Loading...
HomeMy WebLinkAboutCity of Twin Falls - Inspection Results Mike Plane From:cityworks@tfid.org Sent:Wednesday, February 15, 2023 14:22 Subject:City of Twin Falls - Inspection Results \[EXTERNAL SENDER\] DO NOT RESPOND TO THIS EMAIL, this is an outgoing email address only. Please respond directly to the inspector listed below if you have questions, comments or concerns. An inspection was performed today for: Permit #: 21-4998 Address: 214 CHENEY DR Inspection Type: Shear Wall Inspection Inspection Result: FAIL Inspector Comments: John 749-7514 Please follow all blocking and nailing called out in shear wall schedule detail 2/S6.01 (nail patterns, 3x blocking, SDS to top plate connections, etc.), install missing OSB rip pieces in shear wall (not concerned about fur down cripple walls above canopy area, but do need it installed in the actual shear walls), over driven nails into OSB shear walls need to be re-nailed (1/16" over driven okay-deeper needs to be re-nailed), some HD"s are missing and some nuts are not installed on HD's, please note there is a lot of drag struts and other connections designed that we will inspect at framing inspection. Due to this being a Category IV building, we will need to follow the engineered design very closely. Inspector: Jarrod may be contacted at jbordi @tfid.org For re-inspections, please call the inspection line or log into the Public App (tfid.org) Building: 208-735-7333 Electrical: 208-735-7235 Mechanical: 208-735-7289 Plumbing: 208-735-7299 Thank you, City of Twin Falls Building Department 1