER SHALL BE INSTALLED AT%"PER FOOT SLOPE,UNLESS OTHERWISE INDICATED.IF SUCH SLOPE A.GENERAL: INCHES,AND 2-1/2 INCHES HIGH ON 8 INCH PIPING 0R LARGER.FLOWARROWS SHALL BE AT LEASTSIX INCHES LONG.THE IS NOT POSSIBLE DUE TO EXISTING INVERTS,APPROVAL SHALL BE OBTAINED FROM THE ARCHITECT/ENGINEER ANDTHE A.GENERAL: LETTERS AND FLOW ARROWS SHALL BE MADE BYPRODUCT STENCILS OR OIL BASED PAINT,ONE INCH HIGH AND BLACK,OR 1.INSTALL ALL PIPING,FIXTURES,EQUIPMENT,AND ACCESSORIES AS SHOWN,AND IN STRICT ACCORDANCE WITH THE PLUMBING I.THE BIDDING REQUIREMENTS,CONTACT REQUIREMENTS,AND THE GENERAL REQUIREMENTS OF THESE SPECIFICATIONS SHALL FACTORY FABRICATED PLASTIC PIPE MARKERS.PIPING SHALL BE IDENTIFIED AT 25 F00T MAXIMUM INTERVALS,ON LONG AUTHORITY HAVING JURISDICTION BEFORE ANY PIPING IS INSTALLED ATA LESSER SLOPE. LAWS,RULES,AND REGULATIONS OF THE STATE AND/OR CITY.ALL WORK SHALL BE DONE INA NEAT AND ORDERLY FASHION, GOVERN ALL PARTS OF THE WORK. CONTINUOUS LINES;ADJACENT TO EACH ITEM OF EQUIPMENT;ON EACH RISER AND JUNCTION,AND ON BOTH SIDES OF ALL 2.CONNECTIONS BETWEEN PIPING OF DISSIMILAR MATERIALS SHALL BE MADE WITH DIELECTRIC WATERWAY FITTINGS OR AND LEFT INA CONDITION SATISFACTORY TO THE ARCHITECT/ENGINEER. B.WORK INCLUDED: WALL AND FLOOR PENETRATIONS.UNDERGROUND PIPING SHALL BE IDENTIFIED WITH BRIGHT COLORED CONTINUOUSLY UNIONS. B.PIPING: PRINTED PLASTIC TAPE OF N0T LESS THAN 6"WIDE BY 4 MIL THICK,MANUFACTURED FOR DIRECT BURIAL SERVICE.INSTALL B.DOMESTIC HOTAND COLDWATER: 1.ALL PIPING SHALL BE RUN PARALLEL OR PERPENDICULAR TO ESTABLISHED BUILDING LINES.INSTALL PIPING TO ALLOW FOR 1.INSTALL WORK IN ACCORDANCE WITH THESE SPECIFICATIONS AND THE ACCOMPANYING PLANS.FURNISH ALL LABOR, DIRECTLY ABOVE ALL BURIED PIPE,6 TO 8 INCHES BELOW FINISHED GRADE.ALL PIPING SHALL BE LABELED PER THE UNIFORM MATERIALS,AND EQUIPMENT TOGETHER WITH ALL INCIDENTAL ITEMS NOT SPECIFICALLY SHOWN OR SPECIFIED WHICH ARE PLUMBING CODE,LATEST EDITION. 1.PIPING INSIDE BUILDING ABOVE SLAB OR ABOVE GRADE IN CRAWL SPACE SHALL MATCH EXISTING FROM THESE OPTIONS.IT EXPANSION.WASTE AND VENT PIPING OCCURRING ABOVE FLOOR SLAB SHALL BE INSTALLED TRUE AND PLUMB.EXTEND VENTS REQUIRED BY GOOD PRACTICE TO PROVIDE THE COMPLETE MECHANICAL SYSTEMSAS DESCRIBED. SHALL BE ASTM BEE,TYPE"L",HARD DRAWN COPPER.FITTINGS SHALL BE ANSI/ASME B16.23 CAST BRASS,0R ANSI/ASME AT LEAST I FOOTABOVE ROOF,ORTOTHE TOP OF THE CLOSESTADJACENT PARAPETWALL,WHICHEVER IS GREATER,AND 3.6 TESTING: B16.29 WROUGHT COPPER.JOINTS SHALL BE ANSI/ASTM B32 SOLDER,GRADE 95-5,LEAD FREE.CONTACTORS OPTION PROVIDE WATERTIGHT FLASHING SLEEVES.EXCAVATION AND BACKFILLSHALL BE IN ACCORDANCE WITH SECTION 2310000E 2.THE HVAC CONTRACTOR(S)AND ALL SUB-TIER CONTRACTORS SHALL PROVIDE INSTALLED EQUIPMENT CUT SHEETS AND A.PIPING: ALTERNATE MATERIALS FOR CROSS-LINKED POLYETHYLENE TUBING(PEX(:ONE PIECE PREFORMED FLEXIBLE ELASTOMERIC THESE SPECIFICATIONS. 05.06.22 PURCHASE ORDERS REQUIRED FOR UTILITY REBATES. CLOSED CELL FOAM WITH BUILT-IN VAPOR BARRIER.SEAL LAPS AND BUTT JOINTS WITH MOISTER RESISTANT ADHESIVE TO 1.ALL PLUMBING PIPING(DRAINAGE,WATER,GAS)SHALL BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OFTHE IDAHO C.FIXTURES: C.COORDINATION THISTIONANDSITHEWOS: STATE PLUMBING CODE,LATESTEDITION.OTHER PIPING SYSTEMS SHALL BE TESTED HYDROSTATICALLY,T01.5 TIMES THE PROVIDE A CONTINUOUS VAPORSEAL.INSULATION SHALL HAVE ACONDUCTIVITY RATING NOT EXCEEDING0.27 1.INSTALL FIXTURESTRUE AND PLUMB WITH BUILDING WALLS.CAULK ALL PLUMBING FIXTURES ATJOINTS ALONG WALLS, 1.THIS SECTION OFTHE WORK REQUIRES EXAMINATION OF AND REFERENCE TO ALL ARCHITECTURAL,STRUCTURAL,AND OPERATING PRESSURE,BUT N0T LESS THAN 100 PSI,FOR A MINIMUM PERIOD OF TWO HOURS.IF THETEST PRESSURE FALLS BTU-INCH/HOUR-SQ.FT:°F. COUNTERTOPS,AND OTHER INTERSECTING SURFACES.LOCATE FIXTURES AS SHOWN AND PER MANUFACTURER'S ELECTRICAL DRAWINGS FOR CONSTRUCTION CONDITIONSTHAT MAY AFFECTTHE WORK.INSPECTTHE BUILDING SITE AND M0RE THAN S PERCENT DURING THETEST PERIOD,THE LEAK SHALL BE LOCATED,REPAIRED,AND THETEST REPEATED. 2.PIPING UNDERGROUND WITHIN S FEET OF THE BUILDING LINE 0R BEL0W FL00R SLAB,SMALLERTHAN 4 INCHES,SHALL BE INSTRUCTIONS.FURNISH ALL REQUIREDTRIM FOR FIXTURESTO PROVIDE A COMPLETE AND WORKABLE INSTALLATION. EXISTING FACILITIES FOR VERIFICATION OF EXISTING CONDITIONS.BASE ALL MEASUREMENTS FROM ESTABLISHED 2.PIPING SHALLBETESTED BEFORE INSULATION HAS BEEN INSTALLED.DELICATE CONTROL MECHANISMS BE REMOVED ASTM B88,TYPE"K",HARD DRAWN OR SOFTANNEALED COPPER.FITTINGS SHALL BE ANSI/ASTM B16.29 WROUGHT COPPER. 3.2 TESTS: BENCHMARKS.ANY DISCREPANCY BETWEEN ACTUAL MEASUREMENTS AND THOSE INDICATED,WHICH PREVENTS FOLLOWING JOINTS SHALL BEANSI/ASTM 832 SOLDER,GRADE 95-5,LEAD FREE.NO JOINTS SHALL BE INSTALLED BENEATH CONCRETE GOOD PRACTICES OR THE INTENT OFTHE DRAWINGS AND SPECIFICATIONS,SHALL BE REPORTED TO THE DURING TESTS TO PREVENT SHOCK DAMAGE.THE USE OF CHEMICALS OR COMPOUNDS TO STOP LEAKS SHALL NOT BE PERMITTED. FLOOR SLABS.UNDERGROUND COPPER PIPING SHALL BE PROVIDED WITH A POLYETHYLENE JACKET,ANSI/AWWA C105,0R A.GENERAL: ARCHITECT/ENGINEER,AND WORK HALTED UNTIL INSTRUCTIONS ARE RECEIVED FROM THE ARCHITECT/ENGINEER. SHALL BE WRAPPED WITH DOUBLE LAYER,HALF-LAPPED,10 MIL POLYETHYLENE TAPE. 1.ALL PIPING,FIXTURES,AND EQUIPMENT SHALL BE INSPECTED AND APPROVED BEFORE CONCEALING OR COVERING.ALL WORK 1.2 CODES PERMITS FEES: 3.A TEST REPORT SHALL BE SUBMITTED FOR EACH PIPING SYSTEM TEST. SHALL BE TESTED AS REQUIRED BYSECTI0N 231000 OF THESE SPECIFICATIONS AND SHALL BE LEAK PROOF BEFORE 3.PIPING UNDERGROUND BEYOND 5 FEET FROM BUILDING LINE SHALL BE SCHEDULE 40 PVC,ASTM D1785 OR D2241.FITTINGS Q 4.SMOKE TEST:A SMOKE TEST SHALLBE PERFORMED ON THE WASTE AND VENT SYSTEM BEFORE BUILDING OCCUPANCY.AFTER INSPECTION IS REQUESTED.ALL TESTS SHALL BE REPEATED IF REQUIRED BY THOSE MAKING THE INSPECTION. A.INSTALL ALL WORK IN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS.OBTAIN ALL REQUIRED PERMITS;PAY ALL REQUIRED SHALL BE PVC,ANSI/ASTM D2466.JOINTS SHALL BE SOLVENT W ELD,ASTM D 2855,OR GASKETED,ASTM f477.PIPING SHALLBE FEES INCLUDING UCATESOONNECTIONNS FORTHEWOS,IN CONNECTION WITH THIS PORTION OFTHE CONSTRUCTION.OBTAIN ALL WITHSMOKE UNAULFIXTURESAR ER PRESS REOF1TLY NN1 INCHTED ANDTRAPSAREFIA SMOKTHWATER,FIFLEAKSARENTIRE DETECTED,T EY SHALL EM RATED FOR N0T LESS THAN 150 PSIG PRESSURE. 2.ALL POTABLE WATER SYSTEMSSHALL BE FLUSHEDAND DISINFECTED IN ACC0RDANCEWITH SECTION 231000OFTHESE REQUIRED CERTIFICATES OF INSPECTIONS FORTHE WORK. WITH SMOKEUNDERPRESSURE OF AL BINCHOFWATER)WITHASMOKEMACHINE.IFLEAKS ARE DETECTED,THEY SHALL BE SPECIFICATIONS.FOLLOWING DISINFECTION,SYSTEM SHALL BE FLUSHED AND WATER SAMPLES TO SHOW COMPLIANCE WITH REPAIRED AND THE SMOKE TEST SHALL BE PERFORMED AGAIN UNTIL NO LEAK IS FOUND. C.STANDARD SANITARY SEWER AND VENT: PART 2-PRODUCTS REQUIREMENTS OF PUBLIC HEALTH AUTHORITY HAVING JURISDICTION.IF TESTED WATER DOES NOT MEET REQUIREMENTS, B.SYSTEM: 1.PIPING AND FITTINGS SHALL BE SCHEDULE 40 PVC-DWV(CELLULAR CORE),PER ASTM F1488 AND ASTM F891,SOLVENT DISINFECTING SHALL BE REPEATED UNTIL WATER QUALITY MEETS REQUIREMENTS. 2.1 MATERIALS AND WORKMANSHIP 1.ALL SYSTEMS,INCLUDING HEATING,VENTILATING,AIR CONDITIONING,AND PLUMBING SYSTEMS,SHALL BE TESTED AT THE WELDED PER SOLVENT MANUFACTURER'S INSTRUCTIONS,0R ABS SCHEDULE 40 PIPING AND FITTINGS PER EITHER ASTM D2661 B.FIXTURESAND EQUIPMENT: A.MATERIALS COMPLETION OF THE BUILDING TO ESTABLISH THATTHE SYSTEMS OPERATE AS SPECIFIED AND REQUIRED.TESTING SHALL BE 0RASTM F628 WITH SOLVENT CEMENT CONFORMING TO ASTM D2235.ALL PIPING PENETRATIONS THROUGH FIRE RATED PERFORMED WATER BALANCING ISCOMPLETED. WALLS,FLOORS,OR CEILINGS,AND ALL PIPING LOCATED ABOVE CEILINGS USED AS RETURN AIR PLENUMS SHALLALSO BE CAST 1.FILL ALL PLUMBING FIXTURES WITH WATER AND CHECK FOR LEAKS OR RETARDED FLOW.REPAIR AS REQUIRED.ADJUST EACH 1.ALL MATERIALS AND EQUIPMENT SHALL BE OF FIRST QUALITY,NEW,FULL SIZE AND WEIGHT,STANDARD IN EVERY RESPECT, IRON OR GALVANIZED STEEL,ASTM A53.UNDERGR0UND PVC-DWV PIPING SHALL BE INSTALLED PER ASTM D-2321.MATCH PIECE OF PLUMBING EQUIPMENT AS REQUIRED TO INSURE PROPER FUNCTIONING.LEAVE ALL FIXTURES AND EQUIPMENT IN AND SUITABLE FOR THE SPACE REQUIRED.USE THE SAME MANUFACTURER FOR PRODUCTS OF SIMILAR CLASS OR SERVICE, 2.ALL CONTROLS SHALL BE CALIBRATED ACCURATELY AND ALL EQUIPMENT SHALL BE ADJUSTED FOR SATISFACTORY OPERATION. EXISTING PIPING MATERIALS.FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID. FIRST CLASS OPERATING CONDITION. SUCH AS VALVES,CONTROLS,AND FANS.PROTECT ALL MATERIALS AGAINST LOSS,THEFT,OR DAMAGE BEFORE AND AFTER EXCESSIVE VIBRATION OR NOISE FROM ANY SYSTEM SHALL BE CORRECTED. INSTALLATION. 2.ALL 90 DEGREE WASTE LINE ELBOWS SHALL BE PER THE LATEST ISSUE OF THE IDAHO STATE PLUMBING CODE,LATEST EDITION. 2.THE PLUMBING CONTRACTOR IS RESPONSIBLE FOR ALL BACKFLOW DEVICES TO BE INSPECTED BY A CERTIFIED BACKFLOW 2.FURNISH EQUIPMENT THAT WILL OPERATE UNDER ALL CONDITIONS OF LOAD WITHOUT ANY SOUND OR VIBRATION THAT IS 3.7 BALANCING 3.ALL UNDERGROUND KITCHEN SANITARY AND EXPOSED VENT PIPING LOCATED IN OCCUPIED AREAS OR ROOMS,IS TO 8E CAST TECHNICIAN BEFORE THE USE OF THE BUILDING POTABLE WATER SYSTEM. OBJECTIONABLE IN THE OPINION OF THE ARCHITECT/ENGINEER.VIBRATION OR NOISE CONSIDERED OBJECTIONABLE WILL BE A.SCOPE: IRON WITH CAST IRON FITTINGS. END OF SECTION 220000 0 CORRECTED BY THE SUBCONTRACTOR AT HIS EXPENSE. 1.PRIOR TO FINAL ACCEPTANCE BY THE OWNERS,ALL AIR SYSTEMS SHALL BE BALANCED TO DELIVER THE QUANTITIES AS 4.CLEANOUTS SHALL BE PROVIDED AT EACH HORIZONTAL DRAINAGE PIPE AT ITS UPPER TERMINAL,AND EACH RUN OF PIPING 3.FURNISH AND INSTALL ALL NECESSARY FOUNDATIONS,SUPPORTS,PADS,BASES,AND PIERS REQUIRED FOR ALL MATERIALS SPECIFIED OR DIRECTED.THE AIR BALANCE SHALL BE PERFORMED BY AN INDEPENDENT AGENCY SPECIALIZING IN TESTING, WHICH IS M0RE THAN 100 FEET,AND SHALL BE PROVIDED FOR EACH 100 FEET DEVELOPED LENGTH,OR FRACTION THEREOF OF SECTION 23 0000-HEATING,VENTILATING,AND AIR CONDITIONING a AND EQUIPMENT FURNISHED UNDER THIS CONTRACT. ADJUSTING,AND BALANCING,AND IS CERTIFIED BY THE TESTING,ADJUSTING,AND BALANCING BUREAU(TABS),AND THE SUCH PIPING.AN ADDITIONAL CLEAN OUT SHALL BE PROVIDED FOR EACH AGGREGATE HORIZONTAL CHANGE OF DIRECTION NATION AL ENVIRONMENTAL BALANCING BUREAU(NEBB).TOTAL SYSTEM BALANCE SHALL BE IN ACCORDANCE WITH TABB. EXCEEDING ONE HUNDRED THIRTY-FIVE DEGREES,PER APPLICABLE PLUMBING CODE.THIS SHALL BE PROVIDEDREGARDLESS OF PART1-GENERAL U) 4.PROVIDE ALL REQUIRED FIRE STOPPING AT PIPING AND DUCT PENETRATIONS OF FIRE RATED WALLS,FLOORS,CEILINGS,AND WHAT IS SHOWN ON THE DRAWINGS. 1.1 SCOPE: ROOFS.FIRE STOPPING SHALL BE DOW CORNING FIRE STOP SEALANT 2000 OR FIRE STOP FOAM 2001,OR APPROVED EQUAL. B.AIR BALANCING z 1.BALANCING OF THE AIR SYSTEM SHALL CONSIST OF: S.ALL VENTS THROUGH ROOF(VTR'S)SHALL BE EXTENDED AT LEAST I FOOT ABOVE THE ROOF SURFACE,OR TO THE TOP OF THE A.THIS SECTION COVERS THE WORK NECESSARY FOR THE HEATING,VENTILATING,AND AIR CONDITIONING SYSTEM,COMPLETE.THE O B.WORKMANSHIP: CLOSEST ADJACENT PARAPET WALL,WHICHEVER IS GREATEST. MECHANICAL GENERAL PROVISIONS,SECTION 231000,IS TO BE INCLUDED AS A PART OF THIS SECTION OF THE SPECIFICATIONS. 1.ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER BY COMPETENT SPECIALISTS a.ADJUST ALL AIR VOLUMES,INCLUDING OUTSIDE AIR,TO THE QUANTITIES SHOWN,WITH ALLOWABLE VARIATION OF PLUS 10,MINUS 10 PERCENT. E.NATURALGAS: 1.2 CODES&STANDARDS FOREACHCTORYSUB WORK E.WORK BE REINSTALLESTALLED TO D O SATISFACTION OF AT NOEXTRARCHITECT/ENGINEEROSTTTHWITH 1.PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE,ASTM A53.EXP0SED FITTINGS 2 INCHES AND SMALLER SHALL BE ANSI/ASME A.THE HEATING,VENTILATING,AND AIR CONDITIONING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF Q UNSATISFACTORY WORK REMOVED AND REINSTALLED TO HIS SATISFACTION AT NO EXTRA COST TO THE OWNER. b.RECORD ALL SYSTEM DIFFUSER,GRILLE,AND REGISTER CFM.USE VOLUME CONTROL DEVICES TO REGULATE AIR U 2.PROVIDE ALL CUTTING AND PATCHING NECESSARY TO INSTALL THE WORK SPECIFIED IN THIS SECTION.PATCHING SHALL MATCH QUANTITIES ONLY TO THE EXTENT THAT ADJUSTMENTS DO NOT CREATE OBJECTIONABLE AIR MOTION OR SOUND B16.3,SCREWED,BLACK MALLEABLE IRON. THE FOLLOWING CODES AND STANDARDS: ADJACENT SURFACES.NO STRUCTURAL MEMBERS SHALL BE CUT WITHOUT THE APPROVAL OF THE ARCHITECT/ENGINEER. LEVELS. 2.FITTINGS LARGER THAN 21NCHE5 AND ALL UNDERGROUND FITTINGS SHALL BE SCHEDULE 40 STEEL BUTT-WELDED TYPE. 1.INTERNATIONAL MECHANICAL CODE(IMC) LL PROVIDE ALL SLEEVES AND INSERTS REQUIRED BEFORE THE FLOORS AND WALLS ARE BUILT. c.TEST AND RECORD ALL SYSTEM STATIC PRESSURES,INLET AND DISCHARGE,ON ALL FANS.VARY TOTAL SYSTEM AIR UNDERGROUND PIPING SHALL BE PROVIDED WITH A POLYETHYLENE IACKET,ANSI/AWWA C105,0R SHALL BE WRAPPED WITH 2.INTERNATIONAL BUILDING CODE(IBC) U 3.LOCATE ALL EQUIPMENT THAT MUST BE SERVICED IN FULLY ACCESSIBLE POSITIONS.PROVIDE CLEARANCE FOR REMOVAL OR QUANTITIES BY ADJUSTMENT OF FAN SPEEDS.PROVIDE DRIVE CHANGES AS NECESSARY.VARY BRANCH AIR QUANTITIES DOUBLE LAVER,HALF-LAPPED,10 MIL POLYETHYLENE TAPE. LLI BY DAMPER REGULATION. 3.ALL EXTERIOR PIPING EXPOSED TO THE WEATHER SHALL BE COATED WITH A RUST INHIBITOR-RUST0LEUM#866 PRO-GUARD 3.AMERICAN SOCIETY OF HEATING,REFRIGERATION,AND AIR CONDITIONING ENGINEERS(ASHRAE( LL REPLACEMENT PARTS AND COMPONENTS,AND WITH NECESSARY COUPLINGS OR FLANGES TO REMOVE THE COMPONENT FOR U) MAINTENANCE. d.TEST AND RECORD MOTOR FULL LOAD AMPS AND NAMEPLATE AMPS. PRIMER-RED OR GRAY COLOR-OR APPROVED EQUAL. 4.NATIONAL FIRE PROTECTION ASSOCIATION(NFPA) �T� 4.ALL ROOF WORK SHALL MEET THE REQUIREMENTS OF THE MANUFACTURER TO MAINTAIN THE WARRANTY. 3.8 CLEANING AND ADJUSTING: F.HANGER AND SUPPORTS: S.SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION,INC.(SMACNA) V 2.2 SUBMITTALS AND SUBSTITUTIONS: A.THOROUGHLY CLEAN ALL PARTS OF THE SYSTEM AT THE COMPLETION OF THE WORK.ADJUST ALL DEVISES FOR PROPER OPERATION 1.PIPE HANGERS SHALL BE PROVIDED TO ADEQUATELY SUPPORT ALL PIPING SYSTEMS.HANGERS SHALL BE VERTICALLY PART 2-PRODUCTS z A.PR AND LUBRICATE ALL EQUIPMENT AS REQUIRED.REPAINT ANY PAINTED SURFACE THAT HAS BEEN DAMAGED. ADJUSTABLE TO PROVIDE FOR PROPER PITCH AND DRAINAGE.HANGERS SHALL ALLOW FOR EXPANSION AND CONTRACTION OF 2.1 EXHAUST FANS 1.MANUFACTUAPPROVAL: m URER'STRADE NAMES AND CATALOG NUMBERS STATED HEREIN ARE INTENDED TO INDICATE THE QUALITY OF B.ALL POTABLE WATER SYSTEMS SHALL BE FLUSHED AND DISINFECTED AFTER TESTS ARE COMPLETED.DISINFECTION SHALL BE IN THE PIPING SYSTEM.REFERENCE"GENERAL REGULATIONS"OF THE LATEST EDITION OF THE IDAHO STATE PLUMBING CODE. A.SEE PLANS FOR REQUIREMENTS. O ACCORDANCE WITH LOCAL MUNICIPAL AND STATE PLUMBING INSPECTOR'S CRITERIA.IN LIEU OF SUCH CRITERIA,THE FOLLOWING 2.HANGERS FOR PIPE SIZES%TO 6 INCHES SHALL BE ADJUSTABLE CLEVIS TYPE,OR UNISTRUT SADDLES WITH ALL-THREAD LL EQUIPMENTMA INCLUSNGSED.ALLMANS,OF THEROOSEDEQUIPLLYTTOT LISTED REQUIREPCT/ENGINEERRIOR F SUBMIT HANGERROD. 2.2 AIR DISTRIBUTION z p J CATALOG DATA,INCLUDING SPECIFICATIONS,OFTHE PROPOSED EQUIPMENT TO THE ARCHITECT/ENGINEER FOR APPROVAL AT PROCEDURE SHALL BE FOLLOWED FOR DISINFECTION: 1.COMPLETELY FLUSH SYSTEM.ADDALKAU OR ACID TO BRING WATER PH LEVEL BETWEEN 7.4 AND 7.6. 3.VERTICAL PIPES SHALL BE SUPPORTED WITH STEEL RISER CLAMPS.SPACING INTERVAL REQUIREMENTS PER"GENERAL A.DUCTWORK: J O_ LEASTS BUSINESS DAYS PRIOR TO BID OPENING.NOTICE OF SUCH APPROVALS WILL BE PUBLISHED IN AN ADDENDUM. (HYDROCHLORIC) 0 APPROVAL OF LISTED ALTERNATE EQUIPMENT MANUFACTURERS IS FOR BIDDING ONLY.FINALAPPROVAL ISTO BE BASED ON REGULATIONS"OF THE LATEST EDITION OFTHE IDAHO STATE PLUMBING CODE. 1.LOW PRESSURE DUCTWORK SHALL BE FABRICATED FROM GALVANIZED SHEET METAL,UNLESS OTHERWISE INDICATED. - u 2.INJECT CHLORINE(LIQUID,POWDER,TABLET,OR GAS)THROUGHOUT THE SYSTEM TO 0BTAIN SO TO 80 MG/L RESIDUAL. CONSTRUCTION REQUIREMENTS SHALL BE IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS,METAL 06 REQUIREMENTS OF THE PLANS AND SPECIFICATIONS. 4.ALL INSULATED PIPING SHALL BE PROVIDED WITHAND OVEUMIBGAUGE GALVANIZED INSULATION LONG Z J 3.BLEED WATER FROM OUTLETS TO ENSURE DISTRIBUTION,ANDTEST FOR RESIDUAL ATA MINIMUM OF IS PERCENT OF THE AND OVERSIZED HANGERS.PIPE SIZES 2INCHES AND OVER SHALL ALSO BE PROVIDED WITH 121NCH LONG CALCIUM SILICATE AND FLEXIBLE,LATEST EDITION.ALLSHEET METAL DUCTWORK SHALL BE SEALED WITH MCGILL UNITED SHEET DUCTSEALER OR Q 22 B.SUBMITTALS: OUTLETS. INSULATING BLOCKS BETWEENTHE PIPING AND THE GALVANIZED INSULATION SHIELD. EQUAL,IN ACCORDANCEWITH THE INTERNATIONAL ENERGY COMPLIANCE CODE,LATEST EDITION.LOW PRESSURE DUCTWORK N F Q 1.WITHIN THIRTY DAYS AFTER AWARD OF THIS CONTRACT,PROVIDEAN ELECTRONIC COPY OF A COMPLETE USTOFALL 4.MAINTAIN DISINFECTION IN SYSTEM FOR 24 HOURS. z SHALL BE CONSTRUCTED TO THE FOLLOWING SMACNA STATIC PRESSURE STANDARDS: o _U MATERIALS AND EQUIPMENT PROPOSED FOR THIS PROJECT.LIST SHALL CONTAIN MAKE,TYPE,MANUFACTURER'S NAME,AND S.HANGER ROD SIZING AND SPACING FOR PIPE SHALL BE AS FOLLOWS: TRADE DESIGNATION OF ALL MATERIALS AND EQUIPMENT.SUBMITTAL SHALL ALSO INCLUDE MANUFACTURER'S COMPLETE S.IF FINAL DISINFECTANT RESIDUAL TESTS LESS THAN 25 MG/L,REPEAT TREATMENT. PIPE SIZE MINIMUM ROD DIAMETER MAXIMUM SPACING a.SUPPLY AIR DUCTWORK=2"W.G. Ltd = Z SPECIFICATION FOR EACH ITEM,INCLUDING CAPACITIES,RATINGS,ETC.,AND DIMENSIONS AS REQUIRED TO CHECK SPACE 6.FLUSH DISINFECTANT FROM SYSTEM UNTIL RESIDUAL IS EQUAL TO THAT OF INCOMING WATER,OR 1.0 MG/L. TO 1-1/4 INCHES 3/8 INCH 6.5 FEET b.RETURN,EXHAUST,OUTSIDE AIR INTAKE DUCTWORK=1"W.G. LLI W w Q REQUIREMENTS.THE SCHEDULED EQUIPMENT IS THE BASIS OF DESIGN FOR CAPACITY,WEIGHTS,PHYSICAL SIZE,ETC. TO 2INCHES 3/81NCH 10 FEET 2.DUCTWORK PENETRATING PROTECTIVE ELEMENTS OF FIRE-RATED CORRIDOR WALLS,WITH NO OPENINGS INTO CORRIDOR, 00 ALTERNATEMANUFACTURERS SHALL NOT EXCEED THE WEIGHT OR PHYSICAL SIZE.ANY CHANGES TO THE ARCHITECTURAL, 7.WAKESAMPLES N0 SOONER THAN 24 HOURS AFTER FLUSHING,FROM 10 PERCENT OF THE OUTLETS AND THE INCOMING TO3INCHES 1/21NCH 10 FEET SHALLBEC0NSTRUCTED OF MINIMUM 26 GAUGE GALVANIZED STEEL. Q F-- S U STRUCTURAL,MECHANICAL,ELECTRICAL,AND CONTROL SYSTEMS DUE TO ALTERNATE MANUFACTURERS SHALL BE THE 2i � w LLI T06INCHES 5/8INCH 10 FEET B.DUCT ACCESSORIES: n G REVIEW OF I THE SHALL NOT RANVE THE TER. 3.9 PR0lECT CL05E0UT: PVC&ABS(ALL SIZES) 3/8 INCH 4FEET 1.FLEXIBLE CONNECTIONS SHALL BE PROVIDED AT ALL ROTATING FAN EQUIPMENT.CONNECTORS SHALL BE OF FIRE,WATER, Q LLJ G 2.REVIEW OF SUBMITTALS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM THE PLANS OR A.OPERATIONS&MAINTENANCE MANUAL: SPECIFICATIONS,UNLESS HE HAS,IN WRITING,CALLED THE ARCHITECT/ENGINEER'S ATTENTION TO DEVIATIONS AT THE TIME CASTIDE HANGRON HUB 512INCH SFZONTALEET AND LBOW.T5 AND WEATHER RESISTANT MATERIAL. OF SUBMISSION,AND OBTAINED HIS WRITTEN APPROVAL.APPROVAL OF SUBMITTALS DOES NOT RELIEVE THE CONTRACTOR THE CONTRAROR SHALL PROVIDE AN OPERATIONS AND MAINTENANCE MANUAL AT LEAST THIRTY DAYS PRIOR TO 6.PROVIDE HANGERS WITHIN 121NCHE50F EACH HORIZONTAL ELBOW. C.DIFFUSERS,REGISTERS,LOUVERS,GRILLES,WEATHERCAPS: FROM RESPONSIBILITY FOR ERRORS IN SHOP DRAWINGS OR LITERATURE. COMPLETION OF WORK.THE MANUAL SHALL BE OF THE THREE RING BINDER TYPE,ENTITLED"OPERATIONS AND 7.PROVIDE HANGERS WITH MINIMUM 1-1/2 INCHES VERTICAL ADJUSTMENTS MAINTENANCE MANUAL",WITH THE JOB NAME AND YEAR OF COMPLETION ALSO INCLUDED.THE MANUAL SHALL INCLUDE,AS . 1.SEE PLANS FOR REQUIREMENTS. C.EQUIPMENT REQUIRING SUBMITTALS AMINIMUM: 2.3 INSULATION: 2.3 CONTROLSVSTEM 1.EXHAUST FANS,ENERGY RECOVERY VENTILATION UNITS,ELECTRIC HEATERS,SPLIT SYSTEM HEAT PUMPS 1.MAINTENANCE INSTRUCTIONS FOR ALL EQUIPMENT,INCLUDING LUBRICATION REQUIREMENTS. A.GENERAL A.GENERAL: 2.GRILLES,REGISTERS,DIFFUSERS,LOUVERS,WALL CAPS 2.EQUIPMENT START-UP REPORTS. 1.ALL INSULATION SHALL HAVE COMPOSITE FIRE AND SMOKE HAZARD RATINGS,AS TESTED BYASTM E-84,NFPA 255,AND UL 1.THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR A COMPLETE AND OPERABLE CONTROL SYSTEM,INCLUDING 3.WATER HEATERS,PLUMBING FIXTURES AND TRIM 3.EQUIPMENT SUPPLIERS NAMES,ADDRESSES,AND TELEPHONE NUMBERS. 723,NOT EXCEEDING A FLAME SPREAD OF 25 AND SMOKE DEVELOPED OF 50. EQUIPMENT,INSTALLATION,AND ACCESSORIES REQUIRED TO PERFORM THE REQUIRED CONTROL FUNCTIONS.ALL CONTROL PART 3 EXECUTION 4.EQUIPMENT CATALOG CUTS,RATINGS TABLES,MODEL NUMBERS,SERIAL NUMBERS,AND ACCESSORIES. B.PIPING: CONDUIT AND WIRING SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR.TIMERS,SUB-BASE SWITCHES,REMOTE 1 ALL COPPER DOMESTIC,POTABLE&NON-POTABLE,HOT AND COLD WATER LINES SHALL BE INSULATED WITH PREFORMED CONTROL DEVICES,ETC.,SHALL BESUPPLIED BVTHE MECHANICAL CONTRACTOR AND INSTALLED AND CONNECTED BVTHE . 3.1 ACCESSIBILITY&SAFETY S.PARTS NUMBERS FOR ALL REPLACEABLE PARTS. MECHANICAL CONTRACTOR.THE MECHANICAL CONTRACTOR SHALL FURNISH THE ELECTRICAL CONTRACTOR WITH WIRING INSULATION.A.ACCESSIBILITY: 6.AIR SYSTEMS BALANCE REPORT AS HEREINBEFORE SPECIFIED. DIAGRAMS FOR ALL MECHANICAL EQUIPMENT AND CONTROLS. a.FIBERGLASS INSULATION WITH AVAP0R BARRIERJACKET.INSULATION SHALL HAVE ACONDUCTIVITY NOT EXCEEDING 2.THE CONTROL SYSTEM SHALL BE BASICALLY ELECTRIC,WITH SUPPLEMENTARY ELECTRONIC DEVICESAS REQUIRED. 1.ALL EQUIPMENT WHICH MUST BE SERVICED OR OPERATED SHALL BE LOCATED IN FULLY ACCESSIBLE POSITION.MINOR 7.GUARANTEE LETTER AS SPECIFIED BELOW. 0.28 BTU-INCH/HOUR-SQ.FT:°F.LAPS AND BUTT JOINTS SHALL BE SEALED WITH PRESSURE SENSITIVE JOINT SEALING PRIOR TO ACCTUALTUAL INSTALLATION. CHANGES EDRAWINGS MAYBE MADE TO ALLOW FOR BETTER ACCESSIBILITY.ALL CHANGES SHALL BE APPROVED B.ANY ADDITIONAL INFORMATION REQUIRED TO ENABLE THE OWNER TO PROPERLY MAINTAIN THE BUILDING MECHANICAL TAPE OF THE SAME FINISH AS THE INSULATION JACKET TO PROVIDE A CONTINUOUS VAPOR SEAL.FITTINGS AND VALVES 3.TIMERS: U SYSTEM. SHALL BE INSULATED WITH PVC FITTING COVERS AND FIBERGLASS INSULATION INSERTS,OR WITH HYDRAULIC SETTING a.TIMERS SHALL BE 7-DAY PROGRAMMABLE TYPE,WITH MANUAL OVERRIDE. 2.ACCESS PANELS SHALL BE PROVIDED IF REQUIRED FOR ACCESSIBILITY.SUBCONTRACTOR SHALL FURNISH THE REQUIRED PANELS 9,AFT ER APPROVAL OFTHE OPERATIONS AND MAINTENANCE MANUAL BY THEARCHITER/ENGINEER,THE CONTRACTOR SHALL INSULATINGCEMENT AND FOUR OUNCE CANVAS JACKET WITH VAPOR BARRIER ADHESIVE. b.ALL TIMERSSHALL HAVE AM0UNTING HEIGHT OF 461 NCH E5,TO THE CENTERLINE OFTHE DEVICE,UNLESS OTHERWISE TOTHE GENERAL CONTRACTOR AND THE REQUIRED LOCATION FOR ALL ACCESS PANELS.PANELS SHALL BE INSTALLED BY THE GENERAL CONTRACTOR. FURNISH TWO COPIES OF THE MANUAL TO THE OWNER.ALSO PROVIDE AN ELECTRONIC PDF COPY OF THE O&M MANUAL ON INSULATION THICKNESS SHALL BE AS FOLLOWS: NOTED ON THE ELECTRICAL DRAWINGS. B.SAFETY: A THUMB DRIVE. SYSTEM PIPE SIZES%"AND ABOVE PART 3-EXECUTION V o r+ 1.SUBCONTRACTORB.MECHANICAL SYSTEM TRAINING PERIOD:OR SHALL PROVIDE GUARDS FOR ALL BELT DRIVES AND ROTATING MACHINERY.NO WATER PIPING SHALL RUN DOMESTIC COLD WATER(POT.&NON-POT.) %" 3.1 WORKMANSHIP: 1.AFTER THE MECHANICAL SYSTEM IS COMPLETELY INSTALLED AND OPERATIONAL,THE MECHANICAL CONTACTOR SHALL DOMESTIC HOT WATER&RECIRC.(POT.&NON-POT. 1" � IMMEDIATELY OVER OR WITHIN A 3-FOOT PLAN VIEW CLEARANCE OF ANY ELECTRICAL PANEL N MOTOR STARTER.WHERE ) A.GENERAL: PROVIDER MINIMUM OF HOUR TRAINING AND INSTRUCTION TIME FOR THE BUILDING OWNER OR HIS REPRESENTATIVE. PIPING MUST BE LOCATED WITHIN ZONES,INSTALL PIPINGINSIDEAC0NDUITT0 PREVENTWATERACCE55 TO DURINGTHIS PERIOD,THE CONTRACTOR SHALL INSTRUCT THE OWNER IN THE OPERATION AND MAINTENANCE OFALL PARTS 2.INSULATION SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. 1.INSTALL ALL MATERIALS AND EQUIPMENT AS SHOWN AND IN STRICT ACCORDANCE WITH THEAPPLICABLE CODES FORTHE Qy�� ELECTRICAL EQUIPMENT, OFTHE MECHANICAL SYSTEM,USINGTHE O&M MANUAL WHERE APPLICABLE. 3.INSULATION SHALL BE CONTINUOUS THROUGH PENETRATIONS. STATE AND/OR CITY.PLANS DO NOT ATTEMPTTO SHOW EXACT DETAILS OF ALL PIPING AND DUCTWORK,AND NO EXTRA 3.2 COORDINATION: PAYMENT WILL BE ALLOWED FOR OFFSETS REQUIRED DUE TO OBSTRUCTIONS BY OTHER TRADES.ALL WORK SHALL BE DONE IN wS w CAS-BUILT-DRAWINGS: 4.ALLINSULATION SHALLBE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. A NEATAND ORDERLY FASHIONAND LEFT IN A CONDITION SATISFACTORY TO THE ARCHITECT/ENGINEER. � o A.COORDINATEALL WORKOF ,DUCIFITH WORK,EVARIOD TRADESINTAREDTOPROWN.NO COMPLETE COMPENSATIONORY INSTALLATION.THE 1.PROVIDE TW0 SETS OF BLUE-LINE MECHANICAL DRAWINGS SHOWING THE WORK AS IT WAS ACTUALLY INSTALLED.THE 2.4 VALVES AND STRAINERS EFFSETS TAILSLOCATIONREQIREDIN ANDDINATIENWITH OTHERNOTS TAD NO ADDITIONAL COMPENSATION WILL BE MADE FORAA 2.EXPANSIONALL PIPING. INSTALHALL BEL RUN PARALLELWITH RTO OR ESTABLISHED BUILDING AIR LINESATALLLPIPINGTTS.PRO FOR U U x UTILI S WITH DIMENSIONS IONSFR MEET FROM THE BUILDING IN S.MAKE ALL NO SHALL LOCATE ALL UNDERGROUND EXPANSION.INSTALL ALL VALVES WITH STEMS HORIZONTAL OR ABOVE.INSTALL AIR VENTS AT ALL HIGH POINTS.PROVIDE ALL �� N OFFSETS OR RELOCATION REQUIRED INCOORDINATION WITH OTHER TRADES. A.BALL VALVES: UTIELI LINESEWITHDIME COMP FROM OF THE WORK, SHED THESE ALINES.DRAWINGS SHALL NEAT AND LEGIBLE,WITH RED PIPING WHICH PASSES THROUGH WALLS, OR CEILINGS WITH STANDARD WEIGHT PIPE SLEEVES. B.ALTERATIONS REQUIRED DUE TO IMPROPER SUPERVISION BY THE SUBCONTRACTOR SHALL BE MADE AT NO EXTRA COST,TO THE INDELIBLE PENCIL.AT THE COMPLETION OFTHE WORK,THESEAS-BUILTDRAWINGSSHALL BE SIGNED AND DATED BY THE 1.VALVES 2-INCHES AND SMALLER SHALL BE CAST BRASS BODY,CHROME-PLATED BRASS BALL TEFL0N SEATS,AND LEVER � WWh SATISFACTION OF THE ARCHITECT/ENGINEER. MECHANICAL CONTRACTOR,AND RETURNED TO THE ARCHITECT/ENGINEER. HANDLE,600 PSI CWP.VALVES SHALL COMPLY WITH MSS SP-110.VALVES OVER 2-INCHES SHALL BE DUCTILE IRON OR CAST B.DIFFUSERS,REGISTERSAND GRILLES: STEEL BODY,CHROME PLATED STEEL BALL,TEFLON SEATS,AND LEVER HANDLE.VICTAULIC SERIES 726,ANVIL GRUVLOK, 3.3 ELECTRICAL: D.GUARANTEE: GRIN NELL,0RSHUR1OINT BALL VALVES ARE ACCEPTABLE IF GROOVED PIPING IS USED. 1.ALL DIFFUSERS,GRILLES,AND REGISTERS SHALL BE INSTALLED TIGHT ON THEIR RESPECTIVE MOUNTING SURFACES AND SHALL rl A.ELECTRIC MOTORS REQUIRED FOR EQUIPMENT SPECIFIED IN THIS SECTION SHALL BE PROVIDED AND INSTALLED BY THIS 1.ALL WORK FURNISHED UNDER THIS SECTION SHALL BE GUARANTEED IN WRITING BE FREE FROM DEFECTIVE WORK BE ACCURATELY CENTERED ON CEILING TILE,RECESSES,WINDOWS,OR DOORS. V SUBCONTRACTOR.M0T0R STARTERS,DISCONNECTS,RELAYS,PILOT LIGHTS,ETC.,ARE IN GENERAL TO BE FURNISHED AND MATERIALS FORA PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE CONTRACT.ALLLL REPAIRS OR REPLACEMENTS BECAUSE OF C.DUCTWORK: INSTALLED BY THE ELECTRICAL CONTRACTOR. DEFECTIVE MATERIALS OR WORKMANSHIP OR NONCOMPLIANCE WITH CODE SHALLBE PROVIDED WITHOUT ADDITIONAL COST 1.ALL SHEET METAL WORK SHALL BE DONE BY QUALIFIED,EXPERIENCED MECHANICS IN ACCORDANCE WITH THE REQUIREMENTS WJ B.STARTERS,RELAYS,CONTROLS,ETC.,WHICH ARE FACTORY ASSEMBLED INTO PACKAGED EQUIPMENT SHALL BE FURNISHED BY THE TO THE OWNER.CONTRACTOR SHALL FURNISH A LETTER INDICATING ABOVE GUARANTEE WITH SPACE FOR DATE OF OF ASHRAE AND THE LATEST EDITION OF THE APPLICABLE SMACNA MANUAL.ALL DUCTWORK SHALL BE INSTALLED IN A NEAT MECHANICAL CONTRACTOR UNDER THIS SECTION OF THE SPECIFICATIONS. ACCEPTANCE AND EXPIRATION OF GUARANTEE.LETTER SHALL BE INCLUDED IN 0&M MANUAL. AND ORDERLY MANNER,AND SHALL BE ADEQUATELY SUPPORTED TO PREVENT VIBRATION OR SAGGING.ALL SHEET METAL C.ALL MOTORS SHALL BE PROVIDED WITH ADEQUATE STARTING AND PROTECTIVE EQUIPMENT AS SPECIFIED OR REQUIRED.MOTOR END OF SECTION 231000 DUCTWORK SHALL BE SEALED WITH UNITED-SHEET METAL DUCT SEALER OR EQUAL. CAPACITY SHALL BE SUFFICIENT TO OPERATE DRIVEN DEVICE UNDER ALL CONDITIONS OF OPERATION AND LOAD WITHOUT SECTION 22 0000-PLUMBING END OF SECTION 230000 OVERLOAD.MINIMUM HORSEPOWER SHALL BE SPECIFIED. PART 1-GENERAL 3.4 EXCAVATION&BACKFILL 1.1 SCOPE: A.EXCAVATE TRENCHES REQUIRED FOR UNDERGROUND PIPING TO PROPER ELEVATION AND GRADE.PROVIDE TRENCHES WITH SOLID A.THIS SECTION COVERS THE WORK NECESSARY FOR THE PLUMBING SYSTEM,COMPLETE.THE MECHANICAL GENERAL PROVISIONS, BOTTOMS TO ALL OW SUPPORT OF PIPING ALONG ENTIRE LENGTH WITH EXCAVATION AT BELLS AS REQUIRED FOR JOINTING AND SECTION 231000 ARE TO BE INCLUDED ASA PART OF THIS SECTION OF THE SPECIFICATIONS. INSPECTION.PROVIDE REPAIRING OF FINISHED SURFACES,AND ALL REQUIRED SHORING,BRACING,PUMPING,AND PROTECTION FOR SAFETY OF PERSONS AND PROPERTY.OBSERVE ALL LOCAL OR STATE SAFETY CODES.VERIFY THAT ELEVATIONS OF EXISTING UTILITIES 1.2 CODES: WILL ALLOW FOR PROPER GRADING OF PIPING CONNECTING TO EXISTING UTILITIES. A.THE PLUMBING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE IDAHO STATE PLUMBING CODE,LATEST EDITION, B.EXCAVATION AND BACKFILL SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF DIVISION 2-SITEWORK,OF THESE INTERNATIONAL FUEL GAS CODE,LATEST EDITION;AND ALL LOCAL AND STATE CODES. SPECIFICATIONS. 1.3 FIXTURES&EQUIPMENT ® Engineered DATE: 11/13/2023 3.5 IDENTIFICATION AND CODING: A.GENERAL: SSJONAL F4,C SVStems A.PAINTING: IH 1.PLUMBING FIXTURES AND EQUIPMENT SHALL BE LISTED ON THE DRAWINGS,OR APPROVED EQUALS. F� 15 RF/�F` ASSUCIiltes 1.ALL PAINTING OF MECHANICAL EQUIPMENT,ACCESSORIES,DUCTWORK,AND PIPING SHALL BE FURNISHED AND APPLIED CITY APPROVED PLANS UNDER THE ARCHITECTURAL SECTION OF THESE SPECIFICATIONS.ALL PAINTING SHALL BE COMPLETED BEFORE ANY PART2-PRODUCTS 1ATE EAST CENTER Reviewed for Code Compliance 8184 P0CATELLO,IDAHO 83201 IDENTIFICATION MARKINGS ARE APPLIED. 2.1 PLUMBING GFIXTFIXTURES RESTRIM: M PO B.EQUIPMENT: A.ALLPLUMBING FIXTURES SHALL BE PROVIDED COMPLETE WITH ALL REQUIREDTRIM FOR A COMPLETE AND OPERATIONAL SYSTEM. PLANS MUST BE ON JOB SITE ,rTMaT 05,2024�o PHONE: (208)233-0501AULPLUMBING FIXTURES SHALL BE CAULKED AND SEALED TO - 1.IDENTIFY ALL EQUIPMENT WITH A CLACK FORMICA LABEL,WITH WHITE REVEAL WHEN ENGRAVED.LETTERINGT0 BE3/16INCH STOP VALVES AND THE STOP VALVES SHALL BE QUARTER-TURN BRASS BALLTY TYPE. FlXTURES.EACH FAND TRIM MUST BEIXTURESHALL BE OLEADEFR EITALL 9L/rf°F\��`'�� EMAIL: eso@engsystems.com -0529 HIGH MINIMUM.IN GENERAL,IDENTIFY EQUIPMENT AS TO AREA SERVED IN ADDITION TO TITLE AND CODE NUMBEROFTHE FLOOR DRAINSAND FLOORSINKSSHALL BE PROVIDEDWITH TRAP PRIMERS(PPP,OR ZURN AS NEEDED FORAPPROPRIATE USE). FOR ALL INSPECTIONS 0 L, HP EQUIPMENT AS TAKEN FROM PLANS. ESA JOB NUMBER: 07177 Page 19 of 29 PLAN NOTES: 1D EXISTING UNIT VENTILATORS TO BE REMOVED.ALL ASSOCIATED EXPOSED PIPING TO BE REMOVED,CAP AND ABANDON IN WALL.PATCH WALL AS REQUIRED TO MATCH EXISTING. O2 EXISTING THERMOSTAT TO BE REMOVED.PATCH WALL AS REQUIRED TO MATCH EXISTING. O REMOVE EXISTING PLUMBING FIXTURE AND CAP EXISTING 05.06.22 WASTE,WATER AND VENT PIPING AT MAIN IN WALL,BELOW FLOOR AND ABOVE CEILING AS REQUIRED. O4 EXISTING FIXTURES IN THIS AREA TO REMAIN UNLESS NOTED OTHERWISE.PROTECT IN PLACE. O5 EXISTING HEATER TO REMAIN.PROTECT IN PLACE. J a 5 ii i 5 5 i OFFICE OFFICE CLASSROOM (E)STG OFFICE OFFICE (E)RM (F)RM i 411 OFFICE z p u \F Q 5 CORR2 L__________J_J 0 W E)STG � ILL WAITING z O — 0 _____________ o o_____ CORR1 0 CORR3 r n u J �u B=i ,i /STG Q zz_2 Ll iy� u RMREAK 3 ; N F z 0 �J o O L ____ ur; ` o z J R�� ________ iLLl_Ji CLASSROOM �r �`> o m 11 4 W LLJ W L J 2 T; ii �' (E)MEN RR Q m - 0,� 'LL STG -- ? (7RM (E)WOMEN RR ng 3 } � � STG cc ED F'- W S Q W l7 L 2 T CORR4 RECEPTION a= �o 2 T' CLASSROOM (E)VESTIBULE CLASSROOM CLASSROOM Q 4 o, 4 4 U N M O � �wg FN FLOOR PLAN - DEMOLITION Q SCALE:118"=1'-0" North J M I� Engineered DATE: 11/13/2023 CITY APPROVED PLANS F�ss\01sALi4RN0, Syst DLH ems 111�1t�F Associates Reviewed for Cade Compliance 1355 EAST CENTER -- 8184 POCATELLO,IDAHO 83201 PLANS MUST BE ON JOB SITE s Mar 05,2024 o PHONE: (208)233-0501 M P 1�O FOR ALL INSPECTIONS 9L/p OF HA EMAIL: eso@engsystems.com JOB NUMBER: 231 37 Page 20 of 29 PLAN NOTES: PLAN NOTES: O1 INSTALL NEW HEAT PUMP ON ROOF ON STAND.DROP 13 INSTALL HOT AND COLD WATER CONNECTIONS FOR FUTURE REFRIGERANT PIPING THRU ROOF IN GOOSENECK ASSEMBLY. STACKABLE WASHERIDRYER.CONNECT TO EXISTING HOT AND SEE DETAIL ON SHEET MP2-1. COLD WATER IN THIS AREA. O INSTALL NEW FAN COIL UNIT ON WALL AS HIGH AS POSSIBLE 14 DROP 314"HOT AND COLD WATER LINES IN THIS LOCATION TO ACCORDING TO MANUFACTURERS RECOMMENDATIONS. SERVE BOTH THE SINGLE COMPARTMENT AND TRIPLE COMPARTMENT SINK FROM BELOW. O ROUTE CONDENSATE LINE IN CEILING SPACE OF HALLWAY AS MUCH AS POSSIBLE.DROP DOWN IN WALL AND CONNECT TO 15 RUN 314"COPPER CONDENSATE DRAIN LINE FROM ------------------1 SINK SIDE OF P-TRAP WITH DISHWASHER CONNECTION. REFRIGERATION UNIT IN FREEZER I COOLER EXPOSED ON 05.06.22 CEILING OF COOLER I FREEZER THRU WALL OF COOLER I O ROUTE CONDENSATE LINE IN CEILING SPACE THRU EXTERIOR FREEZER AND DROP EXPOSED DOWN TO FLOOR SINK. GT-1 I WALL AND TERMINATE WITH DOWNTURNED 90°ELBOW. TERMINATE 314"CONDENSATE DRAIN LINE IN FLOOR SINK W S-3 I COMPLETE WITH AIRGAP.ALL PIPING LOCATED INSIDE FREEZER I CLASSROOM 1 I FS-1 I (E)STG O ROUTE CONDENSATE LINE IN CEILING SPACE AND DROP TO COOLER TO BE HEAT TRACED. OFFICE 2 OFFICE 3 I 0-1 I (E)RM FLOOR DRAIN IN STORAGE ROOM COMPLETE WITH FS-1 IJUICE BAR DOWNTURNED 90 DEGREE ELBOW AND AIR GAP. 16 CONNECT NEW HOT AND COLD WATER LINES TO NEARBY KITCHEN (E)RM EXISTING.ROUTE WATER LINES HIGH IN CORRIDOR EXPOSED AND O INSTALL NEW ERV UNIT IN MEZZANINE AREA ABOVE OFFICE IN WALL AS MUCH AS POSSIBLE TO NEW FIXTURE(S).COORDINATE FS-1 HS 1 12 SPACE AS HIGH AS POSSIBLE AND SUPPORT FROM FLOOR ON 112" CUTTING AND PATCHING OF EXISTING WALLS.FIELD VERIFY O I ISOLATION PADS. EXISTING SIZES AND CONDITIONS. ICE I O EXTEND SUPPLY AIR FROM ERV THRU WALL AND DROP DOWN 17 CONNECT WATER,WASTE AND VENT PIPING TO NEW BREAK - } CORR2 I (E)STG THRU ROOF TO CORRIDOR CEILING.SEAL PENETRATIONS ROOM SINK.RISE VENT LINE IN WALL AND CONNECT TO NEAREST 314" WEATHER TIGHT.RUN DUCTWORK AS HIGH AS POSSIBLE IN EXISTING.COORDINATE WITH GENERAL CONTRACTOR FOR SAW 4„ L_______________ -J WAITINGL CORRIDOR.COORDINATE WITH LIGHTING AND OTHER DEVICES. CUTTING OF EXISTING CONCRETE SLAB FLOOR. CORR3 WH-2. CORR1 O EXTEND EXHAUST AIR FROM ERV THRU WALL AND DROP DOWN 18 CONNECT NEW WASTE,WATER AND/OR VENT TO NEARBY 19 14' STG THRU ROOF TO CORRIDOR CEILING.SEAL PENETRATIONS EXISTING PIPING OF SAME SIZE OR LARGER.COORDINATE WITH 1/2" 16 _T 112' 16_ WEATHER TIGHT.RUN DUCTWORK AS HIGH AS POSSIBLE IN GENERAL CONTRACTOR FOR ANY SAW CUTTING OF EXISTING 4RRWC-1 (E)WH-1 CORRIDOR.COORDINATE WITH LIGHTING AND OTHER DEVICES. CONCRETE SLAB FLOOR.FIELD VERIFY EXISTING CONDITIONS._ OFFICE 1 RP-1 CLASSROOM ADA RREG-3 1 ROUTE SUPPLY DUCT TO OFFICE IN MEZZANINE SPACE. 19 INSTALL WATER HEATER WITH DRAIN PAN IN MEZZANINE AREA r , 13 W&1 16 ABOVE OFFICE TO SERVE NEW KITCHEN FIXTURES.PIPE DRAIN 1®r (E)MEN RR 10 ROUTE DUCTWORK THRU CORRIDOR AS HIGH AS POSSIBLE.SEAL LINE FROM DRAIN PAN TO FLOOR DRAIN IN STORAGE ROOME) (E)RM F �L 1 (E)WOMEN RR 16 WALL PENETRATION. BELOW.CONNECT TO EXISTING COLD WATER TO INLET. STG BREAK ROOM8 11 SEE LARGE SCALE PLAN A ON THIS SHEET FOR CONTINUATION 20 SEE PLUMBING FLOOR PLAN ON THIS SHEET FOR CONTINUATION. B .OF PIPING IN THIS AREA.CORR 4 RECEPTION PROVIDE DRYER WALL BOX IN WALL COMPLETE WITH 4"0 DUCT 4" _ 4" 2� 2 SEE LARGE SCALE PLAN B ON THIS SHEET FOR CONTINUATION UP IN WALL TO WALL DRYER CAP.INSTALL 4'0 DRYER VENT Fr 1 H OF PIPING IN THIS AREA. RISING UP FROM 12'ABOVE FINISHED FLOOR LEVEL. zz 1 1 18 7 1 S-1 TAI O (E)VESTIBULE O CLASSROOM PLUMBING FLOOR PLAN LL SCALE:118"=1'-0" North p z U— m z O Q Z d N Q NOTE: � ALL REFRIGERANT LINES AND W w z W w Q DUCTWORK TO BE LOCATED ON 0 of 00 = ROOF UNLESS NOTED OTHERWISE. O S GREASE 2 (j w U W INTERCEPTOR Q W 1Q 14 J � 4 S.1 DF-1 CLASSROOM 2,V 2 FC o OFFICE2 314"OFFICE �112__ _ 112"(E) 20 15 JS1 SA 1A 1 FO o 0 0 2„ 112" 1 4" 15 112' q" 44 .7L I " KITCHEN FS-1 �� 4„ 2" LIT 18 4" LI _=- 2„ i__+ I I I 22'VFR 18'0 FC FC HP 1Y2" L_1 _ - I g " 4" 160 10 38 3C � ERR III _____ __H ____ ___ 2 2 JUICEBAR p' 10 SG-1 3T. p 2 18 — _2"V �� I 0-1 JUICE BAR HP �-1r 1 1 1 100 10 I WC-2 I 'Z' KITCHEN 1 SG-1 L-1 1 ---I- 1 rn 180 8. 314' FD-1 10 8"0 I 3 4"-1 I 112" __� 5 1 - 20 314" V OFFICE 1 CHILDREN'S RRFG 2"V _-I 112 FC 2 1B 10 3A 2 314' STG 2"VTR �IC HS-1 N PT,W D-1 2' 11 Sg OEG-1 g 20 S-1 r r F o 10 330 7 4"0 5 ' 21 EH STG J 1 o EL-1 R 5 18 H U FRR OL A BATHROOM PLUMBING FLOOR PLAN B KITCHEN PLUMBING FLOOR PLAN M 10 EG-2 10 21 1 SCALE:1/4"=1'-0" North SCALE:114"=1'-0" North 150 CHILDREN'S RR L s L s . 314" 2 FC 2P 2 2B 2A CLASSROOM Engineered DATE: 11/13/2023 �"'ONAL F4,GiI& systems MECHANICAL FLOOR PLAN CITY APPROVED PLANS 5 RF �� Associates 1355 EAST CENTER Reviewed for Code Compliance --�8184 POCATELLO,IDAHO 83201 SCALE:1/8"=V-0" North os Mar 07,2024 o PHONE: (208)233-0501 0529 M P 1�� PLANS MUST BE ON JOB SITE 9G0 L OF EMAIL:EMAIL: esasengsyst ms..com FOR ALL INSPECTIONS ESA JOB NUMBER: 23137 Page 21 of 29 NATURAL OUTDOOR AIR VENTILATION CALCULATIONS ENERGY RECOVERY VENTILATION UNIT SCHEDULE FAN COIL INDOOR UNIT SCHEDULE OPENABLEWINDOW OPENABLEDOOR REQ'D AR (Am EXHAUSTAIRSECTION CA SUPPLY SECTION BLOWERSECTION DX COOLING COIL PIPING SIZES HEATING ACTUAL AREA SYM. CHAR. MCA MOOR WEIGHT REMARKS SYM. TYPE CFM MCA MOOR BTU EAT LAT LID SUCT. CD MBH CHAR REMARKS ZONE AREA(Az) AREA(Aw) AREA(Ad) An=Az"4% C.F.M. S.P.E. H.P. C.F.M. S.P.E. H.P. ROOM AI=Aw+Atl (Note 1) (Note 1) (Note 2) (2)01,2 ATFLAOTAL RENEWAIRE-MODEL EV4501N VERTICAL INDOOR UNIT WITH FC WALL DAIKIN MODEL FTXSIBLVJU WITH WALL MOUNTED 480 0.50 0.6 480 0.60 0.6 1201601115 250# 1A MOUNTED 38PS80 0.32 20 18,000 75°F 55°F 114" 1YT 518" 18,000 20816011 CONTROLLER 8INTERNAL CONDENSATE PUMP. SF SF SF SF SF 1 9.0 MCA TOTAL BACKDRAFT DAMPERS AND MERV 13 FILTERS FC WALL 380-W 0.32 20 18,000 75°F 55°F 114' 1/7, 518" 18,000 20M011 DAIKIN MODEL FTXSIBNAL CONDENSATE WALL NSATE PUNTED MP. Classroom 2 875 24 21 35 45 iB MOUNTED CONTROLLER 8INTERNAL CONDENSATE PUMP. Office 144 6.3 - 5.8 6.3 HEAT PUMP OUTDOOR UNIT SCHEDULE ?A MOUNTED 380-W 0.32 20 WALL 18,000 75°F 55°F 114' 1n" 518" 18,000 20&16011 CONTROLLER 8INTERNAL CONDENSATE PUMPDAIKIN MODEL FTXS18LVJU WITH WALL ED 05.06.22 Office 3 144 7.3 5.8 7.3 Note 1:Natural ventiliati0n of an occupied space shall be through windows,doom,louver or other openings to the outdoors per IMC Section 402.1 COOLING HEATING REFRIGERANT PIPING SIZES FC WALL DAIKIN MODEL FTXS18LVJU WITH WALL MOUNTED SYM. TYPE WEIGHT BTU BTU CHAR MCA MOP CFM LIQUID LOW PRESS. REMARKS 28 MOUNTED 380-W 0.32 20 18,000 75°F 55°F 114' 117, 518, 18,000 20816011 CONTROLLER&INTERNAL CONDENSATE PUMP. Note 2:The minimum operable area to the outdoors Shall be 4%of the floor area being ventilated per IM C Section 402.2 HP DAIKIN MODEL 4MXS36NMVJU UNIT FC WALL DAIKIN MODEL FTXS09LVJU WITH WALL MOUNTED HEAT PUMP 144# 36,000 36,000 20816011 20.9 25 2811 1l4' 318" WITH LOW AMBIENT'HARD-START KIT. 3A MOUNTED 1 45.380 0.15 15 9,000 75°F 55°F 1/4' 318" 518" 12,000 20816011 CONTROLLER&INTERNAL CONDENSATE PUMP. MECHANICAL OUTDOOR AIR VENTILATION CALCULATIONS 2P HEAT PUMP 1- 31 36,000 20816011 20.9 25 2611 318" DAIKIN MODEL 4MX1361MVJU UNIT FC WALL 45380 0.15 5 9,000 75°F 55°F 38" 58" 2,000 2086011 DAIKIN MODEL FTXS09LVJU WITH WALL MOUNTED WITH LOW AMBIENT'HARD-START KIT. 3B MOUNTED CONTROLLER&INTERNAL CONDENSATE PUMP. ZONE PEOPLE AREA BREATHING ZONE ZONE AIRRIQ'D ZONE ACTUAL HEAT PUMP 21- 47,000 48500 20816011 M-13 35 M. 1/4' 3W DAIKIN MODEL 4MXS36NMVJU UNIT FC WALL 145380 0.15 15 9,000 75°F 55°F 114' 318" 518" 12,000 20fl16011 DAIKIN MODEL FTXS09LVJU WITH WALL MOUNTED UNIT ZONE OCCUPANCY POPULATION OUTDOOR OUTDOOR (Vbz) DISTRIBUDOOR AIR OUTDOOR WITH LOW AMBIENT'HARD-START KIT. 3C MOUNTED CONTROLLER 8INTERNAL CONDENSATE PUMP. SERVING ROOM AREA Az DENSITY ( ) (z) RATE(Rp) RATE(Ra) VbRz'Vb a*Az EFF(E Voz--VbzlEz AIR 3D MOUNTED COINTROLLERLB NTEIRNAL ONDENSATE PUMPED 380680 0.32 20 18,000 75°F 55°F 114" 1YT 518" 18,000 20816011 SF #I1,OOOSF People CFM/Per CFM/SF CFM Note I cFM CFM ELECTRIC HEATER SCHEDULE Classroom 1 767 35 27 1 10 0.12 1 360 1 360 360 ERV Kitchen 360 20 7 7,5 0.12 97 1 97 100 SYM. TYPE Ell KW CHAR CONTROL REMARKS GRILLE AND REGISTER SCHEDULE Offcei 117 5 2 5 0.06 17 1 17 EH RECESSED WALL MTD 3,413 1.0 12016W1 INTEGRAL QMARK MODEL CWH1101DSAF WITH Note 1:Per IMC Table 403.3,1,1.1.2,the zone air distribution effectiveness is 1.0,"Ceiling or floor supply of awl air" Total ERV 475 480 1 RECESSED MOUNT FRAME SYM. SIZE THROW CFM MIN NC ING FINISH BDAUNCTH REMARKS *INSTALL ALL UNITS ON WALL 12"A.F.F.TO BOTTOM OF FRAME FNI 1 SO ®11, 20.100 20 BY ARCH VAR, PRICE MODEL SMD IN BEVELED FRAME SG1 10z10 A 180 20 BY ARCH 10z10 PRICE MODEL 520D DOUBLE DEFLECTION BLADE WITH OBD. TRANSITION FROM ROUND. TEMPERED WATER BALANCE REPORT TO VALVE FOR COLD WATER LINE o TEMPERED FI ADJUSTINER �--6 AQUASTAT i 1202 NA 330 20 BY ARCH 10z10 PRICE MODEL 535 WITH OBD.TRANSITION FROM ROUND. TO FINISH FLOOR LEVEL FLOOR DRAIN BODY BE PROVIDED BEFORE THERMOMETER M a SHOT WATER EG2 9z9 NA 150 20 BY ARCH 8"0 PRICE MODEL 535 WITH OBD.TRANSITION FROM ROUND. FINAL INSPECTION 314' RECIRC TILE AND GROUT HOT WATER LINE EG8 I 10z10 NA 70 20 BY ARCH 60 PRICE MODEL 535.TRANSITION FROM EF-1 INLET. 1 DIELECTRIC UNION(TYP) RECIRC.PUMP BUILDING E� AMERICAN WARMING LE-31 WITH DRAINABLE BLADES AND INSECT 1 - EL-0 18z18 NA 480 20 BY ARCH 10z10 SCREEN 12"0 EXHAUST HEAT TRAP FITTING BALL VALVE TO OUTSIDEiMMECH. -1-12"00A FROM OUTSIDE (TYPICAL) OL-1 1808 NA 480 20 BY ARCH 12'0 SCREENAN WARMING LE-31 WITH DRAINABLE BLADES AND INSECT 12'0 SUPPLY -h 12'0 RA AMTROL ST-5 JEXPANSION TANKCONCRETE FLOOR PIPE FULL SIZE ROOM FLOOR TO FLOOR DRAIN T&P RELIEF VALVE SIZED EXHAUST FAN SCHEDULE W TO MATCH WATER Q HEATER SYM. TYPE MIN C.F.M. S.P.E. WATTS CHAR. R.P.M. CONTROL REMARKS ERV FLOW DIAGRAM EXISTING WATER HEATER ANCHOR 06 2"WASTE LINE TO ELECTRIC EF WITH TWIN CITY FAN MODEL 0608E DCRD WITH ROOF 70 0.25 6.1 12016011 935 U)W SYSTEM 2"DEEP SEAL P-TRAP NO SCALE WASTE AND VENT WATER HEATER 1 LIGHTS BACKDRAFT DAMPER WITH 12"CURB.� .Q DRAIN VALVE WI THREADED HOSE CONNECTION LJ_ co W FLOOR DRAIN IN CONCRETE FLOOR WATER HEATER PIPING DETAIL FIXTURE SCHEDULE o o6 _ LL U NO SCALE NO SCALE '11OT OLD VA Q z DF-1 BI-LEVEL DRINKING FOUNTAIN-ELKAY MODEL EZ-STLBWSLK WITH EZH20 BOTTLE FILLER FLEX1-GUARD BUBBLERS,112"STOP 22 m CA -- 112" 1-112" 1-112" N F EXTEND CONDESATE INDIRECT WASTE AND 1-1/2"P-TRAP.PROVIDE ALL INTERCONNECTING PIPING AND DRAIN. o DRAIN LINE OUT OF LINE DOWN IN 2' D - RN "0 CK - ONZE S IN 2 P .P VID P 0 D z m D WALL BELOW CABINET WALL OR CHASE FD-1 _ -- 2" 2" W = __J TRAP GUARD SEAL. LU W w d TYPICAL ELBOW DOWN 90° POWER EXHAUSTER DOWN-BLAST TYPE 4'FLOOR SINK WITH 314 GRATE Z-1900J WITH 314 GRATE,WHITE ENAMEL FINISH,DOME STRAINER AND SEAL COUNTERTOP SINK CONDENSATE DRAIN ._ ._ S FS-1 LINE DOWN IN WALL TO RECEPTOR. EXHAUST FAN P-TAP. 4" 2 C U (MAINTAIN CODE SECURE 8 CAULK GREASE INTERCEPTOR K.E.C.#16-TO BE FURNISHED AND INSTALLED BY K.E.C.PLUMBING CONTACTOR TO ROUGH-IN - -- 3' - - Cn w W REQUIREDAIRGAP) _ _ TO CURB GT-1 AND CONNECT 3"WASTE TO FLOOR SINK WITH AIRGAP. TO Q BIRD SCREEN RORUCTURE OF ST CONNECTION 2"VENT FS-1 DISHWASHER ESCUTCHEON HANDWASH SINK K.E.0#8-TO BE FURNISHED AND INSTALLED BY K.E.C.PLUMBING CONTACTOR TO ROUGH-IN AND 11T 112" 1-11T 1-112' H&1 ATMOSPHERE RE PLATE BACKDAFT CONNECT 112'CW&HW LINE COMPLETE WITH BALL TYPE SHUT-OFF VALVES&S.S.BRAIDED SUPPLIES,1-11T TAILPIECE& SANITARY TEE DAMPER CEILING Pi PROVIDE AND INSTALL WATTS 112'THERMOSTATIC MIXING VALVE TO BE MOUNTED UNDER SINK ON WALL. EG3 ICE ICE MAKER K.E.C#9-TO BE FURNISHED AND INSTALLED BY K.E.C.PLUMBING CONTACTOR TO ROUGH-IN AND CONNECT 11T - 112' - - CW CONNECTION AND SHUT OFF VALVE.MOUNTED RECESSED IN WALL NEAR FLOOR WITH BACKFLOW PREVENTION DEVICE. TAP WALL FINISHED FLOOR �'- -J 0.1 ELECTRIC COMBI-OVEN K.E.0#14-TO BE FURNISHED AND INSTALLED BY K.E.C.PLUMBING CONTACTOR TO ROUGH-IN AND - 314" 2' - FLOOR _ CONNECT 112"CW COMPLETE WITH BALL TYPE SHUT-OFF VALVE&S.S.BRAIDED SUPPLY,2"WASTE TO FLOOR SINK WITH NOTE: = SERVICE SINK N JS-1 MOP SINK K.E.C.#2-TO BE FURNISHED AND INSTALLED BY K.E.C.PLUMBING CONTACTOR TO ROUGH-IN AND CONNECT 112" 1Y1" 112" 2' 2' WALL MOUNTED TE D LAVATORY TO FLOOR DRAIN O CW&HW LINE,2"DEEP SEAL P-TAP AND 2"VENT LINE. WALL MOUNTED LAVATORY SIMILAR OR FLOOR SINK CA -49- CL 1 112'STOPS,1-1/2"P-TAP AND MOEN L4601 FAUCET.PROVIDE INSULATING JACKET ON WASTE AND HOT WATER LINES. COND. DRAIN CONNECTION DETAIL INDIRECT DRAIN DETAIL ROOF MOUNTED EXHAUST FAN DETAIL S1 SINGLE COMP.SINK WITH FAUCET-ELKAY MODEL LR-2219 WITH 18 GA TYPE 304 STAINLESS STEEL CONSTRUCTION,3-HOLE 1/2" 1/2" 1-112' 1-112' o NO SCALE NO SCALE NO SCALE O FAUCET DRILLINGS,LK-4100 LEVER HANDLE FAUCET,LK-99 STRAINERS,1-11T P-TRAP AND 112"BALL TYPE STOPVALVES. DOUBLE COMPARTMENT SINK-FLAY MODEL LR4319 STAINLESS STEEL SINK WITH MOEN 7200 SINGLE LEVER HANDLE,(2)LK-99 112" 112" 1-112" 1-112" S-2 HEAVY DUTY STAINER,1.112"P-TAP,AND 112"STOPS, V PROVIDE SUPPORT AT TRIPLE COMP.KITCHEN SINK K.E.C#4-TO BE FURNISHED AND INSTALLED BY K.E.C.PLUMBING CONTACTOR TO ROUGH-IN 112" 112" 2' -- ROOF ROOF PENETRATION - _ GALVANIZED METAL VENT �3 AND CONNECT(2)112"CW&HW LINES TO(2)FAUCETS COMPLETE WITH BALL TYPE SHUT-OFF VALVES&S.S.BRAIDED TO THRU ROOF WITH SUPPLIES,2"WASTE HEADER TO FLOOR MOUNTED GREASE TAP. QT.1 w GOOSENECK. 2' w SEAL ROOF KITCHEN SINK K.E.0#3-TO BE FURNISHED AND INSTALLED BY K.E.C.PLUMBING CONTACTOR TO ROUGH-IN AND CONNECT 12' 112" -- PENETATION i i// 112'CW&HW LINE TO PRE-RISE FAUCET COMPLETE WITH BALL TYPE SHUT-OFF VALVES&S.S.BRAIDED SUPPLIES,2"WASTE TO WEATHER TIGHT. I. TO FLOOR MOUNTED GREASETAP. GT-1 V 1 t 1 MOUNT OUTDOOR UNIT ON . 4 fROOF WITH 44 REDWOOD WB-1 WASHTER BOX-POLY WASHER BOX WITH 112"HW AND CW STOP VALVES AND 2"STANDPIPE WITH P-TAP.CONNECT WATER 112" 112" 2" 7 p/ W`o J j AILS.WRAP 44 AILS WITH NON HARDENING AND WASTE TO EXISTING. w TYP.ROOF JOIST J ROOFING MATERIAL. FLASH ONTO ROOF CAULK WC-1 ADA CHILD HEIGHT TANK TYPE WATER CLOSET-AMERICAN STANDARD BABY DEVERO 1.28 GEE FLOWISE 101NCH HIGH -- 112" 4" 7 AND SEAL WATERTIGHT b STORM TOILET,BABY DEVERO 5001G.055 WHITE OPEN FRONT SEAT,BOLT CAPS AND 112'STOP VALVE.RIGHT OR LEFT HAND FLUSH COLLAR LEVER SO LEVER IS ON OPEN SIDE OF ACCESSIBLE STALLS. �� z BOLT TONEOPRENE REDWOOD AILS WITH 1" p I I Wpp CHILD HEIGHT TANK TYPE WATER CLOSET-AMERICAN STANDARD BABY DEVERO 1.28 GEE FLOWISE 101NCH HIGH TOILET, - 112" 4" 2" M FC THICK NEOPRENE PAD =___ _____ FLASHING BABY DEVERO 5001G.055 WHITE OPEN FRONT SEAT,BOLT CAPS AND 112-STOP VALVE. i 1 4"MIN. O ADA TANK TYPE WATER CLOSET-KOHLER K-3999"HIGHLINE"WI ELONGATED BOWL,K4670-C WHITE OPEN FRONT SEAT,BOLT - 112 4" 7 WC� CAPS AND 112"STOP VALVE.LEFT OR RIGHT FLUSH VALVE AS PER PLANS. WH-2 50 GALLON ELECTRIC WATER HEATER-A.O.SMITH MODEL SIGNATURE 900 WITH 50 GALLON CAPACITY,(2)4.5 KW NON- 314" 314" - - 314' SIMULTANEOUS ELEMENTS(20816011),314"SUPPLIES AND T&P RELIEF VALVE,THERMAL EXPANSION TANK,AND HEAT TRAP �REFRIGEPIPING TO NIPPLES. NOTE: NIT 1 PRE-CHARGE LINE SETS ARE AVAILABLE IN J LENGTHS OF 16,20,32 AND 49 FEET.LENGTHS RISE REFRIGERANT PIPING UP ARE TO BE KEPT AS SHORT AS POSSIBLE. THRU ROOF.REFER TO SPLIT COILING OF LINES THAT ARE TOO LONG WILL CONCEAL CONTROL AIC UNIT SCHEDULE FOR LINE NOT BE ACCEPTABLE AND WILL BE REPLACED WIRING IN WALL. SIZES. AT CONTRACTOR'S EXPENSE. �ii REFRIGERANT PIPING TO ® Engineered DX COOLING COIL DATE: 11/13/2023 RUN 3/4"CONDENSATE DRAIN LINE TO �"'ONAL F'vC Systems DLH NEAREST FLOOR DRAIN OR MOP SINK. WALL MOUNT DIGITAL CONTROLLER b 1S RF �<^ Associates CITY APPROVED PLANS 1355 EAST CENTER FAN COIL&REFRIGERANT PIPING DETAIL PIPING THRU ROOF DETAIL Reviewedfor Code Compliance -�8184 POCATELLO,IDAHO 83201 s Mar 07,2024 o PHONE: (208)233-0501 M P2-1 NO SCALE NO SCALE PLANS MUST BE ON JOB SITE EM (208)233- 529 L OF H AIL: esag FOR ALL INSPECTIONS ESA JOB NUMBER: 23137 Page 22 of 29 ELECTRICAL SYMBOL SCHEDULE PROJECT GENERAL NOTES: ELECTRICAL EQUIP. CLEARANCE NOTE AU_SYMBOLS y NOT BE USED SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION A. E.C.SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL MECHANICAL ELECTRICAL PANELBOARD,(SEE POWER RISER AND PANEL SCHEDULES F1 LIGHT FIXTURE TYPE DESIGNATION (D KEYED NOTE REFERENCE EQUIPMENT AND ELECTRICAL CONNECTIONS. •u,• FOR ADDITIONAL INFORMATION) B. E.C.SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL \ PARKING AREA POLE LIGHT,SINGLE OR DOUBLE HEAD AS INDICATED ON 1/ES101 DETAIL#/SHEET REFERENCE PANELS OR CABINETS.SEE ELECTRICAL EQUIPMENT CLEARANCE DETAIL. i --r"`' DRAWINGS.REFER TO LIGHT POLE DETAIL FOR POLE INFORMATION. DISCONNECT NEMA 1,3R=SIZE/PO 4X=N PE AS INDICATED C. INSTALL ALL LIGHT FIXTURES I MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE. BRANCH CIRCUIT HOME-RUN TO PANEL INDICATED r � 1�1 TYPES:I=NEMA I,3R=NEMA 3R,4X=NEMA 4X ADJUST AS NECESSARY.PROVIDE CHAIN SUSPENSION KITS AS REQUIRED. A-1,3,5 A-1,3,5 PArvek ArvoclRculT Osslcrvnnorvs ����� I / ELECTRICAL 4 EXTERIOR WALL MOUNTED FIXTURE D. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN(S)FOR EXACT FIXTURE LOCATIONS,CEILING 3l4"C:6#12,1#12G 3l4"C:6#12,1#12G � EQUIPMENT Q JUNCTION BOX ,1 1, TYPES,ETC. 2X4 FLUORESCENT OR LED FIXTURE �QTY&SIZE OF NEUTRAL A D OUNDPHASE CONDUCTOR E. E.C.SHALL PROVIDE ALL CONCRETE PADS AS REQUIRED FOR ALL ELECTRICAL EQUIPMENT. 'YO EQUIPMENT R CONNECTION;COORDINATE CONNECTION WITH EQUIPMENT ......CONDZE OFUIT NEUTRAL AND PHASE CONDUCTORS) F. CONFIRM EXACT LOCATIONS OF ALL TELEPHONEIDATA OUTLETS WITH OWNER PRIOR TO ROUGH-IN. ® PRIOR TO ROUGH-IN SIZE OF CONDUIT G. LOCATE SWITCHES,OUTLETS,ETC.,SHOWN AT ROOM ENTRY DOORWAYS,AS CLOSE TO DOOR FRAME AS it FM M� MOTOR CONNECTION ® 2X2 FLUORESCENT OR LED FIXTURE '25,000A CALCULATED AVAILABLE FAULT CURRENT AT EQUIPMENT(SEE POWER RISER) POSSIBLE,SO AS NOT RO INTERFERE WITH ROOM CABINETS,ETC. o H. SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING. EXHAUST FAN CONNECTION Ic, SURFACE MOUNTED FLUORESCENT OR LED FIXTURE BRANCH CIRCUITIFEEDER CONCEALED IN CEILING OR WALL I. ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR WORK AND PAY ASSOCIATED ____ ( STRIP FLUORESCENT OR LED FIXTURE - BRANCH CIRCUIT/FEEDER CONCEALED UNDERGROUND OR FLOOR ,try SPECIAL RECEPTACLE(COORDINATE NEMA TYPE WITH EQUIP.) � J FEES. NOTE#2. MAINTAIN 24"MIN.CLEARANCE FROM ALL COMMUNICATIONS CABLING AND ELECTRONIC BALLASTS. 'Nr (REFER TO PANEL SCHEDULES FOR AMPS) NEW EQUIPMENT,DEVICES,ETC. K. UNLESS SPECIFICALLY INDICATED OTHERWISE,E.C.SHALL COORDINATE WITH ANY SPECIAL SYSTEMS i WALL MOUNTED FLUORESCENT OR LED FIXTURE SUPPLIERISHOP DRAWINGS;DENTAL,MEDICAL,KITCHEN,SPECIALIZED EQUIPMENT,ETC.FOR THE EXACT 9 DUPLEX RECEPTACLE,UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT ® ROUND RECESSED FIXTURE ----- EXISTING EQUIPMENT,DEVICES,ETC. ROUGH-IN REQUIREMENTS FOR THEIR EQUIPMENT.ALSO UNLESS INDICATED OTHERWISE,THE E.C.TO BE RESPONSIBLE FOR FINAL ELECTRICAL CONNECTIONS TO ALL SPECIAL EQUIPMENT. GFCI-TYPE DUPLEX RECEPTACLE,UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT DEMOLITION EQUIPMENT,DEVICES,ETC. L. ALL CONDUIT/RACEWAY/CABLES TO BE CONCEALED IN WALLS OR ABOVE CEILINGS.IF ANY SURFACE _ _ _0.X DATA AND/OR TELEPHONE OUTLET;=#OF DATA CABLES,X=CONDUIT SIZE(SEE NOTES WORK IS NECESSARY,IT SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. HAVECONSTANTEPTACLE,HALF OF RECEPT.SHALL BE SWITCHED OTHER HALF SHALL EXIT SIGN,WALL OR CEILING MOUNTING AS REQUIRED(SINGLE OR DOUBLE FACE) 0 1,2,3 BELOW) M. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE GENERAL NOTES: POWER. ® I9I DIRECTIONAL CHEVRONS AS INDICATED;CONNECT TO UNSWITCHED LEG OF LIGHTING EXISTING CONDITIONS,AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED.MAKE NECESSARY A. ALL WORKING SPACE CLEARANCES ARE FROM THE FACE OF THE EQUIPMENT. CIRCUIT THAT IS IN THE SAME AREA AS THE EXIT SIGNS. D-X CEILING MOUNTED DATA OUTLET;=#OF DATA CABLES,X=CONDUIT SIZE DOUBLE-DUPLEX RECEPTACLE,UL TAMPER-RESISTANT WHERE MOUNTED BELOW 5FT �I ® (SEE NOTES 1,2,3 BELOW) PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. NOTES: ,a� N. DATA CABLING SYSTEM PRE-INSTALLATION CONFERENCE: 1. THE MINIMUM HEADROOM OF WORKING SPACE SHALL BE 61/2FT. F GFCI-TYPE DOUBLE-DUPLEX RECEPTACLE,ULTAMPER-RESISTANT WHERE MOUNTED WALL OR CEILING MOUNTED EMERGENCY LIGHTING UNIT W/BATTERY PACK (� TELEVSION OUTLET;CABLE TO NEAREST TTB 1. E.C.SHALL SCHEDULE A MEETING A MINIMUM OF FIVE CALENDAR DAYS PRIOR TO BEGINNING DATA 2. THE WIDTH OF THE WORKING SPACE SHALL BE THE WIDTH OF THE EQUIPMENT OR 30",WHICHEVER IS < BELOW 5FT. pt ry ry CONNECT TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT IS IN THE SAME AREA AS CABLING INSTALLATION.ATTENDEES SHOULD INCLUDE OWNER'S REP.,ENGINEER,GC,EC AND GREATER.THE PANEL DOOR SHALL OPEN AT LEAST 90 DEGREES. RECEPTACLE AND EQUIPMENT SUBSCRIPTS THE EMERGENCY LIGHT. FB# ELECTRICAL FLOORBOX;REFER TO"ELECTRICAL FLOORBOX SCHEDULE"FOR CABLING SUB.REFER TO SECTION 26 6210(1.4)(E)FOR ADDITIONAL INFORMATION. 3. ALL CIRCUIT BREAKERS,WHEN IN THIER HIGHEST POSITION,SHALL NOT BE MORE THAN 6FT 7IN.ABOVE WE MICRO WAVEIRANGE HOOD(LOCATE ABOVE RANGE) AC ABOVE COUNTER SHADED FIXTURE INDICATES AN EMERGENCY FIXTURE.PROVIDE WITH EMERG.BATTERY DX INFORMATION. =#OF DATA CABLES,X=CONDUIT SIZE(SEE NOTES 1,2,3 BELOW) THE FINISHED FLOOR. USB DUPLEX RECPT.WITH(2)USE CHARGING PORTS wP WEATHERPROOF(UL LISTED WEATHER- ® PACK OR CONNECT TO EMERGENCY POWER SYSTEM(WHERE APPLICABLE).CONNECT 4. 3FT CLEARANCE IF 0-150V TO GROUND,3.5FT CLEARANCE IF 151-600V TO GROUND.4FT IF EXPOSED LIVE o DW DISHWASHER,INSTALL PER NEC422.16(B)(2) RESISTANT) BATTERY PACK TO UNSWITCHED LEG OF LIGHTING CIRCUIT THAT SERVES THE SAME NAND/ORAV BOX;WITH POWER,DATAANDIORAV CONNECTIVITY PARTS ON BOTH SIDES OF THE WORKING SPACE. D/DW DISPOSALIDISHWASHER,INSTALL PER NEC 422.16(B((2) 42" MOUNTING HEIGHT ARE OR AEG AREA AS THE EMERGENCY FIXTURE.PROVIDE WITH TEST LIGHT AND SWITCH. TV RECEPT.DEDICATEDTON; REF REFRIGERATOR ###=BOX ID:REFER TO"ELECTRICAL AVlN BOX SCHEDULE"FOR INFORMATION. FIELD VERIFYFATER EIGHTW/N PRIOR TO ROUGH-IN. M MICROWAVE D-X _#OF DATA CABLES,X=CONDUIT SIZE(SEE NOTE#2 BELOW) Ewc PROVIDE GFCI PR TEC D CLOTHES DRYER(TONPERNEC422.5(A) R ELECTRCRANGE/NEMA1450R CEILING MOUNTED OCCUPANCY SENSOR,REFER TO OCCUPANCY SENSORISW FGH INSTALL CONDUIT(SIZE AS INDICATED)FROM BOX TO NEAREST ACCESSIBLE CEILING TYPICAL DEVICE MOUNTING HEIGHTS: w WELDER RECEPTACLE ® SCHEDULE FOR SENSOR TYPE AND ADDITIONAL INFORMATION. SPACE W/DATA CABLINGRERMINATIONS AS INDICATED ON DRAWINGS. 208/240V-NEMA 6-5OR O OR O HVAC THERMOSTAT OR SENSOR;COORDINATE EXACT LOCATION,SIZE AND NUMBER OF ®# SWITCH MOUNTED OCCUPANCY SENSOR,LOW VOLTAGE SWITCHPOD OR DIMMER SPECIAL SYSTEMS NOTES: GENERAL DETAIL NOTES: 0 FIRE ALARM NOTIFICATION CONDUCTORS WITH M.C. SWITCH,REFER TO OCCUPANCY SENSOR/SWITCH SCHEDULE FOR TYPE AND 1. UTILIZE 411/16"DEEP BOX WITH REQUIRED MUDRING AND CONDUIT TO ACCESSIBLE AT TIC SPACE OR A. ALL MOUNTING HEIGHTS TYPICAL UNLESS DEVICE ADDRIONALINFORMATION. DATA RACK,TERMINATE WITH INSULATED THROAT BUSHING,PROVIDE QTY OF CABLES INDICATED FROM NOTED OTHERWISE. FIRE ADDRESSABLE FIRE ALARM DETECTOR WITH BASE SINGLE-POLE SWITCH(SEE SUB-SCRIPTS BELOW FOR ADDITIONAL INFORMATION) OUTLET TO NEAREST TELE/DATA ROOM.SEE DWGS FOR ADDITIONAL INFORMATION.UTILIZE J-HOOKS B. COORDINATE OUTLET HEIGHTS WITH OD DETECTOR SUBSCRIPTS $ 3FT ON CENTER FOR SUPPORT OF CABLING WHERE CABLE TRAY IS NOT INSTALLED/SPECIFIED. ## P PHOTOELECTRIC SMOKE DETECTOR D DUCT SMOKE DETECTOR SWITCH SUBSCRIPTS 2. CONDUIT SIZE(W FROM ABOVE);2=1/2'13=3/4',4=1",5=1-1/4'l 6=1-12' ARCHITECTS MILLWORK DWGS.TO INSURE VERIFY WITH M C.PRIOR THERMOSTAT OR TO U) ID IN-DUCT SMOKE DETECTOR H HEAT DETECTOR 3. BLANK(NO LABEL)=4-11/16"DEEP BOX WITH REQUIRED MUDRING AND("CONDUIT TO ACCESSIBLE THAT OUTLETS WILL NOT FALL BEHIND J M MULTI-STATION SMOKE DETECTOR(120V WBATTERY BACKUP) 3 3-WAY SWITCH LV LOW-VOLTAGE SWITCH(PER DWGS) ATTIC SPACE,TERMINATE WITH INSULATED THROAT BUSHING,PROVIDE PULL STRING. CABINETS,BACKSPLASHES,OR INTERFERE ROUGH-IN. 4 4-WAY SWITCH T THERMAL-OVERLOAD SWITCH (UNLESS OTHERWISE NOTED) Q WITH WAINSCOTING,ETC. �pyl WALL MOUNTED FIRE ALARM STROBE OR SPEAKERISTROBE D DIMMER SWITCH(COMPATIBLE W/LOAD&LTG TYPES) M SWITCH SUPPLIED WITH EQUIPMENT, LIGHT SW. MANUAL PULL STATION ® IZSI PROVIDE CANDELA RATING AS REQUIRED BY NFPA 72 FT FAN TIMER,10/20/30/60 MIN.ELECTRONIC INSTALLED BY E.C. C. ALL SWITCHES AND THERMOSTATS TO BE LL.I HANDLE SHALL BE PI MODEL EI210 SERIES) WP WEATHERPROOF MOUNTED CLOSE TO DOOR JAMS AS CI P PI LOT LIGHTED SWITCH 2P DOUBLE POLE,SINGLE THROW SWITCH BETWEEN 42"848"AFF CABINET II��,p,�I CEILING MOUNTED FIRE ALARM STROBE OR SPEAKER/STROBE POSSIBLE.COORDINATE ALL DEVICES WITH ® PROVIDE CANDELA RATING AS REQUIRED BY NFPA 72 ARCHITECTURAL PLANS AND DETAILS. FIRE GENERAL POWER&PROJECT NOTES: GENERAL LIGHTING NOTES: GENERAL SPECIAL SYSTEM NOTES: D. COORDINATE LIGHT SWITCH&OUTLET 'Q.' TYPICAL FOR ALL DEVICES O J HEIGHTS WITH ARCHITECTURAL LL A. ALL DEVICES SHOWN AT OR NEAR MILLWORK/CASEWORK SHALL BE COORDINATED WITH THE A. SYMBOLS SHOWN ABOVE MAY NOT REPRESENT ALL LIGHT FIXTURES USED ON PROJECT,REFER TO A. COMMUNICATIONS CABLES SHALL HAVE BENDS NO GREATER THAN 90 DEG. WAINSCOTING AND OR TILE WORK$O AS RECEPTACLE MOUNTED ABOVE COUNTER o O ARCHITECTURAL ELEVATION DRAWINGS AND MILLWORK INSTALLER TO INSURE PROPER MOUNTING LIGHT FIXTURE SCHEDULE FOR ACTUAL FIXTURE INFORMATION INCLUDING FIXTURE TYPE,LAMPING, B. CONDUITS FOR COMMUNICATIONS CABLING SHALL HAVE A MAXIMUM BEND RADIUS NOT MORE THAN IOX NOT TO FALL MIDWAY IN THESE FINISHES. g-g @MILLWORK (ie C.O.'S,DATA,PHONE eta) Z 'a CecO HEIGHTS.ADJUST DEVICES SUCH THAT THEY WILL NOT FALL BEHIND MILLWORK,CABINETS OR BE MOUNTING AND ETC. THE DIAMETER OF THE CONDUIT. _O u G DIRECTLY ABOVE SINKS OR MIDWAY BETWEEN TILEWORKIWALL OR WAINSCOATING,ETC. B. JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY.THE E.C.IS RESPONSIBLE C. ALL COMMUNICATIONS CONDUITS SHALL BE TERMINATED WITH AN INSULATED NON-METALLIC BUSHING `4'-0" B. CONTRACTOR SHALL INSTALL PROVIDE GFCI PROTECTION OF RECEPTACLE(S)SHOWN IN BATHROOMS, FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT AT BOTH ENDS. 6" ® ~ z KITCHENS OUTDOORS OR WITHIN 6FT OF ANY SINK BASIN TUB OR FLOOR SINK AND ALL OTHER AREAS FIXTURES THAT ARE NOT LISTED FOR'THROUGH-BRANCH CIRCUIT WIRING'. D. COMMUNICATIONS CONDUITS SHALL HAVE NO MORE THAN 2 90'S WITHOUT A PULLBOX.PULL BOXES GENERAL COORDINATION NOTE: Q O '3'-6" BACKSPLASH 22 DEFINED BY THE NEC. C. IN GENERAL ALL SWITCH-LEG CONDUCTORS MAY NOT BE SHOWN ON DRAWINGS;E.C.SHALL PROVIDE SHALL BE LOCATED IN ACCESSIBLE LOCATIONS AND SHALL BE SIZED AT LEASED 12X THE LARGEST TELEIDATA TV N F J E.C.SHALL COORDINATE ALL DEVICE (OR AS NOTED) C. E.C.SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATIONS OF ALL MECHANICAL AND INSTALL CONDUCTORS AS REQUIRED TO ACHIEVE CONTROLSCHEMES INDICATED AND CONDUIT DIAMETER IN LENGTH AND MIN,4"DEEP AND 8"WIDE. RECEPT. OUTLET OUTLET z � Q EQUIPMENT AND ELECTRICAL CONNECTIONS. DESCRIBED ON DRAWINGS.INCLUDING ALL O-I OV DIMMING CONTROLS BETWEEN SWITCH AND E. IT SHALL BE THE RESPONSIBILITY OF THE E.C.TO INSURE THAT THE PATHWAY FOR THE DATA CABLING MOUNTING HGTS.AND EXACT LOCATION rn J � U D. E.C.SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL FIXTURES. DOES NOT CREATE CABLE LENGTHS TO EXCEEDS THE LENGTH OF 295FT FROM OUTLET TO PATCHLU WITH ARCHITECTURAL INTERIOR z m _ PANELS OR CABINETS.SEE ELECTRICAL EQUIPMENT CLEARANCE DETAIL. D. ALL BATTERY EXIT SIGNS AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF PANEL,THIS INCLUDES SERVICE LOOPS AND PATCH CORDS. ELEVATIONS REPORT CONFLICTS TO U5 o LU LLJ w E. E.C.SHALL COORDINATE WITH ALL SPECIAL SYSTEMS SUPPLIER/SHOP DRAWINGS;DENTAL,MEDICAL, THE LIGHTING CIRCUIT IN THE AREA. F. CONFIRM EXACT LOCATIONS OF ALL TELEPHONE/DATA OUTLETS WITH OWNER PRIOR TO ROUGH-IN. ARCHITECT TO ROUGH-IN" O 1 CABINET 0 U KITCHEN,POOL,ETC.FOR SPECIFIC ELEC.REQUIREMENTS. E. INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE. G. MAINTAIN 24"MIN.CLEARANCE FROM ALLCOMMUNICATIONSCABLING AND ELECTRONIC BALLASTS. - O F. ALL CONDUIT/RACEWAY/CABLES TO BE CONCEALED IN WALLS OR ABOVE CEILINGS.IF ANY SURFACE ADJUST AS NECESSARY.PROVIDE CHAIN SUSPENSION KITS AS REQUIRED. H. DATA CABLING SYSTEM PRE-INSTALLATION CONFERENCE: a c Lji WORK IS NECESSARY,IT SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. F. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN(S)FOR EXACT FIXTURE LOCATIONS,CEILING 1. E.C.SHALL SCHEDULE A MEETING A MINIMUM OF FIVE CALENDAR DAYS PRIOR TO BEGINNING DATA I' 8 w G w J G. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE TYPES,ETC. CABLING INSTALLATION,ATTENDEES SHOULD INCLUDE OWNER'S REP.,ENGINEER,GC,EC AND (OR AS NOTED) Q LL.I EXISTING CONDITIONS,AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED.MAKE NECESSARY G. LOCATE SWITCHES,OUTLETS,ETC.,SHOWN AT ROOM ENTRY DOORWAYS,AS CLOSE TO DOOR FRAME CABLING SUB. PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. AS POSSIBLE,SO AS NOT RO INTERFERE WITH ROOM CABINETS,ETC. FINISH FLOOR ELECTRICAL SPECIFICATIONS FIRE ALARM SYSTEM DESIGN: COMcheck Software Version 4.1.5.5 DEFERRED SUBMITTALS:Fire alarm plans shall be 1. INTENT: 7. EXECUTION: 13.WIRING DEVICES: ANAUTOMATICVOICEEVACUATIONTYPERREALARMSYSTEMSHALLBEDESIGNBUILDBYTHE sent to the Idaho State Fire Marshal's Office(ID SFM) Provide and install complete and operable electrical systems Raceway installation:Seperate underground conduits ins Devices shall be Standard type,Specification grade,color ELECTRICAL CONTRACTOR.PROVIDE AND INSTALL AS REQUIRED BY MOST CURRENT ADOPTED Interior Lighting CUnIrIIlanCe Certificate including but not not limited to;lighting,power,receptacles, common trench 4"minimum horizontally,12"minimum from as selected by owner.Decora style devices are prohibited INTERNATIONAL FIRE CODE AND LOCAL AHJ REQUIREMENTS.PROVIDEALL DOCUMENTATION,DRAWINGS, 6NX ~ data,Lire alarm ands etc. other utility lines.Minimum conduit depth shall be 18". Utilize GFCI and Tamper-proof devices in all locations as VOLTAGE DROP AND BATTERY CALCULATIONS AND ECT.TO THE CITY FOR PERMITTING AND ID$FM IF all required connections to all Mechanical and Coordinate conduit installation with pipes,steel,footings and defined by the NEC. Plumbing equipment,as indicated and required,including all ducts installed by other trades.Install conduit runs exposed to Wiring devices shall be as installed as allowed by the INSTALLATION. 208-334-4370,sfm.planreview@doi.idaho.gov conduits,wiring and controls.Coordinate with mechanical view parallel or at right angles to structural members,walls or NEC,local AHJ. Project Information contractor and drawings. building lines.Support conduit with one-hole malleable factory A. VERIFY PLACEMENT OF FIRE ALARM AND VIOCE EVAC.PANEL,NAG PANELS)AND REMOTE Energy code: 2018IECC �3 made estr s,fastendedwithscrews. 14.DEVICE PLATES: PralaclTh. ESTREET COMMUNITY CENTER-REMODEL Plans shall meet current 2018 IFC and NFPA 72,2019 ad. U PP straps, ANNUCIATORS WITH LOCAL AHJ AND OWNER. 2. COMPLIANCE WITH CODES: Devices plate type and color shall be as directed byowne () ProieaTyno: Alteration requirements and shall be approved b the ISFM and �♦ All work and material shall comply with all applicable codes, and as required b the NEC. B. PROVIDE AND INSTALL ANNUCIATION DEVICES(SMOKE/HEAT DETECTORS THROUGHOUT THE SPACE q PP Y 8. OPERATING AND ADJUSTING: eq Y safety orders,laws,ordinances and regulations of governing The owner reserves the right to operate any systems of AS REQUIRED By LATESTADOPTED VERSIONS OF NFPA 72 AND IFC.PROVIDE DETECTORS IN ALL reviewed by the TFFD FM before installation. authorities and other agencies having jurisdiction including equipment rior to final comletion and acceptance of the work. 15.LIGHTING FIXTURES: REQUIRED BEAM POCKETS,ATTIC AND MEZZANINIE SPACES. coneauruon sae: Owner/Agent oeaignencontraam: regulations of the State and Local Fire Marshall,unless P p As selected by owner and/or indicated in schedules.All if 1751 EUZABETI BLVD. PAY NE ENGINEERING 00 Such perliminary operation shall not be construed as an TWIN FALLS,ID 1823 E.CENTER ST. detailed as specified to a more restrictive standard or higher fixtures shall be installed and connected Id the Electrical POCATELLO,ID 83201 All wiring shall be inspected prior to covering. acceptance of any work. ABOVE FINISH FLOOR.THE PREFERRED HEIGHT IS 80".IF THIS CONFLICTS WITH OTHER TRADES OR (� �r requirement. Contractor. 2o6-z32-4439 Fire Ins Inspection Line 208-735-7338 ro Each piece of equipment and all of the systems shall be ROOM FURNISHINGS,LOCATE AS CLOSE TO 80"AS POSSIBLE,NOT EXCEEDING W.ALL NOTIFICATION p tLl Sri b o 3. INTERPRETATION OF DRAWINGS: adjusted to insure proper functioning and shall be left in first 16.SERVICE EQUIPMENT&PANELBOARDS: The electrical drawings are essentially diagrammatic in that class operating condition. Service Equipment:Shall be rated as such and shall comply APPLIANCES IN A COMMON ROOM OR LINE OF SIGHT SHALL BE LOCATED AT A COMMON HEIGHT. With local utility co.requirments.. D. MOUNT PULL STATIONS AT 46.48"A.F.F.TO THE OPERATING HANDLE TO MEET ADA REQUIREMENTS. Allowed Interior Lighting Power o06 arlchitect provisions mechanical and plumbing systems can not be 9. CUTTING AND PATCHING: provided with typed writtend directories E. IN CORRIDORS,NOTIFICATION APPLIANCES MUST BE LOCATED WITHIN 16 FROM ENDS OF A B c D *IF ELECTRICAL WORK IS \ Panelbards:Shall be r YP Do all drilling and cutting as necessary for installation of Maintain loads being SBNefc Area Category Floor Area Allowed Allowed wane l� shown.All installations shall be adjusted as necessary to 9 9 CORRIDORS AND OF 100'SPACING. BEING DONE BY OTHERS equipment or conduit.Cutting or drilling of structure is only Maintain all re ulred clearances around equipment as Inzl wane/ftz (e x c> conform and to avoid obstructions,without additional cost to q eQ P �i permitted with prior approval of the owner and structural required the NEC. F. PROVIDE THE REQUIRED CANDELA RATING OF ALL NOTIFICATION APPLIANCES ACCORDING TO ROOM vschoouum�ersnr 2860 c.e1 z0n THEN THEY MUST HAVER the owner. q Y engineer. SIZE ETC. All work,material and equipment called for by notes, g All equpment dimensions[o be field verified. Talal discoed wam• 2017 TF ELECTRICAL PERMIT V Ira Where cutting and patching of work is necessary,use the G. NOTIFICATION APPLIANCES TO BE SYNCHRONIZED TO PROVIDE A 3-3-3 TEMPORAL PATTERN. schedules or otherwise indicated on the drawings Shall be same materials,workmanship and finish to neatly match all 17.CLEAN-UP: Proposed Interior Lighting Power BEFORE STARTING WORK r-.1 Iil z furnished and inntalled as though fully set forth in these U on comic lesion of the work,prior to final inspection, H. ALL APARTMENT UNITS SHALL BE PROVIDED WITH MULTI-STATION SMOKE DETECTORS AND LOW „y surrounding work. P P P P A e c D E O specifications. thoroughly clean all exposed fixtures,trim and equipment FREQUENCY NOTIFICATION DEVICES IN COMPLIANCE WITH NFPA 72,ADA UNITS SHALL BE PROVIDED Fixture ID:Description I Lamp/Wattage Per Lamp/Ballast Lampsl pot Fixture (O x D) 4. VISITING THE SITE: 10.CONDUIT: and leave the entire installation in a neat,clean and usable WITH AUDIBLE AND VISIBLE NOTIFICATION DEVICES. Fixture Fixtures Wen. All conduit material and installation methods shall be as condition.Remove all cement,paint,grease,oil and other I. ALL NOTIFICATION DEVICES LOCATED IN SLEEPING ROOMS SHALL BE 177 CANDELA. FG Contractor shall visit the site and become acquainted with Se�onuunive.aity 2aso so%1 r) M allowed by the NEC,local AHJ and as directed by the foreign substances. conditions to be encounterd.Extra funds will not be allowed J. PROVIDE ALL REQUIRED MONITORING,INITIATION DEVICESAND INTERCONNECTIONS FOR LEo 1:F1:zFr Len STRIP:rnher. 1 1 15 15 rl a due to failuer to examine the site and to included existing 18.TEST: ELEVATORS,COMMERCIAL KITCHEN HOODS AND FIRE SPRINKLER RISER(S). LED z:FVF2s:4Fr Leo wRAPARouNO:ether: 1 1g so g50 f�" M conditions in bid price. 11.CONDUCTORS: Test all conductors for shorts,opens, rounds or other LED 2xpy 1:E05:8"LED WRAPAROUND M. 1 19 60 1140 P 9 K. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR ALL MONITORING POINTS OF FIRE SPRINKLER Twal Pmp4eed Watts zlos Type THWN or THHN copper wire insulated for BODY. defects.Correct any defective work and re-test. 5. COORDINATION WITH UTILITIES: SYSTEM. These lens have been prepared without unlit company Smallest wire shall be per AWG unless noted otherwise. Demonstrate continuous satisfactory operation of all P P P Y P Y L. PROVIDE AUTOMATIC SHUT DOWN WITH DUCT SMOKE DETECTORS FOR ALL HVAC EQUIPMENT - •' comments.The contractor shall verify exact requirements for All wiring shall be Copper unless indicated otherwise. electrical systems and equipment. the electrical,telephone and communication services with the Type MC cable shall be permitted,provided it is installed in Provide training to the owner on electrical systems as GREATER THAN 2000 GEM. Interior Lighting Compliance Statement CITY APPROVED PLANS 1 utility company representatives and provide all work and pay concealed areas and installation complies with the Local AHJ needed for owner operation and maintenance of building. compliance statement:The proposed interior lighting alteration project represented in this document is consistent with the I� and NEC requirements. building plans,specifications,and other calculations Submitted with this permit application.The proposed interior lighting r� all costs for a complete and operating systems,as directed by 19.GUARANTEE: systems have been designed to meet the 2018IECC requirements In COMcheck vemlon 4.1.5.5 and W comply with any Reviewed for Code Compliance the governing utilities. Prior to final acce tacne of the project, applicable mandatory req.-ments listed in the Inspection Checklist. Use"Ideal Yellow"pulling compound for all wire pulls. P p lest,deliver to the owner 6. MATERIALS AND WORKMANSHIP: Use Scotchlock connectors for all splices in#12 wire and a wrinen one year guarantee on all workmanship,materials Sham Meador,PE � 12Po42023 PLANS MUST BE ON JOB SITE All workmanship shall be performed by skilled electricians tape bolted pressure connectors for larger wire. and equipment and agree to repair or replace all such Name-idle signature Date using the best standard practives of the trade.All materials defective items promptly that may occurs during the FOR ALL INSPECTIONS Shall,unless otherwise noted,be new and in perfect warranty period;including repair or replacement of the condition and working order.All material for similar uses shall 12.GROUNDING: premises that may be damaged due to faulty work and be of the same type,material and manufacturer for ease of All conduit,branch circuits,feeders and etc.shall be materials furnished under contract. future maintaenance. provided with a grounding conductor.All grounding DATE: 12/4/23 All equipment shall be readily accessible for maintenance and conductors shall be insulated and green in color,size as repairs.All materials,fixtures and equipment shall be shown. SAM TEP covered or sealed upon installation so as to provide for safety PROJECT#:23118 r-,o cha<kaa and to insure that operation and appearance will be �SS�Q NAL E4,Gi #23047 maintained after subsequent construction operations. `c P�G1STEq ��• �PAYNE' PFC ECT# Proiect Title: E-STREET COMMUNITY CENTER-REMODEL Reportdate:11t3023 �13053o Engles g Inc. EO■O atello,Idaho 12/4/23 1823 E.Center `' )Tq OF t�P�O .1 c(208 232 4439 201 qk'N A.MEP www.payneengineeringinc.com Page 23 of 29 GENERAL NOTES: A. ALL EXISTING ELECTRICAL MAY NOT APPEAR ON THESE PLANS,HOWEVER THE ABOVE INFORMATION APPLIES. B. PROVIDE AND INSTALL BLANK COVERS ON ALL UNUSED SWITCH/OUTLET/J-BOXES WHERE REQUIRED. C. ALL WALL DEVICES THAT ARE EXISTING TO REMAIN,SHALL BE ADAPTED TO NEW WALL COVERINGS,REFER TO ARCHITECTURAL DRAWINGS FOR EXACT WALL LOCATIONS, THICKNESS,ETC, D. PRIOR TO THE START OF ANY DEMOLITION WORK, DISCONNECTING ANY POWER AND OR TELE/DATA SYSTEMS, THE CONTRACTOR SHALL COORDINATE DOWN-TIME WITH THE OWNER. E. REFER TO ARCHITECTURAL PLANS FOR EXTENT OF DEMOLITION,DETAILS,ETC. F. REMOVE OR RELOCATE ELECTRICAL AS NECESSARY FOR NEW WORK. G. WHERE EXISTING CIRCUITS ARE TO BE RE-USED,EXTEND AS NECESSARY.MAINTAIN ELECTRICAL CONTINUITY TO DOWNSTREAM EQUIPMENT TO REMAIN. H. EXISTING SHOWN TO REMAIN,MAY NEED TO BE REMOVED AND RE-INSTALLED ONLY AS NECESSARY FOR EXTENDING OR MODIFICATION OF EXISTING CIRCUITS OR WIRING. I. REFER TO MECHANICAL PLANS FOR EXTENT OF MECHANICAL EQUIPMENT TO BE REMOVED OR RELOCATED. J. REMOVE ALL UNUSED EQUIPMENT WIRING,CONDUIT AND BOXES IN ALL AREAS.ABANDON ONLY IN CONCEALED AREAS. K. CONTRACTOR MY UTILIZE ANY EXISTING CONDUIT WHERE COMPATIBLE WITH NEW DESIGN,AND IF IN GOOD CONDITION AND COMPLIES WITH SPECIFICATIONS. L. WHEN ANY MODIFICATIONS ARE MADE TO ANY EXISTING ELECTRICAL PANEL TO REMAIN,CONTRACTOR TO PROVIDE NEW TYPE WRITTEN INDEX TO REFLECT ALL NEW AND EXISTING LOADS. M. REMOVE ALL EQUIPMENT,RACEWAYS,CABLES,ETC.NOT USED IN FINISHED AREAS. KEY NOTES: z , ALL EXISTING ELECTRICAL EQUIPMENT,DEVICES,LTG,ETC Q WITHIN THIS AREA IS TO BE DISCONNECTED AND REMOVED TO ACCOMMODATE NEW CONSTRUCTION.E.0 SHALL FIELD J LOCATED EXISTING CIRCUIT TO BE REUSED FOR NEW Q CONSTRUCTION,E.C.SHALL MAINTAIN/RE-ESTABLISH U CONTINUITY TO ALL DOWNSTREAM EQUIPMENT/DEVICES THAT ARE TO REMAIN. 2 EXISTING 3/4"CONDUIT MOUNTED TO EXISTING WALL SHALL BE RE-ROUTED HIGHER ON WALL TO ACCOMMODATE NEW U CONSTRUCTION,FIELD VERIFY ROUTING OF CONDUIT WITH ir LL REMODEL. 0 J 3 ALL EXISTING ELECTRICAL DEVICES,ETC ON THIS WALL TO BE LL LU REMOVED AND/OR RELOCATED TO ACCOMMODATE NEW z J CONSTRUCTION.E.C.SHALL MAINTAIN/RE-ESTABLISH O Q CONTINUITY TO ALL DOWNSTREAM EQUIPMENT/DEVICES LL cr THAT ARE TO REMAIN. �4 EXISTING LIGHTING AND CONTROLS IN THIS ROOM TO BE N z Z ; REPLACED WITH NEW,UTILIZED EXISTING LIGHTING CIRCUIT _ F AND MODIFY AS REQUIRED. z o O 6 EXISTING LIGHTING CONTROLS TO BE RELOCATED TO cr ~ m ACCOMMODATE NEW CONSTRUCTION,EXTEND EXISTING W W w Z CONDUIT/CONDUCTORS TO NEW LOCATION AS REQUIRED TO Q NO WORK MAINTAIN ORIGINAL FUNCTIONALITY. O IN THIS 6 EXISTING ELECTRICAL PANEL TO REMAIN,E.C.SHALL FIELD ,L NO WORK AREA LOCATE AND PROTECT DURING CONSTRUCTION. X INTHIS 7 EXISTING EQUIPMENT TO BE REMOVED,E.C.SHALL Q LLI LL r----�T----� AREA NO WORK DISCONNECT/REMOVE/RELOCATE EXISTING RECEPTACLES AS `--- ----� NO WORK INTHIS NEEDED FOR NEW EQUIPMENT,SEE NEW ELECTRICAL PLANS. INTHIS AREA 8 EXISTING CEILING FANS SHALL BE RECIRCUITED AS AREA REQUIRED TO PROVIDE DEDICATED SWITCH FOR CONTROL OF FANS,SEE NEW ELECTRICAL PLANS. NO WORK --- r _ _'� INTHIS I II AREA ' ' y NO WORK ----� A, NIN WORK 4/ R THIS i NO WORK ---- ---- IN __ 6 AREA INTHIS r �r o I AREA _ _ _ _ NO WORK ��� AREA pp IN THIS i i I NO WORK ° - - Al AREA IN THIS _ _ _ yyy,,,I,(((�II &9 o �,V♦ AREA _2 1=� �✓ �cn - NO WORK � 5 INTHI AREAS NO WORK - NO WORK - 2 3 ®� 1 INTHIS 1 INTHIS b AREA +n AREA O L•I O NO WORK O Li IN THIS \ NO WORK I,IN THIS - 4 ❑ AREA F O AREA - - - NO WORK IN THIS rl W AREA r' O NO WORK NO WORK a. INTHIS INTHIS rl ( A AREA ` AREA pB' NO WORK INTHIS q I AREA I I�_ I-AT _ - CITY APPROVED PLANS r e ' � � I Reviewed for Code Compliance NO WORK INTHIS PLANS MUST BE ON JOB SITE AREA FOR ALL INSPECTIONS II I it I I SAM TEP �55�0 NAL E,vGi PROJECT#:23118 or�n #23047 STE PROJECTp cn�k�a n EXISTING OVERALL ELECTRICAL PLAN P�GtAF"F �PAYNE o En iCwter Inc. 0" 8' 16, 13053 g g 12/4/23 1823 E..Center EO.1 SHTq/F OF Po 208c 232 Idaho 8 201 telqk'N q,MEND www.payneengineeringinc.com Page 24 of 29 GENERAL NOTES: A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH THE INSTALLATION OF EACH SYSTEM,INCLUDINB BUT NOT LIMITED TO;LIGHTING,POWER,FIRE ALARM,SPECIAL SYSTEMS,ETC. EXIT signage needed in this exterior area as well. This is a relativity small area that three doors exit to.The path EXPOSED RACEWAY SPECIAL NOTES: to the left is NOT clearly defined. Ii ALL NEW CIRCUITING,LOW VOLTAGE CABLING,FIRE ALARM CABLING AND ETC.INSTALLED IN EXISTING BUILDING SHALL BE CONCEALED IN WALLS,FLOORS,PIPE TUNNELS AND CEILINGS WERE POSSIBLE.WHERE CABLING/WIRING CANNOT BE CONCEALED IT SHALL BE INSTALLED IN CONDUITANIREMOLD IN ALL FINISHED AREAS OF EXISTING BUILDING.RACEWAY SHALL BE ROUTED IN A weaR PROFESSIONAL MANNER AT 90 DEG.ANGLES TO STRUCTURES.INSTALL RACEWAY IN LOCATIONS TO MINIMIZE VISUAL APPEARANCE AS MUCH AS POSSIBLE. F2S F3S NO WORK ALL EXPOSED RACEWAY SHALL BE PAINTED TO MATCH IN THIS NO WORK SURFACE IN WHICH IT IS INSTALLED. AREA INTHIS AREA SURFACE MOUNTED RACEWAY IN FINISHED AREAS OF NEW ADDITION IS PROHIBITED. < F2S F14 KIZA KEY NOTES: No// 1 EXISTING LIGHTING CONTROLS TO BE RELOCATED TO 7/z ACCOMMODATE NEW CONSTRUCTION,EXTEND EXISTING CONDUIT/CONDUCTORS TO NEW LOCATION AS REQUIRED TO Q 1 MAINTAIN ORIGINAL FUNCTIONALITY. 1 2 CONNECT TO EXISTING LIGHTING CIRCUIT THAT ORIGINATED E (E) IN ROOM MADE AVAILABLE FROM DEMOLITION,E.C.SHALL (E) E FIELD VERIFY HOMERUN LOCATION. F2S F. c M 7N. E) EI (E) WALK IN 2 Ir l o / o FREEZER KITFZEN � J E AND TYP) LBUIL. K NO WORK COOLER(EI INTHIS - (E) AR EA i ING (E (E) 1 0 WORK z F2S F3S (E (E NTHIS O Q AREA 0 O FX2 ILL z a 3 (E) (E) (E (E r - - _Q z LL NO WORK ~ z (E c IN THIS N 2 AREA F 0 i F%1 z J J F 1 (E) (E) (E Cr Lu Lu m i LU LUcr m Q F3S sTc Q - N Q (TYP) w LU � F2S F2S i Q LLI Q NO W0� 12 IN THI O OREA orrice i Fit NO WORK (E) (E) sTG INTHIS REA � NO WOR F2S IN THIS NT O � NO WORK �r N THIS O ARE RR F1 weaR F2S i EI (E) r♦ •�" � (e) (E (E) cwLORR NO WORK '~ ono F3S NO WOR INT(Typ) HIS (AREA tt.m AREA � � '3 0 KEY PLAN H�' weaR wasR weaR ?-I U Q a C ROOM L 1-d 2 r� M 3 NO WORK F3S O F3S IN THI FX1 F3S O C") (TYP) REA lam) AREAA AREAB DATE: 12/4/23 SAM TEP o,H«a cna<kra CITY APPROVED PLANS F�sSGtSTefv�m PROJECT#:23118 a23oa� P� �� � �PAYNE PROJe°T" AREA A-LIGHTING PLAN Reviewedfoc Code Compliance 13053 En Ineerin 9 Inc. � 9 0" 4' g' ® PLANS MUST BE ON JOB SITE s 12/q/23 O 1823 E.Center E1 .0 NORTH FOR ALL INSPECTIONS `rH,y OF�OP�O el(208)232 4439 201 k'N q,MEP www.payneengineeringinc.com Page 25 of 29 ADDITIONAL NAC AMPLIFIER PANELSS KITCHEN EQUIPMENT SCHEDULE DATA CABLING SYSTEM DESIGN: GENERAL NOTES: AS NEEDED,INSTALL ITEM# EQUIPMENT DESCRIPTION VOLTS PH. AMPS PANEL CIRCUIT FEEDER CONNECTION TYPE NOTES A. E.C.SHALL REFER TO FOOD SERVICE DRAWINGS(FS)FOR IN ELEC.ROOMS NEW TYPICAL NOTIFICATION 1CC COOLER CONDENSING UNIT 208 V 1 12 A K 32,34 #12's+GND DIRECT 1,5,6,7 DATA CABLING SYSTEM SHALL BE DESIGN BUILD BY THE ADDITIONAL REQUIREMENTS AND SPECIFIC ELECTRICAL UL 864 FIRE ALARM& APPLIANCE CIRCUIT 10E COOLER EVAPORATOR UNIT 120 V 1 2 A K 30 #12's+GND DIRECT 1,5,6,7 ELECTRICAL CONTRACTOR AS DIRECTED BY THE OWNER. ROUGH-IN AND CONNECTION REQUIREMENTS FOR KITCHEN CELLULAR VOICE EVAC. (STROBES) 1FC FREEZER CONDENSING UNIT 208 V 1 26 A K 40,42 #8's+GND DIRECT 1,5,6,7 E.0 SHALL COORDINATE LOW VOLTAGE SYSTEM O PANEL(S) REQUIREMENTS WITH THE OWNER PRIOR TO CONSTRUCTION EQUIPMENT. ALARM FANEP 1FE FREEZER EVAPORATOR UNIT 208V 1 8A K 36,38 #12'S+GND DIRECT 1,5,6,7 COMM. ( ) TYPICAL NOTIFICATION 9 ICE MAKER 120 V 1 7 A K 5 #12's+GND NEMA 5-20R 1 AND PROVIDE ALL REQUIRED RACEWAY,OUTLETS,CABLING, B. ALL 120V,15A AND 20A RECEPTACLES INSTALLED IN THE APPLIANCE CIRCUIT 13 REFRIGERATED MECHANDISER 120V 1 3A K 1 #12's+GND NEMA 5-20R 1 ETC AS DETERMINED AND DIRECTED BY THE OWNER. KITCHEN AREA SHALL BE GFCI TYPE RECEPTACLES.IF (SPEAKERS) 14A ELECTRIC COMBO OVEN 208 V 3 62 A K 37,39,41 #4's+GND HARD-WIRED 1 RECEPTACLE IS NOT READILY ACEESSIBLE,FURNISH GFCI TYPICAL INITIATING 14B ELECTRIC COMBO OVEN 208V 3 62A K 31,33,35 #4's+GND HARD-WIRED 1 TYPE BREAKER TO SUPPLY RECEPTACLE CIRCUIT. DEVICE CIRCUIT O O O TS FS MM 15 PROOFER CABINET 120 V 1 3A K 3 #12's+GND FIELD VERIFY 1 C. E.C.SHALL UTILIZE CONDUIT SEAL-OFF FOR ALL CONDUIT (SLC LOOP) D H P KITCHEN EQUIPMENT SCHEDULE NOTES: ROUTED THROUGH FREEZER/COOLERS AS REQUIRED BY CLASS B TO ADDITIONAL RM CM THE NEC. FIRE ALARM SYSTEM NOTES: ADDRESSABLE 1. E.C.SHALL COORDINATE MTG HEIGHT AND ROUGH-IN REQUIREMENTS WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN. • FIRE ALARM SYSTEM CONDUIT ROUTING SHALL BE DEVICES 2. PROVIDE WITH LOCK-OUT TYPE BREAKER IN PANEL. RM DETERMINED BY THE ELECTRICAL CONTRACTOR AND 3. UTILIZE SHUNT-TRIP BREAKER FOR EQUIPMENT,CONTROL VIA KITCHEN HOOD ANSUL SYSTEM.4 AL DE E RM NEE B CONTRACTORTOR T I MEET SPECIFIED 4. E.C.SHALL PROVIDE AND INSTALL FUSED DISC.AT UNIT;FUSE PER EQUIPMENT NAMEPLATE. EXPOSED RACEWAY SPECIAL NOTES: DESIGN CRITERIA. REMOTE ANNUNCIATOR(S)WITH 5. PROVIDE REQUIRED CONDUIT SEAL-OFF FOR ALL PENETRATIONS INTO WALK-IN COOLER/FREEZER;COORDINATE WITH EQUIPMENT SUPPLIER. Separate Mechanical Hood Permit • ALL FIRE ALARM SYSTEM CABLING SHALL BE RUN IN RA/MIC MICROPHONE 6. E.C.SHALL PROVIDE AND INSTALL HEAT-TRACE FOR FREEZER LINES;COORDINATE LENGTHS WITH KITCHEN EQUIPMENT SUPPLIER. required to Install new hood and ALL NEW CIRCUITING,LOW VOLTAGE CABLING,FIRE ALARM CONDUIT ORRM SYSTEM WHERE SURFACE MOUNTED (VERIFY LOCATION WITH LOCAL AHJ) 7. PROVIDE CONDUIT AND CONDUCTORS BETWEEN COOLER/FREEZER EVAPORATOR AND CONDENSER AS REQUIRED BY MANUFACTURER. suppression Systems. CABLING AND ETC.INSTALLED IN EXISTING BUILDING SHALL RACEWAY MUST BE INSTALLED IN EXISTING FINISHED 8. PROVIDE CONNECTION TO KITCHEN HOOD CONTROL PANEL;PROVIDE ALL REQUIRED CONNECTIONS TO;LIGHTING,GAS SHUT-OFF AND ETC. BE CONCEALED IN WALLS,FLOORS,PIPE TUNNELS AND SPACESCOORDINATE WITH HOOD INSTALLER&SHOP DRAWINGS. CEILINGS WERE POSSIBLE.WHERE CABLING/WIRING • CONTRACTOR SHALL PROVIDE ADDITIONAL POWER CM MECH.EQUIP. 9. E.C.IS RESPONSIBLE FORALL REQUIRED CONNECTIONS BETWEEN HOOD EXHAUST/SUPPLY FANS AND HOOD CONTROL PANEL.COORDINATE Once structural,mechanical, CANNOT BE CONCEALED IT SHALL BE INSTALLED IN FAN SHUT DOWN WITH SHOP DRAWINGS. electrical and plumbing InSpeCtIOnS CONDUIT/WIREMOLD IN ALL FINISHED AREAS OF EXISTING SUPPLY AND AMPLIFIER PANELS WHERE REQUIRED TO MEET THE SPECIFIED DESIGN CRITERIA. GENERAL KITCHEN EQUIPMENT NOTES: have been Completed,contact the BUILDING.RACEWAY SHALL BE ROUTED IN A • CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND D DOOR HOLDER TF Fire Marshal's office to request PROFESSIONAL MANNER AT 90 DEG.ANGLES TO REQUIRED CALCULATIONS TO THE AUTHORITY HAVING CIRCUIT REFER TO KITCHEN CONSULTANT DRAWINGS FOR ADDITIONAL INFORMATION AND ELECTRICAL REQUIREMENTS. the fire final trip test. STRUCTURES.INSTALL RACEWAY IN LOCATIONS TO < JURISDICTION AND OBTAIN A WRITTEN LETTER OF REFER TO KITCHEN HOOD SHOP DRAWINGS FOR ADDITIONAL INFROMATION AND ALL REQUIRED ELECTRICAL CONNECTIONS. MINIMIZE VISUAL APPEARANCE AS MUCH AS POSSIBLE. ACCEPTANCE OF THE PROPOSED SYSTEM.INCLUDE 120V CIRCUIT LETTER WITH SHOP DRAWING SUBMITTAL TO ENGINEER. Fire Inspection Line:208-7355-7338 ALL EXPOSED RACEWAY SHALL BE PAINTED TO MATCH • E.C.SHALL PROVIDE AND INSTALL CELLULAR ALARM SURFACE IN WHICH IT IS INSTALLED. o COMMUNICATOR FOR FIRE ALARM SYSTEM MONITORING, TELGUARD TG-7FS LTE OR EQUAL.SYSTEM SHALL BE UL SURFACE MOUNTED RACEWAY IN FINISHED AREAS OF NEW LISTED AND COMPLIANT WITH NFPA 72 ADDITION IS PROHIBITED. REQUIREMENTS.PROVIDE(1)YEAR RENEWABLE CELLULAR SERVICE COORDINATE SERVICE PROVIDER WITH OWNER. A M (VOICE EVAC.) MECH.-ENERGY RECOVERY UNIT SCHEDULE O KEY NOTES: SCALE:NONE EQUIP.ID VOLTS/PH. MCA MOCP CIRCUIT FEEDER DISCONNECT NOTES 1 EXISTINGCONDUIT MOUNTED TO EXISTING WALL SHALL ERV-1 120v, 0 V/1 PH. 9 A 15 A B-50 1/2"C.,2#12+1#12G 30 A-NONFUSED/1 3 BE RE-ROUTED HIGHER ON WALL TO ACCOMMODATE NEW 71 CONSTRUCTION,FIELD VERIFY ROUTING OF CONDUIT WITH z MECH. - ELECTRIC HEATER SCHEDULE 2 REMODEL. O i RECEPTACLE MOUNTED TO HVAC UNIT,COORDINATE J P EQUIP.ID VOLTS/PH. WATTS FLA CIRCUIT FEEDER NOTES MOUNTING WITH M.C.PRIOR TO ROUGH-IN. NO WOR EH-1 120V/l PH. 1000W 8A B-48 1/2"C.,2#12+1#12G c IN THIS G AREA 6E ILL! 0 MECH.-WATER HEATER SCHEDULE 0 O EQUIP.ID VOLTS/PH. WATTS FLA CIRCUIT FEEDER DISCONNECT NOTES ILL } P RP-1 120 V/1 PH. 50 W O A B-53 1/2"C.,2#12+1#12G CORD/PLUG z (n FC-1A • K'2 WH-2 208 V/1 PH. 4500W 22A K-26,28 3/4"C.,2#10+1#10G 30A-NONFUSED/1 3 O K4 O F LL LU ✓ILV FREEZER MECH. -HEAT PUMP SCHEDULE N 0 OFC3B K-8 ® 1FE ® DOOR\ K$ EQUIP.ID VOLTS PH. MCA MOCP CIRCUIT FEEDER DISCONNECT NOTES z P (E)OFFICE (E)OFFICE LTG HTR 14A 2 K-2 14B 13 HP-1 208V/1 PH. 21A 25A K-19,21 3/4"C.,2#10+1#10G 30A-NONFUSED/3R 3,4 U-1 = i anssRooM K-g 03, WHP-3 O CD OO HP-2 208V/1 PH. 21A 25A K-23,25 3/4"C.,2#10+1#10G 30A-NONFUSED/3R 3,4 tJ_I Lu w Q HIP O Qp C. FC-3C OOP ION ncoFl H H 15 HP-3 208 V/1 PH. 31 A 35 A K-27,29 34'C.,2#8+1#1OG 60 A-NONFUSEDl3R 3A O Q LLJ " P OP ® ,DQ MECH.-FAN COIL UNIT SCHEDULE 2 U) IT K K-2 KITCHEN Q W Q EQUIPMENT COOLER ®LTG EQUIP.ID VOLTS/PH. MCA CIRCUIT FEEDER DISCONNECT NOTES ® 10E AC FC-3D AC 9 FC-1A 208 V/1 PH. 0.32A K-20,22 1/2"C.,2#12+GND PROVIDE LOCAL DISC. OO FC-1B 208V 11 PH. 0.32A K-20,22 1/2"C.,2#12+GND PROVIDE LOCAL DISC. p _ NO FC-2A 208V/1 PH. 0.32A K-20,22 1/2"C.,2#12+GND PROVIDE LOCAL DISC. ° HE S N THIS FC-2B 208 V11 PH. 0.32A K-20,22 1/2"C.,2#12+GND PROVIDE LOCAL DISC. HEATSMO O FFavme11 lrvsTai IN CORR2 K4 ARE FG-3A 208V/1 PH. 0.15A K-20,22 1/2"C.,2#12+GND PROVIDE LOCAL DISC.EETECiONS O p nunccEsslsLE nnlc uJo vEmxNE p FC-3B 208 V11 PH. 0.15A K-20,22 1/2"0,2#12+GND PROVIDE LOCAL DISC. QP 1 ————— naEns ns osFwso EVNEFanaNOIEC FC-3C 208V/1 PH. 0.15A K-20,22 1/2"C.,2#12+GND PROVIDE LOCAL DISC. CORR3 FC-3D 208V/1 PH. 0.32A K-20,22 1/2"C.,2#12+GND PROVIDE LOCAL DISC. A� FCFCIB I FC-3A ®WH-2 I 4/ &53 nN aEa B-51 a MECH. - EXHAUST FAN SCHEDULE B-53 D Op I EQUIP.ID VOLTS/PH. HP WATTS FLA CIRCUIT FEEDER 1 CONTROL NOTES U Op Op B-53 s c CLnssaooM EF-1 120 V/1 PH. N/A 10O W 1 A 1/2"C.,2#12+1#12G I OCC.SENSOR 1 I 3 MECHANICAL SCHEDULE NOTES: bA M �l o RP-1 M QI OP I OP OOP OP OO p 1. CONNECT TO LIGHTING CIRCUIT IN ROOM,CONTROL WITH DEDICATED OCCUPANCY SENSOR AS , o p OFFICE g-404P INDICATED. U A _ I .d B-43 #10's TO FACP 2. E.C.SHALL PROVIDE LOCAL DISCONNECT RATED,THERMAL-OVERLOAD SWITCH FOR EQUIPMENT; 3 I SWITCH RATING SHALL NOT BE LESS THEN CIRCUIT BREAKER SUPPLYING EQUIPMENT. ,�/•� o B-39,41 'RA/MIC' 3. E.C.SHALL PROVIDE LOCAL DISCONNECT SWITCH FOR EQUIPMENT;SIZE AND TYPE AS INDICATED i.d.l ly EH-1 I B44 #10's I (A/E7.1) N WHIR M g$1 3 IN THIS 1 �I IN SCHEDULE.IF FUSED DISCONNECT IS SPECIFIED FOR EQUIPMENT,FUSE PER EQUIPMENTal OO I AREA NO WORK NAMEPLATE RATING. A 3 0 Oo p ®ERV_1 g sc P i IN THIS 4. PROVIDE 1/2"CONDUIT AND CONDUCTORS BETWEEN FURNACE AND CORRESPONDING OUTDOOR KEY PLAN �•I �.+ ceaoRaxNEIIrp�Ep AREA CONDENSING UNIT.COORDINATE SIZE AND NUMBER OF CONDUCTORS WITH M.C.PRIOR TO U V 01 B-53 __ __(A/E7.1) ROUGH-IN.PROVIDE CONNECTION BETWEEN FURNACE AND ASSOCIATED OUTSIDE AIR 6W V1 B-54 MOTORIZED DAMPER,COORDINATE WITH M.C. 5. INDOOR UNIT IS POWERED FROM OUTDOOR UNIT;COORDINATE EXACT NUMBER OF CONDUCTORS oz coRRa OO BETWEEN UNITS WITH M.C.PRIOR TO ROUGH-IN.Op P K$ 2 WP M B51 M �`--'� HP 2 FC-213 �9 FC-2A B-47,49 cox RooFl (Z I I I I I�B O S-47 O O O O P P P P P P v T u el O O P CL4S ZROOM B49 P p NO WORK AREAA IN THIS AREA B AREA DATE: 12/4/23 B-47 B-47 B47 B49 14p W CITY APPROVED PLANS BAM TEP 0r�" �Sg\O NA(F,vG/ PROJECT#:23118 #23047 CN�x� Reviewed for Code Compliance F P�G\STEq HF �PAYNEI PI—ECTx PLANS MUST BE ON JOB SITE 13053 Engi�t'rin9 Inc. In AREA A- POWER/SYSTEMS PLAN FOR ALL INSPECTIONS s 12/4/23 p 1823 E.Center E1 .1 SCALE:3/16"=1'-0" 0" 4' 8' SHTq/F OF 10P�0 .1 c(208 2 2 4439 atello,Idaho 201 NORTH qk'N A.MENO —payneengineeringinc.com Page 26 of 29 GENERAL NOTES: LIGHTING FIXTURE SCHEDULE A. REFER TO SYMBOL SCHEDULE SHEET FOR PROJECT COLOR APPROVED GENERAL NOTES AND GENERAL NOTES ASSOCIATED WITH TYPE DESCRIPTION MOUNTING VOLTS WATTS LUMENS TEMP.(K) MFGR. CATALOG# MFGR'S NOTES THE INSTALLATION OF EACH SYSTEM,INCLUDINB BUT NOT F1 2FT LED STRIP,0-10V DIMMING SURFACE 120-277 15 W 2000 4000 LITHONIA CLX-L24-2000LM-SEF-RDL-MVOLT-GZ1040K-80CRI COOPER LIMITED TO;LIGHTING,POWER,FIRE ALARM,SPECIAL F2 4FT LED WRAPAROUND,0-10V SURFACE 120-277 SOW 6000 4000 LITHONIA BLWP4-60L-ADP-EZ1-LP840 1 SYSTEMS,ETC. DIMMING F2S 4FT LED WRAPAROUND,0-10V SURFACE 120-277 40 W 4000 4000 LITHONIA BLWP440L-ADP-EZI-LP840-nLIGHTAIR2 RES7PDT 1,2 DIMMING,INTEGRAL nLIGHT AIR WIRELESS SENSOR F3S 8FT LED WRAPAROUND,0-10V SURFACE 120-277 60W 8000 4000 LITHONIA BLWP8-80L-ADP-EZ1-LP840-nLIGHTAIR2RES7PDT 1,2 EXPOSED RACEWAY SPECIAL NOTES: DIMMING,INTEGRAL nLIGHT - - -- - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - AIR WIRELESS SENSORI I I I I ALL NEW CIRCUITING,LOW VOLTAGE CABLING,FIRE ALARM FX1 EXIT SIGN/EM LIGHT COMBO W/ WALL OR 120-277 2 W N/A N/A LITHONIA LHOM LED-G-SD COOPER CABLING AND ETC.INSTALLED IN EXISTING BUILDING SHALL 90MIN CEILING BE CONCEALED IN WALLS,FLOORS,PIPE TUNNELS AND BA TTERY,THERMOPLASTIC, CEIL INGS WERE POSSIBLE.WHERE CABLING/WIRING GREEN LED,SINGLE/DOUBLE CANNOT BE CONCEALED IT SHALL BE INSTALLED IN FACE CONDUITANIREMOLD IN ALL FINISHED AREAS OF EXISTING NO WORK FX2 WALL MOUNTED LED WALL AT 120-277 3 W N/A N/A LITHONIA ELM6L-UVOLT-LTP-SDRT COOPER BUILDING.RACEWAY SHALL BE ROUTED IN A N THIS EMERGENCY LIGHT 7'-6"AFF PROFESSIONAL MANNER AT 90 DEG.ANGLES TO AREA LIGHT FIXTURE SCHEDULE NOTES: STRUCTURES.INSTALL RACEWAY IN LOCATIONS TO MINIMIZE VISUAL APPEARANCE AS MUCH AS POSSIBLE. AVE 0-10V OR STEP-LEVEL DIMMING CONTROL.PROVIDE FIXTURE(S)WITH LED DRIVER(S)AND REQUIRED 1. REFER TO DRAWINGS FOR FIXTURES REQUIRED TO H DIMMING/SWITCH-LEG CONDUCTORS BETWEEN SWITCH(ES)AND FIXTURE(S)TO PROVIDE CONTROL AS INDICATED ON DRAWINGS. ALL EXPOSED RACEWAY SHALL BE PAINTED TO MATCH - - - - - - - - - - - - - - - - - - - - - - - - 2. FIXTURE TO BE CONTINUOUS ROW MOUNTED,LENGTH AS INDICATED ON DRAWINGS.PROVIDE REQUIRED ACCESSORIES/CONNECTORS FOR CONTINUOUS SURFACE IN WHICH IT IS INSTALLED. ROW MOUNTING. W83R 3. SCBA-STANDARD COLOR BY ARCHITECT/OWNER(COORDINATE COLOR WITH ARCHITECT/OWNER PRIOR TO ORDERING.) SURFACE MOUNTED RACEWAY IN FINISHED AREAS OF NEW F2S • ADDITION IS PROHIBITED. F3S i GENERAL LIGHTING SCHEDULE NOTES: EF-1 P , LIGHTING FIXTURES INDICATED IN SCHEDULE ARE BASIS OF DESIGN,ALTERNATE MANUFACTURERS SHALL BE PRE-APPROVED BY ADDENDUM. O O ALTERNATE MANUCATURERS SHALL SUBMIT PER-APPROVALS TO ENGINEER A MINIMUM OF 10 DAYS PRIOR TO PROJECT BID DATE. O KEY NOTES: W2 S F3S 1 - ADARR 1 CONNECT TO EXISTING LIGHTING CIRCUIT THAT ORIGINATED IN ROOM MADE AVAILABLE FROM DEMOLITION,E.C.SHALL I a ys, LIGHTING CONTROL/OCCUPANCY SENSOR SCHEDULE FIELD VERIFY HOMERUN LOCATION. NO WOR IEI WOMEry NO WORK ) '") APPROVED 2 CONNECT TO EXISTING RECEPTACLE CIRCUIT IN AREA MADE IN THIS RR TYPE DESCRIPTION MFGR. CATALOG# EQUALS NO7ES AVAILABLE FROM DEMOLITION. AR AR OCC.SENSORS-CEILING(LINE VOLTAGE) ' [CF2 DUAL-TECHNOLOGY,LINE VOLTAGE,SMALL MOTION BOOW MAX LOAD SENSOR SWITCH CMR PDT 9 COOPER, - :.. WATTSOPPER, HUBBELL T WIRELESS CONTROLS WB3R I nLIGHT AIR WIRELESS 3-BUTTON BATTERY-POWERED SWITCH,ON/OFF, ACUITY BRANDS rPODBA DX-'G2 WAVE LINX LITE 2 RAISE/LOWER DIMMING U) CONTROL&OCCUPANCY SENSOR SCHEDULE NOTES: z Q 1. PROVIDE ADDITIONAL POWER PACKS;SENSOR SWITCH PP20 AS NEED FOR QTY OF OCCUPANCY SENSORS/SWITCHES. J � 2. DEVICE COLOR SHALL MATCH WIRING DEVICES;REFER TO SPECIFICATIONS. F 9 AREA B- LIGHTING PLAN ® 3. REFER TO MANUFACTURER DOCUMENTATION FOR QTY AND SIZE OF CONDUCTORS BETWEEN LOW VOLTAGE SWITCH,SENSOR(S)AND POWER/RELAY PACKS. O J 4. PROVIDE SECONDARY RELAY PACK;SENSOR SWITCH SP20 AS NEEDED TO PROVIDE DUAL-LEVEL SWITCHING OF FIXTURES. LL- SCALE:1/4"=1'-0" 0" 4' 8' 5. PROVIDE 0-10V DIMMING CONDUCTORS(GRAY&VIOLET)BETWEEN SWITCH AND LIGHT FIXTURES FOR DIMMING CONTROL. z o U NORTH 0 5 GENERAL LIGHTING CONTROL NOTES: LL U z E.C.SHALL BE RESPONSIBLE FOR THE PROGRAMMING/COMMISSIONING OF THE LIGHTING CONTROL SYSTEMS TO FUNCTION AS INDICATED ON THE DRAWINGS 22 W • AND SHALL IN ALL REQUIRED COST IN THE BASE BID.FOR AREAS WITH DAYLIGHTING CONTROL,THE DAYLIGHTING SET-POINTS SHALL BE COORDINATED N F�J WITH THE OWNER FOR EACH AREA PRIOR TO FINAL PROGRAMMING OF THE DAYLIGHTING SENSOR(S).ALL PROGRAMMING/COMMISSIONING SHALL BE DONE BY z > LU A FACTORY CERTIFIED OR TRAINED PERSON. cc LU m • LIGHTING IS SPACES WITH WIRELESS CONTROLS SHALL BE FIELD TUNED TO FOOTCANDLE LEVELS THAT ARE SATISFACTORY TO THE OWNER DURING LU LU w CO PROGRAMMING AND COMMISSIONING OF THE WIRELESS CONTROL SYSTEM. 0 Cc Q o � LU G w LU Q LLI Q r PANEL:A2 PAYNE ENGINEERING 'AT LOCATION: VOLTAGE:120/208 Wye A.I.C.RATING:(E) PROJECT: FED FROM:A PHASES:3 PANEL TYPE:MLO E-STREET MOUNTING:SURFACE WIRES:4 PANEL AMPS:100A ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:N/A MFG&MODEL:SIEMENS/LOADCENTER DIMENSIONS:20"W x 5.8"D x"H FEED:(E) NOTES: EXISTING PANEL a r � I I 0 WORK ��v♦♦ NTHIS I T T__T__T_T_____T_____T_____T_T__T__T AREA � I I I I I I I I I �� 11 CKT CIRCUIT DESCRIPTION NOTEI AMPS' P A B C P 'AMPS'NOTE' CIRCUIT DESCRIPTION CKT' •,..+ +__+__+ __+_____}_+__+__+________________t__1 o F-3 JI(E)Treadmill 20A 2 F-0-1-0-+-p T-Q 2 20A i(E)Treadmill F_2_ 5 (E)Treadmill -- 20 A 1 0 O i I I I 6 C� .rn r� I az-s ( ) ra o J _I 2 I20 A I (E)Treadmill F-a A.RR _I \ __T__� +__+________________+__i �w 6 U- 9 Receptacle N 20 A 1 900 0 10 F__ +__+_� F__J___+__T___ 2 20A :(E)Treadmill F__i .q 11 Receptacle N 20 A 1 360 1 0 12 1-i 3 /- F13+Receptacle-----------+-N +20A+1+540T0� F-- +1+20At-- t(E)N +141 �j ,5 + _ - i KEY PLAN EF-1 2 F__+_ ___________+__+__+_ _______________ V N ° A2-9 F---I OVEN N 40 A 2 1-- -- 2 20 A -- E Treadmill V LF) AC 17 F-- +a000� o-I IO pis i w .. F--1----------------`- ---OAD:+-----+-----+-- +-1--1--1---------------- FBI '�I A2-13 t TOTAL L 0.5 kVA 4.9 kVA 4.4 kVA >O +_____+_____� I A2-15,17 I TOTAL AMPS: S A OWORK p, a BREAK RM #8's TOTAL ESTIMATED DEMAND AMPS: 23 A U Ca INTHI ________L_________________________—__ F----------------------------- cG CC AREA NO WORK BRA NOTES: •rl cn IN THI A=ARC-FAULT BREAKER GP=GFEPD BREAKER N-NEW CIRCUIT BREAKER SIZE/TYPE AS INDICATED m REA CR IS=SHUNT-TRIP BREAKER G=GFCI BREAKER R=RED HANDLED,LOCKOUT TYPE A2-11 I..� AC r A2-13 I J ACt -I-AGA2-11 I AREA AREA 19 AREA B— POWER/DATA PLAN CITY APPROVED PLANS DATE: 12/4/23 U SCALE:1/4"=T-0" 0" B. ® Reviewed for Code Compliance SAM TEP NORTH 5 'v Dr #23047 cnwkEa S�ONAIF PROJECT#:23118 PLANS MUST BE ON JOB SITE F0 tSTE �i4 PSG �� �PAYNE PROJECT p FOR ALL INSPECTIONS 13053 Engi�Pring Inc. 12/4/23 1823 E.Center E1 .2 SHTq/F OF t�p�OQ eoD208 232 4439 atello,Idaho 201 qk'N A.MEND —payneengineeringinc.com Page 27 of 29 O KEY NOTES: 1 E.C.SHALL PROVIDE AND INSTALL NEW 200A FUSED ENTRANCE BUCKET IN EXISTING SWITCHBOARD IF POSSIBLE. CONDUIT(S) OTHERWISE CONTRACTOR SHALL VERIFY WITH LOCAL AHJ AND TAP EXISTING BUSS TO FEED NEW 200A DISC.IF ACCEPTED BY LOCAL AHJ.THE FUSED DISC.IS NOT REQUIRED IF A FUSED BUCKET IS UTILIZED WITHIN RECEPTACLE-20AMP SWITCHBOARD. RATED-SEE SPECIFICATIONS. ROOF NORMAL POWER COLOR-(SEE SPECS) 4"SQUARE - BOX 2"C.,4#3/0+1#6G COVER PLATE-STYLE&COLOR TO BE AS PER SPECIFICATIONS. CIRCUIT NUMBER TO BE WRITTEN ON RAISED RING ®® BACK OF COVER W/FELT-TIP MARKER PANEI TO SUIT WALL K O 9 GREEN INSULATED MAIN LEVEL GROUND CONDUCTOR A RECEPTACLE MOUNTING DETAIL EXISTING SQ.D SCALE:NONE o TYPE QMB SWITCHBOARD 600A MAIN FUSE, 208Y/120V,3P,4W T T T T r +----- o 0 0 F_S�J__Ski CONDUIT RIGIDLY SUPPORTED TO NEW 200A/3P FUSED PREVENT MOVEMENT _ __ _ __ DISC.SWITCH W/ 200A FUSES,MOUNT OUTLET BOX WITH TWIST-LOCK J ON END OF SWITCHBOARD RECEPTACLE NEMA L5-20R r---------� Q r---- 7 i CEILING W L_________J__ TWIST-LOCK PLUG 06 06 i i � NEMA L5-20P -- T (n Lu 2"C.,4#3/0+196G J KELLEM GRIPS r -T ------r i (SIZE AS REQUIRED) O Lu BASEMENT LL o Z TYPE 12/2 WITH GROUND O u) SOCORD �z u n PARTIAL POWER RISER DIAGRAM N w r KELLEM GRIPS SCALE:NONE (SIZE AS REQUIRED) z LU OUTLET BOX WITH(2)DUPLEX LU W = GFCI RECEPTACLES. Q W m w 0 S � � O r Q Lu a COORDINATE PANEL:K PAYNE ENGINEERING PANEL:B PAYNE ENGINEERING HEOWN WITH LOCATION:(E)OFFICE 19 VOLTAGE:120/208 Wye A.I.C.RATING:101, PROJECT: LOCATION:OFFICE 25 VOLTAGE:120/208 Wye A.I.C.RATING:(E) PROJECT: WORK SURFACE FED FROM: PHASES:3 PANEL TYPE:MLO E-STREET FED FROM: PHASES:3 PANEL TYPE:MLO E-STREET MOUNTING:SURFACE WIRES:4 PANEL AMPS:225A MOUNTING:SURFACE WIRES:4 PANEL AMPS:225A ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:N/A ENCLOSURE:NEMA 1 BUSSING:SEE SPEC'S MBR AMPS:N/A A, MFG/MODEL:SO.D/NA1 B DIMENSIONS:20"W x 5.8"D x'"H FEED:TOP MFG&MODEL:SO.D/NA1 B DIMENSIONS:20"W x 5.8"D x"'H FEED:(E) 4/ NOTES: NOTES: �..� EXISTING PANEL,UTILIZE TANDEM-BREAKERS IS NEEDED FOR NEW CIRCUITS. r r-- --T-- - ----- ----- ----- - -- -- � U T T T T T T T T-- CKT CIRCUIT DESCRIPTION NOTE AMPS P A B C P AMPS NOTE CIRCUIT DESCRIPTION CKT CKT CIRCUIT DESCRIPTION NOT AMPS' P A B__+ + C P AMPS' + NOTE' CIRCUIT DESCRIPTION CKT' c F--+----------------+__+__+_+--T--+__- __-_ + + +_______ --1 M 1 Kitchen Equipment 20 A 1 384 1200 1 20 A Cooler/Freezer Ltg 2 1 (E)EXISTING -- 20 A 1 0 0 2 •t") m __+20A+1+__�__+-0T-0 2 20A __ i(E)EXISTING F 4 rl co 3 Kitchen Equipment 20 A 1 384 540 1 20 A Receptacle 4 3 (E)EXISTING �I o + +_� +__T__+_+__+__+________________+__� 5 Kitchen Equipment 20 A 1 640 360 1 20 A Receptacle 6 5 (E)EXISTING -- 20 A 1 0 1 0 i 6 U 7 SPARE -- 20 A 1 0 540 1 20 A Receptacle 8 F 7 +(E)EXISTING + -- +20 A+1+-0 �_0_ F-- 2 20 A -- i(E)EXISTING F-8 { �I b o 9 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 10 F 9 +(E)EXISTING + -- +20 A+1+-- +-0 T-0 F 1+20 At -- +(E)EXISTING +10 11 SPARE -- 20A 1 0 0 1 20A -- SPARE 12 F 11 +(E)EXISTING ---------+ -- +20A+1 F-- --+-0 T-0 +1+20A+ -- +(E)EXISTING ---------+12 i 13 SPARE -- 20 A 1 0 0 1 20 A -- SPARE 14 13 0 0 1 20 A -- (E)EXISTING 14 ^ F--;(E)EXISTING -- 20A; 2 [-- --+--T--] �_+--+--+----------------+--� KITCHEN CORD DROP DETAIL 1-4k�l 15 SPARE -- 20A 1 0 0 1 20A -- SPARE 16 F15+----------------t 0 0 1 20A -- (E)EXISTING 16 °O 17 SPARE 20 A 1 0 0 1 20 A SPARE 18 17 (E)EXISTING -- 20 A 1 0 1 0 18 U SCALE:NONE +__+__+_+__T__� F__ 2 20A -- i(E)EXISTING �j 19 1739 171 20 19 (E)EXISTING -- 20 A 1 0 0 20 HVAC HP-1 25A 2 2 20A HVAC FC'S F--}________________+__+__+-+__L__+__T__� r_+__+__+________________+__i +�.r W Z 21 1739 171 22 21 (E)EXISTING -- 20 A 1 0 1 0 1 20 A -- (E)EXISTING 22 „y 9 O + + +_� F__ +__T__+-+__+__+________________+__i 23 1739 0 1 20 A SPARE 24 23 (E)EXISTING -- 20 A 1 0 0 1 20 A -- (E)EXISTING 24 HVAC HP-2 25A 2 +__+_+__T__� F__J___+_+__+__+________________+__i U Q a 25 1739 2250 26 25 (E)EXISTING -- 20 A 1 0 0 1 20 A -- (E)EXISTING 26 2 30A Water Heater F--}----------------+---20 +-+--1--+--T--� F-+--+--+----------------+--i 04 1 27 2563 2250 28 27 (E)EXISTING -- 20 A 1 0 0 1 20 A -- (E)EXISTING 28 'r'I M HVAC HP-3 35A 2 F__+________________+__+__+1d F__L__+__T__+_+__+__+________________+__i P- 29 2563 240 1 20 A Cooler Evap.Unit 30 29 (E)EXISTING -- 20 A 1 0 1 0 1 20 A -- (E)EXISTING 30 m F--+----------------+--+--+-+--T--� F-- +-+--+--+----------------+--i 40 31 7445 ,248 32 31 (E)EXISTING -- 20 A 1 0 0 , 20 A -- (E)EXISTING 32 2 15A Cooler Cond. } + + +_+ +__T__� F._+__+__+ __________+__i 33 Item#14 80 A 3 7445 1248 34 33 (E)EXISTING -- 20 A 1 0 0 1 20 A -- (E)EXISTING 34 35 7445 832 36 35 (E)EXISTING -- 20 A 1 0 0 1 20 A -- (E)EXISTING 36 2 20A Freezer Evap.Unit F __________+__+__+_+__T__� __+ +________________+__i 37 7445 832 38 37 (E)EXISTING -- 20 A 1 0 1 0 1 20 A -- (E)EXISTING 38 _ +_+ +__T__� �_+__}__}________________+__i 39 Item#14 80 A 3 7445 2704 40 39 2500 2500 40 41 7445 2704 2 35 A Freezer Cond. 42 F 41 j Electric Clothes Dryer 30 A 2 F--1--+2500T2500 2 30 A N Electric Clothes Dryer F 42{ t____________ +__+__+_+__T__I F__ __+_+__+__+________________+__� TOTAL LOAD: 25.0 kVA 26.5 kVA 24.2 kVA 43 Washer N 20 A 1 180 180 1 20 A N Washer 44 F--+----------------+--+--+-+--1--+--T--� F-+--+--+---------------..44 TOTAL AMPS: 209 A 222 A 201 A 45 (E)EXISTING -- 20 A 1 0 0 1 20 A -- (E)EXISTING 46 PANEL LOAD SUMMARY 47 Receptacle N 20A , 720 1000 20A N Elec Heating 48 49 Receptacle N 20 A 1 720 864 1 15 A .VAC ERV-1 50 F--+----------------+ N +0 +-+--1--+--T--� F-+--+--+----------------+--i 51 Receptacle N 20 A 1 720 0 1 20 A -- (E)EXISTING 52 LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR EST.DEMAND PANEL TOTALS F--}----------------+--+0 +I F--1--+--T--+-+--+--+----------------+--{ E ui ment 1200 VA 100.00% 1200 VA 53 iReceptacle L N J 20 A L 1 770 11000 1 120 Ay N,R 1FACP/Fire Bell 1 54 +_____+_____+__ +_ _________ i DATE: 12/4/23 HVAC 12422 VA 100.00% 12422 VA TOTAL CONN.LOAD:75650 VA TOTAL LOAD: 1.9 kVA 5.7 kVA 8.5 kVA F _+ � Kitchen E ui ment-Non-Dwellin Unit 56088 VA 65.00'/e 36457 VA TOTAL EST.DEMAND:56019 VA TOTAL AMPS: 16 A 53 A 76 A CITY APPROVED PLANS SAM TEP Receptacle 1440 VA 100.00% 1440 VA TOTAL CONN.AMPS.:210 ATOTALF------ Dr— cxa<e�a P _ __ ____ ESTIMATEDDEMAND AMPS:_________45_A_____ _i _ TONAL PROJECT#:23118 Elec.Heating 4500 VA 100.00% 4500 VA TOTAL EST.DEMAND AMPS:155 A FBRK NOTES: Reviewed for Code Compliance F'SSr STEP v07't' #23047 BRK NOTES: A=ARC-FAULT BREAKER GP=GFEPD BREAKER N-NEW CIRCUIT BREAKER SIZE/TVPE AS INDICATED FP0 HF 4` P—ECTx A=ARC-FAULT BREAKER GP=GFEPD BREAKER LCP=CRKT TO BE ROUTED THROUGH LTG CONTROL PANEL S=SHUNT-TRIP BREAKER G=GFCI BREAKER R=RED HANDLED,LOCKOUT TYPE PLANS MUST BE ON JOB SITE PAYNE L ___ ____________________-__J En ineerin Inc. S=SHUNT-TRIP BREAKER G=GFCI BREAKER R=RED HANDLED,LOCK-OUT TYPE FOR ALL INSPECTIONS �130530 9 9 E21.� 12/4/23 1823 E.Center J' )Tq OF\D .1c(208 2 2-44 93201 qk'N A.MEND www.payneengineeringinc.com Page 28 of 29 . r ore staurant Desigri Fy cjuppl es 0 11 0 0 0 0 0 0 www.bsrequiPment.00 a Twin Falls,ID O 198 Locust St.. S.S. O O O O Phone(208) 733-4221 Boise, ID 09 8648 iWE 7 l aSt. ® Phone (208) 345-5793 Idaho Falls,ID 83401 925 Turnbull Dr. O Phone (208) 528-6233 OFFICE OFFICE o 14 < -7 Q/ �1 13 7 W\ "s 8 11 10 8 IT I +-+ 3 12 ^ _0 _ W 5 3 3 EQUIPMENT SCHEDULE ELECTRICAL PLUMBING Item No Quantity Category Voltage Phase Amps NEMA Cold Water(in) Hot Water(in) Indirect Waste Size Gas Size(in) Gas MBTU Equipment Remarks Unit Special z 1 1 WALKIN COMBO ea q 2 1 Mop Sink 112" 1/2" ea F- 4 Post as Q U 3 1 One(1)Compartment Sink ea O 1 Wall/ Plash Mount Faucet ,;2" „2" ea CITY APPROVED PLANS 1 Faucet,,Parts&Accessories ea 66 � 4 1 Three(3)Compartment Sink ea LU ' ea z 1 Pre-Rinse Faucet Assembly 1/2" 1!2" ea Reviewedfor Code Compliance 0o 1. 1 Add On Faucet,for Pre Rinse Faucet 3/8" ea 0 1 Faucet,Parts&Accessories as PLANS MUST BE ON JOB SITE ^ 5 1 Work Table,72",Stt ainless Steel Top ea PRINT DATE: 1 Casters st 6 1 Work Table,72",Stainless Steel Top ea # 1 Casters st 7 5 Wire Shelving ea FOR ALL INSPECTIONS 4 Post ea DRAWN BY: 8 1 Hand Sink 1/2" 112" as # 9 1 Ice Maker with Bin,Cube-Style 115 1 7 5-15P 3/8" 112" ea 1 Water Filtration System,for Ice Machines ea 10 1 Work Table,72",Stainless Steel Top as SCALE: @ 11X17 2 Work Table Drawer as 1/4"= 1' 11 1 Work Table,72",Stainless Steel Top ea 2 Work Table Drawer as 12 1 PASS-THRU SHELF as SHEET NUMBER: 13 1 Refrigerated Merchandiser 115 1 1 3.2 5-15P I ea 14 1 Combi Oven,Electric 208/240 3 62.2/53.9 3/4"GHT 2" ea 1 208/240 3 62.2/53.9 3/4"GHT 2" ea 2 3/4"GHT ea 1 1 120 1 1.6 5-15P as 15 1 Proofer Cabinet,Mobile 120 1 ea 16 1 Grease Interceptor as DRAWINGS APPROVED BY: XDin ri es 0 L29 OF: #