Loading...
HomeMy WebLinkAbout22-1875 1943 Fillmore St- City Approved Plans OF I OF TIN vM'IS �IN YFAUfj City of Twin Falls �0 �� General Inspection Notes �0 0 SE'RV►NG SE RVtNG �/ NOTE: This is not a complete list and is not inclusive of all construction methods, materials or practices. These checklists are intended to serve as a guide for the items that cause the most issues during inspections and promote consistency in the application of the codes & standard practices. Compliance with all the provisions of applicable codes shall be required. O The information in the checklists is not, or was it ever intended to be, all inclusive. It does not include all code or individual plan requirements. It is intended to reflect local policies, procedures & practices within the City of Twin Falls. These checklists do not waive any specific code requirements not listed or allow for the decrease in the requirements of an engineered design. It also does not add requirements where the minimum of the code has been met. Z This page and all approved plans, associated documents, revisions & changes to the plans must be maintained on site and available for review at all times. FIRE BUILDING FINAL INSPECTION INFORMATION O Fire Alarm Inspection: Footing/Foundation Inspection: COMMERCIAL OCCUPANCY • * Fire alarm plans must be approved by the State Fire Marshal's office or if applicable the Twin Falls * All re-bar must be tied in place at time of inspection. Fire Marshal prior to installation and inspection. * All hold down anchors installed properly. Final inspections are required by multiple City Departments/Inspectors prior to getting your * Fire alarm system must be wired to call out from a land line, or with a cell dialer. (Voice over IP is not Certificate of Occupancy. allowed). Shear Inspection: * Fire alarm system must be live and capable of calling the Twin Falls Dispatch Center on the day of * All hold downs must be installed per approved plans and manufacturers installation guide. Make sure to have the approved set of plans and inspection card on site for all inspections. testing. * Fasteners should not be overdriven and shiners should be removed and/or replaced. * Install the correct type of fastener at the correct spacing. If you have Special Inspections: Once the required special inspections have been completed a final Fire Sprinkler Inspection: report needs to be submitted to the building department certifying corrections of any discrepancies * Fire sprinkler plans must be approved by the State Fire Marshal's office prior to installation and Framing Inspection: noted in the special inspection reports.This final report can be submitted any time before requesting inspection. Underground fire sprinkler line must be inspected by the Twin Falls Fire Department prior * Accessibility standards are in compliance. (ICC A117.1-2009) occupancy. to be covered. * Required load paths to footing for all load points are installed. * Pipe or hose used for flushing the underground sprinkler line must be secure, incapable of * Stair rise and treads must meet code requirements. * Required Site Work inspections may be requested and completed as the work is done or as required movement, and is deemed safe by the inspector. *Min rise 4", Max rise 7", Max tread 11" by the specific department by contact the following: * Rough to cover inspection and hydro testing must be completed before covering or tenting the *Min nosing is 3/4", Max nosing is 1 1/4" and cannot differ in length by more than 3/8" above ground fire sprinkler system. * Provide required up-lift protection for all trusses. - Planning&Zoning (parking and landscaping) Planner-208-735-7270 or Office-208-735-7267 Kitchen Hood Inspections: Final Inspection: - Engineering (Retention, curb, gutter, sidewalk, drive approaches) * Fire suppression system must be installed and ready for trip test (trip link, balloons, etc.) prior to * Landings to meet minimum code requirements. (Doors 1010.1.6, Ramps 1012.6, Stairs 1011.6) Lab inspection line 208-735-3446 inspection. * Accessibility Standards are in compliance.(ICC A117.1-2009) -Street Department (road cuts) * Kitchen hood must be wired to initiate the fire alarm upon activation of the fire suppression system. * Egress door sign-age is posted and correct verbiage is used. Office- 208-736-2226 (The only exception to this is if the building does not require a fire alarm to be installed) * "DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED" * All electrical outlets, lighting, and appliances under the kitchen hood must shut down upon *Correct hardware has been installed on all doors. * When you are ready for any Fire Department inspections please call (extinguishers, activation of the fire suppression system. *Panic hardware is installed where required. fire/alarm/sprinkler systems): * Main gas valve must be installed and must shut down upon activation of the fire suppression *Accessible hardware is installed where required. Fire Marshall -208-735-7232 system. * Handrails shall be installed where required. * Exhaust fan must be capable of running continuously upon activation of the fire suppression * Stairways shall have handrails on each side. * When you are ready for a building final inspection on the structure: system. * All racking and shelving to be in place. Make sure you have the final inspections on the plumbing, electrical, and mechanical work. * Make up air must be capable of running continuously upon activation of the fire suppression system. * All Exit signs are field verified. (must be visible—nothing can block the line of sight) Call the building inspection line 208-735-7333 * Maximum Occupancy signs posted where required. All departments will be notified by this office to go do their final inspection. Final Inspection: * Special Inspection reports and balance reports need to be received by our office. * Address must be posted as outlined on the approved set of plans or previously approved by the If there is an elevator in the building please contact the Division of Building Safety at the following link Twin Falls Fire Marshal. PLANNING &ZONING for any permits/inspections: http://dbs.idaho.gov/programs/industrial/fagEL.html I ENGINEERING Landscaping: Once ALL the departments have signed the Certificate of Occupancy the Building Official will sign and * Our code allows for us to issue a TCO with landscaping incomplete; however, we cannot extend the then it will be ready to be picked-up or emailed. In order to streamline and eliminate confusion in regards to the engineering department commercial TCO beyond the current planting season.This means that we will work with the applicant on a V J permit inspections,the following will need to be inspected prior to signing the Certificate of definitive date of their choosing, but not typically beyond 2-3 months. If you need a Temporary Certificate of Occupancy there is a $1,000 refundable deposit required. All Occupancy. All inspections will be completed using the City of Twin Falls approved (stamped) plans. departments are required to sign and give a list of outstanding issues. Once the temporary is all signed Trash Enclosures: &the list made you will need to come in and sign stating you know what those issue are, that you will Storm Water Facility Inspections: (3 phases) * Trash enclosures should be finished before a final inspection is requested,this includes the front have them completed by the specified time, and will call for inspection as those items are completed. * Inspection of excavation, including dimensions and geotextile fabric. All adjoining trenches leading gate on the enclosure. Per our code, we cannot issue a TCO if this item is not completed. It is up to each department to determine if you meet their qualification for temporary occupancy. to storm water facilities also need to be excavated and inspected. * Inspection of storm drain pipes (per plans) need to be in place (not covered)for visual inspection. Note: If a building was originally done as a shell, the shell building permit is required to be finaled The drain rock must meet ISPWC section 801 Drain Rock requirements. All pipe connections to storm prior the tenant improvement permits can be finaled. In addition, if Temporary Occupancy is needed water facilities must be completed. there will be $1,000 refundable deposit for each permit. * Inspection of completed storm water facilities with the above referenced drain rock and geotextile fabric showing proper cover and overlap. • Site Inspections: * Verify that the parking lot layout (design) &striping matches the plans * Verify that the parking lot surface is an approved "hard" surface * Verify that there is ADA compliant access from the Right-of-Way(ROW)to the building envelope Right-Of-Way Inspections: * Verify driveway approach widths & locations according to plans * Verify ADA compliance of Curb/Gutter, Sidewalks, and Sidewalk/Driveway combinations CITY APPROVED PLANS * Verify ROW connections to other Agencies/Entities meet's ADA tolerances O Flood Plain Inspections: Reviewed for Code Compliance * Verify flood plain location and compare plans to the site * Verify the commercial buildings are one foot above base flood elevation PLANS MUST BE ON JOB SITE When ready for inspection please call the Engineering inspection line at (208) 735-3446 for same day inspections call before 7:30 am. Having these inspections approved when the work has been FOR ALL INSPECTIONS • completed will ensure the Certificate of Occupancy is issued in a timely manner. 2015 IBC Section 105.4 Validity of Permit: The issuance or granting of a permit shall not be a permit for, or approval of, any violation of any of the provisions of this code or of any other ordinances of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the building official from requiring the correction of errors in the construction documents and other data. The building official is authorized to prevent occupancy or use of a structure where in violation of this code or of any other ordinance of this jurisdiction. Page 1 of 36 NOTES: a.) THE GENERAL CONTRACTOR SHALL VERIFY ALL ITEMS ON THIS SCHEDULE FOR ACCURACY PRIOR TO BEGINNING b.) GENERAL CONTRACTOR TO DOWNLOAD THE LANDLORD COMMENT SET FROM DATE: 4/26/22 RESPONSIBILITY SCHEDULE CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO TENANT CONSTRUCTION PROJECT MANAGER. PROTRACK FOR COMPLETE REDLINE REMARKS. PROJECT JOB NO: 22-010 DESCRIPTION G.C. CARTERS EXISTING DESCRIPTION G.C. CARTERS EXISTING DIVISION 01000 - GENERAL SUPPLY INSTALL SUPPLY INSTALL AS-IS BY U. REMARKS DIVISION 15000 - MECHANICAL SUPPLY INSTALL SUPPLY INSTALL As-a er u REMARKS "Co-Brand" DRAWN: STAFF LANDLORD BUILDING PERMIT SUBMITTAL N/A HVAC EQUIPMENT ROOF TOP O O G.C. TO PROVIDE MAINTENANCE, SEE MECHANICAL NOTES PROJECT TYPE CHECKED: CM LANDLORD BUILDING PLAN CHECK FEES NIA ROOF WORK AND EQUIPMENT CURBS • carters I 0 K Carters V-box LANDLORD BUILDING PERMIT FEES N A HVAC DISTRIBUTION, DUCTWORK • O SEE SHEET M1.0 FOR ADDITIONAL INFORMATION. S H OS H LL Work TENANT BUILDING PERMIT SUBMITTAL O BY TENANTS PERMIT VENDOR DIFFUSERS O O SEE SHEET M1.0 FOR ADDITIONAL INFORMATION. X As-is TENANT BUILDING PLAN CHECK FEES • TENANTS PERMIT VENDOR SMOKE EVAC REGISTERS N A Cold Dark Shell G. TENANT BUILDING PERMIT FEES • G.C. SHALL PICK UP PERMIT AND PERMIT FEES EXHAUST FANS AND VENTING • • • SEE SHEET M1.0 FOR ADDITIONAL INFORMATION. DEMOLITION O O STOCKROOM UNIT HEATER N/A CANYON PARK WEST Remodel LANDLORD CLEAN-UP 1 AT TURN-OVER N/A SMOKE DETECTORS O • • SEE SHEET M1.0 FOR ADDITIONAL INFORMATION. Night Work Required TENANT G.C. FINAL CLEAN-UP #1 AT TURN-OVER O O FIRE SPRINKLER MAIN N/A 1943 FILLMORE STREET TENANT FINAL CLEAN-UP#2 AT PRE-OPENING O • BY FACILITIES MANAGEMENT DEPARTMENT SPRINKLER SYSTEM NIA TWIN FALLS, ID M01 C 0 R T L A III0 NEUTRAL PIERS AND MALL BULKHEAD N/A SPRINKLER SYSTEM MODIFICATIONS N/A M 0 R G A N OTHER PERMITS, FEES, INSURANCE O O ACCESS PANELS O O WHERE REQUIRED SPACE:1943 AREA:4,912 SO/FT TEMPORARY POWER N/A PLUMBING FIXTURES TOILET ROOM) O O n 11 A R C H I T E C T TEMPORARY BARRICADES N/A WATER AND SEWER STUB • TEMPORARY GRAPHICS • • SANITARY PIPING • PROJECT KEY PLAN U 9f 711 N. FIELDER RD. TRASH REMOVAL/DISPOSAL AND DUMPSTERS O O THROUGH TO STORE OPENING DOMESTIC WATER PIPING • ARLINGTON, TX 76012 DUMPSTER AT TURNOVER O • THROUGH TO STORE OPENING WATER HEATER O • • G.C. TO PROVIDE ALTERNATE PRICE TO REPLACE. CANYON PARK WEST PH: (817) 635-5696 FINAL INSPECTIONS AND CERTIFICATE OF OCCUPANCY LANDLORD N/A MOP SINK, MOP HANGER AND HOSE • 1943 FILLMORE STREET FINAL INSPECTIONS AND CERTIFICATE OF OCCUPANCY TENANT • • DRINKING FOUNTAIN TWIN FALLS, ID 83301 FAX: (817) 635-5699 CPM VISIT THE CONTRACTOR • • COORDINATE WITH CARTER'S PROJECT MANAGER SPACE 1943 AREA: 4,912 SQ/FT GC PROJECT MANAGEMENT VISIT THE SITE O O.C'S PROJECT MANAGER SITE VISIT-CDORD.W CARTERS CPM DIVISION 16000 - ELECTRICAL DIVISION 03000 - CONCRETE WORK ELECTRICAL SERVICE CONDUIT TO TENANT SPACE O SEE ELECTRICAL DRAWINGS LICSED CONCRETE TRECCH FOR CASHDESK POWER O O ELECTRICAL SERVICE O SEE ELECTRICAL DRAWINGS - ARCHIENTECT CONCRETE TRENCH FOR PLUMBING N/A ELECTRICAL PANELS O SEE ELECTRICAL DRAWINGS - AR-2096 DIVISION 04000 - MASONRY ELECTRICAL TRANSFORMERS N/A CMU N/A LIGHTING SIGN CONTROL PANEL O O SEE ELECTRICAL DRAWINGS : BRICK O FIRE ALARM SYSTEM N A o I' DIVISION 05000 - METALS EMERGENCY LIGHTING O O SEE LIGHT FIXTURE SCHEDULE - SHEET A21 DEMISING PARTITION FRAMING O EXIT SIGNS O O SEE LIGHT FIXTURE SCHEDULE - SHEET A21 p� CORTLAND MORGAN TOILET ROOM WALL FRAMING O O O LED LIGHT FIXTURES O O 1 ISEE LIGHT FIXTURE SCHEDULE - SHEET A21 cA v e. STATE OF IDAHO STOCKROOM WALL FRAMING O O • LED LAMPS O O SEE LIGHT FIXTURE SCHEDULE - SHEET A21 OFFICE WALL FRAMING O O O LED ACCENT LIGHT FIXTURES O O SEE LIGHT FIXTURE SCHEDULE - SHEET A21 t> FITTING ROOM FRAMING O O O LED ACCENT LIGHT LAMPS O O SEE LIGHT FIXTURE SCHEDULE - SHEET A21 R MISCELLANEOUS INTERIOR FRAMING O O THERMOSTATS • O A q PROJECT COORDINATION STOREFRONT BRAKE METAL N/A WIRING,CIRCUITING,RECEPTACLES,SWITCHES LANDLORD N/A C�,DDTecn �. DIVISION 06000 - WOOD AND PLASTICS WIRING, CIRCUITING, RECEPTACLES, SWITCHES TENANT O • SEE SHEETS E100 AND E20 • e ROUGH CARPENTRY LANDLORD WORK N/A WIRING AND CONNECTION OF CASHWRAP O O SEE ELECTRICAL DRAWING E40 ROUGH CARPENTRY TENANT WORK • • ALL LOW VOLTAGE TELEPHONE AND DATA CAT-5 WIRING O O BY TENANT VENDOR ' sas oAKIANO Roe,sunE Ras m:((86 M-5E70 DIMENSIONAL LUMBER N/A SHOPPER TRACK J-BOX &CONDUIT O O SO M NINOS6I,a aem/ FAX:(No,Tat-M STOREFRONT WOOD CLADDING N/A SHOPPER TRACK CABLE • 1 • INTERIOR WOOD TRIM • • TELEPHONE CONDUIT AND PULL STRING WIRING • BLOCKING FIRE RETARDANT LUMBER&PLYWD O O TELEPHONE SERVICE • DIVISION 07000 - THERMAL&MOISTURE PROTECTION FIBERGLASS BATT INSULATION . . • PROJECT DATA / DIRECTORY- 1... AIR INFILTRATION BARRIER • r • • TENANT CARTERS RETAIL. PROJECT COORDINATOR CARD TECH '^ W C) (n SEALANT AND CAULKING 3438 Peachtree Road, ATTN. DON KAMM W (") FIRE STOPPING O O • ANY MISSING OR REPAIRS BY G.C. Suite 1800 225 OAKLAND RD. SUITE 105 ROOFING/FLASHING O Atlanta, GA 30326 r WATER PROOF MEMBRANE 860) 7 Tel. (860)Ms. Brenda Schainske S. W( CT 0683-5670 0 +,fie � 00 DIVISION 08000 -- DOORS & WINDOWS DIRECTOR OF CONSTRUCTION TENANTS ARCHITECT COfTfLA1D MOfIGlW ARCHITECT = W ILJ^ STOREFRONT ENTRY DOORS • • • G.C. TO PAINT TO MATCH STOREFRONT PROJECT MANAGI3IIENT Ma Brenda Sdieiwke 711 N. FIELDER RD. STOREFRONT ALUMINUM FRAMING AND GLASS •STOREFRONT VESTIBULE WITH DOORS N/A SENIOR DIRECTOR STORE PLANNING ARLINGTON, TX 76012 TENANT VENDORS Q p co C'7 AND CONSTRUCTION Tel. (817) 635-5696 EXTERIOR IMAGE CONSULTING SERVICES LOCKS / BY G.C. J V INTERIOR DOORS, FRAMES, • • • SEE DOOR SCHEDULE 3438 Peachtree Road, H Tel. (817) 635-5699 LIGHTING, FLOORING, MILLWORK DOOR DW. FITTING ROOM DOOR • • SEE DOOR SCHEDULE Suite 1800 SIGNS Charlie Caplan J INTERIOR DOOR LEVER SETS O O SEE DOOR SCHEDULE Atlanta, GA 30326 TENANTS ENGINEER DON PB K CONSULTING BJdPl�I ALL PURCHASING INQUIRES INTERIOR Director of Project Management 7 � r REAR SERVICE DOOR & FRAME O SEE DOOR SCHEDULE 1301 SOLANA BLVD. GO TO THE RTL PURCHASING SIGNS Office440.951.9919 O _3 < REAR SERVICE DOOR EXIT DEVICE SYSTEM O O SEE DOOR SCHEDULE BD RE�WER David K* WESTLAKE, TX 76262 EMAIL:rtlpurchosingecartem.com Cell 440.463.7826 LOCKS AND CORES O O SEE DOOR SCHEDULE ALL BID RELATED DIRECTOR OF CONSTRUCTION Tel. (817) 410-2858 MUSIC STINGRAY o Carters Retail LOW VOLTAGE SPENCER 7 (•� CALLS TO BE DIRECTED TO SYSTEM Farhat Ullah CONTRACTOR Z DIVISION 09000 - FINISHES 3438 Peachtree Road, CEJ Z BID REVIEWER Suite 1800 fullahOstingray.eom CEILING SUSPENSION SYSTEMS O O O Atlanta, GA 30326 BUILDING DEPARTMENT City of Twin Fate aaaountmonagement0stingray.co Q rQ ACOUSTICAL TILES SALES N A Tel. (678) 791-1092 203 Main Ave East U T 00 ACOUSTICAL TILES NON-SALES • 1 9 O Twin Falls, ID 83301 GYPSUM WALL BOARD DEMISING PARTITION • 1 O O PATCH AND REPAIR TENANT COORDINATOR GREG VUJNOV TEL. 208.735.7238 CCTV ITECH SECURITY VECTOR GYPSUM WALL BOARD HC TOILET ROOM PARTITIONS • 1 O O PATCH AND REPAIR GREGOWOODINVCO.COM Natalie Himmel ALARM GYPSUM WALL BOARD STOCK ROOM PARTITION O O O PATCH AND REPAIR Tel. (657) 247-2600 National Account Executive GYPSUM WALL BOARD COLUMN ENCLOSURES O O O PATCH AND REPAIR Office: 317-70 Cell: 317-679-250447 2504 GYPSUM WALL BOARD MOP SINK AREA • • • PATCH AND REPAIR Ez GYPSUM WALL BOARD OTHER • • O SALES AND FLOORING . • CODE SUMMARY DX C NON SALES FLOORING O • A C ARCHITECTURAL Cd WALL BASE SALES O O BUILDING CODE: 2018 International Building Code USE GROUP: (M) ercontile O C1.1 TITLE SHEET ryryL� VINYL BASE STOCK O • • C7.2 DOOR SCHEDULE, DOOR HARDWARE W REDUCER STRIPS, ADHESIVE, ETC. • • MECHANICAL CODE 2018 International Mechanical Code CONSTRUCTION TYPE: TYPE VB ON-SPRINKLER I O C FLOOR PREP, INCLUDING LEVELING • • 2018 International Fire Code .3 DOOR TYPES FIRE CODES GROSS FLOOR AREAS 4 912 S.F. • C1.4 STOREFRONT ENTRY AUTO-OPENER DETAILS O � y FLOOR PROTECTION • • PLUMBING CODE: 2017 Idaho State Plumbing Code O ADA.1 ACCESSIBILITY SIGNS, NOTES DETAILS /Vl O PAINTING, FINISHING SALES AREA • O EGRESS OCCUPANT LOAD 66 PAINTING, FINISHING NON-SALES AREA O O ELECTRICAL CODE: 2017 National Electrical Code O AD•1 EX. CONDITIONS SELECTIVE DEMO. FLOOR PLAN r: REPAINT AND OR TOUCH UP PAINT • • SPRINKLER: NONE O AO.2 CEILING PLAN EX. CONDITIONS SELECTIVE DEMO. CORNER GUARDS O O ENERGY CODE: 2018 International Energy Conservation Code FIRE ALARM: NONE • A1.1 CONSTRUCTION PLAN DIVISION 10000 - SPECIALTIES ACCESSIBILITY'. 2009 ANSI A.117 Accessibility Standards FIRE EXTINGUISHERS (YES) NFPA 10 • AI.2a FLOOR FINISH PLAN STORE NUMBER STOREFRONT ILLUMINATED SIGNS • • • A1.2b FINISH SCHEDULE AND DETAILS BLADE SIGN N/A O A1.3 WALL STANDARDS INSTALLATION PLAN 1 3 69 INTERIOR SIGNS LOGO SIGNS • • CHAPTER 10 MEANS OF EGRESS MINIMUM PLUMBING FIXTURES • A1.4 FLOOR FIXTURING MILLWORK PLAN CARTERS OSHKOSH BUILDING ADDRESS NUMBERS FRONT AND REAR • • OCCUPANCY CALCULATIONS: TABLE 1004.5 • A2.1 REFLECTED CEILING PLAN "COMING SOON" SIGN • O CARTERS ROOM OCCUPANT OCCUPANT 2 EXITS 2017 IDAHO STATE PLUMBING CODE • A3.0 STOREFRONT PLAN, ELEVATION EMPLOYMENT "NOW HIRING" SIGNS • • ROOM DESCRIPTION AREA FACTOR LOAD REQUIRED CHAPTER 4, SECTION 422, MINIMUM NUMBER OF REQUIRED FIXTURES • A3.1 REAR EXTERIOR PLAN, ELEVATION ISSUE TOILET ACCESSORIES OTHER THAN NOTED BELOW • • 100 SALES AREA 3.735 S.F. 60 62 YES TABLE 422.1 (MERCANTILE OCCUPANCY) • A3.2 SALES AREA ELEVATIONS AND KEY PLAN 'A'-ISSUE:PRELIMINARY TOILET ACCESSORIES:HAND DRYER • • 101 FITTING ROOM 57 S.F. 60 1 NO 22 TOILET PAPER HOLDER,SOAP DISP • A3.3 H.C. TOILET ROOMS AREA PLAN AND ELEVATIONS DATE: 4 26• • 422.2 SEPARATE FACILITIES: SEPARATE FACILITIES SHALL / / 102 HALL 162 S.F. 100 1 NO BE PROVIDED FOR EACH SEX. • A3.4 STOCKROOM HALL ELEVATIONS 'B'-ISSUE:LL REVIEW / BID SET KOALA CHANGING STATION • • 103 TOILET ROOM 75 S.F. 100 0 NO O A3.5 OFFICE PLAN AND ELEVATIONS DATE: 5/6/22 TOILET ROOM H.C. GRAB BARS • • 104 TOILET ROOM 78 S.F. 100 0 NO 1.) WATER CLOSETS: • A3.6 FITTING ROOM PLAN AND ELEVATIONS MOP HANGER • • REQUIRED: 1 PER 100 'C'-ISSUE:PERMIT SET ACCESSIBILITY SIGNAGE • • 105 OFFICE 60 S.F. 100 0 NO • A4.1 CASHWRAP, BACKWRAP PLAN AND ELEVATION DATE: 6/14/22 EXISTING: 1 MALE FIRE EXTINGUISHERS • • 106 STOCKROOM 561 S.F. 300 2 NO O A4.2 WALL DISPLAY DETAILS 'D'-ISSUE: 107 DISPLAY WINDOW 100 S.F. 300 0 NO 1 FEMALE • A5.1 INTERIOR SECTIONS DOOR CHIME N A DATE: STOREFRONT AWNING N/A 108 DISPLAY WINDOW 100 S.F. 300 Q NO 2.) LAVATORIES: • 1 1 A5.2 INTERIOR SECTIONS AND DETAIL 'E'-ISSUE: DIVISION 11000 - EQUIPMENT SUB TOTAL: 4,912 S.F. 66 REQUIRED: 1 PER 200 O A6.1 MOBILE SHELVING PLAN AND SPECS DATE: SHOPPER TRACK • • INSTALL BY TENANT VENDOR EXISTING: 1 MALE • A6.2 MOBILE SHELVING INSTALLATION DIAGRAM 'F'-ISSUE: SECURITY SYSTEM • • G.C.TO COORDINATE WITH CHECKPOINT EGRESS WIDTH PER OCCUPANT: TABLE 1005.3.2 - .20 INCHES PER PERSON 1 FEMALE O A6.3 MOBILE SHELVING ASSEMBLY DIAGRAM DATE: POS EQUIPMENT "CASH REGISTERS" • • INSTALL BY TENANT VENDOR COMM WORKS 3.) DRINKING FOUNTAIN: O A6.4 FIXED SHELVING DETAILS COMPUTER SYSTEMS O O INSTALL BY TENANT VENDOR COMM WORKS 1.) EGRESS COMPONENTS (NON-SPRINKLER) REQUIRED: 1 PER 259 1 SHEET TITLE REFRIGERATOR MICROWAVE LOCKERS BREAK TABLE O O 0.20 INCHES PER OCCUPANT x 66 OCCUPANTS = 13.2 INCHES (REQUIRED) EXISTING: 1 SAFE • • BOLT TO FLOOR WITH EXPANSION ANCHORS M.E.P. ENGINEERING AUDIO EQUIPMENT AND SPEAKERS • • 1 IINSTALL BY TENANT VENDOR 2.) ACTUAL WIDTH PROVIDED THROUGH FRONT: 4.) SEVICE SINK O E1.0 FLOOR PLAN LIGHTING WORK TITLE SHEET THROUGH FRONT AREA (1) PAIR OF 3'-0" DOORS = 68" CLEAR REQUIRED: 1 • E2.0 FLOOR PLAN ELECTRICAL WORK DIVISION 12000 - FURNISHINGS 3.) ACTUAL WIDTH PROVIDED THROUGH HALL: EXISTING: 1 • E3.0 ELECTRICAL DETAILS CASHDESK • • THROUGH REAR (1)3'-0" DOOR = 34" CLEAR E4.0 LOW VOLTAGE DIAGRAMS AND ELEC. SPECIFICATIONS WALL PANEL SYSTEM N/A • M1.0 FLOOR PLAN MECHANICAL WORK SCALE TRIM • O TOTAL EGRESS WIDTH PROVIDED: = 102" CLEAR CITY APPROVED PLANS O M2.0 MECHANICAL DETAILS FLOOR FIXTURES O • NONE STOCKROOM 1 SURFACE MOUNT WALL STANDARDS O O 1006.3.1 MINIMUM NUMBER OF EXITS: 1-500 Occupants / 2 Exits required • P1.0 FLOOR PLAN PLUMBING WORK HARDWARE AND BRACKETS FOR STANDARDS • • 1007.1.1 TWO EXIT ACCESS DOORWAYS: Exception #2 Not located less Reviewed for Code Compliance STOCKROOM MOBILE SHELVING SYSTEM O O than one third of the overall diagonal dimension of the area being DEFERRED SUBMITALS SHEET NUMBER HARDWARE STORAGE UNIT O O served. PLANS MUST BE ON JOB SITE OFFICE COUNTERS O • 1017.2 MAXIMUM TRAVEL: 250 feet Sprinklered 1.) EXTERIOR SIGNS (SEPARATE PERMIT BY SIGN CONTRACTOR) lam/\1�1 1020.2 CORRIDOR WIDTH 44" Minimum for occupant load over 50 FOR ALL INSPECTIONS 1020.4 DEAD ENDS: 20FT Max (Non-Sprinklered) 26/22 DOOR SCHEDULE GENERAL ACCESSIBILITY AND LIFE SAFETY: DOTE. 4/ JOB N0: 22-010-010 SUPPLY DESCRIPTION FINISHED SIZE DOOR FRAME 1. EVERY EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A 7. PROVIDE EXIT SIGNS AND DIRECTIONAL EXIT SIGNS AT LOCATIONS SHOWN DRAWN: STAFF USE/TYPE LATCH FUNCTION FIRE DOOR JAMB HEAD JAMB KEY, TOOL, OR SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL ON THE FLOOR PLAN. EXIT SIGNS SHALL HAVE A MAXIMUM 6" HIGH BY 3/4" INSTALL QTY SYM WIDTH HGHT. THK. MAT. FIN. MAT. FIN. THRESH. DEVICE LOCK LABEL TYPE TYPE TYPE SIZE REMARKS BE OF AN APPROVED TYPE. STROKE BLOCK LETTERS ON A CONTRASTING BACKGROUND. CHECKED: CM EXISTING TO REMAIN, CLEAN, REPLACE WEATHER 2. EXIT DOORS (INCLUDING EXISTING DOORS) SHALL NOT BE LESS THAN 36" IN WIDTH 8. EXIT SIGNS SHALL BE INTERNALLY ILLUMINATED BY TWO ELECTRIC LAMPS OR SHALL ;XEX PAIR ANOD. ANOD. KEYED SEALS AND THRESHOLD, REPLACE LOCKS. AND NOT LESS THAN 6'-8" IN HEIGHT. PROJECTIONS INCLUDING PANIC HARDWARE, BE OF APPROVED SELF-LUMINOUS TYPE. IF TWO LAMPS ARE USED, POWER SUPPLY O STOREFRONT ENTRY 3,-0„ 7'-0" 1-3/4" ALUM ALUM. ALUM ALUM. ALUM CYLINDER ENTRY NONE A/C1.3 EX EX 4 1/2" SHALL NOT REDUCE THE OPENINGS TO LESS THAN 32" IN CLEAR WIDTH. SEE DOOR HARDWARE SCHEDULE. TO ONE OF THE LAMPS SHALL BE PROVIDED BY THE PREMISES WIRING SYSTEM. DOORS SHALL BE PAINTED TO MATCH THE EXISTING 3. HEIGHT OF THRESHOLDS AT EXIT DOORS SHALL BE 1/2" MAXIMUM. POWER SUPPLY TO THE OTHER LAMP SHALL BE FROM STORAGE BATTERIES. THE DARK BRONZE FINISH OR REPLACED WITH NEW. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE. 4. CARPET PILE HEIGHT SHALL BE 1/2" MAXIMUM. TENANT WOOD PAINT PAINT ROUGH OPENING BY G.C. CUSTOM DOOR BY TENANT 5. AISLES LEADING TO REQUIRED EXITS SHALL HAVE A MINIMUM WIDTH OF 44". 1 O FITTING ROOM 3'-0" 5'-0" 1-3/4" PANEL A WOOD NONE LEVER PRIVACY NONE C/C1.3 B/C1.3 B/C1.3 4 7/8" MILLSHOP, INSTALLED BY TENANT G.C. 6. GLASS DOORS, ADJACENT PANELS, AND ALL GLAZED OPENINGS WITHIN 24" OF 9• EMERGENCY LIGHTING SHALL PROVIDED FROM AN EMERGENCY POWER GC PT2 PT2 SYSTEM AND SHALL PROVIDE A VALUE OF ONE FOOT CANDLE AT FLOOR LEVEL. ADJACENT FLOORS SHALL BE TEMPERED GLASS. C U R T L A N U G.C. S.0 REAM 16GA PAINT PROVIDED AND INSTALLED BY G.C. LAMINATE PUSH G.C. 1 O SALES TO HALL 3'-0" 8'-0" 1-3/4„ WOOD PL1/PT2 METAL PT2 NONE LEVER PASSAGE NONE B/C1.3 A/C1.3 A/C1.3 4 7/8" SIDE OF DOOR WITH WHITE PLASTIC LAMINATE PL1 GENERAL CONTRACTORS RESPONSIBILITIES M 0 R G A N EX PAINT 1. THE CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION BETWEEN SUBCONTRACTORS 18.COORDINATE ALL ACTIVITIES WITH MALL MANAGEMENT PRIOR TO START OF CONSTRUCTION. A R C H I T E C T 1 4 HC TOILET RM 3'-0" 7'-0" 1-3/4" S.0 PAINT 16GA NONE LEVER PRIVACY NONE D/C1.3 EX EX 4 7/8" EXISTING TO REMAIN BASED ON ENTIRE SET OF DOCUMENTS. NO EXTRA COMPENSATION WILL BE GIVEN TO A INTERRUPTION OF SERVICES TO THE SHOPPING CENTER/MALL OR OTHER TENANTS SHALL EX O WOOD PT2 METAL PT2 BIDDER OR SUPPLIER WHO HAS BID FROM AN INCOMPLETE SET OF CONSTRUCTION BE HELD TO A MINIMUM. COORDINATE SUCH INTERRUPTIONS WITH THE LANDLORD. EX / / DOCUMENTS. IN CASE OF INCONSISTENCIES OR DISCREPANCIES BETWEEN DRAWINGS THE EXISTING SERVICES WHICH ARE IN ANY WAY AFFECTED BY THE PERFORMANCE OF THIS WORK 711 N. FIELDER RD. 1 5 HC TOILET RM 3'-0" 7'-0" 1-3/4" S.C. PAINT 16GA PAINT NONE LEVER PRIVACY NONE D C1.3 EX EX 4 7 8" EXISTING TO REMAIN MOST STRINGENT NOTE OR CONDITION SHALL APPLY AND THE CONTRACTOR SHALL NOTIFY SHALL BE PROTECTED AND MAINTAINED. THIS INCLUDES UTILITY SERVICES FOR THE SHOPPING AR LINGTON, TX 76012 EX / WOOD PT2 METAL PT2 THE OWNER AND THE ARCHITECT IMMEDIATELY OF SUCH DISCREPANCIES. CENTER/MALL OR OTHER TENANTS THAT ORIGINATE IN OR PASS THROUGH THE SAID SPACE PH: (817) 635-5696 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY EXISTING SITE CONDITIONS 19.G.C.TO PROVIDE AND COORDINATE INSTALLATION OF TEMPORARY BARRICADES,AND DUST G.C. S.C. REAM 16GA PAINT PROVIDED AND INSTALLED BY G.C. LAMINATE PUSH AND DIMENSIONS PRIOR TO STARTING CONSTRUCTION. CONDITIONS SHOWN ON THESE BARRIER AS REQUIRED BY THE BUILDING OWNER. FAX: (817) 635-5699 G.C. 1 © HALL TO STOCK 3'-0" 8'-0" 1-3/4" WOOD PL1/PT2 METAL PT2 NONE LEVER ENTRY NONE B/C7.3 A/C1.3 A/C1.3 4 7/8" SIDE OF DOOR WITH WHITE PLASTIC LAMINATE PL1 DOCUMENTS ARE BASED ON INFORMATION SUPPLIED BY THE LANDLORD. 3.THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING A CURRENT SET OF CONSTRUCTION 20.INSTALL TEMPORARY ENTRANCE,DOORS FRAMES HOW.WHERE REQUIRED BY BUILDING OWNER. G.C. DRAWINGS ON SITE DURING CONSTRUCTION. THE CONTRACTOR SHALL INDICATE ON THESE 1 O OFFICE 3'-0" 7'-0" 1-3/4" S•C• PAINT 16GA PAINT NONE LEVER ENTRY NONE D/C1.3 A/C1.3 A/C1.3 4 7/8" PROVIDED AND INSTALLED BY G.C. PS ALL APPROVED CHANGES TO THE WORK. THIS SET OF DRAWINGS SHALL BE TURNED 21.ALL CONSTRUCTION TO CONFORM TO ALL APPLICABLE CODES AND ALL APPLICABLE LICENSED G.C. LAN WOOD PT2 METAL PT2 OVER TO THE OWNER WHEN THE PROJECT IS COMPLETE. ORDINANCES. ARCHITECT EX 22.ALL DIMENSIONS ARE TO FINISH FACE OF WALL,UNLESS OTHERWISE NOTED. AR-2096 EX 1 ® DISPLAY WINDOW 3'-0' 7'-0" 1-3/4" S.C. PAINT A PAINT NONE LEVER PASSAGE NONE D/C1.3 EX EX 4 7/8" EXISTING TO REMAIN 4.IF ANY ERRORS,DISCREPANCIES OMISSIONS APPEAR ON THESE DRAWINGS,SPECIFICATIONS WOOD PT2 METAL PT2 OR OTHER CONTRACT DOCUMENTS, THE CONTRACTOR SHALL CONTACT THE OWNER AND THE ARCHITECT. 23.ALL WOOD CONSTRUCTION ASSOCIATED WITH THIS WORK SHALL BE FIRE RESISTANT TREATED 5. NO MATERIAL SUBSTITUTIONS WILL BE ALLOWED UNLESS SUBMITTED IN WRITING TO THE (FRT). ALL NEW FRAMING AT STOREFRONT AND ABOVE CEILING SHALL BE NON-COMBUSTIBLE. EX OWNER FOR APPROVAL IN WRITING. NOTIFICATION MUST BE SUBMITTED WITHIN 10 WORKING EX 1 O DISPLAY WINDOW 2'-0" 7'-0" 1-3/4" S•C• PAINT 16GA PAINT NONE LEVER PASSAGE NONE D/C1.3 EX EX 4 7/8" EXISTING TO REMAIN DAYS OF CONTRACT AWARD. 2a.CONTRACTOR SHALL COORDINATE CUTTING OF SLAB(IF REQUIRED)WITH MALL OPERATIONS WOOD PT2 METAL PT2 MANAGER PRIOR TO BEGINNING WORK. 6.THE CONTRACTOR IS REQUIRED TO PROVIDE A LIST OF ALL SUBCONTRACTORS TO BE USED COflTLANO MORGAN EX AND SUBMIT THIS LIST TO THE OWNER WITHIN 10 WORKING DAYS OF CONTRACT AWARD. 25.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL THEIR WORK AND THE WORK STATE OF IDAHO 1 / HOLLOW PAINT 16GA NONE ENTRY 60 MIN E/C7.3 EX EX 4 7/8" EXISTING DOOR, FRAME, ADDITIONAL TENANT REQUIRED OF THEIR SUBCONTRACTORS WITH STRUCTURE AND SHELL BUILDING ELEMENTS. CONTRACTOR EX O REAR EXIT 3'-0" 7'-0" 1-3 4' PAINT P BAIR/ HARDWARE PROVIDED AND INSTALLED BY G.C. PROVIDE A COPY OF THIS LIST TO THE STORE MANAGER. SHALL IMMEDIATELY NOTIFY THE OWNER AND ARCHITECT OF ANY SIGNIFICANT DISCREPANCIES METAL PT2 METAL OWNERS DRAWINGS AND BUILDING SHELL. 7.REFER TO TENANT/CONTRACTOR RESPONSIBILITY SCHEDULE FOR WORK RESPONSIBILITY. THIS SCHEDULE HAS PRECEDENCE OVER DRAWINGS AND SPECIFICATIONS. 26.CONTRACTOR TO PROVIDE FIRE EXTINGUISHERS AS REQUIRED. PROVIDE BLOCKING AS REQUIRED. VERIFY QUANTITY AND LOCATION WITH LOCAL OFFICIALS. COMPLIANCE NOTES FOR DOORS: 8 0 NERTHE OSUPPLI DR MATERIALSIS . THI NC UDESBLE FOR KIV RI YING PACKI GNG IN AND ING LISTSLLAGAINST SHIPMENTS OF 27 CONTRACTOR WILL RELOCATE/MODIFY EXISTING SPRINKLERS AND ADD NEW SPRINKLERS PROJECT COORDINATION ORDER FORMS AND BILLS OF LADING.IF THIS IS NOT DONE THE CONTRACTOR WILL BEAR THE AS REQUIRED.COORDINATE WITH MALL MANAGEMENT PRIOR TO STARTING THIS WORK. I�J\DDTE�1-1 COST OF ANY EXPEDITED FREIGHT CHARGES TO MEET THE CONSTRUCTION SCHEDULE. 1.)DOORS:GENERAL SHALL MEET THE REQUIREMENTS OF THE BUILDING CODE&CURRENT EDITION 6.)THRESHOLDS AT DOORWAYS. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 3 4 IN. CONTRACTOR IS RESPONSIBLE FOR FILING DAMAGE REPORTS AND MUST MAINTAIN PACKING 28.CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING OF STUDS,INSERTS AND BLOCKING. T\ / MATERIALS FOR SHIPMENT OF DAMAGED ITEMS WITH IN 48 HOURS OF RECIEVING. 225 OAKLAND ROAD,SURE 105 TEL(RMI 793-5670 OF THE LIFE SAFETY CODE. (19 MM)IN HEIGHT FOR EXTERIOR SLIDING DOORS OR 1/2 IN.(13MM)FOR OTHER TYPES OF 29.CONTRACTOR TO PROVIDE FULL FLOOR PREP AS REQUIRED TO RECEIVE NEW FINISHES. SOURI WINDSO,CT 0E074 FAX:(M 1793-5690 DOORS. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT ACCESSIBLE DOORWAYS SHALL 9. THE CONTRACTOR SHALL KEEP ALL HANDBOOKS AND PAPERWORK INCLUDING ALL PACKING SUPS 2.)REGARDLESS OF THE OCCUPANT LOAD SERVED,EXIT DOORS SHALL OPERABLE FROM THE INSIDE WITHOUT ANY BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. AND BILLS OF LADING IN A MARKED ENVELOPE. THIS ENVELOPE IS TO BE TURNED OVER TO THE STORE ALL MAJOR FLOOR PREP.MUST BROUGHT TO THE ATTENTION OF THE BUILDING MANAGER SPECIAL KNOWLEDGE OR EFFORT,MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS AND SURFACE BOLTS PRIOR TO THE COMMENCEMENT OFF SAID WORK. OR ANY OTHER TYPE OF DEVICE THAT MAY BE USED TO CLOSE OR RESTRAIN THE DOOR OTHER THAN BY OPERATION OF MANAGEMENT. 7J DOOR CLOSURES,U A DOOR HAS A CLOSER,THEN THE SWEEP PERIOD EE THE CLOSER AS REQUIRED. THE LOCKING DEVICE SHALL NOT BE USED.WHERE EXIT DOORS ARE SUED IN PAIRS AND APPROVED AUTOMATIC FLUSH 10.THE CONTRACTOR SHALL DELIVER TO THE OWNER A COPY OF THE CERTIFICATE OF SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES,THE DOOR WILL TAKE BOLTS ARE USED THE DOOR LEAF HAVING AND AUTOMATIC FLUSH BOLTS SHALL HAVE NO DOOR KNOB OR SURFACE OCCUPANCY,UNCONDITIONAL LIEN WAIVERS,WARRANTIES,GUARANTEES AND EQUIPMENT 30. POS MATERIALS AND INSTALLATION BY TENANT. L MOUNTED HARDWARE.THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRED MORE THAN ONE OPERATION. AT LEAST 3 SECONDS TO MOVE TO A POINT 3 IN.(75 MM)FROM THE LATCH,MEASURED TO THE OPERATION MANUALS.THE ORIGINAL CERTIFICATE OF OCCUPANCY TO BE FRAMED r LEADING EDGE OF THE DOOR. AND MOUNTED AT STORE MANAGER'S DESK. 31 TO 3.)DOOR HARDWARE.HANDLES,PULLS,LATCHES,LOCKS AND OTHER OPERATING DEVICES ON ACCESSIBLE DOORS SHALL 8.)DOOR OPENING FORCES. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR 11.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEAN UP OF ALL TRADES. (I.E.PHONE JACKSE PHONE PANEL BY TENANT ALL OTHER WORK REQUIRED BY G.C. W LL ECT.) T HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRED TIGHT GRASPING,TIGHT PINCHING SHALL BE AS FOLLOWS: W r^ OR TWISTING OF THE WRIST TO OPERATE LEVER-OPERATED MECHANISMS,PUSH-TYPE MECHANISMS,AND U-SHAPED 12.THESE DRAWINGS ARE NOT TO BE SCALED. 32.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL CEILING WORK WITH rA m M vJ HANDLES ARE ACCEPTABLE DESIGNS.WHEN SLIDING DOORS ARE FULLY OPEN,OPERATING HARDWARE SHALL BE (1) FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THE CEIUNG PLAN AND ELECTRICAL LIGHTING PLAN. V� LL c J EXPOSED AND USABLE FROM BOTH SIDES.HARDWARE REQUIRED FOR ACCESSIBLE DOOR PASSAGE SHALL BE MOUNTED APPROPRIATE ADMINISTRATIVE AUTHORITY. 13.THESE DRAWINGS ARE NOT TO BE ALTERED IN ANY WAY WITHOUT WRITTEN AUTHORIZATION 33.ELECTRICAL CONTRACTOR SHALL BERESPONSIBLE FOR COORDINATION OF LIGHTING WITH NO HIGHER THAN 48"(7220 MM)ABOVE FINISHES FLOOR. (2) OTHER DOORS. THE OWNER AND OWNERS ARCHITECT. CEILING PLAN AND ELECTRICAL LIGHTING HTING PLAN. � 00 4.) CLEAR WIDTH. DOOR WAYS SHALL HAVE A MINIMUM CLEAR OPENING OF 32 IN.(815 MM) (a) EXTERIOR HINGED DOORS: (RESERVED). 14. MAINTAIN EGRESS AT ALL TIMES DURING STORE OPERATION. vA WITH THE DOOR OPEN 90 DEGREES,MEASURED BETWEEN THE FACE OF THE DOOR AND THE (b) INTERIOR HINGED DOORS: 5 Ibf(22.2N). 34.ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALUNG ALL in STOP. (c) SLIDING OR FOLDING DOORS: 5 Ibf(22.2N). 15.COORDINATE CONSTRUCTION TIME AND NOISE REQUIREMENTS WITH LANDLORD. LIGHT FIXTURE SUPPORTS. ♦/ wm 5) MA SHALL EUVERING LEVEL CLEARANCES AT DOORS. FLOOR WITHIN THE REQUIRED CLEARANCES THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR AND CLEAR 16.THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING OF ALL EQUIPMENT,MERCHANDISE, 35.THE GENERAL CONTRACTOR AND FIXTURE CONTRACTOR SHALL COORDINATE WITH DISENGAGE OTHER DEVICES THAT MAY HOLD THE DOOR IN A CLOSED POSITION. CARPET,ETC. THE INSTALLATION OF ALL FIXTURE CONTRACTOR SUPPLIED ITEMS. O 17.UPON COMPLETION OF CONSTRUCTION,IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR 36.THE G.C.WILL BE RESPONSIBLE FOR THE COORDINATION, UNLOADING, STORING C V� HARDWARE SCHEDULE TO CLEAN ALL FINISH SURFACES/FIXTURES PER MANUFACTURER'S INSTRUCTIONS AND TO SECURITY, AND PLACEMENT OF ALL OWNER SUPPLIED ITEMS. L J EMPLOY THE SERVICES OF A PROFESSIONAL CLEANING COMPANY TO ASSURE THE TENANT J AN ABSOLUTELY CLEAN STORE. FINAL CLEANING I TO PERFORMED NO MORE THAN ONE DAY PRIOR TO MERCHANDISE ARRIVAL. UNTIDY STORE IS TURNED OVER,THE TENANT O J O EXISTING V.I.F. G.C. TO REPLACE IF REQUIRED TO BE IN LIKE NEW CONDITION RESERVES THE RIGHT TO EMPLOY SIMILARR CLEANING SERVICES AND TO DEDUCT THE COST . FURNISH & INSTALL BY G.C. ^` PLUS 10%FROM THE BALANCE OF THE CONTRACTORS CONTRACT SUM. LL W 0 FURNISH BY TENANT & INSTALL BY G.C. a c o x o o N z z Z Z (� ^ 4 0 o w 3.L W = a a N N 2 O p p Q U O O O O O © O ® O 1 O EXISTING (VERIFY REPLACE, OR PROVIDE IF REQUIRED) O O O O O 1 O OFF SET PIVOT HINGES O AS PROVIDED BY ENTRY DOOR MANUFACTURER O 1 Ye PR. 4,T' X 4YA" STANDARD WEIGHT, FULL-MORTISE, 5 KNUCKLE, BALL- BEARING HINGES = WITH US26D FINISH, BOMMER #BB5000-450-652, OR EQUAL O 0 O O • . O O O NON REMOVABLE PINS AT EXTERIOR DOORS O L (1) FULL MORTISE, THREE KNUCKLE SPRING HINGE MOUNT IN CENTER (FINISH US26D) 0 C0 EXISTING (VERIFY REPLACE, OR PROVIDE IF REQUIRED O '�' =I PUSH/PULL PROVIDED BY ENTRY DOOR MANUFACTURER O O O x LOCKS • • /\ O W BATTERY-ALARMED PANIC DEVICE, DETE% VALUE SERIES V40%EB . V 'm MORTISE CYLINDER W LAZY L CAM • W LATCH PROTECTOR, IVES LG7, OR EQUAL • F WIDE-ANGLE PEEPHOLE, IVES 698, B26D FINISH, OR EQUAL = THRESHOLD AND WEATHER-STRIPPING REPLACE AT EXISTING DOORS . • STORE NUMBER W DOOR PULL, IVES #410, B26D FINISH, OR SIMILAR AUTOMATIC DOOR OPENERS "RECORD 8100 SERIES AUTO OPENER 1369 STORE ID, SPACE, BUILDING ADDRESS NUMBERS • EXISTING VERIFY REPLACE, OR PROVIDE IF REQUIRED ALL TO BE MEDIUM-DUTY, COMMERCIAL LOCKS WITH LEVER HANDLES: 0 . O . . . LEVER SET: PASSAGE LATCH (BOTH LEVERS ALWAYS UNLOCKED), SCHLAGE #S10D, ISSUE cx,X NEPTUNE DESIGN, 626 FINISH, OR CORBIN RUSSWIN CL3510-626 FINISH 'A'-ISSUE:PRELIMINARY S ENTRANCE LOCK (TURN-BUTTON INSIDE, KEY OUTSIDE), SCHLAGE #S51PD, DATE: 4/26/22 NEPTUNE DESIGN, 626 FINISH, OR CORBIN RUSSWIN CL3551-626 FINISH 0 0 'B'-ISSUE:LL REVIEW/ BID SET x FINAL LOCKS AND KEYS DATE: 5/6/22 p LEVER SET: PRIVACY LOCK (PUSH-BUTTON LOCK), SCHLAGE #S40D, 'Cl-ISSUE:PERMIT SET NEPTUNE DESIGN, 626 FINISH, OR CORBIN RUSSWIN CL3520-626 FINISH O 0 DATE: 6/14/22 STANDARD 4" ALUM. DOOR PULLS PROVIDED BY G.C. O O 'D'-ISSUE: PULL AND PUSH PLATE DATE: EXISTING VERIFY REPLACE, OR PROVIDE IF REQUIRED O 'E'-ISSUE: MOUNT CLOSER ON INSIDE OF DOOR O . O O • . DATE: W AS PROVIDED BY ENTRY DOOR MANUFACTURER 'F'-ISSUE: BARRIER-FREE, SURFACE-MOUNTED DOOR CLOSER, NORTON DATE: #1601BF-689, ALUMINUM FINISH, • O O • • BARRIER-FREE, SURFACE-MOUNTED DOOR CLOSER, WITH HOLD OPEN FUNCTION NORTON SHEET TITLE #1601BFH-689, ALUMINUM FINISH, w EXISTING (VERIFY REPLACE, OR PROVIDE IF REQUIRED) 201� MOUNT ON PUSH SIDE OF DOORS ONLY • O O • • DOOR SCHEDULE 218"H. X 34"W. STAINLESS STEEL KICKPLATE, IVES 8400 U532D-8X34, OR EQUAL • O O • . CITY APPROVED PLANS 30"H. X 34"W. STAINLESS STEEL KICKPLATE • DOOR HARDWARE EXISTING (VERIFY REPLACE, OR PROVIDE IF REQUIRED) FLOOR DOME STOP (FIELD VERIFY CONDITION), IVES #FS436 (WITHOUT THRESHOLD) Reviewed for Code Compliance SCALE OR IVES #FS438 (WITH THRESHOLD OR UNDERCUT), FINISH US26D, OR EQUAL NONE p0 WALL STOP WITH CONCAVE BUMPER, IVES #WS407CCV, US26D FINISH, OR EQUAL • • O O • • PLANS MUST BE ON JOB SITE i;� DOOR SILENCERS (INSTALL 3 PER DOOR), IVES #SR64, GRAY, OR EQUAL 0 • O O • • HINGE PIN DOOR STOP: - SURE LOC (SATIN CHROME) a I FOR ALL INSPECTIONS SHEET NUMBER Door-Hdr-Sch.-Mc II-REV-00 C1.2 Pagi DATE: 4/26/22 JOB NO: 22-010 DOOR TYPES DRAWN: STAFF CHECKED: CM C M T.O. STOREFRO C 0 R T L A N D 9'-11" A.F.F. M O R G A N A ARCHITECT i xx \ TRANSOM ^ XX XX CLOSER ARLINGTONIETXER76012 B.O.TRANSOM METAL FRAME PH: (817) 635-5696 7-0" A.F.F. PT2 \ WOOD FRAME METAL FRAME \ FAX: (817) 635-5699 �A AUTOMATIC DOOR SOLID CORE SOLID CORE METAL- DOOR \ WOOD DOOR gip FRAME \\\�_ CAUTION SIGN SEE SCHED. SOLD WOOD WOOD DOOR AS REQ IRED ON ACTVE OR FOR FINISH. / DOOR WITH / 3.OR FNSE HSH. VIEWER ED. PEEP OLE A_R1 ECT PL1 FLUSH PANEL 24 CIN AUTOMATIC DOOR OPENER JAMB MOUNT 2 " \ SPRING / LEVER SET. TENANT PANIC AR-2096 PUSH PLATE \ PUSH / PULLS ' o HINGE SEE HARDWARE HARDWARE MS SEDCO /59J-HSS SCHED. `o PT2 ENTRY DOORS AND HDW 1 I PT2 I \ PER DOOR SCHEDULE ^ / BRUSHED B ^ INSUL. ^ \ PAINT TO MATCH STOREFRON A / STAINLESS XX \ 2" A BRUSHED STAINLESS HOLLOW CORTLAND MORGAN FRAMING OR REPLACE. XX LEVER SET. HINGE PIN XX LEVER SET.SEE MTL. DOOR STATE OF IDAHO ORDINATE WITH P.M. SEE HARDWARE DOOR HARDWARE SCHED., SCHED. STOP > 30 X 34 8 X 34 BRUSHED BRUSHED STAINLESS STEEL STAINLESS / PROJECT COORDINATION • KICK �j OPEN 8 X 34 BRUSHED STEEL KICK STAINLESS STEEL KICK CADDTeBficr-i TYPE A TYPE B TYPE D TYPE E SONN WINDSOR�CT'WjE 105 TM-%W1� PAIR 3'-0" X 7'-0" 3'-0" X 8'-0" 3'-0" X 5'-0" 3'-0" X 7'-0" 3'-0" X 7'-0" ALUMINUM / TEMPERED GLASS 1 3/4" SOLID CORE WOOD 1 3/4" WOOD PANEL DOOR 1 3/4" SOLID CORE WOOD 1 3/4" HOLLOW METAL ENTRY DOORS FLUSH DOOR FLUSH DOOR INSULATED FLUSH DOOR w T LL wo JAMB AND HEAD TYPES w CO 00 W C J J r 0 ILLLaL N Z U cd U � Cn 4� TRIM 4 7/8" T-3 NI PT2 �..� O 3 5/8" OR 6" STEEL E(2y)P20 GA. MTL. STUDS ML own STUD WALL W/ . O JAMBS) W (2) 20 GA. MTL. TYPE 'X" GYP. GYP. I ` XI STUDS TYP. O BD. EACH SIDE X 4 FRT WOOD BUCK O y HEAD) � (TYP. O JAMBS) 16 GA. METAL I 1/2" X 2" DOOR STOP O FRAME, STOP, & CASING. I (TYP. O JAMBS) DOOR DOOR LEAF STORE NUMBER HEAD ANCHOR 2" 14 1369 ISSUE HEAD TYPE'A' HEAD TYPE'B' 'A*-ISSUE:PRELIMINARY DATE: 4/26/22 *BD " " EL STUD DATE: 5/6/22 TYPE "X" GYP. TRIM (2) 20 GA. MTL. STUDS 'B'-ISSUE:LL REVIEW BID SET (TYP. O JAMBS) 'C'-ISSUE:PERMIT SET T-3 2 X 4 FRT WOOD BUCK DATE: 6/14/22 'D'-ISSUE: 2 1/ Y4"(TYP. O JAMBS) DATE: 1/2" X 2" DOOR STOP 'E'-ISSUE: (TYP. O JAMBS) DATE: R 'F'-ISSUE: B ANCHOR DATE: A. METALE, STOP, SHEET TITLE NG. ^ DOOR TYPES 20 GA. MTL. STUDS DOOR LEAF (TYP. O JAMBS) CITY APPROVED PLANS SCALE Reviewed for Code Compliance AS NOTED B' PLANS MUST BE ON JOB SITE JAMB TYPE'A' JAMB TYPE' SHEET NUMBER FOR ALL INSPECTIONS C1.3 Pa DATE: 4/26/22 NOTE: JOB NO: 22-010 MS Sedco 59J Series G.C. TO CONTACT CARTERS PURCHASING DEPARTMENT FOR DRAWN: STAFF Jamb Style NATIONAL ACCOUNT PRICING AND ORDERING INFORMATION OF THE SEoco Push Plate Switches AUTOMATIC DOOR OPENERS. CHECKED: CM S1'soas vsWl,rs� Product Name LEAD TIME FOR ORDERING IS 2 WEEKS, G.C. TO PLAN Sedco 59J Series •Rubber"Bellows"Increases ACCORDINGLY WITH PROJECT SCHEDULE. T.O. STOREFRONT \� Ull V UO Jamb Style Push Plate Switch es Weather Protection(included) 9-11 A.F.F. PUSH •Fits 13/4"Frame or MS SEDCO TO Manufacturer Surface Mount Box OPEN MS SEDCO •Special Finishes:US3,US4, 8701 Castle Park Drive US10,US10B,US32 H Indianapolis,IN 46256 •Radio Control Versions C 0 R T L A N D Phone:(800)842-2545 Available M 0 R G A N www.mssedco.com I^ B.O. TRANSOM #591JH(Bwe (Stainless Cleu"'A" Il^ AUTOMATIC DOOR 7'-0" A.F.F. A R C H I T E C T Powder Coat with Steel with B"" Product Description )).- WhitePaintFined Paint Feed p CAUTION SIGN Legend) Legend) BASIC USE G1..Pahl-Rodin C.oM-Ol ON ACTIVE DOOR / � 711 N. FIELDER RD. The 59J Series jamb style Sndrehes sahryr,b&ws wased by AS REQUIRED ARLINGTON, TX 76012 switches are designed to provide in[e,ferenceoodenapsignaLc— reliable,unobtrusive activation of ondaregnamnteedo—M,vhere. O\ PH: (817) 635-5696 others—'a AUTOMATIC DOOR PUSH PULLS FAX: (817) 635-5699 any automatic door. OPENER JAMB MOUNT TO MATCH 4 1/2" PUSH PLATE BUILDING The 59J Series features 1 1/2"x DIMENSIONS MS SEDCO #59J-HSS STANDARD - 4 1/4" face plates in either See Reverse RECORD AUTO t EXISTING LICENSED stainless steel or blue powder DOOR OPENER 1" INSULATED ARCHITECT coated aluminum with etched and APPLICABLE STANDARDS GLAZING AR-2098 paint filled legends. A formed American National Standards ENTRY DOORS #59J-HSS #59tw(Blue stainless steel back plate Institute (ANSI) - Building GLAZING STOPS AND HARDWARE (Stainless Steel Powder Coat with eliminates possible wall damage Hardware Manufacturers TO MATCH BASE BUILDING STANDARD with Blue Paint White Paint with from standard use. Association(BHMA)-ANSI/BHMA !�` Filled Legend) Legend) A156.10&A156.19. EXISTING CORTLAND MORGAN Mount the 59J Series directly onto iv SINGLE ACTING a 1 GTATF Or IOAHO 3/b of an automatic door(fits APPROVALS DOOR TRANSOM • a 3/4"frame)or in MS SEDCO's UL(Micro-Switch) optional surface mount box. Installation EXISTING Each unit is built utilizing heavy The 59J Series Jamb Style Switch DOOR HEAD INTERIOR ELEV. PROJECT COORDINATION ® gauge stainless steel, aircraft is easy to install. CADDTtNai quality rivets and screws,durable SCALE:1/2'4-0' finishes and the most reliable Hardwired Applications: EXISTING p� #591WSS(Stainless steel with Bee micreswitch in the industry. Using the mounting template 1" INSULATED 225 OAKLAND ROAD,SUITE 105 TEL 861 W-`5670 Paint Fin SOUM aND50R,ClOW71 FAX: Filled Legend) provided,make cutout in the door GLAZING NO Technical Data frame. Remove the face plate NOT SHOWN •11/2"x 41/4"All Active Face from the switch assembly. #59lPlain(Stainless Steel with No Plate Connect the necessary signal Legend) •111/16"x 41/2"Formed wires to the appropriate switch Stainless Steel Back Plate contacts (COM & N.O. are •UL Listed"Cherry Switch',SPOT, standard). Secure the switch STOREFRONT DETAIL W T Mom.,15 Amp M 125V AC assembly to the door frame and reattach the face plate. v SCALE 3'-T-O' T.O. STOREFRONT 1r 8701 Cesde Puk Ddve■Indlenap,h;Cndiwa 46256■Tit phone(800)842-2545/(317)M22545■F.(800)849-M87/(317)849-338'1 g 9-1 1" A.F.F. � �A c mss 0)f www �co.com AR cvsenc@_o,d_o ,n 1" INSULATED RECORD AUTO ca GLAZING DOOR OPENER W in AT INTERIOR MS SEDCO PUSH PLATE TRANSOM Q 50 Uj 8 SCALENONE 2"x4 1/2" ALUM. B.O. TRANSOM J DOOR JAMB 7'-0" A.F.F. Z 1 _J AUTOMATIC DOOR J_ A� ®roeoM-usa AUTOMATIC SWING DOOR OPERATORS W W wt.mnRrnFsraR.JOBNANE: BOTTOM CAUTION SIGN � LL —dre.xr rrOn sDRIEs:etoo Low lox EIEROT oruuroR DOOR RAIL ON ACTIVE DOOR Z LOCATION: CA AS REQUIRED Z CO Cd rIBMr'd iTca.ce-eats N E, OU (N etoa(wit) rmF: ouTSMANo ARN PACF et-z.oz �-F SQUARE BACK `o \UTOMATIC DOOR Q VCL _ a.ocNlxc/smucneui ALUMINUM )PENER JAMB MOUNT PUSH / PULLS '` C/� suPPORr THRESHOLD SET IN 1USH PLATE / n U CA oTHLRs FULL MASTIC AS SEDCO #59J-HSS c ----------- ------- ENTRY DOORS -� EXTERIOR AND HARDWARE —5"[1271 FCS MAT CONCRETE WALK PER DOOR \ SCHEDULE SAI � M \\\\ x = � STOREFRONT DETAILCd `� SCALE 3'-11-V I L. =I ELEVATION I'D" t 2 STOREFRONT EXTERIOR ELEV. U SCALE: 1/4" V O = 1'0" Re.n: (sEE NorE t) SCALE:1/2'-T-O' NTFR DR STORE NUMBER EXISTIN��culoE RNts 0 FACADE STOREFRONT i r t I (SEE NI J) 1369 T.O. ENTRY / \ - W-11" A.F.F. N]L1SNaa ISSUE etc. .1w wit alit 'A'-ISSUE:PRELIMINARY CEXISTING ALUM. DATE: 4/26/22 _ PLAN VIEW SURFACE MOUNTED AUTOMATIC HEAD PROFILE I 'B' N -ISSUE:LL REVIEW/ BID SET SCALE: 1/4" = 1'D" SERIES.DOOR OPENERS. RECORD 8100 AUTOMATIC DOOR DATE: 5/6/22 OPENER JAMB MOUNT 'C'-ISSUE:PERMIT SET �uNn NtD1x B.O. TRANSOM PUSH PLATE DATE: 6/14/22 7'-0" A.F.F. MS SEDCO #59J-HSS —TRANSOM MULLION 'D'-ISSUE: _ __ __ s1/z•[ta7 _ 2 X 4}" TRANSOM HEADER PROFILE DATE: FLOOR nNE PROFILE, FINISH TO MATCH 6 SECTION: 2 EXISTING STOREFRONT V.I.F. ---------------- ----- ——— — 'E'-ISSUE: ------- DATE: —I—— — —— 'F'-ISSUE: SCALE: 1/4 SIZE — — — — — t t/z•[x] ALUMINUM DATE: [TMP) AND GLASS AUTOMATIC DOOR / 4 ENTRY DOORS OPENER JAMB MOUNT / \ STOREFRONT PUSH PLATE / \ ENTRY DOORS SHEET TITLE o MS SEDC0 k59J-HSS _ _ -T 4DOOR DPENIND All 2 STOREFRONT ENTRY NDTES: 1.2DWENOFREVFxuProWM CITY APPROVED PLANS PHR 511oNT1 2.DIAFNSNNRS IN INCHES[MIWNEIEAS]. cLHROPPDSRD -------------------------------- VESTIBULE DETAILS 3.SElEC110N OF OPEMTDR FROM e100 rl.ENERGY)TO 8000(HQI EGUW _ SECTION: 1 V�� uN�E N�SEED%is Reviewed for Code Compliance SCALE SCALE: 1/8 SIZE RESPONSBU OF THE INSrOL EP / — PLANS MUST BE ON JOB SITE AS NOTED RI FOR ALL INSPECTIONS SHEET NUMBER n RECORD AUTOMATIC DOOR OPENER STOREFRONT ENTRY SECTION STOREFRONT PLAN C1.4 7 SCALE�NONE `F SCALE 1/2'-11-V SCALE:1/2'4-17 Pagi BLUE BACKGROUND TYP BLUE BACKGROUND TYP DATE: 4/26/22 WHITE SYMBOL TYP ICC / ANSI A117.1-2009 WHITE SYMBOL TYP JOB NO: 22-010 703.3 RAISED CHARACTERS 60" MAX. DRAWN: STAFF oox�N 60" MAX. TO 703.3.2 Depth. Tactile characters shall be raised inch minimum above their background. 48" MIN. :xe:•* CHECKED: CM 48" MIN. 703.3.3 Case. Characters shall be upper case. 5 5" °0z \- 703.3.4 Style. Characters shall be sans serif. Characters shall not be italic, oblique, script, highly GRADE 2 BRAILE TEXT (TEXT M� decorative, or of unusual forms. TO READ AS SHOWN) GRADE 2 BRAILE TEXT (TEXT CITY APPROVED PLANS PER CBC 11B-703.3 TO READ AS SHOWN) 703.3.5 Character Height. The uppercase letter "I" shall be used To determine The allowable height PER CBC 11B-703.3 of all characters of a font. The height of The uppercase letter "I" of The font, measured TACTILE EXIT SIGN PLAQUES ^ TACTILE EXIT SIGN PLAQUES Reviewed for Code Compliance vertically from the baseline of the character, shall be J inch minimum, and 2 inches maximum. 4F TA TIL 4C 703.3.6 Character Width. The upper case letter "0" shall be used to determing the allowable width of 11/2' T-17 PLANS MUST BE ON JOB SITE C 0 R T L A N 0 all characters of a font. The Width of uppercase letter "0" of the font shall be 55 percent BLUE BACKGROUND TYP M 0 R 0 A N P WHITE SYMBOL TYP BLUE BACKGROUND TYP minimum and 110 percent maximum of the height of the uppercase "I" of the font. WHITE SYMBOL TYP FOR ALL INSPECTIONS A R C H I T E C T 703.3.7 Stroke Width. Tactile character stroke width shall comply with Section 703.3.7. The uppercase 60" MAX. ENT letter "1" of the font shall be used to determine the allowable stroke width of all characters luw 60 MAX. EXrr. 711 N. FIELDER RD. of a font. 48" MIN. ,DONI> ROUTE ARLINGTON, TX 76012 48" MIN. :xe:.. PH: (817) 635-5696 703.3.7.1 Maximum. The stroke width shall be 15 pecent maximum of the height of the uppercase "'I" FAX: (817) 635-5699 measured at the top surface of the character, and 30 percent maximum of the height of the M� 5" \z uppercase letter "I" measured of the base of the character. GRADE 2 BRAILE TEXT (TEXT r.X� 703.3.7.2 Minimum. When characters are both visual and tactile, the stroke width shall be 10 percent TO READ AS SHOWN) GRADE 2 BRAILE TEXT (TEXT 3 TO READ AS SHOWN) minimum of The height of the uppercase letter "I PER CBC 11B-703. LICENSED PER CBC 11B-703.3 AHO ARCHITECT 703.3.8 Character Spacing. Character spacing shall be measured between the two closest points AR-2096 in adjacent tactile characters shall bin a message, excluding word spaces. Spacing between TACTILE EXIT SIGN PLAQUES TACTILE EXIT SIGN PLAQUES individual tactile character shall be b inch minimum measured at the Top surface of the A C / 41� 11/2'-1,-°• characters, Inch minimum measured at the base of the characters, and four times the �}C 11/2'-T-0' v tactile character stroke width maximum. Characters shall be separated from raised boarders and decorative elements J" inch minimum. BLUE BACKGROUND TYP BLUE BACKGROUND TYP BLUE BACKGROUND TYP CORATE OMDRGAN 703.3.9 Line Spacing. Spacing between The baselines of separating lines of tactile characters within WHITE SYMBOL TYP STATE D ORG a message shall be 135 percent minimum and 170 percent maximum of the tactile character WHITE SYMBOL TYP E WHITE TEXT height. 60" MAX. 703.4 Braille. 48" MIN. RAMP _ .0" MAX. �e 60" MAX. I in 6 BLUE BACKGROUND TYP 48" MIN. :x.;. �,x,. WHITE SYMBOL TYP PROJECT COORDINATION 703.4.1 General . Braille shall be contracted (Grade 2) braille and shall comply with Section 703.4 5„ ns 5" �z - MIN. CADDTECf-1 703.4.2 Uppercase Letters. The indication of an uppercase letter or letters shall only be used before GRADE 2 BRAILE TEXT (TEXT GRADE 2 BRAILE TEXT TEXT GRADE 2 BRAILE TEXT TEXT 60 MAX. The first word of sentances, proper nouns and names, individual letters of the alphabet, ( ( tT5 DucuND ROAD,SUITE 1B5 TEL((M T83-567D initials, or acronyms. TO READ AS SHOWN) TO READ AS SHOWN) TO READ AS SHOWN) SDUIR WINDSOR.CT DemA FAX.( )793-5680 PER CBC 11B-703.3 PER CBC 11B-703.3 703.4.3 Dimensions. Braille dots shall have a domed or rounded shape and shall comply with Table 703.4.3 TACTILE EXIT SIGN PLAQUES TACTILE EXIT SIGN PLAQUES SIGN OF ACCESSIBILITY DECAL 703.4.4 Position. Braille shall be below the corresponding text. If the text Is multi lined, braille shall be 4D 11/2'-Y-0' 4A 11/2'-T-V 3 11/2'-T-°' placed below the entire text. Braille shall be separated J inch minimum from any other tactile W ILL characters and I inch minimum from raised boarders and decorative elements. Braille provided O '^ on elevator car controls shall be separated A inch minimum either directly below or adjacent Ir Ir vJ To The corresponding raised characters or symbols. w co CAI in 703.4.5 Mounting Height. Braille shall be 48" minimum and 60" maximium above the floor, measured to co 0 the baseline of the braille cells. V/ 7 ICC I ANSI 117.1 — 2009None Q O Jr O� U_ ILL N SIGN:#3 Z U T.O.STOREFRONT O ISA PLAQUE AT ® O ZCd FITTING ROOM (� 1 O — — — /----- V co u, 6' BLUE 6" BLUE 6. BLUE B.O.0 A.F TRANSOMi. I ❑ 7- y*gg gg III I II F =I ■l? V TYPICAL TACTILE SIGN ��� / \ I❑ om ]EITE AUTOMATIC Dooft O\ SEE DETAIL #4A I O RADE 2 BRAILE TE%T(TEXT WNITE WHITE OPENER JAMB MOUNT I w[ PUSH PLATE \ I W TO READ AS SHOWN ON SIGN MS SEDCO/69J-HSS — I FOR EACH CONDITITON,TYP.) N: DOOR TO REMAIN 0 =I \ �j a BUI DINGUNLOCKEDI WHEN TOILET ROOM PLAQUES ` ® °G°°PIE° V O 6 1/4•-,'-° SIGN: SIGN OF -9I 26 ACCESSIBILITY, SE Ip-- E m F N='�H ELEVATION DETAILS #3 ❑ OI 2A STORE NUMBER no TACTILE EXIT SIGN LOCATION o : E%IT# �0 3/8'- III 1369 I A _Er�jy D O ISSUE T.O.STOREFRONT c 'A'-ISSUE:PRELIMINARY 9-11 A.F.F. 4 22 I III / / 'B'-ISSUE:ILL REVIEW BID SET _ ®® / 7 DATE: 5/6/22 N ..... a DATE: 26❑ O O III ACCESSIBLE COMPLIANT I `„ _ _ -ISSUE:PERMIT SET TOILET ROOM SIGN PER B.O.TRANSOM I I DATE: 6/14/22 GENDER OR UNISEX AS 7'-0'A.F.F. SIGN:#4B APPLICABLE PER ABOVE. EXIT ROUTE II - ti II ,D, DATE! / \ 6" x 6" SIGN OF _ I I I ACCESSIBILITY D IIHH 'E'-ISSUE: ACCESSIBLE COMPLIANT /O DECAL, SEE - / - - DATE: AUTOMATIC DOOR DETAIL #3 TOILET ROOM SIGN PER / 'F'-ISSUE: OPENER JAMB MOUNT GENDER OR UNISEX AS PUSH PLATE f 1J DATE: 9" APPLICABLE PER ABOVE. Ms se0co#59J-HSS ��" SHEET TITLE -0 >< ------ .I \ / GENDER ;]ISA AND ACCESSIBILITY o Q I e LATCH SIDE ..❑ W N PLAQUE#511 I a SIGNS, NOTES L-___J III DETAILS i SCALE AS NOTED LEAR FL . SPACE _----_ ENTRANCE SIGN OF ACCESSIBILITY L------J SHEET NUMBER 2A3/8'-T-0' SIGN:#4A SIGN MOUNTING AT TOILET ROOM I INTERIOR DOORS EXIT 5 ,/2•-T- ACCESSIBLE SIGN KEY PLAN ADA.1 Pa 59'-01" DATE: 4/26/22 LEASE DIMENSION O GENERAL DEMOLMON NOTES: JOB NO: 22-010 O 3 2 1 1 I.THE SECTION IS INCLUDED FOR GENERAL CONTRACTOR REFERENCE WORK TO BE PERFORMED BY GENERAL CONTRACTOR DRAWN: STAFF r I (G.C.) APPLIED AS NEEDED TO STORE. CHECKED: CM 2.G.C. IS TO REMOVE ALL EXISTING LEASEHOLD IMPROVEMENTS AS REQUIRED TO ACHIEVE SCOPE OF WORK NOTES. O - - - - - - - - - - - - - DEMOLITION INCLUDES, BUT IS NOT LIMITED TO THE REMOVAL OF ALL EXISTING INTERIOR WALLS, PARTITIONS, CEILINGS, FLOOR COVERINGS, PLATFORMS, DISPLAY SHOW WINDOWS, CABINETS, ETC. UNLESS NOTED OTHERWISE. DEMOLITION ALSO INCLUDES THE REMOVAL OF ALL EXISTING ELECTRICAL, MECHANICAL AND PLUMBING FIXTURES AND EQUIPMENT L-----------------J UNLESS NOTED ON MECHANICAL AND ELECTRICAL DRAWINGS. F - 3.ALL ABANDONED ELECTRICAL/TELEPHONE CONDUIT, PLUMBING LINES, DRAIN LINES, AND MECHANICAL DUCTWORK AS THE RESULT OF DEMOLITION SHALL BE REMOVED. \� 6 1NG RM'S I� I � 4.G.C. IS TO COORDINATE THE DISCONNECTION AND CAPPING OF ANY UTILITIES WITH LANDLORD'S FIELD REPRESENTATIVE. I I I �H� FTf1 I I I I R T D 5.IN ORDER TO CAUSE THE LEAST AMOUNT OF INCONVENIENCE, G.C. IS TO COORDINATE WITH ALL ADJACENT SPACES A C O L A N 6._8- CONVENIENT TIME TO PERFORM DEMOLITION WORK. G.C. IS TO PROVIDE AND INSTALL ALL TEMPORARY PROTECTED MEANS MI 0 R G A N OF EGRESS. TEMPORARY LIGHTING, AND ALL SAFETY DEVICES IN ACCORDANCE WITH ALL STATE AND LOCAL CODES AND I I I I I LANDLORD REQUIREMENTS. ARCHITECT 21 I 6.G.C. IS RESPONSIBLE FOR PATCHING AND/OR REPAIRING EXISTING FLOOR SLAB, DEMISING WALLS, AND ROOF DECK 1 AFTER COMPLETION OF ALL DEMOLITION AND PRIOR TO THE COMMENCEMENT OF NEW CONSTRUCTION. G.C. IS TO 711 N. FIELDER RD. DISPLAY WINDOW HTTING RM'S W2 COORDINATE WITH LANDLORD RESPONSIBILITY IN PERFORMING ANY AND ALL ROOF WORK. G.C. IS TO PATCH, REPAIR ARLINGTON, TX 76012 AND LEVEL EXISTING FLOOR SLAB AND INFORM TENANT OF ALL SEVERE IRREGULARITIES IN EXISTING SLAB IMMEDIATELY. PH: (817) 635-5696 7.G.C. IS TO EXERCISE EXTREME CARE DURING DEMOLITION SO AS NOT TO DAMAGE OR DISRUPT ANY UTILITIES OR FAX: (817) 635-5699 6 SPRINKLER LINES WHICH MIGHT PASS THROUGH THIS SPACE TO SERVICE OTHER MALL SPACES OR OTHER TENANTS. L.L. WILL BEAR SOLE RESPONSIBILITY OF ANY SUCH DISRUPTION OR DAMAGE. - - I I I 8.G.C. IS TO ERECT CONSTRUCTION BARRICADES AND DEBRIS DUCT SCREENS PER LANDLORD'S SPECIFICATIONS. LICENSED TYP / 5 ( ) I CONTACT LANDLORD'S FIELD REPRESENTATIVE PRIOR TO THE COMMENCEMENT OF ALL DEMOLITION WORK. , ARCHITECT 2 3 1 1 AR-2098 9.WHERE APPLICABLE, G.C. IS TO COORDINATE THE REMOVAL, DISPOSAL, AND/OR RETURN OF ALL EXISTING SECURITY SYSTEMS WITH LANDLORD'S CONSTRUCTION MANAGER PRIOR TO ITS REMOVAL. FAILURE TO DO SUCH COORDINATION WILL RESULT IN G.C.'S MONETARY FINE IN THE EQUIVALENCE OF THE COST REPLACEMENT VALUE OF THE EXISTING I l / U SECURITY SYSTEM. 10.G.C. IS TO NOTIFY TENANT IMMEDIATELY OF ANY SEVERE DISCREPANCIES OR IRREGULARITIES DISCOVERED DURING CORTIAND MORGAN DEMOLITION WHICH MIGHT AFFECT THE CURRENT STORE DESIGN. G.C. IS TO PAY SPECIAL ATTENTION TO AVAILABLE STATE OF IDAHO HEIGHT FOR INTENDED CEILING ELEVATION, MECHANICAL DUCTWORK AND RECESSED LIGHTING. 11.G.C. IS TO CUT ALL NECESSARY OPENINGS FOR ANY REQUIRED PURPOSE AND REPAIR, WHERE NECESSARY. AFTER CUTTING IN SO FAR AS POSSIBLE ALL PROTRUSIONS, MARKS, CRACKS, OR OTHER EVIDENCE OF DAMAGED, DEFICIENT C- 1 OR UNSAFE CONDITION, ANY PARTS WHICH ARE SPLIT, CRACKED, SPALLED, CHIPPED, BROKEN, MISSING, OUT OF LINE PROJECT COORDINATION LCP 19 ADJUSTMENT MECHANICALLY STRUCTURALLY UNSAFE OR UNSOUND, BENT, TORN, OTHERWISE DEFICIENT OR IN C�,DDTECI-I 17 I INJURED IN ANY MANNER SHALLL BE REMOVED, REPLACED, REPAIRED OR RESTORED SATISFACTORILY AS DIRECTED BY 1 TENANT'S CONSTRUCTION MANAGER. 20 225 OARIAND ROM.SUNE 105 TIE(Sfi0)M-5670 LP7 12.G.C. IS RESPONSIBLE FOR REMOVING ALL DEMOLISHED ITEMS, DEBRIS, ETC., FROM SITE. G.C. IS RESPONSIBLE FOR SOUTH WNDSO.Cr OW4 FAR:(ew1785-56110 PROPERLY DISPOSING OF ALL ITEMS ACCORDING TO ANY APPLICABLE LOCAL OR STATE ORDINANCES. I TTe III I RETAM ioo ii WALL TYPES: W T LL `\ SYM DESCRIPTION 0 C0 15.R T B I III i W I— (y) CV A.) A.) EXISTING WALL CONSTRUCTION: CO 00 STOCK RM�� EXISTING EXTERIOR MASONRY BRICK VENEER OVER WOOD STUD FRAMING, FULL !> THICKNESS INSULATION AND i" GYP. BD. TO UNDERSIDE OF DECK. `' w Q I I EXISTING INTERIOR WALL O O I - - - i I J A.) A.)EXISTING INTERIOR PARTITION OR ELEMENT TO REMAIN. C J z L J .� z I I EXISTING INTERIOR WALL Z J a c3 i i - A.) A.)EXISTING INTERIOR PARTITION OR ELEMENT TO BE REMOVED. O LL LL ^` Z v) Cd I i I Q 0 Q EXISTING FLOOR PLAN /SELECTIVE DEMOLITION NOTES: U r L__-J STOREFRONTS- [1] EXISTING STOREFRONT TO REMAIN INCLUDING ENTRY DOORS, STOREFRONT TO BE CLEANED TO LIKE NEW CONDITION. I I RETAIL 100 �2 REMOVE EXISTING WALL MOUNTED MERCHANDISING SYSTEMS, RECESSED WALL STANDARDS, RELATED WALL O FURRING, MILLWORK, TRIM ETC. THROUGH-OUT THE RETAIL AREA. C 1 �3 REMOVE EXISTING INTERIOR PARTITIONS, CORNER FILLERS AND WING WALLS WHERE INDICATED BACK TO DEMISING cd 2 3 WALL. ALL ELECTRICAL TO BE REMOVED BACK TO POINT OF SERVICE AND MADE SAFE. ��L ® EXISTING CASH DESK AND BACKWRAP TO BE REMOVED. ALL ELECTRICAL AND DATA TO BE REMOVED BACK TO POINT fn SI OF SERVICE AND MADE SAFE. CUT BACK CONDUITS AND PATCH CONCRETE FLOOR. f w C- (TYP) 5 EXISTING FLOOR IS SEALED CONCRETE, REMOVE ALL WALL BASE. SLAB IS TO BE CLEAN, PROVIDE FLOOR PREP SCRAPE, O 11 . -,� GRIND, CLEAN, FOR A SMOOTH, AND LEVEL, READY FOR NEW TENANT FLOORING. v O 17 I 2 :3:] FITTING:101,102 F u I C- _-- _J © REMOVE EXISTING FITTING ROOM PARTITIONS SHOWN DASHED AND DOOR ETC. ALL ELECTRICAL TO BE REMOVED BACK TO POINT OF SERVICE AND MADE SAFE. O - - - - - - - - - - - - J �7 EXISTING FLOOR IS SEALED CONCRETE, REMOVE ALL WALL BASE. SLAB IS TO BE CLEAN, PROVIDE FLOOR PREP SCRAPE, STORE NUMBER i I GRIND, CLEAN, FOR A SMOOTH, AND LEVEL, READY FOR NEW TENANT FLOORING. HALL 103 1369 EXISTING HALL TO REMAIN, REMOVE DOOR, AREA OF PARTITIONS SHOWN HIDDEN. __ I EXISTING DRINKING FOUNTAIN TO REMAIN. I Fu""11 ISSUE EXISTING REAR SERVICE DOOR TO REMAIN. 'A'-ISSUE:PRELIMINARY DATE: 4/26/22 11 EXISTING FLOOR IS SEALED CONCRETE, REMOVE ALL WALL BASE. SLAB IS TO BE CLEAN, PROVIDE FLOOR PREP SCRAPE, 'B'-ISSUE:LL REVIEW BID SET GRIND, CLEAN, FOR A SMOOTH, AND LEVEL, READY FOR NEW TENANT FLOORING. / 12 13 TOILET ROOM:104,105 DATE: 5/6T S TOILFf RM 105 I a'-°��Tyl" I I I I I 'C'-ISSUE:PERMIT SET 12 EXISTING TOILET ROOMS TO REMAIN AND BE REFINISHED. G.C. TO REMOVE EXISTING PLUMBING FIXTURES AND DATE: 6/14/22 2 3 ACCESSORIES FROM ROOMS FOR ROOM REFINISHING, PLUMBING FIXTURES WILL BE REPLACED WITH TENANT SPECIFICATION 'D'-ISSUE: 9 IN EXISTING LOCATIONS. IF FRP IS IN GOOD CONDITION LEAVE FOR REUSE. DATE: 21 13 EXISTING FLOOR IS SEALED CONCRETE, REMOVE ALL WALL BASE. SLAB IS TO BE CLEAN, PROVIDE FLOOR PREP SCRAPE, 'E'-ISSUE: DISPLAY WINDOW _ _ GRIND, CLEAN, FOR A SMOOTH, AND LEVEL, READY FOR NEW TENANT FLOORING. DATE: 1 STOCKROOM:106 'F'—ISSUE: DATE: I 14 REMOVE EXISTING SURFACE MOUNTED STANDARDS, SHELVES, AND DESK. a SHEET TITLE 12 13 15 EXISTING FLOOR IS SEALED CONCRETE, REMOVE ALL WALL BASE. SLAB IS TO BE CLEAN, PROVIDE FLOOR PREP SCRAPE, GRIND, CLEAN, FOR A SMOOTH, AND LEVEL, READY FOR NEW TENANT FLOORING. TaLET RM 1D4 — EX.CONDITIONS 16 REMOVE ALL EQUIPMENT IF ANY LEFT ABANDONED. REMOVE ASSOCIATED ELECTRICAL TEL. AND DATA BACK TO POINT OF SERVICE AND MAKE SAFE. FLOOR PLAN 17 REMOVE MISCL. WING WALL PARTITIONS, ALL ELECTRICAL TO BE REMOVED BACK TO POINT OF SERVICE AND MADE SELECTIVE DEMO L _IJ I I -,� " CITY APPROVED PLANS 18 SLAB TO BE CLEAN, SMOOTH, AND LEVEL READY FOR NEW TENANT FLOORING. SCALE 1/4" =1'-0" O - _ -L - - Reviewed for Code Compliance 19 REMOVE EXISTING LIGHT STAT LIGHTING CONTROL PANEL TO BE REPLACED WITH TENANT LCP. / PLANS MUST B E O N J O B SITE 20 EXISTING ELECTRICAL PANEL TO REMAIN. SEE ELECTRICAL DRAWINGS FOR SCOPE OF WORK. SHEET NUMBER L------:777J7 DISPLAY WINDOWS EXISTING CONDITIONS FLOOR PLAN SELECTIVE DEMOLITION PLAN FOR ALL INSPECTIONS 21 EXISTING DISPLAY WINDOW'S AREAS TO REMAIN, REMOVE WALL BASE. /40,1 SCALE U4'-1-0' NORT__ 4 5 6 1 2 3 DATE: 4/26/22 MGM YvE RETAL JOB NO: 22-010 ROOM TYPE O FTFTNC CL.3 O2 CL1 O HEIGHT MISC. HEIGHT MISC. DRAWN: STAFF n'-0 cYP. 16-7 DECK CEILING LIGHTING DEMOLITION CEILING TO REMAIN CHECKED: CM EXISTING TRACK LIGHT FIXTURES TO BE REMOVED ® EXISTING SOFFIT MOUNTED RECPT. TO BE REMAIN L$1$J EXISTING PENDANT 2 X 2 LIGHT FIXTURE TO BE REMOVED 4601 EXISTING EMERGENCY LIGHT TO REMAIN I I 7.�/N� EXISTING RECESSED DOWNLIGHTS TO BE REMOVED ® EXISTING EXHAUST FAN/LIGHT TO REMAIN �jf V UO F1 5-Fl-61 EXISTING SPEAKERS TO BE REMOVED C O R T L A N D ROOM Tr - - --- ------�-------$- - -------fir----�--- -----�----�---�_� - 33 E/X N 0 R G A N w • EXISTING STRIP LIGHT FIXTURE TO BE REMOVED ® EXISTING EXIT FIXTURE TO REMAIN. DE114H YMc�3 ARCH ITECT n'-0 GSC - :!,f] EXISTING EXIT FIXTURE TO BE REMOVED ■ 1 711 N. FIELDER RD. ARLINGTON, TX 76012 �•::� EXISTING DOUBLE HEAD EMERGENCY FIXTURE TO BE REMOVED IN- I I - - - - - - - - - PH: (817) 635-5696 FAX: (817) 635-5699 $ EXISTING RECESSED EMERGENCY LIGHT TO BE REMOVED EXISTING SUPPLY AND RETURN DIFFUSERS TO BE REMAIN +� LICENSED (�® I ARCHITECT AR-2098 I - I - - - - - - - - - - J EXISTING CEILING TYPES: w © L L — — — — s?— — — — — CL1 EXISTING OPEN TO STRUCTURE CEILING PAINTED — rCGRTLANp MGRGAN - - - I - WHITE STATF OH IHAHG r�T$� ® EXISTING 2 X 4 ACOUSTICAL CEILING. 1T — I � EXISTING GYP. BD. CEILING PROJECT COORDINATION ® EXISTING OPEN TO STRUCTURE CEILING 225 OAgvm pap,SUITE 105 m:(eep11 M-Sa0 1 UNFINISHED. S01RH WDSOR,Cr 06074 FAIL(VH lu-= r -- I I EX.CEILING PLAN /SELECTIVE DEMOLITION NOTES: W LL II ``1'1 I EX RETAIL AREA CO Wm Mp U) ROOM3 14TYPE I — II — — `------- — — — — — — I C LL v) STOCK CLA _ --�-- --�-- - -- -- --� -- -- L 1Ej REMOVE ALL EXISTING PENDANT SUSPENDED LIGHT FIXTURES, AND SUSPENDED TRACK W I— c N HEIGHT MISC. r I LIGHTING THROUGH OUT. ALL ELECTRICAL TO BE REMOVED BACK TO POINT OF SERVICE. N 15'-T DECK ' �2 REMOVE EXIT SIGNS AND EMERGENCY LIGHTING ALL ELECTRICAL TO BE REMOVED BACK r.F TO NEAREST J-BOX AND MADE SAFE. w i V Ili ❑3 EXISTING HVAC DUCT WORK TO REMAIN. SEE MECHANICAL DRAWINGS FOR MORE INFO. c M 0 co J EX.FITTING ROOMS: (L M J 0) �I ®REMOVE EXISTING GYP. BD. CEILINGS O J < %� �5 REMOVE ALL LIGHT FIXTURES AND EMERGENCY LIGHT FIXTURES. ALL ELECTRICAL TO BE 01 REMOVED BACK TO POINT OF SERVICE AND MADE SAFE. � (�]� U ©EXISTING HVAC DUCT WORK TO REMAIN. SEE MECHANICAL DRAWINGS FOR MORE INFO. Z i Z cd - h� - - - - - - - - - I DL EX.HALL: U C!) REMOVE ALL LIGHT FIXTURES UNLESS NOTED OTHERWISE ALL ELECTRICAL TO BE REMOVED BACK TO POINT OF SERVICE AND MADE SAFE. - JL' - - i ®EXISTING HVAC DUCT WORK TO REMAIN. SEE MECHANICAL DRAWINGS FOR MORE INFO. `N LI � >� � � 9❑EXISTING EMERGENCY LIGHT FIXTURE AND EXIT SIGN TO REMAIN. r-- - - - - - - - I I EX.TOILET ROOMS: C O EX/Y r�H`T•8'� �' 10 EXISTING TOILET ROOMS ACOUSTICAL CEILING GRID TO REMAIN, REMOVE AND REMOVE C EXISTING ACOUSTICAL TILES TO BE REPLACED WITH NEW. REMOVE AND REPLACE LIGHT L II I L 1 J FIXTURE IN EXISTING LOCATION. SEE CEILING PLAN A2.1 m I to _ T$� _ _ _ _ - ', I 11 HVAC DIFFUSERS AND DUCT WORK TO REMAIN AND OR BE MODIFIED. COORDINATE L$1$J 1 WITH MECHANICAL DRAWINGS FOR ALL NEW WORK. O ul -�i I - n - - - - - - ' U O I EX.STOCKROOM REMOVE STRIP LIGHT FIXTURES, EMERGENCY AND EXIT LIGHT FIXTURES. ALL ELECTRICAL TO BE REMOVED BACK TO POINT OF SERVICE AND MADE SAFE. - - - J 13 HVAC DIFFUSERS AND DUCT WORK TO REMAIN AND OR BE MODIFIED. COORDINATE STORE NUMBER WITH MECHANICAL DRAWINGS FOR ALL NEW WORK. 1~� 15 ��� 15 14 EXISTING EMERGENCY LIGHT FIXTURE AND EXIT SIGN TO REMAIN. i�G� Ewn I I II I I V 10 1, EX.DISPLAY WINDOWS: TOLEfIM1 CL2 II AL ' 15 REMOVE EXISTING RECESSED DOWN LIGHTS AND TRACK LIGHTING. RECESSED DOWN ISSUE EIGHT MISC. — — — — — — — — — LIGHTING AND TRACK LIGHTING TO BE REPLACED ONE FOR ONE WITH TENANT 'A'-ISSUE:PRELIMINARY 8'-0' ACT 1 RECESSED DOWN LIGHT SPECIFICATION. DATE: 4/26/22 F T _ EXISTING SOFFIT MOUNTED RECPT. TO BE REMAIN 'B'-ISSUE:LL REVIEW / BID SET ® I DATE: 5/6/22 'C' DATE: PERMIT 6/14/22 cc 13 'D'-ISSUE: M TYPE 10101 � DATE: 'E'-ISSUE: ID�AY MISC. JL - I DATE: 'I _ _ _ ® IF II `- L--- --- ---�_ SHEET TITLE 'D " - �r - _� - - - - - - - CITY APPROVED PLANS EX.CONDITIONS/ IROOM TYP I I I II SELECTIVE DEMO. TOLEfRA2 CL2 MI L L 1 I _ _ _ _ - _ _ - J Reviewed for Code Compliance IL e-0 ACT I I CEILING PLAN PLANS MUST BE ON JOB SITE SCALE --_ _ _ — - FOR ALL INSPECTIONS 1/4" =1'-0" - _ _ 6 y L---- J SHEET NUMBER ROOM TYP -------- -- HALL CI-4 EX. CONDITIONS / SELECTIVE DEMO.CEILING PLAN / PLAN MISC. A O,2 H IGHT 16'-S' DECK SCALE:1/4'-T-O• NORTH Pagii 59'-0j" DATE: 4/26/22 B y LEASE DIMENSION ,—------------------- , JOB N0: 22-010 OR0101 DRAWN: STAFF 2 ' — — 1 1 NAME � � A31.6 ; r , ' A3.0 CHECKED: CM ----- ------- 1 20• #4 BARS @ 12'O.C. ALTERNATING DOWEL IN REBAR SET IN EPDXV TAPE SEAM MUMO 24 25 _ ADD BENCH PER iv 1 I , NEW CONCRETE NEw VAPOR BARRIER DOM AREA 1003F. 1 / °p ICC All 7.1-2009 1 1 / m I SECTION 903. , , OVERLAP ALIGN EX.VAPOR BARRIER V.I.F. C G R T L A N G NAME EX.SLAB N G R G A N DISPLAY - A R C H I T E C T i 1'-2" , --------- , 711 N. FIELDER RD. 1 X—lf p X X—X ARLINGTON TX 76012 16 n 1a 1 6 1 PH: (817) 635-5696 ROOM AREA , 5. 5 I FAX: (817) 635-5699 105 60 SF. I 1 - -- , 1 °� , AM o o 4R. �� LAP LENSED� � ARCHITECTAR-2098COMPACTED CONDUITS/OR PIPING bSUB-GRADEcc 1_11 i -4 - - - �_ _ Ji1 TRENCH REPAIR DETAILO. TL , 2'-8" 1 SCALE 3'-T-0' 1 � 5. 1 I PROJECT COORDINATION M�fl (ADD 01 , 11 22 1 1 225 mum N�IN=n a�i I� F7°Ac�(fiONu)w-sM LP1 I WALL TYPES, 1 U , I I I 1 SYM DESCRIPTION BUILDING TTB I 2 3 I A.) EXISTING WALL CONSTRUCTION: ROOwMO ARAr SP A. EXISTING EXTERIOR MASONRY BRICK VENEER OVER EXTERIOR SHEATHING AND L W �'^ NAMSALES EA C�1 UNDERSIDE OFWOOD STUD RDECK. PATCH AMING FULL TA AND REPAIRNESS GYP. ED. READY AND 'FOR PAINT (PROVIDE r O yJ LEVEL-4- FINISH) U CO W H 1;0 r 4 i 1 CO M EXISTING INTERIOR PARTITIONS: A.) A.) EXISTING 3 5/8" METAL STUDS ® 16" O.C. AND 5/8" TYPE "X" W Q ' GYP. BD. G.C. TO PATCH AND REPAIR. (PROVIDE LEVEL "4" FINISH) I z — 6 1 Q 0 C NEW INTERIOR PARTITIONS (NOT RATED) L J o © _ _ _ _ _ _ _ J ' TA7771T177717,A.) AJ 3 5/8" X 20GA METAL STUDS O 16" O.C. WITH FIBERGLASS SOUND BATT J J r ' INSULATION WHERE SHOWN IN DETAILS ALE GYP. BD. (PROVIDE LEVEL "4" FINISH) Z _j Q 0 LL LL N Install portable fire extinguishers to meet the Q Z Q I I , Requirements of 2015 IFC 906.1 /NFPA 10. - Install a 5 lbs.portable fire extinguisher with U A minimum rating of 2A-10B. The travel distance from an extinguisher Shall not exceed 75 feet.The extinguisher Must be mounted in a conspicuous location F L 1 Unobstructed and unobscured from view N 1 I C 0 i CONSTRUCTION PLAN NOTES: m I STOREFRONT: TOILET ROOMS:103,104 0 L =I 3-2" EXISTING STOREFRONT ENTRY DOORS AND DISPLAY WINDOWS TO REMAIN. SEE DOOR 14 EXISTING TOILET ROOM TO REMAIN FIXTURES AND ACCESSORIES REPLACED. SCHEDULE FOR ENTRY DOOR HARDWARE REPLACEMENT REQUIREMENTS. PARTITIONS TO PATCHED AND REPAIRED TO LEVEL 4 FINISH. PROVIDE AND F M O 4 I INSTALL ELECTRIC HAND DRYER AND OTHER TENANT ACCESSORIES. B SALES AREA:100 SEE SHEET A3.3 -- I , 2❑G.C. TO PATCH AND REPAIR EXISTING PERIMETER WALLS GYP. BD. 15 G.C. TO PREP CONCRETE SLAB READY FOR NEW TENANT FLOOR FINISH. SLAB O - - 3 I J 1 PROVIDE LEVEL 4 FINISH. TO BE LEVEL AND SMOOTH READY FOR TENANT'S FLOOR FINISH. STORE NUMBER - �I D i �3 G.C. TO PROVIDE NEW CORNER FILLERS, AND INTERIOR PARTITIONS AS DIMENSIONED, OFFICE:105 / 1 PARTITIONS TO BE TAPED, COMPOUNDED, SANDED READY FOR TENANT FINISHES. / 69 '' / © " 2•_B" , LEVEL 4 FINISH. 16 G.C. TO PROVIDE OFFICE PARTITIONS. ALL PARTITIONS TO BE TAPED, COMPOUNDED, __�.V{{/ l SANDED READY FOR TENANT FINISHES PROVIDE LEVEL 4 FINISH TO 6" ABOVE 1 Z- _ I 1 ®EXISTING SALES/STOCKROOM PARTITION TO REMAIN WITH MODIFICATION WHERE FINISHED CEILING. SEE SHEET A3.5 INDICATED. PROVIDE NEW DOOR, FRAME, AND HARDWARE. PARTITIONS TO PATCHED 17 G.C. TO PROVIDE ELECTRICAL DEVICES INCLUDING, QUAD RECEPTACLES, 24 25 V 1 AND REPAIRED FOR TENANT FINISHES. ("LEVEL 4 FINISH" TO DECK ABOVE. ISSUE ROOM AREA I ) DUPLEX RECEPTACLES, TELEPHONE J-BOX/CONDUIT AND FAX J-BOX/CONDUIT. I \ y 'A'-ISSUE:PRELIMINARY 108 1 y 1 , SEE OFFICE DETAIL SHEET A3.5 FOR EXACT LOCATIONS OF DEVICES AND DATE: 4/26/22 \ 5 �5 PATCH AND REPAIR EXISTING COLUMN ENCLOSURES READY FOR PAINT. COORDINATE WITH ELECTRICAL DRAWING SHEET E2.0 NAME , 1-= , I PROVIDE LEVEL 4 FINISH. DISPLAY ' �\ I ' I 1 18 G.C. TO PREP CONCRETE SLAB READY FOR NEW TENANT FLOOR FINISH. 'B'-ISSUE:LL REVIEW BID SET / DATE: 5/6/22 PROVIDE AND INSTALL CASHWRAP CONDUITS FOR CASHDESK BELOW FLOOR. SEE SLAB TO BE LEVEL AND SMOOTH READY FOR TENANT'S FLOOR FINISH. 14 15 _ ELECTRICAL DRAWINGS FOR REQUIRED CONDUITS AND SIZES. 'C'-ISSUE:PERMIT SET OOM AREA r 2 STOCKROOM:106 DATE: 6/14/22 104 78 S.F. I 5. , W7 PREP CONCRETE SLAB READY FOR NEW TENANT FLOOR FINISH. SLAB TO BE LEVEL AND 19 PROVIDE ELECTRICAL DEVICES FOR EMPLOYEE BRAKE AREA REFRIG, MICROWAVE 'D'-ISSUE: NA I 11 a '�' , SMOOTH READY FOR TENANT'S FLOOR FINISH. AND WATER BUBBLER. SEE ELECTRICAL DRAWING SHEET E2.0 DATE: INLET ROOM N—— 1 FITTING ROOM:101 'E'-ISSUE: G.C. TO PATCH AND REPAIR EXISTING GYP. BD. PARTITIONS. PROVIDE LEVEL 4 DATE: 1 1 ®G.C. TO PROVIDE AND INSTALL FITTING ROOM PARTITIONS TAPED, COMPOUNDED, SANDED FINISH TO 6" ABOVE FINISH CEILING. SEE WALL TYPE SCHEDULE. 1 1 AND PAINTED PER TENANT SPECIFICATIONS. 'F'-ISSUE: 14 15 21 PREP CONCRETE SLAB READY FOR NEW TENANT FLOOR FINISH. SLAB TO BE DATE: M A A I 3 __ I �9 G.C. TO PROVIDE AND INSTALL ROUGH OPENING FOR NEW FITTING ROOM DOOR SUPPLIED 1 1 BY TENANT INSTALL BY TENANT G.C. LEVEL AND SMOOTH READY FOR TENANT'S FLOOR FINISH. XXi 75 S.F. 1 ' AME v 4 1'-2" I HALL:102 22 EXISTING ELECTRICAL PANEL AND TELEPHONE SYSTEM TO REMAIN. SEE ELECTRICAL TGIETROOM _-L-- I 1 1 DRAWINGS. CITY APPROVED PLANS --- 1 I 10 G.C. TO PATCH AND REPAIR EXISTING HALL AREA GYP. BD. PARTITIONS. PROVIDE LEVEL 4 FINISH. 23 PROVIDE AND INSTALL LIGHTING CONTROL PANEL. SEE ELECTRICAL DRAWINGS. Reviewed for Code Compliance E%ISTING DRINKING FOUNTAIN TO REMAIN. 1 ® 1 _6•• aD i N 1 PLANS MUST BE ON JOB SITE EXISTING REAR SERVICE DOOR TO REMAIN. PROVIDE HARDWARE PER DOOR SCHEDULE. DISPLAY WINDOWS°107,10S J SEE C1.2. FOR ALL INSPECTIONS r _ -- i� � 24 G.C.TO PATCH AND REPAIR EXISTING GYP. BD. PARTITIONS. PROVIDE LEVEL 4 ------------- , FINISH TO 6" ABOVE FINISH CEILING. SEE WALL TYPE SCHEDULE. OFfl 1 13 G.C.TO PREP CONCRETE SLAB READY FOR NEW TENANT FLOOR FINISH. SLAB TO BE LEVEL AND SMOOTH READY FOR TENANT'S FLOOR FINISH. 25 EXISTING DISPLAY WINDOWS TO REMAIN. 1 1013 rF A3.3 ROOM AREA I 9-3Z L_ - 102 162 S.F. ------NAME HALL CONSTRUCTION PLAN PLAN ,—-----------------------—- A1.1 SCALE 1/4'-T-0' NORTH Raae 6'-8" 46'-0" DATE: 4/26/22 0 6qE O O FLOOR FINISH INSTALLATION: JOB NO: 22-010 OREANE�L. DRAWN: STAFF 7 B.F. NA A. ALL FLOOR COVERINGS SHALL BE INSTALLED PER MANUFACTURERS STANDARD DETAILS AND SPECIFICATIONS. CHECKED: CM ROOM - - - - - - - - - - B. THE G.C. IS RESPONSIBLE TO PREPARE THE EXISTING FLOOR FOR THE PROPER INSTALLATION OF THE FLOOR COVERING MATERIALS INDICATED ON THE PLAN. CONSULT MANUFACTURES SPECIFICATIONS FOR SURFACE PREPARATION REQUIREMENTS FOR EACH FINISH LISTED IN THE FINISH SCHEDULE. f\I V U 0 C. THE G.C. IS RESPONSIBLE FOR VERIFYING THAT THE CONDITION OF THE BASE FLOOR MEETS THE U Il I MANUFACTURES INSTALLATION REQUIREMENTS PRIOR TO THE INSTALLATION OF THE FLOORING MATERIAL. 22 23 24 AREA C 0 R T L A N D 107 100 BF D. THE G.C. SHALL PERFORM A RELATIVE HUMIDITY TEST IN ACCORDANCE WITH MFG REQUIREMENTS AND NAME ASTM F2170-16B. IF MOISTURE CONTENT OF FLOOR EXCEEDS THE MFG RECOMMENDED ALLOWANCES. THE MI 0 R G A N DISPLAY FLOORING CONTRACTOR SHALL PROVIDE THE RECOMMENDED SURFACE PREPARATION PER THE MFG'S A R C H I T E C T SPECIFICATIONS. I E. ALL THRESHOLDS AND FLOOR TRANSITION SHALL BE 1/2" MAX. HEIGHT. 711 N. FIELDER RD. 15 16 17 u' ARLINGTON, TX 76012 DM JAR EA F. ALL STORES IN COASTAL REGIONS SHALL USE A HIGH HUMIDITY ADHESIVE PH: (817) 635-5696 105 60 BF. FOR SLAB MOISTURE CONTROL. G.C. TO PROVIDE "SPRAYLOCK 6500 PLATINUM" ADHEASIVE. FAX: (817) 635-5699 AM OH9CE I G. GC SHALL SCRAPE FLOOR CLEAN OF ALL OLD FLOOR COVERINGS AND ADHESIVES; PATCH MINOR HOLES AND I BLEMISHES; AND SAND, SWEEP, AND CLEAN THE SUBSTRATE TO ENSURE PROPER ADHESION OF THE LICENSED MATERIAL TO BE INSTALLED. GC SHALL ALSO INCLUDE PREPARATION OF ANY PLUMBING, MECHANICAL, OR ARCHITECT ELECTRICAL TRENCHES ASSOCIATED WITH THE PROJECT. AR-2oS8 I Cr B.F. REPAINT UPON INSTALLATION. SEE DETAIL 2/A1.2b. SOUTH WINDSGConrlaxx MDRRA OUTSIDE CORNERS. SEE FINISH SCHEDULE FOR SPECIFICATION. x STATF Of IDAHO SALES AREA 100 �1 G.C. TO PAINT SALES AREA (PT7) SEE ELEVATIONS PROVIDE AND INSTALL WHITE CORNER GUARDS AT ALL PROJECT COORDINATION I I ❑2 STAGGERED STALL PATTERNNANT BUFFENDOR FLOOR AFTERSD LVT WOOD PLANK NBTALLATION AND CAULK ATFLOORING STOREF IN RONTSALES AREA. INSTALL IN C�,DDTech 18 19 20 21 oDM AREA I �3 G.C. TO INSTALL TENANT VENDOR SUPPLIED BASE (B1) THROUGHOUT THE SALES FLOOR AREA. PUTTY AND 225 OAKIAND Ran,SUITE 105 TEL(eso)ray-5er0 IN581 R, Dea4 FAX:(ew,1u-seep NAM E STOCKROOM ® G.C. TO PROVIDE AND INSTALL WHITE VINYL CORNER GUARDS FROM TOP OF BASE 6' A.F.F. AT ALL OUT I I SIDE CORNERS AND COLUMN ENCLOSURES. SEE FINISH SCHED. FOR SPEC. I I I ❑5 G.C. TO PROVIDE CAULK / SEALANT AT JOINTS OF ALL UNLIKE SURFACES. 1 FITTING ROOM 101 W T LL I � 1.2 © G.C. TO PAINT FITTING ROOM (PT1) SEE ELEVATIONS. SEE FINISH SCHEDULE FOR SPECIFICATION. Cf) ('7 G.C. TO INSTALL TENANT VENDOR SUPPLIED BASE (B1) THROUGHOUT THE SALES FLOOR AREA. PUTTY AND W CIO I I REPAINT UPON INSTALLATION. SEE DETAIL 2/A1.26. rj _ © G.C. TO INSTALL TENANT VENDOR SUPPLIED LVT WOOD PLANK FLOORING (FC1) IN SALES AREA. INSTALL IN W STAGGERED PATTERN. BUFF FLOOR AFTER INSTALLATION AND CAULK AT STOREFRONT. � � — � HALL'102 Q 0 C I I ❑ FG.C. TO PAINT RP TO REMAIN HALL ALEANALLS (PT1) PER DRAWINGS. SEE FINISH SCHEDULE FOR PAINT SPEC. EXISTINGPT J O10 G.C. TO INSTALL TENANT VENDOR SUPPLIED LVT VINYL WOOD PLANK FLOORING (FC2). Z J Q INSTALL IN STAGGERED PATTERN EllG.C. TO INSTALL TENANT VENDOR SUPPLIED BASE (B2) W Z U 12 G.C. TO PROVIDE CAULK / SEALANT AT JOINTS OF ALL UNLIKE SURFACES. Z �l Q I I TOILET ROOM:1W,104 U (A 13 G.C. TO PAINT TOILET ROOM: PAINT (PT2), EXISTING FRP TO REMAIN, CLEAN. 14 INSTALL TENANT VENDOR SUPPLIED SHEET VINYL FLOORING (FC3) WITH INTEGRATED 6" BASE. SEE FINISH SCHEDULE FOR SPECS. SEE SHEET A3.3 ELEVATIONS. I I � I - I OFFICE:105 L HI 15 G.C. TO PAINT (PT2) PER TENANT DRAWINGS. SEE FINISH SCHEDULE FOR PAINT SPEC. � O 16 G.C. TO INSTALL TENANT VENDOR SUPPLIED LVT FLOORING (FC2), INSTALL IN A STAGGERED PATTERN. I I 17 G.C. TO INSTALL TENANT VENDOR SUPPLIED VINYL COVE BASE (B2) 0 SI I I STOCKROOM:1W [, N 18 G.C. TO PAINT (PT2) PER TENANT DRAWINGS. SEE FINISH SCHEDULE FOR PAINT SPEC. F U O -- 19 G.C. TO INSTALL TENANT VENDOR SUPPLIED LVT FLOORING (FC2), INSTALL IN A STAGGERED PATTERN. I I O20 G.C. TO INSTALL TENANT VENDOR SUPPLIED VINYL COVE BASE (B2) STORE NUMBER 21 G.C. TO PROVIDE AND INSTALL ALUM CORNER GUARDS. SEE FINISH SCHEDULE FOR SPECIFICATION. Al Nrz DISPLAY WINDOWS:107,108 1369 13 14 ROOM ARE ri G.C. TO PAINT (PT1) PER TENANT DRAWINGS. SEE FINISH SCHEDULE FOR PAINT SPEC. ISSUE 104 78 SF. I NAM 'A'-ISSUE:PRELIMINARY T01-Ef Fi001A I \ Y3 G.C. TO INSTALL TENANT VENDOR SUPPLIED LVT FLOORING (FC1), INSTALL IN A STAGGERED DATE: 4/26/22 7,_ „ \ PATTERN. 'B'-ISSUE:LL REVIEW / BID SET 24 REPAINT UPON 22 23 NSTALLATIONN SEE DETAILS 2/AASZb(B1) THROUGHOUT THE SALES FLOOR AREA. PUTTY AND DATE: 5/6/22 'C'-ISSUE:PERMIT SET 24 I 1.2 RE)108 DATE: 6/14/22 100 3F REA I 'D'-ISSUE: . PIR DATE: NAME DISPLAY 'E'-ISSUE: DATE: 'F'-ISSUE: DATE: 13 14 1.2 SHEET TITLE ROOM AREA 103 75 S.F. n NAMEROOM I FINISH PLAN PFRPIFC3 CITY APPROVED PLANS SCALE ] 7 z Reviewed for Code Compliance PLANS MUST BE ON JOB SITE 1/4" = 1'-O" �?fl FOR ALL INSPECTIONSSHEET NUMBER A1.2a FLOOR FINISH PILM PLAN SC CAALE Vf-T-W r1kir NORTH Page 1 DATE: 4/26/22 JOB NO: 22-010 FINISH SCHEDULE: DRAWN: STAFF PAINT CHECKED: CM MARK LOCATION TYPE STYLE DESCRIPTION MFG. MFG. # REMARKS PT SALES AREA PAINT EXTRA WHITE PAINT: SATIN LATEX SHERWIN 7006 SUPERPAINT SERIES WILLIAMS PROVIDE PRIMER AND (2) FINISH COATS OF PAINT. BY G.C. STOREFRONT, SALES AREA WOOD TRIM, PROVIDE PRIMER AND (2) FINISH COATS OF PAINT. BY LANDLORD EXTRA WHITE INT:SEMI GLOSS SHERWIN HALL, OFFICE, TOILET ROOM, AND PAINT SUPERPAINT SERIES WILLIAMS 7006 N PT2 TOTE: WOOD TRIM PRODUCTS FROM MILLSHOP ARE PRIMERED ONLY. STOCKROOM ENANT G.C. TO PAINT ALL TRIM (PT2) UPON INSTALLATION. FLOOR FINISHES C O R T L A N 0 MARK LOCATION TYPE COLOR/STYLE/ DESCRIPTION MFG. MFG. # REMARKS BUFF/GRAIN/LUXURY VINYL WOOD M 0 R G A N FC1 SALES AREA VINYL ID FLOORING STAGGERED JOINT SHAW 64140/0502V PROVIDED BY TENANT INSTALLED BY G.C.PATTERN A R C H I T E C T FC2 HALL, OFFICE SOLID CHISEL/PLASTER /LUXURY VINYL AND STOCKROOM VINYL WOOD FLOORING STAGGERED JOINT SHAW 53510/0566V PROVIDED BY TENANT INSTALLED BY G.C. 711 N. FIELDER RD. PATTERN ARLINGTON, TX 76012 SHEET PH: (817) 635-5696 FC3 TOILET ROOM VINYL RESTORE/VITALITY SHAW 73518/0873V PROVIDED BY TENANT INSTALLED BY G.C. FAX: (817) 635-5699 STOCKROOM LOCATE AT SOLID RED/PIGMENT/LUXURY VINYL USED IF ELECTRICAL IS IN THE STOCKROOM ONLY, SEE PLAN. FCS STOCKROOM ELECTRICAL VINYL FLOORING STAGGERED JOINT SHAW 65855/0503V SUPPLIED AND INSTALLED BY G.C., WAX AND BUFF PATTERN s WALL BASE MARK LOCATION TYPE STYLE/DESCRIPTION MFG. MFG. # REMARKS B1 SALES AREA, HALL WOOD 1/2"XX 4" O QUARTER ROUND SHO MILLSHOP OD BASE, WITH SUPPLIED BY TENANT INSTALL BY TENANT G.C. THE BASE IS PRE-FINISHED PT2, G.C.TO REPAINT ALL AFTER INSTALLATION B2 HALL, OFFICE SOLIDCEMENT 4" HIGH COVE BASE SHAWAND STOCKROOM VINYL ( ) 148VS/00750 PROVIDED BY TENANT INSTALLED BY G.C. WAINSCOT MARK I LOCATION TYPE STYLE/DESCRIPTION MFG. MFG. # REMARKS FRP1 HALL, TOILET ROOM, AND TBD WHITE PEBBLED FRP PANELS STRUCTO- PEBBLED PROVIDED AND INSTALLED BY G.C. PROJECT COORDINATION MOP SINK AREA GLASS 1130 PLASTIC LAMINATE CADDTuri SYMBOL LOCATION TYPE STYLE/DESCRIPTION MFG. MFG. # REMARKS 775 ON(UND ROAD,SLIDE IDS TEL(S66 787-5670 SOUTH WINDSOR.CT 06074 FAX:(86�)761-M pL1 SALES STOCK DOOR/ SALES SIDE, PLASTIC STOREFRONT PLATFORM LAMINATE DESIGNER WHITE WILSONART D354-60 PROVIDED AND INSTALLED BY G.C. pL2 FITTING ROOM BENCH PLASTIC ASIAN SAND WILSONART 7952K-18 SUPPLIED BY TENANT INSTALL BY TENANT G.C. TRIM TYPE T1 LAMINATE IF STORE HAS A FITTING ROOM SEE PLAN PL3 OFFICE DESK AND SUPPORTS LP,gMIINATE NATURAL ALMOND WILSONART D30-60 PROVIDED BY TENANT INSTALLED BY G.C. I— W 1111 r aj CORNER GUARDS O? LOCATION TYPE STYLE/DESCRIPTION MFG. MFG. / REMARKS a) wr RETAIL SALES AREA OUTSIDE CORNERS VINYL 2" X 2" X 8' SURFACE MOUNT, WALLGUARD 2305 SUPPLIED AND INSTALLED BY G.C. INSTALL ON OUTSIDE CORNERS " Q WHITE VINYL CORNER GUARDS. SEE ELEV.FOR LOCATION.ORDER FROM WWW.WALLGUARD.COM ,L ALL NON SALES AREA OUTSIDE CORNERS METAL 2" X 2" X 8' STAINLESS STEEL WALLGUARD 1 2330.1 SUPPLIED AND INSTALLED BY G.C. INSTALL ON ALL OUTSIDE 0 CORNER GUARDS NON SALES AREA CORNERS. FROM FLOOR TO 8' O co —IFinish-Sch.-As-Is-REV-02 CL C LL 2j _j 0) � LLLL LQL N U cd CITY APPROVED PLANS U rn Reviewed for Code Compliance PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS GENERAL: SEE MILLWORKERS SHOP DRAWING FOR tn COMPLETE INSTALLATION INSTRUCTIONS. Cd 1.) RUNNING TRIM BAND 95" 7' L. M LENGTHS ENDS ARE 3 W I MACHINED FOR BISCUITS WALL L INSTALL BISCUITS WITH DOOR AND DOOR WOOD GLUE JAMB CORNER GUARD FRP SEQUENTIA / 2.) SECURE TO EACH WALL CAP. M.CP1130 V O STUD WITH #8 SCREW, MOLDING COUNTER SINK AND MI COVER WITH SUPPLIED in ALUMINUM = c MATCHING SELF - TH ERESHOLD FRP1 v ADHESIVE DISCS M� O SET IN MASTIC FC2 B2 WAINSCOT 4 4 STORE NUMBER B.O. TRIM EXTERIOR MICA VINYL d d 1369 8'-2" A.F.F. i PLAMASIA TRIM "PL2" - - ASIAN SAND SUPPLIED BY TE A T MILLSHOP If ISSUE 'A'-ISSUE:PRELIMINARY DATE: 4/26/22 9 "n'TRIM BAND DETAIL 8 TRANSITION DETAIL 7 CORNER GUARD DETAIL DATE: 6 TOP FRP DETAIL B'-ISSUE LL REVIEW/ BID SET 5/6/22 'C'-ISSUE:PERMIT SET DATE: 6/14/22 'D'-ISSUE: 1" INSULATED DATE: GLAZING 'E'-ISSUE: DATE: 2"x4 1/2" ALUM. 'F'-ISSUE: DOOR JAMB DATE: (FRP1)WAINSCOT (FRP1)WAINSCOT FRP SEQUENTIA (WHERE APPLICABLE) SHEET TITLE CAP. M.CP1130 DOORORAIL MOLDING FINISH PLAN FRP SEQUENTIA Fc3 CAP. M.CP1130 VINYL VI„ NYL ALUMINUM DETAILS AND MOLDING PT2 THRESHOLD SET IN 1/2" X 4" FULL MASTIC SCHEDULE FC3 B2 FFCTJ FC2 WOOD BASE FC1 SCALE FC2 FC1 , L__j L L PT2 VI� EXTERMICO WALK TOR CONC FC2 VINYL VINYL c 1/2' x 3/4" KXIX>o AS N011=D BASE SHOE SHEET NUMBER s TOILET ROOM BASE DETAIL 4 NON-SALES BASE DETAIL s TRANSITION DETAILySALES BASE DETAIL 1 TRANSITION DETAIL A1.2b Page 1 O ROOM AREA O O 101 5' DATE: WALL STANDARDS JJOBNO: 2Z NAM r 010 ROOM LOCATION DESCRIPTION OTY REMARKS G.C. TO SUPPLY ALL DRAWN: STAFF PERIMETER WALL 7'-5' SURFACE MOUNT O — — — — — — — — — — — — — HILTI TOGGLERS HANG ROD BRACKET 104 MOUNTING HARDWARE 0 EACH HOLE OF SALES AREA STANDARD w WHITE FINISH CHECKED: CM STANDARD FIRST HANG ROD TO START PERIMETER WALL 10' SURFACE MOUNT 10 G.C. TO SUPPLY ALL Q 27• 0" Q AT HIGHEST POSSIBLE STOCK AREA STANDARD w/ ZINC FINISH PLUS-6 MOUNTING HARDWARE POINT, MAINTAIN MIN. 18" (19) 7'-5"L SURFACE TD. STDS ® 18" O.C. Et] I � BELOW CEILING OR BREAK AREA SPRINKLER HEAD STOCK 6' SURFACE MOUNT 4 G.C. TO SUPPLY ALL / (TYP.) STANDARD w/ ZINC FINISH MOUNTING HARDWARE ROOM AREA / MANAGER DESK 107 100 S.F f NAM 7' -6" 4' SURFAE MOUNT G.C. DISPLAY HANG RODS TO BE OFFICE STANDA DC w/ ZINC FINISH 4 TO SUPPLY ALL MOUNTING HARDWARE (6) 7'-5"L SURFACE SPACED SO (7) SLOTS IN C O R T L A N O MTD. STDS 0 18" O.0 u ci STANDARD ARE VISIBLE M 0 R G A N 6 BETWEEN BRACKETS RECTANGULAR HANG ROD HARDWARE FOR NON-SALES AREA STANDARDS ARCHITECT 0 ;o ® I. IN 6' LENGTHS, CUT TO ¢ ¢ LL _ LL 711 N. FIELDER RD. in v, FIT, USE SPLICERS AS JJ ROOM AREA e " I o REQUIRED. HANG ROD MAY IZ O > O Q ARLINGTON, TX 76012 NOT EXTEND PAST LAST a j oo r(� oo ~W PH: (817) 635-5696 NAME ® c 6'-10' STANDARDS STANDARD. Z Q To Z Q 2 �� FAX: (817) 635-5699 OFFICE I a o l 00 ® 36" O.C. I \ z DESCRIPTION STOCK AREA \" 1 END CAP FOR RECT TBG w/1" EXT EC4E 7 F 4 14 DETAL*STOCKROOM HANG RODS 12" HVY DUTY BRACKET/RECT TUBING BHR4-12HD 7 14 98 AR CHITEC LICENSED T / SPLICER FOR RECT. TUBING 00678-10020 7 6 42 AR-2098 O —— +1 — — — ® — — — — — — � 6' DISPLAY HANG RAIL HR4-6 7 7 49 DESCRIPTION OFFICE/RECEMNG AREA 12" SHELF KNIFE BRACKET GSBL12 16 C09TLAND MOHGAN © STATF Of IDAHO 6 M LCP J, WALL STANDARDS /SHELVING INSTALLATION NOTES M A A tO$ PROJECT COORDINATION 105 SF LP, SALES AREA 100 5. NAM `z �1 INSTALL PROVIDED 7'-5" LONG SURFACE MOUNTED STANDARDS AS C�,DDTECI-I STOCKROOM I Q a io I INDICATED IN THE PLAN. PROVIDE HILTI TOGGLERS #2158771, TTB - ALL SCREW HEADS ARE TO BE SPRAY PAINTED WHITE TO MATCH THE 215 OAKUHD ROAD,SNa 105 TEL(N( 793-5070 ® I WALL STANDARDS. SOM wINDSOK CT 06074 FAX:( )793-56N - NOTE" STANDARDS TO BE A MINIMUM OF 9" OUT OF A CORNER OR ae.,s N ROOM AREA �� AWAY FROM MILLWORK 100 35 S.F. •. s. D o NAME FITTING ROOM:101 D ao SALES AREA III NO SHELVING. u"I r r�^ ae.,s is < X:7 C) VJ 4 HALL:102 ae.,s D O ® a N I �3 NO SHELVING. w F— M (V R" � z J TOILET ROOM:103,104 Fj) 00 � � I I 'i I I I I I aR.,s D in ® NO SHELVING. W Q © D. . D OFFICE:105 Y vmi Efl INSTALL 4' LONG SURFACE MOUNTED STANDARDS AND PLASTIC ^Q^ COC LAMINATE SHELVING OVER MANAGERS DESK AS SHOWN IN ELEVATION. (L L o SEE SHEET A3.5 Z J J STOCKROOM:106 J Q © G INSTALL 6 and 10 LONG SURFACE MOUNTED STANDARDS AND ALL REQUIRED O W I asxs HANGBARS AND ACCESSORIES AND INDICATED. SEE FIXTURE PLAN SHEET A1.4 � Z U I� AND STOCKROOM ELEVATIONS SHEET A3.4 (� 1 SEE DETAIL "1/A1.3" FOR HANG BAR INSTALLATION. Q 'Q^ o TYP.) U VJ 01 �7 T.G.C. TO INSTALL NEW MOBILE SHELVING / STORAGE SYSTEM AS SHOWN. SEE MFG'S INFORMATION MANUAL FOR COMPLETE INSTALLATION DETAILS. GENERAL ~m ASSEMBLY INFORMATION SEE SHEETS A6.1 - A6.3. OI ® T.G.C. TO INSTALL FIXED TENSCO SHELVING / STORAGE SYSTEM AS SHOWN. SEE ©v:l o MFG'S INFORMATION MANUAL FOR COMPLETE INSTALLATION DETAILS. GENERAL �� ZO ASSEMBLY INFORMATION SEE SHEET A6.4 F I �Q DISPLAY WINDOWS:107,108 C Al O �9 NO SHELVING. � �y =1 Ewn GENERAL NOTE: of - o -- ❑q THE GENERAL CONTRACTOR WILL BE REQUIRED TO FOLLOW THE FIXTURE 0 !A —— I PLAN FOR INSTALLATION OF THE VARYING BACK OF HOUSE SHELVING TYPES. /\ M (I.E., LETTERING DESIGNATIONS A-G), IN ADDITION TO FOLLOWING THE FINAL LJ O FIXTURE PLAN FOR SETTING FIXTURE ON THE SALES FLOOR. STORE O 1� ® — J OPERATIONS WILL ALSO SEND A COPY OF THE FINAL FIXTURE PLAN WITH F V i SHELVING LETTER DESIGNATIONS TO THE STORE MANAGER SO THAT ALL PARTIES ARE IN RECEIPT OF SAME INFORMATION. / 0 STORE NUMBER ro -- 1 1369 M A AINANE \ 108 100 SF. N o ISSUE DISPLAY I o ,A, ATE: PRELIMINARY 4 ? 'B'-ISSUE:LL REVIEW/ BID SET DATE: 5/6/22 'Cl-ISSUE:PERMIT SET NAMTOLET ROOM i -o �n o DATE: 6/14/22 n v+ 'D'-ISSUE: m o DATE: v� 'E'-ISSUE: 7'-6" DATE: 103 75 SF. __ --- (6) 7'-5% SURFACE 'F'-ISSUE: NAME MTD. STDS ® 18" DATE: TOUT RQOL1 SHEET TITLE (3) 7'-5"L (TYP.) 0 SURFACE MTD. CITY APPROVED PLANS WALL STANDARDS sros 01e" D.C. � ————————————— Reviewed for Code Compliance INSTALLATION PLAN PLANS MUST BE ON JOB SITE SCALE -- -- -- -------------- 1/4" = 1'-0' R02 162 SP / 4'-6" r—o#" ,•—o;" 6•_0" " J——————————————J FOR ALL INSPECTIONS NAME SHEET NUMBER (4) 7'-5"L (5) 7'-5"L HALL SURFACE MTD. SURFACE MTD. STDS 0 18" O.C. STDS 0 18" O.C. A1.3 WALL STANDARDS INSTALLATION PLAN JIL PLAN SCALE01/4'-T-7 NORTH Page 1 5 DATE: 4/26/22 LEASE DIMENSION 2 ROOM AREA 1 ROOM AREA JOB N0: 22-010 O 101 57 S.F. 4.2 2O 100 735 sF. 1 RETAIL SHELVING- CARTERS I OSHKOSH Co-Brand 4K DRAWN: STAFF NAME NAME RTTN(`ROgA AREA SHEVING SECTIONS DESIGN GOAL DESIGN ACTUAL REMARKS CHECKED: CM O — — — -- — — — — — — — — — — — — — — — — — 36" SECTIONS 60 46 54" SECTIONS 4=6 +.5 SHELVES o i AREA BREAK DOWN V I / AREA MAN FLOOR SO.FT. 22 \IIII I / 100 SALES AREA 3735 78% C 0 R T L A N D ROOM AREA HI —J I '� 107 100 S.F. 3'-0" 1-0 a-N a- d a-Nj a-NH 101 FITTING ROOM 57 1% N D R G A N NAME / y MIN. L —— 102 HALL 162 3% DISPLAY I I�I I I A R C H I T E C T u CO ? 103 TOILET ROOM 67 1% I y 7n I. TOILET ROOM 70 1% R : T FIELDER RD. y "7 m LL 105 OFFICE 60 1% ARLINGTON, TX 76012 LL LL 106 STOCKROOM 561 11% PH: (817) 635-5696 107 DISPLAY WINDOW 1 100 2% ( ) Ip FAX: 817 635-5699 105 803F. I T LL LL �' 108 DISPLAY WINDOW 1 100 2% NAME 10Z TOTAL: 4912 S0. FT. 100% OF�HCE ARCH, ECT 2 i� CARTERS I OSHKOSH Co-Brand AR-209B m m m i-H 4K FORMAT-4500 SF.-3600 SALES /900 SF BOH y MARK TYPE DESCRIPTION DESIL N DESIACTGN REMARKS L eey m ® m LL F-1 MILLWORK CASHWRAP/BACKWRAP 1 1 C09TLANB MDRGAN I� LL LL STATF Of IDAHO o rg, FN-1 MILLWORK CROSSBOW 4 4 L17 J !e' FIN-2 MILLWORK PILL 2 1 4 ❑ FN-$ MILLWORK MR. T 11 10 AW 13 FN-4 MILLWORK MPT 10 10 PROJECT COORDINATION LCP 8-Nd 8-N� I FN-5 MILLWORK BUNKO 4 4 10 ROOM AREA 20 o Z S-Nj 8-N� E 7-Nj �`1� FN-6 MILLWORK TIC TAC TOE 2 2 CADDTuri III 106 5'81 S.F. LP1 15 I M I FN-7 MIN WDSOIL Cr Deme FAe: 783-seen NAME n MILLWORK M-PLAT 0 0 225 OM'MD MAD.su¢105 M(eA0 ms-sem STOCKROOM 16 TTB 21 I FN-3 MILLWORK WALLY JR.FN-8 MILLWORK WALLY JR. DOUBLES 17 26 a Nj a N� E-149 FN-9 MILLWORK PLAY TABLE 1 0 L 4axis FN-10 MILLWORK ROUNDER 2 3 W T LL D of m III C� I FN-11 MILLWORK HALF ROUNDER 2 2 W '^ as 11 in O V J ,rl p LL „ Z�� ,L;["' I FN-12 MILLWORK WALLY ROLLING FIXTURE 0 0 V, (')Wco4axu D yFlo R.J-1,q MILLWORK WINDOW CUBES 6 6 '^ D 18 7AA ' I FN-15 MILLWORK SHOE CHAIR 4 2 004a�.isD FN-16 MILLWORK TREASURE BOX 2 2 WFN-T7 MILLWORK IPAD BARt4aasD Q O u48-.1. + - - - - - iJ FIXTURE PLAN NOTES: (TENANT G.C.WORK) (L M J 0 W g SALES AREA 100 Z J a 3•_0^ !�zg 6-Nd 3'-O" A A 3'-0" z 3'-0" 3'-0" y ` ❑1 G.C. TO INSTALL PROVIDED SURFACE MOUNTED STANDARDS, PROVIDE HITLI TOGGLERS O LL A� m o MIN. MIN. 9-NH 8-NU MIN. c MIN. MIN. FOR EACH SALES AREA STANDARD, COORDINATE WITH STORE MANAGER FOR W W INSTALLATION OF ALL PERIMETER HARDWARE AND SHELVES. SEE STANDARDS Z U w e.1s- E h INSTALLATION PLAN SHEET A1.3 ZCd ❑2 ASSEMBLE AND INSTALL ALL TENANT SUPPLIED FLOOR FIXTURES, THE MINIMUM WIDTH Q Q 4e.1s G of 3 OF DISPLAY AISLES SHALL BE NOT LESS THAN 36" WIDE 00 M I I 3 1 I I Ur cn G.C. TO INSTALL CASHDESK AS DIMENSIONED. HANDICAP CHECK OUT COUNTERS SHALL I I I I BE PROVIDED AT A SECTION OF THE COUNTER HAT IS AT LEAST 36" LONG AND NO FN-a FN-8 FN-8 MORE THAN 34" HIGH FOR BOTH EMPLOYEES AND CUSTOMERS. r r r ® FIRE EXTINGUISHER SHALL BE 10 L.B. MULTIPURPOSE DRY CHEMICAL(CLASS A,B,C,) RATED NOT LESS THAN 2A-10BC MOUNTED 36" A.F.F. MAX. TRAVEL DISTANCE SHALL \� t 9 m s, s. I Z I z m [Ell '� H NOT BE MORE THAN 75 FEET PER NFPA 10 � � I w o M LL ' y y FITTING ROOM: N a w c ❑5 G.C. TO INSTALL SUPPLIED INTERIOR FINISHES, ASSOCIATED TRIM, FITTING ROOM (d O it BENCHES, MIRRORS AND ACCESSORIES. SEE FITTING ROOM ELEVATIONS SHEET A3.6 r FN-8 FN-8 FN-8 L Fm —a r Y Y Y £N� I HALL:102 m © EXISTING DRINKING FOUNTAIN TO REMAIN. O I 11 _I a M LL , �iy I TOILET ROOMW-103/104 V O 1 ❑7 EXISTING TOILET ROOMS TO REMAIN, G.C. TO INSTALL ALL TENANT SUPPLIED FIXTURES F AND ACCESSORIES WITH-IN TOILET ROOMS AS NOTED, COORDINATE WITH FIXTURE O —-A—— LL ' SCHEDULE AND ELEVATIONS. SEE SHEET A3.3 D I r FN-8 FN-8 — — J STORE NUMBER L__—J ® ® EXISTING MOP SINK TO REMAIN. OFFICE:105 1369 / IIII M L J� ❑9 G.C. TO INSTALL TENANT PROVIDED OFFICE COUNTERS, INSTALL WALL STANDARDS AND —_ ——— SHELVES. SEE OFFICE DETAILS SHEET A3.5 zz I — —6P ---- LL „ LL ' LL ' STOCKROOM 106 ISSUE ROOM AR A \ m FN-8 FN-8 'A'-ISSUE:PRELIMINARY ,� I� DATE: 4/26/22 108 100 Sp. f0 G.C. TO INSTALL ALL PROVIDED STOCKROOM WALL STANDARDS AND BRACKETS. AM LL „ LL „ LL • ��. PROVIDE HITLI TOGGLERS FOR EACH 10'-0" STOCK AREA STANDARDS. SEE STANDARDS 'B'-ISSUE:LL REVIEW / BID SET DISPLAY I� INSTALLATION PLAN SHEET A1.3 AND STOCKROOM ELEVATIONS SHEET A3.4 DATE: 5/6/22 om m I LL „ LL ' gg 11 G.C. TO INSTALL PROVIDED HANGER MANAGEMENT UNIT. -ISSUE:PERMIT SET 7 I in LEI DATE: 6/14/22 1OgM m r r 12 G.C. TO INSTALL PROVIDED HARDWARE BIN. 'D'-ISSUE: NAME 3,_0 FN-8 FN-6 LL DATE: $ LL' TOILET ROOM 13 G.C. TO INSTALL SUPPLIED BREAK TABLE AND WALL MOUNTED CORK BOARD. T-ISSUE: DATE: 3 G.C. TO INSTALL MICROWAVE, REFRIG. AND WALL MOUNTED CLOCK. 1 F'-ISSUE: 7 91P 8 m DATE: ARE 1 1 LL > I� I 15 G.C. TO INSTALL LOCKERS, ATTACH TO WALL USING HITTI TOGGLER SYSTEM. 103 75 SF. _FD77. of ? I I I� 16 G.C. TO INSTALL TENANT PROVIDED EMPLOYEE COAT HOOK. SHEET TITLE NAME —L_— M 1 1 m ❑ 16M ROOM I u I} 17 G.C. TO INSTALL TENANT PROVIDED WALL MOUNTED NETWORK CABINET 8'-0" A.F.F.. FLOOR FIXTURING/ ❑18 G.C. TO INSTALL MOBILE SHELVING SYSTEM. SEE SHEET A6.1-A6.3 MILLWORK PLAN G.C. TO INSTALL TESNCO SHELVING SYSTEM. SEE SHEET A6.4 CITY APPROVED PLANS ❑ SCALE 20 LOCATION EXISTING ELECTRICAL SERVICE PANELS, NEW LIGHTING CONTROL PANEL ETC. 1IT 1 Reviewed for Code Compliance SEE ELECTRICAL DRAWINGS. 1/A' = '—On LOCATION FOR EXISTING TELEPHONE BOARD AND SECURITY 1 �F i 1 -- — -- -- -------------- PLANS MUST BE ON JOB SITE SHEET NUMBER A 6 / _ DISPLAY WINDOWS 107/108 ROOM ARE ����� ————————— ————— 102 1625'F' L 1 FIXTURE PLAN FOR ALL INSPECTIONS 22 NO FIXTURING REQUIRED A1.4 NAME / 1 PLAN HALL •1 SCALE:1/4'-T-0' NORTH Page 1 3,4 1 s 3 8 10 11 LIGHT FIXTURE SCHEDULE: DATE: 4/26/22 M M SYM MARK DESCRIPTION MFG CATALOG LAMP TYPE VOLTAGE MOUNTING TY REMARKS 10'-0" JOB NO: 22-010 101 CL2 100 CL1 RECESSED 2X4 ARCHITECTURAL ENC O HEIGHT MISC. O HEIGHT MISC. (2)SECTIONS OF WIRE GRID O LINEAR LED FIXTURE UT EMERGENCY ATTAIN CART-AT-TF-24-50- 50 WATT/LED UNIV RECESSED 4 PROVIDED BY TENANT DRAWN: STAFF 8'-0' ACT DECK HP FOR POSTER DISPLAY o' A/EM 37-A-EM STOOK INSTALLED BY G.C. 15'-10" VARIES OPEN ,-' BALLAST AND 90 MINUTE BATTERY ------------ r , BACK-UP CHECKED: CM 5 __ 4 LED PENDANT FIXTURE SUSPENDED COLOR J-BOX TENANT ® AA SPECTRUM DB1817LEDGVSSl.35KE%/ 40.6 WATT/LED PROVIDED MATTE WHITE 120V MOUNT 43 INSTALLED BY G.C. B.O. LIGHTING RDCS/HMAT60/XX/XX 3500K PENDANT FIXTURE MOUNT 10'-6" A.F.F. FIXTURE PROVIDED WITH 60" STEMS TO BE B o _ - FIELD CUT in *q�M TRACK MOUNTED LED WALL WASHER, (56) HEADS PROVIDED BY TENANT 11L\ 0 WINI Im——— �FR FR 7Im FR FR gVµ+ TT CON-TECH CTL181 V35D-R 3p WATT/LED TRACK \\\\� — — -- 'L31 B�/X' MOUNTED IN SINGLE CIRCUIT TRACK, 120V (1) 49' TRK INSTALLED BY G.C. MOUNT COLOR WHITE.SUSPENDED FROM (1) 28' TRK G.C. TO PROVIDE O BV28+ LE STRUCTURE (1) 20' TRK UNISTRUT AND ® AA AA AA A TRACK FROM STRUCTURE. �- (1) 15' TRK C O R T L A N D 2 14' TRK M 0 R G A N - - - 7 - - 9 o - a-- - ( ) SET TRACK O 10'-6" I� (3) 10' TRK A.F.F. A R C H I T E C T (TYP.) �n (1) 5' TRK 25 -27 _ _ _ _ _ _ - _ IE o OM TYPE I 4 6VLFX400035KD8- CL2 5'-0" - BUS = i�y ® (; 6" LED DOWNLIGHT PATHWAY 6VLEDMD 36 WATT/LED UNIV RECESSED 12 PROVIDED BY TENANT 711 N. FIELDER RD. 105 HEIGHT MISC. _ (TYP.) - _ o - - PH m g INSTALLED BY G.C. ARLINGTON, TX 76012 10'-0' ACT , 3 PH: (817) 635-5696 C F 4' LED STRIP LIGHT FIXTURE ATTAIN AT-PD-4-30-35-B-WH-N 30W/LED UNIV SUSPENDED 5 PROVIDED BY TENANT FAX: (817) 635-5699 in w INSTALLED BY G.C. O - - - - - - - O"- 5 - c o LED EDGE-LIT EXIT SIGN BEST 1 a ELXTEY-I-R-C-A INCLUDED UNIV CEILING 3 PROVIDED BY TENANT 32 33 34 YPE I 0 AA AA AA W o ® X WITH 90 MIN BATTERY BACK-UP LIGHTING INSTALLED BY G.C. LICENSED INOOM 107 CL3 ® AA (TYP.) HH M" DOUBLE HEAD EMERGENCY PROVIDED BY TENANT 11 ARCHITECT HEIGHT MISC. C �� Y WITH 90 MIN BATTERY BACK-UP PATHWAY AR-2-DL INCLUDED 120V SUSPENDED 8 INSTALLED BY G.C. AR-2096ifBD. EXISTING DOUBLE HEAD EMERGENCY EXISTING FIXTURE CLEAN3'-4" 9'-0" 9'-0" 9'-0" 9'-0" V.I.F. V.I.F. INCLUDED 120 SURFACE 2 WITH 90 MIN BATTERY BACK-UP AND TEST I I EXISTING STANDARD LED EXIT SIGN EXISTING FIXTURE CLEAN © -L- ® -I CM WITH 90 MIN BATTERY BACK-UP V.I.F. V.I.F. INCLUDED 120 SURFACE 2 AND TEST CORTLAND ORGAN ' AA ® STATE Or IDAHO ® 8 AUDIO SPEAKERS ---- ---- ---- ---- RECESSED 6 SUPPLIED, INSTALLED BY TENANT VENDOR REFLD-CLG-LGT-AS-IS-REV-00 PROJECT COORDINATION AA AA AA AA I DECK HGT ❑ 215 OAKUND ROAD.SURE 105 TM.(ND)]83-Ni70 -0 _ _ TYP.)- -CEILING TYPES: MISC. CEILING LEGEND: SOUTH WNDSOR,Cr OW4 FAX:(A60)785-5610 v Y 2 EXISTING OPEN TO STRUCTURE CEILING, PAINTED REFRESH (PT1) L- 13 I SUPPLY AIR REGISTER, SEE MECHANICAL DRAWINGS �r IXn, '0L2 2' X 4' SUSPENDED ACOUSTICAL CEILING:fflym ... L" USG DONN 15/16", 2 X 4 TEE GRID, COLOR WHITE W r L'^ REPLACE ACOUSTICAL TILES: 2 X 4 X 3/4" USG "MARS CLIMA PLUS" (SQ) ( VJ #88185, COLOR WHITE. SEE SUSPENDED CEILING DETAIL 4/A5.2 � ('7 � RETURN AIR REGISTER. SEE MECHANICAL DRAWINGS W ROOM � � r 281291301311M TYPE I AA AA AA ' (.�.9 EXISTING GYP. BD. CEILING PATCH AND REPAIR AND REPAINT (PT1). �j - - MISC�.4 a AA - ® 11 11 - —0 Q - O EIGHT 1S-T OPEN - - - - (TYP ( - �❑1 CLA EXISTING OPEN TO STRUCTURE CEILING UNFINISHED. O r^ F 12 C J O J J C — — — — — — — — — — J ET _ _ _ _ _ _ _ EILING PLAN NOTES Z J a 1` (TYP.) o -`GIA'z._6+• O Ff L W oEfl STOREFRONT- HALL:102 U I - - - - - - - - ., ❑1 NEW EXTERIOR CARTERS SIGNS FRONT AND REAR OF BUILDING, BY TENANT Z Cd SIGN CONTRACTOR UNDER SEPARATE PERMIT. SEE ELECTRICAL DRAWINGS FOR 16 EXISTING OPEN TO STRUCTURE CEILING UN-FINISHED. ®AA AA POWER REQUIREMENTS. Q r� FRL G.C. TO INSTALL PROVIDED LED STRIP LIGHT FIXTURES "F" AND "F/NL" U � vJ ® ® ❑2 G.C. TO PROVIDE AND INSTALL A DUPLEX RECEPTACLE ABOVE SHOW WINDOW AS SHOWN, REPLACING EXISTING ONE FOR ONE. INTERIOR FOR OSHKOSH SIGN 18 EXISTING EXIT LIGHT FIXTURES "EX/X" TO REMAIN, CLEAN TEST, REPAIR. - SALES FLOOR:100 19 EXISTING EMERGENCY LIGHT FIXTURES "EX/Y" TO REMAIN, CLEAN TEST, ❑3 RETAIL AREA EXISTING CEILING OPEN TO STRUCTURE WITH PAINTED ROOF DECK, REPAIR. WOOD JOISTS, CONDUITS, AND DUCT WORK CLEAN AND HIGH BAY DUST ALL I o I 20 EXISTING HVAC DUCT WORK TO REMAIN. CLEAN. 9 AREAS, REPAINT (PT- L !wl (Typ,) ® 1) WITH DRY-FALL. ®AA INSTALL "B1" LED TRACK LIGHT FIXTURES AT STOREFRONT DISPLAY TOILET ROOM:103/104 C < WINDOWS. LOCATE O 10'-6" A.F.F. SUSPENDED WITH ALL THREAD AND cd WY I 10 UNISTRUT. 21 EXISTING 2 X 4 ACOUSTICAL CEILING TO REMAIN. REPLACE CEILING TILES L _ _ I _ _ _ _ F Iy� I 5 G.C. TO INSTALL PROVIDED STOREFRONT WIRE GRID POSTER TRACK SYSTEM. I ❑ 22 G.C. TO INSTALL PROVIDED 2 X 4 LED LIGHT FIXTURES "A/EM" AS I AA f�A�A� I I I SUSPEND FROM JOISTS ABOVE. SEE INSTALLATION DETAIL. SHOWN. O AA AA �M' - ❑8 G.C. 23 EXISTING TOILET EXHAUST TO REMAIN, CLEAN AS REQUIRED. A "AA" AS SHOWN.INSTALL PROVIDED PENDANT SUSPENDED HIGH BAY LED FIXTURES /\ v• - - - - - - - 6 V O I G.C. TO PROVIDE ALL UNISTRUT AND ALL THREAD TO F(Tsc)- LOCATE FIXTURES AS DIMENSIONED. WHERE REQUIRED AT DUCT WORK 24 EXISTING HVAC DIFFUSERS TO REMAIN. CLEAN U STRADDLE UNISTRUT BELOW DUCT WORK AND OR OTHER OBSTRUCTIONS. - LOCATE FOR B.O. FIXTURE O 10'-6" A.F.F., SEE DETAIL 6/A5.2 O OFFICE AREA 105 D - _ - f _ _ _ _ = _ _ _ _ J 7 STORE NUMBER ® ❑ G.C. TO INSTALL ACCENT TRACK LIGHTING FIXTURES TYPE "B1" ALONG I THE PERIMETER B.O. "TRACK" AT 10'-6" A.F.F., PROVIDE AND INSTALL G.C. TO PROVIDE AND INSTALL 2 X 4 ACOUSTICAL CEILING SYSTEM (CL1) - - - - AA UNISTRUT AND ALL THREAD AS REQUIRED TO LOCATION TRACK. SEE DETAIL G. SHOWN. ���WX 5'-0" 7/A5.2 26 SHOWN. INSTALL PROVIDED 2 X 4 LED LIGHT FIXTURES TYPE "A" AS 32 33 34 - - - - - ®G.C. TO INSTALL PROVIDED EXIT LIGHT FIXTURES E r ff� 27 G.C. TO INSTALL HVAC DIFFUSERS PER MECHANICAL ISSUE 108 CL3 I AA :,_ AA AA I�Buµ 'A'-ISSUE:PRELIMINARY 7 MISC. — ® — — — — — 9❑G.C. TO INSTALL PROVIDED EMERGENCY LIGHT FIXTURES LIGHT FIXTURES "Y". STOCKROOM:106 DATE: 4/26/22 iF-0' YP.BD. I� SURFACE MOUNTED TO WOOD JOISTS 28 AREA IS OPEN TO STRUCTURE UNFINISHED. 'B'-ISSUE:ILL REVIEW / BID SET I 4 DATE: 5/6/22 10 MUSIC SYSTEM SPEAKERS AND WIRE PROVIDED AND INSTALLED BY C® 5'-0" I� TENANT VENDOR. ALL SPEAKERS ARE MOUNTED TO THE WOOD JOISTS 29 G.C. TO INSTALL PROVIDED LED STRIP LIGHT FIXTURES "F" AND "F/NL" 'C'-ISSUE:PERMIT SET 2122 23 24 ' > OR STRUCTURE. SPEAKERS SHALL NOT BE PENDANT SUSPENDED. G.C. AS SHOWN, REPLACING ONE FOR ONE WITH EXISTING. DATE: 6/14/22 CL2 - F - - - o - - _ i SHALL INSTALL POWER AND J-BOX FOR SPEAKER WIRE BACK AT THE HEIGHT MISC. �O, o 4 o 3 o MANGERS OFFICE ONLY. 30 EXISTING EXIT LIGHT FIXTURES "EX/X" TO REMAIN, CLEAN TEST, REPAIR. 'D'-ISSUE: 8-0' ACT. DATE: 11 EXISTING HVAC DUCT WORK TO REMAIN. CLEAN AND REPAINT (PT-1). 31 EXISTING EMERGENCY LIGHT FIXTURES "EX/Y" TO REMAIN, CLEAN TEST, 'E'-ISSUE: ®® -H n a a REPAIR. DATE: _ _ _ _ _ _ _ I�- W 12 'F'-ISSUE: ELECTRICAL DRAWINGS. G.C. TO PROVIDE UNISTRUT ATTACHED TO C LOCATION FOR ITECH RETAIL AREA SECURITY MONITORS. SEE DISPLAY WINDOWS�107/108 STRUCTURE ABOVE FOR MONITOR MOUNTING BY VENDOR AA AA (TYPO AA _ AA I� ,� 32 EXISTING GYP. BD. CEILINGS TO REMAIN. PATCH REPAIR AND PAINT (PT-1) DATE: IFI� ❑I 13 EXISTING AIR CURTAIN TO REMAIN. CLEAN, TEST, REPAIR FOR LIKE SHEET TITLE 121122123124 �n NEW OPERATION. 33 G.C. TO INSTALL PROVIDED TRACK MOUNTED "B7" LED LIGHT FIXTURES. ROOM TYPO O BI/W f- FITTING ROOM:101 34 G.C. TO INSTALL PROVIDED RECESSED LIGHTING TYPE "C". REPLACING EXISTING REFLECTED HEIGHT MISC. ��"{'�� ONE FOR ONE. ✓EILING PLAN 8'-0' ACT. ' FR FR FR FR FFFR FR FR FR F7w1 13 G.C. TO PROVIDE AND INSTALL 2 X 4 ACOUSTICAL CEILING. L - - - I - - 41 -- - J CITY APPROVED PLANS C 19 I 14 G.C. TO INSTALL PROVIDED 2 X 4 LED LIGHT FIXTURES "A/EM" AS SHOWN. SCALE Reviewed for Code Compliance 1�4" f7fl15 G.C. TO INSTALL HVAC DIFFUSERS PER MECHANICAL 1008.3.3 Rooms and spaces:In the event of power supply O - failure,an emergency electrical system shall automatically PLANS MUST BE ON JOB SITE SHEET NUMBER 16 17 18 19 20 5 4 FEmergency : illuminate all the following areas: ROOM L --- J y power sh7providedd for 1.Electricalequipmentrooms. FOR ALL INSPECTIONS p ^.� 102 0" 10-o'r s re uired HL/�� q 2.Fire command centers. REFLECTED CEILING PLAN / \PLAN (2)SECTIONS OF WIRE GRID he systemable 3.Fire pump rooms.15-V OPEN SCALE:1/4'-f-0' NORTH FOR POSTER DISPLAY g the requi 4.Generator rooms. not less ths. Pagel Buildings shall have approved address numbers,or approved building - • Zoning Identification placed Knox Box Installation DRAWN: STAFF All buildings shall have a permanently posted address,which shall be placed A Knox Box shall be installed at each driveway entrance and be visible from both directions of travel along to the right of the main access CHECKED: CM the road.Buildings shall have approved address numbers,or approved door(s).It should be mounted All Signs Require building Identification placed in a position that is plainly legible,visible from between 6 and 7 feet from Separate Permit the street or frontage road fronting the property and of a contrasting color(IFC round level.Alternative CITY APPROVED PLANS 505.1). g Address size is based on distance from the street:up to 50 ft.is 4 in.,51 to locations will have to be 100 ft.is 6 in.,101 to 150 ft.is 8 in.,151 to 200 ft.is 10 in.and greater is 12 in approved by the Fire Marshal. Reviewed for Code Compliance PLANS MUST BE ON JOB SITE C 0 R T L A N D M 0 R 0 A N FOR ALL INSPECTIONS A R C H I T E C T 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 80-01" FAX: (817) 635-5699 EXTENT OF STOREFRONT NEW TENANT SIGN: LICENSED SIGN CONTRACTOR TO PROVIDE SHOP DRAWINGS IN ACCORDANCE ARCHITECT WITH ALL LANDLORD CRITERIA. SUBMIT SHOP DRAWINGS TO THE AR-2098 LANDLORD FOR APPROVAL PRIOR TO FABRICATION. ALL SIGNS TO BE IN ACCORDANCE WITH MALL CRITERIA AND LOCAL REQUIREMENTS AND TO BE INSTALLED UNDER SEPARATE PERMIT. CGRTLANR MGRGAN STATF GF IOAHG O - EXISTING BUILDING PROJECT COORDINATION ro FACADE (ADDTech 225 OAKLAND ROAD,SLIDE IGG TEL(eeo11 M-5Aw SLUM C11GSpl,Cr 06071 FAL(8b0)78i-0fiB0 EXISTING AWNING NEW FABRIC COVER CARTERS BLUE, PMS 2995 I - -_ T.O. ENTRY �' W LL ® 9'-11" A.F.F. \\ W p I W (j 0000 N \ \� W in v� oQOC E= L L VZ J Q ILLUMIO,ryI�AlTED OSHKO HSIGN O (W] LL V CEJ EXISTING,ALUMINUM EXISTING,ALUMINUM EX 3'-0 EXI"I PANEL BEF IND 16 ALUMINUM Z i Z 0 IL EXISTING ALUMINUM �/\l V� rQ FRAMING AND GLASS FRAMING AND GLASS ALUMINUM ENTRY DOORS ALUMINUM FRAMING AND GLASS V VJ FRAMING AND FRAMING AND GLASS GLASS �1 STOREFRONT ELEVATION L SCALE:1/4'-T-0' L HI Cd Q� O I IRO L = STORE NUMBER No 1369 jo Jo 1O aQ I I I � I I" aQ � Zc� � 00 = Z ISSUE N Q L 'A'-ISSUE:PRELIMINARY W E w 4 DATE: 4/26/22 ILLUMINATED OSHKOSH � 'B'-ISSUE:LL REVIEW / BID SET SIGN ON PANEL BEHIND DATE: 5/6T S �mmmmggmmmmmq$qwmmmmFR FRmmmmmgRmmmmmq$RmmmmmR}FI� _�Lt]Lt]LI tH ttm m m m HL m�tH Lt]LH LH tH tH GLASS tiL tlL m t:d t:d tH�tH tH HL m m�m m m m m 'C'-ISSUE:PERMIT SET DATE: 6/14/22 -------------- ------------------- ----- - -------------------- 'D'-ISSUE: n 'E'-ISSUE: .. .. .. .. -------------------- ,. DATE: ---- - - ---- - - - -------------------- -------------------- ------- -------------------- 'F'-ISSUE: NEW STORE RONT DATE: EXTERIOR SIN ABOVE SHEET TITLE 5,_04" 6.-0" 5._o}" 16,-2j„ EXISTING ALUMINUM EXISTING ALUMINUM EXISTING 3'-0" X 7'-0" EXISTING EXISTING ALUMINUM STOREFRONT PLAN FRAMING AND GLASS FRAMING AND GLASS ALUMINUM ENTRY DOORS ALUMINUM FRAMING AND GLASS ELEVATION AND FRAMING AND GLASS GLASS 80-01" U SCALE EXTENT OF STOREFRONT AS NOTED �1 STOREFRONT PLAN SHEET NUMBER 1 SCALE:1/4'-T-0' A3.0 Page 1 Planning i Zoning DRAWN: STAFF CHECKED: CM All Signs Require Separate Permit C 0 R T L A N 0 M 0 R 0 A N ARCHITECT 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 ALICENSED RCHITECT AR-2098 80'-0}" EXTENT OF STOREFRONT NEW TENANT SIGN: SIGN CONTRACTOR TO PROVIDE SHOP DRAWINGS IN ACCORDANCE C09TEARD MORGAN WITH ALL LANDLORD CRITERIA. SUBMIT SHOP DRAWINGS TO THE S7ATF Or IOAHO LANDLORD FOR APPROVAL PRIOR TO FABRICATION. ALL SIGNS TO BE IN ACCORDANCE WITH MALL CRITERIA AND LOCAL REQUIREMENTS AND TO BE INSTALLED UNDER SEPARATE PERMIT. PROJECT COORDINATION (ADDR(ri 215 OAKUND ROAD,SUE 105 TEL(N( 793-5670 EXISTING BUILDING SONH WINDSOR,CT 06074 FAX:(M 1793-5690 FACADE n EXISTING AWNING ,1 1 T LE NEW FABRIC W O U) COVER CARTERSCD cc BLUE, PMS 2995 W � N I ar, T.O. ENTRY a 55 ® 9'-11" A.F.F. W V ELECTRIC 'IY EQUIPMENT J J J Z J Q Oz Z U Urn CL REAR ELEVATION 2 SCALE:1 4V-T-17 F c L HI Q� O o V O STORE NUMBER 1369 ISSUE 'A'—ISSUE:PRELIMINARY L]119,—�, DATE: 4/26/22 EVIEW'B'—ISSUE:LLREVIEW/ BID SET DATE: 5/6/22 r �I 'Cl—ISSUE:PERMIT SET VimIL DATE: 6 14 22 _ I W � � 0 � 0 0 W U' / / j'S 09 ® ® av Q 09 ® ® ' ' ISSUE: ve _ ��------------------� DATE: k 'E'—ISSUE: �4111 ® DATE: -------------------- -------------------- 'F'—ISSUE: DATE: -----_ ---- -- -- — — — SHEET TITLE NEW 16'-3" EXTERIOR RSIGN NAB E j" 16'-2 EXISTING ALUMINUM EXISTING ALUMINUM REAR PLAN FRAMING AND GLASS FRAMING AND GLASS ELEVATION EXTENT OF STOREFRONT CITY APPROVED PLANS SCALE AS NOTED Reviewed for Code Compliance 1 PLANS MUST BE ON JOB SITE SHEET NUMBER REAR PLAN FOR ALL INSPECTIONS SCALE: -T-0' A W Pa e 1 ® EATE: I. Yi aT CITY APPROVED PLANS JOB NO: 2-010 B.O. DECK -- _- ReVieWedfor Code Compliance _ 15'-11" A.F.F. DRAWN: STAFF PLANS MUST BE ON 106 SITE CHECKED: CM TRIM BOARD WALLS TRIM All Signs Require WALLS BOARD FOR ALL INSPECTIONS 1 Prt Separate Permit Pn TT 5 T.O. WALL 0 I• � 10-5 A.F.F. Carter's T.O. STANDARD 61 8'-2" A.F.F. C O R T L A N D_I 1_1 1_1 1_1 N 0 R G A N o ARCHITECT II L II L J ^ 711 N. FIELDER RD. J _ _ _ ARLINGTON, TX 76012--- ---J L--- I I PH: (817) 635-5696 B.O. STND FAX: (817) 635-5699 9 A.F.F. III mot, O � BACK WRAP AREA (p) (I) 61 B1 LICENSED Y '// ARCHITECT AR-2098 �c1 NTERIOR ELEVATION w MERIOR ELEVATION V ecus vr-ro '+ xxnUr wa 1 I B.O. DECK ` B.O. DECK 16'-7" A.F.F. COBTLANO MOHGAN 15'-10" A.F.F. GTATF Or IOAHG - ❑ TRIM BOARD WALLS L 1 PT1 T.O. WALL O TRIM PROJECT COORDINATION -0 A.F.F. WALLS BOARD CADDTu1ri I I I I PT7 T1 III mHII225 GI�"1+OLCr 06074 105 FAA-R((V6 �-s58eeo 7-7 G 0 ?-. I T.0- STANDARD io 8'-2" A.F.F. ro rl -- -- WALLSLL W U) KEY PLAN CA cr co SCALE:N.T.S. L---J L---J L---J B.O. STND W in 53 B1 51 < O co (� J It NTERIOR ELEVATION rj MEFtlOR ELEVATION Z J Q J ecusvr•ro 3 erasvrao O _3 N Z U B. L LL O. DECK Q " Q 15'-10" A.F.F. V Cn TRIM BOARD WALLS T1 PT1 T.O. WALL 0 TRIM GRAPHIC BY 12-0 A.F.F. WALLS BOARD TENANT SIGN I I I I CONTRACTOR � PT1 T1 � Fittin Room o Cd O T.0- STANDARD I MML � r 8'-2" A.F.F. fO� W L I I I U � y I I I I I I B.O. STND STORE NUMBER SIGN OF ACCESSIBILITY B1 B1 BY T.G.C., SEE ADA.1 P 1369 DOOR ANNDD FRAME 6 INTERIOR ELFNATION INTEPoOR ELEVATION flGLLbvr as L BGNL UP HIV ISSUE 'A'-ISSUE:PRELIMINARY DATE: 4/26/22 'B'-ISSUE:LL REVIEW / BID SET B.O. DECK j DATE: 5/6/22 16'-7" A.F.F. ICI-ISSUE:PERMIT SET TRIM .TRIM DATE: 6/14/22 BOARD WALLS TRIM WALLS BOARD 'D'-ISSUE: T1 T1 WALLS BOARD PT1 T1 DATE: T.0- WALL 0 PT1 T1 T.O. PARTTION 'E'-ISSUE: 12-0 A-F.F. WALLS PT1 'F'-ISSUE: I I I I DATE: M SHEET TITLE T.O. STANDARD io 8'-2" A.F.F. SALES AREA Ir -1 IF_ II -% (� ELEVATIONS AND \ KEY PLAN SCALE 1/4" = T-IT B.O. STND SHEET NUMBER BACK OF "OSHKOSH" SIGN t 5 INTERIOR E NTEPoOfi ELEVAl10N A3.2 J BONHvr•ra 1 W Ur-r-0 Pagel- DATE: 4/26/22 / a w 41" w F cwi 1 3fi„ JOB NO: 22-010 SPOUT 13"-18" SPOUT MAXIMUM BOWL O DRAWN: STAFF o g, SURFACE MOUNT T ILET HEIGHTS HEIGHTS DEPTH 6 1/7T�„ I o w v�i PAPER DISP. SHAL PERMIT CHECKED: CM MIN. M=z 'y,., CONTINUOUS PAPE FLOW DP DP DIP ^ z a >r ?>� x HAND OPERATED - [42" 12" _ s WRIST BLADE G.B. r �p / OP STYLE FAUCET w wTOP T 0 z a _ X X Q a 8" a s 1 a a 1 MAXIMUM BOWLI ALL EXPOSED x z 0 1 I - x I DEPTH 6 1 2"I a m a 7• PP (� i. z z / - x PIPING TO BE ®❑ P. F L „� m e a MIN ( LOW FOUNTAIN fO a- a a: 8" INSULATED t` z x W > M ^ z KNEE CLR. M n rn Z. z o� a MIN z M N 3 L M N 3N MIN 15 a20 M ,��� A x C 0 R T L A N D in 0 1 KNEE CL MIN. w A ^ �'Q a ACCESSORY APRON 1 =LL '�a W M 0 R 0 A N 30" 30" " TOILET SEAT A R C H I T E C T MAX 0 CLR. COVER DISPENSER SURFACE DRINKING FOUNTAIN MIN MIN MAX 0 CLR. FLOOR MOUNT WALL MOUNT ACCESSIBLE TOILET PAPER LIGHT SWITCH ACCESSIBLE SOAP MOUNTED ELEV. DRINKING FOUNTAIN DRINKING FOUNTAIN LAVATORY LAVATORY SECTION LAVATORY& MIRROR FLOOR MOUNT WATER CLOSET VERT. GRAB 711 N. FIELDER RD. DUPLEX DISPENSER CONTROLS DISPENSER HAND DRYER PLAN ELEVATION. PLAN ELEV. WATER CLOSET ELEV. BAR p711 N. FIELDER TX 76012 RECEPTACLE ELEV. PH: (817) 635-5696 FAX: (817) 635-5699 ACCESSBLE INSTALLATION DIAGRAMS erxsv�-ro LICENSED NOTES: ARCHITECT ET PT2 PT2 ply 1. MOUNT KOALA CHANGING STATION AR-2o96 AS PER DETAIL. BED HEIGHT TO BE ABY CHANGING B.O. CEILING B.O. CEILING B.O. CEILING B.O. CEILING 31" FROM FLOOR WHEN INSTALLED STATION (UP) 8'-0' A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. WITH THESE DIMENSIONS COAT HOOK USE CLEAR FRP1 MIRROR I FRP1 I FIXTURE O // RP1 SEALANT AT ,I FRP1 CHANGING 4'-0" A.F.F. CHANGING STATION' Tn �i / STATION ON) CORTLANR MORGAN T.O. FRP T.O. FRP T.O. FRP T.O. FRP DASHED LINES INDICATE STEEL STATE Of InAHO 4'-6" A.F.F. 4'-6" A.F.F. / 4'-6" A.F.F. 4'-6" A.F.F. I STUD FRAMING IN WALL GRAB BAR GRAB SURFACE I LAVATORY BARS 'KOALA' BRAND MOUNT HAND o TOILET PAPER PT2 WALL MTD. FOLD 1O DRYER WATER + HOLDER • D QR io DOWN. SEE DETAIL a a MOUNTING HOLES CLOSET & T \ I "A" THIS SHEET I. r _ N PROJECT COORDINATION INSULATE HOT WATER & TOILET SEAT WATER PROVIDE SILICONE CADDTtai DRAIN LINES TO PROTECT CLOSET SEALANT JOINT AT TOP w FC3 COVER FC3 FC3 FC3 I I 0 SOU H WIIANo Rn1A 3074E 145 iFA(8Q1 783-M AGAINST CONTACT. NO OF COVE BASE & SHARP OR ABRASIVE DISPENSER FRP (TYP.) I I I rc BABY CHANGING sanH wlRosoe,Cr Same FA1h( )ms-seen SURFACES UNDER LAV. I I I t^R STATION SECTION �n1TOuavr LET ROOM ELEVATION �TOLET ROOM ELEVATION �TOLET ROOM ELEVATION �TOLET ROOM ELEVATION I I � ec -ro o ecuavr-w / ecunvr-ro v erenw-rc II i Ix PT2 PT2 PT2 PT2 FRP1 W T LE B.O. CEILING B.O. CEILING B.O. CEILING B.O. CEILING �A�BABY OHANGWO TABLE DECAL w 0 8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. A �'�•'� ;p SURFACE ;p OAT HOOK Ap e W r�r^^ � �N- 00 MIRROR-- FRP1 I FRPi MOUNT HAND I pRp \ FIXTURE O I FRP1 ro DRYER ro \ 4'-0" A.F.F.' "I T.O. FRP T.O. FRP \ T.O. FRP T.O. FRP w 0 4'-6" A.F.F. 4'-6" A.F.F. \ 4'-6" A.F.F. GRAB 4'-6" A.F.F. GRAB BAR BARS O CA CO LAVATORY 1O '° '.,,TRIM '° CO a DO TOILET I C J CLOSET PAPER WATER MOP SINK a L / HOLDER Z J J INSULATE HOT WATER & PROVIDE SILICONE WATER TO LL ILET SEAT F1f1 GL DRAIN LINES TO PROTECT FC3 FC3 SEALANT JOINT AT TOP FC3 CLOSET FC3 COVER O L.� AGAINST CONTACT. NO SHARP OR ABRASIVE OF COVE BASE & DISPENSER 7'-6" Z Z SURFACES UNDER LAV. FRP (TYP.) Cd TOILET ROOM ELEVATION TOILET ROOM ELEVATION TOILET ROOM ELEVATION TOILET ROOM ELEVATION v vJ 5 erxA5_4 4 _15_ro 3 fpA9er.ra 2 ecueVr.r< -- TOILET ROOM EQUIPMENT / ACCESSORIES SCHEDULE HC TOILET ROOMS ---_TI------- ------ N MARK DESCRIPTION. MOUNTING MFQ MFQ NO. REMARKS KOALA /KB200/ SUPPLIED BY TENANT CC-4 MISC. BABY CHANGING STATION X \ �h WHITE GRANITE INSTALLED BY G.C. VITREOUS CHINA WALL HUNG AMERICAN STANDARD LAVATORY � 0124.024.020 SUPPLIED AND INSTALLED SUPPLIED BY TENANT WHHITEIUCET, STOPS, DRAIN WALL COMRADE BY G.C. CC-5 MISC. CLOTHING HOOK PUCKS FIXTURE VENDOR X 1 INSTALLED BY G.C. \ C COMPLETE WIT , A O O P-TRAP AND WALL HANGER. FAUCET 6053.205 THESE ITEMS REPRESENT THE BALANCE OF THE TENANT ITEMS TO BE --- Cd FAUCET INSTALLED TO COMPLETE THE CUSTOMER CARE REQUIREMENTS. \ VITREOUS CHINA WATER CLOSET: - ACCESSIBILITY IGN 'I' L. =I OWC ELONGATED BOWL, SEAT, T TRIM TOTO SUPPLIED AND INSTALLED PER DETAIL. 5/pDA.1 1.6 GPF, WITH SUPPLY, STOP, AND WHITE FLOOR DRAKE SERIES CST7445L�F11 BY G.C. \ I O N OPEN FRONT SEAT 2 U O a 5 3 O 24" X 36" FRAMED MIRROR SURFACE BOBRICK B-165/2436 SUPPLIED AND INSTALLED i. 4 BY G.C. GB1 36" HORIZ. GRAB BAR SURFACE BOBRICK B-6806.99 X 36" EXISTING TO BE REINSTALLED, (PEENED) OR NEW SPEC IF NEEDED KOALA CHANGING eo STORE NUMBER STATION 4 GB2 42" HORIZ. GRAB BAR SURFACE BOBRICK B-6806.99 X 42" EXISTING TO BE REINSTALLED, `SEE DETAIL "A" (PEENED) OR NEW SPEC IF NEEDED iv _ ., 3,_6. A 1369 GB3 18" VERTICAL GRAB BAR SURFACE BOBRICK B-6806.99 X 18" EXIST ING SPEC IF NEEDEDG TO BE REINSTALLED, " TO 4 (PEENED) OR NEW A DF ISSUE HD SURFACE MOUNTED HAND DRYER SURFACE XLERATOR THINAIR SUPPLIED AND INSTALLED 'A'-ISSUE:PRELIMINARY TA-ABSBY G.C. DATE: 4/26/22 SERVICE SINK FLOOR FIAT TAT1 -ISSUE:ILL REVIEW / BID SET MS EXISTING TO REMAIN, c -,,, ,,., DATE: 5/6/22 FAUCET - SEE THIS SHEET WALL AMERICAN STANDARD #8344.012 OR NEW SPEC IF NEEDED 'C'-ISSUE:PERMIT SET WQ °D DRINKING FOUNTAIN WALL ELKAY /EZSTLVRBC B TP GB3 $C DATE: 6/14/22 DF EXISTING TO REMAIN. 'D'-ISSUE: ACCESSORY APRON WALL ELKAY �1LKAPREZL OR NEW SPEC IF NEEDED FL DATE: fO / y TOILET SEAT COVER DISPENSER SURFACE KIMBERLY CLARK KRY KD100 SUPPLIED BY TENANT 'E'-ISSUE: INSTALLED BY G.C. io GB1 / \ MS DATE: SC ACCESSIBILITY SIGN 'F'-ISSUE: TP TOILET PAPER HOLDER SURFACE KIMBERLY CLARK 09604 SUPPLIED BY TENANT _-J -DER-DETAIL-5/ADA.1 DATE: INSTALLED BY G.C. iv I SUPPLIED BY TENANT 1� SHEET TITLE SD SOAP DISPENSER SURFACE KIMBERLY CLARK 92145 INSTALLED BY G.C. I J3 I PLUMBING FIXTURE NOTE H.C.TOILET ROOM/ 1.) REFER TO PLUMBING SPECIFICATIONS SHEET FOR ADDITIONAL INFORMATION. F \ _1 HALL PLAN AND GENERAL NOTES FOR NEW TOILET ROOMS: M ELEVATIONS 1 INSTALLED BY G.C. SCALE .) ANY EXPOSED PLUMBING SHALL BE WRAPPED w/ HANDICAPPED APPROVED WHITE VINYL DRAIN COVERS SUPPLIED AND CITY APPROVED PLANS -� - � Ij l = ' 'L,l� 2.) REST ROOM VINYL TILE ON FLOOR SHALL COMPLY TO FED. SPEC. L-F-475A (3) TYPE II GRADE A. L e 0 - 3.) IN ADDITION, CLASS 'A' MARLITE F.R.P. UP TO 48" A.F.F. - COLOR = WHITE USE MATCHING MARLITE EDGINGS & Reviewed for Code Compliance _v------- --- AS NOTED CORNERS. SEAL PERIMETER OF F.R.P. W/ CLEAR SILICONE SEALANT. TYPICAL FOR ALL INTERIOR TOILET ROOM WALLS. 4.) PROVIDE NON-COMBUSTIBLE FRT IN WALL BLOCKING, IN ALL LOCATIONS OF EQUIPMENT AND ACCESSORIES REQUIRED PLANS MUST BE ON JOB SITE SHEET NUMBER TO BE WALL MOUNTED. 5.) REFER TO ACCESSIBLE ACCESSORY INSTALLATION DIAGRAMS THIS PAGE FOR ALL TOILET ROOM ACCESSORY INSTALLATION. FOR ALL INSPECTIONS HD 6.) G.C. TO PROVIDE SILICONE SEALANT JOINT AROUND ALL RESTROOM FIXTURES A3.3 TILT-EQMT-REV-o1 1 H.C.TOILET AND HALL ROOM PLAN ecwe Yz•ra Page 1 DATE: 4/26/22 �\ JOB NO: 22-010 8.0 DECK STAFF B.0 DECK -- 4"rvC cLFA M CHECKED: CM — PWG O W O Pw nE W Qb m I I M 0 M 0 44""2 NOIX PT2 PT2 PVC CAP }}p ON CENfPIERED T IN GACRER I wWO O LCP m C 0 R T L A: D 0 12 M 0 R G N Let •a rvc coup of i F�F21 o A R C H I T E C T r PVC CAP SLIP T. N H DD x & TRIM 711 N. FIELDER RD. ARLINGTON, TX 76012 / PH: (817) 635-5696 d / FAX: (817) 635-5699 D axs D Y LICENSED aa„s D B2 B2 ARCHITECT D 3 i AR-2098 D A DRAWING, HOLDER TUBE 8 INTERIOR ELEVATION INTERIOR ELEVATION �y naxs D CORTLAND MORGAN I I STATF GF IDAHG B.0 DECK B.0 DECK ------- 15'-10" A.F.F. 15'-9 1/2" A.F.F. E w w "s I �7 I PROJECT COORDINATION aa„s C' PT2 '� PT2 Oo (ADDTum 1 $ Zw�O111l1't"0 ROAD,CrV474 tDs FAILI l7ie�i-seW Ilal CITY APPROVED PLANS m $ ~ LL Reviewed for Code Compliance PT2 PT2 PT z `PT2 i LLI T LL `° DO R D OR 01 DOIQR & N F LLI Q rA F� ~¢ RIM & T TRIM - FRAME L V� PLANS MUST BE ON JOB SITE ° ' W W CM N ==i FOR ALL INSPECTIONS \ <~ / \ 3: Cf) e0 0) :D W 0 DRINKING Q 0 CIS B2 FOUNTAIN B2 � J 6 INTERIOR ELEVATION 5 INTERIOR ELEVATION Z J Q EXTEND GYP. BD. TO UNDERSIDE O FL LL PT2 OF JOISTS AT WALL STANDARD PT2 Z I LOCATIONS z COv CEI \ 15' DECK U a 15'-9" A.F.F. 15-9" A.F.F. `^ z z 6 aJJ w •� o 00•io / 42 T.O. STND ------- •I �d LO 0 12'-3" A.F.F. j 8 c 0 c %A m m I i i L ' CO B.O. STND E4 ___ ___ \ / \ / .6 m PT o m 0 6-3 A.F.F. -------- ------- �PT2 . m6. N F EG \/ \/ DbOR N F D R O I TRI w O •�• Ev /\ /\ & TR�M w ru �/• 0 U M 0 O 7j - I 0 , iz j I STORE NUMBER 'k = EMPLOYEE BREAK COAT HANGER HARDWARE HANGER 1369 B2 AREA TABLE, FIXTURE STORAGE B2 MANAGEMENT REFRIG, MICRO BIN KEY PLAN INTERIOR ELEVATION 3 INTERIOR ELEVATION ISSUE SCALE:N.T.S. EXTE YP. BD. TO UNDERSIDE 'A'-ISSUE:PRELIMINARY PT2 OF JOISTS AT WALL STANDARD PT2 DATE: 4/26/22 STOCKROOM EQUIPMENT SCHEDULE LOCATIONS 'B'-ISSUE: LL REVIEW / BID SET B.O. DECK B.O. DECK DATE: 5/6/22 MARK TYPE DESCRIPTION MFG./SUPPLIER OTY REMARKS 15'-7" A.F.F. 15'-7" A.F.F. o 'C'-ISSUE:PERMIT SET SE-1 MISC. EMPLOYEE BREAK TABLE OFFICE SUPPLY VENDOR I SUPPLIED BY VENDOR - u m DATE: 6/14/22 INSTALLED BY G.0 a x I SUPPLIED BY VENDOR rn w>w 'D'-ISSUE: SE-2 MISC. MICROWAVE OFFICE SUPPLY VENDOR 1 INSTALLED BY G.0 T.O. STND DATE:SUPPLIED BY VENDOR O 12'-3" A.F.F. SE-3 MISC. REFRIGERATOR OFFICE SUPPLY VENDOR 1 E'-ISSUE: INSTALLED BY G.0 (1) QUAD DATE: SE-4 METAL LOCKERS OFFICE SUPPLY VENDOR (2) BAY SUPPLIED BY VENDOR, ATTACH TO WALL NETWORK T 'F'-ISSUE: m � � � �IF � � I A (1) J-BOX DATE: CABI ET SE-5 METAL FLOOR SHELVING VENDOR 0 SUPPLIED BY VENDOR ❑ o III I I FF(1) IG DUPLEX m INSTALLED BY G.0 a o RECPT. a SHEET TITLE SE-6 METAL ROLLING SAFETY LADDER VENDOR 1 NOT SHOWN IN PLAN o cO .o III I I 0 cO SUPPLIED BY VENDOR T2 PT2 I cO Li LCP I cO 36 = STOCKROOM SE-7 MISC. DRY ERASER BOARD OFFICE SUPPLY VENDOR 1 INSTALLED BY G.0 D�OI DO PR o SE-6 MISC. WALL MOUNT CLOCK OFFICE SUPPLY VENDOR 1 SUPPLIED BY VENDORSLE TRI L5/TRIM c W I I MOBILE I •� W ELEVATIONS INSTALLED BY G.0 1 SE-9.1 MILLWORK HARDWARE BIN MILLSHOP t SUPPLIED BY VENDOR 00 I III I SCALE INSTALLED BY G.0 / \ B.O. STND --------- o ---------- I III I AS NOTED SE-11 MISC. FRAMED CORK BIRD. OFFICE SUPPLY VENDOR q SUPPLIED BY VENDOR P� O 2'-3" A.F.F. INSTALLED BY G.0 1 in SE-16 MISC. 32" HANGER MANAGEMENT VENDOR SUPPLIED BY TENANT SYSTEM 1 INSTALLED BY G.C. MOBILE SHELVING DRAWING SHEET NUMBER SE-19 EMPLOYEE COAT HOOK TENANT 1 SUPPLIED BY VENDOR HOLDER MISC. FIXTURE INSTALLED BY G.0 4 B2 A3.4 INTERIOR ELEVATION INTERIOR ELEVATION 2 1 Page r' • OFFICE EQUIPMENT SCHEDULE DATE: 4/26/22 MARK TYPE DESCRIPTION MFQ/SUPPLER CITY REMARKS JOB N0: 22-010 RE/SE-8 MISC. WALL MOUNT CLOCK OFFICE SUPPLY VENDOR I SUPPLIED BY TENANT INSTALLED BY T.G.C. DRAWN: STAFF SE-10.1 MILLWORK MANAGER'S DESK MILLSHOP 1 SUPPLIED BY TENANT T.O. STANDARD INSTALLED BY T.G.C. WITH 4 SUPPORTS 8'-8 1/2" A.F.F. CHECKED: CM (4) 12"D X 96" L SE-12 MILLWORK 24" W ROLLED CORK BRD. OFFICE SUPPLY VENDOR 1 SUPPLIED BY TENANT 2'-0" PLAM. SHELF. EDGE 4' SURFACE MOUNTED INSTALLED BY T.G.C. BANDED CUT TO STANDARDS SE-13 METAL (4) DRAW FILE CABINET OFFICE SUPPLY VENDOR 1 SUPPLIED BY TENANT FIT Ir,( �jf V UO INSTALLED BY T.G.C. PLAM WHITE \\�� SE-14 METAL (2) DRAW FILE CABINET OFFICE SUPPLY VENDOR 1 SUPPLIED BY TENANT PLAM. (PL- 1) INSTALLED BY T.G.C. 12" WOOD SHELF BRACKET SE-15 METAL SAFE OFFICE SUPPLY VENDOR 1 SUPPLIED BY TENANT B.O. STANDARDIl 0 R T L A N D INSTALLED BY T.G.C. PLAM 8��0 �p M D R D A JT SE-18 METAL NETWORK CABINET VENDOR 1 SUPPLIED BY TENANT INSTALLED BY T.G.C. WHITE W o NETWORK CABINET NEITALLATION RE X I8Y lEffM COUNTER M 711 N. FIELDER RD. 'do � ARLINGTON, TX 76012 1 '�' PH: (817) 635-5696 GENERAL THE FOLLOWING NOTES DESCRIBE THE RESPONSIBILITIES FOR THE NETWORK CABINET INSTALLATION. iv I 1 a FAX: (817) 635-5699 TENANT QC: TENANT VENDOR.COMMWORKB t-1/B" WHITE LL 1 (PLAM, EB) o PLAM. SHELF L ^ �j INSTALLS NETWORK SERVER CABINET AS SHOWN. �1 INSTALLS PATCH PANEL SUPPORTS M ❑2 INSTALLS SURGE STRIP ❑2 INSTALLS ST600 1 LICENSED ARCHITECT �3 INSTALLS UPS AR-2098 �3 INSTALLS STORE 6 SERVER (TO BE INSTALLED ONE ®MAKE CONNECTION TO POWER. DAY PRIOR TO POS INSTALL) TENANT VE9DM HUI NETWORK$ �j INSTALLS CISCO CATALYST SWITCH �2 INSTALLS 4700 ROUTER DESKDETAIL �CO�U��,f�fER SEC110N CORTLANO MORGAN STATF OH IOAHO �3 INSTALLS MODEM (UNLESS PROVIDED BY LOCAL) ®INSTALLS CRADLEPOINT (TO BE INSTALLED ONE DAY PRIOR TO POS INSTALL) PROJECT COORDINATION .� 225 OAKLAND ROAD,SUN 105 m:860 763-5670 SONH WINDSOR,Cr 06074 HA!( )M-5BBD ACTION REQUIRED ( carte � "` ' Design Directive ri: 0024.00 2" CONDUIT r$ 05H SH 3/4" CONDUIT Original Issue Date: 04.13.2016 I b IN WALL TO 6" IN WALL TO babies and kids $gJ5 ABOVE CEILING Revision Dates 00.00.0000 I I CEILING VE H Network Cabinet Installation Requirements (1) QUAD RECPT. I I w T LL Retail Store Network Cabinet Set Up o (1) PHONE RECPT. (f� � 04 (4 (1) J-BOX SPK I I VJ �_ WIRES OUTLINE OF Gatlkmipinwuntea NEW PA on eack6oartl our4ae I FLAT PANEL LU 0 3/4" CONDUIT IN MONITOR me inet luntss WALL TO 6" DUPLEX L•� ,V,,1 bength spoor) �" 1,-2„ 1- I I ABOVE CEILING RECPT. Q 0 C EMERGENCY r oo I 11 I FOR TECH II II J plch Penes PANIC BUTTON I f r,mltd Imp or MOUNTED UNDER < 1 J Z J 6a center COUNTER ® LL= JL O J'! L.L nu�eaourer, m e (1) J-BOX FOR LL A` PRINTER modem,nd— 2'-11' 1'-1" V p�edontopof LOCATION OF ® I o COUNTER I Z CIj CL /'� SUPPORTS '^ /V��! �VJ o��, i 5mrc 65erverv[s 'Z'—D» 2r-0w D _ (2) DUPLEX RECPT. �� u onbosomot p (1) PHONE RECPT. � � NI E 23.68' � case C COUNTER ELEVATION B COUNTER ELEVATION A COUNTER ELEVATION C 0 HOTES: m 4J Cabinetto belns lied by o,nstrucd,n prior toCommWorksVisit,induding5urge Stripand UPS installed (3/4") IN I L =I and connected to power outlet 3—O» PT2 PT2 WALL CONDUITS O .w Hughes Installs•.ClscoCtI,,st SMth,Hcghes 4700 Router,Modern(inless provided by l owl provider, B.O. CEILING B.O. CEILING _0» (3/4") IN WALL U O me providers i—Ilthe modematthe phone board),CndlWointon Mughes Install date(day before STUB—OUT CONDUIT F IN WALL ABOVE 10-0 A.F.F. 10-0 A.F.F. CONDUITS SUPPLIED Pos inrt ll date) OFFICE CLG. AND INSTALLED BY Comm Works Installs:Patch Panel,STti00 and Store 6 Server a[P051rsg11 tla� I IA1 G.G. 2" CONDUIT IN I STORE NUMBER Affected Projects: NI20165tores tha[have not yet apenedand where daangecan be affected. WALL TO J-BOX er_-e PT2 FD 4X4 J-BOX J °� I DO & °p ti o Dig Z Anecrenoi..ipllne:/oepanmant:: (D FRA `` I a� ArhRects,CPM's, m I r1 C a1369 NETWORK CABINET OUTLINE OF t� D- INSTALLED ON 10U NET ORK NEW 17" � I ~ -p 3E-14 MOUNTING BOARD CABINET FLAT PANEL MONITOR ISSUE 4G UNIT Z 'A'-ISSUE:PRELIMINARY 2- X 3' X 5/8" FRT o DATE: 4/26/22 PLYWOOD MOUNTING �yp� 4 W BOARD PAINT WHITE "' I `o e Z 'B'-ISSUE:ILL REVIEW / BID SET B2 B2 5 ^^ 3 � I = I 1 DATE: 5/6/22 DUPLEXRECEPTACLE ♦ m S m 'Cl-ISSUE:PERMIT SET nINTERIOR ELEVATION nINTERIOR ELEVATION ♦ g DATE: 6/14/22 'D'-ISSUE: DATE: Z T-ISSUE: B.O. CEILING - B.O. CEILING \ �o DATE: 10-0 A.F.F. 10'-0 A.F.F. 0T.O. STND 1/2" \ o o Z 'F'-ISSUE: CITY APPROVED PLANS 8'-2 2" A.F., DATE: 0j to (r1J I o I -- --- SHEET TITLE Reviewed for Code Compliance - aN °p (2") IN WALL J PLANS MUST BE ON JOB SITE FRAME PT2 0 ` = rn CONDUIT (TECH I I - (2") IN WALL OFFICE PLAN �\ (1) ROLLED I EQUIPMENT g L----J CONDUIT AND ELEVATIONS FOR ALL INSPECTIONS CORK B safe COUNTER `-+�+ _ - SE-18 SCALE �\ c SUPPORTS I _ -L 7. 4 R N AS NOTED 7,_0„ B2F_BL271 ROOM DIMENSION SHEET NUMBER n INTERIOR ELEVATION n INTERIOR ELEVATION n INTERIOR ELEVATION !1 1 OFFICE PART FLOOR PLAN /� Pa e DATE: 4/26/22 JOB NO: 22-010 DRAWN: STAFF CHECKED: CM C M C 0 R T L A N 0 M 0 R G A N ARCHITECT NOTE: ALL MATERIALS SUPPLIED NOTE: BENCH SHALL BE CAPABLE 711 N. FIELDER RD. BY MILLSHOP I OF SUPPORTING 250 LBS/FT I ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 EX. WALL STUDS 0 8" O.C. LICENSED AT BENCH ATTACHMENT ggcHI7ECT SIDE LOCATIONS (TYP.) \ 24" \ A HAN I APPED BE C 1 X 3 WITPLAM V MDF PL2 iv WITH PLAM COflTLANO MORGAN GigTF Of IOAHG PROJECT COORDINATION M CADDTuri 1/2" vs OAKLAND Row,sane ros m:(Bfi1 1ss-ssro SOWNMNDSDP cr owT� RA1:(a WIM I I I I I I W T LL HWp (f) RTTNO ROOM WALL SECTION W c) N N ecusiYR'a< ` '^ — 00'Z V, 0) W 0 0= RTTING ROOM RXTURES AND ACCESSORIES J MARK LOCATk�N TYPE DESCPoPTION SUPPLIER PART OTY REMARKS Z _j Q 24" D X 48" L X 18H H.C. SUPPLIED BY MILLSHOP O LL LL V BZ FITTING ROOM MILLWORK FITTING ROOM BENCH MILLSHOP X INSTALL BY T.G.C. Z CO Z Cd HI FITTING ROOM MILLWORK FITTING ROOM CLOTHING HOOK MILLSHOP FR3 1 SUPPLIED BY MILLSHOP Q CL INSTALL BY T.G.C. U V/ MI FITTING ROOM MILLWORK 30" x 72" FRAMED MIRROR MILLSHOP X SUPPLIED BY MILLSHOP INSTALL BY T.G.C. L $Al oolft RttingR CITY APPROVED PLANS O Reviewed for Code Compliance L a& PLANS MUST BE ON JOB SITE p L =I VFOR ALL INSPECTIONS O / FIXED H.C. 4'-0" a BENCH SEE STORE NUMBER DETAIL "A" BENCH SIGN PER DETAIL PT2 GRAPHIC BY 1369 3/ADA1 SHEET DOOR TENANT SIGN & TRIM CONTRACTOR z ISSUE of z 'A'-ISSUE:PRELIMINARY �1 RITM ROOM ELEV iv m DATE: 4/26/22 V ecraaYr no B2 ' 'B'-ISSUE:LL REVIEW/ BID SET ro DATE: 5/6/22 I Fry A 'C'-ISSUE:PERMIT SET / DATE: 6/14/22 ,D, ATE!: PT1 PT1 PT1 PT1 80 O 4 _ 6 'E'-ISSUE: = DATE: B.O. CLG. B.O. CLG. B.O. CLG. B.O. CLG. 8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. 8'-0" A.F.F. 'F'-ISSUE: GRAPHICS DATE: COAT HOOK BY SIGN FIXTURE BY CONTRACTOR SHEET TITLE MILLSHOP FITTING ROOM FIXED AND ELEVATIONS BENCH FITTING IT ROOM BENCH 2'-0" o SCALE FRAMED 6-8. AS NOTED 81 B1 MIRROR BY PT2 B1 B1 MILLSHOP DOOR & TRIM SHEET NUMBER 5 FMM ROOM ELEV 4 RTTNQ ROOM ELEV 3 RTTM ROOM ELEV 2 RTTM ROOM ELEV 1 RTTm ROOM PLAN DETAL A3.6 Pa e DATE: 4/26/22 JOB NO: 22-010 DRAWN: STAFF CHECKED: CM SECURE CABINET TO EXISTING MONITOR WALL STUDS 48" O.0 AT 3RD CARD SWIPE POINTS VERTICALLY WITH #10 M SCREWS (TYP.) KEY PAD RECEIPT C G R T L A N G PRINTER N 0 R G A N ARCHITECT ADJ CASH DRAWER CASH DRAWER SHELVES 711 N. FIELDER RD. ARLINGTON, TX 76012 o PH: (817) 635-5696 FAX: (817) 635-5699 LATCH LICENSED in ARCHITECT I AR-2096 DRAWER ADJ. SHELF W/FINGER PULL J SAASHWRAP REAR ELEVATION s/r-ra C6RTLAN6 MDRGAN 0 STATE OR IDAHO ADJ '^ SHELVES -8" 7'-4j" PROJECT COORDINATION CADDTccri DRAWER 225 OAXUND ROAD,SUITE 105 TEL(8601 783-5670 SOUDI WINDSOR,CT 06074 FAX: ( )783-5680 c O ADJ T N SHELVES T N Lu r LL O O O U) ccL� CID OM CI) W r co CV N N / Vrr1 00 BACK WRAP SECTION W� �V' WCALE9/4'•T-0' Iy Q0Cn C) CCI J 0) 0 E: LL Carter's CASHWRAP FRONT ELEVATION Z c� Z /�� G BCAlla 9/r-T4 Q �L�1L T1 7-4 U H VJ T I r I . AA � - o UPPER CABINET j ku, WITH GRAPHIC m PANEL INSERT _ CITY APPROVED PLANS r O - Reviewed for Code Compliance :R:EGIITER } --JPLANS MUST BE ON 10B SITE -- RiGi4dll x FOR ALL INSPECTIONS STORE NUMBER 4 CONDUITS 1369 IIIII STUBBED UP 5 \ \ \ ISSUE i i i o c 'A'-ISSUE:PRELIMINARY T 5 1" CONDUITS / / DATE: 4 26 22 3'-0" UNDER FLOOR 'B'-ISSUE: LL REVIEW / BID SET DATE: 5/6 'C'-ISSUE: PERMITT SET DOORS AND DRAWER DATE: 6/14/22 DRAWERS WHITE FINGER ' '-ISSUE: PULL PLAM. PULL I I I I I DATE: �1 BACK AP ELEVATION U 'E'-ISSUE: V ecu&s/4•-Ta DATE: N N F'-ISSUE: DATE: 7 -T SHEET TITLE M ili it CASHWRAP / M ili 4 N BACKWRAP PLAN III II +18" A.F.F. +18" A.F.F. 7•-4" AND ELEVATIONS -------- -- ----- SALE 4" V-11}" 4" TOE KICK AS NOTED 2'-71" IN-WALL CONDUITS 7'-44' SHEET NUMBER COUNTER TOP BACKWRAP PLAN CASHWRAP END ELEVATION CASHWRAP/BACKWRAP PLAN A4.1 �'F BCOlE+9/<'-4-0' I BCRLE J/!•TV ��1/9CRLB Pa e DATE: 4/26/22 JOB NO: 22-010 DRAWN: STAFF CHECKED: CM cc M C 0 R T L A N 0 M 0 R G A N ARCHITECT 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 LICENSED ARCHITECT AR-2098 WALLS PT1 T1 CORTLAND MORGAN STATE OF IDAHO 9 1.2 PROJECT COORDINATION T.O. STANDARD CADDTuti 8'-2" A.F.F. 225 OAKIAND ROAD,SUITE 105 TEL:(8601 783-5670 SOUTH WINDSOR,CT 06074 FAX:(6500)793-5680 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I W U w O `^ `f V J W Cl) N I I I I I I 00 T ` W Q O C M `�J 1 J J in Z I Q I J ^` 0 LL LL. W Z V PT1 _ Ij.K C�. `v Tl I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I O L I I I I I I _ I II I I I I I B.O. STND /\ O 4" A.F.F. V V PT1 1/2" X 5 1/4" BASE B1 STORE NUMBER WITH 1/2" X 3/4" BASE SHOE 1369 7'-5" SURFACE in MOUNT STNDS WHERE THEY OCCURE ATYPICAL WALL DISPLAY ELEVATION G ,21r ISSUE 'A'-ISSUE:PRELIMINARY DATE: 4/26/22 'B'-ISSUE: LL REVIEW / BID SET DATE: 5/6/22 1'-6" 'C'-ISSUE: PERMIT SET DATE: 6/14/22 'D'-ISSUE: DATE: 'E'-ISSUE: DATE: I I 'F'-ISSUE: I I DATE: I I I I SHEET TITLE I I B1L---------------------__------_ ---_-----. WALL DISPLAY 2 3 CITY APPROVED PLANS DETAILS SCALE Reviewed for Code Compliance AS NOTED PLANS MUST BE ON JOB SITE �,� =ICAL WALL DISPLAY SECTION �i1TYP L PERIMETER WALL DISPLAY PLAN SHEET NUMBER v ..,� , ..,� FOR ALL INSPECTIONS A4.2 Pa e (EXISTING) ROOF SYSTEM RIGID INSUL. (EXISTING) ROOF SYSTEM RIGID INSUL. DATE: 4/26/22 AND MEMBRANE ROOF OVER WOOD AND MEMBRANE ROOF OVER WOOD JOB NO: 22-010 DECK, AND WOOD JOISTS. DECK, AND WOOD JOISTS. 2 X 4 WD BLOCKING DRAWN: STAFF CHECKED: CM B.C. DECK B.O. DECK 16'-3" A.F.F. (CENTER) 16'-3 A.F.F. CENTER CITY APPROVED PLANS I 3 3 5/8" X 20GA DEEP LEG SLIP METAL TRACK �jl V U 0 Reviewed for Code Compliance TO UNDER SIDE OF DECK O EXISTING WOOD ROOF EXISTING WOOD ROOF TRUSSES WHERE (2) #10 SCREWS TO EA. TRUSSES WHERE PLANS MUST BE ON JOB SITE THEY OCCUR METAL STUD THEY OCCUR C 0 R T L A N D FOR ALL INSPECTIONS M 0 R G A N ARCHITECT 3 5/8" X 20 GA DIAGONAL BRACING O 3 5 8 X 20GA RLI T FIELDER RD. 2 ' 48" O.C. ALTERNATING METAL RACK PH: ( 17)ON, TX 5696 012 A5. ^ TO THE STRUCTURE PH: (817) 635-5699 FAX: (817) 635-5699 3 5/8" X 20GA METAL TRACK B.O. ACT. CLG. B.O. ACT. CLG. LICENSED 10'-0" A.F.F 10'-0" A.F.F ARCHITECT AR-2096 ACOUSTICAL CEILING ACOUSTICAL CEILING O 0 WALL BRACING O He'OC. 1'X 5'WHITE WIRE GRID I • PER WALL SECTION PANEL WRH 3'SO'S,IRON 0 ip ECONOCO RENT GW15 COflTLANO MORGAN 1'STAINLESS WASHER EACH 8.0. CEILING STATF Of IOAHO LOCATION 8'-0" A.F.F. 3 5/8" X 20GA METAL STUDS O 16" W/ 5/8" ACOUSTICAL CEILING TYPE "X" GYP. BD. FULL %*EYE DOLT WWH TOGGLE HEIGHT SALES SIDE. O PROJECT COORDINATION TE HOOK FROM /�DDT��� -MERCHANDISING INVENRVEY 3 5/8" X 20GA METAL \/` I ITEM i)015RI.J0 STUDS O 16" O.C. 5/8" o 0 1z• �. TYPE "X" GYP. BD. TO 6" •o •o rNM L7o miE 1�u.(em)mi e i ABOVE CEILINGS USE TYPE TRACK LIGHTING MR GYP. BD. IN WET AREAS. OALI A,REQUIRED C-HOOKS LENGTH AS REWIRED FOR HEIGHT RCHANDISING IVENTIONG AVAILABLEE ♦'- M x•LoxG OFFICE STOCK OFFICE FITTING ui 0 U7 O 3 5/8" X 20GA TRACK W � N (2) #10 SCREWS To EA. 5 a) METAL STUD & SECURED r , 1 , TO SLAB W/ POWDER I l �z LU i ACTUATED FASTENERS A+r• FLOOR ELEV. I FLOOR ELEV. O C M 0-0 �� 0-0 HJ J n STOFaEF RONT MARKE rING OFID INSTALLATION 6 WALL SECTION 5 WALL SECTION J J Zsrr-ra ..rrr-ro .arr-ro _3O Ea (EXISTING) ROOF SYSTEM RIGID INSUL. (EXISTING) ROOF SYSTEM RIGID INSUL. (EXISTING) ROOF SYSTEM RIGID INSUL. 0 Ff L.L AND MEMBRANE ROOF OVER WOOD AND MEMBRANE ROOF OVER WOOD AND MEMBRANE ROOF OVER WOOD Z V DECK, AND WOOD JOISTS. DECK, AND WOOD JOISTS. DECK, AND WOOD JOISTS. Z Cd 2 X 4 WD BLOCKING 2 X 4 WD BLOCKING (2)3 5/8" X 20GA METAL STUD BRACES r3 L. B.O. DECK B.O. DECK D 48" O.C. W/I" GYP. DETAIL -A B.O. DECK U 1 Cn 3 5/8" X 20GA METAL 16- A.F.F. E 1 - A.F.F. CENTER 16-7 A.F.F. FRONT STUD TRACK SECURE TO 3 3 3 5/8" X 20GA METAL 16'-3" A.F.F. (CENTER / EXISTING WALL STUDS 3 5/8" X 20GA DEEP , 3 5/8" X 20GA DEEP STUD TRACK WITH #10 SCREWS LEG SLIP METAL TRACK LEG SUP METAL TRACK A TO UNDER SIDE OF DECK TO UNDER SIDE OF DECK EXISTING WOOD ROOF F ME L ME SCREWS TO SCREWS TO EA. INSTALL 2 X 6 TRUSSES WHERE O METAL STUD METALL STUD T BLOCKING WHERWD E REQUIRED (1f A ,O L EXISTING EXTERIOR m 6 I I FACADE w GE 3 5/8" X 20GA 3 5/8" X 20GA -� r - > METAL TRACK METAL TRACK T.O. S.F. FRAME 9-11 O OUTLINE OF STOREFRONT STORE NUMBER TRACK LIGHTING B.O. ACT. CLG. ACOUSTICAL ACOUSTICAL 1369 10'-0" A.F.F CEILING CEILING ACOUSTICAL CEILING TRIM, O O ISSUE T.O. STANDARD T.O. STANDARD j 6 T.O. STANDARD 'A'-ISSUE:PRELIMINARY DATE. 4/26/22 8-2 A.F.F. 8-2 A.F.F. O 8-2 A.F.F. EXISTING EXTERIOR WALL 7'-5" WHITE SURFACE MOUNTED 'B'-ISSUE:LL REVIEW / BID SET 3 5/8" X 20GA METAL 3 5/8" X 20GA METAL CONSTRUCTION: E.I.F.S. OVER DATE: 5/6/22 3 5/8" X 20GA METAL STANDARDS O 18" O.C. G.C. TO STUDS O 16" W/ 5/8" STUDS O 16" W/ 5/8" WOOD SHEATHING AND WOOD TYPE "X" GYP. BD. FULL TYPE "X" GYP. BD. FULL STUDS O 16" O.C. W/ EXISTING STUDS, FULL THICKNESS SUPPLY AND INSTALL WITH HILTI 'C'-ISSUE:PERMIT SET 5/8" TYPE "X" GYP. BD. STOREFRONT #2158771 TOGGLERS DATE: 6/14/22 HEIGHT SALES SIDE. HEIGHT SALES SIDE. 4 FIBERGLASS INSULATION AND VERTICALLY 12" O.C.. GYP. BD. INTERIOR 'D'-ISSUE: 7'-5" WHITE SURFACE MOUNTED 7'-5" WHITE SURFACE MOUNTED DATE: nj STANDARDS O 18" O.C. G.C. TO STANDARDS O 18" O.C. G.C. TO 'E'-ISSUE: o SUPPLY AND INSTALL WITH HILTI _ SUPPLY AND INSTALL WITH HILTI 7'-5" WHITE SURFACE a, _ DATE: o2158771 TOGGLERS in #2158771 TOGGLERS VERTICALLY 12" O.C.. I# VERTICALLY 12" D.C.. °n MOUNTED STANDARDS O in 'F'-ISSUE: � 18" O.C. G.C. TO SUPPLY DATE: AND INSTALL WITH HILTI #00374500 TOGGLERS SHEET TITLE VERTICALLY 12" D.C.. EXTERIOR RETAIL OFFICE RETAIL HALL RETAIL RETAIL O RETAIL EXTERIOR INTERIOR SECTIONS B.O. STANDARD B.O. STANDARD 3 5/8" X 20GA TRACK B.O. STANDARD SCALE 0-9 A.F.F. , METAL STUD & SECURED 0-9 A.F.F. SCREWS TO EA. 0-9 A.F.F. in _ 11_On ME I 1 1 1 TO SLAB W/ POWDER AS - A5. ACTUATED FASTENERS FLOOR ELEV. FLOOR ELEV. FLOOR ELEV. SHEET NUMBER 0' -0 0-0 0-0 WALL SECTION s ALL SECTION 2 WALL SECTION 1 WALL SECTION A 5.1 `•F lcuas-rr ...rr•ro ...rr•ro .rr.r•rc Page DATE: 4/26/22 JOB NO: 22-010 DRAWN: STAFF CHECKED: CM �0 C 0 R T L A N 0 M 0 R 0 A N ARCHITECT 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 LICENSED ARCHITECT AR.2098 Y' CORTLAND MORGAN STATE OF IDAHO 2 X 4 WD BLOCKING SECURE TO TOP CHORD TRACK TO BLOCKING WITH PROJECT COORDINATION OF TRUSS (2) #10 SCREWS CADDR(ri 225 OAKLAND ROAD,SUOE 10s lFl:(866 78i-5670 SO M WINDSIN,CT 06074 FAX:(�)763-5680 EXISTING ROOF SYSTEM OVER WOOD DECKING AND WOOD ROOF TRUSSES L r DEFLECTION GAP L w r rj^ EXISTING ROOF SYSTEM r O U) co TRUSSES WOOD ECKING AND WOOD METAL STUDS PER SECTION w I— M N + + HORIZ. BRIDGING: 1 1/2" COLD a) w HEIGHT PER PLAN DEEP LEG SLIP TRACK WITH =. ROLLED CHANNEL CONTINUOUS ``// r.F #10 SCREWS AT EACH STUD SECURE TO EA. 16" O.C. STUD W/ Y V UNISTRUT CHANNEL J-BOX EACH SIDE 2" X 2" X 16GA CLIP ANGLES (2) 1y O r^ P-2000T #10 PWH SCREWS EA. CONNECTION "T" SERIES 1 J" X 1 Q V, PER STUD MANUFACTURES �^W 1 �" REQUIREMENTS LL J UPPER MOST PUNCH-OUT GYP. BD. PER SECTION J J 0 — LLLL � THREADED ROD FLEX CONDUIT, >_ LL V 4' O.C. TYP. SECURE TO ALL THREAD DROP > ,^S TOP TRACK TO STRUCTURE DETAIL Z UNISTRUT 1 1" CHANNEL SCALE:3'-T-0' Q 'Q NUT W/ SPRING P1008 V U J r TRACK END FEED UNISTRUT CHANNEL P-2000T "T" SERIES 1 J" X 1 R.O. TRACK SUSPENDED CEILING NOTES: HEIGHT PER PLAN 1.ALL HANGER O BRACING WIRES SHALL O TT O BE SECURED TO MAIN RUNNERS. V 2. PROVIDE TRAPEZE OF OTHER SUPPLEMENTARY SINGLE CIRCUIT TRACK SUPPORT MEMBERS AT OBSTRUCTIONS Cd TO MAIN HANGER SPACING. PROVIDE ADDITIONAL 3 5/8" X 20 GA TRACK HEADS HANGERS STRUTS OR BRACES AS REQUIRED 3"X3"X3"X 18 GA CLIP ANGLES AT ALL LILG. BREI.KS SOFFITS, OR DISCONTINUOUS DIAGONAL BRACING ® TO TOP TRACK AND DIAGONAL AREA. HANGER WIRES THAT ARE MORE THAN 48" O.C. ALTERNATING TO �I ca 1 INS 6 OUT OF PLUMB ARE TO HAVE COUNTER O BRACING W/(2) #10 SCREW I SLOPING WIRES. THE STRUCTURE CONNECTIONS, EA. LEG. CLIP O 7 TRACK LIGHTING INSTALLATION DETAIL OA MAIN SUPPORTS: ANGLES AT 48" O.C. MAX. '` �('01 F:3/47 11-T 12 GAUGE HANGER WIRES AT 4'-0"O.C.EACH WAY 0 M BO PERIMETER WIRES: F U O 12 GAGE PERIMETER WIRES INSTALLED WITHIN 8"OF WALL 3 5/8" X 20 GA TRACK AT EACH MAIN AND CROSS TEE TO WALL JUNCTURE EXISTING ROOF SYSTEM OC LIGHT FIXTURE SUPPORT: OVER WOOD DECKING AND 12 GAGE WIRES ATTACHED TO MAIN OR CROSS TEES WITHIN 3" STORE NUMBER WOOD ROOF TRUSSES OF FIXTURE AT EACH CORNER. AND 12 GAGE SAFETY WIRES ATTACHED TO FIXTURE(OPPOSITE CORNERS),EXTENDING TO STRUCTURE ABOVE. INSTALL ONE SCREW AT OPPOSITE CORNERS OF FIXTURE TO MAIN 1369 OR CROSS TEES. ACOUSTCAL CEILING ACOUSTCAL CEILING UNISTRUT CHANNEL P-2000T B "T" SERIES 1 a" X 1 �" PARTITION PER SECTION ISSUE 'A'-ISSUE:PRELIMINARY SAFETY DATE: 4/26/22 B.O. DECK WIRES 'B'-ISSUE:LL REVIEW/ BID SET HEIGHT PER PLAN DATE: 5/6/22 CREW 'C'-ISSUE:PERMIT SET SWIVEL MOUNT 4 X 4 J-BOX AT DECK 7 n TOP TRACK TO BRACE DETAIL DATE: 6/14/22 TO UNITSTRUT Ir L SCALE:3'4-0' 'D'-ISSUE: 0' DATE: A7 T-ISSUE: .. :'.. DATE: _ CITY APPROVED PLANS F,DATE: E METAL STUDS AT 16" O.C. Q A W/ GYPSUM BOARD PER i Reviewed for Code Compliance SECTION DETAIL SHEET TITLE PENDANT STEM PROVIDED SCREW -). CUT TO LENGTH AS NEEDED PLANS MUST BE ON JOB SITE MTL. TRACK PER SECTION DETAIL INTERIOR LIGHT FIXTURE \ HILTI X-U-PB POWDER ACTUATED CEILING TILE FOR ALL INSPECTIONS FASTENERS 16" O.C. DETAILS �. SHANK LENGTH 1" �� SHANK DIAMETER .16 INCH SCALE LIGHT FIXTURE I CONCRETE SLAB AS NOTED B.O. FIHLIG.XTURE yy METAL "T" BAR SHEET NUMBER PENDANT LIGHTING INSTALLATION DETAIL SUSPENDED CEILING DETAIL 1 TRACK TO SLAB DETAIL A5.2 6 SCALE:3/47-T-0' SCALE:N.Ts SCALE;3,-1'-0' Page DATE: 4/26/22 DENSTOR JOB NO: 22-010 STORAGEMOBILE ���������������� DEMO R IIIIIII1•�1•'•® D��Rk DRAWN: STAFF ' - " •'"""' -"" - " " "-" '-' i' MOBILE STORAGE SYSTEMS INC. MOBILE STORAGE SYSTEMS INC. CHECKED: CM 966WIIwn Orive NW a e MI49534-P:isax ]4]J•F:616969-COO1•dealers®oioomablle<om. � <nmue nonar ens orc n ri a 109534. -d1l,kn.-BIlbikmm ^ s • c Flat Track Heavy-Duty Manual System Specifications Flat Track Mechanical-Assist IRDFI System Specifications Flat Track System GENERAL SPECIFICATIONS:The mobile Sys em utilizes carriages and track to increase storage density by compacting rows GENERAL SPECIFICATIONS:The mobile system utilizes carriages and track to increase storage density by compacting of shelving into a single aisle configuration thus converting fixed aisles Into storage space thereby greater storage density Flat Track System is an alternative to our standard"V"Groove track.The Flat Track maintains the standard featuresofour rows of shelving Into a single aisle configuration thus converting fixed aisles into storage space thereby greater storage and mallawcicessgali ed.Rred of shelving on a carriage are quickly and easily moved via a mechanical-assistdriveandhandle "V"Groove track and incorporates the same ease of installation.The Flat Track is manufactured with a low profile and opened density and capacity is gained.Rows of shelving on a carriage are quickly andeasily moved to allow access to a desired C N 0 sides eliminating tripping hazards and making it easy for carts and other equipment to be moved in and out of the aisle. fON'' FLATTRACK MECHANICAL ASSISTCARRIAGES:Non-welded unitized carriage frames of anodized 6063-T5}3/8"x 2" Thei'latTrackis ADA-mpliantand is available with our built-in In Track Anti-Tip safety feature. aluminum angles with powder coated steel corner or center plates and rubber bump cushions joined by four seK-tapping (I R T L A N 0 FLATTRACK HEAVY-DUTY MANUAL CARRIAGES:Non-welded unitized carriage frames o(from and rear anodized 10-32 x 1-12'machine screws to end and intermediate anodized 6063-TS 3-7/32"z 1-7/8'extruded aluminum channels 6053-T53-3/8"z2'aluminum angles with powder coated steel corner or center plates and rubber bump cushions joined with four patented incorporated channel embossments.Each channel housestwo or three flanged wheel assemblies, M 0 R G A N Sta ndard Flat Track is 2-1/4"wide,3/8"at its highest point and is by four self-tapping 1432 z 1-1/2"machine screws o end and Intermediate anodized 6063 5 3-7/32'z 1-7/8'eAruded positioned under each shelving upright post ar back-to-back po n transferring the load to the ruck Wheels are 1018 steel, madefrom heat treated aluminum.lt hasa flat steel insettthat is 5/8" aluminum channels with four patented incorporated channel embossments.Each channel shall house three,positioned 3-1/2"diameter,supported by two,mounted flanged ball bearings.Channels are drilled with computerized axle drilling at A R C H I T E C T wide in place of the"V°groove.This will reduce debris in the track.There under each shelving upright post or back-to-back ports,load bearing 3-12'diameter double-flanged 1018 carbon steel all wheel locations to guarantee precision.Idler rolling wheels mounted via lubricated and sealed ball bearing race with ad uaceoi within ill retie debris i the tranbe wheels.Channels are drilled with computerized axle drilling at all wheel locations to guarantee precision.Casehardened 3/16'sidevi movement with both having precision machined steel axles.All wheel channels have drive wheels.The is o j tywi y steel drive wheels are mounted into the channel via high-speed roller conveyor flange ball bearing assemblies and idler drive wheels are attached to drive box s rocket,full length, wall steel tube.For ease of transportation leveled through shimming.This track can be used with the standard flat rolling wheels mounted via lubricated and sealed ball bearing ace with 3/16"sideways movement with both havingiages p 9 711 N. FIELDER RD. track carriage. precision machined steel axles.For ease oftransportution and handling,carriages longer than 192"will be shipped in left and handling,Height fromfloongerth of 192"we gle(shedln leftunti and gsht halves with one factory than 4-5/16repared lap splice per ARLINGTON, TX 76012 and carriage.Height from floorto top of carriage angle(shelving mounting surface)shall not be more than 4-5/16: anew,washers withone factory preparallach d lap 6063-Tplice 3/3/8" 2"x12'alu inumce splice anglst e%-2ghtfro round he to machine ` PH: (817) 635-5699 washers and W-20 nuts to attach 6063-T53/3/8"x2"xi2'aluminum splice angle.Height from floor to top of FLATTMCK MECHANICAL-ASSIST DRIVES:The carriage will have mechanically assisted 16:1 atlodrive ry5[em which FAX: (617) 63rJ-5699 0.375 damage angle(shelving mounting surface)shall not be more than 4-5/16'The maximum length of the carriage Is 12:The drives wheels In the carriage channels the full length of the carriage to eliminate'lag".The carriage will have a low profile, heavy duty manual carriages are rated at 3,000 lbs.The carriages can handle significantly more load,however,3,000 tbs.is drive box assembly,protruding no more than 5-1/2'from the front of the carriage.The drive box is covered by a durable 2.250------- � the maximum a person can move. 1/8"[hick ABS with texture black cover.Anergonomicallydesignedsinglepronghandlemolded ofindustdalstrength polymer,colored black with a mate grain finish,creates easy carriage movement The handle assembly includes a large -detent"to pull for releasing the carriage safety parking/locking mechanism.The Detent is spring loaded to ensure the LICENSED carriage will stay locked when engaged.An optional key lock shall be available and be easily field Installed.The drive box ARCHITECT Heavy Duty Flat Track is less than 3-1/a"wide,1/2"at its highest point upper and middle sprocket will be connected by a 95 link"I roller chain and the middle and lower sprockets connected AR-2098 and is made from aluminum.It has a flat steel insert that I,%"wide.This track by a 87link#41 roller chain,each with an average tensile strength of 2700 tbs.and a minimum ANSI strength of 1500 tbs. will eliminate debris in the groove.There is no adjustability within the track Chain tensions are to be maintained by use of upper and lower chain steel and nylon idlers which are attached be the drive for this style but this track can be leveled through shimming.This track can 721'x 301 Track Heavy-Duty Manual Carriage box assembly and are fully adjustable.One handle turn/drive revolution drives the carriage,approximately 3-1/2. be used with the heavy duty flat track carriage and the mechanicalsist M carriage. -as FUITTCK Stan dad track construction is 3-1/4'wide X'h°high,6063 aluminum extrusion base with sA'z 3/8"1018 cold _e roll steel wheel rolling insert to provide 3/4'wide,matched to wheel hardness,wheel-to-insen contact surface for strength FLA7TRACK:Standard track construction is 3-t/a'wide 6063 aluminum extrusion base with ls°x 378'7018 cold roll steel and durability.Track shall be top of floor mounted and ADA compliant to eliminate need for deck and ramp and designed CORTLANB MORGAN wheel rolling insert to provide 3/4'wide,matched to wheel hardness,wheel-to-insert contact surface for strength and to carry a minimum load of 1000 Has.per linear carriage foot Track sections will have lap splices,no buttjoints nor exhibit STATF 0T IOAHO oT.soo durability.Track shall be top offloor mounted and ADA compliant toeliminate need for deck and ramp and designed to carrya minimum load of1000 tbs.per linear carrlagefoo.Track sectlonswlll have lap splices,no buttjoints norexhibd movement ordeflection during operation ofmovable caniag—Track will be fastened tothe floorthrough factory drilled movementor deflection during operation of movable carriages.Track will be fastened to the floor through factory and countersunk hole in steel rolling insert,so screw head will be flush or belowtop of steel,and matching slot in the drilled and countersunk hole in steel rolling town,so screw head will be flush or below top of creel,and matching slot aluminum extrusion using 1/4 x 2'Hilti Sleeve Anchors placed on average 16"apart. in the aluminum extrusion using 1/4 x 2'Hiki Sleeve Anchors placed on average 16"apart Tracks with center gmove FLATTRACK END STOPS:Standard tr m crack end stop is 1-1/2"diaeter rubber cushion reinforced with an internal steel In-Grow nd Flat Track overall is 2-1/2'wide and V high.When instal led, that accept a center flanged wheel are not acceptable due to the potential collection ofdirt/debris in this groove nor are washer.End stop attached at each end of track run through pre-drilled factory hole with Hill 11 Wx 3-1/4"anchor. PROJECT COORDINATION tracks consisting of steel rail requiring elevated decks acceptable due to additional expense of deck Installation. less than 3/16"of the 3/4"x 3/4"steel insert is above ground.This track is IN-TRACK ANTI-TIP OPTION:(Recommended whenyardage/shelving height-to-depth ratio exceeds 4:1 of or in Seismic primarily used when specifications require a levelable track.The track can risk areas.)Steel anti-tip arms(attached to the inside of the carriage)travel in the track anti-tip rail as the carriage is moved —"DDTee� be grouted Into the floor or a deck can be built around the track ensuring along the track.By design,the anti-tip is riding in exact relationship to the wheel axles,always allowing the anti-tip to float C,y'A that It is completely level throug hoot the run.Th is will provide a completely free of drag or binding as It moves along the track.Installed,the track is anchored to the floor with HIM TZ anchors,and the 225 OAK is ROAD,SUITE I D5 TEL(8611783-5670 °finished°look to the overall system.This track is ideal for heavy duty carriages shelving is secured to the carriage.Can be employed on carriages up to 12'in length.The track is 5.3"wide and 0.Whigh. SOUTH WINDSOR 0i 06074 FAX:(88fi6O0)7&1-M like the mechanical-assist and electrical carriages. 2 Z-RAIL ANTI-TIP OPTION:(Recommended when carriage/shelving height-to-depth ratio exceeds 4:1 of or in Seismic risk areas.)Steel,floor mounted'Z'shaped rail provides alp under whchZRail and-tip arms(Attached to the inside of thecarr ageZ-Raffl free op travel as the ping.Inage is moved Z-Raing the track.l Bestriage beginsstorage tip,metrehe arm immesecureately engages the Z erI alprivet[upping Installed,theZ Rail is anchored to the floor and the storage units are secured to the H carriages.The vert cal height ot the 2 Rail Is l/8° COLOR Silver Aluminum with BlackTr m(Mechanical-Assist Drive Cover,Carriage Corner&Center Plates)is standard. T L!I-P6WMAOp Fbr imrx Neory-ouryMenuolSystem 5akrykatum Or ll.1O O W C) a) Nil nork,sAOAr p ontunless°therw,se stated AlltrorAiscutrosperifirlen9ths basedon theProlerf.Pippmnlagesrequireatrark under earM1 shelvin9uPd9hn LIIPtrIXHl a00 Flot TmJ Me<hankalAsslst(aaFl6ystem Sperifi<anons l.la.la •�V/—,] � u, LIT-Pa-Oao W H CO c CV Cl) 00 O) I I � W J C _J d) 0 -- Z B -- - SEES 0 � LLLL N Pipp Motile Storage Systems,Inc Pup Mobile Storage Systems.Inc l Q Cd ]966Wilson Drive ow .• 2966Wilson Drive MW 'r /•�\ WalkerIT415]4 I I I I I II'.,'.' Walker MI49534 800-134 J4JJ 809-134-J4JJ I V MOBILE STORAGE SYSTEMS INC. salez�pippmobilesom MOBILE STORAGE SYSTEMS INC. salesaoloomoblle coo LCP —on,.'Ir non fink m LP7 Flat Track Mechanical Mechanical Assist(RDF)System Specifications Rivet StyleRivet Style Shelving Specifications © I F TTB L GENERAL SPECIFICATIONS:The mobile system carriages track to increase storage ti compacting HEAVY UPRIGHT POST:Upright ostsare constructed of l4 au esteel formed into an an le formation of t-11/16"x .w sY 9 9 Y Y Pa 9P 9 9 9 cal rows and capacity a single aisle wsofs elvinthus converting fixed quick) storage mospace to meby chanical-assist storage 2-7/4':The posts are punched on 1-1/2"centers to accept differentversionsof beams. O densiryand capacity is gained.Rows of shelving ono carriage are quicklyand easily movedviaamechanlcal-assist drive and handle to allow access to a desired row. ANGLE UPRIGHT POST:Angle upright posts are constructed of 14 gauge steel farmed Into an angle formation of 1- 48"xt s 15/32"x1-15/32'The postsarepunched on 1 -1/2"centers with keyhole slots to accept rivetsin beams. NEW MOBILE STORAGE Non-welded own FLAT TRACK MECHANICAL ASSIST CARRIAGES: unitized carriage frames of front and rear anodized 6063- li$ T53-3/8"x2"aluminum angles with powder coated steel corner or center plates and rubber bump cushions joined by "T"UPRIGHT POST:"T"upright posts are constructed of 16 gauge steel formed into a"T"formation with a 5/16"1avity SYSTEM PROVIDED BY 48xts D four self-tapping 10-32x 1-1/2"machine Screws to end and intermediate anodized 6063-t53-7/32"x1-7/8°extruded between two Etwsof post to allow two beams to be installed back-to-back.The post dimensions are 3-11/32'x1-15/16' TENANT INSTALLED BY at um1nuno channels with four patented incorporated channel embossments.Each channel shall house three,posit ioned The posts are punched on l-1/2'centers with key hole slots to accept rivets in beams. G.C.PER MFG I 48xts- D O N under each shelving upright post or back-to-back posts,load bearing 3-1/2'diameter double-flanged 1018 carbon steel INSTRUCTIONS U wheels.Channels are drilled with computerized axle drilling at all wheel locations to guarantee precision.Case hardened LEFTTO RIGHT&FRONTTO BACK DOUBLE RIVET BEAM:The left to right and front to back double rivet beams are D I 4e"xt s- steeldrivewheelsaremountedintothechannelviahigh-speed roller conveyor flange ball bearing assemblies and idler constructed of 14 gauge steel formed into and angle formation with one leg 2-3/4°and the other leg)'The beam has D rolling wheels mounted via lubricated and sealed ball bearing race with 3/16'sideways movement with both having two shoulder rivets on each end at 1-1/2"centers to fit the key hole slots in the upright posts. 4e'xt r precision machined steel axles.Drive wheel in each carriage channel is attached to drive box sprocket,full length,via 1"diameter.096 wall steel tubes nut and bolted with'/4-20 x 1-1/4"hex head bolt and%-20 nylock nut through axle LOW PROFILE DOUBLE RIVET SHELF SUPPORT:Low profile double rivet shelf support is formed of 14 gauge steel for shafts.For ease of transportation and handling,carriages longer than 192"will be shipped In left and right halves with norm filing and ll gauge steel for heavy applications.Supports haveflatears at either end and form into a channel with NB"xis" STORE NUMBER on factory prepared lap splice per carriage.Splice will cons!st of 8'A-20 x 3/4"round head machine screws,washers and a dTom of 1-11W.. D rA 20 nuts to attach 6063-T5 3/3/8"x 2"x 12"aluminum splice angle.Height from floor to top of carriage angle(shelving `. 4s'x15' mounting surface)shall not be more than 4-5/16". FRONT TO BACK SHELF DECK SUPPORT:The front to back shelf deck supports are constructed of 14 gauge steel O I 13 69 farmed to fit from front to back between two left to right or front to back double rivet beams.The front to back shelf deck FLAT TRACK MECHANICAL-ASSIST DRIVES:The carriage will have mechanically assisted 16--1 ratio drive system which supports give the shelf Intermediate support. drives wheels In the carriage channels the full length of the carnage to eliminate"lag".The carriage will have a low profile, protruding no more than 5-1/2,drive box of 12-gauge galvanized steel that attaches to the carriage via two Vz"nylock PARTICLEBOARD DECKING:The particleboard decking is 5/8"medium density(45#)industrial grade.The decking is to ISSUE nuts to factory installed bolts and have a durable 1/8'thick ABS with haircell texture black cover to house the drive be installed with out the use of nuts or bolts. E system.An ergonomically designed single prong handle molded of industrial strength polymer,colored black with a 4a"xis" 'A'—ISSUE:PRELIMINARY mate grain finish creates earycarriage movement The handle assembyincludes alarge'decent"to pull for releasing FINISH:All steel parts are thoroughlycleaned Ina multistage washer.And'mtegral part of this stage is the application of I G DATE: 4/26/22 the.carriage safety parking/locking mechanism.The Detent is spring loaded to ensure the carriage will stay locked when the phosphate coating.This results in superior paint adhesion and rust resistance.The finest grade of industrial enamels 4e°x1s' 'B'—ISSUE:ILL REVIEW/ BID SET engaged.An optional key lock shall be available and be east lyfield Installed.The drive box upper and middle sprockets a applied with electrostatic spraying equipment.This ensures complete and even coverage.Coverage is capable of DATE: 5/EVIE 6/22 will be connected bye 95link#41 roller chain and the middle and lower sprockets connected by a 87link 441 roller chain, withstanding a minimum of 250 hours salt spray chamber as well as normal resistance of a quality finish. e each with an average tensile strength of27oolbs.and arrummum ANSI strengtificil Old,Chain tensions are to be - 3SUE;PERMIT SET fuaintained by use of upper and lowerchain steeland nylon idlers which are attachedto the drive box assembly and are o0 'ATE: 6/14/22 llyadjastable.Onehandleturn/driverevolutmndnvesthecarriage,approximately 3-1/2' CITY APPROVED PLANS SSUE: FLATTRACK Standard trackconstruction is 3-1/4"wide 6063 aluminum extrusion base with%"x 3/8"1018 cold roll steel I 'ATE: wheel rolling insert to provide 3/4"wide,matched to wheel hardness,wheel-to-insert contact surfacefor strength and Fm durability.Trackshall be top of floor mounted and ADA compliant to eliminate need for deck and ramp and designed to Reviewed for Code Compliance SUE; ' carrya minimum load of 1000 tbs,per linear carriage foot.Track sectionswill have lap splices,no buttjoints nor exhibit w O ATE: mavementordeflectondaringopeationofmovablecarriage6.Trackwill be fastened to the floor through factory drilled < . PLANS MUST BE ON JOB SITE ISSUE: and countersunk hole in steel rolling insert,so screw head will be flush or below top of steel,and matching slotinthe Ou; ATE: aluminum extrusion using 3/16 x 1-3/4"flat head cement screws placed on average 16"apart.Tracks with center groove that accept a center flanged wheel are not acceptable due to the potential collection of dirt/debris in this groove nor are ¢`m�O ~a FOR ALL INSPECTIONS tracksconsistingofsteel rail requiring elevated decks acceptable due to additional expense of deck installation. I in — SHEET TITLE FLAT TRACK END STOPS:Standard trackend stop Is 1-12"diameter rubber cushion reinforced with an internal steel washer.End stop attached at each end of track run through pre-dIT led factory hole with Hilti ll V4"x 3-1/4"anchor. = MOBILE SHELVING SPECS AND PLAN Flat T/ackMachonlcalAssut ERDF)System Specifications 05.27.08 Rivet Style Shelving Specifications 08.08.00 I SCALE + L___—J I I AS NOTED E � II II SHEET NUMBER t1A I A6.1 eh#Ae w•-ro Page DATE: 4/26/22 JOB NO: 22-010 DRAWN: STAFF CHECKED: CM INSTALLATION OF MOBILE CARRIAGES (FLAT TRACK) INSTALLATION OF MOBILE CARRIAGES (FLAT TRACK) INSTALLATION OF MOBILE CARRIAGES (FLAT TRACK) PART 1 PART 2 PART 3 C N O INSTALLATION OF FIRST TRACK ANCHORING FLATTRACK PLACING CARRIAGES ON TRACK C 0 R T L A N D CAUTION: STEEL TRACK INSERT AND ALUMINUM TRACK SPLICES MUST STAGGER. M 0 R D A N NOTE: TRACK HAS BEEN PRE—ASSEMBLED AND MATCH DRILLED FOR EASE OF ASSEMBLY. A R C H IT E C T Hilt, II — HILTI SLEEVE ANCHOR Hilti II — STEP 1O STEP 01 1/4-20 X 3 1/4 1/4" X 2" 1/4-20 X 3 1/4 ASSEMBLE ONE STATIONARY UNIT AT THE END OF THE TRACK RUN WASHER WASHER 711 N. FIELDER RD. PER LAYOUT. USE STATIONARY SHELVING TO ASSIST IN ALIGNING REFER TO TRACK LAYOUT SHEET (PROVIDED WITH 3/8 x 3/4 STEEL INSERT STEP 1O ARLINGTON, TX 76012 TRACK AND MOBILE CARRIAGE. ORDER) FOR PLACEMENT OF EACH TRACK AND END STOP END STOP PH: (817) 635-5696 TRACK TYPE BEFORE STARTING INSTALLATION. ONCE FIRST TRACK IS SECURE, THE REMAINING STEP O2 TRACKS MAY BE SET INTO PLACE. USE CARRIAGES AS FAX: (817) 635-5699 LAYOUT ALL TRACKS (USE CARRIAGE TO AFFIRM TRACK SPACING BYF I A GUIDE FOR TRACK PLACEMENT. MEASURE TO ROLLING CARRIAGE ON LOOSE TRACK). THE TRACK CLOSEST TO THE STEP Q TYPH ALL DTRACK HOLE WITHOUT *TrLak ENSURE TRACKS ARE TRULY PARALLEL. WALL WILL BE NO LESS THAN CONFIRM TRACK IS PARALLEL TO THE WALL. COUNTERSINK X" FROM THE REAR EDGE OF TRACK TO THE WALL. Y ) STEP O2 LICENSED USE THE HILTI DRILL BIT q" DIA. FOR SECURING ARCHITECT NOTE: STAG ARD SPLIT JOINTS ALUM TRACKSLIDE ONE CARRIAGE ON THE TRACK TO DETERMINE AR-2096 NOTE: CONFIRM PLUMB OF BACK WALL TO ENSURE THAT ONCE TRACK. THE TRACK HAS BEEN PRE—DRILLED. START BY SPACING. VERIFY CARRIAGE WHEELS ARE CENTERED IN SHELVING IS ON CARRIAGE THERE WILL BE NO RUBBING PLACING ALL THE 96" PIECES OF ALUMINUM FOLLOWED BY THE CHANNELS AND IN THE TRACK. Xz" PACING FROM WALL ANY 73" PIECES ENDING WITH A MISC PIECE. THEN CONCRETE S B �Y STEP O3 STEP�3 VERIFY YOU WILL END UP WITH 1%2"WALL CLEARANCE ON PLACE THE STEEL IN THE ALUMINUM STARTING WITH 1 — THE TRACKS MUST BE PARALLEL AND SQUARE TO �HE TRACK RUN WHEN SYSTEM COMPLETE AND THAT 48" OF STEEL, FOLLOWED BY ALL 96" PIECES THEN THE 73" EACH OTHER TO ENSURE PROPER OPERATION. CORTLAND ORGAN ARRIAGES WILL ROLL SMOOTHLY. PIECES ENDING WITH 1 PIECE WITH A NON—COUNTERSUNK MEASURE EACH SET OF TRACKS AND THE ENTIRE STATE Of IDAHO ALIGN STEEL TO ALUMINUM TRACKSYSTEM, CORNER TO CORNER, TO VERIFY THAT EACH HOLE AT THE END. BE SURE THE HOLES IN THE STEEL USE 1/4" HILTI DRILLDISTANCE IS THE SAME. INSERT AND THE HOLES IN THE ALUMINUM TRACK LINE UP. DRILL 2 3/4 MIN DEPTH IN FLOOR USING THE TRACK AS A GUIDE, DRILL THROUGH THE STEEL STEP AND ALUMINUM IN THE FLOOR. CAREFULLY CLEAN OUT THE NOTE: HEADS OF SCREWS MUST BE BELOW RUNNINGINSTALL ALL END STOPS NEAREST THE STATIONARY PROJECT COORDINATION SHELVING AND INSTALL THE BALANCE OF THE C�,DDTech HOLE. HAMMER IN THE HILTI Y4" X2" SLEEVE ANCHORS SURFACE OF TRACK. FILE HEADS OF SCREWS IF NECESSARY CARRIAGES. SHELVING END ONLY TRACK TRACK PLACED TOUCHING AND TIGHTEN TO THE SPECIFIED TORQUE (2.2 FT—LBS MAX). TO ENSURE SMOOTH SURFACE. STEP 5 STATIONARY SHELVING 225 OAKLAND ROAD,SUN 105 m:(AeR 795-5670 TRACK HARDWARE KIT INSTALL REMAINING TRACK ANCHORS. SOUM WINDS014 Cr 06074 HAL(Reo)TRS-seep STEP O (PER RUN OF TRACK) I STEP INSTALL END STOP USING THE 3 Y4" LONG, 1/4" DIA, HILTI KB3 ANCHOR. PART DESCRIPTION Track SLIDE THE REMAINING CARRIAGES ON THE TRACK, TRACK NUMBER F7 VERIFY SMOOTH OPERATION. INSTALL THE REMAINING ONE PER EACH END OF TRACK. NOTE: 48" PIECE WILL TRA311 1/4 X 2" END STOPS. NEED TO BE DRILLED OUT TO ACCOMIDATE HILTI KB3 FASTENER. FLAT HEAD PHILLIPS WLL SLEEVE ANCHOR r NOTE: HOLE DEPTH FOR HILTI KWIK BOLT MUST BE TRA202 HILTI TZ, O N CONSISTENT TO PREVENT TRIPPING HAZARD. SEISMIC, 3/8X3 r) 00 0) " W Q 0 co co � JT 0 LL m Z Z U Q CL U 0) cry ATTACHING SHELVING TO CARRIAGES INSTALLATION OF DRIVE BOX INSTALLATION OF DRIVE BOX �N = 1. REMOVE THE COVER (FIG E) FROM THE RESPONSIVE DRIVE BOX. C 01 R� (� (� n 2. SLIDE THE RESPONSIVE DRIVE BOX USING TOP 7W0 MOUNTING HOLES OVER THE TWO }¢" — 13 BOLTS (FIGB) EXTENDING FROM THE Cd 4 "T" POST Rv� (u (U� U CENTER OF THE CARRIAGE. THESE BOLTS ARE HELD IN PLACE BY (4) JAM NUTS (FIG A) WHICH ARE LEFT IN POSITION. L" POST M 4 Q u v Q 3. WHEN THE RESPONSIVE DRIVE BOX IS SEATED AGAINST THE JAM NUTS (FIG A), INSTALL Yz INCH WASHERS (FIG C) AND TIGHTEN THE ,I• L I "L POST Q ( p� q v tn TWO Yz" — 13 NYLON NUTS (FIG D), WHICH ARE IN THE ACCESSORIES BAG. J (0 N 4 Q u UV VU 4. ATTACH CHAIN TO CHAIN IDLER. ONLY USE MASTER LINK.ASSEMBLY, TOO THE NOT BOTTOMS ROCKET ASSEMBLY (FRONT DRIVE CHANNEL) AND AROUND THE O F O p p Q 4 4 p 5. ASSEMBLE THE END—SHELVING UNIT. THIS CAN BE DONE AFTER THE RESPONSIVE DRIVE BOX ASSEMBLY HAS BEGUN. THE TYPE OF 0 8 p pv v Uq SHELVING USED WILL DETERMINE HOW THE RESPONSIVE DRIVE IS FASTENED TO THE SHELVING. STORE NUMBER CORNER PLATE 6. AT THIS TIME SECURE THE DRIVE BOX AT THE TOP, AS WELL AS THE BOTTOM. MAKE SURE THE RESPONSIVE DRIVE BOX IS SQUARE AND ~ 8 8 U 4 PARALLEL TO THE SHELVING. USING THE HARDWARE PROVIDED (2 BOLTS, 4 WASHERS,AND 2 NYLOCK NUTS) FASTEN THE DRIVE BOX TO 1369 q q - THE SHELVING. PLACE THE PROVIDED WIDE PROFILE BEAM (IF RIVET SHELVING) SO IT COVERS THE SLOTS ON THE BACK OF THE DRIVE 1 1/4" LONG v U BOX. USING A k" DRILL, DRILL 2 HOLES THROUGH THE SLOTS AND THE WIDE PROFILE BEAM. PLACE A WASHER ON THE BOLT AND RUN ' TEK SCREW 8 y IT THROUGH ONE OF THE SLOTS IN THE BACK OF THE DRIVE BOX.REPEAT FOR THE OTHER BOLT. WHEN THE UPPER SCREWS ARE SECURE U AND THE RESPONSIVE DRIVE IS PROPERLY POSITIONED, YOU MAY TIGHTEN THE TWO Yt" NUTS AT THE BOTTOM (FIG D). ISSUE 'A'—ISSUE:PRELIMINARY 3" LONG FIGURE QTY.DESCRIPTION DATE. 4/26/22 TEK SCREW 7. INSTALL THE COVER (FIG E) USING THE SIX SHEET METAL SCREWS PROVIDED (FIG F) ATTACH E—CLIP TO HANDLE SHAFT. A 4 1/2-13 NUT (INSTALLED ON CARRIAGE) 'B'—ISSUE:LL REVIEW / BID SET CENTER PLATE B 2 1/2-13 HEX BOLT(INSTALLED ON CARRIAGE) DATE: 5/6/22 1 1/SC LONG B. INSERT SQUARE KEY INTO KEY SLOT ON HANDLE SHAFT. C 2 1/2 INCH FLAT WASHER 'C'—ISSUE:PERMIT SET TEK SCREW CARRIAGE _ 3 NYLOCK NUT DATE: 6/14/22 CORNER PLATE 9. ATTACH-4" E—CLIP (FIG P) OVER SQUARE KEY IN SLOT ON SHAFT. NOTE: THE TAB ON THE INTERIOR OF E—CLIP SHOULD REST NEXT AND E 1 COVER NOT ON TOP OF SQUARE KEY, SO THAT E—CLIP SNAPS FIRMLY INTO PLACE ON SHAFT. F 6 COLOR COORDINATED S/M SCREW 'D'—ISSUE: G 2 CHAIN TENSIONER DATE: ( SCREW (1) 3"TEK SCREW THROUGH EACH CENTER PLATE 10. INSTALL (FIG N, FIG 0), DETENT LOCKING PLATE, USING TWO #-20 C' SINK SREWS. 1 1 MECHANICAL ASSIST HOUSING 'E'—ISSUE: J 1 3/16" SQUARE KEY FOR HANDLE DATE: INTO "T" UPRIGHT POSTS K 1 HANDLE ASSEMBLY L 1 3/4 INCH NYLOCK NUT 'F'—ISSUE: X"11. INSTALL THE HANDLE (FIG K) USING THE 3/16" X 3/16" X " SQUARE KEY (FIG J). INSTALL THE 1-1/16"JAM NUT (FIG Q. TIGHTEN DATE: THE JAM NUT (FIG L) WITH THE 1-1/16 ( SCREW (1) 1 1/4"TEK SCREW THROUGH EACH CORNER PLATE THIN WALL SOCKET HANDLE IS SEATED N 1 DETENT PLUG PLATE INTO "L" UPRIGHT POSTS " 0 2 1/4-20 C'SINK SCREWS SHEET TITLE AGAINST THE E—CLIP ON THE SHAFT. INSTALL THE BLACK DOME PLUG(FIG M).NOTE:THE BLACK DOME PLUG(FIG M)IS P 1 3/4" E—CLIP PLEASE NOTE: NOT ALL UNITS WILL HAVE "T" POSTS. IF THIS IS THE CASE NOTCHED SO THAT IT WILL ONLY FIT ONE WAY INTO HANDLE. LINE UP BLACK DOME CUT AWAY WITH DETENT IN HANDLE. DO NOT DISREGARD STEP(, AND PROCEED DIRECTLY TO STEP( FORCE BLACK DOME INTO PLACE. MOBILE SHELVING INSTALLATION 12. THE RESPONSIVE DRIVE INSTALLATION IS COMPLETE AND YOU MAY NOW INSTALL THE REMAINDER OF THE SHELVING. DIAGRAMS NOTE:OBSERVE THE LOWER CHAIN ROUTING.CHAIN MAY NOT FIT PROPERLY IF ROUTED DIFFERENTLY. SCALE CITY APPROVED PLANS AS NOTED Reviewed for Code Compliance SHFET NUMBER PLANS MUST BE ON JOB SITE A6.2 FOR ALL INSPECTIONS Page DATE: 4/26/22 JOB NO: 22-010 DRAWN: STAFF CHECKED: CM TO 2966 WILSON DRIVE NV o 2966 WILSON DRIVE NW ® 2966 WIL50N DRIVE NW o 2966 WILSON DRIVE NW GRAND RAPIDS MI 4953• GRAND RAPIDS MI 49534 GRAND RAPIDS, APIDS MI 49534 GRAND RAPIDS MI 49534 I I I I'•.'•'• TEL 800.234.74T IIIIII'•,'•'• FTEL 800.234.7477 TEL:8AX: 611 .791.99 fi I IIIIII'•,'•'• FAX:6�6.79�.99 6 IIIIII'•,'•'• FAX:6�FAX: 616.791.9911 6.791.9916 WWW.PIPPMOBILE.COA WWW.PIPPMOBILE.COM WWW.PIPPMOBILE.COM WWW.PIPPMOBILE.COM MOBILE STORAGE SYSTEMS INC. E-MAIL:CUSTOMERSERVL�PIPPMOBILE.COA MOBILE STORAGE SYSTEMS INC. E-MAIL: CUSTOMERSERV@PIPPMOBILE.COM MOBILE STORAGE SYSTEMS INC. E-MAIL: CUSTOMERSERVC�PIPPMOBILE.COM MOBILE STORAGE SYSTEMS INC. E-MAIL: CUSTOMERSERV@PIPPMOSILE.COM C 0 R T L A N D CARTERS SUPPLIES A CARTERS HARDWARE WITH WOODEN BIN (HB) B CARTERS MARKETING / VISUAL SUPPLIES (MV) C CARTERS HANG UNIT (HG) D M 0 R G A N UNITS WILL BE 10'HIGH UNITS WILL BE 10'HIGH HW-HARDWARE(NON MERCH) UNITS WILL BE 10'HIGH VC-VISUAL CARTERS fi OV-VISUAL OSH GOSH(NON-MERCH' UNITS WILL BE 10'HIGH A R C H I T E C T WITH 8 SHELVES 8 OPENINGS WITH 5 SHELVES 5 OPENINGS WITH 8 SHELVES 7OPENINGS WITH 2 SHELVES 7 HANG LEVELS SHELVING UNIT PARTS: SHELVING UNIT PARTS: SHELVING UNIT PARTS: SHELVING UNIT PARTS: 711 N. FIELDER RD. OA © © OD © OF OG OA (i) 0 OD OE OF © OA © © OD © OF QG A O © 0 OD © T @ PH: (817) 635-5696 LArON F FAX: (817) 635-5699 P:oEoow LDwPSDf LE ..mG�"a �r7 >:oEoo .Ow Pao.LE LICENSED ET .B o�owN LowvaoNlE mamma,a.� Low PreDHLE °rW��"a •�°F m:a IT Q A Q Q Q EH cD�. ARCHITECT H D AR-2098 Q SUPPURT BERMS cnc C Q CH 1£VEL EH COPNER Q SUPPGRT BEAMS EACH LEVEL cx cOHNEB Q SUPPORT BEAMS EACH LEVEL 5 OPEN SLOTS Q aLEVEL 5 OPEN SLOTS Q SUPPGRT BEAMS (LN Q 9 OPEN SLOTS cOLVEL C­ULIC. Q CORTLAND NORGAN GTATF Of IOAHO UPcn LEVEL cn�EVELw IrvEL UPRIG T alE✓ELQEA f EA ;E EA UPRIG T ' EACH LEVEL E E EACH LEVEL E En Q r i Q fAtx LEVEL E ' Q 6 SLOTS r Q I GEX IEVFL D , Q Q Q 5 SLOTS SPACING DETAIL SPACING DETAIL s s ors SPACING DETAIL SPACING DETAIL PROJECT COORDINATION "NUMBER OF SLOTS SHOWN I H sl.Ors �,o,DDT��1-1 INDICATE NUMBER OF OPEN 5 SLOTS SLOTS IN BETWEEN SHELF 225 OAXUND RONX S➢RE 105 TEL(BW)7B5-s67D BEAMS0 K SWIH WINDSOR,C7 0R071 FAE( )781-5670 "ALL BEAMS/SUPPORTS "NUMBER OF SLOTS SHOWN "NUMBER OF SLOTS SHOWN TAKE 2 SLOTS INDICATE NUMBER OF OPEN B INDICATE NUMBER OF OPEN O SLOTS IN BETWEEN SHELF SLOTS IN BETWEEN SHELF BEANS "NUMBER OF SLOTS SHOWN SLOTS INDICATE NUMBER OF OPEN BEAMS "ALL BEAMS/SUPPORTS 4 S SLOTS IN BETWEEN SHELF "ALL BEAMS/SUPPORTS W r BILL OF MATERIALS: TAKE(2)SLOTS BEAMS TAKE(2)SLOTS w F F (16)DV35 LOW PROFILE SUPPGRTS 01 ' r^ Lib) V36 6 or 4e LOcWi PROFILE SO PORTS 1 BEANS SUPPORTS 3 % I SLOT (z) DA18 HIGH PROFLE SUPPORTS 21 SLOTS i E i i ` TAKE(2)SLOTS (V :; (B) PH3615 or 4815 PARTICLE BOARD SHELVES ` ^ M T HILL OF MATERIALS: BILL OF MATERIALS 5 \/, W C ,; J. HILL OF MATERIALS: ' / (16)➢V15 LOW PROFILE SUPPORTS C (4) ➢V36 or 48 LGW PROFILE SUPPORTS` CHU➢V15 LOW PROFILE Sl&PORTS C (16)➢V36 or 41 LOW PROFILE SUPPORTS (4) ➢A36 or 48 HIGH PROFILE SUPPORT C ':iI D TOP AND BOTTCNCNI c ;I �a" DR DA36 or48 H[GH PROFILE SUPPORT ° (DO ➢A15 HIGH PROFILE SUPPORTS 11 3a oraa' fIOJ DV36 or 9B LOW PROFILE SUPPORTS UO ➢A18 HIGH PROFILE SUPPORTS fU ➢A36 or 48 HIGH PROFILE SUPPORT (8) PB3615 or 4815 PARTICLE BOARD SHELVES /� (2) 36'or 48 HANG BARS rn'"oaae' m '/'� ie (2) ➢ASSIHIGH PROFILE PARTICLE SHELVES `�/ (2) PB3619 or 4819 PARTICLE BUPRU SHELVES is C \ 5) PB36 9 or 4835 PARTICLE BO y/ \�/ J J J r 0 Z Cd O 2966 WILSON DRIVE NW ® 2966 WILSON DRIVE NW ® 2966 WILSON DRIVE NW 0 2966 WILSON DRIVE NW . . . GRAND RAPIDS,MI 49534 .• . . GRAND RAPIDS,MI 49534 .• . . GRAND RAPIDS,MI 49534 UEn GRAND RAPIDS,MI 49534 IIIIII' ' TEL 616.79.7471 I IIIIII' ' TEL 616.791.9916 IIIIII' ' TEL:800.234.7477 TEL:800.234.7477 FAX:616.791.991E FAX: 616.791.CQM FAX:616.791.COM FAX:616.791.9916 WWW.PIPPMOBILE.CON WWW.PIPPMOBILE.COM WWW.PIPPMOBILE.COM wWW.PIPPMOBILE.COAA MOBILE STORAGE SYSTEMS INC. E-MAIL:CUSTOMERSERV@PIPPMOBILE.CON MOBILE STORAGE SYSTEMS INC. E-MAIL: CUSTOMERSERV@PIPPMOBILE.COM MOBILE STORAGE SYSTEMS INC. E-MAIL:CUSTOMERSERVOPIPPMOBILE.COM MOBILE CARTERS HANG UNIT PASS-THRU IL: CUSTOMERDSERV@PIPPMOBILE.COM CARTERS ACCESSORY/HANG UNITS (CA) E 11 CARTERS FOLD / ACCESSORY UNIT F GRID BACK UNIT G �N UNITS WILL BE 10'HIGH UNITS WILL BE 10'HIGH CARTERS ACCESSORIES W/HANG CA-ACCESS(CARTERS UNITS WILL BE 10'HIGH UNITS WILL BE 10'HIGH NI WITH 2 SHELVES 7 HANG LEVELS(14 Hang Bars) WITH 12 SHELVES 2 HANG LEVELS WITH 12 SHELVES 11 OPENINGS WITH 2 SHELVES C O SHELVING UNIT PARTS: SHELVING UNIT PARTS: SHELVING UNIT PARTS: SHELVING UNIT PARTS:® ® 0 ® C A 0 O O O (D O O O 0 O O T © O © 0 O T O OIP 0 MIA M T Paa� �N&EwP ® =E M.haLL �x ry A „n T 1—T �E AE— o Nry H� 1HEL-AL p L N 1T T xPaax Ra E oo xEoo E oo a Ea ET o p t D�Dx I-- xwD�e �wry Lo P�n E 0 w� EODwry OwP�A E owo�N E P P�N� ..x Q .1-OR EVEL Q F Q F O Q PsnELr ` 9 STORE NUMBER Q Q Q P.� OL Q SIiPOtT BEIIIS cx LEVEL Q SUPPORT BEAMS ncOxNER 5 DPEN SLDTS SUPPORT BEAMS CH COP.Nf n HlYI>sar:o 9 OPEN SLOTS Q nLE 5 OPEN SLOTS Q Q 1369 4 4 Q LDN:ER Q Q Q LPRI Q UPRIGHT x E UPRIGHT 1.1LE Q LEVEL $PACING DETAIL ISSUE B Q zJ O ssioTs µ INDICATE NUMBER OF MEN DATE: Q 2HANGER BARS 1 �nUMBER OF SLOTS SHOWN 'A'—ISSUE:PRELIMINARY SLOTS IN BETWEEN SHELF 4/26/22 SPACING DETAIL HIEVEI SPACING DETAIL xLEwEL SPACING DETAIL BEAMS °j= 'B'—ISSUE: LL REVIEW / BID SET i I —ALL BEAMS T wPPOR S DATE: 5/6/22 s SLOTS TARE(2)SLOTS 'C'—ISSUE:PERMIT SET "NUMBER OF SLOTS SHOWN s SLOTS DATE: 6/14/22 —NUMBER OF SLOTS SHOWN INDICATE NUMBER OF OPEN __ 'D'—ISSUE: INDICATE NUMBER OF OPEN "`NUMBER OF SLOTS SHOWN SLOTS IN BETWEEN SHELF s SLOTS I •� DATE: SLOTS IN BETWEEN SHELF INDICATE NUMBER OF OPEN BLS w Wei�II BEAMS SLOTS IN BETWEEN SHELF s S oTs 'E'—ISSUE: BEAMS ,II I ESEL "ALL BEAMS/SUPPORTSSLOTS4Ww. ,ram. DATE: "ALL BEAMS/SUPPORTS Ex E�ExL TAKE(2)SLOTS s I 'F'—ISSUE: TAKE(2)SLOTS `"ALL BEAMS/SUPPOR I SLOTS DATE: TAKE(2)SLOTS I I( L ' SHEET TITLE „w.✓' s SLOTS PILL OF MATER➢AL9 ON BILL EF MATERIALS. BILL OF MATERIALS, c Bo Lv 6 SLDTS 0 Axo e[xmm OrvLr(4) DV36 or w LOW PROFILE SUPPORTS )a'0:+^rv' C c EACHLEva <22)DV35 LDW PROFILE SUPPORTS 1 c u -" MOBILE SHELVING �4) IM36 or 48 MGM PROFILE SUPPORT (18)➢V15 LAW PROFILE SUPPORTS (22)DV36 or 4B LOW PROFILE SUPPORTS l6l M30 MR PR61LE SUPPORTS 28)➢A36 DR 4B HIGH PROFILE SUW PROFILE PPOORTS <2l OA36 or 48 HIGH PROFILE SUPPORT ... CH LEVEL �14) %•ar 43 HANG BARS (2l ➢Al5 HIGH PROFILE SUPPORTS _ 2) M36M x 48M PARTICLE HOARD SHELVES 4) ➢AS HIGH PROFILE Su Oxis (12) Al HI or R4SIEOFI PARTICLE BEARD SHELVES C ASSEMBLY DIAGRAMS (2) 36'GOR 36 HANG BARS PP 12) PB3615 DR 4813 PARTICLE BOARD SHELVES s. / \ / a SCALE CITY APPROVED PLANS AS NOTED Reviewed for Code Compliance SHEET NUMBER PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS A6.3 Page DATE: 4/26/22 JOB NO: 22-010 DRAWN: STAFF CHECKED: CM C M NOTES: C 0 R T L A N D L LIGHT DUTY STORAGE FIXTURE STORAGE GAPAGITY: w PER LEVEL 90 PROVIDE A GONTIUOUS 18 6A ANGLE N D R G A N 2.BENT STEEL PLATE ASTM ASlO FOR SHAPE Fy= 36 ALONG TOP OF SHELVING.SCREW ANGLE,000 P51 GRADE 36 TO EA 16"O.G.WALL STUD WITH•10 A R C H I T E C T 3.ALL BOLTS A50-1(UNLESS OTHERWISE NOTED). OR APPROVED EQUAL SCREWS,SCREW NGLE TO EACH WALL 4.INSTALL(1) 9"X I�"EMBED HILTI KWIK BOLT-TZ ANGHOR PER FOOT SHELF UPRIGHT WITH#10 5CREW5 PLATE,IGG #E5R-1555 711 FIELDER RD. 5.CONCRETE 4" THICK x 2500 P51. ARLINGTGN, TX 76012 ................... PH: (817) 635-5696 FAX: (817) 635-5699 0 ATTAGH P05T TO ° STOCK UNIT HEI NITOF SHELVES FOOTPLATE W/(1)EA.4,10 X 5/8"SELF LICENSED DRILLING SCREW ARCHITECT ADJU5TMENT5 AREA,2"O.G. ° u..... u TYP. ............................ 5/I6"x 5/8"SLOT ............ ................... .. 0 T GALVANIZED STEEL CORTLANO MGRGAN P05T STATF Gf I0AH0 . 5HELVLE5 2" g PROJECT COORDINATION C�,DDTeCh 2 \ ° .................... .. ° FUWPR1I6HT BE ° (8)SLOTS p o u u RE 225 OMMD RDAD,S9¢105 m:(eee6op11M-5670 WEENmunl 'n OV4 FA( "�-M x ° ° ° ° J o ° m o a) I111 z 0 U) .................................. ° ° ° o ° 2 1/4" W o .. ° W in.......................... ........ Q I/16"THK. O C M 5/16"0 HOLES � ° ° ° USE "X I/�"EMBED ` J HILTI KWIK BOLT-TZ AT L 1 ° ° F J FRONT CORNERS OF J r— o u RACK ZO J 1a ....... ................. ...... LL ......... ........................ ° y 2"MIN.EMBEDMENT U 1 \V Z Z C/d1 48" � 3.L SEE FIXTURE PLAN U00 1/4" 8 PROVIDE BENT STEEL ANGLE, v r EXPANSION BOLTED TO CONCRETE 5LAB AND SGREHED TO VERTICAL I REO'D PER FOOT PLATE SHELVING POST.(AT EACH FRONT P05T BASE TYR.SEE DETAIL) STOCK ROOM SHELVING NSTALLATION DETAL G SST$OCK ROOM SHELVNG INSTALLATION(SO ETM DETAIL) CdC tnj Q O PROVIDE A GONTIUOU5 IS 6A ANGLE ALONG TOP OF 5HELVIN6.51-REH ANGLE TO EA 18"O.G.HALL STUD WITH#10 SGREWS,5CREW NGLE TO EACH HALL SHELF I =I UPRIGHT HITH#10 5GREH5 U � O STORE NUMBER SHELVES TO 1369 BE SPACED 50(8)SLOTS . . . . IN STANDARD ___«< • ARE VISIBLE ISSUE • • • • BE 'A'—ISSUE:PRELIMINARY . . . . . . . . . . . . . . . . . . . . B1RAGKET5 DATE: 4/26/22 . . . . . . . . . . . . . . . . . . . . . . . . . , 'B'—ISSUE:LL REVIEW / BID SET • . . . . . . • • • • DATE: 5/6/22 5HELVLE5' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' 'C'—ISSUE:PERMIT SET • ' • ' " ' • ' • ' • ' • ' DATE: 6/14/22 . . . . . . . . . . . . . . . . . . 'D'—ISSUE: . . . . . . . . . . . . . . DATE: ---- E' ISSUE: DATE: 'F'—ISSUE: DATE: SHEET TITLE GALVANIZED STEEL END CHANNELS - I STOCK SHELVING ADJUSTMENTS,2"O.G.(TYPJ ,J i 48" � 48" I1. 48" I. IS' DETAILS CITY APPROVED PLANS GALVANIZED STEEL END PROVIDE BENT STEEL ANGLE,EXPANSION BOLTED TO SCALE Reviewed for Code Compliance CONCRETE SLAB AND 5GREWED TO VERTICAL 5HELVIN6 POST.(AT EACH FRONT P05T BASE TYP. AS NOTED PLANS MUST BE ON JOB SITE (SEE DETAIL) FOR ALL INSPECTIONS 3 STOCK ROOM SHELMG R'ETALLATM DETAIL �(TYPICALZSTOCK ROOM SHIM1IM PISTALLATM SHEET NUMBER GaAs NNi I etas yr-ra A6.4 Page O O O LIGHT FIXTURE SCHEDULE: DATE; 4/26/22 mm SYM MARK DESCRIPTION MFG CATALOG LAMP TYPE VOLTAGE MOUNTING TY REMARKS JOB NO: 22-010 Ir ,I RECESSED 2X4 ARCHITECTURAL 2x4 O ———————————————— ——————————————— ______________ LINEAR LED FIXTURE W/ EMERGENCY ATTAIN CART-AT-TF-24-50- 50 WATT/LED UNIV RECESSED 4 PROVIDED BY TENANT A/EM BALLAST AND 90 MINUTE BATTERY 37-A-EM 3700K INSTALLED BY G.C. DRAWN: STAFF A — — — — — — — — — BACK-UP CHECKED: DP 7 AA LED PENDANT FIXTURE SUSPENDED COLOR SPECTRUM DB1817LEDGV55L35KEX/ 40.6 WATT/LED JOUNT TENANT PROVIDED 3 Ks MATTE WHITE 120V PENDANT 43 FIXTURE MOUNT 10'INSTALLED BY G.C.B6" o N LIGHTING RDCS/HMAT60/XX/XX 3500K B1 7 B1 7 B1 7 B1 7 N m F— A.F.F. FIXTURE PROVIDED A/EM WITH 60" STEMS TO BE B1 81 15 B1 15 31 15 B1 15 B1 15 B7 15 B7 15 81 FIELD CUT o m Z xm z C 15 17 7 TRACK MOUNTED LED WALL WASHER, CON-TECH CTL181V35D-R 30 WATT LED TRACK (56) HEADS PROVIDED BY TENANT c N~N 2 7 7 �� AA AA AA Bl/X� MOUNTED IN SINGLE CIRCUIT TRACK, / 120V MOUNT (1) 49' TRK INSTALLED BY G.C. A^s o p COLOR 19 -:19STRUCTUREITE.SUSPENDED FROM UNISTRUT AND a'm (1) 28' TRK o a 0 B1 19,21 13 11 13 11 B1 13 31 (1) 20' TRK n a m 4 (1) 15' TRK ALL-THREAD TO SUSPEND m 3 m 7 gi 15 61 15 17 7 (2) 14' TRK TRACK FROM STRUCTURE. 11-13 B1 ® 11 1 (3) 10' TRK AEF A.F.F. O 10'-6" BiC 3 17 Y v 31 1 (1) 5' TRK ^ 7 7 6VLFX400035KD8- L-LL A/EM 3 3 13 B1 7 ® C 6" LED DOWNLIGHT PATHWAY 6VLEDMD 36 WATT/LED UNIV RECESSED 12 PROVIDED BY TENANT Q INSTALLED BY G.C. 17 B1 B1 81 �� F 4' LED STRIP LIGHT FIXTURE ATTAIN AT-PD-4-30-35-8-WH-N 3OW/LED UNIV SUSPENDED 5 PROVIDED BY TENANT 1 7 AA '� '�' �` 7 INSTALLED BY G.C. C 19 17 LED EDGE-UT EXIT SIGN BEST 11 13 11 13 B7 it PROVIDED BY TENANT B1 7 � ® X LIGHTING ELXTEY-I-R-C-A INCLUDED UNIV CEILING 3 INSTALLED BY G.C. � 17 B1 WITH 90 MIN BATTERY BACK-UP SS�ONAL Fq, DOUBLE HEAD EMERGENCY PROVIDED BY TENANT �� ,�pITE,, G B1 7 �� Y WITH 90 MIN BATTERY BACK-UP PATHWAY AR-2-DL INCLUDED 120V SUSPENDED 8 INSTALLED BY G.C. 7 4 17 —J EXISTING DOUBLE HEAD EMERGENCY EXISTING FIXTURE CLEAN a 8011 v EX/Y1 WITH 90 MIN BATTERY BACK-UP V.I.F. V.I.F. INCLUDED 120 SURFACE 2 AND TEST PA ATA F B1 11 ® EX X EXISTING STANDARD LED EXIT SIGN V.I.F. V.I.F. INCLUDED 120 SURFACE 2 EXISTING FIXTURE CLEAN �g2,EOF P� WITH 90 MIN BATTERY BACK-UP AND TEST J.P 17 ®$ S AUDIO SPEAKERS ---- ---- ---- ---- RECESSED 6 SUPPLIED, INSTALLED BY 06/14/2022 19 AA hii AAArA AA imis AA AA TENANT 13 PROJECT COORDINATION 11 13 11 13 REFLD-CLG-LGT-AS-IS-REV-00 Y B1 17 (ADDTuri 3 1 s I I I 1 225 OAXVND ROAD,SUITE IDS rzL IVA 783 w7n 3 EX/Y SOLIDI mRDSX CT 06174 vL1:IN 7U15680 F B1 RES 3 KEY NOTES® LL= 19 12 Y Y . TEN LLJ D LL N 17 13 13 1 1. FURNISH AND INSTALL NEW JUNCTION BOX FOR CONNECTION OF NEW TENANT SIGN AT T.G.C. LLJ O uI 19 3 3 STOREFRONT. CONTRACTOR SHALL CONNECT NEW SIGN TO CIRCUIT AS INDICATED ON PLAN I J AND ROUTE THROUGH NEW LIGHTING CONTROL PANEL. Cn N B1 2. FURNISH AND INSTALL NEW SWITCH BANK FOR CONTROL OF SALES AREA LIGHTING. SEE T.G.C. w 7� w'l SWITCH BANK DETAIL THIS SHEET AND ELECTRIC RISER DIAGRAM ON SHEET E3.0 FOR (✓/ 00 ADDITIONAL INFORMATION. SWITCHES SHALL BE CONNECTED THROUGH NEW LIGHTING CONTROL 1117 13 11 13 11 i PANEL AND BE LINE VOLTAGE ILLUMINATED TOGGLE TYPE. L-I 0 I I I I 3. CONTRACTOR SHALL CONNECT NEW EMERGENCY LIGHTING IN THIS AREA TO SAME CIRCUIT AS T.G.C. l/ I F B1 I I GENERAL LIGHTING AHEAD OF LOCAL SWITCHING IN ACCORDANCE WITH THE 2014 N.E.C. 4. FURNISH AND INSTALL NEW SWITCHES IN THIS AREA(WHERE SHOWN AND APPUCABLE): T.G.C. Q O 'V^ 17 — — — — — 1 J 4.1. SINGLE POLE SWITCH: HUBBELL,MODEL#HBL-1221. I I 4.2. 3-WAY SWITCH: HUBBELL,MODEL/HBL-1223. � J 19 PA I 4.3. OCCUPANCY SENSOR SWITCH: LEVITON, MODEL#OSSNL-IDW OR EQUAL. ___J J 4.4. LIGHTING CONTROL SWITCH: UNE VOLTAGE ILLUMINATED TOGGLE TYPE. I 3 B7 1. 11 I 4.5. COVER PLATES: HUBBELL, COLOR WHITE. z_ Q I 17 1 I O E LL I T �'^ AA hh AA AA AA PA 1 I z N I I u/ > U F/NL 81 11 13 11 13 1 1 Q G) > Q 1 1 C1 C2 LJ 17 F.I I I I 21 B1 Y Y AA 3 17 EX/Y 3 13 3 13 13 NI F STOCK S SALES (� O :19 61 LIGHTING LIGHTING LIGHTING AA AA AA AA AA W 17 3-GANG LIGHT SWITCH 11 13 11 13 11 19 +46"AFF PROVIDE PERMANENT�� I 4 I. TYPED LABELS AS SHOWN. O • I 1 I I a II j U SWITCH BANK DETAIL V 1 2 4 AA NOT TO SCALE / II F 15 STORE NUMBER 11 -- 31 1369 B17 3 19 ^A AA AA 15 B1 7 A/EM 11 13 B1 13 ISSUE C 4 7 'A'—ISSUE:PRELIMINARY B1 7 gi 15 DATE: 4/26/22 B1 'B'—ISSUE:LL REVIEW / BID SET 7 15 7 DATE: 5/6/22 9 F B1 ICI-ISSUE:PERMIT SET B1 IX v Y DATE: 6/14/22 B1 C B1 11 11 15 'D'-ISSUE: 7 19 3 3 7 DATE: 7 19 IX 15 'E'—ISSUE: Bi 3 Bi 17 B1 17 B7 g1 DATE: A/EM F'—ISSUE: 7 EX 19 F 3 3 7 5 7 DATE: I I B1C 19 4 B, I I SHEET TITLE 7 1 9 B1 17 B, 17 B1 17 B1 17 Bi 17 7 FLOOR PLAN L- 81 7 B1 7 B1 7 BI 7 -J LIGHTING 4 CITY APPROVED PLANS WORK IX 9 I � I SCALE OE — — — -- — — — — — — — — Reviewed for Code Compliance -- ---- ------- 1/4" = — 3 PLANS MUST BE ON JOB SITE L J SHEET NUMBER FOR ALL INSPECTIONS FLOOR PLAN - LIGHTING WORK El � O SCALE:1/4"=1'-0" Page O O mm SEE SHEET E FOR LOW 0 DATE: 4/26/22 21'-0" 6'-6" VOLTAGE WIRING DIAGRAMS AND I - KEY NOTES© _ I �ML' JOB N0: 22-010 ADDITIONAL INFORMATION 9 9 6'-9" 1. ELECTRICAL EQUIPMENT. SEE SHEET 0.0 FOR ABORIGINAL INFORMATION. T.G.C. IS,ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL AL DEVICES AT MANAGER'S DESK AS T.G.C. DRAWN: STAFF BELOW,SHOWN IN PLAN AND ON ELEVATION: A 2. FURNISH AND INSTALL NEW LIGHTING CONTROL PANEL SEE ELECTRIC RISER DIAGRAM AND I=AO' 18.1.ONE(1)QUAD RECEPTACLES: TWO(2)HUBBELL,MODEL/5362 IN COMMON J-BOX WIH LIGHTING CONTROL PANEL DETALS ON SHEET 00 FOR ADDITIONAL INFORMATION. CONTACT wHIIE 4 GANG COVER PUTS. CHECKED: DP G BERNSTEIN W/DISTRIBUTION AND CONTROL PRODUCTS LLC AT 617-823-8820 FOR 18.2.ONE(1)ISOLATED GROUND DUPLEX RECEPTACLE HUBBELL.MODEL JIG-5362 WIIN WHITE PURCHASING. COVIIR PLATE 19"AFF 3. ALL CIRCUITS USED TO POWER THE CASH REGISTERS SHAL NOT BE USED FOR ANY OTHER T.GC. 18.3.ONE(1)DUPLEX RECEPTACLE HUBBELL MODEL}5362 WITH WHITE COVER RATE. 18"AFT 10 _ PURPOSE. CIRCUITS SH4L NOT SHALL NENNAL OR GROUND WITH ANY OTHER EWIPMENT. 18.4.-(2)JUNCTION BOXES. p N 18.5.TWO(2)PHONE OUTLETS: HUBBELL RIPE W11 WITH WHITE COVER PLATE. N b r- 24 , SFPANTE PO ER.NEUTRAL AND ISOLATED GROUND WIRES MINIMUM SIZE/12 AWG SHN1 BE . Q N O RUN TO THE CIRCUIT BREAKER PANEL BOARD WHERE GROUND WIRE SHALL BE TIED H THE 19.FURNISH AND INSTAL 4X4 JUNCTION BOX AT 11'-0-AF.F.AND DUPLEX RECEPTAOE AT T.G.C. O GROUND TERMINAL ISOLATED FROM THE NEUTRAL. DO NOT USE CONWR FOR GROUND AS ]'�•AF.F.FOR NETWORK CABINET. SEE ELEVATIONS ON THIS SHEET FOR PDDIIIONA m Y X Z THS INY NOT BE CONTINUOUS. CASH REGISTER CIRCUIT SHALL BE RUN IN SEPANTE / CONDUIT. RECEP ACLES SHALL BE HUBBELL.MODEL/IG-5362 ORANGE. INFORMATION. o {. FURNISH AND INSTALL AN IXIRA CABLE THROUGH THE CEILING AND LEAVE IT COILED FOR T.GC. 20.FURNISH AND INSTAL QUAD RECEPTACLE AND J-BOX FLUSH MOUNTED IN WALL AT 72'A.F.F. T.C.C. N~N Z MORE USE. AW M SYSTEM WRING TO BE BY VENDOR. ROUTE 3/4'EMPTY CONKER CWITHAS PULL STRING FOR J-BOX TO BE B'CONDUIT E CEILING HALL FOR •Y O O 1O SPEAKER CABLES. SPENCER CABLES ABOVE CEMENT AND R BE IN CONDUIT OR SHALL BE ^ O a I 5. FURNISH MO INSTALL SECURITY S GROUND DUPLEX RECEPTACLE FLUSH MOUNTED VERTICAL AT T.G.C. PLENUM RATED. VERIFY SOUND SYSTEM EQUIPMENT AND REQUIREMENTS WITH SYSTEM O 10'-0'A.F.F.FOR SECUMY SYSTEM. SUPPLIER. e. FIELD VERIFY ENACT LOCATON OF EXISTING TELEPHONE SERMCE IN SPACE AID EXTEND AS T.G.C. 21.FURNISH AND INSTALL ONE(1)ISOLATED GROUND DUPLEX RECEPTACLE FOR COMPUTER T.G.C. REQUIRED FOR CONNECTION TO TENANT TELEPHONE EQUIPMENT. PROVIDE 3/4-PLYYYOOD SYSIELI AT 3'-0"AF.F. BACK FOR MOUNTING OF NEW ELECTRICAL AND TELEPHONE EQUIPMENT,SIZE AND SECURE AS REQUIRED. PROWDE ISOLATED GROUND QUAD RECEPTACLE FOR POWER TO 22.FURNISH AND INSTALL NEW JUNCTION BOX FOR PRINTER AT 3'-0'AF.F.WIIN 3/4-CONDUIT T.G.C. EX TELEPHONE EQUIPMENT. IN WALL M ABOVE CEILING. ® 9 1O 7. FURNISH AND INSTALL NEW RJ31x JACK FOR CHECKPOINT/SECURITY SYSTEM. T.G.C. 23.FURNISH AND INSTALL JUNCTION BOX AT DESK AND ROUTE 3/4'CONDUIT IN WALL TO ABOVE T.G.C. 16 25 27 29 16 CEIUNG. SEE ELEVATION AND DATA CHASE DETAL ON THIS SHEET FOR ADDITIONAL Q S. EXISTING WATER HEATER ABOVE TOILET ROOM TO REMAIN. INFORMATON. IG S S 18"AFF 9. FURNISH AND INSTALL NEW GENERA PURPOSE RECEPTACLES IN THE LOCATIONS SHOWN AM T.G.C. 24.FURNISH AND INSTALL TELEPHONE/FAX RECEPTACLE AT 72-A.F.F.FOR SOUND SYSTEM. T.G.C. 3/4"C CALLED FOR. HUBBELL MODEL/5362 NTH WHITE COVER PLATE. TO TTB S S 10.FURNISH MO INSTAL NEW RECEPTACLE ON CEILING FOR SHOW WINDOW. HUBBELL MODEL T.G.C. 25/5362 WITH WHITE COVER PLAC�,EPRADLE FOR MICROWAVE AT 38-AF.F. HUBBELL MODEL T.G.C. #5362 WTH WHITE COVER PLATE EX \ 28.FURNISH AND INSRPII NEW RECEPTACLE FOR REFRIGERATOR AT 15'1­ HUBBELL/5362 T.O.C. 11.FURNISH 21 INSTAL NEW SECURTIY ALARM PANEL IN-1ROOM NEAR T.T.B. RAOIONICS. VENDOR WITH WHITE COVER PLATE i6 To4� T YODEL/] zc. 2].FURNISH AND INSTALL NEW CEILING MOUNTED JUNCTION 90%FOR-TECH MONITOR. T.C.C. 12.FURNISH MO INSTAL NEW SECURITY AARY KEY PAD NM FflONT DOOR. RADIONICS. VENDOR COORDINATE BE INS NA WITH VE N NDOR. PROVIDE 10'WHIP ABOVE CEIUNG FOR JUNCTION YO NA RAY M, 6 BOX. MONITOR BE RELOCA LTED O DIFFERENT LOCATION. gS FV 13.FURNISH MO INSTAL NEW DOOR CONTACT ON O FRONT DOORS,REAR DOOR MO STOCK ROOM VENDOR F� �p\STEg4, G� DOOR. SENiROL MODEL/1082. (FIVE(5)TOTAL) 2B.FURNISH AND INSTAL AROMATIC DOOR OPENER SYSTEM S IN E.C.SO BELOW: T.C.C. O Q 28.1.PUSH PLATE SWITCHES: MS SEDCO,MODEL PUSH P1HSS. E.C.SHAD ROUTE LOW d Fp / 19 2S 26 14.FURNISH MO INSTALL NEW MOTION DETECTOR NEAR L)FROM DOOR AND IN STOCK ROOM NEM VENDOR VOLTAGE HIRING FROM DOOR OPERATOR TO PUSH PLATES THROUGH DOOR Y#810 8011 - _,2_ - REM DOOR. MODEL ADS-938Z. (TYNG(2)TOTAL) 28.2.AI'TOSHAL SWING DOOR OPERATORS. RELOAD-USA SERIES CONNECTION MODEL AUTOMATIC (RHR). S - - EC.SHALL FURNISH MO INSTALL POWER AND MME FINAL CONNECTION TO AUROMMC 15.FURNISH MO INSTALL NEW SIREN ABOVE CASH DESK AREA SIREN SHALL BE INCLUDED WITH VENDOR DOOR OPERATOR PER MMUFACNRERS REQUIREMENTS AND RECOMMENDATIONS. (120 10 PANEL�� VOLT,1 PHASE,60 HZ,67 WATTS NORMA PoWER AND 2.9 AMPS PEAK POWER) 'PT 10 40,42 1G FURNISH AND INSTALL THE FOLLOWING SERMCE BUZZER SYSTEM IN LOCATIONS CALLED FOR T.G.C. 29.FURNISH AND INSTALL NEW HANG DRYER IN LOCATION SHOWN AND CALLED FOR. THINAR T.G.C. OF P AND INDIGATEO ON SHEET E3.0: HAND DRYER,MODEL fTA-MS-120,120 VOLT,7.9 AMP,60 HZ. J.P 18.1.EDWARDS#620 PUSHBUTTON W/147-1 PLATE MOUNTED AT{8-AFF ON OUTSIDE OF REM TO BUZZER AT 12 DOOR' W.EXISTING DISCONNECT SWITCH ON THE ROOF TO REIJAN. CASH DESK _ 16.2.EDWARDS#88-50 TRMSPORMER MOUNTED ABOVE MAAGER'S OFFICE DOOR. 06/14/2022 1 16.3.EOWMOS j340A-G5 BELL MOUNTED MOVE MANAGER'S OFFICE DOOR. 31.IXISTIro AR CURTAIN TO REMAIN. 2 16.4.0WAA05#340A-GS BELL MOUNTED ABOVE CEILING AT CASH DESK. 32.EXISTING BUILDING llECRRICAL SERJICE TO REMAIN. SEE SHEER E3.0 MR PDDIIIONA 17.FURNISH MO INSTALL NEW PMIC BUTTON UNDER MANGER'S DESK. SENIROL MODEL/3040. VENDOR INFORANTON. 5 r. 33.FURNISH AND INSTALL 4X4 JUNCTION BOX AND DUPLEX RECEPTACLE AT S-W A.F.F. T.G.C. PROJECT COORDINATION 3 6 IG I 1 I 2a I CADDR(h 18-20 EX. 225 OAVND ROAD,SUIT ID5 TEL:(BW1 783-5670 3 5 IG 4 7 11 EX�RTU-1 -----, S WIN wl�CT asm4 FA:(6s0)7RE-ssm 32 l13 IN STUB-OUT cadour I TO MANAGER'S H LLI 0 LL I I OFFICE f-G 1'-0• J2*"- SNDUIT IN WAIL �w 0 (n S TL-'�1'-5"-�I -I6'I- 19TUBBED GUT AS 30 L--- ---J 14 I 13 �� I�IIIINU) �CAT-5 LABELING W1TH s/4'corouIT IN WALLWQWHIP TO DATA OUTLET ro ABDJE cEluec � � 1 ' �AT OFFICE REGISTER N L� 21 I TO ABOVE CEIi�NiGW� � LL \ S S - 2'CONWR IN WAIL Q/''� O �L © 6 1 �TO ABOVE CEIUNG •I IL J VT J V I (TYPICAL)WIRE I I / J 20 / z- Q �y1� ��- � (- 1 •i (2�2}��� ST Ir •I � Q� u 1 a > QCn > Q 32 S 0� � II I 0 0 I I � - II I I EX RTU-2EX 321 MANAGER'S OFFICE ELEVATIONS (�,�1 SCALE:3/8"=1'0" -s m 0 O I I I `-' z------ I I I =1 =I 3 ii L. 4A -- O (a O U -� - - - - - - 13r -� N / •� MMMRRE NUMBER SPEAKER S n 7 F- -- I (TYPICAL) S -V J 9 I � � I I 24 I ® I I EX \ ISSUE 'A'-ISSUE:PRELIMINARY EX® 22 DATE: 4/26/22 16 /2\ 'B'-ISSUE:LL REVIEW / BID SET 10 E�f2.0 DATE: 5/6/22 EX 18"AFF 9 E2.0 C'-ISSUE:PERMIT SET 22 E20 DATE: 6/14/22 SEE CASH DESK DETAIL _ \ 'D'-ISSUE: EXOD SHEET E4.0 FOR WIRING \ DATE: 16 INFORMATION IN THIS AREA. ® \ I � 'E'-ISSUE: DATE: 'F'-ISSUE: DATE: I � EX SHEET T11LE 22 38 --- FLOOR PLAN - u 5 2fi 10 _j 13 a"AFF a"AFF CITY APPROVED PLANS ELECTRICAL WORK O - 29 - - -- - - - - _- - - r - Reviewed for Code Compliance SCALE E -Eel s 9 s-10 �,D PLANS MUST BE ON JOB SITE 1/4" = 11-0" FOR ALL INSPECTIONS SHEET NUMBER FLOOR PLAN - ELECTRICAL WORK ELEVATIONS KEY PLAN E2. 0 SCALE:1/4"=1'-0" SCALE:1/2"=1'-0" Page PANEL DIRECTORIES DATE: 4/26/22 JOB NO: 22-010 PANEL EX. PANEL TO REMAIN LUGS EX. 225 AMP 120/208 voLr 3 PHASE 4 WIRE MAIN BREAKER Ex. M-L-o DRAWN: STAFF CKT. BKR BKR CKT. O o CHECKED: DP USE NO. LOAD SIZE A B C SIZE LOAD NO. USE uc�.-.-.-.�laD C3 SIGN 1 1200 20/1 20/1 1000 2 CASH REGISTER *LC -- H�o-__ j--ANAg-tay,m±_-- IXMDNC CONRNIL PONFL �N C3 3 1200 1000 4 *LC wrNRD.EwWrx TC2 C3 OSHKOSH SIGN 5 1200 360 6 CASH DESK RECPT. x�aW�Wvxa Hx ° o RDW WwWDD -+--¢� >--f R"g ------------ e m D w N Z C3 SHOW WINDOW LTS. 7 1056 540 8 BACKWRAP RECPT. o,i, a C3 DOOR OPENER 9 348 180 10 IT CABINET *LC z ��Y a o SALES AREA LTS. 11 894 400 12 BUZZER SYSTEMC2 13 853 400 14 TRAFFIC COUNTER *LCTC1tC1 C1 SALES AREA TRACK 15 480 720 16 EX. SHOW WINDOW RECPT. � I C2 17 660 360 18 T.T.B. RECPT. :Ix61uDRwws xc aNaaaE STOCK ROOM LTS. 19 410 180 20 SECURITY SYSTEM *LC III *LC NIGHT LTS. 21 30 540 22 EX. RR/EWC RECPT. °w Q U *LC LCP 23 400 1260 24 GENERAL RECPT. *LC MANAGER'S DESK IG 25 500 1260 26 NEW SHOW WINDOW RECPT. MANAGER'S DESK RECPT. 27 180 500 28 EX. AIR CURTIAN Oa8 SOUND SYSTEM 29 360 - 30 SPARE -r 31 4683 60/3 360 32 EX. RTU RECPT. �I uDmm xumr �<c`'VONAkF�G EX. RTU-1 33 4683 1500 34 EX. WATER HEATER rx.WxD.� 35 4683 948 36 HAND DRYER e n ✓;a11 v 37 6124 60/3 948 38 HAND DRYER L °J EX. RTU-2 39 6124 1200 40 MICROWAVE a • �q>FOF W� 41 6124 660 42 REFRIGERATOR J.P "*LC" INDICATES PANEL LOCKS PHASE A: 19514 WATTS BALANCE: 6.17% • mmnL� u« 06/14/2022 TC#" INDICATES TIME CLOCK PHASE B: 18685 WATTS % "C#" INDICATES CONTACTOR PHASE C: 18309 WATTS "R TOTAL: 56508 WATTS xo.xrsraa osena xo PROJECT COORDINATION CARnR'3/OSHxOSH-STORE N3369 �� TWIN FALLS,10 x ° D�eDa CADDTech 225 ON(LAND ROAD,SUITE 105 TEL(861 783-5670 SOUTH WIINDSOR,CT 06074 FAX:(86�)783-5680 I _ W x 0 m°�nvA�u x pxll9 wme'a0° W O PANEL/SPACE FEEDER ' D6 �x air _ _I__�,>�6�6,��NxN�x�„--- -_-_---b--Ili-o---_L-�=��---------- cn LCL INPUT FACTOR VA --1-H.2 `��' J- --FA6Na m��rD rxa�6x1--- j L6-A Ra xww�R menm----- N =------------ --+-----=o---K =------------- CO - si na e,general lighting,cash register,etc. 7787 1.25 9734 i i _ show-window or entry lighting at show-window 0 1.25 0 1MO 1P"'FN•"s"`a"Re1 W 0 'track lighting 142 75.00 1065o `track lighting show-wintlow 48 75.00 3600 x \ a.c.equipment rtu,ahu,cu,etc.-480 volt 0 831.36 D ; a�6xx� N3N�RDa�E CITY APPROVED PLANS "a.c.equipment rtu ahu cu etc.-208volt 90 360.26 32423 exxaxRmx �q Q U) r0 ° ®i N aaD Sub Total ssao7 Reviewed for Code Compliance J O� ®x0 J _ NON LCL I PLANS MUST BE ON JOB SITE �A S 3 Q Water heater,unit heater,sensonnatic traffic counter,mist.,etc. 7804 1 7804 FOR ALL INSPECTIONS receptacles 6300 6300 E >- Q� show Window lighting requirement in feeder only) 0 0 Ln O Sub Total 14104 _ /Q Q TOTAL 70511 m6.wD muxrl m min 480 volt-total amperage e auls 84.8 208 volt-total amperage e aula 195.7 • • • xntr n `N q °.o wx6a nwxN x6x I Y �J � zoran Track lighting calculated per 2014 NEC Article 220.43(B) "MCA used includes 125%of largest motor per 20014 NEC Article 220.18(A) _1°�"max 12 1 O Receptacles calculated per 2014 NEC Article 220.44 tat 10 kva Q 100%,All other Q 50% w1 sn 1 1 1 1 1 3 4 4 4 S 5 6 6 6 6 n x x N N Show-Window lighting calculated per 2014 NEC Article 220.43(A) 200 VA per LF of show-window minus actual lighting installetlNE of er'wM1°a," i 9 Cl I 7 L =I 11,13,15,17 TC1 I rasiERs/osxxosx I C2 O 'y WxWW STORFWl369-TWIN FALLS ID 1,3,5,7 I 10 TC2 C3 14 i U O I I CT- 11 15 STORE NUMBER `--------1 1369 KEY NOTES ® RES ONGIBILI SYMBOLS AND ABBREVIATIONS "°`°R° T.G.C.=TENANT G.C. ISSUE 1. EXISTING 120/208 VOLT, 3 PHASE, 4 WIRE, 400 AMP SERVICE TO BUILDING TO REMAIN. 8 'A'-ISSUE:PRELIMINARY DATE: 4/26/22 TYPE 2. EXISTING WIREWAY TO REMAIN. SWITCH OCKT RECESSED INCANDESCENT FIXTURE ,�Q,, PUSHBUTTON 'B'-ISSUE: ILL REVIEW / BID SET LJ BUZZER 3. EXISTING METER TO REMAIN. DATE: 5/6/22 SINGLE POLE SWITCH 'C'-ISSUE: PERMIT SET �-H 4. EXISTING 200 AMP MAIN DISCONNECT SWITCH TO REMAIN. 225/MLO � � DATE: 6/14/22 0 DUPLEX WALL RECEPTACLE O TRANSFORMER 5. EXISTING 120/208 VOLT, 3 PHASE, 4 WIRE, 200 AMP SERVICE TO SPACE TO REMAIN. O I 'D'-ISSUE: G MCA MINIMUM CIRCUIT AMP 1co O7 DATE: QUADRAPLEX ISOLATED GROUND RECEPTACLE 6. EXISTING 120/208 VOLT, 3 PHASE, 4 WIRE, 225 AMP PANEL WITH MAIN LUG ONLY TO REMAIN. 2 6 I GFI MOCP MAXIMUM OVERCURRENT PROTECTION I I DATE: >� GROUND FAULT QUADRAPLEX WALL RECEPTACLE 7. FURNISH AND INSTALL NEW LIGHTING CONTROL PANEL. THIS SYSTEM REPLACES MULTIPLE TIME T.G.C. 3 M 4 11 1 DATE: CLOCKS AND CONTACTORS, CONTACT GARY BERNSTEIN W/DISTRIBUTION AND CONTROL PRODUCTS zoo `--J LLC AT 617-823-8620 FOR PURCHASING. 'F'-ISSUE: >� QUADRAPLEX WALL RECEPTACLE S- -S CONDUIT ABOVE FLOOR DATE: 8. NEW LIGHTING CONTROL SWITCH BANK WITH LINE VOLTAGE LIGHTED TOGGLE SWITCHES POINT OF T.G.C. WP � CONDUIT BELOW FLOOR MARKS INDICATE NUMBER OF WIRES CONTROL FOR UNIFORM REDUCTION IN LIGHTING. COORDINATE INSTALLATION OF SWITCHES WITH WEATHERPROOF RECEPTACLE GARY BERNSTEIN W/DISTRIBUTION AND CONTROL PRODUCTS, LLC. SEE LIGHT FIXTURE SCHEDULE 1 SHEET TITLE HOME RUN CONDUIT FOR AREA OF RESPONSIBILITY. ELECTRICAL JUNCTION BOX 9. NEW TIME CLOCK #1 FOR CONTROL OF SALES AREA LIGHTING FOR AUTOMATIC SHUT OFF IN T.G.C. GRADE EX EXISTING TO REMAIN ACCORDANCE WITH THE 2018 IECC INTEGRAL TO NEW LIGHTING CONTROL PANEL. DETAILS Q TELEPHONE OUTLET SHTR SHOPPERTRACK D DATA 10.NEW TIME CLOCK #2 FOR CONTROL OF SIGNS, SHOW WINDOW LIGHTS AND DOOR OPENER T.G.C. 5 TELEPHONE/DATA OUTLET INTEGRAL TO NEW LIGHTING CONTROL PANEL. T TELEPHONE RISER DIAGRAM NOTES DATA OUTLET OC OCCUPANCY SWITCH SCALE 11,NEW 1-HOUR OVERRIDE SWITCH INTEGRAL TO NEW LIGHTING CONTROL PANEL, T.G.C. 1. CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT ICI AS (VOTED 12.POWER AND TIME CLOCK CONTROL WIRING TO AND FROM PANEL. T.G.C. BREAKER AND ALL BRANCH DEVICES AS REQUIRED. �--T4 TELEPHONE CONDUIT Q SECURITY KEY PAD 13.NEW CONTACTOR#1 INTEGRAL TO THE LIGHTING CONTROL PANEL. T.G.C. 2 CONRACTOR TOENCES R MAINTAINRTICLE ALL 0REQUIRED T.T.B. TELEPHONE TERMINAL BOARD © DOOR CONTACT NEC SHEET NUMBER 14.NEW CONTACTOR#2 INTEGRAL TO THE LIGHTING CONTROL PANEL. T.G.C.SMOKE DETECTOR OM (� r r� O MOTION DETECTOR 15.NEW CONTACTOR#3 INTEGRAL TO THE LIGHTING CONTROL PANEL. T.G.C. ELECTRIC RISER DIAGRAM 3 O D Q SIREN NOT TO SCALE Page 3 DATE: 4/26/22 -010 CASHWRAP ELECTRICAL WORK NOTES - GENERAL JOB DRAWNN:: STAFF MANAGER'S OFFICE 1.THE ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH THE LANDLORD'S CHECKED: DP REQUIREMENTS. RJ45 JACK OFFICE REGISTER AREA 2. ELECTRICAL WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED,SHOWN OR REASONABLY IMPLIED ON Po Pa (TYPICAL FOR DATA 6zmrswx a lux WL7bE DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR o�' OFFICE REGISTER SHOPPERTRACK �N U STORE FRONT ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT,WHEN SUCH ADJUSTMENTS ARE d^ o CONNECTIONS) mNN rzD Nm xw _ aaca wwcTx.wD MmooR NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. In y POS 28 P083B 3. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING m::x m z I� A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE �•5 x N wa 411114�I (4) CAT 5 IN TO MAKE THIS VISIT. o q ❑ 4. ELECTRICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE O ro o O 3/4" CONDUIT POS 2A POS 3A L2 CIRCUIT JUNCTION BOX JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. o a o CAT 5 IN 3/4" CONDUIT AT 5.CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF p a m THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY. AT NO TIME SHALL ANY WORK BE n Tn 3 STOREFRONT UNDERTAKEN WHICH SHALL INTERFERE WITH THE NORMAL OPERATION OF BUSINESS. ANY SHUTDOWN MUST REpSRN 2 REGISTER 3 P^PI�B 9HO�j�^SS T� WITH CAT 5 OCCUR AFTER REGULAR BUSINESS HOURS AND MUST BE CLEARED WITH THE MANAGEMENT WITH PROPER Ili$O-lll IIYp-�11I 111p-Jll llip-YII WHIP PRIOR NOTICE GIVEN TO THE OWNER'S REPRESENTATIVE. 6.CONTRACTOR SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER OF ERRORS,OMISSIONS OR DISCREPANCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK,OR,FAILING SUCH NOTICE, !"Y Tmricr M.xcm No waw SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT,ARCHITECT OR ENGINEER. LL 7.ORDER EQUIPMENT ON A TIMELY BASIS(WITHIN 5 DAYS OF RECEIPT OF CONTRACT)TO MAINTAIN CONSTRUCTION SCHEDULE. �J 8.SUBMIT FIVE(5)COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE MANAGER'S DESK AREA ENGINEER/ARCHITECT. ONE(1)COPIES WILL BE RETAINED FOR RECORD. ONLY FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. SOUND SYSTEM 9.WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS,WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 10.WORK SHALL ALSO INCLUDE FULL ONE(1)YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR STONALF ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. Q°' NSTE �G 11.ALL WIRE SHALL BE COPPER. MINIMUM SIZE#12 AWG. ALL CONDUCTORS #10 AND SMALLER SHALL p� p�6 RFo 2 NNE Pro 2 PINE Pin 3 LINE 1 HAVE TYPE"ITHHW"INSULATION. CONDUCTORS LARGER THAN #10 SHALL HAVE TYPE"THHN"INSULATION. a Fp I--I 12.ALL WIRE SHALL BE IN CONDUIT AND SHALL BE CONCEALED FROM VIEW. EXPOSED CONDUIT SHALL BE wi 1��11 INSTALLED IN STRAIGHT LINES PARALLEL WITH OR PERPENDICULAR TO COLUMN LINES OR BEAMS AND SHALL SOUND 13E SEPERATED BY AT LEAST 3"INCHES FROM DOMESTIC WATER LINES WHENEVER ALONG SIDE OR ACROSS SUCH LINES. ROMEX IS NOT PERMITTED. FLEXIBLE CONDUIT OR TYPE MC CABLE MAY BE USED FOR sTgTEOF P� FIXTURE AND EQUIPMENT CONNECTIONS ONLY,AND WHERE SO USED SHALL BE GROUNDED WITH A SEPERATE FULL SIZED GREEN GROUNDING CONDUCTOR. FLEXIBLE CONDUIT CONNECTIONS SHALL BE J.P a.am n10X.w LIMITED TO 3'-0"IN LENGTH. CONDUIT EXPOSED TO WEATHER SHALL BE RIGID. ALL OTHER CONDUIT f0R 40G110Nf SHALL BE EMT. CONDUIT FITTINGS SHALL BE COMPRESSION OR THREADED TYPE,USE OF SET SCREW BACKWRAP FITTINGS IS NOT ACCEPTABLE. 06/14/2022 13.CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT IN UNFINISHED AREAS MAY BE EXPOSED. 14. HOME RUNS OVER 100' IN LENGTH SHALL BE#10 WIRE. nox 15.CONTRACTOR SHALL ENSURE THAT ENTIRE INSTALLATION IN ACCORDANCE WITH N.E.C.ARTICLE 110-26 PROJECT COORDINATION rax�.ru1 AND THAT ALL REQUIRED OPERATING AND MAINTENANCE CLEARANCES ARE MAINTAINED AND ACCOUNTED FOR. C�,DDT 1 \� ADJUSTMENTS TO LAYOUT SHOWN TO ACCOMMODATE CLEARANCE REQUIREMENTS SHALL BE DISCUSSED WITH LINE ARCHITECT AND/OR ENGINEER SO AS TO MINIMIZE IMPACT ON OTHER SYSTEMS. CONTACT ARCHITECT LINEAND/OR ENGINEER FOR DISPOSITION. 16. CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN 225 OAXVND Row,SUITE IDS TEL(ew1 783-w7n '� I4^III urlE 2 CIRCUIT BREAKER AND BRANCH DEVICES AS REQUIRED. SOVIN MNMK CT 06D74 FAX:( 1)71I.1-5680 IEIIDHOHE 17.SEAL ALL PENETRATIONS THROUGH WALLS,CEILINGS,FLOORS, ETC.SO THAT THEY ARE AIR,WATER AND 1ELEexoxE II41-$6fll FIRE TIGHT. 18. PROVIDE ENGRAVED BAKELITE NAMEPLATES FOR ALL ELECTRICAL SERVICE EQUIPMENT INCLUDING FAz DISCONNECT SWITCHES, PANELS, PUSHBUTTONS AND STARTERS. LLI !� 19 SUITABLE FLIGHTINOR SWITCHINGSERVICEITS WHICH ARE . AT PANELS SHALL BE FITTED WITH TYPE"SWD"BREAKERS I__w T�r0 20. FURNISH AND INSTALL TYPEWRITTEN PANEL DIRECTORY(IES). IDENTIFY AND LABEL ALL ELECTRICAL V/Q:L T J TELCO DEMARK SERVICE EQUIPMENT. FURNISH AND INSTALL AN ENGRAVED NAMEPLATE ON THE WALL ABOVE THE SINGLE nI RECEPTACLE IN THE REAR AREA FOR HANDHELD STEAMER IDENTIFYING IT AS SUCH. W 21. FURNISH TWO(2)COPIES OF THE ELECTRIC RISER DIAGRAM AND PANEL DIRECTORY(IES)TO THE >() DO TENANT FOR REVIEW AND APPROVAL,OR SUBMIT A LETTER TO THE TENANT CONFIRMING THAT THE SYSTEM WAS INSTALLED AS PER PLANS AND SPECIFICATIONS. 22. FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. L_LJ Q 23. FURNISH AND INSTALL PANEL LOCKS WHERE SHOWN ON THE DRAWINGS. 24.WIRE EMERGENCY BALLAST AND BATTERY LIGHTS ON SAME CIRCUIT IN AREA AND AHEAD OF LOCAL N 1/ - SWITCHING O . LL LINE 1 25. EXTERIOR SIGNAGE WILL BE FURNISHED AND INSTALLED BY SIGN CONTRACTOR. CONNECT TO SIGNS. Q AND PROVIDE POWER AS REQUIRED FOR A COMPLETE INSTALLATION COORDINATE THIS PORTION OF THE CAT 5 IN 3/4" CONDUIT WORK WITH THE SIGN CONTRACTOR AND LANDLORD AS REQUIRED. 7� 26.ALL LIGHTING FIXTURES WILL BE FURNISHED BY THE OWNER. PROCURE ALL LIGHTING FIXTURES FROM a_ _J LINE 2 CITY APPROVED PLANS OWNER AND INSTALL THEM IN THE LOCATIONS SHOWN AS REQUIRED. CONTACT THE OWNER'S _j J O7 REPRESENTATIVE PRIOR TO SUBMITTING A PROPOSAL TO DETERMINE WHICH FIXTURES(IF ANY)ARE NOT FURNISHED BY THE OWNER. INSTALL ALL FIXTURES(OWNER FURNISHED AND CONTRACTOR FURNISHED)AS `� DIAL Reviewed or Code Compliance REQUIRED FOR A COMPLETE INSTALLATION. LEAVE PROTECTIVE COVERING/FILM IN PLACE ON FIXTURES O I� L__ CAT 5 IN 3/4" CONDUIT BACKUP f P UNTIL FINAL CLEAN-UP. INSTALL LIGHTING FIXTURES IN RATED CEILING SO AS TO MAINTAIN INTEGRITY OF RATING. REPLACE ANY LAMPS THAT HAVE EXPIRED DURING CONSTRUCTION AND MAKE ALL ADJUSTMENTS Q� PLANS MUST BE ON JOB SITE TO FIXTURES FOR DIRECTION AS REQUIRED PRIOR TO COMPLETION. 7 27.SWITCHES,NOT 28. RECEPTACLES AND TM EEPHONNERWISE ELOUDTL S IN�SALES AREA SHLL BE ALL 4BE MOUNTED AT8"A.F.F. UNLESSN Z FOR ALL INSPECTIONS 29.ALL COVERPLAESCLES AND FOR ALL DEVICES SHALL BE AS RRSHALL BE AS EQUIREDDTO MATCH ADJACENT IN THE TI FINISHES - �<1 COORDINATE WITH ARCHITECT. 30.VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH AND INSTALL OUTLET BOXES,DEVICES,COVERPLATES AND FLANGES AS REQUIRED. RE ED. CIRCUIT 31. IG AND GET CEPTACLES SHALL BE RATED AT 20 AMPERES AND SHALL HAVE A DEDICATED INSULATED GREEN GROUND WIRE,THE GROUND WIRE SHALL BE RUN CONTINUOUS AND UNSPUCED BETWEEN THE CAT 5 IN 3/4" CONDUIT DEVICE AND THE PANEL GROUND BUS. 32. MOUNTING HEIGHTS OF EQUIPMENT NOT SPECIFICALLY CALLED FOR ARE NOTED ON ARCHITECTURAL ` I SCHEMATIC LAYOUT OF 31X DRAWINGS- SEE ARCHITECTURAL DRAWINGS TO COORDINATE. 33.SUPPORT ALL FIXTURES ACROSS CEILING TEES OR FROM STRUCTURE ABOVE. IN NO CASE SHALL RJ- LOW VOLTAGE INTERFACES FOR CEILING TILES OR PLASTER CEILING SUPPORT ANY FIXTURES. ALARM 34.SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF CEILING GRID, LIGHT FIXTURES, ETC.AND O NOT TO SCALE NOT LIST, FIXTURE SCHEDULE,NOES AND OTHER SPECIFICATION REQUIREMENTS. 0 35.THE OWNER WILL FURNISH AND INSTALL A COMPUTER SYSTEM (CASH REGISTERS AND COMPUTERS) FOR THE SPACE. CONTRACTOR SHALL FURNISH AND INSTALL CONDUITS WITH CATEGORY 5 CABLING FROM ONE LOCATION TO ANOTHER(VARIOUS PLACES) IN ALL LOCATIONS SHOWN ON THE DRAWINGS -EITHER IN PLAN m I OR IN THE SCHEMATIC WIRING DIAGRAM DETAIL. CATEGORY 5 CABLING PROVIDED SHALL BE PROVIDED RUN EXTRA WIRE WITHOUT CONNECTORS ON THE ENDS AND WITH 10'-0"SLACK WHIPS AT EACH END FOR OWNESSE FOR GROUND (VENDOR WILL ULTIMATELY MAKE CONNECTIONS). IN INSTANCES WHERE PLENUM INSTALLATIONS ARE N (TYPICAL) ACCEPTABLE-CABEING RUN THROUGHOUT STORE IN THE PLENUM AREA SHALL BE SHIELDED/TEFLON O COATED,SUITABLE FOR INSTALLATION IN A PLENUM SPACE. U KEYNOTES ® KL�FFUNSI IT LL=UWDLORD 2 5 36.THE OWNER WILL FURNISH AND INSTALL A TRAFFIC COUNTER SYSTEM (SHOPPERTRAK-ORBIT SYSTEM) ^ FOR THE SPACE. CONTRACTOR SHALL FURNISH AND INSTALL CONDUITS WITH CATEGORY 5 CABLING FROM ONE LOCATION TO ANOTHER(VARIOUS PLACES) IN ALL LOCATIONS SHOWN ON THE DRAWINGS- EITHER IN 1. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL FIVE(5) 1"CONDUITS BELOW FLOOR ALL T.G.C. IG IG PLAN OR IN THE SCHEMATIC WIRING DIAGRAM DETAIL CABLE SHALL INSTALLED WITH 15'-0"TO 20'-0" WITH PULL STRINGS. CONDUIT STUB-UPS SHALL BE IN THE LOCATION SHOWN ON PLAN. SLACK AT EACH END. CATEGORY 5 CABLEING SHALL BE AS FOLLOWS: 4 PAIRS,24 AWG,SOLID STORE NUMBER 2 6 4 6 CONDUCTORS,TWISTED PAIRS,7 X 32 TINNED COPPER, 12.5 Pf, 110 OHMS,CL2 PLENUM RATED- 2. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL DEVICES FOR CASH DESK AS SHOWN T.G.C. BERK-EK CABLE#230247(SOLID PLENUM) OR BELDEN CABLE#1701A(BONDED,SOLID TWISTED PAIRS, ON PLAN AND LISTED BELOW: PLENUM)OR EQUAL IN INSTANCES WHERE PLENUM INSTALLATIONS ARE ACCEPTABLE-CABLEING RUN 1369 2.1. TWO(2)QUAD RECEPTACLES(ONE ISOLATED GROUND DUPLEX AND ONE GENERAL DUPLEX): E THROUGHOUT STORE IN THE PLENUM AREA SHALL BE AS MENTIONED BEFORE AND SHIELDED/TEFLON HUBBELL, MODEL#IG-5362 ORANGE IN COMMON J-BOX WITH WHITE 4 GANG COVER PLATE. COATED, SUITABLE FOR INSTALLATION IN A PLENUM SPACE. 2.2. TWO(2)DATA OUTLET: HUBBELL,TYPE RJ45 WffH WHITE COVER PLATE. I I 37.GENERAL PURPOSE RECEPTACLES SHALL BE MOUNTED 18"ABOVE FINISHED FLOOR AS REQUIRED WITH THE ELECTRICAL FEEDS TO EACH RECEPTACLE INSTALLED DOWN IN THE WALL. SEE ARCHITECTURAL 3. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL DEVICES FOR BACK WRAP AS SHOWN T.G.C. P I I I I DRAWINGS FOR ALL HEIGHTS,DIMENSIONS AND CONFIGURATIONS OF DEVICES NOT INDICATED ON THESE ISSUE ON PLAN AND LISTED BELOW: DRAWINGS. REFERENCE SAME DRAWINGS FOR EQUIPMENT NOT IDENTIFIED. *A*- ISSUE: ONE(1)QUAD RECEPTACLE(ONE ISOLATED GROUND DUPLEX AND ONE GENERAL DUPLEX): IIIII 38.VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO "A"DATE:E:PRELIMINARY HUBBELL, MODEL#5362 IN COMMON J-BOX WITH WHITE 4 GANG COVER PLATE. 7 IIIII INSTALLATION. FURNISH AND INSTALL OUTLET BOXES,DEVICES,COVERPLATES AND FLANGES AS REQUIRED. /28/22 39.SUPPORT ALL FIXTURES WITH UNISTRUT AS REQUIRED. 3.2. ONE(1)DUPLEX RECEPTACLE: HUBBELL, MODEL#5362 WITH WHITE COVER PLATE. 'B'-ISSUE:LL REVIEW / BID SET IIIII 3.3. ONE(1)PHONE OUTLET: HUBBELL,TYPE RJ11 WITH WHITE COVER PLATE. 40 NOT USED. 8 p IIIII DATE: 5/6/22 D 41..WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS,AND ONE YEAR GUARANTEE,COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 4. ALL CIRCUITS USED TO POWER THE CASH REGISTERS SHALL NOT BE USED FOR ANY OTHER T.G.C. I I I I 1 "C"-ISSUE:PERMIT SET 42. FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED,EXCEPT WHERE SPECIFIC APPROVAL FOR 8"RADIUS PURPOSE. CIRCUITS SHALL NOT SHALL NEUTRAL OR GROUND WITH ANY OTHER EQUIPMENT. I SUBSTITUTION IS GIVEN BY THE TENANT. DATE: 6/14/22 BUSHING WITH PULL STRING SEPARATE POWER, NEUTRAL AND ISOLATED GROUND WIRES MINIMUM SIZE#12 AWG SHALL BE 43. PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOS STUBBED TO ACCESSIBLE RUN TO THE CIRCUIT BREAKER PANEL BOARD WHERE GROUND WIRE SHALL BE TIED TO THE II "D"-ISSUE: LOCATION ABOVE CEILING TO TT CO MATERIALS N, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE DATE: CEIUNG GROUND TERMINAL ISOLATED FROM THE NEUTRAL. IR NOT USE CONDUIT FOR GROUNDING D TO TTB IIIII MATERIALS AND/OR A EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY THIS MAY NOT BE CONTINUOUS. CASH REGISTER CIRCUIT SHALL BE RUN IN SEPARATE CONDUIT. IIIII 3 ACCEPTANCE OF ALTERNATES. RECEPTACLES SHALL BE HUBBELL, MODEL#IG-5362 ORANGE. 8 IIIII 44.COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT 'E• DATE: (1) 1"CONDUIT 5. CASH DESK DEVICES SHALL BE SURFACE MOUNTED IN CABINET INTERIOR AT 12"A.F.F. FIELD T.G.C. T +18"A.F.F. 45.ALTERNATE SHALL BEI PROPOSALS IN NCLUDED THE BEERNATE PROPOSAL. CCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO 0 ACCESSIBLE VERIFY LOCATION OF CABINET SHELVING PRIOR TO INSTALLATION. I I CHANGES WILL B E E ALLOWED AFR THE CONTRACT IS SIGNED. "F'-ISSUE: SPACE IN CEILING III DATE: 46. UPOTHEN COMPLETION OF WORK, PREPARE LIGHTING AND POWER PROJECT RECORD AS-GUILTS. PRESENT (2)GANG DEEP BACK BOX 6 RJ45FURN(SH JACKSD INSTALL AT MANAGER'S DESK COMPUTER LOCATEORK D IN MANAGER'SLES FROM 45 JACK OFFICE.APROVDED18K TO VENDOR IIIII WORK,OAN PANELBOARDMPLETED G INFORMATION,FS TO THE INAL SWITCHINGR AS JILT D DRAWINGS SHALL INCLUDE ALL BRANCH CIRCUIT SHEAF TMX PROVIDE COVER PLATES- CABLES AT EACH LOCATION FOR CONNECTION TO CASH WRAP AND RECEIVING COMPUTER. 47.ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE PROOFED TO THE SAME OR COLOR SELECTED BY WITH SINGE GANG CABLES TO BE PLENUM RATED IF NOT INSTALLED IN CONDUIT. MOUNTED AT 5'-8"A.F.F. (ALL - - - - GREATER RATING THAN THAT OF THE ASSEMBLY. WHERE CONFLICT OCCURS, NOTIFY THE ARCHITECT. LOW VOLTAGE ARCHITECT EXTENSION BOX CH AFF- VERIFY WITH ARCHITECT LOW VOLTAGE WIRING SHALL BE INSTALLED BY TENANTS VENDOR) AL +18"A.F.F. 4 STUB-UP 48 ELEMENT,TIME DELAY.600 VOLT.ALL FUSES 600 AMPERES OR SSACCSHALL PTABLE MANUFACTURES ARE D,CLASS 1BUSSMAN,GOUL oa°SHAWMUT. DIAGRAMS AND FLOOR 7. FURNISH AND INSTALL NEW PANIC BUTTON AT CASH DESK. SENTROL, MODEL#3040. VENDOR (TYPICAL) 49.VERIFYCOMPL LOCAL ALL APPLICABLE SITE. ELECTRICAL 8. FURNISH AND INSTALL THE FOLLOWING SERVICE BUZZER SYSTEM IN LOCATIONS CALLED FOR AND T.G.C. 2,4,6 51.1 SECURE AND PAY FOR ALL REQUIRED PERMITS SPECIFICATIONS NOTE: INDICATED ON SHEET E200: 8 52.THE TENANT MAY HIRE AN INDEPENDENT CONTRACTOR/INSPECTOR TO VERIFY THE PROPER INSTALLATION 8. . EDWARDS#620 PUSHBUTTON W/147-1 PLATE MOUNTED AT 48"A.F.F.ON OUTSIDE OF REAR TO MANAGER'S OFFICE OF THE COMPLETE ELECTRICAL SYSTEM AS PER PLANS AND SPECIFICATIONS. SHOULD THERE BE ANY SLALE TYPICAL WHEN ANY OF THE FOLLOWING SYMBOLS T, AND ARE SHOWN ON PLAN. DOOR. (FIELD COORDINATE i, DISCREPANCIES IN THE INSTALLATION,THE CONTRACTOR WILL BE NOTIFIED IN WRITING AND HAVE EN(10) AS NOTED PROVIDE AS SHOWN ABOVE 8.2. EDWARDS#88-50 TRANSFORMER MOUNTED ABOVE MANAGER'S OFFICE DOOR. EXACT CONNECTION) 1"SPARE CONDUIT WORKING DAYS TO RECTIFY THE ERRORS. IF THE TENANT DECIDES IT IS NECESSARY TO VERIFY THAT THE 8.3. EDWARDS#340A-G5 BELL MOUNTED ABOVE MANAGER'S OFFICE DOOR. EXTEND TO ABOVE DEFICIENCIES HAVE BEEN CORRECTED BY MEANS OF A REINSPECTION,THE COST OF A REINSPECTION(PLUS 8.4. EDWARDS#340A-G5 BELL MOUNTED ABOVE CEILING AT CASH DESK PANEL LOCATION 10")WILL BE DEDUCTED FROM THE FINAL CONTRACT INVOICE. TELEPHONE/DATA RISER DETAIL CASH DESK WIRING DETAIL SHEET NUMBER NOT TO SCALE SCALE:1/2"=1'-0" E 4. 0 Page mm OO lO DATE: 4/26/22 JOB NO: 22-010 O ------- ---- ----- -------------- ' KEY NOTES® OWL G.C. DRAWN: STAFF A 1. FURNISH AND INSTALL NEW A.C. UNIT CONTROL. LIGHTSTAT, MODEL#TME-POI. T.G.C. CHECKED: DP 2. EXISTING TOILET EXHAUST FAN TO REMAIN. F- E� S1 -, 3. EXISTING RETURN AIR DUCT OPEN TO SPACE TO REMAIN. 50 4. EXISTING DUCT MOUNTED SMOKE DETECTOR TO REMAIN. x w Z 6"0 /� 5. EXISTING AIR CURTAIN TO REMAIN. c N a Z o a m I I I I I TEMPERATURE CONTROL NOTES 'm S1 1. FURNISH AND INSTALL NEW A.C.UNIT CONTROLS IN THE LOCATION SHOWN. UGHTSTAT, MODEL #TME-POI. 100 E%6"q EX IX 2. INSTALL IN THE LOCATION SHOWN. 400 400 3. VERIFY THE NUMBER OF CONTROL WIRES REQUIRED FOR A COMPLETE INSTALLATION. 4. INSTALLATION OF THE THERMOSTATS SHALL BE IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. Rt a a �+ �+ 5. ECONOMIZER CYCLE WILL BE FURNISHED AS A PART OF THE NEW A.C. UNIT. EX 100 6. WTTH SYSTEM ON 'DAY'CYCLE: SSTO NAL FN 250 24X24 6.1. SUPPLY FAN RUNS CONTINUOUSLY. 0�0 e�p%STE., G� - 1 6.2. ECONOMIZER CYCLE OPERATIVE. a Fp OIL— —J 6.3. THERMOSTAT SHALL ENERGIZE COOLING OR HEATING CYCLES IN THE AC UNIT AS REQUIRED. 8ai1 B RTU_1 7. WffH SYSTEM ON 'NIGHT'CYCLE: 10"q 7.2. ECONOMSUPPLYIZERFAN CYCLE INOPERATIVE, FRESH AIR DAMPER CLOSED. �grEOF P� 20"q 7.3. COOLING CYCLE INOPERATIVE. J.P 7.4. ON A CALL FOR HEATING FROM THE THERMOSTAT,FAN SHALL START AND HEATING CYCLE SHALL BE ENERGIZED; BOTH SHALL CONTINUE TO OPERATE UNTIL THE THERMOSTAT IS SATISFIED. 06/14/2022 —� 8. EXISTING SMOKE DETECTOR IN RETURN AIR DUCT TO REMAIN. 150 EX EX m I 260 26a PROJECT COORDINATION E. IX - 400 MECHANICAL GENERAL NOTES (ADDTuri RTU-1 4 225 OW(VNO Now,SUITE 105 TEL(IN�783-5670 1. THE SPACE IS EXISTING AND HAS BEEN OCCUPIED. WIN WINOSIR,CT 0607I TAM:(e)78i-56m 2. FURNISH AND INSTALL NEW DIFFUSERS AND REGISTERS AS SHOWN AND SPECIFIED. 3 \it FURNISH AND INSTALL VOLUME DAMPERS AT ALL NEW BRANCH TAKEOFFS. LLI 3. TEMPERATURE CONTROLS,INCLUDING WIRING,SHALL BE PART OF THE MECHANICAL ,^wN 0nr-� 5 t CONTRACT. V/Q:� i 4. FIBERGLASS DUCTWORK IS NOT PERMITTED. w!�^ w��l � 5. ALL DUCTWORK SHALL CONFORM TO THE LATEST EDITION OF SMACNA STANDARDS AND v/ 00 RECOMMENDATIONS. _ 150 6. DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS AND SHALL BE ADJUSTED IF LLI REQUIRED TO ACCOUNT FOR METHOD OF INSULATION. Q:f — 7. FIRE STOP ALL PENETRATIONS THROUGH FIRE RATED PARTITIONS(IF REQUIRED) IN O ® -J STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES. Q i n © o 8. NEW DUCTWORK SHALL BE INSTALLED USING THE FOLLOWING MATERIALS: 5 a VJ/ v -RIGID: GALVANIZED SHEET METAL,IN ACCORDANCE WITH ASHRAE AND SMACNA ___J J a EX EX REQUIREMENTS FOR LOW PRESSURE DUCTWORK. (1"WC) J Q _ -ROUND:SPIRO-SAFE ROUND DUCTWORK AND FITTINGS AS MANUFACTURED BY LINLAB, _ 280 280 INC. (OR EQUAL)GALVANIZED STEEL, IN ACCORDANCE WITH ASTM,ASHRAE AND _ SMACNA REQUIREMENTS FOR LOW PRESSURE DUCTS. ALL VOLUME DAMPERS SHALL BE O LL - SPIRO-SAFE TYPE DRU, DSU OR DTU OR APPROVED EQUAL. -FLEXIBLE: WIREMOLD TYPE WCK OR EQUAL FLEXIBLE CLASS 1 AIR DUCT,THICK, I 3/4 LB. DENSTIY FIBERGLASS INSULATION AND FIRE RETARDANT REINFORCED u/ z u METALIZED POLYESTER FILM LAMINATED ON SHEET WIRE REINFORCING,WITH 1.5"VAPOR BARRIER(HI-VINYL)AND SHALL MEET NFPA 90A AND UL STANDARD 181. Q G) Q IX 9. NEW DUCTWORK INSULATION SHALL BE INSTALLED USING THE FOLLOWING MATERIALS: -WRAP: 1.5"THICK,3/4 LB.DENSITY FIREBERGLASS INSULATION WITH VAPOR g•q @ g•q 40o BARRIER JACKET. H 10.FURNISH AND INSTALL NEW VOLUME DAMPERS AT ALL DUCTWORK TAKE-OFFS. RTU-2 11.EXISTING DUCTWORK TO REMAIN,SHOWN HATCHED. I R2 M i 3 SYMBOLS AND ABBREVIATIONS 0 L__----- m i CFM CUBIC FEET PER MINUTE SI CD CONDENSATE DRAIN RAR RETURN AIR REGISTER 0 O \--- RTU-2 S.A. SUPPLY AIR O - - - - - - - - - R.A. RETURN AIR 10"0 1 O.A. OUTDOOR AIR \ 0THERMOSTAT STORE NUMBER (if ,— 0 1369 EX I\ 250 I I I 50 I I I I ISSUE - x 'A'-ISSUE:PRELIMINARY I I IX DATE: 4/26/22 EX 'B.-ISSUE:LL REVIEW / BID SET EX IX DATE: 5/6 2so 2so 400 5p ICI-ISSUE:PERMITT SET e _ DATE: 6/14/22 EX 2 'D'-ISSUE: DATE: E-ISSUE: I I I I I I DATE: F-ISSUE: EX 2 DATE: I I I IX I I I I I SHEET TIRE EX 5o FLOOR PLAN �- IX 50 CITY APPROVED PLANS MECHANICAL e O WORK Reviewed for Code Compliance SCALE E --- -- ---- PLANS MUST BE ON JOB SITE 1/4" = 1'-0" -- ------- --- - -------------- I FOR ALL INSPECTIONS SHEET NUMBER LIGHTS HAVE BEEN TURNED OFF FOR CLARITY-SEE SHEET El.0 OR FLOOR PLAN - MECHANICAL WORK ARCHITECTURAL RCP FOR LOCATIONS. � /� 1 y O SCALE:1/4"=1'-0" V Page - DATE: 4/26/22 HVAC UNIT SCHEDULE (EXISTING) MAN SUPPLY DUCE MECHANICAL WORK NOTES - GENERAL JOB: z2-o10 MOD N NOMINAL SA OSA ­1 INQ CAPACITY TING CAPACITY CTRICAL DRAWN: STAFF MARK SENSIBLE TOTAL ER/ INPUT OUTPUT EVAP. FAN COMPRESSORS CONDENSER FAN OWT. REMARKS ~ ADJUSTABLE METAL 1. MECHANICAL WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MODEL NO. TONS GEM CFM (MBH) (MBH) SEER (MBH) (MBH) VOLT PH. FLA QTY RLA LRA QTY. HP FLA CIRCUIT BS ROD OR LINKAGE AMPS LBS. MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED,SHOWN OR VOLUME EXTRACTOR;ADJUSTABLE REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CHECKED: DP IX. RN-1 CARRIERTHEFRO CLOSED POSITION TENANT.TOR WHENMAKE REQUESTED IN THE PLAN V✓EMI INTENT OF THE CONTRACT. IX.RN-2 CARRIER B 7.5 3000 600 EX 83.0 11/- 180 148 208 3 13.6 2 13.6 83.0 2 - 1.5 51.0 EX 1002 O3 SUPPLY��Tom- 2 SUBMITTING A PROPOSAL FOCTOR R WORK ASSIT THE IDESCRIB OTE AND IXANDLSHOWNING NO EXTRAS CONDITIONS WILL BE >a m ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. m A, z 3. MECHANICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS o x w z 1O LOW AMBIENT CONTROL TO 0' O RATED®80' EDB, 6T EWB, 95'AMBIENT MAIN SUPPLY DUCT OF THE JOB SITE,INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE c In Wa OF THE WORK. o ai o Z ���� 0 6 4. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE a o O PROVIDE 5 YEAR COMP.WARRANTY O STANDARD EFFICIENCY MODEL COMPLETE WITH ECONOMIZER CYCLE AND ALL FACTORY SAFETY AND OPERATING CONTROLS o 1 4 W 0 DURATION OF THE PROJECT AS REQUIRED TO COMPLY IN EVERY WAY NECESSARY. 4/(100 MM)MIN. PROVIDE VOLUME DAMPER 5. COTRACTOR SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER OF ERROR,OMISSIONS OR ron v m O PROVIDE 2"THICK THROWAWAY FILTERS O CARRIER,YORK AND LENNOX ARE ACCEPTABLE ALTERNATES. CONTRACTOR SHALL SUBMIT ALTERNATE FOR APPROVAL. SEE NOTES#23-25 UNDER WHEN SHOWN ON FLOOR PUNS MECHANICAL WORK NOTES-GENERAL FOR ALTERNATE SUBMITTAL INSTRUCTIONS. DISCREPENCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK,OR FAILING SUCH O4 FURNISH AND INSTALL MANUFACTURER CURB. ND/OR NOTICE SHALL BE EAM NEER,RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT,ARCHITECT PLAN NEW 6. ORDER EQUIPMENT ON A TIMELY BASIS(WITHIN 5 DAYS OF RECEIPT OF CONTRACT)TO MAINTAIN BRANCH DUCT TAKE-OFF CONSTRUCTION SCHEDULE. LL I 7. SUBMIT ELECTRONIC COPY OF SHOP DRAWINGS FOR APPROVAL FURNISH ONLY SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. SEE FLOOR PLAN FOR SPLIT DIMENSION 8. WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE v INSTRUCTIONS,WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 9. WORK SHALL ALSO INCLUDE A FULL ONE(1)YEAR MAINTENANCE, PARTS AND SERVICE AIR DEVICE SCHEDULE y CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. 10.ON ALL AIR CONDITIONING EQUIPMENT WHICH INCLUDES COMPRESSORS(ROOF-TOP,SPLIT MAIN SUPPLY PROVIDE VOLUME DAMPER SYSTEMS,ETC.) INCLUDE AN EXTENDED FOUR(4)YEAR WARRANTY FOR THE COMPRESSOR. DUCT WHEN SHOWN ON FLOOR PLANS 11.VOLUME DAMPERS,SPUTTERS AND DEFLECTORS SHALL BE INSTALLED IN ALL DUCTS TO PERMIT MARK SERVICE TYPE MODULE/FACE BACKPN MFGR.&MOD.N0. BORDER PATTERN NOTES COMMENTS ACCURATE BALANCING OF THE SYSTEM. THE DAMPERS, SPUTTERS AND DEFLECTORS SHALL BE R,\ONAk FN SIZE TYPE ADJUSTED TO SATISFY THE HVAC REQUIREMENTS OF THE CONDITIONED SPACE AND LOCKED IN �p16TER G TURNING VANES PLACE AS REQUIRED. O e o 2m S1 SUPPLY SQUARE 24"X 24" 18"X 18" TITUS TDCA 3-LAY-IN 4-WAY 2,4,7,12 SQUARE ELBOW SHOWN. ¢ m SUPPLY REGISTER OR BRANCH DUCT PROVIDE ROUND ELBOW 12.WORK SHALL ALSO INCLUDE TESTING AND BALANCING OF A.C.SYSTEM BY A CERTIFIED a p WHEN SHOWN ON FLOOR PLANS BALANCING CONTRACTOR. CONTRACTOR SHALL SUBMIT COPIES OF TEST AND BALANCE REPORTS 8011 BORDER CORE AREA PUN SHOWING DETAILED RESULTS OF WORK, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: FLOW AIR SPOT DUCT TAKE-OFF READINGS,STATIC PRESSURES,TEMPERATURE READINGS, MOTOR AMPERAGE, BALANCING OF AIR R1 RETURN SQUARE 24"X 24" SEE PLAN TITUS 50F 3-LAY-IN - 10.12 QUANTITIES TO PLAN REQUIREMENTS, ETC.AS REQUIRED. MAKE ALL ADJUSTMENTS AS grEOF P� REQUIRED TO PROVIDE DESIGN AIR FLOW. RETURN/ DESIGNER'S NOTES: 13.FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE J.P R2 TRANSFER RECETNGLL 'EA.DIM) SEE PLAN TITUS 350FL 1 -SURFACE PROJECT. 1. THE SUPPLY REGISTER TAKE-OFF MAY BE USED FOR UP UP TO 25%OF THE MAIN DUCT CFM. 14.WHERE APPLICABLE, FURNISH AND INSTALL VIBRATION ISOLATION AS REQUIRED TO REDUCE, 06/14/2022 THE BRANCH DUCT TAKE-OFF MAY BE USED FOR UP TO 15%OF THE MAIN DUCT CFM ANYTIME LIMIT ND/OR REMOVE ALL VIBRATIONS FOR ALL MOVING EQUIPMENT. VIBRATION ISOLATION NOTES: AND UPTO 40%WHEN THE MAIN DUCT VELOCITY IS 1000 FPM(5 M/S)OR LESS.THE AIR SPLIT DIFFUSER REGISTER TYPE DUCT TAKE-OFF SHALL BE USED IN ALL OTHER CASES AND MAY BE USED AT ANYTIME. SHALL BE IN ACCORDANCE WITH ASHRAE RECOMMENDATIONS. 1. PROVIDE WITH AG-35-M OPPOSED BLADE VOLUME DAMPER(RECT.272RS&23RL) 15.PROVIDE ENGRAVED BAKELITE NAMEPLATES FOR ALL MECHANICAL EQUIPMENT INCLUDING 2. PROVIDE WITH MODEL EG EQUALIZING GRID A G 2. SHOW VOLUME DAMPERS ON FLOOR PLANS. TENANT'S NAME AND SPACE NUMBER.LETTERS SHALL BE 2"HIGH OR AS REQUIRED BY THE PROJECT COORDINATION {''� 3. PROVIDE WITH MODEL AG-75 OPPOSED BLADE VOLUME DAMPER(SQUARE) LAN400 1200 16.ALL FABRICATED COMPONENTS(CONTRACTOR OR MANUFACTURER)OF THE OUTSIDE AIR,SUPPLY C,`r,DDT�\I DLORD 4. PROVIDE WITH MODEL ASTER OPPOSED BLADE VOLUME DAMPER(ROUND) `'\ 5. PROVIDE WITH TRIMRUS PLASTER FRAME 6'0 `AIR QUANTITY(CFM) 16X16 AIR QUANTITY(CFM) SUPPLY DUCTWORK TAKE-OFFS AIR, RETURN AIR AND EXHAUST AIR SYSTEMS SHALL BE CONSTRUCTED AND INSTALLED AIR 6. PROVIDE WITH RUSKIN MODEL CFD FIRE DAMPER TIGHT. THE INSTALLED SYSTEMS SHALL BE PRESSURE TESTED AS REQUIRED. 7. LIMIT FLEXIBLE DUCT CONNECTION TO 5'-0"MAXIMUM 17.FURNISH TWO(2)COPIES OF AS-BUILT DRAWINGS OF THE A.C.SYSTEM TO THE OWNER FOR 225 ONNND ROAD,SUITE IDS TEL(866 783-5670 8. PROVIDE WITH TAUS MODEL MPI37 INSULATED PLENUM CONNECTION DUCT SIZE CORE AREA NOT TO SCALE REVIEW AND APPROVAL,OR SUBMIT A LETTER TO THE OWNER CONFIRMING THAT THE SYSTEM SNRN 1RNDSM,CT 06074 FAX:IN 783-5680 (DO NOT SUPPLY FOR BLANK SECTIONS) WAS INSTALLED AS PER PLANS AND SPECIFICATIONS. 9. PROVIDE PREFAB PLASTER FRAME FOR MOUNTING 18.ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE TENANT BEFORE 10. ROVI M FIR WITH MODEL AG-15- VOLUME DAMPER(RETURN RECT.50F) TURNING PROJECT OVER TO THE TENANT. Li 11. COMPLETE WITH SHEET METAL,WALL SLEEVE AND TAMPER PROOF SCREEN 19.SEAL ALL PENETRATIONS THROUGH WALLS,CEILINGS,FLOORS,ETC.SO THAT THEY ARE AIR, LLI 12. PRICE AND KRUEGER ARE ACCEPTABLE ALTERNATES. CONTRACTOR SHALL SUBMIT ALTERNATE WATER AND FIRE TIGHT. w O (� FOR APPROVAL. SEE NOTES#23-25 UNDER MECHANICAL WORK NOTES-GENERAL FOR 20.FURNISH AND INSTALL ACCESS PANELS FOR ALL CONCEALED EQUIPMENT, FIRE DAMPERS, PIPING Y�Y/ nr-� ALTERNATE SUBMITTAL INSTRUCTIONS. VALVES,CLEANOUTS,ETC. ACCESS PANELS SHALL BE OF SUFFICIENT SIZE TO PROVIDE Cn(y ' 1 CE AND 1. PULL OUTER INSULATION JACKET BACK AND SLIDE INNER 21.FURNSHTALL MATERIAL ANEQ WORKINGRD EQUI ME T•AS SPECIFIED,EXCEPT WHERE SPECIFIC APPROVAL FOR LLI N LINE OVER SHEETMETAL COLLAR SUBSITTUTION IS GIVEN BY THE TENANT. >V) CIO22.PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT IN ORDER TO PROMOTE COMPETITION,HOWEVER BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY OUTER INSULATION JACKET ALTERNATE MATERIALS AND/OR EQUIPMENT THEY WISH TO PROPOSE,INCLUDING ANY PRICE W Q CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 23.COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE N \ EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL. LL O SHEETLIEIAL 24.ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. '^ BOOT COLLAR NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. ANY UNAUTHORIZED Q V l CHANGES TO THE DESIGN AND LAYOUT MAY BE REQUIRED TO BE REMOVED AT CONTRACTOR'S 7� J IN DUCT UNER EXPENSE IF DEEMED NECESSARY BY THE ARCHITECT, ENGINEER OR OWNER'S REPRESENTATIVE. L1 25.VERIFY LOCAL CONDITIONS AT SITE. J SUPPLY DIFFUSER OR 26.COMPLY WITH ALL APPLICABLE CODES. _J RETURN AIR GRILLE 27.SECURE AND PAY FOR ALL REQUIRED PERMITS. z Q 28.SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING GRID,LIGHT FIXTURES, ETC. 29.ALL INSULATION MATERVJS, INCLUDING BUT NOT LIMITED TO DUCT INSULATION AND PIPING O INSULATION SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS(ON THE FLAME SPREAD TEST SCALE)AND SMOKE DEVELOPMENT OF 50 OR LESS(ON THE SMOKE TEST SCALE)OR AS 7 DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OR SURFACE BURNING CHARACTERISTICS U z Z u 2.. TAPE INNER-LINER TO SHEETMETAL COLLAR WITH SILVER OF BUILDING MATERIALS, LOCAL CODES AND LOCAL AUTHORITIES HAVING JURISDICTION. DUCT TAPE. DUCT TAPE SHOULD BE WRAPPED AROUND 30.DIELECTRIC UNIONS SHALL BE USED TO CONNECT DISSIMIIJAR METALS OR METAL PIPING SHALL QHAVE METAL ON Q TO MATCH THE ADJACENT PIPING. SHEETMETAL. COLLAR TWO FULL TURNS 0 PO ENTS•SHALL•BENSEPARATEDH BY A AENDHREADED NYLON INSULATOR TOPREVENT CURRENT FLOW METAL �J BETWEEN DISSIMILAR METALS UNIONS SHALL BE SUITABLE FOR THE SYSTEM OPERATING PRESSURES AND TEMPERATURE WELD TYPE: ASTM A-234. OUIUR INSULATION JACKET BOOT CLIP MECHANICAL WORK NOTES -AIR FILTERS BOOT COLLAR INNER DUCT UNER C) O SUPPLY DIFFGRILLE OR 1.ON THE DAY OF STORE CONSTRUCTION COMPLETION/TURNOVER,THE AIR m RETURN AIR CONDITIONING EQUIPMENT FILTERS, IF ANY, (WHETHER NEW CONSTRUCTION OR DUCT TAPE EXISTING)SHALL BE REPLACED WITH NEW FILTERS. SI o L H 3. PULL OUTER INSULATION HACKET OVER SHEETMETAL COLLAR U O JAND PLACE A ACKET T� L BAND THE AD INSULATED KET BELOW SHEETMETAL COLLAR A.C. UNIT REFURBISHMENT NOTES V STORE NUMBER 1.BASE BID SHALL INCLUDE A DETAILED FIELD INSPECTION OF THE EXISTING A.C. UNITS OUTER INSULATION JACKET TO DETERMINE THEIR CONDITION AND COSTS TO PERFORM MAINTENANCE SERVICE ON EXISTING SYSTEM AS REQUIRED TO GUARANTEE PROPER OPERATION,CONSISTING OF, BUT 1369 NOT LIMITED TO,THE FOLLOWING: A CHECK AND ADJUST BELTS. REPLACE IF REQUIRED. SHEETMETAL B. CHECK FAN FOR PROPER OPERATION. REPLACE BEARINGS IF REQUIRED. BOOT COLLAR C. CHECK REFRIGERNT PIPING SYSTEM FOR LEAKS. REPAIR AS REQUIRED. D. CHECK REFRIGERANT CHARGE. ADD REFRIGERANT AS REQUIRED. ISSUE INNER DUCT LINER E. REPLACE REFRIGERANT FILTER/DRIER IF EXISTING. 'A'-ISSUE:PRELIMINARY F.CHECK REFRIGERANT LINE PRESSURES. IF ABOVE RATED LIMITS,CLEAN AND/OR DATE: 4/26/22 SUPPLY DIFFUSER OR REPLACE PIPING AS REQUIRED. RETURN AIR GRILLE METAL DRAW SAI1D G.CHECK COMPRESSOR AND FAN MOTOR AMPERAGE. IF ABOVE RATED LIMTTS, REPLACE 'B'-ISSUE:LL REVIEW / BID SET AS REQUIRED. DATE: 5/6/22 H.CLEAN COIL SURFACE IF REQUIRED. I.REPLACE FILTERS. 'C'-ISSUE:PERMIT SET J. CHECK AND ADJUST CONTROLS. DATE: 6/14/22 K. REPAIR ANY RUSTED AREAS ON UNIT CASINGS. REPAINT AS REQUIRED. 4. CUT EXCESS METAL DRAW BAND OFF AND WRAP METAL L CHECK HEAT EXCHANGER FOR PROPER OPERATION AND/OR DETERIORATION. 'D'-ISSUE: AS REQUIRED. DRAW BAND WITH SILVER DUCT TAPE. M.CHECK•AND REPLACE FAN PROVING SWITCH TO ENSURE PROPER OPERATION OF DATE: HEATING CYCLE,ETC. 'E'-ISSUE: N.ADJUST AS REQUIRED TO DELIVER AIR QUANTITY SHOWN OR CALLED FOR. DATE: OUTER INSULATION JACKET 2.SUBMIT AN ALTERNATE PROPOSAL ACCOMPANYING BID TO REPLACE ALL EXISTING EQUIPMENT,WHICH WILL BE CONSIDERED BY THE TENANT IF THE EQUIPMENT IS 'F'-ISSUE: DETERMINED TO BE IN NEED OF REPLACEMENT AFTER THE INITIAL INSPECTION AT THE JOB DATE: SITE. ALTERNATE PROPOSAL SHALL BE COMPLETE, INCLUDING LABOR,RIGGING COSTS(IF SHEUMETAL ANY), ETC. BOOT COUM SHEET TEE INNER DUCT LINER MECHANICAL SUPPLY DIFFUSER OR DUCT TAPE WRAPPED DETAILS RETURN AIR GRILLE OVER METAL DRAW BAND CITY APPROVED PLANS SCALE Reviewed for Code Compliance AS NOTED FLEX DUCT CONNECTION TO DUFFUSERS, PLANS MUST BE ON JOB SITE SHEET NUMBER GRILLES AND SHEETMETAL PLENUM COLLARS FOR ALL INSPECTIONS M 2 NOT TO SCALE Pa e DATE: 4/26/22 PLUMBING FIXTURE SCHEDULE ROUGH-IN SCHEDULE REMARKS JOB NO: 22-010 DRAWN: STAFF MARK MANUFACTURER 8 MODEL NO. TRIM CW HW WASTE VENT MTG.HT. / II CHECKED: DP -- I TOTO 'DRAKE'FLOOR MOUNTED,1.28 GPF,ELONGATED,SIPHON ACTION WC-1 MODEL NO.,CST 744SL-ADA JETTED BOWL,ADA COMPLIANT 16.5"RIM HEIGHT.PROVIDE WITH 1/2" - 4" 2" L-1 I( SEAT,LESS COVER. N O 1 AMERICAN STANDARD AMERICAN STANDARD,MODEL#6053.205 FAUCET,SUPPLIES,STOPS, 1/2" 12" 2" 1 1/2" m y um Z Q MODEL#0124.024 DRAIN,P-TRAP AND WALL HANGERS. Z O•)H N W oV z STATE 6 GALLON ELECTRIC WATER HEATER,6 GPH RECOVERY 100-RISE,120 3/4" 3/4" _ -- EXISTING WATER HEATER SHALL BE IN LIKE NEW CONDITION o a WH-1 OR REPLACED.IF REPLACEMENT IS REQUIRED PROVIDE AS on MODEL#PCE-6-10MSA VOLT,1 PHASE,1.5 KW WITH EXPANSION TANK,STATE,MODEL#ETC-2X. SPECIFIED HERE. 62M-p m � EX. WATER w 2-�4C_1COOLER I III 3 U TWC-1 EX. SNK PLUMBING FIXTURE KEY NOTES ® LL=LANDLORD i T.G.C.=TDbWT G.C. �O NAL 2 1. FURNISH AND INSTALL NEW WATER CLOSET(WC-1)IN EXISTING LOCATION. T.G.C. CONNECTION SCHEDULE O�F'Se 018TEq��G� RECONNECT COLD WATER,SANITARY AND VENT AS REQUIRED. ROUGH-IN a Fp 2. FURNISH AND INSTALL NEW LAVATORY(L-1)IN EXISTING LOCATION. RECONNECT T.G.C. FIXTURE REMARKS 8a11 SANITARY,VENT, HOT AND COLD WATER AS REQUIRED. O - - - 3. EXISTING WATER HEATER ABOVE TOILET ROOM TO REMAIN. LANDLORD SHALL T.G.C. cOA3 =3 3 > �g7'BOF P� ENSURE WATER HEATER IS IN LIKE NEW CONDITION OR REPLACE AS REQUIRED. LAVATORY 1/2' 1/2' 2" 1 1/2" J.P 06/14/2022 WATER CLOSET 1/2" - 3" 2• GENERAL NOTE FLOOR PLAN - PLUMBING WORK A. PIPING MATERIALS: MOP SINK 1/2" 1/2 3" 1 1/2" PROJECT COORDINATION SCALE:1/4"=1'-O" A.A. DOMESTIC WATER: TYPE L HARD TEMPER COPPER WITH WROUGHT SWEAT C>A,DDT�\I {-� FITTINGS. ELECTRIC 1/2' - 2• 1 1/2" A.B. WASTE AND VENT: STANDARD WEIGHT CAST IRON WITH HUB AND SPIGOT WATER COOLER FITTINGS. 225 OAKLAND ROAD,SUITE 1D5 TEL(866 783-5678 A.C. DOMESTIC WATER PIPE INSULATION: 1"THICK,3/4"LB. DENSITY FIBERGLASS WATER 3/4" _ _ _ SOUTH WRNaR CT OfiA74 FAX:IN 783-5680 WITH VAPOR BARRIER JACKET. HEATER FLOOR _ _ 2" _ W Li DRAIN I O Cn N V L_L W[-- rq N PLUMBING CALCULATIONS 0_� PLUMBING FIXTURE QTY.SAN F.0 AN F.0 C.W F.U.WTR. DMD. W 0 EACH TOTAL EACH TOTAL Q:f BATH ROOM GROUP 2 5 10 3.6 7.2 Q 0 r MOP SINK 1 2 2 3.0 3.0 a J ELECTRIC WATER COOLER 1 o.s o.s as 0.25 J O) FLOOR DRAIN 0 2 0 - - z Q TOTALS 12.5 10.45 N SERVICE CONNECTION SIZE SAN.: 4" WATER:31r z Lf) Z u Q Cn n U I u� PLUMBING WORK NOTES - GENERAL 1. PLUMBING WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED,SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT,WHEN SUCH ADJUSTMENTS ARE I NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 2. PLUMBING CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS LM DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. O 3. PLUMBING CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 0 0 4.CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE PROJECT AS REQUIRED TO m COMPLY IN EVERY WAY NECESSARY. W 5.CONTRACTOR SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER OF ERRORS,OMMISSIONS OR DISCREPENCIES BEFORE CONSTRUCTION OR T I FABRICATION OF AFFECTED WORK,OR,FAILING SUCH NOTICE,SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, L + ARCHITECT OR ENGINEER. f w 6.ORDER EQUIPMENT ON A TIMELY BASIS(WITHIN 5 DAYS OF RECEIPT OF CONTRACT)TO MAINTAIN CONSTRUCTION SCHEDULE. 7.SUBMIT FIVE(5)COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER/ARCHITECT. ONE(1)COPIES WILL BE O RETAINED FOR RECORD. ONLY FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. U 8.WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS,FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS,WARRANTEE FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP,COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 9.WORK SHALL ALSO INCLUDE FULL ONE(1)YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. 10. FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION STORE NUMBER OF THE PROJECT. 11.WHERE APPLICABLE,FURNISH AND INSTALL VIBRATION ISOLATION AS REQUIRED TO REDUCE, LIMIT OR REMOVE ALL VIBRATIONS FOR ALL MOVING EQUIPMENT. VIBRATION ISOLATION SHALL BE IN ACCORDANCE WITH ASHRAE RECOMMENDATIONS. 12.ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 1369 13. SEAL ALL PENETRATIONS THROUGH WALLS,CEILINGS,FLOORS,ETC. SO THAT THEY ARE AIR,WATER AND FIRE TIGHT. 14. FURNISH AND INSTALL ACCESS PANELS FOR ALL CONCEALED EQUIPMENT,FIRE DAMPERS,PIPING VALVES,CLEANOUTS,ETC. ACCESS PANELS SHALL BE OF SUFFICIENT SIZE TO PROVIDE ADEQUATE WORKING CLEARANCE AND ACCESS. 15. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EACH FIXTURE. FURNISH AND INSTALL AN ACCESSIBLE SERVICE VALVE ON ALL ISSUE BRANCH PIPING. 16. FURNISH AND INSTALL CHAMBER SHOCK ABSORBERS AS SHOWN TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. 'A'-ISSUE:PRELIMINARY 17. FURNISH AND INSTALL PRESSURE REGULATOR ON THE INCOMING WATER SERVICE IF SERVICE PRESSURE EXCEEDS 80 PSI. DATE: 4/26/22 18. FURNISH AND INSTALL ALL PIPE HANGERS,CARRIERS, SADDLES,AND SUPPPOTS TO PROPERLY SUPPORT AND PROTECT ALL PIPING IN THE SPACE AS REQUIRED. 'B'-ISSUE:LL REVIEW / BID SET HANGERS FOR HORIZONTAL PIPING WHERE PIPING IS TO BE INSULATED BE LARGE ENOUGH TO PASS INSULATION AND SHALL BE ELCEN FIG. 12 DATE: 5/6/22 CLEVIS TYPE,WITH MEANS FOR VERTICAL ADJUSTMENT. INSTALL HANGERS AS FOLLOWS: PIPE SIZE HANGER ROD SIZE MAXIMUM SPACING 'C'-ISSUE:PERMIT SET 1/2'TO 1" 3/8" 8'-0"O.C. DATE: 6/14/22 1-1/4"TO 2• 3/8' 10'-0"O.C. 'D'-ISSUE: 2-1/2•AND ABOVE 1/2" 10'-0"O.C. DATE: 19.VERIFY LOCATION, DEPTH AND SIZE OF EXISTING SANITARY SEWER AT SITE. CONNECT AS REQUIRED. SEWER SHALL BE INSTALLED WITH 1/4"PITCH PER FOOT AND OUTSIDE SEWER SHALL BE INSTALLED WITH MINIMUM OF 3'-0"COVER. 'E'-ISSUE: 20. FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION DATE: OF THE PROJECT. 21.ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING PROJECT OVER TO THE OWNER. 'F'-ISSUE: 22. FURNISH AND INSTALL TRAP PRIMERS ON ALL FLOOR DRAINS. DATE: 23. FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED,EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT. 24. PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION,HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND/OR EQUIPMENT THEY WISH TO PROPOSE,INCLUDING ANY SHEET TITLE PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 25.COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE FLOOR PLAN ALTERNATE PROPOSAL. 26.ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CITY APPROVED PLANS CONTRACT IS SIGNED. ANY UNAUTHORIZED CHANGES TO THE DESIGN AND LAYOUT MAY BE REQUIRED TO BE REMOVED AT CONTRACTOR'S PLUMBING EXPENSE IF DEEMED NECESSARY BY THE ARCHITECT, ENGINEER OR OWNER'S REPRESENTATIVE. 27.VERIFY LOCAL CONDITIONS AT SITE. WORK 28.COMPLY WITH ALL APPLICABLE CODES. Reviewedor Code Compliance f p SCALE 29.SECURE AND PAY FOR ALL REQUIRED PERMITS. 30.SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEIUNG GRID, LIGHT FIXTURES, ETC. PLANS MUST BE ON 10B SITE 31.ALL INSULATION MATERIALS,INCLUDING, BUT NOT LIMITED TOO DUCT INSULATION AND PIPING INSULATION SHALL HAVE A FLAME SPREAD 1/4" = 1'_0" RATING OF 25 OR LESS(ON THE FLAME SPREAD TEST SCALE)AND SMOKE DEVELOPMENT OF 50 OR LESS(ON THE SMOKE TEST SCALE)OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, LOCAL CODES AND LO ORITIES HAVING FOR ALL INSPECTIONS 32. DELECTRICHUNIONS SHALL BE USED TON CONNECT DISSIMIUAR METALS OR METAL PIPING SHALL HAVE METAL CONNECTIONS ON EACH END SHEET NUMBER THREADED TO MATCH THE ADJACENT PIPING. METAL COMPONENTS SHALL BE SEPARATED BY A NYLON INSULATOR TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. UNIONS SHALL BE SUITABLE FOR THE SYSTEM OPERATING PRESSURES AND TEMPERATURE WELD TYPE:ASTM P 1 A-234. Page