23-1818 638 4th Ave E-Jarus, Seth - PV Plans (1)-Solar
ROOF MOUNT PHOTOVOLTAIC SYSTEM CODES: CONSTRUCTION NOTES: THIS PROJECT COMPLIES WITH THE FOLLOWING: "2018 INTERNATIONAL RESIDENTIAL CODE, PARTS I-VI AND IX," CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND "APPENDICES A, B AND G (WITH STATE AMENDMENTS)." ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 2018 INTERNATIONAL ENERGY CONSERVATION CODE (WITH ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT IDAHO STATE AMENDMENTS) POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE 2017 NATIONAL ELECTRICAL CODE (WITH STATE AMENDMENTS) MOUNTED. 2017 IDAHO STATE PLUMBING CODE MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN AS ADOPTED BY CITY OF TWIN FALLS ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER AS ADOPTED BY CITY OF TWIN FALLS (ID) SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. DIG ALERT (811)TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH VICINITY MAP: REQUIREMENTS OF ART. 690 OF THE 2017 NEC THE MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR LIFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVATION OF THE SOLAR PV SYSTEM ,f'��' NfitM1Ave ►cal Hears anyP\\\\ A ` SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY)AND UL 1741 STANDARDS CLIENT. QEconomy Locksmthing SETH JARUS Tw FaIlsPolice INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT 6384TH AVE E,TWIN FALLS,ID 83301 Cartridge World_ ®Department AHJ:CITY OF TWIN FALLS(D) ATTACHED TO THE ROOF USING CONDUIT MOUNT. sz Bare skinBrond sthAv F UTILITY:IDAHO POWER(ID) If2nd South Market P and Body m — PHONE:(402)440-6096 3 EMAIL:SHJARUS@HOTMAIL COM cT` m Jasmine Thai Cuisine msl'Don9"t 's,P Twin Falls Midwifery FINANCE: OTHER Ortler UseGlvelO t. O Hai \Kiba Studios �q„of Twin Falls K,baStudlos m T n Falls,ID \__j, 4th Ave E 4th Ave E 10Q eBickel Ele L.n The BarberSho,C \\ SYSTEM: Gehrig,Dale&C0Q SYSTEM SIZE(DC):11 X 410=4.510 kW s5 \ Truck RanchTwmFail,\ SYSTEM SIZE RE SO kW R C41 to �U4 dTraoks MODULES:11 X REC SOLAR:REC410AA 'vo 9e 4y In Twin Falls and Av E kre O'sHardwareq \ PURE-R \\ Vacuum Cleaners ward Mobile c OPTIMIZERS:11 REDGE E 380 P-U 505 INVERTER:SOLAREDGE SE3800H-USRGM Vape AJe� mOke Shop Of ldahoRepairB RV M [Sill A, y ® MAnigos Eatery aPioneer Trailer Park© SITE LOCATION TABLE OF CONTENTS: PV-1 SITE LOCATION REVISIONS PV-2 SITE PLAN NO. REVISED BY DATE PV-2A ROOF PLAN WITH MODULES LAYOUT PV-213 ROOF AND STRUCTURAL TABLES PV-3 MOUNTING DETAILS PV-4 THREE LINE DIAGRAM freedom EVER PV-5 CONDUCTOR CALCULATIONS FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, PV-6 EQUIPMENT&SERVICE LIST CA92590 Tel:(800)385-1075 PV-7 LABELS GREG ALBRIGHT PV-7A SITE PLACARD PV-8 OPTIMIZER CHART PV-9 SAFETY PLAN CONTRACTOR LICENSE: ELECTRICAL CONTRACTOR 053157 PV-10 SAFETY PLAN APPENDIX MANUFACTURER SPECIFICATION SHEETS SITE LOCATION JOB NO: DATE: DESIGNED BY: SHEET: 349274 7/17/2023 B.R. PV-1 LEGEND: ® CHIMNEY O PIPE VENT U MODULES CONDUIT FENCE ROOF LINE ® SETBACK PROPERTY LINE [AC] AC DISCONNECT [JB] JUNCTION BOX FINV INVERTER MSP MAIN SERVICE RIVEWAY PANEL ROOF AREA:2500 SO FT CLIENT: (N)JUNCTION BOX SETH JARUS 638 4TH AVE E,TWIN FALLS,ID 83301 (N) 11 REC SOLAR: REC410AA PURE-R AHJ:CITY OF TWIN FALLS(ID)UTILITY:IDAHO POWER(ID) PHONE:(402)440-6096 EMAIL:SHJARUS@HOTMAIL.COM FINANCE: OTHER JB SYSTEM: SYSTEM SIZE(DC):11 X 410=4.510 kW SYSTEM SIZE(AC):3.800 kW @ 240V MODULES:11 X REC SOLAR:REC410AA PURE-R OPTIMIZERS:11 X SOLAREDGE P505 INVERTER:SOLAREDGE SE380OH-USRGM [Sill �5Q J� (N)SOLAREDGE SE380OH-USRGM [SI1] REVISIONS NO. REVISED BY DATE (N) EATON DG221 NRB (OR EQUIVALENT) (E) MAIN SERVICE PANEL (E) UTILITY METER freedom F O R E V E R FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT > CONTRACTOR LICENSE: ELECTRICAL CONTRACTOR 053157 SITE PLAN 1 SCALE: 2/25" — 1'-0" SITE PLAN �3492704 BN :T7/17/2023 DATE: DESIGNED BY: SHEET:B.R. PV-2 LEGEND: TOTAL ROOF AREA: 2500 SQ FT TOTAL ARRAY AREA: 229.01 SQ FT CHIMNEY ARRAY COVERAGE: 9.16% SYSTEM DISTRIBUTED WEIGHT: 2.28 LBS O PIPE VENT ROCKIT SMART SLIDE POINT-LOAD: 27.45 LBS M MODULES u CONDUIT ® SETBACK 6' O% AC AC DISCONNECT FJB] JUNCTION BOX INV INVERTER FIRE ACCESS MSP MAIN SERVICE PATHWAYS PANEL ROOF AREA:2500 SO FT Q CLIENT: 3' SETHJARUS 638 4TH AVE E,TWIN FALLS,ID 83301 AHJ:CITY OF TWIN FALLS(ID) UTILITY:IDAHO POWER(ID) PHONE:(402)440-6096 EMAIL:SHJARUS@HOTMAIL.COM FINANCE: OTHER FIRE ACCESS Ea SYSTEM: PATHWAYS SYSTEM SIZE(DC):11 X 410=4.510 kW SYSTEM SIZE(AC):3.800 kW @ 240V MODULES:11 X REC SOLAR:REC410AA PURE-R OPTIMIZERS:11 X SOLAREDGE P505 INVERTER:SOLAREDGE SE380OH-USRGM [Sill 0 REVISIONS NO. REVISED BY DATE freedom F O R E V E R FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT > CONTRACTOR LICENSE: ELECTRICAL CONTRACTOR 053157 NOTES: ROOF PLAN 1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES SCALE: 2/25" _ V-10" 3. JUNCTION BOX IS MOUNTED TO THE RAIL. ROOF PLAN WITH MODULES LAYOUT OB DATE: DESIGNED BY SHEET: /17/2023 1 B.R. PV-2A ROOF DETAILS: TOTAL ROOF AREA: 2500 SQ FT TOTAL ARRAY AREA: 229.01 SQFT ARRAY COVERAGE: 9.16% SYSTEM DISTRIBUTED WEIGHT: 2.28 LBS ROCKIT SMART SLIDE POINT-LOAD: 27.45 LBS CLIENT: ROOF AREA STATEMENT SETHJARUS 638 4TH AVE E,TWIN FALLS,ID 83301 ROOF MODULE QUANTITY ROOF PITCH ARRAY PITCH AZIMUTH ROOF AREA ARRAY AREA AHJ:CITY OF TWIN FALLS(ID) UTILITY:IDAHO POWER(ID) ROOF 1 11 25 25 134 25 SQ FT 229.01 SQ FT PHONE:(402)440-6096 EMAIL:SHJARUS@HOTMAIL.COM ---- ---- ---- ---- ---- SQ FT SQ FT FINANCE: OTHER ---- ---- ---- ---- ---- SQ FT SQ FT ---- ---- ---- ---- ---- SQ FT SQ FT SYSTEM: ---- ---- ---- ---- SQ FT SQ FT SYSTEM SIZE(DC):11 X 410=4.510 kW SYSTEM SIZE(AC):3.800 kW @ 240V SQ FT SQ FT MODULES:11 X REC SOLAR:REC410AA ---- ---- ---- ---- PURE-R OPTIMIZERS:11 X P505 ---- ---- ---- ---- ---- SQ FT SQ FT INVERTER:SOLAREDGE SED380OH-USRGM [Sill ---- ---- ---- ---- ---- SQ FT SQ FT ---- ---- ---- ---- ---- SQ FT SQ FT ---- ---- ---- ---- ---- SQ FT SQ FT REVISIONS NO. REVISED BY DATE freedom i iv r v e a FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT �� �tE CONTRACTOR LICENSE: ELECTRICAL CONTRACTOR 053157 ROOF DETAILS JOB NO: DATE: I DESIGNED BY: SHEET: 349274 7/17/2023 B.R. PV-2B F-_ _ _ _ =� I I TABLE 1-ARRAY INSTALLATION II III III III III II II III III III III II MAX MAX RAIL - - ROOF MAX UNBRACED RAFTER/TRUSS PENETRATION ATTACHMENT PITCH ROOFING TYPE ATTACHMENTTYPE FRAMINGTYPEI LENGTH(FT.)1 SISTERING PATTERN2 SPACING OVERHANG(I Ili �I (IN.)2 N )3 II III III III III II II III III III III II ECOFASTEN ROCKIT SMART ROOF 1 25 COMP SHINGLE SLIDE 2X6 RAFTER @ 24"OC 12.00' NOT REQ'D STAGGERED 72"OC 24" STACKED DETAIL For Illustration purposes only IF--= r= _�Ilj_ _- I I u lu uu uu m u II III IIII IIII III II F-= �= 11 = = _11 1.CONTRACTOR TO VERIFY FRAMING TYPE AND MAX UNBRACED LENGTH PRIOR TO INSTALLATION.IF THE ABOVE INFORMATION DOES NOT MATCH FIELD CONDITIONS,NOTIFY ENGINEER OF RECORD IMMEDIATELY. I I 2.WHERE COLLAR TIES OR RAFTER SUPPORTS EXIST,CONTRACTOR SHALL USE RAFTERS WITH COLLAR TIES AS ATTACHMENT POINTS. II III IIII IIII III II II III IIII Dill III II 3.WHERE APPLICABLE FOR RAILED ATTACHMENT INSTALLATIONS. L_- — — A =J CLIENT: SETHJARUS 638 4TH AVE E,TWIN FALLS,ID 83301 AHJ:CITY OF TWIN FALLS(ID) UTILITY:IDAHO POWER(ID) PHONE:(402)440-6096 EMAIL:SHJARUS@HOTMAIL.COM STAGGERED DETAIL FINANCE: OTHER For Illustration purposes only SYSTEM: SYSTEM SIZE(DC):11 X 410=4.510 kW SYSTEM SIZE(AC):3.800 kW @ 240V MODULES:11 X REC SOLAR:REC410AA PURE-R OPTIMIZERS:11 X SOLAREDGE P505 INVERTER:SOLAREDGE SE380OH-USRGM [Sill a ROCKIT MOUNT ROCKIT MOUNT ROCKIT MOUNT ' X REC SOLAR: Z REC410AA REC SOLAR: REC410AA PURE-R PURE-R REC SOLAR:REC410AA PURE-R ROOF SURFACE ROOF MEMBRANE ROOF REVISIONS SKIRT MEMBRANE NO. REVISED BY DATE VARIES 2"MIN.EMBED. 2" N.EMBED. - - - 2X6 RAFTER @ 24"O.C. - MSN.EMBED' 2x#12 WOOD SCREW freedom 2 WITH 2"MIN.EMBEDMENT 2 x#12 WOOD SCREW AND FLAT WASHER WITH 2"MIN.EMBEDMENT FREEDOM FOREVER LLC AND FLAT WASHER 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 2 x#12 WOOD SCREW Tel:(800)385-1075 WITH 2"MIN.EMBEDMENT AND FLAT WASHER GREG ALBRIGHT � U �tE CONTRACTOR LICENSE: ELECTRICAL CONTRACTOR 053157 SOLAR PV ARRAY SECTION VIEW ATTACHMENT DETAIL Scale: NTS Scale: NTS MOUNTING DETAILS r3492704 B N : DATE: DESIGNED BY: SHEET: 7/17/2023 1 B.R. PV-3 BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 16.00A @ 240V 16.00 1XI 1.25 1 120AMPS 120A FUSES-OK CLIENT: SETHJARUS 638 4TH AVE E,TWIN FALLS,ID 83301 AHJ:CITY OF TWIN FALLS(ID) (E)1OOA RATED UTILITY:IDAHO POWER(ID) MAIN SERVICE PANEL PHONE:(402)440-6096 1 PH,120/240V 60HZ EMAIL:SHJARUS@HOTMAIL.COM (E)100A/2P MAIN (E)UTILITY FINANCE: OTHER BREAKER METER (TOP FED) SYSTEM: W STRING-1 U SYSTEM SIZE(AC):3.800 kW @ 240V 11 REC SOLAR:REC410AA PURE-R MODULES:11 X REC SOLAR:REC410AA PURE-R OPTIMIZERS:11 X SOLAREDGE P505 (N)SOLAREDGE •� INVERTER:SOLAREDGE SE380OH-USRGM SE380OH-USRGM[Sill INVERTER (N)30A FUSED • [SI1] /�r^ AC DISCONNECT LISTED LI D CON TAP VIA UL SOLAREDGE P505 AC EATON D 221 EQUIVALENT) (OR • LISTED CONNECTOR POWER OPTIMIZERS WITH 20A FUSES, DC KNIFEBLADE,LOCKABLE,NEMA • 3R,UL LISTED • I �� 0.J o •" 1 ' TO UTILITY ♦ — I JUNCTION I I O��O •/ OVERHEAD L- I Box I .-. ------------------- --- ____ _________-_---_---_- - FEED ------------ RAPID NS 2-#10 AWG,PV WIRE SHUTDOWN I NO. REVISED REVISIONS DATE 1-#6 AWG IN FREE AIR OR 2-#10 AWG,THWN-2 SWITCH #10 AWG MUST BE IN EMT 1-#10 EGC,THWN-2 3-#10 AWG,THWN-2 3-#6 AWG,THWN-2 L———————————— - - - CONDUIT IN 3/4"OR 1-#10 EGC,THWN-2 1-#10 EGC,THWN-2 LARGER EMT CONDUIT IN 3/4"OR LARGER EMT IN 3/4"OR LARGER EMT CONDUIT CONDUIT freedom '.J FORE V ER FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT �� g�N— CONTRACTOR LICENSE: ELECTRICAL CONTRACTOR 053157 NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT THREE LINE DIAGRAM TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS JOB NO: DATE: DESIGNED BY: SHEET: 349274 7/17/2023 B.R. PV-4 WIRE SCHEDULE CLIENT: SETHJARUS STARTING ADJUSTMENT MAXIMUM 6384TH AVE E,TWIN FALLS,ID 83301 STARTING TEMPERATURE ADJUSTED AHJ:CITY OF TWIN FALLS(ID) RACEWAY CONDUCTOR AWG ALLOWABLE CURRENT CORRECTION FACTOR FOR CONDUCTOR CURRENT UTILITY:IDAHO POWER(ID) # EQUIPMENT QTY. WIRE AMPACITY @ 90°C FACTOR AMPACITY APPLIED TO MORE THAN 3 APPLIED TO PHONE:(402)440-6096 SIZE CONDUCTORS CONDUCTORS CONDUCTORS EMAIL:SHJARUS@HOTMAIL.COM 310.15(B)(16) IN RACEWAY 310.15(B)(2)(a) 310.15(B)(3)(a) @ 90°C IN RACEWAY FINANCE: OTHER 1 DC MODULE TO OPTIMIZER 2 10 40 11.05 1 1 40.00 13.81 2 DC OPTIMIZER TO JUNCTION BOX 2 10 40 15.00 1 1 40.00 18.75 3 DC JUNCTION BOX TO INVERTER 2 10 40 15.00 1 1 40.00 18.75 SYSTEM: SYSTEM SIZE(DC):11 X 410=4.510 kW 4 AC INVERTER TO AC DISCONNECT 3 10 40 16.00 1 1 40.00 20.00 SYSTEM SIZE(AC):3.800 kW @ 240V MODULES:11 X REC SOLAR:REC410AA 5 AC AC DISCONNECT TO POI 3 6 75 16.00 1 1 75.00 20.00 PURE-R OPTIMIZERS:11 X SOLAREDGE P505 INVERTER:SOLAREDGE SE380OH-USRGM [Sill REVISIONS ---- NO. REVISED BY DATE -_-__ freedom i iv r v e a FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, ---- CA 92590 Tel:(800)385-1075 ---- GREG ALBRIGHT ---- CONTRACTOR LICENSE: ELECTRICAL CONTRACTOR 053157 CONDUCTOR AMPACITY CALCULATIONS IN ACCORDANCE WITH NEC 690.8. CONDUCTOR CALCULATIONS JOB NO: DATE: DESIGNED BY: SHEET: 349274 7/17/2023 1 B.R. PV-5 OCPD SIZES: SERVICE LIST: 20A BREAKER NONE MATERIAL LIST: OTY. PART PART# DESCRIPTION 11 MODULES PV-117410 REC SOLAR:REC410AA PURE-R 11 OPTIMIZERS OPT-130-505 SOLAREDGE P505 POWER OPTIMIZER-FRAME MOUNTED MODULE ADD-ON 1 JUNCTION BOX RAC-260-049 60OVDC NEMA 3R UL LISTED JUNCTION BOX 2 ELECTRICAL ACCESSORIES EA-350-326 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(FEMALE) 2 EQUIPMENT ACCESSORIES EA-350-327 STAUBLI/MULTI-CONTACT MC4 CONNECTORS(MALE) 1 INVERTERS INV-120-388 SE380OH-US[Sill RGM 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN 1 MONITORING EQUIPMENT ME-180-502 SOLAREDGE CELL MODEM CLIENT: 1 DISCONNECTS EE-321-036 30A RATED 240VAC NEMA 3R UL LISTED SETH JARUS 638 4TH AVE E,TWIN FALLS,ID 83301 2 FUSES BR-330-020 20A FUSE 1 PH 240VAC AHJ:CITY OF TWIN FALLS(ID) 3 ELECTRICAL ACCESSORIES EA-350-113 IDEAL B-TAP 4/0-10 AWG UTILITY:IDAHO POWER(ID) 19 FITTINGS/ANCHORS RAC-265-034 ROCKIT SMART SLIDE PHONE: 44 EMAIL:SHJAJARUS@HO HOTMAIL.COM 21 FOOTINGS RAC-265-004 "MFG:ECO FASTEN,ROCKIT COMP COUPLING AL BLK,MFG SKU:2011021" FINANCE: OTHER 19 FITTINGS/ANCHORS RAC-265-002 "MFG:ECO FASTEN,ROCKIT COMP SLIDE AL BLK,MFG SKU:2011013" 4 FOOTINGS RAC-265-028 "MFG:ECO FASTEN,SKIRT AL BLK 35MM&40MM A80,MFG SKU:2099012" 3 FITTINGS/ANCHORS RAC-265-031 "MFG:ECO FASTEN,SKIRT END CAP PLS 35MM&40MM-A,MFG SKU:2099035" 11 RAILS RAC-265-018 "MFG:ECO FASTEN,FRAME MLPE MOUNT SS,MFG SKU:4011012" SYSTEM: 38 SCREW RAC-265-035 ROCKIT SCREW#12X3 SYSTEM SIZE(DC):11 X 410=4.510 kW SYSTEM SIZE(AC):3.800 kW @ 240V MODULES:11 X REC SOLAR:REC410AA PURE-R OPTIMIZERS:11 X SOLAREDGE P505 INVERTER:SOLAREDGE SE380OH-USRGM [SI1] REVISIONS NO. REVISED BY DATE freedom '.J FORE V ER FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT CONTRACTOR LICENSE: ELECTRICAL CONTRACTOR 053157 EQUIPMENT&SERVICE LIST JOB NO: DATE: DESIGNED BY:I SHEET: 349274 7/17/2023 1 B.R. PV-6 WARNING: "WARNING" NOTES: POWER • - OUTPUT DUAL POWER SOURCES 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 Y MARKINGS SHOWN HEREON. CONNECTION SECOND SOURCE IS PHOTOVOLTAIC2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: 1 • NOT RELOCATERATED • 16.00 AMPS A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. OVERCURRENT DEVICE. AC NORMALOPERATING VOLTAGE1 VOLTS B. RED BACKGROUND COLOR WHITE TEXT AND LINE 705.12(B)(2)(3)(b) WORK. C. ARIAL FONT. 690.54 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN SOLAR PV SYSTEM EQUIPPED THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. WITH RAPID SHUTDOWN 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO P�Pa�Eesa�� SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY 690.56(C)(1)(A) CLIENT: ELECTRICAL • K HAZARD SETHJARUS 6384TH AVE E,TWIN FALLS,ID 83301 TE _ ` • • AND • ` 1 1 AHJ:CITY OF TWIN FALLS(ID) UTILITY:IDAHO POWER(ID) ` ENERGIZED • 'EN POSITION. PHONE:(402)440-6096 BE EMAIL:SHJARUS@HOTMAIL.COM FINANCE: OTHER a 690.13 (B) PV • SYSTEM- SYSTEM DC MAXIMUM VOLTAGE: � , �� SYSTEM SIZE(DC):11 X 410=4.510 kW SYSTEM SIZE(AC):3.800 kW @ 240V DISCONNECTPV SYSTEM AC . . MODULES:11 X REC SOLAR:REC410AA PURE-R (� MAX RATED OUTPUT CURRENT • 1• OPTIMIZERS:11 X SOLAREDGE P505 Q RATED ' OUTPUT 16.00 •NT- •LLE- • - 1 [IN 1]INVERTER:SOLAREDGE SE380OH-USRGM CONVERTER:AC NORMAL OPERATING VOLTAGE - 240 VOLTS THE C 690.15,690.54 690.53 I I ARRAY RAPID SHUTDOWN SWITCH FOR • - INVERTER REVISIONS PV SYSTEM DC J/B NO. REVISED BY DATE 690.56(C)(3) L NEC 690.31(G)(3)&(4) fr@@d0�1 VOLTAGEMAXIMUM 480 - NING FREEDOM FOREVERLLCE� J L _ _ _J _ _ _ _ _ 43445 BUSINESS PCAA 9 DR0#11 O,TEMECULA, MAXIMUM CIRCUIT CURRENTPHOTOVOLTAIC POWER • ■ Tel:(800)385-1075 MAXDC-DC CONVERTER15A GREG ALBRIGHT OUTPUT CURRENT EVERY 10'ON CONDUIT AND ENCLOSURES CONTRACTOR LICENSE: ELECTRICAL CONTRACTOR 053157 LABELS rJOB NO:F7117120231 DATE: DESIGNED BY: SHEET: 349274 B.R. PV-7 CAUTION . POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH CLIENT: SETHJARUS DISCONNECTS AS SHOWN 638 4TH AVE E,TWIN FALLS,ID 83301 T AHJ:CITY OF TWIN FALLS(ID) UTILITY:IDAHO POWER(ID) PHONE:(402)440-6096 EMAIL:SHJARUS@HOTMAIL.COM FINANCE: OTHER SYSTEM: SYSTEM SIZE(DC):11 X 410-4.510 kW SYSTEM SIZE(AC):3.800 kW @ 240V MODULES:11 X REC SOLAR:REC410AA PURE-R OPTIMIZERS:11 X SOLAREDGE P505 INVERTER:SOLAREDGE SE380OH-USRGM Sill INVERTER EQUIPPED WITH RAPID SHUTDOWN AC DISCONNECT MAIN SERVICE PANEL UTILITY METER REVISIONS WARNING NO. REVISED BY DATE TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL freedom F G R E V E R FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT NOTES: t'-� �tE 1. NEC ARTICLES 690 AND 705 AND IRC SECTION R324 MARKINGS SHOWN HEREON. CONTRACTOR LICENSE: 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: ELECTRICAL CONTRACTOR 0s3157 A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. SITE PLACARD 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. JOB NO: DATE: DESIGNED BY: SHEET: 349274 7/17/2023 B.R. PV-7A 1 -10 11 -20 21 -30 31 -40 41 -50 51 -60 SOLAREDGE OPTIMIZER CHART 1 4TH AVE E 2 3 CLIENT: SETHJARUS 638 4TH AVE E,TWIN FALLS,ID 83301 AHJ:CITY OF TWIN FALLS(ID) UTILITY:IDAHO POWER(ID) PHONE:(402)440-6096 EMAIL:SHJARUS@HOTMAIL.COM FINANCE: OTHER 5 SYSTEM: El SYSTEM SIZE(DC):11 X 410=4.510 kW SYSTEM SIZE(AC):3.800 kW @ 240V MODULES:11 X REC SOLAR:REC410AA PURE-R OPTIMIZERS:11 X SOLAREDGE P505 6 INVERTER:SOLAREDGE SE380OH-USRGM [SI1] � P J� 7 REVISIONS NO. REVISED BY DATE 8 freedom 9 FOREVER FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT 10 > CONTRACTOR LICENSE: ELECTRICAL CONTRACTOR 053157 OPTIMIZER CHART JOB NO:F711712023 DATE: DESIGNED BY: SHEET: 349274 1 B.R. PV-8 SAFETY PLAN MARK UP KEY INSTRUCTIONS: 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. 4TH AVE E P PERMANENT ANCHOR 2. SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE&MAKE NOTES ON THE JHASHEET T TEMPORARY ANCHOR INCIDENT REPORTING: FL] INSTALLER LADDER INJURIES-CALL INJURY HOTLINE (855) 400-7233 FB JUNCTION / COMBINER BOX "If injury is life threatening, call 911 first THEN the Injury Hotline NON-INJURIES-USE MOBILE INCIDENT REPORTING Fs-1 STUB-OUT (Auto, Property Damage, Near Miss) SKYLIGHT o NO LADDER ACCESS (STEEP rse"", GRADE OR GROUND LEVEL LME -i L OBSTRUCTIONS) ❑ ti CLIENT: SETHJARUS ■ F RESTRICTED ACCESS 6384THAVE TTWINFALLS,ID83301 AHJ:CITY OF TWIN FALLS(ID) UTILITY:IDAHO POWER(ID) PHONE:(402)440-6096 NEAREST OCCUPATIONAL/INDUSTRIAL CLINIC: EMAIL:SHJARUS@HOTMAIL.COM CONDUIT FINANCE: OTHER NAME: ADDRESS: GAS GAS SHUT OFF SYSTEM: SYSTEM SIZE(DC):11 X 410=4.510 kW NEAREST HOSPITAL: H2O WATER SHUT OFF SYSTEM SIZE(AC):3.800 kW @ 240V MODULES:11 X REC SOLAR:REC410AA NAME: PURE-R OPTIMIZERS:11 X SOLAREDGE P505 O SERVICE DROP INVERTER:SOLAREDGE SE380OH-USRGM ADDRESS: ISI1) O SAFETY COACH CONTACT INFORMATION: POWER LINES NAME: PHONE NUMBER: BREAK AND WATER LOG REVISIONS NO. REVISED BY DATE ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE THIS LOG IS TO BE FILLED OUT ANY TIME THE TEMP EXCEEDS 90 DEGREES. THE CREW LEAD AND ROOF LEAD ARE RESPONSIBLE FOR ENSURING THIS IS PLAN FOR WORKING SAFELY. COMPLETED AND UPLOADED AT THE END OF EVERYDAY WHEN TEMPS EXCEED 90 DEGREES NAME SIGNATURE „ freedom NAME 0800HRS 0900HRS 1000HRS 1100HRS 1200HRS 1300HRS 1400HRS 1500HRS 1600HRS FREEDOM FOREVER LLC 43445 BUSINESS PARK DR#110,TEMECULA, CA 92590 Tel:(800)385-1075 GREG ALBRIGHT L�� A��— CONTRACTOR LICENSE: ELECTRICAL CONTRACTOR 053157 SAFETY PLAN DATE: TIME: JOB NO: DATE: DESIGNED BY: SHEET: 349274 7/17/2023 1 B.R. PV-9 JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access • Crew leader responsible for communication with the client: Heat Related Illness Prevention NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE • Ladders must be inspected before each use. 1 • Employees shall have access to potable drinking water that is (add as many as necessary by using additional sheets) • Extension ladders must be set up on a firm and level surface at • Client and public is excluded from work area by barricades (N/A, fresh, pure, and suitably cool. The water shall be located as a 4-to-1 rise to run angle(or 75 degrees)and the top must be Yes, No): close as practicable to the areas where employees are working. Define the Hazard: Method/steps to prevent incident: secured to the structure. Extension style ladders placed on Water shall be supplied in sufficient quantity at the beginning of uneven, loose or slippery surfaces must additionally have the Training and Pre-Job Safety Briefing the work shift to provide at least one quart per employee per base firmly anchored or lashed so the base will not slip out. • All employees onsite shall be made aware of the specific hazards hour for drinking for the entire shift. Employees may begin the • Extension ladders must be used with walk-through devices or of this project and review this HJA during a pre-job briefing, and shift with smaller quantities of water if they identify the location Define the Hazard: Method/steps to prevent incident: the ladder must extend 36"above the stepping off point. their signature indicates awareness of site conditions and the and have effective means for replenishment during the shift to • A-frame ladders must only be climbed with the ladder spreader plan to eliminate any hazards identified prior to and during the allow employees to drink on quart or more per hour. The bars locked in the open position;A-frame ladders shall not be project. frequent drinking of water shall be encouraged. climbed while in the closed position (ex, closed and used while • Shade shall be present when temperature exceeds 80 degrees leaned against a structure). • Crew leader(name/title): Fahrenheit. When the outdoor temperature in the work exceeds Define the Hazard: Method/steps to prevent incident: • Additional notes: 80 degrees Fahrenheit, employees shall have and maintain one • Crew member(name/title): or more areas with shade at all times. Mobile Equipment • New employees must be acclimatized. New employees will be • Only Qualified operators will operate equipment; operators must Crew member(name/title): monitored by their Crew Leader(site supervisor)for the first two maintain a certification on their person for the equipment being (2)weeks of employment or longer when necessary. Define the Hazard: Method/steps to prevent incident: operated. • Crew member(name/title): • Employees will be allowed and encouraged to implement • Type(s)of mobile equipment(Type/Make/Model): scheduled breaks during each shift. Employees must take • Crew member(name/title): cool-down breaks in the shade any time they feel the need to do • Qualified operator(s): so to protect them from overheating. Supervisors are • Crew member(name/title): REQUIRED to allow employees any break period they need Material Handling and Storage during high heat conditions. CLIENT: SETHJARUS • Materials will be staged/stored in a way that does not present a Airborne Contaminants: • Cool Vests are encouraged for all employees at all times during 638 4TH AVE E,TWIN FALLS,ID 83301 hazard to client, personnel or public. Materials stored on the • Asbestos-containing (Transite)piping (ACP)-Do not disturb periods of high heat. AHJ:CITY OF TWIN FALLS(ID) roof will be physically protect from failing or sliding off. move, drill, cut fracture, etc. • Identify the location of the closet Occupational/industrial ational/Industrial Clinic UTILITY:102)4 POWER(ID) p Y Y p g g ( ) Y p PHONE:(402)440-6096 • Asbestos-containing thermal insulation (ACI)and or Hospital in case a crew member becomes ill. EMAIL:SHJARUS@HOTMAIL.COM Fall Protection Asbestos-containing duct wrapping (ACW)-do not disturb, no FINANCE: OTHER • A site-specific plan for fall prevention and protection is required attic or crawlspace access is allowed if work to be performed What is the specific plan to provide and replenish sufficient water for prior to starting work and must remain onsite at all times until could cause exposure to personnel, client or public. all employees on site? work is complete; a fall rescue plan must be outlined and . If offsite replenish is necessary,where will you go to replenish discussed among the crew prior to work start. • If yes, list specific tasks and protection in place: water(location/address): SYSTEM: • First-person-Up (FPU) must install their anchor and connect SYSTEM SIZE(DC):11 X 410=4.510 kWSYSTEM SIZE(AC):3.800 kW @ 240V before any other task, including installing other anchors. The • Who will replenish the drinking water(name): MODULES:11 x REC SOLAR:REC41oAA Last-Person-Down (LPD) Y person on a roof must be the only PURER OPTIMIZERS:11 X SOLAREDGE P505 uninstalling fall protection. INVERTER:SOLAREDGE SE380OH-USRGM • FPCP(name and title): Restroom facilities [Sill • Employees shall have access to restroom facilities with • FPU and LPD (name and title): hand-washing stations. Use of onsite restroom is at the client's discretion (location is annotated below). If client does not give Electrical Safety permission, location of suitable restroom facilities with • The Electrical Qualified Person (EQP)is required onsite to hand-washing stations offsite will be provided.The onsite perform electrical work. supervisor will identify location and make arrangements to • All electrical work will be performed with equipment in an ensure all employees have access at any point. electrically safe condition (de-energized)unless approval has • Restroom facilities will be(circle one): Onsite-Offsite REVISIONS NO. REVISED BY DATE been granted prior to work. Weather and Environment • If Offsite, add location name and address: • Service drops and overhead electrical hazards will be indentified • The site supervisor shall forecast the weather conditions at the and protected from contact, as neccessary. job site, prior to crew arrival, in order to mitigate any hazards Incident Reporting Procedure • EQP(name and tile): associated with inclement weather(heat, cold,wind, rain, etc.) 0 Contact your Site Supervisor • The site supervisor will utilized a portable wind meter Name: freedom Public Protection (anemometer)to verify actual onsite wind conditions, by checking i iv r v e a • The safety of the Client and Public must be maintained at all at the ground and on any elevated work surface(ex, rooftop) Phone: FREEDOM FOREVER LLC times. prior to work start, at midday and prior to solar panel staging on a 43445 BUSINESS PARK DR#110,TEMECULA, 590 • The Client and the Public shall be prevented from entering the roof. . 80 9285- p g Contact our Manager Tel:(800)385-1075 work zone through the use of barriers and/or signage, as 0 Elevated work involving the moving or maneuvering of solar Name: GREG ALBRIGHT required. panels shall cease at 25mph (sustained wind)until wind • Company, Client and Public property shall be protected from subsides. Phone: falling objects. Forecasted weather maximum temp(degrees f): • Pets(including dogs)shall be secured by their owners prior to Contact your Site Supervisor CONTRACTOR LICENSE: work start. Name: ELECTRICAL CONTRACTOR 053157 • The Client should not leave pets,family members, or others in charge or care of Employees, Contractors, or Temporary Phone: Workers. With:Your full name, phone number, office location, brief description SAFETY PLAN Of what happen and when. JOB NO: DATE: DESIGNED BY: SHEET: 349274 7/17/2023 1 B.R. PV-10 FOR INSTALLATION REFERENCE ONLY SCAN QR CODE TO ACCESS REFERENCE LINK FREEDOM REFERENCES PV INSTALLATION REFERENCES NO ONO 62 . - NO NO .,NO ONO C■.. ` -�- `� to.-I � .■1 . ■� ■ ■ ■ VNIm IN .1 ir. %.NqL 01--m. I . . . INSTALL HOTLINE ENPHASE IQ8 SOLAREDGE HD WAVE TESLA INVERTER BATTERY INSTALLATION REFERENCES 0 Rl .171I.Itz f 0 -1111.00 lil 0 m SON m ON or ir No NO NO ON ME m NO IN ■ ■ ■ A-CL 0 0 No LZ ON . ' - •■ •. • �■ -'• Or. ram: ON: . 1 ON OL 1 icNo. NON .0 �f ■ TESLA POWERWALL 2 SHIFT/SELF CONSUMPTION SOLAREDGE ENERGY BANK SOLAREDGE LG RESU (BACKUP) TESLA POWERWALL+ (BACKUP) V1.1 REE ALPHA PURER 5ERIE5 REC 1', r SOLAR'S MOST TRUSTED REC .1¢' GENERAL DATA _tif 38 8830 25 • --v0 - 80 half-cut REC heterojunction cells with �d ----- ' 425 Cell type: lead-free,gapless technology 3.2mm solar glasswith anti-reflective surface treatment Glass: in accordance with EN 12150 t. i Backsheet: Highly resistant polymer black Frame Anodized (black)ALPHA 1 Junction box: 4-part,4 bypass diodes,lead-free - + P68 rated,in accordance with IEC 62790 noo noo P U R E R S E R I E S Connectors: Staubli MC4 PV-KBT4/KST4(4 mmz) in accordancewith IEC 62852,IP68 only when connected on 02 Cable: 4mm2 solar rdance with 50618 p `_�-"• � in accordance with EN 50618 "•"� ==� PRODUCT SPECIFICATIONS _ Dimensions: 1730 x 1118x 30 mm(1.93 m2) as sEl Weight: 21.5 kg f , 45 22.5 594 3 Origin: Made in Singapore I ' Measurements in mm {M ELECTRICAL DATA Product Code":RECxxxAA Pure-R CERTIFICATIONS Power Output-PMAx(Wp) 400 410 420 430 IEC61215:2016,IEC61730:2016,UL61730 Watt Class Sorting-(W) 0/+10 0/+10 0/+10 0/+10 IEC62804 PID IEC61701 Salt Mist Nominal Power Voltage-VH,pp(V) 48.8 49.4 50.0 50.5 IEC62716 Ammonia Resistance r F Nominal Power Current-IH,p,(A) 8.20 8.30 8.40 8.52 IS011925-2 Ignitability(EN 13501-1 Class E) Open Circuit Voltage-V°C(V) 58.9 59.2 59.4 59.7 IEC 62782 Dynamic Mechanical Load IEC61215-2:2016 Hailstone(35mm) Short Circuit Current-Isc(A) 8.80 8.84 8.88 8.91 IEC62321 Lead-freeacctoRoHSEU863/2015 Power Density(W/mz) 207 212 218 223 IEC 61730-2:2016 Fire Class C(as per UL790) �• 0 ISO 14001,IS0 9001,IEC 45001,IEC 62941 y� Panel Efficiency 20.7 21.2 21.8 22.3 I 7 Power Output-P..(Wp) 305 312 320 327 o�E E& C E �❑ takeiway takee-way WEEE-compliant �I Nominal Power Voltage-VMppM 46.0 46.6 47.1 47.6 <"" as-E,ee ,erycnngecneme O Nominal Power Current-Impp(A) 6.64 6.70 6.80 6.88 TEMPERATURE RATINGS" r ! Z Open Circuit Voltage-Vnr(V) 55.5 55.8 56.0 56.3 Nominal Module OperatingTemperature: 44°C( 2°C) Short Circuit Current-Isr(A) 7.11 7.16 7.20 7.24 Temperature coefficient ofPMAx: 0.24%/°C eraturecoefficientofV Values at standard test conditions(STC:air mass AM 1.5,irradiance 1000 W/m',temperature 25°C),based on a production spread with Temperature oc: -0.24%/°C tolerance of PM Voc&Isc 3%within one watt class.Nominal module operating temperature(NMOT:air mass AM 1.5,irradiance 800 W/m2, temperature 20°C,windspeed I m/s).*Where xxx indicates the nominal power class(Pmj at STC above. Temperature coefficient of lsc: 0.04%/°C 'The temperature coefficients stated are linear values COMPACT P PANEL - MAXIMUM RATINGS WARRANTY DELIVERY INFORMATION AWL Operational temperature: -40...+85°C Standard REC ProTrust Pa nets perpahet: 33 System volta e 1000V nstalledbyanREC No Yes Yes Panels er40ftGP/highcubecontainer: 858(26 pallets) 9 A PANEL CURRENT g ' Certified Solar Professional p - Test load(front): +7000Pa(713kg/m2)' Systemsize All 425kW 25-500kW Panels per 13.6mtruck: 924(28pallets) _ COMPATIBLE wu Test load(rear): -4000Pa(407kg/mz)' Product Warranty(yrs) 20 25 25 ol i Series fuse ratin : 25A Power Warranty(yrs) 25 25 25 g LaborWarranty(yrs) 0 25 10 LOW LIGHT BEHAVIOUR N IL 10Reverse current: 25A Typical low irradiance performance of module at STC: a, a 'See installation manual for, PowerinYearl 98% 98% 98% m Design load=Test load/1.5(safetyfactor) Annual Degradation 0.25% 0.25% 0.25% r of Power in Year25 92% 92% 92% a o The REC ProTrust Warranty is only available on panels purchased -- ---- ---- ----�---- `� ' ~ through an REC Certified Solar Professional installer.Warranty ou conditions apply.See www.recgroup.com for more details. a Irradiance(W/m') Po EXPERIENCE + Availablefrom: 430 wp 25YEAR P.o 223 %m W WARRANTY , FREE Founded in 1996,REC G roup is an international pion eering so[a r energy co m pa ny d edicated to em powering consu mers REC Solar PTE.LTD.with clean,affordable solar power.As Solar's Most Trusted,REC is committed to high quality,innovation,and a low 20 TuasSouth Ave.14 IJ` ■ COMPLIANT PERFORMANCE carbon footprint in the solar materials and solar panels it manufactures.Headquartered in Norway with operational Singapore 637312 ^�� �" headquarters in Singapore,REC also has regional hubs in North America,Europe,and Asia-Pacific. post@recgroup.com www.recgroup.com Power Optimizer ma For North America Power Optimizer P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 O ' (for higher- I P400 P405 P485 P505 For North America Optimizer model (typical module (for 60-cell power •'P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 •• 60-cell modules) cell modules .. modules) modules) modules) mINPUT Rated Input DC Powerni 320 350 370 400 405 485 505 W Absolute Maximum Input Voltage 48 60 80 60 125i2i 830 Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 8-60 8-80 8-60 12.5-105 12.5-83 Vdc O Maximum Short Circuit Current 11 11.02 (Isc) 11 10.1 11.75 11 14 Adc Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current1 15 Adc 41Maximum Output Voltage 1 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1±0.1 Vdc Optimizer STANDARD COMPLIANCE N EMC FCC Part15 Class 3,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 Material UL94 V-0,UV Resistant ROHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System 1000 Vdc Voltage Compatible inverters All SolarEdge Single Phase and Three Phase inverters 129x153x33.5 129x153x29.5 129x162x59 TrimDimensions(WxLxH) 129x153x27.5/5.1x6x1.1 /5.1x6x1.3 /5.1x6x1.16 129x159x49.5/5.1x6.3x1.9 /5.1x6.4x2.3 /in Weight(including cables) 630/1.4 1 750/1.7 655/1.5 845/1.9 1064/2.3 gr/It, Input Connector MC4(3) Single or dual MC4i3i MC4t3ii^i Input Wire Length 0.16/0.52 0.16 or 0.9 0.16/0.52 m/ft /0.52 or 2,95(,) Output Wire Type/Connector Double Insulated/MC4 Output Wire Length 0.9/2.95 1.2/3.9 m/ft PV power optimization at the module-level Operating Temperature Rangers 40to+85/-40to+185 -C/-F Protection Rating IP68/Type 6P Relative Humidity 0-100 % Specifically designed to work with SolarEdge Fast installation with a single bolt (1)Rated power of the module at STC will not exceed the optimizer"Rated Input DC Power".Modules with up to+5%power tolerance are allowed (2)NEC 2017 requires max input voltage be not more than 80V inverters (3)For other connector types please contact SolarEdge (4)For dual version for parallel connection of two modules use P485-4NMDMRM.In the case of an odd number of PV modules in one string,installing one P485 dual version power optimizer connected to Next generation maintenance with module- one PV module.When connecting a single module seal the unused input connectors with the supplied pair of seals U to 25% more energy level monitoring (S)Longer inputs wire length are available for use.For 0.9m input wire length order P401-xxxLxxx p gY (6)For ambient temperature above+85°C/+1857 power de-rating is applied.Refer to Power Optimizers Temperature De-Rating Technical Note for more details Superior efficiency (99.5%) / Meets NEC requirements for arc fault DesignPV System _ . , Three Phase for protection (AFCI) and Photovoltaic Rapid SolarEdge Mitigates all types of module mismatch losses, Shutdown System PVRSS P320,P340,P370, Y ( ) Minimum String Length P400,P401 8 10 18 from manufacturing tolerance to partial (Power Optimizers) P405,P485,P505 6 8 14 shading / Module-level voltage shutdown for installer Maximum String Length(Power Optimizers) 25 25 50t9i and firefighter safety 5700(6000 with Flexible system design for maximum space Maximum Power per String SE7600-US-SE11400- 5250 600000) 12750(") W us> utilization Parallel Strings of Different Lengths or Orientations Yes (7) For detailed string sizing information refer to:http://www.solaredge.com/sites/default/files/string_sizing-na.pdf (8)It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (9)A string with more than 30 optimizers does not meet NEC rapid shutdown requirements;safety voltage will be above the 30V requirement (10)For 208V grid:it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W (11)For 277/480V grid:it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W solaredge.com solar L S ttrtra Technologies Ltd.All rights reserved.rks SOLAREDGE,the SolarEdge logo,OPTIMIZED BY 000044SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc. C�� . Ron S AlCIS, other trademarks mentioned herein are trademarks of their respective owners.Date:12/2021 DS-000044-1.3-NA.Subject to change without notice. Intertek / Single Phase Inverter with HD-Wave Technology SingleforNorth America Phase Inverter zSE3000H—US / SE3800H—US / SE5000H—US / SE6000H—US/ • < SE7600H—US / SE10000H—US / SE11400H—US with HID-Wave Technology m .. ,,, ,,, ,,., for North America APPLICABLE TO INVERTERS SEXXXXH-XXXXXBXX4 X WITH PART NUMBER SE3000H—US / SE380OH—US / SE5000H—US / SE6000H—US / OUTPUT S E7600 H—U S / S E 10000 H—U S / S E 11400 H—U S Rated AC Power output 3000 3800 @ 208V Soon 5000 @ 208V 7600 10000 10000 @ 208V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @240V VA 3300 @ 208V 5000 @ 208V 10000 @208V 12-25 AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac YEAR (211-240-264) O AC Output Voltage Min. Nom. Max. ✓ i ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.5r) Hz Maximum Continuous Output Current @240V 2.5 16 21 25 32 42 47.5 A Maximum Continuous Output - 16 24 48.5 A Current @208V O Power Factor 1,Adjustable-0.85 to 0.85 0 O GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT solar,-!'[s _HD... solar�i a_,1 Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W 0 O A Maximum DC Power @208V - 5100 7750 15500 W . rX Transformer-less,Ungrounded Yes O O Maximum Input Voltage 480 Vdc O a _ Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V" 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V" 9 13.5 27 Adc Max.Input Short Circuit Current 45 Adc 0 q p 4 Reverse-Polarity Protection Yes ' W Ground-Fault Isolation Detection 600kQ Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency gg 99 @240V % 98.5 @ 208V Nighttime Power Consumption <2.5 W Optimized installation with HD—Wave technology 1)For other regional settings please contact SolarEdgesupport (2)A higher current source may be used;the inverter will limit its input current to the values stated / Specifically designed to work with power optimizers / UL1741 SA certified,for CPUC Rule 21 grid compliance / Record-breaking 99%weighted efficiency / Small, lightweight, and easy to install both outdoors or indoors / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Optional: Faster installations with built-in consumption metering (1%accuracy) and / Integrated arc fault protection and rapid shutdown production revenue grade metering (0.5%accuracy, for NEC 2014, NEC 2017 and NEC 2020 per article ANSI C12.20) 690.11 and 690.12 solaredge.com solar=es / Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE1000OH-US / SE1140OH-US MODEL ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Metering,ANSI C12.20 Consumption metering Optionall3 Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown-NEC 2014,NEC Automatic Rapid Shutdown upon AC Grid Disconnect 2017 and NEC 2020,690,12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL169913,CSA C22.2,Canadian AFCI according to TLL.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG DC Input Conduit Size/#of Strings/ T'Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/mm Weight with Safety Switch 22110 1 25.1/11.4 1 26.2/11.9 38.8/17.6 lb/kg Noise <25 1 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+6014] T/-C Protection Rating NEMA 4X(Inverter with Safety Switch) (3)Inverter with Revenue Grade Meter P/N:SExxxxH-US000BNC4;Inverter with Revenue Grade Production and Consumption Meter P/N:SExxxxH-USOOOBNI4.For consumption metering,current transformers should be ordered separately:SEACT0750-20ONA-20 or SEACT0750-40ONA-20.20 units per box (4)Full power up to at least 50"C/122F,for power de-rating information refer to:https://w ..solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HID-wave technology and built-in RGIVI and Service Panel consumption monitoring o Grid __ CT Li IN L2 Shielded CAT5e cable ---- -------L1------- --------- ---� L2 AC Conduit ®SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All Ro H S other trademarks mentioned herein are trademarks of their respective owners.Date:12/2020N01/ENG NAM.Subject to change without notice. Physical Attributes Performance Ratings Product specifications Enclosure Amperage Rating NEMA 3R 30A Enclosure material Fuse class provision Eaton DG221 N RB Painted galvanized steel Class H fuses Fuse configuration Voltage rating Fusible with neutral 240V Number Of Poles Two-pole Miscellaneous Catalog •e RB Number of wires 3 Product Category General duty safety switch Eaton General duty cartridge fuse safety switch, 30 A, NEMA 3R, Red Type painted galvanized steel,Class H fuses, Fusible with neutral,Two-pole, General duty,cartridge fused Three-wire,Category:general duty safety switch,240 V General specifications Catalogs Eaton's Volume 2—Commercial Distribution Product Name Catalog Number Multimedia Eaton general duty cartridge fuse safety DG221 NRB Double Up on Safety switch UPC Switching Devices Flex Center 782113120317 Specifications and datasheets Product Length/Depth Product Height Eaton Specification Sheet-DG221NRB 6.88 in 10.81 in F.,T*N Product Width Product Weight Powering Business Worldwide 6.38 in 6 lb Warranty Certifications Eaton Selling Policy 25-000,one(1)year UL Listed from the date of installation of the Product or eighteen(18)months from the Catalog Notes date of shipment of the Product, Maximum hp ratings apply only when dual element fuses are used 3-Phase hp Eaton Corporation plc . whichever occurs first. Eaton House rating shown is a grounded B phase 30 Pembroke Road Eaton is a registered trademark. rating,UL listed. Dublin 4, Ireland 0000 Eaton.com �UmTeN All other trademarks are ©2023 Eaton.All Rights property of their respective Powering Business Worldwide Reserved. owners. Eaton.com/social media ® UListed L 486B Pressure Cable Connectors File No.E-5238 B-TAP° INSULATION PIERCING TAP CONNECTORS TORQUE AND BmrAP Suitable for use on the line CURRENT RATINGS side of the service equipment. INSULATION-PIERCING TAP CONNECTORS (Solid and/or Stranded) CONECTORES DE DERIVACION QUE PERFORAN EL AISLAMIENTO NOMINAL TAP CURRENT RATIING CATALOG# MAIN TAP TORQUE (IN BTC2/0-14 2/0-4 10-14+ 80 IN. LBS. 40 AMPS)* Installation Instructions: Instalacion Instrucciones: BTC1/0-10 1/0-8 2-10- 80 IN. LBS. 130 BTC4/0-10 4/0-3 2-10— 125 IN. LBS. 130 Improperly installed electrical wiring can be dangerous Los cables electricos mal instalados pueden ser peligrosos BTC4/0-6 4/0-2 1/0-6 160 IN. LBS. 170 and cause electrical fires.The connector chosen must y provocar incendios.El conector escogido debe ser de un BTC4/0-2 4/0-2 4/0-2 160 IN. LBS. 260 be sized to the wires being used.Consult local building \ tamano adecuado para los cables que se utilicen.Consulte BTC250-6 250-4 4/0-6 160 IN. LBS. 260 code before doing any electrical work.For assistance, los c6digos de construccion locales antes de efectuar trabajos refer to an instructional book or consult a qualified electricos.Si necesita ayuda,consulte un libro de instrucciones BTC250-4 250-1 3/0-4 160 IN. LBS. 225 electrician. o consulte con un electricista capacitado. BTC250-2 250-1/0 4/0-2 160 IN. LBS. 260 BTC350-1/0 350-1/0 350-1/0 330 IN. LBS. 350 warning ! Advertencia BTC500-4 500-2/0 4/0-4 330 IN. LBS. 260 Contact with electricity can cause serious injury or death. figure 1 Use solo en cable aislado.[RHH,RHW(-2),THHN,THHW,THW, BTC500-1/0 500-4/0 350-1/0 330 IN. LBS. 350 Use on insulated cable only.[RHH,RHW(-2),THHN, THWN,USE,XHHW(-2).Consulte con la fabrica para obtener THHW,THW,THWN,USE,XHHW(-2).Consult factory informacion sobre otros tipos de aislamiento].Si se va a hacer BTC500-14 750-3/0 10-14... 80 IN. LBS. 40 for other insulation types].If the installation is to be la instalacion sobre un cable con corriente el conductor derivado BTC750-250 750-250 500-250 330 IN. LBS. 430 made on an energized run,the tap conductor must debe estar libre de carga y no debe estar aterado.Use guantes be under no load and must not be grounded.Use +10-14 Cu SOLID/STRANDED;10-12 Al SOLID/STRANDED electrical) insulated gloves.De-energize the run cable if con aislamivaci el si no s Quite a la milli nee al cable del cual se y hace la derivacion si no se pueden cumplir estas condiciones.El ++2-10 Cu SOLID/STRANDED;2-10 Al STRANDED there are any questions of these conditions being met. ® contacto con electricidad puede producir lesiones graves o mortales. +++2-10 Cu SOLID/STRANDED;2-8 Al STRANDED ++++10-14 Cu SOLID/STRANDED;10-12 Al STRANDED 1. Determine the direction for the tap conductor to exit and . ►� 1. Determine la direccion en la que el conductor derivado saldra y Full line is 600V dual-rated,194°F(90°C) discard one end cap.See figure 1. deseche la tapa terminal sobrante.Vea la ilustracibn 1. 2. Position the main or feeder side of the connector around "Based on NEC Table 310-161996(Not more than 3 insulated conductors in a raceway at ambient temperature of 30°C)for the largest tap wire size. ( ) 2. Coloque el lado principal(o de alimentation)del conector the run cable and tighten the bolt finger tight.See alrededor del cual se hace la derivacion y apriete firmemente figure 2. If required,loosen the bolt slightly to allow the el dedo del perno.Vea la ilustraci6n 2.Si hace falta,afloje connector to open completely.DISASSEMBLY NOT el perno ligeramente para permitir que el conector se abra RECOMMENDED.The plastic'Turbo"spacer holds the figure 2 completamente.NO ES RECOMENDABLE DESARMAR EL connector open which eases installation and ensures proper CONECTOR. El espaciador'Turbo"de plastico mantiene al connections. conector abierto,Io cual facilita la instalacion y asegura que Ias 3. Cut the end of the tap cable squarely.DO NOT STRIP conexiones se hagan correctamente. CABLE INSULATION. 3. Corte el extremo del cable de derivacion perpendicularmente a su • eje.NO PELE EL AISLAMIENTO DEL CABLE. 4. Insert the tap cable into the tap side of the connector until it ® 4. Inserte el cable de derivacion en el lado de derivacion del is seated in the remaining end cap.See figure 3. conector hasta que tope contra la tapa terminal que queda.Vea la 5. Continue tightening the torque regulating bolt with a ilustraci6n 3. standard box or socket wrench until the torque regulating 5. Continue apretando este perno que regula la torsion con una piece breaks away.If the connector has two(2)assembly 1` Ilave estandar o de cubo hasta que la pieza que regula la torsion bolts,alternately tighten until the hexagonal torque devices se parta y se separe.Si el conector tiene dos(2)pernos de break away.See figures 4a&4b.Note that the plastic ensamblaje,apriotelos alternativamente hasta que el dispositivo "turbo"spacer on the side will also break.To make the de regulation de torcib se parta.Vea la ilustraci6n 4a y 4b. installation even easier and to relieve torque from the figure 3 Observe que el espaciador"turbo"de plastico en el costado cables,a second wrench can be used or the hexagonal tambien se fracturara.Para hacer esta instalacion a6n mas facil y piece the bottom of the connector. para aliviar la torsion de los cables,se puede usar una.segunda (lave sobre la pieza hexagonal al fondo del conector. DO NOT use gripping type pliers, pipe,open ended NO USE alicates de presi6n, (laves de turbo, (laves WARNING:Cancer and Reproductive Harm-www.P65Warnings.ca.gov. or adjustable wrenches as these may damage the 1 y 9 comunes o ajustables ya que estas pueden donor el LiT601162., hexagonal torque regulating device.A torque wrench is not 0 dispositivo hexagonal que regula la torsion.No se requiere una ZEADVERTENCIA:Cancer y Dana Reproductivo-www.P65Warninas.ca.aov. required. ® Ilave de torsion. MAKE SURE ONLY THE TOP HEXAGONAL TORQUE ASEGORESE DUE SE USE, PARA EL ENSAMBLADO, 1800 S.Prairie Drive DEVICE OF THE BOLT HEAD IS USED FOR SOLO EL DISPOSITIVO SUPERIOR DE REGULAC16N DE One year limited warranty.See idealind.com for more information. Sycamore,IL,U.S.A. ASSEMBLY. THE SECOND HEX PIECE [CLOSER TORSION DE LA CABEZA DEL PERNO. LA SEGUNDA 800-435-0705•www.idealind.com TO THE BODY OF THE CONNECTOR] IS USED FOR Before After correct PIEZA HEXAGONAL(LA MAS CERCANA AL CUERPO Garantra limitada de un ano.Visite www.idealind.com para obtener detalles de la garantfa. DISASSEMBLY. Torque Torque Reached, DEL CONECTOR)SE USA SOLO PARA DESARMAR EL Applied One Piece CONECTOR. Note:The torque regulating bolt ensures the correct torque y Nota:El perno regulador de torsion garantiza la aplicacion de la is applied to the conductors without using a torque wrench. figure 4a figure 4b torsion correcta a los conductores sin usar una Ilave de torsion. No 9053-2 Important information such as run and tap ranges,voltage La informacion importante de longitud de cable pelado y de toma, 1839420 ratings and material/temperature ratings is marked on the Ias clasificaciones de materiales y temperatura esta marcada en el connector. conector. • • • IOFq� I/yOIISN?IF� I/VC. D � ® 1375 Park Avenue•Sycamore, Illinois 60178•815.895.5181•www.idealind.com ALL IDEAL Customers 2/9/23 Subject: The Buchanan B-TAP° splice/tap connectors meet the 2020 NEC article 230.46 requirement for "line side applications" The Buchanan B-TAP° brand of insulation piercing connectors which correspond to part numbers beginning with "BTU meet the requirements of article 230.46 of the 2020 NEC. These products have already been tested to the newer requirements. The installation instructions are in the process of being updated to show the required notation: "suitable for use on the line side of the service equipment". This change will take a few weeks to get into our production. In addition, the marking "SR" will be added to the product. That addition is in process and will take a few months to complete. This notice will provide confirmation to the inspectors that B-TAP° products meet the requirements of the 2020 and 2023 NEC article 230.46 "Spliced and Tapped Conductors". Sushil Keswani Director of Engineering IDEAL Industries, Inc., ® Listed pressure cable connectors, Model(s): BHT1, BHT2, BHTS, BN1, BN2, BNS, BNT1-16, BNT14, BNT2-16, BNT22, BNT5-20, BNTB, U L Product iQ UL Solutions BNYDF1, BNYDF2, BNYDFS, BNYT1, BNYT2, BNYTS, BV1, BV2 BV5, BVT14, BVT22, BVT8 ZM WE5238 - Wire Connectors and Soldering Lugs Listed pressure ring terminal connectors, Model(s): RNYB14-8, RNYB8-11, RNYBL22-5, RNYBL22-6 Listed splicing w ire connectors, Model(s): L12, L13, L15 N cn-insulated flange spade crimp connectors, Model(s): FSN1-3.7, FSN1-4, FSN1-5, FSN2-3.7, FSN2-41 FSN2-5, FSN5-3.7, FSN5-4, FSN5-5, FSNB1-3.7, FSNB1-4, FSNB1-5, FSNB2-3.7, FSNB2-4, FSNB2-5, FSNB5-3.7, FSNB5-4, FSNB5-5, FSNL1-3.7, FSNL2-5 N de:We are enhancing our systems and you may notice duplicate entries/m&sing/outdated data.During this interim period,please contact our Customer Service athttps://www.ul.com/about/locations. Nrn-insulated hook crimpconnectors, Model(s): HN1-4, HN1-51 HN2-3.71 HN2-41 HN2 5, HN5-3.7, HN5-4, HN5-5 N cn-insulated locking type crim p connectors, Model(s): LSN1-3.7, LSN2-3.7, LSN5-3.7, LSN5-4, LSN5-5, LSN5-6, LSNL1-4, LSNL1-5, LSNL2-5 Wire Connectors and Soldering Lugs N an-insulated multiple stud ring type crimp connectors, Model(s): MSRNB1-3753 IDEAL IN DLISTRIES IN C E5238 N cn-insulated parallel crimp connectors, Model(s): PNT 1, PNT 14, PNT 2, PNT 22, PNT 5, PNT 8, PNT1, PNT2, PNTS 1375 Park Ave SYCAMORE, IL 60178 United States N cn-insulated pin type crimp connectors, Model(s): PTN1-12, PTN2-12, PTN5-13 View model for additional information N cn-insulated ring type crim p con nector, Model(s): RNB1-10, RNB1-3.2, RNB14-11, RNB14-12, RNB14-16, RNB1-6, RNB1-8, RNB2- Insulated butt splice crimp type connectors, Model(s): BVS1, BVS2, BVSS 10, RNB2-2, RNB2-6, RNB5-12, RNB8-12, RNBL1-4 Insulated flange spade type crimp cconnectors, Model(s):SV5-3.71 SVL5-4,SVL5-6 N cn-insulated ring type crimp connectors, Model(s): RNB1-3.2, RNB14-10, RNB14-5, RNB14-8, RNB1-5, RNB2-10, RNB22-10, RNB22-12, RNB22-8, RNB2-3.2, RNB2-8, RNB5-10, RNB5-3.2, RNB5-3.7, RNB5-3.7, RNB5-51 RNB5-6, RNB5-8, RNB8-101 RNB8-11, Insulated flange spade type crimp connectors, Model(s): FSNYD1-3.7, FSNYD1-4, FSNYD1-5, FSNYD2-3.7, FSNYD2-4, FSNYD2-5, RNB8-16, RNB8-8, RNBL1-3.7, RNBL22-5, RNBL22-6, RNBL2-3.7, RNBL2-5, RNBL38-10, RNBL5-3.7, RNBL5-4, RNBM 1-3.7, RNBM 1-3.7, FSNYD5-3.7, FSNYD5-4, FSNYD5-5 RNBM2-3.7, RNBM2-3.7, RNBM8-5, RNBS1-4, RNBS14-5, RNBS2-4, RNBS2-5, RNBS5-4, RNBS8-6 Insulated hook type crimp connectors, Model(s): HNYD1-3.7, HNYD1-4, HNYD1-5, HNYD2-3.7, HNYD2-4, HNYD2-5, HNYD5-3.7, N cn-insulated spade type crimp connectors, Model(s):SN1-3.2,SN2-3.2,SN5-3.7, SN5-5, SNB1-3.2, SNB5-3.7,SNB5-5,SNBL1-3.7, HNYD5-4, HNYD5-5, HVY1-3.7, HVY1-4, HVY1-5, HVY2-4, HVY2-5, HVY5-3.7, HVY5-4, HVY5-5 SNBL1-4,SNBL2-4,SNBL2-5,SNBL5-4, SNBL5-6,SNBLL1-3.7,SNBLL2-3.7,SNBM 1-4,SNBS1-5,SNBS5-4,SNL1-3.7,SNL1-4,SNL2-3.7, SNL2-4,SNL2-5,SNLL1-3.7,SNLL2-3.7,SNM 1-4,SNM2-4,SNS1-5,SNS2-5,SNS5-4 Insulated locking spade crim p connectors, Model(s): LSNYD1-3.7, LSNYD2-3.7, LSNYD5-3.7, LSNYD5-4, LSNYD5-5, LSNYDL1-4, LSNYDL1-5, LSNYDL2-4, LSNYDL2-5 Pressure cable connectors, Model(s): KB- 1000, KB-2/0, KB-350, KB-4/0, KB- 500, KB-800, KS- 1000, KS 2/0, KS-350, KS- 4/0, KS- 500, KS-800 Insulated multiple stud ring type crimp connectors, M odel(s): M SRNYD1-3753, M SRNYD2-3753, M SRNYD5-3753 Pressure terminal connectors, Model(s): FSVY1-3.7, FSVY1-4, FSVY1-5, FSVY2-3.7, FSVY2-4, FSVY2-5, FSVY5-3.7, FSVY5-4, FSVY5-5, Insulated parallel connectors, Model(s): PVT1, PVT14, PVT2, PVT22, PVTS, PVT8 K-5655, K-5656, LSV1-3.7, LSV2-3.7, LSV5-4, LSV5-5, LSV5-6, LSVL2-4, LSVS1-4, LSVS1-5, LSVS2-5, LSVY1-3.7, LSVY2-3.7, LSVY5-3.7, LSVY5-4, LSVY5-5, LSVY5-6, LSVYL1-4, LSVYL1-5, LSVYL2-4, LSVYL2-5, M SRN B2-3753, M SRVYl-3753, M SRVY2-3753, M SRVYS-3753, Insulated pin type connectors, Model(s): PTNYD1-12, PTNYD2-12, PTNYD5-13 PTVY1-12, PTVY2-12, PTVY5-131 RVY1-101 RVY1-5, RVY1-6, RVY1-8, RVY2-10, RVY2-2, RVY2-3.2, RVY2-6, RVY2-8, RVY5-10, RVY5-12, RVY5-3.2, RVY5-3.7, RVY5-5, RVY5-6, RVY5-8, RVYL1-3.7, RVYL1-4, RVYL2-3.7, RVYL2-4, RVYL2-5, RVYL5-3.7, RVYL5-4, RVYM 2-3.7, Insulated ring type crimp connectors, Model(s): RNYB14-11, RNYB22-11, RNYD1-10, RNYD1-3.2, RNYD1-5, RNYD1-6, RNYD1-8, RVYS1-3.7, RVYS1-4, RVYS2-3.7, RVYS2-4, RVYS2-5, RVYS5-4,SNBM2-4,SNYD2-3.2,TLK16-6,TLK25-10 RNYD2-10, RNYD2-2, RNYD2-3.2, RNYD2-6, RNYD2-8, RNYD5-10, RNYD5-12, RNYD5-3.2, RNYD5-3.7, RNYD5-5, RNYD5-6, RNYD5-8, RNYDL1-3.7, RNYDL1-4, RNYDL2-3.7, RNYDL2-4, RNYDL5-3.7, RNYDL5-4, RNYDM2-3.7, RNYDS1-3.7, RNYDS1-41 RNYDS2-4, RNYDS2- Pressure Terminal Connectors, Model(s): RNYB14-10, RNYB14-12, RNYB14-5, RNYB22-12, RNYB22-8, RNYB8-10, RNYB8-12, RNYB8- 5, RNYDSS-4, RV1-3.2, RV1-5, RV1-6, RV2-3.2, RV5-10, RV5-3.7, RV5-5, RV5-6, RV5-8, RVL1-4, RVL2-4, RVL5-4, RVM1-3.7, RVM2-3.7, 8, RNYBM8 5, RNYBS14-6 RVY1-3.2 Slicing wire connectors, Model(s):O K2(Pkg.cat No.84),O K3 (Pkg.cat No.85),O K4(Pkg.cat No.86)O K5(Pkg.cat No.87),O K Insulated spade type crimp connectors, Model(s):SNYD1-3.2,SNYD5-3.7,SNYD5-5,SNYDL1-3.7, SNYDL1-4,SNYDL2-3.7,SNYDL2- 6W(Pkck .cat No.88),O K8(P�ck .cat No.90),O K8W(NA). 4,SNYDL2-5,SNYDL5-4,SNYDLL1-3.7,SNYDLL2-3.7,SNYDM1-4,SNYDM2-4,SNYDS1-5,SNYDS2-5, SVL1-3.7,SVL1-5,SVL2-3.7,SVL2- 5,SVM 1-4,SVM 2-4,SVY1-3.2,SVY2-3.2,SVY5-3.7,SVY5-5,SVYL1-3.7,SVYL1-4,SVYL2-3.7,SVYL2-4,SVYL2-5,SVYL5-4,SVYLL1-3.7, Splicing w ire connectors, M odel(s): 12, 13, 14 14-6, 15, 199, 1995,200,2002,2006-5,2008-5,2011-5,22-10,22-12,29,299,2995,30 SVYLL2-3.7,SVYM 1-4,SVYM2-4,SVYS1-5,SVYS2-5,SVYS5-4 300,32,33,34,340,36,37,38,39,399,400 400AL,42, 50 615069,66,70 800,AS-1/0,AS-2,AS-2/0,AS-350,AS-4,AS-4/0,AS-500, AS-6, B1 B2, B4, BT-2, BTC 1/0-10, BTC 1/0-14, BTC 2/0-14, BTC 250-4, BTC 350-1/0, BTC 4/0-10, BTC 4/0-2, BTC 4/0-6, BTC 500-1/0, BT Insulated splice connectors, Model(s): PB1-, PB2-, PB5- 500-14, BTC 500-4, BTC1/0-10, BTC2/0-14, BTC250-4, BTC350-1/0, BTC4/0-10, BTC4/0-2, BTC4/0.6, BTC500-1/0, BTC500-14, BTC500-4LL , BV1, BV1, BV2, BV2 BV5, BVS,C=3 C=4,C=5 Kam, K1000, K2 Kam, K250, K3 Kam, K350, K4 K500, K6 K750, K8, KS10, R1,S1/0,52, LZ Insulating caps or covers,for use on manufacturer's splice caps,for 2006-5,2008 S connectors, Model(s):2007 S2L,5250,53,S3L 5350,54,5500,56,TRQ I TRR W1,WLL 2,W4,WT1,WT2,WT3,WT4,WT6 WTW51,WTW52,WTW53,WTW54 Insulating caps or covers,for use on manufacturers splice caps,for 2011-5 connector, M odel(s):2014 Splicing Wire Connectors, M odel(s): BNT1, BNT2 Splicing Wire Connectors% Model(s):46-404,46-405 Splicinig wire connectors, Model(s):H-1566, H-1567, H-1570, H-1571, H-1572, H-1591, H-1592, H-1594 Terminal connectors, Model(s): 10, 11 22,250 300,341,342,410 with insulating cap No.415,411 with insulating cap No.417,412 with insulating cap No.417,451 452,454 48,49 49 Black, 53�B 59B 600,71 B#,72B#,73B#,73B+,74B,76B 76B+,78B+,82 K-5504, LSNL2-4, M-3, PV3-750, PV3-750, PV3-750,PV4-750, PV4-750, PV4-750,RNBL2-4, RNBS14-6, RNBS38-6,RNBS38-8, RNYB22-10, RNYBS8-6, RV2-6, RVL2-5,SV5-5,WT1,WT2 WT3 WT4,WT41,WT51,WT52,WT53,WT54,WT6 Terminal Connectors, Model(s): RNB22-11 Wire Connectors, Model(s):65 653 Wire Connectors and Soldering Lugs, Model(s): L22 L23 L25 PS10, PS12, PS2,PS3,PS4 PS4S,P55 PS6 PS8 #-The equipment(71 B,72B and 73B)were also evaluated to the requirements of UL 2043 and are suitable for use in air handling spaces. *-May be followed by suffix B,J,T or X. NOTE-All models may be provided with or without prefix"V"or suffix"M P"or"V"and prefix"BP".All models may be followed by suffixes BT,UB or OF with or without a two or four digit num ber,with or without suffixes B, LP, NP,PF, PH,SP and/or T.Die Series term Vials m ay be followed by Suffixes UI,UT,UF,US,or UB,with or without a two to four digit num ber,with or without Suffix T or B, followed by Suffixes SP,LP, NP,PF,or and/or NM,by PH or BE,with or without Suffixes NT, BS,and/or G. The appearance of a com pany's nam eor product in this database does not in itself assure that products so identified have been m anufactured under UL Solutions'Follow-Up Service.O dy those products bearing the UL Mark should be considered to be Certified and covered under UL Solutions'Follow-Up Service.Always look for the Mark on the product. UL Solutions perm its the reproduction of the material contained in Product iQ subject to the following conditions:1.The Guide Inform ation, Assem blies,Constructions,Designs,System 5 and/or Certifications(files)m ust be presented in their entirety and in a non-m sleading manner, without any m anipulation of the data(or drawings).2.The statem ant"Reprinted from Product iQ with perm fission from UL Solutions"m ust appear adjacent to the extracted m aterial.In addition,the reprinted m aterial m ust include a copyright notice in the following format: "©2023 UL LLC." Y V 6 N N LL WALL CONNETOR --- The Tesla Wall Connector is an efficient and convenient home charging solution that lets you plug your vehicle in overnight and start your day fully charged. Compatible with all Tesla vehicle models,Wall Connector offers up to 77 km or 44 miles of range per hour of charge. It is approved for indoor and outdoor installation, and is compatible with any home electrical system. PERFO PM A N E SPECI FICA TO N S 10 155 mm N cminal V dtage 1-phase 230 V L-N — --__ 3-phase 230 V L-L � 3-phase 400 V L-L r Current Maximum 32 A(adjustable by installer) I T a 5 L q G rounding Scheme TN/TT/IT Frequency 50/60 H z Means of D isconnect External branch circuit breaker Residual Current Detection Integrated(Type A+D C6 mA) 345 mm Connectivity Wi-Fi(2.4 G H z802.11b/g/n) CO M FLIA N (E IN FO RM ATO N A gency A pprovals CE,IEC 61851-1 CB 1 EN VfRO N M IN TA LSPECIFICA TO N S i Operating Temperature -30°C to 50°C Storage Temperature -400C to 850C Enclosure Rating IP 55:indoor and outdoor use M ECH A NGA LSPECIFICA 110 N S Wall Connector D inensions 345 mm x 155 mm x 110 mm Wire Box Bracket D imensions 250 mm x 120 mm x 50 mm Weight(including bracket) 6.8 kg(15 lb) Cable Length 7.3 m(24 ft) 110 mm T - 5 L n 2022-03-15 TESLA.CO M/f-zN MG Y P7 structural ENGINEERS July 05, 2023 EcoFasten Solar LLC 4141 W Van Buren St,Ste 2 Phoenix,AZ 85009 TEL: (877)859-3947 Attn.: Eco Fasten Solar LLC-Engineering Departm ant Re: Report#2015-05884HG.20.01—EcoFasten-Rocklt System-Sm art Slide Attachm Ent-for Gable and Hip Roofs Subject: Engineering Certification for the State of Texas PZSE,Inc.—Structural Engineers has provided engineering and span tables for the EcoFasten-Rocklt System,as presented in PZSE Report#2015-05884HG.20.01,"Engineering Certification for the EcoFasten-Rocklt System with Rocklt Sm art Slide Assem by for Gable and Hip Roofs". All inform a:ion,data,and analysis therein are based on,and com dy with,the following building codes and typical specifications: Building Codes: 1 ASCE/SEI 7-10&7-16, M nim un Design Loads for Buildings and Other Structures, by Am aican Society of Civil Engineers 2. 2012-2021 International Building Code 3. 2012-2021 International Residential Code 4. AC428,Acceptance Criteria for M odular Fram hg System sUsed to Support Photovoltaic (PV) Panels, Novem ber 1,2012 by ICC-ES 5. Alum hum Design M anual 2010,2020, by The Alum hum Association,Inc. 6. ANSI/AW C NDS-2018, National Design Specification for Wood Construction, by the Am aican Wood Council Design Criteria: R isk Category II Seism b Design Category=A-E Exposure Category= B, C& D Basic Wind Speed (ultim le)per ASCE 7-16=90 m ph to 180 m ph For Houston,TX: Basic Wind Speed ASD M inim urn 110 m ph to 147 m ph(3-sec gust ASCE 7-10 for IRC) Basic Wind Speed ASD M inim Lin 110 m ih to 147 m ih(3-sec gust ASCE 7-10 for IRC) Ground Snow Load=0 to 60(psf) DIG TALLY SIG ICED This letter certifies that the loading criteria and design basis for the F-15844 EcoFasten-Rocklt System Span Tables are _ --oF�•��� in com Oiance with the above codes. ��P�E•. ' •rF�gs►�1, S* '•*�� f..*.:.. ................:..*.i If you have any questions on the above,do not hesitate to call. P L K.ZACHER i �..... . .....................0 Ill� 11222 .'�; Prepared by: f�I . '.�o E N s�.•���� PZSE,Inc.—Structural Engineers qk;RAC EN= Roseville,CA 1478 Stone Point Drive,Suite 190, Roseville, CA 95661 916.961.3960 r 916.961.3965 W www.p7se.com ,�penence I Iniegrily I Empoweirner.. oAa EcoFasten, - . For Installers By Installers ROCKIT COUPLING The fast installing Rocklt Coupling _r► easily attaches to the module frame to bridge the gaps between modules. SKIRT The sleek black Skirt installs first and acts as an alignment guide for the entire array. The Skirt End Cap does double duty as a skirt coupling device and an aesthetically- pleasing finishing touch. ROCKIT MOUNT Featuring integrated bonding pins, the Rocklt Mount connects to the Slide and can easily be positioned for fast installation. Features top- down leveling. CO M FLETE RAIL-LESS RACKIN G SYSTEM The Rocklt system is the industry's premier rail-less PV racking system for composition shingle,tile, and metal roofs. D Esigned in conjunction w ith the needs of Composition Shingle, � installers, Rocklt quickly&easily installs w ith a single tool. Tile,Metal" I Featuring an easy-to-position alignment slide and a top- down leveling system, Rocklt is logistically intelligent w ith no need to ship or transport long rails. Components are Rail-Less available in a black finish that complements both commercial and residential applications.Conforms to UL 2703. FEA lU RES & BEN EFITS Structural-Attach r • Patented w atertight technology Direct-Attach • Fully integrated bonding • Top-dow nleveling system ROCKIT COMP SLIDE • N crth-South adjustability Available in four variations,the Rocklt • Single tool install _ Slide allows installation on composition • Florida Product Approved for composition shingle roofs >25 YEAR WARRANTY( shingle,tile,and metal roofs. FRAME M L P E MOUNT STREAMLINED INSTALLATION W IrH Attaches and fully bonds MLPE's(Module MINIMAL ROOF PENETRATIONS Level Power Electronics)to the module frame with a single bolt clip. PRODUCTCUT SHEET For InstaLLers. By Installers. For InstaLLers. By Installers. ' COMP SLIDE AL BLK RI COMP SLIDE AL BLK PART NUMBER DESCRIPTION 2011013 RI COMP SLIDE AL BLK 1 2) LAG SCREW, 5/16-4", THREAD 3", EPDM BACKED WASHER 00.75 5/16" TH D 2" Head 0.34 3.87 Material Stainless Steel 2 Finish Mill ITEM NO. DESCRIPTION 1 ROCKIT V3 SLIDECOMP 2 LAG SCREW, 5/16-4",THREAD 3", EPDM BACKED WASHER 1) ROCKIT V3 SLIDECOMP 4.0 0 0.38 Z 0.03 1 .5 1 .75 2.0 Material Aluminum Finish Black REV.- CS' REV.- CS PRODUCT - For InstaLLers. By Installers. G F-1 FLASHING GLV BLK 8X10" PART NUMBER DESCRIPTION 3012020 GF-1 FLASHING GLV BLK 8X10" 1 ITEM NO. DESCRIPTION 1 GF1 M-GAL-BLK-810 W/O WASHER ASSEMBLY 1) GF1 M-GAL-BLK-810 W/O WASHER ASSEMBLY 8.0 10.0 00.3 THRU MMIYY 1 0.31 0.02 Material lCorrosion Resistant Steel Finish Black REV.- CS' structural ENGINEERS Septem ber 15, 2022 EcoFasten Solar LLC 4141 W Van Buren St,Ste 2 Phoenix,AZ 85009 TEL: (877)859-3947 Attn.: Eco Fasten Solar LLC- Engineering Departm Ent Re: Report#2015-05884HG.07.01—EcoFasten- Rocklt System for Gable and Hip Roofs Subject: Engineering Certification for the State of Idaho PZSE, Inc.—Structural Engineers has provided engineering and span tables for the EcoFasten-Rocklt System,as presented in PZSE Report#2015-05884HG.07.01, "Engineering Certification for the EcoFasten-Rocklt System for Gable and Hip Roofs". All inform Aion, data,and analysis therein are based on,and com Oy with,the following building codes and typical specifications: Building Codes: 1 ASCE/SEI 7-10&7-16 M him urn Design Loads for Buildings and Other Structures, by Am E•ican Society of Civil Engineers 2. 2012, 2015, &2018 International Building Code 3. 2012, 2015, &2018 International Residential Code 4. AC428,Acceptance Criteria for M odular Fram ing System sUsed to Support Photovoltaic (PV) Panels, Novem ber 1, 2012 by ICC-ES 5. Alum hum Design M anual 2010&2018, by The Alum hum Association, Inc. 6. ANSI/AW C NDS-2015&2018, National Design Specification for Wood Construction, by the Am Eican Wood Council Design Criteria: R isk Category II Seism L Design Category=A-E Exposure Category= B, C& D Basic Wind Speed (ultim ate) per ASCE 7-16=90 m ph to 180 m ph Ground Snow Load=0 to 60(psf) DIG ITALLY SIG NED This letter certifies that the loading criteria and design basis for the EcoFasten -Rocklt System Span Tables are ASS\ONAL FNG� in com Oiance with the above codes. Q�oF ��cENSEo If you have any questions on the above,do not hesitate to call. E .276-1 024 p11 O Prepared by: 104U�K.ZP, PZSE, Inc.—Structural Engineers Roseville,CA 1478 Stone Point Drive,Suite 190, Roseville, CA 95661 916.961.3960 916.961.3965 www.pzse.com