HomeMy WebLinkAbout23-0236 138 Meadow View Lane- BRS Twin Falls Permit Set REV-A--void CODE ANALYSIS: Knox Box Installation o� Z_ W o B,E-H A Knox Box shall be installed o _ z N BUILDING TYPES: LIB BUILDINGS B-H VB BUILDINGS A AND OFFICE to the right of the main access z00 SPRINLKER: NOT SPRINKLED door(s).It should be mounted Q FLooas- between 5 and 6 feet from o 0 J o MAX BUILDING HT. 25' ground level.Alternative ffi w 0— locations will have to be CODE ANALYSIS: o 0 approved by the Fire Marshal. G z z = C Q BUILDING A AND OFFICE F OCCUPANCY: B/S-I -NO OCCUPANCY SEPARATION REQUIRED- OK 12 m o U) U) D SQUARE FOOTAGES(GROSS): w • OFFICE: 1350 SF 12 ono } STORAGE: z250 SF Install portable fire extinguishers to meet the �o � U F TOTAL SF- 3,600 SF requirements of NFPA 10. Fire extinguishers EXIT Loan 6 EXIT LOAD 6 12 -5 W U MAX HT= 40'ALLOWABLE OK a o Z shall be 5 LBS with a minimum rating of gz = Y MAX STORIES:2 ALLOWED OK LLI MAX SQUARE FOOTAGE: 9000 SF OK 2-A:10-B:C rating and spaced based on one EXIT DISTANCE - U U J EGRESS: 2-A rating for each 4,000 sq.ft.of floor area, -EXE LOAM =60'=MAX. I OCCUPANTS: OFFICE= O9 COMMON PATH z Q Si = 4.s with a maximum 75 ft.travel distance to an ac, TOTAL= 13.5 USE 14 extinguisher shall be mounted on hangers or EXIT DIST. EXIT DIST. « Tn EXITS REQUIRED:I brackets,or in a cabinet. If a cabinet housing is 50' 50' EXIST SHOWN:1 EACH SPACE OK co MAX EXIT DISTANCE 100' provided,the cabinet shall not be locked, z w MAX EXIT SHOWN: 60' OK mounted handle at 48"A.F.F.Extinguishers J 2 HR.EXTERIOR W MAX COMMON PATH= 100' shall be conspicuously located along normal RATED WALL WALL w w o COMMON PATH=MAX EXIT EACH SPACE=60' OK paths of travel,where they will be readily W EXIT LOAD 6 J EXIT LOAD 6 __J o EXIT LOAD BUILDING C&D accessible and immediately available in the > 5 w OCCUPANCY S-1 event of a fire. The fire extinguishers shall be SQUARE FOOTAGES: 9100 SF(EACH) O EXIT DIST ❑A z z N L nt with inspection/testing and provided o 28'= o Q MAX HT. 55'ALLOWABLE OK � W MAX STORIES:2 OK a qualified and approved inspection.(IFC ¢ COMMON W PATH w MAX SQUARE FOOTAGE: 17,500 OK NFPA 10) g 'ow MAX AREA WITHOUT FIRE BREAK: 12,000 SF OK OCCUPANTS: 19 EXITS REQUIRED I • • • • EXITS SHOWN 3 OK Exit Signs: 12 EXIT DISTANCE ALLOWED: 200' Emergency power shall be provided for EXIT LOAD 6 EXIT LOAD 6 oN MAX EXIT DISTANCE 60' OK exit signs as required in Section 12 1 i LIC SED 1013.6.3.The system shall be capable i RICH TEC of powering the required load for a 3 z AR-98 380 PLUMBING FIXTURES: duration of not less than 90 minutes. WC: °(B)+ (S-1)=037-1 REQUIRED OK" LAV A(B)+4(S-1)=0.64-1 REQUIRED OK-+ o w MOP SINK 1 REQUIRED OK DID: m 2 OF 1 REQUIRED-1 DUAL HT.SHOWN OK 1008.3.3 Rooms and spaces:In the event of power supply a N failure,an emergency electrical system shall automatically _ F ANo illuminate all the following areas: H J •* WHILE WE ARE AWARE THAT THERE ARE OVER 15 OCCUPANTS.FROM OUR EXPERIENCE,THE USAGE OF THESE 1.Electrical equipment rooms. o SPACES IS VERY LIMITED AND THEREFORE WE REQUEST THAT 1 RESTROOM BE ALLOWED. 2.Fire command Centers. 3.Fire pump rooms. 4.Generator rooms. S.Public restroomS with an area greater than 300 squ wo 3z o� BUILDING AREAS AND OCCUPANCY CALCULATIONS: BLDG SQUARE FOOTAGE OCCUPANCY CA-CS REMARKS W W A 2250 SF =4.5 OCCS DOES NOT INCLUDE THE OFFICE AREA a w !r'� Z B 6200 SF 0 NOT OCCUPIED EXTERIOR ACCESS KIMBERLY R D i V (, C 9100 SF ,9=18.2 Z V D 9100 SF =16.2 c-'o Z W_O E 4200 SF 0 NOT OCCUPIED EXTERIOR ACCESS Q Z F 5,600 SF 0 NOT OCCUPIED EXTERIOR ACCESS w G GOOD SF 0 NOT OCCUPIED EXTERIOR ACCESS z a m O O O LJ H 7800 SF 0 NOT OCCUPIED EXTERIOR ACCESS CWD U) OFFICE 1350 SF =9 FLOOR PLAN wo z < V J Z O ��//�� o SCALE: 1/4"=1'-0" w 3 0 W/ V) O TOTALS 51,600 SF S1=40.9-USE 41 U7 r•� J 0 O Z B=9COOS c' W Z Q TOTAL PROJECT OCCUPANT LOAD= 50 COOS NORTH J Q J a Z > Q 0Q W n/ LL o <z o r�W �z CO m c' 0o W 3z O Q LLJ w H W c>o �w _o mk 03 LEGEND & SYMBOLS � ❑ SCOPE OF WORK: APPLICABLE CODES N= NOTES: WOOD FRAMED WALLS WINDOW NUMBERS REQUIRED MEANS OF EGRESS AND FIRE PROTECTION SYSTEMS SHALL BE MAINTAINED DURING Year Year a 3 ACOUST. ACOUSTIC SPEC. SPECIFICATION CONSTRUCTION AND DEMOLITION,REMODELING OR ALTERATIONS TO THE BUILDING.BUILDING NEW MULTISTORY SELF STORAGE BUILDING International Building Code 2018 National Electrical Cade 202n a,o: ARCH.PROJECT NO: 22-66 INSPECTIONS STAFF SHALL APPROVE REVIEW OF ANY EXITING ALTERATIONS AS REQUIRED IN COORDINATE WITH BARNE T STRUCTURES BUILDING International Mechanical Code 2018 Uniform Code for o'w ADJ. ADJUSTABLE STL. STEEL w DATE:12/21/2022 CONCRETE IFC SECTION 3311.2 PLANS AND SPECS FOR BUILDING INTERIOR International Fuel Gas Code 2018 0 ALUM. ALUMINUM TJI. TRUSS JOIST Building Conservation N�/d o DRAWN BY: BRENT AUTOMATIC FIRE SPRINKLER,FIRE SUPPRESSION AND FIRE ALARM SYSTEMS WHEN TAKEN OUT 999 International Plumbing Code 9018 CER.TILE CERAMIC TILE W.C. REQUIRED O • ARE RRPIL,ME SYSTEM 9 LL'7 CHECKED BY: DOOR NUMBERS OF SERVICE ARE REQUIRED TO HAVE FIRE PROTECTION BUREAU NOTIFICATION AT International Fire Code 2018117 CONC. CONCRETE W.C. WATER CLOSET • ELECTRICAL,MECHANICAL AND PLUMBING SYSTEMS- ANSI 3 DESIGNED BY: ACOUSTIC TILE (801)-799-4150.THE DURATION OF TIME AND DATE MUST BE STATED TO INCLUDE THE DATE International Energy Guidelines ICC Al 17.1 CONT. CONTINUOUS U.N.O. UNLESS NOTED OTHERWISE SEE ENGINEERING DRAWINGS -w THE FIRE PROTECTION EQUIPMENT WILL BE PALCED IN SERVICE.AS REQUIRED IN IFC Conservation Code 2018 2009 9 DET. DETAIL DETAIL CHAPTER 33. • SITE WORK-COORDINATE WITH CIVIL PLANS 1, © COPYRIGHT VDG ARCHITECTS ELEV. ELEVATION GYPSUM BOARD NUMBER PROVIDE AND MINIMUM 2A10BC RATED FIRE EXTINGUISHER WITHIN 75'TRAVEL DISTANCE TO a a EXIST EX. EXISTING DETAIL ALL SPACES IN THE STRUCTURE ACLUDING DURING CONSTRUCTION SEE FLOOR PLANS). , EXP. EXPANSION SHEET ( ) DEFERRED SUBMITTAL LIST: o z DATE REVISION ALTERATION OR DEMOLITION IN THE FOLLOWING AREAS AS PER IFC CHAPTER 33: FLR. FLOOR P L PROPERTY LINE MASONRY/ EXISTING WALLS NUMBER .. AT EACH STAIRWAY ON ALL FLOOR LEVELS WHERE COMBUSTIBLE MATERIAL HAVE 1. ARE SPRINKLER DRAWINGS FOR THE BUILDING ARE TO BE SUBMITTED TO FIRE MARSHAL FOR a¢ F.D. FLOOR DRAIN FGE. FINISH GRADE ELEVATION ACCUMULATED uio GAL FOLLOWING GALVANIZED TBC. TOP OF CURB ELEVATION •• IN EVERY STORAGE AND CONSTRUCTION SHED RENEW AND APPROVAL PRIOR TO COMMENCING INSTALLATION.FIRE PERMITS SHALL IN z w ACCORDANCE WITH IFC 105.1.1-105.7.16.THE FOLLOWING ITEMS SHALL REQUIRE A SEPARATE GA. GAUGE TCE. TOP OF CONCRETE ELEVATION RIGID INSULATION SECTION •• ADDITIONAL PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED WHERE SPECIAL ARE PERMIT: w o GYP. BD. GYPSUM BOARD FFE. FINISH FLOOR ELEVATION LETTER SECTION OR HAZARDS EXIST INCLUDING,BUT NOT LIMITED TO,THE STORAGE AND USE OF FLAMMABLE A. UNDERGROUND WATER MAINS,FIRE HYDRANTS,WET SYSTEMS SUPPLY z a INSULT. INSULATION —G— GAS LINE ELEVATION AND COMBUSTIBLE LIQUIDS. B. AUTOMATIC FIRE SPRINKLER AND STANDPIPE SYSTEMS o MAX. MAXIMUM SS SANITARY SEWER LINE WOOD C. AUTOMATIC FIRE ALARM SYSTEMS o DIMENSIONAL LUMBER SHEET MM MINIMUM W WATER LINE NUMBER D. EMERGENCY RESPONDER RADIO COVERAGE MTL. METAL —T— TELEPHONE LINE ol ow SHEET TITLE N. I. C. NOT IN CONTRACT P POWER LINE NOTE:ALL FIRE DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED WITHIN A TIMELY MANNER(30 DAYS - OPN'G OPENING FROM ORIGINAL PERMITTING DATE.)THE FINAL INSPECTION APPROVAL(IBC 110.3.10)CANNOT BE o�_ REINF. REINFORCED ISSUED AND NO BUILDING OR STRUCTURE CAN BE USED OR OCCUPIED(IBC 111.1)UNTIL ALL FIRE w T 1 . 0 SHT. SHEET DEFERRED SUBMITTAL ITEMS ARE APPROVED BY THE BUILDING AND FIRE OFFICIALS o zo O.C. ON CENTER a a ARCHITECTURAL -