Loading...
HomeMy WebLinkAbout01-664 851 Pole Line Rd plans o �� 5� A Ir.1 v W LLin U2V u•• ii Uce Z •Ua O Q W New w O mam PRIORITY ITEM NOTE: REVISIONS CONSTRUCTION MANAGER AND UTILTIIES CONTRACTOR SHALL COORDINATE WITH OWEST _ oAq� RECEIVE 0 COMMUNICATIONS REGARDING SPECIFICATIONS OF TRENCH FROM SITE TO BUILDING. j e NOV 0 5 2001 I O I I 0jTy OF TWIN FALLS % i $ BUILDING DEPT. j knL__ i I _ i iI III \ i I \ e ADJACENT SHOPS ELL COMPUTER CORPORATION n BUILDING TECHNICAL SUPPORT CENTER \\ 1 49,126 S.F, i 6 4" 23' 10 43Lej c`—n M M I i 0� I�•ry ..........-.......-......-.............,* I °�(n I ff W oM DELL COMPUTER j �' Ui o \I I P � V Y. i v aLL J� 1 CORPORATION � c,' o0 I ' N M TECHNICAL SUPPORT CENTER - - - - - - - - I x LU Cc FIRE DEPARTMENT LOGKBOX oQ NEXT TO ENTRY DOOR LO O C 851 POLELINE ROAD WITHIN PROPERTY LINES,REPAINT PARKING r ��r/// LOT STRIPING COLOR PMS 0300 (BLUE) ® ® j c/^ �/) ) OVER EXISTING YELLOW STRIPING. TWIN FALLS, IDAHO COORDINATE WITH CONSTRUCTION MANAGER. U LT.., 22'-4" 16'-I" 43'-101/I6' 6"\43 t3' 16' I" 4 -11.. 16' 1"\43-9' 15'-10 I / / 4 Uj w / u.w i pQ U — —— — _.._.._.._.._.._.._.._.._.._.._.._.t_.._.. Z _.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.. — w O LU � I-�•, cry U CTA ARCHITECTS ENGINEERS SITE PLAN �-. LU 1185 GROVE STREET. RNOV 0 5 2001D W ~ NORTH p BOISE, IDAHO 83702 °'TM�NGDEPT. U BUILDING DEPT. BOISE•GREAT FALLS cj p N BILLINGS•MISSOULA HELENA • MISPELL I� a � wnr j VICINITY PLAN CONTACTS DRAWING INDEX Q 00 U I:I tist�a }� f. ARCHITECT/ ENGINEER CONSTRUCTION 1"fANACzER GENERAL 1"(ECHANICAL _ i r3.'! {111, ROBERT BEER Gla COVER PAGEMlml HV4C LEGEND SCHEDULE,9PECIFICdTION9 J� GT4 ARCHITECTS ENGINEERS 97dR CORPORATION 30 , 6cc� ,€ � ` \b'i. IBO19F D 8310ISS GROVE REET P.O.BOX 46 M201 HVAC DEMOLITION PLAN � a� ''� ,{4, t1"� TWIN C FALLS,IDAHO 83303 PHONE 208.336.4900 M301 HV4C REMODEL PLAN r` .... \, > I PHONE208-133-1224 1 )., }3 k ;,y �` FAX•208.343.3531 FAX,208-134-9531 ,,� `�`'�+�, ARCHITECTURE ARCHITECTURAL ""oF P /'' IiT l t�,�. ¢+'fr'f\ BRIAN HAUFFCHITS A001 DEMOLITION PLAN CTA �OJEC I �,;,< %u h CTA ARCHITECTS ENGINEERS AP212 9Ld5 PLAN CHTECTS { ?SITE . `, DRI4NHfCTAGRouP,COM ELECTRICAL , • aD3 = 4101 FLOOR PLAN —`� r� AI02 MEZZANINE,ENLARGED FIRE/CODE PLANE EI01 ELECTRICAL SPECIFICATIONS LEGEND AND SCHEDULES N 4 A103 ROOF PLAN EI02 ELECTRICAL POWER RISER DIAGRAM AND DETAILS c ti L i x �,; STRUCTURAL ENGINEERING E103 PANEL SCHEDULER °sI, f )I Pole rn w� �• _ BHAWN REEDER,PE A201 EXTERIOR ELEV4TION9)W4LL SECTION � f CTA ARCHITECTS ENGINEERS E201 LIGHTING PLAN NT ti 1. w�Y A301 DETAILS E202 LKsHTING P G LAN (MEZZANINE) s '83 I� '.� ti A302 STRUCTURAL NOTES AND DETAILS V E301 POWER PLAN _?"i7 r, - MECHANICAL ENGINEERINGENGINEERINGA50I ROOM FINISH PLAN E302 POWER PLAN?MEZZANINE) J TOM DIETRICH m ? OB 7 C J A60I DOOR 4 WINDOW SCHEDULE 4 DETAILS E401 SPECIAL SYSTEMS PLAN lu f ;'. ,C �S �� f r LTA ARCHITECTS ENGINEERS Ed02 SPECIAL SYSTEMS PLAN(MEZZANINE) C Filet Ave S - ASOI REFLECTED CEILING PLAN DEL Esm ELECTRICAL DEMOLTION PLAN f PLUMBING {p lF?Qfs r _ av d IIS W .� •� J""-'-,_j' WN CHEC t� I TOM DIETRICH '• f) !.l l}C { 1`, (( A`' I I 1 CTA ARCHITECTS ENGINEERS PLUMBING Jr Building Plans ATE ,x 1t. I, i _ P101 PLUMBING LEGEND,SCHEDULE AND SPECIFICATIONS Par • 'VBu4( ELECTRICAL ENGINEERING REVIEWED 50 P201 DWV DEMOLITION AND REMODEL PLANS For Co nformanca With SCOTT WILSON Uniform Build: SHEET �'- P301 WATER AND GAS DEMOLITION AND REMODEL PLANS ng Code CT 4 4RCHITECTB ENGINEERS All ConStruCtlOn } — Irnber Subject tO Field lns pection COV E [_ r l7rcFtar 0 4rcha"d r FIRE PROTECT ION PAGE 'I. ) U, G I ' 1 1 r•-,- FP-0 FIRE PROTECTION PLAN 74 j �.n '1 �` 1 �` SHE • —� Q}y I' NORTH -_ _ - 4 r O ri `t a f� — •�.r._ -�- REF. 01 QY Q �/ O 10 1 1 12 13 14 KEY Ln s EXISTING WALL CONSTRUCTION N TO BE REMOVED = IQ-W L �2Z 500 - - -_-_-.--- -----0 a �Z *6� i I I W yZJ I i j j I 22 32 j t8 U ¢ mmx 1 jj i I 311 I r==--=------------ 0 REVISIONS i i I i i 32 I i DEMOLITION PLAN KEYNOTES I. REMOVE EXISTING DOOR FRAME,END RELATED ITEMS, 2, REMOVE EXISTING WINDOW,FRAME END SLATED ITEMS 3. REMOVE EXISTING CASEWORK AND RELATED ITEMS, 34 4. REMOVE EXISTING INTERIOR WALL AND ALL ITS ASSOCIATED COMPONENTS. rr 4 5, REMOVE GYP,BD.FROM THIS SIDE OF WALL ONLY, 6. REMOVE EXISTING WALL COVERING ON GYP.BD,TO 410'-0', r PREP GYP.BD.TO RECEIVE NEW FINISH. - I I I - �I --- I ----------- - - - I -.ly__---_-- 8 1. DO NOT REMOVE EXISTING FLOOR COVERING,LEVEL FLOOR A8 REQUIRED. � 25 25 f 36 1-1 --�--_-----�-------------_i___•---_-----• 'I --� PREP FLOOR TO RECEIVE NEW FLOOR COVERING.RE:d501 i 1 1 r I _ I ) 1 1 S. REMOVE EXISTING STAINLESS TEE X S NG S NL SB STEEL COLUMN WRAP PREP COLUMN . ________________ _.,________ _-________ = e_ �- TO RECEIVE NEW PAINT.RE:A501. � II'�� { , i ��I '© I, f__ I II I I 11 .• J____1____! LC__L_ L___L___L_ I' I ,+, ,I I I' I' \^� .a --111 ' ,I 9. REMOVE EXISTING CONCRETE CURB FLUSH W/ADJACENT CONC.FLOOR SI----- - I 1 1 I 1 W I r r I I II g'�' ly I I �I q n_ 1 SLAB.PATCH AND REPAIR SLAB AS RSQ'D,PREP FLOOR SLAB TO r' 1 L I II ```� I r' ' - + RECEIVE NEW.FINISH.RE:A501, - ---- - g. ' Sf--i----i----� �---�-- i 1 �� i 1'� 'I U .4'' YI 4' ----I- 4 -,---'-- r 1 4 -�I' ''-' !I ``. .'' I I ; 11 a o'Y ., __II ; rl I I 1 I0. REMOVE EXISTING CONCRETE SLAB,PREP AREA TO RECEIVE NEW _I I 1 __' ! I _ li I 1 m '-r' ,'i ,F 1 m. J I ,r , 'I a __i _4 1 ,'� II 4"CONC.FLOOR SLAB,RE:AI04 A501. _I____I f a =a== L I `•C "` I ,1 4 1 ;1 ``�` P Oj-I - I I _ _-L_tL=J 1.-__l-1 -.I 7" -ter IL REMOVEMODIFY EXISTING ACOUSTICAL CEILING GRID AND TILES AS NEEDED,SEE A90I. -i------------------ ,- 1 {I,l� _i LI___L___L_L_IL_�!, -''�' ==- 12, REMOVE EXISTING GYP.BD.CEILING ,.. '1 -- I_!_____-_______s..L_-: I•-.-._.',..G_.____-___J_�1-_-_-�_�.`-_ -_J - !_->�._-�' '-_-_ -_- -11-_-_-_u_�_---J_.-_-_-_-_-_-_�L-_-_-_-.-3'L_ i _,._ __ 11m_. __-.. ..__.. -_-_-_-_-_-.-.-_-_-O 13. REMOVE EXISTING CEILING FRAMING SYSTEM,INSULATIONAND CEILING. ' 1-`` 11 , A T--- -,-'-1--- -Ti •--r--1 ' ___�.. c� __ r T--- � _ ------------------- I - '! � ` - .I- 14, MOVE EXISTING EXTERIOR WALL BLOCK-OUT,PREP WALL TO RECEIVE Iq I .L. IL -�L. '-1-L---L- -'----'•---1-� .- , . ' '------------- -C =====__===='==_!_______===='J n q n N I[-y,_ -' 'I _ ______ NEW OR END FRAME.RE:AI01,A601. • ^.zzz^-zz�z^-+.aazzA '--------------- ----- -�'- -------------- ---'! I , - 1 �I 15. REMOVE EXISTING DOOR FRAME AND RELATED ITEMS.PATCH AND REPAIR 1 III A II U N r/ \I WALL 70 MATCH EXISTING_ 16. REMOVE EXISTING PLUMBING FIXTURE,CAP SUPPLY AND DRAIN. 'rrr- ---rr, 'rrll'r-' cn RE:PLUMBING. {/qP♦n` _L v ,,3_. Il REMOVE GYP.BDA-TALL FINISH,COMPLETE TO STUD WALL. REMOVE EXISTING FLOOR MOUNTED STEEL ANGLE,PATCH AND REPAIR I I I v}♦ e♦` ,- I 18. FLOOR TO RECEIVE NEW FLOOR FINISH,RE:A501, ♦ _�___ _ i9. REMOVE EXISTING COOLER/FREEZER AND RELATED ITEMS. REMOVE EXISTING EQUIPMENT. I 3 p o a ' I ! I ~'r ' ♦♦ \`� 21. REMOVE EXISTING FURNITURE. tq IF i+I MM I ! ! I I v T♦ s� 22, REMOVE EXISTING DOOR,PREP FRAME TO RECEIVE NEW DOOR AND O I I ♦° HARDWARE.PAINT FRAME,RE,A5O1 I I n I 23. REMOVE EXISTING DOOR CYLINDER PREP DOOR TO RECEIVE NEW CYLINDER. N O --- - - ------- I -_-_-____--------------------------------------------!--------•-_---- L---------------------_3•3-^-_.- --_ E 24.REMOVE EXISTING WALL AND RELATED ITEMS TO .10'-PJ'THE BOTTOM OF O- _-_-_-_-_-_-_-_-_� THE SOFFIT. Z co 25, REMOVE EXISTING PIPE BOLLARD.PATCH AND REPAIR FLOOR SLAB I AS REQ'D, <L 26, REMOVE EXISTING STOREFRONT DOOR,PREP FRAME TO RECEIVE NEW GLASS,MATCH EXISTING.RE,A601, O i I I j 21, REMOVE EXISTING AUTOMATIC DOOR OPENING EQUIPMENT AND RELATED ITEMS. W`���7h••• 4 I I I 28.REMOVE EXISTING STOREFRONT DOOR PREP FRAME TO RECEIVE NEW �r�/ O ae ly STOREFRONT DOOR w N^ I 29.REMOVE EXISTING CEILING GRID,TILE,LIGHT FIXTURES AND RELATED ITEMS. O x W W I I I I RE:A901. >N I j j 30.REMOVE EXISTING SOFFIT,LIGHT FIXTURES AND RELATED ITEMS.RMA901. Ce W i K 31. REMOVE EXISTING DOOR CART WARDS.PATCH END REPAIR EXISTING ^ f 1 V Z FLOOR SLAB,PREP FLOOR SLAB TO RECEIVE NEW FINISH,RE:d501, w II�1) Lo Q I I WH co 32. REMOVE EXISTING CHAINLINK FENCE AND POSTS.PATCH AND REPAIR 1 d FLOOR SLAB AS REQ'D,PREP FLOOR SLAB TO RECEIVE NEW FINISH,RE:d501, I I I I I 33, REMOVE EXISTING CANTILEVERED ORNAMENTATION ABOVE.PATCH AND REPAIR WALL, vJ vl i I I j 34. PATCH AND REPAIR CONC.FLOOR SLAB.PREP FLOOR SLAB TO RECEIVE NEW FLOOR FINISH.NG CEIL ! ( ! I 501. 35. REMOVE EXISTING CEILING FAN. I ! ! 36. REMOVE PORTION OF EXISTING WALL.PREP.WALL TO RECEIVE NEW DOOR, RE,AI01,d601, U I p I 31. DEMO EXISTING CONCRETE SLAB,PREP AREA TO RECEIVE NEW COLUMN 0:a 1 I 8 I I 8 AND FOOTING.RE:A102,A301.1, n�3S, REMOVE AND SALVAGE WATER CLOSET FOR NEW RESTROOMS OR DISPOSE OF WATER CLOSET!CONTRACTOR'S OPTION)SEE ALSO PLUM51ON DRAWINGS. F� I I I 39. REMOVE EXISTING WINDOW FRAME AND RELATED ITEMS UP TO 10'-0"A,F,F, I SEE A601 WINDOW TYPE S. V� I I I I I W I j I I I I L.L 1 I ! i W GENERAL DEMOLITION NOTES LJJ A.PRIOR R BIDDING,ALL TRADE CONTRACTORS SHALL VISIT THE FACILITY O Z I I , END THROUGHLY FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS. B.SCHEDULE DEMOLITION WORK WITH THE OWNER TO MINIMIZE I I I I DISRUPTION OF SERVICES AND PROVIDE FOR THE UNINTERRUPTED V I FUNCTIONING OF THE DEPARTMENT. I I I I C.THE CONTRACTOR SHALL PROVIDE ALL DEMOLITION INCIDENTAL TO OR REQUIRED FOR NEW AND RENOVATION CONSTRUCTION WHETHER OR NOT IT IS SPECIFICALLY NOTED,INCLUDING BUT NOT LIMITED TO ALL (�dl�..+ OTHER WORK THAT MIGHT REASONABLY BE REQUIRED TO BE REMOVED Lu IN PREPARATION FOR SPECIFIED FINISHES.DEMOLITION SHELL BE PERFORMED IN A MANNER THAT WILL NOT DAMAGE ANY SERVICES IY+1�'. V) I I ! I I I ttJDICATED TO REMAIN.SURFACES SHALL BE PATCHED IF NECESSARY I TO PROVIDE A SUITABLE SUB-STRATA FOR NEW FINISHES. I ! DR OTIEC ALL ITEMS SHOWN A8 "DASHED'. I I ; £PALLLLTSUPPL IEST ALL EFISTING TO ROM DUST AND DAMARGETURE,CASEWORK END F,DEBRIS SHALL BE PROMPTLY REMOVED FROM THE BUILDING AND ' THE SITE AND DISPOSED OF IN A LEGAL MANNER SURFACES IN THE CONSTRUCTION AREA SHALL BE MAINTAINED IN d BROOM CLEAN CONDITION AT THE END OF EACH WORK DAY, �rr r G.REMOVE EXISTING FINISHES AS NECESSARY IN ALL AREAS TO RECEIVE NEW FINISHES. ; L___-___�n�_' __ I I � , H.THE CONTRACTOR SHALL MAINTAIN END ADHERE TO ALL CURRENT W �VIiL LIFE-SAFETY AND INTERIM LIFE-SAFETY RULES AND REGULATIONS THROUGH OUT THE CONSTRUCTION OF THIS PROJECT. ( l r 1 I I LTHE CONTRACTOR WALL PATCH END/OR REPAIR ANY AND ALL i ---r---r---'r---r•�--r---r---I I , SURFACES DAMAGED OR REMOVED DURING DEMOLITION TO MATCH EXISTING: SURFACES UNLESS SURFACES ARE TO RECEIVE NEW I �--------- FINISHES OR UNLESS NOTED OTHERWISE.REFER TO STRUCTURAL,MECHANICAL,ELECTRICAL,AND PLUMBING /1 Q DRAWINGS.. w 1 1 I r I 4 I J.ALL BUILDING SERVICES,INCLUDING MECHANICAL,PLUMBING,AND ELECTRICAL,SHALL NOT BE DISRUPTED FOR ANY LENGTH OF TME, NO MATTER HOW MNIMAL,UNLESS SCHEDULED AND APPROVED �) BY THE CONSTRUCTION MANAGER AND THE OWNER 1 n K.CONTRACTOR TO INSTALL SHORING WALLS FOR ROOF FRAMING AS REQUIRED L1 J -, ry"'^'J-"pr 1 t^" DURING CONSTRUCTION.SEE STRUCTURAL DRAWINGS.L___r___ _r_ _r___Ir___r___r___n I t +yi' ^/'1 , 1j1r 1 1 II r 1 /I I S.�qa.>♦� °' 1 I 1 r d 1 L.6EE PLUMBING,MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL 00 v DEMOLITION REQUIREMENTS, --- r- ----- - -.-- 34 - h I g Q2� ?i4p3l - I �Y� I I j I 24 y.'3 _ u i�_�_i6 ' IOI ���`auOF I I �- H ,. q6 ip 31 j 8 i 8 I i i - -1- - - - --/- a^^y^P c7n ______ ____j �r L4L_L_L___' ARCHITECTS-___ _-_-_-_ _-_-_---_-_-_-_-_-_-_-_-_-_-_-.-_-_-_-_�_-_-_-_-_-_-_-_-_-_-. -_-_-_--- _-_-I_ _�_T_r_ _- -_-_-_-_-_/ AR-1803 26 i I _-_-_ _-_-_-_-_-_-_---_-_- 1 -O i OAVI:L-TURNEN ti _ 9�(1 5�� U 4 015TO' `, ` c! i 8 8 I g 2g 8 24 2 29 3 " Q Q� - - - - - - - - - - - - - - - - - - - - - - - - - - - O 8 2� ---- ----------- 11 II^b" _ 1--•� _-_-_-_-_-_-_-_-_-_ . 1 y 1 I 1 ��... rJ-,L-I_ -_- -_-_-.- -_-_- -___ _ I 1 1 rl 8 i I __ ___ _I CTA JOB NO. f }I� _____-_____ -_ ro 1-"=-............ -1----1----r--�-- -r- DE LGC -I- - 1 --- --i--I 4 4 I-J"r----H- '-I----r-- ��- --1'--1---1 ( I I 1 I 1 1 I � I I 1 I I 11 1 1 II I-I----1 ----+----I- ----------1---I 1 6 ^� / DRAWN CHECKED a I 29 I ■ II_Jy_.__y____I.___y____I____I____I__I__I__� 1 1 r r -_-_---_---_-_- - JJK BH LL 5 O DATE L - --- --- -----'----'-- --I I I I I I --------------------/NI\ i 1 + j i 23 O SHEET TITLE j j 26 26- j j - - --------------■ •----------------- - - - -■--------•-------■ •---------------------------------------------------------------------•-----•----------- ---------------------------------- PLANO O DE OL IT ON SHEET DEMOLITION PLAN 4 4001 H - .. NORTH n Q 04 10 t t t 2 1 3 t 4 SLAB PLAN KEYNOTES 0 I I I I I I I. NEW 4"CONCRETE SLAB W/13 x 13 D5 x 05 W.W.F IS REQUIRED I I WHERE NEW OR DEMOLITION WORK HAS OCCURRED RE:A001 I I I I 2. NEW 4"CONCRETE SLAB FLUSH WITH EXISTING SLAB W/13 x 13 O ' ...,....,'._......_...._..... .. .... _.-._..L.-,.. .... D5 x 05 W W.F.FOR PLUMBING.RE:PLUMBING V �NpN 3. CONTROL JOINT WS am ~ W ti I I i I I ! 4. ISOLATION JOINT AROUND NEW COLUMN FOUNDATION RE:AIOI = Z GRIND CONCRETE JOINT A N 4 POSSIBLE AFTER CURING, _ f Ind , V•• V 8 9 000 8 BLE CU NG V I — -_—_—_— -O 5. NEW 4"CONCRETE INTERIOR SLAB W/13 x 13 D5 x 05 W.W.F.SLOPE •N Q 9 DRAIN.DOWEL INTO EXISTING SLAB AT 2A"O.C.RE:PLUMBING.. O W =Z 'I--r—'I---4-- r' f —� p 6. REPAIR FLOOR AT REMOVAL OF PIPE BOLLARD.R'MA001. I I 8 PREP FLOOR SLAB TO RECEIVE NEW FLOORING RMA501, m m= I I I I I I 1, REPAIR FLOOR AT REMOVAL OF CONC.CURB FLUSH WITH ADJACENT FLOOR SLAB.RE:A001.PREP FLOOR SLAB TO RECEIVE I I I ! I I ! A I \ NEW FLOORING RE:A501. REVISIONS 8. REPAIR FLOOR AT REMOVAL OF STEEL ANGLE.RE,A001. I I I I I I 1 I I `J\Z') PREP FLOOR SLAB TO RECEIVE NEW FLOORING RE:A501. Q (` / 9 - S. REPAIR FLOOR AS REQUIRED..PREP FLOOR SLAB TO RECEIVE NEW FLOORING 12E:A501. ' I v I I 8 10. PATCH SLOPED FLOOR AREA WITH LEVELING COMPOUND FLUSH WITH ADJACTENT FLOOR SLAB PREP FLOOR SLAB TO RECEIVE i I i NEW FLOORING RE:A501. ....... .. I II. NEW FLOOR ORAN.SLOPE CONCRETE FLOOR SLAB TO DRAIN. . . j 2 2 7 t i J I RE.PLUMBING, Ii B i - - - - - - - - - - - - - --------------mot -� - - - - - --- ------ - - - - - - - - - - - - -0 - - - - I - - - - - - - - - I - - - - - - -j-.-._- - -_..-=- - J _ • 71, f :I' _N O I I I j I PLAN TE•t. °: SLAB NNO S I � I t • :�. I I •L. ' 1. oEFE ENCE A001AI IPL M NG AND ELE dL FOR dDDITIONAL INF •4 ':r T ET T I SLABS. I I W NO W SUBGRADE PRIOR O POURING S BS A 7 ALL CONCRETE F STRAIGHT LINES.SAW CUT CONCR T OR CLEA 9 R4 7 N S N •'• _fit• .t _ _—.—.—_—.—_—_ .gip:.'':• - - — T I•�' — SAWN CONTROL JOINTS HALL E MADE USING "EARLY ENTRY 8 B P' 1 0 WET CUT SYSTEM.FOLLOW MANUFACTURER'S RECOMMENDATIO NS ` ..;.. .•,.•.�,.•. .•. . __— _ — � LICITLY. : "I• • ; A. CONTRACTOR TO BE RESPONSIBLE FOR ALL BREAKOUT, BACKFILL!COMPACTION FOR ALL BUILDING TRADES IN EXISTING BUILDING AREA,ETC„ IN NEW CONSTRUCTION IS BY RESPECTIVE TRADES, 4 A I 2 I S. SLAB BREAKOUTS SHOWN ARE GENERALIZED, 2 i i 2 I I VERIFY EXACT AMOUNTS,SIZES,4 LOCATIONS REQUIRED.THIS Q IV I I • PLAN SHOWS THE SLAB WORK TO BE PERFORMED 4 DOES NOT RELIEVE THE CONTRACTOR FROM REQUIRED WORK i I I I �•:t AS SHOWN ON PLUMBING 4 ELECTRICAL DRAW- . j i INGS. I ! I 6, NEW SLABS SHOWN WITHIN THE EXISTING BUILDING AREA j I I j INDICATE EXISTING SLABS TO BE REMOVED.RE.A001. N T, INSTALL %"EXPANSION STRIPS WHERE NEW BLAB WORK ABUTS O M VERTICAL WALLS OR AS INDICATED ON DRAWINGS. M M I ! ! I I S. NEW FLOOR SLAB SHALL BE 4"CONC.W/13 x 13 DE,x 05 W.W,F, c pI I I OVER 4 MIL.VAPOR BARRIER OVER r'LEVELING SAND OVER W �' ! ! 4"COMPACTED GRAVEL,REMOVE EXISTING SLAB t BASE GRAVEL. M I I I I SCARIFY TO A DEPTH OF 6"I RECOMPACT TO SS%OF MAXIMUM W.i� j i DENSITY IN ACCORDANCE WITH AST M 155T,REQUIRED EXCAVATION —_—_ _—_—_—_—_—_—_—_—_—_—_—._.—.—_—_—_—_—_—_—_�_—_—_—_—_—_—_ .. —_—_—_— —_ _---_—_—_—_o-.—_—_—_—_—_—_—_—_—_—_—!_—_—_—_—_—_—_—. .—_—_—_—_—_—_—_____—_—_—.—_—_—_—_—_—_—_,,___ —_—_—_—.—_—_—_—/mil FILL TO BRING THE BUILDING PAD TO THE DESIGN RESPSUBECTIVE DE O N —`�J ELEVATION SHALL BE PROVIDED,REFERENCE RESPECTVE 2 I I SECTIONS IN PROJECT MANUAL, r7 m X I I S. DOWEL AND EPDXY A Y3 BAR X 17'•24"O.C.INTO EXISTING SLAB W/4"EMBED MIN.TO TIE NEW SLAB INTO EXISTING,A MIN.OF(2) I I I I DOWELS ARE REQUIRED FOR SMALLER PATCHES. O i I I I 10. PRESSURE WASH ALL EXTERIOR WALKS,RAMPS,STAIRS 4 LANDINGS, TRUCKWELL 1 LOADING DOCK AREAS. AT LOCATIONS IN WHICH CONTROL JOINTS HAVE BECOME UNEVEN RIND O LW G LEVEL TO ADJACENT ELEVATION PRIOR TO INSTALLATION OF NEW VCT, w N^ 12. ABANDON EXISTING REFRIGERATION LINES.CUT SMOOTH AND FLUSH O x WJ W i I I I j WITH FLOOR SLAB.GROUT SOLID. N 13. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION ON CONDUIT I I I I I STUBS IN THE FLOOR SLAB. i+l /1 U WA Z I I I I Yf--Il IA O I I 2 I I I- 4 co d I I r- j - --- -- i i ��• I I I V J �/�J I j I I I I I I i I j I I I I 2 - LT. j_ --------------------------------------------------------------!----------------------------------------------------- ---- ---•-•--------. Z I i i i i i LAC W L. 2 i 2 I ! W 2i i I Z i i i i O Q W i i I i i w N 2 ! I I a W O ce i 2 j I I I I 2 -- i j I I j ��• j 2 j I I I I I I I 2 1 2 I I I I I i °ter ' ...._...._..._.__.. _.--__...—___-- _— _ •�..a PRC HITECT S*—_—_—_—_ _—_—_---_—_—_—_—_—_—_—_—_—_—_—_—_—_—_ _ _ PR-1803 I'tLTU E R 6r 2 '2'sT sO�V • o,`- - j I •. 1•S fD ARC'�T�O�� a - - - -1 - - - - - - - - - y - - - - - F - - - - - • - - - - - - - - - - - j------------------------ - ----- ------ - - - - 011 - - - Ij Ij - - - V CTA JOB NO. ----_---------------------- ------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - . ------ --- - -------•------ DELLCC DRAWN CHECKED w \\\\\ ■ - - - _-- - - - - - - - - - - - - - - - - Ir•,�,rnm"T"+�'—' I -.___. .... ...... JJK BH -1— I! _�-- I -- a -'— -•----------- -� DATE V a SHEET TITLE x ---- - I FLOOR SLAB _ _ _ - ------ PLAN • I I I I _ SHEET FLOOR SLAB PLAN 4,002 NORTH I WALL LEGEND S cn s N i I I NO t� P� Q NOTE, I I ~ W WW VIDE 4' "WIDE BY W-0"HIGH ' - I' I PLYWOOD BACKING 9•18"4F,F EXISTING S"CMU WALL U It'Z IN DATA CENTER AT AREA SHOWN i i I U iII iII - iIi iIi iII / t-�rrmi!lniriir" !!/l./IIIL!.',ffl11T!!1lfI1I7TIrCll//lIIITXCII/lNtT1EIlR.. i 1lIIIll I. '�rrrinrri7!J!!U/(��ZI!/l/I/!I!!/Cl//J/.1/117 IllL(lZYl710r/.l!1lJJl7l1IZllrllllrlJl/' I - e �1"1 `, vV m0 wIJ=0 %L/! 06GTI!!7!L ! GYP.BD. W 0 GA.STEL STUDS I6O.C. Q ZO O V Q� E / RISER ® TYPE X GYP,BD. '• GYP.BID. 16 GA.STEEL STUDS 9 16"O.C.FLOOR TO DECK I I I I v fJs TYPE 'X'GYP.Be. . I I I I I 16'•b" 40'A" I -r 6'e. ry 1 u ® 6L•GYP.BD, REVISIONS VERIFY ENCLOSED 'I4I-I' .---- v s 7 METAL STUDS 6 IV O.C.•6"ABOVE CEILING I I I I I DOCK BREAK s�GYP.BD. 140 Room (I6 GA.STEEL STUDS 9 IS'O.C.FLOOR TO DECK I I i i J GYP.BD. �...... • 11 , O -. I CLOSET ® !/p°TYPE 'X'GYP.BD. 5 G 16 Gd.STEEL STUDS 9 IV O.C.FLOOR TO DECK }r. I TRAINING I -- I30-I� Z °�"TYPE 'X'GYP,BD. 1,lll�llnrrrr/mrrorrr/r11701!/III�lllZal IIIIZIII7IlllJlllllIl!!Il 0--m ll�l/!d///'Ol29, llOirll/r110//l/l-I ZllllllllTr.. M .yll q I ROOM i �"4'X8'PLYWOOD SHEETS MOUNTED 9 18" HUDDLE o I v lu O 4F,F,g INTERIOR SIDE OF ROOM InI — — — — — — — — — — — — — 138 -_-_-_RONFEREIJCL_-U�--.-/-_ ROOM !n 14 r T — B -_-. - --_ -. - --- -i- -_-.-_-_- -_- -- ---_-_- 138-I - - -- I --.-.- 135-_-_-_\II� - — ---- - - — -- — — - Q - - 1 O SYI"IBOL LEGEND u —'l J—"m' ° — J — ------- ' -- -- -- ------- 13,-f y C�NFERENCEI , I i TRAINING �,, y H�9LWd7 ..•!HUDDLEil T �� A3 I , 1 JdNITOR 1XXXXX ROOM NAME ROOM NUMBER I45 I } 4301 TYP. I 143 W ROOM d' T7P. II/+ I I C' 1 t32 ''� 235,_T10�_3:. II'-0" 19'-3" 11 a'2" VERIFY I 13 / I I DETAIL OR SECTION NUMBER F(D 0�L�• " I I I ROOM-E� d301 II I v I IT ; 129 1� ; X.X SHEET WHERE DRAWN --- — --------- --------- ----- --------=,.. —------- — — ----- — 1 • �" ,ay°� �� i- � ,36 � - ' _ - --i------- 1 ca cac1a�oh ca �------------------Q i 13b1\. I i .A I 134-I 7•,1 1 I m V V d 1 \" „// I CLOSET m 1 IZBHj XX BUILDING SECTION 1461 o- fi . I =:`' 1 5"'8/i" 3'-4- 1 i 13A MEN'S , I2S , —I 6 I I I tv i s 1 x DETAIL SECTION 26'•Ih/s" I'_4" 3'_z" 1,2" I'•q" 2g:_I" 9'-II" II'-0" 17.11" I'_a" 3'_2"1' •3•_z" 'I'_d" 25'-5�/." "D,'-8"t XX Q 1 I I 16 I I v •------- -- -------------- •i XX DETAIL CALLOUT d3® I I I FAX/COPY I $ n O M ELEVATION CALLOUT � �M I I I I 5'-by.. 3'•0"31-0"3'PJ'3'-0' 4'_I'/x" Al" O Q WINDOW TYPE I� 0 M T i i i i RE:A601 LLJ CO 106-2;i ►-7. Ln O I I I O ImI-I DOOR NUMBER / Q -.- -_-_-_-_-_-_-_-_-_-_-_-_-_-_- -_-_-_-_--�_-_-_-_-_-_ _-_-_-_-_-_-_-_-_-_-_-_-_--a-_-_-_-_-_-_-_-_-_-_-_-,-_- -_-_-_ _-_-_-_-_---_-_-.-.-.-_-.-_-_-_-_-.-_-.K:^. _-.-_-_-_-_-_-.- E RE:A601 F-•� m X I I I I a _ _ Ilb'" I I I 1 1 1 VERIF7 A102 M GENERAL NOTES �� I I I I ti t I. RE.A901 FOR REFLECTED CEILING PLAN. Q N 2. RE.A601 FOR DOOR SCHEDULE AND WINDOW TYPES. ►Y�r1 (. YJ I I I \ 3. RFA501 FOR ROOM FINISH PLAN. ^ Z I I a. ALL DOORS ARE LOCATED •4-PERPENDICULAR FROM w �� �Q ADJACENT WALL U.N.O. d ALL DIMENSIONS ARE FROM THE FACE OF STUD NOT I a OR CMU U.N.O. USED 8 NQI I `�0�• i i - 6. PROVIDE ACOUSTICAL BATT INSULATION 9 RESTROOM WALLS. 301 TYP. i ; i i y DIVISION 9 NOTES I 13 �4ta I 1 GYPSUM BOARD ASSEMBLIES 4 Ys 1 %"TYPE"X"GYPSUM BOARD AT RATED U I T PARTITION WALLS.(SEE FIRE PROTECTION , 4 w PLAN) TEAM 2: ROOM I Q;v s „ I 1 -1/e REGULAR GYPSUM BOARD,TYPICAL AT Z 125 bd v 1 , O ALL NONRATED WALLS. �+ FAX/COPY -. L-_-_-_ -_-_-_. --.-_-_---_-_-___-.-_-_---_;_-_-_-_ -r.-_-_-.-.-_-_-_-_- F %WATER RESISTANT GYPSUM BACKING 1 BOARD AT ALL WALLS WITH PLUMBING 1• b° ; FIXTURES. METAL STUD SPECIFICATIONS �W F`•�1 > I A 1 I �d• IDF 0 I I ♦ 350Sb2-33 9 16 O.C. I2a i tY2M1�----- -3'/j"20 GA.STEEL STUDS 0 1&O.C. �HUDDLE FOR WALLS LESS THEN IT'-1"WITH / 5 PEP LATERAL LOAD AND DEFLECTION OF LU 14 C �2M L/2d0. p301 5509S162-54 9 I@'O,C. 9'-10' •5'/G"IB G4 STEEL STUDS 9 Id'O.C. HUDDLE FOR WALLS GOING UP TO ROOF DECK O ROOM !OR MAXIMUM HEIGHT OF 28'•4"1 5 PSF LATERAL LOAD AND DEFLECTION OF L/240. i i 121-I j A20I 7 126� ACOUSTICAL PANEL CEILINGS N O LU L 25'-3" 9S'•I" 23'$" i(, Q 'HUDDLE -SOUNDS CONTROL,NRC TE,55 w� "\ . ROOM -1L CERTIFIED CEILING ATTENUATION m C 120 CLAS9:MIN.OF 35 I/1 I -FLAME 9PRED,0-25,CLASS A V I -LIGHT REFLECTANCE:,BO -EDGE DETAIL,SQUARE Q HUDDLE •THICKNESS:1/p' �--7r y C ROOII -SIZE:24"X48" F%1 I I I I dp \ 119 -SUSPENSION SYSTEM TYPE: �y LU EXPOSED TEE ' I OV'�E4N OFFICE I I 119i j i � i i 2� 118-1i DIVISION Im NOTES O W I I I 4501 ,.:/HUDDLE �\ ` _-_-.-_-.-.-_-_-_-_-_-_-_--1x-_-_-_-_-_-_-_-_-_-.-_-I-_-_ � / T `J OPERABLE PARTITIONS � ANIVI' "MODERNFOLD"BRAND MODEL 1933 O CONTINUOUSLY HINGED 14 48- NOMINAL WIDTH � ' � 48"MAX WIDTH PER PANEL MANUAL OPERATION VERIFYWALL WAVERED CONSTRUCTION OF TACKABLE FABRIC VERIFY �J 10b1" GYPSUM BOARD LO AlS C INVISIBLE HINGE ^ X - - I I I 3• ; � l 8TC RATING 91LB9 PER SQUARE FOOT (M�+, w OPERABLE FLOOR SEAL INCLUDED I I TEAM I I T 0 IROOM � PLAN KEYNOTES 0 Ilbl 1. SECURITY CAMERA LOCATION. „ •y 5 2-A I I I I f 2, BADGE READER. plO2 4501 I I I I TEAM M 3. EXIT ALARM (WHEN DOOR 19 OPEN). ROOr IN'3'•0"3,�, I E AA IN.�4 I 5 � IIb A. "MODERNFOLD'OPERABLE PARTITION WALL,RE:DIVISION 10 NOTES .�"`'OF'.,/,� QABOVE 53,II" / _� 10'-T' 26'-8" 8'-5' 42'-3" 110 13'-0' I'-4" 2'-I I'-d' 12'-8" O 5. dL IGN FACE OF STUD W/EXISTING SUSPENDED ,�A't O — —' CTA RIFY WALL/SOFFIT ABOVE,RE.A30, 90I, h ARCMTECTS / / -' - P / d • AR-11803 • - __ —_—_,_—_—_ ------ _—_---_—_—_—_—_—_—_—_—_ _—_—_—_—_—_—_—_—_—_ �_—_ - - , __ . I — — � - -_—— _—_—.-�.— —_— r —.—_—_—_— —_—_ —_—_—_—_—_—_— b. FACE OF GYP.BD.W/ADJ4CENT EXISTING II �1NT€RVIEW-- ------- ALIGN i_ - I o Q TUF R ROOM O B \ _ I I v } FACE OF GYP.BD. �- n yf((•�•d 102 1 un 7 1 x`� / I d301 I I TEdM IISj 2 of ,, ALIGN FACE OF STUD W/CENTERLINE OF -�,I�'Y QUSTtajy O 8'-9/G 15'i" ! �� ROOM JdNROR m VERIFY VE Y ' of F_ COLUMN. � I III �W r 5'-10' 115 hn n /102-I '•1�... ,: /_—_—_—_—.----------------- INTERVIEW �_ >-6— 8. ACCESS PANEL DOOR ABOVE.RE:A601,d901, RECEPTION — — — — — 105i — J �� -`rri H W �� O 9. NEW DOOR TO BE GUT INTO EXISTING CMU CTA •JQB NQ, I ROOM '^ 101 I n _-_ -.D µ I UY 113 I ''1' BLACKOUT.RE:A201. ' ----#------ -- i®3 --�.- -itr------------•-------------_------ ....---1R:�IEp' ---;1�- -��------------ 5------=--•---•------------i---•-- 7 OELLCC - - - - - - - - qq ,/10}I �I LL CONFERENCE I MEWS 7�LL 114-I i O r S Y at 101 F4 /COP7 ` 112 v :'1.0 S \ : \104-I r -^° 109 I _ O n 112H m ua ' DRAWN CHECKED RORV INTERVIEW ` N� Q 4 --- —=--_— -- -- — ---- ------------- JJK BH LL 104 a0 j TAIR STOR .....\ ,'� STAIR --- — — DATE r CVE 201H 1201 108 I^-I� Mlp nrr�rlljllTnJJll77.?7,�1 -'---- --�---' O- -- - w1 SHEET TITLE i i i I 42� FLOOR i i --�. — — i-------- — — — —�— - — — — — — -------------i-------------- —i------------- ------------------------------------------------------------------------..----------------------------- — — — PLAN - i I I I SHEET • i i I i A101 € FLOOR PLAN AIOI 1'_0" NORTH 2'-10" 5'-0" WALL LECzEND ❑ II -- lZ1ZZZZTlL EXISTING 8"CMU WALL O <O d D = ¢�W H- • O GYP,BD. V I"" Z K 20 GA.STEEL STUDS a 16"O.C. 22 U=Fj t) li 9 2 9 2 9 2 9 2 9 2 8 2 GYP,BD. a u Z •U Z Z TYPE X.GYP,BD. O W =Z 5�Z"I6 GA.STEEL STUDS S IV O.C.FLOOR TO DECK (,J Q O 14 14 TYPE 'X'GYP.BO. m _ 6 U.L. 2 3 WOMENS ,. 1• s: ® s GYP BD 129 8 _ S.z"METAL STUDS a I6"O,C,•6"ABOVE CEILING I s f'GYP,BD. REVISIONS P 8D O 0 1 III-g: Id 5Pz GYP, GA.STEEL STUDS 0 16'O,C,FLOOR TO DECK O 29-I O 2'-6" 2'H' 2'-6" 2'6" 2'-0" 'GYP.BD. _. ! II 11 l 13 11 3 ® s�'TYPE X'GYP.BD. i ,� 0 0 '203-4 O 1 - N 1 ,sp2T PE GYPBD�XSTEEL STUl ' DS al6''O.C,FLOOR TO DECK ❑ ry ry ry �'d X8'PLYWOOD SHEETS MOUNTED 9 15" O AF F,a INTERIOR SIDE OF ROOM 203-3'. U.L. 11 Ila STAIR ME22ANINE STAIR 3 II 11 1 13 11 3 SYMBOL LECzEND 201 203 202 12B-I 2-0 _2-6 2 6 2 6 III-g^ 4'-0" XXXXX ROOM NAME 17 12 12 _, Fx-x-xl ROOM NUMBER �9 - 10 MEZZANINE PLAN MEN. 6. 1 I i5 128 14 DETAIL OR SECTION IJUMBER AI02 SCALE:�e -I'-0" 2'-0" X,X SHEET WHERE DRAWN NORTH REF- . ® BUILDING SECTION 10 l0 • XX 4 % - DETAIL SECTION - XX XX DETAIL CALLOUT 1 7 ENLARGED PLAN AI02 SCALE: "•I'-0" � X , vt XX ELEVATION CALLOUT NORTH S REF, co N TOTAL LOCKERS O 16L 24L 16L 24L la WINDOW TYPE N ^U)RE:A601 w OMD e f T� �c1• F•�•�1 M TTTm CzENERAL NOTES cwN ...... I. SEE PLUMBING DRAWINGS FOR ADDITIONAL D]v INFORMATION. a w , TYPICAL MOUNTING HEIGHT/SIZE LEGEND FOR FIXTURES 2, SEE SHEET A501FOR ROOM FINISH L` m . 6 LOCKERS 4 LOCKERS 6 LOCKERS 4 LOCKERS 6 LOCKERS FIXTURE DIMtt MOUNTING HEIGHT INFORMATION. G J S 6519V 6369Y 6519V 6369V 6519V GRAB BAR A 6• TO CENTER FROM ADJACENT WALL 3. PROVIDE ACOUSTICAL BATT INSULATION AT RESTROOM WALLS GRAB BAR B AD- CENTERLINE TO CENTERLINE 4, PROVIDE WATER RESTANT GYP.SRO.AT RESTROOM WALLS [-, I- 24 LOCKERS WIDE �" 1W GRAB BAR C 6' TO CENTER FROM ADJACENT WALL GRAD BAR D 36• CENTERLINE TO CENTERLINE ��yy O I M- PAPER DISPENSER F 36' MA%CRAB BAR ECTOTOUTBIDEA50Vr F NIBH FLOOR MEZZANINE PLAN KEYNOTES O SEE DIVISION 10 NOTES PAPER DISPENSER G 19" MINIMUM I, P-1 BASE FIELD PAINT.MFR: SHERWIN-WILLIAMS(S W) I.L4 W00 KINK NMAX O RIM ABOVE FINISH FLOOR COLOR,TBD O M T 3 MIRROR J 40" TO BOTTOM ABOVE FINISH FLOOR FINISH, SATIN LATEX Q ' TOILET(ADO) K I IB' TO CENTER FROM ADJACENT WALL r �� COLOR:WIL Q Z 5 LOCKER LAYOUT rAl MIRROR L 1A' MINIMUM A.F.F. 2. PL-2 PLASTIC LAMINANT.COL WILSONART (� - u SINK M 9• MINIMUM TOE CLEARANCE 3. RE-LAMINATE EX18TN(s COUNTER TOPE IN OFFICE. J o A102 KINK N 7l• MINIMUM TO BOTTOM OF KINK I I Un O �q () Vj NORTH SINK 0 SINK P 6'"FROMIMUM FACCETO 150TTOM OF WALL APRON r, /// a REF. .......I w LOCKER LEGEND ���q tiN UPS RESTROOM PLAN KEYNOTES O }\ 4 OX p 142 TOILET FIXTURE I, COMBINATION PAPER TOWEL 0 N a 16 LOCKER MODEL 6519V)SEE NOTES. (� (� 7 \� D18PENBER/WASTE RECEPTACLE,BRADLEY W ®• �T''o ` HUDDLL MOUNTING SCHEDULE BRAOEX MODEL 7021. ` J uu > •TIER LOCKER MODEL 6369V)SEE NOTES. F /y\�,p-Q v ROOM ®EXIT DATA 3 ) s ® 0 O J"y� 138 CENTER A102 2. TOILET TISSUE DESPENSER BRADLEY BRADEX fin/ O L•LOCKER(S) ti� OQ� J� HUDDLL DOCK SED Idl BREAK MODEL 5234 DOUBLE ROLL TISSUE HOLDER Q� ROOM 140 ROOM SEE 3/AI02. 131 3, SOAP DISPENSER,BRADLEY BRADEX DELBID. MODEL Z 6562(VERTICAL)I ON EACH SIDE OF GYP. ROOM 136 {li' A_3 D EXIT ~, B .WALL. II ® A. EEA102,GRAB A 3/ �ADEX 800 SERIES MODEL 059,S +' TRAINING OCCUPANCY TRAINm ROOMING ROOM N6, ROOM 5• SANITARY NAPKIN 4181!16P084L UNIT,BRADLEY w 143 I35 I'll, p': 133 u ¢ CONFERENCE <) 6, SANITARY NAPKIN VENDOR 15RADLEY BRAOEX ROOM A-3 •l.�_3 - MODEL 401. . /y 1, MIRROR AD-HIGH MOUNTED JUST ABOVE Lu OCCUPANCY OCCI;IPANCY SPLASH BLOCK AT TOILET ROOMS(APPROX. GODE ANALYSIS: MOUNTING HEIGHT TO THE B W OTTOry OF THE `•.,n�• MIRROR IS 38'ABOVE FINISH FLOOR). rr�dA.�/� APPLICABLE CODE,1991 U.B.C. F F•�••:1 CONTINUOUS MIRROR ABOVE LAVATORIES O Z FAX/COPY CONSTRUCTION TYPE,III-N TOILET ROOMS 128 4129,BEE 3/AI02. O L ry 12l OCCUPANCY TYPE6,A-3,B w JANITOR ALLOWABLE AREA.02,WO SF,X94%)•(9,100X6W•11.826 OF 8, ADA COMPLIANT TOILET,SEE PLUMBING. ? 132 u �+ AREA MCREASES 28 LOCKERS TOTAL m IRE SPRINKLERS,2)SI E 'e6 20' (I53,211 50% S. TOILET,SEE PLUMBRJCs, U 6L 16L 6L TOTAL ALLOWABLE AREA:53,211 OF. • 10. URINAL,SEE PLUMBING, AREA OF BUILDMCx O W 4 5540 9F,INA FINER) II. LAVATORY FAUCET,BEE PLUMBINC, EXIT • 12. 'WILSONART"INTEGRATED SINK w d9,126 OF. 4 BU121/BU122ADA.WIFT B CODE ANALYSIS 3, FINISH SURFACE COUNTER TOWS E ASCI HEIGHT. R U FINISH SEE ACE FOR MOUNTING HEIGHT, 1✓-�] w CORNER FILLER PANEL OCCUPANT NUMBER OF NO.OF EXITS O��I '1^�` I�V ROOM 8Q FT LOAD FACTOR OCCUPANTS REQUIRED 14. TOILET PARTITIOµ SEE DIVISION 10 NOTES. Lu i LOCKER=&L I LOCKER OCCUPANCY-+ N T fu 00 8F, 100 8 I --6369V 6519V6369V 100 SF, I0015. URINAL SCREEµ BEE DNISION 10 NOTES,98 SF. 100 I I 8 LOCKERS WIDE\ SO spa 105 107.8 SF, 100 E I 106 29329.5 OF. 100 294 7 DIVISION 1m NOTES O W TEAM ✓ 101 396.5 SF, IS 21 1 SEE DIVISION Im NOTES R1z6n U ./ 105 36A SF, 300 I I METAL LOCKER& 109 15.1 8F, 100III I 1 \v/ O TEAM ✓ II5 181,5 8F, 900 2sh SP. is9 1 2 1)VANGUARD LOCKERS FROM PENCO ROOM 125 115 717.9 SF, 15 I5 I 6 TIER MODEL 6369V,COLOR 183 IRIS. HUDDLE 111 141.6 OF. 15 10 1 _ q LOCKER LAYOUT I EY IDF ROOM ✓ I19 19,5 OF. 15 6 I 7)VMODEL 665 SV COLORAQD LOCKERS F83 IRIS CO 16 PERSON LOCKER WITH COAT ROD A102 SCALE!/"-1'-0' 124 FAX/COPY HUDDLE 120 7945 SF, 15 6 1 'Lo NORTH 123 ROOM 121 19.5 9F• IS 6 I LOCKER TYPE& ^ 0 u ' NORTH ✓ 172 19.9 SF, 15 6 1 {(mil w REF, 121 ✓ 123 1164 SF, 15 6 1 -LOCKERS SHALL BE WALL ANCHORED, HUDDLE 124 249 OF. 300 I I -LOCKERS SHALL HAVE SOLID AND PANELS. ROOM ✓125 192 OF. 15 13 I -FOLLOW MANUFACTURERS SPECIFICATIONS 120 ✓ i7 934 6p- 6 1 I FOR INSTALLATION. -LOCKERS SHALL BE ASSEMBLED USING HUDDLE / IM 1141,d SF, 11 2 RIVETS,ROOM 132 55 SF, 1 1 -RECESSED HANDLE,,/ 133 955 SF, 46 IDOOR VENTILATION.135 651.9 SF. 44 1 PENCO PRODUCTS INC,(PENNSLYVANIA)HUDDLE I_ 90.1 SF, 1 I TEL,610.666.0500ROOM 131 Sol SF, 1 1 FAX.610.666.1561138 90.1 8F, 1 1 1.800.562.1000 FOR CATALOG �• �� OPEN OFFICE . Id0 A65 OF. 300 2 1 AREA 106 / Idl 4218F, 300 2 1 IDAM O DISTRIBUTOR 36.1 NDUSTRIAL STORAGE SYSTEMS EXIT 142 1 8F 300 1 I I / 143 929.5 OF. 20 41 I TEL,208.316,1111 OF TEAM Ids 8569 SF. 15 58 7 ���'1E )O•��'� ROOM ._-Ig TOILET PARTITION AND URINAL SCREEN WALL& yU.A 'SO''� Ill METAL PARTITIONS, AR 703 1940.9 BF, 100 16 rL.TEAM •FLOOR MOUNTED,OVERHEAD BRACED %nROOM •FAST TRACK 12 HR SHIPPINGs 116 3 -$4ANLESSF STEEL TEXTURED FINISH rrl I• TOTAL 49126 SF, SATIN R.ITERVIEW ROOM JANITOR MANUFACTURER:GLOBAL PARTITIONS MY) I05 -----' TEL.631,5B6.3330 .•'TEAn I15 NO.OF EXITS REOUIRED,3 FAX.631,S86.3455 GTA JOB NO, ' ROOM ENO.XIT E%ITS PROVIDED44 � i1 WEDBITE:WWWGLOBALPARTI ION INTERVIEW % ® / III � EXIT WIDTH REQUrt2ED:(147X.2)•-1d8:4'Irjl n ROOM -----r EXIT WIDTH PROVIDE0,216" DELLCG 102 j RECEPTION COIN DRAWN CHECKED 11 CONFERENCE INTERVIEW 0 ROOM 101 JJK BFI 103 ExIT ® DATE INTERVIEW ROOM EXIT"' II/05/01 04 STORAGE FAX/COPY 10B 109 SHEET TITLE MEZZANINE 6 CODE ANALYSIS d ENLARCsED AI02 SCALE:I"•30'-0" PLANS NORTH REF, SHEET >4102 I _ n " n Y I i j i j i• i i i j j o cn�„ s�No U=C— '60 - _- ___:_ _--._-- - - -— -- —- - - - - - - - - A ROOF PLAN KEYNOTES O I Z7 Upu U O j ;`} O LLuu N z b I. NEW PREFABRICATED MECHANICAL CURBED OPENING, U — _____- U � ��' RE:d301-2. mm= 1 I I I I 1 I �❑ I 1 I 2. ABANDONED CURBED OPENING TO BE CAPPED, I I I ! I I 6 ! I 3. REMOVE EXISTING CURB,PATCH AND REPAIR EXISTING ROOF REVISIONS WHERE DEMO HAS OCCURED. 4, NOT USED I ! I I ! I I 5. NEW PIPE ROOF PENETRATION RE:A301-10 1 MECHANICAL, NEW MECHANICAL EQUIPMENT,Iffi:MECHANICAL, I i i j I I I I I 6 T. SEE DETAILS 03 4#4 ON SHEET A301FOR PATCH AND REPAIR OF THE DEMOLITION OF ROOF MOUNTED EQUIPMENT, ° II i i LEGEND I i~' j G j 7 j —•-- - ---------------i----------------------------------•—•---•---------- -------•-------•---0 EXISTING. FIXTURES FEI oI _ J -----—-—----------------I---------- -—-—•—-—-—-—-—-—-— - r.. J--------_-3------------------------•— —-—-—-—-—-—-- — —�— C I 2 EXISTING CUR BED OPENING TO REMAIN e 1 6 Ib E I I EXISTING VENT OR Ib ' I v I I .. O FLUE TO REMAIN EXISTING EQUIPMENT I I' ly CURB i0 BE REMOVED all - — — ------- - -------•— — ----------------------- --------------- -- ---•-----•----------------------- ------------- — — — II +__.—_—_—_—_—.—___—_—_—_ I_—_- {—_—_ EXISTING EQUIPMENT I j j 3 j I I PLATRORM TO REMAIN I • IJ i-- -- EXISTING EQUIPMENT WISx35 C•I� " ON CUR59 TO REMAIN I I I L______1 , I FX , ,I, II: „• _ HATCH ROOF ACCESS H 3,nnueiJf� ATCH TO REMAIN COORDINATE W G I U O ,li '' I IE 1 ; WI8X35 C•1 i 1 DUCT MECHANICAL WORK UNIT I .______--� I _____� G I !, �'!II i A301 , ILI i ❑ NEW NURSED O M IT 6 ........................ .-._........._. r; U 'i! '.(`- i OPENING,R&A-301 hu] � t W 1 li I. L_v_ - ,I .-. —_._J, NEW VENT OR M II 11 '' _r.{__ I O FLUE,RE:A-301 OM 1 :I I O EXISTING EQUIPMENT RE,A301-2 m 0 —_—_�_—_—_—_—___—_—_—_—___—_____—_—_—_—_—_—_—_{g_—_—_—_—_—_—_—_—_—_—______._____.__—_—_ _—______-_._.___-__—_— —_—_—_—_—_—.—_ _—_—_—_—_—_—_—_—_—_—_—_—_—_—_—_—_—.—_i__.____—_—_—_—_—_—__ TO BE CAPPED, I I I II xx 1 - - NEW EQUIPMENT ON I I CUR59,RMMECHANICAL U p u� ! ! I I—M I ! ! ROOF PLAN GENERAL NOTES O N co W 1 I I I ON I I I I I. CONTRACTOR TO VERIFY 1 COORDINATE DUCT CURB AND ROOF ,� 1L PENETRATION LOCATIONS,REFER TO MECHANICAL DRAWINGS FOR A C�Z I I I I I ADDITIONAL REQUIREMENTS AND COORDINATIOµ IFr)•, Ln O I 2. ROOFING CONTRACTOR SHALL FURNISH /INSTALL ALL REGLETS, co= I 3. PROVIDE THERMOPLASTIC SINGLE-PLY MEMBRANE AND COMPONENT G. MATERIALS TESTED AND APPROVED FOR INDICATED APPLICATION I I I I BY EUI N NDERWRITERS FIRE EXPOSURE,LABORATORIES,INC.(UL),FOR CLASS A - q, PREFABRICATED CUR59(FOR ROOF TOP MECHANICAL EQUIPMENT) I I I I I I SHALL BE INSTALLED AND SET LEVEL, 111�1111 I I I 5, ALL PLANES OF ROOF SHALL SLOPE MIN,���"L,F,TO DRAINS. I 6, NO PLUMBING VENTS OR EXHAUST UNITS WITHIN 10'-0"OF INTAKE OR W-W OF EXTERIOR WALL. I ! I I T• FABRICATE SHEET METAL CURB CAPS TO ALLOW FOR THICKNESS V OF ROOFING PLIES EXTENDING UP CURB FACE, 0-4 8, COORDINATE ROOF CURBS WITH HVAC EQUIPMENT, REMOVE ALL EXISTING VENTS THROUGH ROOF (ROOF — — — --- — — — PENETRATIONS THAT ARE TO BE ABANDONED,RMA301-4. �H - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - -;- - - - - - - - - - - - - - - - - - - - - - F �I 1 ®1 10. AT ALL NEW CURBED OPENINGS,CONTRACTOR SHALL PROVIDE STEEL ►"+� I ! ! L I I ANGLE FRAMING FOR OPENING,REA301-5, U I I I II. REMOVE ALL DEBRIS FROM ROOFTOP, i U 12. SURVEY CEMENT TO 1BTING PROVIDETCH PANG AND PROPER DRAINAGES iA EAKL WITH PROTECTION. j I I I I 13. PROVIDE 100 SQ FT,(100 PATCHES)OF ROOF MEMBRANE 4INSULATION REPAIR WORK BEYOND AREAS SHOWN,EXACT LOCATIONS TO BE j I I I IDENTIFIED BY CONSTRUCTION MANAGER ! ! I I W j I I I I L.L. i j j i i i j j i i w O w i i i i � L��•••r1 C:/) Lu , �° --------- —— — — — — — — — — — j — — — — — — . — — = I — — — — - - — - - - — — — — — -- — — - - — — 7---------------- ----------- — — OU O1w� U I I I I I Llz�® I I L..........................__..........._........_ I I o ::_:,......::...... I I I I 1,I m � U I ! I I I oA 'o'yo%' TE TS __________—.__ -_________________._____.___.___.—_—_ —.—.—_—_—_—_—_---O - . AR-1803 • - DAVO L.TM ER ,..G. - I . I Nf tv I I I OFti ,�'STE STER .\ �r ft ,•�` — — — - — — --------- °— — - - — ° o I I GTA JOB NO. o o j DELLGG u U_ I � i a I I a o — — L DRAWN CHECKED a —. _—.—_—________.____—___ __—_—_—_—_—_ — — JJK BH DATE i i I i i � `-O SHEET TITLE ROOF -- - ----- - --------�-------•------------------�-------- -. -- - - ---- -------------------•------------------------------------- -------------------------------------0 PLAN SHEET ROOF PLAN l�L/ lf�p1 a SCALE;1/a' 1'-U" , �I NORTH 7.8 n 2.2 I 2 a 2.9 O 3.6 ( 4 1 ( 5 1 6 CD �/ TO,FRdMI' ON H I — — _ � OC .. _-.. .-._ - .' � _ f I 2 I 2 C 7 I-F- """T' 'T -^ T,O,FRd ING 73 • Ce ..__-_"-------'------- ----.-�:v...._,-_._..._1:._..-.,-,-._.::.....-- ., L T --i�-y-J _ ...— ' —.. .::...4---.__-.-_ -." -__—_ -- ___ - _—_ _ _ _- -_ Q _,_ �----- -- = - - - - - -- - - - - T nu o . ] + _. _- o.c Z z —-^—�_ _ KEY NOTES, W -- , -I .c •-a_-�c,.`. -L 1.,L. `"'�"��" w`'- --'""`�"""�" _ 1, POWER AREA WHERE EXISTING SKaN4GE yZw -","^n'^'v",^"'^"m^v,"^"'9"^"�"'."-:,w?""T"v,m„w,l. ,-:., x..:-r ,..T. .__. ._+.Z- r r v+ _ Y ,-dt_ ""`" ... +r, f" ..ti,.,:,l:m,�+ 4^,V T'm'nTM """^F-""M1'^ ^•"',.,,""^r:.:'P'^! TMT""rn"'"' � Q - FF -_ .....;. .,,.:._.._„...:.:....:....,,.....,.,. _,., .,. / Z 1 ..L=�. .L 1,.. 7.,Y ..j r U r r , I , c � Tl n ,_, -r J WA8 REM ED _, ..,.,....,...,. : _{ i _� :�� r? rl �Jx `mot ,-..,,' _.._..,,_ L.J ... _. -_ . .,. ..: ,. .. l... ....1 _. J. - .�.�_r-t. L-,t r" Jos tr7F- '- -... 1. .,f. i_�:: .:j:..ry - - ( m,t.....,:,r,•.:", : -- -- A :i:. T. .I ...r.L 1. �T ._L. m Lu a., . y , , ....,A .. A ...., : '-ti _iAY,. :.% '.1 1: lr_„ .L, Z I�= Y ,. ,, •.,. ,.._ J.. _ X..,...r .... :... ....:..... 1 _.r ...i -rJ'! .\:�li. - __ __ P T EP'.. ,...,,,. ,..::.,.,.,.,.::(.r 'w 4 CH dND R 4R WHERE EXTERIOR SKsN4GE 1.._,.,.L., _.., ..,-:.... t,....... ....:..". .... . ...,..: .....,.::..:.. .. _ .... ....,...LI :!...*..., .,.� a1.,a) '1'i..[i'`',•�•.:'1,1„ 'Y.,. ,.,IJ1..7,; I.. 1 .:,. '-+.. T: M yt In-Yt' { +-ct:;V, WAS REMOV D AMT TO MATCH IF E........ .... ....... ,..r.,._,. r..,,... ..,: . ,., �`^u. .-['.�S_ pt::-L #'_., S. C REQUIRED. E P ... ,.:-.,,.,.,,:.... .,.,.., ,._. .,..,..._:.........:.. REVISIONS r Z r / ,......:' ,...7,. ..,t r...,.1....,6, ..,,r. ,A r._,.,I T..,...L,. ,:....,,. % .,�/. .I, �I'�::, �A t. I .. .,.. .. .. ..-'_. . ...... .,... ....I .. i .: . : I.1a.<:.. :L1.'.. ;:1.T_. �' :''!,"1 . .,' .",: ., ,, ..:i: :T:. r.._. _'C ...1.. 3 NEW EXTERIOR DOOR IN EXISTING C ,". ... ..........:._.: ... : ._.,... ..,... ...,...:....: .; :.,_.,_.. ., r :.L. -L71. -L ._S_... .1:�_L..:Li._..LLT ._ ......... ... .............. .._. .... ...... r - - - -- ... .... ._ .... ._ .. ,.. ... / OCKOUT RE,AIOI 4601. x._ ....... ......:...... 7. . .. i'"_..._I ., 1. . .. A.... .: .. ..l....:... .. . -. .__ ..A . .:., .,-: L'i'_".. .L,. ."T"^,"?" - - - - - r - - 1-1 I: MU *.,...,.,..,.. t' tt ..,...., ... .....:.......:,...,..:......,,_.,....:.,.._...... .:,.,:......,. ...,..,,., i.._.,..... ..,..,.. _...,. .!.r.," : L �i�_]Z��i._1... __ I7 4. NEW STOREFRONT DOOR RE,AI01.4601 , , , , , , , , r , , i 0 ..,,r._,..,,, , ....,. ..... .. ... .. ..,.. .. .-..:.... L _.. ! :..I ,,." .. :.'`:.':.-'. ...A... ..._ .,. ':'.:'t'" .L.. 7:.,.. ,r-. is (.' I. .' 7.... ' I _ !. L r ._ .... ...;....-., _. . .... . .. .... i ... .:.. :. ......._ _.. .. ..., . .. .. ,. . ...... 7. _r. 7-:..:L:..I. I .L�:C:1 t 1":':'I::.`. L.:�_I� - '1: S. NEWSTOREFRONT I , r : � , 1 , /r _,..: .r.,,.,.,. ._. :r-` N WINDOW G1499.RE:4101, . .� y .-, , , ...r...4. .,, :....... ..,_.. ,A....,. .....Ir , .,. �I '�Ay `r� :.�.� rJ�.. ..r..Y r. ,.-_ ...': .........:.........,:....,a.,.._.:.:,.. .....,.:..•.,.:., ,.:,.l.,. ..,".., -. ". .. ,...:,. r y y y .:.! - ..5.:.....7- - LT LS.T7._1.1 ...L... A601. ,.,..,t1 _.- .,.,.-..,: )... ... L,.,-,:..l...,,..... ... .... ....A,.,.- ....,..,. .:. !.. ,-...,: ,.t,., ,..,. A ,.I, ,i, „7, .i,-. i,. ., 'Z. -f.. .1.�7_.. L...... _,., .. -.., .. .. ... �' .'....,..... '. _. r - ..... ... T.....T 1. T .:.1... .2 S 7 t I _I.- -1. .... .... ....... i.. .l ., ...f .:.,. , r, .... ,"..... .. ... - i ,, !..,, ;,t - / - T a. PREP AREA TO RECEIVE NEW 91GNAGE, . i : .r.. r. :.:_,..r.., .r_ .. .........-........._..._ .... ......... .... ................. .... - ..........._. . ..__........... .,,:... ......._.. ......... ................. ............. - ..-_ ___..-.T:... .......,..... .. ..... ..,,........ ... .... ..d.,..... .. .. ...... ....._....... .........., ..,.d... ...... ..., .................. ... - .. ... ..... ... ... .,.. .-.,. ....... ........ ..I..... .. ........_ .. ................ _- ...._..,...., FISL-FL . ...,.... .. .... R-. SOUTH 6 6 6 /\I ELEVATION EXTERIOR FINISH SCHEDULE MATERIAL COLOR NEW SPLIT FACE CMU PAINT TO MATCH EXISTING RUNNING BOND A B (�) (�) Q Q G `rr'' ��rr'' EXISTING SMOOTH FACE CMU EXISTING T—IT— 1 r'��` RUNNING BOND I• I I I ® NEW SMOOTH FACE CMU PAMT TO MATCH EXISTING -: RUNNING BOND . .. ..,. .".......". .... ....... .... .. ..... .. ......... ." .. .. •_•-__ ., ................"........_.........-........-................,..............................._......._......;, :. .. ..__..... ............ ........... ..... .............................. ......,- -.___._.,,._«._____.__•_ �.__............_...._._......_...... ........_......_.._..............._...._...........................:_..:--..:..::.....:.:....:.:....::...:'.'....:. ... FACE M I EXISTING SPLIT F E X C CMU EXISTING —_,_-...- _ _ _ _ _ _ _ NNING BOND _ SI ,:.- ,-, r•-,r,,... r (..,.. ..... .........._........."......................,..... _............. .-.. .. T.O.CMU --- -..�.. " J I , t _ ......_... -......_....._:...:...::::.........._.. ..:.::::'.:__.:-:...".:._:::. . ...._........_.. .. .. .. .. ... ._ .-.... .. .__:...... ..:...... ." .. ... .."... .... .. ..,,.. .. ...,:'.:' XS NG S EXISTING r i ... E EX NG .::: .... ............._...:..,.,......... ..-....... ........_. _..._._...... .._,.... -_._ —__ .. .. .... ... ... ..-._...__....... ..... .._........ M ._ ..._ ._......._....._........ ._.._..........._.....-. .. ., ....}.,......_...._. .- ...._...._. ..... .... ........._..."......___............._....._ ..__...._,.............I............__ ........... - - O M _ .,......... _...... ._ ... .... .............. ... _____.__ .... ... ... ............-.. ..-...._.......... ,... .. ... ...I-.... - ...................... ....:'._.. ..__....._......................... ...: ., .. �v ... .. ........:."._: ..._.._._......................_............. .. ......._._...... .. ..... I .-.__-__.-�_ . ....-..._... .-...._.............. ..... _ __— ............. .... ... ._. «., .. .... ....-_........._... :.... ..... .... ......_.. . . .... -..:/ 7 O-- ::..:::.::::..::..:::::.:..:::'.:...:::::,.:...::::.::..::::..:...::'.....::::_:.::_.....::::.:. :::::::::::::::::::::::::::::_:: ::::.:::::::::::::::::::::::::::::::: :::::::::'::::::::::::::.._::::.::::::::_:::::::_:::::::::::�:::::::'::::::.:' F-._ ::::.,.:::::':::':.....:.::.:....::::..:.:.::'::.:.._:::......::::.:..:._::::::::::_.:.__:'.::_::.:.:.::::.....::::::.,.:.:.:':.:.::".:.:.:_'::..:._:_.::.:-:...:::"::. _:'.:::::::::.:.;.:::::.........:.:.":'::.:.::::.:::::-.::.::':::._:::.:._::::.._::::...._:...,:.:.:::_:::::::::.::::_::::::_:.:::._.---.:. m—_--.-_.__. ..._.._... .:--.. .. ...:..... _..'::::... .. .. . — .. .".:. :: :::::.'...::. -.. __:'.-.::..::' .:: '.:: ..'_:..:_"..." ....:: ..:., .::',':...'.....................:..._.. :::::::. ..:. .....- ... ._ .,,,... ... ... .. ... .__.. ... .......,_. ... -. .. .,I .__.__ .... ... _......_..._. ... .... ._.. _ _ _ _ __ _/ ... ..... .... ..... .... .... ... . ...... ..................... ... .. ..-... ..__.. ......... .-.... .... -_ .. - - __ __ - .:1:: '....... ... ..... .. .... ... ......... ... ..... ... . .... .. _ .... .. .. ....T .". .. ...... .. ... FL,« ..::..... ....... FIN. R I O 121 -0' � O 2 ELEVATION T. crnJ = w ^ �''II''1 �00 / \ BOND BEAM O = ;O 00 Vie::_I._0:, CL . ^LI I 1 Z > I-~"i to O D_ r^ r^ �./J U) 2- I%' 'B' DECK 2_ FT BOND BEAM \ U Z FX STEEL JO19T I•-I, = 1� W /'V) • Y..G.a BOND BEAM W (�L� W Q Z a U V �', 0 W B' o • • � z W - w = 11 1 ►-- U O � NOTE: RE: A201-1 ! p201-2 FOR FINISH OF BLOCK USED. 1 Q0 U 4 �y a i•. . •g� - -El_ °�tE or 1.0% '�P +y''" N CTA O G MCHITECTS AR-1807 , O�Vq L.TURNER H .q,1!$��a `� f O, ICS A ( � I r.' h 102 -4' 4' HIGH CMU ? CTA JOB No, T.O. 4' HIGH COURSE COURSE c DELLCC DRAWN CHECKED JJK BH 4" CONIC. SLAB DATE tm0'_m. II/05/01 1.Ir FIN. GRADE T.O. GLAD GROUT BLOCK FULL - SHEET TITLE BELOW GRADE EXTERIOR ELEVATIONS .1 fl . , I SHEET _J 1. 4 �� ,4201 . . �,�TYP.EXTERIOR WALL SECTION . AIOI Y::_"C" ,. . COL, WIDTH 6" 2 X 2 PRESSURE TREAT �O BASE PLATE WOOD NAILER TYP. 5' 24 GA, COUNTERFL49HING. - CRIMP CAP TO FORM I-PLY R30 INORGANIC - 18 GA. G.I. CAP, AT CUR R FASTENERS THROUGH - * TS CENTER PEAK FOR FELT, MOPPED FUTURE UNIT AT BANK SPACE NEOPRENE DISCS AT EACH _ RE: 9/LA301 DRAINAGE CRIMP CAP TO FORM CENTER CORNER AND 18' O.O. MAX DIVISION NOTES o cn 5 I-PLY e30 INORGANIC PEAK FOR DRAINAGE. O D + -- 22 GA. G.I. FLASHI FELT, NAILEDPATCHING I... 7 ROLLED BEAMS �" PLYWOOD, NAILED 4 SEALANT AROUND PERIMTER ROOF-PATCH NGINGAFLASHING END TRIM: CV Y T y MECHANICAL DUCT �•J J ROLL DESE THROUGH GLUED TO TOP OF CURD HOT AIR WELD ALL SEAMS PER THROUGH ROOF PREFAD CURB, BY MECHANICAL •PATCH ROOFING A8 REQUIRED FOR NEW ROOF = Q W H N DECK, RE: MECHANICAL CONTRACTOR OPENINGS WITH MATCHING SINGLE-PLY ROOF Z ug I I 8 MANUFACTURES RECOMMENDATIONS SPECIFICATIONS. EQUIVALENT MATERIAL • ------� NEOPRENE WASHERS SUPPORTS =r-1 V AT 24" O.C. .REMOVE EXISTING FLASHING THERMOPLASTIC SINGLE-PLY NOT AIR WELD ALL SEAMS PER ------- - - Y v y MANUFACTURES RECOMMENDATIONS THERMOPLASTIC SINGLE-PLY iy U Z U a FROM CURB SUPPORTS MEMBRANEMROOF, 45 MIIL THICKNESS - ROOF MEMBRANE, 45 MIL THICKNESS -PROVIDE COILCOdTED PRE-POINTED Q LU _Z Z BABE PL �° \ WITH 15 MIL OVER SCRIM LAYER THERMOPLASTIC SINGLE-PLY WITH 15 MIL THICKNESS OVER THE GALVANIZED STEEL SHEETS OF A MINIMUM () Q 0 J W ISOLATION JOINT \ I SCRIM LAYER, 0.028 INCH THICKNESS FOR FLASHING AND EXISTING THERMOPLASTIC REMOVE EXISTING CURB, MEMBRANE ROOF, 45 MIL THICKNESS I m DIA.. HOLES .� FLASHING 4 NAILER WITH 15 MIL MIN. THICKNESS I TRIM d8 REQUIRED. SINGLE-PLY MEMBRANE ROOF fA) PLACES TS COL., RE: A101 _ OVER SCRIM LAYER POLY ISOCYANURATE, p CONIC. INFILL SHALL d' CONC. SLAB, - e @'` ° I ° I PROVIDE ED STEEL S PRE- HINTED IR RI i-.NE1.,ROOF I?IP,+!I�1T.ION,TR. I, �I, MATCH EXISTING GALVANIZED STEEL SHEETS OF A MINIMUM REVISIONS °` r, _ j 1 IJ I /u THICKNESS �.., "` r 11 --- �" I MATCH EXISTING INSULATION� OF 0.022 INCH THICKNESS FOR RE: A002 Sa::!,.. :..•,I.r^"!`'„^--`:: 111 II I I METAL DECK COUNTERFLASHING AS REQUIRED. HAVE VERT, FORMED SEALANT AROUND • SIDES WHEN T.O. FTG. Illm I R I I PERIMETER '"'""""::""; ' - : II II nbp EXISTING ROOF III II THICKNE99, POLY ISOCY4NURATE, LOWER THAN ELEV. 99'-0' /�J��` 1 1 I t I t u INSULATION I p I TYPICAL BASE PL j" EXISTING ROOF DECKS Iluull Inuul '""",°°� i EXISTING STEEL JOIST III III II II III ul EXISTING ROOF JOINT SEALANTS SUPPORTS ................. D n ....... INSULATION WITH J, I'/,' NON-SHRINK ......... ,.. - .- ...:IZZT S PROVIDE ONE OF THE TY p, SLAB GROUT "". ...M TING - FOLLOWING. NOTE: REPAIR FLASHING OPENINGS 4T CORNERS OF EXISTING EQUIPMENT ;,,,,,; ,..?_:, „-`;> '+ ' a e TOP F EXISTING /� D AT I 4' %6' X'/4' METAL PLATE PRODUCT J I TL �- O S I AT 4' 0" O.C. f 4 MIN., 1 A REQUIREMENT CURBS, FIELD VERIFY ACTUAL PROBLEM LOCATIONS W CONSTRUCTION MANAGER. f TOP OF EXISTING I1 I I1 ROOF DECK. a CORNER) WELDED TO CURB < d- �" DIA. A.B. 4'W PL , $WEEP AREA OF REPAIR CLEAN OF DEBRIS. ROOF DECK ANGLE, /ONLY REQUIRE �99'-4" A- ,' DIA$ - EXTEND 4" CONDUIT, PIPE, REFRIGERATION CURBS W A/C UNITS) I. TWO-PART POURABLE URETHANE SEALANT: 7�p, FTG- II ABOVE PTO. W/DOUBLE 2. PRIME FLASHING WITH APPROPRIATE PRIMER AND FRAME ABANDONED PENETRATION ETC. TO BE _ I EXTERIOR AND INTERIOR JOINTS IN 1 ANGLE SUPPORT AT HORIZONTAL SURFACES ON CONCRETE; NEW METAL DECKING REMOVED. FULL PERIMETER OF BETWEEN METAL AND CONCRETE BETWEEN NEW ROOF OPENING W DECKING: CURB MASONRY AND CONCRETE, INSULATION, TO MATCH EXISTING AS TO MATCH EXISTING, pp li NUTS FOR LEVELING ALLOW TO DRY THROUGHLY. SHOWN W ANGLES A. •VULKEM 245"; M4MEC0 U --� --� 3, SEAL ALL OPEN LAPS OF CURB FLASHING WITH TO MATCH EXISTING WELDED TO EXISTING HOT AIR WELDS AND SEAM SEALER. OPENING STRUCTURE, r 3'�"X3'•0 INTERNATIONAL, INC. B. 'NR-200 UREXPAN"; PECORd, 1 INTERIOR FOOTING: ABANDONED CURBED OPENING: PLATFORM/CURB OPENING: REMOVAL EXISTING: ROOF PENETRATION REMOVAL PREFABRICATED CURB DETAIL CORP • N.T.S. 1" - 1•_0" IIa• - ,,-0" C. SEALANT'; PAVING N.T.S. RE: A103 RE: A103 RE: A103 RE: A001, A101 RE: A103 D. PRODUCTS 0•DITREMCOEMCORP, INC. 2. TWO PART NON-SAG.URETHANE SEALANT: EXTERIOR AND INTERIOR JOINTS IN VERTICAL SURFACES OF CONCRETE OR MASONRY; PERIMETERS OF METAL FRAMED IN EXTERIOR WALLS; OVERHEAD OR CEILING JOINTS; AND ON INTERIOR OF GLAZED STOREFRONT SYSTEM. A. "VULKEM 922", MAMECO 12 B. SIKAFLEX 2X NS"; SIKA TURN LEAD FLASHING DOWN INTERNATIONAL, INC, 301 CORPORATION. INSIDE PLUMBING VENT PIPE 2" 5%a' METAL STUDS L SEALANT C. 'SONOLASTIC NP21; SONNEBORN 9 16" 0.C, FLOOR - %" TYPE "X" GYP fv DRAW BAND REX, INC. 3- 810 TEK SCRELIS MID HEIGHT BUILDING PRODUCTS DIV., CHEM TO DECK Fc� 2X30 / OF WALL 3, ON PART MILDEW-RESISTANT SILICONE: .1.. EXISTING ROOF DECK /, 4 LB. LEAD PIPE JACK, 1 �• END PL I FURNISHED BY TRADE INTERIOR JOINTS IN VERTICAL / RESPONSIBLE FOR PENETRATION. SURFACES YP, r P40MB CERAMIC PLUMBING 1 I / H88 COL„ _ 2 I SET FLANGES IN ASPHALT t- o PLASTIC ROOF CEMENT OVER FIXTURES, KNOTCH FLANGE STUD WALL L ROOFING PLIES RE: 9/A301 �`�_1_ -----I AND BEND WED, TYP. 111'-O�Ap I A. "DOW CORNING 786"; 0014 CORNINGr---------- 3509162-33 B.O. BEM - THERMOPLASTIC SINGLE-PLY CORP, /�/ IA______-L_------ 9 4'-0" O.C. MAX. 3- •10 TEK 9CREL19 I MEMBRANE ROOF, 45 MIL THICKNESS D, •SCS 1�02', GENERAL ELECTRIC CO. 1 1 M MEQ EO 3- #10 TEK SCREWS 2 MAX• 3506162-33 j',IX-I'/aXWIDTH OF BEAM UITH IS MIL THICKNESS OVER THE C. "863 e345 WHITE"; PECORA CORP. ~ O cif 2 MAX. I SCRIM LAYER D. 'PROGLAZE WHITE"; TREMCO CORP.L--- --- ------- 16 GA. TRACK I4'-0" O.C. MAX. �' BOLTS � �M T --- I 3- 910 TEK SCREWS ROOF INSULATION. POLY-I90CYANURATE, 4. ACRYLIC-EMULSION SEALANT(LATEX): __________ HS9 4X4X% -- MATCH EXISTING THICKNESS Ir�1 W 0 fi -----I 3- HILTI X-DNI PINS I I INTERIOR JOINTS IN FIELD-PAINTED \ In O (- L3X3X16 GA,X6' L------__-- ---I W 1' EMBED. I I VERITOAL AND OVERHEAD SURFACES N STUD WALL I ROOF DECK I AT PERIMTER OF HOLLOW METAL DOOR fY] I CONDUIT OR PIPE CONCRETE OR CONCRETE MASONRY; AND METAL STU I FRAMES, GYPSUM DRYW4L, AND ♦_ �C 11 16" O.C. W/ 6/e' GYP. - ---------------— W ALL OTHER INTERIOR LOCATIONS NOT BD. EACH SIDE TO i6" I O ABOVE CEILING 4'-10" FLOOR SLAB INDICATED OTHERWISE, I A. 'AC-20"; PECORd CORP, � B. "SONOLAC"; SONNEBORN BUILDING TYPICAL BRACE DETAIL Q BRACE DETAIL TS TO W BEAM CONNECTION 1 ROOF PENETRATION PRODUCTS DIV., CHEM REX, INC. O U POCKET DETAIL (� �;" ,,_m. Y' - I'-0 1• 1'-0" c. 'TREMCO ACRYLIC LATEX 834"; N ce I1 '5V W BEAM, ' 1 RE: A101 RE: 4101 RE: A103 TREMCO, INC. w cf)^ RE: A101 Ay,' 9/4301 RE: A10I EXISTING SUSPENDED WALLLU CO %' DIA Xl' HANGER RODE I IN L FILL W %a" PLYWOOD BY MODERNFOLD N" I TO MATCH EXISTING AS REQUIRED. PAINT Lu GYP. BD. ILo, UZ OCROSS BRACE 9 AS'- O.C. 3%a" MTL. 8TU0 . ' T.O. FRAMING •-.--•----••. _ 9 24' O.c. I .I.. .. RETA6/430� ... ,. EXISTIN IF CEILING OL IQ, TS COL., FIXTURE G4 LORNAMENTATION ,,,I• RE: 91430I EXISTING LIGHT IGHT TO REMAIN it '-0" HANGER BRACKET TO REMAIN FIXTURE 4 ORNAMENTATION EXISTING 4100D OPENING DY MODERNFOLD TRIM TO REMAIN %' TYPE 'X' BAFFLE JOINTS-�1- 41-I STEEL TRACK AND GYP BO I I EXISTING WOOD MUST BE TAPED I ALUMINUM GUARD RAIL VINYL BULB SEAL TRIM TO REMAIN EXISTING WALL �+ PREP42NTED OFF-WHITE I JAMS FINISH SAME TO REMAIN AND SPACKLED W A8 PANELS EXISTING WALL Y•-�"�EXISTING WALL � EXISTING FRAMING I� I CAULKING BETWEEN FINISH TO REMAIN H�-/--�1• BY OTHERS = = STEEL, 4-WHEEL I JAMB AN WALL DIAGONAL BRACING, FINISH T REMAIN - TO REMAIN ' 91 I BALLBEARING TROLLEYS SUSPENDED RE. M/A30I FRAMING r- ------ --.......... - �+ I .. WALL TO REMAIN SUSPENDTO 4/i VINYL TOP SEAL I ., I• NEW SUSPENDED ACOUSTICAL EXISTING WOOD D 19 O CEILING 4 GRID TRIM TO REMAIN %" GYP. BD. i EXISTING :�... � .. .. ►-I�-I 1 �1 �: ...� -. 1►•-IIU-•�� H f CEILING FRAMING , = I SOFFIT- VERIFY _ ���Y M 3%" METAL STUDS, VERIFY I 9 16" O.C., FLOOR TO ly CAULKING BETWEEN SOFFIT ALIGN NEW FRAMING W NEW SUSPENDED TYPE "X• 108'-3�"-I09'-9�' EXISTING SOFFIT JAMB AND WALL 1/e EXISTING SUSPENDED WALL ACOUSTICAL CEILING y J AUTOMATIC DROP SEAL GYP. BD, TO REMAIN L^r/ TS COL., D.O. FRAMING- VERIFY FRAMING TILE! GRID PROVIDES 11/2" OPERATING I RE: 9/A301 ALIGN NEW FRAMING W - CLEATANCE(4Ya" -1") JAMB FINISH SAME 3Ya" METAL STUDS 9 16" O,C. EXISTING SOFFIT FRAMING- SEAL ALL EOGE9 W ///'''��� A IWODFINISHED 8 PANELS TRIMTTO REMAINFLOOR TO SUSPENOF�WALL FLOOR TO SOFFIT 16' O C. W FLOOR GYP. BD. EACH BIDE eWALL F FINISH WALL FINISH EACH BIDE O Z .. .. .. .. .. RE: Asol RE: A50 HINGED JAMB ADJ. LEAD JAMB � WALL a EXISTING: SUSPENDED WALL 1 � WALL a7 EXISTING: SOFFIT U � V 1 1 VERTICAL SECTION 1 1 6" - t'-0" 1 Y2• III"- - -O IYa" - 1,-0„ 6" - I'-0" RE: A101 RE: 4101, A901 RE: 4101, A901 RE: A101 RE: w O w E%ISTING 9U8PENOED - --- WALL 4 FINISH TO REMAIN v ROOF ✓� //� STRUCTURE, W - (TYP.), T.O. FRAMING -••- T w 1 2'/a' METAL XI STING LIGHT Qa4 STUDS / FIXTURE 4 ORNAMENTATION TO REMAIN EXISTING WOOD GLASS FIBER TRIM TO REMAIN "c INSULATION FIRE DAMPING EXISTING WALL (TYP,) q - TO REMAIN 26' O.C. GYP. BRO. ON ME TAL. EXISTING WALL � I NEW SUSPENDED JOIST SPACING I FRAMING WHERE" 16" x CONT. x� FINISH TO REMAIN ACOUSTICAL CEILING I6 GA, B LoREAK OCCURS TILE 4 GRID AT ACCESS METAL SLIP u :,.::..•-•q,-:::...- DOOR ONLY SOFFIT FRAMING CONNECTION cc u _ --------_- d' X 6" X 16 GA. NEW CEILING DL.00KING METAL STUD .BREAK METAL BLIP 110'-0• „ FRAMING AT CONNECTION EXISTING SOFFIT- VERIFY I 24" O.C. (TYP.). SOFFIT ACCESS RE: A101 EXISTING WOOD ALIGN NEW FRAMING W DOOR RE: A601 4 DlvlexoN a NOTEa PARALLEL PERPENDICULAR BOTTOM d 5 TRIM TO REMAIN EXISTING SOFFIT FRAMING Gyp, BOARD EXISTING SOFFIT 4 FINISH 3%2" METAL STUDS 9 16" O.C. ---------- TO JOISTS TO JOISTS OF DECK " TO REMAIN FLOOR TO SOFFIT - L11 NOTE: DO NOT FASTEN PARTITION WALL FRAMING OR FINISH TO 1 � EXISTING LIGHT FIXTURE %- GYP. W. EACH SIDE SLIP CONNECTION. MAINTAIN 2'/a" MIN. FOR DEFLECTION. yy�� TO REMAIN WALL FINISH GYP, BRO. SHALL BE PAINTED AT ALL PARTITIONS EXPOSED •• Qm RE: A501 TO MAIN SALES. WALL a EXISTING: SOFFIT 1 `� SOFFIT ACCESS DOOR 1 PARTITION TO BOTTOM OF STRUCTURE 1CTA 3. . ,,_0. .. � o �i' - I._0„ RE: A601, A901 RE: A703 J •�P 1 RE: A101, A901 �,N MCHTECTS AR-1803 -_ � DAVID L.TURNER - o, CTA JOB NO. 5 DELLCC DRAWN CHECKED JJK Em DATE II/0$/01 SHEET TITLE DETAIL S SHEET a I - . GIRDER G6G O =7 TCl TC8 c4 V4 LJJ Q N 20 V2 V3 V5 V6 V1 - = Q Lu STRUCTURAL GENERAL NOTES u Ir�1 Z � 3 5 l lR 5 3R + +++ .+.r+.r+r+.. xxr r r+ +r r +r,r «,r,r. + rr .r,r,r rxrrr,r r,rrrrr .rx xr«r 2 v=U U R• 2 4 6 e eR 6R 4R D_ U Z U< TAGGED " 2R TOP CHORD PANEL PT CONCENTRATED LOAD A, GOVERNING CODES •N Z O Z vWU NG END - GREATER ANGLE FROM CONCIENTRATED 1) UNIFORM BUILDING CODE (UBC), ISS1 EDITION ro m= GIRDER GAA - THAN b" LOAD TO PANEL PONT 21 AMERICAN CONCRETE INSTITUTE (ACI), 318-95 V4 V5 AT OPPOSITE CHORD 3) AMERICAN INSTITUTE OF STEEL CONSTRUCTION(RISC), LRFD 2ND EDITION 1994 20 V2 V3 v6 V1 v6 REVISIONS /\ B, DESIGN LOADS AND CRITERIA 3 5 l 9R 1R SR 3R / \ / \ 1) GRAVITY LOADS (PSF): 2 4 6 e 9 BR \ / \ 2R - LOCATION DEAD LOAD LIVE OR SNOW LOAD TAGGED / \ / \ ' END ROOF 20 25 - 2) WIND CRITERIA: 80 MPH / EXPOSURE C NOTE, GREATER I: 1.00 RE:SCHEDULE FOR REQUIRED WEB TYP WELDING !MODIFICATIONS. - THA� �■ / 3) SEISMIC CRITERIA: ZONE: 2B i 6=6 yQ �a RE:SCHED. BOTTOM CHORD PANEL POINT J CONCENTRATED LOAD C. MATERIALS READ.WELD 17 CONCRETE: PORTLdND CEMENT ASTM C150 TYPE I/II OR UBG STANDARD 19-I WE EXISTING REQU82ED AVAIL ADDITIONAL MEMBER DETAIL FLY ASH ASTM C6I5 CLASS C OR F - 20> MAX BY WEIGHT MEMBER WELD(IN,) WELD(IN.) WELD(IN,) WELD NEEDED(1N.) SIZE CHORD MEMBER TYPICAL STEEL JOIST REINFORCING WHERE WATER / CEMENT + FLY ASH = 0.45 MAX CONCENTRATED LOADS EXCEED 100 LBS 25 DAY F'C = 4000 PSI, ENTRAINED AIR EXCEPT INTERIOR SLABS 2 23.1 25.1 23.1 2.0 L 3X3X0,281 C BETWEEN PANEL POINTS 1" MAX NORMAL WEIGHT AGGREGATE 2) REINFORCING BARS: ASTM A615, GRADE 60 3 14,8 16.5 15.4 I,l L 2'/j X1'/j X0.212 B iG - AA ,. - 3) DEFORMED BARS: ASTM A106, GRADE 60(WHERE INDICATED TO BE WELDED) 4 16.8 18.5 23.1 1,9 L 2'/j X2'/j XY4 A WEB MEMBER / TYP.BRACE AT CONCENTRATED LOADS 4) WELDED WIRE FABRIC: ASTM A 0-1 FLAT SHEET MATERIAL !�/. 5) ANCHOR BOLTS: ASTM A301 OR ASTM A36 5 10.5 12.5 16.0 2.0 L 2'/j X2'/j X0.191 d RE:SCHEdJLE ",I'-0' 61 STRUCTURAL STEEL: b 14.4 15.1 15.9 1.3 L 2X2X0,131 A 45 W SHAPES ASTM A512 OR A36/A512 DUAL GRADE, FY = 50 KSI V3 5.2 6.5 Id,4 0,0 L I�j XI'/jX0.110 A!B OTHER SHAPES ASTM A36, FY = 36 KSI 1 6.6 1.2 15.9 0.6 L 2X2X0,163 A PLATES ASTM q31 FY = 36 KSI „q 8 144 15.1 15.8 1.3 L Iyj XIYX0.II5 A D6TAL •A• TUBE$ ASTM A500 GRADE B, FY = 46 KSI jQ$ N.T.E. 7) BOLTS: ASTM A325 TYPE I UNCOATED, STEEL TO STEEL CONNECTIONS V4 I4,4 IS.I Id,4 1.3 L I%2 XI%X0,I10 B!C B) WELDS: F1X-EXXX FILLER METAL SHOP, E10XX FILLER METAL FIELD D 8R 9.4 9 d 15.8 0.8 L I!/j XV/jX0,115 d D, FOUNDATIONS 6R 11.2 12.1 ISA 1.5 L I'%XIY XO.136 A!B 5R 8.2 9,4 15A 1.2 L 2X2XO.213 A!D GIRDER WEB MEMBER 1) FOUNDATIONS HAVE BEEN DESIGNED WITH 15M PSF BEARING PRESSURE. SEE SCHEDULE 2) PLACE UNDISTU FOOTIRBEDNGNATURAL GRAVEL SOILS. S ON UNDISTURBED NATURAL GRAVEL SOILS OR ENGINEERED FILL PLACED OVER 4R 14.5 15.1 15.9 1,2 L 2X2X0.213 4 Q 3R 14.5 15.1 16.0 1.2 L 2%X2yj XYi A -4 A106 REINF, 3.12 7R 22.8 24.1 25,2 Ls L 3X3X0 A E. CONCRETE TCl - - - L 4X4X0.4 X LENGTH OF.438 D WEB MEMBER 1) PEFORM CONCRETE WORK IN ACCORDANCE WITH ACI 301-96 "STANDARD SPECIFICATION FOR TCD - - - - L 4X4X0.438 D STRUCTURAL CONCRETE" UNLESS MORE STRINGENT REQUIREMENTS ARE INDICATED, 2) MECHANICALLY VIBRATE ALL CONCRETE PLACEMENTS EXPCEPT SLABS LESS THAN 5" THICK. 2 21.3 73.0 22.7 I.l L 3�j X3%X0,344 C DETAL 'D' 3) DETAIL REINPORCING BARS ACCORDING TO LATEST EDITION OF ACI 315, 3 19.6 1S.5 22.3 0.0 L 2Y2 XV2 X� D N.T.S. 4) MINIMUM REINFORCING BAR COVER: 3" AT UNFORMED SURFACES EXPOSED TO EARTH O M 4 14.6 15.6 72.8 1.0 L 2'/j X2Y2X� 4 2 OF WEB EACH DE 2" AT FORMED SURFACES EXPOSED TO EARTH OR WEATHER FOR #6 AND LARGER n M 5 14.E 15.E 15.1 I,0 L 7'/j X2%X0.217 A IB RE.SCHED, 1 1/2" AT FORMED SURFACES EXPOSED TO EARTH OR WEATHER FOR #3-#5 I4�r/ M M 13 6 16.8 18.0 15.6 1.2 L 2X2XO,I63 B i C REQD,WELD 3/4" 4T SLABS AND WALLS NOT EXPOSED TO EARTH OR WEATHER ►� co I 5) SPLICE REINFORCING BARS BY LAPPING ACCORDING TO THE SCHEDULE ON THE DRAWINGS. PLACE V3 5.4 6.8 14.2 1.4 L Iy7XIyjX0.110 A!B ZCHORD MEMBER MECHANICAL CONNECTORS WHERE SHOWN, SPLICE WWF SHEETS BY LAPPING AT LEAST ONE M 1 6.9 l,5 15.E 0.6 L 2X2X0.181 A PANEL WIDTH(TWO LONGITUDINAL BARS IN CONTACT). D 8 12.0 12.0 15.5 0.0 L Iyj XIY2XC.115 B 6) WELDING OF REINFORCING BARS IS NOT PERMITTED UNLESS SPECIFICALLY DETAILED. U 00 1) REINFORCE OPENINGS THROUGH CONCRETE WITH 1-#5X4'-0" REBAR DIAGONAL EACH FACE, EACH V4 5.4 6,8 14,2 1,4 L I�j XI�jX0,i10 A AB - CORNER IN ADDITION TO JAMB AND HEAD REINFORCEMENT UNLESS SHOWN OTHERWISE, Q N 9 1.6 8.3 15.6 0.1 L 2X2XO.163 A!B WEB MEMBE(j 81 SECURE ALL REINFORCING, INCLUDING WWF, IN POSITION WITH CHAIRS BEFORE CONCRETE --ii [p 6R 16.0 16.0 15.6 1.0 L 2X2XO.163 B!C RE SCHEDULE PLACEMENT. CONCRETE DOBIES MAY BE USED TO POSITION SLAB ON GRADE REINFORCEMENT, 9) TIE DOWELS IN PLACE BEFORE PLACING CONCRETE, DO NOT STAB OR "WET-SET" DOWELS. LL•5R 13.9 13,9 15,1 0,0 L 2'/j X2'/j X0.191 B R%X2X0'-8" 10) ROUND ISOLATION JOINTS SHOWN AT COLUMN LOCATIONS MAY BE SIMILAR SIZE, DIAMOND SHAPED CHORD AT END AT THE CONTRACTOR'S DISCRETION. p 4R 19.3 209 22.8 1.6 L 2%a X2%X% A I 3R IS.22 23.5 23.0 1.1 L 3X3X0. A PETAL 'C' F, STRUCTURAL STEEL Ql ZR 22.4 23.5 22.9 I.I L 3X3X0.313 C N.T.B. O REiGIRDER LAYOUT 1) DETAIL, FABRICATE AND ERECT STRUCTURAL STEEL IN ACCORDANCE WITH THE LRFD, 2ND EDITION iC OF RISC "MANUAL OF STEEL CONSTRUCTION AND RISC CODE OF STANDARD PRACTICE," CONTRACTOR FIELD VERIFY 2) STEEL TO STEEL BOLTED CONNECTIONS SHALL CONFORM TO THE CURRENT GIRDER CHORD MEMBER "SPECIFICATIONS FOR STRUCTURAL JOINTS" USING ASTM A325 BOLTS AS ENDORSED BY RISC. ►I+y W co SEE SCHEDULE 3) HIGH STRENGTH BOLTS(A325) MAYBE INSTALLED TO A "SNUG" TIGHT CONDITION UNLESS O >O 1S �A-24 INDICATED TO BE PULLY PRE-TENSIONED, (GENERALLY, BEAM CONNECTIONS HAVE BEENlE)JOIST CSIRDER WEB PIODIF)CATIONSDESIGNED d5 SEARING TYPE AND MAY BE INSTALLED TO A "SNUG" TIGHT CONDITION.) �I O N.T.S. R/X4 BTWN 4) PERFORM SHOP AND FIELD WELDING IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY'S u Z WEB MEMBERS STRUCTURAL WELDING CODE. 5) HERDED ANCHOR STUD WELDING MUST CONFORM TO INSTALLATION SPECIFICATIONS PROVIDED BY M 0 THE STUD MANUFACTURER, WELD FIELD TESTING WILL BE PERFORMED. ~r 61 WELDS SHALL NOT BE LESS THAN 3/IS" CONTINUOUS FILLET, UNLESS SHOWN OTHERWISE. CL DETAL N.T.S. G, LIGHT GAGE METAL v J v J 1) STEEL STUDS, JOISTS AND ACCESSORIES SHALL BE SUPPLIED BY A SINGLE MANUFACTURER. \\\ 2) SIZES OF STEEL STUDS ARE INDICATED ON THE DRAWINGS. THE DESIGN INTENT IF FOR THESE ITEMS TO BE ATTACHED TO EACH OTHER AND TO THE SURROUNDING STRUCTURE TO BEHAVE A$ d SYSTEM, WHETHER SHOWN OR NOT, PROVIDE ACCESSORY ITEMS(ANGLES, CLIPS, STIFFENERS, STRAPS, ETC.), DESIGNED BY THE MANUFACTURER, FOR A COMPLETE SYSTEM, 3) STEEL STUDS SHALL BE "C" TYPE. ALL STUOS 6" OR LARGER SHALL HAVE A 1 5/B" FLANGE, PROVIDE CONTINUOUS TRACK TOP AND BOTTOM AND INTERMEDIATE HORIZONTAL BRIDGING FOR tTi STUDS AT 5'-0" MAXIMUM SPACING AND SOLID BLOCKING AS SHOWN. 0-4 4) ALL LIGHT GAGE METAL SHALL BE GALVANIZED. H. SPECIAL INSPECTIONS 1) SPECIAL INSPECTIONS DESCRIBED BELOW WILL BE PERFORMED UNDER SEPARATE CONTRACT BY AGENCIES RETAINED BY THE PROJECT OWNER. CONTRACTOR IS RESPONSIBLE FOR KEEPING THE ARCHITECT 4PPRISED OF WORK PROGRESS AS IT PERTAINS TO SPECIAL INSPECTIONS y AND ENSURING THAT NO WORK REQUIRING SPECIAL INSPECTIONS IS CONCEALED BEFORE SPECIAL 11� INSPECTIONS OCCUR. OTHER INSPECTIONS AND MATERIAL TESTING CONTAINED IN PROJECT SPECIFICATIONS MAY HAVE DIFFERENT REQUIREMENTS, -w REINFORCED CONCRETE: NO SPECIAL INSPECTIONS REQUIRED, WELDING: PERIODIC INSPECTION OF ALL WELDS, A IW EXPANSION AND EPDXY ANCHORES: INSPECTION PER UBC SECTION 1107,5(15). (Yr~A�,ir/•17 W 2, MISCELLANEOUS O Z 1) COORDINATE OPENINGS AND EMBEDDED ITEMS NOTED ON ALL CONSTRUCTION DOCUMENTS WITH Q r � APPROPRIATE TRADES, V 2) CONCRETE MIX DESIGNS MUST BE REVIEWED BY THE ENGINEER BEFORE CONSTRUCTION. 3) CONSTRUCTION LOADS SHALL NOT BE GREATER THAN THE DESIGN LOADS INDICATED IN B,1 UNLESS REVIEWED AND APPROVED BY THE ENGINEER. W 41 TEMPORARILY BRACE THE STRUCTURE TO RESIST ALL LOADS OR COMBINATIONS OF LOADS UNTIL W ALL PERMANENT ELEMENTS ARE IN PLACE AND ALL CONNECTIONS ARE COMPLETE AS SHOWN, r^ V J � w U � w = u wLo Q 00 V V�• 55 Te f ti4.�p15TERp0 Q� A �r ll-�i"OI•tp Sy CPC pT 4kN REED q. CTA JOB NO, DELLCC DRAWN I CHECKED JJK SGR DATE 11/05/01 SHEET TITLE STRUCTURAL NOTES 8 DETAIL S SHEET 19 V 4302 d • NORTii KEY Y I Y Y I R-11 GATT,INSULATION (SOUND)INSULATE WALL TO FULL HEIGHT OF WALL j I I I I EXISTING CONSTRUCTION TO REMAIN cV i. I i I a1 j F'" W.,W I- I i i i j -.-•- PRIVACY CURTAIN V ¢t=Z : j j j I i i I WINDOW BLINDS V V -_-_- -_- - -_-_-_-O ...................... FURNITURE NOT IN CONTRACT USQ z y Z II II I I II II I I I STI m m DATAFIRE WINDOW SYMBOL =QRISERCENTER _ I I I I I B I I I 4I STI I U 31 DOOR 0 -SEE SCHEDULE 61 n5.1 : REVISIONS I IV 4B01 INTERIOR ELEVATION -SEE A001 I I I I ENCLOSED' DOCK = _= I BREAK PL-I DESIGNATES'CHANGE IN FLOOR FINISH i 40 i - -- c-1 PL-I ROOM ROOT"I FINISH LEGEND I 1 I "1 •- I I I VCT FLOOR FINISH CLOSET j i i \ I }I{jat I I o-1 LL WAL FINISH 1FI NOTES i C_1 Fn , WALL FINISH I y I PL-I al / ROOM HUDDLE I 3 -------cowr.EREwcE--- L---- TRAINIWG_---__ --- -•--- - °� ------------- --- B FINISHES LEGEND .......\ j R=OM III RIOOM I'-_ 62 C CARPET _ ST STAINED TILE -- - - - - - - - - - ------- - -�- - ----------J - - - - - - - - . -_-_�_-_-.-.-_ -_-.-_-_-_ _�-_-_-_-_-_-_-..-_ � _-_ -_-_- - - _- _ �--0 ST STAINED CONCRETE , I I G-I cH I I D EX E.ISTING FLOOR FINISH INT OOFr6RENCEI I ROOM 139 HUDDLE a1 al C_, IP STI PV PQNIYL WALLCOYERING I TRAINING IS BASE HALLWAY I I 6I al P-2 Id5 j I j ROOM ROOM u., al JANITOR T TILE-CERAMIC I j C I 1ji> j 32 7H V SS PL PSOLLID SURFACE MATERIAL . C1 ' I G-I P•2 B-1 i 'n PL-2 r W09EN'S FLOOR FIMISdESD al i I' I C-I I u I I ,:a2 SS-I/2 NOTE:CARPET TO BE DIRECT GLUE DOWN PER HUDDLE ❑ NOTE 12 MANUFACTURER'S INSTRUCTIONS I I I ROOM I 61 I II I I _---_-_-.-_ .-_ �j �j Q�Q - NOTE5-_-_-_-.-_-_-.-O C-I FIELD CARPET. MFR:MILLIrN SERIES,QUATTPA 3'X 3'CARPET TILES -I- - �- - I Il ' COLOR TBD rJ NOTE 5 -_ •;B-2 MEWS (RE 'ACCENT CARPET,MFR,MILLN:EN SET 128 (RECEPTION) EERIES:ZEN GARDEµ3'X 3'CARPET TILES PI P-4 P-4 P-t C_1pq COLOR TBD P-2 F 1 P-4 P-4 P-I I I 61 G-3 BORDER CARPET-MLOF2I0 LIKEN I (RECEPTION) COLOR,YT51,"TEMPEST,"3'X 3'CARPET TILEL P•2 P-2 P-2 I I P-2 P-2 P-2 P-1 (CUT TO MAKE 18"BORDER) I I I I P-2 STH COLOR TBD ON-SITE,ALLOW d /SF INSTALLED P-4 EX ExISTINCs FLOOR FINISH TO REMAIN P-2 FAX/COPY VCT TECH $COPY AREAS. MFR.,TARKETT I I I j P 4 121 SERIES:TBD O M P-2 COLOR TBO h LIT I I P-4 VCi BASE FINISHES O M I I j j P-2 a1 61 THROUGHOUT SPACE, W M I I I I P d 3 PE SIZE:4 COVED Us I I I P-1 COLOR:"BLACK" In CD 1 62 TRANSITION STRIP, MFR.:SCHLUTER OR EQUAL Q I I I O (AT STAINED SERE&RONDEC -_-_ _-.-_-_-_-_---_-_-_-_-_-_-_-_-_-_-_-.-.-_ _-_-.-.-.-_-_-_-.-_-.-_-_-.-.-_-_-_-_-. ..-_-_-.-_-_-_-_-.-_-_-_-_-_-_-_-_-_-.. _-_-.---_-_-_-.-.-_-_-_-_-_-_-_-_-_-.- CONCRETE) NUMBERRO-00-AE a FINISH,SATIN ANODIZED ALUMINUM w LL i ' I ALL SURFACES TO BE PL-I, INCLUDING DOORS/ \ WALL FINISHES I O I I I DRAWERS AND EDGES I I I I 10" SPASH, MOUNT OUTLETS HORIZONTALLY PI DARE FELD PAINT. MFRCOLOR EDILL AMB (S-W / LU y IN SPLASH FINISH:SATIN LATEx `F�-'1 ,�I I I P4 ACCENT PANT.INT. MFR,9 W COLOR TBD FALSE PANEL- - - - - MOUNT 3" WIRE FULLS PLACES) FINISH,SATIN LATEx O LW�O -- L HORIZONTALLY N SINK BASE O P-3 ACCENT PAINT. MFR:S-W Q I MEET ADA I FINISH:SATIN LATEx LL (COLUMNS) COLOR TBD - I CRITERIA: SURF ES TO BE PL�1 P-4 ACCENT PAINT. MFR,S-W Q j I j (Z*ZAG) COLOR TBD m= v FINISH:SATIN LATEx r P-5 ExISTIWG PAINT.MFR:BENJAMIN MOORE r^ ,^ COLOR a699 NOT USED FINISH.FLAT ` BRE,[�jK ROOM ELEVATION l L--11 TE H,LAD V-1 BREAK RM. MFR.,JM LYNNE I--1 I 16 SERIES,TRIBU PATTERN 54",TYPE It i I i j COLOR TBD a/1 I I CT-I I I i V-2 REBTROOMB, MFR,J LYNNE SERIES UPBEAT,54",TYPE II V COLOR TBD IT 61 Iy� I I� I I T-I RE STROOMS.70.E DESIGNATED WALLS UP TO 60 AFF AND TOP P-I I I; P-1 I I WITH COVEDF CAP,ALLOW d5.00/SF INSTALLED. P-2 ROOM P-2 I I SERIES: P-4 FAX/COPY -_-_-_-_-_-_---_- COLOR t25--_-_-_- -. - -�4 I -_-_-_-_-_ i. _ _-O GROUT, LAMNATE FINISHES S P-2 - 123 P 4 I I P-4 a, F PLH BREAK RM. MFR,WIL BOCART I I GT-I P-I P-I � � COLOR:TBD i a1 I IbF CT-I C-I F7 PL-2 VARIOUS PLACES,MFR:W0.80NART f/1 I Bi I I I I al COLOR:TBD V J \1 124 3 PL-3 DOOR FINISH, MFR,WILSONART ' I I I ROOM E COLOR, 1054.60,"WILD CHERRY n 1 u I I 122 SS-I BATHROOM COUNTER TOPS,WITH 4"SPLASH SURROUNDS {rYAy'1/ W I I I I C_1 a MFR.:WILSONART SERIES:GIBRALTAR Z al COLOR,OS083-ML,"EVERGLADE MELANGE" O ROOM SS-2 INTEGRATED SINKS (SEE PLUMBING PLAµ BOWL $15"21) Q I I I ROOM MFR:WILSONART V 121 SERIES:GIBRALTAR .• \ COLOR+90T6•SL,"IVORY' I I I I CH GENERAL NOTES.- / al I.PAINTER RESPONSIBLE FOR TOUCH-UPS OF APPURTENANCES TO O LL.1 MATCH ExISTING (CEILING STRUCTURE). I I c I I HUDDLEOO L•�•� 2,CLEAN AND/OR ACID WASH ExIBTING TILE AND GROUT TO LOOK Bi 120 AS NEW AS POSSIBLE, 4,6,T9 I I I I i j C_I PI 3.PROVIDE TRANSITION STRIP AS REQUIRED. � `/ 6I 4,REMOVE ALL ExISTING STAINLESS STEEL WRAPS AROUND BASES V I I I HUDDLE OF COLUMNS(TYPICAL).COLUMNS TO BE PAINTED P-3. W I i TTP,COLUMN-EXPOSED ROOM 119 S.PLUMBER TO GORE HOLES IN SOLIDLU SURFACE PLAN MATERIAL FOR 8"SF=READ OF FAUCET AND LEVERS.SEE PLUMBING PLAN FOR SPEC. �� CAEN%A OFFICE AI A i 4 pj 2 C-I 6.REMOVE ExISTING WALL PANELING AND PATCH AS NECESSARY.PAINT P-I, O W 61 , A50I T,REMOVE ALL EXISTING VINYL WALLCOVERING,DOUBLE HALF-ROUND , ` .•'HUDDLE TRIM,AND PANELING ON WALLS. PATCH AS REQUIRED AND V -.-_ -_-_-__.---_-_-_-_-_-_-_-_-_-_-_---_-_ _-_-_-_-_-_- ----- _-_ -_0-_ -------------------- PAINT AS SCHEDULED, r T S.ALLOW FOR 12"SPLASH AT BREAK ROOM SINK CABINET,THERE I I I WILL BE NO SPLASH AT COUNTER SEATING, ^ I I I I \\ S.KEEP EXISTING DIAMOND MEDALLIONS AND TANCOLORED HALF-ROUNDS NEAR TOPS OF WALLS AS WELL AS LIGHTING SOFFITS,VINYL I I I I I i WALLCOVERING BELOW HALF-ROUND TO BE REMOVED. I I I I I 10.RE-LAMINATE E%ISTING COUNTER TOPS IN OFFICE. w 1 o I I I I I 11,INSTALL 30'H AFF WORK COUNTER AT RECEPTION AREA,COUNTER `M♦ / ` TOP TO BE 24"D WITH NO SPLASH.USE PL-2 FOR TOP AND cc v EDGES.USE PL-2 WRAPPED SUPPORTS FOR BRACING, I I I I 12.INSTALL 42"H COUNTER TOP FOR PHONE BANK,TOP TO BE TEAM I$-D WITH PL-2 TOP,EDGES,AND SUPPORTS. C-I I I i i Roots al 13.INSTALL PLAN EATING COUNTER IN BREAK ROOM,COUNTER TO 2� 0 BE 47'AFF WITH PL-I TOP,EDGES,AND SUPPORTS, NO SPLASH,UNDER COUNTER SUPPORTS TO BE CUT IN SUCH A plil- WAY AS TO NO INTERFERE WITH SEATED DINERS.14.BREAK ROOM SINK CABINET TO BE PL-I WITH 12"SPLASH. tx'.2SINK PORTION OF CARNET TO BE ADA COMPLIANT,SEE ELEVATION THIS PAGE,FOR DESIGµ USE BRUSHEDmmT A50I STAINLESS STEEL OR ALUMINUM 3"WIRE PULLS ON DOORS I I C-I PI TEAM CH AND DRAWERS,ALL MOUNTED HORIZONTALLY. I I I ODMIµ I 3I pI P-I ROOM al F'3IOF AREA I H �P 1 / 110 P-I P-a P-2 O y CTA '$ ARCMTECTS P-4 / _ Aa•180 - - - 1_-_-_-_-. -_--_ _-_-_-_-_-_ -_- -_- - / -O 3 INTERVIEW -_-_ - t P2 -_-_-_-_-.-_-.-_-_ OAVQ L.TF NER V Room I C_1 PI I j j cT L %�����ti��Is '��' P-I al �{{'' S C-1 IO2 I �i PI I TEAM „! JANITOR 3 P 4 P-d n ,,; M 115 ' al 6 III RECEPTION ,------- P-2 P-2 GTA JOB NO. # I Ro INTERVIEW 01 % ....I I II - K ----T------- -- ♦®3 ----- ----------------- -------_---•-- yRorFzvtEtT -------- WAIN -------- -------------------i-_----- ------ ----- / --•-- ---- --PPI --- ODELLGG om P-_2 105 CONFERENCE /wor-mys P-3 DRAWN CHECKED B 1 61 6 INTERVIEW T,9,11 P 2 al iPz FAX/COP7 BCT-I IPI P-2 I 114 _ _ ENTERENSARrN CERooT JJK BH O All L al I 104M - I I• iSTAIR STOR GE '� -_- _-. STAIR -_ - -_- -_ -_-_-_ -_-_-_-_-_-_-_-_-_- P-3 DATE 18"BORDER 108 101 Q M P-3 NOT SHOWN II/0S/01 M CH C-3 SHEET ROO TITLE o 6 i �. I Ex Ex I C_, PI I Ex x Ex x Ex x x Ex x B-I I I Ex Ex al �-O I I I I z x �� TALL SIDE FINISH i I -_-_-_-_-_-_-_-_-_-_-_-_-_-_-.-_-_-_-_//7\ NOT SHOWN E-4 P-4 — — ••---------------■---------------------------•----------------•--------------- ------------- 1�`V/�/ a PLAN SHEET i i I I I I I I , ROOf1 FINISH PLAN D n ASmI Y•.,'� f� NEAR PARKING I 1 1 LJ GARAGE ENTERANCE o ���+o U 2 AXONOMETPICS Alol /". � 5 DI�I � f�1�1 N�fi � �� ecHLE Ln g� STEEL DOORS, N �a INTERIOR:IY4' THICK,GRADE II,HEAVY DUTY, DOOR HARDWARE W , SEAMLESSDOOR SIZE DOOR FRAME REFERENCE NUMBERS CORRESPOND TO HARDWARE LIST IN THE H W MODEL 2, LDRO DESIGN,18 GAUGE THICKNESS W -- MINIMUM,COLD ROLLED STEEL SHEET FACES. SPECIFICATION (SECTION 06110)UNDER CORRESPONDING HEADINGS V ¢I•-Z 4 F GLEAN,PREP,AND PAINT.SURFACES DOOR DOOR LABEL WIDTH HT. THICK FINISH TYPE FINISH HINGE LOCK CYL, PUSH STOP GLOB THREE EMERG MISC. XIT REMARKS Room DOOR • NO. TYPE NESS PULL ER. HOLDS EXITALARM NO. NO, U V 0 • EXTERIOR:1y4"THICK,GRADE II,HEAVY DUTY, 101-1 A 3'0 1'-0' IY4" - 4 12 16 10 34NEW UOOR IN ��I�2 101 01-I Q �W z; MODEL 2,SEAMLESS DESIGN,INSULATED TO XI N W O IN E10 XI ATCH N O ETT V Q R-5 OR BETTER,MINIMUM 16 GAUGE THICKNESS, 101-2 A 3'0 l'0 I j4" 4 12 - 16 19 10 32,34 101 101-2 a2= GALVANIZED STEEL SHEET FACES,CLEAN, PREP,AND'PAINT SURFACES 102-1 B 1 b'-8" 1Y4" PL HM-AL BRUSH I 8 12 - 22 - - - 102 102-I STEEL FRAMES:(FOR STEEL DOORS ONLY) 103-1 B V-0" 6'-8" 1Y4" PL HM-AL BRUSH I 8 12 - 22 - 103 103-1 REVISIONS FULLY WELDED WITH MITERED OR COOPED 104-1 B 3'0 6'-8" I PL HM-AL BRUSH I 8 12 22 AND CONTINUOUSLY WELDED CORNERS �4" 104 104-1 GROUT SOLID,16 GAUGE THICKNESS, 104-2 E 7-0" 7-0' P MFR Ar-f-9t)0 I`Arlh7rME DIVISION 104 104-2 CLEAN,PREP AND PAINT SURFACES. E / E DIVI ION 8 NOTES FOR DOOR SILENCERS: - 105 I B 3'0 6'8" 1Y4" PL HM AL BRUSH I 8 12. 22 34 SPECIFICATIONS ACCESS 105 105-I EXCEPT ON WEATHER STRIPPED FRAMES, 10&1 Iyq" HM-ST P 4 11 - Ib 18 10 28,32 YES PROVIDE A 4"WIDE FRAME 6 DOOR HEAD 106 10&1 DRILL STOPS TO RECEIVE 3 SILENCERS3.34 ON STRIKE JAMBS OF SINGLE DOOR FRAMES. 106-2 D - - - - 11 - YES X N O O DERA N 106 106-2 PLASTER GUARDS; 101-1 B Y-0" 6'-8" I j'4" FIL HM-AL BRUSH I 1 - - 22 - f01 101 I PROVIDE MINIMUM 0.0119 INCH THICK STEEL 3'-0' 6'-8" I MGM I 1 - 22 PLASTER GUARDS OR MORTAR BOXES AT BACK 108-I B y4" PL HM-AL _ 108 108-1 OF HARDWARE CUTOUTS WHERE MORTAR OR 111-1 B - Y-O' 6'-8" 1y," PL HM-AL BRUSH 1 1 22 III 111-I OTHER MATERIALS MIGHT OBSTRUCT HARDWARE OPERATION, 112-1 D - IY4" - EXISTING DOOR TO REMAIN 112 112-1 FLUSH WOOD DOORS; 113-1 D Iyq" - II - YES EXISTING O REMAIN.DOOR TO 113 113-1 SOLID CORE WOOD DOORS f-LD-2 PARTICLE RECEIVE NEW CY�R 4ALARM BOARD WHERE NON-RATED OR 20 MIN RATED. 114-1 D IY4" - - EXISTING DOOR TO REMAIN 114 114-1 -MINERAL CORE WOOD DOORS WHERE RATED 115-I B 3'0' 6'8" I PL HM AL BRUSH I 9 12 25 45,60,OR 90 MIN,FIRE RATING, y4" - 115 115-1 -PLASTIC LAMINATED EXPOSED SURFACES b I B 3' 6'8" I BRU SH I 1 22 20,45,60 AND 90 MINUTE DOORS TO BE Ii0' yq,: PL HM-AL 116 116-1 CATEGORY "A"POSITIVE PRESSURE RATED WITH II1-1 B - 3'-0' 6'-8" 1Y'4" PL HM-AL BRUSH I 1 22 IIl 111-I CATEGORY "H"SMOKE AND DRAFT RATING WITH THE 'IS"EMBEDDED INTO THE LABEL 118-1 B Y-O' 6'-8" 1y4" PL HM-AL BRUSH 1 1 22 - - 118 118-1 BOND STILES AND RAILS TO THE CORE, ABRASIVE'SAND CORE ASSEMBLY TO ACHIEVE 119-I B - 3'-0' 6'-8" 1y4" PL HM-AL BRUSH I 1 - 22 - US 119-1 UNIFORM THICKNESS, 120-1 B 3'-0' 6'-8" 1Y4" PL HM-AL BRUSH I -122 - 120 120I ALUMINUM FRAMES FOR ALL FLUSH WOOD DOORS d SIDE LIGHTS 121-1 B Y-O' 6'-8" I PL HM-AL BRUSH 1 1 22 BRUSHED ALUMINUM FRAMES _ �4" - - - - - - 121 121-I MANUFACTURER: RACO 122 I B - 3'0' 6'8" 1Y4" PL HM AL BRUSH I 1 22 TEL.219-234-1151 122 122-1 FAX 800-122-6462 124-1 C 60 MIN Y-O' 6'-8" 1 y4" P HM-ST P 4 6 12 16 34 124 124-1 (`J� ALUMINUM WINDOWS AND STOREFRONTS s ENTRY 125-f IS 3'0' 6'-8" I�4" PL HM-AL BRUSH I 1 - 22 125 125I KAWNEER BRAND DARK ANODIZED FRAME (SIZE TO MATCH EXISTING) 126-1 B Y-0' &-8" 1y4" PL HM-AL BRUSH 4 6 I2 - - 16 34 - 126 126-1 WITH 0,0818 MIN OR THICKER FINISH -ALUMINUM FRAMES FOR ALL FLUSH WOOD DOORS 128-1 B 3'-0' 6•-8" 1y4" PL HM-AL BRUSH 2 14 22 16 - 128 128-I 129-1 B 3'-0' V-8" Ij'4" PL HM-AL BRUSH 2 14 22 f6 - - 12S 12S-I GLAZING 130-1 C 3'-0' 1'-0" I P HM-ST P 2 11 - 16 19 I0 29,32 YES PROVIDE 4"WIDE FRAME 9 DOOR HEAD 130 130-1 EXTERIOR GLAZING:(FOR EXISTING AND NEW GLAZING) �4" _ INSULATED GLASS WITH DARK GRAY 131-1 B - Y-0' I ' PL HM-AL BRUSH 1 9 12 W 0 M TINT.CLASS 2 (TINTED,HEAT ABSORBING AND 6'-8" �d 131 131-I L LIGHT REDUCING) 132-1 B Y-O' 6'-8" Ij'4" PL HM-AL BRUSH 1 1 9 12 25 132 132-1 l y_O ADD TINTED FILM TO EXISTING GLAZING INTERIOR GLAZING:(FOR NEW GLAZING) 133-1 B 3'-0' 6'-8" 1Y4" PL HM-AL BRUSH I 1 - - 23 - 133 133-1 CLASS I(CLEAR)FLOAT GLASS,ANNEALED, m!$ KIND HS (HEAT STRENGTHED) 134-1 B 3'-0' 6'-8" IY'4" PL HM•AL BRUSH I 1 - 25 - 134 134-1 w LL BUTTS 4 HINGES: 135-1 B 3.-0. 6'8" 1y4" PL HM-AL BRUSH I 1 - 23 - 135 135-1 U I O 3 HINGES PER LEAF TO 1 FOOT 6 INCHES HEIGHT - 3'0' 6'8" I BRuBH I 1 -- 11 - - -CONCEALED BALL BEARINGS 5 KNUCKLE HINGES 135 2 B Y4:: PL HM-AL 135 135-2 -EXTERIOR HINGES SHALL BE STAINLESS STEEL 136-1 B - Y-0' 6'-8" IY4" PL HM-AL BRUSH I 1 - 22 136 136I ru WITH NON-REMOVABLE D E PINS -SOME HINGES HAVE AND ELECTRIC STRIKE. 131-I B - 3'-0' 6'-8" Iya" PL HM-AL BRUSH I 1 - - 22 - - - - - - 131 131-I to M COORDINATE WITH CM AND ELECTRICAL CONTRACTOR, 138-1 B Y-0 6'-8" I%4" PL HM-AL BRUSH I 1 - 22 - - - 138 138-1 m INTERIOR HINGES HALL HAVE NON-RISING PINS O O FINISH SHALL BE SATIN CHROME 140-1 C 3'-6' 6'-8" 1Y4" P HM-ST P 1 II 25 - 10 140 140-1 0 MANUFACTURES-HAGER STANLEY OR MCKINNEY a ^ oC •• MANUFACTURER FOR ELECTRIC STRIKE-VON DUPRIN 140 2 B - 3'0' 6'8" I jq" PL _ P 2 If - 16 - 10 32 XI N A N. A O 140 140-2 /•� I� (7 Z KEYING: 141 I G MI 3'6' 6'-8" ij/4" P HM ST P 4 6 .12 - 22 16 34 141 141-1 �L,4 0­4In 0 -CYLINDRICAL LOCKSETS SHELL BE THE BEST LOCK 142 I C MI 3'0' 6'-8" 1�4" P HM ST P 4 6 12 22 IS 34 142 142-I ^R- MASTER KEY SYSTEM, -COORDINATE KEYING WITH OWNER AND 143 I B Y-O' b'-8" 1y4" PL HM AL BRUSH I 1 - - 23 143 143-1 CONSTRUCTION MANAGER LOCKS: 144-1 B 3'-0' 6'-8" Ij'4" PL HM-AL BRUSH I 1 - - 22 144 144-1 -HEAVY DUTY CYLINDRICAL LOCKS 145-1 B 3'-0' 6-8" 1Y4" PL HM-AL BRUSH - 1 - 23 - - 145 145-1 -STEEL CHASSIS '145-2 B Y-O 6'-8" I3/ PL HM-AL BRUSH I 1 22 -ZINC AND DICHROMATE PLATED FOR RUST /q" - - - 145 145-2 RESISTANCE LATCH BOLT MINIMUM THROW ORylg" EXISTING DOOR TO REMAIN ~~ EFFECTIVE DEADLOCKING THROW 0; 201-1 D - 4 6 12 34 201 201.1 NYLON INSERT FOR EASY DOOR CLOSING G -REGULAR BACKSET OR 2Y4"MINIMUM WITH 2O3-1 D - - 12 EXISTING DOOR TO REMAIN 203 203-1 0 GREATER BACKSETS AVAILABLE EXI TINT DOOR TO REMAIN 203 203 2 ~ -LEVER TRIM LOCK SETS ARE THROUGH-BOLTED 203-2 D - - 12 r , 2 TRIM AND EACH LEVER SHALL HAVE 203 203-3 V F/ INDEPENDENT RETURN SPRINGS. 203-3 D - - 12 XI N R O R M 12 1�1 RPrEIVE NEW CYLINDER MANUFACTURER:BEST EXISTING 203-4 D 13 DOOR TO REMAIN, 203 203-4 - - - EXIT DEVICES: EXISTING DOOR TOIVr REMNEWAIN, SURFACE APPLIED RIM-99CH EXIT SERIES 203 5 D - - 12DOOR TO RECE V) 203 203-5 LEVER HANDLE TRIM 990TP MANUFACTURER-VON DUPRIN L.L CLOSERS: W FULL RACK AND PINION TYPE WITH REMOVABLE W NON-FERROUS COVER PROVIDE SEX BOLTS AT ALL WOOD DOORS, Z PLACE CLOSERS INSIDE BUILDING (PARALLEL ARM TYPE) O -NON-HANDED,NON-SITE AND ADJUSTABLE -EXTERIOR DOORS TO HAVE 8,5 LBS MAXIMUM v Z PRESSURE TO OPEN INTERIOR NON-RATED TO HAVE 5 LBS MAXIMUM PRESSURE TO OPEN / INTERIOR RATED TO HAVE 12 LBS MAXIMUM O W PRESSURE TO OPEN DOOR TYPES WINDOW TYPES W-MANUFACTURER-LCN,DORMA TRIM AND PLATES -PUSH PLATES SHALL BE 4"XI6"I6 GAUGE, 23-4" rVl -PULL PLATES SHALL E 4" CLE4R/TINTED B XI6"I& GAUGE PULL SIZE SIC TO C,PROJECTION Il�g", TEMPERED CONTRACTOR TO FIELD VERIFY (STING CLEAR GLASS ^G% 88 TYP PROVIDE GLASS ' 1 � -KICKPLATES 8'X1�2°LDW,THICKNESS 0.050. �TNKBTOREFRON TINTED a �4 MANUFACTURES-BALDWIN,IVES,TRIMCO. ..........................._...___.........--..-.._..............._..._.__._.................._...........,........._......._......._._...-_.......;.......-.... _ I..f ....................................._....;.._................-..._,:...f..... .....................!.........................�f.....,............... ,...a I— STOPS 4 HOLDERS: 4RK / `� -ALL HOLDERS,FLUSH BOLTS AND STOPS BY ONE S ODIZED SOLID CORE -----H.n, EXISTING MANUFACTURER NO PLASTIC COMPONENTS IN ANu WITH PLASTIC SEE SEE STEEL ( ' OVERHEAD STOPS VENEER W REMOVE EX18iNKT DOORS!CND HAIR LAMINATE SCHEDULE SCHE VEEE AND PR6VIDE',NEW STOREFRONT DARK LE ACCESS I U STOPS SHALL BE SUPPLIED FOR ALL DOORS, NEER PANEL ANODIZED WITH DARK GRAY TINT. I O -THEY SHALL CONTROL THE DESIRED LIMIT OF OPENING HELPING TO PREVENT DAMAGE II !! TO ADJACENT WALLS,COLUMNS,EQUIPMENT, II �1 CL4 THE DOOR OR ITS HARDWARE, O © ® (D MANUFACTURER GLYNN JOHNSON IVES i.........:......................__._........__.a.................:........: ._.....!1.........................._.1�....._............._..._i!................:._.... ACCESS PANELS: 4 ii% r 4 r 4 /..!I )..........._ �I 4 T ,^ SIZE:24"X24" I........................!.__.........................Y.......................,.`F.,........_....._.............._.............. L•� ��uyy'J�� CEILING OPENING:24y4"X24)4" I ......................... ....�f.I ..................._...._..._'�..I iI t Q CC U / _ OUTSIDE DIMENSION 6"X2& I ! I I REMOVE INSIDE DIMENSION:24"X24" I Ex1sTING MANUFACTURER:LARSEN HARDWARE GROUPS I; I DOOR AND !I- MODE / PROVIDE L:L-DWG / / �` I FRAME:!& GUUGE COLD ROLLED STEEL I / y ' 6 NEW DARK PAW51-06 GUUGE COLD ROLLED STEEL �� �• - ANODIZED •- HINGE:CONCEALED PIN TYPE L......................) ! r !1 STOREFRONT ABBREVIATIONS: PUSH/PULL ! t::::`::::::::::::.! DOOR WITH •• LATCH:FLUSH SCREWDRIVER CAM / ( GRAY FINISH:PHOSPHATE DIPPED GRAY ALUM ALUMINUM 4,PUSH PLATE:IVES SERIES 8200 4XI6 B26D I // /� I // I / ! DARK PRIMED (READY TO PAINT- MTL METAL PULL PLATMIVEg ggERIE9 5302.9 AXlb !--------- -• -I TNT . Q� HM-AL HOLLOW METAL-ALUMINUM PULL a8102-8 B26D - �..._..:..... 1......__.__._...-..._._.....„....„...„„!.--._.! ....._._..._. �.........__._._....... ..._....... PAINT TO MATCH CEILING) HM-ST HOLLOW METAL-STEEL ^ DIRGE READER LID WOOD CLOSER L� T TEMPERED EXISTING TEMPERED GLASS W WIRE 16, LCN 4110 SERIES MODEL 4111 q-g• S STAIN GLAS9 CP•gE OF /O P PAINT,RE:AFIV 11. LCN 4110 SERIES MODEL 411t W/GUSH MAX EXISTING CLEAR 3'-3" I'•4" '4" .`��.i�' LB LIGHT BRONZE OPHNING 90' CONTRACTOR TO FIELD VERIFY GLASS TYP. 1 � y AF2CHITECTS O CTA 08 DARK BROWN AR-1803 PL PLASTIC LAMINATE,RE:A501 THREBFIOLD - - e BRUSH BRUSHED ALUMINUM r DAVID L.TURN" H 16.MAWR 4226-A 12 TEK SCREWS ,--:;:-:-:-..::-:--::„:•.:•-•:•.::......••;-::.......,-_._.._...;_:_._...:. 8EE DOOR ALUMINUM FRAME, P�1' S• 6 HINGE I 19.HAGER 422E-A 36 TEK SCREWS (�� l�i� .. iif i! I SCHEDULE ` ,/ SEE DIVISION 8 T'�i 0:STEa� ;�u,Q- I. HAGER 1219 4y2XAY X652 ' ALUMINUM FRAME, `' NOTES O ,% I I STOPMOLD REMOVE E)&TNO, II '! 2. HAGER B151219 4y2X4y2X6S2 j! ! SEE DIVISIONS T p, , I 22.WALL STOR IVES NO.d08'2 B26D DOOM AND!!HARDW4RE '! ! ( NOTES T : GL4ZION SEE 3• HAGER 881219 5Xd/2 X652 � AND!PROVIDE ! DIVISION 8 4. U)MCKINNEY GONG�LE ELETRIC HINGE-CC OPTION 23,ROLLER BUMPER IVES NO,412 8260 NEW jOTOREO.RONT ! Ii p TEMPERED GLASS NOTES q (2)HAGER BB1219 d�2Xdq/2 X652 DARK! ANODIZED !, �I �" BEE DIVISION 8 `g 6 CTA JOB NO. 24.FLOOR STOP:IVES NO. B26D WITH ICLEAR!GLAZN3 I ! NOTES i T` g- !! II LAN. 25.HEAVY DUTY WALL DOOR STOP 4 HOLDER:IVES NO.445 B26D II II • 6, BEST 93K1 OEL114 CSTK 626 ( '/:I , ,. 1TI DELLCC 9 1. BEST 93K1 N 14C STK 626 WE4THER8TRIPPING 1..............iL._......_............_.!L._...._..........._.........._.( ......_..11.W.........._......__.....__._._....._......!.._...... DRAWN CHECKED ` 8, BEST 93K1 R 14C STK 626 28.HAGER 8915-A-N 12X84 TEK SCREWS i` / iti I F- S. BEST S3K1 D 14C STK 626 29,HAGER 8915-A-N 36X84 TEK SCREWS ! 1�" I JJK BH I r_ ! .....__._.........._.......................__......! 1 5'i DATE -`+ EMERGENCY EXIT DEVICES MISCELLANEOUS i CONTRACTOR ITO"FIELD VERIFY 11/05/01 $ 10.VON DUPRIN CX99 990TP 626 32.SWEEPS-HAGER 1565-d-V 36 TEK SCREWS N PER DOOR LEAP i 33.ASTRAGALS-HAGER 8315-A-N 84 TEK SCREWS I ! EXISTING CLEAR SHEET TITLE CYLINDER 34.ELECTRIC STRIKES:VON DUPRIN SERIES 6000 (STRIKE FORCE) II i / ,I GLASS TYP, 1! ! f` !I //'` --I� DOOR IL BEST IE RIM CYLINDER 626TO. !� _I I (SALVAGE I ! II I } SCHEDULE/ 12. BEST INTERCHANGEABLE 1 PIN CORE TO MATCH I --••- WINDOW KEYING REQUIREMENTS i `� i !I WRING II { ' W w WALL DEMO- :' -.-../ ` BELOW AND ii 'm 1'.. .......! !_.........yf REINSTALL) it ( l 7. -" ®. '.......... ........__......__. ......_..._:. II II I II TYPES 4 VIEW FRon READER ! T E 7777 !i I, SHEET RHCEPTION,AREA REMOVE EXISTING DOORS II NEW STOREFRONT DARK 11..-.............._....._....II.._......_......_._. .It..._____....._._..._!..._..._........._._:.F.....,- ..........._.-... ..-__._.._..__......._....-...... AND HARDWARE AND PROVIDE 11 �/ ,r/!! aANODIZED WITH CLEAR GLAZING, ® ,W-0TO ,( ��+ FINISH FLOOR 7//0\\{ I a ` v W LLHy-1 I I j I � I I I I j e�V�' �=Z U��•2 i i i 0 i i REFLECTED CEILING PLAN KEY O Q LLuu yz� EXISTING 2'X4'ACOUSTICAL TILE CEILING m= V I I I I I I ) I REVISIONS AC NEW 2'X4'ACOUSTICdL TILE CEILING _ I I I I I nh4 T EXISTING GYP.BD.CEILINWSOFFIT E-CsYP c a�iIj ll.....`...Ji;i!iIlii'i'!............._....•..l1:I!I�:II..........._�l,II,IIIIIlIII1II�ii;iijjIiiilIIIjl llllIll'iIL1tlIII',ll__._.._._._�..i�i:I�iI,III�_...._'...(S-._...'7.t_._...-l:'li�I'I__.7"I�.__1{III�IiI;_..t..lI,WIIjII11IIIIILI',I��IlIIIII�1pII�Il1I,IIII1III1I',I1I........-.........._..._....I.1I jIl��I,1!i.._........+,���1iI!II,I;iI.FS!F1�,P.T,IIIII,I,','I1iI,,'11IIIIiI�II''II ___=___________(�_=___'=____-=____-==___-=1=____LLtLLLL-L'-_=-__---__=-__-_-__-=1-__-_-__=-__-_-se_-_,-__-__.-A,__--__-__--=__1-__-__1LLL_LLL-=-_--__-__f`-°-_==_-__-�_�--=_1=_-_�_-_i=-_-=_-__'-_1--=-_=-__-_--_=-_-__-__-_=--__-__'11111t1 'i , .:�•..•.."_Lrr_S_.1....______.....#__.__,?....._=__._....Z_=:}__-i;...._=.1___...C..��_.=_-_-rL._-"___-__._".-1LLLLL.I.''._=.=._.__-__.i.=_=�s__-:_jI.u.�__==-__-_..�__=__-_-.."I_._�=�______'d..._=__■�__..-'�_=__-_I LLLLTjiiI�=.___-,___-_.JE____-__=2__-�__!r'_•_C____-_la-_-_-__-___--__, s`__•____=3__=______i__=___Z—Y=__=____ _✓___"-LLLLI=____-____•I_3_____=____-f�fi!!III!II;I...=__0..__�_."'=�__-{�;.0 4..LLL._....;7__.___�.�o.__=___•_1_�+___}�-y•"______•"1___}___��b—..—____•___.�..�a...___.__'TI,.`.LLL L.1....�.____�_'..-.=_.___-...-..�_==..�T}T}_L. ,_=__--=_{1\L tLLL_=—=___-__=/r'-__=-_=___=-i_=_!II'_=-=___---_-_=___—•�f1'1'-;IF�IIiII,I!I,III1II I /I ,. 'LLLLL.�•-."{:`_=__"'`-. _=--�_=_=--i_>=__"��_=-_'—�=:�-=_=_-�--''"LLLLLLL�---__a-_________-__-\—__-_____-�-�___=•_-[_�m 0=__—��___-_--``=-.��YQ>YCfjIIII,IIIIIamIiIII(! >•LLLtL—==__=-__=__==__• =_=•___v•—_==i___--tLLLL•__=_-__-__=__-_____=-__-_-:__1__-__:=__=`___;-:=_=E-___::==_•___'i;-�LLLL-•\�.:._=.__......-�r=____. p� =__-';_-_=�'_.•; '�2�LtLG:__,'•'.,—'_�=_�_:-.;::.+'_J=_w��'{-:=:a_:•_- •\==:t`_:'..'-==:�'`:-�'==:_:i:=s=_.:`111..t '{�,--''°/•--m 3•'-m-'-------------- — — OO 32 C,.sYP MECCEHLA N ICA L mw %,,G YP. B .c r L IE WL E SCO TRFF IC I T EXPOSED TO STRUCTURE ABOVEEXP_ ---- -- ------------------- L ...._.... 0 SEE MECHANICAL SEE ELECTRI CAL c 2 REFLECTED CEILING LEGEND , iL 0 0 , , 7 CEILING MATERIAL NG HEIGHT NOTES REFLECTED CEILING LEGEND NO TES IT I. VERIFY EXISTING CEILING HEIGHTS.Ir ' G1' 2. ALIGN W/ADJACENT CELING HEIGHT.� � 7 -Gy . .sA A ---- --- SA 5• JL......1..............{..... i_L I_J. I GENERAL NOTESj _ — I. SEE EXISTING MECHANICAL AN ELECTRICAL DRAWINGS FOR ADDDITIONdL .........i.._.W_ M._ CELING INFORMATION. .b.......i......1...... .......... ...... I sA s5A SA 7 UJ iL KEYNOTES O O���FFFF�rrrT---NNrV�t iWt�Om{LF��O./-JYI�Y z 20 .... I I. MODIFY EXISTINGEXISTING NEEDED MAINTAIN THE 2X4 GRID WHEN"NO THE NEW ACOUSTICAL TILE INTO THE EXSTINGGRID..1�IA PROVIDE NEW WALL ANGLS 6MODIFY GRID ITILEB FOR NEW SPACES ADDED. INFILL WITH %"GYP.BD.CEILING,ALIGN WITH ADJACENT........�.. I SOFFR/CELMG FINISH...._. _ A , sA A. ALIGN NEW GRID WITH EXISTING BOFFR,RE: S. EXISTING SKYLGHT.COVER INSIDE SURFACE W/ OUTWATER PLASTICS SMOKED SHEET OF ICE 33MM THICK 6, SUSPENDED WALL ALIGN WITH SOFFIT HEGHT 1, PAINTING CONTRACTOR TO PAINT NEW EXPOSED DUCT WORK AND C COMMIT THROUGHOUT TO MATCH EXISTING.TOUCH UP EXISTING EXPOSED DUCT WORK WHERE REQUIREDREMECHANCAL S, ACCESS PANEL,RE,A60 DOOR I104.2 4RE,A301-11 - _- _ _ __ _ __ _ _-- _ _ _ C_ _ _-- _ _ __ _ AC 1 vv 0NY$MON��wOj.' anaroLe"oy ........_.-......I�',i11Iii)1!Il.........................___.........i.j'JJIWlI,I11IIII1,II,1i;;I;NIl I!j;11lIII1LIII1lIIl1.I1.._1I...fIj;-.._......_-..._.jiIIII1I'Ii�I-..„.....„_....:."-:...._.".{:ii.�.II,�'C-'.•.�___.•.-.,__...11•.��;1,-_.'_S._...t...:___.!1j,IIIiIjVVI{IIIy 7ll:III!1'I�-1l1I1lII�I1IIIILI1I./................r1l{,Iji...._......,l�iIliII I`,�l�€'I�'rr III�,I1'"{FI!.'II,,I1 N ___III_IIUiIIWIIII IIlIilIIl II __j1I!i,E;l ii,IIi___3_53--.'_.__.•._-.'}.d______J tti_______LL___________-______-____11___5s___A-- -..___..I,�..s_.._-__._____.}�.________L_._am._/___-_..,Z_LL-_t-.__...__=_._____..__-../.....�_A___.1._.GZ•m_-.____.iLII..-Y-.-LL._--:____. LL_--�_4_=_-_--�_=_-____'_-__-____-L-LLLL__�-__--___---______--______LL____-\_-_____-_-____-■I_-__-__-L_-LL.__—.---______--_-___---____-,�-LL__-_-_-'!�°-_____.-.d ILI _--___-r -G__----�C,-_-_-=^�-__=-_•s•-,LL_L__d..__-,_A-�,.:-.__-_-_...-.__-___..-.rLL_-_.�1i16IIS�I!II�1Ij I1I�V.•,-==___-,.w°-=__.i.�.->LL.__•._= •._-__-'l y.�,-__=__A.'.�_-_.C_-'.LL.--\.-._� L.I.•>■-=_._-Y-__L_i-I y7LL1__•� L__-'_.____I_•'�_=__-��LL�IrIIIiIII'IIIIir'i.L.—LLL_:_.-_-_____.,.. _-____2=_-___II LL_--____-____7_!-_-,-_�__._@..—�_--____-0LLLL___-___________---____-_^-LL_-__�_,____>______'�_____-.��i�i1y-I1I,IiIIIIIIII♦i1II __--___-•:_-____,_-,LL-__-_-'_-.___-_--_____-_--_____-_-LLLLL__V_-____,-,_-___._-':r-______--LL-_-__-1�5-_____-4 _____---____—__--•LLLL__G-jE J____l_-_-s_______-.Y.______ _-- ,`_�.___!.iIl!•I= �,'___I..C.Il1,1II___1..l,•.•l�:-.7_._•._/,..:I-,.I11.I �~. .--•�l•,{�IIv ISI,A1 A02m 00 ' -O000�S" {' C!m11�SV T5�1.E •/m l ; rW s5A d A ______L L _____} v�W L.......... ....... ....................................... 14 .....�...._.It..._.L.............i• l5 ssd AG .............. — — — — —__-_-_-_-_ -------"-------- -----" ..._I............I..._..i...... Lo .... Ij i IT: .j j. Fl 4 i .11-------L .......... 1-o 7 sJ TA 180.3 A10 ll' AG _ _FLIT:I __ ._._........... ..:.......__-_............................_...................: ......d.......1 _ . . _ J 4 + ° 4 CTAJOB NO. :............... ..... . ..............L............... ---- -- ..lr .._ — I .._........... a . _— — — — — G----- -- DELLC_ ....... -: ..._._...... 0 T' ---------- DRAWN CHECKED E D TT TTT ii DATE............_. P ._. . _-_-_-_-_ TITL SHEET ....._..... . — REFLECTED CEILING �AC PLAN ------ ----•----------- -------------- --- ----------------------------------------------"----------------------------- - SHEET---------- IN Ip] - REFLECTED CEILING PLAN A i �, NortrN 2"VENT(N) i. PLUMBING SPECIFICATIONS cw �I PLUN51NG FIXTURE SCHEDULE (EI CONNECT (N)TO (E) (,/) ?W 4"WCO(N) MANUFACTURE TRIM CONNECTIONS NOTES DIVISION 15 GENERAL CONNECT I I SYMBOL DESCRIPTION ]C N o tt REFERENCE Q� (N)TO (E) 2" 2/2 <NI REPLACES (E) '.' I II � 2"VENT(N) & CATALOG HW CW W V LL—y I REGULATORY REQUIREMENTS,GENERAL = ly W TRAP PRIMER W/ (N) 2 „ I TOILET AMERICAN CHURCH 5321.112 1.6 GALLON/FLUSH, g y i P pP 9 Comply V �N ACCESS PANEL 2" G� 1%2" Cw(N) 2 %z"VENT(N) .'I I i : I i P-1 STANDARD SLOAN ROYAL 1 1/2 4 2 FLUSH VALVE FLOOR Construct following)building modified sby the dotal jurisdiction:ll a 1'coble local building codes,latest edition. Coin I I_"Z U (a P-1 i �,� P-1 .� I i NOTE 1 2234.015 Ill MOUNTED Uniform Building Code - 1997. CIC U=(J �4� I I I 2"VENT(N) - Uniform Plumbing Code - 2000. U• vo Q TOILET AMERICAN CHURCH 5321.112 1.6 GALLON/FLUSH, Uniform Mecha icalC - 1997. 2"(E) �(E) IN .i ( } P-1 .' i ' IY�3"WCO(N) P-2 HANDICAP STANDARD SLOAN ROYAL 11/2 a 2 FLUSH VALVE FLOOR Uniform Fire Code -�997. 97 O Q W I I i (.Ip� '' I i I / �I 3043.102 ttt MOUNTED - tional Electric Code - 1999. U G P-2 1 0� 21/2"(N)REPLACES (E) \ P-8 I J V J '.i i .' i ' R-4 In tional Ele comply with the following w, m m= P-8 11/i. O \ 1 3"VTR , " I i I URINAL AMERICAN SLOAN ROYAL 186 1.0 GALLON/FLUSH.; r P 1 �,,,, SHUT-OFF 2" \ ' �. `(N) P-5 ' P-4 .'� I I I P-3 STANDARD 1 2 11/2 ADA MOUNTING The latest version of the Americans with Disabilities Act Guidelines and the Uniform Federal Accessibility i i/z VALVE CONNECT \ 4"WASTE(N) ♦ ,)/fir// '� r r i 4"WCO(N) 6541.132 HEIGHT Standard,whichever is more stringent. J P-1 P 5 <N)TO (E) L2"VENT(N) P-4 ' I r I All applicable Local.State and Federal laws. 11 4"WASTE(E) \ i BY OTHERS PdJ STD FAUCET POP-UP DRAIN Obtain required permits,plan review and inspections from authorities having jurisdiction. REVISIONS /z, P 1 O I C f) /y"VENT(N) LAVATORY CONNECT vf( / ( P-4 �b� p_2 P•4 LAVATORY WRIST 72 1/2 1/2 2 11/2 INSULATE P-TRAP, (N>TO (E> Yi(E I (tJ) I/2" \ �� P-1 �� �'� I I �.'�� WRIST BLADE RISERS AND STOPS, BASIC MECHANICAL REQUIREMENTS N 1/2' N 3"VENT(N) >. PROVIDE LEONARD 'CW TO G CONNECT . P-4 r yI P_7 GENERAL P-1 /2 P-4 7�2" 2„(E) (N)TO (E) �� 2"VENT(N) ��I I COUNTERTOP MODEL 270 MIXING FLOOR DRAIN ��. I DRILLED BY VALVE UNDER LAV, Sco e: P 1 P_4 I IIIA �` 3"WASTE(NI I ( .. P PLMB CONTRACTOR SET AT 110'F The Contractor shall,install and coordinate all plumbing work to provide complete and operational plumbing 0) I P 1 installations. 1"(E) SIN P-4 P-2 �� .�� P-3 p-3 JR SMITH 6"ROUND TOP PROVIDE TRAP PRIMER Supply and inst llcomplete plumbinglsystems throughout to complete project for plumbing systems described SHUT-OFF I�z P-4 P-1 - CONNECT \ �� P-5 p-5 FLOOR DRAIN 2005-A-PO50 2 11/2 herein and indicated on drawings. 0rowings are in-part diagrammatic. VALVE(N) 1"(N) �i" (N)TO (E) v 3"WCO(N) 3"WCO(N P-4 CONNECT I� . �.1 Plumbing Performance Requirements: _ �� P 1 TRAP PRIMER W/ IN)TO (E) �� P 3 SERVICE KOHLER CHICAGO FAUCET K-8940 RIM GUARD,MOP Provide components and installation capable of producing n system s with the following minimum Working- TRAP ;r4,. ACCESS PANEL �� P-6 SINK K-6710 897 3/4 3/4 3 2 HOOKS,HOSE & WALL D 9 a p 9 piping 9 9 3"WCO(N) HOOKS ressure ratings,unless otherwise indicated: O P-3 P 3 FLOOR GRAIN , am tic Water Piping 10- ppsig O P-7 K ELEC WATER OASIS FINISH:STAINLESS Sanitary Waste and Vent Pipingg 10-foot head of water P-3 3'WASTE(N) � 1/5HP,120V.LOWER SPOU Storm Drainage Piping 10.-foot head of water. "WASTE(N) P-7 COOLER P8AMSL STEEL 1/2 2 1 1/2 36",UPPER 42"ABV.FIN P"3 FLR. Ptumbin Desi n Re uirements:Comply with the requirements of the following authorities having jurisdiction: P-5 CONNECT �'�l �-4"FCO(E) Y g g y HI-LOW City of Twin Falls,Idaho. (N)TO (E) 4"WASTE(E) SINK ELKAY AM STD FAUCET BASKET STRAINERS Intermountain Gas. P 7 P-8 SINGLE BOWL LR-2521 7230.372 1/2 1/2 2 11/2 PROVIDE LEONARD WRIST BLADE MODEL 210 MIXING Insulate the following piping systems: VALVE UNDER SINK Above grade domestic cold water,hot water and circulating hot water,1"pre-formed fiberglass with while all SET AT 1101F service "ocket,PVC fitting covers. Storm rain and overflow storm drain including the roof drain bowls,1"pre-formed fiberglass with white all service DOMESTIC WATER ISOMETRIC DWV ISOMETRIC O ICE MAKER GUY GRAY FINISH:GALV 24"ABOVE FINISHED acket,PVC fitting covers. 1 2 p'9 BOX EUYBIM8 G STEEL 1/2 FLOOR urribing vents with-in 4'-0"of vent-thru-roof. 1"pre-formed fiberglass with white all service jacket,PVC fitting P101 NOT TO SCALE P101 NOT TO SCALE covers. EXECUTION Provide structuralwork and equipment as required.to control expansion and contraction of piping. Verify that all anchors,guides,and expansion joints provided adequately protect system. NOTE 1-CONTRACTOR'S OPTION TO REUSE WATER CLOSET REMOVED FROM PHARMACY AS ONE FIXTURE Install eall quipment, accessories a and specialties according to manufacturer's written instructions. Install equipment,accessories and specialties s provide access for periodic maintenance,cleaning and servicing. 1 I/y"HW (E)TO BUILDING Insulate)and coverollydeso'i.gelland water supolrts affixed piping located underlavatories and sinks. TIME CLOCK FOR REJAM -- I/?'HWR (E) n traffic areas of finished gcorridors. pp p g Extend cleanouts to finished floor or wall sur ace.Install chrome plated round cover. Do not install floor cleanouts PUMP SET FOR 5:0RECIRC 11/2"CW (E) Installwater hammer arrestors complete with accessible isolation volve on hot and cold Water supply piping to ON & 3:00 AM OFFPUMP (E) lavatories,sinks,and appliance outlets. COPPER CONDENSATE DRAIN LINE Test installed fixtures after water systems are ressurized for proper operation. Replace malfunctioning fixtures and CHECK FULL SIZE FROM AC UNIT W/ TRAP gg p EXPANSION TANK (E Clean fixtures, faucets and of installedfitting fwith manufacturer's operate properly. J^' Clean fixtures,faucets and other fittings with manufacturer's recommended cleaning methods and materials. V VALVE (E) CONNECT (N>TO tE) P 9 s. Dr not allow use of fixtures•for temporary facilities unless approved in writing by Owner. GATE VALVE (E) V AIR GAP Interior Coordination The ceiling space shollbe layered With a sprinkler piping•zone near the underside of the structure,with the HVAC duct zone immediately below,HVAC and plumbing piping in the middle,cable b trays/conduits above lighting,and,the lighting zone immediately above the ceiling. Provide 6 inch minimum clear 1i s LEGEND space to avow the relocation of fight Ixtures 1 Viz' (E) _I i DEMO (E)HEAT RECLAIM (MIND PLUMBING PIPING 140'F.HW ROOF FLASHING ABBREV. DESCRIPTION ABBREV. DESCRIPTION LO V WATER HEATER &P8,T RELIEF VALVE = I I ASSOCIATED PIPING I_ CW DN GOWN TIC COLD WATER GENERAL UNION (TYPICAL)(E) i _ CO CONDENSATE DRAIN i _ He HOSE efae CO CLEANOUT Section Includes ==bi -_ Pipe and pipe fittings. C HMW DOMESTIC HOT WATERWR DOMESTIC HOT WATER RETURN ON DOWN TO GRADE Sanitary sewer piping system. th Domestic water piping system. Storm water piping system. 2"DRAIN W/ PRv PRESSURE RELIEF va.vE FCO FLOOR CLEANOUT Natural gas piping system. TEMPERATURE CONTROL SCW SOFT COLD WATER RD ROOF DRAIN Valves. —00 TO FLOOR SINK (E) SET AT 140'F 6"DEEP TRAP G CAS PIPING RWL RAIN WATER LEADER MATERIALS 36"X36"X2"DEEP 18 GA GALV PANEE), _ (E) EXISTING TYP TYPICAL Sonitory Sewer or Storm Water Piping,•Buried: m v W PIPE TO FLOOR SINK GA - (R) RELOCATED VTR VENT THRU ROOF PVC Plpe,ASTM D-1784,PVC socket fittings,and solvent-cemented joints. r`, I I (N) NEW WCO WALL CLEANOUT Sanitary Sewer or Storm Water Piping Above Grade: w � SYMBOL DESCRIPTION PVC Pipe,ASTM D-1784,PVC socket fittings,and solvent-cemented joints. 1 Domestic Water Pi ing Above Grade: O WATER HEATER PIPING DETAIL --_-- NEW SEWER ABOVE GRADE Copper Tubing:ASTM E 88,Type L,water tube,drawn temper,with ASME B16.22 wrought copper and bronze Q� 3 4 CONDENSATE DRAIN DETAIL SYMBOL DESCRIP71ON NEW SEWER BELOW GRADE fittings,solder joints or grooved end fittings and joints complying with ASTM B584. P101 NOT TO SCALE p101 NOT TO SCALE - NEW VENT Natural Gas Piping,above Grade,minimum working-pressure rating, rimory ressure greater than 2 psig but not O —CW (N)— NEW COLD WATER p p N04 en —HW (N)— NEW HOT WATER —CO— NEW CONDENSATE DRAIN LINE more than 5 psig)secondary pressure more than 0.5 psig but not more than 2 psig. I 1^. Steel Pipe;ASTM A 53 or A 106,Schedule 40 black,with malleable iron or steel welded fittings and threaded or � N^ - HWR(N)— NEW HOT WATER RETURN — - NEW FLOOR CLEANOUT welded joints. cc W —G(NJ— NEW GAS 0 NEW FLOOR DRAIN Condensate Drain Lines: 0 EXISTING COLD WATER Rooftop piping: copper tubing:ASTM B 88,Type L,hard-drawn temper with cast brass or wrought copper fittings O�. —CW (E)— EXISTING WASTE LINES and solder joints. Use ASTM B 31.95-5 tin-antimony or tin and silver solder,with melting range 430 to 535 deg F. —HW fE>— EXISTING HOT WATER ® O O EXISTING FLOOR SINKS. CASE Interior piping and piping thru roof: PVC Pipe,ASTM b-1784,PVC socket fittings,and solvent-cemented joints. ^ U W —HWR(E)— EXISTING HOT WATER RETURN d FLOOR DRAINS TO REMAIN Valves: t(��1 LO O HEAVY DUTY —G(El— EXISTING GAS �, ny EXISTING FLOOR SINKS. CASE Domestic water:Boll valves,2"and smaller,ASTM B 584,bronze body and bonnet,2-piece construction,chrome- �� CO NICKEL BRONZE —SCW IEI— EXISTING SOFT COLD WATER ` ` 8 FLOOR DRAINS TO BE REMOVED plated brass ball,conventional port,blowout proof,brass or bronze stem,Teflon seat and seals,stem extension for COVER CAP BELOW FLOOR. CONCRETE valves installed in insulated pip ng. Threaded ends.FLOOR TILE _N VANE CONTRACTOR TO PATCH FLOOR Natural gas(2 psig and lower):Gas stops 2"and smaller,AGA-certified,bronze body,plug type with bronze plug FINISHED or ball type with chrome plated brass ball. Include AGA stamp and threaded ends. CHECK VALVE � TRENCHING BY CONCRETE CONTRACTO pressure r (greater than 2 psig):Gas valves 2 and smaller,ASME 816.33 and IAS-listed bronze body and 125 psig FLOOR WALL ---- -- ��-•��� pressure rating. SURFACE YYY FLOOR DRAIN ES TO BE REMOVED J.R.SMITH tt4530 DRAIN ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS Hangers and Supports( Q Design channel support systems for piping to support multiple pipes capable of supporting combined weight of 1 HOSE BieB supported systems,system components and system fluids. GASKET SEAL/IRON � Design and obtain approval from authorities having jurisdiction for seismic restraint hangers and supports for piping PLUG -04(104- BACKFLOW PREVENTER and equipment. 18 Pipe hanger and support installation Comply with MSS SP-69 and MSS SP-89. Instoll hangers,supports,clomps, V TO BUILDING FLOOR COVERING 1 ALL SYMBOLS SHOWN MAY NOT APPEAR ON DRAWINGS and attachments as required to properly support piping from building structure. i A.F.F. (IF USED) i Provide thermal-hanger shields for domestic cold water pipes. SYSTEM Provide copper-coated hangers for direct contact with copper tubing. INTERIOR WALL EXECUTION i Use purging and disinfectingprocedures prescribed by authorities havingjurisdiction or,if methods ore not J.R.SMITH tt4250 6AS CALCULATIONS prescibed,procedures desribed in either AWWA C651 or AWA C652. �~ HEAVY DUTY CAST BEFORE REMODEL Branch shut-off valves shot at provided for all domesticindicated water. 1$"SD X 6"DEEP DISTANCE TO LAST CONNECTIONE 460 FT. Inst011 piping in Concealed locations,unless otherwise indicated and except in equipment rooms and service areas. IRON COVER EQUIP. MBH Provide air vents at piping ghigh points. 9 pipe p pipe CONCRETE PAD _� Maintain indicated fire ratio of walls,partitions,ceilings,and floors at i e penetrations. Seal i e penetrations FIN.PAVEMENT i SURFACE ., CONCRETE SLAB i AC-1 a70 with UL Listed fire stop materials. AC-2 470 Install piping indicated to be exposed,and piping in equipment rooms and service areas at right angles or parallel to building•wails. Diagonalruns are prohibited unless specifically indicated otherwise. _ AC-3 470 Install plp'ing to permit valve servicing. `LAJ) ;.-!;� i AC-4 470 Instoll frig free of sags and bends. rr�m� .,..•: pp i AC-5 27o Install fittings for changes,in direction and branch connections. THREADED i55�i-II FLANGE ING UH-1 400 Install pi�ppping to allow application of insulation. CLEANOUT PLUG C� UH-3 400 Install copper per water tube o drainage vent A ping according Tube ASTM�k 2665. edition. W -#'r�TO BUILDING WATER HEATER 199 Install undCerground PVC soilond waste drainage piping according to ASTM D 2321. sow and waste drains b W EXTERIOR SYSTEM SOVEN TANDBY GENERATOR 250 Installbuildipng attachments within concretese s or attached too structural steel. Instoll fire protection systems piping inde endent of other piping and ductwork.. Z Installhongers and supports to allow controlled thermolond seismic movement of piping systems,to permit freedom Z TOTAL CONNECTED LOAD 4.199 of movement between pipe anchors,and to focilitote action of expansion joints,expansion lops,expansion bends. O GAS PRESSURE 5 LB. Run water bearing pipe in heated spaces(excluding drainage piping when installed with slope). I�11 C iq PLUMBING FIXTURES AND SPECIALTIES U V s CLEANOUT DETAILS 6 FLOOR DRAIN DETAIL CAS CALCULATIONS GENERAL P701 NOT TO SCALE P101 NOT TO SCALE THIS REMODEL section closets. L�..� Water cloosets. DISTANCE TO LAST CONNECTION -460 F7. Urinals M EQUIP. MBH Sinks -single comportment. AC-1(E) 470 Service sinks. AC-2 (El 470 Electric water coolers. Il�y AC.3(E) 470 Icemaker outlet box. AC-4 (E) 470 Wall,floor and grode cleanouts. AC-5 tE) 270 Floor drains. v Reap seal primer valves. AC-6(E)-ELECTRIC HEAT 0 Reduced pressure backflow prevenlors. - AC-7<NI 115 ACI(N1 224 MATERIALS ■� AC-9(N) 250 AC-10<N)ELECTRIC HEAT 0 Manufacturers(Subject to compliance with requirements,provide products by one of the following( AC-1 (1< 115 AC-12 (N) 5 Water Closets: O ...iii... AC-13(N) 115 American Standard,Inc. AC•1 (N) 11 400 Kohler Co. 5 v AC-1 (N) 400 Eller Plumbingwore. U UH-1(E) 400 Water Closet Seats: O (� UH-2(R) 400 Bemis Manufacturing Co. Church Seat l n WATER HEATER (E) 199 Olsonile Corp.. Flush Valves: Sloan Valve Co. TOTAL CONNECTED LOAD 5,043 CFH Zurn Industries,Inc. GAS PRESSURE -5 LB. Urinals: American Standard,Inc. Kohler Co. fix/ Eller Plumbingwore. Lavatory Faucets: American Standard,Inc. Kohler Co Delta CommerciolFoucet Division. Fixture Carriers: Jay R.Smith,Mfg.Co. e Wade Division,Tyler Pipe. Zurn Industries,Inc. e>i Sinks: m= Elkay Manufacturing Co. Just Manufacturing Co. Moen,Inc. Sink Faucets: American Standard,Inc. L Kohler Co. O�4.z> O(STE F Delta Commercial Faucet Division Service Sinks: - Commercial Enameling 783 Kohler Co ` �l4400v of Service Sink Faucets: SATE OF A V. Bradley Corp. COTT IIA Chicago Faucet Co. Sloan Volve Co. Electric Water Coolers: Halsey Taylor. CTA JOB NO. Hows Corporation. Oasis. Wall,floor and grade cleanouts: DELLCC Joy R.Smith,Mfg.Co. Wade Division,Tyler Pipe. Zurn Industries,Inc. DRAWN CHECKED Floor Drains: DIETfZICH MACKAY Jay R.Smith,Mfg.Co. Wade Division,Tyler Pipe. DATE Zurn Industries,Inc. Trap•Seal Primer Valves: II/08/01 Precision Plumbing Products,Inc. Jay R.Smith,Mfg.Co. SHEET TITLE Watts Industries,Inc. Reduced Pressure Backflow, Preventor: PLUMBING Conbraco Industries,Inc. LEGEND, Industries Inc. .. Zurn Industries,Inc. SCHEDULES, EXECInstall eachfixture with tro g,p,easilyy removable for servicing and Cleaning. SPECS For lavatories and sinks subject to ADA requirements,provide.manufactured formed insulating jackets for all exposed wastes.P-traps,an� water supply riser fittings and pi ing. SHEET Provide stainless steel,braided,flexible supplies to fixtures with ball-type stops,reducers,and chrome plated escutcheons. Install components level and plumb. Set service sinks in a leveling bed of cement grout. Installand secure fixtures in place with wallcarriers and bolts. Seal fixtures to wall and floor surfaces with sealant,color to match fixture. Water Closet flush valves shall operate Without chatter or hammer at any inlet pressure between 25 and 50 psi. �..� Installbackflow preventors in each water supply.to,mechanicalequipment and systems and other equipment and Water systems that may be sources of contamination. Comply with authorities having jurisdiction. 01 G Install wood-blocking reinforcement for wall mounting and recessedbuw-typ[ e plumbing specia ties. Fasten recessed-type-plumbing specialties to reinforcement to into Walls. Installair vents at piping high point. Install ball valve in inlet and drain piping from outlet to floor drain. i Install chrome plated escutcheons at wall,floor,and ceiling penetrations in exposed finished locations and within cabinets and millwork. zo1 PLAN NOTES cF,_,----------------i MO EXISTING FLOOR SINK OR FLOOR DRAIN. CAP AND ABANDON WASTE - AND VENT PIPING BELOW FLOOR SLAB. PATCH FLOOR SLAB. .202 DEMO EXISTING VENT PIPE UP THRU FLOOR SLAB,IN WALL TO AND INCLUDING _ VENT THRU ROOF UNLESS OTHERWISE NOTED. CAP VENT LINE BELOW FLOOR .. Q Q _ � �LuLw _ SLAB. REMOVE FLASHING AND PATCH ROOF OPENING �\ 1• ������� I I 208 ' ��, i i V QI�Z 4� 203 DEMO EXISITINC SINK,FIXTURE OR ROUGHAN INCLUDING WASTE AND VENT" _ `1 PIPING. CAP AND ABANDON PIPING BELOW FLOOR SLAB OR..ABOVE CEILING G 204 DEMO EXISTING VENT PIPE UP THRU FLOOR SLAB TO ABOVE CEILING LINE. - I ' 1\ Q W 4 Z� ABANDON VENT PIPING BELOW FLOOR SLAB. REMAINING VENT AND VENT I \, 7- L_ I O Hz THRU ROOF TO REMAIN. 12 STORM DRAIN ) ------- p O _ORM N fE V ��_ 205 ABANDON EXISTING WASTE AND/OR VENT PIPING BELOW FLOOR SLAB. I I I I\\ I '�� I — i 202 - - - - _ - _ - - _ - 1 j \ m I \\ ! 1------ ---'�--- --__'ROOF-----I-RWL (E)•------ ---r-- -- A , 206 EXISTING FLOOR CLEANOUT TO REMAIN,REPLACE ClEANOUT COVER AND I I '-�DRAOIN (E) REVISIONS FRAME TO MATCH NEW FLOOR FINISHES. I ! \ I 1 i' DRAIN (E) 214' I 214 1__.__ 21.3 I 207 DEMO EXISTING FLOOR CLEANOUT. CAP AND ABANDON WASTE PIPING I \ 1 II r--- I /a"CD (N) ` BELOW FLOOR SLAB. PATCH FLOOR SLAB. i I \ �-- -' ' I ' 2171 C I -- -- -V \ I -- - I ---------- - 208 REMOVE CONTENTS OF EXISTING GREASE INTERCEPTOR. CAP INLET, i I \ I 8"RWL (NF I �r--- - OUTLET AND VENT PIPES,COMPLETELY FILL WITH APPROVED I I \ I , '8E RWL RIF I _ y FIELD VERI Y MATERIAL,CALL FOR INSPECTION,REMOVE LIDS AND RISERS. I \ j. 1 kIEL� VERIFY SIZE,MATCH fE) I ".' I, , I I I \❑ 1 ATCH (E) __ 205 CD (N) 209 DEMO WASTE LINE FROM PLATFORM ABOVE. FILL FLOOR SINK ON PLATFORM WITH CONCRETE. CAP AND ABANDON WASTE PIPING BELOW FLOOR SLAB. 10"RWL (NI, I FLOOR SLAB. I I I I FIELD VERIFY J L , 9 (N>, d� _ ----- PATCH 1 .. 210 EXISTING WASTE LINE FROM PLATFORM TO BELOW SLAB TO REMAIN. I I ! I 206 21d CH fE> , 1 i ?/ SIZE,MAT 3 I In - 212 p oZ li 8 211 DEMO EXISTING FLOOR SINK AND WASTE LINE. CONNECT NEW 3"WASTE ROOF 73 (N) I ROOF I EXISTING RWL DOWN 213 i 11 (N) I ' 2 CD I III LINE TO MAIN AND INSTALL NEW SERVICE SINK. I 212 2"CD <N) "("-- ^ O I �' lN) I1oII 212DRAIN (E) DRNN (E) I TO BELOW GRADE p I p _____212 2"STANDPIPE UP THRU ROOF WITH 6"DEEP TRAP BELOW ROOF. RUN 204 0 (N) 2"CONDENSATE DRAIN LINE BELOW ROOF,DROP DOWN IN WALL AND DRAIN ,RWL (E) -- L N)-r� I - - - - - - - - - - - - rl , , II 201 INDIRECT TO SERVICE SINK,FLOOR SINK OR FLOOR DRAIN. VENT 2" CD <NI --S_�y - - ----_-_---_" - _ LINE WITH 2"VENT THRU ROOF. LOCATE VTR 10'-0"FROM AC UNIT I M' �---'NTAKE. PLUMBING CONTRACTOR TO FIELD VERIFY CONDENSATE +� I 2"CD <N) ' 's "CCDCD IN) -1CD -,- L_l - it 2 - I - - - - - - - - _ � ',--___ � 202 1 ".. ' 'I,I (N) 201 t. II I ,. DRAIN CONNECTION LOCATION WITH ACTUAL EQUIPMENT PROVIDED BY I_ ------ SEE - - ---- - - - - _ -- _______ _1=-- -----=--j =- - I' -_ MECHANICAL CONTRACTOR. SEE DETAIL 4/P101. -, '---"'- I - -� ------------ -__ '---- -- ---- - - I I , I SEE 31P201FOR ----'-- r-- ___ ----- - - - " I yi=___ -_ - 201 i-----',I 207 I u 202 ,) NEW PIPING IN III \ v, I I , 2 202 ?Q�'' , \L'` III I 1 213 CONNECT NEW PIPE TO EXISTING. Q } I •" 201 l4 �II I 202 III N Ix , �_ THIS AREA .. I f 214 'REMOVE EXISTING RAINWATER LEADER OVER THE DATA CENTER AND UPS, I i iti it , Y0t I 209 I Q ) ' ° RELOCATE TO NEW LOCATION SHOWN. REUSE PIPE AND HANGERS IF I I ry I I 1 .. 207\ I 201 II %20, 201 201 ' �2°CO N 20j3 203 �, 207 POSSIBLE,MATCH EXISTING PIPE SIZE WITH NEW PIPE. - ------ 1-- r ' I ^ p I' I +I I ' Il\ Ii• 215 I ''` - - - DEMO EXISTING CONDENSATE DRAIN TO FLOOR SINK. 12 fN) ' 'P I, 201 ' 6 I`--'--II ' u \ I u 201 I 1206 11 '---'--_ . DEMO EXISTING 4"WASTE LINE DOWN IN WALL TO BELOW SLAB. RUN I I r 202 ij I I ` ' ' 20Y '202 ^` 'I I` I` --0 -- W W 201 I I ' `�`. O' ' I �r� II `. I L . - 'r-J_---- ��-.._..-. -/�J , - II �7!' 1N III III -"--------------- -- D 2 I` 216 - -\ O - TO NEW WALL AND RUN DOWN TO FLOOR BELOW.SLAB. PROVIDE NEW �..,„- I ii 201 I -" I-J" 207 -_ I- __-_-__„-----.-" ' ^ ""••= -•- --��- II'�'- - - - - - ,, F202 CO. 202 - 217 1'/,'PUMPED CONDENSATE DRAIN LINE FROM COMPUTER ROOM AC UNIT, �_"- "' III r I I_ ___ _ INDIRECT DRAIN AT SERVICE SINK -- ---_-_ -'-- - --- --- I ' 206 2"CD (N) I , :•------`----- --�t---'-+r- + 203 R" I 2"CO IN -- - -- ---------------- ---- - 1------ - -,--- •- -\ -----------------j----� L2� 1'--4"GREASE fE)--- 1- . T----j------ �r----\- - --- ------------ ---- 4„SANITARY (EI T 206 --- 1 ---z„CD <N>---CsENERAL NOTES / -------I A ' I 1 203 .. i -_-1 203 -1 1 203 I 1 (E) i , , � IE) I 1. CONCRETE CONTRACTOR TO PROVIDE CONCRETE SLAB CUTTING,TRENCHING, I �'' f I I I ' 15 215 ' I ^ I 2"CD (N) I 203 \ . ws 201 � A' N�- ,v 1 f- -------------r1 14 ---I--_--_----'TI CN1 I f-� '\.� I r coM BACKFILI COMPACTING AND CONCRETE FLOOR PATCH. r �' I I FF++ fN)_•- 1 , O `i. I 1 201 \I\` -t 2. ROOFING CONTRACTOR TO REMOVE ROOF FLASHING AND TO PROVIDE I ^ I 1 ' 1 ' 212 i 212 213 v ' 1 I I \`` 207 w ROOF PATCH. 1 I I i I °--------' °-------- La M 1 I \ I I �1 ao 3. PLUMBING CONTRACTOR TO'SCHEDULE PHASING OF CUTTING AND PATCHING /� a I I -' I 201 , I , I 206 5 O WITH OTHER TRADE CONTRACTORS. ' I .'I I I I 4. PLUMBING CONTRACTOR TO CUT,CAP AND ABANDON PIPING BELOW FLOOR I i I I , ------, i 201 ` --/I\ I w I I I my SLAB OR IN WALL STRUCTURE TO ALLOW FOR LEVEL FINISH WORK. PIPING I i I I f�l a ABOVE CEILING,EXPOSED AT STRUCTURE OR WALLS TO BE DEMOLISHED TO 2"CD BE REMOVED. DO NOT ABANDON EXPOSED PIPING IN PLACE. REMOVE LINE DOWN II I I `-� I I HANGERS,FITTINGS AND BRACKETS WHEN REMOVING PIPING. IN WALL f-• I I CD fE) ` ,e. -_--- �I I --------0 I O I - -<- - -----�------------- - - -'_ �-----------o----------------------- -------------- ------------------ - - - -'- - -�- - - < ;- - - - fT 5. PLUMBING CONTRACTOR TO REMOVE AND LEGALLY DISPOSE OF ALL MATERIAL. I I EQUIPMENT AND FIXTURES REMOVED FROM PROJECT. OWNER RESERVES THE I a I I RIGHT TO RETAIN ANY MATERIAL,EQUIPMENT OR FIXTURES. I� ''� 1 I ! 1�------ - ! ! I M I L... 6. SLOPE ALL SEWERS I/."PER FOOT WHEN POSSIBLE.NO LINES SHALL BE eat INSTALLED LESS THAN %"PER FOOT SLOPE. I , I 7 PLUMBING CONTRACTOR TO DISCONNECT AND REMOVE DRAINS FROM ALL ! I 407 I I 1 O N SINKS AND PLUMBING FIXTURES BEING REMOVED AND CAP BELOW FLOOR I I I I\ I 1 OR FLUSH WITH WALL. DISCONNECT AND REMOVE ALL VENTS THROUGH I I I I I <v I .1 a 0! V W ROOF & CAP BELOW FLOOR. I I f Z 8 DATA& INFORMATION SHOWN ON PLANS HAS BEEN TAKEN FROM REMODEL (D BUILDING DRAWINGS. THE CONTRACTOR SHALL FIELD VERIFY EXISTING JOB I b i NO WORK UND IR DEMISING CONTRACT SITE CONDITIONS. ACTUAL LOCATION OF EXISTING SEWER LINES MAY DIFFER 1 I ON THIS SIDE F EMISING WALL FROM THAT SHOWN ON THESE DRAWINGS. ' EXISTING SYST MSI TO REMAIN 9 REFER TO ARCHITECTURAL DRAWINGS FOR AREAS TO RECEIVE NEW WALL ' I II COVERINGS OR FLOOR FINISHES. IN THESE AREAS EXISTING PLUMBING I I FIXTURES,BEING REUSED. SHALL BE REMOVED TO PERMIT WORK TO BE I "' -------/I 201 y I I DONE AND THEN TO BE REINSTALLED. I I I I I I I ° 10 PRIOR TO STARTING WORK PLUMBING CONTRACTOR SHALL VERIFY DEPTH I I 41 t Q�1 OF ALL EXISTING SEWER LINES AND ADVISE ARCHITECT IF THERE ARE ANY PROBLEMS WITH ELEVATION. I I .. I•"'( 11 PROVIDE AND INSTALL TRAP PRIMERS WHERE SHOWN 201 I I I w ^ ~~ I I 12 REMOVE ALL EXPOSED UNUSED WASTE AND VENT PIPING. I I I I I I y Z 13 EXISTING PLUMBING FIXTURES TO REMAIN OR BE RELOCATED. THE PLUMBING - CONTRACTOR SHALL PERFORM THE FOLLOWING WORK: A)REPLACE ALL MISSING COVERS FOR FLOOR CLEANOUTS AND INSTALL I I I I I I I a 207 / NEW GRATES ON FLOOR DRAINS WHERE BROKEN OR MISSING. I I / -----------_---_ �1 B)REHANG LOOSE FIXTURES. ---- ---------------- --- --- - ----- --•-------------•-'----------------_ 207 -- - - - - I - I I I - - - - - - - - - - - - - - - - - - - - - - - -y - - - - - I I r^ C)REPAIR LEAKING WASTE PIPING I 1 I r� I I I I I 201 I I I 202 14 FLOOR CLEANOUTS SHALL BE INSTALLED WHERE SHOWN OR AS DIMENSIONED. I 1 I i I I I Lu SHALL NOT BE LOCATED IN TRAFFIC AREAS. I 1 I I 201 W 15 WHERE EXISTING PIPING IS SHOWN,BUT NOT NOTED,THEN NO WORK IS ANTICIPATED. I h <v I 16 NEW PIPING AT EXPOSED STUCTURE TO BE PAINTED TO MATCH ADJACENT I I ••' I I I�\------ PIPING. PAINTING BY PAINTING CONTRACTOR. i i j 20t 201 I V i U LouI � I I I I I I ,------'• I y i - "- - -" - -"-• "-. _ I -•T-- - - -- I - - - - /� � zos I I I I q ^ 'ju I I I i 201 SEE DWV WATER ------ �1 I\I RISER 2/P101 FOR EI ill /I I\ NEW DWV PIPING i i I-1 1 ' \� ' -/I\_-_-- s i t•-1 2"CD (N) U P-4 I (iYP 5) ni �4J Q I F ` I I 1 • I I 20t I i ; I I -- I ' I' ^ ' ` - - - - - - - - - - II ------h ---------¢- ---•- 1 - - - ------------- - ' _ �/ - � - - , -, - - - -tot ----/I s —i \\ I I YP.5) SEE DWV WATER I I ------ ' ' ' ' l ' ' 6 RISER 2/P101FOR P-5 I I `� -----_1 I I `--r---' I (E) I NEW DWV PIPING I I II ` P-7 ' I I` I 202 201 I IJ , i I II00 \ I ------/I; I ------ ---------- -- z07 I CD (E) - \\ P-2 I li I I 207 I P 3 \ I i II I <i j I I�•y.7 I C I it --`V I j I I I I n Ir � �� I 201 P.3 \ 1 i I \ c LI 201 I I j 2„CD (EI III Ti ��E CO (a) n1 ' P-, 213 ! I 203 207 j .....` i I i3z R 11 CD (N) -�---___----' --CD-- \__--- --CD-- _---ii-- CO (N) I ' \ 205 t r 206 I I 205 2„CD (N) - Q-- -- - ----------------- -�- - —:� - - - - - - - - ( i ) \ ii `� I I lii I I 201 I1 I III 2"CD IN) I a� 783 REIP20V1 F012, J I I GO I I I I 'J CONTINUATION 29 202SC E ov O�- 11- -+-i---F---- -- - - - -----_i OTT MP 3 PARTIAL DWV PLAN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P2ml SCALE: "=I'-0" _• ! I 0 1 111 I P"6 _ .� z�; - ,I 203 f 213 �// I I 201 I i i I-7/ 41 GTA JOB Mo. 218 " I 211 _ ..af j i n 202 ---- _ _ -_- ' itdl 203 FCO <N) r u _.�_--�ri•r _- _)-rry( +----_-"-----------0 DELLCG I - - - ---- --- - - - - - ---- - - - - - - _____—____'� - - - - - - ------ , /F. �_� vrrrarrra :rarrra , ,I l i ' 4"WASTE <N) I �.. I I I `u ' ,{ ' I _ I I �- ------ -- -- - - -�_�' - - `---------•-------- K DRAWN CHECKED I _ - __ ....--.-_-_- ---.---. - -� ---_- -.-.---.-_-_---"- -I "�1-------r---- --- - - -- ---J 1 DIETRIGN MAGKAY i ------' -- I ii 206 I I / n. a DATE EXISTING 2"'WASTE RE:P201/2 FOR 213 I�' �I I i +r i,7--- // 9 ni05i01 FROM ABOVE{ 1 CONTINUATION I_ "� � SHEET TITLE �11111i1,�• I T i ®' r'. j j ' h ti II I1' I —- -- -- - - - O DWV DEMO :__-----1 i' -_� ° REIP201/1 FOR �• I ` , `L d� I �, ODEL CONTINUATION - I I J `\. I '` EXISTING WASTE \ -O PLANS I \ I ` _ _ 1 ' ------4.,SANITARY (E)----------- '-------------------------------'- ' `•. j SANITARY fE)-----------------r----------- r -- DRAINS(E) - - gI I ` ' TO REMAIN -------------------------------------------.- -_---"-"---_-.-----_-_-----.---"-.-_-_-_-"-----_ SHEET CANOPY DRAINS(E) I I I TO REMAIN j I I I MEZZANINE DWV PLAN I I 1 DWV DEMO d REMODEL PLAN (�J 1 m P201 9CAL&%s•I'-m" I I P201 SCALE,vp".1'-0' P G 0 1 ��ii 17 0 d I^ I O PLAN NOTES n CAS CALCULATIONS 301 DEMO EXISITING FIXTURE OR EQUIPMENT.'DISCONNECT WATER LINES TO I cv U Lu LL BEFORE REMODELABOVE FINISHED CEILING OR BELOW FINISHED FLOOR. I I I I' I I QLu Lu DISTANCE TO LAST CONNECTIONE -460 FT. EQUIP. MBH 302 DEMO WATER PIPING,FIXTURES,AND EQUIPMENT FROM COFFEE KIOSK, (�=V U CAP AND ABANDON WATER LINES BELOW FLOOR SLAB. PATCH FLOOR.. AC-1 470 I I j I j j 1'/4".4 i U •N AC-2 470 (N) GAS METER (EI I ce Z p z AC-3 470 303 DEMO AND CAP EXISTING WATER LINES AT ROOF STRUCTURE. I I I I 314 1 5# HOUSE SIDE 0 Q LLI t9 Z AC-4 470 Ed AC-5 270 304 ABANDON EXISTING WATER LINES BELOW FLOOR SLAB.. j - j I i i �'' 31 (N) 314 PRESSURE C, UH-1 400 305 RELOCATE EXISTING ELECTRIC WATER HEATER AND DRAIN PAN TO NEW I - - - - - - - - OINI_ m m= UH-2 400 LOCATION ALONG SOUTH WALL. RECONNECT PIPING. I I I I f ,+ , WATER ENTRANCE AND ___ �_G_____--- ------- 400 1 I I I I I 11 - �I - I I 307 2"REDUCED PRESSURE REVISIONS WATER HEATER 199 N) GAS .. r + BACKFLOW PREVENTER (E) OVEN 250 306 INSTALL NEW SERVICE SINK. CONNECT TO EXISTING CW AND HW LINES. i i 1 .(N) I • 'I + �a"G 04) ____ I '/a"GAS (E) y+- I STANDBY GENERATOR 400' 307 DEMO EXISTING UNIT HEATER AND GAS PIPE. CAP GAS PIPE AT ROOF I I 2, �` /z'j GAS (N) TOTAL CONNECTED LOAD 4,199 STRUCTURE. I I 1 I I 12 - ---- ��)) \\ G (�J) : G fE) '� G C GAS PRESSURE 5 LB. I - - I. I (R>400 MBH I ""GAS CE U "GAS ( --------- ----- - 318 308 DEMO EXISTING HWR,CW AND HW PIPING FROM THIS POINT TO DEMISING P. -.,* GAS (N) 73 313 11 Ir WALL. CAP PIPING. I I I I I 312 1',i'�'GAS (E) 313 I(' ,I GAS CALCULATIONS 309 DEMO EXISTING HEAT RECLAIM WATER HEATER AND PIPING ON PLATFORM. I I' - -- ' 313 RECONNECT PIPING AS SHOWN ON DETAIL 3/P1O1. HOT WATER CIRCULATOR I I I 321 Wr,` I - I 8 ' THIS REMODEL TO REMAIN. DISTANCE TO LAST CONNECTION • 460 FT. I 1 I - GAS '(' , (N)224 MBH - 310 EXISTING GAS FIRED WATER HEATER AND PIPING ON PLATFORM TO REMAIN. I I I (E)19 MBH -� fE) 3 EQUIP. MBH O '" ' i 316 21/2"CW (N I I I I 34"GAS ij. I AC-I(E) 470 311 DEMO EXISTING WATER LINE BELOW FLOOR SLAB WHEN FLOOR IS REMOVED 310 ---Y'' - I (N) ' ' 9 II Ih AC-2 (E) 470 FOR NEW TOILET ROOMS. I I 1 I P I °� ( •____' �I AC-3 (E), 470 \Ir (N)250 MBIi4 z I AC-4 (E) 270 312 REMOVE AND RELOCATE EXISTING UNIT HEATER,PRESSURE REGULATOR t " I 316 I II 3 AC-5 (E) 270 AND GAS PIPING. RECONNECT GAS AND PRESSURE REGULATOR VENT PIPING 373 313 ') 1 313 <N)115 MBH II` AC-6 (E)-EIECTRIC HEAT p (E)400 MBH �4' GAS (N) I j I 11"GAS (E) I ❑ I I 301 i 301 301 v TO EXISTING. ______ :� - B AC_7 (N) 115 GCE) _ _ _ __ _ GG - -,----- 316 °-----'-------------- -------- ---- 'i----- - --- ------------------ AC-8 (N) 224 HWR <E) ___ ""-- ■.....'!}""-""-"-"._ _ __ __ "'F""-'"'"'""'"" HWR <t) — ,_ ---�i I -�-- -'I O 313 CONNECT NEW PIPE TO EXISTING. v HW fE) --�- r----- --M+ HW (E) AC-9 fN) 250 CW (E) --- - , AC-10 <N)ELECTRIC HEAT I ---------' ------'- ----"-- -"----"-- ------_____ - -r--= ---- -- _- _- --- 314 DEMO EXISTING 1/4"GAS LINE FROM METER THRU WALL TO ROOFSTRUCTURE. r- - -- -- _________ _a U-_____,�,r==- ------ --------- ----- - - AC-11 CN> 115 REPLACE WITH NEW 2"GAS LINE EXPOSED ALONG BUILDING WALL,THRU WALL yI +---"'�-' ' I .: -------� SEE 3PPNNG FOR AC-12 (N) 275 I yl , I,I / HWR (E>.'' II `x'.GAs I u .0 II ' lJ AND UP TO ROOF STRUCTURE. SEAL PIPE THRU WALL. I I 308 301, , ' �I' 309 1�/� CW.fE) , ( I / HWR,<E) ) , I, (� ` NEW PIPING IN AC-73 (N) 115 h 320 , 317 I 1 '(N7 4 HWR CE) HWR•(E) yl I 1/� jdW (E) /° V:. ,I THIS AREA AC-14 (N) 400 315 CONNECT NEW 4/j'GAS LINE TO EXISTING. RUN NEW 4/4"GAS LINE AT ROOF I yl 303 �, f I 13 �i I 2:.,pyy (E) u AC-15 (N) 400 STRUCTURE PARALELL TO EXISTING. I y I r- ( 1/4 HW (E) 2 HW I(E) 1` ' it I<N>11S MBH I I , yr 2"AAW (E) 2"CW IfE> -----------,--" �i'GAS /4"GAS CE) 1n;. I UH-1(E) 400 i 7i I d ' '' i O I <N) ig_____ ' HWR <E) UH-2 (R) 400 316 NEW GAS LINE UP THRU ROOF TO NEW A/C UNIT.PROVIDE ROOF FLASHING. , I, I , I 316 ,,.}'� , it _ HW PROVIDE GAS PRESSURE REGULATOR TO 7"WC GAS PRESSURE ON ROOF. I I }_� ________-- _� '� " ' . :-----Ii —r,=�T,�CW (E) i (� --- __ WATER HEATER (E) 199 CONNECT TO UNIT WITH 6"DRIP LEG,UNION AND GAS STOP FULL SIZE. REDUCE I ', III 12 '' _ " ii " ,n Y �+` y I ' (N)275 MBH i 'I ,' I\ PIPE SIZE ONLY AT UNIT CONNECTION IF SMALLER THAN PIPE SIZE. PLUMBING \ w � I I\� I 301 CONTRACTOR TO SIZE 7"WC COLUMN GAS LINE CONNECTION TO UNIT AND VERIFY \...,,. I n i 4i• ` - , -_ _- ' ---•-•-•-•-• '�"�----- ----- UNIT PIPING CONNECTION WITH ACTUAL EQUIPMENT SUPPLIED BY MECHANICAL s"" ' 3 +I ,,.____,.( '------- ---_- , ( p 'c--li-- I"y- -- '---•- I ' ---•-•-"-`-'-'-----0 TOTAL CONNECTED LOAD 5,043 CFH CONTRACTOR. J i N u i " " it - I J+` `I� - - = 4-- - I' :1,,�, ` I , c� I _f l I:__ ------------ '_= ���I -__� GAS PRESSURE 5 LB. 317 I .. .• ' DEMO EXISTING GAS LINE,PRESSURE REGULATOR AND VENT LINE SERVING ` w -,--.,- ___„-,n l � --- .. 1111t_------------------ GENERATOR ON PLATFORM. PATCH ROOF. ---- ------------ 3: -------_-� ------------- ' 318 DISCONNECT AND DEMO EXISTING 2"CW LINE DOWNSTREAM OF EXISTING = -'�/ 301 301 14 G (N) I 301 301 I 301 I 301 PRESSURE REDUCING VALVE. RUN NEW 2'/2"CW LINE IN SAME LOCATION w (N)400 MBH I �4"GAS I I TO A POINT DOWNSTREAM OF NEW TOILET ROOMS.. 3 319 EXISTING FIXTURES TO REMAIN _ I i I I , I 301 , 301 N 320 ABANDON EXISTING PIPING IN PLACE. I I i , i i I _ 2 I 301 318 i-I 15 ------- 313 , I 321 E%ISTING GAS FIRED WATER HEATER ON PLATFORM TO REMAIN. 700 GALLON SCW(E) I , i i ' ' i (N)400 MBH I i j i i (E)470 M�H 313 m STORAGE,199 MBH INPUT ' (r)470 MBH .________� 316 ' ' I--I I I/z GAS (E) I -' j w N 3 n O I I I/p"GAS (E) --'---_I m GENERAL NOTES w � 2"CW (E) l 1. CONCRETE CONTRACTOR TO PROVIDE CONCRETE SLAB CUTTING,TRENCHING, I I ! -O U I O BACKFILL,COMPACTING AND CONCRETE FLOOR PATCH. --------'------------------------- ---� -------- -------------- •------------------------------ -- --'-•------------ E 2. ROOFING CONTRACTOR TO REMOVE ROOF FLASHING AND TO PROVIDE ROOF I w PATCH. 1"GAS (E) I O LLI 3. PLUMBING CONTRACTOR TO REMOVE AND LEGALLY DISPOSE OF ALL MATERIAL, I no!M EQUIPMENT AND FIXTURES REMOVED FROM PROJECT. OWNER RESERVES THE rI�.4 RIGHT TO RETA)N ANY MATERIAL,EQUIPMENT OR FIXTURES. i I I O n-(•-( ILl>p 4•PLUMBING CONTRACTOR TO SCHEDULE PHASING OF CUTTING AND PATCHING ! I 1 I /'� O c'v WITH OTHER TRADE CONTRACTORS. I I I �LI U w 5.PLUMBING CONTRACTOR TO CUT,CAP AND ABANDON PIPING BELOW FINISHED I I 1 Z NO WORK UNDER THIS CONTRACT Ln O FLOOR SLAB OR IN WALL STRUCTURE TO ALLOW FOR LEVEL FINISH WORK. ON THIS SIDE OF DEMISING WALL PIPING ABOVE CEILING,EXPOSED AT STRUCTURE OR IN WALLS TO BE - EXISTING SYSTEMS TO REMAIN DEMOLISHED TO BE REMOVED. DO NOT ABANDON EXPOSED PIPING IN PLACE. REMOVE HANGERS,FITTINGS,AND BRACKETS WHEN REMOVING PIPING. 6. DATA AND INFORMATION SHOWN ON PLANS HAS BEEN TAKEN FROM BUILDING REMODEL DRAWINGS. THE CONTRACTOR SHALL FIELD VERIFY EXISTING JOB SITE CONDITIONS. ACTUAL LOCATIONS MAY DIFFER FROM THAT SHOWN ON THESE DRAWINGS. I I I 7.WHERE EXISTING PIPING IS SHOWN,BUT NOT NOTED,THEN NO WORK IS I ANTICIPATED. I I I U rT 8.NEW PIPING INSTALLED EXPOSED AT EXISTING EXPOSED PAINTED ROOF STRUCTURE TO BE PAINTED TO MATCH ADJACENT. PAINTING BY PAINTING ~/ y CONTRACTOR. — — —-—-—-—-—-—-—-—-—-—-—-—-—-—-—-—-—-—-—-—-- -—-—-—-—-—-—-—-—-—-—-— -—-—-—-—-— — — — — — — — — — —I -----•-----•-- -—-—-—-—-—-—-—-— —-—-—-—-—-—-—-—-— — — — — — — — — — —OF U i V w Iv I I I 303 P-8 P-1 P-2 � I I a V"I 3 c3i IJ..I - - - - - - - - - - - - - - ---------•-•-•----� xW I i I I I Z i 313 O I P-9 CWMN) (W373 ME IC Ak I I ------ RE 1/P301 FOR I RISER 1/P101 FOR W CONTINUATION NEW WATER PIPING 313 I ' O 313 I y4l GAS (v J 313 (N1 I I V AYP ) ) ----------------— I I 1 7 D j (N)115 MBH ^ w (TYP 5)SEE DOMESTIC WATER I 1/2"GAS (E) A I — RISER t/P101 FOR G (E) G (E) I I NEW WATER PIPI G,• ------- -- -- (E)470 MBH j P-7 i � I ''/z"GAS (E) I i I i I O P_3 U 3 1 1 I r i I v O ce (E)470 MBH I I I j I , j '-•-•- ' ------- -- - - - J'--------I-•-'-'-'-•-- ------- ----------------- -�- l c l. I I I 1..GAS (E) I I v j I W U ,....,2"CW (E) I RE'1/P301 FOR ��4 i t 1 1 I I i - •• CONTINUATION \ , WATER AND CAS TOILET REMODEL W P301 SGALE:ye"_I'-m" - -- ,, J `w' �� I o I 301 �1' 304 I 1 1 ')-7 301 i , �OFV.y�O+STER CY^i^' I CW (E)�—',' O sossw#I — — — — — — — — — — — — — - - '�'-- =_____ ----- �oriMnc - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � - - 7p===== +r - - - - - - 2"CW (E). 1"GAS CET ;'' / -I- ------------ I REn 2/P301FOR I RE:2/P301 FOR 303 �Of CONTINUATION. CONTINUATION. I 1 305 301 GTA JOB NO. REn 1 P301)FOR 15 GAL ELECTRIC 1' GAS <E> I / _, I 1 �' ��� 303 ' Ii_ � 303 RE'7/P301 FOR _ _ _ _ _ . CONTINUATION WATER HTR (E) CONTINUATION —_—_— _—_—_— — — — — —_— _— —_— — --.—_—_—_—_a( _—_—_—_ _—_—_—_—_—_— _—.— — _—_—_—_—_—_—_ I,I I, I 1 I , 2"CW (E) 'T•----- r--- TT r------ r—?i���_,_�� _� W fE •-- --- -—-—-—-—-—-—- —-—-— K DRAWN CHECKED L -""-_ --- a )5'HW I / _—_—_—_—_—_—_—_—_—. _______I_� it I I I I— 319 DIETRICH HACKAY LL — — ) — 319 319 DATE LE n� ______ _ _____ _______________J - I 11/0S/ml -7 I j � SHEET TITLE S (E)270 MBH ____-' I --� 1 ; y 1 ' I ' - ---•---- WATER d GAS CW (E) ' I .... �\. .. ` DEMO d REMODEL i i - � ' ----;------------------------------------------i----------------i---•---------------------•-------•---------•----------- ------------------------------------------------- ---------- SHEET 2 i j I j WATER AND GAS PLAN 19 WATER AND 6AS NEZZ PLAN �� P3mI scAL=_/'=r-a' I 1 I P3oI SCALE:%°.r-m" �c rLAIV NL/I C1p 401 EXISTING 6"UNDERGROUND FIRE WATER MAIN AND EXISTING 6"AMES MODEL 2000SS DOUBLE. CHECK ASSEMBLY G -FIRE EXTINGUISHER • FE,CABINET-FLUSH MOUNTED:UL-RATED ABC; 402 EXISTING FIRE SPRINKLER RISER,FIRE DEPARTMENT CONNECTION,FLOW SWITCH AND TAMPER SWITCHES. �,\ 10 Ib NOMINAL CAPACITY IN ENAMELED t 1 J STEEL CONTAINER. 403 NEW ENCLOSURE AROUND EXISTING FIRE SPRINKLER RISER BY OTHERS. cV •ONE HOUR RATED PARTITION WALL J i I-- LW LLJ LLL-H H 404 EXISTING INSPECTOR'S TEST AND AUXILIARY DRAIN. I -5/8"TYPE."X"GYP.BD.BOTH SIDES I I = Q H f i TO ROOF DECK. I i Vy...', Z • 405 TYPICAL EXISTING 2"GRIDDED OR DEAD END BRANCH LINE WITH UPRIGHT HEADS. v MODIFY SPRINKLERS AND PIPING AS REQUIRED BY REMODEL,INCLUDING BUT NOT LIMITED TO: i 60• 60 MINUTE RATED DOOR ASSEMBLY. 1. NEW OR MODIFIED INTERIOR WALLS I I 1 1 I I i Q LLJ `_^Z w 2. NEW OR MODIFIED EXPOSED DUCTWORK CODE INFORMATION ao, O �m 2: 3. NEW OR MODIFIED CONCEALED DUCTWORK I I 1 I I r 4. NEW OR MODIFIED SUSPENDED CEILINGS _ _ _ __ . A 5. NEW OR MODIFIED LIGHT FIXTURES I CODE INFORMATION I I i I I REVISIONS 11 6. NEW OR MODIFIED SUSPENDED WALLS AND SOFFITS I I UNIFORM BUILDING CODE 199T I I 1 1 OCCUPANCY GROUP .............8 404 , 406 EXISTING FRONT CANOPY WITH DRY SIDEWALL HEADS. BUILOWG CONSTRUCTION TYPE III-µ FULLY BPRINKLERED. I 1 I 402 407 PROVIDE NEW NITROGEN SUPERVISED,DRY-PIPE PRE-ACTION SYSTEM TO SERVE DATA CENTER AND i ONE STORY WITH MEZZANINE,SEPARATION ON TWO (2)SIDES. I m UPS ROOM. CONNECT NEW DRY-PIPE SYSTEM TO EXISTING RISER. REMOVE EXISTING WET PIPE ZA SYSTEM FROM WITH-IN AND ABOVE THIS SPACE,INCLUDING MAINS AND BRANCHES SERVING THE REMAINDER OF THE BUILDING405 408 EXISTING ROOM AND FINISHES TO REMAIN,NO WORK REQUIRED I I 1 1 I IL ---- ----- - _-_--_-_- ---- 409 EXISTING MEZZANINE LEVEL -EXISTING ROOM AND FINISHES TO REMAIN,NO WORK REQUIRED i 1 i .. i i ____ 4 5 410 EXISTING SKYLIGHT tL GENERAL NOTES i m ® i- 1. FIRE SPRINKLER CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF EXISTING SYSTEM. 2. DUCTWORK SHOWN ON THIS DRAWING IS EXPOSED. ❑ - - - - - - - - - - - - - 3. DUCTWORK,DIFFUSERS,GRILLES,LIGHT FIXTURES,AND CEILING MATERIALS SHOWN ON THIS DRAWING ,�_-�-�� �� (?tl l _ ARE FOR REFERENCE ONLY. - - - - - - - - y A` • +" °4 t C" IT�X�' --.. .' 405 405 I J r 405 1 ® 405 tx s'' s•.. - - - -- - - - - - - - - -- ... I , : I I I OM IF•fr•'�. M M ®s s I I I W o i 40 on O-X- I I - - t0 I 10 I I LI' I 3 FIRE SPRINKLER RISER (E) - - T - - - - - - - - - - -- - - - e�. - - - - - - - --- --- - f - -ra- ------------- - 4 1 I----------------------------------- ---------- NOT ;- - - - - - - - $ E FPmi TO SCALE w \ ry PHOTO PROVIDED FOR REFERENCE ONLY - M N Wo >o FIRE PROTECTION SYSTEMS GENERAL I I I I W l/�I ri/•��,) N Q NO WORK UNDER THIS CONTRACT ►�•�•1 Scope:The Contractor shall design,install and coordinate all fire sprinkler work to provide complete and ON THIS SIDE OF DEMISING WALL II I 1 d operational fire sprinkler installations. Provide complete engineering design including design drawings,material EXISTING SPRINKLERS TO REMAIN i 405 specifications,and calculations. Drawings shall beer stamp and signature of NICET certified designer,Certified in I I the state of Idaho. Supply and install complete fire sprinkler systems throughout to complete project for fire V J sprinkler systems described herein. lw Section includes: Modifications to e- existingsprinkler wet-pipe sprinkler system. I I New dry-pipe,pre-action sprinkler system. Piping System design,installation,and certification. U System Description: Modify existing system and install new components as required to provide coverage for entire building.Provide Y'+•1 system to NFPA-13,of applicable hazard classifications for areas protected. I 5 I I New nitrogen supervised,dry-pipe,pre-action sprinkler system including releasing control panel for Data Center and UPS Room. Control panel to alarm to existing fire alarm panel. Include low supervision pressure,tamper I I 1 I�1 switch alorms,flow alarm. Determine volume and pressure of incoming water supply from water flow test data. Interface system with building control and fire and smoke alarm systems. I I 40 `•r/ Jurisdictional Authority: ` I I -----------------------------•---- ------------------� Idaho State Fire Marshal Mark Larson,208-334-4370. o - ----------------------- ---•---"--- - -_-_-_-----'- - --- - -I"-------_---_ City of Twin Falls Fire Department;Rex Chompneys,208-735-7232. I I Owner's Insurance Representative;FM Global,Art Garcia 972-731-1637,fax 972-731-1811,email ort.garciaefmglobol.com - Cie Acceptable Contractors:Subject to compliance with requirements,the following contractors are approved to bid: Shilo Automatic Sprinkler,Inc.;Randy Knutson 208-442-0007. TT Treasure Volley Fire Protection Ron Stenquist,208-362-1888. 1 W Grinnell Fire Protection;Rick Schlorboum,208-887-1221. MATERIALS Sprinkler Heads: Suspended Ceiling:Semi-recessed pendant type with push-on escutcheon plots. Chrome plated finish. Exposed Area Type:Standard upright type with guard where damage could occur such as in mechanical rooms. V Head finish:Bross. •• I �� I Sidewall Type:Standard horizontal sidewall type with matching push-on escutcheon plate and guard as required. Chrome-plated finish. O �� f I I ao5 O W Above Ground Piping: I/y� Sprinkler piping above ground sholl be Schedule 40,Dyne Thread or equal black steel pipe with a corrosion I I I I. resistance rating squalor greater than 1.0. Sprinkler piping above ground for sizes 2-1/2 inch and larger may be Schedule 1O,Dyna Flow or equalblack steel 4Q5 E pipe. Fittings for threaded and coupled pipe shall consist of cost iron or malleable threaded fittings joined with Teflon tape -._-_-- thread sealing compound or pipe joint compound. Pressure rating of fittings shallbe as required for application. O W Fittings for grooved end pipe shollconsist of Central Sprink or equalcoupiings and fittings in accordance with NFPA-13. Fittings for plain end pipe shall consist of Victoulic or equal couplings,fittings,"Fits and Snop-Lets"'in accordance a with NFPA-13. EXECUTION I I O Installpiping in accordance with NFPA-13 for sprinkler systems. Contractor shollverify site water pressure before - 40 submitting shop drawings to the authorities having jurisdiction for review. ® - j U O Run water bearing pipe in heated spaces. I I i 40.5 E I^1 System piping shollbe hydraulically calculated in accordance with NFPA-13. --- -"---"-•---"-_-"- -" ------------�----•------------ ---_-•_•---------jl-----•---------- - ----_•-- - -- - ---------------- Y'•�1 Provide sprinkler system design for occupancies listed on architectural drawings. - - ���t�//•'�)� Provide wet-pipe sprinkler system for conditioned areas. I I W LO Provide nitrogen supervised,dry-pipe pre-oction sprinkler system and controls for Data Center and UPS. I I I (�Il Q0 • I I I I o Install equipment in accordance with manufacturer's instructions. w I I Center heads in two directions in ceiling tile and provide piping offsets as required. Main open office area is open to roof structure. ® 410 I ,I I 3= All piping shall be run concealed wherever possible. Where piping is run exposed,special notation on Contractor's 1 t0 I 1 ❑ e drawings to that effect shall be evident and conspicuous on the drawings. Any piping determined to be a problem shallbe relocated at no cost to the Owner. r I I I 3 Contractor shall complete the fire protection systems ready for operation and occupancy,in all respects. When L system is complete and ready for continuous operation,activate the system for it's intended use. After system has ® I 4 5 been activated for continuous use,the Owner will pay for water charges. 1 Contractor shall tail for inspection and obtain Certificate of Completion end Test from Fire Inspection Bureau under --------- I I whose jurisdiction this installation occurs. ® s S I ®' I ® ❑ 44'ySE f The surface of all piping shall be cleaned and left ready for painting. 1 s s s 4 5 978 Comply with the following as modified by the local jurisdiction: �- I•'I s�4aWYOj Standard for the Installation of Fire Sprinkler Systems,NFPA-13,1999. I /• O �s''t£aF p y,P Uniform Building Code-_1997. i• -O COTT MPO' Uniform Plumbing Code- 2000. - -----•-- ----j---------------------------------------I------ - --- --------- - -- - - ------------------- Uniform MechanlcalCode - 1997. _ _ Uniform Fire Code -1997. �. 1 �° O I O O O 1 O O O O National Electric Code-1999. e'v ... ' In addition,comply with the following: o H a05 �'' 1 O 405 :' 405 CTA JOB NO. Al applicable Local,State and Federal laws. 405 o O O O O I O O AQ O O $ Obtain required permits,plan review and inspections from authorities having jurisdiction. --- --- - - ----- --- ----- - - ------ — -------- ---------------------• ------------ ------- -•-•-•-------- -- O DELLCC I J 4 - - - - - - - - - - - - - - 1 - - - - - •-•- - ----------- - O DRAWN CHECKED - - T - - - - - - - 408 O 1 405 0 40 408 O DIETRK:H MACKAY 405 ® E O I 408 DATE 10 Li ® Q L4 II/05/01 n a0 O ® - - - - - - - - - - - - ----- - - - - - - - OO SHEET TITLE aos 4b8!i 405 - ————- -------- ❑ F IRE PROTECTION w - _ 1"f _ ROTECTIO o o o 0 4a6 0 "' o f o o i i O PLAN iI - - - - - - - - - - - - - - - - - - - - ------------------------------------------- - - - - - - ------------ - -- - - - - - - - - - - - - - - - - - - - -• - - - - - - - - - - - - - - - O SHEET OFFICE MEZZANINE PLAN ZMQ �NE FPmI SCALE:Ye"=I'-0" .. i i i i FIRE PROTECTION PLAN Rol SCALE�,:,,_o, NORTH SCHEDULE OF AIR CONDITIONING EQUIPMENT DIVISION 15 GENERAL REGULATORY REQUIREMENTS,GENERAL REFRIGERANT PIPING PACKAGE ROOFTOP AIR CONDITIONING UNITS Construct the building systems in fullcomplionce with allopplicoble local Copper Tubing:ASTM 8280,Type ACR,drawn-temper with wrought copper fittings (CONTRACTOR TO BE AWARE THAT UNIT VOLTAGE VARIES FOR.SCHEDULED EQUIPMENT.) building,codes,latest edition.,Comply with the following as modified by the and brazed joints. Use AWS A5.8,BAg-1 silver brozing filler metals. eLEFT REAR (EXISTING) local jurisdiction . LENNOX -16-3003-47(5-36,LENNOX REMDI6M-300-1 ECONOMIZER,TOTAL COOLING CAPACITY 284 MBH. SENSIBLE Uniform Building Code - 1997. O (n V) 5=W 1 COOLING CAPACITY: 190.3 MBH AT 80 DEGREES R.A. 67 DEGREES F EWB,95 DEGREES OSA 10,250 CFM AT 1.0"EXTERNAL Uniform Plumbing Code - 2000. SEQUENCE OF OPERATION (=) W O y STATIC PRESSURE AT SEA LEVEL.NATURAL GAS:INPIjT-470 MBH OUT PUT MBH.ELECTRICAL DATA 460 VOLT, Uniform Mechanical Code - 1997. 3 PHASE,60 HZ:(2)COMPRESSORS AT 22.2 AMP EA.,INDOOR PAN-11.0 AMP,(2)OUTDOOR FANS-2.4 AMP EA. EXHAUST Uniform Fire Code - 1997. SUPPLY - FAN 0.71 AMP,COMBUSTION AIR FAN 0.6 AMPS. MINIMUM CIRCUIT AMP 71.MAXIMUM FUSE SIZE 90 AMP.REPLACE LEAKING SUCTION Notional Electric Code - 1999. GENERAL C=7 Q I-LLJ I-f LINE AND/OR FITTINGS ON STAGE ONE COOLING. REPAIR LIQUID LINE ON STAGE TWO. VACUUM CLEAN PLENUM, In addition,comply with the followings Sequence of operation is defined as the manner and method by which controls ��--). Z V AIR FILTER SECTION AND BLOWER WHEEL. STEAM CLEAN EVAPORATOR COILS,CONDENSER COILS AND DRAIN PAN. � function. Re opements for each t y p p "'_(� N LUBRICATE ALL BEARINGS ON REUSED COMPONENTS AND INSTALL NEW DRIVE BELTS. RECHARGE REFRIGERATION The latest version of the Americans with Disabilities Act Guidelines and the q ype of controls stem o eration are s ecified CIRCUITS. CLEAN BURNERS AND ADJUST FOR PROPER OPERATION. CLEAN CONTROL AND COMPRESSOR COMPARTMENTS. Uniform Federal Accessibility Standard,whichever is more stringent. in this Section. Contractor to suit the unique aspects of the building/Owner - � - U N,n All applicable`Local,State and Federal laws. requirements. O p-/W N FLEXIBLE DUCT SHALL INSTALL NEW FILTERS,FIELD VERIFY SIZE PRIOR TO ORDERING.SET SUPPLY FAN FOR CONTINUOUS OPERATION. Obtain required permits,plan review and inspections from authorities having U Q UZ NOT EXCEED 6'-O"IN INSTALL.NEW HAIL GUARDS. PROVIDE NEW CARRIER MODEL'33CS250-FS FULLY PROGRAMMABLE THERMOSTAT WITH 9 S j MATERIALS (Not Applicable) min= TYPICAL DUCT SHEET METAL LENGTH LOCKING COVER AND CONTINUOUS FAN OPERATION. SEE 1/M301 FOR SETPOINT TEMPERATURE AND LOCATION. urisdiction. VOLUME DAMPER DUCT AND ELBOW RIGHT REAR (EXISTING) ' - BASIC MECHANICAL REQUIREMENTS EXECUTION SQUARE TO ROUND COOLING GCS-16-30: 196 M8H T 80 D REMD1GREES M A 67 ECONOMIZER,TOTAL COOLING CAPACITY 284 MBH. SENSIBLE GENERAL Package Rooftop,Air Conditioning Units Control Sequences:Sequences shall be TRANSITION,WHERE COOLING CAPACITY: S MBH AT.N DEGREES R.A. 67 DEGREES F EWB 95 DEGREES EOSACT 10 250 CFM AT LO"EXTERNAL generated to maintain the building's environmental requirements. Allselpoints REVISIONS METAL DUCT STATIC PRESSURE AT SEA LEVEL.NATURAL GAS:INPUT-470 MBH,OUTPUY-376 MBH.ELECTRICAL DATA:460 VOLT, Scope: and settings shollbe adjustable to suit the Owner's specific requirements TYPICAL DUCT REQUIRED 3 PHASE 60 HZ:(2)COMPRESSORS AT 22.2 AMP,INDOOR FAN-11.0 AMP,(2)OUTDOOR FANS-2.4 AMP EA.,EXHAUST The Contractor shall,installond coordinate all mechanical work to provide should they differ from those outlined below. Industry standards for energ MOUNTED DIFFUSER FAN 0.71 AMP,COMBUSTION AIR FAN 0.6 AMPS. MINIMUM CIRCUIT AMP 71 MAXIMUM FUSE SIZE 90 AMP.VACUUM CLEAN PLENUM, y (CD 2) _--METAL DUCT:CONNECTED FILTER SECTION AND BLOWER WHEEL. STEAM CLEAN EVAPORATOR COILS CONDENSER COILS AND DRAIN PAN. complete and operational mechanical installations. Supply and installcomplete efficiency shallbe utilized to generate sequences in time scheduling and night, TO "SQUARE TO ROUND" LUBRICATE ALL BEARINGS ON REUSED COMPONENTS AND INSTALL NEW DRIVE BELTS. RECHARGE REFRIGERATION mechanical systems throughout to complete project for mechanical systems set back functions. Building Occupied period is 5:00 am thru 3:00 am. Provide ON TOP OF DAMPER CIRCUITS. CLEAN BURNERS AND ADJUST FOR PROPER OPERATION. CLEAN CONTROL AND COMPRESSOR COMPARTMENTS. described herein and indicated on drawings. Drawings are in-part diogrammotic. 2-stages of heating and 2-stages,of mechanical cooling,provide economizer when AiliIiiiiiiioutdoor conditions are suitable using supply-air temperature as a setpoint. INSTALL NEW FILTERS,FIELD VERIFY SIZE PRIOR ER ORDERING.SET SUPPLY FAN FOR CONTINUOUS OPERATION. EXECUTION Provide heotin /coolin s ace temperature sensor with 1-hour unoccupied INSTALL NEW HAIL GUARDS.FIELD VERIFY THE OPERATION OF UNIT ECONOMIZER CONTROLS.THE LAST REMODEL 9 9 P P pied override ------------ "T"-BAR CEILING WITH INCLUDED DISABLING OF ECONOMIZER CONTROLS.PROVIDE CONTROL COMPONENTS REQUIRED TO ENABLE ECONOMIZER capability. SUPPORT BY GENERAL CONTROLS AGAIN.REBALANCE TO OSA QUANTITY AS NOTED ON FLOOR PLAN.REPLACE OUTSIDE AIR INTAKE FILTERS. Install all equipment,accessories and specialties according to manufacturer's )))))),l� NOTIFY ENGINEER OF REPAIRS NEEDED BEYOND THE SCOPE OF THIS PROJECT FOR FURTHER DIRECTION. PROVIDE NEW written instructions. Occupied mode:Within occupied mode,the system may enter warm-up mode when CONTRACTOR (TYPICAL) Interior Coordination The ceiling space shall be layered with a sprinkler spot: temperature is below set point or cool-dawn mode when space temperature is CEILING DIFFUSER UM EXHAUST/ CARRIER MODEL SETPOINT T FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND CONTINUOUS FAN OPERATION. n zone near the underside of the structure,with the HVAC duct zone above set point. Maintain minimum outdoor air control throw h cfm RETURN GRILLE:ALUMINUM,LAY-IN SEE 1/M301 FOR SETPOINT TEMPERATURE AND LOCATION. immediately below.HVAC and plumbing pi ing in the middle,cable measurement. Provide 1007-moduloted economizer cooling as,first stage cooling. LEFT FRONT (EXISTING) trays/conduits above lighting,and the lighting zone immediately above the Provide activation of condensing unit stages contralto maintain 4-5 deg F LENNOX GCS-16-3003-470-36,LENNOX REM016M-300-1 ECONOMIZER,TOTAL COOLING CAPACITY 284 MBH. SENSIBLE ceiling. Provide 6 inch minimum clear space to allow the relocation of light deadbond on the supply air temperature. Also provide time delays to prevent COOLING CAPACITY: 196 MBH AT 80 DEGREES R.A. 67 DEGREES F EWB 95 DEGREES OSA 10 250 CFM AT 1.0"EXTERNAL fixtures cycling. In heating mode,modulate heating stages to maintain discharge air STATIC PRESSURE AT SEA LEVEL.NATURAL GAS:INPUT-470 MBH OUTPUY-376 MBH.ELECTRICAL DATA:460 VOLT, temperature. DUCT MOUNTED DIFFUSER DETAIL 2 TYPICAL CEILING INCS DIFFUSER DETAIL 3 PHASE 60 HZ:(2)COMPRESSORS AT 22.2 AMP,INDOOR FAN-jTO AMP,(2)OUTDOOR FANS-2.4 AMP EA.,EXHAUST HVAC EQUIPMENT,ACCESSORIES AND SPECIALTIES In the building's central space,the,contractor shall stagger the setpoint temperatures FAN 0.71 AMP,COMBUSTION AIR FAN 0.6 AMPS. MINIMUM CIRCUIT AMP 71 MAXIMUM FUSE SIZE 90 AMP.VACUUM CLEAN PLENUM, GENERAL of the Packagge Rooftop Air Conditioning.Units to direct the(2)new 48 Ton Package M701 NOT TO SCALE M101 NOT TO SCALE FILTER SECTION AND BLOWER WHEEL. STEAM CLEAN EVAPORATOR COILS CONDENSER COILS AND DRAIN PAN. Rooftop Air Conditionin,Units to maintain the majority of the space's environmental LUBRICATE ALL BEARINGS ON REUSED COMPONENTS AND INSTALL NEW DRIVE BELTS. RECHARGE REFRIGERATION Section Includes: requirements.The (3)1 Ton units shall begin to operate only when the (2) n Ton CIRCUITS. CLEAN BURNERS AND ADJUST FOR PROPER OPERATION. CLEAN CONTROL AND COMPRESSOR COMPARTMENTS. Packagge rooftop air conditioning units. units failto meet the space's demand. The fans on all Pockage Rooftop Air Conditioning INSTALL NEW HAIL GUARDS. VERIFY SIZE PRIOR ER ORDTION OF UNIT SUPPLY FAN FOR CONTINUOUS OPERATION. Centrifugalroof ventilators and accessories. Units shallrun continuously regardless. INSTALL NEW HAIL GUARDS.FIELD VERIFY THE OPERATION OF UNIT ECONOMIZER CONTROLS.THE LAST REMODEL INCLUDED DISABLING OF ECONOMIZER CONTROLS.PROVIDE CONTROL COMPONENTS REQUIRED TO ENABLE ECONOMIZER MATERIALS Unoccupied mode:Outside air dampers modulate closed to outdoor air. SHEETMETAL RETURN CONTROLS AGAIN.REBALANCE TO OSA QUANTITY AS NOTED ON FLOOR PLAN.REPLACE OUTSIDE AIR INTAKE FILTERS. OPENING IN TOP SHEETMETAL RETURN NOTIFY ENGINEER OF REPAIRS NEEDED BEYOND THE SCOPE OF THIS PROJECT FOR FURTHER DIRECTION. PROVIDE NEW Night heating mode Unit modulates to maintain minimum space temperature of 65 BOOT W/ 1"ACOUSTIC BOOT W/ 1" ACOUSTIC CARRIER MODEL 33CS250-FS FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND CONTINUOUS FAN OPERATION. Manufacturers: Subject to compliance with requirements,provide products by one deg F. 11 LINING. COAT CUT EDGES--,", LINING. COAT CUT EDGES. of the following: Night cooling mode:Unit modulates to maintain maximum space temperature of 80 q RIGHT FRONT (EXISTING) Package Rooftop Air Conditioning Units: deg F. � e LENNOX GCS-16-3003-470-36,LENNOX REMDI6M-300-1 ECONOMIZER,TOTAL COOLING CAPACITY 284 MBH. SENSIBLE Carrier Corp. Safety mode:The following alarms shall deactivate supply fans:smoke detection. r°£' COOLING CAPACITY: 196 MBH AT 80 DEGREES R.A. 67 DEGREES F EWB,95 DEGREES OSA 10,250 CFM AT 1 0"EXTERNAL Lennox Industries,Inc. j l III II j11;, II rA° 6�='il it u 1� i 11 ail'^''YI x' flhii�.l ^Ty litliw1 fIh �' Trane Co. Exhaust Fan Control:All building exhaust fans shall continuously. i fGI IIuINIi(�1 rX pI II�I�II Ig kl�,kI�ql� ��'III VIJII W I' �61 Ptll Iq IW,I Ii It p STATIC PRESSURE AT SEA LEVEL.NATURAL GAS:.INPUT-470 MBH OUTPUT-376 MBH.ELECT121CAL DATA:460 VOLT, y i,ajj)1 III' _ Illyt it AEI"" 1 eIi kk�i 1, .t 5 �h, )I II III aIi ;.. 3 PHASE.60 HZ:(2)COMPRESSORS AT 22.2 AMP,INDOOR FAN.-I1.0 AMP,(2)OUTDOOR FANS-2.4 AMP EA.,EXHAUST f 161 "Il rill k' ` 1 h 4 li q l II li, ",1:III 1Y III n;,l I, I ly uM I; kl d y ii FAN 0.71 AMP COMBUSTION AIR FAN 0.6 AMPS:.MINIMUM CIRCUIT AMP 71 MAXIMUM FUSE SIZE 90 AMP.VACUUM CLEAN Centrifugal Roof Ventilators: TESTING,ADJUSTING AND BALANCING td� ) n II �"k"� I N m i 4 i In )4 M' � @ PLENUM,FILTER SECTION AND BLOWER WHEEL. STEAM CLEAN EVAPORATOR COILS,CONDENSER COILS AND DRAIN PAN. Cook. Greenheck. GENERAL�IIII L.Wt I@�,IF�„"N ) III N�1p'x a'Fi.. ii6'Ir III S,!I",v` � IO rya �i.'. LUBRICATE ALL BEARINGS ON REUSED COMPONENTS AND INSTALL NEW DRIVE BELTS. RECHARGE REFRIGERATION Penn Ventilator ° fi II I"+Jr� `I 1t CIRCUITS. CLEAN BURNERS AND ADJUST FOR PROPER OPERATION. CLEAN CONTROL AND COMPRESSOR COMPARTMENTS. Section Includes: INSTALL NEW FILTERS,FIELD VERIFY SIZE PRIOR TO ORDERING.SET SUPPLY FAN FOR CONTINUOUS OPERATION. Package Rooftop Air Conditioning Units ReqGuirements Provide manufacturer's Testing,adjustment,and balancing of air systems. PLANA INSTALL NEW HAIL GUARDS.FIELD VERIFY THE OPERATION OF UNIT ECONOMIZER CONTROLS,THE LAST REMODEL standard features associated with the me elnumbers scheduled on the drawings. PLAN INCLUDED DISABLING A ECONOMIZER CONTROLS. VIDENOT CONTROL COMPONENTS REQUIRED ID ENABLE ECONOMIZER Provide additional features and components as identified on the drawings. Qualifications: Employthe services of on independent testing,adjusting and CONTROLS AGAIN.REBALANCE TO OSA QUANTITY AS NOTED ON FLOOR PLAN.REPLACE OUTSIDE AIR INTAKE FILTERS. balancing agency; Srvices shollinclude checking installations for conformity NOTIFY ENGINEER OF REPAIRS NEEDED BEYOND THE SCOPE OF THIS PROJECT FOR`FURTHER DIRECTION. PROVIDE NEW Provide a"preliminary product submittal"to Engineer for review prior to final to design objectives,measurement and establishment of the fluid (6)WIRE HANGERS (6)WIRE HANGERS CARRIER MODEL 33C5250-FS FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND CONTINUOUS FAN submittalpracess. This project time schedule re wires coordination and quantities of the mechanical systems. TO STRUCTURE OPERATION. SEE 1/M301 FOR SETPOINT TEMPERATURE AND LOCATION. G DIMENSIONS ARE NET �TO STRUCTURE cooperation between the contractor,owner and design team. (INSIDE LINING) DIMENSIONS ARE NET CONTRACTOR TO CONTACT DAVID DAHL LENNOX FIELD TECH.CONSULTANT AT LENNOX ■ 800.575.3283 Acceptable Agencies:Subject to compliance with requirements,the following TO SCHEDULE ON-SITE VERIFICATION Of'ECONOMIZER OPERATION FOR UNITS LISTED ABOVE. Centrifugal Roof Ventilator Requirements:Provide manufacturer's standard agencies are approved to Bid: NECK (MIN) NECK (INSIDE LINING) NECK 24"(MIN) NECK features associated with the model numbers scheduled on the drawings. Provide Felts-House Engineering,Pot House (208)375-6018;Boise,ID. SIZE SIZE SIZE SIZE - additional features and components as identified on the drawings. Ro-Bar Technical Services,Robert Clarkson or Barry Fitzgerald (208)342-1231; _ € (EXISTING) EXECUTION Boiser ID, €r-0?i 'a ''Ry?,15�III Il l,4 4 II ill n,,,t l N ----'- -----'- ______-i ®5 LENNOX GCS16-1353-270-76,TOTAL COOLING CAPACITY 119 MBH. SENSIBLE COOLING CAPACITY:83.3 MBH AT 80 DEGREES - Flo-Rite,Jon Rice (208)238-8330;Pocatello,ID. 1 � R.A.,67 DEGREES F EWB 95 DEGREES OSA,3,400 CFM AT 0.42' EXTERNAL STATIC PRESSURE AT SEA LEVEL. NATURAL Package Rooftop Air Unit Installation: MATERIALS (Not Applicable) M „ „t.,Il II II j Ila° i�nl' -� i 3 �d,�*d III�Sli GAS: INPUT-270 MBH,OUTPUT-216 MBH.ELECTRICAL DATA:460 VOLT,60 HZ 3 PHASE. (2)COMPRESSORS AT 9.6 AMPS Install according to manufacturer's written installation instructions and actual N r--------� EACH,(2)INDOOR FAN AT 1.2 AMPS EACH,(1)OUTDOOR FAN AT 4.8 AMPS. STEAM CLEAN EVAPORATOR COILS,CONDENSER 1'obsite conditions. Install in accordance with ASHRAE 15. EXECUTION OM u� COILS,AND DRAIN PAN. VACUUM CLEAN BLOWER WHEEL AND PLENUM.LUBRICATE ALL BEARINGS ON REUSED COMPENENTS Supply initial charge of refrigerant and oil for each refrigeration system, M M 1 AND INSTALL NEW DRIVE BELTS. CLEAN BURNERS AND ADJUST FOR PROPER OPERATION. CLEAN CONTROL AND COMPRESSOR Replace losses of of or refrigerant prior to end of correction period. Perform total system balance in accordance with AABC National Standards for 1 COMPARTMENTS. INSTALL NEW FILTERS FIELD VERIFY SIZE PRIOR TO ORDERING.INSTALL NEW HAIL GUARDS.PROVIDE NEW Shut-down system if initial sfort-up and testing takes place in winter and Field Measurement and Instrumentation,Total system Balance ASHRAE 111 or NEBB W M CEILING GRID CEILING GRID CARRIER MODEL 33C5250-FS FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND CONTINUOUS FAN OPERATION. machines are to remain inoperative. Repeat start-up and testing operation at Procedural Standards for Testing,Balancing and Adjusting of knviranmental li' beginning of first cooling season. Systems. w Q M T'S BY OTHERS. RETURN GRILLE LAYS T'S BY OTHERS. Provide a factory authorized start-up service on condensing units to test and / INTO CEILING GRID. ® I IT verify proper operation of controls and safeties. Adjusting: \F-�� Lae SEE PLAN FOR SIZES. RETURN GRILLE LAYS 6 LENNOX HP76-261,TOTAL COOLING CAPACITY 25.1 MBH,SENSIBLE COOLING CAPACITY 20.4 MBH AT 80 DEGREES R.A., Ensure recorded data represents actuolmeasured or observed conditions. (n O INTO CEILING GRID. 67 DEGREES F EWB,95 DEGREES OSA,800 CFM AT 0.42"EXTERNAL STATIC PRESSURE AT SEA LEVEL.10 KW AUXILIARY Centrifugal Roof Ventilator Installation: After ad ustment,take meosurements to verify balance has not been disrupted or N- SEE PLAN FOR SIZES. ELECTRIC HEAT,MODEL NO.ECH16R-10. ELECTRICAL DATA:208 VOLT,60 HZ,1 PHASE,(1)COMPRESSOR AT 11.5 AMPS, Install according to manufacturer's written installation instructions and actual that such disruption has been rectified. /�/, O`-' INDOOR FAN 2.2 AMP,OUTDOOR FAN 1.1 AMP.TOTAL UNIT WITH ELECTRIC HEAT MINIMUM CIRCUIT AMP 54.2.STEAM jobsite conditions. - Leave systems m proper working order,replacing belt wards,closing access Co INSTALLATION IN GYPSUM CLEAN EVAPORATOR COIL,CONDENSER COIL AND DRAIN PAN VACUUM CLEAN BLOWER WHEEL AND PLENUM,LUBRICATE I 1 g �7 1 BOARD CEILING IS SIMILAR SECTION SECTION ALL BEARINGS AND INSTALL NEW DRIVE BELTS.CLEAN CONTROL AND COMPRESSOR COMPARTMENTS,INSTALL NEW FILTERS, doors,c osing doors to electrica switch boxes,and restoring thermostats to �.L+ DUCTS AND DUCT ACCESSORIES specified settings. ILL VERIFY SIZE. PROVIDE NEW CARRIER MODEL 33CS250-FS FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND Balance air system terminals to provide flow rates within • or- 10 percent of TO THIS DETAIL. CONTINUOUS FAN OPERATION. GENERAL those specified I O ® HUDDLE ROOMS (NEW) Section Includes: Adjust air handling and distribution systems to provide required or design O CARRIER MODEL 48HIJF004,TOTAL COOLING CAPACITY 32.6 MBH SENSIBLE COOLING CAPACITY 26.5 MBH AT EAT 84°F OB., supply,return,and exhaust air quantities at site altitude. RETURN/TRANSFER DUCT DETAIL 7 AND 643E WB,99'F OSA,900 CFM AT 0.75"EXTERNAL STATIC PRESSURE.NATURAL GAS INPUT:115 MBH,OUTPUT:73.6 MBH. Rectangular,round and Ilat oval metal ducts for heating,ventilating and air- Vary total system air quantities by adjustment of fan seeds. t 3 ELECTRICAL DATA:208 VOLT,60 HZ,3 PHASE,(1)SCROLL TYPE COMPRESSOR AT 10.3 RLA.INDOOR FAN - 4.9 FLA,(1)OUTDOOR Recta conditioning systems. p Ir�'1 NOT TO SCALE 9 Y Effect system balance with automatic control valves fully open to heat transfer • W M101 FAN 10.7 FLA,COMBUSTION FAN MOTOR -0ND FLA.MINIMUM CIRCUIT AMP 18.5 MAXIMUM OVER-CURRENT PROTECTION - 25 AMP. Backdraft dampers. elements. Controlvalve bypass loops shollbe set with the balancing valve to O GC M PROVIDE INTEGRATED ECONOMIZER HEATING AND COOLING THERMOSTAT WITH AUTOMATIC CHANGE OVER AND SUB-BASE FOR Manuel volume dampers. provide equal flow in either mode. Confirm in writing. � Ce^ FAN CONTROL.INCLUDE THE FOLLOWING ACCESSORIES:BAROMETRIC RELIEF DAMPER PACKAGE HEAD PRESSURE CONTROL Fire,smoke and combination fire/smoke dampers.PACKAGE,LOW-AMBIENT KIT AND 5-MINUTE COMPRESSOR CYCLE DELAY.PROVIDE HINGED ACCPSS PANELS,2"FARR 30/30 Turning vanes. Report of Work: FILTERS,HAIL GUARD AND PRE-FABRICATED ROOF CURB.SEER-13.0.EQUIPMENT WEIGHT 530 LBS.PROVIDE CARRIER MODEL Duct mounted access doors and panels. The TAB Contractor shollsubmit a minimum of four(4)bound copies of the final O LLI co 33C5250-FS FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND CONTINUOUS FAN OPERATION. Diffusers,registers and grilles. testing and balancing report to Owner's Representative prior to building 0 O N ® occupancy.EAKROOM (NEW) MATERIALS Report forms shollbe generated on standard NEBB forms. 8 AR TERM EL 4 HJF008,TOTAL COOLING CAPACITY 85.5 MBH,SENSIBLE COOLING CAPACITY 73.2 MBH AT EAT 813E DB. Final acceptance of this project willnot take place untila satisfactory report C7 LW AND 64-F WB,99-F OSA,3600 CFM AT 0.75"EXTERNAL STATIC PRESSURE.NATURAL GAS INPUT:224 MBH OUTPUT:147.0 Whl. Manufacturers: Sub p q p p y ELECTRICAL DATA:208 VOLT,60 HZ,3 PHASE,(2)SCROLL TYPE COMPRESSOR AT 12.4 RLA(EA.).INDOOR FAN - 7.5 FLA,(2)OUTDOOR of the following: Jett to compliance with requirements,provide products b one Report Report shall bear signature of test and balance engineers or Un O FAN - 1.4 FLA(EA.) COMBUSTION FAN MOTOR -0.57 FLA.MINIMUM CIRCUIT AMP 38.2,MAXIMUM OVER-CURRENT PROTECTION - 45 AMP. C� co Diffusers,Registers and Grilles: technlcion. The Reports shall be certified proof that the systems hove been O=. PROVIDE INTEG NCL D ECONOMIZER,HEATING AND COOLING THERMOSTAT WITH AUTOMATIC CHANGE OVER AND SUB-BASE FOR Price. balanced in accordance with NEBB standards. FAN CONTROL.INCLUDE THE FOLLOWING ACCESSORIES:BAROMETRIC RELIEF DAMPER PACKAGE HEAD PRESSURE CONTROL Krueger. A reduced set of contract document drawing indicating'cs-built'conditions PACKAGE,AIL GUARD A KIT AND BRICA E COMPRESSOR CYCLE DELAY,PROVIDE HINGED ACCPSS PANELS,2"FARRCARRIER 3ODEL Titus/Tuttle&Bo1ey. shollbe included in the report with oll terminals(outlets inlets,etc.)and /1 /'� FILTERS HAIL GUARD AND PRE-FABRICATED ROOF CURB.SEER LOCKING EQUIPMENT WEIGHT OUS LBS. PROVIDE CARRIER MODEL thermostat locations clearly marked and all equipment designated. C ) V J 33CS256-FS FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND CONTINUOUS FAN OPERATION. Sheet Metal Duct Reqauirements:Galvanized Sheet Steel:Lock-forming quality, ZEN NORTH TRAINING OOM (NEW) ASTM A 653/A653fd,G90 coating designation,mill-phosphalized finish for surfaces 1�1 of ducts exposed to view. CARRIER MOD L 4 HJ 14,T AL COOLING CAPACITY 132.7 MBH,SENSIBLE COOLING CAPACITY 1075 MBH AT EAT 803E DB. Reinforcement Shapes and Plates: VENT DISCHARGE VENT CAP,BIRD PROOF AND 643E W8,99°F OSA,4800 CFM AT 0.75"EXTERNAL STATIC PRESSURE.NATURAL GAS INPUT:250 MBH OUTPUT:160.0 MbH. Galvanized steelreoforcement where installed on galvanized sheet metal ducts. A MINIMUM OF 48" ELECTRICAL DATA:460 VOLT 60 HZ 3 PHASE,(2)SCROLL TYPE COMPRESSOR AT 9.0 RLA(EA.).INDOOR FAN - 7.4 FLA (2)OUTDOOR Tie Rods:Galvanized steel)1/4 inch minimum diameter for 36 inch length or ABOVE THE ROOF,OR FAN - 0.7 FLA<EA.) COMBUSTION FAN MOTOR -0.30 FLA.MINIMUM CIRCUIT AMP 35,MAXIMUM OVER-CURRENT PROTECTION - 35 AMP. less:3/8 inch minimum diameter for lengths longer than 36 inches. 48"ABOVE ANY PARAPET FIOOzstend �---"-- PROVIDE INTEGRATED ECONOMIZER,HEATING AND COOLING THERMOSTAT WITH AUTOMATIC CHANGE OVER AND SUB-BASE FOR Sealant Materials:Pressure sensitive duct tape is not acceptable. Tope sealing OR FRESH AIR INTAKE GAS VENT:TYPE "B"UL FAN CONTROL.INCLUDE THE FOLLOWING ACCESSORIES:BAROMETRIC RELIEF DAMPER PACKAGE HEAD PRESSURE CONTROL system:Woven fiber tape impregnated with a gypsum mineralcompound and o C `J WITHIN 10 FEET APPROVED FOR 1"CLEARANCE PACKAGE,LOW-AMBIENT KIT AND 5-MINUTE COMPRESSOR CYCLE DELAY.PROVIDE HINGED ACCESS PANELS 2"FARR 30/30 modified acrylic/silicone activator to react exothermically with tape to form a v I 1 FROM COMBUSTIBLES. �'T�- FILTERS HAIL GUARD AND PRE-FABRICATED ROOF CURB.SEER-9.9.EQUIPMENT WEIGHT 1 050 LBS. PROVIDE CARRIER MODEL hard,durable,airtight seal. Joint and Seam Sealant:One part,non-sag, l-� U. 1 : 33CS25b-FS FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND CONTINUOUS FAN OPERATION. solvent-release-curing,polymerized butyl sealant,formulated with a minimum of 1 I 75 percent solids. STORM COLLAR I I Flan ed Joint Mastics:One art,acid curing,silicone,elastomeric joint 1 I ® DATA CENTER INDOOR AIR-CONDITIONING UNIT (PROVID D BY OWNER INSTALLED BY CONTRACTOR)(NEW) 9 p I i 10 LIEBERT MODEL DH290A-AAEI ()WNFLOW.TOTAL COOLING CAPACITY 248.4 MBH,SENSIBLE COOLING CAPACITY 224.8 MBH AT EAT 723E DB., sealants,complying with ASTM C920,Type S,Grade NS,Class 25,Use 0. h.H ROUND,STANDING 1 I SEAL WEATHER-TIGHT WITH "O.. AND 643E WB,12,000 CFM AY 0.5"EXTERNAL STATIC PRESSURE.ELECTRICAL DATA:460 VOLT,60 HZ,3 PHASE 70.0 FLA,7.5 HP.ELECTRIC Rectangular Duet Fabrication:Fabricate ducts elbows,transitions offsets COLLAR,4"HIGH i i REHEAT CAPACITY:30 KW,INFARED HUMIDIFIER CAPACITY:9.6 KW.INCLUDES THE FOLLOWING OPTIONS:LOCKING DISCONNECT SWITCH, branch connectionsand other construction with galvanized sheet steel,accordin 1 "PAR-BOND"GUTTER SEAL \,��' FIRE-STAT,CONDENSATE PUMP,AND REMOTE TEMPERATURE / HUMIDITY SENSOR.EQUIPMENT WEIGHT 2,085 LBS. 9 g, CURB CAP:22 GAGE I I SOLDER STANDING COLLAR .�11 to SMACNAs 'HVAC Duct Construction Standards--Metal and Flexible." Comply with U CROSS BREAK TOP & E RTH CONFRENCE ROOM (NEW) requirements for metal thickness,reinforcing types and intervals,tie-rod TO CAP & SEAL WEATHER-TIGHT applications and joint types and intervals. Fabricote ducts in lengths SOLDER ALL JOINTS 11 CARRIER M L 18HJF004,TOTAL COOLING CAPACITY 35.2 MBH,SENSIBLE COOLING CAPACITY 32.2 MBH AT EAT 833E DB., E.._( AND 64-F WB,99°F OSA 1,100 CFM AT 0.75"EXTERNAL STATIC PRESSURE.NATURAL GAS INPUT:115 MBH,OUTPUT:73.6 MBH, appropriate to reinforcement and rigidity class required for pressure 1 PRE-FABRICATED I I '\`".� /� ELECTRICAL DATA:208 VOLT,60 HZ,3 PHASE,(1)SCROLL TYPE COMPRESSOR AT 10.3 RLA.INDOOR FAN - 4.9 FLA,(1)OUTDOOR classification. Use materials that ore free from visual imperfections such as CURB.RE:5.OB-22 2"1 I FLASHING:3",FASTEN TO I -/''D FAN - 0.7 FLA COMBUSTION FAN MOTOR -0.57 FLA.MINIMUM CIRCUIT AMP 18.5 MAXIMUM OVER-CURRENT PROTECTION - 25 AMP. pitting,seam marks,roller marks,stains and discolorations. r^ I I CURB (2)PLACES EACH SIDE / -� PROVIDE INTEGRATED ECONOMIZER HEATING AND COOLING THERMOSTAT WITH AUTOMATIC CHANGE OVER AND SUB-BASE FOR Static Pressure Classifications:Construct ducts to the following: \\\ FAN CONTROL.INCLUDE THE FOLLOWING ACCESSORIES:BAROMETRIC RELIEF DAMPER PACKAGE HEAD PRESSURE CONTROL g: '�- : -`-• PACKAGE,LOW-AMBIENT KIT AND 5-MINUTE COMPRESSOR CYCLE DELAY.PROVIDE HINGED ACCI=SS PANELS 2"FARR 30/30 Supply Ducts:3-inch wg. I I FILTERS HAIL GUARD AND PRE-FABRICATED ROOF CURB.SEER-13.0.EQUIPMENT WEIGHT 530 LBS. PROVIDE CARRIER MODEL Return Ducts:2-inch wg,negative pressure. STEEL FABRICATOR TO CONSTRUCT 33CS256-FS FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND CONTINUOUS FAN OPERATION. Exhaust Ducts:2-inch wg,negative pressure. LU FLOORSTAND 18"IN HEIGHT FOR Cross Breaking or Cross Beading:Cross break or cross bead duct sides 19 inches LLJ SUPPORT WEIGHT OF GAS VENT 2,000 LB.LIEBERT UNIT,PRIME AND ® WEST TRAINNG ROOM (NEW) and larger and 0.0359 inch thick or less,with more than 10 sq.ft.of unbraced FROM STRUCTURE PAINT BLACK.HVAC CONTRACTOR CARRIER MODEL 48HJD017 T TAL COOLING CAPACITY 173.7 MBH,SENSIBLE COOLING CAPACITY 138.1 MBH AT EAT 80-F OB., and l area,unless ducts ore lined. TO PROVIDE DIMENSIONS "E"14 "D" 12 AND R! 64°F WEI,99°F OSA,ti300 CFM AT 0.75"EXTERNAL STATIC PRESSURE.NATURAL GAS INPUT:275 MBH,OUTPUT:178.2 MBH. Elbows shall be 1.5 radius construction unless space does not permit,in which ELECTRICAL DATA:460 VOLT 60 HZ 3 PHASE,(2)SCROLL TYPE COMPRESSOR AT 14.1 RLA(EA.).INDOOR FAN - 7.9 FLA (3)OUTDOOR case mitered elbows shollbe used. All elbows shall have turning vanes. O FAN - 0.8 FLA(EA.),COMBUSTION FAN MOTOR -0.30 FLA.MINIMUM CIRCUIT AMP 42,MAXIMUM OVER-CURRENT PROTECTIbN - 50 AMP. U PROVIDE INTEGRATED ECONOMIZER HEATING AND COOLING THERMOSTAT WITH AUTOMATIC CHANGE OVER AND SUB-BASE FOR Round and Flat Oval Duct Fabrication: Round Transverse Joints:Duct-to-duct V FAN CONTROL.INCLUDE THE FOLLOWING ACCESSORIES:BAROMETRIC RELIEF DAMPER PACKAGE HEAD PRESSURE CONTROL joints up to 36_inch diameter shollbe formed with o slip coupling that fits U PACKAGE,LOW-AMBIENT KIT AND 5-MINUTE COMPRESSOR CYCLE DELAY.PROVIDE HINGED ACCESS PANELS 2"FARR 30/30 Inside both noting duct sections,with a minimum 2 inch insertion length and a \ 7 GAS VENT DETAIL FILTERS HAIL GUARD AND PRE-FABRICATED ROOF CURB.SEER-13.0.EQUIPMENT WEIGHT 2,050 LBS. PROVIDE CARRIER MODEL 9 L a 5 LIEBERT INDOOR UNIT FLOORSTANO SUPPORT 33CS256-FS FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND CONTINUOUS FAN OPERATION. stop bead. Ducts larger than 36-inch diameter shollhove a flanged gosketed O joint with externalclosure band. M101 NOT TO SCALE M101 NOT TO SCALE ® WEST CONFERENCE ROOM (NEW) UJ 13 CARRIER MODEL 48HJ SA,1,TOTAL COOLING CAPACITY 35.2 MBH,SENSIBLE COOLING CAPACITY T:11 MBH AT EAT 833E D B Flat formed Transverse upping:Duct-its inside joints up mating 24 inch diameter shollbe AND 643E WB,99°F 8 V LT.6 CFM AT 0.SE,EXTERNAL STATIC PRESSURE.NATURAL GAS INPUT:115 MBH,OUTPUT:(1)O MBH, minimeumWl2 inthvinserrtloln length hand ia9istob bead aDuctsutat sections,with a w M ELECTRICAL DATA:MB VION FA HZ.3 PHASE,(D SCROLL TYPE COMPRESSOR AT MAXIMUM RLA.INDOOR FAN - 4.9 FLA,(D OUTDOOR 9 t ger than . inch i°+-1 �/) FAN -0.7 FLA COMBUSTION FAN MOTOR -0.57 FLA MINIMUM CIRCUIT AMP 18.5 MAXIMUM OVER-CURRENT PROTECTION - 25 AMP. diameter shall have a flanged gosketed join with externalclosure band. � V I PROVIDE INTEGRATED ECONOMIZER HEATING AND COOLING THERMOSTAT WITH AUTOMATIC CHANGE OVER AND SUB-BASE FOR Round Ducts:Fabricate ducts,elbows,transitions,offsets branch connections W :-- FAN CONTROL.INCLUDE THE FOLLOWING ACCESSORIES:BAROMETRIC RELIEF DAMPER PACKAGE HEAD PRESSURE CONTROL PACKAGE,LOW-AMBIENT KIT AND 5-MINUTE COMPRESSOR CYCLE DELAY.PROVIDE HINGED ACCPSS PANELS,2"FARR 30/30 and other construction of galvanized steeloccording to SMACNA's "HVAC Duct FILTERS HAIL GUARD AND PREFABRICATED ROOF CURB.SEER-13.0.EQUIPMENT WEIGHT 530 LBS. PROVIDE CARRIER MODEL Construction Standords--Metal and Flexible." 33CS256-FS FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND CONTINUOUS FAN OPERATION. Flat OvolDucts:Fabricate ducts,elbows,transitions,offsets,branch ^ L I connections and other construction with standard spiral lock seams or with butt- �..L� �'N W OOFTP UNITS MAIN GALLERY (NEW) welded longitudinal seams according to SMACNA's "HVAC Duct Construction AC-14 AND 15 t4 15 CARRIER MOD L� 45SEJ b48,TOTAL COOLING CAPACITY 503.0 MBH,SENSIBLE COOLING CAPACITY 333.4 MBH AT EAT 80°F DB. Standards--Metaland Flexible." AND 64-F WB,99-F OSA 16 000 CFM AT 0.75"EXTERNAL STATIC PRESSURE.NATURAL GAS INPUT:400 MBH,OUTPUT:262.4 MDH. TRANSITION DUCT TO ELECTRICAL DATA:460 VOLt 60 HZ,3 PHASE,(2)SCROLL TYPE COMPRESSOR,(1)COMPRESSOR AT 42.3 RLA,(1)COMPRESSOR AT Elbows shollbe 1.5 radius construction unless space does not permit,in which T UNIT CONNECTION 28.8 FLA.INDOOR FAN - 34.6 FLA,(4)OUTDOOR FAN - 2.7 FLA(EA.),COMBUSTION FAN MOTOR -0.50 FLA.MINIMUM CIRCUIT AMP 11.5 case mitered elbows shall be used. O ,- SIZE,ATTACH DUCT MAXIMUM OVER-CURRENT PROTECTION - 150 AMP.PROVIDE GEAR DRIVEN INTEGRATED ECONOMIZER HEATING AND COOLING THERMOSTAY TO UNIT WITH AUTOMATIC CHANGE OVER AND SUB-BASE FOR FAN CONTROL.INCLUDE THE FOLLOWING ACCESSORIES:BAROMETRIC RELIEF Round Takeoffs From Rectangular Ducts:Provide factory-fabricated,high- DAMPER PACKAGE,HEAD PRESSURE CONTROL PACKAGE,LOW-AMBIENT KIT AND 5-MINUTE COMPRESSOR CYCLE DELAY.PROVIDE efficiency fittings with a rectangular opening in the main duct,45 degree PROVIDE VIBRATION HINGED ACCESS PANELS,2"FARR 30/30 FILTERS HAIL n/ GUARD AND PRE-FABRICATED ROOF CURB.SEER-8.5.EQUIPMENT WEIGHT square-to-round transition and a single blode damper with locking quodrant in O ISOLATION PADS 6,334 LBS. PROVIDE CARRIER MODEL 33CS250-FS FULLY PROGRAMMABLE THERMOSTAT WITH LOCKING COVER AND CONTINUOUS the round connection. r.r. BETWEEN UNIT BASE - FAN OPERATION. /// RAIL AND SUPPORTING _ Manual Volume Dampers:Factory fabricated with required hardware and STEEL ® NR COOLED CONDENSER DATA_,Cf TER (PR01,(,IDED BY OWNER.INSTALLED BY CONTRACTOR)(NEW) accessories. Stiffen damper blades for stability; Include linking device to 1 LIEBERT MOOEL�GDF415L 1 SF u 13N AMBIENT TE�TU OUIPM N W I H 815 L S. hold single blade dampers in a fixed position without vibration..Close duct NEW STEEL SUPPORT ULTRA-VIOLET rnelraftons for damper components to seolduct consistent with pressure class. ^+ BY STEEL FABRICATOR. RESISTANT FLEX FURNACES Provide single blade In round and rectangular ducts when dimensions are less _ ` HVAC CONTRACTOR CONNECTOR than 12 inch. Larger sizes use multiple blades. Use parallel blade style W TO PROVIDE DIMENSIONS ® UNIT NEATER (EXISTING) for mixing application,otherwise use opposed blade design. Dampers shall be TO STEEL FABRICATOR _ _ - _ 1 EXISTING UNIT T I REMAIN. NO WORK REQUIRED UNDER THIS CONTRACT. Usenda lv leakage rating and suitable for horizontal or vertical applications. ^ _^ galvanized steel materials. w Z Fire Dampers:r UNIT HEATER (RELOCATED) p Labeled to UL 555,rated appropriately to correspond with rating LEGEND of partition penetrated. v 2 REZNOR MODEL F Q400 MBH INPUT AND 320 OUTPUT./1HP,7.0 AMP 120 VOLT 60 HZ. EQUIPMENT WEIGHT 276 LBS. Frame:SMACNA Type A with blades in airstream:fabricated from roll-formed i I N FURNISH AND INSTALL NEW ELECTRONIC IGNITION SYSTEM. CLEAN BURNERS AND DRAIN PAN. ADJUST BURNERS FOR galvanized steel;with mitered and interlocking corners. Use Type A in all PROPER OPERATION. LUBRICATE MOTOR AND FAN BEARINGS. REPLACE FAN BELT. medium pressure duct penetrations. SYMBOL ABBREV. DESCRIPTION 1i i1 Frame:SMACNA Tye SHACOU TIC DUCT WITH SUPPLY 4 EXHAUST FANS formed alvanizetl steel;with mitered and interlockingrl tr co corners. fabricated from roll- 1"ACOUSTICAL LINING, in alllocations not covered above. Type B or C SA SUPPLY AIR PROVIDE ROOF CURB SEAL SEAMS AND JOINTS1. 1 i e ROOF EXHAUST FAN (FAX /COPY ROOM)(NEW) RA RETURN AIR F� V. FOR DUCTWORK, 1 1 EXTERIOR OF BUILDING 1 COOK MODEL ACE90C150DM 450 CFM AT 0.375"STATIC PRESSURE:I/eHP,120 VOLT.WITH BACKDRAFT DAMPER,BIRD Smoke Dampers:Labeled to UL 5555,leakage Gloss tat elevated temperatures. ® OSA OUTSIDE AIR ° WATER TIGHT SCREEN AND DISCONNECT SWITCH. Motor/actuator shall assume fail-safe position upon loss of powersion 1de two- FLASHING AND COUNTER 1 i position motor. Coordinate electric service requirements with Division 16 EXHAUST AIR �3r IZI FLASHING FOR DUCT,BY JL i I JL ROOF EXHAUST AN (11P5 ROOM) Contractor. ® EXA HVAC CONTRACTOR I 1 e2 COOK MODEL ACE-812OC28 750 CFM AT 0.5"STATIC PRESSURE;1/6 HP,120 VOLT.WITH BACKCRAFT DAMPER,BIRD Combination Fire/Smoke Dam p p y I SCREEN AND DISCONNECT SWITCH. correspond with rating of partition Lpenetrated.Motor/octuotorasRa/assum@ to ACOUSTIC LINED DUCT 1 EXISITNG ROOF p eROOF EXHAUST FAN (MENS AND WOMENS RESTROOMS)(EXISITNG) fail-safe position upon loss of power and open upon power restoration.Provide 4 GREENH CK MODEL G-120-B,750 CFM AT 0.25"STATIC PRESSURE;1/6 HP,120 VOLT.INSTALL NEW BELT,LUBRICATE two-position motor. Coordinate electric service requirements with Division 16 BRANCH TAKE-OFF L MOTOR AND FAN BEARINGS. Contractor. 4�Sc,AO E. ROOF EXHAUST FAN IEXISITNC) Turning Vanes:Fabricate to comply with SMACNA's "HVAC Duct Construction Imo.Imo. ELBOW WITH TURNING VANES 5 GREENHECK MODEL CUBE-140-5,1,650 CFM AT 1.0"STATIC PRESSURE%zHP,120 VOLT.INSTALL NEW BELT,LUBRICATE Standards--Metaland Flexible." � -+ ��� A QAC-14,AC-15 ROOF CURB DETAIL MOTOR AND FAN BEARINGS. Duct-mounted Access Doors and Panels:Fabricate doors and panels oirti?ht and ,F suitable for duct pressure class, Insulate to match duct insulation. Provide +-�• MVD MANUAL VOLUME DAMPER ,p EgNeJO/ M101 NOT TO SCALE 6 JM RRE-OE NHECK,MODEL XHAUST F �1 CT4%OD RICObO�Cf M 1ATIN 4T�'STATIC PRESSURE:1/qHP,115 VOLT,60 HZ,1 PHASE. size adequate to reset or replace damper linkage. i-4-1 �sr�tf gp A��p INSTALL NEW BELT.LUBRICATE MOTOR AND FAN BEARINGS. ® CD CEILING SUPPLY DIFFUSER EF ROOF EXHAUST FAN (EXISITNG) Supply,Diffusers,Return and Exhaust Grilles:Drawings and schedules indicate COTT MPS' specific requirements of diffusers,registers and grilles and are based on the COOK MODEL 7OC10DM,90 CFM AT 125"STATIC PRESSURE.1/25 HP,120 VOLT,1 PHASE,60 HZ.INSTALL NEW BELT, specific requirements of the systems indicated. Center oll ceiling mounted SR SUPPLY REGISTER LUBRICATE MOTOR AND FAN BEARINGS. fixtures and devices in the ceiling tiles. ROOF EXHAUST FAN (EXISTING) EXECUTION A SG SUPPLY GRILLE CTA JOB NO, \11J 180 CFM AT 0.25"STATIC PRESSURE;1/6 HP,120 VOLT,1 PHASE,60 HZ.INSTALL NEW BELT,LUBRICATE MOTOR AND �e�- RR RETURN REGISTER FAN BEARINGS. Installducts with fewest possible joints,vertical) and horizontal) p j y y,parallel - and perpendicular to building lines. Avoid diagonal runs. Install ducts close to walls,overhead construction,columns and other �- RG RETURN GRILLE DELLCC GRILLES,REGISTERS !DIFFUSER SCHEDULE structural and permanent enclosure elements of building. Where ducts pass through non-fire-rated interior partitions,conceal space ®e-w- ER EXHAUST REGISTER EG ER CEILING MOUNTED - EXHA ST AND RETURN between construction opening and duct with sheet metal flanges of same metal DRAWN CHECKED thickness as duct.Overtop opening on four sides by at least 1-1/2 inches. RR RG L 4'ON CENTER,0 DEGREES DEFLECTION,SET IN FRAMES,REGISTERS TO Where ducts pass through fire-rated interior partitions,install appropriately Jew.- EG EXHAUST GRILLE DONAT MACKAY 1. BE FURNISHED WITH ADJUSTABLE OPPOSED BLADE DAMPER.TITUS '350ZRL",ALUMINUM.NECK SIZES SHOWN ON DRAWINGS. rated damper,sleeve,and firestapping sealant. Fires to materials and DATE MATCH BORDER,STYLE TO.CEILING TYPE. installation methods are specife n other Sections. �- TG TRANSFER GRILL 1. SR WALL MOUNTED -SUPPLY REGISTERS Install duct mounted access doors at fire dampers,smoke dampers,combination T-STAY THERMOSTAT 11/05/01 DOUBLE DEFLECTION UNITS WITH HORIZONTAL ADJUSTABLE FRONT BLADES,VERTICAL ADJUSTABLE BACK fire/smoke dampers,motorized dampers,and elsewhere as required for access to Q BLADES.BLADES TO BE INDIVIDUALLY ADJUSTABLE.TITUS "30OFS", ALUMINUM.NECK SIZES AHOWN ON DRAWINGS. equipment,needing maintenance. Install occess doors downstream of equipment. TS TEMPERATURE SENSOR CD1 CEILING DIFFUSERS Provide sizes to allow for cleaning,inspecting,maintenance and adjusting of © SHEET TITLE equipment. HVAC RECTANGULAR HOUSING WITH LOUVERED FACE.FURNISH WITHOUT VOLUME DAMPER.WHITE ENAMEL FINISH. ® PS PRESSURE SWITCH METAL AIRE 5000 SERIES,TITUS TOG.NECK SIZES SHOWN ON DRAWINGS. Hangers and Supports: LEGEND, w. Suspend duct attachment from buildingattachment with one of the following GD2 CEILING DIFFUSERS hanger, types: ® SD SMOKE DETECTOR TITUS TMRA- TYPE 3,16"DIA STEEL CEILING DIFFUSER WITH DUCT MOUNTED VOLUME DAMPER,AG-100.NECK SIZES Galvanized sheet metal strip,o minimum for 0.034 by 1 inch wide. H H HUMIDISTAT SCHEDULE, SHOWN ON DRAWINGS. Galvanized steelrod,1/4-inch diameter,threaded for entire length. Q Galvanized steelwire,0.108-inch minimum. if Support equipment componentsl duct components and accessories independent of duct. ® IDS DESTRATIFIER SPECS separately. ® SHEET Install sheet metal sleeve to support dampers. Extend sleeve for motorized CF CEILING FAN 11 IN dampers to support operator. Diffusers,Registers and Grilles Installation:For units installed in lay-in (E) EXISITNG ceiling panels,locate in the center of the panel. Install units with airtight connection to ducts and to allow service and maintenance of dampers,air (R) RELOCATED extractors,fire dampers,etc. Cleaning: r installation of units,inspect , exposed finish. Clean exposed surfaces to remove burrs,dirt and smudges. (N) NEW Replace diffusers,registers and to grilles that have damaged finishes. FO FLAT OVAL DUCT - F/S D COMBINATION FIRE/SMOKE DAMPER J _ F/D FIRE DAMPER � O m tt 1z 13 . O FRELOCATE (E) j _ V Iy¢�,~Z UNIT HEATER V=U V • 0 SEE M301/1 z FOR LOCATION I I------------•-----00 ¢W zw i ,j i I II OpLm "Tee it== i REVISIONS 201 EXISITNG SUPPLY DIFFUSER TO REMAIN,SEE i/M301 FOR NEW WORK I I I I I I; ;I REQUIRED. REMOVE (E)UNIT ATER, T-SEAT,AND 202 DEMO EXISITNG SUPPLY DIFFUSER AND REMOVE DUCTWORK AS INDICATED. C FLUE THROUGH ROOF. II - i CAP DUCT AT MAIN. , CAP CURB ON ROOF I 203 EXISITING CEILING MOUNTED SUPPLY REGISTER TO REMAIN,SEE 1/M301 j I I I I I I I I FOR NEW WORK REQUIRED. I I I 1 i I I - REMOVE (E) ' 204 DEMO EXISTING SUPPLY DIFFUSER AND BRANCH DUCT,REPAIR DUCT FOR' I REMOVE (E _ _____ CEILING FAN ii Iy EXTENSION. SEE 1/M301 FOR CONTINUATION. j CEILING FAN I I_ 205 DEMO EXISTING DUCTWORK AS INDICATED. REMOVE (E) �T ® CEILING FAN ria-ss-ass:='ar_sar.�a-_evn-a II`a) r_'sssr SEE 3/M201 FOR ^ II .-_-_-_-_-_-.�I_-__-nccccrrcccer=I -_-ec_=-=_�-=_-_p_-_-_---_--_---i_-IILI'^ -- --_1---`--_•- `-I I-s-_f--�--- I '------_ -'-i-�-',-'----- -;iIII jI E RELOCATED,SEE 1/ II-- _-_-_-_-_- - -_- 206 EXSTING SUPPLY DIFFUSER TO B DEMOLITION I LOCATION. THISTAREA� _ _ _ - - --J ----- - ---•- _ --------- » � _=-- ' r-------- I 204 1. ALL FLEX DUCTS TO DROP STRAIGHT OUT OF BOTTOM OF MAIN DUCT.NO - - 90 DEGREE FLEX CONNECTIONS. K, _ ---------r IOS SHOWN ON PLANS ARE NET FREE AREA.INCREASE _________2. ALL DUCT DIMENS " - ----- . \ ----- -----_--------- DUCT SIZE WHEN DUCT LINER IS USED. --_- O D w-w� 3. ALL DUCTS SHALL BE SUPPORTED PER LATEST SMACNA RECOMMENDATIONS �' I o f AIEIANpON (E) I \ ` � _______________I,II ___ ______ --__----- _ _ ____-=_ _ _ U D WORK NQ--FOR SEISMIC SUPPORT. - - - SUPPL-F-DIFFUSERS-1 I;----- IVER CFM VALUES SHOWN AT ELEVATION WHERE4. ADJUST ALL FAN RPM TO DEL IN PLACE ' INSTALLED. I I I REMOVE 12 X72 E 5. EQUIPMENT AND WIRING SHALL COMPLY WITH LOCLA. AND STATE CODES. j I I 205 MVD - 1 I , I I EXISTING I , ` MOUNTED 6. GAS FIRED EQUIPMENT SHALL BE AGA APPROVED AND UL LISTED. I ' 1 1 a' ROOF 5 -------1 EXISTING j j i -- -; ROOF MOUNTED j OF 7. ALL EQUIPMENT SHALL BE ANCHORED TO BUILDING STRUCTURE. I I I I I ROOF MOUNTED: ' 9.CONTRACTOR SHALL FURNISH AND INSTALL DUCT SMOKE DETECTORS IN DUCT. I I I i SUPPLY DUCT OR MVD(E) REMOTE TEST,RESET AND LED TO BE MOUNTED AND WIRED UNDER DIVISION 16. I ; 34"DIAJE) 205 r 14"X72"( I 1 tE)SMOKE DETECT ` DETECTOR SUPERVISED BY FIRE ALARM CONTROL PANEL WHERE REQUIRED BY - I ,IN 71E) I I _ __ - I I I REMOVE 12"X72"ERm mLOCAL JURISDICTION. � L -------------'---'--------- -___--- --------------SMOKE DETECTOR _10.ALL EXPOSED DUCTWORK TO MATCH EXISTING ADJACENT PAINTED SURFACES. I I IN SUPPLY DUC, r r '--"------'--"-----PAINTING BY PLANTING CONTRACTOR. 1 16" IA.(E) `�� - WLae 11.BOTTOM OF ALL EXPOSED DUCTWORK AND RELATED DIFFUSER SHALL BE 201 34"DIA.tE) I I I IINSTALLED LEVEL WITH EXISTING EXPOSED DUCTWORK AND DUCT MOUNTED AB ON (E) REMOVE (E) 24"DIA.tE) j y NDIFFUSERS. DU WORK AND AC-7T-STAY I _ ____________________ _____ ________________SU LY DIFFUSERS I ____ ___________ _I _____------ m12.SIZES AND LOCATIONS SHOWN ARE FROM EXISTING CONSTRUCTION DOCUMENTS �� _ _ _ -----•----- ---•--- -•-'-'---'-. -""-'-----'----o-'--•- - ' w Q AND HAVE NOT BEEN VERIFIED. SIZES ARE SHOWN AS AN AID FOR THE IN ACE _ -_1 ' CONTRACTOR'S USE IN IDENTIFYING EXISTING SYSTEMS IN PLACE AND MUST ____ ________ "DIafEI 1 wj 201 I I REMOVE fE) U. _�---------- '--- j I I I 201 AC-2 T-STAY I O BE VERIFIED. I 16"DIatE) j I I 16" IA(E) rJ, 13.ON THE FLOOR PLANS,DARK DASHED LINES INDICATE ELEMENTS TO BE 1 205 18"DIA.(E) REMOVED,LIGHT SOLID LINES INDICATE EXISTING ELEMENTS TO REMAIN. I I I 14.PROVIDE INTERNAL DUCT LINING ON ALL RETURN DUCTWORK AND TRANSFER I I I d l � O �^ DUCTS. w 1 d I I I o f x 15.MOUNT TEMPERATURE SENSORS AND THERMOSTATS AT 48"A.F.F.UNLESS O NOTED OTHERWISE. I n I I I N I O 16.PROVIDE MANUAL VOLUME DAMPERS FOR ALL SUPPLY,RETURN AND EXHAUST j I I I MVD(E) V Z GRILLES AND DIFFUSERS. LOCATE DAMPER IN AN ACCESSIBLE LOCATION AS MVD(E) I '" I I I FAR AWAY FROM GRILLE/DIFFUSER AS POSSIBLE. I d _ j s I I•"( °° 1 17.SEE ARCHITECTURAL SHEETS FOR DETAIL OF CAPPING ROOF CURBS. j jN I I I ^a 18.HVAC CONTRACTOR SHALL REMOVE EXISTING DUCTWORK AND REINSTALL AS REQUIRED TO ACCOMMODATE WORK FROM OTHER TRADES. 201 I I I I I 2D1 1�11 19.HVAC CONTRACTOR TO REMOVE AND LEGALLY DISPOSE OF ALL MATERIAL, 16 IA I I I W I i6"DIA.(E) EQUIPMENT AND DEBRIS FROM SITE. OWNER RESERVES THE RIGHT TO RETAIN w I I I S I ANY OF THE ITEMS REMOVED. d - 1 16"DIA.(E) Zi I I ip I 1 201 N I I I 201 N I �y Y�+�1 201 I I I MVD(E) 1 16"DIA.(E) j 16"DIAAE) I - I U � I II I--•-•----- -- d - - - - - - - --------•- ------------- - F �- -------------------------------------E+-----------------------, o MVDiE) -- j j I I I j I I I 201 ; I I I 16"DIA.(E) W Lu z W I O I I o f Z , I 16" I j MVD(E) M O Lu 201 16"DIA.(E) 3 I I I 16"DIA.(E) f 1' n O O t I EXISTING j I I I IIY+++4411 r/1 Y 16"DIA(E). I 201 ROOF MOUNTED 201 I I MVD(E) (J V I J I 24"DIA.(E) I U j i 16"DIAAE) I j I I I 205 I _ I 16"DIA.(E) ~ W I I 201 I I I EXISITING I I I I -f I- I � i ROOF MOUNTED' I 76"DIA.cE) I REMOVE (E)PIPE i I i ' REMOVE (E)EXHAUST I IHOOD AND CAP I ---_-_-_-_-_ FAN AND CAP CURB ON ROOF i i 205 v' I ' I ---------------------------------- i I--I i==------- I I--------- CURB ON ROOF i --9--* ' i I (E)SMOKE DET CTOR --Ia- ------------------ I --�•---------•-----------------I ' 1Y� I I I 202IN SUPPLY DUCT j - - I r � ------ E>SMOKE DETECTOR a I IN SUPPLY DUCT REMOVE (E)GENERATOR �"' I I ' ' EXHAUST THIMBLE AND �_� yj i' �; ; 205 I i}(----------- _ RELATED PIPING,CAP > Il - ,•, \`I ______ I I N _-__ 1 CURB ON ROOF °- --�-=�-'---•----11-Jh---1J1 a� ' ---___-__-� 1 ROOF = ---- ROOF ri 12"X18"(E) ' --- _ _ -O I UP THRU i i 6 __I t j�.r I Zi o c00 MOUNTED 204 1 204 I, m I I 16"DIA.(E) I 16"DIA.(E) 1 16"DIA.(E) 14"DIA<E 201 1 201 1 201 " -- 205 I I I REMOVE (E)PIPE REMOVE (E)INTAKE j ) I I 201 HOOD AND CAP I HOOD AND CAP - DON (E) ISd j j j j ' REMOVE (E)RG CURB ON ROOF CURB ON ROOF re E IPMENT, ' 8"Dla(E) _ o Isl T..WORK PAID I I i i � • --------•'�� I M D , `r S PLY DIFFUSERS I ' LACE I 1 ' IA( M D(E) 2611 DIXIE) 32"DIA(E). ® I 1 la( ) PLATFORM DEMOLITION PLAN ®I I 12"Dla<E) 3 -" j I MVDtE) MVDfE) I 22"DIA.(E) M201 SCALES/a" - 1'_0" I 201 � a 1 I d d� 8"DIA.(E) 201 I I W 10"2 IatE> 16"DIA.(E) 8 o I < I 1 1 ` r 24"X24"TC(E) I I L i 16" (E) ;o 201 REMOVE (E) g^p1A<E) 4qs ey 24"X48"TG(E> I I I I AC-6 ACCUSTAT, 203 16"Dla<E)FROMSEE 1 I 201 "� y I I ABOVE,RD2/M201 NEW iLOCAT LOCATION 1 I a _ FOR CONTINUATION ----_t --_- _- - -_- -------- 9783 6"DIA. 24"X18"RG(E) I I I r�r f oa 72"%24"fE) - .I I g"DIA.(E) -I R •S I `_TT .• f `` 201 201 p r ` C T M __ `.L M w 16"p R�[�2/M201 FOR r —► I I T,I ROOF MOUNTED O T P r ,. (E) __ ? I 14"X14"(E) 16"DIA(E) 16"DIA.(E) WNTINUATION 201 6"Dla(EY I I I'# d RED 2/M201 r-�18"DIA.(E) „-„ RELOCATE 24"X 8"TG(E) - __ - -_-- - ----- -'-' •-----0 ¢ iv MVD FOR CONTINUATIONT` T 18 X8 ERfE) 8"__E) ;I ' ur UP THRU ROOF AS INDICATED OIV M301/1 -•-- •-------------?• -----------•--- --•----- --a• - -L--1r .� 0 0 - -1 - - 16 �FG2�F0s4(s'3CYikffdr:ra s:as:sa RELOCATE 24"Xy4"TG<E> II 14" t —► 16" IA.(E) •— 4J THRO --� -------- 6 X6 ERfE) DWCT P U MEZZANINE. CTA JOB NO. AS INDICATED ON I M301/1 ,I rr-I _-_ 1 r_►- - ---- - ------R. ---- -----'-----' O ---- --_- - - - - - --RH:2/M201F R CONTINUATION _ _ _ •-------------•-- - -----�„�IA.LE)-y '-- -I-------•-- - - T-- r-------- i I DELLCC -_-_#------ I- -- I REM6VE<E) RE7-VE (E> 14" ER(E) E)EF-6 28"DIA(E) 22"OIAfE) --- - II I n'V-STA '- —� I T-STAY VD II. 6"DTA 11 AC-3 T-STAY I -p T-STAY .•�I L, I i l I II 1 L. 10"DIME) "X8"(E) -.10"X8"fEI 4 I T ®' ' ' 1�~ 1; 11 I I / 16"DIA.(E) 1 -l II II 1 __ 10 DIafEI- -- - - - -- - - D( DIAf - - - IMV�(E)& VD(E) MACKAYi MVD(E) _O LL O I tE 6 I y I ,1 �� a ii-i----- --------- A.-----'t_I ' � I 201 <E) ----- „ - - - - - - - - -V EI � 8" E) ATDATEDON I I > 14"X14"fE) 6"X6"EG E "Dla(E) ROOF 'J 1 I g,----•--- Iv0sr01 RE'1/M201 FOR 6"X6"EG (E) RE:1/M201 FOR DUCT DOWN I MOUNTED I - c = I I'� I - ----- - - - �l 5 CONTINUATION CONTINUATION TO BELOW I - SHEET TITLE 201 201 201 I " `� + 201 204 201 206 206 206 12"DIA 201 P 16"X16"(E) 18"Dla(E •`• REr1/M201 FOR 201 j I I 206 202 I 1�� CONTINUATION (E 4203 203 8" .(E10"DIAAE) 10"DIA.(E) 10"DIAJE) 10"DIA.CE) 10" A.(E)I (E) 8" a(E) _..12"X12"(E)ROOF MOUNTED N I"IVAC DEMO s ------------------------------_--- — PLAN D — — � I 24"X76"(E) ------------------ (E ------------------------- I i 5 I SHEET 30"X24"<E> "X6"(E) '" 8"(E) 12"X12"(E) MOUNTED I � I t .... 201 I I I I io 8"X8'(E) 201 `LT I I I I t ILL 14"XB"RG(E) E I l � REMOVE (E) n rl2ol 24"X20"RG(E) cm SMOKE DETECTOR 11 tE) AC-5 T-STAT,SEE 201 201 ' IN SUPPLY DUCT ROOF MOUNTED LOCATIONR NEW x MEZZANINE DEMOLITION PLAN HVAC DEMOLITION PLAN p - M20i SCALE'/e" 1'-0" NCRTN • M201 SCALE:'/g"- T-O" . �t I I I I (REFRIGERANT LINES i I i i I (SEE ARCH(ECU RAL I N SHEETS FOR ROOF 2 N) (CURB DETAIL ROOF = Q FW-W F I , I I MOUNTED C.7 Z u� I I I I I - 2 R) I. ROOF I 10 2„X12"EG(N) I O V V •308 = MOUNTED (N 750 CFM 1------------------ Q W' y 1 DRyy I I I I I I 303 ! 14"HOYNGAS E INE(N) , CD' 1 W OPLAN kOiEs I I I I I I 304 3000 CFM ___ _____ I 36"X20"RG(N) �'m= ' 36"X20"RG(N) �� � '� y 3000 CFM r" 1 f"" )` 750 CFMSMOKE DETECTOR I I I I I T AC-10 TEMPERATURE/ ' I C'""" -" I _- y` IN SUPPLY DUCT 301 EXISTING SUPPLY DIFFUSER CLEAN AND REBALANCE TO CFM SHOWN. REVISIONS I I I I I I 24"%12'YM L___,_____J I 12"X72"(N) -- _ 302 EXISTING CEILING MOUNTED SUPPLY REGISTER CLEAN AND REBALANCE - -` /-=► P THRU 20"X20" ' CD-1 TO CFM SHOWN. I I I I I I HUMIDITY SENSOR (N) -- H- 20"X20"(N) L ' n OOF 20 14"DIA.(N) 24"X12"TG -� ' 750 CFM 303 MOUNT WITH TOP OF UNIT 6"BELOW ROOF STRUCTURE. - I I I =a =___ 750 CFM MVD(N) 304 GAS VENT UP THRU ROOF,RE:4/M101. ,I 24"X12"TG<N). I (N t1 ' �� /SI i 14"DIACN) I R00 MO TED T 8 I I I I ..•.� 750 CFM 225 CFM SA ISMOKE(N)E ECTOR W� 3 305 1"ACOUSTICAL DUCT LINING. d 24"DIACN) 3b6 6"DI AT UNIT - O9 M ONTED ' �VD(N) IN SUPPLY DI�CT 600 FCFM UOSA. S MVDCN) 306 24"X48"TRANSFER GRILLE,2500 CFM.DUCTWORK SHALL RUN BELOW V 6"DIA.fN) I - 24"X48"TRANSFER RGRILLE,2 I I t 100 CFM - 12"DIA.(N) AT UNIT,•+ _ IN - -� 14 UNIT o 1 D-1 -\ `_ CAT ^, MUD( ) 22gg ppI �- �14" IA(N1 14"OIA(N) 307 RELOCATE EXISTING SUPPLY'DIFFUSER AND EXTEND EXISTING DUCT ' - - __-,- 12"A5P CFM,I I16"D CD-1 AfNI� MVDCN) 0 CF 960 C"RGtN) CD-1 12"DIACN) 11200 CFM = 12 OIA.fN 14"DIA.(N) TO NEW LOCATION. CLEAN AND REBALANCE TO CFM SHOWN. - ® 14"X72"(N) 960 CFM.r I �1500 CFM 1 36"X14' - -��j - -11200 CFM -1200 CFM 308 RE:5/M101 FOR COMPUTER ROOM AIR-CONDITIONING UNIT FLOORSTAND MVDI(N) fN) "6A. VO(N) v I p 14"DIA.(N) DETAIL. ROOF MOUNTE y �� '18"B)A N>• �' i v a T --' .(N) 28"DIACN r <N) J 16"DIAfN)�' --- �" ---_ _ 750 CFM - - - - -------------- ___ _ 1 240 CFM OSA -' '�--------' --- - --'- --. - - ,�----- - - - -�. MV6(NI--�^ - ----- -- - - - ---� - J. 309 RE:6/M101 FOR ROOF CURB DETAIL. 1 E) AT U IT 2b"DIA.(N) - CD-1 - O DUCT DOW THRU I 18"DIA.(N) -- - II7 u`' } I I la 10"DAfN) PLATFORM LOOR, 1,500 CFM D ECTOR : , 10"DIA I 12"DIA.(N)r.1, I W T-STAT ^ IN SUPPLY : - I I .,,,li AC-8 MOUNT �� VD(N) A ) SAW CUT AS I ? (N) y I MVDC ) MVD(M I �- -► REQUIRED I d DUCT I �_ ,i,�_ tN) •16"DkF.EN 48'A.F.F. VDfN) CD-1 (N) 12 CD-1 a r� 6"%6"ER<M 500 CFM ) ❑® 14"DIA.(N) c ROOF MOU TED -� ' I 12"DIACN)!'` 500 CFM 12'X12"ER(N CD-1 I CD-1 I a '=- - r' iu l D-1 CD-1 Iy 10"DIA.(N) 1. ALL FLEX DUCTS TO DROP STRAIGHT OUT OF BOTTOM OF MAIN DUCT.NO 10"DIA(N) 10"DIACN) 1,000 CF I 690 CFM ('SA i , y, I i 550 CFM , �1B"DIACN) 16"DIA(N7 300 CF'F�• 90 DEGREE FLEX CONNECTIONS. 400 CFM 1400 CFM MVO(N AT UNIT ( �' .1200 CFM 1200 CFM MVDCN 2. ALL DUCT DIMENSIONS SHOWN ON PLANS ARE NET FREE AREA INCREASE S 14"DIAW) I(N)T-STAT T +- �� � �. Nj ICD-1 875 CFM i4 IN)T-STAT DUCT SIZE WHEN DUCT LINER IS USED. \,,. 'AC�13 MOUNT I_ CD-1 _ __- _ __,.. I 6"DIA.fN) _-•-�-_ --,gC_1 MOUNT -_- _-_-_- 10"DIACN) � �6 a� -------_- ..,_ ---'#AC_A.F.F- - -----' -(p----14"DIACN) O�CFFA--'-'-'----- 48"A.F.F. _ _ 3. ALL DUCTS SHALL BE SUPPORTED PER LATEST SMACNA RECOMMENDATIONS, �/ I (N T- A I I 1,000 CFM I T T I�• CD-1 -CONNECT TO FOR SEISMIC SUPPORT. T 36"X14"tN) •"� 10,DIA.(N) AC 12 0 NT;' 26"X24"(N) I I i .400 CFME- --► EXISITING 48"A .F. ' SM KE DETECTOR 24"X4 "RG(N) IN)T-STAT 4.ADJUST ALL FAN RPM TO DELIVER CFM VALUES SHOWN AT ELEVATION WHERE � 305 N SUPPLY DUCT "309 5150 CFM - I 305 AC-11 MOUNT I I INSTALLED. ...' SMOKE DETECTOR' - . ` (N) 14 36"X40"FOtN) 48"AF.F. Q I ----"- IN SUPPLY"DUCT I I I ROOF MOUNTED - --------- ; 2 (E 5 5.EQUIPMENT AND WIRING SHALL COMPLY WITH LOCAL AND STATE CODES. � - - --- fE 12"X12"ER fN> 6. GAS FIRED EQUIPMENT SHALL BE AGA APPROVED AND UL LISTED. 1 2400 CFM OSA, I I ROOF MOUNTED I REPLACES (E), ROOF fEI AT UNIT I •- •-• 48"X34"FOfN> _, 1,500 CFM OSA 500 CFM MOUNTED ROOF MOUNTED i---- ' CAP fE ' I , i I i AT UNIT I 7. ALL EQUIPMENT SHALL BE ANCHORED TO BUILDING STRUCTURE. y 1575 CFMAT UNIT MfSAVDCN i DUCT ' I -- -------- r ' ------ -------- r 309 , -i 12"X12"ER (N) 9.CONTRACTOR SHALL FURNISH AND INSTALL DUCT SMOKE DETECTORS IN DUCT. CD, ' REMOTE TEST,RESET AND LED TO BE MOUNTED AND WIRED UNDER DIVISION 16. ) I z _ _- I I I REPLACES (E), 20.-Di +f i d 96"X20..(, 305 96"X20"(NI I MVDCN) ' I 500 CFM N r" DETECTOR SUPERVISED BY FIRE ALARM CONTROL PANEL WHERE REQUIRED BY i S ""---"" _ _ CD-2 I I O M LOCAL JURISDICTION. 1,750 CFM 20"DIA�1 ' MVD(N) I 2500 CFM 3 ' - I M 00 M 10.ALL EXPOSED DUCTWORK TO MATCH EXISTING ADJACENT PAINTED SURFACES. CONNECT - CD 15 ' PAINTING BY PAINTING CONTRACTOR. , - i� 2,500 (N) R DUCCO2T SENSOR D i i I m TO EXISITING 2,500 CFM ROOF MOUNTED o _ _-- ij'-1 0 M -' CO2 SENSOR & Z 13,600 CFM RA DUCT MOUNTED n 11.BOTTOM OF ALL EXPOSED DUCTWORK AND RELATED DIFFUSER SHALL BE CONNECT DUCT MOUNTED d 2400 CFM OSA ASPIRATOR BOX(N) x I I INSTALLED LEVEL WITH EXISTING EXPOSED DUCTWORK AND DUCT MOUNTED NEW AC-1 T-STAT TO EXISITING AT UNIT TOP OF DUCT CAPT(E) i C REPLACES(E7, ASPIRATOR BOX(N) S OPE I a - DIFFUSERS. 74•F SETPoinT 13,600 CFM RA, I MVO(N %TEMPERATURE TOP OF DUCT OPEN _ __ 1 _----------.------------- .---------------- /� 12.SIZES AND LOCATIONS SHOWN ARE FROM EXISTING CONSTRUCTION DOCUMENTS -•-- T - -- - '-' ----'-'-'-'---- - ------ ------- - --"-------- -----o----------- --- ----- - --- - - " '4 - -""-* -(�1 co AND HAVE NOT BEEN VERIFIED. SIZES ARE SHOWN AS AN AID FOR THE -- ="- ' 301 18"DIA.tN ( I y.J ,NEW AC-2 T-STAT `/ "' CONTRACTOR'S USE IN IDENTIFYING EXISTING SYSTEMS IN PLACE AND MUST - CAP (E) BE VERIFIED. DUCT 1 1,500 CFM D-2 r 18"DIA.(N) CD-2 � 301 74''REPLACES (E), v I 13.ON THE FLOOR PLANS,DARK DASHED LINES INDICATE ELEMENTS.TO BE SETPOINT 11.500 CFM 24"DIA.(N) TEMPERATURE RATURE 2500 CFM I 1,050 CFM TEMPERATURE REMOVED,LIGHT SOLID LINES INDICATE EXISTING ELEMENTS TO REMAIN. 301 I 1 I ty�yj 1 14 DUCTS.E INTERNAL DUCT LINING ON ALL RETURN DUCTWORK AND TRANSFER 7000 CFM i I Z I P✓ O (z I d I I I w (�Jj 15-MOUNT TEMPERATURE SENSORS AND THERMOSTATS AT 48"A.F.F.UNLESS I o I S I I O NOTED OTHERWISE. "1 CD-2 ? N 124"DIA.<N) M I I Q 4 OOC 16.PROVIDE MANUAL VOLUME DAMPERS FOR ALL SUPPLY,RETURN AND EXHAUST 2,500 CFM ^ (�W GRILLES AND DIFFUSERS. LOCATE DAMPER IN AN ACCESSIBLE LOCATION AS I I MVDCN) I i f 1 Z FAR AWAY FROM GRILLE/DIFFUSER AS POSSIBLE. 301 i i C) Ln O 17.SEE ARCHITECTURAL SHEETS FOR DETAIL OF CAPPING ROOF CURBS. 1.000 CFM I I I ^CL 18.HVAC CONTRACTOR SHALL REMOVE EXISTING DUCTWORK AND REINSTALL AS D-2 10"DCO-I r/1 REQUIRED TO ACCOMMODATE WORK FROM OTHER TRADES. I 2,500 CN) 250 CFM i 2,500 CFM 250 CFM i 12"DIA.(N) I I 301 19.HVAC CONTRACTOR TO REMOVE AND LEGALLY DISPOSE OF ALL MATERIAL, EQUIPMENT AND DEBRIS FROM SITE. OWNER RESERVES THE RIGHT TO RETAIN j 24"X12' i 1,000 CFM TG(N) } MVDCN IAC•15 T-STATT I II ANY OF THE ITEMS REMOVED. i/ T 72'F TEMPERATURE 1q NO WORK UNDER THIS CONTRACT (TEMPERATURE I ,„ ON THIS SIDE OF DEMISING WALL, I 24"XI n I I C 24"X12° MVD(N) EXISTING SYSTEMS TO REMAIN �T i 301 z MVD(N) 0.0 '' 301 10"DIA.(N) 301 i 1,500 CFM o VD(N) 10"DIAy(N) `250 6F i 7,050 CFM i 1.000 CFM I N 8"DIA�(N) 12"X6"UP .. -1,G----- --'--- -- - - -r --- THRU ROOF --'-'-----'----- - -----------'-'---- \ �N --- ------------------------- --------- - -------------- - -� - - - ----- 8DD)A.(N) 12" CFM(N) , ram' I I 12"X72"RG(N) r T 200 CF 750 CFM ,�•••-•� 12"DIA.(N) ,ROOF 500 CFM z MOUNTED I 301 CD-1 1,000 CFM 1801 CFM) 1 12"X12"(N) AC-14 T-STAT(N). MVD(N) W 72'F SETPOINT a I F/D(N) o MVD<N) I 8"DIA(N) t" TEMPERATURE r Lu TGfN)2„ y (NIRo 7 8"DICD- O Z 8"DIA(N) I CD-2 ROOF MOUNTED � I ,I CD-2 24"OIA.(N) 150 CFM OSA �- 180 CFM i �• 24"DIA.(N) I 2,500 CFM I AT UNIT , -- '• 307 2,400 CFM 10"DIA.CN) 1,000 CFM F/D(N)STYLE "G' MVD(NI I i MVDCN> OKE DETECTOR PROVIDE MOUNTING I I I IN SUPPLY DUCT(N) ANGLES 14"X72"( 12"DIA.tN) O W - 1 I CD•1 I I I I 8"DIA(N) 301 I 307 MVD(N) I (E 4 1 T 180 CFM 850 CFM 1,500 CFM 10"DIACN) 675 CFM 301 IN)T-STAT I y:-- 24"DIA.(N) I CD-1 (E 3 •• OSA AT UNIT 301 AC-7 MOUNT _ z 1 1,000 CFM 5'-0"A.F.F. � 8"DIA.<N) ROOF MOUNTED __ ___ __ __ 675 CFM OSA c CD-2 1,250 CFM 180'CFM /'� �y I„I„I CAP (E) , AT UNIT a 2.500 <F DUCT ct 2,500 CFM MVDCN) z i I IF MVDCN)) -' I a i , I CD-1 W CONNECT I ' o -'- ---------TO EXISITING ��' - i 1 --- - - '--I-- I '------- AI -- --- --iso M--------- O i---- C8'"DIA.(N) 1 MVD(M CD-2 I I (E) 7�1 /T 1 '^ 1,750 CFM 1 1,500 CFM rN ! F-� J� 16"DIA.(N) ) i I I I SMOKE DETECTO 240 CFM OSA IN SUPPLY DUCT(N) ---- AT UNIT CONNECT CD-2 ICD-2 I I , i r� I TO EXISITING 24"DIA.(N) 24"DIA.(N) DUCT OPEN MVDCN z 2,400 CFM 12,500 CFM I I i ON TOP (N). 1,425 CFM 1,42 CFM 1,425 CFM do 1 I 301 I 301 1 Sot 301 "X70"(N) sy I I 1 250 CFM ` "%10"TG<N) , 2 ni rr I 1 I • CD-2 UCT OPEN -'n ® I 'T ON TOP (N). 18"DIA(N) I I NEW AC-6 T-STAT 1,750 CFM REPLACES (E) 12"X12"(N) 1 I I 12"X12"TG(N) 1350 CFM 7,425 CFM 1,425 CFM I I I 301 2a^x24^TccE) RELOCATED tEA) NEW AC-3 24"X24"TG(E) 301 301 500 CFM 100 CFM (ANAL 24"X48"TG(E) 302 T-STAT S F RELOCATED } 1350 CFM 301 I 301 301 260 CFM 4"X48"TG I (EA) 302 I I I I i. . 1,425 CFM 301 ¢� --�------- ----------------------'-'�- ---- - ------------,- --� - --220 CFM -- ----- _-=_-_---_- --- - I 9783 % - T RE:2'M301 FOR aSA,tlVn 72"X24"(EI I RG 1,300 CFM NEW AC-4 T-STAT CONTJ�NUATION REP2%M301 FOq REPLACES (E), CONTINUATION 200 CFM S E ov F I 74'F SETPOINT TEMP. I ,' 301 y COTT MPG. 72"X24"fN)�,I?, I RE:2/M301 301 9 CD-1 T CONNECT TO i 301 70 CFM - ROOF MOUNTED 8"DIAw) „ BUD ., � I � FOR CONTINUATION EXISITING T 40 F � ,ER 350 CFM � _ _ _ _ 1 100 CFM 8„DIACN -' -'- - - - - - - -- - - - ------- - ----J. - - -DUCT UP T}IR----------------- -'--- --- ---- -'-- --- ER 90 CFM --------0 CTG JOB NO. Him MEZZANINE. T i MVDCN) CONNECT TO 0 ECT _ MVDW) RE:2/M30.1 _ _-_-_---_-. f- : - ---+�------ - -- ----- EXISITING ----'-'- - -VXISRING-- -- ---- ------- ----- ---------- ---•-'------ ---'-' ---------- ---- - - - -- ----- -'- ------ - DELLCC 10"DIA.(N> AT ® ER 400 CFM CD-1 MVOfNI `^ MVDCN 6"DIA.(N fNIAC-5 T-STAT 307 100 CFM 301 T REPLACES (E) I 1 DRAWN CHECKED I ,00 CFM ® � � 250 CFM 1 350 CFM i 8"DIA.(N) 301 _ --- - - - - --- - - --- -- ----- 20 CFM W 6"X6"EG (E) RE:1/M301 FOR " RE:1/M301 FOR I .-- I i 260 CFM CONTINUATION 90 CFM 50 FM 20 CFM CONTINUATION ' "III 1 I '` 6 DIACN) ---- -� - -•- - - - - - - I 1 -- - I i I : :i If00 CF .- y y - - - - - - - - 0 L DATE --, 6"X6"EG (E) - -----•------ 301 90 CFM 301 301 RE:1/M301FOR 280 CFM � SHEETLE v iI CONTINUATION - - I _ 301 I CD-1 I •....... I 307 I CD-1 CD-1 CONNECT TO 307 307 TITLE T ' 8"DIA.(N) 10"DIA.(N) 8"DIA.(N) EXISITING - 1150 CFM I 302 302 I 100 FM I 250 CFM 300 CFM 35 CFM 350 CFM I ROOF MOUNTED �- N HVAC REMODEL ----t----'-'-'-------�-----750C _�A.L 7Y5Q _-(EA.�----�'-'-------'----- -------'-'--------------------------'-----------'-------'-'-'-------'-'-------------'-'-'---- -----'-'---- (E) ROOF MOUNTED i I I I I O PLAN 560 CFM OSA a D I I I AT UNIT 301 �11F)M CFM .14"X6"RG(E), - 250 CFM 24"X20"RG(E) tE) 11 301 301 (7\ V (/�, o (ta o . /n\ 1 13�9 1 1,450 CFM ROOF MOUNTED 250 CFM 250 CFM ��J 2 MEZZANINE REMODEL PLAN HVAC REMODEL PLAN $ M301 SCALE:I/e -1'-0" . M307 SCALE:I/8"-T-O" . AE NORTH . . ... .__ DIVISION 16 - ELECTRICAL SCOPE 16140 - WIRING..DEVICES 16999 • GENERATOR- . THIS WORK CONSISTS OF,,BUT IS NOT NECESSARILY LI M]TED T0, THE FURNISHING OF ALL LABOR, EQUIPMENT SUMMARY A. ACCEPTABLE MANUFACTURERS: PASS & SEYMORE, BRYANT GE, HUBBELL, LEVITON. APPLIANCES AND MATERIALS AND THE PERFORMANCE OF ALL OPERATIONS IN CONNECTION WITH THE �I. LIGHT SWITCHES SHALL B, B. DEVICES: 1.1E 20 AMP, 120/277 VOLT AC RATED AND INDUSTRIAL GRADE. INSTALLATION OF ALL ELECTRICAL WORK COMPLETED, IN STRICT ACCORDANCE WITH SPECIFICATIONS AND/OR. 2. GENERAL RECEPTACLES SHALL BE SELF GROUNDING 5-20R AND INDUSTRIAL GRADE. GFCI A. THE OWNER.WILL PROVIDE A 335KW GENERATOR WITH A 200 GALLON SUB-BASE FUEL TANK. THE .. -O In g O AWI NOS, APPLICABLE CODES, INCLUDING INCIDENTAL MATERIALS NECESSARY AND REOUI RED FOR THEIR RECEPTACLES SHALL BE 20 AMP FEED THROUGH TYPE WITH TWO UTILIZATION POINTS. 00 NOT GENERATOR WILL COME FIXED TO A TRAILER. EC H RESPONSIBLE FOR REMOVING GENERATOR FROM 1yn,� COMPLETION. CONNECT DOWNSTREAM DEVICES TO LOAD SIDE OF GFI. ISOLATED GROUND RECEPTACLES TRAILER AND SETTING IT ON A CONCRETE PAD. EC IS RESPONSIBLE FOR INSTALLING AND CONNECTING ''N v W �Q y PROVIDE' - FURNISHED ANDINSTALLED COMPLETE. 'OR APPROVED EQUAL' - OR EQUAL AS SHALL BE 20 AMP AND EQUAL TO PASS&SEYMORE 106300 SERIES. ALL OWNER PROVIDED GENERATOR EOUI PMENT AND ACCESSORIES. THE EXISTING GENERATOR IS A -. W.Lw F-`v_I APPROVED BY ENGINEER, •CM-.• CONSTRUCTION MANAGER, •CONTRACTOR• DIVISION 16 3. COLOR SHALL BE GRAY. CATERPILLAR 3406 SERIES, COMPLETE WITH: WEATHER RATED ENCLOSURE, FUEL SYSTEM, CRITICAL = Q�,..LL3CONTRACTOR, -EC- ELECTRICAL CONTRACTOR (I.E. DIVISION 16 CONTRACTOR)" C. DEVICE PLATES: MUFFLER, UNIT MOUNTED CIRCUIT BREAKER, REMOTE ANNUNCIATOR, JACKET WATER HEATER, BATTERIES V Z '�'A 16010- GENERAL ELECTRICAL 1. DEVICE PLATES SHALL HAVE OPENING FOR DEVICE INTENDED AND SHALL BE NYLON. COLOR AND CHARGER. AND CONTROL PANEL. LEGEND 9 _u A. INTENT OF DRAWINGS: DRAWINGS ARE PARTLY DIAGRAMMATIC AND DO NOT SHOW EXACT LOCATION SHALL MATCH DEVICE. - - 7-Z'..w V it 0 OF CONDUIT OR EQUIPMENT UNLESS SPECIFICALLY DIMENSIONED. 2. WEATHERPROOF RECEPTACLE COVERS SHALL BE TAYMAC •20510 FOR AREAS OF 1.2 SUBMITTALS B. WORKMANSHIP: CONTINUOUS-USE AND LEVITON •4992 OR EQUIVALENT FOR AREAS OF NON-CONTINUOUS USE. SYMBOL LIGHTING O Q Iy. v,Z J 1. WORK SHALL BE ACCOMPLISHED BY WORKMEN SKILLED IN PARTICULAR TRADE, IN 16415 •-AUTOMATIC TRANSFER SWITCH A. PRODUCT DATA: SUBMIIT MANUFACTURER'S DATA,ON ACCESSORIES TO BE PROW QED BY THIS O j w CONFORMANCE WITH BEST PRACTICES AND ACCEPTED STANDARDS. A. MANUFACTURER: ASCO., CATERPILLAR;-KOHLER, OR ONAN CONTRACTOR. m F.- 2. WORK SHALL CONTRIBUTE TO EFFICIENCY OF OPERATION, ACCESSIBILITY, MAINTENANCE AND B. THE TRANSFER SWITCH SHALL BE EQUAL TO ASCO MODEL 940 WITH GROUP SEVEN CONTROL PANEL. APPEARANCE. NO PART OF INSTALLATION SHALL INTERFERE WITH OPERATION OF ANY OTHER C. TRANSFER SWITCH SHALL' HAVE THE FOLLOWING FEATURES: 1.3 ENGINE-GENERATOR SET ACCESSORIES �__� LAY-IN OR RECESSED FLUORESCENJ FIXTURE SYSTEM OR PART OF BUILDING. 1. UNDERVOLTAGE SENSING FOR EACH PHASE OF NORMAL SOURCE: SENSES LOW PHASE-TO- - . 3. NON-SATISFACTORY WORK SHALL BE CORRECTED AT NO ADDITIONAL EXPENSE TO OWNER. GROUND VOLTAGE ON EACH PHASE. PICKUP VOLTAGE IS ADJUSTABLE FROM 85 TO 100 PERCENT A. PROVIDE TRANSFER SWITCH AS SPECI FI EO IN 16415. C. I. THE SELECTRI OF NOMINAL, AND DROPOUT VOLTAGE IS ADJUSTABLE FROM 75 TO 98 PERCENT OF PICKUP VALUE. � LAY-IN OR RECESSED W/ BATTERY BACK-UP EMERGENCY POWER FLUORESCENT FIXTURE p�VI to-N S 1. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF SATISFACTORY AND FACTORY SET FOR PICKUP AT 90 PERCENT AND DROPOUT AT 85 PERCENT. B. PROVIDE NEW TANK HEATERS. INSTALL TANK ACCESSORIES PER APPLICABLE CODES, STANDARDS, AND COMPLETE WORK IN ACCORDANCE WITH THE INTENT OF DRAWINGS AND SPECIFICATIONS. 2. TIME DELAY FOR OVERRIDE OF NORMAL-SOURCE VOLTAGE SENSING'DELAYS TRANSFER AND MANUFACTURERS REOUIREMIENTS. �O SURFACE MOUNT FLUORESCENT FIXTURE PROVIDE, AT NO..EXTRA COST, INCIDENTAL ITEMiS REGUI RED FOR COMPLETION OF WORK EVEN ENGINE START SIGNALS. ADJUSTABLE FROM ZERO TO SIX SECONDS, AND FACTORY SET FOR ONE THOUGH NOT SPECIFICALLY MENTIONED OR INDICATED IN SPECIFICATIONS OR ON DRAWINGS. SECOND. C. PROVIDE BATTERY WARMERS. � WALL MOUNT 2. IF, AT ANY TIME, AND IN ANY CASE, CHANGE IN LOCATION OF.CONDUIT, OUTLETS, FIXTURES, 3. VOLTAGE/FREOUENCY LOCKOUT RELAY: PREVENTS PREMATURE TRANSFER TO GENERATOR SET. OU FLUORESCENT FIXTURE SWI TCHES,.PANELS, ELECTRICAL EOUI PMENT OR ASSOCIATED COMPONENTS, ETC., BECOMES PICKUP VOLTAGE 1S ADJUSTABLE FROM 85 TO 100 PERCENT OF NOMINAL. FACTORY SET FOR D. PROVIDE BLOCK HEATER OF PROPER WATTAGE AND VOLTAGE, THERMOSTATICALLY CONTROLLED TO NECESSARY DUE TO OBSTACLES OR INSTALLATION OF OTHER TRADES, SUCH REQUIRED CHANGES PICKUP AT 90 PERCENT. PICKUP FREQUENCY IS ADJUSTABLE FROM 90 TO 100 PERCENT OF MAINTAIN ENGINE COOLANT AT 90 DEGREES FAHRENHEIT (32 DEGREES CELSIUS). THE BLOCK SHALL BE MADE DIS BY CONTRACTOR AT NO EXTRA COST. NOMINAL. FACTORY SET FOR PICKUP AT 95 PERCENT. HEATER SHALL BE INSTALLED WITH SHUT-OFF VALVES FOR MAINTENANCE. VALVES TO BE FIELD INSTALLED. ® SURFACE MOUNT FLUORESCENT FIXTURE 3. CONFLICTS DISCOVERED DURING CONSTRUCTION SHALL BE IMMEDIATELY CALLED TO THE 4. TIME DELAY FOR RETRANSFER'TO NORMAL SOURCE: ADJUSTABLE FROM 0 TO 30 MINUTES: ATTENTION OF THE CM FOR DECISION. DO NOT PROCEED WITH INSTALLATION IN AREA OF FACTORY SET FOR 10 MINUTES. PROVIDES AUTOMATIC DEFEAT OF DELAY ON LOSS OF VOLTAGE OR E. INSTALL OWNER PROVIDED REMOTE ANNUNCIATOR AT FRONT OF BUILDING NEAR FIRE ALARM ANNUNICIATOR. PENDANT OR SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE QUESTION UNTIL CONFLICT HAS BEEN FULLY RESOLVED. SUSTAINED UNDERVOLTAGE OF EMERGENCY SOURCE, PROM OED NORMAL SUPPLY HAS BEEN 4. COORDINATE ALL ELECTRICAL WORK WITH OTHER TRADES TO PREVENT UNNECESSARY DELAYS IN RESTORED. � I PENDANT OR SURFACE MOUNTED EMERGENCY FLUORESCENT LIGHT FIXTURE THE CONSTRUCTION ON SCHEDULE. 5. TEST SWITCH: SIMULATES NORMAL-SOURCE FAILURE. 1.6 EXAMINATION 5. EXCAVATION AND BACKFILL REQUIRED BY ELECTRICAL INSTALLATIONS SHALL BE ACCOMPLISHED 6. SWITCH-POSITION PILOT LIGHTS: INDICATE SOURCE TO WHICH LOAD IS CONNECTED. BY THIS CONTRACTOR. 7. SOURCE-AVAILABLE INDICATING LIGHTS: SUPERVISE SOURCES VIA TRANSFER-SWITCH, NORMAL- - A. EXAMINE AREAS AND CONDITIONS UNDER WHICH DIESEL ENGINE-DRIVEN GENERATOR UNITS ARE TO D. GUARANTEE-WARRANTY: THIS CONTRACTOR SHALL AND HEREBY DOES WARRANT AND GUARANTEE: AND EMERGENCY-SOURCE SENSING CIRCUITS. BE INSTALLED AND NOTIFY CM IN WRITING OF CONDITIONS DETRIMENTAL TO PROPER COMPLETION OF THE O RECESSED FIXTURE 1. THAT ALL WORK EXECUTED UNDER THIS SECTION WILL BE FREE FROM DEFECTS OF MATERIALS 8. NORMAL POWER SUPERVISION: GREEN LIGHT WITH NAMEPLATE ENGRAVED 'NORMAL SOURCE - WORK. DO NOT PROCEED WITH THE WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE OF AVAILABLE.' IN A MANNER ACCEPTABLE TO THE INSTALLER. THIS WORK. 9. EMERGENCY POWER SUPERVISION: RED LIGHT WITH NAMEPLATE ENGRAVED 'EMERGENCY ID WALL MOUNTED FIXTURE 2. THE CONTRACTOR AGREES TO, AT THE CONTRACTOR'S OWN EXPENSE, REPAIR AND REPLACE ALL SOURCE AVAILABLE.' 1.7 INSTALLATION OF DIESEL ENGINE-ORIVEN GENERATOR SETS _ SUCH DEFECTIVE MATERIALS AND WORK AND ALL OTHER WORK DAMAGED THEREBY WHICH 10. UNASSIGNED AUXILIARY CONTACTS: TWO NORMALLY OPEN SINGLE-POLE, DOUBLE-THROW ll� CEILING MOUNT EXIT LIGHT (W/ DIRECTIONAL ARROWS) _ BECOMES DEFECTIVE DURING THE TERM OF WARRANTY. AGREEMENT DOES NOT INCLUDE CONTACTS FOR EACH SWITCH POSITION, RATED 10 A AT 240-V AC. A. INSTALL ENGINE-DRIVEN GENERATOR UNIT AS RECOMMENDED BY MANUFACTURER. AND ACCORDING TO _jl DAMAGES DONE BY OWNER. 11. TRANSFER OVERRIDE SWITCH: OVERRIDES AUTOMATIC RETRANSFER CONTROL SO AUTOMATIC RECOGNIZED INDUSTRY PRACTICES. COMPLY WITH NFPA AND NEMA STANDARDS PERTAINING TO E. PERMITS, TESTS, CODES AND STANDARDS: TRANSFER SWITCH WILL REMAIN CONNECTED TO EMERGENCY POWER SOURCE REGARDLESS OF INSTALLATION OF ENGINE-GENERATOR SETS AND ACCESSORIES. WALL MOUNT EXIT LIGHT (W/ DIRECTIONAL ARROWS) I. ELECTRICAL CONTRACTOR TO PAY FOR ALL PERMITS AND FEES IN CONNECTION WITH THIS WORK. CONDITION OF NORMAL SOURCE. PILOT LIGHT INDICATES OVERRIDE STATUS. 2. WORK SHALL BE 1N ACCORDANCE WITH APPLICABLE LOCAL, STATE AND NATIONAL CODES AND 12. ENGINE STARTING CONTACTS: ONE ISOLATED, NORMALLY CLOSED AND ONE ISOLATED, NORMALLY B. REMOVE GENERATOR FROM TRAILER IT IS CURRENTLY ATTACHED TO AND SIT ON A LEVEL CONCRETE PAD. ORDINANCES, THE STATE FIRE MARSHAL, AND UTILITY COMPANY REGULATIONS. OPEN, RATED 10 A AT 32-V DC MINIMUM. CONCRETE PAD TO BE PROVIDED BY EC AND BE A MI NI MUM.OF6• THICK AND AT LEAST 6' WI DER 5 YMBOL DEVICES & POWER 3. ELECTRICAL WORK SHALL CONFORM TO'NATIONAL ELECTRICAL LODES, LATEST EDITIONS. AS A 13. ENGINE SHUTDOWN CONTACTS:' TIME DELAY ADJUSTABLE FROM ZERO TO FIVE MII MUTES: THAN THE ENCLOSURE/FUEL TANK ON ALL SIDES. MINIMUM REQUIREMENT. FACTORY SET FOR FIVE MINUTES. INITIATES SHUTDOWN AT REMOTE ENGINE-GENERATOR CONTROLS SWITCH -SPST 3 THREE WAY 4. ALL MATERIAL TO CONFORM WITH APPLICABLE STANDARDS. AFTER RETRANSFER OF LOAD TO NORMAL SOURCE. C. TIGHTEN CONNECTORS AND TERMINALS, INCLUDING SCREWS AND BOLTS, IN ACCORDANCE WITH F. O15CREPANLI ES: PRIOR TO SUBMITTING BID, CONTRACTOR SHALL REFER ANY APPARENT 14. ENGINE-GENERATOR EXERCISER: SOLID-STATE, PROGRAMMABLE-TIME SWITCH STARTS ENGINE- ` EQUIPMENT MANUFACTURER'S PUBLISHED TORQUE TIGHTENING VALUES FOR EOUI PMENT CONNECTORS. DISCREPANCIES OR OMISSIONS TO THE CM FOR CLARIFICATION. THE MORE STRINGENT PROVI SI DNS GENERATOR SET AND TRANSFERS LOAD TO 17 FROM NORMAL SOURCE FOR A PRESET TIME, THEN I WHERE MANUFACTURER'S TOROUI NO REGUI REMENTS ARE NOT INDICATED, TIGHTEN CONNECTORS AND SHALL TAKE PRECEDENCE•.WHERE CODES, SPECIFICATIONS AND DRAWINGS DIFFER WITH ONE RETRANSFERS AND SHUTS DOWN ENGINE AFTER A PRESET COOL-DOWN.PERIOD. INITIATES TERMINALS TO COMPLY WITH TIGHTENING TORQUES SPECI FI EO IN UL STDS 486A, B AND THE RECEPTACLE -SIMPLEX ANOTHER. THE CONTRACTOR SHALL' BID THE MORE EXPENSIVE REQUIREMENT, UNLESS DISCREPANCY EXERCISE CYCLE AT PRESET INTERVALS ADJUSTABLE FROM 7 TO 30 DAYS.' RUNNING PERIODS NATIONAL ELECTRICAL CODE.IS ADDRESSED BY ADDENDUM PRIOR TO BID. ARE ADJUSTABLE FROM 10 TO 30 MINUTES. FACTORY SETTINGS ARE FOR 7-DAY EXERCISE CYCLE, RECEPTACLE - DUPLEX GFI GROUND FAULT INTERRUPT G. SHOP DRAWING SUBMITTALS: 20-MINUTE RUNNING PERIOD, AND 5-MINUTE COOL-DOWN PERIOD. EXERCISER FEATURES D. PROVIDE ALL NECESSARY WIRING AND CONNECTIONS TO ACCESSORIES. WP WEATHERPROOF 1. SUBMIT DRAWINGS FOR FINAL AND OFFICIAL APPROVAL THROUGH THE CM AS LISTED BELOW: INCLUDE THE FOLLOWING: IG ISOLATED GROUND .. A. ENGINEER - 2 COPIES. - EXERCISER TRANSFER SELECTOR SWITCH: PERMITS SELECTION OF EXERCISE WITH AND ' "' B. CM- 2 COPIES. WITHOUT LOAD TRANSFER. 1.8 GROUNDING RECEPTACLE -DOUBLE DUPLEX . I -- C. SUBCONTRACTORCOPIES AS REQUIRED. - PUSH-BUTTON PROGRAMMI NC CONTROL WITH DIGITAL DISPLAY OF SETTINGS. SAME INDICATORS AS SHOWN FOR DUPLEX ADDITIONAL COP1 E$ MAY BE REQUIRED RED BY INDIVIDUAL SECTIONS ONS OF THESE SPECIFICATIONS. - INTEGRAL BATTERY OPERATION OF TIME SWITCH WHEN NORMAL CONTROL POWER IS NOT A. PROVIDE EQUIPMENT GROUNDING CONNECTIONS FOR DIESEL ENGINE-DRIVEN GENERATOR UNITS AS COPIES OF PRICE LIST SHEETS ARE NOT ACCEPTABLE. MANUFACTURER'S NAME AND ADDRESS AVAILABLE. REQUIRED BY CODE. TIGHTEN CONNECTIONS TO COMPLY WITH TIGHTENING TORQUES SPECIFIED IN UL MUST APPEAR ON EACH SHEET. ALL COPIES SHALL BE COMPLETELY LEGIBLE. FAX COPIES 15. PHASE MONITOR: 'FACTORY-WIRED, INTERNAL RELAY CONTROLS TRANSFER SO IT OCCURS ONLY STD 486A TO ASSURE PERMANENT AND EFFECTIVE GROUNDING. O FLOOR DUPLEX RECEPTACLE ARE UNACCEPTABLE. ALL SHOP DRAWINGS NOT BOUND IN DUO-TANG, MEAD OR WHEN THE TWO SOURCES ARE SYNCHRONIZED IN PHASE. RELAY COMPARES PHASE O EQUIVALENT FOLDERS WILL BE REJECTED. RELATIONSHIP AND FREQUENCY DIFFERENCE BETWEEN NORMAL AND EMERGENCY SOURCES AND 1.9 FIELD QUALITY CONTROL. 2. SUBMIT SHOP DRAWINGS FOR THE FOLLOWING SPECIFICATION SECTIONS: 16140, 1 641 5. INITIATES TRANSFER WHEN BOTH SOURCES ARE WITHIN 15 ELECTRICAL DEGREES, AND ONLY IF O 'O J-BOX,J-BOX WALL MOUNTED,4"x4"x2%g"DEEP UNLESS NOTED OTHERWISE 16442. 16445, 16475, 16476, 16481, 16511, AND 16999. TRANSFER CAN BE COMPLETED WITHIN 60 ELECTRICAL DEGREES. TRANSFER IS INITIATED ONLY IF A. START-UP TESTING:3. SHOP DRAWINGS SHALL INCLUDE A COMPLETED SPECIFICATION SHEET OF.ALL EQUIPMENT BOTH SOURCES ARE WITHIN 2 HZ OF NOMINAL FREQUENCY AND 70 PERCENT OR MORE OF O THERMOSTAT BY MC,INSTALLED,WIRED,& CONNECTED BY EC ALONG WITH FABRICATION, INSTALLATION DRAWINGS, SETTING DIAGRAMS, SCHEDULES, NOMINAL VOLTAGE 1. ENGAGE LOCAL EQUIPMENT MANUFACTURER'S REPRESENTATIVE TO PERFORM START-UP AND PATTERNS. TEMPLATES AND SIMILAR DRAWINGS. 0. MATCH TYPE AND NUMBER OF CABLES AND CONDUCTORS TO CONTROL AND COMMUNICATIONS LOAD TESTS UPON COMPLETION OF-INSTALLATION, WITH THE CM IN ATTENDANCE: PROVIDE H. SUBSTANTIAL COMPLETION- REQUIREMENTS OF TRANSFER SWITCHES AS RECOMMENDED BY MANUFACTURER AND AS NECESSARY CERTIFIED TEST RECORD. TESTS ARE TO INCLUDE THE FOLLOWING: $ MANUAL MOTOR DISCONNECT/STARTER SWITCH N 1. AT SUBSTANTIAL COMPLETION OF PROJECT, BE READY TO DEMONSTRATE THE FOLLOWING LIST OF TO ACCOMMODATE EXISTING GENERATOR. PROVIDE RACEWAYS, CONDUCTORS, AND CONNECTIONS M O M ITEMS BELOW. 1F THIS IS NOT POSSIBLE, INFORM THE CM NO LESS THAN 1 WEEK PRIOR TO AS REQUIRED. A. CHECK FUEL, LUBRICATING OIL, AND ANTIFREEZE IN LIQUID COOLED MODELS FOR N y ENGINEER-S VISITATION OF THE SITE FOR SUBSTANTIAL COMPLETION. E. TESTING: TEST TRANSFER-SWITCH PRODUCTS BY OPERATING THEM IN ALL MODES. PERFORM TESTS CONFORMITY TO THE MANUFACTURER'S RECOMMENDATIONS UNDER ENVIRONMENTAL EMERGENCY PUSHBUTTON M M 11 A. PROVIDE CERTIFICATE THAT THE FIRE ALARM SYSTEM HAS BEEN COMPLETED AND RECOMMENDED BY MANUFACTURER UNDER THE SUPERVISION OF MANUFACTURER'S FACTORY- m en TESTED CONDITIONS PRESENT.N ACCORDANCE WITH NFPA PROCEDURES BY MANUFACTURERS AUTHORIZED SERVILE REPRESENTATIVE. CORRECT DEFICIENCIES CI ENGI ES AND REPORT RESULTS IN WRITING. B. TEST, PRIOR TO CRANKING ENGINE FOR PROPER OPERATION, ACCESSORIES THAT NORMALLY C INSECT CONTROL CONNECTION REPRESENTATIVE. RECORD ADJUSTABLE RELAY SETTINGS. FUNCTION WHILE THE SET IS I A STANDBY MODE. O w M B. DEMONSTRATE THAT INSULATED THROAT BUSHINGS HAVE BEEN INSTALLED ON ALL F. TESTING: PERFORM THE FOLLOWING FIELD OUALITY-CONTROL TESTING UNDER THE SUPERVISION OF THE C. CHECK, DURING START-UP TEST MODE, FOR NORMAL AND EMERGENCY LINE-TO-LINE CONDUITS THAT ARE STUBBED ABOVE LAY-IN CEILINGS OR AT EQUIPMENT. MANUFACTURER'S FACTORY-AUTHORIZED SERVICE REPRESENTATIVE IN ADDITION TO TESTS VOLTAGE AND PHASE ROTATION. PC PHOTOCELL -a0 C. DEMONSTRATE THAT ALL LAY-IN LIGHT FIXTURES INSTALLED IN CEILING GRIDS ARE RECOMMENDED BY THE MANUFACTURER: D. TEST, BY MEANS OF SIMULATED POWER OUTAGE, AUTOMATIC START-UP BY REMOTE- a N SUPPORTED WITH CLIPS AND HAVE 12 GAUGE WIRES FROM DIAGONAL CORNERS TO 1. BEFORE ENERGIZING EQUIPMENT, AFTER TRANSFER-SWITCH PRODUCTS HAVE BEEN INSTALLED. AUTOMATIC STARTING, TRANSFER OF LOAD, AND AUTOMATIC SHUTDOWN. PRIOR TO THIS STRUCTURE. A. MEASURE INSULATION RESISTANCE PHASE-TO PHASE AND PHASE-TO-GROUND WITH TEST ADJUST, FOR PROPER SYSTEM COORDINATION, TRANSFER SWITCH TIMERS. MONITOR ® SPECIAL PURPOSE CONNECTION WORK AS NOTED tb �. D. DEMONSTRATE TH P RA E 0 E TI ON AITEMSND TEST OF THE EMERGENCY LIGHTING SYSTEM. INSULATION-REST STANCE TESTER. INCLUDE EXTERNAL ANNUNCIATION AND CONTROL THROUGHOUT THE TEST, ENGINE TEMPERATURE, OIL PRESSURE, BATTERY CHARGE LEVEL, E. ALL ELECTRICAL SYSTEMS AND FALL SPECIFIED SHALL BE INSTALLED AND OPERATIONAL. CIRCUITS. USE TEST VOLTAGES AND PROCEDURE RECOMMENDED BY MANUFACTURER. GENERATOR VOLTAGE, AMPERES, AND FREQUENCY. 'r�, ELECTRIC MOTOR CONNECTION � U. F. DEMONSTRATE THE OPERATION OF ALL EMERGENCY POWER SYSTEMS INCLUDING MEET MANUFACTURER'S SPECIFIED MINIMUM RESISTANCE. GENERATORS, UNINTERUPTIBLE POWER SUPPLIES AND INVERTER SYSTEMS. B. CHECK FOR ELECTRICAL CONTINUITY OF CIRCUITS AND FOR SHORT CIRCUITS. 2. UPON COMPLETION OF INSTALLATION DEMONSTRATE CAPABILITY AND COMPLIANCE OF SYSTEM I. PROJECT CLOSE-OUT RECORD DOCUMENTS: C. INSPECT FOR PHYSICAL DAMAGE: PROPER INSTALLATION AND CONNECTION: AND WITH REQUIREMENTS. WHERE POSSIBLE, CORRECT MALFUNCTIONING UNIT AT SITE, THEN RETEST TO 1. PROVIDE 2 FULL SIZE SETS PONE FOR ENGINEER AND ONE FOR OWNER). INDICATE THE INTEGRITY OF BARRIERS, COVERS, AND SAFETY FEATURES. Lo COMBINATION STARTER U O DEMONSTRATE COMPLIANCE: OTHERWISE. REMOVE AND REPLACE WITH NEW UNIT,T, AND PROCEED 0 FOLLOWING INSTALLED CONDITIONS: D. VERIFY THAT MANUAL TRANSFER WARNINGS ARE PROPERLY PLACED. WITH RETESTING. INITIAL TESTING AND RETESTING TO BE AT NO COST TO OWNER. A. ACTUAL LOCATION OF ALL ELECTRICAL GEAR/FEEDERS, PANEL/MOTOR/SPECIAL FUTURE PMENT E. PERFORM MANUAL TRANSFER OPERATION. L❑ DISCONNECT SWITCH FEEDERS, ALL MAJOR UNDERGROUND OR CONDUITS, ALL CONDUIT SNUBS FOR FUTURE USE, 2. AFTER ENERGIZING CIRCUITS, DEMONSTRATE INTERLOCKING SEQUENCE AND OPERATIONAL 3. UPON COMPLETION OF TESTING, COMPLETELY Fl LL THE SUB-BASE FUEL TANK. L. ANY CHANGE IN BRANCH CIRCUITRY FROM DRAWINGS, KEY JUNCTION BOXES AND PULL FUNCTION FOR EACH SWITCH AT LEAST THREE TIMES. M BOXES NOT INDICATED WIN ON DRAWINGS, ANY CONTROL LOCATIONS OR INDICATOR LIGHTS A. SIMULATE POWER FAILURES OF NORMAL SOURCE TO AUTOMATIC TRANSFER SWITCHES END OF SECTION ® CONTACTOR O N^NOT SHOWN ON DRAWINGS. AND OF EMERGENCY SOURCE WITH NORMAL SOURCE AVAILABLE. :�I 4 S. ADDENDUM ITEMS, CHANGE ORDER ITEMS AND ALL CHANGES MADE TO DRAWINGS B. SIMULATE LOSS OF PHASE-TO-GROUND VOLTAGE FOR EACH PHASE OF NORMAL SOURCE. ® CIRCUIT BREAKER O �.Ly UJ co FROM B10DING PHASE THROUGH TO PROJECT COMPLETION. C. VERIFY TIME-DELAY SETTINGS. = O C. ACTUAL EQUIPMENT AND MATERIALS INSTALLED. WHERE MANUFACTURER AND CATALOG D. VERIFY PICKUP AND DROPOUT VOLTAGES BY DATA READOUT OR INSPECTION OF CONTROL 0 NUMBER ARE INDICATED ON DRAWINGS, GENERALLY OR IN FIXTURE OR EQUIPMENT SETTINGS. G PANELBOARD V l SCHEDULES, CHANGE TO REFLECT ACTUAL PRODUCTS INSTALLED. E. PERFORM CONTACT-RESISTANCE TEST ACROSS MAIN CONTACTS AND CORRECT VALUES Z ' D. CHANGE SERVICE PANEL AND BRANCH PANEL BREAKER LOCATIONS AND SCHEDULES EXCEEDING 500 MI CROHMS AND VALUES FOR ONE POLE DEVIATING BY MORE THAN TO REFLECT ACTUAL INSTALLED CONDITIONS. 50 PERCENT FROM OTHER POLES. ~y O in 0 J. PROJECT CLOSE-OUT MAINTENANCE MANUALS. F. VERIFY PROPER SEQUENCE AND CORRECT TIMING OF AUTOMATIC ENGINE STARTING, e-_ 1. PREPARE 3 COPIES (ONE FOR ENGINEER, TWO FOR OWNER). PROVIDE HEAVY DUTY, DURABLE TRANSFER TIME DELAY, RETRANSFER TIME DELAY ON RESTORATION OF NORMAL POWER, SYMBOL ABBREVIATIONS AND MISCELLANEOUS cc°- 3-RING VINYL COVERED LOOSE-LEAF BINDER FOR EACH MANUAL SIZED TO RECEIVE 8.5 INCH AND ENGINE COOL-DOWN AND SHUTDOWN SEQUENCE. BY 11 INCH PAPER. PROVIDE A CLEAR PLASTIC SLEEVE ON THE SPINE TO HOLD LABELS AND G. ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN OWNER'S PERSONNEL TO v ) POCKETS IN THE COVER TO RECEIVE FOLDED SHEETS. IN MANUAL, INCLUDE ALL SHOP ADJUST, OPERATE, AND MAINTAIN TRANSFER SWITCHES AND RELATED EQUIPMENT AS SPECIFIED ATS AUTOMATIC TRANSFER SWITCH DRAWINGS, INSTALLATION/OPERATION/MAINTENANCE DATA FURNISHED WITH ELECTRICAL BELOW: ELECTRICAL CONTRACTOR EQUIPMENT, VOICE/DATA TEST REPORTS, AND LETTERS FROM MANUFACTURERS 1. TRAIN OWNER'S MAINTENANCE PERSONNEL ON PROCEDURES AND SCHEDULES FOR STARTING EC REPRESENTATIVES THAT THE FIRE ALARM CALL SYSTEM HAS BEEN COMPLETED AND TESTED TO AND STOPPING, TROUBLESHOOTING, SERVICING, AND MAINTAINING EQUIPMENT. MC MECHANICAL CONTRACTOR SATISFY REOUIREMENTS/CODES. LIST PROJECT NAME, DATE, AND CONTRACTOR'S NAME, 2. SCHEDULE TRAINING WITH OWNER, THROUGH THE CM. WITH AT LEAST SEVEN DAYS' ADVANCE ADDRESS AND TELEPHONE NUMBER. INCLUDE INDEX SHEET FOR EACH SPECIFICATION NOTICE. GC GENERAL CONTRACTOR SECTION INDICATING DER PMENT, WITH SUPPLIER AND SUPPLIER'S TELEPHONE NUMBER. 16442 - PANELBOARDS C CONDUIT ' PROVIDE TABBED DIVIDERS INDICATING MAJOR GROUPINGS OF EQUIPMENT. A. MANUFACTURER: SIEMENS. SOUARE-D, OR GE. I V 2. TURN OVER TO OWNER ALL SPARE EQUIPMENT AND DEVICES SPECIFIED AND SHOWN. K. SUPPORTING EQUIPMENT: B. LOAD CENTERS ARE NOT ACCEPTABLE. GND GROUND /Y 1. UNLESS OTHERWISE INDICATED, FASTEN ELECTRICAL ITEMS AND THEIR SUPPORTING HARDWARE `-4 �j SECURELY TO THE BUILDING STRUCTURE, INCLUDING CONDUITS, RACEWAYS, CABLES, CABINETS, C. PANELBOARDS SHALL HAVE COPPER BUS, 200% RATED NEUTRAL AND GROUND BARS. BREAKERS SHALL AFF ABOVE FINISHED FLOOR �.... MEANSPANEL OARDS, BOXES, DISCONNECT SWITCHES, AND CONTROL COMPONENTS. FASTEN BY BE BOLT ON TYPE. MAIN BREAKERS, WHEN CALLED FOR, SHALL BE FACTORY INSTALLED AND BUSSED. W/ WITH MEANS OF WOOD SCREWS OR SCREW-TYPE NAILS ON WODO, TOGGLE BOLTS . HOLLOW MASONRY UNITS. CONCRETE INSERTS OR EXPANSION BOLTS ON CONCRETE OR SOLID MASONRY, D. PROVIDE FRAMED, TYPED CIRCUIT SCHEDULES FOR ALL PANELBOARDS WITH IDENTIFICATION OF ITEMS TK TOE KICK � X AND MACHINE SCREWS, WELDED THREADED STUDS, OR SPRING-TENSION CLAMPS ON STEEL. CONTROLLED BY EACH INDIVIDUAL BREAKER. INDICATE ROOM NUMBERS OF ITEMS CONTROLLED OR AC AC.UNIT THREADED STUDS DRIVEN BY A POWER CHARGE AND PROVIDED WITH LOCK WASHERS AND ROOM NAME WHERE APPROPRIATE FOR OWNER'S CONVENIENCE. NUTS MAY BE USED INSTEAD OF EXPANSION BOLTS AND MACHINE OR WOOD SCREWS. DO REF REFRIGERATOR NOT WELD CONDUIT, PIPE STRAPS, OR ITEMS OTHER THAN THREADED STUDS TO STEEL E. UPDATE CIRCUIT SCHEDULES OF EXISTING PANELS TO REFLECT NEW LOADS BEING FED. STRUCTURES. IN PARTITIONS OF LIGHT STEEL CONSTRUCTION, USE SHEET METAL SCREWS. ALL 1�-L-4 DEVICE BOXES IN SHEETROCK WALLS WILL BE TIGHT BEFORE, DURING AND AFTER INSTALLATION F. EXISTING PANELS AND GEAR ARE SIEMENS. a,b,c etc. SWITCH DESIGNATION OF SHEETROCK. 16445 • TRANSIENT VOLTAGE SURGE SURPRESSION(TVSS) 2. PROVIDE SUPPORTS FOR ELECTRICAL ITEMS IN ACCORDANCE WITH TH NEC AND ALL OTHER A. TVSS PROTECTION: PROVIDE TVSS PROTECTION WHERE INDICATED. TVSS UNIT SHALL BE LISTED UG UNDERGROUND APPLICABLE CODES. UNDER ULI449, 2ND EDITION AND MANUFACTURED LATER THAN AUGUST 1998. PROTECTION SHALL r^ 3. CONTRACTOR RESPONSIBLE FOR PROVIDING WATERTIGHT CONDUIT PENETRATIONS AT ALL BE LINE-TO-NEUTRAL. NEUTRAL-TO-GROUND PROTECTION IS NOT REQUIRED. IT SHALL BE LISTED TO AG ABOVE GROUND ^'v J WATERTIGHT WALLS, FLOORS ROOFS AND MEMBRANES. CONTRACTOR ALSO RESPONSIBLE TO CONNECT TO THE FULL AMPERAGE AVAILABLE. IT SHALL BE LISTED FOR 48OV. VISUAL AND AUDIBLE WP WEATHER PROOF L.L.. MAINTAIN FIRE RATING OF WALLS, FLOORS, ROOFS AND MEMBRANES PENETRATED. INDICATION SHALL BE PROVIDED FOR NOTIFICATION OF TVSS FAILURE. INSTALL PER MANUFACTURER-S W L. ELECTRICAL I DENT/F1 CAT]ON: RECOMMENDATIONS.- VERUR BNiL-2,4,6 CIRCUIT DESIGNATION,PANELBOARD BNiL,CIRCUITS 2,4,6. 1. APPLY CIRCUIT/CONTROL/ITEM DESIGNATION LABELS OF ENGRAVED PLASTIC LAMINATE FOR 16475 - OVER CURRENT PROTECTION DEVICES 1/E5.2 INDICATES DETAIL 10N SHEET E5.2 V"I DISCONNECT SWITCHES, BREAKERS, PUSHBUTTONS, PILOT LIGHTS, FA DUCT DETECTION, MOTOR A. FUSES: �--1 w STARTERS, PANELBEXPOSED ANDCES MAIN CONTROL PANEL FOR ALL OTHER ELECTRICAL SYSTEMS. 1. PROVIDE AS SCHEDULED. EF EXHAUST FAN O 2. IDENTIFY EXPOSED OR ACCESSIBLE RACEWAY JUNCTION BOXES WITH SPRAY PAINT. APPLY 2. MANUFACTURER: BUSSMAN, COULD, LITTLEFUSE OR BRUSH. COLORS AS FOLLOWS: 16476 - CIRCUIT AND MOTOR DISCONNECT UH UNIT HEATER A. FIRE ALARM LIGHTING RED. A. MANUFACTURER: SAME AS PANELBOARD MANUFACTURER. U B. EMERGENCY LIGHTING AND POWER: ORANGE. CF CEILING FAN C. VOICE/DATA SYSTEM: GREEN. B. DISCONNECTS SHALL BE 250 VOLT OR 600 VOLT HEAVY DUTY TYPE WITH CLASS R REJECTION D. SECURITY SYSTEM: YELLOW. FEATURE WHEN REQUIRED TO BE FUSIBLE. PROVIDE NEMA 3R ENCLOSURE FOR EXTERIOR EWC ELECTRIC WATER COOLER 3. IDENTIFY POWER JUNCTION AND PULL BOXES WITH PERMANENT MARKER, INDICATING VOLTAGE LOCATIONS. SERVICE SWITCHES SHALL BE UL LISTED FOR USE AS SERVICE EQUIPMENT. O W AND CONTAINED CIRCUITS. 4. IDENTIFY UNDERGROUND EXTERIOR ELECTRICAL CIRCUITS BY INSTALLATION OF CONTINUOUS C. PROVIDE AS REQUIRED. O1 SHEET WORK NOTE. UNDERGROUND PLASTIC MARKER, 6 - 8 INCHES BELOW GRADE. 16481 - MOTOR CONTROLLERS W 16030 - REMODEL WORK A. TOGGLE SWITCH STARTERS TO BE EQUAL TO SOUARE-D FG SERIES. HOME RUN TO PANELS. r^ A. THE CONTRACTOR SHALL CAREFULLY EXAMII NE THE DRAWINGS AND SPECIFICATIONS. VISIT THE v I PROJECT SITE. AND MAKE NOTE OF ALL EXISTING CONDITIONS, DIMENSIONS AND LIMITATIONS PRIOR TO B. UNLESS SCHEDULED OTHERWISE, 1/2 HORSEPOWER OR LESS SINGLE-PHASE MOTORS SHALL HAVE BID AND MAKE ALLOWANCES THERETO. MANUALLY OPERATED TOGGLE SWITCH WITH INTEGRAL THERMAL OVERLOAD PROTECTION. PROVIDE �� CONDUIT CONCEALED IN CEILING OR WALL B. NO CHANGE ORDERS WILL BE ISSUED FOR CONTRACTOR'S FAILURE TO VISIT SITE, REMODEL WORK PILOT LIGHT FOR MANUAL STARTERS NOT IN SIGHT FROM MOTOR. PROVIDE TOGGLE SWITCH STARTERS NECESSARY FOR A COMPLETE R DIFFICULTY ON OF SYSTEMS SHOWN, AND DUE,TO CONTRACTOR'S LACK OF AS REQUIRED. U UNDERSTANDING OF AMOUNT OR DIFFICULTY OF WORK INVOLVED. 16511 - LIGHTING C. THE CONTRACTOR SHALL ALSO NOTIFY ALL CORPORATIONS, 'COMPANIES, INDIVIDUALS OR LOCAL A. MANUFACTURER, MODEL, STYLE, COLOR, SIZE, ETC.. AS SCHEDULED. IF NO COLOR HAS BEEN SYMBOL COMMUNICATIONS U AUTHORITIES OWNING, OR HAVING JURISDICTION OVER EXISTING UTILITIES AND SERVICES WHICH SELECTED, PROVIDE FIXTURE WITH THE STANDARD FINISH AS PUBLISHED BY THE MANUFACTURER. ^ �y Lu INTERFERE IN ANY MANNER WITH THE EXECUTION OF THE WORK UNDER THIS CONTRACT, AND SHALL ALL FIXTURES TO BE SUPPLIED AS COMPLETE, HOUSING, SOCKETS, LAMP HOLDERS, INTERNAL �I.� REMOVE. RELOCATE OR PROTECT SUCH UTILITIES OR EQUIPMENT AS REQUIRED BY THE PARTIES HAVING WORKING, WIRE GUARDS, LENS GUARDS, DIFFUSING MATERIALS OR LENSES, PENDANTS, HANGERS,JURISDICTION OVER SAME. CANOPIES, ALIGNERS, END CAPS, BALLASTS AND EMERGENCY BATTERY PACKS, PLASTER FRAMES, ®s Q5 SPEAKER W D. IF EXISTING ACTIVE OR NONACTIVE SERVICES (WHICH MAY NOT BE SHOWN ON PLANS) ARE RECESSING BOXES, HOLD DOWN CLIPS, ANCHOR BOLTS, ETC. ENCOUNTERED THAT REQUIRE RELOCATION OR DISCONNECTING, THE ELECTRICAL CONTRACTOR SHALL El PUSH BUTTON MAKE WRITTEN REQUEST FOR DECISION ON PROPER HANDLING OF THE SERVICES. THE ELECTRICAL B. INSTALL FIXTURES IN ACCORDANCE WITH NEC AND ALL OTHER APPLICABLE CODES. INSTALL PLUMB ^' CONTRACTOR SHALL NOT PROCEED WITH THE WORK UNTIL SO AUTHORIZED BY THE CM. AND TRUE, FREE OF LIGHT LEAKS, WARPS, DENTS AND OTHER IRREGULARITIES. 1Q LOW VOLTAGE TRANSFORMER E. WHEN AREAS OF THE EXISTING BUILDINGS ARE ADJACENT TO THE AREA OF CONSTRUCTION 1N WHICH O w U L..L.. WORK IS GOING ON AND ARE OCCUPIED, THEN THIS CONTRACTOR SHALL ARRANGE THE WORK SO AS TO C. LAMPS: O REDUCE TO A MINIMUM THE PERIODS OF INTERRUPTION OR OUTAGES 1N THE VARIOUS SERVICES. 1. MANUFACTURERS: GE, PHILLIPS, SYLVANIA, VENTURE. MASTERC MP OLOR AND EYE-LA . HORN F. NOT LESS THAN ONE WEEK BEFORE ANY SYSTEM 1S TO BE PUT OUT OF SERVICE, THE CONTRACTOR 2. FLUORESCENT LAMPS SHALL BE PROVIDED AS SCHEDULED. LAMP WATTAGE NOT TO EXCEED SHALL NOTIFY AND COORDINATE WITH OTHER TRADES AND THE OWNER OF SUCH NECESSITY INCLUDING MANUFACTURER'S RECOMMENDATIONS. ALL LAMPS OF A GIVEN TYPE TO BE PROVIDED BY Cd THE EXTENT OF THE WORK TO BE DONE DURING THE OUTAGE, POSSIBLE LENGTH OF TIME REQUIRED FOR THE SAME MANUFACTURER. l THAT PHASE OF THE WORK, AND THE DESTIN RED TIME AT WHICH THE OUTAGE IS TO BEGIN. 3. PROVIDE SPARE LAMPS EQUAL TO 10 PERCENT AND NOT LESS THAN ONE FOR EACH TYPE SYMBOL FIRE ALARM �-'-i �1 G. BALANCE ADDITIONAL LOADS TO EXISTING CIRCUITRY RE BETWEEN PHASES. FURNISH A REVISED, TYPED SPECIFIED. PANEL DIRECTORY ON EXISTING PANELBOARDS WHERE LOADS HAVE BEEN ADDED OR CHANGED ON D. BALLASTS: THIS PROJECT. 1. MANUFACTURERS: GE, MOTOROLA, ADVANCE AND UNIVERSAL. H. CAREFULLY LAY OUT ALL WORK IN ADVANCE TO MINIMIZE CUTTING, CHANNELING OR DRILLING. WHERE 2..FLUORESCENT BALLASTS TO BE ELECTRONIC, INSTANT START TYPE WITH NO MORE THAN 20 FIRE ALARM STROBE NECESSARY, ALL CUTTING AND PATCHING SHALL BE DONE 1N A MANNER APPROVED BY THE PERCENT THO AND UL LISTED. �••� M ARCHITECT. DO NOT ENDANGER THE STABILITY OF THE STRUCTURE. RESTORE ANY DAMAGED 3. HID BALLASTS SHALL HAVE HIGH POWER FACTOR, UL LISTED AND CONSTANT WATTAGE AUTO- 11-11 vJ SURFACES TO ORIGINAL CONDITIONS. CONTRACTOR AT FAULT TO ASSUME ALL COSTS. TRANSFORMER. FIRE ALARM HORN AND STROBE 1. REMOVE OR RELOCATE EXISTING CONDUITS, WIRES, EOUIPMENT, DEVICES OR FIXTURES INDICATED 4. EMERGENCY BACK-UP BALLASTS SHALL PROVIDE FULL-LUMEN OUTPUT FOR ALL LAMPS WITHIN ON DRAWINGS AND AS REQUIRED BY REMODEL OPERATIONS. WHERE THE REUSE OF EXISTING THE FIXTURE. © FIRE ALARM MANUAL PULL STATION CONDUITS, WIRES, DEVICES, OR FIXTURE IS PERMITTED, VERIFY THAT WIRING IS CONTINUOUS. EXISTING 16721 - FIRE ALARM , OUTLETS OR JUNCTION . WHERE SHALL NOT BE RENDERED INACCESSIBLE BY STRUCTURAL CHANGES A. THE EXISTING.FIRE ALARM SYSTEM 15 RADI ONI CS. so FIRE ALARM SMOKE DETECTOR MADE TO THE BUILDING. WHERE EXISTING WALLS ARE BEING FURRED OUT OR REFINISHED, EXTEND EXISTING OUTLETS AND DEVICES TO NEW SURFACE AS REQUIRED. S. THE EXISTING CONTROL PANEL IS MODEL -072128. qj J. EXISTING EOUIPMENT WHICH IS INDICATED AS BEING REMOVED AND NOT INDICATED FOR RE-USE �° FIRE ALARM HEAT DETECTOR wee SHALL BE DISPOSED OF UNLESS STATED OTHERWISE. LIGHT FIXTURE BALLASTS MAY CONTAIN PCB'S C. PHOTOELECTRIC SMOKE DETECTORS. INTELLIGENT ADDRESSABLE PHOTOELECTRIC SMOKE W AND SHALL BE DISPOSED OF ACCORDING TO ENVIRONMENTAL REGULATIONS. DETECTOR TO EMPLOY LIGHT SCATTERING PRINCIPLE OF OPERATION. SMOKE DETECTOR SHALL ALARM ® FIRE ALARM DUCT SMOKE DETECTOR 16060 - GROUNDING WHEN SMOKE OBSCURATION LEVEL IN THE DETECTION CHAMBER REACHES THE 3 PERCENT PER p $96 A. INSTALL SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTORS FOR FEEDER AND BRANCH FOOT LEVEL. CIRCUITS IN DING CONDUCTORS. WITH NEC ARTICLE 250. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR -Q FIRE ALARM - ANNUNCIATOR 3. SIZING GROUNDING CONDUCTORS. D. HEAT DETECTORS: INTELLIGENT ADDRESSABLE. B. PROVIDE •6 AWG MINIMUM GREEN INSULATED COPPER CONDUCTOR IN RACEWAY FROM 1. FIXED TEMPERATURE TYPE, 135 DEG F. . GROUNDING ELECTRODE SYSTEM TO EACH VOICE/DATA,CE/DATA, i I ALARM AND COMMUNICATIONS SYSTEM'S 2. RATE OF RISE TYPE. 135 DEG F. ® FIRE ALARM -FIRE SMOKE DAMPER SS\OIL fiy TERMINAL BOARD, CABINET OR EQUIPMENT LOCATION. OAF, p�57ER fo C� C. SYSTEM GROUND: MAINTAIN INTEGRITY OF EXISTING GROUNDING SYSTEM. E. DUCT DETECTION: INTELLIGENT ADDRESSABLE PHOTOELECTRIC WITH SAMPLING TUBES. PROVIDE D. SEE DRAWINGS FOR ADDITIONAL GROUNDING REQUIREMENTS. REMOTE TEST STATION ON WALL ADJACENT TO UNIT. LOCATE AT SUITABLE LOCATION IN RETURN AIR 16120 - WIRES AND CABLES STREAM PRIOR TO EXHAUSTING FROM THE BUI LOI NO OR BEI NO.01 LUTEO BY OUTSIDE AIR, AND AT A. ALL CONDUCTORS SHALL 8E PROVIDED AND INSTALLED 1N ACCORDANCE WITH NEC, NEMA, UL SUITABLE LOCATION IN MAIN SUPPLY DUCT ON THE OTHER SIDE OF THE FILTERS. COMPLY WITH '96 META ATS-1995. AND ALL OTHER APPLICABLE CODES. ALL CONDUCTORS SHALL BE COPPER AND UMO SECTION 608, NFPA 72, NFPA 90A AND MANUFACTURER'S INSTRUCTIONS. PROVIDE Q O Q G INSTALLED IN CONDUIT, UNLESS OTHERWISE NOTED. ALUMINUM CONDUCTORS SHALL NOT BE USED. FAN SHUTDOWN RELAY WITHIN 3 FEET OF AIR HANDLER STARTER INTEGRATED WITH FACP FOR I �lvl,//ovlJ�B. MII NI NUM CONDUCTOR SIZE FOR LIGHT AND POWER SHALL BE 12 AWG COPPER. MINIMUM SHUTDOWN OF AIR HANDLER UNDER ALARM. !/ CONDUCTOR SIZE FOR CONTROL SHALL BE e14 AWG COPPER UNLESS OTHERWISE REQUIRED. •10 9,411 G AWG AND SMALLER SHALL BE SOLID WIRE AND 8 AWG AND LARGER SHALL BE STRANDED. F. PREACTION SYSTEM: A PRE-ACTION SYSTEM IS TO BE PROM QED FOR THE UPS AND DATA 4N C. TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS, INCLUDING SCREWS AND BOLTS, IN ACCORDANCE CENTER ROOMS. PANEL TO BE PROVIDED BY THE FIRE SPRINKLER CONTRACTOR. THE FIRE ALARM WITH MANUFACTURER'S PUBLISHED TORQUE TIGHTENING VALVES OR AS SPECIFIED IN UL CODES. CONTRACTOR TO INSTALL AND CONNECT AS REQUIRED. ' R BRA D. COLOR CODE SECONDARY SERVICE, FEEDER, AND BRANCH CIRCUIT CONDUCTORS WITH FACTORY APPLIED COLOR AS FOLLOWS: G. MAIN VALVE SUPERVISORY SWITCHES SHALL BE FURNISHED BY OTHERS AND WIRED BY ELECTRICAL 208Y/120BLACKVOLTS AHASE BRO0277 VOLTS CONTRACTOR, CTA JOB NO. RED B PURPLE H. FLOW SWITCH SHALL BE FURNISHED AND INSTALLED BY OTHERS AND WIRED BY ELECTRICAL LIGHTING FIXTURE SCHEDULE BLUE C YELLOW CONTRACTOR. FIXTURE MOUNTING DELLCC WHITE NEUTRAL GRAY LAMP FIXTURE REMARKS 11 GREEN GROUND GREEN I. PROVIDE CONNECTIONS AS RAND TAD TO NEW FIRE SPRINKLER EQUIPMENT. THIS INCLUDES, BUT TYPE MANUFACTURER CATALOG NUMBER LOCATION TYPE HEIGHT TYPE NO. VOLTAGE 16130 - RACEWAYS AND BOXES IS NOT LIMITED TO: FLOW AND TAMPER SWITCHES AND AIR COMPRESSORS FOR THE PRE-ACTION DROWN CHECKED A. CONDUIT RACEWAY: SYSTEM. 1A METALUX 2EP3CX3325381EB82 CEILING LAY-IN F32T8/SP35 3 277 2x4 PARABOLIC W/2 BALLASTS 1..INDOORS. USE THE FOLLOWING, UNLESS OTHERWISE STATED: Kee Slw A. CONCEALED: EMT. J. NOTIFICATION CIRCUITS SHALL MATCH THE EXISTING CONFIGURATION. CONDUCTORS SHALL BE SIZED ME METALUX 2EP3GX332S361EB82 CEILING LAY-IN F32T8/SP35 3 277 2x4 PARABOLIC W/ EM BATTERY BACK-UP. (SEE NOTE ><1) DATE o B. EXPOSED: EMT, IMC OR RMC. AS REGUI RED AND BE ENCLOSED IN EMT. C. CONNECTION TO VIBRATING EOUIPMENT: FLEXIBLE METAL CONDUIT. iB METALUX 2EP3GX332S361EB81 CEILING LAY-IN F3278/SP35 3 277 2x4 PARABOLIC W/ iBALLAST $ 2. OUTDOORS, USE THE FOLLOWING, UNLESS OTHERWISE STATED: K. PROVIDE A LETTER OF VERIFICATION THAT THE FIRE ALARM SYSTEM HAS BEEN COMPLETED AND Im/'a/0I A. CONCEALED: RMC OR IMC. TESTED IN ACCORDANCE WITH NFPA PROCEDURES BY MANUFACTURER'S REPRESENTATIVE. 1BE METALUX 2EP3GX332S361EB81 CEILING LAY-IN F32T8/SP35 3 277 2x4 PARABOLIC W/EM BATTERY BACK-UP. (SEE NOTE •1) B. EXPOSED: D, OR IMC. LETTER TO BE INCLUDED WITH AS-BUILT MANUALS. 2A CORELITE NOTE 4,7 CEILING CABLENOTE 6 F32T8/SP35 2 277 8'DIRECTANDIRECT FIXTURE - SHEET TI LE C. UNDERGROUND: SCHEDULE 80 PVC. • D. CONNECTION TO VIBRATING EQUIPMENT: LIQUID TIGHT FLEXIBLE CONDUIT. L. SEE DRAWINGS FOR ADDITIONAL INFORMATION. 2AE CORELITE NOTE 4.7 CEILINGCARLE NOTE'6 F32T8/SP35 2 277 8-DIRECT/INDIRECT FIXTURE W/ EM BATTERY BACK-UP. (SEE NOTE #1) ; 3. ENT, MC CABLE AND UNLESS CABLE NOT ALLOWED. 28 CORELITE NOTE 5.7 CEILING CABLENOTE B F32T8/SP35 2 277 4'DIRECT/INDIRECT FIXTURE. ELECTRICAL � 4. CONCEAL CONDUIT, UNLESS OTHERWISE NOTED OR EXPOSED IN EQUIPMENT ROOMS. ALL M. UNLESS IDEE0 OTHERWISE, ALL FIRE ALARM DEVICES, EQUIPMENT, WIRING, AND CONNECTIONS TO CONDUIT SHALL HAVE INSULATED GROUND WIRE INSTALLED. DO SIONOT INSTALL CONDUIT BE PROVIDED BY EC. 4A METALUX BAU232E881WH WALL SURFACE NOTE 2 F32T8/SP35 2 277 4'WALL BRACKET SPECS,LEGEND EMBEDDED IN SLABS. EMT FITTINGS SHALL BE STEEL, COMPRESSION OR SET SCREW TYPE. ALL RACEWAYS SHALL BE INSTALLED AND SUPPORTED IN ACCORDANCE WITH NEC AND N. TRAINING: TRAIN OWNER'S PERSONNEL A MINIMUM OF 4 HOURS. SCHEDULE ONE WEEK 1N F32T8/SP35 2 277 4'WALL BRACKET W/•EM BATTERY BACK-UP (SEE NOTE #,> I d SCHEDULES APPLICABLE CODES. ADVANCE. ' 4AE METALUX BAU232EB81WH WALL SURFACE NOTE 2 q 5. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SIZING ALL CONDUITS BRANCH CIRCUIT AND 167E4 - SECURITY SYSTEM 5A METALUX SA232AEB81 CEILING SURFACE F32T8/SP35 2 277 FEEDER CONDUITS. A. PROVIDE ROUGH-INS/EMT RACEWAYS/CONDUCTORS AS CALLED OUT ON DRAWINGS AND IN B. OUTLET BOXES: ACCORDANCE WITH'SPECIFICATIONS. DEVICES AND LV CONNECTION OF DEVICES BY EQUIPMENT 1X METALUX CX717ORW NOTE 3 NOTE 3 LED ALOT 277 EXIT SIGNS W/RED LETTERS SHEET 1. CONFORM TO UL 514A, 'METALLIC BOXES, ELECTRICAL', AND UL 5148, 'FITTINGS FOR SUPPLIER. CONDUIT AND OUTLET BOXES.' OUTLET BOXES SHALL BE METALLIC AND INSTALLED FLUSH 1N 16740 - VOICE/DATA NOTES m ALL AREAS, EXCEPT MECHANICAL ROOMS, ABOVE LAY-IN CEILINGS,' OR AS OTHERWISE A. VOICE/DATA ROUGH-INS: PROV1'DE 2-1/8-INCH DEEP 1-GANG ROUGH-INS WITH 3/4-INCH CONDUIT 1 NO[LATED. MINIMUM S1 ZE TO 8E 4 INCHES SQUARE X 2-1/8 INCHES DEEP. BOXES SHALL STUBBED TO CEILING SPACE WITH A 90 DEGREE BEND AND INSULATED THROAT BUSHING, UNLESS i. SEE SPECIFICATIONS FOR EMERGENCY BATTERY BACK-UP BALLAST REQUIREMENTS. BE OF TYPE. SHAPE.'SIZE AND DEPTH TO SUIT EACH LOCATION AND APPLICATION. ALL FITTINGS OTHERWISE STATED. 2. CENTER FI%TURFS BETWEEN BOTTOM OF CEILING AND TOP OF MIRROR. SHALL BE STEEL. 3. WALL/CEILING MOUNT PER DRAWINGS. IF WALL MOUNTED,CENTER 12"-18"ABOVE DOOR OPENINGS. S C. PULL AND JUNCTION BOXES: - 1. COMPLY WITH E. 5B, 'ELECTRICAL CABINETS AND BOXES'. FOR BOXES OVER L B CUBIC 4. 8'-0"CORELITE "CLASS A FULL PERF"LIGHT FIXTURE. FIXTURE TO BE WHITE IN COLOR. { € INCHES VOLUME. BOXES SHALL HAVE SCREWED OR BOLT-ON LOVERS AND SHALL BE SUITABLE 5. 4'-O"CORELITE "CLASS A FULL PERF"LIGHT FIXTURE. FIXTURE TO BE'WHI7E IN COLOR.FOR THE INTENDED APPLICATION. 6: SEE DRAWINGS FOR MOUNTING HEIGHT m D. ALL MATERIALS SHALL BE UL LISTED, APPROPRIATE FOR INTENDED APPLICATION. ENTIRE RACEWAY 7. PROVIDE END-TO-END MOUNTING AS INDICATED ON DRAWINGS. ' ti SYSTEM SHALL BE IN ACCORDANCE WITH NEC. NFPA, ANSI, NEMA, UL, AND ALL OTHER APPLICABLE CODES. .. '. a _ . , . , - a SHEET WORK NOTES: O MAIN SERVICE PANEL 'M S P'-2 7 7/4 8 0-VOLT 3 P H, 4—WIRE INSTALL .NEW BREAKER IN EXISTING BUSSED SPACE. CD (" ----------------------------------------------------------------- ----------------------- ------------------------------------------------------ -------------------- ----------------------- rJ 1200-AMPERE FOUR WIRE BUS 2 REMOVE EXISTING CONDUIT AND FEEDERS. Lu ' ------------------------------------------------ ------------ - ---- - " ' '2; "3: 4' S 6" 3. CUT AND CAP EXISTING CONDUIT GOING TO 'OLD'BANK SPACE ABOVE C7 =V V • ,,` b'- " aa 62110 ' r��250/3 450/3 �i00/3 g 600/3 ; 400/3 NEW CEILING. W y Z Z I I 11 450/3 , , , I ' � ` ` 4. REMOVE EXISTING TIME CLOCK AND CONTACTOR. EXTEND EXISTING u Q —p 3 W ---GROUND BAR `'T ` 'r (2)3"C,W/ 4#350KCMIL m m= r r I (COPPER ONLY) FEEDER AS REQUIRED. i i I SYMBOL INDICATES MAXIMUM - I I ' SYMMETRICAL RMS FAULT AMP. ' ' ' 5. REMOVE EXISTING CONDUCTORS AND POWER AT 'OLD'COFFEE KIOSK. z (TYPICAL) i 335 Kw ca2o KVAJ,48o/277 v CUT CONDUIT THROUGH SLAB FLUSH WITH THE CONCRETE FLOOR REVISIONS u L-------------------------------------------------- -----'------- -----'- --------'---�--- --------'--------------------------------------------------' - ---r- , G 3 PH,4-WIRE GENERATOR AND GROUT SOLID. ' --(z)2'/2'C EA W/3#300 Al al SEE 3/102 ' ; J ,y--' 3/z'C w/3#Soo w----- o, 6 REMOVE EXISTING 450/3P BREAKER AND INSTALL NEW 600A/3P z , , ^ BREAKER. o , , 35000 U ai 0 Di (2)3'/2'C,EACH WITH 7 30 KW GENERATOR,X'FER SWITCH,AND FUSED DISCONNECT TO BE 1 oa a 1-J--TRANSFORMER '' r,TRANSFORMER \f./ 3� 4#350 KCMIL • 1#1 GND 1 y' n i i'_fff,''Ti' 300KVA lll 1'T2' 225KVA AG 4e04-120v/208v fff,480n-120Y/208V y, (COPPER ONLY) REMOVED BY OTHERS. `� 3 v I #i i' i ---(2)4"C EA W/4#750 Al (2)3'/2"C EA W/4#500 Al— __��__- - t (� 1 M q 8. PROVIDE NEW TVSS UNIT. SEE SPECIFICATIONS. U ' 2 31 I J 9 SEE 3/E302 FOR LOCATION 5300 - ' 24000 ' # M, ls000 'DP2'-120/208-V 3 PH,4-WIRE Ars 1 <P DPI'-120/208-V 3 PH,4-WIRE _____________________________________________________� 10. SEE 1/E301 FOR LOCATION. 1 1 --, 800-AMPERE FOUR WIRE BUS 600-AMPERE FOUR WIRE BUS 1016-- I . ---- ------- ------- ------- ------- ------- '-- -- '---------- ----L�% ' ,-- -- '--L-- ' I / ` F---r-------r::'----5::-----T:.-----T:.----r ., 1 I r ` 1 r-. r-, r., T., S -, Y ., q _ ... 1 z 3 a 5 6 - 11. REMOVE EXISTING 60/3P BREAKER AND INSTALL NEW 450/3P g l I l 5 1 I f 6 1 �: , I r 1 I I , I , 1 1 1 I r , I PANEL i PANEL , I PANEL , i 800/3 '�-' %•�-' %��-' '�-' 600/3 jy -%��-' .%��-' .''��-' .''��'' .!`00/ �-' BREAKER THAT WAS REMOVED BY NOTE 6 ABOVE. 'xb ' I I ' 100/3 ' 100/3 ' 150/3 150/3 ' 4'\ D4 ,. ., _ I , '125/3 ' 150/3 ' 225/3 ' T225/3 ' $25/3 ' 225/3 _____ , , i r 1 'M' I 'SB' 1 ' 'LP7 I , , , r r , r ' r , MINIMUM ' EXISTING UTILITY ' , , 1 , , , , , , , I ; i 14831 ---' 1 , , , , MINIMUM , L------ 37soo 9 12. GENERATOR PROVIDED BY OWNER. SEE SPECIFICATIONS FOR ,, X'FMR AND METER , 41743 L_ L__,__. ' "` ; "` T, "` "` SPACE O9 ADDITIONAL INFORMATION. "T \T `\T `` T T , T T T T T I M�_ t 32720 i i 2653z TAP GUTTER -- 13. INDICATED FAULT VALUE PER 12/30/97 AS-BUILTS. '°Y _ r----- -----------------' yam' IT-, 1 , i I I 1 2 ' 3 ��_ __'°m ro---•1"C W/3#4 Cu I I ' , 62110 14. GROUND AS REQUIRED. .--- ---------- ------------- _---________"' I ' I ' I 4 ' ' ' ' ' Zi a i i ''-TRANSFORMER 15. LOCATE TVSS UNIT AT TAP GUTTER. SEE SPECIFICATIONS FOR -'.-J -TRANSFORMER 3 i ' ' ' ' EXISTING PRIMARY I D-10 ;:-dk`'i�T4' iSKVA o' v, ' of o, I �' �' NI 1`fff:i48 120YAOBV 2 ADDITIONAL INFORMATION.3' 300 I i'fff:,480c�-120Y/208V �' ' 0 1 ' , tt l # Oc�- /2 D 03 ------------------' r_��_ #' , OI of , ----------------- , I ' a' \' #� ai 3i 3 i a, 24500 i �_ 9 9 16. 600A,480V,3-PHASE. SEE SPECIFICATIONS FOR ADDITIONAL 1 7759 i .J_ 3 i ' INFORMATION 1 3' 1 i 31 31 ' i \I \, VI 32120 e "}---1'/2'C W/4#2 Cu 9i 2"C W/ 3#4/0 I , , UI UI ' , 1'/2'C W/ AC-15 �' 1#a GND ' ' 17. EMERGENCY PUSH BUTTON TO ACTIVATE SHUNT-TRIP AT AC-10 iv I , i)l 1`71 : NI �+1 al ' \,-(2)3'/z'C EA W/4#500 Cu (2)2"C,EACH WIRE 3#1/0 Cu i 7 i (COPPER ONLY) i I i i i i 3#a/o'S 1#2 CND DISCONNECT AND SHUT-DOWN UPS. INTERLOCK WITH UPS AND (COPPER ONLY) SHUNT-TRIP AS REQUIRED. ' 1#6 GND r__L__ L__ ® ' ' r__L__ r__L__ ,__L__ r__L__I r__L__ ,__L__I , '• D-10 D-12 '-- '----- '--L-- '----- PANEL' i PANEL ' REF i PANEL i PANEL i PANEL 1 PANEL PANEL Q3 :COFFEE: 1 PANEL i PANEL i i PANEL i i'DP3'(FORMALLY RBD) -120/208-V 3 PH,4-WIRE 18. 75 KVA UPS AND ASSOCIATED ACCESSORIES PROVIDED BY OWNER 1 I , I I I __J______________________________________________ -ISOLATED SYSTEM KIOSK I _ AND INSTALLED AND,CONNECTED BY E.C. 'ECR'� GROUND i 'LP2' 1 M-4 i '8L' , '6L' , '7L' , i 'H' , 'K' , ,PANEL I , 'Ri' I , 'R2' d , 'D' ------ ------- ------- ------- - ' REQUIRED. L__-L. BAR L--__' __ __ __ _ _ - r., r-, r., r I 19. CONDUCTORS AS ____. AC-14 AC-10 _L. 24022 i 800/3 'r i : 'r 2: 'r 3: 'r 4: 'r 5' 1 {.l.j o0 I Cb\ 20. LESS THAN 10' 0". M t'/d,0 W/ FORMALLY 18660 FORMALLY I �-�$50/3 �-150/3 � %100/3 � ��125/3 250/3 i (T� �, PANEL 'CL' PANEL 'CF2' 1 ' ' ' O , )r•,,L� M n ._ n I L� `e 3#2 Cu i f\.—` w c0 1#8 GND FORMALLY 18000 V)O PANEL 'CFP 16170 1 ' ' ' ' ' TRANSFORMERS �- ----- --'-- A. X 75 14 SEE 2/E102 I I r r Q FOR ELEVATION , r r r U. D-13 ^ S M 1EM SYSTEM M SYS3 M-4M SYSTEM O m UPS 10030 O O O O 12080 N O � 1'/2"C W/ 4#2.1#6 GND 4# 2'/2"C W/ w N #40OKCMIL •1#1 GND(COPPER ONLY) 3#250KCMIL • 1#400KCMIL NEUTRAL uJ co TRANSFORMERS 2%2'C W/ 1%2'C W/ (COPPER ONLY) PANEL PANEL LPANEL O 1#4 GND (COPPER ONLY) �!V T4 ; 4#4/0 •i#4 GND 4#1/0 • 1#6 GND d `- = D-14 (COPPER ONLY) (COPPER ONLY) '1L' 'SL' L' U Z 21/2"C W/ 4#4/O 1#4 GND 10600 - - c 1"C co= (COPPER ONLY) 15000 211C W/ 4#6 1#10 GND e-G.. (COPPER ONLY) G (COP PANEL 3# • , NEUTRAL /1 /1 1#6 GND (COPPER ONLY) 'DC' 10030 ' lzoao SHEET LEGEND '-� LIGHT WEIGHT DASHED LINES INDICATE PANEL PANEL '--' EXISTING EQUIPMENT TO REMAIN. f• zL a1 O HEAVY WEIGHT SOLID LINES INDICATE NEW EQUIPMENT. �--( ---� HEAVY WEIGHT DASHED LINES r --' - INDICATE EQUIPMENT TO BE POWER RISER DIAGRAM REMOVED. E 102 NO SCALE W W O Q Z DISCONNECT SCHEDULE U z NO. AMPS FUSE TYPE VOLTAGE REMARKS ^r', i D1 600 LPS-RK-600SP 480 V NEMA,ENCLOSURE. DISCONNECTED TO BE SERVICE RATED ^ O W D2 600 LPS-RK-450SP 480 V NEMA 1ENCLOSURE PANEL LOAD SUMMARY W pG D3 60 LPS-RK-60SP 480 V NEMA 1ENCLOSURE LOAD CONNECTED DEMAND LARGEST TOTAL DRY-TYPE TRANSFORMER S C H E D U L E D4 60 NOTE 1 480 V NEMA 1ENCLOSURE RECEPTACLES 318364 164182 164182 IDS30 NON FUSED 208 V NEMA 3R ENCLOSURE LIGHTING 153024 38256 - 191280 W ( ) HVAC 560112 560112 560112 560112 CODE KVA PHASE VOLTAGE MOUNTING REMARKS /-d �r D6 60 NON FUSED 208 V NEMA 311 ENCLOSURE EQUIPMENT (NON CONT) 0 0 0 I� W D7 60 NON FUSED 480 V NEMA 3R ENCLOSURE EQUIPMENT (CONT) 37664 9416 47080 T4 75 3 SEE REMARKS FLOOR 480V-3 PH-TO 208/120V-3 PH,4-WIRE ~+ DID 200 FRS-R-150 480 V NEMA 3R ENCLOSURE MISC.(NON CONT.) 0 0 0 T5 75 3 SEE REMARKS FLOOR 208V-3 PH-TO-480V-3PH - D11 30 NON FUSED 480 V NEMA 3R ENCLOSURE OTHER TOTALS: 10775 6975 6975 969269 —- D12 100 NOTE 2 480 V NEMA 1ENCLOSURE MINIMUM SERVICE AMPACITY 0 480V 3-PH: 1166 O I D13 100 LPS-RK-t00SP 480 V NEMA 1ENCLOSURE D14 400 LPN-RK-225SP 208 V NEMA 1ENCLOSURE O NOTES: I. FUSE PER TVSS MFR.RECOMMENDATION 2. PROVIDE 100A HACR RATED BREAKER WITH SHUNT-TRIP. EXISTING SIEMENS Lo �` DISTRIBUTION BOARD 1 �. Q 00 Ui AR EXISTING SIEMENS 1 r. bra DISTRUSITION PANEL TJ4 d. �,; �r•ri " "+ a ,IS', 1'�n.q)sA.. REPLACE EXISTING + If p `I , r t -'� L I, THAT3FEDREAKE PANER'RDB' ty,* {':ad✓y� n• R% .1u I ' / IA44 a : _., `dl� & REPLACE . ,,` �' fir) ' de- k'- t. z u �'.,• NEW 600/3P 4.SSw9TE Fti% ' �1.t:.�1�'➢�{' �'`f. t„�'+M d p �? T• Y �r { Y 6 Yh"�� 4: I 4� H u N�: y� r: 885 pG (¢ Vol, !7 u3 f :i3' i- r 1k �jk .g, ..a REMOVE EXIS IN 60/3PEIRE ER AND - ALL 1 t ,w + .' �j4Yj• �{° u -" Y`• h ' �. REMOVED 450/3P CTA J05 NO. DELLCC j4 B "�' p rM EXISTIN 58 9 u' DRAWN CHECKED KERB SLW 2 # ,•+ DATE SHEET TITLE ` u ai s �, XISTIhG ^,PIN BREI�'EP i -. I ' tP s ELECTRICAL >,r POWER RISER DIACsR4I'1S 4 DETAILS 2 PANEL 'DPT ELEVATION 3 1 MSPI ELEVATION I lam/ +� E702 NO SCALE EiO2 NO SCALE L1r) DIES: PANEL'4L' u LLJ PANEL'IL' NOTES: PANEL'2L' PANEL'3L' NOTES: F.- <LU LLj 08V/120 VOLT,3-PHASE.4-WIRE t z 20BY/120 VOLT,3-PHASE,4-WIRE PROVIDE SUB4EED LUGS FOR FEED TO PANEL'2L' 2 SUB-FED FROM PANEL'IL' 208Y/120 VOLT,3-PHASE. 4-WIRE PROVIDE SUB-FEED LUGS FOR FEED TO PANEL'4L' 208Y/120 VOL 7,3-PHASE,4-WIRE FLUSH MOUNT(SEE I/E391 I SUB-FED FROM PANEL'3L' L) 400 ANF M1.0 SURFACE MUNI ISEE 4/E3021 400 AMP M1­O SURFACE MOUNT(SEE 4/E3021 400 AMP MLO FLUSH MOUNT(SEE 1/13011 400 AMP WILD ne 3:C5 k: u z CIT I LOAD KEYED REF LOAD BREAKER PHASE V BREAKER LOAD REF KEYEDI LOAD TIRE TXT S LOAD ION KEYED LOAD BREAKER PHA m�Lu NO NOTE DESCRIPTION SIZE NO NO WIREJ DE CRIPT NOTE NO VA P AMP A B C I AMP I P I VA NO NOTE DESCRIPTION SIZE NO NO SIZE DESCRIPTION NOTE NO VA P JAMPI A I B I C AMPI P I VA NO NOTE DESCRIP SIZE VA. CKT 5 NO E DESCRIPTION NOTE NO VA P AW A B I C� AW P I < ROW-511-CUBICLE POWER 10 2 -911-CUBICLE POWER 920-0� 20 1 960.0 BICUE POWER 10 2 I SPARE '1 20 71M.0 20 .1 TBO.O .1 ROW`-5A-CUBICLE POWER 8 2 1 101 ROW.-SA-CUBICLE POWER 1 960.0 1 20 1920.0 20 11'960.0 1 ROW-IIA-CUBICLE'POWER 10 2 1 1 8 1 ROW-113-CUBICLE POWER 1 480.0 1 A 1440.0 - I i2l ROW 2 3 SPARE 1 20 960.0 - 20 1 960.0 1 RON-SA-CUBICLE POWER 9 3 10 ROW-BA-CUBICLE POWER - 1 960.0 1 20, 1920.0 20 1 960.0 1 ROW­iIA-CUBICLE POWER TO 4 3 1 8 ROW-18-CUBICLE POWER 1 480.0 1 20 1440.0 20 11 960.0 1 ROW-58-,CUBICLE POWER 10 4. 3 12 ROW-98-CUBICLE POWER 1 960.0 11 20 1920.0 20 1 960.0 1 ROW-13B-CUBICLE POWER 10 4 1 5 B ROW-IA-CUBICLE POWER 1 480.0 1 20 1440.0 20 1 960.0 1 ROW-5A-CUBICLE POWER 8 6 5 10 ROW-8A-CUBICLE POWER 1 480.0 1 20 1440.0 20 1 960.0_ I ROW-IIA-CUBICLE POWER tO 6 5 8 ROW-18-CUBICLE POWER 1 480.0 1 20 -- 1440.0 20 1 960.0 1 ROW-58-CUBICLE POWER 10 6 5 12 ROW-IOB-CUBICLE POWER 1 480.0 1 20 960.0 20 1 480.0 1 ROW-I 38-CUBICLE POWER 10 6 Rr=vl low 7 8 ROW-IA-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.0 1 ROW-5A-CUBICLE POWER 6 8 1 10 ROW-IIA-CUBICLE POWER 1 960.0 1 20 1920.0 - 20 1 960.0- I ROW-11A-CUBICLE POWER 10 B 7 8 ROW-20-CMICLE POWER 1 960.0 1 20 1920.0 ' 20 1 960.0 1 ROW-511-CUBICLE POWER 10 8 7 12 ROW-108-CUBICLE POWER 1 960.0 1 20 1920.0 1 20 1 !60.0 1 1 ROW-138-CUBICLE POWER 10 1 8 9 8 ROW-IA-CUBICLE POWER 1 960.0 1 20 1440.0 20 1 480.0 1 ROMP-CUBICLE POWER B 10 9 10 ROW-8A-CUBICLE POWER 1 960.0 1 20 1440.0 20 1 400.0 1 ROW-IIA-CUBICLE POWER 10 10 9 8 ROW-28-CUBICLE POWER 1­960.0 1 20 1920.0 20 1 960.0 1 ROW-511-CUBICLE POWER 10 10 9 12 ROW-IOB-CUBICLE POWER 1 960.0 1 20- 1920.0 20 1 960.0 1 ROW-13B-CUBICLE POWER 10 '10 11 8 ROW-2A-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.0 t ROW-5A-CUBICLE POWER 0 12 11 TO ROW-8A-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.0 1 1 ROW-12A-CUBICLE POWER 10 12. 11 8 ROW-28-CUBICLE POWER 1 1 960.0 1 20 2340.0 20 1 1380.1 1 ROW-51)-CUBICLE POWER 10 12 11 12 ROW-IIB-CUBICLE POWER 1 960.0 1 20 2340.0 20 1 1380.1 1 ROW-13B-CUBICLE POWER 10 12 13 8 ROW-2A-CUBICLE POWER 1 1 480.0 1 20 1440.0 - 20 1 960.0 1 RaW­6A-CUBICLE POWER 10 14 13 TO ROW-SA-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.0 1 ROW-12A-CUBICLE POWER 10 14 13 8 ROW-28-CUBICLE POWER I ROW-68-CUBICLE POWER 10 14- 13 12 ROW­IIB-CUBICLE POWER 1 010 1 20 2.0 15 8 ROW-2A-CUBICLE POWER 1 960.0 1 20 1920.0 20 11 960.0 1 ROW-6A-CUBICLE POWER 10 16 15 10 ROWAA-CUBICLE POWER 1 960.0 1 20 1920.01 20 1 960.0 1 ROW-12A-CUBICLE POWER 10 16 15 a ROW-211-CUBICLE POWER 1 960.0 11 201 1440.0 20 1 1 480.0 1 ROW­6B-CUBICLE POWER io T6 75 712'HOPI-CUBICLE POWER 1 960.0 1 20_ 1920.0- 20 1 960.0 1 ROW-14B-CUBICLE POWER 10 16 17 0 ROW-2A-CUBICLE POWER 1 960.0 1 20 1920.0 20 11 960.01 1 ROW-6A-CUBICLE POWER 10 18 17 101 ROW-9A-CUBICLE POWER 1 960.0 1 20 - 1920.0 20 1 960.0 1 ROW-12A-CUBICLE POWER 10 18 17 0 1 ROW-28-CUBICLE POWER 1 960.0 1 201 1 1920.0 20 1 960.0 11 ROW-68-CUBICLE POWER 10 18 17 12,ROW-118-CUBICLE POWER 1 960.0 1 20__ 1920.0 20 1 960.0 1 ROW-14B-CUBICLE POWER 10 1 19 8 ROW-2A-CUBICLE POWER 1 480.0 1 20 1440.0 20 11 960.0 1 ROW-6A-CUBICLE POWER 10 20 19 tOl ROW-9A-CUBICLE POWER 1 960.0 t 20 1920.0 . 20 1 960.0 1 ROW-12A-CUBICLE POWER 10 20 19 B ROW-3B-CUBICLE POWER 1 960.0 1 2011920.0 20 11 960.0 1 ROW-M-CUBICLE POWER 10 120 19 121 ROW-118-CUBICLE POWER 1 1 1480.0 1 1 1 20 1440.0 20 1 960.0 1 ROW-14B-CUBICLE POWER 10 20 21 8 ROW-3A-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.0 1 ROW-SA-CUBICLE POWER 10 22 21 101 ROWAA-CUBICLE POWER 1 960.0 1 20 1920.0-A 1 960.0 1 ROW-13A-CUBICLE POWER 10 T2 21 8 RON-30-CLI81CLE POWER 1 960.0 1 20 1920.0 20 11 960.0 1 F&6B-CUBICLE POWER 10 22 21 12 ROW-129-CUBICLE POWER 1 480.0 1 201 1440.0 20 1 960.0 1 ROW-14B-CUBICLE POWER 10 22 23 8 ROW-3A-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.0 1 ROW-6A-CUBICLE POWER 10 24 23 10 ROW-9A-CUBICLE POWER 1 780.0 1 20 1740.0 20 1 960.0 1 ROW-13A-CUBICLE POWER 10 24 23 8 ROW-38-CUBICLE POWER 1 480.0 1 20 1440.0 20 11 960.0 1 ROW-68-CUBICLE POWER 10 24 23 12 ROW-0-CUBICLE POWER 1 960.0 1 20 1 1920.0 2D 1 960.0 1 1 ROW-14B-CUBICLE POWER 10 24 25 8 FMN-3A-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.0 1 ROW-TA-CUBICLE POWER 10 26 25 10 ROW-IOA-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.01 1 1 ROW-13A-CUBICLE POWER 10 26 25 8 RON-311-CUBICLE POWER 1 960.0 1 20 1920.0 . 20 11 960.0, 1 ROW-7B-CUBICLE POWER�2 T6 25 12 ROW-12B-CUBICLE POWER 1 960.0 1 2011920.0 1 20 1 960-01 1 ROW-158-CUBICLE POWER 10 1 26, 2T 8 ROW-3A-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.0 1 ROW-TA-CUBICLE POWER 10 28 27 10 ROW-IOA-CUBICLE POWER 1 960.0 1 1 1 20 1920.0 20 1 960.0 1 1 1 ROW-13A-CUBICLE POWER 10 28 21 8 ROW-3B-CUBICLE POWER 1 960.0 1 20 1920.0 20 11 960.0 1 1 ROW-TB-CUBICLE POWER 12 28 27 12 ROW-12B-CUBICLE POWER 1 960.0 1 20 1 1920.0 20 1 960.0 t ROW-156-CUBICLE POWER 10 28 29 8 ROW-3A-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.0 1 ROW-TA-CUBICLE POWER 10 30 29 10 ROW-IOA-CUBICLE POWER 1 480.0 1 1 1 20 1860.0 20 1 1380.1 1 ROW-13A-CUBICLE POWER 10 30 29 8 ROW­3B-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.0 1 ROW-TB-CUBICLE POWER 12 30 29 12 ROW-12B-CUBICLE POWER 1 960.0 1 20 1920.0 20_ 1 960.0 1 ROW-156-CUBICLE POWER 10 3D 1 960.0 1 20 1920.0 20 1 960.0 1 ROW-7A-CUBICLE POWER 10 32 31 10 ROW-IOA-CUBICLE POWER 1 960.0 20 T 31 8 ROW-4A-CUBICLE POWER 1 20 t920. 1 960.0 1 ROW-14A-CUBICLE POWER 10 32 31 8 ROW-48-CUBICLE POWER 1 480.0 1 20 1440.0 20 1 960.0 1 ROW­TB-CUBICLE POWER-F2 -2 TI 12'ROW-12B-CUBICLE POWER 1 960.0 1 20 t960.0 20 11 1000.. PLUG MOLD-TECH.LAB 12 32 I I I -F-T 440.0 20 1 480. -TEAM ROOM 9DO.0 1 20 1900.0 20 1 1000. PLUG MOLD-TECH.LAB 12 34 33 8 ROW-4A-CUBICLE POWER 1 960.0 1 20 1560.0 20 1 600.0 ROW-?A-CUBICLE POWER 0 4 T3 10 ROW-IDA-CUBICLE POWER 1 960.0 1 2DI 1440.0 20 1 480.0 1 POW-14A-CUBICLE POWER 10 34 33 8 ROW-48-CUBICLE POWER !.!2.;0: 20 1 0 1 ROW-TS-CUBICLE POWER 112 33 12 REC 35 6 ROIP-CUBICLE POWER 1920.0 20 1 960.0 1 1 ROW-7A-CUBICLE POWER 10 36 35 10 ROW-IOA-CUBICLE POWER 1 480.0 1 20 1440.0 20 1 960.0 1 ROW-10-CUBICLE POWER 10 36 35 6 ROW-4B-CUBICLE POWER 20 1440.0 20 1 400.0 1 ROW-88-CLIBI 35 -PHONE/FAX ROOM 1 360.0 1 26 1360.0 20 11 10000. PLUG MOLD-TECH.LAB 12 36 1 960.0 1 20 - --- I 37 0 ROWAA-CUBICLE POWER 1 1960.0 1 20 960.0 20 1 SPARE 38 371 SPARE 1 20 960.0 1 20 1 960.0 1 ROW-14A-CUBICLE POWER 10 38 1 ROW-48-CUBICLE POWER 1 960.0 1 20 1920.0 20 1 960.0 1 !Owj�-CUBICLE POWER 1 38 T7 �1!1!REEC-PHCNE/FAX ROOM 720.0 1 20 1020.0 ---- EFI-I Q 38 AA-CUBICLE POWER 1:01:9 1 20 960.0 20 1 SPARE 40 39 SPARE 1 22 960.0 1 20 1 1 960.0 1 ROW-14A-CUBICLE POWER 10 40 391 0 1 ROW-48-CUBICLE POWER 1 1 1960.0 1 1 20 1920.0_ 20 1 960.0 1 OW-8 -CUB ICLE POWER 112 4' 39 121 ELECTRIC DOOR STRIKES 1 1 20 680.0 v 180.0 RECEPTCLE-IDIF ROOM 12 40 GO 0 20 500.0 20 1 SPARE 41 SPARE -T1 $PAR[ 1 42 39 8 ROW I iol -20 1 SPARE 142 41 �42 41 1 SPARE 0.0 41 12 ELECTRIC DOOR STRIKES 42 ---i-- i 1 0.0 1 8 ROW-4B-CUBICI F POWER 1 1 1960 0 1 1 20 1 960.0 20 1 1 201 -J�2480 11�520 103201ALfS: 95 ONFUTER CENTER 10/30/01 DELL COMPUTER CENTER PANEL TOTALS. 10/30/01 ... PANEL 70TALS:1 12480 1 12000 1 1146CIAMPS: " 1.00 10/10/01 DELL COMPUTER CENTER PANEL TOTALS:1 12100 11700 1 D420JAMPS: 95 10/30/01 DELL CCWPUTER CENTER PANEL TOTALS: 10380 1061��11141-1-. 90 1 --------------------- -------------r----------------------------------------------- ---------------------r-------------r----------------------------------------------- ---------------------r-------------r----------------------------------------------- PANEL'5L' NOTES: PANEL'6L' :NDTES: PANEL'TL' :NOTES: PANEL'8L' :NOTES: 208Y/120 VOLT.3-PHASE.4-WIRE 20BY/120 VOLT.3-PHASE,4-WIRE iEXISTING SIEMENS PANEL BOARD. 208Y/120 VOLT,3-PHASE,4-WIRE EXISTING SIEMENS PANEL BOARD. 208Y/120 VOL I.3-PHASE,4-WIRE I EXISTING SIEMENS PANEL BOARD. 225 AMFI MLO FLUSH MOUNT(SEE I/E40111 250 AMP M1.0 :SURFACE MOUNT(SEE 3/002) 250 AMP 111.0 :SURFACE MOUNT(SEE 3/E3021 :225 AMP MLO SURFACE MOUNT(SEE 3/E3021 P---T TRT---- ---------I F r L---- ---------------------------------------- -L-QAD-T ---I PiT0E RiCE.L�AC jEF �E&, LOAD --------------------------------------------------------------- I 'KEYEDI-RCF T---T----p- 1CRIfA&------- ----rWTRP,&F' `CKT,WIRE, LOAD f1KENDT k4IRT BREAKER ---- r HA ,LOAD I REF KEYED, LOAD KEYED REF LOAD[LRE KER PHASE VA LOAD REF KEYED Log WIRE CK7 rdT rW FR P. ---coib-------rx-YE-Dr, REF LOAD LB�EAK L PAR VT CREAKY,!LOAD REF KEYED, LOAD WTRIF�56: rCErWFRC, LOAD LOAD LBREAKER L---,-�-r- IL: iSIZEi NO I NO SIZEi DESCRIPTION INDITE I NO 'F;,,iip I'-i-r- r IS IZE,NO CKT WIRE LOAD A I NO iSIZEi I NOTE I NO VA I 9AMP I A 14'�I VA I NO I NOTE I DESCRIPTICN I AP' I VA I NO I NOTE I ---DESCRIPTION 80 SIZE DESCRIPTION NOTE NO VA I P JAMP A 1 8 C AMPI P VA NO NOTE DESCRIPTION SIZE NO No ISIZEI DESCRIPTION I NOTE I NO VA Fr,jki I VA NO I NOTE I DESCRIPTION iSIZEi NO DESCRIPTION oi-f-UF - -p r,-r- ------I-f T--- r -1 -1 ...... rI2 -p ri�r-,i,,i&- 20 1 1200. 1 1 FIOW-13C-CUBICLE POWER 10 2 IC-CUBICLE POWER ----------------------------------- 3 1 12 ROW-9C-CUBICLE POWER 1 1200.0 1 20 240D.0 20,1920.0 1 1 1 1 1 1 -I ----- - IF_D CLE�CFWPEi rio Ii,,iC C(NF7EFFiCiIkM 1 0114 -' I I - I I ------------r T---:j6--T- 7---4 -9jo.j,--,-1,i iW fC-�6 FCL7E CR r1i,-i, 5-r jj --T---I---T j T 0.0 _IC------------T, .0 1 1, CLI81CLE POWER 13 1 9 .0 1 11 2C! 40.0' 1.3 1 20.0 1 11 20,1440.0 1 1 0 1 1,720.0, RECEPTACLES-M ... ----- ---F - ------------------T-fT------T-F------1-1--------- ----------------------------- 10 4 --------------------- ------I I I L-----I-------I I---------J--J--------------------- r------------------- - t4 1�: I,'��0.2L 1!3 J' 4 M P. I A' I R6�-ou' lb-'�12LML it A FLEqPT�C�E�.-�R�1.�I G 1 12 J' 4 12 ROW-9C-CUBICLE POWER 1 1200.0 1 20 1800.0 20 1 ,-1 -j- L-L PIP fO!7_1�1�k1PIE22'!!FL---- 10" 3 :.Mo-21 L 10,1 1 I�n __­L .0.1� I 1�: 0.2 IL 1 1�3 I C BIC E POWER To 1 4 1 3 1 1 L 600.0 1 ROW-13C-CUBICLE POWER 1,1 jeL ... . .....Ttt_SLL --- - ----------------L--I- L3-L 12�5-c 'L--- L 1 0.2 1 1 1, 1 1 1�6.01 20 1 11 T20.01 1 3 1 RECEPTACLES-TRAINING'12 1 61 5 12 ROW­9C-CUBICLE POWER 1 1200.0 1 20 2400.0 20 1 1200. 3C-CUBICLE POWER 10 6 1 5 1 101 ROW-IC-CUBICLE POWER 1 1!3 1, O.�I 1 1, 1 11 960.01 1 113 1 ROW-5c-CUBICLE POWER lio I IF: 5 .....F. ........ . I ROW-1 :2'2-2 1'�10' 1t4.01 201 11 480.01 1 1.3 1 ROW-91)-CUBICLE POWER 1 10 1 6 1 1 5 1 121 REC-ROOF -------- iC: 75.0 I 1 101 -E-1C--F-01----- 1 1.3 1960.0 1 It 200920.0 1 1 1 20 1 _f: -1-4�CO.OF At 1.3 1-----Fii-i CCE POWER 1 10 1 1 1 7 1 1 YAFFE I I I 1 1, 20, 720.0 IiCEFFTiCL7E!F RAIWR I ii 1 1200.0 1 20 2400.0 20 1 12W. I ROW-13C-CUBICLE POWER 10 8 7 12 ROW-IOC-CUBICLE POWER 1,9CO.�IF 1.3 1 FFOW:fC B iid i6ikl? �O'1 7 10,ROW-20-CUBICLE POWEPF 1 1.3 1 060.0 1 le 200440.0, 1 1 20 1 It f P--1 Op,i&- ------------r -r---I---T-riT---I-I f2C ---- -- -----ii4- -------- -CF, F r i;iE7C- -------r-i,T---:iCFo.i T-,r-2�--- i6-,,- jio.-O I- i*------E E T C E :R IWj' I --jo-, ---I- ----- Fc I I - �j L jE_ ------ ---5 r _21F e _�UOCLCED; IC2DT fi, ti�, i I I 96.Or 1,3, F I OPP ROP-CUBICLE POWER 15 T 9C05 I'W, Ii2lFg 2e. 965 1.3 6PFC- B E POWER 1 10 110, -CUBICLE POWER 13 1 1960.0 1 1 111 1 111 ICLE POWER,10 1 9 t 12'ROW-IOC-CUBICLE POWER 1 1200.0 1 20 2400.0 20 1 1200. 1 ROW-f3C-CUBICLE POWER 10 10 1 1 1 1 1 1 - �i r-I il.jCC:jUDOLLCWM-------r-f T -Pjjo-oT-1 r ig--- ---1-------------------r- ------------1.-1 j T -,jCo j T-11--2j---7---T 1.-3-1----------------r--i-i'l r 7,1,-1(p.i(Fw 3,F-6f CF;kFi�----r T---I�0.-0 T-1 f T 7---7--- -IT -&CR 1'8 12 �,T, 7io ir, AIMING 12 j 12 3C-CUBICLE POWER 10 12 ri f 10.ii-W--CUBICLE POWER 0.i�, 9co o 1-3 i6i--16-�,iFc ---- I-L-I--- -1 1 L- J J1.....RECEPTACLES L 1 1200.0 1 20. 2580.0 20 1 1380. 1 ROW-1 U-D-J L J J------------4E I L-J--1 L L J------------ I 2(TI 11 12 RCN-IOC-CUBICLE POWER I L-L-J----------------L-'-L--- I L ...I u j j FIOt C BL E POWER 0 j L-L-J----------------L -I---I-L-01 1 A it4CL L L ------------- 4 1 1, (�EPT�CL.E�.- RAIN NG Iq tC-�UBICLE POWER 110 114 1 1 123 F 10,'Nw-2EL-AELI CLL� 1 1�3 1, 0.2�'I t­10�1 19L0.2�I I I 1�: 11 2�0.�1, 11�3 1 -IT:�M�CLE fq!�R IZO 1� _2 1 �E 121 ROWAOC-CUBICLE POWER 1 1200.0 1 20 2400.0 20 1 1200. 1 ROW-14C-CUBICLE POWER 10 14 I�T3 1,1�1 I Iq O.��' 11,20,1�9 O.� I ... ...... _11 960.0 L12 R Lo 13 4--- 1 1 20, 3 RECEPTACLE-ROW 1 12 1 fl� 10 1 15, 10,RON-2C-CUBICLE POWER 1 1.3 1 1960.0 1 It 20H 1 1 20. 1 1 1 1 9 t I I - ------IF -if: 1 15 1 10 1 ROW-30-CLIO ICILE POWEFF 1 1,3 j96O.O I It 20t 1 1920.01 It 960.0 1 1 1.3 1 ROIFIOD-CUB ICLE POWER I ....... 1 20, 8 1 If, 1 15, 'SPARE 1 1 360.0 1 1 20 1 It 360.0 o I I------- -iW WIG - cn co RCC /fRiliNF1 '02 If: co 15 12 ROW-IIC-CUBICLE POWER 1 1200.0 11 20 2400.0 20( 1 1200. 1 ROW-14C-CUBICLE POWER 10 16 15 --------- 1.3 IfWe,W: 36.0`7 01. D;EF :ico.i 1 11 1 1 1 1 3' 96.0 IF 2e, Ifi e,Y: 96.i 1.31 --16 CIIE P66 1 8 If: IT F iP,�LFBF47E P R ------ - -- ----- F�7 F ie,ii--46-CUBICL I I i2 I W: MAP— 1.31 C-�LiFCIi�(FW6 NO I Ip. Ff? le,ii--2C7--C7UEF1CLCF70W 15 0.0 IF 2e, I 17 12 ROW-11C-CUBICLE POWER 11 20 2400.0 20 1 1200, 1 ROW-14C-CUBICLE POWER 10 111 1 1 1 1 1 1 1 1 1 .-r- T r---I-9jo.j T-,r ii�-9�0-0 1---'I---'I j�,-,I-9jo j r---1-1-3-1-------------T�WCR r i r,i r j,-1-----FWEj---------T-1'1 T---j Co.j T-11 1200.0 P­,�,r-1 WV_y-iW ----r-,j T---I jCo.j T-11-2dr '.j'r---7 7-2�1 1-1-9 Co-0 r -i-I---------------- -- r .1 !C!j1�D:SLLQ�E �I . 'I i(FI-11-7jo-0 r---1 '1----------------r--,iC, _ I CL f�O PF fi� .19jo I, r 19 IDJ M7' --C�U�I I---FL----L J. I-L-I- 1---L---.1 J--'-L--J-�'J- L J_ L-L-2j�UBLM 5L----------L- L------I L I--- J I-'.!L--J J I-------- J- 19 12 ROW-11C-CUBICLE POWER 1 1200.0 11 20 2400.0 - 20 1 1200. 1 ROW-14C-CUBICLE POWER 10 20 -------I--------L-- L-I- I- I I--1-1--*-L J--J----- LT J�u-; L-L- -IL 1 1, 1 1]1 O-�P­ I OL- __fE�C:��/TRAINING'12 '221 21 12 ROP-CUBICLE POWER 1 1200.0 11 20 2400.0 20 1 1200. 1 ROW-14C-CUBICLE POWER 10 22 L22 1,10,'Mwl�--TELIcLLELTWER 1 1�3 1.2 1 1,11�1 I I 0�1 I 1�: 1�1 2�0.�P� 113 1 FTti� �ILB LCLE POWER 1 10 22 1 211,10,1!CLI-4 -_�U ............. j! !�k CL M.2 1, 11�3 1 1�D:PLB LQ�E POWER 1 8 122 1 1 211 1 I 1,10,' 1 -O�' L-1- AIIE 11, 0 ...­, IL:_ ;L I - 23 12 ROW-IIC-CUBICLE POWER 1 1200.0 11 20 ....... ----4 L- j 8 1 1 11 201 1 720.01 20 1 It T20.01 1 3 1 REC-CONFIiiiIiIiIiIi'12 0 1 12 1 ROW-14C-CUBICLE POWER 10 24 1 23- 10 1 ROW-3C-CUB I CLE POWER 1 IJ 1 1480.0 1 11 20, 1 1 1440.01 20, 11 960.01 1 1.3 1 ROW-6C-CUBICLE POWER 1 4 1 1 23 1 10 1 ROW-5D-CUBICLE POWER 1 1.3 1 1960.0 1 11 20, 1 1 1920.01 20, 11 960.01 1 1.3 1 ROIF12D-CUBICLE POWER I 1 1 23, SPARE ------------ --------- -- + ------------ F F -I--- --I-i-I------iCC IfRil 2 if: -----------I- I-- - - - I- I ic:-I- -CUBICLE POWER 1 1,3 1 1 0.0 1 1 01 1 1 1 It I I I "i I - --I i1f: It 75.01' 1 1 ,r,--,if, 9c 101,ii-iC - C' I f5i I iF�AIFE I 1 01 1 1 1 ------ I 3 T---:-gCo.j T r ie T j - j& f, ri7 r--,iFF -------- PoLiS 2 21, -10.WN qCo.j T-11 j� 'T- r 0 1 1 31 --1 fD CITBF E�WR IMF iCF'- 11 0 1 FW-fC CL7E�WR'1 8 1 ii io- I- ----W -- WE7 i-,"j -----------r--T--- T-jr j(�---7-75 0 1'TiO Or POWER 20 1 ROW-15C-CUBICLE POWER 8 26 1 1 Ww-V-CUBICLE POWER 15 1 O.i 0 .0' 1.3 F71iD C(TBFCL7E W R 8 1 i 7fo.i 25 12 RON-11C-CUBICLE POWER 1 1200.0 11 20 2400.0 1200. 1 :9c it iol iiio.� 1 1,3 9CO I 2 N95.�_jC-C Iwic ic FL7 POWER 6 2i, "f7r' cc _ UEFICLE-ik-----r T--- Ij4(Tj--- _ : B C E 10 ROW-12C-CUBICLE POWER 1 1 1200.0 11 20 2400.0 20 1 1200. 1 PON-15C-CUBICLE POWER 8 28 R 113 . . 2�1 4fo 01 1 3 L I L i----------------L L------ -------- --27 L--1----------------L--L--- L j--'.!L J-!�j------------- L L-- --------------- ---I-- ---.L - -------- ------- 29, ICL: 1 8 130 1 29' 10' CL .0, 1,1 291 101 ROW-12C-CUBICLE POWER 1 1200.0 1 1 20 1800.0 20 1 600.0 1 ROW-15C-CUBICLE POWER 8 30 'L2�9 1,10,1 ROW C I�LE�TtER 192. 20 1 960 0 113 -7 - --1 -3 -1 L 1011---4, 1 1�2.10�1 ICL: 1�1 1�0.2 1, 1 1�3 -I�D �JLLBLCL�E POWER 8 130, _�2 R POLES 12 1301 ----3 - *� j--I----- ---------- ... . .... ..........fl!E_ I i!-3 I.M.2 I --- --- 3 31 101 ROW-12C-CUBICLE POWER 1 1 113 1 1480.0 1 11 2011440.0 1 1 1 20 1 11 960.01 1 113 1 ROW-7C-CUBICLE POWER 1 32 1 311 10 1 RCIP-CUBICLE PO R 1 1�3 1. .0 1 11 2011920.0 1 1 1 201 11 SSO.01 1.3 1 ROW-131)-CUBICLE POWER 8 132 1 11 T20.0 1 1 4 1 P ER P LES 12 600.0 1 1 20 1800.0 1 L..... �Lo - -----------�w 0 .....F.. + 4 'C - 33 It I 1 720,01 1 20 1 It 720.01 PKR POL S'112 i 20 1 1200. 1 ROW-15C-CUBICLE POWER 8 1 32 1 311 10 1 ROWAC-CLIBI LE POWER ........... -- ---------------- 10 ROW-12C-CUBICLE PIT ER - ---------- -fC 1 311 ROW-13D-CUBICLE POWER 1 8 04 1 1 iSPACE - I------I I ROW-60-CUBICLE POWER 1 1.3 1 1960.0 1 1 201 It 4 0.0 1 1 12 2400.0 20 1 1200. 1 ROW-ISC-CUBICLE POWER 8 34 1 1 I I 1 201 1 1920.01 1 111 It 960.0. 1 1.3 1 ROPPI-TC-CUBICLE POWER I 33 1611 ii�C-CUBICLE POWER 1 1.3' O.OT 6 ii, �i3 I 01 1 1440.01 - - -C -- T-- I r-2�-------- I --�WR r if, rf,r --r- T--- T r T--- r i ---------------YCE r if, 8 36 W15 B-,i6 rf,r j(p,jj U�j CLCFojFF 1.31 9 O.j T 10 ROW-12C-CUBICLE POWER i,r-,6,,ii�i,-CU-CLCF;k�----r T---I---0 T r-2dr--- 7-Ij2P�e -0- Ij ROW-7C-CUBICLE '�D:.9�LC'l --L j . I 2�: 9 Co. TS -1 2 :0 2400.0 20 1 1200. 1 ROW-15C- --- CUBICLE POWER --I--T-L - I---L----1 L---,1111. 1 1 1 1 1 1 1 1 1--T I-----I-------- I-L------1-L-I----1 -- L T7 10 ROW-12C-CUBICLE POWER I IICLE POWER 1 1.3 1 1 ER 8 138, 37' 10,'ROW-70-_CUBICLE POWER 1.3 1 '960.0 1 120'1920.0 20 1 V 960.0' 1.3 ROW-14D-CUBICLE POWER 1 8 38 37 Ll I 2400.0 20 1 120D. ROW-16C-CUBICLE POWER 8 38 ---:960.0 1' 20'1920.0 20 1 1'960.0' 1 1,3 1 ROW-8C:C ICLE PON L L-L ---- - -I- L- SPACE L----------------------��A(LE L 'LILT 1,10,'Mw��.-AEL I L--L---- L-I- - -I!B----- - - - --I--- 1'L I I I ISL 1 101 1 1 -8C-CUBICLE POWER 1 8 140 1 1 391 -70-_C� q 1. .1 1 F101 1 1 jl�.: 1'480.01 IJ 1 ROW-14D-CUBICLE POWER 1 8-1!0 1 39, 1 SPACE F I 1 .1 1 0 T9 SPARE 0 1200.0 20 1 1200. 1 ROW-16C-CUBICLE POWER 8 40 1 391 101 ROW-4C-CUBICLE POWER 1 113 1 1960.0 1 11 201_ 2CLOI 11 S60-01 ROW 101 ROW UELIC�LELF�GVP�R .... :21�0 ............ ......:_it ............. A E 40 -------------------I---+-IF-. 4 - + ------iCCCP5CL6�5 4f: SPACE T, SPARE 1 20 j200.01 20 1.1200. 1 ROW-ISC-CUBICLE POWER 8 42 �i.L 10,ROWAC-CUBICLE POWER 1.3 960.0 1 It 20. 1 1 1920.0,20 1=1 1 960.0, 1 1.3 1 ROW-8C-CUBICLE POWER 8 42, 1 41, 12,ELECTRIC DOOR STRIKES 3 .500.0 1, 20, 11040.0,20 1 1,540.0 1 13 MISC. ��I jFPAE -------- t0.0 11....... Lu DELL COMPUTER CENTER PANEL TOTALS:1 16200 1 15OW 151601AWS: 129 10/30/01 DELL COMPUTER CENTER PANEL TOTAL$: 12960 12960 13380�AMIPS: 109 10/30101 DELL COMPUTER CENTER PANEL TOTALSt 12480 12000 11600:AMPS: 100 10/30/01 DELL COMPUTER CENTER PANEL TOTAL$:1 6000 1 5400 5280:AMPS: 46 10/30/01 1 LU z Lo 0 NOTES: :NOTES: PANEL'0' :NOTE$i PANEL'DC' PANEL'ECR' PANEL'H' :NOTES: 20SY/120 VOLT,3-PHASE,4-WIRE SURFACE MOUNT 20BY/120 VOLT,3-PRASE.4-WIRE I FLUSH MOUNT EXISTING SIEMENS PANEL BOARD 208Y/120 VOLT,3-PHASE.4-WIRE :FLUSH MOUNT(SEE I/E301 EXISTING SIEMENS PANEL BOARD PROVIDE ISOLATED GROUND BUS. 208Y/120 VOLT,3-PHASE,4-WIRE I SURFACE MUNI(SEE I/E3021 EXISTING SIEMENS PANEL BOARD 1 :225 AW 111.0 :50 AMP MAIN CIRCUIT BREAKER I ----------------------------------------- :400 AMP WILD 225 AMFI M.L.O. ----------1 -----------r RCF-�-L-CA-D T 86411' 'TORCAEFF.'WffggffR ---7C 191jr r - r -:-L-- kWil T "FRCACEFP. r i' 'C0T,rWFR0, LA T 'KEyEDT ----------- -------:F ---------------r 11W I-------1w, CKT I LOAD KEYED REF LOAD BREAKER PHASE VA IBREAKERI LOAD REF KEYED LOAD RE CKT LOAD RCF GAD T VA j LOAD, REF KEYED, LOAD j LOAD REF KEYED, L WT W r- r-C-I&,,� r--- .0 SIRE A B C AMP I P I VA NO NOTE VA --- ---------------A-r-ZE DESCRIPTION NOTE ND VA P E NO I NO iSIZEi DESCRIPTION I NOTE NO I NOTE I DESCH W REjAAK L u L i ,U IS I NOTE: NO VA I NO I NOTE I DESCRIPTION iSIZEj NO VVA r- A DESEGURRIONON MWEi NO DESCRIPTION S ri�r--I I NO I VA PTI ON IZEi NO I NO iSIZEe DESCRIPTION A B C 1AMP P I ri�r i I WCCpj7ACLf----------T T Ifo I mi%M DOGGRIRPTOON I NOTE I NO) 4_E� AMID, P I V I MOO iNIOTE i --T--- T iir-C ------- ri�r --P-j T--- 3, Si F�L�2 j �40.0 11 1 20 t540.0 1 1 -5 1 1 1 1 An 2 1 12 TWIST LOCK RECEPTACLES 96 DUPLEX RECEPTACLES-19'RACKS 12 2 1 1 1 1 .6 Siii r E n , I I f2fo.j --------------- 0.0 11 20 1920.0 1 120 1 1 960.0 - - ------ I I I I 1 1 1�2 1 1 R: I ...... E 7 1�.�AILE��R LI2 J' - I .DIL IL I G., I 1 1 ------ SPARE 1 14 1 3 12 TWIST LOCK RECEPTACLES 960.0 0 1 201 11 SPARE L' �60.0 I I 1 20 '360 0 ....... 1 20 1920.0 0 1 DUPLEX RECEPT -19'RACKS 12 4 1 2 --------- J' L�.L 10J' ------------- 960.0 . ...... . L1L L !E�CE�P�Aq�---------- ---L ACLES 3 E------------- A-1 -1---L J J------- -19'RACK I I 11 2�1 1 1 0.0 1 201 11 1 1 1 SPARE 1 6 ',�L F10 1 AC-T I I 1 1 20 1 11 960.01 1 3 1 RECEPTACLE-ROOF�II2 6 16 5 12 TWIST LOCK RECEPTACLES 960.0 1 20 1 960.0 DUPLEX RECEPTACLES E ........... ............. ......... 4 1 If 1920.0 20 1 -f ------ F !ELCE�PTACLLE� I S 12 6 I'L --------- 4--I- I It I TIC 1 12 i-f� 560'0 il 120 1 1 1360'0 1--11 1 1 1 1 -SP-AFE E 7 6 ic-f .......... I -+-F-4---4---4---4 -4-------4---1------------- DUPLEX RECEPTACLES-19'RACKS 12 8 If,- 1 2 1 14504.0, 31 5014T64.0 I 7 1 E I RECEPTACLE 1 1 560.0 1 1 20 1360.0 1 1 160 50 1 1 1 1 SPARE I 18 1 12 TWIST LOCK RECEPTACLES 960.0 1 20 1920.0 20 1 160.0 7 SPARE I I I 1 201 0.0 1 1 1 201 It I I I - slicc----------- f-------iE RIF EFRCACF06M'12 IC: ------ r-------------------!Fp iC 7 IICBIF� ....... 16.0- rf r-n----------------r r---I- T-1 r ii� -r- FFOi IIF E T�CL7E- �f r i -R��pfACLf-----------I rfo CFi i I Z-C Z.1 1 110, 1 1 ARE 9 12 TWIST LOCK RECEPTACLES 960.0 1 20 1920.0 20 1 960.0 DUPLEX RECEPTACLES-23'RACKS 12 10 1 SPARE I I I I I - r -8 -------------r T---:-4!FgF -- 12 T2 ri�,r--1 YIF-------------T T- T iCFF r i, BREAK ROOM 1 12 '12 ri�,r -1-HOWjCNj---------- 960.0 1 20 1920.0 20 1 960.0 DUPLEX RECEPTACLES-23'RACKS 18(Te Y' I"IZ-O EETTCE-iIIWT i Z. E I I VENDING T�rf,T---T--- -------------�p--r--2 1 2J ----------------L-J--1 --- J---L ------- REL L J� 11 12.TWIST LOCK RECEPTACLES ------L L--- -1-.1---L -1 J----------------L-J--1 L ------- FI�I(E T2 14 11 1 13 _�4 12 TWIST LOCK RECEPTACLES ;1�2 960.0 1 2011680.0 ECEPTACLES 12 14 1�3 1, A�E............. I to.� 1�1 I tO.2 Eq�TILC E:IFLONT MEZZ. E 4 1 _2L 1 20 1 720.0 GENERAL ROOM R ........ ... _4_ �O __­,_�41......... �FL -------------- -L3 1 201 It 360.01 1 1 ON,wzi. 1 11� 1 51 10,AC-11 S-BREAK ROOM'12 If: 46 115 12 TWIST LOCK RECEPTACLES 960.0 1 22 1320.0 20 1 360.0 RECEPTACLE-IDF ROOM RACKS 10 16 1 151 1 SPARE 11 20, 1 360.0 1 RECEPTACLE-F 1 2 1 2220.111 1 1 1 2720.01 201 it 500.01 1 3 1 REC-COUNTER TOP -"15 -:iW .......I 2i2l�e,i(r, 0.0' RiC-��TEiR T AIF OCM'2 If: ------- 1 1320.01 201 1 360.01 1 RE ----------CEFLWF7 AiS I IV' -------T r-2� --- 4ii I 5 AR SPARE ECEFrTACCE FfO�7 WZi. E If: Ii7 I DIP iC-�I IF 2e,---- CUP il�: 36.0' 1 288.0 1 1288.0 1 1 1 0 1 SPARE I ----------------- I-P-c -.11-8 11 12 TWIST LOCK RECEPTACLES 960.0 1 20 CEPTACLE-]OF ROOM RACKS 10 18 Ili PIT, E SUPPLYFAN -------- -4fl I fo-0-1------- -f,jr- -1 -1----nFiEiTiCt7E-- F�O�T k-Z-r- r i r-I jFW-------------T 7 r i r,-E-,j)F";UfT-F TN----------T T---r�f,,F Tf ri-,Tfif .7 19 12 TWIST L RECEPTACLES 960.0 1 20 1320.0 360.0 RECEPTACLE-]OF ROOM RACKS 0 0 r,i r SiA E j- r 20-1 1 L j---------- -'R I J------I--------�'L ----- L J----------------L-�ELE'!�ME:!not'!�PL 11 432L L I AILE------------ ----------jXN .�U�T IAN E -22 1 ------ 11- I---IL -11 -it--------------I-L w !)!AUST F RECEPTACLE-IDF ROOM RACKS 10 22 L22 ?A�E------------- 0.2 AI 1 11 201 1 1 180.01 20, 11 180.0 1 1 1 RECEPTACLE-FRONT MEZZ.I E 124 1 1 23, 1 SPARE 1 11 20, 1 1 900.01 20, 11 900.01 RECEPTACLES-BREAK 1156i�12 -i4 T3 12 TWIST LOOK RECEPTACLES 960.0 1 20 1320.0 20 1 360.0 RECEPTACLE-IDF ROOM RACKS 10 24 123 1 1 SPARE ---- .......... 0 I!L L2L 4---4 52A 4---4- ............!LPARE P.2 21 12 TWIST LOCK RECEPTACLES 960.0 1 20 1320.0 20 1 360.0 1 23, E I EXHAUST FAN 552.0 1 552.0 1 1 1 1 1 SPW--1 - ---- 3c ------t T-------T 5 0.0' 2e RECEPTACLE FRONT E if: IF 29 5iO.i 11 I iio I f F-5 I liNiT f----- I I 60.i+1 T I'io+fcw.6''1 13 1 1 1 1 ARE 1 25 12 TWIST LOCK RECEPTACLES 960.0 1 20 1320.0 20 1 360.0 RECEPTACLE-IDF ROOM RACKS LO 05 T---I---T-r-T---I j jil- NFC-E�-Ti-iC-E r-E -i r- T---F6Z6*Tj-lio I--- 26 1 251 1 RECEPTACLE-FRONT MEZZANINE 0.0 1 1 1 1 1 11 SPARE I I I I To r r ---T---I-3CO-0 T r ij----Vo-0------2C,-1,-If-0 r---------C p : E-Aai- r--1 ri,r iii ---------- SPARE fT I --'--Cpj7 - "T-ME T RCI517 F71FF CCN IS71NO LOAD 1 1 S .0 1 2 7 1"-1 io-0 E FiC ACiFF W I - 271 121 TWIST LOCK RECEPIA 1960.0 1 11 20 960.0 20 1 -1 J I=IL- i---------I----TRILL L 1 j 1U T iii POLES -- -- --- I L - 9 IL YLIT T�R Lu 960.0 20 1 SPARE 30 L -:!to-!1 1 L M I---I--- L2L _tEJL ...... ..........!�CELP�A(�L�S�' 2 CLES _L9 12 TWIST LOCK RECEPTACLES 960.0 11 20. 1 13� 1840.0 1 11 2011$40.01 1 10 1 it 1000.0 1 3 1 Lu 1 1 12 1 60 1 0.0 1 1 150 13 1 1 1 1 SPARE 1 52 131 12 TWIST[OCK RECEPTACLES 960.0 1 20 960.0 20 11 SPARE 32 1 fI I E I RECEPTACLE FRONT MEZZANINE 1 1 1360.0 1 11 201 360.0 1 1 201 11...F 2 311 E I LIMIT HEATER--- REC-COPY/FAX 1 12 '321 FRONT MEZZANINE 1 1 1360.0 1 It 201 1 360.0 1 1 20 1 It I I I 1 64 33 12 TWIST LOCK RECEPTACLES 960.0 1 20 960.0 SPARE 34 180.0 1 It 201 1 680.0 1 1 2CF1 Is 56.01 1 1 REC I ------- -- -------------- + + I- + 4 4 ........ 3 ------ ---------- -C­WY7Fi Fi2 3i: F + 20 1 1 33s E I RECEPTACLE f3 i iRCPfA R! I j.-CCp�ACLC----------T r---:-36 jT-r i6r--- r---1---i----------------r �-36 I ------r- T---I T r T---7 I -------- -1-7---r---I--i-------------�PTC r- 36 'f5'i' E EXHAUST FAR- r-2 if, 331 1 SPARE e,2DT: 2i.,r z I rf 75 TWIST LDP RECEPTACLES 960.0 1 20 960.0 20 1 SPARE I------I---I I I I I j r SiA E T __L2 ---- -- -- ---- - r T I 1 j---L j j-------------I--L.----I I r 0 0 -- 20 1 SPARE 38 37 1 E I RECEPTACLE '360.0 1' 20' 360.0 1 1 20 1 IL ---1---- 1 960.0 i -------------------- _Ll 2 TWIST LOCK RECEPTACLES 960.0 1 20 1. .1 F1 140, LL 1 --- 1�0 ---IL _L SPARE 40 11�9 - 0 1 .................. ­ LiLT L ��mE------------- :- 1 960.0 1 20 20 1 ' 1 11 1 1 'I" W,I,IL9 1, KAI�E SPARE 40 1 _L9 2 TWIST LOCK RECEPTACLES 960.0 ......:___ -4--- ----------------- ------ ------:- .............. ...... I--------------------F--- _L - .... I I I It 201 o'I 11 1 1 1 41, 1 1 It 201 1 1 0.0 1 1 4 1 1 20 1 0.0 1 2 41 SPARE It I SPARE --------- - ---1 411 SPARE I 1 20 1 0.0 42 DELL COMPUTER CENTER PINIPMELTMUS: 2740 2244 1320 IMIPS: 17 10/30 01 1 DELL COMPUTER CENTER PANE 77 DELL COMPUTER CENTER PANEL TOTALS: 1626 1 1620 1 1440'AMPS: 13 io/30/01 DELL COMPUTER CENTER PANEL TOTALS:1 12540 1 12110 1 13144:AMPS: 107 10/30/01 0 Lu /------ --- LQ 0� -----------------------------------r----------------------------------------------- ---------------------r-------------r--------------- : PANEL'LPI' :NOTES: PANEL'LP2' :NOTES: PANEL'Ie NOTES- PANEL'K' :NOTES: I 208Y/120 VOLT,3-PHASE,4-WIRE :FLUSH MOUNT[SEE I/E301) EXISTING SIEMENS PANEL BOARD 4BOY/277 VOLT,3-PHASE.4-WIRE SURFACE MOUNT ISEE 2/E302)EXISTING SIEMENS PANEL BOARD 480Y/277 VOLT.3-PHASE,4-WIRE SURFACE MOUNT(SEE I/E3021 EXISTING SIEMENS PANEL BOARD 480Y/277 VOI.T.3-PRASE,4-WIRE iSURFACE MOUNT(SEE 2/E3021 EXISTING SIEMENS PANEL BOARD :225 AMP MLO :225 AMP EEO :100 AMP MILO '400 AMP RED - ----- I ------- --------------- --------------- I---To r j TB�E�XfRT------ -------r Ri&' PWA§t-W----BREAKER LOAD REF KEYED, LOAD WTRPI51KT' T T -PH-AfE W--- WTRE:&T' `CU5FRO, LOAD 'KEYEDT REF LOAD -------r ======r==T=== -1---T---T-- V-i--L r---r---- -------COTD jVTRPi5KT' T,'1FRF, LOAD I I u L SIR SIRE: LOAD LOAD LBREAKER j LOAD REF KEYED U L -------- 6A 96KIR PWE V� WEE LW REF EiE�, IKEYED REF L& PHASE VA �BREAKER,LOAD REF KEYED, LOAD :1 F,-A%Fp, -�. VA NO I NOTE i DESCRIPTION iSIZEi NO KT,WFR�I-------COZ KNID'RI5F I EE:CKT: :CKT:l L L: r---u j VA NO :NOTE DESCRIPTION SIZE,NO I NO ISIZEI DESCRIPTION I NOTE NO P AMP, A C I AMP P I VA O� V ---1!- j I I NOTE ppFp, -Z-r-F-r-C-141"PI VA I NO NOTE. DES TION DESCRIPTION E: No I NO iSIZEi DESCRIPTION I 21� !A- ..... CHIP NO, NO ZE I :-jj-of6Ti�`Tj I NOTE I NO I A I P AMPI A 8 C tAMP P I -.1---1- I f4C7fol---4 '1 -1 610- , NO I NOTE I DESCRIPTION SIZEt NO --- r ri�r ;;;RCHI 16 i FGN�T�------I r --4---7 r -1---1-----------FECiFFT--r--1- r,- -foi,1-6------- r focf I ---7 V!-F,�f2i� ----------------------r--i-ij r- fof- 20, 720.0 1 L j-21 - I - - - VA I NO SIZEi DESCRIPTION I ---:4f2i.07, 2, 20,8642.0 1 f PARKINGLOTI..1 GHTS E y r i i-RECCpfACLC---------- '360.0 1 1, ACLE, , i, T I 2299.If, 1. 2(7,fgig.o 20, ------ I-- I------- AC-I ------------- -----I I I --------- r T ---------------------7 T-- 1101 _4 c , , 3�,t I I _4 ARy�jq I LaLT!L.............4�21�.O' L !(L4�..O'L 4� An N�. S I I - 4PIR:0,---I - L L ---------- ---I--- IL io.11 I itm ii�.: I,'2,iLm L ---------------ILEqF�T�E 4 L�L -P .............t KL LO��ITIL _j I u L3 'L --------I-- :It3t-O.1 L 101L n(Llit--- _1,1 j� ................ L3 L! !�.�------------- it 360 t I 1 5-I E LIGHTS-RON 14 124113.01 It 2�1 1 jL6i�O'20 1 11 1773.t I VALENCE LIGHTS' E 6 1 5 E I PARK ING LOT LIGHTS 2 F1!�11 21 3601.0 1 1 PARK ING LOY LIGHTS E 1 61 1 5 1 E I AC-I 1 1 117036.0 1 1 1 1 34072.0 1 1 LI!Ll ACA I E RECEPTACLE 6 1 4 �..Ol 20 ............ ,__:_4- `­-- - 4--I- ------ +- 4---4---4---4 O.i ------ 2f8I.Oi ........ 4 1(5 1 FGIiT 1 16482.0 1 1 1 1 1 3601.6 PA1HKIWC0fL51ifS I E I E� 7 E I AC-2 I I 07036o 3j 04072.0t I I TOP 31 1703640 1 1 ACA E I 2'1 10' 1'---4'PL6L�I 4 Zo -----------FiC CL7 Tfo -- ---------jAL7EIyC1G;;j7S -E C) EFF T�E�--:-C :iliC 1 20,4903.0 I --------------;C-r-n- 7 1E I DISPOSAL 1 2004.0, 1 t2364.0 I I 20 It I t I Fi Ti 0, 01 It r-E i iFSFO�A------- ---r- n ----r--r--- - -I---7 ----- - ---------A EiC---r--i-�j Ff r i i�TNCP�CICHT�S---------r r--- f5C I Fo,f-FFCEF7T I-0j' CA 1-2 1 i- i-ji-OT6,ro I I --- - --------------E HT T F I 3i;G.i r 2e 517 .e 4 1 E I 2(T: If6j.,� r T )F ti AN I3io 1;2 �T Z9 ,I IC: f I I I I ;C L 9 1 IN I ------r- T---:jj77 j T-1 F i6r---T---7-j7 -2 r T---T--- IiOf6 FO r E it M 114 1 Lii L 1,1F ------- iMM i L I---1 1 1 J L L --------J.--L---- L L 1 I L i L-j----------------L j ---L L---I- L -fIFTTCR----------r--T---,---T r 2ir IS L- - J --J--j----------------L- -------- -r--I-,2�1 r --------r--T---:iiiCIf- -1 -1 LIGHTS E 121 01 F` 7---T-4j9j.'F -- -- -- r5 r E -CLO!1-1-1�---L--J--J------------- 4 CL I 1�51�5�..01 3 G� 11---41 -1 1, 1 1 114 -----I 1— 4' 4 1--------------AC7-9 10 Tf I t, 0+1 1 F g,19,L7.2 R: 1.11, 4 ... 2L% 4' --- 3 L�o 11 itl 1,�3 4' �KT n9t�O-------- --- ... _L __4__4......... �qT, -91 10 11f, _3�,12 __ I I 12936.0 11 20H 1 3490.01 1 20 1 11 554.01 1 1 EXIS71NG LOAD, E t 111� 1 15, 1 1 0.0 lf� 1 15, E I AC-5 1 1 17091.0 1 1 115155.01 1 1 1 0064.4 1 4 1 AC r p--q 1 151 E I EXHAUST FAN t I 1180.0 1 11 20m 1 2401.01 1 1 1 2221.1 1 2 1 AC-131 10 116 15, E I LIGHTS-ROW 9 1 T I- --------------AC-9 I I- IT --t- :- --- 76U 0 ---- -050 ---------------- -1-If I- - --------------- 2�917e,i�: S!F4.0:ii3 I 2e, --------F--- - --------------AC t 17 FGI57!� Oi"i' - 6152U, E2 -15 10 if: I I- :�f I ----------- OC9 3 6e, �s Lo FiT i DWACT6 -------I-- r, r ---r- T--- T T 'r ----- T--- T-r-dr---a--- -TCP-CONEF iCUjN1­T r1i-,iC, -------------- FF r--,-2 ------r- T---Iij3C r--2,�j,f7.-O 7---7--- I it---IL it J1----------------L J--I L-L J--- 11MO-1 1 L�IL31�t-01- L--- i -----I I I--------L-J- 2f2f( ri-,r i -CO;I;WT(FR-----------r- T--- -1 tig ------ LIGHTS REAR E 201 1-9" ff-r-Tj2(FO jT 'I 'I GMT . ... .. ------ I L I L-L-J---------------- I-L-I I--- L J J------- -L j -------- I L-I I KI 00 I I M I 1 -12 JI�6�20-P L I�OSLFLOI----1--- t1 �PWIE L' NLT 12,22 SPARE 1 122 1 21 --------I--I---R4 0�1 I P­10�1 I R ---4 4�..O' 4 1---------- SPARE' 122, --- 2LI 1, ICL..............L 2LI 1,1 41 SC!�AILTT 41------------ ........... -12 2328.0 4 "ILC-1 ROOF TOP CONDENSING UNIT 12 1 1 3 1 RECEPTACLE. 23, E I LIGHTS-ROW 5 12908.01 11 20, 1 1 5346.01 20 1 11 2438.0 1 1 1 E 1 4j 1231 1 1 0.0 1 124 231 6 1 AC 1 4 1 111640.0 1 1 1 13960.1 L 1 20, 1 8CLOI 20 1 11 180.01 "'i L R F---------T 5 --- f,r Yi-------------r- T--- T r-7---7 -------iFrAi r- if, j�; 9i. I CHfS ZiANi E E if: r251 I SFFACE W', .............. -01 1 1 I---F--I--I-------------S I�fi E 01 1 111 1 1 Itr 1 251 1 SPARE I I I T I F 2 (T I I I I I I I PARE 1 26 rl -----T T--- T-,r 7 7---I Yr-I---r---1---I------ ---------------- --T-r-T---7-j' 8 j' -------YIF r- if -r--j---i, ---------r--r----3 ii(F 16 � - -1 r -1'2dr 5fe, - -r J-- -�7 E-PLIGHT W dr ----Cliis kZiA�ili I E-,if' rf7----------------L-j--I L 1--- I---L--J--j-------------------- -L.-f- ---L--J--j----------------L-j I L L- ----------------L--L------I-L 2CL: 3,1 1, 1 1 A E 301 29' E I LIGHTS-ROW 1.2 1 1 LIGHTS:!IE-zZ�IILE L 1_P20 IL22 IL-11------ ------- tt----------------Ll 0 1 IL -,-1------- I-- I L -1 11 FI I Aq F132, 1 ... ----------- 1 130.0. 1201 3629.0'20' V 499.0' 2 , ----I--I--- 'EJR 3 11100.01 11 2013593.0 1 1 201 It 2493.9 1 1 0 311 0 1 0.0 32 1 ................ - I -L 1 11 .............IF� 1 11 201 0.0 1 OR I E -------------F1 311 1 SPARE SPARE 32 1 Fil 1 2JI 1FGIF7i'6WI I LIGHTS EXTERI 32, ---I------------------------331 1 1 1 1 1 0.0 1 ii-----I iW�WINFIWI3 I Ii ii�', ii 33 1 SPACE tI It I t I SPACE 1 1 31� --I-------------- IF-2 1 'Wfi ------4. ---:26W.+I F i+ 4it W: I I 2TI�' I .......... SWE F31P, I fi I­`15IFT�':iR OCM I III 1 01 1 01 1 0 --- r--I---1----------------r--1if I Of I I I I I I I ------r--r---I T r-T--- 'T ----------SFrACE r--,if, I F I ------1FGH�T�:EAiT I ------r--T------T-r-T -r- -I---I--------------A Er--i rf5r-1i,.11-G;Tf-fol- I 1 1 1 1 1 1 1 1 SPACE j---L LET--------r-f r---:­CF2,F6r- rO;,r ---------------- -------------r--T--- T r-2ff---T---7-i.0 7 2OT: 2 Y 1 .1 6 1 AfE SP; I I I I I I - I- -------------- ----------------- ------ ----------I------ ----- -----T--T---I-- 1 1,1 IL I I I I I .... ... ................... A E L 3. --L-------L L-011 A--- l ---IL--JI-- I SPARE 38 31" E PANEL'LP2' --------------F51 I A: L�7 L-J----------------J.--J.- I-­- 1 - .......:1�1�4., 51�2�,0, -----------L- L�7 L ��Ag------------- . ---,---I-1-1-1.---IL FI I I 1 11 1. 1 1 A�E F1401 1 21-F-+1---41 ....��A�E 0 1 + 4... .. ... ...... --------------- , I! -------------------- F I I 1 0.1 1 I I I I I SiAli 140 1 1,391 E I PANEL'LPZ' 2�.o ... .. ... .....4' ---------------- 4 1- ---------------- ­ij -------------:11-92L 41---41- IF 41------------- F41 ',�l F ............. t......... 4--- PARE I III I 6759.01 1 1 1 1 6759.01 1 It I I I SPACE I 41 1 1+ 0.0 1 W, 1 411 SPACE 0.0 1 SPACE 4i, It 20, 1 1 0.0 1 20 1 1, 1 1 1 S F i PAN L L 10/30/01 DELL COMPUTER CENTER PANEL TOTALS: 15124 11922 6759:AWS: 41 16/30/01 DELL COMPUTER CENTER PANEL TOTALS: 97267:97267 97267:AMPS: 151 10/30/01 TE DELL COMPUTER CENTER PANEL TOTALS: 10505 9505 9145:AMPS: 81 10/30/01 DELL COMPUTER CENTER PANEL TOTALS:1 40D83 I 3464T I 3133OIAMPS: 128 1 I ----- ---------------- O�5 1P PANEL'111' :NOTES: PANEL'R2' :NOTES:- PANEL'SB' NOTES: .1 If 208YI120 VOLT.3-PHASE.4-WIRE :SURFACE MOUNT(SEE I/E302)EXISTING SIEMENS PANEL BOARD 48OV/277 VOLT.3-PHASE,4-WIRE iSURFACE MOUNT(SEE 3/E3021 EXISTINGSIEMENS PANEL BOARD of 208Y/120 VOLT,3-PHASE.4-WIRE FLUSH MOUNT(SEE I/E30211 EXIS71NG SIEMENS PANEL BOARD �25 AMP KO '225 AMP W.0 PANEL SCHEDULE NOTES::225 AMP MLO --------------- ---- T T-- p� E`VT--- T -W---- -------COiO TRpEXT, BREAKER PH) ---- IK&EDT IIF,-jP L KEYfDT`Rj-1---T T--- 1. MAKE ALL NECESSARY FURNITURE PANEL CONNECTIONS. D, REF LOAD L r BREAKERL PHAR RCACE�,L&C iET FEiE�, kq REAUER'L&C iEF'Ei�. LOAD C�T, TRO, LOAD R15F L5A BiEWR EAK Rj LOAD REF KEYED LOAD 1: LA EYE L---,-F-r L No : No VA A-r-i-r-E-I&,�I 11IRPW: �dTilfk, LOAD IND I I LOAD L IS I NO CRIPT NOTE I !A I QA- A AR" NO NOTE DESCRIPTION SIZEi iNO iSIZEi DESCRIPTION NOTE I A I VA : NO :NOTE DESCRIPTION SIZEi NO, I NO iSIZEi DESCRIPTION TE r !A_I t VA NO NOTE DESCRIPTION IZE CTA JOE3 NJO- I ND iSIZEj DES [ON I NO T MIR I VA ---------r-, T--- O.j T-1�-2 1- 4 ..... r --P i---r--i---I--------WE TCT�I IF-pi�i-L r ii 2 REMOVE EXISTING BREAKER(S) AND INSTALL NEW BREAKER INDICATED. _ idr 65.0 20, 1,900. i- 71 02-O.i r------- ------iCEFTT--r r-r ------------I ------ 4---4--- - -----------FiCEFTiCt7E r r i,.iUB, E R 20 1 1,500 ri�r I 0 1 1,540.0, 1 1 1 1 1 2243. 1 F'2�,2243.0 1 N I i,,eC TCAinFoCM��i 00.0 1 1 1 ACLE, I T I T----- -------L--L-- ------ --- ---T--T------T-------T-------I----------I I -- 12,'!E�C:TEAM ROOM JAN. 3 1 r 1 12'REC-INTERVIEW ROOMS ............ Ij'720.0' 3 REC:IEAN�.ITT 1�2 1260.0' 1 20 1 11 360.01 RE PTACLE E 4 1 L 3-'L E LQLT�. -1'L -------------IF!!�E 4...... 20' ......:1�9- -j A: -I-J---L J - L-J--1 3. USE EXISTING SPARE BREAKER TO FEED NEW LOAD. 900 , 1 3 1 REG-TEAM ROOM 1 12 1 6 1 1 5 1 36P I I RECEPTACLE E 1 6 1 5 1CL:-1' .0 ----------- 1�'Rc:iNTERIELI MMS------I ;!(LM 1 10 -1 ----------- ...+1 1 1.�+1 31�.Ol 20 1 11 1 1 1 SPME 61 : 4 4 4 INSTALL NEW BREAKER IN EXISTING SPACE(S). 7 1 E I AC-6 I I 17548.01 21 .1011628.0 1 1 1 201 11 1080.0 1 1 RECEPTACLEi E I 1 7 1 101 REC-EAST WALL 1 3 1540.0 1 20,540.0 1 20 1 11 SPARE 7 1 121 LIGHTS-UPS/DATA CENTER 1 1 1610.0 1 If 201 610.01 1 1 20 1 It I . I I SPARE I I -:-7f4f r- -------- - ---I- - Ff r-,ii,i-C-iCepl,,(i--------r-f T---:-7io.-O T-,r idr----- - ---- I --YFF r- -1 rf r- -SF�IF-------------r- - -CF-i- i- -�j------ -------------jF�jl­j I------------ MCC_ L 2 1 i 2�j 2(�: Iii, Tio.0, ROOM I I I IT,' -----------------L SLW I 10i C�71. I� -2 fe.2(T' 12 ----------itF I- T--- -,r-,6r---7---7 ------­i-----------FFCEiy;CL7E r-E 12 r 'T F�C DCLCII�r 2 2 j SPARE ri�,r-E'I`RECCpj7AC[C---------- ICOCe W' I"9(FO.Of iC, ... ...:1CL7t ...I....L Lii L 1. I I U .1 L --------- ------L-J- IL-L-2J'!�C:!T�K'E!!qM------L L---I I L Z I- --- 3 E CC I 1 13 1 1,1�1 1�6 0.2 2CLt NELL'ELCR'I E 114 DATE Pj7 AC LC 1 131 10,'�oto.2 ICL: t F�CEPTACLE I E 114 5 1 E I RECEPTACLE I I 1360.0 1 11 201 1 924.0 1 1 20 1 It 564.01 1 1 ........ IC!(L 4 4........... ... ........ 4..........6 1 SPARE 1 11 20, 1 1620.01 1 1 1 1620.4 1 1 PANEL'ECi7 E ----- :iLo.p�, I IT-2 JIL0.! 1�3 B�CLE fOWER 1 12 1 14 StL . 15 1 E I SPARE 1-11 201 1 480.0 1 1 20 1 It 480.01 1 1.3 1 CUBICLE PWR'15 1 RECEFTai E 11� - -----F------75.0 IF 0--------I 35ie,W: 2�7i. ----------------iAfEF EATER E --- ---------CUBICLE -C . I I I I I I ILIGHTS -EFFNEiTCR r ri- -I 7iF; 7---I --------------SFFACE r- -20 ------ 9f4.i I 2e, 14Fei i(F: 960.0' 1,3' PWR'12 11, 17F 1�,RCC:11141i 04F Fa r ACE - --------r--T--- ----------il E 2(FI ri-,r-li,.iLi1-CL7E-PWR---------r T -,-4fo j T-11 14�Fo.-O I---r FCL7E�6wi-R r,i io r,i r,I i,.RCC:iWC(F r wf4i2.-O'r--- 2 Flf( SHEET TITLE L j 1!2 j----------------L-J-� ------L--1--- I-L-1---I--- -- -J-1 A E It 1(�' 3 1 1 L21 L 124'5-C:fAXLcT Y­--------- -.1- 4' IE 1 122, IL21 II _4_ .............�F�CL 22 1 4�..O�... CLE R 2 22 1 L�1.'1 121'�MLM fq!E----------- 20, 1 1.........ML_fq!E��_'- . 1 2�,, 1 1 1 11 1 1 1 0.0 1 11 1 1- SPACE PANEL 1 23, 12,CUBICLE POWER 1 IJ 1 1960.0 1 11 1 960.01 20 1 11 SPARE 1 1 21� 1 23, 1 SPARE 11 20, 1 1 0.0 1 20, 1' 1 1 1 SPARE I I 23- 1 SPACE -----------------t-I I ---------- ------- F I I -------------------- -------- Iii I-I- ------- - Y SFrACi t l 201 1 1 1 1 1 1 I t.3 I 14CO.Oti I F SPACEi 12-1 1 PA ------------- LIGHT WEIGH 1�5 1',1 B�ME 55!------ ri7 r-'i iFFAIF-------------r--T--- T ACE r T DASHED LINES INDICATE GGH E DUL E 6 I I r-,6,r---7---7--- 2(T,--I--- - r-n- ----T r---I- T-r-7 r--r--- T r 1---r--­T---- L-J 27, -I- L ---------------�E L 12 I L L 1 .1 1 J- - I L--J--J----------------L-j- I 1, 1 1 EXISTING EQUIPMENT TO REMAIN. I ' 0 L2L9 1, 1�� SPARE 30 1 1291 1 1 1 1,1 1, 1 A E __' A E A�E t ---------- L-L-A---------------- . ... ..... .............. 1-30-11 C1 ------------ -L - --------- ................ 2. 1 311 SPACE 0.0 AC�E I 32--- ..... 1 201 11 SPACE 0.0 1 1 SPACE FE 1 11 201 0.0 - I 1 331 0.0 SHEET t SPARE I33 1 I I I 1 0. 1 t 1 331 1 SPARE i., W SPACE'I HEAVY WEIGHT SOLID LINES INDICATE T r-T---7 --------SFFACE ----T--T---1---T r-T--- -------------7 ACEr--,-- --T iFF ----T 36� rf e,ip, 6i6 111- 61 L-A6j' r E'I JICCCPfA E- I I I I I 1 -1 F�A(�E r-r ------- -L�0,'1440.0 SPACE 0 0 I I I I- L-L-I--'-I--- �8 1 1-11,---IL 11 11---------------I IL 11 ! NEW E Q r--, UIPMENT. He 37 SiACE --- L j j.............. L- --- L-­L- �A 9 ------I------- 11,301, 108.0, 20 1 11 1 1 1 ILIL.1 A E IF I ',�9 IF I FA(LE.............jFn ............. + ...... ............. 4 4---4--1-4--- + 2 0 0 0 0 2'0'0 2 2 0 GO J,IAIER 20 20 1 300.0 2'0' '3.0 2GD. 2'. 2" 2'. 12 f 200.0 12--o 21. 2 -O 2GO.' 6GO-O 2NG-O 211.1 201.0 0'., �1400. .O "E T 12 2 2 9 2 1 K12'..0� 2 brAML qu SPARE 42 10/30/01 0 SPACE. 4f: 1 411 E PY PHONES 01 1 1 600.01 2 1 It 360.01 1 H AT TAPE ....... ... ................... 40 1L 240.0 1, 2+ 1 E 4i,' 41 1 SPACE SPACE' ,�tl L j� CE is -�I==1 I --- _I. I. 1_2 --- --- --------- - --- E103 R 4349:AMPS: 16 10/30/ci DELL COMPUTER CENTE PANEL TOTALS: 13488 11808 4884:AMPS: 84 10/30/01 DELL COMER CENTER PANEL TOTALS: 7552 4984 898B:AMFPS: ...60 10/30/01 DELL COMPUTER CENTER PANEL TOTALS 4473 4113: - - ----- . . . _ . . (�� Y U iPJ 1 12 13 14. Y Y I . j j I I I j i SHEET .WORK NOTES:Q I I I I. I I - I' I ' .! 1 1. SEE SPECIFICATIONS AND SCHEDULES FOR ADDITIONAL INFORMATION/ s (n g J . j I I 1 ! . . I I I REQUIREMENTS. N I ! I w I I I I I t I I 2. SEE PANEL SCHEDULES (SHEET E103) AND RISER DIAGRAM (SHEET 1/E102) = Q F_-LLJ w ~f . I I ! - I-LP7-32 I-LP7-32 CO D CT Z gg I ,. I I as I- - - - - - - - - - F NU U 069 I. i ! j I 4 S 2 �'�-.......I L. � �� �� NSIBL R SIZING ALL BRANCH CIRCUIT'.AND FEEDER 8 U W .Z� ,p; OR OR SIZES 3. E.C.IS RESPO E FO j i j j j ! 10 j 1B 1B a CONDUITS. V ¢ so B 2, I I j I I I I i 4� : . f m I j i j ! j j sB-tt 16 2 0 ,>�,� � 4I •` . 11 i j j ! I I 0 i' i (? y ` IQEVISIONS i i ro T . 36: ,� 1� < 1� v 1B - I I I I ' >. I SB-7 '"' ' 6 ,c I :::;�.,..... _.... �,+� I I ! I I ! to 7A . I ifl .: 1A A 0111 '�'/�l t/" / .::a, : ... , ..... ! ! � '._.._..: I ! I I 11 t ::::,j i..._ J,:..,! ✓' j 1B f��) 1. �. �1 f iB 1x j I i lPt-32 i I LPt-32 'j 4g - " ::> ,�, NIATtx -AK EXISTING FIXTURE REINS D 3 '� 1 '� i�j I it ,I'I !! , IVI a .:� !,:.I: 11AE ..... ......... ....... 1BE%� �;� 4/` 1A .... I:,. '_______= b=======3======== :!<:�::E , '" 2 ?. 1BE ! 19 - ,.I,--r- --i — — —.... —^... — ._.. 18 '"t 8'1 EET WORK NOTESriLlf i i !! ;•••• , .-. 2. EMERGENCY BATTERY BACK-UP TO BE SWITCHED.PROVIDE HOT TO 1A1A .tA 1A to to to I " ' ... "`"' °'>il 2 fart ' :"",... 1-- .� - --- BATTERY TO MAINTAIN CHARGE WHEN SWITCH IS OFF. txr I LP7-34"`i1 Ir^h'i -^ ,y w "�I '>�j ! D 3. FIXTURES WITHIN THIS AREA TO BE DUAL LEVEL SWITCHED.ONE SWITCH L... :.<:!. ! 3 F...__...._..... L.........._. I>...A �., I ... 11..>r, .!!! I I"i l!i a"1 j 1s TO CONTROL CENTER LAMP AND OTHER SWITCH TO CONTROL OUTER- r, I .._<, _ to 1A lA «.::.',! to 1A I I to 1A w 1B „•�!._....! .,,.>.I I,,;,:,.I LAMPS. j ).....t"� i I - , , , ! ( I I`'":: : .'a. 'a..l I !1A' i1A 1 1A':: :::-# .., . 1A 0 1BE LP7-32 _ » I i :-i ! r'" 4 or 4. FIXTURE TO BE UNSWITCHED. ......_A........_... ..._..........._.,......._....._._._..._........_< ... :: ' ,I 5) „ i I n '� '_ =====1=====-_- - ; i ...A 1- 3 LP7-35 L.... .....,:::.i...; ,J I; �,::::�J.:. d. '' „ 4AE a "'"' "" tAE I : - I tAE tAE >`" � "' S. EXTEND EXISTING CIRCUITING AS REQUIRED. I I %N II TA .v:L.... .�:.fA::'r.'u::. 1X 1X 1A 1A ! 1A., {F ...y° ". 16 �.:.1. 1A_._ to 4A , <,, 'V II :, '. 1--- --- I i, -I I 1 iy — — — — — -- -- -fin LP7-32tV'z 1, ____ ___l===t===1- __� 2 _ - - •- - ---- { ,,.: a- I .::. --1BE- 1x tx `• ""�•! i 6. INSTALL EMERGENCY BATTERY. BACK-UP BALLAST.EXTEND EXISTING 'SB' ' ! ! ... i ,<::.> .! 1': ! 36 38 1 T T <s::,/! I I >'4 �I I'j' F!I r I!i """' ° _ _ aA CIRCUIT AS REQUIRED.SEE.SPECIFICATIONS FOR EMERGENCY BATTERY 1x s s6 a s6 --- _7--- --- --- -- --- - --- - H -- - - --- _-- --- - BACK-UP BALLAST REQUIREMENTS. o o ! :.. T -- ---T -- --- - - I tx. `) I--- LP1-24 - , . 4 36 ----�----�---- ---1•---1----1----1----1----1----1---i --- ---- 4 lPt-20 ! ! 4A ------- ------- -------- '_______'====_=='=_===_____=____'_____=_'===}==_'_______'_____=='==_==__'=______'_____== ___==__'_______'_______'_�_==__'=__=___'_= _=-_'____==_'==__< 7. LOCATE,INTERCEPT,AND EXTEND EXISTING HOMERUN AS REQUIRED TO -1------- - ----- ----- ----1---' _ _ .» « , r » .. , r.- -'I _., r - FEED INDICATED LIGHTS. _,., , a I ! .1 1 4 A .1.....-< :. _Ikr. , P. ;; -., ` 0.1'' ;?'f '-. )y *� .""' ''`. ,t""t""','f y '` """"":.. "t'':M1 ?"""""- `' 8. MAINTAIN EXISTING LIGHTING IN THIS AREA.EXTEND CIRCUITING AS REQUIRED. II ,Y,' :"t;U , ,.Yip i ' "M' ! 'Y/ e'a• �i' V:� 'w�.: ' ik% ,/ > V. f l I ,'i _ _____-- ROV�16 y" ! "'SB-1 i , SB-1 ! "T"•i -1 i� ,•% i ,I ________L_______L_______1 _:______r ___L i___,L___ ^ .. "� - - ....-„1,;'__L_ ,:?, ...-..-.:.._____r._.. .___ __ --_ -L__ _�L„�____�.�.....=.g.r___L;.--; -.t, _ _______L:,,'- ;,p,.-,:-L___1 �� ________ __ -. ,,,..A, ..,.-», r...... . ... - a R r____r - '_ t f ... �....?E:.. ,., - u LP-i ; i ! T i € - I �i I 9. RECONNECT TO EXISTING CIRCUIT FOR THIS ROOM/AREA. - . I I ' , i �, k, 1 (......_.. a:. r:: r� a. t, o. r !a„ Jt o. rh:. t tB s1>. a I I 11 n ,_ -S:. 5„ ,,r..r �;.ih .I :. 't,:;': to. S.; ';.. .a.. 11 ....... !. '. 1 I , s ,,f �• 1 ,', '::: *:�-'i 1 .� k'. ! ,✓ ! i^*..<>' '"'':`--• �``1.%�'`--'' .j" .'l..X '. <,''i °>.:v%' sA!•` 10. PROVIDE EMERGENCY BATTERY BACK-UP BALLAST.SEE SPECIFICATIONS I I I vA :�£ : 6A ` w < x i I p :»., ..,d.,.,.,..,,.7».I .,,.' I»„ r,,,,.,.,.„m„i,,,. .•,,..j.. ,,..»,, I.,,pm...� r,,,i,.,, ..4i�� ..,.i.....,. P„m�., r„A.. J»:, FOR REQUIREMENTS. o m :,. b1 41 II ROiM 15 ,!., :b '`J. �h '�` I {-? ',i" �' n I' rti..,. '•� <Y'Y fi i ,,,b�.. frl ---- cocl� '11 II L1 ________L_______L_______1 _ _ _ __.'C _s _ _ _ .;>-,,'f,- •C + _ - - ter$ ` -+,L :Lk:r _':,;_wZ__L ' _ _L__ _ C_L -- '._ .,y --'�,,�'.� ,ql _ :ct -,1- �'.L'-- , -�.!-:,, - ;c - 11. APPROXIMATE LOCATION OF EXISTING HOMERUN. ,1 II II �s ''1' !"ztkR. „l.r: ;.. rryC� r - 717; :.,-�l'Y_..._Y g-....:r n! - N .,I�„;r , - i �• Ic`.� ♦., �`��` M I I I I I 4Ptt3 E ' I'"� !1 . �y ., i !�,k,,. ! , ' �/ ... .. .... i ;I y .. 1I II II .,�:,.. ' ! , I .,,, ....................... <», ,,,, ,,..in.. ,.,. _,.<,,.. ... .», ,,,, ,. ,,,, .,.,. ,.,, 2 W""I I N j 1 . PROVIDE NEW SWITCH. INTERCEPT EXISTING HOT AND PROVIDE NEW II jI ;; 1 ! j - - - - - - - - - - - - - _ - -_ - - _ - - CONDUCTORS AS REQUIRED TO ALLOW SWITCHING OF LIGHTS AS y c u u - ,. - - - - - - . - . a,,,, •, A - - I - P,,,,, .1 - e„ �� -,t�, O INDICATED. 7 p.. n n u »,I f,:,, ;,,i WW,:I '„ . ,.I. U1-32 F—� co ! :� .>', :n. r,:. :n^s .'S;; .�., .;a: _✓�'- `r='-- - ;., _-.rl.. - - ^•'--- --."' - - `---;",ll. - —v _,rL"4.-„ ,,,»,¢'?L_ .J�'---<t-c _ --„�'--I---"'- -- 5 �''t. II II II L_______L_______, .... ._..._._L_. _..._...._.._L`r _•-r.G... __, f _ __ __ _ _;L� _ _"y__.. __ _a_ .___L___r>J.-o-.-L;H__ ,___G...-_ y'_ L iy-..c...^_•"'~' _ _.-_L__ _�'_ _y__t_ 'y._„- »__L' __ _,r L>,r_ _ -------- -, g `* . .. :� at ,F a.. :;'* . : �.. :,: rF T ..-i.... ; .... ,_ ,!9 a:.. . - -.a1 - 3. D INSTALL NEW METALUX r1 11. 11 a::;. t- `.. , r :: .rr ..;f! <,:• „r., ! ..;: :::'a'-1 >. yI ; r -='e:,ra , 1 REMOVE EXISTING APERTURED REFLECTOR AN w li R4� L s: ' / oii I a%I c o / �i. I .. /! w `r �/ ! ! >a v a " " I ' �' ' P ! !,,,I 6 "DI-SERIES" APERTURED REFLECTOR AND NEW METALUX !'MECL-DI/RS" ,1 11 II ',:ro f.,' ....d»,, « .......am. ,n,..,J».. n,++L », in .d„«,»»»», lm._,<� 1 «1,. , ...,><.+:k:a .. � » . I .. I n 1, 1 i ! P ! ! ! _ ! ! "' ! L- SERIES EGG CRATE LOUVER. TYPICAL OF ALL FIXTURES IN THIS ROW. ! ; (��^ bJ bJ I da ' .rT"I ,^!;, ,�, .r' ,I"e !'::. .I !r .r•'*. 4,;. !,,, i^:.. ,,,i�t. r�rt,:. A:"C. ! I n"", »„ r'k5A . :. a ,:. „ .. REQUIREMENTS WITH IDAHO ELECTRIC SALES. u 1 „ ti :�4 �............_ .................. -..._ _.. __.. _ VERIFY INSTALLATION REQUREMEN S :. ._._...__ . 1 1 1 4. i. tt, .: .,, :.. !: K "{e % I .. ... �.. ./ .,3 �,>... . i ..� I. ,dt �+,:;. ::7 C?., ^.'?d' �' C% .n{. : :,::; <., I 1n,. ; ;r ;: - - 4 - KEN TER. 11 1, 2 3 , ; a a rr ! �: f rI vv "!iJ G a'!, ,, "%::., 208 333 307 E BUTLER. 1 j I I I I 1 QW-13 «,.,.�...........:.... «.: .,..,e,». __ ,..:. .,..iI ____r.,d. __ __ _ __ ____r_' �_•t_ _ _J",.k..»,' '� __ T ,.....,i.». o„n,,.,.. _,,._,,, ___ - --a----'L'-_ __ L L__ L L ---_=L -- __L L,n.,,.,.. __ L__ ,d,.:,__L_`_---`- - --L",.�_ ,,,.,,w'„qL___a-- L ),y 11 11 t1 ' - --' ---- -- -- - AREA VIA AIRCRAFT CABLE AT 10 A.F.F.1 I II ________L_______L=______1 - --_;___L:__ __iL___ __T_ _ __±__ __ ____ _ 'wi _ I i __ ______ ______ a__ L_�____aL_ _L_r__ _�__ _�_2 M S -------- ------- LP,1.7 I k " 14. SUSPENDED LIGHTS IN THIS EA I 0" �+�/ t;)z h a I. a y' 7 e i. .r... 3e. t. 2. I a II II I •::. :. .;... ,1a: b,.. ,>' �•'\ 1 :i �.t* .d ...W F: "'3 "rt......... ,%'\.. ::•e. u L1 :: L,. .,. : /.?'I �,:. .:'� .. 5 .:� ., . : ' n. .. t.. : .:r ,...._ ._. 'ih :Q.. LLI a a 1 rt' r a j co 11 u a:' £, 4. v C: y: ! / I yyl r;'! Y .a �y:•% �: 'I ! ;' / ... , h% ....... I „� '.. O I ! v ; ' a.. w. I, 15. SUSPENDED LIGHTS IN THIS AREA VIA AIRCRAFT CABLE AT 8'-6" A.F.F. I/�I0 p�Ii 1i Iu :,. I �.,,: ,;.,,i . Y.. .I �.<C M I :7+ ^ -< o Li -I 1 1 1 ra „r ..7:;,, it <0.`:. s :.. ,:.n.: .7\! .' M.g.. :7a, t,,,. I EMI' i<' n f'` I I a . » _. ,! I t '• ; .. :: :a: Ia f .<:\.'ti§ .. /' vx._.... .S._. _.`` "�3 Y! .... f,. „4.. "'J i<:n ..... K. x.............. 's' .x..............i .........._-..zr .?� ...I...__..L. �. t..... _.....r, . K:,�"..x'.... ...F" ';*'f - - 1 _______ _______ IOW'12`::,"' __"g. _ + __ '�".^<'___ a> ,F 4'.�"`{ _ __ P _i,+ ^____'". - . k' '.!'__ __�r - `>p_ _ "P._ .a.:G_,__ _ '� ___ __L1=_ ....L 1, _;' o-_ ----_ 11 11 11 ________L_______L_______, ______=r_L ______Ly__ __yL___7.__ __ -,'L#. __a__L_i__ __ _ _�__ _ ' •I __L __ _ L;___ _ -_-L_e____�_ _ '__Ly__ __:L___a__ -rC_ __1 �p j} �y N .,...1Pa-9 4• J b»,..... . $B-1 b,,, ,,,•i L„»»»,5. k,»,»»,,:,,,.,,:.,J BKd,:»,. - W 12®3 d : B- �__„. : 7 = i 11 ,:m. . ! '� m,1 rxa :;'. ;,:f'2 ::: :, h,,�@:. j "+^o,.. <„I I <,v:. I I r ! I �. ai „' l� a -- ,+ ,� )Y N. .. '� +fir`.` .!� 4v _.... x :. >r'%" .t._._.....:�rr" K/���x< `>9 s - - '>�' �''� _ �::H `X._... s. _ K��..__.I II s ........y'. .., ...........{ ...... ( .. }........._., " ;J I ;M..... '', .."` ' M1'G II sA .. .,` �F:' �I:. sb 4,'L"+ , , ' ;:� i°' x.r 18 LP7-31 >A @a �!f, .:y'r;,_ ...i,,�.. "^ .t..-... ,,fir., ,c ;. �, `S^•, '*I • 1 .»,1.. »,,,, I ,,,,.,,,� L•„»,..»„T.w.i i r ' ,,.,.� !,»r,,.,., w,,,� ,,,,,,.,,,,, ! ,.w.," I ...L. :» W..q,a ,,,, W t SHEET LEGEND ____=___' 11 ROB(:. tt .� " I rj_ I *. } __I "=''- -----;`' ! wa �.,i_ „mil-: .I -- - --f.--' - --L-- - -'-J-- - ' 1 S. -3�. _1111— . L `A--,�- _ - ----=1 " ------- L-------L=------1 _.r_ '_'.L _ R:. _L.<-�T`- -L M= ..... I - -- Z _____-_1 to `-�,i�...-_._.`� -- - - ?-_-- - +- - - - -�.• - ._,.. ,� ._... ---- LIGHT WEIGHT DASHED LINES INDICATE ,I �:. --,f..- � *..- --- ........ "_.. t --- L G 1, ...Lt,�;1a1 -J •`",G'' . .0'._!.... Y .:;*<: 1_1 t9 "wr" . .....f'/ +c.y r.G e,_ "a:! 43 1____' r, : I EQUIPMENT REMAIN. ,». .,.,,,,,, }. _ ..�,,,., »I,»,,.,,.-11, »,.»,,,,,,,,,,,,J �...._ :...,,•••l.,,,,,.,,jI. » � � ,._ w»„». ,.�` (,»,»».,, EXISTING EQU E 0 <. 1B s� � U t� j j _ O HEAVY WEIGHT SOLID LINES INDICATE 0 � ! I rr'' L� u I 1B I I I LP1-32 ' 11 ROW 10 ' mmmmzmMmiII --------L-------L-------, 3 L-------L�.:F_=i��•G-------L-------c ------L-------LS:J_-3^SY-7 =-_==-==L=====__'=LLLL=L =-C�_L===LLLLLL======L-LLLLL=1 NEW EQUIPMENT ------- ------- ------- -------- ------- ------- ------- ------ ------- 1 I »»L-A.,fi 13- ,::::, i,.56,:.. ;.—-—-— - — —•SB 1—-—-— 78' ! ;,c — ,::.' . , o O : . .:SFi.:, l.., r,w ,:F'y.. :r^,::: v r'"a sd"'r;. ::r.:* , .,@G, .;d,;� ? , �' 18 I \,,, »,14 .L,, .,,!`,,. ,.^�„ .f*.:: .°"' ..... I I 8 k.:? ,,. ...._ :. �. t€. .9._i._. ... ft_.__ I I r 4r .{........�:. A ; -12 I I I t I „ i Ij I P M,,, r,.M »,, t„5 y - �, „I J.. t k,„ ! w l I i I ii _______ _______ BROW 9_.r't-TM --- -- -- -- --sir- - ---,+:. --�'''<-LT -- --.t -- -- -___=_=' t --`,:z L-L --_L-+~~�-- -- '1'S=LL:M-- -- ---•'�•�- !L=-=t r....._.... .. a......_ ",F......., L'%t1-1J t k::. ,r ,X: t :x ti: �;, :'>? .,n`.... ._o .•,.d... _.. J ...c ._._.. '� :R W 9 I I v J ,I : I,,,: .,, ! 1� ' .;fit:. ,I",•:. : *., � .,p �U�>' I'�' `<:c'I - >'% + <a'' `.� 1/ `... `! ,°I 7 ------- is- r r : ! I r I ! 1 ! , TORE _ i„ ! ,i� I : . Lu I, .,,,;1•... �.. .;St.. a . .. :A" ..4.-I .f,� L,t'.,., ,.,:»»ye FIX F,.j�;. rr,::� :a'r '4, .;�, :b �- m<:1 'Yl .._..........x .. //: y._._.. �/n y ........i, �. 5� ......�✓+,,�. y._......._-t F x TAT 1 `:a �y S 3 '`,7_....: ILu i II ., ,y \/' le.��j% CD. :/°, G:;.�.T .'„3 %,F'j ,t ". .`d/ ,:.; 'I�=� �•l` ," r} )p +u, :a-• 1. ��, I I ______ ROW 8 , 'w '�:'`, I ,;«r I r' I !"w' d` a I \✓" .. /, „�'B-3 I I �" ..._ eR:, '.0 R! ,1 ________L_______L-______1 ^^•- _ __L_ _L-L- 'L''^"'_>___ _-L_ _L___ ___ _ _L_:__ _ rL_____ _ - __ __L___ ___L__ _ 'L_ _I Z SB-3 I :*rt '3 L 1 17 ::—:sir r I ,a, ry.,, B rzc '1�,F;. x.! :.:a , l,r:>• I i. !.9,. ,e:::' ,!. i > .k. ?R W 8®3 16-. r %:,, x u .. ''ji p 'i 9+ (%%{�" _I "' °'. ...1.. C;' .•: :t-Y.... N';N ...X 73 _- w 11 �//�`1 ,I i .,�i 'w1� .r '.•f' u..q •'>}..,:1" . .a.:111 .F` 6 .;,, :,,a' ,w v:, .F' ,yr........ <at, ,,�i' II : I I I ! ,: I f 4., ! ! „ I I ..i ! 1 1 n „ I ! „ . :::f L. f „ ' `I I , u v "a , Ia. I' 1. rn Gr' >�`' I -RJR /rti[�C. _ 'rt _ _ __ _S.:C�_ ....._*_ ...... _ _ _1 +.,4'.__... ,,Y}� f=_*`'"%`_ -=:!l =v - 1 '1B cr II - ,J ________ _______L_______1 _'___'___ _r- __ �`__L"� __'*L___T__ L_ ^__ L. -- �"`� S , _ -q _ __,�,:['-- _ -':y,a" ==>y ='.F.:--'. >' __ _L�`1f__'�'k'- _ __ __ __ II __ L _ " ` a__ _A T __.__L_ __ __Y,`.•__ _ __ __ _ -L`__ __' �L__ _ _L _ ___ _ __ _____ __ y_ __ _LT _ __ __ ___1 LP1-79 r I ..... i . J I <, I1 ....,,.<,,,. b,»_--g-j k...-...,,,,,,,,,.,J I,»,»»».„y„..,J ;.» I , :,,,«.r,. J L ,,.,.,,,,J IL_ m„J 6. „i ':,.,..... .,,,,,., >»,1,,,,, ,W,.,_J- I ��+ u L L i W � l:.;;,r,,,,` ,i gg G' 11�15 v' Ir......IV, y to° I hr a, OF//" y��'�!y<^^ ,i,ri' z@yr '�% I..... ..;;r y,5 �. ':.y,r' ._�.':.'' �,`:iy�'._..s. p. �` i 'r`y... -1 w ._..... � ' i ii ROW 6 _______ _______ _______ _______ _______ _______ __i____ _ ,I � • _-_L_______1 3_____ _L______ L_______t____ LLLL L L L_______L___•`---L_______L_______L _____1 II ,d, "•......,' - i ii ri ii --- - LPt-21 -- - r---- j--- ^ ♦\ W II TO I 11 I I I ! WII 'f,' �T I T u L1 , I u �+1 ..L� I I 1, r.l 11 I i I ,..... 11 1, , I II ::: :, — — ---1---- — — — —•— — — --- — — — ------�I — ;1B- , -----------•---•—• O I1 I, , I n ---- - - - ----- - -1•---•,8, -,- ---t;,�.,;.- - -•-::,: la» - - - ----- -„- -c4•-•t.,,,;,.-:,,-,;,--- - - ---• .,- - -• ,;j » I;,1`9, .:.• . a .»,,» r.,, :, w.,�,w II II , I II : I t I ! J rr I,,. X ...%�v a V . ,-. y /. i y! P. t (( S I I I I ________ i .. y_ __,_S;r__ >__.,. +__ ____>b"y_ ,r.... __:,2' 3,. _ _:� _ -;t___' 1GP_}.__ ____,,,�'!,._ _____ __i!.___;t' __ _ 1_ _ �_ ' _ _._�.r_= I 1 1 ' ____t .... .,:,. .,:, __. __ _ __L____:,>_ L.�__ __ L...._-. __ _ _'',;- G- . _ ____L� _ _ _L_____+ .sYY_5,L E.. _,� _ _ _ _ � ^' I I, I n --- + ,.-,� 'o.. ._- . Cv :.'T 3:...a1` ::� '...�. .,,..tq.s:r •'r"'.' ,-ar-- .._.'�. '..a> __t. ; a; == -- - *�' "" -r: ... ..r:::i L.L. 0 N ' I bl LPt.�23 ..,z'! ! ..,1%'! !'. !`y� --fi .,r�.�' I ,� i"'i I`+F"'' ! ":,`' ,'.+„r ':,/ '' w y," ,�' ; , •tr '...... pow 5 U O P. I I I I ! f,,.,,,,,,,, 1 i 6 1x rn A. i. ,� i. h & l ••i 1` i m C. J• 11�� •A A .!'!. .d I 1 ,I 1 11 ,>'F.. •' .;'., :i' ,.,:�.. :.'/".. .� b.. .a; W!. .+fA<:, 'V_ _:/ \: _. �, l I 11 ,1 r�. .T , r, , k'. t--•- 'f ', �:, , �' }!` :- ?„ , 4- K -...1r ;:, ,: `� •• { t :;I n� ,?'.... :,;X. .t..........r:. .+ ,�..� Y� t�'>'1 I /J, ,. ;h•.a :;.%: h.:� ...._... ...� ,,Y' I -...N.:>i ...v: , ...5 i ':,,/ �,, 11 4 L4 I I i i r-I I I , �k>> h.: :� a I"•.k!' as ';,1 .� `:u I x 'a,.N I u ,4i' j ;�'. �'•'?I w`, I jS` , v+ `<s:> ``37 j v!% I i"•• „,,qE . 11 II , 1 11 1 ., n,. .. .- .», n:.: n„... B-.3_ <=+ __ __ _ _ __ ____ __ ____ __ __ m_m,tn, ,�,x _ ___ __,� SB 3 .. ' ___ _ __,�rs„-__ ,,,i,_mm__ ___ __ 1, 4 4 u N I ' ''' --------1 __ +__ r J.�Z i' -- --L-+-- --t'^---- - ---- - �-L__�r' ZZ -L ---- -L - L--___ L_.J';ai- L- =. ----L-'-_ __iL-- ---1 ''/:'�1 ,I r-1 II --- ---- 3 _ -. _--�-- - - •I"-- ..nm< , I ; I -T �----�- -F--- ' -r -= 11 W �•+I _ _ J. 1 LP7 5 •t .d• 1 i : /4, d'@ M .,I 1 ,1 ROW 4%°*. .. .x r y .......t,, i' ._.._........'' �`.�1 '>r... x<._.h.. •_,1,,. c.>, r ........... _.fin'°,r ",*,,,r..........._. .� n 1 1 I I 1 �` � 1�1 I I , , ;a c<. « :?� n.; 1 :-- t:.:. n; l'f. �, ', .r F;..a; K. :o.:" :.. I,I::;. ......�: :;.%�'T .,f ....�' , 11 11 , t U ;: uyr.: 8 ,ti ` r' "N" i�<:sf' ":fir. I":v'''�� o. !.,; �e , ">�" ' ' t � I v'' '`�' x .. i ::7 "'7,;''i ;:::i' , •a ••};:; ! a' ..r.::: ) I ,I r I I ,..,�,.. ,,,',,. , ,i v.u,n,-. I, „nl ' 1 i ­4t,I, 11 II I II ! N,<C,:, ,. f,».M <.,i ., „I' i» , ,� B.iJ nn :11 T R r�. m, r-:. 1x. �, r s r3a, I '�I y , 01 F q E .c pp „ % _.k` )l K... 'd........_._� .. C'., ".-_-.._._.{ ;:" .... {.. ` ,j........ .._.... y I 1 I I __ .,+' -- F-- ---"f---",�- -� ~ 1 --"F- ='� - - ._ `,FJt..L'� `_�,y� - -1 �- �F' --'4 - -A�" -- ---- --- `-- -- - ��------=t II _ � h o d 59 t I , ____L_ _____L_______1 ______ _L __ __L' __ __�L___ __ L_ ____aL. __+__L_ __ __L___ _ __Z____L__ __ _L__ _ _Lr___�'� __t_ I ____ _ __ �_ _ _ _i_ _ __ II Ia I- ' i i i --- - :-27 „m,,,,,,i 6,» ,.,J :.,.� L»«.. J .,,..q„J i•»,«. G...,:,.:W:,,..y,: b,»«w,. d L.»»»,.,, i i _ -- '�`' 1••44• 11 _I „ i -... „I ! .<^„ .9\i ,,.,.,',.ice ,i„ ,,:x>. .,+.,::, .H'<,,.r ;:,'�,>, I i , `'�* _,_� r� .1',,, ,o`"`;:, ! ' !''."`Y `"/F''! r `u G�''a �'! Cjfi: k, w, iL `6 ^I II �' + : ,.,,,,,; W W:.,.,. ,,..,, ill 11 U .......1. ;A f yJ .,.--...__. .. ,x.._._........L „' 'yv' ....(' :S $„ ._.... ...i ;.... ``+, t�' '\._..... ...y.. ,}...,. _+,,»,. t,. / d ,:x_ �,%,y',,> .ak `Oi' A.,,l w.n `,.f' 9' l *t, 'n G Rt ti •_• k"fjj `):YT ?r f �L, ...t�+A,, n, I I 1B 1B:. .... , ....._ ... ... ..._.. ._....... _. 11 '5)l i t i ►X ,,,.,1-J, ..,.r:r .,»,»,»» ,,,,.,,, L..:»»,:�:,,,,J k,,,»',» ,,,, r, ...,,,d, 1- M.,,,,,,,J .,,,»,»», !.,» ,,.i 4», ,,,,,,,.Jan >„»...,.... >,,,,<»»,,,,.,,,„.i w .,,,,..,J '.. ., 11 L� LPt 32 ROW 2 58-3 ,,-. 4. _ _ 3_ %•�„ r. _ <{B 3_ _____ _______ _______ _______ S_B-3_ _______ II II II ----C-___---L-------1 3 - __ ---L------_L`.:.0 ai��L-------L-------L- L:LL4 > -J m __ - ",1.':`_____L 1... . M:^� i-� = -, -;i ....11 LPt-4 11 i{' ty " '.o i! "°.!.`','...... r......:,>/'r ''� '" F: ,t III i O \ONAL F I' U ,I f I i O 11 ',,, 1 ,,,,, i I A LP7-6,8.10—�' ! ii ll! /• �trI tSiE L O � I *LP1-2 I LP1-4 (TYP) o a », •Q -.+4� -:.�:,,,... u6 0 r I 2A ,? ,.! a 2AE S .... q 1...i-�, ) 1) 1) 0 (�Qt �i ,'' i 4 ROW 1 1------ ------ ---- -- 7--1-L -- ! (.ti -- ..;: I i. - P7- r ., Y�Ji +. / .:r 4 O___-LT------L_------L-------L-__-___ ---x'--- ---- - L-------' ! �Y'"F `ii I ::.7 i_-;I �, 51�11�j/G 1 I ............... •- g.A.... ® I' 7 „ 1x LPt-29�� 10 ! """"��': cl ;u '1`.•W -f'n >a 1)° t) TF OF G !LP2_g ^ I� (( 149 ---- ------- ---_---- --�-- -_-- --- -------- , .I_..<...,.,.1 - - - - - 9� , . . —_____ ____-_--_—.__—_—___ _ _ __—_ _-- _ __ _________- _ _ _ _. _ __ __ _. -Fn _—, __1: ___ ....... I Ile n Ij::::::11 �'}.:::::11 4) t) fit) �!) fit) �) �) fit)• a 4�)i� I 2A 2A 2B II i1 '``/T�7\f �, `n! -J %v'" ''>�:,..,a,r -._..fk - ` n -- ---- ,r I „:.....:1 .....;! ...-. ---- LP7--- .... : :. ,+�� ....x I 5A•' SAB 1' LP2-10 "Y s...x .� ... , . I ...... ......._. b ... r•1 i i A JOB N GT O `Ii I ! ! ` " Ib v •'r =I I r I! i !I h .. 4 L J b 2 10 I, m,,,..,,. ,) / r--' °w, /' 4 I �,,r„ , .,...._ , i .... ---- — — — — ----- — — '+ ---•— -----------------• DRAWN CHECKED I...!t 2LE ,�-� I '- \ f,w,• i 2 1 I 2AE 28 ,,il '! r' b b b b L' KBB SLw ! , 1X 1 �I I i t I .> !�' b b b.. i. i . ' I - -------•—•—•— •-- >rI DATE . I 4 40 t \36 —"-----------\ \ O 10/31/01 Ii Ii I .. ! ,. ,. .. i .. i (TYPICAL OF 6) 1 .,. (TYPICAL1-1 oFj to) ` ON SHEET TITLE 1 LP2-9 LP2-91 LP2-9 LP2-9 LP2-9 ^LP2-b LP2-9 LP2-9 I e i I—•—.—.—•— — — — — — - — — - — —•-----•—•—•--- — — - — — — - — — — — — — — — — — — — — - - — --@p LICZHTINCS i j i j PLAN . j j i . i . i i i i SHEET C 1 I ! I o 0 Y � 4 (: 4) . , LIGHTING PLAN 2 01 a E201 ' SCALE;%"..1'_o. NORTH m 2 3 11 13 F¢•t=z 11 2 3 4 10 a u3: u o Q Wmom �Z W A REVISIONS --�- -�- ® _===3 C ® -® -- n- t Ittftlzt ® ___-_ =_ � 8 (] ------ [� - D------------— ----------- LIGHTING PLAN 2 LIGHTING PLAN , LIGHTING PLAN E202 (FRONT MEZZANNE) SCALE/e" 1'-0" E202 REAR MEZZANNE) SCALE:%8' 1'-0" E202 REAR MEZZANNE) SCALE: GENERAL NOTES: 1. SEE SPECIFICATIONS AND SCHEDULES FOR ADDITIONAL INFORMATION/ Ln REQUIREMENTS. �Ar' m m /ter m 2. SEE PANEL SCHEDULES (SHEET E103) AND RISER DIAGRAM (SHEET I/E102) w FOR CONDUCTOR SIZES. E--r wii c 3. E.C.IS RESPONSIBLE FOR SIZING ALL BRANCH CIRCUIT AND FEEDER m x CONDUITS. ¢LL U 0 p wm x Lu co c p Wo SHEET LEGEND ---� LIGHT WEIGHT DASED LINES INDICATE �--( V Z ----' EXISTING EQUIPMENT TO REMAIN. Ln O '--, HEAVY WEIGHT SOLID LINES INDICATE ^ ^ -a NEW EQUIPMENT. lJ J U) U f U � . Cie W W p Q Z U � Z oCpN W w V) � Z U Lu O � U wn < Q cc V Fy Zg`O�l Fti TE G Ci a Q�s�/j�JoI�5 • �,�),, of 9�qN R BR�G 4 GTA JOB NO. 5 DELLGG DRAWN GHEGKED KB6 BLW DATE Imiwml SHEET TITLE LIGHTING PLANS (MEZZANINE) SHEET 202 .1 r 11 r11 1 2/ `j J 1 4 1 C Y - 1 2. --------------------------- \ f/ \ ,/ �/ 3 Q4 OR SECONDARY COLUMN ' Y Y ' '®' LIEBERT AC UNIT � OR SEGO DAR ( , DATA CENTER I N \® ONDUITS TO i UTILITY I I AC-10 IN j j I I ,� I MEZZANINE ABOVE ; TRANSFORMER-v y I DATA CENTER® I :. ROOF TOP ®' . . r ,. r - - IS N N n oo D S G T I. . I I I I I 7_ n N N n ?n. I ' D 11 ON EN IN UNIT . Ln C!I s I r I I D`t2 C [VV-QC . .1. I I I j r�`------ -i n ri ^;In - I 't1n m , . I ��- . . , ,, .. I // 11 N M N M - ' 1 < . ! I !. I I 000 000 11no 1 � = QWW ,F F I MSP 1 M-20 22 24 qq I A- V2V • -. I j I j j "*,.l1_3__ll_" ` _ - - - - - - - - - GENERAL. NOTES: V • j I 1 j `IiH-33 / u s s s j j 'c o -28 '--FIRE SPRINKLER. �/Z W C�i I j s s z z 3 e 1 IG B """ "" RISER• REQUIREMENTS. N CHEDULES ADDITION F - ON/ E3 Q LJJ m m= a 1L �� rp 1 S ADS FOR AL IN ORMATI 11" Y '`✓ i ! I i „ 11 z3 za 35 �ZS92 PPREELTION �`a ,' 2. SEE PANEL SCHEDULES (SHEET E703) ANDRISER DIAGRAM,� 0�I t I I 5 Data I ` (SHEET 1/E102) FOR CONDUCTOR SIZES REV NS I I I I I I i', ATS 'DC' �= e •1 "'\ro.,. -7 ^� .. ^ ✓' Y I I I I I 7L-at -1G,h `\� NP Ds� `r\\ 3. E.C.IS RESPONSIBLE FOR SIZING ALL BRANCH CIRCUIT AND FEEDER j - `3H-28 :!6::, I i' �`'.:' -h3 o-0 � CONDUITS. . I I I K-17,19,2{ E r!!IIa1„!!!:!q ftimut j!!!Gr uP LF.). '! ..'i 26! 1 :\... 11 ....., I I I K 15 1•: .r.. 1<,:»IV ,., 07 r t "I!!»=:,,1' ...j j < �, �� � �'`/j . u ....:.,.� ! H-24 . I I. I 48 T4' T5 I r . . ! z. ,1 '18 9. % ........j !; II, ; :: ! r;:y. , ""'; "'r^ ,r (�(✓�� (��{� a,t ;8 T 4 SHEETEACHODUPLERK OX EDEVOICE TO BE CONNECTED TO A CIRCUIT. -, UH CF 1 i :.<:::, < i<.»r:i! ,,<:::r I ;s, q, ...\dy .>:1 ! i :»!n I:� 1 zz h,,,f" ti'�.,�•.;C\,.pl H ,12�'• . K 1 _- Sw'�' aiH-20 4 roFI i !!:'a j ;ii.a tlf Ii 'I;1 jl III I !; iT,,.r,:' 1 r ---- --- -- - - - _ - B os I " '•.::::iui »a I a 4 11 (il !! r 2. ELECTRIC DOOR LATCH AND HINGE BY OTHERS. E.C. TO CONNECT. ,-a ... „. .::»:., �_..._{,< .J<6 !.__.a __�•<.:... •.l.-16 ✓ ' qi'=lI I_._.1•<.»!il III`^j... i M I. j a F+--�:4 T,. 1:»!:> .. . .. :: .:!x»1aq ,..... ::::::!; F( l it »�, f,<:::: ; C.:»:•s ;<._:., 1 »»,. �:...,I » ! us.:»>I - - - - - -._. PROVIDE ALL NECESSARY CONDUIT AND CABLES. IJ IJ I: �; 4 r::-1_-' `i '-1---- ----F-�!-�I:-,. I!I-� - ! --:�-' --'' - - -- -- '" �- t-1,� j... i--+J--- -- '8'' - - - - i ..... _...4 x...... ...... ......i...... :.,,:� <.:...9 <::::!o »! - - - - I; Tiii"'I -(!:»;,1- fin:::. Z• G 1 , i<....r I I ,A1z D7 I u!:»:A�11' »»sII !i a {. ................ . )' , {" ; J 'I" ; Ir»::r !<::::°, ;.<::::; 19 : I ir.»r,w !::::>,; Ia. !ol , O I:I I ;,._Ifl �....i" I'..,.m1 II II!I Ij IF I w, M_1µ 2 »>. :aI- I<:'1.----ir:::::>,I-"EE.-.»I-'-' 3. LOCATE•RECEPTACLE ON COLUMN la 1811 A.F.F. ` L..._.._.............I......_.................I......_........._..........__.....r-_...a ! »!r I I ::::II P/GPI 4 ......., Ii .! t �' ....�'•' ,.........!`.:W!._....s'<:-:::!!.........;`< '<: 8LJ-91 I . i9» i! II!,11 !I 1,11 i1 !.... I of rT� ,;::»>,! I ;r.:::::,. ....... :.::.. I" ....... ,7�„ .... 5 I._._..1'<::»!c i:»:>+I ,! i:li EF '.._Ii , r ! li :Ii I I r 8L-8.10 . 3 .1 ( .<»::Ij! ::>..I �!::>:i I ev::::,, : ..,,_.,: P EL 'H' 1 ""'" I "�, h a'1 i >?P'2 4. LOCATE RECEPTACLE AT ROOF-TOP EQUIPMENT. . 4124 !I ;. ?........ I �J 2 i!;:>1; ! f, 1< ...1..»,M ...):<::::;, _ ` na u::::»'i'12 3a Fr 30 3 t . '` !i IK I ! I. I»r1 ki...i� {._ ! ii....li I,»„ 3 I o "" '%, 2,34„. ......_.......:_....._. It" I r : r _ j :._.._.1�""" Ul ,<•...,: I,<....., I $ !!I 5. PROVIDE MUSHROOM HEAD EMERGENCY KILL PUSH BUTTON TO a ! !Ii 8 ! !.,::::.I r.::::ir; I ,) f; .h5,]7-_.::::;.,_--vx. ,<: I I - i::::,:,....:::::.._....:::::-......:::::........::::-..1...:»::.._....::::-..�...:.::.......::::-...,<,».. i° �! I!, ; (<"ic F j' e t .^" r DEACTIVATE .UPS AND'AC-10. PROVIDE PHENOLIC LABEL ABOVE d _ ..... I• :. 8n 79 a !I;;.._n r y... I:::,I..._.._J`<:::::• ,a..... 1 .`::::; �. j i 11_»>i'....,....i I ` I � . "._...^ ii,._n i 1 " �'i-<.::;.. `!!!'" .: `"!'`y'`:IV 'P'..j' SWITCH THAT READS "PUSH TO KILL POWER TO ROOM". SEE !!!! !!!!!!!� ._:::: ,!;In;v 9;::;::r J:!:!oL'J:o!1!L I!n1!:� 8L 72, I -----------•---•-•- 1/E102 FOR ADDITIONAL INFORMATION ;i!I IL_ !IL' "_. ----- •�--�s- - - - - --J- .:....F�•1u...-I-- -I- - - - - - - - - - - - - ��: r :<: ;- ; ,., I - <-f - ar:., xb', t G7i Ct Ci G�G7i �: +1 +': '•+4 AC, :: F; il<»:,n ! 1r<»::!' ...,., �' �In 4+ BFZ II+�i,, , 6'► 36 3s .. is m : ::� ' a L-i , !.<: :u! !,<:::::, :,<:::::« _7 ' .' a 6. PROVIDE SINGLE CIRCUIT PLUGMOLD EQUAL TO -WIREMOLD G20G6618. d AC-15 I H_a EF-5 MOUNT (a 1811 A.F.F. . a 8 I W GFI I . I j A 10 a1a MsP-1 I „•,,,-11.1 in 1 P° ' H 7. ROUTE CONDUCTORS DOWN POWER POLE THAT IS PROVIDED BY I 22 I a a> ) a. 'I", ti, < FURNITURE PAN ,. I ¢...t: r y.m as..: Yr," ss ant �'a s9 a9'" ( ar ' ,o...,:'•:, ' ' +a n i .:..�P --r' ..9e 9e ;h a ^:...._!ao MAKE ALL NECESSARY POWERCONNECTION.C.TO PROVIDE ALL S WIRING AND 1♦ >:,� «'� a-1,I.. I Y i ts,/j �..+o! ��, �� '� tk Cs3' �5 �i � 4 '' ? P.` �I a �\ ��I t �\�.::' POWER POLE ONLY EXTENDS TO 10' 0" A.F.F. I „" <,�l... .!,9 I ) rm:r::::. I . ... I„" < _ .. . ... . #,,L'I I ax:�.,x, „i,,,."B .,:,,.,, : ' „, ... „1 m , of I l` �, A:_, I �i j,• I j..._.tl, � F.. _1 qq-2 F j ROUTE CONDUCTORS TO FURNITURE VIA WALL. E.C.TO PROVIDE ALL R . - µ- p.Y +.qa.M.. .a4 aYS:R ` , ... " 6.. :. r-"C :: ., ».. ,. ,' ,...µ p ✓ :r a IIY -a1 nY q, �...y} .a} ` �., ..,,d.ae.. -TRACK LIGHTING f..... - L o >� «„\''' ,! ^ nt s >.J �! e 11 y % ' i t ' I } " ; as NECESSARY WIRING & MAKE ALL NECESSARY POWER CONNECTIONS AT CONTROL PANEL !` "H`! M=T .s1 ;. I ! ��al�l `� Y< ! .•v �,,I ..:;� v' I <:. j •: , !d,' 9.t, 'i��' ! .v l >v :' FURNITURE PANELS. .. r• `-PANEL'K' ,_»drr, r,,,L„»,.,»,,,.7,„1 ," , „(»„», ,.,,:»h..,:.,.:-I»„ ::,lr».... .,>, I.,,5:.,.," .. I ».1 >.,.i,j».,»"»: O N K 41 I ! i I ' 1 1 1 ! 1 1 1 ! „x, 's,... s I '»,' I I„� M,"I n L : ` ;�.. / a., mr»J S m.,,„. I , F�` ;.v;. .:.,,"-. L.... .,"'o.; .d'�. .�* M M F If.. o...x, •'`",.. a ,� I v...,, sr-�.0 .ram e] ss-' //,��t's9 sat', �nD ''�3'. ss.t.""a, i...�;, tt I..p g.. ''w..ro ._1r &7"Pa Ph �,"�..` o x j 4..ay '.(, . 9. PROVIDE GRAY POWER POLE WITH 4-DUPLEX OUTLETS .0 f ) , t o. Y r: I�. E;: ,.--- s :r......., a , . ;,? . 5: x e�t t9 '$ : 4 !`U:' ".Y°' ; •;i` •S" iC ;' ""y`'; II �$ 9 j ,.. 1 YI . . REMOTE TEST----- » ! !,,, .� _,"!„ !„„ 0. PROVIDE GROUND BUSBAR. TIE BUSBAR TO BUILDING SERVICE J„„ I„ -1,, 1 0 M 1. GFIsy RESET AND LED. .e11 a4"r .... r -i- r,,,„, ,2am... j $ ,' .� ,T 7L-1,3 7L-5,7,9 71-77,13,75 7L-17,79,21 z 7L-23,25,27 7L-29,31,33 7L-35,37,39 $ 7L-2,4 ° 7L-6,8,10 7L-12,14,76 7118,20,22 ZL8-24,26, Iz 7L-30,32.34 7L-36,38,40 f GROIUND,STRUCTURAL STEEL,AND GROUND BUSBAR IN OF - - - /� - - - - - - - - - - - - - - - -. - .- - - - -,, - - - - - - - - - - „- - - - - - - - ------- ------------- - - E ROOM VIA #6 CU CONDUCTOR. =7N -xS:- - - - - - - -.c„ - �a ;,,n- - ,,, » - - - - - I - - f,„,,,,,.,, ».�r r,,,,, »,1 .»„L•q(TYPIC. - i,,,,,,,„„- O: ITYQICAL) f I 3 I I .,..„,„.,„..., II I 1 3„ m... ry ' �"n :.'.. :� :: .rJa: .n �. 1,.... ,.,.. :file:. 4k,,,, ..., '... ,r-e: AT GROUND WIRE BACK TO PANEL a .,..._p .p.5, .. .g.. ..aa a,., : ... se.:a a /' .: I IIe.y._: .p. , r rr$ � rr r]- Pe Pa 1;.1 }» .n.y P. ,Q...7: .M saj ae 11. PROVIDE ISOLATED G OU D QX �gI \w y.>1 : cn,y ! ! r •„•'„-E r d., • •„9 r'•'�' - . 4• s j -k 1. `••`� r "' 12. LOCATE TWIST LOCK AND ISOLATED GROUND DEVICES FLUSH IN CEILING. U (� .i ! ' ! 1 I iA,. e ! »`4 I �'`,•„ I „"* »„I4 �, ' ' ,e:J'.. ^�„6,,,.,. .,,.',.. �-^. :,-k .t'h. .f.y `'., ;.'Y:, ,,,»waJ,:. d"4:.. :a' S',.. (N O . ...,� )`<._ `.. ,: ,,., _ ?. :?m+,.ao a°..a _ \. S' , ./e?.. :I ". .,p..'�_" u `C'SP sP�'` `S 7 se 3e.. e �j i to ro "+ Q1 �:, 4Z: •• •39' �• �/" 'W't' , ,, ll. , A s+-t�`, ,>;,, . 4. `>i s ;}1 .,, 3I• rI"•'P nY8 2]->\", „y, ,;!"°;;(ss so-1 .:a >x n :. ::� . !� l'`2- ir�"'•` ]a 13. DEVICES TO BE MOUNTED HORIZONTALLY IN BACK SPLASH AT 42" A.F.F fr.;�! ,; i /r: ;:> a! C.:. �.; K.c ,, t: ; * \:;,- .: ' ,,„: !o :5 Ir�1 �u cFl .._„s. 4 ,2;: :a/ "'i,r I`:i: '4:`i,. ;<:u :, ,, `;j� `::S!' .k%' `u°'I u .l < "fir w . a ,! ` '.:. ` w ''1,.,,�,„»,,,i„.t r,:,:„:„y �„J :»r,.i'" P";;,.,.,»_ "M m""; »r,,.r;,,.' ,,.»'.!»»I rr.r,rrrr, r..r.r:»y r•,,;.r,.,..' 14. LOCATE RECEPTACLE AT 6'-6" A.F.F. O m "„»e <.,„ '.! .s I I i I,,, ' "I ,»: '.,, 1• .rI :fit ,r., .�, ,,.,, N^ .- F F ! ; f* ""�:; ::?`'m.. t: :;>.* , :,'" 'y.. �, rI ""°^ ,. `P: /1Y ar.;: _ .... ,r`,. �1�,. ..d I _ ; ti; _ y._. �y.., .p Se x.. .�.✓ 0. `W: f e 1 i . 1_ r'9]. e..d , ,..� .pp.t ', ;. ..y..M .Pa..{ +, ..- a0 1: M e .r e .e..,.g : :. zo'. 1•as ss•# ./3 a;, `.]e ]e J3 "t t"_', :� �,;`f; ! O::a: :• 'yiJ �! `' Q .aco . l`'`,.. >: ,::.a: la f,:,.:a1 +,< le;.. : �...:.: I. �' �::;.;a! 1,. .<s +; ,;,5 �.. :,?� 't,:?! ^✓i "! W O �' �; : fi' :; µ; r ¢i wi fifi` y/ '" i s'; 1.' a` t 3. c' I c 15. PROVIDE GROUND BUSBAR. TIE BUSBAR TO BUILDING SERVICE GROUND O .,,� „w,L-1,3,5.,i ,,�L-7,9,11•: ggL-t9,21 ,„ ,,;,,6gL-37,33a,'},1 .,,;,ggL-2,4,6,,,,� ,y,L-14,161F,, ..rp,S5L-26,2B.4Q „ggL-38,40,„,I ,,,;,,'1.3,5,„,; :, L-7,9,11,1,, ,gL-15,27,1..`, 3S'37�" `TO 2 4'6`'" •'0 22,16.% "`"32 34 38"O" AND TO BUSBAR IN DATA CENTER ROOM VIA #6 CU CONDUCTOR �I,1 O" ^ 15,17 25,27,2� ! !37,39,41 ; 8 10,12 0,22,2d , ;�'32,34,38 42 ?71,23, 5 s 3, 1 , i a �( ! 1 !,.� r' ::3:;,: :>�.. ? ..: .:�, I. ':.�i,.�i a�>:. :,^a '.,P,,, I SL- d2. ti.i '.T"c. +. :..1 ', iG'" is '`ll: IG»; .,;� !, �; "\ ^ n V : :I ! 2?:�i II'' Lin 0 I a l '' , 3,. o` �` I e.. ? .3 h I .` « f C` "" X . . . ...).` ' 1 � Z <.>..j .s...,cT>:.PI4ALCt-r r- ~' - j .s'•< ` '"•r+ ,.- Yl pa se ,. :�_9 7 r �,5.; 'v:k ,s >h10 '>::t. sr s}w,at. .}- s .�/ Y.;�e,,u n ," \, '-as as••c. ,;`" y'•- ao 0 ) 16. PROVIDE DUCT DETECTOR AT NEW ROOFTOP AC UNIT. SEE 4/E402. �1 1--1 M 6111 ' i ! i I ` t• , t I I ! ( I AI SEE M301 FOR LOCATION. e"a " 4:-,I. az r .,,�i.: i ! {.» „�,! ! ! i u..i i,., .... I 1 (. F„I I ar ��i,d »I r :fi:„.€ :; I '<. .: ! :>?"�„! I:;.!.. ;�J' 'r<:. :•�^',! .„ r <:,7iI !,:�; .;i> I ! ,,aai; ,, !,,'��.. :Bo:�I I>'r :.;r',! �s\ t'�'L...., ' W c " 8 �\ a REMOTE TEST 17. PROVIDE DUCT DETECTOR AT NEW ROOF-TOP AC UNIT. SEE 4.E402. + y.p a- \•ao ao� w I a Y Nti .i.. � .�..�.... s, ar( (� a`i of q. oy t . KaA <�" �f mI" ��� RESET AND LED. SEE M301 FOR LOCATION I }... p,..y.... ,... z I I I i,».» I i I „: w, 1 ,. ,,,»,�, •AC-15 w,w._» 1 ( ,„„,,,, ,,,,�,» 1 i,„r., I C,.,„..., , ',:. ». �, s�',,,.,,, osi} Wy I,,,< I 9 w w t 6» _; �; 1..m .�>.i __ ;-'» .:« \I ' 1 : I;, ! 2 . ;.i j .:., E'a L......� ", i�1,J,, I W i; "I I Ac-s 18. T'STAT BY M.C.INSTALLED,WIRED,AND CONNECTED BY E.C. SEE M301 .q._.zy 5� ,i...p .„.. 4r .� yr l ...,, .ro ,9 r - ,( `� �,v r.. xae ro as .aa.... 6,',�1.._..., >: 1r' ..# 1y 1i < .... 's �.dS_le 'e .,1 ..p e..J Xt za ]a e I $ I.,: �r �. r FOR EXACT LOCATION. } � ( }¢ '„ ' ,,.,»,,, ,,,,a Y ».J,.,»,,.M.",� R»„rl,., ' ,I �"".», x I ANEL '4L' »„»»,,.,,.,",,,I .",.r.,»".,i,rr»»,C i�, i a »»»-,,,,,,,,,,,, ,.,r,»»,,,,,,,,,,,,J 7E»,,.:::. z r ! ""'""' """""' """""'' """"""`"""" '3L' „I 19. RELOCATED UNIT HEATER, RECONNECT TO EXISTING CIRCUIT. U �T 1 4L(32,34,36 I I ►� 4 F+I 3 I 4L-35,3 4L-38 1 3 20, AC EQUIPMENT PROVIDED BY OWNER. E.C.TO MAKE ALL NECESSARY : _ _ _ _ _ _ ___ _ _-_-__ CONNECTIONS. SEE M301 FOR EXACT LOCATION. - --- ,:,,,».»», » - - 5- ,}--Ef -- -I --- -- -- .�,rrl- - -------- ----- ------------ -......... .,,,.,,,,...,»»,»»ra `' 1 ` i i ! ! I I MP/CFI� j i.:: :n- ;,.,I,,; ! ry j• ,. •, r , ,;, y, -I:. 4L-33 EL r ." :"'.3, t, �;„ ;.. 21. T'STAT AND HUMIDITY SENSOR BY OWNER. INSTALLED WIRED,AND s ! /\ Y n o'Sa 7 A rag as• �~� ¢ .yY a, aI i , �'! s ' ;t I j y _a,. y,.. " �� r�I k* •ar sr ,� :' .... 30 CONNECTED BY E.C. ''row" 'C�: 1 "a'" !`, "v !/ °i 1 ''I w � I d a' ! �•` I .;v` �"£: �`b I H-1.3,5 U a' i ! '`Ie 4 -4 I r„1",„":r,,,.,.:»" r,"t» „L.,, ,»»„r<„ ., „ 1 „ r_4„»„r r, ! I I + j I I 22. MAINTAIN EXISTING POWER IN THIS AREA. , ; , L »!,» ,.k.-,.».,I ".,).», :'. x'•5.. .:,?"e. :?'a;, ''`! :'{'!'ra.. .,n• ad• �•!:,,' .,�•„ ' ,,, It. �rl :oti a ., r",..», '�,.„„.. "_,:.. rd,., • 9..f^.7 ..,/a:...o° ro t� ' �'zr rr1 �, , ».,�¢ t"r�,a ro.. ...ro ,e-�,. ' <ainl.n„ J I ,p t` t r<: ,,;;'zv sv ,,� i p g�6y ;;U9^1n ss �� ,,r.�.']o AC-7 r, a A toll! `' \� i . 1 1 u '" s \�i I ROOM ., e 23. EXIT ALARM AND ELECTRIC DOOR LATCH & HINGE BY OTHERS. E.C.TO IDF I 4 PCL "'6" �" I "I ""� ?" 'm"7 °'� ' ' 1L-391 DC-16,1S;SO' �I �"'�- J'^° " " "+. i "�"! M D5 !� CONNECT. PROVIDE ALL NECESSARY CONDUIT AND CABLES. Lu ...--I t,,.':..", ,.,»r!„r1 m ,,.6." u 2 /CFI fa"::_,a ar.:; son `�.:, ,,,•,:: sr,t;:-f r.. „�;�_ ,' Y'�,. >': _ .. .:... r", ». e... �. 's" �.so so--... ze --,.' a • ,r ss sr• 0(?22,24,2s n+ r a� „ i' r 24. PROVIDE RUBBLE TWIST-LOCK L5-20R RECEPTACLE. TYPICAL. W a fit' / i w:i U,;! ✓ .` .,: <s.'I I '3� a>' SDFZ I,. M 3,5 _. „�L-79,11,1, ,,,�„L-19272._,. ... .,33L-31,33, 3L-2,4,6,,;,�,Y .,,,r.;,33L-14,16,1,. .„v,3L-26,28<,",:,. 3L-36,3 .,»4:9L-5,7,9,,,.,,,. ._.,;;yL-tt,13,,,:!..... L-21,23 ggL-24,6<,' .,,»AL-t4,161,�.,,»: 4L-26,28, f;� � ,15,7� R! I�5,2�,2� ! !37,39,41 'B 10,72 :20,22,2x 13 ,32,34 ! 40 1$17,19 i ,29,31 810,{2 1 2,g,22,2^d. 30 -•'"" I;r i y;;i (;,.. ,p..? 25. GENERATOR BY OWNER,INSTALLED & CONNECTED BY E.C. SEE SPECIFIyy\., y{'"` .k~•..i Crr<a;1. % .i. '`.3 Kf ;. ) ;9 \....._ 0 _ IC'AL ...}. }._.Jr S q, p. p..N ; h:.. .x -i-,-, : { a....6: so- 9a __ s... ; j...µ a...l::.l Ra 96..: F y �.. z_. }.µ.. ,... xe CATIONS. ^J.,,' r 1". lq I w.." .t•., ,.•P ..b .', .,"", "�f' 'a,F' 0.,p'' ',✓ k:,I'' f d' tA` v': ",.f(TYPICAL; r�1 V : I U�J/ Iiy ! fir»'» ' 6. I „.I.J L„I„.:.. J 6'_. i »4L-U3 «„rr.„. .„„� i's,,,•rr._,,.,. , I..„»..:, ra_ j I „,J 6, .r.r",,;J �,,,r...._i ,..�. ,,..„ r ; (:.� I �. ,""I x` 26. PROVIDE PIPE BOLLARDS. :.>:: ; i.;...;; :.>.. .:.: r .. :fi:. I. Y•.' " ' r - !,. 3 .. ,. ., ac' t.. �.... rn...t,` K;..:, .k:.. L.'.... _.'.' " . .p. ,a...t,", za (az PII ,::. „ ss e•la .< se se.. ° .1 + ,, J :] n a ^/ .. y. a- tY.. >.z. M � ,1 ... 79 M. ,.... ` , `� ' : 4 <; g J') F� We .x,y. �,. g: / ✓ . ' ,s" k y ' g' JF' a,f' aq 1 �. r '' "" 127. REMOTE GENERATOR ANNUNICATOR BY OWNER,INSTALLED &rR IIpp t .a..J ,J I„m :• I .».J I»,,,. J 't»„ S .„w,.,, J �... I ..•.J w»,„r .......„.J „,„ b,.,.,1»„ I a Ac- CONNECTED BY E.C. SEE SPECIFICATIONS w 8" ,».,I .»!.zM „Y�I,'.. .,..I::<, I I.,. ry::o r,.:.' .:s.. I i:.� :x,. I ,y,,j rr.r '� L».:ix,;., ;a,w W .r,,»,.rr, i,� r^ V J SDCL !c\ :. I a- ! I 7 3 ; 5 _ >. ,. `,. !mr C i .., l, \i ,. xr )) e a-• y} z...` ,-2a ai..]o ]o.!` a ao " \ y... 9 9....k,;,a \ 1r '� __.. i'.•p Is 4 - za . IJ J, ! ';+.n` .G` '•.:`...... ''y:'' 'e`i ,� ••a,p' `�r' "� a..!" 1 n �, ?'' .�' ..f;` �' ,ia (L� yS I : J a I.> N ", .. PANEL 'D'-, :6,�::::,.:J :»„»»»,,„,„„,„ ,.,»e:,» I ,.,,..,,,,,,:' Lr»,,,L,.„...,.,,J :»:„»»,;;,,,,,,,,,,,; L::»:::»,:»„..»,:J �,,,:»»,»,,,.::,..:: '„»,»l,,„„„,,,.J` 4,»,,,»r ,,,.,,,,.,, I .:»n,-„,+;,�.I-- .»»-!.... ,.,,:»"»r' L,m»»»»,,.„„„J - ,. ! u/'� f. % ' FrGF1 g 01,4 AC-3 I I I I RI-1o.1z \...._•,,,`I SHEET LEGEND 1�Ld .L'I ,G* �I 1 UNIT 1 3 1 3 I I Alt-4 ' 3 I----1 )--1 LIGHT WEIGHT HT DASED LINES INDICATE LG EG ,_` GF,��rcF1 LLi ; �`i t ---- EXISTING EQUIPMENT TO REMAIN. �,J„� {� .7'd.2,461 -'- - --- - - - - - - --- - - - --- - - - --- _-_------ - - --- --1 --'--- - - -• -- - --- - - - ---•-----'-- -- - _--------------.--- ------_.-i..-,,;.,�..:--u•- --»rx„:9_-_-,I;,.r..rr.,. „ » ,,: » .,. .. ,»»r.rr..�..,,� ., .. » .., � T sa M-S,tO, Tf-.....,y �� O i »..r»„ r, - W 1 t-, 1 I" ""i I I i I I 1 II l 11' �t HEAVY WEIGHT SOLID LINES INDICATE -f„ i �i I , I 1 ell I h41;, :� fS.. ,:a<:, 1 s....,,;•. q .C:. ..,�'\� ,`'a�,. .a'3\\ gr+, I I{ 1. +. 1� j'!':.J ',;.\ ..r'.. S'c„ �':v..'... ',, IL-41 ell }....t. o W.t, /' .- ss.'. I � / .1.ro- .a t ��j ao m9 k .,.e.. m.. J. j p�u.,... /::.. '-: � .. �° °°. �t a°_I° ,y NEW EQUIPMENT. Fi I .7, ':a' !�uj .. °'ti"._. � '"Y�i' ,I I :G' '�Y•'`'i ! x ,» 8-...tt,::..:>" ! !1 _ I 2 r i v.m,,... 1 J'i r.,,y„s' I' a,,, , r.,i,,.,,..r. >s3"^ 'aa' p»ir,.. .»r:.,J,,..1 .,,J. 1 ....L'. 1 �~ I I.. " y I »"J:,: ,»,, 1 ;A:_»rR » r_„:»1 ., :,»„c„ 7 ;„" t a, ',I AC-6 1�1 : I f O-�R ;•, ,L '. tea::. r":::. .�•:. ,:i•,., r ,.,r».:,,r :., », , .�., ,' x(.; h*. •I ;d t., »,,, � y •"" t , T... � .'. ... t..s ss.. .....sy.$`C .J, r. a € a. �..t k" r m ".1,: e.. .y. fi,. .14, n. �7 Y.. ss•i'..� o h e„ ..e.�1 � .r...p ...�. � .�1{s Pe *p �� S-•se]°-*.%'.,S �p� _ rn"R1-it 1 ., C. F. .,3 �,, .:> s,1 1\,..,.? ,fJ ;, �<.!' 1� 1s,:'% ..,$ .,j: .9 ...yO.,' a�i �. ".:;/; <.%" v,5a! .; ; :/,•? .:. �i4'�.9Fr 1�1 �I ,,,;< / yam'\a. 1 ; 1 GFI'. WE SF »i :P:' ,rrma„„ r.,,,,.,.,,, »" <,„ .....�. t,» , 1 I»,1 t 1.,,:»»» fir,,, I „„-:»1 �.,' ::t a r F,„ �r IL_ i uj Lo r I r i I:,,I J,,, I I-r < H4. , '"t :0. +•C r "k HWun ..r`" :Y� „0•,. p� F ,fish :f",� „J. {: I .•�,:'... : 1 0 r .....M tt 1` ?' .y F r' 4:. -6 l<, ,.. .I: ;i `R. ...7,^" "a,�... '+,.... �, fi` TY~/GFI e ''' .r. II.. n/ a}^ a `,. µ '✓„{'Pa - "'y-1.. •••r ] .",I ,. ..e.{` ! • 16 r.za 9a.'' ]e. .,1 n n,"„ .e• '. a! a :, y? .,.o! �. r ! i n h I, n1 1. :,�., ` 1' � r� f'- i� /�/'� y Q W \`G'' \1;:'! 1 .:✓ <x' ' !.lJi. a'.. ,fi. u ,�4' .�,. .1?1 • I.. I ; ,/ a`'j s y� !' c:r.:z;..rc?,crr.:i ., .w: .,; ,::: % p a p p _.•,»1L-5,7.9«,_ I,��LL-tt.13.1�,1 .. r��LL-2t23,� .,b,77LL-3133,3.�.r_ .. .,�L-2,4.8..,,,,.", ...:_�:�L-1418.1�1 "a, -2628 .::,,fl1.3.5.1w".,; .ar,29213z23'1,„ ..r'37335'SSmi9. ....i.,870.4.8... ..»�„L-2702.14,1,�: !'26.28�30""; .36,38.40` �,,,.'.....e ...-..__..,tr,17 17,19 27,2� 37,3� !B 10,12 20,2�,24 2,34,36`! .`:. .(,. /��� �\ / I;,: p... IT: II.AL),�...., 1r..�,�:b �'.. `...f sr.'�f F.. `1... sF.. ._..f`y? �. ,t.so zo,, „ ;a.}ss a? `�a°r rt" <£^\�,•-,14 s ss ss a P. .s- ,II tC� •••sx as -'TYPICAL) :::.�i - I EF - fit' ,/ ,'�'' ''aar 'Y,- `aqr `ash '1/ .aj: „1y. `p k' �,d" •'wy ''� ,.I.. '";I,� '' ai" 'a •a,' 1 �Iyy0 \Ji A'I• „J ,.nri J ..._., (^!wt i »:,».,,,i 4!,„r.r.r.r„r..•! I .,.J T�»w4 a, G.,,w.r.r...-, 6».,r»... „,J L. 4,r»»»»r„w IIi �JI. i_.I •J 1,p,,, !,,. '„,. ,.„'r» ' ,,.»i t i !,,, »,.rr.r. ',,. r I ! rz.1 .. ': I r aa1 A m ° $ /� •3!W„I .�. sue. I "'�,r », igl r„ I . P...J" Yl ! '' i"• }.P9 P4 : -n9 3L.la, ,: ..g g.. §. < 4 PP „3. aa...::: \\ ..a.. ..a..&. 4' le.-M'Y .,"!"'P} P9-ae 3, W...,... .a.., `�S.-p 'P,. P,..i�,,y`1. < d'' r1II I� IJI \ ''y<' !I "\.p........ {.. ,F' 'aP -='p.ff__�r+____ -P___0.,a_____��'___v�'_ __�3__-y_- - �y.F__-v.(__ __ ___i�_____S.�__ _ __...I'' :' .....J' . -L, I ' 1 1R11- --r ------�'; r====`___�__=--- ---------- -- -----------------------°._ ___=__ -. n,»,,,,,,.,..,J• .,.,.,..:»„-_ .,.,,4.6 i6:: <,-' EF i "�' a,»I:, !.,\ ! »„ s j-- j �, !: «.1 '! ».»»:, '1v„I ���� .,J SS ss3 1 CI • • I[ g I p..y," ;;'a �":,� t'9s P4 O"rxmFrrn.rY ' R."t,. p..A, f''"/) -Q I (.I.ri I„JJ - L I e• s I f' i F g¢ � H C,7��7`p" R2-7 I „,.,.i G,..»r.,,",,,.,,,,.,,i 4 „d {�»».».„ I l!.,s �„si �'� ��i.- p75TEReO -----__._. -_.a__-_.___-_-_____._.___._-_-_-_.__-__-_ I--_.-_--_._-_._-_._ _ _ _ _ _ _ - _ _ _-_--_ _-- -_ _ _ _ _ _ _ _ q IP ro .3 G :,\,.;i ,-REMOTE TEST I O, J 2 j h (� rw; f• } T� r RESET AND LED. / ` ' I r, 1 y ..y I O(D iLjIII �. ' ........_...... ! .i.... - A f 38 I e d:�:.!" I rp IIIsi T �r m„"„,» - - - - - - - - --- - - - - - --- - - T `- ___ - - --- - -� -•[-'..:-- ! ; . �,„ - - - - - - -a F I---- -----------------•-O 4N R B n . I ........" i' :; r .1 ! ,,r`!_p° za1 ,. sr;'I, !i.....1 !:.._.:: I \ j::::_jj 8 z$`'' I "t' z1 Rt- . - 1 - - - - - - - - ' - - - - - - - - I- - - - - - - - - - - - - - - ----- - --------- - - --- - -- - - - ---- ----------------- n.{i - _� 7 rr�'i,......f" F,.:-' .....;P....::a'.T"1 ::: :F^...£_ L...... R7- 1 r ,�'� a 1.1...11 f..:l.....' ::IE:::::,:».;�"'.9:::...,_ ,".....,.,, .1. A..... t '19,21 .... ` { j ,, R2-17.19,21 ) u-:jy-dI 6 ...'Al- �(' EF e I::::s 2-1! 6::::::... 4 V i ) ""t.,.._..,... i" ...._ _-- _ -__ -_- _ _ _ _. --- -o I �( r � I I ......t1 <.... ... r' i:."°_#1....,.._. ».,r,.rr,„»r„,„:ti. DRAW N CHECKED j J .».» »» LL !' ' I II ......�iL-41 ,-....' ! ! KBB t3LW ,_::::::e 4:.......:. . . ,i 4 ..... a �i �- I R2-3 I 11I I - O - --- - - - - - - DATE S I J ,l IIa..' n \n '` -----•---_----1 M 1o/DI/o1 I R2-41 j jI P cF cri P I _ - \ 2 R2-35,37,39 I -O SHEET TITLE ►$g I- R2-42 IVIE, i �I ,* I I R2-421,'� 9 - - - - - - - - - - - - - - - - - - - - - - - ----=r---------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --0 POWER I . I I I I PLAN ., I .I i I POWER PLAN .. I I I I I E301 SCALE:VI;' -T-O" SHEET r I I I I . 1 0 � � � ° , � �- . . .. �01 . F . m , . ' . .. NORTH 1' e� o �22 N L61 LLOy LLaN' 2 3 11 13 ¢~U 00 11 2 3 4 10 a �Uz �N� O <Lu �z� PANEL 'SB'PANEL ---- C.J MAIN SWITCH PANEL-r __- EXISTING 30/KW , PU L BOX' - iECR-24* 11 'MSP'. P EL '6L'-- SWTCHGENERATTOO BE REMOVED. REVISIONS 1 A P EL '7L' -- SEE 1/E102. -y' (c.a.ir PANEL 'DP3'------- �� __Xoe ® ® ® ® C ANEL 'LPT--r� ii-7f \Gui; ._ Sr O _- TRAN F R - - S O MER r a . . SEE /E302 '�+PANEL 'M' i 2-12 �� FOR WORK IN THIS ® ® J T3 �1a R2-16 1 EA. i� --PANEL OPT D2 2-14 ; pN r` '. _ I �I PANEL 'ECR'-- 0 — Li o � xs D3 3 EF-6 ti R _ Jlwvrt;ct R2-16 - Q v', -TRANSF RMER D4 L-42A PANEL 'DP2'--- �' 2_7 sy " ' 'Ti' rr+r+rr+r r R7-23,25 �_r=a _ 1111 HILL AC-5I PANEL 'R1-. TRANSFORMER - i -REMOTE TEST -- 72' i RESET . LED -B 3... PANEL 'R2' -----! CONTACTOR --------� .� PANEL 'LP2------------1 POWER PLAN 2 POWER PLAN r,_1POWER PLAN E302 (FRONT MEZZANNE) SCALE:/e" - 1'-0" E302 REAR MEZZANNE) SCALE:/a' - 1'-0" E302 (REAR MEZZANNE) SCALE:%g" 1'-0" `J� E `ir 4 GENERAL NOTES 1. SEE SPECIFICATOINS AND SCHEDULES FOR ADDITIONAL INFORMATION/ o m REQUIREMENTS. n/ � © M 2. SEE PANEL SCHEDULES (SHEET E103) AND RISER DIAGRAM (SEE 1/E102) w m FOR CONDUCTOR SIZES. r co .f R2-2 3. E.C.IS RESPONSIBLE FOR SIZING ALL BRANCH CIRCUIT AND FEEDER O o CONDUITS.Lit I m 1 W © I MIRU 'S C t t t t "tiRz-z 2 SHEET WORK NOTES O w © PANEL ECR is rRz s „•, 1. REMOVE COAT RACKS AS REQUIRED TO ACCOMODATE PANELBOARD ECR- 5,27 N INSTALLATIONS. ' r i PANEL 'iLL N M-2O2,2 2. ROUTE CONDUCTORS TO FURNITURE VIA WALL. E.C.TO PROVIDE ALLNECESSARY WIRING & MAKE ALL NECESSARY POWER CONNECTIONS AT /'/'� ��--( Z Ec FURNITURE PANELS. CE, �"'�-( Ln O 'y R2-6 Id` �H _ 3. RECONNECT EXISTING DEVICES TO NEW CIRCUIT INDICATED. DEVICES `�a ARE CURRENTLY FED VIA CIRCUIT IN OLD PANEL 'CF2' SHEET LEGEND :---n' LIGHT WEIGHT DASED LINES INDICATE I�i Iy ---- EXISTING EQUIPMENT TO REMAIN. 7 HEAVY WEIGHT SOLID LINES INDICATE r� NEW EQUIPMENT. �1POWER PLAN U / E302 (FRONT MEZZANNE) SCALE:I/8' • T-O" [✓( I..0 O U � V � Z U j H V w � Q � U • pil 4 8085 s,11lo1.� q '>f OF C+ �qN R gFl(� GTA JOB NO. hL DELLGC DRAWN GHEGKED s KBB BLW 2 DATE 10/31/01 SHEET TITLE POWER PLANS (MEZZANINE) SHEET d . 302 2 .(4) 1 o 1.1 1 2 1 9 1 4 I I j I I I i i i i o tj�2 �:s Vxl fEztenor Lu I I �hone P j Q (L ,a tZ-- ------ . . �l C:� Cl J C 4 V C7 i ......... QQ ! I I I ! FOR DC & UPS cue W w Z Z j p s SYSTEMS (, PREACTION PREACTION y p Y/ ' X5 01 V/ i I I I I 2 1 OVERRIDE PANEL SWITCH 1 Vx 3s '�` >' `S .•.� K�^(<'�i QEYIrJI�NCJ' I I IL i PREACT,q ,/� `� Oxl Dz2'. 0%`i.:.>!ON OVERRI E h CI"4^ �Y' `�(l i ... 5 I SWITCH�'�:r�r' 01 e ;!I M • sq asap. :::e t 1. I Q - I I I I i.._.r r' r !! i Ox :� Ox21 Dx2CALl Dx ✓ 2 ! IT I I ! »:,•� 1.... i:� 1, ' .:>.i....... �,� Vxl fExtenor Phom) S 48 2 :::::>:! as D% 1!Dx2ll:. V Ig <::: <:;n, :,.<::::!� ..... ---...�•<:'::"r' I Dx ! Dx2! "Dx Vx2 a- ISM 'i Dx !n 10 2f1 ''i' ral ;; i -- vi:,,,>,f L:>i� @::::>�: I :,::,Dx :Ox Dx2 /: !�\ G,:, :::n .........i L......_; 'i I.<::::u, !T�' ON .a' ,, ; ir.<: i, rJ.' ,y\(S',.,,�V`�} �✓gyp [},>:: I ')..... :a•7 Dx ni'Da12!i — — — — --- —f— -- - ---•—'------- --- — — — — �� n IL....ri 1.....:!!limn 1,1'::::,�::::::, ,,:..1 1;.....; ,<...a f. ly'.... 0x i;D% :. ,.,, I ' . ,�<:::::r _ _ .....;,<:.... )! ';�;e':,,>_ ":>11 D%;;....>ibxzj .. , x .. t- �..-. x oarl±:..� :ox2. :. Dx ,;,o rt_ 1 Dx ,:" _ �- - J - 7� i:I,. n, N � n ! I I 12`':.,!�''i5p61f' � "� — — — . ii: ox�plr" 'D*2 G l 5 Dxl u1::::,.a j !U ! it ON ill, is Dx2!1....,!0%''! 1 , I / 1,: ,i I Pones Vx2 fl 1 1<,»,( !<::::it ......Y w v::! I ! „!U ut::>iI Dxj}+I'...,u Ox2:I:::: Ox2; SpMI, I............... I ....._.A.._..._,'<:::::a OxY<:::::. Dx2 L,�h!0*?<::a.!i�2.<:,:ic i'Ox _ ......� L.@. } t....... :>''L......' I i „»,.i, or ................._....................___..._.._._...__..._......__.........._ , vi E 1.J...._ ...... :<:::::U Dx2 Ox ... ,�i<:::::c I ,r. ...'� ,y r •� h ! 1 Sg PN ":....� Dx2Qi;:::,jj Ox2:::,rr<•:,,'::. :c....,, - ,•�.. r' - - - - - - - - - - -o*a! i�m<rD**R,-; px :°�:o*a<-: ," - - JAL - - - - - - -a- - - - - - - ` '! Dx2 'Vx2-fl• - -ttm:::.r•j1 .,r 1-1- - y�/�/� /� 1 36 36 0ir21 it f'i j Dx <::rz V i D%2::::1', : D% .: n,o. O%I 36 38 O%21if li Ox,$ inx2 i i V lJ V L J Y!::::r.i pia: r 3g EXISTINGEX EXIT 1 9 5 I I 5 Dx2 Ox 1 : , Dx ARM ! 2! 0,12»Dz< b�.. a i.,, § �. ••••t �. „s•., ,.�. .-»Ox4 Ox »Ox2'I Dx2 Dx2' I Dz4.`•• Dx ON� Dx2' Dx2 ' D� �. r,,'�. N'•,:�' i � t5,. .d� ��' f' ,r,-I' t',� l.'��'.... � q,r DtF*, _ _ y Ox Ox2i .' .. ,. Oxg ! Dx2 ! i I Dx Dx2! i Dx Ox2 !D'2 ONO ! ON Dx2! •,,Dx2 x2 Dx ,I �• , ..!�' Vxl - . .• +^•u 4 r0 :t.. „�. , IL'Ox1'"' •,Ox._.Ox?'i. Dx Oz2 +Dx2-.0*Z! Ox ....... _,......._.: .r� k ON I of <. . y, �I0.1 p ,: .._�' Dx2 1 0% Dx2: I ON ox %2i 1 ON Ox2 5 Ox2: O>j2 0%2 ON Dx2 px d O m .d''+:., :ye ,dam +ri:: •.<� a^*; .�.. ,.. x2' Ox2 Dx?, Dx Dx2 ,.Dx ON! D K ` I Dx I Dx2: Dx D co xfbr,- — --- ---- --- — I — —•— —•— — #»-1'— — -:.Q — — — l — — — — — - — — — — — 1--1-� �O »Dx2 Ox 0x2I 1"Dx Dx2' Ox Dx2` I� I "4 ,,:� - W,. M r` —-—-—-— E N O t 1 Dr12 Ox' ...... L. �y� ^.. p 6.. d Zb 0" DxZ D%q 1; Dx2!. Ox Ox Dx2 06 p*2 Dx" xq p.., I:. O Ox 2 1.,..: Dx2 t ...t.,. �........_ e.. c: IL__;• �'h K a !.':. s'.' )..x 0✓"` `':y....... .y , ✓ ov �; w' /• o.. %is s. 1 :i .: i..... ? ti X I I r r' w ... .._..... f ' ' �;' i ' .;. ..: 'I SHEET W 0 j' D 0 . Ox2 ! C Dx Dr12 x` I ,.::. r,.! ' — .. �:.. Ox Dx2! ;Dx 0x2 Ox2 0 Dz px2i !Dx2 Ox2! ,»Dx2 Dz��Ox2! EXISTING EXIT k<:: ,..•}. a ^ �.. I 1 Dx2 Ox2;, Ox ON „Dx2...Ox2' ..DxZ Ox....Dx2 O* ONO 1 ON ! ALARMROUGH-IN. I LL _r ............. ?' ............. h.. .>"�............._. �•. ::.._._ _._✓ �; �,. 1 a 0 1. CARD READER PROVIDE 4" SQUARE BOX o 42" A.F.F..:: r,, c:::, .::.:,: F;. ? ..r. ... . - . ;tag}. t �..._...! o .w f,.:: ... ... i €;, ...... r: ... o. ..n _......_ > :: " CONDUIT W/ PULLSTRING INTO i a . , x e.. :: ": c yi ;.: ... 1� i �; ;1 ... . n, �4 0 NEAREST ACCESSIBLE CEILING SPACE. of ,m.:;,», •<,., I ! �< '" '�' may, 1,.7 3 ru 1 Dx N2! .Ox Ox7 Dz Ox2'. 1 D'2 Dza �„Dx D%2 - ! r r _ _K1J O* 2. SECURITY s.�, oxz Oxr ox Dx' �D' Dx21 Ox oxr Dx Dx2' oxz Dx Dx o%2 Ox ox' D% Tox2 ! CAMERA ROUGH-IN. PROVIDE 4" SQUARE BOX Ia 10' 0" A.F.F. d'-, M " :>' ..............✓ ""+,..............✓'.,� :..........._. 'a''O ;.'i" a O., .y 1. ;:.y, rr..TM. .n:14:, r', {„ -:_ _.......... .............. . r I c;Dx M\ ; ! r - - a STU %q" CONDUIT W/ PULLSTRING INTO NEAREST ACCESSIBLE CEILING SPACE. N �. , : »,> » " 7 VOICE/DATA CABLING TO BE ROUTED DOWN POWER POLES. POWER PO >N r x. LES y, 3 O ...._.�. :,,. ,::. ,'�.........._ � �.. �.._._....... �? �. ............. �_L. ,,� ..... !r;:E .! y, ARE PROVIDED BY FURNITURE SUPPLIER. f ck' .r> Y, ip a.r• a� '+�,,. „ �s jai' er t" '.s;a r ��a.�" ,rii�' 'v.,' --' ,,,E. ..>ti�`;i.4......._ 3 L i Ox2 Ox Dx2' 1 Dx Ox2i Ox Ox21 D>♦2 Ox2 px Dx2' Dx Ox21 0* i r `� _.. V Z .... ... ., i 1, J 0%2 Dx2 Ox Dx21 Dx2 Ox2 i px Dx Ox DxZ` ON; Dx Ox PROVIDE GRAY POWER POLE FOR ROUTING VOICE/DATA CABLING. O p »� 4 , »:� »:� c„ v<n � L :u �:. .. ........ ��.}: �: ,. �,Q... �<»I "�� :>3<. , ,, :r:.I .....I,::a� Y 6:.I r , " ¢, y .t I � ........... .......__i i 5. PROVIDE ROUGH-INS FOR INDICATED VOICE & DATA VIA WALL. „G _ _.. ..... Ox7 $Ox Dx2: aj2 Dx2 �t`` :, -� J ! ;Ox Dx2! m� Ox2 ON; Dx21 Dx2 Dx2; D I x2 0 D DN. 1 x. g D� rl"o '•j"x i�"" "'"•"•'" •' o-� •'i ,^#'•-:' LOCATE CONNECTIONS AT 48" A.F.F. Dx Ox? !! ,. r � 1 i ! Ox2 x Oz Ox`I � � "�' � gf: 1 77. PROVIDE ROUGH INS FOR INDICATED VOICE & DATA VIA WALL. Dx2 I Ox Dx2' Dxq p� ' Li Oxq 2 Dx2 Dx Dx2j Dx Ox30ON; px2 p i � �( ,.,,,.,.,, „..,,.,,a I„w,,,l»,,,,.,,,,,,r .,..,.<.,,,,,,.,,,,..,,, «. ,.», I 1 Oxq ; Dx�' Ox Ox��< w DN....Oxa D.2 , 5 j j U ---- ----,, -- --- - - - -.- - - - - - - - - --- - - --------- - --------- - - - Qtt M,,,,.,:. ...L::»». ;,,,,, ,» SHEET LEGEND ON, ox2: a ox2! Dx Dx' t�o 0,02 1.4 0.4 oxz .�" —•—-— " : z < „ s- I I:,,Ox, Ox2 (Olx Ox2! Ox2 D%27 ON --- r" *.>., :> 9..._.._. '.,+ ;' a LIGHT WEIGHT DASED LINES INDICATE 1 I Vxl Vxl y i* l•*k _._.: 1 Dxl 1 off G EQUIPMENT TO REMAIN. r......... EXISTING r -Dx2A Y Ox Ox2,, Ox Ox3� X1 0x 0x 0jr Dx2 Ox DXZ 1 Dx, 1°1 j 5 ! ' i SOLID LINES INDICATE V 6 Dx2�t Dx Dx2j '11 Ox2: Dx2 p%2 px ! Y WEIGHT ry , HEAVY NEW 1 �: „1I D - DATA DROP/DEVICE VICE Ox2 ! Dx Dx2 1 Ox Ox2 ! Ox Dx2, 0 Dx2` i Ox• 0x2! {.._ t �c h,, »i E D ae. r. ! Dx Dx2! + I - " r 1;.. 4•e ; D• l Ox4 Dx2', Ox p* Dx Dx2! Ox2 Ox21 1»0x q)1 ! ^^'' ,, : v ! V VOICE DROP/DEVICES I.i. i:, \ - .........._ ''':.1............:. "� P x - NUMBER OF DROPS/DEVICES W , � 'd''I . ..i., •. .> (I.E Vx2 2 VOICES DROPS). , ; , 'I i I Dx2! Dx Ox ON; Dx2 (D Ox ! 0{r Dx Ox �r } ... ;Dx2 � DI% ! »O* xZ i Ox2 i x2�r' '~t' Dx2'' a' 2c�F�' 4.1 p a a>Ox %„i� L„0 x2 GENERAL NOTE „ r,a D 0 x ; Ox x2. i �D I ` v y,r. :.: ) I , i ✓ ,f '1 , ice ,. �a r ": { .r�—.1......_.t:. .......1: ,.' �: .5..............L ,1..............t.` 'Y' ... .r...,i'....... Dx20% 0x0% ° '' �` " �" °? °�' "� > 7 � D%1 1. VOICE/DATA CABLING INSTALLATION AND ASSOCIATED CONNECTIONS BY „r• �Dx� Ox Ox2 `D� Ox2 s Dx Dx2( Dx Ox a Ox2 Ox2Ox� Dx2I t Ox Dx2 I Dx2 # Ox Dx2"' g par Dx2 Dz2 D%2"' I Dx NECESSARY ROUGH-INS. O ox2: a J OTHERS. E.C.TO PROVIDE NECES W a [x2',!' ! Dx Ox2 #Ox4 � J it""•1• D% 0 OxZ Dx Ox2,': ; Ox Dx2 I Dx2 Ox2' !0 Ox2! ! Dx Dx2! 1 Oz Dx2ly 1 Oxq 1 �'•Ox4e !0x2 Dx7•i0.2 . 1 ... :»:,:,d:,::,.., ' ::»»,» ,.,,:,,: t ,» t,.»:»,1:,,:..,, .,,»»» Ox1 Oxl i Dx1"'< 0<l i t Dxl Ox1 5 Oxl ~J w a lixl I p%I — — — — — — — — — — — — — — — — —,... — — — - �.:,»,- — --i„ — — --- �,,,- --- --- — --- --6F- ----- — -,.-.--•— — — — — — — — — — ---•— — --- ---•--------- — — — — — , Ox Oz2 2 Dx ; I �S 0 Ox 2i ,0 x 2 D e x2! „ ; �''�i%I Dx� x p r\� `.�"i�I '•�Y :"�x 04! Ox Oxa Ox Ox2 1 ON: Ox21 DY, Oz Dx2 !0x2 Dx2 i "t 2 n, ,?•�.. .;;,;. tee., .,•i 2�.R Dx Dxt, ;rI Dx Dx2; Dx2 Ox ON px2:' 0.2 ......r;: ......_......,> r D. *.ads,.. ! O Dx 0) _r . ....�" 1, ,:Y....... ;.�', ��,_ i ' , i , ; �`"I :�✓i'' ��,� ;k ,'I I+, �r u rr s " kr .a:91 O W .. Dx2; ! Ox Ox2 Ox Dx2 Dx 1 Dx Ox2! Ox2 Ox2 ;5, ') F,r Ox2, Dx2' Dx Ox2 O�r Ox2 Dx Dx7 I Qx Ox2' v,O px2, Ph )ie o rr'+: .r"i; :rv: .y a`�*.`Ox Dx7s.t .•b.Dx Dx2 x2 r Vxl fEx one Lo .: .. m a r ,: low: 0II ` y t „ ' ,1 �,.. I , , V _ +` .............. :� r::,. ,x.....-.._.._z. � ._........... ,�.. K ��,�?;, «�nl �I !»•�,. .,fi. /•. ., . i N11 !I �i Dx2 Ox 0%2 Dx ON Dx Ox2i Ox Dx2 Oz Dx2 Ox2 Dx 1 D�r DxZ"` `Ox Dx2 dx Dx2 p m m, •,s wd Ox J E»I : -I,,,, ..,J y� D%2I 0%2 0.2 Yv Dx2I I Dx Dx2 %2 a q 1 i.•J a: < I x, ; pr ��f � � ... I. ...{, 4:.' '"'- ,�" - - Dx2 D%1 1 0x Ox2 i Dx Dx2 0E %2 f Dx Dx2'" ?p : J f PDx Ox2� Ox Oz21J4 {.I Ox ..Dx2 ~` x2 Ox �b Ok I» . .m» : J ox Ox2 ` Ox2 x OXIIDxl Dxl w „ "."..,,. G».»„ Dx2 a I j!.:. ! a Oxl,,, 1 Oxl I Dx1 M : ;i.._... ° I D irlD 1 n , ; , z,r i 1 Dx2 Ox Ox2 a Dxq 01 Dx2; T'i —•---•--- ---4-1w--'---_-OuL---------------- 1DY----- D'L-------- — — — — — — FF.S ST -,r,,,,,- L� — — — — —Vx2 D-Byp e a , — — — — — — — —-----------,—•--- gg' Dx3 _.._f I 1 I Ox2 Ox2 r gx O ,� 58085 � . 38 J I Dxl J � V P 1 I , au, ,. � � <Pj ll�/o l� Dx2 Ox2 I ��,x 9��rF of 4 ........ .::c::. — — — — — — — — — — — — — — — ------ Owl - - - - - - - - - -sy�t[` - - - - - - - - - - ----------- 5 - - - - � � oxz .�..... _ II _ _ : ,.:...... � �...._. Ox2 Dx2I {v � 0 2 A JOB NO .,s t 1 +i 1 tn, ti. E j µ; CT t _.... (...... . . wp ,< ,......., Oxl 2•::3¢:-'T:..... 5 ---- -•,..,.,,.,, O O 'J I—. ^' DELLCC I L — — — — — — — — — — -—- ---•----- 3 i Ox1r :......... .. t:..... Vx2 f1-ISGM xl — — — — RAW EGK L" D N CH ED Ozl I I Owl xl Q KP.B SL!>! —- I'I 1 DATE 5 Vx ( xteno.Phone) EyRISST�NG EXIT -------------- \ �J 10/31/01 I i , 2 i I - - - - - - SHEET TITLE i i 5 i O —•—_—.—_—.—_—_—_—.__—.—_—_—_—__.__-- 2 ---•�------•-----•-•-�---•-•-•- ---- - - i--•-•--- - --- I ---•-----•---------------------------------•-•---•----,--------•-------•------� SPECIAL SYSTEMS PLAN I 1 I i i i ��SPECIAL SYSTEMS PLAN SHEET � o � 1 (r,l Eao) SCALE:!I/5"..t,_O„ .. 401 �. NORTH i o ul)� Ww W I- 2 3 11 13 11 2 3 4 10 '� U=V o • o CeW w c, Q gym= - � A REVISIONS s . ❑ s o O _ Owl D ® ® 0>,<2 Ox2 -0.2 I ❑ 8 `J j D - , SPECIAL SYSTEMS PLAN 2 SPECIAL SYSTEMS PLAN 3 SPECIAL SYSTEMS PLAN E402 SCALE:''/e"-T-0" E402 SCALE:''/8'•.1'-011 E402 - SCALE:%8" . P-0" F+1 0o M W IT Ii1�0 SHEET WORK NOTES: 0 N 1. CARD READER ROUGH-IN. PROVIDE 4" SQUARE BOX ® 4211 A.F.F.& STUB�/ w m 74" CONDUIT W/ PULLSTRING INTO NEAREST ACCESSIBLE CEILING SPACE. -'-' RELOCATE SEE SHEET E401 D8004 TRANSFORMER ENCLOSURE D1255 REMOTE ANNUNCIATOR— 2. PROVIDE ROUGH-INS FOR INDICATED VOICE & DATA VIA WALL. o ----"--- 3. PROVIDE CONNECTIONS FOR INDICATED VOICE & DATA VIA WALL. 120 VAC -60Hz DEDICATED CIRCUIT i l I i ______� ALPHA III FROM POWER DISTRIBUTION PANEL ____________1___J 1 ANNUNCIATOR L__JI O co L_______J 11 ' ,'I, L______------1 Q� ------------- ZONE "BELL MODULE CIRCUIT SUPPLY-�� D8109 FIRE ENCLOSURE--,. li�� M'� A VUJI RELOCATE ( <-------------------------�--IJL—� I;'1 ��� SHEET LEGEND , 1 Z "------------------- --J I ----SHIELDED CABLE 0_4 SEE SHEET E401 : I•=____________________�- ' I'I' �N M EXTERIOR & INTERIOR 1 'I I, HORN/STROBE ' ' `U) W.-�' , 'I.' �---'� LIGHT WEIGHT DASED LINES INDICATE Il.�l�1®rll�.s �y_�r=�'=�''_ e-O. Ll+} , r'} „p 'J ' .�--r-----`---- e{ ZONE 9: WATER FLOW SWITCH - EXISTING EQUIPMENT TO REMAIN. 'I 7 �N— I 19W I ' ' --L----►---- SPRINKLER RISER W _f1_L„1 , , >, I D7L1LD I;=S�--F ' HEAVY WEIGHT SOLID LINES INDICATE ZONE 2: CONTROL VALVE , 'IJ' 1 1 e)I' I' SrT=J SUPERVISORY SWITCHES - I 'IJ'11 I�Lq,lii CONTROL/COMMUNICATOR ihlii I�ryb ==r----•----}} ZONE 10: MANUAL FIRE ALARM PULL STATION - NEW EQUIPMENT. ON OS&Y VALVES ON I _ �__ L----4---iW RELOCATE. SEE E401 BACKFLOW PREVENTER �' ' ��`_ _ ;..',�' ' ___ 'lll'' =� D - DATA DROP/DEVICE I Nl�l'n)1A 5n 9•)`u�5a) `»wTil�2d� , li ry{y__r _ ZONE 11: END-OF-LINE POWER V - VOICE DROP/DEVICES JLL_ �_ZJ_ _ _______J'____J'll I I 1 y.__L------r SUPERVISORY MODULE J nn , , ,1:— JJII gel +•+IW x - NUMBER OF DROPS/DEVICES U `'!' II---� 11 , I,Im01 I IT-fie. +.+—L.I PER AREA. ZONE 29: CONTROL VALVE I I n I ' Ih 1"' - I I � � ZONE 12: SMOKE DETECTOR - SUPERVISORY SWITCHES - � I !I „ ,� „IIIg i- ii;rM2 __r--���----FF � --- FIRE tW FIRE ALARM CONTROL PANEL (I.E.VX2 - 2 VOICES DROPS). FOR DC III UPS ROOMS r------- i II li :, iil,1 , ' ,' *j 4 ' 1' I: 'I "'i`� I h i1 rya?--r----�•----21 ZONE 13: DUCT SMOKE DETECTOR ILtt, AC-1 MAIN SALES AREA PRIMARY •T�I-• =_L_I , 1,-_ L_________J___ ,�_iaJ__� PHONE LINE.ouP'Ir' 'r' r�I I 'I' 33 y ' , '' ,rr=J U 143L__r-----•---- g ZONE 14: DUCT SMOKE DETECTOR - I ' ---L____L___-w AC-2 MAIN SALES AREA 12 VDC 7AH I I T= GENERAL NOTES: w SECONDARY 'T-��Ir! '_y______ 1_ly J''I I BATTERY I I q5_ --• ZONE 15: DUCT SMOKE DETECTORS -z__r 1. VOICE/DATA CABLING INSTALLATION AND ASSOCIATED CONNECTIONS BY PHONE LINEr-------rl �J I' ' 1 { �"-L____L____ AC-3 MAIN SALES AREA (� I , 8-- OTHERS. E.C.TO PROVIDE NECESSARY ROUGH-INS. L_____Sc______ _______J _J I:ryb�__r----�'----}}gg ZONE 16: DUCT SMOKE DETECTOR - {3 AC-4 MAIN SALES AREA SYSTEM CONNECTED TO d T.J GENERATOR. RESIZE '' ryT•�--r----�'--- ZONE 17: DUCT SMOKE DETECTOR - AC-5 EMPLOYEE BREAK ROOM BATTERY AS REOUIRED a' TO NEW PANELS r--�, - f/-�, D8127U POPIT MODULE 8 `H ZONE 18:DUCT DETECTOR V AC-6 g ZONE 19:DUCT DETECTOR O W 9 AC-7 ZONE 20:DUCT DETECTOR W (n AC-8 Il�r ZONE 21: DUCT DETECTOR V AC-9 Lu rat ZONE 23: DUCT DETECTOR AC-12 O ZONE 24: DUCT DETECTOR U AC-13 O ZONE 25: DUCT DETECTOR ZONE 27; DUCT DETECTOR Q AC-14 PREACTION ZONE 26: ACT DETECTOR NEW PREACTION PANEL Q -15 120V [ C aFIRE SMOKE DAMPER Lo 00 7MI LIEBERT UNIT ZONE 28: DUCT DETECTOR UPS. SEE WATER FLOW FOR DC & UPS ROOMS ' - DATA CENTER ROOM 1/E102. 120V D 74H CONTACTOR FOR UPS ROOM. SEE 1/E102 •• 1 '-_-UPS ROOM---- 1 4 FIRE ALARM WIRING DIAGRAM `� yyyy OVERRIDE SWITCHES E402 NO SCALE ��j\ONAL F� PROVIDE LABEL THAT READS "PUSH TO PREVENT POWER Q� SHUT DOWN". S11085 9� 4jf OF\Op�4 4,y R BRON CTA JOB NO. DELLCC DRAWN ICHECKSO Kee I eLu DATE 10/31/01 SHEET TITLE SPECIAL SYSTEMS PLAN (MEZZANINE) d DETAILS a SHEET N I 4 2 - NORTH r,l (.2 (a� (mil PO 1 1 1 2 1 '� 1 4 GENERAL NOTES So v) I I I I I I I I 1 1. REFER TO SPECIFICATIONS FOR ADDITIONAL DEMOLITION NLLI REQUIREMENTS. _ ¢F-Z �f i �UV i40 2.ALL HEAVY WEIGHT DASHED ITEMS SHOWN ARE TO BE REMOVED. eG Z I I E 1 ! , 74'4 r, a 3.WHEN J-BOXES,WHICH FEED EQUIPMENT/DEVICES THAT ARE TO O ¢W H z I I U I 1 i i I, I REMAIN,ARE.INQICATED FOR REMOVAL,RELOCATE AS,REQUIRED I, it UH 5N Innnnnnnn m BEHIND/ABOVE NEW CEILINGS'AND.EXTEND WIRING. *uH4.PATCH ALL OPENINGS LEFT BY REMOVED DEVICES. COORDINATE rREVISIONS WITH GENERAL CONTRACTOR AND LEAVE READY FORFINAL FINISHES.`IrIr.1, j i GFZ �� I i j j I I l Inn=nnnn7nnnnn=== ===nnnn7nnnnnnnn °""'"_"-" ; ; 5.REFER TO OTHER DRAWINGS (MECHANICAL & PLUMBING) FOR I i i I ; I I ) ` EQUIPMENT,HAVING ELECTRICAL CONNECTIONS,WHICH ARE 1 I I 1 I \cF I'~" I I \CF ; BEING REMOVED. DISCONNECT ELECTRICAL SERVICES. I i 1 4�, '- i I I I I � l ■ I 1 I c BALER CF4, Inn nnnnn7nnnnnnnn CF4, ITnnln nnnannnnnntn Ilnnnnnnnn ---' --------------GRINDER--- ---'---------- ---•— Ili. —'— ------- B - MEAT SAW -C- -ACI. � D •--�.� FLAKER! ' t -------------- T I ----- ------------ I V' , • I,' j 'll I' ` -__L_- y I==---rrxr_=rkc�rr_____7______;_ ,I ii I' ''i �� ,.' V i h, Innnn{nn7_nnnn.n]nnnnnnnn II 1 ' '=r--- -- I+ n ' 1 I +ccc� i 4 E A I SHEET WORK NOTES O hl to iI ! i ! © i� =' �' �,, `�" L i1. ', it � n di I 8 -- " �I'I l' \ + I 1. EXISTING LIGHT FIXTURES TO BE RELOCATED- SEE E201. I 5i .- ----- " I -- - I'I Tt� 1 , .` p+ I Il v JCL It Il, I, ,j` fl I _ __ J__ \` I ''�—�----- �- �� . I " 4l i I I ;� IC7CCCLLx7CLC��!{.LC_rrra 2. EXISTING CONDUIT STUB THROUGH FLOOR. REMOVE ALL CONDUCTORS. u I _- u I I - nA-I < _ — — — — _ _ _ _ — _ — — CUT CONDUIT FLUSH WITH CONCRETE FLOOR GROUTSOLID. \ •_pC4-_tr_�- ! -�- - - =-.'� - - - ip- =i= -.L!- ='7=�Z7- c -ji-l�y.'�5 + ' .:��oMC6=i3� ��':{z:r�_- - -+'- -i - - - - -y\-. .T O I-------7-----�` I '---- •----- ' `, p Y AA ' , I ' 3 EXISTING UNDERFLOOR DUCT INSERTS AND SURFACE MOUNTED I 4 _ ___fit _=z=ea L_=_ STE R n J-BOXES. REMOVE JUNCTION BOX AND ALL ASSOCIATED CONDUCTORS. I ti d I I - I------ - 1.T---{ d �Ia__-4y-----____ -- -- I l ""1 ♦ .+ 1 CUT INSERT FLUSH WITH CONCRETE FLOOR AND GROUT SOLID. 1 °I F=====_=___--- ---- \-to --- -- - --- - - -l-i'«lam««�-��_�==1_ 1 �__ ♦♦ .�'t♦. \ .. tll rt V l` 11 1 - �- �- �,yl ; a � ,. --'1�;♦C `r ♦♦ `�� .-_. `---------------- , e I ) 1i3O, 4. REMOVE EXISTING FLOOR DEVICES AND ALL ASSOCIATED --- *--- -- ---------- ---- �' --------------I-------------------------^1-----------------�- -- 4♦ ♦♦� S` „ CONDUCTORS. GROUT SOLID. / Innnn'Z nn3 MIXER' �'' `C`%% `�•4�'♦ ``�� U j REFRIGERATED I 1 I `--; ,':j`♦ �.�.+ ft 5. CABLE HUNG LIGHT FIXTURES. CASE I I I I , it t', i I I I `j♦`. 11 6. DISCONNECT AND REMOVE ALL CONDUIT & CONDUCTORS ASSOCIATED ==T=====+ `;:•. " WITH REFRIGERATION ROOM/EQUIPMENT. CONDUITS THROUGH FLOOR I --- -'""i --- ----I ! l ! `l�`� ii TO BE CUT FLUSH WITH FLOOR AND GROUTED SOLID. I i I I I ♦�i♦ N� ' �j`:A 7. ALL CONDUIT STUBBED THROUGH FLOOR IN THIS AREA TO BE CUT I FLUSH WITH FLOOR AND GROUTED SOLID. / 8. RELOCATE AS DIRECTED BY M.C. SEE M301. W �m 9. REMOTE ANNUNCIATOR PANEL TO BE RELOCATED. SEE SHEET E401 y N IR RR Sr E FOR NEW LOCATION. 7 m C- ' - - + --------------------- --------------�1--------•---•---------•-•-----•-----W..., - - - - -----•---@ �-r X --- - - - - - - - -'-'- - - - - - -"- - - 10.COMBINATION FIRE ALARM HORN/STROBE TO BE RELOCATED. SEE w LL ---a--a----a--- "-a-!--a---` j I I I SHEET E401 FOR LOCATION. nn�'nnnnnv j i i t I I e I 11. FIRE ALARM PULLSTATION TO BE RELOCATED. SEE SHEET E401 FOR o NEW LOCATION. I I e 12.EXISTING UNIT HEATER TO BE RELOCATED. SEE M301& E301. /1/ ►O�•� J` l i \ I j\ C/'� VJ VJ 1 1 (ll •---a�--a�•--a--- a7 a- I I ' ; I I I ' -- --- cnnnnsnnennnnn_ncnnnnnnnt e I 1 I I U rT I I I I i i i e W ~ 1 1 I e 1 _ _ • —O H� '_ l ----- -- -- of------r-- cnnnr_Y_n---- _:ncnnnnn L_ _--fr _—'------•-- ---------------------------- -a-- ------------------ ------------------ -- r— —I—'----T'—' -�•L�'---."---•-----_n _ --�—_ I � i i 2 1 e e e • g j I i i i I I I :J` Lu ------$---$---- -4- l a ---- \ ` C } �..� �J ; \J` i I ` \` 1 •I' •!. I •;; 1 W ' W _ I � w e -.4_....._. .II. -- t - - - - - - - _'------------------------------------- r—-— — —+—-—-—--r--- --;'I�••— •-------I— --T--------•--- ; ` BCL w � ('�� CC V 7 11 l 3 1 I �I 1 �� r r I r tl i •� I ;1111 tJ ,1 1NAL I-----A-----_- - POWER DOORS j •+ ' I I , I �V�•`iii U _ O �5g\OERf�C/yC` i 1 8 "�, •II I !2� ; \ „' ___��- --------•---'—•�/ 4� 8 --o ---------------- — — — — — •m ----------------- —O 5 -L--•----- ------- - - - -- - - - - - - �•-•-----•-------------IF- - - - - - t G7 '1!--. r POWER DOORS i '+� ,t .Pj,��/•l��'yP n e- \ I I 911 6 I "i' Q8•---�;'�'� � 9�gNE0F �G I; ©REMOTE TEST♦ t! o_ I -- ----- 1 -_ '' -- --'--t--�Ilg,:1' ----- -----0 I J RESET AND LED. _ -- --+----------• L------ jd t \f fi�wrr+var:aasra Isaaaasa — — — — — — — — — — — — O CTA JOB NO. r o —i — — — - - — — — — -0 -- -•- - — F=- Innnnnnn]nnnnr_n7-_nnn I' dam__ T-I - -•--------- r=-� - i°=-'- i="sl. --- - --- - --- K 'J I Ij•------------------- --TI--(�=C��—r=-_-.... . —_—_T----•— --_—_ -1_—_—_-------•—_--- 7 �1 1 I •I I-___ 1_-__ 1_^__ 1__-! ' � 1 1 1 I 1 m DELLGC e I ri g _---�- -I, I, t ii +_-_-•\ r`r;+ \•CIy\ • Y4'i� _�!' ��r *\ '' - '- - '- - O CD i ^ ----- ---•-------•—'----- DRAWN CHECKED ---' O DATE _ _ I 36 \ PowER!DooRs 1 A,� SHEET TITLE 1 i ELECTRICAL i j ----------------•-------•------------------------------� DEI10LITION 1 ------ — — -------------------•------- — — — — — — — — — — — — — — — — — — — — - - — -------------•—i-----------•— — — — — — — �I --- — i PLAN SHEET m j j ELECTRICAL DEMOLITION PLAN01 y WORTH .. • � E501 SCALES I/g" 1'-0" Hi�RTH S Ln S ell o �w oN C=.7 QL-uZ �2V u•• • a O ce _zw V mm= PRIORITY ITEM REVISIONS NOTE: .._.._.._.._.._.. _ C, CONSTRUCTION MANAGER AND UTILTIIES I - --- i �oG R E C E I V E D CONTRACTOR SHALL COORDINATE WITH QWEST COMMUNICATIONS REGARDING SPECIFICATIONS OF S NOV 8§ 20!)1 TRENCH FROM SITE TO BUILDING. Q4iOITY()I I ILLS I I �Gs T. O I - r-- i vo r- i I - :r- I p I \ i \ Emu \ B ADJACENT SHOPS ELL COMPUTER CORPORATION `\� BUILDING TECHNICAL SUPPORT CENTER 1 49,126 S.F, y1 � I I I � I 26' I i � no DELL COMPUTER i I � w I CORPORATION TECHNICAL SUPPORT CENTER - - -• - - - FIRE DEPARTMENT LOCKBOX Z NEXT TO ENTRY DOOR I-I-/ r rn O co CL 851 POLELINE ROAD WITHIN PROPERTY LINES,REPAINT PARKING ® ® ® ® I I LOT STRIPING COLOR PMS 0300 (BLUE) OVER EXISTING YELLOW STRIPING. COORDINATE WITH CONSTRUCTION MANAGER. j TWIN FALLS, IDAHO U �J. 22'-4" 16'4" 43'-10' 16'-6"\43-a... 16'-1" 4 -11"/I6' l"\43 9' I5' 10 43' I0 I7-4" 20- " i i LL J z � OUQ v � z ..... iWj CJ) � w U Lu CTA ARCHITECTS ENGINEERS SITE PLAN GIOI W 1185 GROVE STREET. RECEIVED U ,� U BOISE, IDAHO 83702 NOV o s 2001 CC an of nw',n PT. ^ Q BOISE•GREAT FADS BUI, DE?7. w BILLINGS•MISSOUTA HELENA • KALISPELL W VICINITY PLAN CONTACTS DRAWING INDEX LQ CC U ns+� .g, � .4f; �< ARCHITECT/ ENGINEER CONSTRUCTION MAN,4GER GENERAL NECHANIC:41- ROBE RT BEER Glml COVER PAGE no] HVAC LEGEND,SCHEDULE,SPECIFICATIONS •3 ��� ��' 4�x •�`' \,\ +. STAR CORPORATION M201 HVAC DEMOLITION PLAN LTA ARCHITECTS ENGINEERS 1,: `y •. 1185 GROVE STREET P.O.BOX 46 M301 HVAC REMODEL PLAN i •t '"` PHONF:206 33b49OO TWM FALLS,IDAHO a3103 FAX,208-343-3531 FAX,20 -134-S}1224 FAX,208-T349537 ARCHITECTURAL � O j 1 -.Y L} �ti Ir"pt ram^' 11 ARCHITECTURE A001 DEMOLITION PLAN N cicniecrs BRIAN HAUFF A002 GLAD PLAN ELECTRICAL -I803 )PI?OJECT CTA ARCHITECTS ENGINEERS r JS1TE { �, Al E101 ELECTRICAL BPECPICATIONB, o *uq+[n $ ,h y R PLAN BRIANHfCTAGROUP,COM A102 MEZZANINE ENLARGED FIRE/CODE PLANE r ^"L' LEGEND AND SCHEDULES n �f� l } STRUCTURAL ENGINEERING A03 ROOF PLAN EI03 PANEL SC POWER RISER DIAGRAM AND DETAILS t1 I, L \ A201 EXTERIOR ELEVATKRJS/WALL BECTION EI01 PANEL SCHEDULES �f V - 1 POlelih �' SHAWN REEDER PE CTA ARCHITECTS ENGINEERS A301 DETAILS E201 LIGHTING PLAN y E702 LIGHTING PLAN(MEZZANINE) A302 STRUCTURAL NOTES AND DETAILS E302 POWER PLAN f ryEZZANME) CT B N E301 POWER PLAN / ---,� ❑ -.9. "I, �'# MECHANICAL ENGINEERING A501 ROOM FINISH PLAN i 11 •L i yy r :. �_ A601 DOOR t WINDOW SCHEDULE l DETAILS E401 SPECIAL SYSTEMS PLAN DE TOM DIETRICH E402 SPECIAL SYSTEMS PLAN (MEZZANINE) CTA ARCHITECTS ENGINEERS A901 REFLECTED CEILING PLAN E501 ELECTRICAL DEMOLITION PLAN r' C Filet Ave S DRAWN CHE m , 8 J w _ J ca f a �I :w PLUMBING PLUI"IBING '_j a5 TOM DEiTRICH ATE BH rJ :.8G t1 e13 / J�--T,.? �'�+ II•� _ .' .. \' CTA ARCHITECTS ENGINEERS p101 PLUMBttJG LEGEND SCHEDULE AND SPECIFICATIONS t JS Z` i P201 DWV DEMOLITION AND REMODEL PLANS f Spal4tiAveW ELECTRICAL ENGINEERING SHEET E 3U 4 60 SCOTT WIL SON P301 WATER AND GAS DEMOLITION AND REMODEL PLANS CTA ARCHITECTS ENGINEERS COVE char o Orcna- Dr Amber F IRE PROTECT ION PACE w t J t , C \-_.^ ti -' FP-0 FIRE PROTECTION PLAN !1 ; } _ ftib- SHE E�spU N Rt!`. NORTH 0 REF, ' I C 'T QL L R Q co _ NOTE. H ,{/- NOTE. U ro STAIRS TO 6E 42'WDE, / STAIRS i0 BE 12'UIDE, (36"K TREAD CLEARANCE). u rQ C '�/ (36'MIN TREAD MEAR44CEI ALL HANDRAILS 12"(MIN.) TO TIE WALL AS ,�� r wK 12"(MIN.) PER CODES •� H/r� e N O C ve o L 4X4X3/S CLIP ANGLE Il 4X4'(01S ANGL CLIP E '^ 4' �TNROUiN E�ACN LEGS W/THRO 000LT OR LAG EAC14 LEG OPTION ILIELD UWw POSSIBLE OPTION IIELD M POSSIBLE I� U-1 rl v INSTALL PER CODE 61'I R APED BLOOGNG BEARING: SUPPORT HANDRAIL SEURE CLY - NOTCH ST FER BEA1 PED BLOCKING BEARING W L NO °a (SEE DETAIL WU3) SHOE AS REQUI ED AS PER AND INSTALLm SHOE AS REOUIT�D o �a CONTINUE HAbPAIL AROWD o D5 fd UNI ALL HAIDRAIL6 ENDS CODE 611ARDR41L AS o°� IERTO iI LLI ELL AS C Z)PER . o _ 12 C D5 a o 0 PER STRIVIRAL PLANS -Ve X S GLB 0 0 SNPWN NI0.2 STORM M0-2 23"(MIN,) WELDEDT R4ALIIYaL6MlD o o ECIAL 8 8 BOLTED i0 STRINGERS DS :MRUhII'T 1EAD 4EARANOE D5 0 o V2'07HROUGH BOL75 TO BE 6'•8'rAl i1P. NONE:MO BE NEAR CLEARANCE L X 4'LONG(MIN) i0 BE 6'-8'MIN TYP. LAG$CREW�5'O.C. o M0.1 m o CUMm.1 a a AL STAIRS 3)G)W CLIP ANGLE — AL STAIRS,PRE-ENGINEE7ED BY O1HER5 2MXV8 3VROUGNLEG . 2MXV8-NIP. a L DO= L DUNS-M. M. E10XX _ TYP. ETmXX \� D5 POUR STOP,STITCH IIELD•AS MOD 7 TYP. D5 POUR STOP,STITCH LLELD-AS MOD 3-1/81\13 GLB SMF'f>aTT 1-1I0-2 41 2x SOLID BLOCKING s 48'OL. 3 YOX9 GLB 1 2x SOLID BLOCKING•48'OG �FN TAPS\ 9 GUARDRAIL STAIR DETAIL (srRINGER TO BEAM coNNEcrION) �1HANDRAIL(cp WALL&STAIR DETAIL (STRINGER TO BEAM CONNECTION) NOT TO SCALE NOT TO SCALE IULSU/33r9{w')w'/8 CLIP ALA-E ATHWG THRaC�Cs NAILING INTO ELOCKM 4'CCNC. ON W'4 NONSKID FINISH ° SOFFR 4 FASCIA PER ARCHITECTURAL C12x20.1 Or_ o o - a 71ROUGIT POI1R STOP o TRISSIED BLCCKM OR SOLID 0 A34 TO PLATE z O L UU3/8 3/{•7Ks FLTLLIOOD ° ° CRx201 SPIPSON 93 EACH MMER OR EQUAL EXTERIOR GRADE Q o nI� nII nI� � Q 33C��AP DOL EEqq�� MUL STAIRS iR15S TR-6 uu 4 J W EA$IONT o WSON A-34 EA SIDE,STALGERED Z SHIELD INTO L 2x2xVS-TYP. SREATHMG CONCRETE 3XU8 PLANE,RIPPED i0 MATCH n n n F Ud EDGE NAILRJG INTO PLATE BACI�R FOR SIDING . E10XX TUX4 FRW�CANTILEVERED anaarENT a DIA T1U5N MOM BOLT 5/8'GIP.BOARD •K'on 3lSx9Ci8 U5i—q--'�RIM BACKER STRINGER ANCHORAGE 0)BOTTOM LEVEL STAIR DETAIL(FINISHED) 3 AWNING EAVE__DETAI�TAKE OUT NOT TO SCALE F � NOT TO SCALE �NOT TO SCALE NOT TO SCALE 4'C@NC.SLAB CN IV/-4 I-W DIAK STEEL HANDRAIL Wd NAILS W OC. BAR6 12'O.C.Ed TflRaw POUR STOP 1'CLEAR SKID PIKISN STITCH VELD L 3)GX3/8 CLIP ANGLE �I11M1�•. SA6 I-V!'X3•l2'S1EEL iLT3E Drown by Rf'f W13 UC0l MTORLAEAW G E10XX File NONSKID FINISH Date 54-01-03 PEfFORA1ED METAL STARS 3/4'i4G PLYWOOD _.. EXII:WOR GRADE L2 AIS TIP UIELD�°5'OL.MAX Revisions C12X20.1 + _. ... I L 2X2XU8 _. �� E10Xx 11P. 5/16' . BLOCKING E1018 TYR X 10 JOISTS•16,or_6IMP50N FI6m2/S'GYPSUI BOARD 2100.1 . "OTHROUGH BOLTS 3-VSXS GILD 2M0.1 VS' S TYP. ETmXX H E D Ir �JJ T FRAMING 4 STAIR 6 NOT USED �2') STAIR DETAIL(FINISHED) STAIR DETAIL STAIR RAILING DETAILS NOT TO SCALE F NOT TO SCALE NOT TO SCALE NOT TO SCALE OVERBUILD M"ER5 PER 14"w/n4>ad SIMP.C516 STRAP MSG MANF. BEAM PER PLAN %1PSON A34 FRAMMG ANCHOR C T N 2x NALERS 6FA NOTES ROOF SHEATIN6 O (n S 7 ro v ti 10 J ca GIMP C6W 10 17 2x STUD WALL 3 a NI i� MM's FLAN TOSSES ~W JOIST$OR � � � wv FRA N [ x NOTE:SHEATH ROOF PRIOR TO77 N ti OVER SUILDM6,TYPICAL HIACE MOUNT 8" BEAM PER F'LAS 0) W STUD WALL LJ g o Lw ro NOT USED DETAIL _ DETAIL DETAIL o �� 13 NOT TO SCALE 9 NOT TO SCALE NOT TO SCALE NOT TO SCALE o C O ROOF SHEATHING C 0 O^ 05L TOP PLATE I"NAILS AT 11 6'Or-TY R UNO, 2x4STLID WALL EN. EN. 14" 14" 6 STRAP WTH 141 ed EA.END (2)2x TOP PLATE 7 DOUBLE TJI OR FLOOR J01575,SEE FRAMING PLAN 1-114'RIM JOIST E Z. M a 8541 � SPLICE FERiOP PLATE 6eOZAL NOTES 9 9'FbF TRU55 TAP - N raa°�P 2x45111D WALL 2x4 SILL PLATE PLAN VIEW W/16d•24'Or- MO TPoJSS 14 NOT USED 1 DETAIL 6 DETAIL 4)DETAIL NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT To SCALE 2x BLK'G W/ "A35"EA.BLK 2.NAILER W/ GYPCRETE TOPPING EN. 16d-12"O.C. PER ARCHIGTURAL 16d NAILS AT 6"O.O.TYR UNO, EN. Tien TJI BLOCK _ P 11d'FT EN. EN. s d8"O.C. FOR DRAINAGE EN. FLOOR JOISTS, SEE FRAMING KM N SIMPSON HJ CLIP EA TRUSS TTP. w O EN. 06L.TOP PLATE l I 4 DOUBLE TJI OR 1-1/4"RIM JOIST FASCIA PER ARC , n n I�KJ Z TJI BLOCKING I I I W r RIPPED J0151 Ibd a roll on EN. �J > PER PLAN 13'4"xll X"LSL RIM BOARD FLOOR JOISTS, 2x4 BLKYs W1 SEE FRAMING PLAN 16d s 6'— SMPSAON'IUS'HAMER BEMt W4Ef�t2OCJA25 'LU52V, UNOTNOT USED DETAIL � DETAIL DETAIL TO SCALE NOT TO SCALE NOT TO SCALE `� NOT TO SCALE (BArod BRAC TO 8T L EN. ERI EN. W%2x&f LLATE9d STUDS VW x4 111epk EN. 16d•6"o.c. Wal NAILS AT SHEAR WALL,SEE SOWED Drawn b RM Y • ,c. • o E'N' Is/�'x9 l/2"LSL W/SIMP roll O.C.TYP.U.N.O. Aid•32"Or-STAC-CsERED FLOOR SWEATING File 10d NAILS AT DO NOT SPLICE AT WALLS Date 8-01-03 FLOOR JOISTS, Revisions TR U ill MA SEE FRAMING PLAN 2x4 8 z. C3716d T J9 WEB STIFRNER TJI BLOCKING FLOOR JOIST F'ER PLAN Ibd NAILS AT LAP SHEATHING OVER TOP PLATES 71 EN. 16d EA.JOIST - 6"O.C.LS U.N.O. OCCURS 2x4 CJ.•24"o EN. 2xS BLK'G W/1 a " C. EDGE NAILING S EW/2xS PLATES 6 STUDS T I FLOOR FRAMII,* NOT USED (�1DETAIL DETAIL (�)DETAIL DETAILS 16 NOT TO SGALE NOT TO SCALE NOT TO SCALE NOT TO SCALE 2zY!PLATE with(3)16d ROOF TRUSS-SEE ROLE FRNMPG M-6A 2x4 STUDS•16'oc STUDS GNU EA TRUSS NU PLATE NOT SHOWN FOR CLARTY IBd 0 6bc PLATE TO BLOCIOWG EN.—16d W.OZ. AB SOLID IGLOO"with VENT HOLES. BLOCKING BEIUEEN JOISTS WT14 Ibd 8'oc • - E1N. SET TOP TIGHTSE TO a SIMPSON A35 32'oc .c Is34 I/2" O W/SIMPAGG 2xB FRAMING a 24'oc- PLYWOOD 91EA1HIN's Aid•O O.C.STAGGERED r B'THG 8'-®'MAX SPAN 3/4'11G RR DECKM3 L r 7JI BLKG 048"O.C. (/ SOLID BLOCY.m > BETWEEN RAFTERS Q wv (2)I0d AT EA JOIST CRIPPLE WALL AT iR155 PANEL J co POINTS•V-0'oc MAX SPACING FLOOR JOIST SEE PLAN m SHAFED PLATE with(2) DEL.TOP PLATES.STAGGER ALL 16d EA,BLOCK U r; FLOOR JOIST PER PLAN I6d a EA TRUSS LAPS 4'-0'4 NAIL PER DETAIL Q) EN. 1002 a LAPS,8'ac TYP. C ¢ DBL TOP FLATS STAGGER STIb WALL ALL LAPS 4'-0'4 NAIL PER N DETAIL 002 AT LAPS,Woc,TYP. ,C vqi VOf ERA 2xb STUDS KCAL ROOF SMY5,CONT SRIPSON HI OR H25 EVERY 5flFAR WALL WN&-EMEND COAT.TO TOP OF 11124 PLATES 0m OVER-BUILD TO BEARtYe (LOWER FLOOR ONLY) WALLS a BENTS. OTHER TRUSS STAGC#R£D WALL(SEE SHEAR WALL MOTES) C L j a o z 3 DETAIL �TYPICAL OVER-BUILD 1SOLID BLOCKING ISOMETRIC l FLOOR TO FLOOR SHEAR TRANSFER NOT TO SCALE NOT TO SCALE � ' NOT TO SCALE o C O C p o 7x'OVER BUILD r 10d-41oc WALL WHERE OOCURs JII, EX SIMP50N We AT EA.2x' 2x4 PLATE with 16d a" � PROOF SHEATHfYs SIM",i0F1 HI1210 I0d�b'oc FLR DECKING i0 BLK'G FLOOR SWEATING AT EA JOIST �-TYP.ROM DEC" !��R CNN) BLOCKINNG Ai 3Y'oc x x t rx/�-v UES STIFFENER a 32'oc FLOOR JOISTS, WALL SHEATHING SEE FRAMING F'LMl POOH GIRDER ROOF TR1S4 I? TRUSS a E:-J MULTIPLE TRUSSES PER I'm II-T)8"M.L,COAT.WITH SIMPSO N A35 to 7yy Di BEAM F£R PLAN I'm A35.14'oc 2)(I0 JOIST •EA.BLOCICIW.4$IMF"A35 AT 51MPSON'IUS"HANGER g n{,A 2g Z WALL SCH EDGE NAILING PER SHEAR (OR PER PLAN) 32'oc TO WALL TOP ELATE. v 8 4 tT1� EDULE EDGE NA ILNG AT EA TRW OF ` FER FLAN 2x CONS.LEDGER BEAN 2z4 SUDS 16'oc with(2)ROM 16d•0— ROLE TRUSS PER PLAN 8HTH'G CONT.TO BOT H TAPS OF ROM SHEATHNG AS SNOON SHEAR WALL SHEATYx -EMEND CONT.TO TOP OF WALL.(SEE SHEAR WALL NOTES) DETAIL (J�ATYPICAL FRAMING at GIRDER TRUSST INTERIOR SHEAR WALL TO ROOF DETAIL ' NOT TO SCALE NOT 7o SCALE NOT TO SCALE NOT TO SCALE GYF'CIRETE TOPPING PER ARCHIMRAL TYPCAL ROOF DEWWS-RN CONT.UNDER 2x NAILER W/ VALLEY FRAMING 4 VALLEY BOARD To 16d®12"O.C. WALLS a BEAMS TYPICAL FINISH SYSTEM -FER FLAN RAPIERS AT 24'oc RIP V4'Ft Bi FELT FOR DRAMAGE FLOOR JOISTS, Q SEE FRNMINS PLAN WALL SHEATHING SIMPSON A35 a i Balk NM 8d NAILS) w p At EA RAFTER _- ------ - STEP FLASHING n�FT WALL DRIP DIVERTER ROOF DECKING I I 1 I I) Q L-J � ALUM DRIP EDGFTTP I h A x30 ROOFING FELT Z RIPPED JOIST POOH v ~ ROOFING SHINGLES ROOF A131-AN 13'♦"x11 Ye"LSL RIM BOARD ALUM.GUTTER 2x4 BLK'G WI 16d•6'oc Sry�,"p(.U'US'PAMER EXT.WALL EMB1DW, 'LUS28" BEY01D�� 242 VALLEY RATE NAIL 2x4 BLOCKING(LAY RAT) TO EACH TRW with(3)Ibd NAILS •24'oc with SIMPSON T CLIP a ECI UAL 34mlth 8d NAILSTg. DETAIL DRIP DIVERTER ISOMETRIC ��� LLEY BOARD NOT USED ' NOT TO SCALE NOT TO SCALE �NOT TO SCALE 3 Not TO SCALE ©ATTACH 8'SILL STRIP with TOP EDGE LEVEL with ROUGH SILL,EMEND 8'BEYOND. SECURE ALL FLASHING MATERIAL with OALVANI22A NAILS 4 QATTACH 4'JAMB STRIPS with SIDE EVEN TO PARALLEL 4' ROUGH JAMB.START I"BELOW SILL ROOF SHEATHING —. STRIP 4 EMEND 4"BEYOND HEADER Tyr. 3.INSTALL WINDOW INTO ROUGH OPENING with 2x�' ' SHEAR WALL SH1H'G CUNT. Drawn by RM Q 48'oe I'dla.Yc?Nf HOLES i0 F40OF File FLANGE5 ov FLASHING. (2)PER BLWC IN TO HALF OF BLOCK Date 8-01-03 40.ATTACH 8'HEAD STRP over WIDOW FLANGE SOLID 13-00Wx LOW ROOF DECKING I0d a 4'oc DECKING TO N6 Revisions SIMPSCN DTC CLIP PAR $ TYP. Q STARLING AT SOLE PLATE,LAY BLDG.PAPER 48'oc UNDER SILL STRIP.-NOTE-CONTINUE BLDG 51MP5GR1 A35 a 24"oz 3O PAPER am WINDOW SILL 4 JAMB FLANGES. O O WlGFI DO NOT SPLICE INTO RAS141%STRIPS. OPENING U Q 2 1 NDOULAR DEL TOP TRI.%a RAFTER 2x6+32'oc wlth CONT.9HIHG 10 FLOOR BELOW PLATE PER PLAN SIMPS N A35 Ai EA END S SHPSON DTC CLIP•48'oc PARFIIICN 2d2,CONT.with(3)Ibd AT EA E v D O WALL c TO BLKYx CONTRACTORS OPTION: STUD 4 l6d a Wo M LIEU OF I la.VENT HOLES,USE SOLID,FILL Hi. T BLOYMING BETWEEN TRUSSES.REMOVE EVERY 4tth BLOCK ROOF FRAMING 6 WINDOW FLASHING DETAIL ��ICAL PARTITION TO TRUSS t-WENT HOLES IN TRUSS BLOCKING ��LOW ROOF SHEAR TRANSFER DETAILS NOT TO SCALE ' NOT TO SCALE NOT TO SCALE 'T NOT TO SCALE N. L EN. 200 PLP FRS- IINEERED TRUSS (3)16d BRACE TO JSAT VERT.2 2.4 BLK'G EN. x m d8"o m 48"oc. PREFABRICATED TRUSS 01 SNAPS TOP 10 MATCH PREFABRCATED TR1S8 C BEAK-PER PLAN ROLE SLOPE.ALL BLOCKIW .� MEMBERS OF TRISSED SHAPE TOOP{TOgLMLAT04 ^ 1 BLOCKNG ARc 2X4'S MN MEMBERS Of-1R1 my Q L ;r •A34. BLOCKING ARE 2X4'S 3 cn ONE EA SIDE AND AT �p�pNpg3p;7 Q (n �TRUS I MAX. BOTTOM OF TRUSS ELK �ttOM61 TRUSS BLK (� J 2x4 BRACE®48'P TRL�PER MArtF. tit C3J16d BRACE TO ST W DBL.TOP PLATE C Y 'SrP WN'OR EC UAL o TOP FLANGE WARING CONNECTION a EN6 DBL.TOP PLATE R'D BEAM W44GER EN. X 2x4 C.J.•24"o.o. W 2x8 BLK'G W/16d SECTION w �o 0�11LITIIH BEAM TO BEAM CONNECTION �avQETAIL DETAILNOT O SCALE NOT TO SCALE T NOT TO SCALE 'o C 'z C O C � O o SIMFSON ST 6224 a COT. SMPSON ST 6224 TOP PLATES PER HEADER SITE ulth(5)16d MIN EA SIDE IEB S71FfENER HEADER or BEAM REA.SIDE . EQUAL UAL PER PLAN BEAM-PER PLAN 16d•6'or_ �� WALL WERE OCCURS SIM 50N NMlGER ii u PER PLAN EN FLOOR SFEATNG ER FLOOR JOISTS, SIMPSON EPC a ACE 2x4 STUDS CONT. SEE FRAMNG PLAN POST��-TTP.at EXT.WALL TO TOP EA SIDE q�ocim > POST a MJLTIPLE STUDS �PLYM SPACERS STUDS BEAM PER PLAN - E541 ,p PER PL/W // 24S Se I6' PER EDGE NAILING / TJI BLOCKING 999�OF\�P •48,on TAP��P x STUDS t oc NOTE:SEE PLAN FOR SITE OF or PER PLAN FRN11NCi MfJNBER6 4 HEADER BEARING_ IN WALL ��1JOIST HANGER CONNECTION BEAM POCKET IN WALL DETAIL NOT TO SCALE T v NOT TO SCALE NOT TO SCALE NOT TO SCALE USE EVERY OTWR NAIL HOLE M A ROAM TO PROVIDE THE CODE 'J(3� ' with R'-CAIRED MN CENTER n LER SPACING FOR NAILS. J—r 14" 14" WOOD[-JOIST(Be PLAN), I6 STRAP WITH with(2110d AT EA BEARING PONT (d)Bd EA END 4 a> LEN'a1H z � SOLID I-JOIST BLKG. SEMEN JOISTS with(2)10d 0 AT EA.END FLU n 4 — I Q 16 -4 CLEAR SPAN DBL.TOP PLATE,STAGGER (2/2x TOp PLATE 4 u ALL LAPS 4'-0"T NAIL PER DETAIL YR. AT LAPS, ROWS OF I6d•16•oc EA SIDE EtD LENYs1N I6"oc TYP. CONT. FOR MEMBERS 8"DEEP a GFEATER FOR MEMBERS LESS THAN 8"DEEP SCUAL UMISER OF SPECIFIED 2x4 STUDS•WALLWoo TYP 5PL�GENERAL NOTES a USE(2)ROWS 16d•16'o0. NAILS IN EACH DO, AT BEARING WALL F'RW E MINNWM T/8•DISTANCE TO END OF STUD FOR C5I6,END LENGTH' PLAN VIEW 11'MK NAIL WITH(22)10d, (IU 10d EACH END. - Ui_5,_'�TYPICAL BUILT-UP'2x'HEADER 1-4-AST HOLD DOWN �1TYPICAL SOLID BLOCKING 3 DETAIL NOT TO SCALE NOT TO SCALE t NOT TO SCALE NOT TO SCALE Gd 100C.INTO GABLE END TR1S6 16d•24'OL. ROOF%EATING BLOCKINYs 2EIL0d EA BRACE 2x4 STUDS a 16'oc T1P. W/( (8)T6d NAILS at SPLICE Kd•d'oc - DOUBLE10P PLATE SIIPSCN A35.241= 4'-0" STAGGER JOINTS Drawn by RM MAX a 10d•DECKING file 3/4'TfG fLR DEdCING 2X6 fASGA 16d EA RAPIER Date 8-0I-03 FLAT Revisions NOTCH TR1S6 AS JOISTS or RAFTERS R NOTCH IffQD La PER BAN GABLE END TRUSS4 g�,q(OR FRAMED WALL W/ W/FRAMINGACHID SOU P WOOD I-JOISTS(SEE PLAN) SOLID BLOCKING) END.BRACETO TRUSSESLf ROLE-TTP.I-Vd"RMiJl.BLOOCINIG BEIUEEN lal(2)JOSTS T/I6'SFEAiING,SEE COMMON TRUSS BOAT'vD 48'oc TOP(B01TOM EDGE NAILING at 61 EAR WALL SCFEDULE PERIMETER t TO A4 DBL.TOP PLATES.STAGGER ALL LAPS 4'-0"4 NAIL MR DETAIL 4 BEAMS. 8t WALLS 7::�_611PW N A34•16,OC, t E EAMs. -SEE g 10/D2 s LAPS,8'oc iTP. 8d NAILS D DOUBLE T $iRUC7URAL NOTES CHORD AND pOUBLE TOP 2x4 s W Or- H 2x'8TUD8.16'oc PLATE,SEE SHEAR WALL L E D SHEAR WALL SHT44'G-EXTEND CONT.TO TOP a PER PLAN SCTEDME FOR SPACING OF WALL(SEE SHEAR WALL NOTES) E T FLOOR FRAMING 6 FLOOR TO FLOOR SHEAR TRANSFER 2 TYPICAL TOP PLATE SPLICINGTYPICAL HORIZ.SHEATHING LAYOUT 4 DETAIL pE7aILs NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE 4'CONC.SLAB _.. _. FTG. (2)4 HORZ TOP 1 BOTTOM x 5/8"0 AS•32"Or- DEPTH V4 x D OPENING SIZE.-4'-1"La"i ' (2)4 T x FILL CH SIDE 2'-O" 04 REBAR•TOP (2)5 DIAL, C N WALL B.4 SLAB DOWEL 24'Or- 7 ro \ ' . (2)4 CONi.REBARS•BOTTOM 9 TYPICAL FIORZ. 1.` J^ TYPICAL FT'G y NOTE:TYPICAL WALL RFI F. (2)14.4'-0"DIAGONAL c • REINFORCEMEN ONOT R GLAg R Tim' BARS,T1P,AT COkJERS Li,2 Q.o �V 00l DETAIL TYPICAL FOOTING STEP WALL OPENING REINFORCEMENT T� 00 C)WO—TTO SGALE NOT TO SCALE 5 NOT TO SCALE NOT TO SCALE o .E ro 2"GLR (2)4 BARB •TOP OF WALL d OW SHTH'G AT INTERIOR SHEAR WAILS ONLY.. S (PER FLAN) •• a. 4 x d 4 oanELs•Ia'Or- AT INTERIOR SHEAR WALL 2x4 STUDS AT 1610� —III— ( HORZ(EARTH SIDE OF WALL) USE 5/8'dia.x IV AB. (a PER PLAN) I I I •32'0c EMBED 8-V2'MN I 2x4 P.T.SILL F'L4rE X INTO CONC.FOOTINi SET TO Q . ALLOW POURING OF SLAB BELOW I -0 CONT.FTFry.a MONOLIT(IG U TOP OF AS5E 2'.2'z 3A6' � 19 r WASFERS CONRACr SLAB Per 'x @ 4'LONG SLAB SEE FOOTING CONTRACTOR'S OPTION c^v AND FouNDarIGN PLAN -4 BARS OR w/ m J' i , _ d=BAR DIAMETER OF (EARTH DOWELS 4 x d FOR 15 BARS 4 SMALLER USED AS STIMPS 4 TIES ° ° 4 DOUELS•Q°OL � D=5 x d FOR 03 BARS THROUGH 08 BARS 0 FOOLING PER SCI-ED 9' -ofP��' (2)4 COW. TAao D=6xd FOR 0%0104Oil BARS 24"' INTERIOR FOOTING TYPICAL HOOK&BEND FOUNDATION DETAIL (FOR WALLS RETAINING BTWNr4 allo6'-0') ONOT TO SCALE NOT TO SCALE 6 NOT TO SCALE NOT TO SCALE (2)4 BARS •TOP OF WALL SEE JOINT T/10 ___ '4 DOWELS•12'Of DETAIL HORIZ(EARTH SIDE OF WALL) 2T5 CONT.BARS � _I III I I I o 4'CON-SLAB SEE FOOTINS m JOINT SEALER FOR ` WATER PROOF AND FowoanoN PLAT( i sao a=°s aoaaeao=°s ae=aesoe Jows LET E CORNER BARS MTN s o 2' ✓ 36 BAR•LAP = CONSTRUCTION JOINT SECTION ° n n n a n 0 o u ° Z " .IS"Or-(EARTH OR $ SEE JOINT ,, a CORNER OF WALL TB * SLAB REI F. lF"ER ENGR.) CORER BARS MTN I m nII n T(IT� z e 36 BAR m LAP .BARS w L� r V8"FIBERBOAT�STRIP, ZIP STRIP,OR SAW 4 DOWELS•24"OC JOINT DETAIL - a . CONTROL JOINT SECTION INTERSECTION 24„ CONCRETE SLAB JOINTS FOUNDATION_WALL_REINFORCEMENT (�)RETAINONG WALL DETAIL(FOR WALLS RETAINING 2'-8"OR LESS) O�NOTTO SGALE NOT TO SCALE NOT 7 TO SCALE NOT TO SCALE ALIGN HOLD-DOIIN EMBED,WITH END STUDS,WINDOW POSTS,OR DOOR POSTS. CCppN�IC�IK FLOOR SHTH'G Drawn by R•4 SLOPE PER CIVIL ENCx DLLGS. '3x'POSTS OR(2)'2x'9111D4 WTH � FINISH GRADE FINN15H AB File BEYOI I0d•8'o4 EA.SIDE,FILL HT. (RE:PLANS 1 SHEAR WALL SCHEDULE) Date 8-01-03 m 3 SIMPSON 6W14 RJ WITH 16d NAILS, Revisions 'PER SIMPSC41 RECUIREIMLMS, STARTIW.•TOP(SEE FOOTING! RIM JOIST FOUNDATION PLAN FOR APPDX LOCATION) (21f�BAR4 0r BL ' Qf FOLNDATON '3x'POST OR(2)'2x'SIDS WITH 10d a 8"=EA SIDE,RUNT. s" (RE:MANS!SHEAR WALL SCHEDULE) SRPSON SM14 WITH Y d NAILS, •PER S11FS0N REOWREMENTS 5 (SEE FOOTING 1 FOWATON H t' PLAN FOR APPROX LOCATION) E D INSERT EMBED,FOR FOWATION E BRICK YENEER T FOUNDATION Nor To SCALE TYPICAL L FOOTING AT WOOD COLUMN 4 No PIoC LLHOLD-DOWNS DETAILS 18" LVL RIM JOIST SIMPSON MSTC28 FROM RIM I DATE ISSUE 06/25/08 SCHEMATIC 2X4 DF1 BLOCKING JOISTYPT II 4X BLOCKING ® LEDGER, II II II II II 10d NAILS ® 6" O.C. 18" TJI 560 EACH END OF SHEAR WALL II II II II 07/31/08 PRELIMINARY FLOOR JOISTS 09/04/08 CONSTRUCT. II II II II II 3'a" OSB STRUCTURAL 10"X16°X8" CMU BE 2X6 TOP PLATE OF II '%"X12" II II II II LBV.56/18 METAL GRADE FLOOR DECK TOWER 10/27/08 ADDENDUM#3 LOWER LEVEL FLOOR II p %"X4'X8' OSB STRUCTURAL PARALLAM II II II II SIMPSON TOP FLANGE EXTERIOR WALL II II II II AND EXTERIOR GRADE LEDGER BEAM II II II I II JOIST HANGER W/16d Y2"2X6" PRE-DRILLED II II SHEATHING W/ 10d NAILS ® W 3/4"2X8" LONG II II II II II / NAILS TO HANG EXPANSION ANCHOR BOLTS MEgauMuaAmsPEanurousAsiNsmuuFeis ' 18" TJI 560 II I 6" O.C. EDGES & FIELD COUNTERSUNK I I I CONTINUOUS 2X8 0(�ERA¢FORMPR6ECr IXX1N E WE MADE 0 16" O.C. II II II JOISTS FROM STAGGERED 1'-0" O.C. AND SKU REWAm7HE PRW TY OFH EVEWEEN RM II II II II %"X4'X8' OSB W 12d EXPANSION II II II II DF1 NAILER SNON lLt BEGNNIFR F X MEQ S WWOED. II / ANCHOR BOLTS II II II PARALLAM BOOM SEDBYMYONE OWP 3Y2"X12" NAILS ® 4" O.C. ON I awunasnMsPRM0TWWHv II II II 2-3/4"2X8" LONG PARALLAM II II EDGES & IN FIELD mu rasmfwux,uwEc.caNarpzoo II II I II II EXPANSION ANCHOR LEDGER BEAM II II II II 2X6 INTERIOR II II W/3/a"OX7" II II II ---LT METAL SIMPSON WALL BOLTS ® 2'-0" O.C. COUNTERSUNK TOP FLANGE JOIST HANGER 10"X16"X8" CMU LAG SCREWS ® W/16d NAILS TO HANG TOWER O 2'-0" O.C. JOISTS FROM PARALLAM _ u Q J J D FLOOR LEDGER BEAM @ 2X6 WALL FLOOR LEDGER BEAM @ CMU WALL 2 FLOOR CONNECTION @ CMU WALL 3 (A SCALE: 3/a"=1'-0" A-4 SCALE: 3/a"=1'-0" A-4) SCALE: 1"=1'-O" A-4 Z W H 2X4 DF1 NAILERS W Z W 2- "2X4" A325 BOLTS " 3/a" OSB STRUCTURAL z ~ - 10 3/4"W (I.D.)X -6"H GRADE FLOOR DECK Qz = (LD.)X4"DXY2" A36 P MADE g STEEL SADDLE Q e •- 90'-0" FOW ujN v ce Ye"X4"X4" \\ z LL a TRIPLE 18" TJI 560 FLOOR / ce z z W o 2-STORY STEEL I JOISTS ® 16" O.C. W/ W t TUBE COLUMN w IW- a ON BOTH SIDES W 8X31 1 P® 3-Y2" OSB WEB SIMP. MSTC28 0 o STIFFENERS ® EA. SIDE LEDGER TO RIM OF STEEL BEAM -18 Q e d OF TJI GLUED & NAILED = U n ® EA. END OF 5 . . 5 I W/ 8d NAILS Q z c SHEAR WALL, -1 e - - -- -16 3Y2X12 PARALLAM W/ o b o o a N TYP. ° ` 3YV'OX7" LAG SCREWS I W 16X67 STEEL BEAM at` W LL z d V W J AT 2'-0" O.C. F- $i g <6 W 18" LSL RYP JOIST 4"2X4" �,4" SIMPSON OMIT JO STDF1 X R I E D OP A325 BOLTS �C�I` FLANGE HANGER BLOCKING I T TYP. - HFD ; Q 6., 6" TJI 560 AND BEAM CONNECTION DETAIL 4 J ce a PILASTERS 1 I PILASTERS SCALE: 1Y2"=1'-0" A_4 O Z Z o TYP. TYP. U Q m m e>D 3 1 1 2X4 DF1 NAILERS 3 W N p 0 0 - 2-3/4"2X4 325 BOLTS U Lu _ � A-1 A " -t8 3/4" OSB STRUCTURAL 0 - LL z Q 0 10 3/a"W (I.D.)X 1'-6"H GRADE FLOOR DECK zLt o U (I.D.)X4"DXY2" A36 SHOP MA O w 1 1 STEEL SADDLE rj 0 CL H Q 0 A-zo 1 F -zo h Q zO Z TRIPLE 18" TJI 560 FLOOR N N �— JOISTS ® 16" O.C. W/ z N 3-Y2" OSB WEB Ov o P® o o STIFFENERS ® EA. SIDE z OF TJI GLUED & NAILED Q SIMPSON L U SIMPSON ITS1.81/ I W/ 8d NAILS Lu 11.88 TOP 11.88 TOP FLANGE FLANGE 6 S 6° HANGER W/ WEB ° b W 16X67 STEEL BEAM HANGER W/ 6" STIFFENERS TYP. WEB 2X4 DF1 STIFFENERS JOIST TYP. BLOCKING �,4" I, SIMPSON 0 M IT �jSED ARC R ELEV. TYP. A �a BOLTS �f- LBV3.56/18 TOP 0 0 SIMP. MSTC28 FLANGE HANGER * " AUReaaD1 y �O STAIR LEDGER TO RIM ® �� -z8 Oe "X4'X8' OSB OPENING 3Y2"X12" PARALLAM 3Y2"X12 WALL,NTYO F SHEAR 9 LANDING BEAM- PARALLAM W/ 3/4" TRIPLE JOIST GIRDER SADDLE DETAIL 5 -$ TFOF�pP STRUCTURAL GRADE 2-STORY ENTRY PROVIDE BEAM 2X7" LAG SCALE: 1Y2"=1'-0" A-4 FLOOR DECKING 3Y2"X1 (OPEN TO ABOVE) POCKET IN CMU SCREWS AT PARALLAM M 'C�' DRAWN PROP/PROD BEAM FOR LANDING BEAM 2'-0" O.C. D.LARNA ES08.0006 V2 X12" PARALLAM - —— — —— —— — — BEAM CHECKED DATE L. FLOOR FRAMING NOTES: SAW 10/27/08 1 y4"X4"X4" STEEL A-1 SQUARE COLUMN 1. JOISTS: 11%" TJI 210 FLOOR JOISTS ® 16" SHEET TITLE O.C. THROUGH OUT. UPPER LEGEND: 2. WEB STIFFENERS: 1-5/8" OSB WEB STIFFENERS ® 10X8X16 CMU WALL ON EACH SIDE OF TJI GLUDED & NAILED LEVEL FLOOR Q ® 2X6 SHEAR WALL W/4-8d NAILS MINUMUM EACH SIDE TYP. FRAMING 3. JOIST HANGERS: SIMPSON ITS1/11.88 AT ALL PLAN UPPER LEVEL FRAMING PLAN JOISTS. SCALE: Ye"=t'-0° �� 4. SHEATHING: 3/4"X4'X8' STRUCTURAL GRADE SHEET FLOOR DECKING WITH 10d NAILS @ 6" O.C. AT ALL PANEL EDGES AND 12" O.C. A- 4 OTHERWISE. REF. ADDENDUM NO. 3