VISTA RIM SUBDIVISION (SEWER)bedding insp mh s1 to mh s2 07-26-22 (002)
ISPWC DAILY INSPECTION REPORT "%-j 4{ect Name: Vista Rim Subdivision - Twin Falls, Id. Weather: Sunny, 930 F. Date: 07-20-22 Job No.: 299-20 EHM Representative: C. Earl Contractors Name: IEC Contractors Representative: Derek Area of Inspection: ❑ Water Line ® Sewer Line ❑ Storm Sewer ® Pressure Irrigation ❑ Streets ❑ Gravity Irrigation Inspection and/or Testing Details: Pipe Diameter: ❑ 2" ❑ 4" ❑ 6" ® 8" ❑ 10" ❑ 12" ❑ 16" ❑ 18" ❑ 24" ❑ 27" ❑ 32" ❑ 48" Pipe Type: PVC Pipe Class: ❑ C-900 ® SDR-35 ® C-200 >epth: 42" (36" Minimum) ® Tracer Wire Observed © Yes ❑ No M Pipe Bedding Inspection: In Conformance: ® Yes ❑ No Bedding Type: ® I ❑ III iJ Thrust Block Inspection: In Conformance: ❑ Yes ❑ No ❑ Pressure Test Observed: In Conformance: ❑ Yes ❑ No Deflection: ❑ Yes ® No Density Testing Item: ❑ Trench ❑ Subgrade ❑ Base ❑ Asphalt ❑ Utility Trench ❑ Concrete Testing Item: ❑ Sidewalk ❑ Curb & Gutter ❑ Valley Gutter ❑ Approaches Specific Location of Inspection and/or Testing from approved plans: Sewer line bedding inspection — Existing ESI Manhole to MH S1 Reviewe y: William J. Nenno, C.E.T. 621 North College Road -Suite 100 I y Twin Falls, Idaho 83301 El "' , _ _ ~ ; Inc. Ph. 208-734-4888 Fax 208-734-6049 ISPWC DAILY INSPECTION REPORT Project Name: Vista Rim Subdivision - Twin Falls, Id. Weather: Sunny, 820 F. Date: 07-23-22 Job No.: 299-20 EHM Representative: C. Earl Contractors Name: IEC Contractors Representative: Derek f rea of Inspection: ❑ Water Line M Sewer Line ❑ Storm Sewer M Pressure Irrigation ❑ Streets ❑ Gravity Irrigation Inspection and/or Testing Details: Pipe Diameter: ❑ 2" ❑ 4" ❑ 6" ® 8" ❑ 10" ❑ 12" ❑ 16" ❑ 18" ❑ 24" ❑ 27" ❑ 32" ❑ 48" Pipe Type: PVC Pipe Class: ❑ C-900 ® SDR-35 IN C-200 Pipe Depth: 42" (36" Minimum) 1 ,ai;er Wire Observed ® Yes ❑ No ® Pipe Bedding Inspection: In Conformance: M Yes ❑ No Bedding Type: ® I ❑ III ❑ Thrust Block Inspection: In Conformance: ❑ Yes ❑ No ❑ Pressure Test Observed: In Conformance: ❑ Yes ❑ No Deflection: ❑ Yes ® No ❑ Density Testing Item: ❑ Trench ❑ Subgrade ❑ Base ❑ Asphalt ❑ Utility Trench L Concrete Testing Item: ❑ Sidewalk ❑ Curb & Gutter ❑ Valley Gutter ❑ Approaches Specific Location of Inspection and/or Testing from approved plans: Sewer line bedding inspection — MH S1 to MH S2 Reviewed By: William J. Nenno, C.E.T. College Road -Suite 100 Twin Falls, Idaho 83301 " E, IM Engineers, Inc. BUILDING THE FUTURE ON AF f,�t��iDATION OF EXCELLENCE Ph. 208-734-4888 Fax 208-734-6049