Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17-2468 1925 Fillmore St #300 Restaurant Plans
17-2468 COMcheck Software Version 4.0.6.2 11925FillmoreSt #300 86/1' Interior Lighting Compliance Certificate Project Information Energy Code: 2012 IECC Project Title: Habit Burger Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 1925 Fillmore St Habit Burger Darrell Case Suite 300 17320 Red Hill Ave AEdifica Case Twin Falls, ID 83301 Suite 140 796 Merus Court Irvine, CA 92614 St. Louis, MO 63026 949-851-8881 636-349-1600 www.habitburger.com Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Common Space Types:Family dining area 3005 1.40 4207 Total Allowed Watts= 4207 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Common Space Types:Family dining area(3005 sq.ft.) LED D3N: D3N:4"DOWNLIGHT: LED PAR 8W: 1 77 8 578 LED D2F:D2F:4"DOWNLIGHT: LED PAR 8W: 1 2 8 15 LED D4F:D4F:4"DOWNLIGHT: LED PAR 8W: 1 4 8 30 LED D5S:D5S:4"DOWNLIGHT:LED PAR 8W: 1 20 8 150 LED D5F:D5F:4"DOWNLIGHT: LED PAR 8W: 1 7 8 52 LED D7: D7:6"DOWNLIGHT: LED PAR 18W: 1 8 18 144 Linear Fluorescent K1/2:K1/2:2x4:48"T8 32W(Super T8): Electronic: 2 15 68 1020 LED L1-3: 1-1-3:LED Pendant: LED PAR 13W: 1 31 13 403 LED W3:W3: LED Sconce:Other: 1 2 17 34 LED W4:W4: LED Sconce:Other: 1 2 25 50 Total Proposed Watts= 2476 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.6.2 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Daf ell Case SWWALLgE,N 9/5/17 Name Title 1S�^J j�� Date a. N 9316 0 499 OF %OGS�' Project Title: Habit Burger E�R R. Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit Bu, . ,s, ID\docs\ELECTRICAL COMN Page 1 of 12 CHECK IECC-12.cck 6 COMcheck Software Version 4.0.6.2 �( Mechanical Compliance Certificate Project Information Energy Code: 2012 IECC Project Title: Habit Burger Location: Twin Falls, Idaho Climate Zone: 5b Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 1925 Fillmore St Habit Burger Darrell Case Suite 300 17320 Red Hill Ave AEdifica Case Twin Falls, ID 83301 Suite 140 796 Merus Court Irvine, CA 92614 St. Louis, MO 63026 949-851-8881 636-349-1600 www.habitburger.com Mechanical Systems List Quantity System Type&Description 1 HVAC System 1 (Single Zone): Heating: 1 each-Duct Furnace,Gas,Capacity= 160 kBtu/h Proposed Efficiency=80.00%Ec, Required Efficiency=80.00%Ec Cooling: 1 each-Single Package DX Unit,Capacity=91 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=12.60 EER, Required Efficiency: 11.00 EER +11.2 IEER Fan System: FAN SYSTEM 1 --Compliance(Motor nameplate HP method): Passes Fans: FAN 1 Supply,Constant Volume,3000 CFM,2.8 motor nameplate hp 1 HVAC System 2(Single Zone): Heating: 1 each-Duct Furnace,Gas,Capacity=200 kBtu/h Proposed Efficiency=80.00%Ec, Required Efficiency=80.00%Ec Cooling: 1 each-Single Package DX Unit,Capacity= 107 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=12.40 EER, Required Efficiency: 11.00 EER +11.2 IEER Fan System: FAN SYSTEM 2--Compliance(Motor nameplate HP method): Passes Fans: FAN 2 Supply,Constant Volume,4000 CFM,3.8 motor nameplate hp 1 HVAC System 3(Single Zone): Heating: 1 each-Duct Furnace,Gas,Capacity=479 kBtu/h Proposed Efficiency=80.00%Ec, Required Efficiency=80.00%Ec Fan System: FAN SYSTEM 3--Compliance(Motor nameplate HP method): Passes Fans: FAN 3 Supply,Constant Volume,6480 CFM,3.0 motor nameplate hp Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.6.2 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. S\()NAL Darrell Case ��5 G%STE N�,� 9/5/17 Name-Title Q Q�li f� ��. Date 9316 0 Project Title: Habit Burger N:A Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit B Is, ID\docs\ELECTRICAL COMN Page 2 of 12 CHECK IECC-12.cck "91(� o� SELL R.G COMcheck Software Version 4.0.6.2 Inspection Checklist Energy Code: 2012 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans, specifications, and/or ❑Complies Requirement will be met. [PR2]1 !calculations provide all information ❑Does Not with which compliance can be determined for the mechanical ❑Not Observable systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans, specifications, and/or ❑Complies Requirement will be met. [PR4]1 calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting ❑Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to !the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Habit Burger Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit Burger\XLTF-01-2017 Twin Falls, ID\docs\ELECTRICAL COMN Page 3 of 12 CHECK IECC-12.cck Section # Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID C403.2.4. ;Freeze protection and snow/ice ❑Complies Exception: Requirement does not apply. 5 melting system sensors for future :❑Does Not [FO9]3 ;connection to controls. ❑Not Observable j❑Not Applicable Additional Comments/Assumptions: F I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Habit Burger Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit Burger\XLTF-01-2017 Twin Falls, ID\docs\ELECTRICAL COMN Page 4 of 12 CHECK IECC-12.cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.2.3 HVAC equipment efficiency verified. ❑Complies see the Mechanical systems list for values. [ME55]2 j❑Does Not ❑Not Observable ❑Not Applicable C403.2.5. Demand control ventilation provided ❑Complies Exception: Spaces where the supply airflow rate minus 1 for spaces >500 sq.ft. and >25 j❑Does Not makeup air and minus outgoing transfer air is less than 1200 [ME59]1 people/1000 sq.ft. occupant density cfm. and served by systems with air side ❑Not Observable economizer, auto modulating outside ;❑Not Applicable air damper control, or design airflow >3,000 cfm. C403.2.7 HVAC ducts and plenums insulated. ❑Complies Requirement will be met. [ME60 Where ducts or plenums are installed ❑Does Not in or under a slab,verification may need to occur during Foundation ❑Not Observable Inspection. ❑Not Applicable C403.2.8. Piping Insulation exposed to weather ❑Complies Requirement will be met. 1 is protected from damage (due to sun, :❑Does Not [ME7]3 moisture, wind, etc.). ❑Not Observable j❑Not Applicable C403.2.8 ;Thermally ineffective panel surfaces of;❑Complies Exception: Requirement does not apply. [ME41]3 :sensible heating panels have j❑Does Not :insulation >= R-3.5. ❑Not Observable ❑Not Applicable C403.2.7 I Ducts and plenums sealed based on ❑Complies Requirement will be met. [ME10]2 :static pressure and location. ❑Does Not ❑Not Observable ❑Not Applicable C403.2.7. Ductwork operating >3 in. water ❑Complies Exception: Requirement does not apply. 1.3 :column requires air leakage testing. j❑Does Not [ME11]3 j❑Not Observable ❑Not Applicable C403.2.7. Ductwork operating >3 in. water ;❑Complies Exception: Requirement does not apply. 1.3 column requires air leakage testing. j❑Does Not [ME11]3 ❑Not Observable ❑Not Applicable C403.2.7. Ductwork operating >3 in. water ❑Complies Exception: Requirement does not apply. 1.3 column requires air leakage testing. :❑Does Not [ME11]3 ❑Not Observable ❑Not Applicable C403.3.1, !Air economizers provided where ;❑Complies Requirement will be met. C403.3.1. required, meet the requirements for :❑Does Not 1 design capacity, control signal, [ME62]1 ventilation controls, high-limit shut-off„❑Not Observable integrated economizer control, and ❑Not Applicable provide a means to relieve excess outside air during operation. C403.3.1, Air economizers provided where ❑Complies Requirement will be met. C403.3.1. required, meet the requirements for ❑Does Not 1 design capacity, control signal, [ME62]1 ventilation controls, high-limit shut-off, Observable integrated economizer control, and ❑Not Applicable provide a means to relieve excess outside air during operation. 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Habit Burger Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit Burger\XLTF-01-2017 Twin Falls, ID\docs\ELECTRICAL COMN Page 5 of 12 CHECK IECC-12.cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C408.2.2. ;Air outlets and zone terminal devices ❑Complies Requirement will be met. 1 :have means for air balancing. :❑Does Not [ME53]3 ❑Not Observable j❑Not Applicable C403.4.2 VAV fan motors >=7.5 hp to be driven ❑Complies Exception: Requirement does not apply. [ME66]2 :by variable speed drive, have a vane- I❑Does Not :axial fan with variable pitch blades, or j have controls to limit fan motor ❑Not Observable demand. ;❑Not Applicable C403.4.2 ;VAV fan motors >=7.5 hp to be driven ❑Complies Exception: Requirement does not apply. [ME66]2 :by variable speed drive, have a vane- :❑Does Not axial fan with variable pitch blades, or have controls to limit fan motor ❑Not Observable demand. ;❑Not Applicable C403.4.2 VAV fan motors >=7.5 hp to be driven ❑Complies Exception: Requirement does not apply. [ME 66]2 by variable speed drive, have a vane- ❑Does Not axial fan with variable pitch blades, or have controls to limit fan motor ❑Not Observable .demand. ;❑Not Applicable C403.2.6 Exhaust air energy recovery on ❑Complies [ME57]1 isystems meeting Table C403.2.6 :❑Does Not ❑Not Observable ❑Not Applicable C403.2.11 I Unenclosed spaces that are heated ❑Complies Exception: Requirement does not apply. [ME71]2 'use only radiant heat. j❑Does Not ❑Not Observable j❑Not Applicable Additional Comments/Assumptions: r1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Habit Burger Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit Burger\XLTF-01-2017 Twin Falls, ID\docs\ELECTRICAL COMN Page 6 of 12 CHECK IECC-12.cck Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.2. ;Automatic controls to shut off all ❑Complies Requirement will be met. 1 :building lighting installed in all j❑Does Not [EL22]2 buildings. ❑Not Observable j❑Not Applicable C405.2.1. Independent lighting controls installed ❑Complies Requirement will be met. 1 per approved lighting plans and all ❑Does Not [EL23]2 manual controls readily accessible and visible to occupants. ❑Not Observable ❑Not Applicable C405.2.1. Lighting controls installed to uniformly ❑Complies Requirement will be met. 2 reduce the lighting load by at least :❑Does Not [EL15]1 50%. ❑Not Observable UNot Applicable C405.2.2. Daylight zones provided with ❑Complies Requirement will be met. 3 individual controls that control the :❑Does Not [EL16]2 :lights independent of general area lighting. ❑Not Observable j❑Not Applicable C405.2. Sleeping units have at least one ❑Complies Exception: Requirement does not apply. [EL17] master switch at the main entry door :❑Does Not that controls wired luminaires and switched receptacles. ❑Not Observable ❑Not Applicable C405.2.2 Occupancy sensors installed in I❑Complies Requirement will be met. 2 required spaces. ❑Does Not [EL18]1 ❑Not Observable ❑Not Applicable C405.2.2. Primary sidelighted areas are ❑Complies Requirement will be met. 3 equipped with required lighting ❑Does Not [EL20]1 controls. ❑Not Observable ❑Not Applicable C405.2.2. Enclosed spaces with daylight area ❑Complies Exception: Requirement does not apply. 3 under skylights and rooftop monitors :❑Does Not [EL21]1 are equipped with required lighting controls. ❑Not Observable ❑Not Applicable C405.2.3 Separate lighting control devices for ;❑Complies Requirement will be met. [EL4]1 specific uses installed per approved I❑Does Not lighting plans. ❑Not Observable ❑Not Applicable C405.3 Fluorescent luminaires with odd ❑Complies Exception: Requirement does not apply. [EL19]3 numbered lamp configurations that :❑Does Not are within 10 feet center to center(if recess mounted) or are within 1 foot ❑Not Observable edge to edge (if pendant or surface :❑Not Applicable mounted)shall be tandem wired. C405.4 Exit signs do not exceed 5 watts per I❑Complies Requirement will be met. [EL6]1 face. j❑Does Not ❑Not Observable j❑Not Applicable C405.2.3 Additional interior lighting power I❑Complies Requirement will be met. [EL8]1 allowed for special functions per the j❑Does Not approved lighting plans and is automatically controlled and ❑Not Observable separated from general lighting. '❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Habit Burger Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit Burger\XLTF-01-2017 Twin Falls, ID\docs\ELECTRICAL COMN Page 7 of 12 CHECK IECC-12.cck 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Habit Burger Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit Burger\XLTF-01-2017 Twin Falls, ID\docs\ELECTRICAL COMN Page 8 of 12 CHECK IECC-12.cck Section # Final Inspection Complies? Comments/Assumptions & Req.ID C403.2.4. Heating and cooling to each zone is ❑Complies Requirement will be met. 1 controlled by a thermostat control. :❑Does Not [F147]3 Minimum one humidity control device per installed ❑Not Observable humidification/dehumidification '❑Not Applicable system. C403.2.4. Heating and cooling to each zone is I❑Complies Requirement will be met. 1 :controlled by a thermostat control. j❑Does Not [F147]3 Minimum one humidity control device ;per installed ❑Not Observable humidification/dehumidification ❑Not Applicable system. C403.2 Heating and cooling to each zone is ❑Complies Requirement will be met. 1 controlled by a thermostat control. ❑Does Not [F147]3 Minimum one humidity control device per installed ❑Not Observable humidification/dehumidification ;❑Not Applicable system. C403.2.4. ;Thermostatic controls have a 5 °F ❑Complies Requirement will be met. 2 deadband. :❑Does Not [F138]3 ❑Not Observable ❑Not Applicable C403.2.4. ;Temperature controls have setpoint �❑Complies Requirement will be met. 2 :overlap restrictions. ❑Does Not [F120]3 ❑Not Observable ❑Not Applicable C403.2.4. Each zone equipped with setback ❑Complies Requirement will be met. 3 controls using automatic time clock or ❑Does Not [F139]3 programmable control system. ❑Not Observable ❑Not Applicable C403.2.4. ;Automatic Controls: Setback to 55°F I❑Complies Requirement will be met. 3 (heat) and 85°F (cool); 7-day clock, 2- I❑Does Not [F140]3 ;hour occupant override, 10-hour ❑ backup Not Observable j ❑Not Applicable C403.2.4. Systems include optimum start ❑Complies Requirement will be met. 3.3 controls. ;❑Does Not [F141]3 ❑Not Observable ❑Not Applicable C403.2.4. Systems include optimum start ❑Complies Requirement will be met. 3.3 controls. ;❑Does Not [F141]3 ❑Not Observable ❑Not Applicable C403.2.4. Systems include optimum start ;❑Complies Requirement will be met. 3.3 controls. ❑Does Not [F141]3 ❑Not Observable ❑Not Applicable C408.2.5 Furnished HVAC as-built drawings ❑Complies Requirement will be met. 1 submitted within 90 days of system ❑Does Not [F17]3 acceptance. ❑Not Observable ❑Not Applicable C303.3 Furnished O&M manuals for HVAC ❑Complies Requirement will be met. C408.2 systems within 90 days of system ❑Does Not 3 acceptance. [F18]3 ❑Not Observable ❑Not Applicable 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Habit Burger Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit Burger\XLTF-01-2017 Twin Falls, ID\docs\ELECTRICAL COMN Page 9 of 12 CHECK IECC-12.cck Section # Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.5. An air and/or hydronic system ❑Complies Requirement will be met. 3 i balancing report is provided for HVAC :❑Does Not [F143]1 ;systems. ❑Not Observable ❑Not Applicable C408.2.3. HVAC control systems have been ❑Complies Requirement will be met. 2 tested to ensure proper operation, I❑Does Not [FI10]1 calibration and adjustment of controls. ❑Not Observable ❑Not Applicable C403.2.2 HVAC systems and equipment ❑Complies Requirement will be met. [F127]3 capacity does not exceed calculated I❑Does Not loads. ❑Not Observable ❑Not Applicable C408.2.5. Furnished as-built drawings for ❑Complies Requirement will be met. 1 electric power systems within 30 days :❑Does Not [F116]3 of system acceptance. ❑Not Observable j❑Not Applicable C303.3, :,Furnished O&M instructions for ❑Complies Requirement will be met. C408.2.5. systems and equipment to the '❑Does Not 2 building owner or designated [F117]3 representative. ❑Not Observable ❑Not Applicable C405.5.2 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [F118]1 lighting power is consistent with what :❑Does Not is shown on the approved lighting plans, demonstrating proposed watts ❑Not Observable are less than or equal to allowed ;❑Not Applicable watts. C408.2.1 ,Commissioning plan developed by ❑Complies Requirement will be met. [F128]1 registered design professional or :❑Does Not ;approved agency. Location on plans/spec: na ❑Not Observable ❑Not Applicable C408.2.4 Preliminary commissioning report ❑Complies Requirement will be met. [F129]1 completed and certified by registered :❑Does Not design professional or approved ❑Not Observable Location on plans/spec: na agency. :❑Not Applicable C408.2.5. Final commissioning report due to ❑Complies Requirement will be met. 4 building owner within 90 days of :❑Does Not [F130]1 receipt of certificate of occupancy. ❑Not Observable Location on plans/spec: na ❑Not Applicable C408.2.3. HVAC equipment has been tested to ❑Complies Requirement will be met. 1 ensure proper operation. ❑Does Not [F131]1 ❑Not Observable ❑Not Applicable C408.2.3. Economizers have been tested to ❑Complies Requirement will be met. 3 lensure proper operation. ❑Does Not [F132]1 ❑Not Observable ❑Not Applicable C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [F133]1 ensure proper calibration, adjustment, :❑Does Not programming, and operation. ❑Not Observable j❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Habit Burger Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit Burger\XLTF-01-2017 Twin Falls, ID\docs\ELECTRICAL COMN Page 10 of 12 CHECK IECC-12.cck 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Habit Burger Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit Burger\XLTF-01-2017 Twin Falls, ID\docs\ELECTRICAL COMN Page 11 of 12 CHECK IECC-12.cck Project Title: Habit Burger Report date: 09/05/17 Data filename: N:\2017\Lingle Design Group\Habit Burger\XLTF-01-2017 Twin Falls, ID\docs\ELECTRICAL COMN Page 12 of 12 CHECK IECC-12.cck & AND M. MEN PROJECT DESCRIPTION: FIRE SPRINKLER,ALARM,AND KITCHEN FIRE theSHEET INDEX ANGLE MAS. MASONRY SUPPRESSION SYSTEM DRAWINGS(TYPE-I HOOD), o AT MATL. MATERIAL This project is a tenant improvement for a casual dining restaurant in a ARE TO BE REVIEWED UNDER A DEFERRED CENTERLINE MAX. MAXIMUM new commercial buildingspace. . SHEET/ TITLE REV H DAMETER M.B.CHANNEL MEDICINE CABINET Regular building constrution is underase crate ennit. SUBMITTAL,AND FILED SEPARATELY \?SEpIgRCyi��i M.C. ARCHITECTURAL h PERPENDICULAR MECH. MECHANICAL g P P U: CARLL•••F MEMB. MEMBRANE 'n =J: = uINGE - P PLATE OR PROPERTY LINE MFR. MANUFACTURER The tenant exterior scope of work will include new signage,seating, EXTERIOR SIGNAGE TO BE FILED G100 COVER SHEET = _ # POUND OR NUMBER M H umbrellas,gas heaters lighting,patio railing and new drive-thru signage. _ _5 MANHOLE A.B. ANCHOR BOLT MIN. MINIMUM The Landlord ovements,unerg scoperound of work will ewhee anyers planting UNDERASEPARATE PERMIT SUBMITTAL 0105 ARCHITECTURAL SITE PLAN 1 N92319 MIR. MIRROR improvements,underground utlitites to new heaters,and new concrete CANYON PARK WEST A.C. ASPHALT CONCRETE MISC. G106 DRIVE-THRU SIGNAGE PLAN .••'; ✓" ACOUS. ACOUSTICAL MISCELLANEOUS exterior patio. �ii ADD. ADJUSTABLE M D. MOUNTED OPENING 1106.1 DRIVE-THRU SIGN FOOTING DETAILS / I t AGGR. AGGREGATE The interior scope of work will include new nonbearin9 partitions, 192 5 F I L L M O R E STREET G110 CODE ANALYSIS AND LIFE SAFETY PLAN 1 MTL. METAL 1 INTERIOR ELEVATION ALUM. ALUMINUM MULL. MULLIION installation of tenant equipment&furnishings,plumbing,mechanical,and ANOD. ANODIZED electrical. LOCATION ON SHEET TWIN FALLS I D 83301 G120 ACCESSIBILITY DETAILS APPROX.APPROXIMATE ARCH. ARCHITECT NN) NORTH The following items will be under a separate permit: 4 A 2 1 G130 RESPONSIBILITY MATRIX ASPH. ASPHALT NAT. NATURAL - Environmental Health Department-Food Service Facility SHEET ELEVATION IS DRAWN ON A100 GENERAL RED.AND CONDITIONS BD. BOARD N.I.C. NOT IN CONTRACT - Commercial Exhaust Hood BURGER GRILL STORE #249 NO.OR#NUMBER A110 SPECIFICATION SHEET 1 BET. BETWEEN NOM - Hood Fire Suppression System NOMINAL VIEW SHOWN ut BITUM. BITUMINOUS NR, - Building/Tenant Signage BLDG. BUILDING NOISE REDUCTION A120 SPECIFICATION SHEET 2 - w N.T.S. NOT TO SCALE Building Fire Alarm&Sprinkler System Modifications m -rn BLKG. BLOCKING CP v BM. BEAM DETAIL REFERENCE A200 FLOOR PLAN o B.N. BOUNDARYNAILING O/ OVER PROJECT NOTES: BOT. BOTTOM OBS. OBSECURE LOCATION ON SHEET A210 REFLECTED CEIUNG PLAN [� m m O.C. ON CENTER 1.Tenant shall take care when removing concrete slab and shall dowel SHEET WHERE DETAIL IS DRAWN ON rs f ut B.U.R. BUILT UP ROOFING 9 1 A220 CEILING COORDINATION PLAN - OOF OUTSIDE DIAMETER(DIM.) into existing slab to tie new sections together.All required rebar qt m r ^m OFFICE CAB. CABINET O.H.M.S. including dowels to meet landlord's required specifications.Proper A230 FINISH PLAN ow z L i m 7 C.B. CATCH BASIN OVAL HEAD MACHINE SCREW 3 w C.B. CEMENT O.H.W.S.OVAL HEAD WOOD SCREW compaction of any saw cut to meet 90%or better and concrete shall A240 GRAPHICS PLAN CER. CERAMIC Opp. OPENING G placed at a minimum of 4"thick. z ut x u_ C.I. CAST IRON Opp. OPPOSITE 2.GC must use the Landlord's Fire Sprinkler - ip A250 ENLARGED TOILET PLAN a C.J. CONTROL JOINT OZ' OUNCE Contractor, and the Landlord's Roofer ROOM NUMBER e CLG. CEILING p.O,F, for any applicable work. a.,y _ !`. A260 FURNITURE AND EQUIPMENT PLAN POUNDS PER CUBIC FOOT 00 Project Site o CLO. CLOSET PERIM. 3.Tenant shall contact Dig Alert for location of existing utilities when s oe A270 PATIO PLAN 1 CLR. CLEAR P LAM PERMITER installing grease interceptor. ROOM��ROOM NAME ; C.M.U. CONCRETE MASONRY UNIT PLAg PLASTIC LAMINATE q An asphalt section removed shall be compacted to 90%or greater A300 PARTITION TYPES C.O. CLEAN OUT PLYWD PLASTER Y P P 9 ,.e� PLYWOOD and the existing asphalt section shall be replaced.GC to provide SECTION CUT COL. COLUMN A400 INTERIOR DETAILS COMB. COMBINATION P.O.C. POINT OF CONNECTION reports of lifts and compactions to the owner at turn over for LOCATION ON SHEET '� COMP. COMPRESS ED ION PR' PAIR verification. A410 INTERIOR DETAILS ( )(ION) PRCST. PRE-CAST 1 SHEET WHERE SECTION IS DRAWN CONIC. CONCRETE P,r.D, 5.Tenant shall use a urinal that saves approx.40,000 gallons of water CONN. CONNECTION P.T.D.F PAPER TOWEL DISPENSER per year. Al A500 INTERIOR ELEVATIONS CONT. CONTINUOUS P.T.DR COMBINSTION PAPER TOWEL 6.If Tenant does not use existing outlets provided by the Landlord, A510 EXTERIOR ELEVATIONS CONSTR.CONSTRUCTION DISPENSER AND RECEPTACLE Tenant shall wire nut and cap outlets as required by the 2014 NEC. VIIIIIIiiiL Ell CONTR. CONTRACTDR) PTN. PARTITION 7. 'This Building must be equipped with an automatic fire extinguishing 1 KEYED NOTE - p STRUCTURAL CPT. CARPETED) P.S.F. POUNDS PER SQUARE FOOT system complying with NFPA-13.The sprinkler system shall be "- CTSK. COUNTERSINK P.T.R. PAPER TOWEL RECEPTACLE approved b the Fire Department P.V.C. Y p prior to installation"Plans for POLYVINYL CHLORIDE fire protection systems shall be submitted to the local Fire � 5100 STRUCTURAL ROOF PLAN 1 D. DEEP PVMT. PAVEMENT proposed P y # SWALL YMBOL DBL. DOUBLE Protection District for review and approval PRIOR to installation or SYMBOL 5200 DETAILS DEPT. DEPARTMENT OT. QUARRY TILE work being started. DIET. DETAIL QTR. QUARTER 8."Sprinkler system to be approved by Fire Department prior to ' D.F. DOUGLAS FIR installation."Plans for modifcationsto existli f fire protection system DIA. DIAMETER R. RISER shall be submitted to the Fire Protection District for review and DIM.. DIAGONAL RA RETURN AIR REVISION MARK DIM. DIMENSION RAD. RADIUS approval PRIOR to installation or work being started. MECHANICAL DISP. DISPENSER RD. 9.All the work such as site lighting,trash enclosures,site drainage,drive ROUND DK. DARK R.D. ROOF DRAIN aisles,curb ramps and accessible parking will be completed as part of MEP100 MECH/ELEC/PLUMB ROOF PLAN 1 DN. DOWN REF. REFERENCE the building shell package and will be existing prior to commencement (((���QQQ�\\\DR. DOOR REFR. REFRIGERATOR of Tl construction. \ '`/ N M200 MECHANICAL FLOOR MICE MECHANICAL SPECIFICATIONSA 1 DS. DOWNSPOUT REG. REGISTER Imo/DWG. DRAWING REINF. REINFORCED ENERGY NOTES: DWR. DRAWER REQ. REQUIRED M300 MECHANICAL SCHEDULE 1 REM. GRID LINES VICINITY MAP EMOVE T (E) EXISTING RESIL. a.The builder shall provide to the building owner at occupancy M400 MECHANICAL DETAILS RESRILIEN _ _ E. EAST RET. maintenance information for all features,materials.components and RETAINING EA. EACH REV. manufactured devices that required routine maintenance for efficient M500 HOOD DRAWINGS E.J. EXPANSION JOINT R.G. REVISION(S)/REVISED q Fire Department Health Department ELEC. ELECTRICAL R.H.M.S. ROUGH GRADE operation.This information shall also be provided to the person(s) 0510 HOOD DRAWINGS ELEV. ELEVATOR OR ELEVATION R.H.W.S.ROUND HEAD MACHINE SCREW responsible for maintaining the feature,material component or ROUND HEAD WOOD SCREW mechanical device installed in the building.See note 2 on At 00. M520 HOOD DRAWINGS E.N. EMERGENCY RM. ROOM E.N. EDGE NAILING R.O. b.The builder shall provide to the building owner at occupancy N NORTH ARROW ROUGH OPENING M530 HOOD DRAWINGS ENCL. ENCLOSURE RWD. maintenance information for all features,materials,components and REDWOOD E.P. ELECTRICAL PANELBOARD manufactured devices that required routine maintenance for efficient EQ. EQUAL S. SOUTH operation.Required routine maintenance actions shall be clearly At Shall be the responsibility Of the general M540 HOOD DRAWINGS EQUIP. EQUIPMENT S.A. SUPPLY AIR stated and incorporated on a readily accessible label.The label may contractor to insure that all deferred EST. ESTIMATE S.C. SOLID CORE be limited to identifying,b title and/or ublication number,the E.W.C. ELECTRICAL WATER COOLER y r submittals required by the fire department S.C.D. SEAT COVER DISPENSER operation and maintenance manual for that articular model and a PLUMBING EXCA. EXCAVATE P P type PROJECT DIRECTORY 110 SCHED. SCHEDULE have been approved by the state prior to the EXH. EXHAUST of feature,material,component or manufactured device. EXIST. EXISTING S.D. STORM DRAIN/SOAP DISPENSE c.All systems,equipment and/or building components shall comply with installation Of a fire alarm and/or fire sprinkler SECT. SECTION P100 PLUMBING SPECIFICATIONS EXTEXP. EXTERIOREXPANSIO S.F. SQUARE FEET applicable manufacturer provisions and installation provision of system.It shall also be the responsibility of P200 SANITARY/GREASE WASTE PLAN SH. SHELF ASHRAE 90.1-2007. the general Contractor t0 verity that all SHWR. SHOWER d.Manufactured fenestration products and exterior doors shall have air TENANT: P210 WATER AND GAS SUPPLY PLAN F.A. FIRE ALARM MPE ENGINEERS: appropriate testing and/or Inspections have FA.FIN. FACTORY FINISH SHT. SHEET area tion rates not exceeding 0.3 cfmlffi of window area and door The Habit Burger Grill Aedifica Case Ln neers Inc. P220 FLOOR DRAIN ROUGH-IN PLAN F.B. FLAT BAR SHTG SHEATHING area 17320 Red Hill Ave. Suite 140 9' been performed before covering or calling for SIM. SIMILAR 796 Merus Court F.D. FLOOR DRAIN e.Joints and other openings in the building envelope that are potential Irvine, California 92614 a final inspection. paoo PLUMBING RISERS SL. SLIDING St. Louis, MO 63023 FDN. FOUNDATION sources of air leakage shall be caulked,gasketed,weatherstripped,or P: 949.851.5881 Jeff Leeker P410 PLUMBING DETAILS F.E. FIRE EXTINGUISHER SMACNA S.M.S. SHEET METAL SCREW otherwise sealed to limit infiltration and exfltration. F: 949.852.4650 F.E.C. FIREEXTINGUISHER CABINET P: 636-349-1600 F.F. FINISH FLOOR S.N.D. SANITARY NAPKIN DISPENSER f. 80 dog.The heat watefthe water heater storage tank surface,be less esthan .5 an W: www.habitburger.com E: jleeker@aedificc.com F.G. FINISH GRADE S.N.R. SANITARY NAPKIN RECEPTACLE g0 deg.F.water-air temperature difference shall be less than 6.5 F.H. FIRE HYDRANT SPEC. SPECIFICATION Btu/hr per square foot ARCHITECT/MPE ENGINEERS: g7RUC7URAL ENGINEERS: ELECTRICAL F.H.C. FIREHOSE CABINET SQ. SQUARE g.Insulation shall be certified by the manufacturer as compliantwith the Lingle Design Group S S. STAINLESS STEEL Aedifica Case Engineers Inc. Approval Stamp Approval Stamp&Signature F.H.M.S. FLAT HEAD MECHINE SCREW Quality Standards for Insulating Material,ASHRAE 90.1-2007.N/A 158 WEST MAIN STREET F.H.W.S.FLAT HEAD WOOD SCREW STL. STEEL 796 Merus Court E100 ELECTRICAL SPECIFICATION SHEET STOR. STORAGE not part of Tl scope. LENA, IL 61048 St. Louis, MO 63023 FIN. FINISH STA. STATION h.Urea formaldehyde foam insulation may only be used in exterior side DREW GOEKE FIXT. FIXTURE Jeff Leeker E200 LIGHTING PLAN AND NOTES STD. STANDARD walls,and requires afour-mil-thick plastic polyethylene vapor barrier P: 815-369-9155 E201 LIGHTING FIXTURE SCHEDULE J F.L. FLOW LINE P: 636-349-1600 FLASH. FLASHING STRUC. STRUCTURAL between the urea formaldehyde foam insulation and the interior W DREWGO ledesi n—uri SIGN.COM E: Leker@oedifica.com J FLEX. FLEXIBLE SUSP. SUSPENDED space.N/A not part of Tl scope. W: www.lingledesign.com / E210 POWER PLAN NOTES SYM. SYMMETRICAL FUR. FLOOR I. All insulating material shall be installed in compliance with the flame LANDLORD: E211 FIRE ALARM REFERENCE PLAN 1 FLUOR. FLUORESCENT s read ratio and smoke density requirements of the IBC.N/A not RESTAURANT DESIGN CONSULTANT: F.N. FIELD NAILING T TREAD p g ty q WOODBURY CORPORATION F.O. FINISH OPENING T.&SOT.TOP&BOTTOM part of Tl scope. TriMark Raygal Foodservice 2733 E. PARLEY WAY- STE 300 E300 ONE LINE DIAGRAM AND PANEL SCHEDULES F.O.C. FACE OF CONCRETE T.B. TOWEL BAR j. All heating and/or cooling systems shall have an automatic thermostat Design, Equipment and Supplies SALT LAKE CITY, UT 84109 L1J F.O.F. FACE OF FINISH T.C. TOP OF CURB with clock mechanism or other setback mechanism as approved that 2801 McGaw Avenue JEFF STOKES E400 ELECTRICAL DETAILS w F.O.M. FACE OF MASONRY T.C.B. TOP OF CATCH BASIN shuts the system off during peak periods of non-use and that allows Irvine, CA 92614 801-485-7770 E410 ELECTRICAL DETAILS r F.O.S. FACE OF STUDS T.G. TOP OF GRADE the building occupant to automatically set back the thermostat set Mike Brady FPL. FIREPLACE TEL. TELEPHONE points for at least two periods P: 949.474.1000 E500 ELECTRICAL SITE PLAN W TER. TERRAZZO FT. FOOT NG FEET within 24 hours. E: mbrody@trimarkusa.com W FTG. FOOTING TH. TONGUE AND GROOVE W: trimarkusa.com FURR. FURRING TH. THICK PUT. FUTURE T.O. TOP OF Se Lll LI..I T.P. TOP OF PAVING Lr- GA. GAUGE T.P.D. TOILET PAPER DISPENSEER - �'' rIF � I'a s m Q �r GALV. GALVANIZED TS TUBULAR STEEL GENERAL REQ. & CONDITIONS DRAWING SYMBOLS LEGEND G.B. GRAB BAR T.S. TELEVISION o =Z G.C. GENERAL CONTRACTOR 0 GL. GLASS T.W. TOP OF WALL GENERAL BUILDING DATA NOTE:SEATING STORAGE SQUARE FOOTAGE BREAKDOWN o LLI>_ J GND. GROUND TY R TYPICAL / 0 Z � Z GR. GRADE IS FOR OWNER REFERENCE ONLY.THE FOLLOWING o `� FOOD SERVICE SHEETS-FOR REFERENCE ONLY G.S.M. GALVANIZED SHEET METAL U.O.N. UNLESS OTHERWISE NOTED Construction Type:Type V-B,Fully Sprinklered NUMBERS ARE NOT CODE RELATED. U m GYP. GYPSUM UR. URINAL F5010 COVER SHEET H. HIGH Gross Floor Area of Habit Tenant Space:3,061 SF SEE LIFE SAFETY PLAN ON SHEET G110 FOR CODE a VCT. VINYL COMPOSITION TILE F5200 KITCHEN PLAN H.B. HOSE BIB CALCULATIONS. �fp` VERT. VERTICAL Habit Occupancy Group:A-2 `- FS205 EQUIPMENT SCHEDULE H.C. HOLLOW CORE OR VFY. VERIFY SQUARE FOOTAGE BREAKDOWN: HANDICAPPED V.G. VERTICAL GRAIN HER. HEADER V.G.D.F. VERTICAL DRAIN DOUGLAS FIR CODEANALYSIS-See sheet G110 for Occupant Load/Exiting o o F5210 PLUMBING PLAN KITCHEN/B.O.H. =864 Il p n (r FS220 ELECTRICAL PLAN HDWD. HARDWOOD VEST. VESTIBULE DINING = 1334 1s F5230 BUILDING CONDITION PLAN HDWR. HARDWARE V.T.R. VENT THROUGH ROOF o w H.M. HOLLOW METAL PROJECT STATISTICS MISC. RESTROOMS = 684 FS500 EQUIPMENT KEY ELEVATIONS _ HORIZ. HORIZONTAL WSCT. WAINSCOT - - - - HR. HOUR W.F.B. WIDE FLANGE BEAM HT. HEIGHT W. WEST/WIDE/WOMEN F5510 EQUIPMENT KEY ELEVATIONS o 0 HVAC HEATING VENTILATING 8 W/ WITH TOTAL INTERIOR SF: 2882 X X X AIR CONDITIONING W.C. WATER CLOSET This Project shall comply with the following codes: PATIO SPACE SF: 380 I.D. INSIDE DIAMETER(DIM.) WD. W TOTAL AREA SF: 3262 I.E. INVERT ELEVATION WDW. WINDOW *2015 International Building Code INSUL. INSULATION W.H. WATER HEATER SEATING/ TABLE COUNTS: Il Il INT. INTERIOR WO WITHOUT *2014 National Electrical Code INV. INVERT WATERPROOF INTERIOR: W.R. WASTE RECEPTACLE *2015 International Mechanical Code AR71A THE HABIT JAN. JANITOR VWR WATER RESISTANT ACTUAL SEAT COUNT: TABLE COUNT: SHE k' co JST. JOIST WEIGHT 56 19 Building Plans have JT. JOINT W.W.F. WELDED WIRE FABRIC *2015 International Plumbing Code EXTERIOR: ,n reviewed and apt' W K TCHEN D. KILN DRIED KIT. *2015 Internationalal Energy Conservation Code ACTUAL SEAT COUNT: TABLE COUNT: K �� 18 8 e_�Construction Sub' KO KNOCKOUT `2015International Fire Code 1 L. LENGTH/LONG Field Inspection LAB. LABORATORY *20151ntemational Fuel Gas Code LINEAL STORAGE BREAKDOWN: o LAM. LAMINATE N) STANDARD FLOOR SHELVING: N LAY. LAVATORY *2009 ANSI AT17.1 Standard for Accessible and Usable Building and Facilities �a a#: 13 of 70 m (V L.L. LANDLORD 2'-0" DEEP= 36 L.F. g LT. LIGHT' NOTE:FOR ADDITIONAL SITE INFORMATION SEE LVR. LVR. *City ofTWIN FALLS,ID OVERHEAD STORAGE SHELVING: mow'" EXISTING ARCHITECTURAL SITE PLAN ON SHEET G105 MOUNTED 7'-0" HIGH x Date, 10/10/17 1'-2" DEEP= 5.0 L.F. G 100 ABBREVATIONS APPLICABLE CODES SEATING/STORAGE COUNT LOCATION MAP SHEET INDEX 9/21/17 REV 1 LANDLORD TO INSTALLAND PAVEMENTDETECTION E PER NUFACTUR ND MANUFACTURER DRIVE-THRU PREVIEW BOARD. RECOMMENDATIONS. HABIT G.C.TO INTERCEPT LOOP AND COMPLETE FINAL CONNECTIONS. SEE COORDINATE WITH SIGN VENDOR. U: CARLL :Fni DETAIL 3/G106 FOR MORE INFORMATION SEE SHEET 106.1 FOR FOOTING _=+; LINGLE REQUIREMENTS o 5 o AB-2319 e EXISTING GREASE '•INTERCEPTOR BY �4• - LANDLORD - I 10 10 DRIVE THRU CLEAR BAR. COORDINATE WITH SIGN ■ , ■ A VENDOR. SEE SHEET 106.1 - FOR FOOTING REQUIREMENTS Fffw � ma --------- --; --: —� -----;------ ,---------- -o m� , , ■ - � - r- min o r 71 DRIVE-THRU ORDER a BOARD. COORDINATE WITH EXISTING FIRE SIGN VENDOR. SEE SHEET RISER ROOM 106.1 FOR FOOTING EXISTING GAS /� 0 REQUIREMENTS METER BANK. CONFIRM BOLLARD -��--- PROTECTION `, PROVIDED BY I LANDLORD PER FIRE DEPARTMENT z z REQUIREMENTS • HABIT DRIVE THRU ENTER SIGN. TRASH ENCLOSURE ■ COORDINATE WITH SIGN BY LANDLORD ■ z z VENDOR. SEE SHEET 1p i - i ¢ a ° 106.1 FOR FOOTING a a REQUIREMENTS LANDLORD TO INSTALL DRIVETHRU ■ ■ BURGER $Ind a not pp DETECTION LOOP AND PAVEMENTT PER `.... ■ approved.MANUFACTURER RECOMMENDATIONS. ...... J J g it oval.Separate HABIT G.C.TO INTERCEPT LOOP AND 2.882 S.F /// /// permit required for all signage. COMPLETE FINAL CONNECTIONS.SEE . DETAIL 2/0106 FOR MORE - INFORMATION Q Q IL I I - - - MINN ilif - - - - 11 1 1 11�1�11 11�1�11 11�1�11 11�1�11 11�1�11 11�1�11 11�1 777 L.F.TO / PUBLIC WALK 7 /' /" VA ACCESSIBIE - F ESTANDI G ST NING FREE ST NDING SIGN ■ � � SI N ■ ■ EXISTING ACCESSIBLE PATH OF TRAVEL-VERIFY PATIO AREA BY COMPLIANCE WITH NOTES 35 L.F.TO DRIVE THRU EXIT SIGN. LANDLORD AND LOCAL REQUIREMENTS H.C. PARKING Planning and zonir COORDINATE WITH SIGN 380 S.F. VENDOR. SEE SHEET 106.1 FOR FOOTING REQUIREMENTS J C, LU III cli WCIO q4- � w � Irn w F M H H Y LU o W m¢ O vi U EXISTING PARKING SPACES AND AISLES- =Z J VERIFY COMPLIANCE WITH NOTES AND W> J LOCAL REQUIREMENTS Z � Z H U �' Im al EXISTING ARCHITECTURAL SITE PLAN SITE PLAN GENERAL NOTES: UILDING SCALE 3/32' -0 1. GENERAL CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS OF CURRENT SOILS REPORT.(COMPLETED WITHIN THE PAST 6 MONTHS). - z 2. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON DRAWINGS FOR CONFLICTS PRIOR TO CONSTRUCTION. THE J CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. _ 3. MINIMUM 12"HIGH ADDRESS NUMBERS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR AT THE SYMBOLS LEGEND: W FRONT ENTRANCE AND SERVICE ENTRANCE OF THE STORE PER TENANT REQUIREMENTS. FINAL DETERMINATION ON SIZE, This site pion not raVl2Wed Or approved for construction. COLOR AND EXACT LOCATION MAY BE ENFORCED BY GOVERNMENTAL AUTHORITIES. Jab site plans for Permit#17-0983 contain approved site work. D.A. ACCESSIBLE PATH ^^ J p pp 4. ANY DAMAGE BY GENERAL CONTRACTOR OR SUB CONTRACTOR TO EXISTING ASPHALTIC PAVEMENT AND/OR EXISTING Q LANDSCAPING SHALL BE REPAIRED AT NO COST TO THE OWNER OR TENANT. 5. GENERAL CONTRACTOR TO PROVIDE ALL GOVERNMENTAL REQUIRED SIGNAGE NECESSARY FOR CERTIFICATE OF OCCUPANCY(FIRE LANE SIGNAGE,"DO NOT BLOCK DOOR"ETC.). 0 0 INDICATES LIMITS OF CONSTRUCTION V 6. GENERAL CONTRACTOR SHALL VERIFY ALL ON SITE CONDITIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES W OR OMISSIONS PRIOR TO CONSTRUCTION.(THIRD PARTY INSPECTOR TO VERIFY ADA PARKING AND SIDEWALK REQUIREMENTS) _. 7. ACCESSIBLE ROUTE SLOPE NOT TO EXCEED 1:20 WITH A CROSS SLOPE NOT TO EXCEED 1:50 o 8. REFER TO SHEET ES100 FOR ADDITIONAL SITE INFORMATION = Q N G105 \�pOAT�p1AR/"I Signage not approved. Separate permit required for aII signage. z C)?5 CAAL L•:Fp LINGLE NOTE:REFERENCE ELECTRICAL DRAWINGS&SIGNAGE SHOP DRAWINGS FOR AB-�319 e DETECTOR LOOP INFORMATION&INSTALLATION INSTRUCTIONS COUPLING FOR L•• 1/2"PVC TUBING CENTERLINE TO ALIGN WITH CENTERLINE OF SPEAKER POST/DRIVE THRU \0 WINDOW CURB I L 7 _ w �m ma p � ❑ 1/2'PVC ❑ �o m m ` p TUBING f N i _ .... i z m x J G106 _ ____________ _4- _ --- ° . e ° REFERENCE ONLY °-e o p, - \ __ _ MAINTAIN 3'OF CLEARANCE ON ALL SIDES FROM REBAR,WIRESCREEN, SPEAKER POST L -- 6-7" - REINFORCING BARS,ELECTRICAL CABLE AND METAL OBJECTS STUB DETECTOR LOOP 5 CONDUIT®SPEAKER POST. DETECTOR LOOP PLAN DETAIL FEE ELECTRICAL PUN FOR ADDITIONAL INFORMATION a b N N VEHICLE A DETECTOR LOOP _ NEW PAVEMENT TO MATCH EXISTING POWER CONDUIT FROM INSIDE BUILDING SEE a ENLARGED PICK-UP WINDOW ::: ;:: .'.„;:.::;} s , `.. :.:` <` ELECTRCONDUIT P FOR 6 I ��:+ '':; � CONDUIT PLACEMENT SCALE 1/4'-1-0' DATA CONDUIT FROM LOOP SUPPORTS �'•?.'I: INSIDE BUILDING SEE a ENLG PREVIEW BOARD ;. , ELECTRICAL FQR ca"oulT PLACEMENT SCALE 1'1/4"= -O" A-DETECTOR LOOP SECTION @ MENU BOARD REFERENCE ONLY EXTERIOR WALL OF BUILDING 3 VEHICLE DETECTOR LOOP Yz"EXPANSION MATERIAL G106 NEW PAVEMENT TO MATCH EXISTING STUB CONDUIT IN DRIVE THRU Y AREA,SEE ELECTRICAL FOR T..> ......;... .'• :.:. % CONDUIT PLACEMENT ..*:. '. STAB ON GRADE 5 LOOP SUPPORTS •'.•F....�:i:�L� SEE ARCHITECTURAL DRAWINGS FOR INTERIOR DETAILS ,a y B-DETECTOR LOOP SECTION @ DRIVE THRU WINDOW =Tj 7 4„ - q 4'-4' a� SECTION DETAILS DETECTOR LOOP IN CONCRETE Ia> 9 l SCALE 3/4"=1'-0" B'-0" _ DETECTOR LOOP CENTERED IN NEW PAVEMENT(MATCH NEW TO EXISTING) NOTE:REFERENCE ELECTRICAL DRAWINGS&SIGNAGE SHOP DRAWINGS 36'MIN CLEARANCE FOR WIRE MESH, FOR DETECTOR LOOP INFORMATION&INSTALLATION INSTRUCTIONS IAND ANY OTHER METAL REINFORCEMENT WITHIN CONCRETE - +/- Planning 10'-0° EXTERIOR WALL OF BUILDING EL O L011 a h"EXPANSION MATERIAL -- -- -- --------- - - - -------- ---- 10'CURB STUB CONDUIT IN DRIVE THRU EXISTING PAVING TO REMAIN _ AREA,SEE ELECTRICAL FOR CONDUIT PLACEMENT (U SLOPE,SEE CML J a ..fie:. a SLAB ON GRADE W a� ENLARGED ORDER BOARD -i-i-i I=I= =III w 5 -I I=1 IJ I-ITT=ITT=ITT-I =1 . SCALE: 1/4°-f-HO' a T ENLG EXIT SIGN COMPACTED SUB GRADE,SEE CIVIL DRAWINGS CONCRETE FOOTING,SEE STRUCTURAL SCALE 1/4"=1'-0" 11J 11=III=T=II FOR REINFORCEMENT CONNECTION TO M CID LOOP PAD Y W in W m¢ O vi U an SECTION * DETECTOR LOOP IN CONCRETE PAD AT DRIVE THRU WINDOW w} J Lt KEYED NOTES NDICATED BY SYMBOL O SCALE: 3/4°-T-O' Urn O NEW HEIGHT CLEARANCE BAR BY SIGNAGE VENDOR UNDER SEPARATE PERMIT. SEE DETAIL 2/3106.1 FOR GENERAL FOOTING REQUIREMENTS NOTE:REFERENCE ELECTRICAL DRAWINGS&SIGNAGE SHOP DRAWINGS O PREVIEW MENU SIGN BY SIGNAGE VENDOR UNDER SEPARATE PERMIT. SEE DETAIL FOR DETECTOR LOOP INFORMATION&INSTALLATION INSTRUCTIONS 4/G106.1 FOR GENERAL FOOTING REQUIRMENTS DETECTOR LOOP CENTERED IN NEW PAVEMENT(MATCH NEW TO EXISTING) SPEAKER POST O VOICE BOX AND CANOPY BY SIGNAGE VENDOR UNDER SEPARATE PERMIT;(1)INTEGRAL 36"MIN CLEARANCE FOR WIRE MESH, FOOTING SERVES BOTH ITEMS. SEE DETAIL 3/G106.1 FOR FOOTING REQUIREMENTS REBAR AND ANY OTHER METAL REINFORCEMENT WITHIN CONCRETE T/-10'-0" STUB DETECTOR LOOP CONDUB 0 SPEAKER POST. SEE ELECTRICAL - w ® MENU SI MIT GN BY SIGNAGE VENDOR UNDER SEPARATE PER . SEE DETAIL 3/3106.1 FOR 6°CURB SITE PLAN FOR ADDITIONAL INFORMATION _ FOOTING BY LANDSCAPING/GREEN SPACE 3 4 O DETECTOR LOOP PROVIDED BY HABIT,INSTALLED BY LANDLORD TEAM-SEE 1 G106 EXISTING PAMNG TO REMAIN Q O / —_ POWER CONDUIT _ Z 8 © 'WELCOME TO THE HABIT'SIGN BY SIGNAGE VENDOR UNDER SEPARATE PERMIT. SEE n' SLOPE,SEE CIVIL TO BUILDING SEE ELECTRICAL FOR I I I n. • = CONDUIT PLACEMENT N DETAIL 1/3106.1 FOR FOOTING REQUIRMENTS n Oj THAN YOU/DO NOT ENTER SIGN BY SIGNAGE VENDOR UNDER SEPARATE PERMIT. i0" a ° .a SEE DETAIL 1/G106.1 FOR FOOTING REQUIREMENTS a II II.I O8 LANDLORD TO RE-PAVE OVER LANDLORD INSTALLED LOOP DETECTOR. REFERENCE —_ _ _ •;� ° I II DATA CONDUIT TO BUILDING SEE r — DETAIL 1/G106. L, ll l T ,L I I T, III I _I I III, III I I-I I, I I I I I I, ,1I I "" ELECTRICAL w SIGNAGE GENERAL NOTES COMPACTED SUB GRADE,SEE CIVIL DRAWINGS a 0 A.ALL SIGNAGE AND ASSOCIATED FOOTINGS DESIGNED AND SUBMITTED UNDER SEPARATE PERMIT-ALL N O NOTED SIZES ON THIS SHEET TO BE SUPERCEDED BY ANY DIFFERENCES IN SIGNAGE SHOP DRAWINGS. a SECTION aDETECTOR LOOP IN CONCRETE PAD AT MENU BOARD_ m N J a4 ENLG ENTRY AND CLEARANCE BAR DETAIL B.G.C.TO IN ALL ALL FOOTINGS AND PROVIDE POWER/DATA IN CONDUITS AS REQb.FOR SIGNAGE;REF. w w z ELECTRICAL DWG'S.AND SIGNAGE SHOPS. SCALE 3/4°-1'-0" b^i O LLI SCALE: 1/4'=T-O' C.G.C.TO VERIFY ALL FOOTING SIZES AND EXISTING CURB LOCATIONS BEFORE INSTALLATION OF FOOTINGS G 106 AND ROUTING OF POWER/DATA CONDUIT. TO XSTRONG \\p\11111II111f//ppii SCH.80 PIPE +I` 8'-0' r-w .�'- CANOPYBYSION 14 — �♦ f�0 ARO �i�� 2'-0.�k. ,,� MANUF. ",I 0.0.=2.38' �.�5...........hi�!G J' f0-0 'P r o § 0.278 Off' CARLL - q LINGLE t-1_ _ _ 5^STD.PIPE ••'•••' ,• _ 3'x1"#3is O.D.=5.56" ... .. �•• CONNECTION BY ��� � 1=0.258' Ax4x'/<' SIGN MANUFACTURER y 4 SO.HSS 3z3.Y.' g oi• #4@4'TOP 32' Sa HSS N �— CONCRETE PAD REMAINDER @ 12^ 3•STD.PIPE O.D.-3.50' (BV OTRERS) BaiS VERT.BARS 1=0218' br - fj z rd o _ w 2 nFRONT IBLEVATION �m ma o a• Zo �4•TOP 3r '+�`- m J N $, I'1 14, r tit w - � #304'TOP 24^ ,�4 REMAINDER®12' SLOTTED �• REMAINDER 12' b#8 VERT.BARS .1� HOLES 4 ' O 0 FOR ELECTRICAL z u7 x w #3@4-D.C. """ 4-!FS VERT.BARS -'It— 5•#5 VERT.BARS - Y •B�� 2'�"0 y o ° ' 1'•B'9 SIDE ELEVATION 'i 3'16 J a FRONT ELEVATION Ll arfe • ELEVATIONFRONT �'---' 3^B HOLE 0 0 1�O / FOR ELECTRICAL. W1(4 xY,STL.PLATE 10"zeh'STL PLATE n FRONT ELEVATION EMBEDMENT 25'MIHOR N ITS W!(4)}4•THRU BOLTS PLATE DETAIL Q PLATE DETAIL .x�_' ° 1)y'SLOT7ED U4'SLOTTED 1' O HOLES rf p C�i HOLES �0 4, -I' ° ° ante I 7118 31188 8'zB'kY'BTL PLATE OLj O FOR ELECTRICLL W/(4)15"O ANCHOR BOLTS 9•x8'x r•STL.PLATE 9.ni'STL.PLATE W!4)3'i ANCHOR BOLTS W/(4)1-ANCHOR BOLTS EMBEDMENT tY MIN. �BEDMPLATE DETAIL ENT 75'MIN. EMBEDMENT 25'MIN, VV/(6�THRU BOLTS PLATE DETAL PLATE DETAIL m ) PLATE DETAL � NOTE: NOTE: NOTE: NOTE: DETAILS SHOWN FOR REFERENCE ONLY. DETAILS SHOWN FOR REFERENCE ONLY. DETAILS SHOWN FOR REFERENCE ONLY. DETAILS SHOWN FOR REFERENCE ONLY. COORDINATE WITH SIGNAGE VENDOR. COORDINATE WITH SIGNAGE VENDOR. COORDINATE WITH SIGNAGE VENDOR. COORDINATE WITH SIGNAGE VENDOR. a DIRECTIONAL SIGN ai CLEEAR BAR DETECTOR al DREVE.STHRU ORDER W/ CANOPY a PREVIEW MENU nor Signage not approved. Separate permit required for all signage. Planning and zonir � o w � W w rn w of M H Y w co w o W m¢ O " U 2 LJJ z LO Z J RL N J W Z N r o N W G106. 1 APPLICABLE BUILDING CODES717 BUILDING CODE- 2015 IBC PLUMB11, ELECTRICAL CALNG C�ODE- 2014 NATIONAL ELECTRICAL CODE DE 20 5 PC ARC(Si�'�G� MECHANICAL CODE- 2015 IMC U4;'•CARLL•:F' NOTE: FIRE PROTECTION- 2015 PC _=+; LINGLE ENERGY CODE- 2015 INTERNATIONAL ENERGY CONSERVATION CODE - STATEMENT OF COMPLIANCE ACCESSIBILITY- 2009 ANSI A117.1 STANDARD -2319 PRIOR TO REQUESTING FINAL APPROVAL OF INSTALLATION, THE INSTALLING OTHER- CONTRACTOR SHALL FURNISH A WRITTEN STATEMENT TO THE LOCAL FIRE DEPARTMENT THAT THE SUBJECT FIRE PROTECTION SYSTEM HAS BEEN INSTALLED BUILDING DATA ' IN ACCORDANCE WITH APPROVED PLANS AND HAS BEEN TESTED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS AND THE APPROPRIATE INSTALLATION CONSTRUCTION TYPE- XzR UNPROTECTED STANDARD. ANY DEVIATIONS FROM THE DESIGN STANDARDS SHALL BE NOTED AND PRINKLED- BUILDING IS SPRINKLED COPIES OF THE APPROVALS FOR SUCH DEVIATIONS SHALL BE ATTACHED TO THE WRITTEN STATEMENT. AN "AS BUILT" DRAWING, DEPICTING ALL DEVIATIONS, SHALL ALLOWABLE AREA BE PRESENTED TO THE CFD INSPECTOR AT THE TIME OF THE FINAL ACCEPTANCE m 4 PRIMARY OCCUPANCY- A-2(RESTAURANT) _ w - TESTING. THE STATEMENT OF COMPLIANCE FOR FIRE PROTECTION AND FIRE MA ALLOWED BLDG.AREA- 9,500 GROSS SQUARE FEET(ACTUAL:2,282 SO.ET.) m m K ALARM SYSTEMS INCLUDE THE FOLLOWING SYSTEMS -- FIRE SPRINKLER SYSTEM TRAVEL DISTANCE- 250 FEET ALLOWED,86'-8-FEET MAX ACTUAL INSTALLATION AND MODIFICATIONS, UNDERGROUND FIRE SERVICE LINES, FIRE h 0 z o m __- o m m ALARM SYSTEM INSTALLATION AND MODIFICATIONS, COMMERCIAL COOKING HOOD ri f, m FIRE SUPPRESSION SYSTEMS, AND OTHER PERMITTED OPERATIONS. OCCUPANT LOAD COUNT TABLE PER TABLE 1004.1.2 IBC: 7o — —— ® TOTAL CIRCULATION AREA NOTE: AREA:720SO.FT J N a I� "AS-BUILT" DRAWINGS REQUIRED AT FINAL INSPECTION. WHEN APPROVED 0 A-2 TOTAL STANDING AREA CHANGES ARE MADE TO THE INITIAL APPROVED PLANS, THE APPLICANT SHALL IIIIIIIIIIIIIIII■ AREA:53 SQ.Ff. PROVIDE "AS-BUILT"DRAWINGS PRIOR TO FINAL INSPECTION. a„a °°° ' 53 SO.F.®ts=tt OCCUPANTS ( ) ARE TOTAL MISC.AREA OVENS,COOLER,FREEZER,RR a ,i AREA:684 SQ.FT NOTE: r F o°o[000°° L————— A-2 TOTAL SERVING ROOM AREA SUBMIT PLANS TO AND OBTAIN PERMIT FROM THE FIRE DEPARTMENT FOR THE X '_ - ° ® AREA:108 SO.FT 08 SQ.F.®tzoo=1 OCCUPANTS INSTALLATION OR MODIFICATION OF FIRE SPRINKLER SYSTEM. t I e ° � A-2 TOTAL DINING 00000 ' ARFA:116 1 1 NOTE: O / 116 SQ.Fr..0 t1s=a OCCUPANTS SUBMIT PLANS TO AND OBTAIN PERMIT FROM THE FIRE DEPARTMENT FOR THE _ L-1 oo°° °,°°gogogogog TOTAL FIXED SEATING L.F.=110'-0" INSTALLATION OF THE UL FIRE EXTINGUISHING SYSTEM FOR THE HOOD AND VENT. 1°°°°°°°o -o"L.F.®t:z4"=55 OCCUPANTS 334 S.F. o°° o°°Od 1hh ® A-2 TOTAL KITCHEN AREA NOTE: I AREA:867 SQ,FT PORTABLE FIRE EXTINGUISHERS (TYPE K AT COOKLINE, TYPE 2A-10B:C IN DINING °M. as7 SQ. .®1:200=5 OCCUPANTS ❑ o o° ° SHALL BE SELECTED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE J A-2 TOTAL PATIO AREA=3ao SQ.Fr. INTERNATIONAL FIRE CODE SECTION 906. MOUNT AT 36"-48" FROM FLOOR OT°moo TOTAL NUMBER OF SEATS=18 OCCUPANTS LEVEL. G.C. TO COORDINATE WITH FIRE MARSHAL FOR FINAL LOCATIONS. 9� o°oroTAL TRAVEL ;00000 °O o000000a o0 0 o$DISTANCE:43'-5" ' INTERIOR TOTAL 80 OCCUPANTS INTERIOR AREA: 2,882 SQ.Ff. EXTERIOR TOTAL:18 OCCUPANTS PATIO 380 SQ.FT, Q O'o° o°°°oo° 000000°000° o 0 o I TOTAL 98 OCCUPANTS TOTAL AREA 3,262 SQ.Ff. TWIN FALLS FIRE DEPARTMENT NOTES: - A VISUAL ALARM DEVICE (EXTERIOR HORN/STROBE) SHALL BE PROVIDED IN BID TEH AREA OF THE FDC. OCCUPANCY LOAD m o TOTAL TRAVEL y `sy'"ti a�" EXIT-ASSEMBLYENT CALCUUTED PER TABLE 1019 1 IBC - MANUAL FIRE ALARM BOXES SHALL BE A MINIMUM OF 42 INCHES AND A o�ol A-2 ASSEMBLY- s NET so.ET./OCCUPANT(STANDING Roots) DISTANCE:69'-0° s,`. "P A-2-/SSEMBLY- 15 NET SD.Fi./OCCUPANT(UNCONCENTRAIED TABLES AND CHARS) MAXIMUM OF 48 INCHES MEASURED VERTICALLY, FROM THE FLOOR ogo� o A-2 ASSEMBLY- 1 OCCUPANT PER 24'(nXED SEATING) LEVEL TO THE HANDLE OR LEVER OF THE BOX. ogooa ° A-2-KITCHEN- 200 GROSS SO.FTJOCCUPANT - MANUAL FIRE ALARM BOXES SHALL BE RED IN COLOR. L o ALLOWABLE EGRESS WIDTH - THERE SHALL BE POSTED, NEAR OR AT THE MAIN ALARM PANEL OR _-_ % °� EGREss wlorns CALCULATED PER 1oos.1 IBC ANNUNCIATOR SHOWING THE SYSTEM APPLIANCE LOCATIONS PULL BOX, ezwec S wml SPRINKLER SYSTEM-0.2°PER OCCUPANT. ( ~' ' ' ao OCCUPANTS AT 0.2"=I6°OF EGRESS WIDTH DETECTORS ETC.) ALARM CODES AND OR OPERATING INSTRUCTIONS. THEY P oa°OF EGRESS WIDTH((3)36-DOORS)PROVIDED °°o°o°o°o°o°o°o°o°o°o°o°o°° °°°°°°°°°°°°°°°°°°°°°°°°°°° ° N °°°°°°°°°°°°°°°°°°°°°°°°°°°° °°°°°°°°°°°°°°°°°°°°°°°°°°°°° �SHALL BE LAMINATED OR PLACED IN A BINDER FOR LONG TERM USE AND °° ° °° °°°° 'i � � °O _ '.' EGRESS WIDTHS TO BE A MINIMUM OF UPDATED AS NEEDED. ;�` 6,24 PLUMBING CALCULATIONS - THE KNOX BOX SHALL BE INSTALLED TO THE RIGHT OF THE MAIN ACCESS ° -- DOOR(S). IT SHOULD BE MOUNTED NO HIGHER THAN TEN FEET FROM ° Ego OCCUPANTS=(TOTAL AREA INCLUDING PATIO-(CIRCULATION AREA+MISC.AREA)) GROUND LEVEL. ALTERNATIVE LOCATIONS WILL HAVE TO BE APPROVED BY OCCUPANTS=(3262 SQ.Fr.-(720 SO.F.+684 SO.FF))/30 THE FIRE MARSHAL. DISTANCE:70'-5° 000 o - OCCUPANTS=(3262 SQ.FT.-(1404 SO.FT))/30 000Eoo i j., OCCUPANTS= 1858 SQ.FT./30 - PORTABLE FIRE EXTINGUISHERS HAVING A 1.5 GALLON K RATING SHALL BE ¢ OCCUPANTS=62 PROVIDED WITHIN 30 FEET OF THE COOKING EQUIPMENT. ADDITIONAL TYPE $`� -->PROVIDE FACILITIES FOR 31 PERSONS OF EACH GENDER<-- J _'^K, o ° _ `°"' from Table 403.1 Minimum Plambmg Fnililm(tPC 2015 pg4-4) K EXTINGUISHERS MAY BE REQUIRED WHEN THERE ARE MORE THAN 4 ogo[000�00000gogogo�o� °goon° FRYERS HAVING A CAPACITY OF 80 POUNDS. 4 a ao°M°�° �°� goo °° ° � '; �,NUM °o°� °°°o''° '°°°°°° °°° °°°°°° '°°" --� o°�°pa°or wale<CUR— [lrinale ea�amdea f°�aLain: ov.e� 000 o ne°°°°°°0008°° W cli - A MANUAL ACTUATION DEVICE SHALL BE LOCATED AT OR NEAR A MEANS OF ggTOTA1 TRA"VET" rpXp °° -zns�anlr na= mae as male ale Soo o m"ealaM °06 °�'a�oo�0000°° 000�o�°°OOO000° Pa"cy- 1:]5 1:]5 1:200 1:200 tawdry W CIO EGRESS FROM THE COOKING AREA NOT LESS THAN 10 FEET AND NOT ogglsrANCE a3 a °T°TOT m m.,n 9a� °°°° n �s fflsl MORE THAN 20 FEET FROM THE KITCHEN EXHAUST SYSTEM. THE MANUAL ° I ACTUATION DEVICE SHALL BE INSTALLED NOT MORE THAN 48 INCHES NOR . : ogog °LESS THAN 42 INCHES ABOVE THE FLOOR AND SHALL CLEARLY IDENTIFYt €1 K' W THE HAZARD PROTECTED. THE MANUAL ACTUATION SHALL REQUIRE A L o' MAXIMUM FORCE OF 40 POUNDS AND A MAXIMUM MOVEMENT OF 14 POST DINING m¢ o INCHES TO ACTUATE THE FIRE SUPPRESSION SYSTEM L------------------L ROOM MAX =z _j Q - - OCCUPANT LOAD ' j OF 80 AT MAIN ~" m Sprinkler System(s) ENTRANCE Sprinkler system plans shall be sent the State Fire Marshal Office and designed in accordance with current NFPA 13. Idaho State Fire Marshal 700 West State Street,3rd Floor t• Boise,Idaho 83720 I � .Signage Install an approved sign on the fire riser room door - Z FIRE SPRINKLER RISER INSIDE w © o cn N W L1_ 0 J aI LIFE 3�SAFETY PLAN N � G 110 213 mile[facmtes and Iaemm9?dates 603.4 Coal nooks shelves and -[almeet coat nooks shag be located e,closet. 213.1 General.Where toilet tcillties it bathing tcillties are prwi-they shall wtnln one of the reach ranges specified in Section 308.SheNas shall be located 40 604.52 Hear wall.The rear wall gate bar shall be G6lnenes ono com)long Exception: comply wNi Seaton 213.Where n.let mciNies antl bathing lacilnies ere P.ided In IncM1es(I F16 mm)minimum antl 481nthe(1219 mml maximum above the Ill minimum and extend from the P-die,of the water close112 i'Ple.(305„1 When loveted At the side of A toilet)h,ped,ent the toilet co,ped,ent �---------� lacilihes permmeit by Section 2aG 2.3 Exception)not to connect stones by en floor.Medicine cabinets shall be located wilhausable shelf no higher than 44 minimum¢ resitle antl 2a IncM1es(fi10 mm)mnimumonme mM1er sitle. tloor opening sM1ell provide,clear witlm of 3a incM1es(86a mml minimum. ;18min atinterior cessible route.toiler facilities and bathing facilities shall be prrnatled onastory I,,he,F118„),awmum above the fil floor. Exceptions ^^IFnII^^ onnected by en accessible route to en acoesefll entrance. 1.The rear even bar shall be permitted to be 2a inches(610 com)long minimum, 604.8.1 3 Approach.CInterlmenis shall be,ranged for len-hand or right-hantl c>° V 4s] \`xAATp111111/////f�A„' cG 603.5 Accessories.Where towel or sanitary nap kin de,e the waste re[eptacles, leretl on the water closet,where wallspacetloes,rot permilalength of 3fi approach to the water closet O VV 124 min at exterior E„ ARp 2132 Toilet rooms and bathing rooms.Where toilet rooms are Provi-eacn toile) other accessories are providetl In ro Ptifi.illties,et least one of each type shall nches(914ma)minimum due to the locafiGn ofarecessedfl n-Poent(1118 - Ht ��2:• "•y�r% m shall comply with Section 603. be locatetl on an accessible route.All operable pads.Including Coln skis,shall be mm)max um above the floor.Flush controls shall tie locatetl on the open side of 6W.B.t.4 Toe clearance.At least one side partition shall provide atm clearance of E X>8 CARL L 213.3%.meth fixNas antl ames.olies.Plumbin fixtures antl accessories 40 inches 1016 com maximum above the finish flow. the vestal closet exce tin ambula[o aces.ible com dmeM.tom In wltn 9i,I.. 229mm m uoo-ol mefini.of In.ntl bin, 1 .1 tlee .n 9 9 ( 1 P ry a Pa PY 9 ( ) inim ( 1 P E� NS J. _ uNGLE -_ rovided in a toile[room or bamin r m aired to com I w+m Section 2132 Sedion fiO4.82. minlmum be nit[M1e com rtmeM-sitle face of Ina a exclusive of Mon - m P 9 oc rep PY yo pa P ninon, earl II i I I _ oP shall comply with Sedion 213.3. 604 Water closets antl toilet compartments suppod members.Peiv. componele at the clearances shall be smooth without bi soa.lGeneral.Water closets and Idlet oompad,entssnau comply with Sectionsso4.]DI.pen.er..Toilet paper dispensers shallmmpy with snnon nos.and sham edges oraMaeNe s.rfaoes.companmems for GnImreds seshell proNtlea'13.3.1 Toilet compartments.Where toilet)hmpMmeMs are provided,at leas)one fi0a.2 tirougM1 60a.8. shall be J Inches a78 com)minl-mum antl 9In-,(229 com)maximumin tront of too clearance d 121nenve(305 com)minmum above the their floor ---- loilet)hmpadment shall comply with Section 6o4.8.1. the water closet measured to the centerline of the dspener.The outlet of the Exception:Toe clearance at ine side parttion is not requird inacompadment604.2 Location.The water closet sM1ell be positionetl wilM1 a wall or pennon Io me dispencer sM1ell be below thegritbar,19 inches(4G3com)minimumabove ine greater tha66Inotex(1676mmlwide. 3Q min ---- (a) 213.32 Water closd..Who,Acc,d to are provided,At least one shall comply antl to one sitle.The center-line,the ovater closet shell be l]'nille I32 finish floor and shall note locatetl behintl grab bars.Dispensers shall not be ofa J65 pull side b wim Section 11 8-S. mml mi um to 181ncM1es(45]com)max um from the sitle wall or Dertinon, type that controls detvery or that does not allow continuous paper flow. 604.81 S Grab bars.Grab I...hi comply with Section fine.A side-wall grab her () xcept tiro the water closet sM1ell be 1]'mclM1e,(432 com)minimum antl 19 inches -.plNno with Sedion 604.51 shall be provitletl and shall be locatetl on the wall push side 213.33U,inals.Whereon,or more urinals are provided at least one s 11obmply (9B3 mm)maxlmum fromtne sitle wall or parflllon In the ambulatory accessible 6048 Toilet companmenls.Wheelchar accessible toilet)hmpadments shall meet cloeesllotha waterctset.In atlmton,arear-wallgrebbarcomplyingwnM1section 48 min 9min (no latch) At Section 11 8-fins. toile[compartment spectied in Scotian 604.8.2.Water closets shall be ananged for the requirements of Sections 11 8604.81 and 60a.33.Compartments containing 60.4.5.2 shall be provided.Where separate gab bars are requiretl on atljacen[ 1pp qg5 a 11-it or right-hantl approach. ore than one plumbing fion a sM1ell comply with Section 603,A-Anlry walls at a common mounting height,eh L-shaped grab bar meetng the 213.3.4 Lavatories.Where lavatories are provided.at leas)five percent but no levee! accessible compartments shell comply with Sections fi.S 2 antl fiOa.H.3. dlrrrensionm requher -of Sections 604.5.1 antl Sol 52 shall be permitted. FFFIII than ones hall comply with Section 60fi and shall not be local h,toilet 604.3 Clearance.Clnances arountl wale,closets antl In toilet compartments oIn"In" -tell aomplyvnth Section ll B-604.3. 604 CA Wheelchairsoo-flo,compartments.Wheslchaireccessible Go4.82 Ambulatory accessible compartments.Ambulatory accessible 12 min v I1 213.3.5 Mrrors.where mirrors are provided,et lone[one shell comply At Seaton c-In,,ents eheu c.mpry wth section 6o4.e.l. sompe tetr a eh.0 comply with section sal 2. sot emit-m Eemnts General STANDARD SYMBOL PROPORTIONS sx 603.3. Soot Al Eve.Clearance arountl a water claret shot)he 60'nonne(1524 com) %1.1 Scope.The L.nore d D'son 9 tell apply where requretl by Divnim 2 or where II E R u-perpendicIll from the site wall and Go nche.a-com) se 1S' .Wh Ioheir access Ile)hmpeonn-shall be SO'nches(1524man 604.821 S'ze.Ambulatory a)h 01le companmenls shel have A depth of 60 referenced bvaregri rime t-the chapter. X>8 213.3.7Coet M1ooks antl sM1eNes.WM1ere met hooks or shelves are pmvitletl in toilet ,,measured perpend'cularfrom ine rearwall.Amdmum 60'nches(152a Alit "mum meas.redporFv,dh.lnr he.dowall end56'ncM1es(1-hut inches(1s24 mm)ln mum antlawid[h of 3s fiches(889 mm)mnmum and 3] ]tie F on s Aft u[toilet compartmeMs,at leas[Pro of each type shall comply with nel w.antl 48indlee(1219 com)deep rhoAx Pnoo shell be providetl in tlep minimum for wall hung water closets antl IS 11ohe.(1499 mm)tleep Inch rai com)maximum. Gas Dimrg..daces nit work surfaces L Sedion fio3.4,Where wet hooks or shelves are provided;n toilet compartments.at hoM of the water closec. mnimumforfleormeunled water closets measured perpendicular to?M1e rear wall. 902.1 Genial.Dining surfaces antl wont surfaces shall)hmply wit Sec[lons 502.2 antl 902.3. fro rT7 least one of aeon type complying with Sedion 604335net be provided in toilet Wheelchair accessble nmp.1re for diildnerl use sM1ell be 50 inches a 52e 604.a2213...,Toilet comp.rn tl.......oluitingdoorM1ertlwere,sM1ell comply Exception: ompadmenteegmretltommplywith Section2133.1.Where orethooksor 604.320AxlAL.Thorequiretl clearance arountlmewater closet shell be permittetl mm)witle mini-roammeasured pementlicular to the sitle wall,andas1 ,e Ftse with Sed1on116-404,exceptthatlflheapp,,,h lstothelatchsld,.fthe Dining surfaces antl work surfaces for chlldren's she)be permited to oxn,lywith shelve.areprovmetlm bmM1ingfac'Ilides,atleadone of each type complying with .ovarl,P the water closet associated grab bare.dispensers,sanitary napkin com)deep minimum for wall hung and floor mounted water closets measured )hmpa ,tloor,clearance between the door sideof the)hmpadment and any Sedion 9024. CD �N Sedion E03.4 tell v... ine.requiretl to complywiIn Section 21 GAE dlsposm units,coat hooks,sheNes,accessible routes.clearfloor spacend perpentllc.lar to tlee rear wall. obeWdion let 1 be44inch.h118mm)ninimum.Thetloorsha11 be Sell ro� s required atother-es,antl the fuming spece.No other fiAsoe or A dove pullmmplying with Section 40a.2.]Unit be pl H on both sitll of the 9022 Clear floor or ground space.Aclaar floor space complying wth Section Sol podtoned EJ In 603 Toiletntlhetinn.,en. obArudions sM1e11 telocated vAthin the regmred velar Glosd clearance. 80a.el1.1 Maneuvering space with ln-swinging door.In awfiealchdr accessible door near the ldoh.TdldGompadment doors shall not eAhi the min;mum for a toward approach enrol be Provided.Knee antl toe clearance complying with Section 306 N � Us 603.1 Genial.1111.antl bathing rooms shill comply with Sedion Go, compasnont with an In-swinging tloor,a minimum 60 inches(t524 com)witle by requiretl compartment area. shall be provided. C / 604.4 Seel,.The seat height of.water closet above the Ill floor sM1ell be 17 3fi inches ha com)deep maneuvering space shall be provided in sort of the V (C) Z 8032CIearnces.Clearances sM1sllcomplywim Section 803.2 hes(432mm)rximumend 19inches(a83mm)maAnArn easuredtothetop clearance requretl In Sedion col el.1.See Figure.604.81.1.2 uh it 604.323 Gab bars.Grab bars.hall.-ply with Sedion S.A sidewall grab bar 9D2.3 Height The lopsdtllning surfaces arm work surfaces shall be 28 inches(]11 com) push side,door provided with � of the seat Seats shall not be sprang to return he A liked position.Seals shall bet fiO4.8.1.1.G th complying with Sedion Call.5A shall be provided or both sides of the inim.,antl 341nches(864 mm)maximum above the finish floor o,ground. both closer and latch W3.2.1 Turning space.Turning sac pe complying with Sedion G04 shall be none,(el com)high maximum. com m portent. provided wtbin the r..m. Go4.RA1.2 Mne.vedng.pace wuh. gPning ide tloor.lit.wheelonex aomesmle m ALTERNATE DISPLAY CONDITIONS AS PRE-APPROVED BY LOCAL AUTHORITIES Figure 404.2.4.5 Maneuvering Clearances at Recessed Doors and Gales J a Exceptions: Gmp ornent with A side-opening door,ether l swinging or out-swinging,A 604.83 Coat hocks and sheNes.Coat hooks shell be)hated within one of the gas Benches 9u 9 603.22 Cverlap.Required clear floc spaced clearance Atfi ev and tum;ng 3.A31nen(J6 mm)high seat shall be Pdmtted only In albeaninn,where the -inches(1524 mm)wide antl fi0inches(152amm)tleep maneuvering eacM1 ranges epecifiAd in Sedion ses Shelves shall be locatetl 40'mchee(1016 9o3.1 Genera).Benches shall comply with Sedion 903. space shall be ptoo,ned to over lap. existing fi#urels less than l s inches(381 com)high. space shall be ponitledin I-ofthe weter[loset.See Figure 6G,1 81.1 2, inhe rium no 4e'mclive(1219 ni maximum above the 1-A... 903.2 Clear rloor or gronnd space.Clear floor or ground space complying with Sedion Gas 60323 Door swing.Doors shall not.win shall be providetl antl shall be p.ltl.ned.the antl l the bench rem antl paallel to the shon 6" 32 min g into the clear floor space or clearance 604.SGab bars.Grab bars fo,wale,closd.shallcomply wit Section fi09.Gab fiO4.H.1.1.3 Maneuvering space with antl-opening tloor.In awM1eelcM1air accessible fins Urinals axis or the bench. MIN. lbh required for any fixture.Other than the doormthe accessible water closet bars shall be provided on the side wall closest to?M1e water closet and on the rear ompahment with an antl-omi door(facing the water Ilosd),either fit-swinging IiW.t Generel.Urinals sM1ellcwnplywtM1 Section fi0.5. iLedrnent a door,,any position,may on....h into the fuming space by 12 Well.Where ceperele grab bars ere requiretl on atllecel walls at a common out-swinging,a um 60 incM1es(1524 com)wide and 46 incM1es(1219 com) 903.3 S'50 Benches snail have seats thel are 48110 (1 deep com)long minimum antl 20 inches(Gas mm),axi,um. mo.Ming ndght en L-shaped,11hep rnebod the dimensional requiemens of deep i 8.11 e.rermg span mall be lxwmed'In hot onhe water closet see Figure 6062 Heigh aria aepm.urinate mall be me dell-type arm¢wall-n.ne tvpe won inches lsoe„Ideep,mimum and z4 inches)atom,)deep,axi,u,. White Figure o CLEAR OPENINGS MUST BE BETWEEN THE ExmMmn.. secupns so4al and soas2 shall be Permined. so4.e.1.t3. me rim nmches(432 mm)maxl-mum above mefinlsh noon or ground annals DOOR IN ITS 90'OPEN POSITION AND THE 1.Reserved. shall be 131/2lnches(34311)deep minimum measured horn the outer face of ea3.4 Back suppod.The bench shall provitle for back suppod or shell be Ill to a wall along FACE OF THE STOP 2.Where the.,,.room or bnmina-room is for individual use and A clear 11B-ro4.5.1 Side wall.The sitle wall grab bar11 be 42mGhes 1-com) 604.8.1.2 Doors.Toilet compartment tloors,mclumng tloor h.,d-.,s 111.1 the urinal in,to the back of the n- IN long dlmension.Sack support sM1e11 be 48'mch F219 hnne rg mini mum and shall extend Blue Background floor space oo Iingwihh S.1.r3.5.G proviU.-Ithint.,00m long minimum,lowted tto the water[lose? Ath Sedion'04 exceptthel if the approach is from the push sitle d the from.poll 2'I.ch.e(Go n,ni nnum above the sent suo.ohn a point 181nd1e.I-com) - beyondtheat[oftetlm,swing,tloor.shell be permitted to swingmto the 2.Where an atlministrlive.,torty requires)lush controls for flush Abree to ompartment door,clearance between the door side of the compartment and any 605.3 CI ear rlmrspet,Adea,floor of ground spade complying wl[h Sedion 305 - ,above the seal.udace.Back suppod shall be 2'/2lnehe.(64mm)maxlmum horn clear floor space or clearance requhed for arty fixture be locatetl ine position tel conllids wish telo[.tlon or she rear gab bar, obstruction shell be 48 inches(1219 com)milmum,ensured perpendicular to she positioned for foh,nd approach shall be Provided. ?M1e rear edge of the seat measured h,vi lly. then the rear grab bar shell be permitted to be split or shol to the open ompadmont door In its closed position.Doors shall be located In the front Parttinn Single Door 603.3111—Mlrtoa located above lavatories or)huntedops shall be'mdelled sitle of the toilet area. inhe side wall or partition farthest horn thewater closet Where located in the 605.4 Flush controls Put controls shall be hand opened or automatic.Hand cal.5H,19M.The lop of the bench seat surface shell be 17,,,hes(432 mm)minimum and 19 with,¢bottom¢tlee of?M1e reflecting surface 00 incM1es(1016 mm)maximum front petition,the tloor opening shall be4inches(102 mm)meximum horn?M1e operated flush)hntrolsshellco,ply with Section 309 except that the Ilus II-I inche51483 com)maximum ove ab the finish floor or ground. 32 coin above the 1-floor or grountl.Minors hoticomed above lavatories or 604.E Flush con Vol,.Flushc-11,shall be hand operated or automatic.Hand sitle-111,p htion tensest horn the ward chsd.Where located In the side wall or let be mountedat,maximum height of 44 inoh.o F 118mm)above the finish oeuntertops shell be lnsteled with the book,edge of the reflecting surface 35 oin.rubed flush Porrolsshallcomplywith Sec tion303excepltheyshallbe)mated pa1Non,the door opening sh,111 be4 inches(102 com)maximum horn the front flm,. 903.6 Shmturel length.Benches shall beAtl-In to wallol tloor.Nlowable stresses shell FIGURE 703.6.3.1 815 inch Ree m,)mAAnnx.above the finish floor or ground. 44 inner i'Ite.(305com)max mum in.the rear wall antl exknding 54 inches parttion.The door shall be s.lr-clomng.A door pull complying vets Sedion W4.2.] rot be exceeded for materials used when A vertical or horizontal force of 25D Pound,F112 N) 0-com)m um from to rear wau wim to front end Positioned 24,1(610 .he I be Placetl on hot rode.of the on,,near the Iatoh.Doom eh.0 not.Ani INTERNATIONAL SYMBOL OF ACCESSIBILITY com)m nimum in front of me weer closet. the clear floor space or clearance required for any fixture.Doers may swing Into is Applied et any point on me seat,fastener,mounting device,or supporting esudure. In portion of mane.rer ho apace which do.hioverlap In.cl..rnce req.hed °p CLEAR OPENINGS FOR TWO LEAF DOORS Goo wet,d l.nh. oov,Ir Dho wet wet 1)hafions,me surface of Beat shau be sup reeidal eod.nalmm eoo.mmate water. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL COMPLY WITH MUST BE BETWEEN EITHER DOOR IN ITS 90° OPEN POSITION AND THE EDGE OF THE GLAI Gek-om aislesAnd.,tA es and se.A.And tars. A BLUE 7ACKG.1 THE SYMBOL SHALL CONSIST OF A WHITE FIGURE ON OTHER DOOR goad General check-dot deter arm sores and¢amide m.mers shdlmmplywim me A BLUE BACKGROUND. THE BLUE SHALL BE COLOR NUMBER 15090 IN 59'MIN.AT FLOOR MOUNTED aupioen.requirements of section 904. Double Door "MIN. "MIN. W.C.WHEN DOOR SWINGS IN 9042A FEDERAL STANDARD 5956 adie,ertto AAsib,nrface compliers Win trediocomprywtm section 9oa shau be located gsu yrg wim secuon 4oG. ACCESSIBLE ENTRY SIGNS SHALL COMPLY WITH CC A117-IBC CH.11 Figure 404.2.3.2 Clear Width of Doorways csry oFLlxeRuGH cery OF urve E RUSH 56•MIN.AT WALL MOUNTED g�URE EI'J's 17"-18"rU� ACT AT's W.C.WHEN DOOR SWINGS IN sa.3Ch..I-telvIl Checkbm aisles shau comply wtn Sedion Per 3. SIDE E 4e0.a60 HIDE E 54"MIN, 904.31 Aisle.Aisles tel comply with Section 403, 60"MIN. 9032 Cmher The[PLMer.urf,G1 he Six all b638m[haa(965 com)maxim.,,EP the ACCESSIBLE SYMBOL REQIREMENTS DOOR CLEARANCES und.finish floor or gro The top of the Do,Mer Add.prdedion eheu be 2-hi(51 com) -- m rnum nhove to top of counter surface on to a isle,ire of the olieck-out counter. _ 24"MIN. GG4 4 Sales and service)hunters.sales couriers and salvia¢counters shall complyw;t r via sin 42"MIN Se inn DA 4.1o,90a.4.2 Th.am.esible podioronh.conedop-11 ederdth.sam. Lei 60 r' �e GRAB BA depth as to sale.or.emm on-,top. e eIt o °f5,"�i • o - Sol.4.1P-1.1 app..h AIwdion onhe...le...le.tens Who- mm)lore z OAP �I i FLUSH ACTIVATOR mum and 34 tones(e64 com)nigh maxim.,above me.riles odor shell be Provided!A 12' 98' MML 1r ON WIDE SIDE dear floor or ground spade[omplying wim Sea-Gas stall be posdoned for a Parellel MIN. 34"MIN. epproecn adlaottloto38inch(914com).nniu,hI.rThofcoveter. �' MIN. MIN. GRAB BAR r CLEAR sss Exmpton:whore me Provmnd nuln,sud.oe A less man 36 maser(914 com)long,menthe 4B•MIN. ounce,surface shell be h4Apou(Bfifcom)Mgh maximumabove thefinish floor. ] 8IH.42 Forward approach.A portion of the)hunter surface mat Is theI has ffal oo4 com)long Oat 32"MIN. art h328MIN.. 18..fil m.m nit a4'mcnes(864 com)nigh m heum.M1bl lee RnI.-.one, it toe.pace olmplying with Sedion See shall he provked unite,the counter.A clear floor or grountl space CLEAR CLEAR �� '4so eo,plyrng wim Sedion Gas shall be positioned for a N warn approach to the cooler. LL - �LJ \N 1I sans Fmd Anvionfine..Cooler.in rmd.emm Imo.shau comply wnM1 sedinn sa4 5.1 Son-service shelve.nit it'Ispnstg devices.Solh.e solve. it di.pneina 39-41 U,v t,teelewe,tl'I.hw.re,endimels b,d it¢¢vane het mmplyAt section �a I 36 in - ---fIno � 3oe. 280in 12 min �0�min - I 904.5.2 Tre,elh-.The tops of tray no,,shell be 281nche.(]11 moo)trim antl 34 - m id WS I to nches(864 m,)maxmum above me finish floor or ground. 12 max 1 1 ' 305 42 her E n ECIO�A �CLEA�R S_ ��� 44"MIN.CLEAR fi01NCHE5 DIAMETER SPACE T-SHAPED SPACE FOR 190'TURNS DOOR MSERIES E m <S s tmnS(Br m m 7-9 D1GPExs sLannon 48'MIN. fB0.199 48'MIN. Figure 604.5.2 REAR WALL Figure 604.5.1 SIDE WALL GRAB AT WATER CLOSET GRAB AT WATER CLOSET sin J TOILET FACILITY, RESTROOM FIXTURES AND ACCESSORIES REQUIRMENTS BUILT-IN REQUIRMENTS ''' cli � _ w m= RtWDE Ra m, __ r ------------- w AND A W M E E 1aJ .E if A 90THDOORSOPENOUT DOORS AT ADJACENT WALLS DOORS AT OPPOSREWALLS ,y�Y LU Q /wi / 606 Lavatories end sinks '••Q Q - 606.1 General.Lavatories and sinks shall comply vets Section Sol I. CI ear lloorspad Ivion,dhin roor space com.,hpl ne ff,Sn 05,postli.11b for 2 Z J Q)"'wart epproecM1,antl knee nit Lae cleernce complying wtM1 Section 306 shall be providetl. Exceptions 10 max w J .A parallel approach complying wim Section 305 shall be permitted to a kitchen sink in l!O Z ..p.oewaareamok top or mnvelinelrnge'I.not prwiaea antl rower her.. Figure 308.2.1 Unobstructed Forward Reach Figure 308.3.1 Unobstructed Side Reach Z z.Reserved. U 1T m CLOSER r a.Not ueed 20.. >20-25 max / 4.AMm ole.ance of 24'mche.(610 nnh In muhrob-o tenl.n noon oreronit she doers shall be permitted at lavatories and sinks used primarily by children 8 through 12 years where bd din or m.mer e.rface is 31 manes paJ com)maxlm.m above ma rites floor X SrA parallel approach complying At Seaton 305 shall be permitted to level......d Ark usetl primarily by cM1;ltlren 5years antl younger. E e E KNEE CLEARANCE TOE CLEARANCE• a The tliP of to ovesow shall not be consitleretl in tletermining knee antl toe x ,< E B'MIN. B•MAX. •Nate:If a minimum 7.Nc more than one bowl of a multi-bowl sink shall be requiretl to FoAde knee antl toe v R PULLSIDE 9 inches hagst of ice clearnce complying wtM1 Section 306. PULLgpE Pula g� - 1r MIN_ clearance ei provided, so6a Height.Lavatoree artl sinks anon be'ms[nued wim me Sol of m.Nether of me rim o, 10 max >10.24 max _ er sudece 34inGM1es(864mm)max;mum above the the),floor or Ground. Ia'MN. ak.x at SIDE ELEVATION a maximum ofe5 inches Goes zss zsselo CLEAR AT DOORS of the 48 inch of lea (a) (b) (a) (b) y - G0 Faucets.Controls for faucets shell comply with Seaton 309.Hand-operated metenng 18 MN. CLEAR AT 4 0oar Space required atr mumts.net remeln opn t,10.,who.minimum. Figure 308.2.2 Obstructed Forward Reach Figure 308.3.2 Obstructed High Side Reach � ; DUARAe poops ' -- `/� 1T MIN. the fixture may extend I$ $ - N M lnt0 ale too spaCR. Gas.Ehmosedpb.o.,deurfaces.Wetersupplyantl tlminp;pnsunderlavatoriesend sinks G09 ReecM1 rage. 30H.3.t Unobehi-Whereaclearrloororgr...J space din. rental epp..h to an 3G N. �I orelb aslve soda s fi tl to red a eind contd.There shall be no sharp 309.1 Genealcal switches Consols and switches in on 309. maximum and the low side reach sh,111 be 15 inches(381 com)m ( ) r 0 oterwise con gore pro g .Heath ran M1 Il com t Smt element and the sitle reach;.unob.Wded,the hl h sitle leach snail be 48;nches 1211 com "Eam .................... a r ce under lavatories antl sinks. (nimum above the finish floor ? w Goad i Dec, landed ro be used by me hovout,ent1he v of a or ground. F fi06 fi Atllacent sitle wall or partltim.Lavatories,when located adlaceM t...ide wall or m or area to control lighting antl receptacle ntlds,appliances o cooling,M1nting antl Excep[lons: 2 CLEAR b panllln shall be A mini-mum of 18 inches(457 com)to the centerline of the flxmre. rveMllatlna equipment shall comply with Sedion GOB except the low reach shall be reasured to 1.An ohethun.n shall be permitted between the clear floor or ground space end to Uj FLOOR O the bottom of the outlet box and the high reach shall be measured to the top of the outlet box. element where to tlepth.the obdr,vhn Ion-(254 com)maximum. ) peoul THIS SPACE 606.7 Sink tlepm.Sinks shall be fi'h inches(165 com)ticep maximum. 2.Chio pads of fuel dspensea s 111 be Pe 111ed to be G4lin-(13]2 com) AOOITIONAL SPACE m 308.1.2Elmhi,a ovptaGleoutlels.El hoalreceptacle oulletsonbranen Gllcults of 30 mum measured soon the surface onM1e vehicularway wherefuel tlispensers are _ IF DOOR IS EQUIPPED LL3w amperes or less and communication sy y p maw stem rece lades shell com with Sedion 308 exce 1 Insmlled on existin curbs. WITH BOTH SE LATCH _- r r z Ihe low reach shall be measured ro me bottom of Phe outlet box antl me bIUM1 reach shall bit g I r AID ACLOSER 1€ ail r i r i r """"•""•"""""""""4 measured hotlylpoftieomletin- Gas 32 Obshucled high re,,h Who...ar floor or ground space All a Parellel approach I I yg ?ems J 7B'MAX ton elementridthe M1igh sitle reach is over an obdrudion,Iha height of the obsVudion sM1ell T ,1( PUSH SIDE ]..��rEmp > Ph G09.2 Forwartl reach. be 34 inches(864 corn)maximum nit the depth d the ob.VUChi shall be 24In-(610 com) PU9H gDE i I PUSH SDE i$ < .y IW m 2.1 u.-Ited.Where a I.-reach;.unobsWded,the high.-d reach shah be maxmum_The high side Aeol,sM1ell be 48 in-(1219 one maximum for A reach depth of 10 -1k.41. H•MN Tag MINI 08 48"EAM. as inches a219„)maximum end me rove forward reach shau be 1s inches(Go com) manes(254 com)memmum.where to renM1 aepm=LA 10 inones(254 com),to high tr Inimum¢bore the finish floor or ground. reach shall be 46In-(1168 com)maximum ill a reach depth of 241n-(610 com) N W PLAN Ht---Al/ MUM IF sea, V J Sea 22 O-Ited high reach When,,M1igh for-was reach;,over art obdrudion the clear Exceptions: HAS ACLOSER Uj floor space th ll extend beneath Ile.1...rh for a dstance riot less tan the Regmretl reach 1.The top of Axth,mwhirmend doll dryers shall be permitted to Ni 36 inches (e)FROMAPPROACH (b)HINDE APPROACH E)LATCH APPROACH !1 depth over to onArLohon.The high forwartl reach sh.11 be 48 mono.(1219 com)mnxi-mum (914 com)maximum above n finish illm p N V where the reach tlepth is 20 inches(508 com)maxi-mum.Me,the reach depth exceeds 20 2.Operable parts or rue)tllspensers shell bit permitetl t be Sa incM1es(13]2 com) w U incM1es(508 com),me M1igh-ed!reach s 111 he 44 inches(111.com)maximum antl In. mum measuretl horn the surface of the vehlcula,way where fuel tll.poncers are \ react,depth s 111 be 25 incM1es AGE com)maximum. inst211ed on existing curbs. = L Q Gre GSide reach. ANSI A117.1/IBC LAVATORY REQUIRMENTS REACH RANGES MANEUVERING CLEARANCES AT DOORS G 120 C=GENERAL CONTRACTOR L=LANDLORD O=OWNER R=PRODUCT DATA/REPORTS D=SHOP DRAWINGS S=SAMPLES V=VENDOR C=GENERAL CONTRACTOR L=LANDLORD O=OWNER R=PRODUCT DATA/REPORTS D=SHOP DRAWINGS S=SAMPLES V=VENDORS FURNISH INSTALL SUBMITTALS REMARKS FURNISH INSTALL SUBMITTALS REMARKS DIVISION 1-GENERAL REQUIRMENTS L O C V L O C V R D S V DIVISION 10-SPECIALTIES L O C V L O C V R D S V gECIARC&��4ii ��,... yr� BUILDING PLAN CHECK&PERMITS • • EXTERIOR BUILDING SIGNAGE • • • ROUGH POWER TO JUNCTION BOX BY GC CARLL :F`C' LINGLE TEMPORARY FACILITIES • • ACCESSIBILITY SIGNAGE • • o : AA 2319 TEMPORARY UTILITIES • • INTERIOR DECORATIVE SIGNAGE • • CONSTRUCTION TESTING&REPORTS • • • ARTWORK&MURALS • • MILLWORK VENDOR TO INSTALL I• SPECIAL INSPECTIONS • • • FIRE EXTINGUISHERS • • F.S.E.C.WILL PROVIDE(1)CLASS K&(1)ABC CONSTRUCTION DEBRIS REMOVAL • • SAFE • • PROGRESS&FINAL CLEANING • • TOILET ROOM ACCESSORIES • • CERTIFICATE OF OCCUPANCY • • TOILET ROOM MIRRORS • • r in DUMPSTERS AND TRASH BINS • • LOCKERS • • m SOUND SYSTEM&SPEAKERS • • m m a DIVISION 2-SITE WORK o m WINDOW SHADES • • '0 w� EJ N DEMOLITION- IF REQUIRED • • m r- PATIO LIGHTING • • DIVISION 11-EQUIPMENT PATIO HEATERS • • UNDERGROUND UTILITIES BY LINES BY L.L. FOOD SERVICE EQUIPMENT • • a D/T DETECTOR LOOP PAVING • • LOOP PROVIDED BY HABIT,LL INSTALLED POS EQUIPMENT • • POS CABLING • [I, DIVISION 3-CONCRETE OFFICE EQUIPMENTCONCRETE SLAB • • G.C.TO PATCH&REPAIR SLAB AS REQUIRED EXHAUST HOODSCONCRETE PADS&WALKS • • DRIVE THRU SIGNAGE • • PIERS BY G.C. MODIFICATION OF CONCRETE PAD AS NEEDED • • FOR INSTALLATION OF PATIO HEATERS DIVISION 12-FURNISHINGS DRIVE THRU SIGNAGE FOOTING PIERS • • SIGNAGE BY VENDOR BOOTHS AND BENCHES • • TABLES,(TOPS AND BASES) • • DIVISION 4-MASONRY CHAIRS AND STOOLS—m H • • HIGH CHAIRS • • PATIO FURNITURE • • DIVISION 5-METALS OFFICE CHAIR • • METAL STUDS • • OFFICE CABINETS • • WALL BACKING • • INTERIOR PLANTS • • NMI STAINLESS STEEL CORNER GUARDS • • STAINLESS STEEL QUILTED WALL PANELS • • DIVISION 12-PLUMBING PATIO RAILING • To FIRE SPRINKLER SYSTEM • • GC TO MODIFY EXISTING PER HABIT LAYOUT DIVISION 6-WOODS AND PLASTICS PLUMBING SYSTEMS • • • ROUGH CARPENTRY • • PLUMBING FIXTURES AND FITTINGS • • TRUSSES&OPEN WEB JOISTS • • WATER HEATERS • • IRS FINISH CARPENTRY • • MILLWORK VENDOR TO INSTALL WATER FILTERS • • CUSTOM MILLWORK • • • WATER METER • • COUNTERTOPS • • • BACKFLOW PREVENTOR • • GAS EQUIPMENT REGULATORS • • DIVISION 7-THERMAL AND MOISTURE PROTECTION GREASE INTERCEPTOR • • INSULATION • • GAS SERVICE • • • WATERPROOF MEMBRANES • • GAS DISTRIBUTION • • JOINT SEALANTS • • GAS METER • • BY UNLITY COMPANY-GC TO COORDINATE SEALANTS AND CAULKING • • PATIO HEATERS • • UNDERGROUND GAS/ELEC LINES BY L.L. ROOFING PENETRATIONS,CURBS AND FLASHING • • DIVISION 23-MECHANICAL DIVISION 8-DOORS AND WINDOWS(REFER TO DOOR SCHEDULE LOCATED ON SHEET A200) KITCHEN EXHAUST HOODS,SUPPLY FAN,GREASE FILTERS • • J REAR SERVICE DOOR AND FRAME • • ANSUL SYSTEM W/PULL BOXES • • PULL STATION ROUGH-IN BY G.C.(IN WALL) o REAR SERVICE DOOR HARDWARE • • EXHAUST FANS • • ACCESS PANELS • • • EXHAUST AND MAKE-UP AIR DUCTWORK • • W LL.I CIO ENTRANCE DOOR • • DUCTWORK FIRE WRAP • • ENTRANCE DOOR HARDWARE • • • HVAC UNITS AND CURBS • • W w M H GLASS AND GLAZING • • AIR DISTRIBUTION DUCTWORK • • — INTERIOR DOORS,FRAMES AND HARDWARE • • • • REGISTERS DIFFUSERS AND GRILLS • • • ~Y W in Lu Lr- SPANDREL GLAZING PANELS WHERE INDICATED ON PLANS • • TESTING BALANCE REPORT • • • MUST BE THIRD PARTY m¢ O cd 0 DIVISION 9-FINISHES AIR CURTAIN • • 2 Z ¢ — Z J GYPSUM WALL BOARD • • DEMISING&PERIMETER GYP.BD.BY LANDLORD REMOTE REFRIGERATION FOR KITCHEN EQUIPMENT • • E.C.MAKES FINAL CONNECTIONS LIJ PORTLAND CEMENT PLASTER(STUCCO) • • ROOF PLATFORMS • • ~C.) a� m CERAMIC TILE • • MAU UNIT AND CURB • • THRESHOLDS • • DIVISION 26-ELECTRICAL SUSPENDED ACOUSTICAL CEILING SYSTEM • • ELECTRICAL METER • • BY UTILITY COMPANY-GC TO COORDINATE TECTUM ACOUSTICAL CEILING PANELS • • LIGHTING FIXTURES • • GC TO CONTRACT W/OWNER VENDOR - LIJ EPDXY FLOORING • • GC TO CONTACT W/OWNER VENDOR LAMPS • • GC TO CONTRACT W/OWNER VENDOR J SANITARY WALL PANELS(FRP) • • EMERGENCY EXIT LIGHTS • • GC TO CONTRACT W/OWNER VENDORui 0 PAINTING • • EMERGENCY EXIT SIGNS • • GC TO CONTRACT W/OWNER VENDOR - TILING • • FIRE ALARM SYSTEM • • • 1-CONDUIT FROM HABIT TO BASE SYSTEM BY LL („) STAINLESS STEEL WALL PANELS • • SECURITY ALARM SYSTEM • • CONDUIT FOR TELECOMMUNICATIONS • • a n CABLING FOR TELECOMMUNICATIONS • • J m PHONE OUTLETS • • U) ELECTRICAL SERVICE • • Z RESPONSIBILITY SCHEDULE ELECTRICAL DISTRIBUTION • • G.C.TO PULL WIRE INTO SPACE FROM SERVICE INTERIOR LIGHTING FINAL FOCUS • • ADJUST LIGHTING PER LIGHTING AIMING GUIDE ? o NOTE:THE TENANT G.C. IS RESPONSIBLE FOR ALL WORK SHOWN IN THIS SET OF PLANS THAT IS NOT w N rn Lu SPECIFICALLY INDICATED IN THE RESPONSIBILITY SCHEDULE AS BY OTHERS- UNLESS NOTED OTHERWISE. RESPONSIBILITY SCHEDULE G 130 GENERAL REQUIREMENTS AND CONDITIONS �O"3E�I ARChi4ii L•'V CAAL Reference is made throughout these general notes work and include in their project pricing and scheduling FIRE EXTINGUISHER NOTES 1. Every required doorway shall be sized for a door not _ CAR L = regarding responsibilities and standards of care to be 4. PERMITS all required work and time for proper assembly to less than 3'-0" wide by not less than 6-8"high, z31s fulfilled by those providing services in the development and achieve the design intent of the Construction Documents. 1. Portable fire extinguishers shall be provided in capable of opening 90 degrees and mounted so that ' construction of this project.The General Contractor shall be The general building permit fee and all plan check fees Details noted'typical'imply all like conditions treated accordance with the Uniform Fire Code Standard 10-1. the clear width of the exit way is still a minimum of 32". FIRE DEPARTMENT NOTES: responsible for adherence to those requirements by his shall be secured and paid for by the General Contractor similarly unless noted otherwise.The architectural details Portable fire extinguishers rated 2A-10BC shall be management team and staff,all Subcontractors and other and/or Owner.Subcontractor shall secure and pay for shown are intended to further illustrate the visual design located with a 75 feet travel distance.See floor plans 2. All accessible public doors shall have the following 1. When alteration requires modification of a professional consultants not retained by the Architect. their specific trade permits. concept and the minimum recommended weather for additional information and specific locations. strike-side clear space to walls fire-protection system,plans shall be submitted protection for this project.Building code requirements, or other obstructions: separately for review. 5. INSURANCE: structural considerations,trade association manuals, 2. Fire extinguishers shall be mounted on the wall such 1. PERMIT DOCUMENT SET: publications and product manufacturer's that the top of the extinguisher A.When a door swings away(into the direction of 2. All spaces are to comply with 2015 IFC for Contractor and Subcontractors shall provide adequate written instructions shall also be considered in order to does not exceed 42"above finish floor. travel)12"clear space is required where both a fire-sprinkler protection. _ w " The scope of this set of plans is to provide a"permit insurance per their subcontractor agreement,and such complete the construction of the project.All possible field closure and latch are provided. m m a document set"and general notes hereinafter referred to insurance shall be appropriate to fully cover repair and conditions which may be encountered are not 3. All fire extinguisher shall bear a tag showing the State 3. Each required commercial kitchen exhaust hood and z m m as"plans".This set of plans is sufficient to obtain a /or replacement of their scope of trade work. necessarily described herein.Field conditions Fire Marshall's seal.The tag B.When a door swings towards the user(against duct system, by International Fire Code 2015 shall f�_ N building permit;however,all materials and methods of encountered which require clarification or additional shall indicate the date,month,and year in which the the direction of travel)18"clear is required on have a Type 1 hood and shall be protected with an N " construction necessary to complete the project may not 6.NAMED PRODUCTS: information shall be brought to the attention of the fire extinguisher was serviced. interior doors and 24"is required on exterior approved automatic fire extinguishing system install in 3 3 be completely described or detailed.The plans delineate Architect in timely manner and submitted via a Request doors. accordance to this code.Sprinkler system shall be m and describe locations,dimensions,types of materials The Architect makes no guarantee or warranty for For Information(RFI)form which will be provided by the 4. "K"rated portable fire extinguishers shall be provided deferred approval item. J a and general methods of assembling,fastening and products identified by trade name or manufacturer.All Architect upon request.RFIs always receive expedited for the kitchen area including 3. Tactile exit signs are required at the following locations weather proofing.The proper implementation of the materials shall be installed per the highest industry review and response. the directly associated work areas or storage rooms. per 2015 IBC: 4. All deocorative materials shall meet the requirements plans requires Contractor and Subcontractors to be standards and practice to ensure a high quality finished the local and State Fire Marshall Codes. familiar with the applicable building codes and methods product. 13.SHOP DRAWINGS: A.Each grade level exit door shall be identified by of construction specific to this project type.Details and EXITING a tactile exit sign with the word"EXIT". 5. Pre-Final Inspection required to verify emergency sections on the drawings are shown at specific locations 7.SCOPE: All shop drawings and submittals shall be forwarded to lighting and fire extinguisher placement.Additional exit and are intended to show general requirements the Architect during the first week after project award,but 1. All exit doors serving an occupant load of 50 or more B.Each door that leads directly to a grade level signs may be required. throughout.It is not the intent of these Construction The General Contractor and Subcontractors shall furnish no later than fourteen(14)working days prior to shall open in the direction of travel.The door shall exterior exit by means of a stairway or a ramp Documents to illustrate every unique construction all labor,equipment,and material indicated on the plans fabrication for review of compliance with the design swing into a full open position when a maximum force shall be identified by a tactile exit sign with the assembly or detail.The General Contractor and and reasonably inferred or required by the applicable concept.The following items shall be submitted prior to of 5 lbs.is exerted for an interior door and a maximum following words as appropriate: Subcontractor shall review their specific trade of work codes or required to implement the design intent of the the commencement of related work: of 5 lbs.of force is required for an exterior door. a. "EXIT STAIR DOWN" and include in their project pricing and scheduling all drawings. 1) HVAC units and components b. "EXIT RAMP DOWN" required work and time for proper assembly to achieve 2) Plumbing fixtures and components 2. All egress doors shall be operable from the egress side c. "EXIT STAIR UP" the design intent of the Construction Documents.Proper S. SUBSTITUTION: 3) Electrical distribution equipment and components without the use of a key or special knowledge or effort d. "EXIT RAMP UP" and thorough field implementation of these construction 4) Doors and door hardware (2015 IBC)and shall comply with 2015 IBC documents anticipates the continued regular involvement Habit Burger Grill LLC has selected the products and 5) Millwork assemblies and package components C.Each exit access door from an interior room or of the Architect and all the appropriate consultants as assemblies best suited to their operations,substitutions 6) Toilet accessories,partitions,and components Main entry/exit door: area to a corridor or hallway that is required to part of the basic services for this project. Requests For will not be allowed in most cases.Any proposed 7) Fire alarm system components and local contacts Locks and latches shall be permitted to prevent have a visual exit sign shall be identified by a Information(RFIs)always receive expedited review and substitution shall be documented and forwarded to the 8) Patio railings(as required by drawings). operation of doors where any of the following exists: tactile sign with the words"EXIT ROUTE" response. The Architect shall provide input to the Architect during the bidding period to avoid any delay in General Contractor and the Client as appropriate to the the project schedule.The General Contractor and any 14.APPROVED DRAWINGS: A.In buildings with an Group A Occupancy having an D.Tactile(raised characters and Braille)exit signs progress of construction to address and resolve specific subcontractor shall not make any substitution or change occupant load of 300 or less,Group B,F,M,and S, shall be placed on the wall adjacent to the latch design,detail,specification,finish and construction without prior written authorization from the Architect of The General Contractor shall be responsible for and in places of religious worship,the main exterior side of the door at 60"above finish floor to the issues which typically arise throughout the bidding / record. coordinating the work between the different door or doors are permitted to be equipped with key I centerline of the sign.(2015 IBC) negotiation and construction process. Subcontractors to achieve the design intent,meet the locking devices from the egress side provided: Submit complete documentation(catalog,sample, construction requirements specified herein and to require 4. Interior and exterior thresholds shall be a maximum of 2. BUILDING MAINTENANCE: mock-up,etc.)to establish that the proposed substitution all Subcontractors to use the most current building a. The locking device is readily distinguishable 1/2"above the adjacent floor.Exposed edges shall be meets or exceeds originally specified item department approved plans. as locked. beveled on slope to maximum of 45 degrees with 1/4" The exposed materials used in the construction of this requirements/standards.Finish Materials,Light Fixtures, change in level at any one point. project will deteriorate as the completed project ages Door Hardware,Plumbing Hardware&Fixtures:will 15.RELATED DOCUMENTS: b. A readily visible sign is posted on the unless properly and routinely maintained.Contractor require a minimum three(3)week review time-plan egress side on or adjacent to the door stating 5. The bottom 10"of all doors shall have a smooth shall provide a comprehensive maintenance manual substitutions carefully,the project schedule will not be The General Contractor shall obtain a full listing(or "THIS DOOR TO REMAIN UNLOCKED WHEN uninterrupted surface to allow the which specifically targets areas/materials that require adjusted to accommodate substitutions. copies)of all related documents not identified from the THE BUILDING IS OCCUPIED".The sign shall door to be opened by a wheelchair footrest. periodic inspection,maintenance,repair and Owner,but necessary to properly execute the work. have 1"letters(25mm)high on a contrasting replacement of deteriorating building and surrounding 9. CHANGES: background. 6. Door hardware shall be lever or push pull type and components.Special attention shall be given to 16. EXISTING CONDITIONS mounted at 34"to 44"above finish floor.(2015 IBC) landscaping,landscape irrigation,site drainage,building Any addition,deletion or change in the scope of the work c. The use of the key-operated locking device water run-off control,major structural components,and described by the plans shall be by written change order The General Contractor is solely responsible to review is revocable by the building official for due 7. Doors with automatic closing device shall be operable waterproofing of exposed wood and metal.All only. the drawings and verify the project site existing cause. with the following maximum forces applied to the latch maintenance procedures shall meet or exceed minimum conditions. Variations from indicated dimensions,sizes, side:5 lbs.for the interior,5 lbs. for the exterior,and manufacture recommendations.At a minimum owner 10.INTENTION: utility locations or access must be brought to the B.Where egress doors are used in pairs,approved 15 lbs.for self closing fire doors. shall have all roof,drains,skylights,gutters,downspouts, Architect's attention immediately for resolution to avoid automatic flush bolts shall be permitted to be used, J storm drains,French drains,footing drains,bio-swales The general contractor shall insure that all labor, schedule delays. The General contractor is not provided that the door leaf having the automatic 8. Provide a 44"minimum clear aisle width to required o and all site and building drainage systems checked and materials,storage,equipment,and transportation costs authorized to make any adjustments to the drawings, flush bolts has no doorknob or surface-mounted exits and access to the public way. cleaned annually to maintain proper functional working shall be included in the work for complete execution of dimensions or project layout without prior written hardware. w conditions for appropriate weather tight protection from the project.The Architect shall not be responsible for the authorization 9. Locate all accessible manually operated switches and W the exterior.In addition all exterior windows,doors, means,methods and/or techniques of construction 3. All exits shall be illuminated by emergency lighting controls between 36"and 48"above finish floor, flashings,vents,weather stripping,and caulked seals on unless the means and methods are specified herein,nor fixtures on their own circuit and shall be capable of working platform,or surface.Locate all accessible W all exterior wall,roof,parapet,fascia and soffit does Architect have any responsibility for safety 17. CUTTING AND PATCHING: providing a minimum of 1 foot candle of light at the manually operated switches and controls between 36" rn w F M H penetrations shall be checked annually and maintained procedures on the project site.All details,structural floor level. and 48"above finish floor,working platform,or surface. w o IGG W in a weather tight condition.All exterior plaster,cladding, supports,seismic attachments and structural All Subcontractors shall do their own cutting,fitting, (2015 IBC) Se and wood siding shall be inspected annually for cracking connections shall be installed to provide a clean, patching,etc.to make the several parts come together 4. All exit signs shall be internally or externally illuminated m < O vi G7 or shrinkage and caulked/sealed/maintained to provide consistent and finished high quality look. and to be fitted to receive or be received by work of other (2015 IBC). All exit doors exit doors when serving an 10.The operable parts,controls,and coin drops in =z k a continuous weather tight condition of all surfaces.All trades. occupant load of more than 50 shall be identified by an restrooms fixtures shall be mounted 40"above finishexposed wood surfaces shall be checked,resealed and/ 11.REVIEW OF DRAWINGS: internally self-illuminated type"EXIT"sign with direct floor.or repainted every 3 years minimum.Failure of owner to 18. CLEAN UP: power supply and battery back-up in accordance withDD follow above routine maintenance requirements shall be The General Contractor and all Subcontractors shall applicable codes acceptable to local authorities.Sign 11.Unless stated otherwise on drawings,locate electrical a violation of project specifications,and shall thereby review the full content of the plans for discrepancies and All trades shall,at all times,keep the premises free from and directional indicators shall be readily discernable receptacles,cover plates,or communications relieve the architect and his consultants of damages or omissions prior to the start of work.Any discrepancies or accumulation of waste materials or rubbish caused by and located in a visually unobstructed location as connections a minimum of 15"above the finish floor repair required as a result of improper site and building omissions in the plans shall be communicated in writing their work.Subcontractors shall remove all rubbish,tools, required to clearly indicate the exit door and/or route. surface.(2015 IBC) maintenance. to the Architect at once.Subcontractors shall be scaffolding,surplus materials and leave the job in a _ responsible for any work not in conformance with the broom-clean condition. 5. Illuminated Exit Signs: 3. CODES: plans or in conflict with any code.RFIs always receive A.Visual exit signs are required whenever two exits - H expedited review and response. 19. TRADE MANUALS AND APPLICATIONS: are required(2015 IBC) Z All work shall comply with most stringent requirements of _- W all applicable city,county,state and federal laws,rules, 12.USE OF DETAIL SHEETS: The plans refer to various professional trade manuals B.The means of egress,including the exit discharge, codes ordinances and regulations.If the General and publications.The General Contractor and all shall be illuminated at all times when the building LL] Contractor or any Subcontractor performs any work in Use of the detail sheets take precedence over Subcontractors shall be familiar with and refer to the space is occupied(2015 IBC) conflict with the above mentioned laws,rules,codes,and general small scale drawings and notes take precedence trade publications relating to their work. regulations,then the Contractor in violation of said over scaled measurements. C.Exit sign faces shall be illuminated with an W requirements shall bear all costs of repair arising out of 20. STORAGE OF MATERIALS: intensity of at least 5 foot candles Of the work.A partial list of the applicable codes are listed Details and sections on the drawings are shown at (2015 IBC) J in the project drawings. specific locations and are intended to show general The General Contractor and Subcontractors shall be Q requirements throughout.It is not the intent of these responsible for storing the materials on the site according D.Provide separate sources of power for exit o Local Review and Inspection may implement additional Construction Documents to illustrate every unique to material supplier's or manufacture's instruction.The illumination for means of egress elements in building/ w N W construction assembly or detail,the General Contractor materials shall be kept secure and protected from spaces to have two exits. 2015 IBC m Z requirements. General Contractor shall provide prompt Y p p p ( ) w s j W documentation to the Architect for review and resolution and Subcontractor shall review their specific trade of moisture,pests,damage and.Any loss arising out of DISABLED ACCESSIBILITY N , of any such situations materials stored at the site is the responsibility of the General Contractor or Subcontractor who stored the A 1 0 0 damaged or lost materials. Division 1 - General Requirements Division 3 - Concrete (Refer ToDwgs For Additional Requiements) Division 6-Wood, Plastic&Composites Division 6 -Wd., Plast. &Comp Cont. Division 7 -Therm. & Moist. Protect cont. Division 8 - Openings Cont. A. Conditions A.COMPLIANCE A.Compliance 6. Countertop: Group#1(Single-Use Toilet door with privacy lock) `pllpUttlnrlldii 1, The General Conditions as published b the American Institute 1. The labor,materials and execution required for all work as 1. All frmin and car ent shall be done in accordance with A nstalf ush to adjacent surfaces with sealant'oint su ort 2 leto before roofipn inspect the icat on sroof abengnfl The ontractor Iashing,cents, s curbs, 3 ea. Hinges 4.Sx4.5 6B1191-32D(630) Hagar 25'c0......ARC r�o p Y q g,, p ry ) ) pp g pp g 1 ea. Closer P-4040XP-AL LCN 8ol U: CARLL :F s of Architects,Documents #A-201,the latest edition shall indicated on the drawings shall be in accordance with those those specific sections of the applicable edition of the securely or as noted-back-prime all exposed surfaces not responsible for remedying or causing to be remedied an 1 ea. Lockset-Privacy RHO-NDa0Sx626 Schlage = govern and be part of these documents. specific sections of the current edition of the applicable building International Building Code and details indicated in the otherwise finished p y g g y y 9 i LINGLE code. drawing. defects found at this time. Commencement of work 1 ea. Floor stop holder FS446 Ives B Plans And Specifications 7. Installation: (Set lag shield in epoxy adhesive) '. AR-231a r constitutes acceptance of existing conditions. 2 ea. Kick Plate K005012x3a-SS 630 Trimco B.Structural Lumber ( ) 1. Definition of construction plans and specifications:shall be C.CONCRETE A) Install units level and plumb with ticlht joints between any (mount kick plate on BOTH sides of door) herein defined as those plans and specifications as issued for 1. Lumber to be graded by WCLIB standard grading rules 16 or multiple units. Scribe to wall and other surfaces as 3. Roof Materials and Specifications: refer to plans for typical 1 set Frame silencers#1229A-grey(3) Trimco Construction by the architect and so designated as being 1. Cement shall conform to ASTM C 150,type 2 WWPA gqrading rules with moisture content not over 19%or less required. Fasten to studs or solid blocking with#14 wood roofing systems. issued for construction. Before construction can commence, than 7 at time of installation. screws of sufficient length to penetrate member at least 1 gGroup#1A(Multi-Use Toilet door-no lock) construction plans and specifications as issued by the 2. Fine aggregate shall be composed of clean hard particles with inch. 3 Group Hinges(Multi-Use 5 Toilet do 2D o to Hagar architect must be on the job site and a building permit must be not more than 2 percent by weight of deleterious substances. C.Rough Carpentry 9 ( > 9 issued. The plans and specifications,as reviewed and B) Make all shelving permanently straight,true and free form 4. Guarantee: the contractor will provide to the owner a written 1 ea. Closer P-4040XP-AL LCN approved by the building department with the building 3. Course aggregate shall conform to ASTM C 33. 1. Workmanship shall be first class in all respects and meet the wrap and waves. Fit all drawers snug and without binding. one year guarantee assuring a watertight roof. 1 ea. Push plate 1001-9 Ss(outside) Trimco department s seal of approval affixed to the plans must also requirements of a standard good practice normal to the trade. Warped or out-of-alignment cabinet doors are not 1 ea. Pull handle 1191-4 SS(12") Trimco remain on the job site at all times. The contractor should not 4. Combined gradin of aggregates,shall to the requirement of acceptable. Maintain a uniform clearance between 1 ea. Pull plate 1001-11 SS(inside) Trimco confuse the bidding documents with the approved plans and U.B.C.5.concrete shall have a minimum five(5)sacks of 2. Cooperate with all trades and perform all necessary cutting and cabinet drawers and cabinet frame not to exceed 1/16 1 ea. Floor stop Holder Fsaas Ives m specifications as issued for construction. cement per cubic yard and a maximum of seven(7)gallons of patching of carpentry work as required for proper attaching inch. P - w water per sack and shall attain a minimum compressive and/or pass of the work of other trades. Such work shall (Set lag shield in epoxy adhesive) m m a 2. Interpretation of the drawings and documents: each contractor strength of 2500 psi at 28 days,unless otherwise indicated on conform to requirements indicated on the drawings and/or 8. Touch-Up and Cleaning: 2 ea. Kick Plate K005012x34-sS(630) Trimco o shall check and verity all dimensions and conditions at the the drawings. specified herein. (mount kick plate on BOTH sides of door) m project site before executing anv work and shall notify the A) On completion of work,touch-up all abraded areas on 1 set Frame silencers#1229A-grey(3) Trimco owner and the architect of any discrepancies before 6. Concrete shall be mixed and delivered in accordance with 3. Pipes in Walls: stud partitions containing plumbing,heating or exposed finish work and wherever required to complete _ proceeding. The,Architect shall be notified of any unusual or ASTM C 94. other es shall be so framed and the oists underneath so the work for architect's a roval. In addition,dust and N r unforeseen conditions or situations which may affect the pipes pp Group#2(kitchen specialty doors) Y spaced as to give proper clearance for The pi in .Where a wipe clean all finished surfaces: use no harmful solutions o : m structural integrity,intent,or safetyof the project. pp q 1 set SCP-3 hardware by door mfr Eliason p 1 7. The concrete work shall be in accordance with the ACI and 318 partition containing such piping runs parallel to tf e floor joists, i and 347. the joists underneath such partitions shall be doubled and 1 pr. 9"x14"View window at 60"AFF Eliason m 3. Adherence to the plans: strict adherence to the construction spaced to permit the passage of such pipes and shall be 1 ea. 14"x16"View window at 60"AFF Eliason a documents must be maintained. No changes shall be made in g. Form work: construct forms to slopes,lines and dimensions bridged.,Where plumbing,heating or other pipes are placed in REFER TO SHEET A200 FOR TYPE SPECIFIED the project which deviate from the plans and specifications shown,plumb and straight and sufficiently tight to prevent or partly In a pa tition,necessitatincq]the cutting of the soles or without the written consent of the owner. No structural leakage. Securely brace and shore forms to prevent pplates,a metal tie not less than 1/8 thick and 1 1/2"wide shall Group#3(office door) changqes shall be made without the written consent of the displacement. be fastened to the plate across and to each side of the opening architect. With not 0SS than four 16d nails. 3 ea. Hinges 4.5x4.5 BB1199-NRP-SH-32D(630)Hagar 9. Slab base: place one layer 6 mil visqueen over 3 inches of 1 ea. Closer P-4040XP-AL LCN 4. Working Drawing: figured dimensions and detailed drawings sand. Sand to be clean yellow fill sand,total 4inches deep. 4. Apply as required caulking to all exterior frame and sill joints or 1 ea. Lockset-Storeroom RHO-ND80JDx626 Schlage shall be follower]in preference to scale measurements. In any oints of dissimilar materials whichhave the potential to leak. 1 ea. 6-pin FSIC 23-031x626 Schlage case of anYY doubt on the part of the contractor as to the exact 10. Before placement of concrete,the contractor shall verify Cau�k to be elastic,non staining applied per manufacturer's 1 ea. Lockguard-LG-12xUS32D Ives meaningotthedrawingsandthesespecifications,heshall properplacementofallitemsofallitemsofworkwhichare recommendation. Division 7 -Thermal & Moisture Protection Division 8 - Openings lea. 595xUS26D(alternate)Peek-O Home Protector apply to the architect for an interpretation before preceding embedded in the concrete work. (The footings shall have been with is work. inspected and approved by qualified soils engineer before 5. Place building paper behind all weather exposed surfaces(sills, 1 ea. Floor stop#1211-6zs Trimco concrete placement.)Footings shall be free of standing water. siding,trim,etc.).Building paper shall be free from holes and A.Membrane Waterproofing A. Compliance 1 ea. Floor stop riser#1211CL-AL(1/2") Trimco 5. Shop Drawings: see Responsibility Schedule breaks,applied weather board fashion,lapped not less than 2" 2 ea. Kick Plate K005012x34-SS(630) Trimco 11. Floor Slabs and Footings: subgrade shall be in moist at horizontal joints and not less than 6"at vertical joints. (mount kick plate on BOTH sides of door) C. Materials And Labor condition at time of placing concrete. Thickness shall be as 1. Quality assurance:waterproofing system shall comply with 1. All labor,materials and execution required for the glass p g tY p g Y p Y 1 set Frame silencers#1229A-grey(3) Trimco indicated. Concrete mix for slabs shall be of a workable D.Finish Carpentry volatile organic compound OC requirements of IARB and glazing work as indicated on the drawings shall be in 1. Unless otherwise stipulated,the contractor shall provide and consistency to meet structural requirements but shall not allow g p N ) q pay for all material,labor,water,tools,equipment,li ht and any water to accumulate on the surfaces. Screed and 1. All millwork and finish carpentry shall be manufactured in (International Air Resources Board) accordance with those specific sections of the latest edition of power,transportation and other facilities necessary or the thoroughly tamp concrete with a grid type tamper to raise a thin accordance with the best standards of the trade and include the applicable building code. Group#4(rear service door) execution of the work. bed of mortar to surface with a wood float. Steel trowel to a but not be limited to the following: 1 ea. Cont.Hinge 780-226HD 83"AL Roton smooth hard finish or finish as directed by architect 2.Products (use 780-45HD AL for existing conditions) 2. The contractor shall provide all shoring and bracing required to A)Exterior door jambs,stops and trim. 2. Glazing practices shall conform to appropriate provisions 1 ea. Panic/Exit device 3790-EO-US26D First choice protect personnel and adjacent property and to insure safety of 12. Dry pack shall be one part portland cement and two parts of the"Glazing Manual"of the Flat Glass Jobbers Association. the project work. sand with only sufficient water to permit hand packing. B)Exterior window trim A) Waterproofing Membrane:membrane waterproofing shall g (NO dogging function accepted) be bithuthene system 4000,by W.R.Grace&Co.and 1 ea. Interchangeable Core Cylinder-Rim Schlage 3. Wherever in these drawings any material of process is D.REINFORCING STEEL C Exterior buildingtrim 3. Provide hardware preparations and reinforcements for 1 ea. 6-pin FSIC 23-031x626 Schlage indicated,it is for the purpose of facilitating description of the ) shall include mastic joint treatment and other accessories p p 1 ea. Cylinder Pull 121L-US32D Hagar material or process desired. The contractor may offer any 1. Reinforcing steel shall be deformed bars conforming to ASTM D)Handrails as recomended by manufacturer. each item indicated as directed by the ANSI/SDI 250.8-2014 1 ea. Closer(H)P-40a0XP-30a9EDA-AL LCN material or process which shall be deemed equivalent by the A-615 grade 40. Welded wire mesh to be ASTM A-185. standard specification. 1 ea. Astragal FH-z7xMlLxs Hagar engineer and the owner to that material or process indicated or Reinforcing steel shall be lapped 30 diameters or 12", E)Interior jambs,stops,trim,base,etc.g 1 ea. Drip cap(full width)16A NGP specified. whichever Is realer. B) Vapor Barrier: two sheets of kraft paper laminated with F)Closet shelving asphalt embedded with tri-directional glass reinforcing B. Products 1 ea. 595xUS26D(alternate)Peek-O Home Protector 4. Unless otherwise specified,all materials shall be new both 2. Reinforcing steel shall have a minimum protective concrete 1 ea. Armor Plate K0012x3EC 36630) Trimco workmanship and materials shall be the best of their respective covering as noted below: G)Pocket door frame and track fibers,extrusion-coated with polyethylene;accessories as 1 ea. Kick Plate K00501side of or) Trimco kinds.The contractor shall if required furnish satisfactory recommended by manufacturer. 1. Exterior Entry Doors (mount on exterior side of door) evidence as to the kind and quality of materials. Bottom of footing pads: 3 inches 2. Jambs,stops,base,etc.:select finger joint pine or fir,kiln dried Provide OLDCASTLE medium stile aluminum doors 1 set Frame silencers#1229A-grey(3) Trimco 5. It shall be the duty of the general contractor to see that all Wall steel below grade: 3 inches 3. Closet shelves,linen shelves: premium grade,pine or fir C) Below grade retaining wall waterproofing:"Swellite" (MS-375)with Douglas Fir Natura Finish 1 ea. Weather strip 172N-DkB NGP subcontractors are fully informed in regard to the general shelving,cleats,nosing,etc.,for opaque finish. membrane composite system with volcla bentonite sand Contact:Drew Scott-Oldcastle Building Envelope(OBE) 1 ea. Door Bottom 319EV NGP conditions and preliminary specifications. Wall steel below grade exterior grade: 1-1/2 inches p y Y 1 ea. Threshold 413-SIA NGP g g butyl rubber layers as manufactured b American Colloid 803 Airport Road,Terrell,TX 75160 D. Protection Of Work And Property 4. Nailing: use only hot dip galvanized or aluminum finish or tY Y Y (327-SIA at floor transition as req'd.) NGP p Y Wall steel above grade interior face: 3/4 inches casing nails. Set nails for putty stopping in surfaced members. Company. (972)551-6100 1. The contractor shall be responsible for all violations of city Hammer marks not acceptable on any exposed surface and Group#5&Group#6 hardware items will be supplied with the entry doors p t' Formed slabs: 3/4 inches may be cause for rejection of work by the architect/owner. See the Products part of this section for further information. ordinances and state laws involved in the performance o his D) Backfill protection/drainage:"Hydraway 300"combination 2. Exterior Service Door work. He shall provide,Burins the progress of his work,every 3. All vertical bars in walls,columns and piers shall be doweled to 5. Splices: Mitre all splices and mitre all ends and returns. Install drainage/protective board as manufactured by Monsanto G.C. to provide Hardware. Landlord to provide 1-3/4" G.C. is responsible for thresholds,door glazing and installation and all safeguards and protection against accidents,injury and footing with bars of the same size,spacing and/or locations as members in as long of lengths as possible. full galvanized,insulated,Level 2,Model 1,hollow metal damage to persons and properittyy including adI'oining property. vertical bars. or approved equal. y 9 Group#5(entry door single) The contractor shall be responsble for his work and every part 6. Quality: Install work as shown. Plumb level,aligned,and door with 16 gauge edge channels&reinforcing rails and 18 1 ea. Threshold 327-SIA NGP thereof,and for all materials,tools,appliances and property of 4. Welding or reinforcing bars not permitted except as detailed securely anchored. make scribes where required. Miter face sheets (field verify ADA compliance and applicability) every description used in connection therewith. and shall be done with series E-60 electrodes low hydrogen) corners of trim unless noted otherwise.Ease all outside corners gauge ( Threshold provided and installed by G.C. 2. The contractor assumes all risks,hazards and conditions in with thoroughly dry coatings. and edges. 3.Installation: Inspect surfaces prior to installation to verify that connection with the performance of the contract,and even if 5. Reinforcing steel,anchor bolts,dowels,inserts,etc.shall be 7. Miscellaneous they meet manufacturer's recommended criteria and install 3. Interior Doors 1 ea. Cont.Hinge-DFM83SLIHDI-CL Pemko the performance of the contract involves a greater securely tied in place before concrete is poured. Coordinate following manufacturer's directions. Provide 1-3/4"5-ply solid core(mineral or block)doors with (match existing storefront finish) expenditure of money than the contractor expected at the time location of dowels for mason contractor rior to placing A)Flashing paper: 2 oz.copper armored Sisalkraft. sanded stain-grade faces-prime top,bottom,hinge 1 ea. Closer(H)P-4110XP-3049EDA-AL LCN of the bidding,no allowance will be made on account thereof footings. These dowels mush a accurately placed. 1 ea. Panic/Exit device 3690-EO-US26D First Choice and the contractor shall continue with and complete the work. B)Wood siding backing: 15#asphalt saturated felt. mortises and lockset cut-outs before installation (NO EXTERIOR CYLINDER) E. Submittals 6. Anchor bolts shall be ASTM A-307 or equal quality. C Glue: waterproof for all exterior use. B.Sheet Metal 1 ea. Interchangeable Core Cylinder-Rim for dogging Schlage P 4. Door Frames 1 ea. 6-pin FSIC 23-031x626 Schlage 1. Subcontractors shall submit samples,in conjunction with the D)Caulking: A.C.Horn,Vulcatex,polymerized oil base,non 1. Compliance: Provide Level 2,Full Profile Welded Frames with a material 1 ea. Door pull 215L-630 Rockwood Responsibility Schedule. Division rJ - Metals staining caulking compound or approved equal. thickness of 0.053 inches(1.3 mm)[Manufacturers 1 set Astragal seal OBE p E Closet pull and supports: 1 1/2"diameter fir. Accessories A Architectural Sheet Metal Manual published b the Sheet g ] g 2 ea. Kick Plate K005012x34 AL Trimco F.Supervision Standard Gauge 16 and hardware reinforcing as directed J P. pp ) P Y (mount kick plate on BOTH sides of door) 1. The contractor shall give personal supervision to thework,using A.Miscellaneous Metal as required. Metal And Air Conditioning Contractors National by ANSI/SDI A250.8-2014,Table 4. 1 ea. Door Bottom V-231 OBE 0 his best skill and attention and shall keepcompetent foreman a p F)Pocket door frame and track: standard for 2x4 stud wall. Association,Inc,hereinafter referred to as the"Sheet Metal and necessary assistants constantly on site. The foreman Install Hold-Open H closers to restrain the door at the widest Lu shall be the personal representative of the contractor and all 1. Supply and install all miscellaneous metalwork as shown on the Manual". (SMACNA) P ( ) p p E.Casework swing possible-avoid conflicts with frame or other items. croup#s(entry door pair) directions given by him shall be as binding as if given by the drawings and as specified herein,including all anchorage g p 1 ea. Threshold 327-SIA NGP LLI � contractor. Communication delivered to t e foreman by the devices,etc. 1. Standards: B) International Building Code,latest edition (field verify ADA compliance and applicability) architect shall be as binding as if delivered to the contractor. Interchangeable Cores(IC)-Provide Two(2)complete spare Threshold provided and installed by G.C. Lu A) All casework and cabinet work shall be manufactured in sets of interchangeable cores with four 4 keys each for ! l o 2. Submit shop drawings of all work herein showing layouts,sizes, accordance with standards of the Woodwork Institiute of 2. Sheet Metal: galvanized iron,hot dipped in accordance with 9 ( ( ) Y ) C• G.Changes In The Work methods of construction and installation,including sizes and California(WIC)custom grade. ASTM A-163-39 standards,26 gauge unless shown or hardware specified to receive IC. Label each core for hardware 1 ea. Cont.Hinge-DFM83SLIHDI-CL Pemko w H 1. The owner,without invalidatin the contract,may alter b (match existing OXP-3o4 EDA- g Y Y es of all fastening devices. B An lastic laminate finishing required in the work shall specified otherwise. To the best grade produced. group and lock type for which it is a spare. Provide two(2)IC 2 ea. Closer H P4110XP-3049EDA-AL LCN �Y LL.I o W adding to or deducting from tF e work covered in the contract. types g ) n p g q g p ( ) All such work shall be executed under the conditions of the conform to applicable requirements of the Architectural control keys-package spare interchangeable cores and keys, 1 ea. PaniGExit device 3692-US26D First choice Woodwork Institute"quali y standards"for"custom"grade. control keys,and core interchange instructions in clear) labeled 1 ea. Panic/Exit device 3690-EO-US26D First choice Original contract except that no extra work or charges shall be 3. Verify all dimensions by taking field measurements: proper fit 3. Solder Metal: ASTM,B32,standard brand,grade A of equal Y , 9 Y J done without written order from the architect. Such orders shall and attachment of all items is required. C) Materials shall be new and all lumber or wood shall be in parts tin and lead. durable container and deliver to Owner's representative. (NO EX TERIOR CYLINDER) =z ¢ - cover the agreed price and terms of extra work or changes. If accordance with WIC finished wood and cabinet materials 2 ea. Interchangeable Core Cylinder-Rim for dogging Schlage W} - J work is to be omitted,then proper credit for such omitted work shall have moisture content not exceeding 12%by weight. 2 ea. 6-pin FSIC 23-031x626 for dogging cylinders Schlage Z n Z - shall be given the owner. 4. Clean all welds and remove spatter,leaving finished product 4. Fasteners: nails,bolts,rivets,etc.to be the same material as Contact Habit LLC Operations Division for keying/master keying 1 ea. Cylinder-rim for locking Schlage Q, 2. Job Measurements: take such field measurements as may be that being fastened. instructions. 1 ea. 6-pin FSIC 23-031x626 for locking cylinder Schlage U m H.Cleaning Building And Premises clean,smooth and ready for priming. required and be responsible for them. Report any major 2 ea. Door pull 215L-630 Rockwood 1. Prior to the completion to the work,the contractor shall discrepancies between drawings and field dimensions to 1 set Astragal seal OBE p architect. 5. General: form all sheet metal items accurate) to dimensions thorough)v clean the exterior and interior of the building , 5. Prime all surfaces thoroughly or provide hot dipped galvanized Y a ea. Kick Plate K0050 12x34 AL Trimco including tixtures,,equipment floors and hardware,removing all coating per ASTM At23. 3. Exposed Materials: and shapes detailed or as shown in the sheet metal manual. (mount kick plate on BOTH sides of door) plaster spots,stains,paint spots and accumulated dust and cope to an accurate fir and securely solder intersecting 2 ea. Door Bottom V-231 OBE dirt. This shall include thorough cleaning of all roofs,window A)Exposed solid lumber shall be dry and sound,selected to sills and ledges,horizontal projections,steps rails sidewalks or eliminate all defects,species of softwood premium grade members. turn back exposed edges 1/2"or as shown. other surfaces where debris may have collected. Nash and will be admitted. Provide for expansion and finish water and weather tight Group#s&#s Door si na e polish all glass. P 9 9 B)Exposed doors and drawer fronts to be cut from 3/4" throughout. Provide permanently affixed signage at each public-use exterior door _ I.Guarantees multifiber(high density particle board) use 1 inch high letters to contrast with background,which reads: 6. Caulking: completely seal with caulkingall sheet metal joints THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED 1. Except as otherwise specified,all work shall be guaranteed in 4. Semi-exposed Materials: p y - W writing by the contractor against defects resulting from exposed to the weather,unless such joints are to be soldered - LLI defective materials,poor workmanship or faulty equipment,for A) Semi-exposed solid lumber or lumber visible when cabinet tight and continuous. Group#7 r a period,of one year from the date of Tiling the notice of Is Open,shall be dry and sound,selected to eliminate p (rear emergency exit door) _ completion an f the acceptance of the building)by the owner. defects. Any species of softwood premium grade will be 1 ea. Cont.Hinge 780-226HD 83"AL Roton U) If within the guarantee period correction of faulty materials or admitted. 7. Down spouts and leader heads shall be min.20 GA.G.I. (use 780-45HD AL for existing conditions) ^^ N workmanship is necessary in the opinion of the owner,the 1 ea. Panic/Exit device CDA3790-36-CL First choice contractor shall promptly,upon receipt of notice from the B Semi-ex osed shelves or other areas visible when cabinet installed where shown and detailed on the drawings. Z owner and without ex ense to the owner,correct faulty ) p (NO dogging function accepted) P tY is open shall be board or"A"grade plywood,suitable to 1 ea. Closer(H)P 40a0XP-3049EDA-AL LCN O materials or workmanship. receive paint finish. C.Roofing 1 ea. Astragal FH-27xMILxS Hagar H J.Verification Of Underground Utility Improvements 5. Concealed Materials: 1 ea. Drip cap(full width)16A NGP U 1. Compliance: 1ea. Kick Plate-K005012x3a Trimco 1. The general contractor shall provide the owner with an as-built A) Concealed solid lumber shall be any species containing 1 set Frame silencers#1229A-grey(3) Trimco ILL_ drawing locating and describing all underground utilities no defects which materially affect strength or utility of the 1 ea. Weather strip 172N-DkB NGP located on the site,including but not limited to,the followiT: piece. A) All roofing and flashing materials shall be installed in strict 1 ea. Door Bottom 319EV NGP U gas lines,water lines sanitary sewers,telephone lines,and m electrical lines and site drainage. B)Concealed plywood shall be any species containing no conformance with the manufacturer's specifications and in 1 ea. Threshold 327-SIA NGP o N W defects which materially affect the strength or utility of the accordance with specific sections of the latest edition of 1 ea. Emergency Exit Sign-alarm First Choice w piece. Front surfaces of back panels ofbase cabinets 37" the applicable building code. 0)1 or less in height shall be solid. A110 Division 9 - Finishes Division 9 - Finishes contd Division 10 - Specialties Division 10 - Specialties contd Division 22 - Plumbing SEESHEETP100 A.Lath And Plaster-NOT USED 4. Acceptable Manufacturer's: Bath And Toilet Accessories 9.MATERIALS,GENERAL Division 23 - HVAC SEE SHEET M100 \`omumurrnuoiz A Stainless Steel: AISI Type 302/304,with polished No.4 25eq ARoh;�P, A) Except otherwise specified,materials shall be the products ) Yp B. Gypsum Wallboard of the following manufacturer's: 1. RELATED DOCUMENTS finish,0.034 inch(22 gauge) minimum thickness. U4' cAAI L 'rFo yp A) Drawings and general provisions of the Contract,including B) Brass: Leaded and unleaded,flat products,ASTM B 19; Division 26 - Electrical SEE SHEET E100 LINGLE 1.Compliance: 1.) Paint: Cl,I Benjamin Moore or equal General and Supplementary Conditions and Division 01 rods,shapes,forgings,and flat products with finished 'Nib AR1 r 2.) Stain: Olympic or equal Specification Sections,apply to this Section. edges,ASTM B 16;Castings,ASTM B 30. A) All work performed under this section must conform to 3.) Oils,thinners,dryers and tinting colors: shall be of the B) Specifications throughout all Divisions of the Project C) Sheet Steel: Cold rolled,commercial quality ASTM A 366, highest quality and shall be approved by the Manual are directly applicable to this Section,and this Section is 0.04 inch(20 gauge)minimum. Surface preparation and applicable portions of the governing local codes. manufacturer of the paints and stains being used. direct) applicable to them. metal pretreatment as required fora lied finish. B) All work shall be governed by the standard specifications for g Materials selected for coating systems for each type surface Y pp q pp the application of sum wallboard backing, ) g y tYp D Galvanized Steel Sheet: ASTM A 527,G60. pp gyp g,including shall be the product of a single manufacturer. 2. REFERENCE STANDARDS- items in this division shall E) Chromium Plating: Nickel and chromium electro deposited finishing,(ANSI A117.1-2009)of the American National meet the requirements of specific sections of the current edition of ) on base metal,ASTM B 456, Type SC 2. p Standards Institute. G. Glass the 2015 International Building Code. F) Baked Enamel Finish: Factory applied,gloss white,baked 2. Inspection: inspect all surfaces and supports which wallboard 1. Verify with architectural floor plan and exterior elevations if new A) The latest published edition of a reference shall be acrylic enamel coating. _ m is to be applied. Remedy or cause to be remedied all storefront and glazing will be installed on project.Fixed glass in applicable to this Project unless identified by a specific edition G) Stainless Steel Mirror Surfaces: Not less than 0.04 inch(20 m a conditions which may jeopardize satisfactory wall finish before date. gauge)AISI Type stainless steel sheet,stretcher leveled ❑ Y 1 p ry exterior metal envelope will be used if new storefront is required installation of drywall. Commencement of work under this for job. In warm climate locations(CA,FL,NV etc..)the fixed B) All reference amendments adopted prior to the effective with No.8 polished mirror finish.Bond to 1/4 inch minimum m m section constitutes acceptance of conditions and places glass shall be 1/4"clear tempered glass where area is not more date of this Contract shall be applicable to this Project. hardboard backing. N m responsibility for satisfactory finish work on this contractor. than 27 sq.ft.as shown on the drawings,and 3/16"clear of C) All materials,installation and workmanship shall comply H) Galvanized Steel Mounting Devices: ASTM A 153,hot dip ❑ m J glass wherever glass is within 18"of a floor or more than 27 sq with all applicable requirements and standards. galvanized after fabrication. 3 " " 3. Wallboard and Materials: ft. In cold climate locations(UT,NJ,VA,WA,etc..)the fixed 1) Fasteners: Screws,bolts,and other devices of same 3. QUALITY ASSURANCE material as accessory J a glass shall be 1"insulated tempered glass in lieu of thinner ry unit,or of galvanized steel where A) ASTM C-36 and ASTM C-442 manufactured by U.S.Gypsum single pane glass. In no case shall glass exceed the sheet size A) Inserts and Anchorages: Furnish accessory manufacturers' concealed. or approved equal. limits set forth in local governing code.Glass to meet or standard inserts and anchoring devices that must be set in 1) Non-firerated wallboard to be the thickness indicated on exceeded required thickness and type(insulated,tempered, concrete or built into masonry.Coordinate delivery with other Work A) No names or labels are permitted on exposed faces of the drawings wide type SW sheet rock in lengths as laminate impact,etc.)set forth in all local governing codes. to avoid delay. toilet and bath accessory units.On either interior surface required with tapered long edges. B) Single Source Responsibility: Provide products of same not exposed to view or on back surface,provide 2) Fire-rated wallboard: sheet rock firecode to be 5/8"type 2. All glass within 18"of floor lines and not less than 18"in any manufacturer for each type of accessory unit and for units identification of each accessory item either by a printed, X x 48"side by lengths as required type SW with tapered dimension shall be tempered or laminated. exposed to view in same areas,unless otherwise acceptable to waterproof label or a stamped nameplate indicating edges. Ivory manila paper finish,suitable for paint, Architect. manufacturer's name and product model number. 3. All glass within a 24 inch arc of either vertical edge of any door wallpaper,etc. shall be tempered,if the bottom of the glazing is less than 60 B Screws/nails: ass specified on the plans,in these 4. SUBMITTALS B) Surface Mounted Toilet Accessories,General: Except p p inches above the walking surface.specifications or as required by local codes A) Product Data: where otherwise indicated,fabricate units with tight C) Joint reinforcing tape: perf-a-tape,cross fibered paper with 4. Mirrors to be PPG or AAE,1/4"polished plate glass with backs 1. Submit a complete listing of all manufacturers,products, seams and joints,exposed edges rolled. Hang doors or many small random perforations, silvered two coats,heavily electroplated with copper,prime model numbers,and designs proposed for use in the Work of this access panels with continuous stainless steel piano hinge. D) Joint compound:perf-a-tape,all purpose ready mixed coated with mirror backing paint. Install mirrors with metal Section. Provide concealed anchorage wherever possible. compound. runners at top and bottom. B) Record Documents: E) Cover coat: USG cover coat compound 1. Maintain two copies of all shop drawings,product data,and C) Recessed Toilet Accessories,General: Except where F) Metal accessories 5. All windows and sliding glass doors shall be certified and samples,manufacturer's specifications, otherwise indicated,fabricate units of all welded G) Corner beads: no.101 dur-a-bead(all metal)1"x 1"flanges. labeled to meet ANSI infiltration standards. recommendations,installation instructions,and maintenance data construction,without mitered corners. Hang doors or H) Metal trims: 200 series,200-A"U"shaped channel at the Project Site. At Project Closeout,turn over both copies to access panels with full length,stainless steel piano hinge. H. Finish Hardware the Architect who will transmit one copy to the Owner. Provide anchorage that is fully concealed when unit is 4. Joint Treatment and Finish: closed. A) Mix or prepare joint compound according to manufacturer's 1. Door hardware shall be provided for all mandoors as normally 5. PROJECT CONDITIONS recommendations. required. All mandoor hardware to be selected by the owner. A) Coordination: Coordinate accessory locations,installation, D) Framed Mirror Units,General: Fabricate frames for glass B) Provide Level 4 finish,per Gypsum Association publication and sequencing with other Work to avoid interference with and mirror units to accommodate wood,felt,plastic,or other 2. Submit hardware schedule to owner for approval. ensure proper installation,operation,adjustment,cleaning,and lass edge protection material. Provide mirror backing GA-214-10,on all surfaces exposed to view. P P P 1 9� 9 9 P 9 C) Provide Level 2 finish for concealed areas and areas servicing of toilet accessory items. and support system that will permit rigid,tamperproof scheduled to receive additional materials for finish surface. 3. Installation of Hardware: install hardware accurately fitted to glass installation and prevent moisture accumulation,as doors and frames adjusted to operate smoothly and without 6. Products-General follows: sticking and binding. After fitting,remove all hardware,except A) All materials shall meet or exceed all applicable referenced 1. Provide galvanized steel backing sheet,not less than C.Ceramic Tile prime coat butts,for painting and reinstall and adjust after painting is complete and accepted. standards,federal,state and local requirements,and conform to 0.034 inch(22 gauge)and full mirror size,with non 1. Compliance: unless otherwise indicated on the project codes and ordinances of authorities having jurisdiction. absorptive filler material. Corrugated cardboard is not drawings or supplemented or modified herein,all material and an acceptable filler material. the installation and workmanshipfor ceramic tile shall comply 7. Manufacturers E) Mirror Unit Hangers: Provide system for mounting mirror with applicable requirements of the American National A) Product numbers scheduled below are products of the units that will permit rigid,tamperproof,and theft proof Standards Institute(ANSI)and the Tile Council of America Bobrick Washroom Equipment,Inc.unless noted otherwise. installation,as follows: Handbook for Ceramic Tile Installation, 1. One piece galvanized steel,wall hanger device with 8. Toilet Accessory Schedule spring action locking mechanism to hold mirror unit in 2. Submittals: submit one sample panel,at least 12"x 12" of the The Item numbers listed correspond to the Toilet Accessory position with no exposed screws or bolts. color,size,and grout color specified for approval by owner. Schedule located on sheet A250,not all of the listed items will 2. Heavy duty wall brackets of galvanized steel,equipped be used for each project location -Refer to sheet A250 for with concealed locking devices requiring a special tool 3. Environmental conditions: maintain temperature at 50 degrees the required items-unless otherwise noted every item shall to remove. F.minimum during tile work and for 7 days after completion. be supplied and installed by the Contractor F) Keys: Provide universal keys for access to toilet Vent temporary heaters to outside to avoid carbon dioxide 1. Mirror-polished 1/4"plate glass with Stainless Steel accessory units requiring internal access for servicing, damage to new tilework. polished finish frame. re-supply,etc. Provide minimum of six keys to 4. Extra Stock: supply 2%of each tile used in clean marked Bobrick B-165 18 x 36 Owner's representative. J cartons for owner's use. 2. Satin Stainless Steel Purse hook Bobrick B-6707 10.INSTALLATION o 5. Mortars and Grouts: 3. Hand Soap Dispenser-Owner furnished,Contractor installed w A) All mortar mixtures and materials used shall be in 4. Paper Towel Dispenser-Owner furnished,Contractor installed A) Installation shall meet or exceed all applicable federal,state W CIO accordance with current editions of 5.Satin Stainless Steel Semi-Recessed trash receptacle and local requirements,referenced standards and conform ANSI A108,1:A108.2 and A108.3-1967. Bobrick B-43644 to codes and ordinances of authorities having ry B) Standard specifications for ceramic tile installed with 6. Satin Stainless Steel 36 inch long Grab Bar jurisdiction. o Portland cement mortars as published by Tile Council of Bobrick B-5806 Series(1 1/4"diameter) w F- �2 America. Cement shall be either white,gray or colored as 7. Satin Stainless Steel 42 inch long Grab Bar B) All installation shall be in accordance with manufacturer's °D required and directed b architect. Bobrick B-5806 Series 1 1/4"diameter ~Y w W q y ( ) published recommendations. 7A.Satin Stainless Steel 18 inch Vertical Grab Bar m¢ ; vj U 6. Performance: Bobrick B-5806 Series(1 1/4"diameter) C) Install toilet accessory units according to manufacturers' =Z J ¢ - A) Conventional mortar method: set,grout,and clean tile in 8. Satin Stainless Steel Recessed Toilet Tissue/Seat Cover instructions,using fasteners appropriate to substrate as - J accordance with(ANSI)A117.1-2009 for glazed tile. All Dispenser and Feminine Napkin Disposal recommended by unit manufacturer. Install units plumb W:5-- horizontal and vertical joints continuous. Bobrick models as required per plan location(see A250) and level,firmly anchored in locations and at heights B) Set bath accessories as provided by others. B-3574 at Women's-Right-side mount. indicated. B-35745 at Women's-Left-side mount. F.Painting B-3474 at Men's-Right-side mount D) Secure mirrors to walls in concealed,tamperproof manner 1. Extent of work: B-34745 at Men's-Left-side mount with special hangers,toggle bolts,or screws. Set units A) Specifications cover the complete painting,staining and 8A.Satin Stainless Steel Recessed Toilet Tissue Dispenser plumb,level,and square at locations indicated,according finishing of all wood,drywall,unfinished metal and other Bobrick B-3888 to manufacturer's instructions for type of substrate involved. In - surfaces throughout the building,except as otherwise 8B.Satin SS Recessed TP Dispenser/Feminine Napkin Disposal specified. Bobrick B-3094 E) Install grab bars to withstand a downward load of at least - fV B) The painting contractor shall supply all labor,materials and 8C.Satin Stainless Steel Recessed Seat Cover Dispenser 250lbs,complying with ASTM F 446.1. F_ equipment necessary.They shall examine the specifications Bobrick B-3013 - W for the work of the other trades and shall familiarize 9. Baby Changing Station 11.ADJUSTING AND CLEANING = themselves with provisions regarding their painting. They Koala Kare KB-200-05 Horizontal wall-mounted Cn shall understand that all surfaces left unfinished by the 10. Satin Stainless Steel Coat Hook(door or partition mounted) A) Adjust toilet accessories for proper operation and verify that Cn requirements of other sections,shall be finished as part of Bobrick B-6827 mechanisms function smoothly. Replace damaged or Z the contract. 11. Satin Stainless Steel Toilet Partitions defective items. 0 Hadrian Stainless Steel Metal Toilet Partitions:Head rail 0 2. Workmanship: all work shall be done by experienced,skilled braced standard stainless steel w/type 304,#4 B) Clean and polish all exposed surfaces strictly according to Q craftsman. Surface correction and preparation shall be in brushed finish manufacturer's recommendations after removing temporary U accordance with the standards set by Painting and Decorating labels and protective coatings. Contractors of America. 3. Colors: all colors shall be selected and approved by the m o N W architect or owner. N W Al 20 \�p0Y1�p1IAIIIG DOOR TYPES PARTITION LEGEND FLOOR PLAN GENERAL NOTES: ��5.••• •.h��!� a U: CARLL - - WALL TYPE SYMBOL 1. ALL DIMENSIONS ARE TO THE FACE OF DRYWALL UNLESS OTHERWISE NOTED. _=+ LINGLE 9" 1 (SEE SHEET A300 FOR 2. REFER TO SHEETS G120&A250 FOR ALL ACCESSIBLE REQUIREMENTS AND AR-2319 PARTITION TYPE DETAILS) PARAMETERS. ` q 3. PROVIDE HEALTH DEPT INSPECTION FOR ALL UNDERGROUND PLUMBING PRIOR TO CITY INSPECTION. 1 4. ALL DOORS&FRAMES TO BE NEW UNLESS NOTED OTHERWISE. 5. WALL MOUNTED BOB FLAT PANEL MONITORS:PROVIDE MINIMUM BLOCKING OF 48 INCHES SQUARE AROUND WALL MOUNTED KDS FLAT PANEL MONITOR OUTLETS. SEE ELECTRICAL HHT I STALLLER EI DRAWINGS WITH ADDITIONAL INFORMATION. G.C.TO COORDINATE MOUNTING OA O O OD O r in 6. COUNTER MOUNTED KIDS FLAT PANEL MONITORS:SEE ELECTRICAL DRAWINGS FOR INTERIOR DOOR TYP KITCHEN DOOR INTERIOR DOOR TYP EXTERIOR DOOR ttP EXTERIOR DOOR TYP ADDITIONAL INFORMATION, G.C.TO COORDINATE MONITOR LOCATION WITH �m °`a FLOOR PLAN KEYED NOTES: INSTALLER, TO SHEET All =DOOR NOT USED DOOR SCHEDULE FORE DOOR HARDWAREO �'n m EXISTING DEMISING WALL TO REMAIN-FIELD VERIFY COMPLIANCE WITH(1) 49'-5Y4"V.I.F. f N DOOR DOOR DOOR FRAME FRAME HOW. O HOUR FIRE RESISTIVE CONSTRUCTION REQUIREMENTS-APPLY MATERIALS AND m r NO, ROOM ROOM DOOR SIZE TYPE MATERIAL FINISH MATERIAL FINISH GROUP FINISHES AS NOTED FOR PARTITION TYPES SHOWN ON A300-PROTECT o z .. 7 KITCHEN/FOOD PREP 3'-0"w X B STAINLESS BRUSHED SS SS 2 DURING CONSTRUCTION.G.C.REQUIRED TO PATCH AND REPAIR IF NECESSARY. 8-6" 11-4Ya' 8-11Y" 1°-4Y 3 w i" O T-0 H STEEL SS O PROVIDE FIRE TREATED WOOD BLOCKING AT ALL WALL MOUNTED ITEMS SUCH 2 AS SHELVING,TOILET ACCESSORIES,FTC. PROVIDE METAL STRAPPING AS J a i P,' 1t170HE?JfD.N11G 3'- X B STAIN d3VS�+J SS S Se ', I REQUIRED ON EXISTING DEMISING WALL. I '7 H STEEL ` O G.C.SHALL PROVIDE AND INSTALL BLOCKING IN WALL FOR BABY CHANGING KITCHEN DOORS TO BE ELIASON TYPE SCP-3,SUPPLIED AND INSTALLED BY G.C.-FRAME TO BE STAINLESS ST E 3 STATION-SEE DETAIL 5/A250 FOR ADDITIONAL INFORMATION. MATCH DOOR FINISH FROM MANUFACTURER-DOORS AND FRAME TO BE PROTECTED FROM DAMAGE DURING CONS-FUC'HON. E ,CE DOOR 3'-0'W X HM SE£ ,M SEE G.C.TO PROVIDE AND INSTALL METAL STRAP BLOCKING IN WALL BEHIND HOOD Q EXS7NG- I7' H NDtf& NOTES ® &18'TO EA.SIDE OF HOOD FOR EQUIPMENT RESTRAINT CABLES.COORDINATE 6O EXACT LOCATION WITH EQUIPMENT VENDOR. O WOMEN'S RESTROOM 3'-0"W X A WD BIRCH- HIM SEE 1A F.S.E.C.SHALL INSTALL TENANT FURNISHED STAINLESS STEEL WALL PANEL T-0'H FF NOTES OS THROUGHOUT KITCHEN AREA(INCLUDING BEHIND COOK LINE AT EXHAUST .I � 14 ' O MEN'S RESTROOM 3'-0'W X A WD BIRCH- HIM SEE 1A HOOD)UNLESS NOTED OTHERWISE. 4,0 , ® 1 4 T_p"H FF NOTES n 2OFFICE 3'-0"W X C HM PAINT- HM P1 3 BOTTOM 12"OF ALL WALLS IN ANY WET AREA SHALL RECEIVE 5/8"BURDICK. - 4'-6" 6 5 PROVIDE MOISTURE 1 10 7'-0"H P1 G.C.TO PROVIDE AND INSTALL 5/8"PLYWOOD THROUGHOUT FOOD PREP FROM RESISTANT GYP. 8 OREAR ENTRY 3'-0"W X D ALUM PREFIN FF FF 6 0 1'-0"A.F.F.(ON TOP OF BURDICK)TO 6"ABOVE LAY-IN TILE CEILING.SEE BOARD BEHIND �+ O (EXISTING) 7'-0"H SHEET A300 FOR ADD.INFO. 2 13 3 O ENTRY(EXISTING) PR.3'-0"W X D ALUM PREFIN FF FF 6 ® G.C.TO PROVIDE AND INSTALL WATER RESISTANT GYP.BOARD THROUGHOUT FREEZER/COOLER p_7Ya" R`-(�6}� .0 14A I T-0"H RESTROOMS FROM 1'-0"A.F.F.(ON TOP OF DUROCK)TO CEILING.SEE SHEET I� A300 FOR ADDITIONAL INFORMATION. \\\�7 1 I *ALL ENTRY DOORS AND ALL GLAZING WITHIN 18 INCHES OF THE ENTIRE DOOR SWING SHALL HAVE TEMPERED 7 GLAZING-DOOR#2 TO BE EXTERIOR SERVICE DOOR BY LANDLORD OWNER/VENDER TO PROVIDE&INSTALL BLACK ALUMINUM OUTSIDE CORNER 2'-7" 3'-6 5'-2Y" I FINISH DESIGNATIONS 9 GUARD ON ALL OUTSIDE CORNERS OVER SCHEDULED FINISH IN DINING AREA. 19 REFER TO BA2 ON FINISH SCHEDULE ON SHEET A231 FOR ADDITIONAL ALUM=ALUMINUM HIM=HOLLOWED METAL SS=STAINLESS STEEL SIM. FOOD "i I INFORMATION. - FF=FACTORY FINISH PREFIN=PREFRINISHED WD=WOOD ® ^ NOTE: EVERY DOORS SHALL MEET THE FOLLOWING ADA REQUIREMENTS PERTAINING TO WORKING FORCE 10 WATER HEATER ON 5-1/2"TALL DOING PAD WITH EPDXY FLOORING TO RUN !\ ON DOOR CLOSERS. OPERATING FORCE AT EACH: EXTERIOR DOORS TO BE BETWEEN 10-15 LBS OF UP AND OVER PAD CONTINUOUS WITH FOOD PREP FLOOR-SEE 8/A400. 2'-7Y" FORCE. INTERIOR DOORS CANNOT EXCEED AT 15 LBS OF FORCE MAX. 11 5-1/2'GONG.PAD FOR SERVICE COUNTERS-SEE DETAIL ON 5&6/A400 FOR ADD.INFO. 6'-5" 4'-9" 3'-6" 3'-8" 4'-0" NOTE:ALL EXIT DOORS SERVING GROUP"A"OCCUPANCIES SHALL BE EQUIPPED WITH PANIC AND FIRE HARDWARE. - 2'-7" 2 I 12 4"CONCRETE PAD FOR EXPO COUNTER-SEE PARTITION TYPE 11 ON SHEET r 19 -- T 1 14 EXIT DOORS ALSO SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,ANY SPECIAL KNOWLEDGE,OR 1300 AND SHEET FS230 TO CONFIRM CURB DIMENSIONS I I 5" 1 6 EFFORT. KEY LOCKING HARDWARE MAY BE USED ONLY ON ONE MAIN EXIT DOOR WHEN THERE IS A READILY VISIBLE, I DURING SIGN ON OR ADJACENT TO THE DOOR STATING'THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS" 6"TALL AND 4"WIDE CONCRETE CURB IN FRONT OF MOP SINK-SEE DETAIL O 8 3 I ' 13 7/A400 FOR ADDITIONAL INFORMATION&FINISH. I I \ 2'_2 / I I iO�^ 6 NOTE:ALL EXISTING STOREFRONT DOORS TO REMAIN UNTIL FINAL DAYS OF CONSTRUCTION TO PRESERVE NEW HABIT I I \ 6"I 4 4 I BURGER STOREFRONT DOORS, G.C.TO STORE NEW HABIT BURGER STOREFRONT DOORS AT OFF SITE LOCATION UNTIL PROVIDE"MAXIMUM OCCUPANCY"SIGNAGE ON GYPSUM BOARD-COORDINATE I I \ ", _ INSTALLATION. 14 FINAL LOCATION IN A CONSPICUOUS LOCATION NEAR THE MAIN EXIT OR EXIT 9 ACCESS-DOORWAY. I 6 •/ I r 5 6-�° 11'-QVa" o °. DOOR#2 NOTE:IF PLAN INDICATES EXISTING DOOR AND FRAME TO REMAIN-FIELD VERIFY DOOR AND FRAME SIZE DIGITAL PREVIEW BOARD-CONNECT POWER AND DATA LEADS IN A MANNER z 2 5 '/- I I 1 AND INSPECT HARDWARE FOR COMPLIANCE WITH EQUIPMENT SPECIFIED-NOTIFY ARCHITECT OF ANY SIGNIFICANT 15 WHICH COMPLIES WITH APPLICABLE CODES. SEE FRAMING DETAILS ON 2/A200 _ I 4 ( I I 1 9 50 VARIATIONS DOOR FRAME FINISH:HOLLOW METAL DOOR FRAMES TO BE PAINTED TO MATCH ADJACENT WALL COLOR i6 NEW CEILING SOFFIT ABOVE-SEE RCP ON SHEET A210 FOR ADD.INFO. 1) RESTROOM DOORS:PAINT EXTERIOR(HALLWAY)SIDE OF FRAME TO MATCH ADJACENTWALL COLOR- Sim I / \ I .• RETURN WALL PAINT COLOR TO RESTROOM SIDE OF FRAME STOP-PAINT INTERIOR SIDE OF FRAME P1 19 44), I I •'. - - 1 - --= 4-0 ' 2) OFFICE DOOR:AND FRAME PAINT AS NOTED 17 LOCATION OF NEW ELECTRICAL PANELS.REFER TO ELECTRICAL SHEETS _ l3'0"'- 1-8 ° 3) EXTERIOR SERVICE DOOR:PAINT EXTERIOR SIDE OF DOOR AND FRAME TO MATCH ADJACENT BUILDING COLOR �^ ^ I 6 1' 10 __ ________ I RETURN PAINT COLOR TO EXTERIOR SIDE OF FRAME STOP-PAINT INTERIOR SIDE OF DOOR AND FRAME Pl 18 RECESSED FLOOR SAFE W/KEY PAD(SUPER BRUTE 1500)-REFER TO /. \\ I I� 12 20 00 -- - ' ADJACENT DETAIL 13 A400. - --- -_---_ g 1 TENANT PROVIDE AND INSTALL MULLION MATE WITH SERIES 911 BETWEEN FRAMED WALL r 2 19 AND GLAZING SURFACE MATCH STOREFRONT-INSTALL PER MANUFACTURERS 22 ` 1 ®RECOMMENDATIONS. r--- 2p EXISTING COLUMN TO REMAIN-C.G.TO VERIFY SIZE AND LOCATION. ° I I P1 PROVIDE 4"CONCRETE CURB BENEATH KITCHEN EQUIPMENT. SEE SHEET 1 I I I / FS230 TO CONFIRM CURB DIMENSIONS 19 I / / \ o / I / 2'-0� 4'-0" 4'-0' O DRIVE THRU WINDOW PROVIDED AND INSTALLED BY LANDLORDcli O10'-QY" 19 9'-�" / 4'-9Ya" / ----- ------� W 23 PROVIDE(2)ADDITIONAL LAYERS OF 5/8 GYP.BOARD OVER EXISTING WALL / ° :- FOR"ARTWORK BUMPOUT". // 11 / X 9" 3'-11" 13'-7%" ' L j PROVIDE MOISTURE << 9, 6 / o RESISTANT GYP. / M F- BOARD BEHIND / 400 LJJ F- WALK-IN 4 e/ Il-� Il-IL IL IL-IL 'b co 2X BLOCK AT MOUNTING �, / F J ' Y LJJ 11..1 BRACKET,COORDINATE FREEZER/COOLER i / 16 w/AV INSTALLER 2'-7"t m / a 2 PLYWOOD BACKING •- To Z Z Q — I I 9FA 2 9ffi� II II II II II II II II I ' H U Q' m s 6 ® 1e -o" a SIM. -- — ------- 2' 3" 1 ' CLEAR 5 1 9'-1QTz" 1"zi"BRUSHED COORDINATE ELECT. 518"GYP.BD. BIIIiY OIEIIE 77, ALUMINUM POST wIELECTRICIAN AND REFER TO WALL TYPES 19 AV INSTALLER(i70") .I 16 - COMPOSITE WOOD SCREWED 1l2"PLYWOOD BACKING TO 1'xi"POST PER BEHIND 114'GYP.BD. J ' - MANUFACTURER --- \\\ /n RECOMMENDATIONS,MITER DIGITAL PREVIEW BOARD, I — — — — — I AT CORNERS COORDINATE MOUNTING NOTES: wJ AV INSTALLER/OWNER CPM • GC TO ENSURE COMPOSITE WOOD IS FLUSH W/ 1 1 14 WALL START AND END AS WELL AS CORNERS 1 1 I 18 • GC TO ALLOW FOR EQUAL GAP SPACING ALL AROUND THE DIGITAL DISPLAY(APPROXIMATELY 318') 0 Q • GC TO ENSURE AL COMPOSITE RWOOD ELEVATIONS SLATSATION TO BE VERTICALLY o ALIGNED,COORINATE w/INTERIOR ELEVATIONS(TYP.) 0 O a� TREX SLATWALL DETAIL 3'-11" 18' w -7" i.i' �; O Q SCALE: 11/2°-T m o N p N LL aFLOOR PLAN SCALE: 1/,f-1'-0" �A200 UG II SCHEDULE CEILING PLAN GENERAL NOTES: IIII SYMBOL TYPE DESCRIPTION \X25EDIARCyIri' 1. THE GYP.BD.CEILINGS AT THE FRONT COUNTER AREA,AND IN D2F 4 LED MR16 DOWNLIGHT-FROSTED GLASS LENS WITH HOLE IN THE THE MEWS&WOMEN'S RESTROOM SHALL BE PAINTED WITH A U�;'"CAFILL•"tc" CENTER&WHITE TRIM-VESTIBULE TO RESTROOMS. C� SEMI-GLOSS FINISH. 8=+; LINGLE 4"MR16 ADJUSTABLE DOWNLGHT-RECESSED TRIM WITH WHITE CEILING PLAN KEYED NOTES: Q DIE FINISH-DINING AREA SOFFITS FOR GENERAL ILLUMINATION AT 2. ALL LIGHTS IN THE FRONT SERVICE AND ALL PREP AREAS TO BE AF42319 ENTRY DOORS PROTECTED WITH SHATTERPROOF SHIELDS. BUG LAMP PROVIDED&INSTALLED BY OPERATIONS.G.C.TO PROVIDE OUTLET 4"MR16 ADJUSTABLE DOWNLGHT-RECESSED TRIM WITH WHITE FINIS O GYP.BD.SOFFIT AT 10'-0"t A.F.F.-SEE DETAIL 3&4 ON A220 O -SEE ELEC SHEETS FOR ADD.INFO. /�i�••'• _ O DIN -DINING AREA HARD LID&TECTUM FOR GENERAL ILLUMINATION TRAS 3. PROVIDE HOOD ACCESS ABOVE SCHEDULED CEILING FOR GREASE RECEPTACLES,EXPO,BEVERAGE,&WAITING BENCH 10 4"MR16 ADJUSTABLE DOWNLIGHT-RECESSED TRIM WITH SILVER FINISH DUCT SERVICE. O GYP.BD.CLG.W/BOX BEAM AT 8'-6"A.F.F. -SEE DETAIL 2/A220. GYP.BD.BULKHEAD AT T-0"ABOVE FINISH FLOOR. Q D4F -GENERAL ILLUMINATION AT SERVICE WINDOW ADJACENT TO EXPO AREA 4. ADJUST CEILING GRID LAYOUT AS REQUIRED R POSITION LIGHT 11 STARTING POINT OF CURVE Q D5F 4 MR16 DOWNLIGHT-PULLWAL DOWN ELBOW WITH SILVER FINISH FIXTURES AS DIMENSIONED AND REDUCE NARROW CUT SECTIONS. O SUSPENDED GYP.BD."EYEBROW"SOFFIT/CEILING CLOUD AT 9'-6"A.F.F.- SEE CEILING PLAN GENERAL NOTE#5&DETAIL 2/000 FOR ADD.INFO. NEW KITCHEN EXHAUST HOOD-SUPPORT WITH ALL-TREAD AND UNI-STRUT 4"MR16 DOWNLIGHT-PULL-DOWN ELBOW WITH SILVER FINISH- 5. ALL CURVED SOFFITS TO BE FRAMED WITH FLEX-C-ARCH OR 1p 0 D5S O FROM STRUCTURE ABOVE-SEE MECHANICAL SHEETS FOR ADDITIONAL TO HIGHLIGHT ALL ARTWORK IN DINING ROOM SOFFIT AREAS. APPROVED EQUAL AND SHEATHED W/1/4"HIGH FLEX GYP.BD. 4 GYP.BD.CEILING AT 8'-0"A.F.F.-SEE SHEET A230 FOR FINISH. INFORMATION. ® D7 6"LED 1000 LUMEN DOWNLIGHT WITH WHITE METAL TRIM- AND STAGGERED SEAMS TO CREATE A CONTINUOUS SMOOTH RESTROOMS RADIUS WITHOUT FEAT SPOTS. 13 / OUTLINE OF WINDOW WELL. SEE DETAIL 3 A220 O El 4"MR16 DOWNLGHT-RECESSED TRIM WITH METAL STEPPED 6. NO SUSPENDED LIGHT FIXTURE,DECORATIVE ITEM,OR DISPLAY ITEM O ACT CEILING-SEE PLAN FOR HOT _ w In -AD BAFFLE RATED FOR WET LOCATION-DRIVE-THRU CANOPY AREA MOUNTED ON THE CEILING SHALL BE LOWER THAN 80"ABOVE °'OWALK SURFACES IN ANY CIRCULATION PATH OR WHERE SUBJECT MIN.24"x24"SPACE ABOVE ACT CEILING TO BE CLEAR OF ALL CEILING ITEMS =E2 EXTERIOR DOWNLIGHT RATED FOR WET LOCATION AT TRELLIS TOHUMAN IMPACT. (ELEC,MECH,STRUCT,ETC.)FOR HOOD ACCESS AND GREASE DUCT SERVICE. ❑ -m9 E J In 2x4 LAY-IN TECTUM TILE CEILING AT 11'-6"ABOVE FINISH FLOOR.e E3 EXTERIOR DELIGHT IN PLANTERS/WALKWAYS ❑ ..INSTALL LIGHTS WITHIN SOFFIT IN RANDOM LOCATIONS AS SHOWN J [L C E3-L EXTERIOR IN-GROUND LANDSCAPE LIGHTING;FINISH BLACK F 11'-6'A.F.F. B.O.CEILING 7-2" 4'-0" 11" EPLA EXTERIOR POLE MOUNTED LED SITE LIGHTING FIXTURE IN BLACK; MOUNTING HEIGHT 25FEEf. 2 O" EPLB EXTERIOR POLE MOUNTED LED SITE LIGHTING FIXTURE IN BLACK; r-- T MOUNTING HEIGHT 25FEEf. 4 O . .2'-10y gf"pg • U D 9 2x4 WIRE D GRID TROFFER WITH ADVANCE MARK 10 D3N D3A.F.F. Ki TWO-WIRE DIMMING BALLAST&INTERNAL DISCONNECT SWITCH- KITCHEN/FOOD PREP eJ B.O.CEILING 2x4 2-LAMP GRID TROFFER-WITH ADVANCE MARK 10 - E T K2 TWO-WIRE DIMMING BALLAST&INTERNAL DISCONNECT SWITCH- EM 1400 LUMEN BATTERY-KITCHEN/FOOD PREP 7 1x4 2-LAMP GRID TROFFER-WITH ADVANCE MARK 10 TWO-WIRE D3N 3N 6 2 7 „ o K4 DIMMING BALLAST AND INTERNAL DISCONNECT SWITCH-EM 1400 07 OT LUMEN BATTERY-ELECTRICAL ROOM 4FT 2 LAMP WET LOCATION SURFACE FLUORESCENT-WALK-IN KS FREEZER&COOLER •� 4-3" 5 8„ 4.. 7 DIA.X12 H GLASS OPEN ENDED PENDANT WITH BLACK CORD; - Li FINISH,CRIMSON RED-DINING AREA 3N• "D7 I 7"DIA.X12 GLASS OPEN ENDED PENDANT WITH BLACK CORD; - L2 FINISH,TEAL GLASS-DINING AREA EMI D5E EM2 L3 6"DIA,Xg"HX4.5"CANOPY LED PENDANT WITH RED ACCENT BAND -_-__ _ K1 2 i 6"1` 6 4" W,� I AND COPPER CORD;FINISH,WHITE/TOMATO/COPPER CORD- DINING AREA - - F7 D7 L4 54'W,3-13'BLADE PITCH,6-12 DOWNROD CEILING FAN;FINISH, D4F. 3,-p I O6 D3N p5S BRUSHED POLISHED NICKEL-ENTRY DIN 1 1 K1 K1 N D2f• D2F _ 5 0 3'-1" B L5 525 DIAX4"D BLACK WALL BOOTH MOUNTED LIGHT,FINISH, x HALLWA N BLACK-DINING AREA 'A.F.F.. i i i X �� 8'.6"A.F.F. BATHROOM OVER MIRROR 32'WALL SCONCE WITH SATIN CHROME E.G.CEILING I 1 I L-""' ' B.O.CEILINGIre I W3 FINISH LED 120V.PROVIDED WITH TWO WIRE DIMMABLE LED DRIVER. _ i 1 i r , ,1'-6" -4 0 4 2 8" - 1 2 0 '-1 3 0"' EMi BATHROOM 45"SIDE WALL SCONCE WITH SATIN CHROME FINISH LED - Ira I O W4 120V.PROVIDED WITH TWO WIRE DIMMABLE LED DRIVER. e Ki i 1 = 2'-0" T 4 DUAL MRi6 STRAIGHT SIGNAGE LIGHTING REMOTE DRIVER WITH A 1 8" 7 I x1 x I ®.; N of 3 M2 3 3 D3N I N • D5S L8 "T"MOUNTED AND 24"STEM EXTENSION,FINISH,POWDER COAT I I • K-EXEC XP AREA R GIN x DIN 5S 5S 5 LARGO+LS6 LED MODULE-3,000K,6 LEDS PER MODULE MOUNTED ON THE UNDERSIDE OF THE PASS SHELF ON THE ASSEMBLY SIDE OF THE D4F .' L__ I I -- -------------- D5S YP. K2 i xi x`x -+�: K2 ICI tD4E'. N L3 KITCHEN AREA PROVDE(1)LMPS 350 TRANSFORMER TO POWER UP TO - (SCALED X2) (15)LS6 MODULES.PROVIDE(1)LMPS DIMMER CONTROLLER. :. .. - i ) \ 1 - -_ -------- ------ ----- --- Q 3 D3N (SEE DETAIL#3 LS6 (1)LMPS DIMMER CONTROLLER-FOR USE WITH LS6 FIXTURES ONLY. O - 3 __ __ _ SHEET E410 FOR _ i x i D5F O3 �'}:. D3 - i DEVICE MOUNTING (1)LMPS-350 120V/IOV 35VA OUTPUT TRANSFORMER,(WITH LINE Ul T {LOCATIONS.) CORD). D5F , - i ^ 1 i � T' +3 111"A.F.F3'0 . _ xD4F SOFFIT MINI MR16 120V GU-24 WHITE TRACK HEAD WITH 18"WAND& L3 D3N I] M2S MONOPOINT WITH WHITE HNISH-MOUNTED IN TECTUM CEILING TO p - - _ -__ -__ 3 p HIGHLIGHT ARTWORK&DINING AREA GENERAL ILLUMINATION. 21 i71 SMALL WHITE EMERGENCY BUG EYE 250 LUMEN OUTPUT- D3N F-�. r- D3 = L3 f -- 1 EM1 RESTROOMS,EXPO AREA&SHALLOW HARD LID AREAS IN DINING D4F I F\r _____ 8 1 1 Ki O i `x 4F =33 LARGE WHITE CEILING MOUNTED EMERGENCY FIXTURE 1000 h EM2 LUMEN OUTPUT-HIGH CEILINGS IN DINING AREA ONLY - D3N o J 4"TRACK LIGHTING;MR16 121 TRACK LIGHTING LOW VOLTAGE WITH . . ., I `�<�� = L3 -- T2 BUCK FINISH RATED FOR WET LOCATION-MOUNTED IN TREWS FOR - i 12 �. D3 I o v OUTDOOR DINING AREA. _ ,. _ L3__ L3_ X1 RECESSED SINGLE FACE EDGE-LB EMERGENCY EXIT W/BATTERY BACKUPcli / n _______ _ ,`•,"`'.✓''f ____IK -_ ___ 5S •3N w &GREEN LETTERS ON CLEAR PANEL-FOR USE IN DINNING AREA. �' oL3 Di I n " X1A RECESSED SINGLE FACE EDGE-LB EMERGENCY EXIT W BATTERY BACKUP 1'S ♦ y h ", &GREEN LETTERS ON CLEAR PANEL-FOR USE IN DINNING AREA. 4 • I Lu 10 DIN X2 WHITE EMERGENCY EXIT SIGN WITH GREEN LETTERS-BOH. D4F _ 9'6"AFF - M ~ WHITE DIRECTIONAL EMERGENCY EXIT SIGN WITH GREEN LETTERS- B.O.CEILING ; B.O.SOFFIT h4 1 11'-0"A.F.F W X2A BON. 3'-5" ' ....;/ W 1,_O EXTERIOR WET LOCATION EMERGENCY LIGHT IN DARK BRONZE . "' ° iPi -{i( �i ii m Q O Cn 0 X3 FINISH.FOR USE OVER EXTERIOR EGRESS DOORS -- ..'/ D3Namli n u n 3 3N J — • D5S LVi 1LIH Lill Liii 1H � !, II04 u u n u - o _ � u u u n n u 4'-9" 5 1'-5" n u u u u u Z NOTE:ALL EXIT AND EMERGENCY LIGHTING FIXTURES SHALL BE EQUIPPED WITH EMERGENCY -'� - i -_ ❑ I BATTERY BACKUP AND COMPLY WITH ALL LOCAL AND NATIONAL CODES. -10 NOTE:SEE ELECTRICAL PLANS(E2001&ELEC SCHEDULE(E210)FOR ADD.INFO. K )DIN *CONTRACTOR TO VERIFY BACK OF HOUSE EXIT LIGHT FINISH WITH LIGHTING VENDOR. 10 'J .�'y, ® ]i L� .D5F w� K2 I EM2 D5S 4�lNl 3' 0" 3' 1" 2'-1'—2' 11 3' 1" i USF O R10'_I" (7)FIXTURES® 1,J. = /. ', •i - O ' .. ` x:.. 'D5F C• iB'-0'ViF.FI 2 3N 3(J .O.�OF T N 4, O„ N 4' O„ N 4' O„ N 4,10„ N 4,_0„ D33._O. I B.O.CEILING Q D3 D3 D3 D3 D3 O.' . s, DS `vS -� 5S EM2 55 13 1 13 ® 13 D5S I - E 3N 11 DSSe O D3N D3N I 0 �. I J =i Lj �t D3N _�,. - Xi A400 �m s, 2 0 2'-10Y" 4'-0Y" W A400 T-0" 6'-0" 6'-0" 7" 6'-3" 6'-6" 2 2 4'-0" 3'-3' 1'-3' 1'-9' +1-13'-9'A.F.F. B.O.SOFFIT PA710 .G.8 A.F.F. L -- o U B.O.SOFFIT i Lu J o N LL aENLARGED SOFFIT PLAN w N 2 =1' 1 REFLECTED CEILING PLAN SCALE 1/2' -0' N SCALE: 1/4'=1'-0- A210 IGHTING SCHEDULE CEILING COORDINATION PLAN GENERAL NOTES: O D2F 4 LED MRi6 DOWNLIGHT-FROSTED GLASS LENS WITH HOLE IN THE "YTp9II111fIp/X CENTER&WHITE TRIM-VESTIBULE TO RESTROOMS. ATTACH TO EXISTING STRUCTURE OR DECK 1. FOR LIGHTING LOCATIONS AND CEILING HEIGHTS AND FINISHES SEE 9E�.ARC"I��pi 4"MR16 ADJUSTABLE DOWNLIGHT-RECESSED TRIM WITH WHITE NOTE: REFER TO SHEET A3O0 FOR ATTACHMENT ABOVE - GC SHALL VERIFY CORRECT Q D3F FINISH-DINING AREA SOFFITS FOR GENERAL ILLUMINATION AT DETAILS AND NOTES AT EXISTING STRUCTURE FASTENERS FOR EXISTING STRUCTURAL REFLECTED CEILING PUN ON SHEET A210. U: CABLE. ENTRY DOORS BRACE DIAGONALLY TO STRUCTURE ABOVE TYP COMPONENT MATERIALS _ 4'MR16 ADJUSTABLE DOWNLGHT-RECESSED TRIM WITH WHITE FINIS 2. PROVIDE HOOD ACCESS ABOVE SCHEDULED CEILING FOR GREASE DUCT ==+: LINGLE •�+= O D3N -DINING AREA HARD LID&TECTUM FOR GENERAL ILLUMINATION TRAS BOTT. OF PROVIDE MIN. (3) #1Ox1/2" SERVICE. -2319 RECEPTACLES,EXPO,BEVERAGE,&WAITING BENCH hSTRUCTURE SELF-DRILLING TEK SCREWS V EL. VARIES AT EACH DIAGONAL BRACE 3. G.C.TO REFER TO LIGHTING AIMING GUIDE IN SPEC BOOK TO NM ALL / ••• _ 4"MR16 ADJUSTABLE DOWNLIGHT-RECESSED TRIM WITH SILVER FINISH i Q D4F CONNECTION ARTWORK LIGHTING CORRECTLY. -GENERAL ILLUMINATION AT SERVICE WINDOW ADJACENT TO EXPO AREA I Q D5F 4 MR16 DOWNLGHT-PULL-DOWN ELBOW WITH SILVER FINISH 3 5/8" 20 GA. MTL STUDS -MENU AR TILEWA 0 48" O.C. MAX FOR Q D5S TO R16 DHW UG ARTWORK PULL-DOWNIDINING LBOW WITH SILVTF ER FINISH- LATERAL BRACING 6"LED 1000 LUMEN DOWNLIGHT WITH WHITE METAL TRIM- 3-5/8" 2OGA MTL. STUDS CEILING PLAN KEYED NOTES: ® D7 RESTROOMS TECTUM TILE AT 16" O.C.- TYP. 0 E1 4"MR16 DOWNLIGHT-RECESSED TRIM WITH METAL STEPPED TECTUM CEILING B.O. SOFFIT & T.O. STOREFRONTO MIN.24"X24"SPACE ABOVE ACT CEILING TO BE CLEAR OF ALL CEILING BAFFLE RATED FOR WET LOCATION-DRIVE-THRU CANOPY AREA hCEI LING VARIES O ITEMS(ELEC,MECH,STRUCT,ETC.)FOR HOOD ACCESS AND GREASE DUCT ww- --�0 '-� EXISTING STOREFRONT SERVICE.E2 EXTERIOR DOWNLIGHT RATED FOR WET LOCATION AT TRELLIS P2 P2 SYSTEM, WHERE OCCURS - AD CORNER BEAD NP O SHROUD WALL ABOVE SOFFIT-SEE DETAIL 2/A400 FOR ADDITIONALSEE PLAN FOR SOFFIT E3 EXTERIOR UPLIGHT IN PLANTERS/WALKWAYS LOCATIONS INFORMATION. HALLWAY BOX BEAM-SEE DETAL 2/A221B.OFFIT 10' 0 PROVIDE MIN. (2) #1Ox1/2"P2 SELF-DRILLING TEK SCREWS .. 5/8" GYP BD.- SEE FINISH AT EACH STUD TO TRACK O OUTLINE OF WINDOW WELL. SEE DETAIL 3/A220 3 w Li PLAN FOR PAINT TYPE SEE CEILING PLAN A210 CONNECTION J e E3-L EXTERIOR IN-GROUND LANDSCAPE LIGHTING;FINISH BLACK ( ) 1-4 EXIT LIGHT FIXTURE - SEE E2OO F I EpLA EXTERIOR POLE MOUNTED LED SITE LIGHTING FIXTURE IN BLACK; MOUNTING HEIGHT 25FEEL EPLB EXTERIOR POLE MOUNTED LED SITE LIGHTING FIXTURE IN BLACK; __ I MOUNTING HEIGHT 25FEET. a TYPICAL SOFFIT AT STOREFRONT DETAIL 2x4 2-LAMP GRID TROFFER-WITH ADVANCE MARK 10 SCALE: 1/2'-1'-0" O N `T 67 D K TWO WIRE DIMMING BALLAST&INTERNAL DISCONNECT SWITCH- D3N KITCHEN/FOOD PREP Q 2x4 2-LAMP GRID TROFFER WITH ADVANCE MARK 10 F—H I OO- NOTE. REFER TO SHEET A3O0 FOR ATTACHMENT LAIK2 TWO-WIRE DIMMING BALLAST&INTERNAL DISCONNECT SWITCH- ATTACH TO EXISTING STRUCTURE OR DECK ABOVE DETAILS AND NOTES AT EXISTING STRUCTURE W3 EM 1400 LUMEN BATTERY-KITCHEN/FOOD PREP - GC SHALL VERIFY CORRECT FASTENERS FOR I BRACE DIAGONALLY TO STRUCTURE ABOVE TYP EXISTING STRUCTURAL COMPONENT MATERIALS lx4DIM IN LAMP GRID TROFFER-WITH ADVANCE MARK 10 TWO-WIRE' 3N W� K4 DIMMING BALLAST AND INTERNAL DISCONNECT SWITCH-EM 1400 BOTT. OF Q D7 D7 LUMEN BATTERY-ELECTRICAL ROOM hSTRUCTURE � K2 ® D7 AFT 2 LAMP WET LOCATION SURFACE FLUORESCENT-WALK-IN ELEL. Vq�RIES ® 0 K5 FREEZER&COOLER T DIA X12"H GLASS OPEN ENDED PENDANT WITH BLACK CORD; 3-5/8" 2OGA MTL Li FINISH,CRIMSON RED-DINING AREA STUDS AT 16' OC TYP. 3N L2 7"DIA.X12 GLASS OPEN ENDED PENDANT WITH BLACK CORD; L—J Q 1A D7 ; FINISH,TEAL GLASS-DINING AREA 3 5/8" 20 GA. MTL EMS 6"DIA X9"HX4.5"CANOPY LED PENDANT WITH RED ACCENT BAND STUDS @ 48" O.C. MAX Ki L3 TECTUM TILE FOR LATERAL BRACING EMi W AND COPPER CORD FINISH,WHITE/TOMATO/COPPER CORD- TECTUM CEILING ' DINING AREA hCEILING PROVIDE MIN. (2) #1Ox1/2" D3N IS D7 D7 L4 54W 3 13'BLADE PITCH,6-12 DOWNROD CEILING FAN;FINISH, q CEILIN SELF-DRILLING TEK SCREWS I DSS 0, BRUSHED POLISHED NICKEL-ENTRY AT EACH STUD TO TRACK O Q P2 CONNECTION I K1 K1 D3N :2F - :2F 5.25"DIA.X4"D BLACK WALL BOOTH MOUNTED LIGHT,FINISH; x - 0 L5 hB.O. SOFFIT BLACK-DINING AREA '��EWL ( 3 1 O'_p" EXISTING WALL, WHERE OCCURS- I I I I 0 W3 BATHROO RO,M OVER MIRROR 32"WALL SCONCE WITH SATIN CHROME P2 SEE PLAN FOR SOFFIT LOCATIONS I �� i i i i I ) D3N EMi WTHFINI DRIVER, CORNER BEAD TYP I I I I r l SEE CEILING PLAN A210 I I I I i I J'V_cljl� DSFBATHROOM 45'SIDE WALL SCONCE WITH SATIN CHROME FINISH LED ( )W4 5/8" GYP BD. III120V PROVIDED WITH TWO WIRE DIMMABLE LED DRIVER Ki xI I I i `D4F � I DUAL MR16 STRAIGHT SIGNAGE LIGHTING REMOTE DRIVER WITH A I vvI> I li I Q D3Nq, 8" D31 EM2 D31 D31 �.P N L8 1.MOUNTED AND 24"STEM EXTENSION,FINISH POWDER COAT I I ixxi �' I D5S •(�J. BLACK EXPO AREA SOFFIT ADJACENT TO STOREFRONT DETAIL I I I;;I I ' ° -.1 LARGO+LS6 LED MODULE-3,OOOK,6 LEES PER MODULE-MOUNTED ON (]4 � I I I a I I - D3N .J SS SS 5S _ THE UNDERSIDE OF THE PASS SHELF ON THE ASSEMBLY SIDE OF THE SCALE: 1/2'=1'-0" L__ I f I ' _ _-- _-- -- 1 KITCHEN AREA PROVIDE(1)LMPS 350 TRANSFORMER TO POWER UP TO I K2 I I/y�, I K2 'p4F D3N I (SCALED X2) (15)LS6 MODULES PROVIDE(1)NAPS DIMMER CONTROLLER I x` I Q �3_ D3,N I I * __ _ ___ • • (SEE DETAIL FOR LS6 (1)LMPS DIMMER CONTROLLER-FOR USE WITH LS6 FIXTURES ONLY. i i x\ i ' ( 2 3 3 O `O SHEET E410MOO FOR I f xx I �'� -- _- --- DEVICE MOUNTING (1)LMPS-350 120V/10V 35VA OUTPUT TRANSFORMER,(WITH LINE I x` I DSF I cd 31 �--- LOCATIONS.) CORD). i i ��i K1 - D3N L3-- __ L3 /,1D4F �,. ,1. MINI MR16 12DV GU-24 WHITE TRACK HEAD WITH 18"WAND& Ix `xl O D3 p M2S MONOPOINT WITH WHITE FINISH-MOUNTED IN TECTUM CEILING TO ❑ ( L3 __ _ �Q HIGHLIGHT ARTWORK&DINING AREA GENERAL ILLUMINATION. SMALL WHITE EMERGENCY BUG EYE-250 LUMEN OUTPUT- (_ < 3 `-- �L3 _ �j' EM1 RESTROOMS,EXPO AREA&SHALLOW HARD LID AREAS IN DINING LARGE r �} K1 K1 I`.� I �4F 3N L3 `YL3 EM2 LUMEN OUTPUT HIGH OCEILINGS UNTED IINRDINING AREA GENCY FIXTURE 1000 • � 3 Y'L3 �43 C 4"TRACK LIGHTING;MR16 12V TRACK LIGHTING LOW VOLTAGE WRH `� --------- I ���� I �' � --- T2 BUCK FINISH RATED FOR WET LOCATION-MOUNTED IN TREWS FOR i i 3 * + I J OUTDOOR DINING AREA. I I L3 _ L3_ Xi RECESSED SINGLE FACE EDGE-LIT EMERGENCY EXIT%ATTERY BACKUP K IIt &GREEN LETTERS ON CLEAR PANEL-FOR USE IN 61NNING AREA. SF / D3 D5S r"r X1A RECESSED SINGLE FACE EDGE-LIT EMERGENCY EXIT W/BATTERY BACKUP E / Q ® lJ I LLI &GREEN LETTERS ON CLEAR PANEL-FOR USE IN DINNING AREA. 3'-11" `4'-1 ` I w F CIO 2) X2 WHITE EMERGENCY EXIT SIGN WITH GREEN LETTERS-BOH. 41' 4 w X2A WHITE DIRECTIONAL EMERGENCY EXIT SIGN WITH GREEN LETTERS- K1 K2 0`'� �/ 2 „ „ I 20 rn o BOH. / / u u li a II II n DSS I W H M ~ 0p3N o L➢u 1ii 1il�i �u ii ii ii O3 DSO Q,ZN ; m m W p /W� EXTERIOR WET LOCATION EMERGENCY LIGHT IN DARK BRONZE i j ° II II X3 FINISH.FOR USE OVER EXTERIOR EGRESS DOORS J O O Cn 9 111 111 1 O II I J NOTE:ALL EXIT AND EMERGENCY LIGHTING FIXTURES SHALL BE EQUIPPED WITH EMERGENCY BATTERY BACKUP AND COMPLY WITH ALL LOCAL AND NATIONAL CODES. I IL ii ii ii I w} Z J NOTE:SEE ELECTRICAL PLANS,SHEET E200 FOR MORE INFORMATION. K2 u u II li a — D3N a II II ii ii ii n p3 '-" ; U rn m II II II II II II II II . *CONTRACTOR TO VERIFY BACK OF HOUSE EXIT LIGHT FINISH WITH LIGHTING VENDOR. I � Q u u II II a II II n Q ' K2 I EM2 'D5$ D3N. ___ __ I .�.. ATTACH TO EXISTING STRUCTURE OR DECK ABOVE - GC SHALL - VERIFY CORRECT FASTENERS FOR {�. O O :3N :3N 3N :3N :3N :3N EXISTING STRUCTURAL COMPONENT 'Tf.2., 3N 3N 4 4 4 I Z MATERIALS 3 ; TECTUM TILE CEILING 20 - `='D5S EM2 5S _ J h HIGH PANEL CEILING SEE SCHED. HT. ON RCP 4 3 5 8" 2OGA MTL DSSe D)N D3N. I 0 STUDS AT 16" OC TYP. SL2 ,L2 :'Q Q / 0D5.' H 5/8" GYP BD.- SEE FINISH ' .D3N Xi I z :. PLAN FOR PAINT TYPE o k CORNER BEAD TYP p3 6"x6" MTL STUD BOX BEAM 6" z2O 20 20 O W/FINISH FACE AT 8" m m IL o B.O. SOFFIT HALLWAY CEO. 5.. 1'-7° 27, 6- w SEE SCHED. HT. ON RCP ------------------------------------ m U 14F C-9 ( PROVIDE MIN. 2 10x1 2" P3 N SELF-DRI LUNG TER SCREWS AT L o O EACH STUD TO TRACK CONNECTION °' o 04 0 w BOX BEAM * HALL DETAIL I al CEILING COORDINATION PLAN SCALE: 1/2'-T-0' aj �A220 SCALES 1/4°=1'-0° NOTE:WHERE SUBWAY TILE IS MARLITE FRO PANELS WHERE THEY PRESENT-SUBWAY TILE TO OCCUR-INSTALL TO 5"A.F.F. START ABOVE TILE BASE TO 5/8"DUROCK CEMENTIOUS CREATE INTEGRAL COVE BOARD TO 12"A.F.F.(ttP AT FINISH PLAN KEYED NOTES: ,§Nx o_0IARCy; ALL TILE BASES) PRE-MANUFACTURED COOLER/ �(�.+° FREEZER WALL S 0 CAPLL°:Fn CLEAR SILICON SEALANT CONT. ALL BACK OF HOUSE AREAS TO HAVE 2"x2"STAINLESS STEEL CORNER GUARDS g:Ir LINGLE ABOVE TILE BASE O OVER FRP AT OUTSIDE CORNERS FROM TOP OF EPDXY BASE TO CEILING. FT-2, TILE PER PLAN TILE BASE AS SCHEDULED 1/4"CEMENTIOUS BOARD w/ PROVIDED AND INSTALLED BY F.S.E.C. AA-2319 45'CHAMFER SCHLUETER-DECO FLOOR TILE AS SCHEDULED O SS WALL CAP TO BE FULL HEIGHT OF SCHEDULED PARTITION-F.S.E.C. ... •'° _ WATER-PROOF MEMBRANE(LATICRETE 3 FABRICATE CLOSURE PANEL BETWEEN WALL FINISH AND COOLER/FREEZER FT-1, TILE PER PLAN - #9235 OR APPOVED EQUAL)12"ON EPDXY FLOOR w/INTEGRATED O FLOOR AND WALL IF SLOPE PRESENT P COVE BASE AS SCHEDULED PANEL SURFACE-SEAL OPENING FULL HEIGHT GROUT N MAN. ® WATER HEATER ON 5 1/2"TALL GONG PAD WITH EPDXY FLOORING TO RUN CONCRETE SLAB ^ 1_9116" UP AND OVER PAD CONTINUOUS WITH FOOD PREP FLOOR-SEE 8/A400. NP-1 CAULK BETWEEN DUR-ROCK ^�_0 MIN SLOPE a O TILE/EPDXY TRANSITION STRIP-SEE DETAIL 5/A230 FOR ADD.INFO. - AND CONCRETE TILE BASE al EPDXY BASE AT COOLER © TILE/TILE TRANSITION STRIP-SEE DETAIL 4/A230 FOR ADD.INFO. _ a SCALE: 1 1/2.4-0- 7 EPF1 TO BE RAN UP ALL THREE SIDES OF MOP SINK UP TO BOTTOM OF ~p v SCALE: 1 1/2°=T-�° O PLATFORM-SEE DETAIL 7/A400 FOR ADDITIONAL INFORMATION. -0 m o a�LE / TILE TRANSITION NOTE:WHERE SUBWAY TILE IS REFER TO PLAN FOR FINISH N PRESENT-SUBWAY TILE TO g FORMED CONCRETE PLATFORM FOR CASEWORK OR EQUIPMENT-SEE SHEET START ABOVE BASE TO CREATE A200 FOR ADDITIONAL INFORMATION. i J SCALE 6°=1'—O° EXTERIOR DOOR & STOREFRONT START COVE 5/8"DUROCK CEMENTIOUS J 3 w i.. BOARD TO 12"A.F.F.(lYP AT O KITCHEN VENDOR TO WRAP COLUMN WITH STAINLESS STEEL o ALL TILE BASES) J ul a MTL2-BRUSHED STAINLESS STEEL 4 z SCHLUTER SCHIENE PROFILE OR BRUSHED o ALIGN TILE W/THRESHOLD BLACK ALUMN.APPROVED EQUAL EPDXY FLOORING w m 3/8"FORMED EPDXY COVE BASE MTL2 - BRUSHED STAINLESS STEEL EPDXY FLOOR AS SCHEDULED SCHLUTER SCHIENE PROFILE OR BRUSHED WATER-PROOF MEMBRANE(UATICRETE BLACK ALUMNI. APPROVED EQUAL #9235 OR APPOVED EQUAL)12"ON < c a GROUT FLOOR TILE/GROUT REF FLOOR FLOOR AND WALL IF SLOPE PRESENT PATTERN PLAN FOR LAYOUT CONCRETE SLAB ON GRADE NP-1 CAULK FRP P3 WC1 FTB1 CT2 FTB1 ° a BETWEEN DUR-ROCK (2'-0"MIN SLOPE) FT1 THRESHOLD SEE HARDWARE SCHEDULE AND CONCRETE n 4 MAXIMUM CHANGE IN LEVEL SHALL BE 1/2" EP1 -- EXTERIOR EXPANSION JOINT FOR REFERENCE ONLY EPDXY BASE NO FINISH BEHIND LL EP1 ''�` FT1 I(9 �0 SCHEDULED TILE '.FREEZER OR rr EXIST. CONC. SLAB SCALE: 11/2°=T-0' COOLER TAPE& 7 PZ TILE / EPDXY TRANSITION I THRESHOLD a ENTRANCE DOOR PRIME GYP BD & 2 �; QTZ FTa, DUROCK a a o , p2 SCALES 6°-1'-0' SCALE 3'-1'-0' wc1 I FTB1 FINISH PLAN GENERAL NOTES: FINISH MATERAL SCHEDULE EPDXY NOTE: ® 1 AY OEM"I- THE FINISH WILL BE SMOOTH BELOW EQUIPMENT&SLIP P3 ITEM) DESCRIPTION MANUFACTURE IDENTIFICATION COLOR NOTES ROOMS RESISTANT IN WALKWAYS WITH FLOOR DRAINS PROVIDED TO WASH DOWN THE FLOORS.EPDXY TO BE APPLIED OVER THE FTB1 FTI 5/8"DUROCK AT BOTTOM OF WALLS AND HAVE A 3/8" 1 - --- �LL '' COVED BASE THAT EXTENDS 6"UP THE WALL. AT OUTSIDE - I ACOUSTICAL CEILING TILE® USG CLEAN ROOM CLIMA PLUS WHITE WASHABLE FLAME SPREAD CLASS 100 WITH FIRE CODE-NON-COMBUSTIBLE OF FREEZER/COOLER PANELS AND THE INSIDE Of COOLER ACT BACK OF HOUSE / 103 #3270 STIPPLE(2'X4'Xh") PANELS 6"TALL STRIPS OF 1/4"DUROCK ARE ADHERED TO FRP 2 CT2 P2 P3 BOTTOM OF PANELS WITH CONSTRUCTION ADHESIVE AND SST WC1 FT1 WC1 ACT2 TECTUM CEILING IN MAIN TECTUM INC. DIRECT ATTACHED CEILING WHITE WASHABLE FLAME SPREAD/CUSS 100 WITH FIRE CODE-NON-COMBUSTIBLE 101 SELF TAPING SCREWS ALTERNATING HIGH AND LOW FRP FTB1 FTB1 DINING AREA PANELS(48"X96") PLACEMENT AT 8"ON CENTER.EPDXY COVED BASE TO BE SST rr POURED OVER DUROCK STRIPS AT FREEZER/COOLER CT2 FT2 PAINT PANELS.NO EPDXY FLOORING IN FREEZER NEEDED WITH CT2 P1 PAINT DUNN EDWARDS DEC793 CHALKY EGGSHELL&SUITABLE FOR EXTERIOR USE WHERE NEEDED 101,103 METAL FLOORING SYSTEM PROVIDED BY MANUFACTURE. EP1 P4 WC1 FTB1 COVE BASE NOTE: EP1 6 INCH ; P2 PAINT DUNN EDWARDS DET423 RED CRAFT EGGSHELL&SUITABLE FOR EXTERIOR USE WHERE NEEDED 3/8"INTEGRAL COVED BASE THAT EXTENDS A MINIMUM OF ® FTB1 i 4"UP THE WALL IS PROVIDED IN THE CUSTOMER COUNTER EP1 WC1 FTB1 P3 PAINT DUNN EDWARDS DET469 WESTERN SUNRISE EGGSHELL 100,101,106 AREA(SELF-SERVICE BEVERAGE COUNTER)AND IN THE 2 KITCHEN I -------------------------- I RESTROOMS.THIS INCLUDES ALL REQUIRED FLOOR/WALL 102 PAINT DUNN EDWARDS DE6383 BANK VAULT EGGSHELL 100,101,106 JUNCTURE,FLOOR/COUNTER TOE KICK JUNCTURE, i LL N __ --__ _ ---- ------_ P4 FLOOR/MOP SINK JUNCTURE OF ANY LOW WALL MOUNTED i B PAINT DUNN EDWARDS DEA188 BLACK BAY EGGSHELL MOP SINK,FLOOR/ELEVATED FLOOR SINK JUNCTURE AND i BULKHEAD O WC PS CONTINUOUS COVED BASES.ALL OUTSIDE TILE CORNERS SST SST BULKHEADS " ABOVE FTB1 WALLS WILL HAVE MITERED EDGES. SST ABOVE I I 9 FT1 --_ _ ----- ; COUNTERTOP LAMINATE NOTE: FT2 WALL COVERING MDC WRICGYERING DEW CGLLEC110N CALVIN REVERSIBLE HALF DROP MATHCH-(REPEAT 26.38V;19.6"H) 100,101,106 COUNTER TOPS ARE FINISHED WITH FORMICA PUASITIC EP1 I i ______ FT7 _____ _ __ WC1 TULLE-E;ANM-4416 CDNLICF.En*WonW Eli Wd9mQC&c*m 1AM252-MM LAMINATE 9011-NT ZEBRANO NATURELLE UNLESS NOTED \ L------1 WC1 WC1 P3 MAIN COUNTER COVERINGS ETC: ERO-TERR MISTY GREY SIZE:SLAB;MILLWORK CONTRACTOR N A OTHERWISE. INTERIOR SURFACED TO BE FINISHED WITH �-(`1 I ADJACENT CS1 / SAME OR WHITE PLASTIC LAMINATE WITH NO EXPOSED ssT 2 I z -- _--FTB1 FTa1_-- _ ___-- WC1 I CORPORATE \ I Fret ; TENANT J BAREWOOD ALLOWED IN CABINETS,SHELVING OR UNDERSIDE `--�}� CHAIR RAIL&WALL CAP SOLID SURFACE ONE QUARTZ SURFACE CHIPPED ICE NQ91 MILLWORK CONTRACTOR OF COUNTERS. �"' I _ ------ ----- - --- CS2 CONTACL Tamara G.tmTaFagTnndlekyOdaMie.can i WC1 I o ACCENT TILE 0 MAIN DINING FIRE CLAY TILE GLASS-POUSHED PLANKTON V3 GROUT:h"CUSTOM BUILDING PRODUCTS-SNOW WHITE#11;(SIZE 2X4) 101,103.107 3M MILKY FILM NOTE: SST S __ ____ ___ - _____ FTB1 MAXIMUM WIDTH OF FILM IS 36".TOP OF FILM TO ALIGN SST I I � CT1 /KITCHEN CONTACT:Tamara G.tamaro.gmnduekyOddMe.com .108 WITH TOP OF LOWEST TABLE TOP HEIGHT OR ON ENTIRE SST ,, I Wcli FEATURE/BATHROOM WALLS LOWER PANEL ONLY IF PANEL IS LESS THAN LOWEST TABLE �,, ' --- - -- ---.-._ I LV BLOCK TILES FOR KITCHEN/ DALTILE DB ELEVARE EL40 LUNAR GROUT:y"CUSTOM BUILDING PRODUCTS-BRIGHT WHITE#381;(SIZE 016) 101,103.107 TOP HEIGHT.SEE INTERIOR ELEVATIONS ON A500 FOR 3 - F CT2 DINING AREA&RESTROOM WHERE NOTED ON PLANS&ELEVATIONS .108 ADDITIONAL INFORMATION. FTB1 WALLS CONTACT:TAMARA G.TAMARA. NO EPDXY �, TILE NOTE: FLOORING UNDER i 101 I U M EXTERIOR TILES DALTILE CONSULATE FONG CS0512241T TEX PREMIER GREY CDNTACk TAMARA G TAMWAGRNIMUSKYODALTRECOM ALL TILED AREAS WHERE WATER WILL BE PRESENT FREEZER BULKHEAD pgp �'� OB I LU T- CT3 (RESTROOM SERVING,ETC...)SHALL COMPLY WITH SECTION NO FINISH BEHIND EP1 .ABOVE -- I W co LJJ 12j co 10.2&1210.3 OF 2012 IBC.TILE WILL BE APPLIED FREEZER OR CT Y MOSAIC GLASS TILE DALTILE CITY LIGHTS CAPRI CL68 MENS TOILET ROOM ACCENT TILES-INSTALL FLUSH W/SUBWAY TILE, 107 COOLER TAPE& 2 I m CT4 OVER MR.GYP.BD.&DUROCK&HAVE A COVED BASE ,� FT2 Q O Cn PROVIDE BACKING AS REQUIRED THAT EXTENDS A MIN OF 4"UP THE WALL.SEE INTERIOR PRIME GYP.BD. CTS MOSAIC GLASS TILE DALTILE CITY LIGHTS ST.THOMAS CL70 WOMENS TOILET ROOM ACCENT TILES-INSTALL FLUSH W/SUBWAY TILE, 108 ELEVATIONS,PARTITION TYPES&RESTROOM PLAN GENERAL DUROCK `� \ WC1 I =Z Q PROVIDE BACKING AS REQUIRED NOTES FOR ADDITIONAL INFORMATION.ALL OUTSIDE CORNERS 3 FRP FTB1 I J WOOD-MAIN DINING WOOD TREX TRANSEND COMPOSITE DECKING TIKI TORCH SIZE PER DRAWINGS,FINISH TO BE SUBMITTED FOR APPROVAL 101 TO HAVE MITERED EDGES. 6 I W z 11'3 Z WD1 SLATS Fri woe WOOD-EXTERIOR SLIDING AS - DOUGLAS FIR 2 COATS MATTE SEALER SIZE PER DRAWINGS,FINISH TO BE SUBMITTED FOR APPROVAL EXTERIOR FRP FRP NOTED ON ELEVATIONS WOOD-BAMBOO WAINSCOTING PLYB00 STILLETTO FL-P5872WS/CL-NAUF/FS SIZE PER DRAWINGS,FINISH TO BE SUBMITTED FOR APPROVAL EP1 EP1 u WD3 WHERE NOTED C CDNTACT:Dalise Ulm da118**baocan 1.41UM6701 ® P2 z err--7r--7r--7r--rr--7r--7r-- WS1 STAIN - - - LIGHT STAIN TO MATCH TABLE TOPS,SAMPLES TO BE APPROVED f P3 BY MILLWORK CONTRACTOR FRP ig PILL PLASTIC LAMINATE-RESTROOM NEVAMAR - DRY GREEK PLUM TREE - 107,108 - WC1 DOORS WZ6001T TEXTURED FTa1 P3 WC1 FTB1 I - FRP1 FIBER REINFORCED WALL MARLITE STANDARD FRP P(100)WHITE COLOR OF MOLDING WILL MATCH PANEL.ADHESIVELY APPLY PANELS OVER - PANELS SOUD SUBSTRATE IN ACCORDANCE TO ALL MFG INSTRUCTIONS FLOORS WC1 SUNBELT EPDXY SUNBELT 1100 EXPDXY FLOORING WHERE NOTED ON PLANS 102,103,104 FTB1 - pp EP1 EPDXY FLOORING FLOORING TRUE GREY '105, FT1 COOLER WC1 WC1 WC1 PAN AMERICA TIME 2.0-P36C9(6X12 COVE 102,103,104 P3 FTB1 FTB1 FTB1 FUEL COVE BASE CERAMICS-FLORIDA TILE BASE) 125131 DOVE WITAC.Erin Dabey ednOpanamericanceramice 1.626.961.0051 105, WC1 WD1 COOLER FTB1 P2 WC1 FTB1 P4 WC1 FTB1 MAIN DINING FLOORING PAN AMERICA CERAMICS NATURE HOP 28013 NANTUCKET GREY GROUT:J"CUSTOM B.. DING PRODUCTS-WINTER GREY#335;(SIZE 6X4) 100,101 I Z FT1 -FLORIDA TILE CDMACT:ERN)DALLIEY ERINOPANALIEPoPNICFRAYCS 1.826.981.0051 J FT2 ACCENT FLOORING/ DALTILE NATURA CUSTOM-OH63 PEEL GROUT:M"CUSTOM BUILDING PRODUCTS-WINTER GREY#335;(SIZE SXS) COUNTER WHITE GG TO APPLY HEAVY DUTY c"M1TIE SEALER _ O GT/TRIM 0 (V N ROU N rn FINISH PLAN LLZ a SCALES 1/4°4-0' A2 3 0 25E 11IAII q,O ••arc E U: CARLL•:6`C o AR-2319 e GRAPHICS PLAN GENERAL NOTE: - G.C.TO REFER TO LIGHTING AIMING GUIDE IN SPEC BOOK TO AIM ALL ARTWORK LIGHTING CORRECTLY. /��pL�p�y�y�� ------------- - --------------- .---------------- GRA 1 IM�SCHED U PROVIDED BY OWNER-GC TO NSTALL UN.O.-NOT ALL GRAPHICS ARE USED. LIEN f 71RE FAME Oi MENU BOARD 99,25"x 37,25" 2"STAINLESS STEEL I ui OTHERE'S NO SUBSTITUTE FOR QUALITY SEE SHOP DWGS NONE i (BYSIGNAGE CONTRACTOR) o I z m m OESTABLISHED 1969 IN SANTA BARBARA BELT BUCKLE SEE SHOP DWGS NONE a 1 3 in (BY SIGNAGE CONTRACTOR) 1 ORDER PICK-UP SEE SHOP DWGS NONE F- 1 (�0 3 w J OO (BY SIGNAGE CONTRACTOR) ~------ phOS DIGITAL DISPLAY BOARD SEE SHOP DWGS NONE MEN o e 1 O STORYBOARD 36"x 48" 3/4"SHADOWBOX WOOD - 74, f 4 OCUSTOM BUILT SEE SHOP DWGS NONE - 500 (BY SIGNAGE CONTRACTOR) JII 1 O LIFEGUARD TOWER 54"x 36" 4"SQUARE WOOD e 1 FOOD SANTA BARBARA STREEI SIGN 54"x 36" 4"SQUARE WOOD -,- W�J 1 ALONG THE NATER 1 11 CABRILLO 54"x 36" 4"SQUARE WOOD _ '�ii �ii"�ii l 24'x 0 1 13 1 12 SANTA BARBARA HARBOR SCENE 54"x 36" 4"SQUARE WOOD } 1 13 ALONG THE WATER 24"X 36" 4"SQUARE WOOD 14 SOUTHERN COASTLINE 60"x 25" 4"SQUARE WOOD �' _T-L �jpp ] � 18 12 1 RED SURFBOARD 36"X 36" 4"SQUARE WOOD ----+_I `�-- IN 196G 00 CABALLO AVE GI.OW �� 15 =- i r- -------------24'z 76•------- x 38' h � �� SOUTHERN 1 16 BIG WAVE 54"x 36" 4"SQUARE WOOD �'�,u 17 GIRL SURFER 36"x 36" 4"SQUARE WOOD / ^ -- ---- --- ' COASTLINE 7 1 80'x 25" 1 18 CABRILLO AVENUE GLOW 24"x 36" 4"SQUARE WOOD ,BUILT =___`____ ____ 14 0--- --- --- 4 h' ° ADJACENT ---- ��' z= — ——— ______ __ ________, --------- I TENANT xxi i --------- ==x� I N.I.C. MAXIMUM EIEI __________ ___ OCCUPANCY XXX _ -- ;13� RED SURF I 1 s 12' `-------------- -------� ------- 4 < FOR Q NX ® 500 11 1.OCCUPANCY SIGN SHALL COMPLY WITH ICC/ANSI A117.1 2 �u a EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE — r POSTED IN A CONSPICUOUS PLACE,NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE.POSTED i ii 16 SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT - DESIGN AND SHALL BE MAINTAINED BY THE OWNER OR AUTHORIZED AGENT. I J 2.PROVIDE"MAXIMUM OCCUPANCY"SIGNAGE CENTER MOUNTED I � o AT 6'-0"A.F.F _-Ti 2 ii �n ii i�i iiii �ii ii I 500 1 u w s u ii .I ii F— J 1 Lu CIO DIGIT&DSPAY u 1 fiiL SURFER al OCCUPANCY SIGNAGE � ; w F- � 1 SCALE: N.T.S GUNtD TOWER s00 ® s ~Y w Lu 0 u.z1 54'z 35' SfORYBOARD 3 SANTA ENSIGN 8 36' x 48" 1 J — I 500 SREEf SIGN CNRId1D i - -------- 5Cx38' I W� Z J i Z � — OOOIIPANOY I U rn m so 1 ROOM TO BASE OF TOP EliL__ NAME LINE OF TEXT LL EXIT I� TO BASE OF TO �J,J LINE OF TEXTS PAIp —� TO BASE OF _ < ® _ BRAILLE CHARACTERS - 0 BASE OF '� L - BRAILLE BRAILLE CHARACTERS - w x BRAILLE J p=#zR- U 1. TACTILE WALL MOUNTED SIGNAGE TO BE LOCATED AT 60"A.F.F.TO THE 1. TACTILE EXIT SIGNAGE SHALL BE INSTALLED WHERE REQUIRED BY - (n CENTERLINE OF THE SIGN ON THE LATCH SIDE OF THE DOOR AND SO ICC/ANSI A117.1 AND SHALL COMPLY WITH ICC/ANSI A117.1 - Q THAT A PERSON CAN STAND WITHIN 3"OF THE SIGN AND NOT BE HIT Z WITH THE SWING OF THE DOOR OR 9"O.C.FROM THE DOOR JAMB ON 2. FINISH AND CONTRAST OF THE SIGN SHALL COMPLY WITH THE PUSH SIDE OF THE DOOR. ICC/ANSI A117.1 Q (ICC/ANSI A117.1) Z 3. PROPORTIONS OF THE SIGN SHALL COMPLY WITH ICC/ANSI A117.1 a� Q 2. FINISH AND CONTRAST OF THE SIGN SHALL COMPLY WITH ICC/ANSI A117.1 4. CHARACTER HEIGHTS ON THE SIGN SHALL COMPLY WITH J ICC/ANSI A117.1 3. PROPORTIONS OF THE SIGN SHALL COMPLY WITH U) ICC/ANSI A117.1 5. RAISED CHARACTERS AND PICTORIAL SYMBOLS SHALL COMPLY WITH U ICC/ANSI A117.1 4. CHARACTER HEIGHTS ON THE SIGN SHALL COMPLY WITH ICC/ANSI Al17.1 6. BRAILLE ON THE SIGN SHALL COMPLY WITH[CC/ANSI A117.1 1= N o 7. MOUNTING HEIGHT AND LOCATION OF THE SIGN SHALL COMPLY WITH � ? Ln ICC/ANSI A117.1 N 0 a ROOM SSIGNAGE all TACTILE SIGNAGE O a GRAPHICS PLAN Z40 CENTER MOSAIC TILE ABOUT(4)TILES VERTICALLY&GROUT AS 2" \ON9Ep�ARC q'_g" REQUIRED SO NO PARTIAL MT TILES ARE CUT-FACE OF MOSAIC �o ,H,r �4:' TILE TO BE FLUSH W/SUBWAY TILE. PROVIDE 1/8"BACKING 9 U: CATILL :F i -0" -0" -0" (MR)AS REQUIRED.SEE DETAIL 7/A250 FOR MORE INFO _ __=+: CAR LE :�+= ■ o AR 19 ' I ac aA � ■ �•• O �13 T ■ A ■ 7A71 8 EQ. 15 EQ. ® 6 M� "I 10 ■ 11'-2" 6 7 � 7 N 2 0000 m m a 8C 3 m \ 12 5 a 8B - 60°x60"CLR. �■■■■■■■■■■■■■■■■■ ■■■■■■■■� � ��o mm ' ------------ ■ EJ N /ice— ■ 15 ® m 13 /� 11 13 3 D 13 / A 1O ■ 3 w .. /Lj 7 � I o i .m J OCUR. / \ 8C 813 A 11 O ■ J N .w . WOMENS RESTROOM ELEVATIONS3 R. 3 ■ 2 ro ;;�� a - ■ SCALE: 3/8°-1'-0° _6 11 9 a o ■ V_8"+/_ CENTER MOSAIC TILE ABOUT(4)TILES VERTICALLY&GROUT AS 1 ————— /I ■ 4'-6' REQUIRED SO NO PARTIAL MT TILES ARE CUT-FACE OF MOSAIC / ■ TILE TO BE FLUSH W/SUBWAY TILE. PROVIDE 1/8"BACKING =� 14 D B ,/ - 8 (ERR)AS REQUIRED.SEE DETAIL 7/A250 FOR MORE INFO �' 0 , `� 11 ■ 30"x48"CLR _ ' ———io—— 60x60"CLRJ A 10 ■ '' C 4 5 5 q p 2 B ■ hx4l CUR. ——— —_ ■ ��w 3 - 7A C ■ io 7A EQ. 17 E0. ® \\\�\ ■ m o 6—— � --- ---- - 7 \yL-. 6 r 54%60"CLR---- --------- —t �� OAR, \ ■ 48 x54'CLR——�.a"�. —— — —J I p\P, 1 ■ aXX 3 60 ■ 5 ■ 1•• I 1 77SC 12 5'-2 eA I I - I I •_ 1 s I > s I I <I mi > 2—]� // ■ HALLWAY --- ■ MENS RESTROOM ELEVATIONS a cos J l 2 9 ■ L——————48"x48' CLR. 54"x60'CLR. —— J ■ 3 ■ SCALE: 3/8'=1'-0' ■ LINE OF LINE OF SIDE WALL CEILING LINE OF REAR WALL SEE SHEET G120 FOR ADDITIONAL ACCESSIBILITY CODE REQUIREMENTS. 5-72 tMIN. "MAX. 54"MIN. C, V 12" FEMININE RESTROOM ADJACENT o TO DOOR SIGNAG 2 NAPKIN DISPENSER j 4 NOTE:PROVIDE STANDARD MIRROR SOAP DISPENSER SEE SHEEP A250EFOR DETAILED INFO 1 $EAT $EAT 39"'to 41" HEIGHT QN1Y IF(2) ��III PAPER HAND ____18"VERTICAL�� COVERS COVERS 18"VERTICAL URINALS ARE PRESENT TOWE DRYERENLARGED RESTROOM PL GRAB BAR 1 . j GRAB BAR I�� T.P. ___._.._. _�. ._.._.. .._.. .. YYY__ 011 CALE 1/2INSULATE ALL WATER S DRAIN PIPES o RESTROOM DOOR SIGNAGE- ® - - - TRASH SEE SHEET A250 RECEPTACLE a FOR DETAILED INFO 71' N 16"-18" WIDE SIDE OF TOILET APKIN DISPOSAL FIRE CONTROLS OUTLETS WATER CLOSETS URINALS TOILET ROOM ACCESSORIES SIGNAGE EXTINGUISHER AND SWITCHES J al TYPICAL ACCESSIBLE MOUNTING HEIGHTScli w SCALE: N.T.S W � � w � PROVIDE SOLID BLOCKING AS KOALA KARE PRODUCTS PROVIDE SOLID BLOCKING AS W M SHOWN-TWO FRAMING KB200-OS HORIZONTAL SHOWN-TWO FRAMING rn SPACES MINIMUM BABY CHANGING STATION SPACES MINIMUM HYwin Lu 3 FASTENERS EACH O On o SIDE OF BACK PANEL m Q INTO SOILD BLOCKING J ° - WALL SIGNAGE-ADJACENT TO DOOR y�6' y�6' TOILET ACCESSORIES ac RECESSED SEAT COVER DISPENSER-SEE DETAIL — o x FASTENER LOCATIONS- -i m 'I 'I 'I 'I 4/A250 FOR ADA ACCESSIBLE MOUNTING HEIGHTS. o i SEE FRONT ELEVATION Q 0 CERAMIC SUBWAY TILE TO ONLY BE Oj MIRROR- SEE DETAIL 4/A250 FOR ADDITIONAL CUTIN HALVES ONLY CONTRACTOR INFORMATION. R 9 BABY CHANGING STATION- SEE 5/A250 TO ADJUST MOSAIC TILES POSITION z w _ "� o (((��� - (((jjj BOBRICK STAINLESS STEEL PURSE HOOK. WOMEN'S CA AS NEEDED TO ACCOMMODATE O z " ^�o �¢"HIGH(MIN.) RESTROOM ONLY) 10 DOOR MOUNTED COAT HOOK ON STALL SIDE OF RESTROOM w 0 0 1'-11�6 w TOILET PARTITION DOOR.AT ACCESSIBLE RESTROOM AT LEAST rn w w w 3 ________ RAISED TEXT ______ O SOAP DISPENSER-OWNER PROVIDED,G.C.TO (1)SHALL NOT BE MOUNTED HIGHER THAN 48"A.F.F. w N QRAFN _ _ INSTALL PAPER TOWEL DISPENSER-OWNER PROVIDED,G.C. 11 STAINLESS STEEL WALL HUNG TOILET PARTITION = N TO INSTALL o z o w WALL MOUNTED LAVATORY WITH CHICAGO FAUCET Z BRAILLE-SEE ENLARGED DETAIL N w (MOUNT SO A PERSON MAY APPROACH o m O5 SEMI-RECESSED TRASH CAN -SEE DETAIL 4/A250 12 (333-E2805-665PSHAB) - J oY o? WITHIN 3"OF SIGNAGE WITHOUT o? FOR ADA ACCESSIBLE MOUNTING HEIGHT AND 30" X 48"CLEAR FLOOR SPACE IN FRONT OF N w w w LAVORATORY. SEE DETAIL 4/A250 FOR INFORMATION. a w OBSTRUCTIONS) m © 36"GRAB BAR. SEE G120 AND 4/A250 FOR FACE OF WALL o m < o m ADDITIONAL INFORMATION. TOILET WITH ADA COMPLIANT LEVER HANDLE MOUNTED FINISH FLOOR SURFACE UNE MOSAIC TILE WITH W ON ACCESSIBLE SIDE AND 48"CUR. FLOOR SPACE HORIZONTAL GROUT LINES Oj 42"GRAB BAR. SEE G120 AND 4/A250 FOR 13 FRONT of THE OF THE TOILET SEE G120 AND 4/A250 ADDITIONAL INFORMATION. FOR ADDITIONAL INFORMATION. FRONT VIEW S��E VIEW Q 5 6 RESTROOM SIGNAGE STANDARDS a MOSAIC TILE ,A 18"VERTICAL GRAB BAR. SEE 0120 AND 4/A250 FOR H a ULTRA LOW FLOW URINAL WITH 30"X 48"CLEAR BABY CHANGING STATION SCALE N.T.S ADDITIONAL INFORMATION. 14 FLOOR SPACE IN FRONT OF URINAL SEE DETAIL SCALE: 1'=1'-0' a SCALE: N.T.S ® SEAT COVER/TOILET PAPER DISPENSER/(FEMININE 4/A250 FOR ADDITIONAL INFORMATION. W NAPKIN DISPOSAL AT WOMEN'S).SEE DETAIL 4/A250 I� C.7 FOR ADA ACCESSIBLE MOUNTING HEIGHTS. 15 MTi (MEWS RM.)/MT2 (WOMEN'S RM.) - RECYCLED o GLASS MOSAIC TILES. ® RECESSED TOILET PAPER DISPENSER-SEE DETAIL REFER TO SPECIFICATIONS DIVISION 10 FOR SPECIFIC PRODUCT 4/A250 FOR ADA ACCESSIBLE MOUNTING HEIGHTS. INFORMATION L\ z 88 RECESSED TOILET PAPER DISPENSER/FEMININE = p W NAPKIN DISPOSAL- SEE DETAIL 4/A250 FOR ADA ACCESSIBLE MOUNTING HEIGHTS. A ^^O TABLE SCHEDULE 0=TABLE NOT USED TABLE TYPE DESCRIPTION SEATSPER NUMBER SEATS PER INTERIOR TABLES TABLE OF TABLES TABLE TYPE I I �2;• .;yirG SI�OE U: CARLL•••F li ��2� li a L I g /� � I _:/t LINGLE •:�= /L, I N � •l� 1 _ �,�`v N 1 c AR-2319 ,% 1 3 ADA PULLMAN BOOTH 4 2 8 F' i -����--� /�G•••• - N I i B-1L B-1L a S � 1 T-"L.1 N �X� N � I I , 2 4 i�._.� lam! \ a s I I 1 ( a ® 1 a 1 II 3 © B-1 L T O L III B-1 L LOW PULLMAN BOOTH 4 3 12 1 w N 2 4 cp R 1 ❑ 1�:J LOW 2 TOP TABLE W/ l,�I I I - - N © 1 S21 (1)S-1 L CHAIR 2 2 4 ----- ——— I FOOD PIS —��I � \ FIXED FIXED LOW 2 TOP TABLE III 2 ov!(1)s-iLCHAR 2 �� II�� G'y\ T-2Lf _ 0 24w18r� V L ADA LOW 2 TOP TABLE 1 I� �I W/(2 SAL CHAIR 2 1 2 I r-Y II I �N---r 1 99 LOW PULLMAN 1 Cr 21L DEUCE BOOT O H 2 10 20 = \ ® 1 B-1L T- L -- lZ-1 l 1 .. I ___� I 92 1 18 9 O I' lil 1 B-IL 3 li i I m I I I I 1 I I O "- � ADA CUSTOM LOW PULLMAN 6 15 1 16 1- - ___� ----�-QGD T-4L.i �.,�'I lZ-1 BOOTH III lil 2 1 7 1ll- 4 B-IL 10 O 13 _ O F 1 5 ADJACENT -li - - - - - -1— -�- i m TENANT __ - 17 *J ----- m II 1 B-)L 3 lil lil I N.I.C. H III T-4L CUSTOM LOW PULLMAN 6 NOTE: 4--m-5 11 AR, I aocrH FOR REFEALL ACCESSIBLER TO SHEET 20 & A250 -- ^ ' REQUIREMENTS AND PARAMETERS ` O N 1 4 B-IL 6 5 s J 1 -L—- -- -- - - -,-- -- -- -- -- - -- - - -- - - A 1 � II U I i I i' 101 201 1 0 - ADA LOW 2 TOP TABLE 4 _ _ I. 21^ `IJ T-2L.3 WI(4)S-1L CHAIR �r�.;I IL `--- Cr J °' IK��II _ i =f a 361°24 S-2H S-2H S-2H S-2H S-2H 31 30 29 28 27 �N L � LOW)TOP TABLE - I i T-2L 1, W!(2)S1L CHAIR 2 421°18 1 �\ 3 1 221 I __ ® S32S-3 3 3 HIGH PULLMAN 4 0u2_3� 2H 2H S-25H S- I �T-1H BOOTH 54e18 22 4 HIGH PULLMAN 2 O 24 mDEUCE BOOTH -2L.1 L 5651 02 53i I. m�Nc-r HIGH 2 TOP TABLE W/ _ _ L; -- (1)s-zHCHAIR 2 SEAT NUMBER FOR �:as9`v T-2H S-2 REFERENCE ONLY -_ - _ O _ _ O _ _ O 3I r n 0 H 1 41 39 - - B iL li I Tl2H.i - - --- -- I I T 2L.111 42 40 ® cli -- - -- -- - B 1 L B i L IT 2L.111 B 1 L B i L IT-2L.111 B-1 L ----- - N I --- FIXED HIGH 2 TOP TABLE I 2 �- -_- - II I _ -----1 T-'CL.1�B-1 L _� 26� P�III XID W/1 2HCHAIR -- -- - 50 F 49 48 F 47 46 F 45 B-1L 1 T-CL.1 B-1L B-1L 1 Y-�I 1 --- --I+- -- - 44 Ill 38 I I I i m 30VV 2 TOP TABLE _ _ J--{I L ; LLI I-� W/(1)S-2H CHAIR III 2 0 C Lu III - _--- I 3-6 W HIGH 2 TOP TABLE W/ 2 I FIXTURE AND EQUIPMENT PLAN GENERAL NOTES: w M 2 T-2N 2 1 ()S-211 CHAIR - - co I I 1. (1)WHEELCHAIR SEATING FOR EVERY(20)SEATS,WITH AT LEAST ONE PER EACH FUNCTIONAL AREA Y LI_I p LLJ S-12H S-2H S-32H S-42H S-r�2H OF THE ESTABLISHMENT.SPACE MIN.36"W.CLEAR AISLE&SEATS SHALL PROVIDE A TABLE OR 57 I �1 m Q O Vj 2 COUNTER HEIGHT OF 28"TO 34"ABOVE FLOOR W A 27"H.x 30"W.x 19"D.KNEE SPACE U 3 HIGH TOP COMMUNITY O UNDERNEATH 1 TABLE W/(10)S-2H CHAIRS 10 1 10 2. ALL INTERIOR TABLES,BOOTHS,AND HALF WALLS IN DINING ROOM TO BE PROVIDED AND INSTALLED Z Z J 10 9 8 7 6 BY FURNITURE VENDER UNLESS NOTED OTHERWISE. S-2H S-2H S-2H S-2H S-2H 581 \ 5 U � m 3. ALL INTERIOR TABLES THAT ARE NOTED TO BE FIXED WILL BE ANCHORED INTO FLOOR SLAB BY O TOTAL INTERIOR TABLE&SEAT COUNT 19 56 FURNITURE VENDER UNLESS OTHERWISE NOTED. EXTERIOR TABLES 4. ALL EXTERIOR TABLES TO ARE NOT FIXED. O 13 1 T-1E 9 EXTERIOR 2TOP TABLE W/ 5. ALL PATIO FURNITURE FURNISHED BY OWNER ----_T J 1 li 3L (2)S 3L CHAIRS- 2 7 14 9 \ 6. ALL PATIO HEATERS TO BE PROVIDED AND INSTALLED BY G.C. I T T-1E _ 661 - S-1L -1L 7. IF MUSHROOM PATIO HEATERS ARE USED HEATERS ARE TO BE FIXED INTO SLAB AND RAN OFF OF F 69 70 Z ' I _ W --- --- NATURAL GAS UNLESS NOTED OTHERWISE.SEE MECHANICAL SHEETS FOR ADDITIONAL INFORMATION. DA 0 �I T-2E_1� A W/(4 S3 CHARS TABLE 4 1 4 60, 68 T-1E 67` 6 1 FIXTURE AND EQUIPMENT PLAN KEYED NOTES: ;� s�L 111E �- �.•_..\ Cl O7 FURNITURE VENDER TO FIX TABLE TO FLOOR/WALL DEPENDING ON LOCATION. ; w 8 1 8 O WALL MOUNTED LOCKABLE KEY CABINET(THE CONTRACTOR GROUP COORDINATE 711336) 61 TOTAL EXTERIOR TABLE&SEAT COUNT -INSTALL TOP OF CABINET®60"A.F.F. CONTRACTOR TO COORDINATE 5 5 Q LOCATION WITHIN OFFICE AS REQUIRED RESTAURANT TOTAL SEAT COUNT(INTERIOR&EXTERIOR) 27 74 LLJ O DESK W/20"DEEP SHELVING ABOVE-SEE 2/E210 FOR ADDITIONAL ADDITIONAL SEATING INFORMATION. 62 1 LINEAL TOTAL ALTECH 9'COMMERCIAL MARKET UMBRELLA PROVIDED AND INSTALLED BY BENCH TYPE DESCRIPTION FEET CAPACITY ® 63 g4 0 OPERATIONS-SEE 6/A270. O Z CUSTOM WAITING BENCH SUNGLO PERMANENT POST HEATER PROVIDED AND INSTALLED BY G.0 (V OV B-2L 2LF PER PERSON 5 3 L LF/2=TOTAL CAPACITY O (UNDERGROUND VAULT.UNDERGROUND CONDUIT AND GAS LINE BY LANDLORD CONTRACTOR.) MODEL NUMBER:PSA265 V,OVERALL HEIGHT:93 IN.,FUEL N 0 TOTAL ADDITIONAL SEATING COUNT 3 TYPE:NATURAL GAS,lYR NOMINAL SPACING:12 FEET,FINISH:SS. 1 FIXTURE AND EQUIPMENT PLAN a SCALE: 1/4'=T-0° F_A260 25EDIARCh q�O ••arc 8 U: CABLL•:6`C LINGLE o AR-2319 e I 1 'kj ma � m� E J N !I FLOOR PLAN KEYED NOTES: 0 3 3 ^m J O PATIO CONCRETE BY LANDLORD UNDER SEPARATE PERMIT J N a LANDSCAPED AREA BY LANDLORD UNDER SEPARATE PERMIT __ =•�- •, 'if .' ,`��+�__ _ HABIT BURGER TO PROVIDE LANDLORD SHELL CONTRACTOR WITH PATIO HEATER VAULT BOX. LANDLORD CONTRACTOR TO SET VAULT BOX WITH ACCESS HATCH AT FINISHED CONCRETE HEIGHT. LANDLORD CONTRACTOR ALSO TO PROVIDE O UNDERGROUND GAS AND ELECTRICAL CONDUITS TO LOCATIONS SHOWN FOR PATIO HEATERS. HABIT G.C.TO COMPLETE FINAL CONNECTIONS. REFERENCE -- -- — - EPLUMBING AND ELECTRICAL PLANS FOR MORE INFORMATION.SEE DETAIL 4/A270 O NEW PATIO RAILING PROVIDED AND INSTALLED BY CONTRACTOR REFER TO DETAILS 2/A270 AND 3/A270 FOR TYPICAL FABRICATION INSTRUCTIONS O a5 PATIO HEATER 6 PATIO UMBRELLA — SCALE: N.T.S a SCALE: N.T.S -- II II I I I I A NEW_ II I I I II I I I I �I d 1 6-1/2"W x 12"D x 15'T UNDERGROUND VAULT BOX = F GAS SERVICE PIPE - INTEGRAL METAL BRACKET/ �/ SLEEVE WITHIN VAULT BOX �YV� FOR POLE TO INSERT INTO /1 K L J 24"x24"15"OF 3/4"CLEAN — - GRAVEL BED BELOW 3 = UNDERGROUND VAULT BOX � 1, 6 1/z 12" \ 1 PATIO HEATER UNDER- al GROUND VAULT DETAIL. L�04 -- I I w 70 1-1/2"x 1-1/2'TUBE STEEL TOP 1-1/2•x 1-1/2"TUBE STEEL TOP 3'-0"TP. RAIL W/BENJAMIN MOORE ACRLIC RAIL W/BENJAMIN MOORE ACRLIC Yi LJ� BETWEEN ALL POST AURA SERIES SEMI-GLOSS FINISH AURA SERIES SEMI-GLOSS FINISH BLACK PAINT BLACK PAW 4 rn LLT F TYPICAL 1-1/2-SQUARE%BE — POST W/BENJAMIN MOORE ACRLIC I—Y LLI Q Lu AURA SERIES SEMI-GLOSS FINISH ¢I ,yam //� BLACK PAINT • Q O (n V 1-1/2•SQUARE TUBE POST W/ 4• TYPICAL 3/C SQUARE TUBE STEEL BENJAMIN MOORE ACRUC AURA TYP. VERTICAL PICKET W/BENJAMIN SERIES SEMI-GLOSS FINISH BUCK 4 =Z J Q MOORE ACRLIC AURA SERIES PAINT SEMI-GLOSS FINISH BIACK PANT 0 - w y\ Z_ J 1-1/2"SQUARE TUBE STEEL Z 11'� BOTTOM RAIL W/BENJAMIN MOORE 1-I/2•SQIIPRE TUBE STEEL )(J< U m ACRLIC AURA SERIES SEMI-GLOSS BOTTOM RAIL W/BENJAMIN MOORE /\ FINISH BUCK PAINT ACRLIC AURA SERIES SEMI-GLOSS FINISH BLACK PAW II4IE:GRIND ALL FENCING WELDS PND EDGES SMOOTH AND TOUCH-UP FlNISH AS REWIRED 4•DIA.CORE DRILLED IN SLAB FOR POSTS.SET POST IN EPDXY FLOOR STONE-TUE. - - F - NOTE:1/4'THICK e 6"SQUARE STEEL BASE PLATE-WEIOED TO VERTICAL POSTS WITH (4)1/2"HOLES k(4)1/3•'00-3/4"MIN.HILD REDHEAD GALVANIZED STEEL EXPANSION cD ANCHOR OR DRILL-IN EPDXY-SET ANCHOR BOLTS 0 EVERY OTHER TYP RAILING POST BANDS ACCESS PANELS AS REQUIRED FOR WATER AND POWER 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 18'-1J2" al PATIO RAIL DETIAL al PATIO RAIL SECTION 1 z SCALE: .4-0- SCALE: 1.4-0• Q aPATIO PLAN SCALE: N.T.S. o N O � A270 EXISTING STRUCTURE ABOVE EXTEND TYPE X GYP. 3-5/8"KICKERS(362S125-30) 3-5/8"KICKERS(362S125-30) 3-5/8"KICKERS(362S125-30) 3-5/8"KICKERS(362S125-30) FACE OF EXISTING DEMISING WALL- EXISTING STRUCTURE ABOVE BOARD TO EXISTING ROOF��i'i ii'i EXISTIAGDJATRNT TTUERA TROVE DIRECTION ATTACHED TO STRUCTURE ABOVE NATE DIRECTION ATTACHED TO STRUCTURE ABOVE NATE DIRECTION TO STRUCTUATTACHED AT 4'O.C.REA ABOVE NATE DIRECTION ATTACHED TO STRUCTURE ABOVERNATE STUDS SECURE-NEW MAINTAN PARTNION EXISTING FlRE ARCh�ri DECK AND FIRE SEAL ALL JOINTS AND PENETRATIONS RATED CONSTRUCTION �'• ADJACENT TENANT -- EXISTING DEMISING WALL SUSPENDED WASHABLE STUD TDP TRACK SUSPENDED WASHABLE STUD TOP TRACK SUSPENDED WASHABLE STUD TOP TRACK 6"20GA @ i6"O.C. STUD TOP TRACK g U: CAFaLL•:Fp EXISTING DEMISING WALL TOP TRACK AT FIELD VERIFY COMPLIANCE LAY-IN CEILING TILES IN 362T125-33 LAY-IN CEILING TILES IN 362T125-33 LAY-IN CEILING TILES IN 362T125-33 362T125-33 _=+; LINGLE ANCHOR TOP METAL STRUCTURE WITH 1 HOUR FIRE KITCHEN AREA KITCHEN AREA KITCHEN AREA (6005125-30) - _ FIELD VERIFY COMPLIANCE TRACK TO EXISTING 362T200-54 RESISTIVE CONSTRUCTION .r—=— - 5/8"GYP.MOISTURE m STUD TOP TRACK M2319 WITH 1 HOUR FIRE (6 20GA @ i) O.C. a STRUCTURE AT 24"O.C. REQUIREMENTS PROTECT R13 SOUND BATT INSUL RESISTANT WALLBOARD 362T125-33 e ; 5 8"GYP.WALLBOARD 6005125-30 `�. RESISTIVE CONSTRUCTION - / ( ) 7" STUD TOP TRACK DURING CONSTRUCTION.- 5/8"GYP.WALLBOARD 5/8"GYP.MOISTURE REQUIREMENTS-PROTECT FILL VOID BETWEEN 4- KITCHEN CERAMIC WALL TILE W/ R13 SOUND GATT INSUL 5 8"GYP.MOISTURE DURING CONSTRUCTION.- DOUBLE TOP TRACK 8 362T125-33 G.C.REQUIRED TO PATCH INTEGRAL COVED BASE RESISTANT WALLBOARD / I G.C.REQUIRED TO PATCH WITH EATING INSULATION AND REPAIR HABIT BURGER FRY OVER 5/8" RESISTANT WALLBOARD SIDE IF NECESSARY. 5/8^TYP"X"GYP.BD.OVER PLYWOOD IN KITCHEN CERAMIC WALL TILE W/ CERAMIC WALL TILE W/ AND REPAIR HABIT BURGER _ -ALLOW FOR Yz" INTEGRAL COVED BASE INTEGRAL COVED BASE SIDE IF NECESSARY. 5 8"TYP"X"GYP.BD.OVER - METAL STRAPPING BEHIND 3 5 8"20GA @ 16"O.C. - - CERAMIC WALL TILE W/ MOVEMENT IN DOUBLE / / METAL STRAPPING BEHIND HOOD AS REQUIRED.FRP 362S125-30 - INTEGRAL COVED BASE - w o w TRACK ASSEMBLY ffi ( ) HOOD AS REQUIRED.5/8" OVER 5/8"PLYWOOD IN 5/8"GYP.WALLBOARD @ o i o 0 5/8"TYPE X GYP. ,,, z KITCHEN/FOOD PREP LL HALLWAY LL HALLWAY-FRP FROM FLOOR WALLBOARD EACH SIDE PLYWOOD SHEATING @ALL a < KITCHEN AREA < TOILET ROOM 3 5 8"20GA @ 16"O.C. 7^ DINING AREA 7 OVER 5 8 PLYWOOD IN PREP 7 / 1 OTHER LOCATIONS-SEE 3 5/8"20GA @ 16"O.C. 4g 48' DINING AREA /" 7„ 3 5/8"20GA @ W O.C. 48 (362S125-30) 44 5/8"PLYWOOD FLOOR PLAN FOR ADD INFO. EXPO 3 5/8"20CA @ 16"O.C. 4 r N ADJACENT TENANT DINING - - _ (362S125-30) _ 12"TALL 5 8"DUROCK - 8 _ (362S125-30) / (362S125-30) TOILET ROOM FRP OVER SHEATHING FROM STAINLESS STEEL WALL - 12"TALL 5/8"DUROCK @ BOTTOM OF WALL TILE BASE W/ - - - _ _ w m ^p, FLOOR TO SCHEDULE CEILING COVERING OVER SHEATHING @BOTTOM Of WALL CLEAR SILICONE 12"TALL 5/8"DUROCK @ 12"TALL 5/8"DUROCK @ - 4�" m aTILE BASE W/CLEAR KITCHEN AREA FROM FLOOR TO CEILING 3/8"COVED EPDXY BASE W/ SEALANT @TOP BOTTOM OF WALL @KITCHEN BOTTOM OF WALL BOTH SIDES o 12"TALL 5/8"DUROCK 3/8"COVED EPDXY BASE W/ CLEAR SILICONE SEALANT @ OF BASE 12"TALL 5/8"DUz .o m SILICONE SEALANT @ TOP @ BOTTOM OF WALL 12"TALL 5/8"DUROCK N BOTTOM OF WALLOFBASE @BOTTOM OF WALL CLEAR SILICONE SEALANT @ TOP OF BASE 3/8"COVED EPDXY BASE W/ w N3 5/8"20GA @ 16"O.C. STUD SILL TRAC TOP OF BASE STUD SILL TRACK STUD SILL TRACK CLEAR SILICONE SEALANT® STUD SILL TRACK STUD SILL TRACUD SILL TRAC m(3625125-30) 362T125-33 3/8"COVED EPDXY BASE W/ 362T125-33 362T125-33 TOP OF BASE 362T125-33 TOILET ROOM 362T125-33 TOILET ROOM2T125-33 o z ..KITCHENCLEAR SILICONE SEALANT® FOOD PREP ° FOOD PREPiTOP OF BASE - - HALLWAYANCHOR METAL TRACK TO ANCHOR METAL TRACK TO ANCHOR METAL TRACK TO ANCHOR METAL TRACK TO ANCHOR METAL TRWITH IOH SHALL COMPLY PARTITION SHALL COMPLYNOTE: NOTE:CONCRETE SLAB w/HILTI CONCRETE SLAB W/HILTI XU CONCRETE SLAB W/HILTI XU CONCRETE STAB W/HILTI XU CONCRETE SLAB WPROVIDE GATT INSULATION PROVIDE BATi INSULATIONWITH 1 HOUR FIRE RESISTIVE XU TYPE FASTENERS ® PARTITION SHALL COMPLY WITH 1 HOUR FlRE RESISTIVE TYPE FASTENERS @ 18"O.C.- TYPE FASTENERS @ 18"O.C.- FOR SOUND IN ALL WALLS TYPE FASTENERS @ 18"O.C.- FOR SOUND IN ALL WALLS TYPE FASTENERS @ASSEMBLY REQUIREMENTS 18" O.C. TYP. PER ACC WITH 1HOURFIRERESISTIVE ASSEMBLY REQUIREMENTS TYP PER ACC ESR#2269 TYR PER ACC ESR#2269 SHARING A RESTROOM WALL. TYR PER ICC ESR#2269 SHARING A RESTROOM WALL. TYR PER ICC ESR ESP #2269 TYP. ASSEMBLY REQUIREMENTS NOTE:INSTALL MOISTURE-RESISTANT NOTE:INSTALL MOISTURE-RESISTANT GYP BOARD BEHIND WALK-IN GYP BOARD BEHIND WALK-IN O EXISTING DEMISING WALL•DINING 2 DEMISING WALL•KITCHEN 3 EXIST.DEMISING WALL•KITCHEN 4 PARTITION FREEZER/COOLERS 5 PARTITION FREEZER/COOLERS 6 TOILET ROOM PARTITION 7 TOILET ROOM PARTITION a TOILET ROOM FURRING SAME CONSTRUCTION AS PARTITION ABOVE.USE 6" EXIST.DEMISING WALL @ TOILET ROOM-SAME SAME CONSTRUCTION AS PARTITION ABOVE.USE 6" SAME CONSTRUCTION AS PARTITION ABOVE.USE 6" SAME CONSTRUCTION AS PARTITION ABOVE.USE 6" SAME CONSTRUCTION AS PARTITION ABOVE.USE 6" SAME CONSTRUCTION AS PARTITION ABOVE.USE 6" 2A 20GA(60OS125-30)METAL STUDS @ 16"O.C.IN 3A CONSTRUCTION AS PARTITION ABOVE.USE 5/8" aA 20GA(60OS125-30)METAL STUDS @ 16"O.C.IN 5A 20GA(60OS125-30)METAL STUDS @ 16"O.C.IN 6A 20GA(600S125-30)METAL STUDS @ 16 O.C.IN LIEU 7A 20GA(60OS125-30)METAL STUDS @ 16 O.C.IN LIEU SA 20GA(60OS125-30)METAL STUDS @ 16 O.C.IN LIEU LIEU OF STUDS CALL OUT ABOVE. MOISTURE RESISTANT GYP.BD.SHEATING IN LIEU LIEU OF STUDS CALL OUT ABOVE W/6"STUD LIEU OF STUDS CALL OUT ABOVE W/6"STUD OF STUDS CALL OUT ABOVE W/6"STUD TRACKS OF STUDS CALL OUT ABOVE W/6"STUD TRACKS OF STUDS CALL OUT ABOVE W/6"STUD TRACKS OEXISTING FRAMING BY LANDLORD. HABIT OF PLYWOOD.CERAMIC TILE OVER GYP.BD. TRACKS(60OT125-33). TRACKS(60OT125-33). (60OT125-33)&R19 SOUND BATT INSUL. (600T125-33)&R19 SOUND BATT INSUL (60OT125-33). 26 G.C.TO PROVIDE WALL SHEATHING AS SAME CONSTRUCTION AS PARTITION ABOVE.USE 2 1/2" 8B SAME CONSTRUCTION AS PARTITION ABOVE.USE 2 1/2" ILLUSTRATED ABOVE 4B 20CMA(250S125-30)METAL STUDS @ 16"O.C.IN LIEU O 20CMA(250S125-30)METAL STUDS @ 16"O.C.IN LIEU OF STUDS CALL OUT ABOVE W/2 1/2"STUD TRACKS OF STUDS CALL OUT ABOVE W/2 1/2"STUD TRACKS FACE OF EXISTING DEMISING (250T125-33)&2 1/2"KICKERS(250S125-30)@ (25OT125-33) 2x8 WD BLOCKING RIPPED ki"X 1 14"WHITE SLATS WALL/EXTERIOR WALL-SECURE NEW 4'O.C.MAX.ALT.DIR. SECURLY FASTENED TO 1)�" , FRAMING TO EXISTING STUDS- TO 6"WIDE x/4 STONE TOP PLATE _ DIA.POWDER COATED STEEL MAINTAIN PARTITION FIRE RATED 3-5/8"KICKERS(3625125-30) STAINLESS STEEL TOP VARIES POST FACE OF EXISTING EXTERIOR CONSTRUCTION AS REQUIRED ATTACHED AT 4'O.C.MAX.ALTERNATE 2'-2" BY F.S.E.C. FILLER TO CREATE FLUSH FACE OF EXISTING EXTERIOR SUSPENDED WASHABLE DIRECTION TO STRUCTURE ABOVE FRONT �'4"STONE TOP PLATE WALL-SECURE NEW FRAMING WALL-SECURE NEW FRAMING LAY-IN CEILING TILES IA�� SUSPENDED WASHABLE y_X 74'C-CHANNEL TO EXISTING STUDS TO EXISTING STUDS KITCHEN AREASTUD TOP TRACK LAY-IN CEILING TILES IN STUD TOP ® ® �s"METAL BASE PLATE STUD TOP TRACK WIOOD BLOCKING SUSPENDED WASHABLE SUSPENDED WASHABLE KITCHEN AREA150T125-33 KITCHEN AREA TRACK STUD TOP TRACK BOLTED TO BLOCKING 250T125-33 STUD TOP TRACK �s BAMBOO WOOD SLATS ON LAY-IN CEILING TILES IN = LAY-IN CEILING TILES IN FOOD PREP FOOD PREP 362T125-33 600T125-33 F-i STNNLESS STEEL PANELS BY �,�, WOOD BLOCKING KRCHEN AREA `O KITCHEN AREA 362T125-33 FRP/S.S.WALL KITCHEN "PLYWOOD CARRIER TO BEBAMBOO WOOD --- EXTERIOR WALL@ EXTERIOR WALL@ 5/8"TYP"X"GYP.BDCOVERING OVER 5/8" 5/8"TYR"X"GYP.BD.OVER 2x2 TUBE STEEL F.S.E.C.FROM UNDERSIDEINSTALLED BY MILLWORKMETAL STRAPPING BEHISHEATHING IN KITCHEN METAL STRAPPING BEHIND& POST IN SLEEVE @ OF SS TOP TO 2' BELOW y"" SLATS 5/8"GYP.MOISTURE STOREFRONT SYSTEM OFFICE/FOOD PREP STOREFRONT SYSTEM 18"BEYOND HOOD AS -SEE FINISH PLAN 18'BEYOND HOOD AS48"O.C.-BOLT LOWER COUNTER/EQUIP RESISTANT WALLBOARD FRP OVER 5 8 PLYWOOD R13 BAIT INSUL REQUIRED.5/8"PLYWOFOR ADD.INFO REQUIRED.5/8"PLYWOOD POST SLEEVE TO ASP PANEL AT EA SIDE SIDE CERAMIC WALL TILE W/ CONIC.SLAB W/(4) (2)LAYER Ys' 3 5/8"20GA @ 16"O.C. SHEATING®ALL OTHER SHEATING @ ALL OTHER -RUN PANEL 2"ABOVE WD INTEGRAL COVED BASE LOCATIONS-SEE FLOOR PLAN LOCATIONS-SEE FLOOR PLAN 3/8"BOLTS- BLOCKING TO BE TRIMMED Y"PLYWOOD PLYWOOD - REQUIRED FOR SHIM AS FOOD PREP REQUIRED FOR TRUE AND FLAT FOR ADD INFO. FOR ADD INFO. 7• EPDXY BOLTS INTO BY F.S.E.C. 1" 1 5/8"20GA @ 16"O.C. 3 5/8"20GA @ 16"O.C. 4g OFFICE CONIC. •M ! 2 1/2"20GA @ 16"O.0 BEHINDWALL URFACE OFFICE EOFFlCE 44 1^ 5/8"GYP.BD.EA.SIDE - 3 METAL STUD X 20 GA @ 3%"METAL STUD X (250S125-30)SHIM AS 1 (162S125-30)SHIM AS 2g (362S125-30) - 3 REQUIRED FOR TRUE AND FLAT 6"20CA @ 16"O.C. �iti 16"O.C. 20 GA @ i6"O.C. REQUIRED FOR TRUE AND FLAT 8 12"TALL 5/8"DUROCK @ WALL SURFACE ADJACENT 12"TALL 5/8"DUROCK @ yi,� ��E 60OS125-30) - FILLER TO CREATE FLUSH WALL SURFACE BOTTOM OF WALL TENANT BOTTOM OF WALL 11 FRONT 12"TALL 5 8 DUROCK 12"TALL 5 8"DUROCK @ XPO / SPACE/EXTERIOR WALL 3 8"COVED EPDXY BASE W _ STUD SILL KITCHEN Yx"X Yx"C-CHANNEL BOTTOM OF 3/8"COVED EPDXY BASE W/ BOTTOM OF WALL / / - COOKLINE 3/8-COVED COVED EPDXY BASE W Ys"X N�"C-CHANNEL ® ® CLEAR SILICONE SEALANT @ 3 8"COVED EPDXY BASE W CLEAR SILICONE SEALANT @ TRACK i i / / TOP OF BASE STUD SILL TRACK / / STUD SILL TRACK TOP OF BASE 362T125-33 CLEAR SILICONE SEALANT @ 6"TILE BASE W TOILET ROOM STUD SILL TRACK CLEAR SILICONE SEALANT @ 150T125-33 0 12"TALL 5/8" TOP OF BASE ICI / ° 6"TILE BASE _ 250T125-33 362T125-33 TOP OF BASE ° DUROCK @ CONCRETE BACKING 1. 1BOTTOM OF WALL EXPANSION ANCHOR -g - - - ANCHOR METAL TRACK TO ANCHOR METAL TRACK aO 6"3M PROTECTIVE SEALER ° ANCHOR METAL TRACK TO ANCHOR METAL TRACK TO CONCRETE STUD SILL TRACK HILTI%"DIA. 'KWIK TZ"EXPANSION " °_� SLAB w HILTI XU TYPE CONCRETE SLAB W/HILTI CONCRETE SLAB W/HILTI BOLTS @ 32"O.C.ICC-ESR#1917 OVER MARBLE-TYP.SPEC: CONCRETE SLAB w/HILTI / 600T125-33 XU TYPE FASTENERS @ XU TYPE FASTENERS @ XU TYPE FASTENERS ® FASTENERS ® 18" O.C. TYP. 18"O.C.-TYR PER ICC 18"O.C.-TYR PER ACC NOTE:INSTALL MOISTURE-RESISTANT 4"CONIC.CURB-EPDXY#4 O 18" O.C. TYP. PER ACC PER ACC ESP #2269 TYP. BARS INTO EXIST GONG.SLAB 13 DIVIDER HALF WALL ESR#2269 ESR#2269 GYP BOARD BEHIND WALK-IN -- ESR #2269 TYP. FREEZER/COOLERS SIMILAR TO SERVICE COUNTER DETAIL ON SHEET A400. O SECTION/DETAIL O PARTIAL ELEVATION NOTE:OWNER/VENDOR RESPONSIBLE 1 a STOREFRONT FURRING•TOILET ROOM s 1 5/8'KITCHEN/FOOD PREP FURRING o KITCHEN/FOOD PREP PARTITION COOK LINE HALF WALL FOR SUPPLYING AND NSTALNNc s STOREFRONT FURL•BACK OF HOUSE PARTITION#13 SAME CONSTRUCTION AS PARTITION ABOVE.USE 3 5/K 6"KITCHEN/F.P.FURRING-SAME CONSTRUCTION AS SAME CONSTRUCTION AS PARTITION ABOVE.USE 6" 12 DIVIDER HALF WALL 14A 20GA(362S125-30)METAL STUDS @ 16"O.C.IN LIEU STOREFRONT FURRING @OFFICE-SAME CONSTRUCTION AS 9A PARTITION ABOVE.USE 6"20GA(60OS125-30)METAL 10 20GA(60OS125-30)METAL STUDS @ 16"O.C.IN OF STUDS CALL OUT ABOVE 15A PARTITION ABOVE USE 6"20CA(60CS125-30)METAL STUDS @ STUDS @ 16"O.C.IN LIEU OF STUDS CALL OUT ABOVE LIEU OF STUDS CALL OUT ABOVE W/6"STUD 16"O.C.IN LIEU OF STUDS CALL OUT ABOVE&R19 BATT INSUL. W/6"STUD TRACKS 600T125-33 TRACKS 600T125-33 SAME CONSTRUCTION AS PARTITION SAME CONSTRUCTION AS PARTITION ABOVE USE 6" ( ) ( ) 12A ABOVE.USE 6"20 GA(600S125-30) NOTE:RUNS INTEGRAL COVED BASE NOTE: 12"TALL 5/8"DUROCK @ NOTE:FRP OVER SHEATHING FROM 14B 20GA STOREFRONT FURRING @KITCHEN-SAME CONSTRUCTION AS 3 5/8"KITCHEN/F.P.FURRING-SAME CONSTRUCTION SAME CONSTRUCTION AS PARTITION ABOVE.USE 2 1/2" NOTE:3/8"INTEGRAL COVED BASE METAL STUDS @ 16"O.C.IN LIEU OF THAT RUNS MIN.4"UP WALL®ALL BOTTOM Of WALL OF ALL WET AREAS FLOOR TO SCHEDULE CEILING FOR ALL O STUDS CAL UT METAL STUDS @ 16"O.C.IN LIEU 156 PARTITION ABOVE.USE 2 1/2"20GA(2505125-30)METAL STUDS J 9B AS PARTITION ABOVE.USE 3 5 8"20GA 362S125-30 1 OB 20GA 250S125-30 METAL STUDS @ 16"O.C.IN LIEU THAT RUNS MIN.4"UP WALL @ ALL STUDS CALLED ABOVE. WET AREAS(FOOD PREP,KITCHEN, (KITCHEN,TOILET ROOM,ETC.)U.N.O. WALLS IN KITCHEN&OFFICE U.N.O. OF STUDS CALL OUT ABOVE&R19 BATT INSUL IN @ 16"O.C.IN LIEU OF STUDS CALL OUT ABOVE&2"RIGID INSUL. / ( ) ( ) LIEU OF RIGID INSUL. o METAL STUDS @ 16"O.C.IN LIEU OF STUDS CALL OUT OF STUDS CALL OUT ABOVE W 2 1/2"STUD TRACKS WET AREAS FOOD PREP,KITCHEN, EXPO,TOILET ROOMS,ETC.)WALLS- / / ( EXISTING SHELL BUILDING FRAMING. HABIT G.C.TO ABOVE W 3 5/8"STUD TRACKS 362T125-33 (250T125-33)&2 1/2"KICKERS(2505125-30)@ EXPO,TOILET ROOMS,ETC. WALLS- SEE EPDXY&COVE BASE NOTES ON NOTE:FOR KICKER ATTACHMENTS SEE NOTE:G.C.RESPONSIBLE FOR SUPPLYING 14C � A230 FOR ADDITIONAL INFORMATION. PROVIDE WALL SHEATHING AS ILLUSTRATED ABOVEcli W O2-1/2 KITCHEN/F.P.FURRING-SAME CONSTRUCTION 4'O.C.MAX.ALT.DIR. SEE EPDXY&COVE BASE NOTES ON WALL BRACE DETAILS ON THIS SHEET AND INSTALLING ALL PARTITIONS U.N.O. NOTE:G.C.TO PROVIDE INSULATION,VAPOR BARRIER, gC A230 FOR ADDITIONAL INFORMATION. GYP.BD.,TAPE,MUD,SAND,ETC.ON ALL EXTERIOR LLT AS PARTITION ABOVE.USE 2 1/2"20GA(250S125-30) WALLS IN HABIT'S SPACE FOR NEW SCHEDULED FINISHES. METAL STUDS 1 16"O.C.IN LIEU(2 STUDS CAL OUT a PARTITION TYPES w ABOVE W/2 1/2"STUD TRACKS(250T125-33) p STAINLESS NOTE:G.C.TO REPAIR/REPLACE ANY EXISTING UNDER rn W F- SCALE: 1'=1'-0' STEEL TOP BY ROOF INSULATION AFFECTED BY NEW WORK. Fs E.C. FACE OF EXISTING DEMISING WALL- ~Y W � SECURE NEW FRAMING TO EXISTING m Q STUDS-MAINTAIN PARTITION FIRE O STUD TOP TRACK 2x BRACE AT 4'-0"OC NEW PURLIN(2X RATED CONSTRUCTION -- J 600T125-33 2x WD BLOCKING BLOCKING BETWEEN =Z WITH LUS HANGER EACH ) RIPPED WIDTH OF TRUSSES SUSPENDED WASHABLEL STUD TOP TRACK SUSPENDED WASHABLE CEILING AS SCHEDULED 2x2 TUBE STEEL WALL END LL.T Z LAY-IN CEILING TILES IN 162T125-33 lAY-IN CEILING TILES IN POST IN SLEEVE @ KITCHEN AREA 48"O.C.-BOLT U m m KITCHEN AREA 14 i STAINLESS STEEL PANELS ...,.. POST SLEEVE TO GONG.SLAB W/(4) BY ERSID.FROM • ' 2x BRACE AT 4'-0"OR DINING AREA OFFICE/FOOD PREP DINING AREA UNDERSIDE OF SS TOP WITH LUS HANGER EACH I ADJACENT 3 8 BOLTS- HALLWAY FRP OVER EXISTING HALLWAY TO COVE BASE END EPDXY BOLTS INTO (4)#10x2"LONG SCREWS AT TENANT SPACE SHEATHING AND GONG, EACH BRACE EXISTING 5/8"GYP. CONTRACTOR PROVIDED 5/8"GYP.BD. EXISTING WALLBOARD 5/8"PLYWOOD OR 5/8" EXISTING 5/8"GYP. EA.SIDE 'a EXISTING / TRUSS 1 5/8"20GA @ 16"O.C. MOISTURE RESISTANT GYP. WALLBOARD 6"20GA @ 16"O.C. TRUSS L - WHERE REQUIRED �6i (60OS125-30) (162S125-30)SHIM AS 1" KITCHEN I WALL BRACE AT 4'-0"OC WALL BRACE AT 4'-0"OC WALL ACEFOR TRUE AND FLAT 24 ,2"TALL 5/6"°DRQGK® G°QK°NE 4 SOFFIT/WALL BRACE-PARALLEL 5 SOFFIT/WALL BRACE-PERPENDICULAR _ 3/8"COVED EPDXY a a WALL SURFACE BOTTOM OF WALL BASE W/CLEAR TILE BASE W/CLEAR TILE BASE W/CLEAR 12"TALL 5/8" ? SILICONE SEALANT 3/8"COVED EPDXY BASE W/ SCALE: 1° 1'-0' SCALE: 1'-T-0° SILICONE SEALANT @ TOP SILICONE SEALANT @TOP DUROCK @ @ TOP OF BASE OF BASE TOP OF CLEAR IUCOE E SEALANT @ OF BASE BOTTOM OF WALL DOUBLED 2x BRACE AT STUD SILL TRACK 2x6 BRACE AT 4'-0"OC WITH LUS HANGER EACH END 4'-0"OC WITH LUS ANCHOR METAL TRACK TO 162T125-33 STUD SILL TRACK is HANGER EACH END Cn CONCRETE SLAB W/HILTI ° - . - 600T125-33 LLJ XU TYPE FASTENERS @ EXISTING CONTINUOUS DEEP -LEG a n 18"O.C.-TYP PER ACC KEEP WALL FINISH TRUSS K L FINISH i6 GA.SLIP TRACK ESR#2269 n ° ° - FASTENERS CLEAR ASTENER CLEAR (363T200-54 OR OF TOP TRACK OF TOP TRA 60OT200-54)WITH(2) 16 DINING FURRING n PERIMETER WALL BACK OF 1 a DINING PERIMETER WALL 1 s COOK LINE WALL CONTINUOUS DEEP-LEG #10x2"LONG SCREWS AT z HOUSE 16 GA.SLIP TRACK EACH BRACE 0 (363T200-54 OR 16 6"DINING FURRING-SAME CONSTRUCTION AS PARTITION ABOVE.USE EXISTING SHELL BUILDING FRAMING. HABIT EXISTING SHELL BUILDING FRAMING. HABIT 600T200-54)WITH(2) 6"20GA(60OS125-30)METAL STUDS @ 16"O.C.IN LIEU OF STUDS 17A G.C.TO PROVIDE WALL SHEATHING AS 18A G.C.TO PROVIDE WALL SHEATHING AS #10x2"LONG SCREWS AT EXISTING O 'm (V PARTITION TYPE AS EACH BRACE PARTITION TYPE AS 16B CALL OUT ABOVE W/6"STUD TRACKS(60OT125-33) ILLUSTRATED ABOVE ILLUSTRATED ABOVE TRUSS 3 5/8"DINING FURRING-SAME CONSTRUCTION AS PARTITION ABOVE. SCHEDULED-SEE DETAIL SCHEDULED-SEE DETAIL-/ USE 3 5/8"200A(362S125-30)METAL STUDS @ 16"O.C.IN LIEU OF N O STUDS GALL OUT ABOVE W/3 5/8"STUD TRACKS PARTITION ABOVE. 6 SOFFIT/WALL TOP-PARALLEL tl SOFFIT/WALL TOP-PREPENDICULAR 2-1/2 DINING FURRING-SAME CONSTRUCTION AS PARTITION ABOVE.USE 16C 2 1/2 20GA(250S125-30)METAL STUDS @ 16"O.C.IN LIEU OF STUDS SCALE: 1'=1'-0' SCALE: 1'=1'-0' A300 CALL OUT ABOVE W/2 1/2"STUD TRACKS(25OT125-33) NOTE:IF SHROUD WALL FRAMING OR LINE OF STRUCTURE ABOVE KICKES RUCTU ERGCA TO PARALLEL PROVIDE EXISTING 1/2" GYP. BD. UP TO 6" BLOCKING BETWEEN EXISTING MEMBERS ABOVE SCHEDULED CEILING 0�;'••CAPLL :F s FOR SECURE ATTACHMENT TO EXISTING - PROVIDE (2) LAYERS OF _:�: LINGLE 1/4" HIGH FLEX GYP. BE. NOTE:ALL CURVED SOFFITS TO BE FRAMED 3 5/8" MTL. STUDS W/ STAGGER JOINTS FOR o Afl-2319 KICKERS AT 32" O.C. CURVED AREA �'''•.,• 3-5/8" MTL STUDS @ 16" O.C. (2) LAYERS 5/8"TYP "X" GYP. BE. - BUTT WITH FLEX-C-ARCH AND SHEATHED W/ ; •••' ��� W/ TYPE "X" GYP. BE. FINISHED FACES TOGETHER FOR FINISH FACES 1/4"HIGH FLEX GYP.BD.WITH 3 5/8" MTL STUDS AT 16' OC P4 EXPOSED BELOW "EYEBROW" CEILING STAGGERED JOINTS FOR A CONTINUOUS AND 5/8" GYP. BD. SHROUD SMOOTH RADIUS WITHOUT FLAT SPOTS. WALL AROUND SOFFIT SEE SCHEDULED i► CLG.HT.OWN R.C.P. 6• 2 LAYERS OF 5/8" GYP. BD ON 3 5/8" MTL STUDS AT 16" O.C. TOP - FINISH TO HEIGHT NOTED P1 FOR MENU BOARD RECESS 5/8" GYP. BD. LIGHT FIXTURES ` o r m SEE REFLECTED SOFFIT SHROUD P1 CHA.,URGERS 'GRILLED SANDWICHES* ALAI SIDES -.... CEILING PLAN m m a Fl—h FYI- o_ SUSPENDED CLG N w m Z .._ .. . .. E J N K ' 9 h B.O.C.+9'-6"A.F.F. .. .. _., .... V IN Td-Tip III @KITCHEN&EXPO N•1 7kDauW�@�r 51% 6 Pi i.. HANDMADE 'I Pi z in x�J 1 6" MTL STUD FRAMING VARIES WITH a I. - Q A400 AT 16" O.C. FOR LOCATION _ SUSPENDED MENU BOARD SEE 2/A210 SOFFIT ASSEMBLY S7.WI st'l. 595 V FIN;* 215 I' 6" FLEX-C-ARCH FRONT CHANNEL - CONTACT FLEX-ABILITY CONCEPTS 2" WIDE STAINLESS STEEL FRAME BY (866) 443-3539 h B.O.S.T-0"A.F.F. SIGNAGE COMPANY - 100 1/4" x WWW.FLEXABILITYCONCEPT.CO V 37-1/4" OUTSIDE DIMENSIONS EVEN & EQUAL DISTANCE 99 1/4" x 37 1/4" MENU BOARD h B.O.S.7'-O"A.F.F. x P7 HIGH FLEX GYP. OF iBD, - AROUND MENU BOARD CENTERED IN FRAME V STAGGER JOINTS FOR 5/8" TYPE "X" GYP. BD. 2 2" WIDE STAINLESS STEEL FRAME BY SMOOTH CURVE BULKHEAD BETWEEN KITCHEN SIGNAGE COMPANY - 99 1/4" x P1 AND EXPO 99 1/4" 37-1/4" OUTSIDE DIMENSIONS FINISH KEY NOTE - SEE FINISH 102"FINISHED zzx SCHEDULE ON SHEET A230 4'-e DIMENSION VARIES WITH D" SOFFIT ARC (ENSURE 5'-6" SIGHTLINE ABOVE FLOOR AT MAIN ENTRANCE IS ABLE TO READ THE ENTIRE MENU BOARD) a� MENU BOARD ELEVATION/SECTION al MENU BOARD SOFFIT SECTION NMI SCALE: 1--T-0- SCALE: 1'=T-0' ACT CEILING 34" 30" SECURE WATER HEATER TO 1 1/4-CEASAR STONE 1 1/4"CEASAR STONE FRP ABOVE PLATFORM PLATFORM-3/4"PLYWOOD ON WALL AT TOP AND BOTTOM WITH TOP OVER 3/4"MARINE TOP OVER 3/4"MARINE TOP OF 3-5/8"METAL STUDS® AND 1 P DIA.AXS3EE LONG PLYWOOD - PLYWOOD o 16"O.C.-BOTTOM OF STUDS ANCHOR BOLTS EACH END OR o' 0 78'A.F.F.-SHEATH T&B OF c� PER WATER HEATER / MANUFACTURER'S PLATFORM W ERR.-F.S.E.0 TO c�z PROVIDE&INSTALL S.S.CAP RECOMMENDATIONS. z J w PROVIDE BLOCKING AS REQUIRED EXTEND EPDXY FLOOR FOR HANGING ALL F.S.E.C.ITEMS FINISH OVER ENTIRE 3/4"PLYWOOD 3/4"PLYWOOD _I STAINLESS STEEL CHEMICAL WATER HEATER BASE AND w SHELF BY F.S.E.C. ONTO ADJACENT WALL WHITE MELAMINE __ ____ __ SURFACE A MIN.OF 6" DRAIN PIPES FOR THE WHITE NENMINE SHELVING, �' -FORM COVED BASE AT TEMP.&PRESSURE TYPICAL. < < SHELVING-TYPICAL s 0 HOSE BIBB -- ----- -- MOP HOLDER BY F.S.E.C. FLOOR AND WALL VALVE AND OVERFLOW o CHEMICAL DISPENSER BY F.S.E.C. PAN-ROUTE TO >a: MOP SINK&WALLS IMMEDIATELY CONCRETE BASE FOR NEAREST FLOOR DRAIN o- co WATER HEATER- WITH MIN.1"AIR GAP coec.cuae CONC.CURB m ADJACENT TO MOP SINK TO HAVE a - PROVIDE�"CHAMFERS - --- ------ - EXPDXY FLOORING SYSTEM OVER o' tO N AT ALL EXPOSED 5/8"DUROUR SUBSTRATE UP TO CORNERS-SEE PLAN BOTTOM OF PLATFORM(78 A.F.F.) - c� FOR LOCATION 4„ 10^ 10" 4" 4 BARS®24"O.C. #4 BARS®24"O.C. ", M #4 BARS®24"O.C. _ FAUCET BY FLOORING � STAGGERED-EPDXY IN STAGGERED-EPDXY IN STAGGERED-EPDXY IN EXIST SLAB W/3"EMBED 4" 4" 4" 4" 4" 4" 4^ 4" EXIST SLAB W/3"EMBED N1 BUILT-IN EPDXY FLOORING SEE PLAN EXIST SLAB W/2"EMBED MO -8 MIN P SINK W/4^WIDE&6^ J 26" 4` 4" 22" TALL GONG DAMN WRAPPED IN NOTE:APPLY CONCRETE BONDING COMPOUND TO EPDXY W/F.S.E.C.SS CAP EXISTING CONCRETE SLAB PRIOR TO CURB INSTALL p NOTE:SEE F.S.E.0 RAGS FOR BLOCKING AS REQUIRED FOR SHELVING,FAUCET&ATTACHMENTS LLI LLl al BEVERAGE o 7/ o 1 ERAGE COUNTER DETAIL aI ORDER COUNTER DETAIL alb MOPSIN K SECTION aI�TER H0EATER BASE �rn w F- M � H Y w o w m¢ O vi U Z J Q 4" 4 CONC.POUR BACK®3,000 COVER PLATE NOT TO — J PSI MIN.®28 DAY STRENGTH rn. EXCEED 1/4"ABOVE FINISH w Z FLOOR SURFACE U rn m #3 REBAR AROUND SAFE___ ____ - 12"LONG#4 TIE BARS, FINISH FLOOR SURFACE EPDXY INTO(E)SLAB w/3" ____--_-___TYP ____-___U MIN.EMBED A400 jw/ADHESIVE _eTi __ - =aT ® 6 ':ill I� ii a it - �i� = °�i. TURN EXISTING HED i� _ VAPOR BARRIER _ ° - APOR i�°^ 4a UP&PREP FOR _ ii ip VAPOR BARRIER d"r ---- ---- — di a°ii PATCH O U1 GONG.POUR BACK®3,000 12"LONG#4 TIE BARS,EPDXY w PSI MIN.®28 DAY STRENGTH INTO(E)SLAB w/3"MIN.EMBED(TYP.) BATTERY OPERATED RECESSED FLOOR SAFE w/DIGITAL KEY PAD AMSEC B1500 SUPER BATTERY OPERATED RECESSED FLOOR SAFE w/DIGITAL KEY PAD AMSEC 81500 SUPER BRUTE.SAFE TO BE INSTALLED RECESSED IN CONCRETE SLAB.G.C.TO PROVIDE BRUTE.SAFE TO BE INSTALLED RECESSED IN CONCRETE SLAB.G.C.TO PROVIDE BLOCK-OUT IN SLAB PRIOR TO INSTALL.INSTALL PER MANUFACTURERS REQUIRED BLOCK-OUT IN SLAB PRIOR TO INSTALL.INSTALL PER MANUFACTURERS REQUIRED 0 RECOMMENDATIONS.G.C.TO MAINTAIN ADA CLEARANCES AS REQUIRED. RECOMMENDATIONS.G.C.TO MAINTAIN ADA CLEARANCES AS REQUIRED. o SAFE DETAIL-PLAN SAFE DETAIL-SECTION w 13 SCALE: 11/2'-T-0' 14 SCALE: 1 1/2'-T-0- A400 ANGLE MOLDING SEISMIC CATEGORY A B&C CEILING INSTALLATION REQUIREMENTS: THE FOLLOWING ARE THE IBC CATEGORY A,B&C CODE REQUIREMENTS FOR LAY-IN STABILIZER BAR,OR OTHER j j ACOUSTICAL PANELS AND DIRECT-HUNG ACOUSTICAL TILES(COMPLIANT WITH THE SUITABLE SYSTEM,TO KEEP REQUIREMENTS OF ASCE 7-10,SECTION 13.5.6.2.1) \p\ttj111111t/1//G7°Zp��' MAIN BEAM PERIMETER COMPONENTS 8" MAX. w - _ \\5g0 AR G�o FROM SPREADING APART. `J IBC CATEGORY A,B&C MUST MEET THESE REQUIREMENTS: .......... MAIN BEAM 8 MAX. < MAIN TEE a MAIN TEE CLASSIFICATIONS-INTERMEDIATE OR HEAVY-DUN LOAD RATING a V: CAALL :Fp' m GRID AS DEFINED BY ASTM C635 ='�: LINGLE J o J MINIMUM INTERSECTION STRENGTH OF MAIN TEE SPLICES AND CROSS-TEE o AB-2919 : MIN.3 8"AT ALL WALLS a INTERSECTIONS OF 60 LBS / 1 ±10 MAXMA 1 MAX CROSS TEE cy - VERTICAL HANGER WIRE ��•" STABILIZER BAR, �6 12 GA.VERTICAL 6 < a -MINIMUM OF 12-GAUGE 12 GA. VERTICAL '< -SPACED AT A MAXIMUM OF 48 INCHES 4'-0'O.C. OR OTHER MIN.7 8 HANGER WIRE HANGER WIRE w w ( ) I••• SUITABLE SYSTEM, / ANGLE MOLDING F 4 0 "' -MUST BEND SHARPLY AND WRAPPED WITH 3 TIGHT TURNS WITHIN 3 TO KEEP PERIMETER g^MAX. STABILIZER BAR MAX UM INCHES AT THE GRID AND CEILING/SUPPORT MEMBER ABOVE COMPONENTS FROM STABILIZER BAR, o MAIN TEE o MIN. 3/8" STABILIZER BAR -MAY BE A MAXIMUM OF 1 IN 6 OUT OF PLUMB SPREADING APART. OR OTHER SUITABLE MIN. 3/8" z fn z SYSTEM,TO KEEP ¢ cn a -SHALL NOT ATTACH TO NOR BEND AROUND INTERFERING EQUIPMENT TRAPEZES MUST BE USED TO AVOID SUCH OBSTACLES PERIMETER COMPONENTS 3 8' - / 9 XIMUM _ m - PERIMETER CLOSURE(MOLDING)WIDTH-MINIMUM 7/8"GRID o FROM SPREADING APART. - c x CROSS TEE CROSS TEE - 3/8 INCH MINIMUM GRID END WALL CLEARANCE ON ALL SIDES a o� z _-- -- ------ ____-- z - ALL GRID ENDS ON ALL WALLS MUST BE FREE TO MOVE �^ PERIMETER VERTICAL HANGER WIRES NOT MORE THAN 8"FROM WALL CROSS TEE 7/8" •0, UNRESTRAINED GRID TEES AT ALL WALLS - ALL PERIMETER GRID ENDS MUST BE TIED TOGETHER TO PREVENT SPREADING m m a MIN.3/8'AT ALL WALLS '•. PARTITION ATTACHMENT-BRACING SHALL BE INDEPENDENT OF CEILING X 12-GAUGE HANGER WIRE - "UNATTACHED" ° 7/8 7/8" SUPPORT OR BRACING 19 -m w m MIN.7/8" MIN. MIN. ---STABILIZER BAR - SPRINKLERS AND OTHER PENETRATIONS MUST HAVE MINIMUM 3/8 INCH '^ CLEARANCE ON ALL SIDES CHANGES IN CEILING PLANE MUST HAVE POSITIVE BRACING 3 w m RESTRAINED PERIMETER RESTRAINED PERIMETER LI SUSPENDED CEILINGS MAYBE SUBJECT TO SPECIAL INSPECTION _ al SEISMIC REFLECTED CEILING PLAN a� CEILING DETAILS AND NOTES a CROSS TEE a MAIN4 SCALE. N.T.S. LIGHT FIXTURE ATTACHMENT UNLESREQUIS INDEPENDENTLY LIGHT FIXTURE(ALL TYPES)MECHANICALLY ATTACHED TO GRID NEC 410-16 (TWO PER FIXTURE UNLESS INDEPENDENTLY SUPPORTED) SCALE: N.T.S. SCALE: NTS SCALE: NTS SURFACE-MOUNTED FIXTURES SHALL BE POSITIVELY CLAMPED TO THE GRID - PENDANT-HUNG FIXTURES DIRECTLY SUPPORTED FROM STRUCTURE WITH STEEL STUD POST,MIN 16 9-GAUGE WIRE(OR APPROVED ALTERNATIVE) GA.,AT 48"O.C., LIGHT FIXTURES LESS THAN 10 LBS REQUIRE ONE 12-GAUGE WIRE TO STEEL STUD STRUCTURE(MAY BE SLACK) (4"MIN.STUD SIZE) #10 S.M.S.,TYP. LIGHT FIXTURES FROM 10 TO 56 LBS-TWO 12-GAUGE WIRES FROM STEEL STUD #12 ON MAIN RUNNER 3"MAX (2)#12 FIXTURE SUPPORT WIRE HOUSING TO STRUCTURE(MAY BE SLACK) WITHIN 3"OF 4 CORNERS PER FIXTURE TO STUCT ABOVE.#9 LIGHT FIXTURES OVER 56 LBS MUST BE SUPPORTED DIRECTLY TO STRUCTURE 2-#10 S.M.S. WIRE TO BE USED FOR FIXTURE BY APPROVED HANGERS "HILTI".145 DIA. STEEL STUDS WELDED OF LIGHT FIXTURE WEIGHING S6L6 OR MORE OR - RIGID CONDUIT IS NOT PERMITTED FOR ATACHMENT OF FIXTURES X-DNI37P8 TOGETHER OR 5-12 y PENDAM HUNG F0(iURE.WIRE MAY POWDER SCREWS AT 8"O.C. HAVE SLACK. MECHANICAL SERVICE APPLICATIONS REQUIREMENTS: DRIVEN PINS ALTERNATE DIRECTION. - FLEXIBLY MOUNTED MECHANICAL ITEMS LESS THAN OR EQUAL TO 20 LBS 0 48"O.C. 1" O BOTTOM CHORD OF MUST BE POSITIVELY ATTACHED TO GRID EXITING TRUSS MECHANICAL ITEMS FROM 20 TO 56 LBS MUST BE POSITIVELY ATTACHED TO LIGHT FIXTURE GRID AND HAVE TWO 12-GAUGE WIRES TO STRUCTURE(MAY BE SLACK) - MECHANICAL ITEMS OVER 56 LBS REQUIRE DIRECT SUPPORT TO STRUCTURE 5"WIDE�/"STL. PLATE W/3/8" }� O O GENERAL NOTES: EXPANSION BOLTS \'� k ��y O O 2-#8 X 1 1/4" y� STUD PIECE TO MATCH DECK SCREWS SIZE AND GAUGE OF WALL H8 x)/4"SHEET 1. ALL CEILING DETAILS ON THIS SHEEP ARE SIMILAR FOR INSTALLATION OF C O MMETAL SCREW TECTUM CEILING PANELS ONTO SUSPENDED GYP.BD.CEILING GRID SYSTEM. 0 (ICC-ESR-1222&ICC-ERS-1112-CEILING PANELS) 5 O COPE FLANGES OF CROSS STUD 2. ALL SUSPENDED CEILING SYSTEMS SHALL BE INTERMEDIATE OR HEAVY DUTY NON-LOAD BEARING WALL SEISMIC CLIP T-BAR GRID SYSTEM.(ICC-ESR-1308)ARMSTRONG DRYWALL SUSPENSION STEEL STUD WELDED O O CUT TRACKS AND TEE SYSTEMS 1 #10 SMS EACH TO PLATE O INTERLOCK SPLICE 3. FOR ALL CEILING AREAS EXCEEDING 1,000 SF HORIZONTAL RESTRAINT OF THE 1 - #10 S.M.S. NUMBER OF SUPPORT WIRES PER FIXTURE:LESS THAN 10 LBS ONE WIRE TO SIDE OF STUD e' ir' 0 STRUCTURE(MAY BE SLACK)10 TO 56 LBS TWO WIRES FROM HOUSING TO CEILING TO THE STRUCTURAL SYSTEMS SHALL BE PROVIDED. ii 4. SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE AN OVERSIZE RING, ii STRUCTURE(MAY BE SLACK)MORE THAN 56 LBS SUPPORTED DIRECTLY TO SLEEVE,OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE STEEL RUNNER TRACK OR I STRUCTURE BY APPROVED HANGERS MOVEMENT OF AT LEAST 3/8 INCH IN ALL HORIZONTAL CONDMONS ilk I SLOTED STEEL TOP TRACK ��.I, ' STEEL RUNNER TRACK 5. EACH SUSPENDED CEILING AREA SHALL BE PROVIDED WITH CLOSURE ANGLES AT TOP OF WALL CONDITION INTERLOCK SPLICE NOT LESS THAN 7/NA IN WIDTH. FRAMING AT LOW WALL INTERLOCK SPLICE MECHANICAL ATTACHMENT OF IN SHALLRBEFREE ORTHOGONAL ON DIMENSION,ALL °`THE CEILING aBOTTOM TRACK a BRACING POST a AT SLIP TRACK a AT SLIP TRACK al LIGHT FIXTURE TO CEILING GRID SHALL RESTUPON"A`ND"BEEFREE TO SFDCLEARANCE OS RE"ANC E"A"° SCALE: NITS SCALE; NTS SCALE: NTS SCALE: NTS SCALE: NTS a^ Varies 1 3 5/8" to 8" 4" #10 S.M.S.,typ ___—____1 1^ f�y P.) NUMBER OF SUPPORT WIRES PER FIXTURE: 1/2" LESS THAN 10 LBS ONE WIRE TO STRUCTURE (MAY BE SLACK) II '� I\\ ~ -___�O 10 TO 56 MORE THAN LBS TWO WIRES FROM HOUSING TO STRUCTURE (MAY BE SLACK) 11 i��i O O ______ MORE THAN 56 LBS SUPPORTED DIRECTLY TO STRUCTURE BY APPROVED HANG RS 2 1/4" A o O GAP 1/a"MAXIMUM T P. � i � MAY BE SLACK J METAL STUD � SIDE VIEW � o SUP TRACK LIGHT FIXTURE LIGHT FIXTURE MOUNTING Lu BRACKET w CIO VIEW Varies #12 WIRE TYP. STUD WALL 16 GA.X 4"LONG u ° CROSS TEE HEIGHT BETWEEN SUPPORT INTERIOR METAL STUD SIZE AND SPACING(5 ESE) W HEAD OF WALL ISOMETRIC WIDTH VARIES STUD SHOE OR FLAT PLATE �n Q. o TO FIT INSIDE TRAC UP K ATTACH ch TO WEB WITH(4)#10 S.M.S. TO 20'-0" 1 3/8"X 3 5/8"X 20 GA®16"O.C. W H � UP TO 26'-0" 1 3/8"X 4"X 16 GA 0 16"O.C. Y LL in a SLIP TRACK DETAILS UP TO 30'-0" 1 3/8"X 6"X 20 GA®16"O.C. 10 SCALE N.T.S.T.S 0 SUSPENDED BRACING LENGTH SIZE SCREWS =Z J CEILING PANEL — OPTIONAL SLIP SEISMIC ATTACHMENT OR UNDER 3 5/8"X 25 GA 3-#0 SMS EACH END 6'-1"TO 12'-0" 4"X 20 GA 3-#10 S.M.S EACH END 11 TRACK SPLICE 12 IFOR CAN LIGHT FIXTURE LIGHT FIXTURE 12'-1"TO 16' 6"X 20 GA. 3-#10 S.M.S EACH END SCALE; NTS SCALE: NTS METAL STUDS AND FASTENER INFORMATION METAL STUDS: ALL PREFABRICATED METAL STUDS,JOIST TRACK SHALL CONFORM TO THE METAL STUD MANUFACTURERS ASSOCIATION TECHINCAL HANDBOOK ESR-3064P AND TO BE LISTED BY APPROVED LISTING AGENCY SUCH AS ICBO OR ICC. BE gPS SCREW FASTENERS FOR LIGHT GAUGE METAL STUDS: METAL STUD,TRACK,AND JOIST ATTACHMENTS SHALL CONFORM TO THE METAL STUD MANUFACTURERS ASSOCIATION TECHNICAL HANDBOOK ER4943P WHEN NOT SHOWN - OR DETAILED OR SPECIFIED WITH IN THESE PROJECT DRAWINGS OR SPECIFICATIONS. THE FOLLOWING MINIMUMS SHALL APPLY IF NOT COVERED ABOVE OR SHOWN IN THESE N DRAWINGS OR DETAILS: J - ALL STUD TO TRACK:MIN.1 -#10 S.M.S.FASTNED EACH SIDE. - STUD OVERLAPS WEB/WEB:MIN.2-#10 S.M.S.SPACED MIN.2"THIRD FACE. ALL MEMBER CROSSINGS(WEB TO FLANGE,ETC.):2-#10 S.M.S.THRU FACE. w -EXTENDED WEB OR FLANGE SCREWING TABS:2-#10 0 WHERE SHOWN IN THESE PLANS METAL TO METAL SCREW ATTACHMENTS SHALL BE MADE WITH APPROVED FASTNERS LISTED BELOW: 0 o � Lu GENERAL METAL STUD FRAMING FASTENERS:"GRABBER OR SUPERDRIVE" r AS LISTED IN ICC-ESR-1271 m o (V METAL STUD FRAMING FASTENERS-HEAVY SERVICE:"HWH 12-14 X 1" zs Z AS LISTED IN ICC-ESR-2196 N A410 immommomi GRAPHICS 81CFEWLE Ems ARTWORK AND 1 1 1 1 10 MENU BOARD 99.25" 37,25" 2"STAINLESS STEEL SIGNAGE LOCATIONS TIERSE'S NO SUBSTITUTE FOR QUALITY SEE SHOP DWGS AR-2319 (By IGNAGE CONTRACTOR) -- KEYNOTE SEE ABOVE ARTWORK SEE SCHEDULE -- DIGITAL(By 111NAIE CONTRACTOR) ORDER PICK-UP SEE SHOP DWGS FINISHES SEE A230 (By SIGNAGE CONTRACTOR) DISPLAY BOAR, MENNEN `J 1•CI••1 ADOWBOX WOOD _ —�:I. IJ ./ •/ 11 1 '1• 1 ■L7-..�-� ■ CUSTOMDWGS (BY SIGNAGE CONTRACTOR) LIFEGUARD TOWER 4"SQUARE WOOD ' O II I I� I� , ..1 11 1 1• 11• /1.1 ■I■■y®�.■� I, O _IL,!I-L �I��I���_I�I_���rl���_I_��_I_�■ 1 1 . 1 1 1 • SANTA BARBARA STREET SIGN 4"SQUARE WOOD 4"SQUARE WOOD SANTA BARBARA HARBOR SCENE ALONG THE WATER 4"SQUARE WOOD )k SOUTHERN COASTLINE 4"SQUARE WOOD ONI'dflOdEl N`]I53Q 319N1-I RED SURFBOARD 4"SQUARE WOOD BOOTH AND TABLES SLATING BY OTHERS. ' ® SQUARE111 . ® ® WAINSCOT:1 1 1 G 11 1'O -C ■■■■■■■■ 4"SQUARE WOOD1— p ■■■■■■■■ CABRILLO AVENUE GLOW 4" ! 111Ulm .1NN BOARD-SEE DTL I/A400. MENEM TRASH BY MILLWORK VENDOR ■■■■■■■■ NoT O ■ © I' O SOFFITCEILING 1 1 1 ■ppi.m�� PROVIDE OCCUPANCY' ON GYPSUM CONSPICUOUS LOCATION NEAR THE MAIN EXIT OR EXIT • • • • 11 CONTRACTOR 1 INSTALL TRIX I- SEE DETAIL r— J'Ulm ® _O � 1 11 1 ■:Y:I:JI ■■■■■■■■ m ■■■■■■■■ — E? ■■■■■■■■ ■ENEMY■■ m m ==— m ' ® — - ■■■■■■■■ IlI IIII I I1I 0 0 --==== o o = ■■■■■■■■ MEN �r���r���r��I�� -� ��■ MKIMEMEME ■o■A■■A■ • . • © 1 ., ■M■■■■Eq■ _ =� ■t ■■■■I ■ I _ - ■..■CAA■C�■ ■ _: MENEM Ell 1 1 1 1 1•EXTERIORNEEDED I 151�01� A CARILL LINGLE o -231 NEW BUILDING SIGNAGE NEW BUILDING SIGNAGE INSTALLED BY SIGNAGE VENDOR INSTALLED BY SIGNAGE VENDOR NEW BUILDING SIGNAGE INSTALLED BY SIGNAGE VENDOR ma ll L IF————— p, )o L—————- J FROSTED SPANDREL GLASS LFROSTED SPANDREL GLASS GLAZING BY LANDLORD ENSURE THAT STREET ADDRESS NUMBERS ARE CLEARLY VISIBLE FROM J LJ�VAf[6NEIL CLASS PANELS GLAZING BY LANDLORD EAST ELEVATION THE STREET-FIELD VERIFY THAT NUMBERS AREA MINIMUM OF 6" SOUTH E BY LANDLORD SCALE: 3/16--T-0- HIGH AND HIGHLY CONTRASTING TO THE WALL SURFACE THEY ARE MOUNTED ON SCALE: 3/16'-T-0' NOTE: ALL EXTERIOR SIGNAGE UNDER SEPARATE PERMIT. C.C. TO COORDINATE SIGNAGE ANCHORAGE REQUIREMENTS WITH SIGNAGE VENDOR. d Signage not approved. Separate permit required for all signage. nor, Planning and zoni M& HX/ \7 MEL-- ILI Lu —OPAQUE SPANDREL GLASS PANELS ZE c� �f BY LANDLORD rn LU F- Cl> 1_Y LL o LU 0 NOTE 1:REMOVE ALL EXISTING FLASHING,LEADS,ETC.PIPE SURFACE MUST BE FREE OF ALL RUST, E�WEST -LGOTEASE,INSULATION,ETC. =A -J LU:5-- n _j NOTE 2:POURABLE SEALER MOUNDED TO SHED WATER(MIN DEPTH OF 2"),REMAINDER OF POCKET M-C14- -4mc, MAY BE FILLED WITH A NON-SHRINKING GROUT. NOTE 3 DO NOT USE OVER EXISTING PENETRATION POCKETS -————————- NOTE 4:DO NOT USE WHEN SERVICE LINE TEMP EXCEEDS 180'F. 6x6 ADA ACCESSIBILITY STICKER 18"W.x 13"H.'THE HABIT NOTE 5:IF FIELD MEMBRANE IS CUT FOR INSTALLATION,THE MEMBRANE MUST BE REPAIRED WITH NOTE PERIMETER FASTENING OF THE DECK MEMBRANE WILL NOTE 1 INSTALL ONE VENT FOR EVERY 1,000 SQUARE FEET OF BURGER GRILL"VINYL LOGO TACTILE EXIT SIGNAGE BEYOND PROVIDE AND COMPATIBLE ROOF MEMBRANE PRIOR TO INSTALLATION OF THE PENETRATION POCKET. E FASTENING PATTERN AS THE FIELD NOTE 1:IF A LEAD FLASHING IS PRESENT ON THE PIPE,IT MUST DURO-LAST DECK MEMBRANE. VENTS SHALL BE EVENLY SPACED (INTERIOR FACE OF GLASS SIGNAGE VENDOR C BE THE SAME BE REMOVED BEFORE A DURO-LAS STACK FLASHING INSTALLED BY -bit MEMBRANE,MAX. 18-INCHES ON CENTER,AND NO LESS DOOR I IS INSTALLED. BETWEEN ROWS OF FASTENING TABS ACROSS THE ROOF. PEN Na NOTE 6:MEMBRANE MUST BE INSTALLED WITHIN 1/2"OF PENETRATION. THAN ONE FASTENER PER SIDE. 1 BURGER SPILL 1 PS NOTE:PERIMETER FASTENING OF THE DECK MEMBRANE WILL NOTE 2:MEMBRANE ATTACHMENT AROUND THE PENETRATION WILL NOTE 2 CUT A 7-INCH HOLE THROUGH DURO-LAST MEMBRANE T BE THE SAME FASTENING PATTERN AS THE FIELD BE THE SAME AS THE DECK MEMBRANE,MAX. 18-INCHES ON FOR VENT INSTALLATION AND INSTALL FEET UNDER MEMBRANE. y/_ NOTE 7:SEALANT REQUIRED ON PENETRATIONS AND MEMBRANE INSIDE OF PENETRATION POCKET. SHEET MTL CAP MEMBRANE,MAX. 18-INCHES ON CENTER,AND NO LESS OT POURABLE SEALER 6" P.T.5/8"PLYWOOD THAN ONE FASTENER PER SIDE. CENTER,AND A MINIMUM ONE PLATE/FASTENER PER FLASHING. DO N FASTEN VENT TO DECK. C/) CUT PVC PIPE P.T.26 0 16"O.C. DURO-LAST TWO-WAY VENT WITH ;z PITCH POCKET MIN.' VIN.' MIN. RECTANGULAR `ENL!f.Nj TYPICAL VENT PIPE STAINLESS STEEL BAND PREFABRICATED SKIRT 0 GALVANIZED STAINLESS POSITIONED -INCH . . . . . . SEALANT NAIL 6"D.C. STEEL BAND FROM THE TOP OF BONDING ADHESIVE THE STACK FLASHING z ROOF MEMBRANE > T DURO-LAST T DURO-LAST FACTORY WELDED _T INSULATION PREFABRICATED MIN. PREFABRICATED 8" PREFABRICATED VENT SKIRT LL1 GALVANIZED U STACK FLASHINGVENT O.C. ORB CUSTOM CURB MIN. NAIL 6' FLASHING �7 /J/F_ D ENTRY DOORS,SPECD LINE ♦HABIT BURGER GRILL, '%—————————-- ROOF DECK-----' DECK DECK BY HABIT BURGER OPEN/CLOSED&HOURS" NON-SHRINK GROUT DECK DECK NOTE.HOURS SIGNAGE TO ALWAYS SIGNAGE-PROVIDED AND BE ON OPPOSITE SIDE OF DOOR INSTALLED BY SIGNAGE VENDOR PENETRATION FROM TRASH RECEPTACI E >< RECTANGULAR ROUND TWO-WAY 'KI ii I -I-- LL UU a�PITCH tPENETRATION PENETRATION BREATHER VENT aISTYPICAL aICONDENSER I SCALE: N.T.S. aj SCALE: N.T.S. aj SCALE: N.T.S. A51 0 4 2 3 BUILDING CODES AND STANDARDS USED FOR DESIGN /FF�, 4F! Q iFF� Q v 1. INTERNATIONAL BUILDING CODE 2015 EDITION ��/ �'+ 25'-4" ��/ q ��/ �'+ 25'-4" =a *DOL " ' " NG 2-1/2"DIATHRU-BOLT 2 s s s OCCUPANCY CATEGORY:II +s �S S DESIGN LOADS w/HARDENED STEEL WASHER /r� .� /rS .� �S .� m c c (E)(3)2x8-FV z 1. DESIGN LOADS E)(3)-1 3/4�I"x11 7/8"-LVL-FV _ _ _ _ _ _ _ _ _ F ROOF LIVE/SNOW LOAD: 30 psf ROOF DEAD LOAD: 15 psf I J I I J J I I 1 I I I I I I I I II I k I II �I _ 2. SEISMIC LOAD DESIGN CRITERIA 1 1 /2" CONDENSING UNIT PLATFORM PER MECH DRAWINGS. i SEISMIC IMPORTANCE FACTOR,I: 1.0 MASC WEIG HT EA COND�NSEA=222 LBS. c w SITE CLASS: D NUT 2x6 BLKG BTWN JOISTS SPECTRAL RESPONSE ACCELERATION: Ss=0.210g, S1=0.081 g R ROD w/SIMPSON LUS26 HGR (E)PRE-FABRICATED WOOD TRUSSES @ 24"oc-FVJ R w SPECTRAL RESPONSE COEFFICIENTS: Sds=0.224g, Sd1=0.129g EA END SEISMIC DESIGN CATEGORY: B A HANGER ROD DETAIL w/WOOD BLOCKING I I I I I I I I I I II I I II EXISTING CONSTRUCTION NOTES s oo N.T.S. 1. ALL DIMENSIONS AND ELEVATIONS TO EXISTING CONSTRUCTION ARE FOR REFERENCE T1 T1 T1 T1 T1 T1 T1 T1 T1 T1 T1 I I I I I I I I I II I I II I _ P r ONLY. FIELD VERIFY DIMENSIONS AND ELEVATIONS PRIOR TO PREPARING SHOP 1 w Tia z DRAWINGS,FABRICATING MEMBERS(STRUCTURAL ITEMS),AND INSTALLATION. I I I I IRTU-1I 2. ALL HOLES THROUGH EXISTING CONSTRUCTION SHALL BE CORE DRILLED OR SAWCUT. + „ w DO NOT CUT ANY REINFORCING STEEL WHILE DRILLING INTO EXISTING CONCRETE. DO i� I' 1,619# HOOD NOT TORCH CUT. I I�z � o -1 I I I I I I I I I I I I II I I II I w m_ M zi�� `� � �< w 3. PRIOR TO SUBMITTING ANY SHOP DRAWINGS,PROVIDE CERTIFICATION FROM LAND 1,562# _ W Z IC a 4 3 SURVEYOR REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED THAT (E)TRUSS PER PLAN I I I I I I I I II I I II I DIMENSIONS BETWEEN NEW CONSTRUCTION AND EXISTING CONSTRUCTION HAVE BEEN SURVEYED AND FORWARDED TO SHOP DRAWING DETAILERS. 4. NOTIFY STRUCTURAL ENGINEER IMMEDIATELY OF ANY DISCREPANCIES BETWEEN 4 2x6 BLKG-TYP EXISTING CONDITIONS AND STRUCTURAL DRAWINGS. N " 10d NAILS @ 6"oc @ 5. FOR ALL EXISTING CONSTRUCTION:DUE TO LIMITED OBSERVATION,OR NOT BEING ABLE PERIMETER OF OPENING(E) TO VISIT THE EXISTING BUILDING DURING THE PREPARATION OF THESE DOCUMENTS, EF PLYWOOD DECK TO BLKG + FEDIFICA CASE ENGINEERING HAS ASSUMED THE EXISTING STRUCTURE IS IN LIKE-NEW 246#' ' CONDITION WITH NO CORROSION,DETERIORATION,OR DAMAGE AND WAS CONSTRUCTED x (E)6x8 POST z PER ANY ORIGINAL CONSTRUCTION DOCUMENTS PROVIDED(IF ANY EXIST). CONTRACTOR SIMPSON LUS26 HGR,TYP OF(8) T2 T2 T2 T2 T2 T2 SHALL VERIFY THESE ASSUMPTIONS TO THE BEST OF THEIR ABILITY AND NOTIFY THE FV + I I + I I I I I I I I I I I I II I I II ENGINEER OF ANY CONCERNS,ISSUES OR DISCREPANCIES. rtm 2x6 BLKG(OMIT WHEN OPNG IS N 7 WITHIN 2"OF PURLIN OR TRUSS) fo I I z EF-2, z + I\ I I I I I I I I I I (E)f S 6x+1/4+=FR GENERAL STRUCTURAL NOTES _ + MAU- 1. THIS DRAWING SET IS TO BE VIEWED AS A WHOLE AND COORDINATED WITH �I z 246#' MAU- ARCHITECTURAL,MECHANICAL,AND OTHER DISCIPLINES. ALL WORK PERTAINING TO A TRUSS STRUT PER a TYP DETAIL > m I M I M I-I I I-I I I I I(E)64"x27'IGLB-�V II SPECIFIC CONTRACTOR MAYOR MAY NOT BE SHOWN ON SPECIFIC DRAWING SECTIONS. ( B }— - -� -IT IS EACH SUBCONTRACTOR'S RESPONSIBILITY TO PREPARE HIS BID FROM A COMPLETE TYP BLOCKING @ ROOF OPENING N ^ ++ I (E, 3/4"x2b"GLBI_FV I I I I III I I 1 I _�, SET OF PLANS. V xI o „ + O HSS x6x1/ COL;FV slop N.T.S. v _N 2. THE CONTRACTOR SHALL FOLLOW WRITTEN DIMENSIONS ONLY. DO NOT SCALE w o + < �_ DRAWINGS. DIMENSIONS NOT SHOWN ON PLAN TO BE COORDINATED WITHco I I I I I Pr I D I I I Q I + I I I I I I I I T1 T1 T1 T1 I ,— ARCHITECTURAL PLANS. w 3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL (1 6x8 LOST I I I + x I I a I I I I I I I I AND SHALL APPLY AT ANY SIMILAR SITUATION ELSEWHERE ON THE JOB,EXCEPT WHERE V A DIFFERENT DETAIL OR SECTION IS SHOWN. r + RTU-2 4. THE STRUCTURE SHALL BE ADEQUATELY BRACED AND SHORED DURING ERECTION I I I I I ' 1Dz 4HOC�D-2 I I I I I I I I 1t�� EF 3, 1, 56# AGAINST WIND AND ERECTION LOADS. STRUCTURAL MEMBERS ARE DESIGNED FOR 194# —— "IN-PLACE"LOADS ONLY. ATTACHMENT PER MECH EQUIPMENT I I I I I I I I I I I I I I I 5. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL DRAWINGS CONTRACTOR BY OTHERS PRIOR TO FABRICATION,FORMING,OR PLACEMENT OF MATERIALS.GENERAL I I I I I I CONTRACTOR SHALL REPORT DISCREPANCIES IMMEDIATLY TO OWNER AND SHALL PROCEED WITH CONSTRUCTION ONLY AFTER DISCREPANCIES HAVE BEEN RESOLVE CURB BY OTHERS n 6. THE GENERAL CONTRACTOR SHALL VERIFY ALL OPENING SIZES AND LOCATIONS WITH #10 WOOD SCREW THE RESPECTIVE CONTRACTORS. 3 PER SIDE MIN (E)SHEATHING 7. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY OF ANY I I I I I I I DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS AND ACTUAL FIELD FJ M CONDITIONS. 'a F 8. SEE ARCHITECTURAL PLANS FOR ADDITIONAL DETAILS AND INFORMATION. y+�+6�c'LL I I I I I I I I I I I I I I I I I tp �q 9. ALL ELEVATIONS GIVEN ARE REFERENCED TO FINISHED FLOOR ELEVATIONS AT 0'-0", UNLESS SHOWN AS USGS ELEVATIONS. 10. WHERE GENERAL NOTES OR TYPICAL DETAILS CONTRADICT INFORMATION PROVIDED IN PER PLAN WHERE THERE IS NOT AN(E) \ �I (E)PRE-FABRICATED WOOD TRUSSES @ 24"oc-FV; BUILDING SECTIONS,THE BUILDING SECTIONS TAKE PRECEDENCE. TRUSS STRUT JST BELOW CURB WITHIN 2" 11. WEIGHTS SHOWN ON DRAWING INCLUDE WEIGHTS OF UNIT,CURB,AND ALL PER TYP DETAIL OF CURB CENTERLINE xI I I I I I I I I I I ACCESSORIES.DO NOT PLACE UNIT WHEN OPERATING WEIGHT EXCEEDS THAT vi INDICATED.NOTIFY STRUCTURAL ENGINEER IF MORE THAN 2"FROM(E)JST 2x6 w/SIMPSON LUS26-2 I I I III I I I I 12. EQUIPMENT WEIGHING LESS THAN 40LBS NOT SHOWN ON PLAN.SEE MECHANICAL HGR @ EA END y o DRAWINGS INSTALL 2x6 BLKG AS SHOWN w ch 13. VERIFY LOCATIONS OF ALL MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS I I I I I I I c ROOF FRAMING SECTION w 14. ALL REINFORCEMENT AND SUBFRAMING INDICATED ON PLAN SHALL BE INSTALLED PRIOR sioo N.T.S. TO PLACING EQUIPMENT (E) 1/8"x1I2"GLd-FV I (E�5 1/8'�l2"Gl[B-FV I I Lu o (E)(3)1 3/4"x11 7/8"LVL-FV - rnw SUM 4. wr — Z — ----------- — — — — PARTIAL EXISTING ROOF FRAMING PLAN ~ " OUTLINE OF CURBS Soo 1/2"dia THRU BOLT SCALE:1/4"=1'-0" z m CONNECTION PER 2x6 BLKG AS REQD TO 2x BLKG B/S100(TYP)---' NOTE: N FRAME OPNGS O DETAIL APPLIES TO ALL CONCENTRATED LOADS WHICH O PER PLAN WHERE DIM"A"IS EQUAL TO OR EXCEED 100#AND ARE LOCATED MORE THAN 2"OFF o w J x 3/8"dia THREADED GREATER THAN 4"FIELD PANEL POINTS(TOP OR BOTTOM CHORDS) o o Q c MAN a ROD(TYP) INSTALL 2x8 ON EA SIDE OF o P1000 STRUT RypO° o JOIST AS SHOWN W m Pl TYPICAL TRUSS STRUT DETAIL y o 2x6 BLKG UNDER CURB c PANEL POINT A', LOAD v A (E)TOP&BOTTOM CHORD 06 10d NAILS @ 6"oc @ j v 6-16d NAILS,TYP TOP&BOTTOM,EA.SIDE LLu PERIMETER OF OPENING (E)PLYWOOD DECK TO BLKG i Z P1000T STIFFENER,MIN HOOD PER (E)METAL ROD WEB 0 LENGTH TO BE 8"SHORTER z J THAN THREADED ROD 2x8 DFL NO.2 OR BETTER J --- --------- ------ --- STRUT EA SIDE Q 2x6 UNDER CURB x TRUSS STRUT PER UNISTRUT P1843W FITTING EA END "A" A x W W TYP DETAIL OF STRUT w/1/2"dia BOLTS AND HANGING LOAD A-A z w z P1010 CHANNEL NUTS TYP ELEVATION VIEW TRUSS PER PLAN N W D TYP ROOF TOP EQUIPMENT SUPPORT&OPNG DETAIL E TYP SEISMIC BRACING DETAIL FOR HOOD F TYPICAL TRUSS STRUT DETAIL Y N siao N.T.S. siao N.T.S. s129 N.T.S. S 100 A g (E)TRUSS TOP z CHORD c x d Ao. c_ ao c 2x4 WEB REINF,ALT - SIDE WHERE POSSIBLE U LL i (E)TRUSS WEB MEMBER N E F 1l1 0 [] maz A mo mPm [(E)TRUSS BOT 0 w 11'-0"MIN 11'-0"MIN CHORD Q O A-A WEB REINFORCEMENT TO PANEL POINT WEB REINFORCEMENT EXTEND TO PANEL POINT w m wz zx a 4 3 `S: TRUSS REINF. DETAIL-T1 - N.T.S. (E)TRUSS TOP CHORD Y Y . A 2x4 WEB REINF,ALT SIDE WHERE POSSIBLE (E)TRUSS WEB MEMBER memo tt (E)TRUSS BOT A A_A CHORD 5'-0"MIN W WEB REINFORCEMENT TO PANEL POINT TRUSS REINF. DETAIL-T2 p s�oo N.T.S. m ON I. ,EI , (P �q N P J Lu � o � u) ILL M Lu W co M W W p LLI m : vj J L.j Z Z_ U � H �a ti z z a� 2 U �N U a�� o cn N uj Nrn S200 TYPE I EXHAUST HOOD SCHEMATIC ENVIRONMENTAL HEALTH NOTES SHEET INDEX SHEET NO, DESCRIPTION FSOO COVER SHEET I A CONCRETE SLAB 15 PROVIDED FOR TRASH,GARBAGE,AND GREASE CONTAINER 21 ALL PLUMBING ELECTRICAL AND GAS LINES SHALL BE CONGEALED WITHIN THE FS200 EQUIPMENT PLAN AND LIST IF WALLS ENCLOSE AREA,THE INTERIOR WALL SUIR-A,CESWILL BE SMOOTH,SEALED BUILDING STRUCTURE TO AS GREAT AN EXTENT AS POSSIBLE.ALL EXPOSED MAKE-UP AIR FAN BY KEC. 0'-0'MR EXHAUST DISCHARGE AND WASHABLE(EG.,PLASTERED SMOOTH AND PAINTED,ETC),, CONDUITS,PLUMBING,ETC.SHALL BE INSTALLED AT LEAST 6"OFF FLOOR AND P5205 EQUIPMENT UTILITY SCHEDULE SEE EXACTMECHANICALCOWL LIRATIONS VERIFY WITH LOCAL CARE BE LEVELED WITH 3/4"FROM WALLS USING STANDOFF BRACKETS. F5210 PLUMBING PLAN FOR EXACT COpFk#NR,ATION PARAPET WALL 2 ALL FOOD-EQUIVALENT TO TEDSANITATION AND UT STAND R DS ESBLUSH EQUIPMENT SHALL MEET OR BE AND SPECIFICATIONS. EQUIVALENT TO SANITATION STANDARDS ESTABLISHED BY AN AMERICAN 22 CONDUITS,PLUMBING OR PIPING CANNOT BE INSTALLED ACROSS ANY AISLE WAY, F5220 ELECTRICAL PLAN NATIONAL STANDARDS INSTITUTE(ANSI)ACCREDITED PROGRAM, TRAFFIC AREA OR DOOR OPENING. F5230 BUILDING CONDITION PLAN:WALL-BACKING,HOOD-SUPPORT AND CURB 3 ALL FLOOR MOUNTED EQUIPMENT WILL BE INSTALLED ON MINIMUM 6'SANITARY 23 MULTIPLE RUNS OR CLUSTERS OF CONDUIT OR PIPELINES SHALL BE FURRED IN P5500 KITCHEN EQUIPMENT ELEVATIONS AND KEY PLAN EXHAUST FAN BY KEL. LEGS,CASTORS OR COMPLETELY SEALED IN POSITION ON A 4'HIGH CURB WITH OR ENCASED IN AN APPROVED SEALED ENCLOSURE. ��� ��� CONTINUOUSLY COVERED BASE.COUNTERTOP EQUIPMENT WILL BE ON 4-INCH FS510 KITCHEN EQUIPMENT ELEVATIONS SEE MECHANICAL SANITARY LEGS OR SEALED TO THE COUNTER UNLESS READILY MOVABLE. ALL LIQUID WASTE SHALL BE DRAINED BY MEMIS OF INDIRECT WASTE PIPES INTO ® All— WALLDRAWINGS FOR EXACT PARAPET WALL BY GEN. 24 A FLOOR SINK FLOOR SINKS ARE TO BE INSTALLED FLUSH WITH THE FINISHED ❑m❑❑ CONFIGURATION AND CONTRACTOR REFER TO 4 IF SOFT DRINK,ICE OR OTHER DISPENSERS ARE EFlLLS E SELF-SERVICE,OR IF R FLOOR SURFACE AND HAVE SUITABLE EASILY RE ATES.MOVABLE SAFETY OVER GR SPECIFICATIONS. ARCHITECTURAL PLANS ARE PROVIDED THEY MUST BE PUSH BUTTON TYPES OR LEVER TYPES WHERE THE FLOOR SINK IS TO BE 50%EXPOSED WHEN NO ACCESS IS PROVIDED FOR CLEANING i� n I� VENTED CURB FOR REQUIREMENTS LEVER CONTACT5 THE CONTAINER AT LEAST ONE INCH BELOW THE RIM. 25 OR BE IN LINE WITH THE FRONT FACE OF ELEVATED FREESTANDING EQUIPMENT. Foodscr6ce Design,E#mcnt and Sappis 5 ANY OPENABLE WINDOR5 VENT OPENINGS OR OTHER SIMILAR OPENINGS MUST BE 26 APPROVED BACKFLOW PREVENTION DEVICES SHALL BE PROPERLY INSTALLED 11ff PROVIDED WITH TIGHT FITTING 5CREEN6 OF MINIMUM 16-MEN TO THE INCH, 2 8 0 1 M c G a W A v e n u e WINDOWS TO BE FIXED AT FOOD PREP,UTENSL-WA5HING,OPEN FOOD AND UTENSIL UPSTREAM OF ANY POTENTIAL HAZARD BETWEEN THE POTABLE WATER SUPPLY I r v i n e, C A 9 2 6 1 4 STORAGE AREAS. AND A SOURCE OF CONTAMINATION,HOSES SHALL NOT BE ATTACHED PR VI A FAUCET STANDARD w RD MENU OR HOSE BIBB UNLESS AN APPROVED BACKFLOW PREVENTER IS PROVIDED. fVR/ML/ IYNGIRA T S 1 9 4 9.4 7 4. 1 0 0 0 6 ALL EXTERIOR DOORS OPEN OUTWARD AND ARE SELF-CLOSING AND TIGHT FITTING. 21 WATER SUPPLY TO CARBONATORS ALL BE PROTECTED BY AN APPROVED I-a K 9 4 9.4 7 4. 1 1 2 2 HANGER RODS 21 �y y�W.t r im a r k u s a,c om BY GC 3"MINIMUM-Do MAXIMUM 1 BI-FOLD,FRENCH,ACCORDION STYLE AND ROLL-UP DOORS CANNOT OPEN INTO REDUCED PRESSURE PRINCIPLE BAGKFLOW PREVENTER THE RELIEF VALVE AIR SPACE-TYP.RATED THE FOOD PRE,UTENSIL WASHING OR IN PACKAGED FOOD SERVICE AREAS. SHALL DRAIN INDIRECTLY TO SEWER WITH A LEGAL AIR GAP, THIS PUN AND THE DESIGNS HEREIN ARE THE SOLD PROPERTY OF FRIMARK RAYGAL AND MAY NOT BE REPRODUCED,CLANGED DUCT OR USED BY ANYONE,IN PART OR WHOLE,WITHOUT THE 8 TOILET ROOM AND DRESSING ROOM DOORS MUST BE SELF-CLOSING,TIGHT FITTING. FOR CLEANING FLOOR MATS,THE JANITORIAL SINK TO BE A MINIMUM 24"BY 3go cwwe�[� WFET" reMlsslox of A TRIMwK RnrGAL COMPACT omc(R. 28 FLOOR-MOUNTED TYPE.MOPS SHALL BE PLACED IN P051710N THAT ALLOUIS THEM .71tFi.B RIe DEBATING To THIS PUN MUST R APPDONED IN T wRlTxc BY 1RIMALtN OF A T BEFORE SUCH WORK Is DONE.li 9 DELIVERY DOORS TO HAVE AIR CURTAIN FANS THAT SPAN THE WIDTH OVER THE TO AIR-DRY WITHOUT SOILING WALLS,EQUIPMENT,OR SUPPLIES. w.,«.•^M+oop ms{+r To dl IS THE RESPUNSIBIUn OF ANYONE USING THIS PION TO READ SHAFT BY GEC. �. D BECOME FAMILAR WITH ALL INFORMATION SHOWN HEREON DOOR THE FAN MUST BE ACTIVE VIA A MICR05UIITGH PROVIDING MINIMUM French Fries sLes INCLUDING ANY usr OF NOTES.MEASUREMENTS ON THIS PUN CONTRACTOR TO COMPLY VELOCITY OF 1600 FROM MEASURED 3 FEET ABOVE THE GROUND. 29 THE JANITORIAL SINK FAUCET WILL HAVE A THREADED OUTER LIP FOR HOSE ARE FROM—BLE INFORMATION,THIMUTK RAYGAL Wn1 NOT W/LOCAL CODE. Col..Rise ASSUME ANY RESPoNSIBILItt FOR THE ACCURACY OF SUCH ATTACHMENT AND AN APPROVED BACKFLOW PREVENTION DEVICE.NO CHEMICAL iwmrp.ue.Bias s:.es BURGER GRILL INFORMARON RABBIarofis,COUTRADFORS,ETC USING THIS 10 A MINIMUM OF 10 FOOT-CANDLES OF LIGHT MEASURED 30"OFF FLOOR 15 DISPENSING 5Y6TEM5 OR SHUTOFF VALVES TO BE ATTACHED TO MOP SINK DIAL.salad/side Caesar sazs TPLANLoeESTO CON RM ALL IMF MATION vN THIS PLAN WIN PROVIDED IN WALK-IN REFRIGERATED STORAGE MID DRY STORAGE ROOMS AND FAUCET OUTLET(UNLE55 A"SIDEKICK"PLUMING DEVICE 15 INSTALLED). GENERAL CONTRADFOR OR THE GENERAL CONTRACTOR'S AT LEAST 20-FOOT CANDLES 15 PROVIDED WHERE FOOD 15 PROVIDED FOR �.wwB SUBCONTRACTORS TO PERFORM wIeINc,BUDIFFICAL,CURes, fMISHED CEILING B7 5/5 TRIM C wnus,aulLUINC oPEMxcs,Erc.ARE roR THE SOLD CONSUMER SELF-SERVICE,WHERE FRESH PRODUCE OR PREPACKAGED FOODS 30 NO CONDENSATE OR WASTE WATER INCLUDING HVAC WILL DRAIN INTO JANITORIAL SINK. PURPOSE OF EQUIPMENT REOUIR NENTS;REFERENCE Is MACE GENERAL CONTRACTOR BY KEC. CONTINUOUS WELDED n.dwa.;rM.w;w,,,vm. TO THE°INNER OR ARCHITEaURAL PUNS FOR ENGINEERING OR ARE SOLD OR OFFERED FOR CONSUMPTION:INSIDE EQUIPMENT SJCH AS REACH-IN LISTING of ITEMS NOT SUPPLIED BY TRIMARK R—L.TRIMARK CONNECTION DUCTj BY i0 AND UNDER-COUNTER REFRIGERATORS:IN AREAS USED FOR HANDWASHING, 31 GREASE TRAP TO BE LOCATED OUTSIDE THE FOOD SERVICE ACTIVITY AREA, shake,w„m..or,e,.I,I,,r.,"n.,..,.a, RAYGAL WILL NOT ASSUME ANY RESPoxsuwTY FOR HOOD PLENUM BY KEC. FLUSH WITH THE FINISHED FLOOR WHEN INDOORS.LOCAL WASTEWATER DISTRICT Sz95 ENGINEERING THEREOF ALL BUILDING WORK THEREOF SHALL DE MAKE UP AIR DUCT UIORdC B7 FIRE DAMPER IN WAREWASHING,EQUIPMENT AND UTENSIL STORAGE,AND IN TOILET ROOMS. Maus mwsroa« M..,R,.m.,..�,II, BY THE GENERAL CONiRANA INCLUDING ALL ROUGHING-IN OR BUILDING DEARTMENT TO BE CONTACTED FOR GREASE REMOVAL .. szes D FINAL CONNECTIONS AND ALL RUNS TO EQUIPMENT AND MECHANICAL CONTRACTOR MLA COLLAR7 (.o INal.a"�waa,a,m s, INCLUDING ALL FILINGS DR ANY OTHER PARTS MATERIALS OR II A MINIMUM OF 50 FOOT-CANDLES OF LIGHT MEASURED 30"OFF FLOOR IS REQUIREMENTS, LABUR FOR SUCH WORK. SUCH WORK IS IN TRIMARN SEE MECHANICAL DRAWINGS sundaes.,"u«e..,..m.N,,,n�„•Ma«,a cn1 I INTRACT,IT WIu 1111IRCAUY BL NDICATLD ON THIS FOR EXALT CONFIGURATION PROVIDED WHEN LJORKINGSLICERS,WITH FOOD OR WORKING WITH UTENSILS SA ETY Is EQUIPMENT Wn�Ap.+.".m,.e w„ .zs PUN;IF IT Is NOT SPECIHCALLY INDICATED ON THIS PUN,IT AND SPECIFICATIONS. SUCH AS KNIVES,SLICERS,GRINDERS,OR SAWS WHERE EMPLOYEE SAFETY IS A 32 FLOOR DRAINS SHALL BE INSTALLED IN FLOORS THAT ARE WATER-FLUSHED FOR Is NOT A PORT DF TRIMARK RAGAL CONTRACT Fro SHOL BE PRONGED BY OTHERS TRIMARN RAYGAL WILL ASSUME NO NON-CAMBIIST BLE WALL FACTOR AND IN ALL AREAS DURING PERIODS OF CLEANING. CLEANING AND IN AREAS WHERE PRESSURE SPRAY METHODS FOR CLEANING w�� RESPONSIBILITY FOR WORK DONE BY THE GENERAL oo�T—IR CONNECTION TO HOOD BY b' EQUIPMENT ARE USED,IN RE5TROOMS,JANITORIAL ROOMS,SCULLERIES,AND AT yFPoek.a COB A SUBCONTRACTOR OF THE GENERAL CONTRACTOR OR ANY MECHANICAL CONTRACTOR 9 M BY GENERAL C04iRAL10R CHANCES MADE NECESSARY BY LOCAL CODES(INCLUDING: (STRUCTURAL STEEL STUDS 12 SHATTERe IELD5 FOR ALL LIGHT A50VE FOOD PREPARATION,WORK,AND BARS WITH WAREWASHING.FLOOR SURFACES IN AREAS PURSUANT TO THIS SHALL TWA BUILDING,HEALTH uwART.ORNINANCES,nRE DEPART.,ETC.) `r RECOMMENDED) STORAGE AREAS WILL BE PROVIDED. BE SLOPED 1:50 TO THE FLOOR DRAINS. ��- ®®®® oR CHANCED SY THE OWxEN,ARCHITECT DR ANY OTHER PERSON OUTSIDE OF TRIMARK RAYGAL WITH ALTHORRY TO THE + d vkd I,Fd T DESIGN. THIS PION BECOMES VDID UPON SUCH CHANGES AND F 13 ALL WAREWA5HING SINKS TO HAVE 3 COMPARTMENTS THAT ARE A MINIMUM SIZE 33 ADEQUATE VENTILATION 15 TO BE PROVIDED TO ALL TOILET ROOMS,JANITOR •W. % IL"'P WORK CANNOT BE COMPLETED UNTIL THE APPROPRUTE a HRe.....S,.T. Large s,... CORRECTIONS ARE MADE BY TRIMANN RAYGAL USING THIS PUN £ OF Ar LEA5T 18"X18"XI2"DEEP(OR 16"X20"XI2"DEEP)WITH A MINIMUM IB" CLOSETS WITH MOP SINKS,AND INDOOR TRASH ROOMS AND IN DRESSING AND At The Habit aw dwlunan 2 Is AOMIEXAMINED AND THAT ALL INFORMATION ON PLANS PUN BEEN '0 9NARK ) DRAINBOARD AT EACH END.IF AGAINST A WALL,IT MUST HAVE AN 6"INTEGRAL CHANGE ROOM($) �� d.rwr� h WII2 AR—ED AND COMPARED rmH OTHER PUNS RE (EXPORTED 1R U x �1y{ ARCHITECTURAL PUNS)AND ANY INCONSIBTENCIE$ERRORS, •e-r BACKSPLASH.HOWEVER,IT MUST BE CAPABLE OF ACCOMMODATING THE V.s x n,+.admon(...wr fo.ty AMBIGUITIES MI W TEN 1 O NAME BEEN RRE CUMC To LRIBIDS LARGEST UTENSIL TO BE WASHED.A WAREWASHING MACHINE DOES NOT 34 THE FLOOR FINISH WILL HAVE A SMOOTH SURFACE UNDER ALL EQUIPMENT AND The yraas.Nn,aH..4 shr+ad..r,..�MOLT, RAYGAL FOR l G AN coR HEREUNDER.BEFORE cADDRO AL BIDS OR COMMENCING ANY WORK HERE NO ADDITIONAL WALKWAYS WILL HAVE A LIGHT TEXTURE ONLY. euu6ER6Rlll a Oa p1e O0^'"'U"1C^T+o sdl + AllOWD BE WILL BE MADE MR SUCH WORK UNLESS IT IS COOKING EQUIP. SUBSTITUTE FOR THE SINK REQUIREMENT. F wvSus In Sa.Ha 8avbara. EAGiEcil°ICABLEPOS PARTS NOT SO OF BIDS.PLUMBING UDR u A ELECTRICBY KEC THE PAINT USED ON WALLS AND CEILINGS OF ALL KITCHEN,FOOD PREPARATION,WOW, "• .,,..CALM s"m ELECTRIC°ITEM SHALL BE P—DED BY THE PLUMBER OR 14 SINKS TO HAVE 5POUT(8)CAPABLE OF REACHING EACH COMPARTMENT. 35 1M,Ile a...an"and eecl.Kss Iwx STANDARD I UNLESS SPECIFICALLY INDICATED ON TNs PUN. AND STORAGE AREAS WILL BE A GLO56 OR SEMI-GLOSS ENAMEL.FINISH MATERIAL . .a... $rA,ay„ti still aporaro"naa.+wr 15 FOOD PREP-SINK COMPARTMENT(6)15 TO BE AT LEAST IB"XI8"XI2"DEEP(OR SHALL BE A LIGHT COLOR IN FOOD PREPARATION AREAS FOR EASY CLEANING. r am.x<. am.. w..w mmmHWv.H Wd.,r raA. ❑ I6"r20"X12"DEEP)WITH A MINIMUM 16"DRAINBOARD SEPARATE FOOD PREP-SINKS y.menwrn" �YaWe..<a.Mhaem"x .rreelAs iFti lama. 15 TO BE PROVIDED FOR MEATS AND PRODUCE, 36 PRIOR TO INSTALLATION,SAMPLES OF FINISHES 70 BE SUBMITTED TO Substitute pg•Dt•g017 ® N DEP ENVIRONMENTAL HEALTH FOR APPROVAL AS NEEDED. •The For Qore's No Su Subst 16 THE 3 OR 4 COMPARTMENT BAR SINK TO BE AT LEAST 12"XI2"XI0"DEEP(OR ``" ❑ I. FOOD HEATING OR WARMING DEVICES SUCH AS CHEESE 3- MECHANICAL EXHAUST VENTILATION SHALL BE REQUIRED 1, NON-CANOPY TYPE HOODS:UNITS ARE APPROVED 10"XI4"XIO"DEEP)WITH A MINIMUM 18"DRAINBOARD AT EACH END. 31 COLD STORAGE RODS SHALL BE PROVIDED WITH A SECTION INSTALLED TO HOLD SHALLOW COOL DOWN PANS-NOT TO EXCEED 4"IN HEIGHT,SHELVING kt..1969 MELTER5,ETC.,THAT ARE INSTALLED ABOVE OTHER AT OR ABOVE ALL COOKING EQUIPMENT SUCH AS RANGES, PROVIDED-THEY ARE CONSTRUCTED 10 BE EASILY EQUIPMENT BENEATH AN EXHAUST HOOD,MAY CREATE AN GRIDDLES,OVENS,DEEP FAT FRYERS,BARBECUES AND CLEANABLE AND THEY COMPLY WITH THE MINIMUM EXHAUST o- r ❑ 11 A SEPARATE WET WASTE DUMP FIXTURE SHALL BE PROVIDED FOR DISPOSAL OF SPACE BETWEEN SHELVING TO BE AT LEAST S" ElHIGH. AIR FLOW DRINK OR WASTE ICE OR COFFEE WASTE.OBSTRUCTION TO PROPER VENTILATION OF THE ROT165ERIES 70 EFFECTIVELY REMOVE COOKING ODORQ AIR VELOCITY REQUIREMENT5.SHIELDING AT THE ENDS OF 38 BACKUP DRY STORAGE SHELVING 514ALL BE A MINIMUM OF%LINEAR FEET EQUIPMENT FOR WHICH THE HOOD VENTILATION SYSTEM IS SMOKE,STEAM,GREASE AND VAPORS. THE HOOD MAY BE NECESSARY TO PREVENT INTERFERENCE 18 EACH HANDWA5HING SINK MUST HAVE PERMANENTLY MOUNTED SINGLE-SERVICE (MEASURED WITH TIERS)OR 25%OF KITCHEN,FOOD PREPARATION,AND WOW ❑ DESIGNED.THEREFORE THE DESIGN,CON51RUC110N AND FROM GR055 DRAFTS. SOAP AND PAPER TOWEL DISPENSERS, AREA5,WHICHEVER IS GREATER.SHELVING SHALL BE AT LEAST IS INCHES DEEP ElINSTALLATION OF SUCH WARMING DEVICES UNDER A HOOD 4. ALL HOODS,DUCTS,AND EXHAUST OUTLETS 5HALL BE AND START A MINIMUM SIX INCHES OFF THE FLOOR SURFACE. ARE SUBJECT TO EVALUATION AND APPROVAL BY T1416 INSTALLED IN ACCORDANCE WITH THE CURRENT EDITION OF T3, MAKE-UP AIR:ENGINEER MADE MAKE-UP AIR SYSTEM THAT 19 THE WATER HEATER WILL CONSTATNLY SUPPLY 120 DEGREE FARENHEIT COMMERCIAL ❑ AGENCY PRIOR TO INSTALLATION. THE UNIFORM MECHANICAL CODE AS ADOPTED BY THE PROVIDES AT LEAST 80%MUA WHICH S MECHANICALLY 39 SHELVING OVER WET AREAS(SINKS,MOP SINKS ETC)AND FOOD PREPARATION LOCAL BUILDING DEPARTMENT. EXHAUSTED.WINDOWS AND DOORS WILL NOT BE USED FOR TYPE HOT WATER TO ALL SINKS.IN SIZING THE WATER HEATER,THE PEAK HOURLY CANOPY-TYPE HOODS:THE LOWER LIP OF CANOPY-TYPE THE PURPOSE OF PROVIDING MAKE-UP AIR R R DEMAND FOR ALL STANK ETC.,ARE ADDED TOGETHER i0 DETER MINE THE MINIMUM SURFACES WILL BE METAL. WwF1�eeGY SgIpW�CFIES 2 HOODS 5HALL NOT BE MORE THAN SEVEN FEET A50VE THE 5. ALL JOINTS AND SEAMS 5HALL BE TIGHT OR SOLDERED FOR REQUIRED RECOVERY ATE. 40 ALL SEMIS,GAPS,OPENINGS TO BE PROPERLY SEALED. FINISHED FLOOR AND SHALL NOT BE MORE THAN FOUR FEET EASE OF CLEANING.RIVETED SEAMS ARE NOT ACCEPTABLE. 9. FIRE EXTINGUISHING SYSTEMS:FIRE EXTINGUISHING SYSTEMS MAY REQUIRE LOCAL FIRE DEPARTMENT CODES.INSTALLATION 20 ALL LAVATORIES T HAND SINKS WILL HAVE A COMBINATION FAUCET OR (hiekevR,"a.In�a,n.I=„eT„e�Ir"as,M,..",P 0 ABOVE THE COOKING SURFACE.THE HOOD CAPTURE AREA 6. EXHAUST HOOD 15 ELECTRONICALLY INTERLOCKED WITH PREMIXING FAUCET CAPABLE OF METERED FAUCET WATER TEMPERED TO 100 DEGREES SHALL AN TANG OR EXTEND A HORIZONTAL DISTANCE NOT ALLOWS EASY ACCESS TO CLEAN BOTH HOOD AND DUCT fAHr�ENHEIT SELF-CLOSING OR METERED FAUCET TO PROVIDE AT LEAST 15 LESS THAN SIX INCHES BEYOND THE OUTER EDGES OF THE MAKE UP AIR(MUA)DUCTS.SEE EXHAUST HOOD DETAILS SYSTEM.IT 15 NEVER N IN INSTALLED ABOVE ANY TYPE OF COOKING SURFACES,ON ALL OPEN SIDE$.CANOPY HOODS FOR WIRING DIAGRAM. FOOD OR UTENSIL HANDLING AREAS SECONDS OF WATER WITHOUT REACTIVATION. „"".ro."e>a"•"ee aeo":..,,..,e se.zs Q SHALL HAVE GREASE TROUGHS AND DRIP PANS T.. THAT ARE Fresh Albacore ..�. ".nre� EASILY GLEANABLE. r.re 0 ��', Veqqie Burger "s a� +�q WN g19xd w{vMn rAip ksnrM1 s 'wo"r:..en�olw.ia?s fM1O Q 1"nafo,canne!><d pah aa"p"'R P'r#ks, Chi I(lab U, o imthd M N.S.F. SNEEZE GUARD DETAIL S/S BAR WITH SNEEZE GUARD SPECIFICATIONS (hIIONUIU Res w rd mw^."5s` Q DoubI.OWWburger ea.es R�����gW� Teriyaki(harburger Sa.zs w BB smas THIS FOOD FACILITY IS 100% eBQ .s rger sce. W bM 2,b SINGLE SERVICE M ... od" nsh.on wis O(hMSa.as Garda�faaa F1em.n b w ILL] 6 1/4'A 3 1/2' MATERIAL SPECIFICATIONS 16 GA s 6Hlled(hick..salad _,.n.y;,.e,m /Z)M CUr-OUT SIZE TO OPEN ggqqqq(( SHELF-16 G4 S/S 9' 10' SHED �g� ,>�.:,Col .m, I�`�.�,n�.;,,si 9s M�..4 M ACCEPT 1/91H SIZE + AND BOTTOM TOP-16 GO,S/S BBR ORIGINAL n g_er, "a. ,� LJ PAN FOR CITRUS SIDE UNITS-16 GA S/S 6rillad(hick.Gnar Salad rn"pP,e m*,�re (� / DETAIL•A' #11(�karb�m em �.:ee.��n e.�=a eT,v .tea,,awn a„�, (— OPEN BACK �• OpETN BACK POST-11'SCL S/S TUBING m. 9e s ss.z. v,,.,,..m.,PP.e.mm,y"ill.e.r re"n�,�Sass w Q 10• 30' 1Or CLASS RACK-18 Gl S/S B2 D.uble(lac BBQ(hi<kev Salad Ram n<..r —8 GLOSS-TE•THIN.CLEAR TELPERm I.Iwnr,�A. ,�"k a.z. m" wm,w e��� n u:is�.mm�." LU — '� RUBBER FEET-C.HG 0-2W6 REFER TO ARCHITECTURAL DRAWING # y „� Gn(aBgkwsra(o ecrM`SL "" OC uS NSF COMPLIANT :e �' 15B 1• E�OSE BKMVOF my RBI�iRF11 G.7 ��s `�`"er,r � J SHEET A230 FOR FINISH SCHEDULE HEALTH CODE POINTS '= WEDNE BD DN OPEN eIGik,.+o ITEM SAL �� EDGE (h m6rlled(heMeNaspeb, u«� „es9O d W I-I..I Q cr +60"AFF S/S BAR ITH o �— + __ ".., °"'�`wn`.",.:a";:d L.L SNEEZE WARD ttP. st M .«,,..:`.`v ",•'°'U.,., cOc Z +54"AFF S/S PANELS H TYP. m G 1#'SQ.S/S BOTH SIDES • TUBI hP. J 3e COVED SPLASH Br "E EDGE I• 2• I#' J ~ 3K 7 Iles CUT-OUT 7�. IL FOR PEPPERS Tar• 16 Gk RECESSED 3t• CUT-0UT CUT-0Ur µD BABIK BORROW N O O rj S/ POTENTIAL 3/8• 3/8'S/S.ROO CONTAMINATION Pausllm aAss TO HOLD CUPS - SECTION A—A AREA AND DBL PAN(S/S. DESIGNER: LINGLEDE6IGN INC. CUT-PUT FOR N1%(INNS$�� AN LEFT AND io ITEM 43-CONDIMENT NAPKINS SLIDE IN FROM P I.D.D RIGHT SIDES DRAWN: TRIMARK RAYGAL ro N COUNTER WITH DRY �K CABINET BY MILLWORK �• 1#• S/S.TUBING CHECKED: TRIMARK RAYGAL CONTRACTOR /Y GLOSS J SCALE: N.T.S. JOB NUMBER: 58080 `a SHEET TITLE 7 *x•� RILLY�µD COVER SHEET n? POLISH SNEEZE GUARD RUBBER FEET ON POSTS 0/32 a 1/2' SIDE-COREINEICT 7�' 32�• 7�' t10WIM 3 PIECE TO SPLASH S/S.GLASS TRACK S/S.PAN(HD WS UNITS ALSO ASSEMBLY STANDARD. A SEE DETAIL'B' S/S BAR WITH SNEEZE GUARD DETAIL "A" SHEET NUMBER FS010 OF SHEETS EQUIPMENT LIST EQUIPMENT PLAN GENERAL NOTES THE GENERAL CONTRACTOR WILL BE RESPONSIBLE FOR ASSURING THAT KEL.RECEIVES COPIES OF ALL ADDENDUM AND CHANGES TO BUILDING _ PLANS WHICH WERE MADE BEFORE AND DURING CONSTRUCTION.IF THE INFORMATION WAS NOT DELIVERED TO KE.C.,THE GENERAL CONTRACTOR ' cuRruN , cuRrRON WILL BE RESPONSIBLE FOR ALL COSTS INCURRED BY FAILURE TO GIVE K-E.C.THIS INFORMATION, 2. KE.C.PLANS ARE PROVIDED FOR THE SOLE PURPOSE OF INDICATING - ROWI4-IN LOCATIONS AND EQUIPMENT REQUIREMENTS.K.EL.PLANS DO _NOT RELIEVE THE GENERAL CONTRACTOR AND 5U8-CONTRACTOR THE RESPONSIBILITY OF COMPLYING WITH ALL APPLICABLE CODES. - I-�1 T ,{ 3. PROVISION SHOULD BE MADE TO"DOUBLE-STUD"AND/OR SOUND - 1 y1 \/ /]y� PROOF COMMON WALL BY THE GENERAL CONTRACTOR WHERE NOISY _ 1 1.1.L�1L1.1 OR VIBRATION PRODUCING EQUIPMENT 15 LOCATED ADJACENT TO ❑m❑❑ DINING AREAS. 4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL GENERAL i� C I� CLEAN UP,DISPOSAL OF TRASH,CARTON$,CRATE5,DEBRIS,ETC., e.a EMIcx D1saENSER , s FoodsciNce Deso,Bgmpmentand Supplies AFTER FINAL INSTALLATION OF ALL FIXTURES. 11/1 5. 114E GENERAL CONTRACTOR 15 i0 CUT OR PROVIDE HOLES THROUGH 2 8 0 1 M c D a W A ye n u e 52.1 55 CEILING,ROOFS AND WALLS FOR DUCTS,ETC.ACCORDING TO THE DUCT I f Itl D e C A 9 2 6 1 4 SIZES THAT ARE SPECIFIED ON 114E KEC.PLAN.GENERAL CONTRACTOR T e l 9 d 9.4 7 4. 1 0 0 0 523 521 52J 54 S TO PROVIDE ALL DUCT FIRE SEPARATION ENCLOSURES,WRAPPINGS, a TER HE— , s no.sNlr" ET",za F x 9 4 9.4 7 4. 1 1 2 2 ETC,MAY BE REQUIRED 0 BY LOCAL BUILDING AND FIRE CODES. F a trimarkusa.com 6. SPRINKLER HEADS IN FREEZER BOXES WILL BE ADEQUATELY - - PROTECTED AGAINST FREEZING UP BY GENERAL CONTRACTOR ,z C NIC R , s Or TRI AREµRPYGTFLE AND MASY HEREIN ARE REPRODUCED CHANGED 11 T. THE GENERAL CONTRACTOR S TO VERIFY ALL ROUGH-N LOCATIONS WR1riENDPERMISS1oNE'OFA TRMWK WHOLE,COMPANY OFFICER. I % 5211 ____ UGS IN BEFORE SLAB 15 POURED,WALLS AND CEILINGS ARE CLOSED,OR ANY11 E DMARK xs To B%ISEFORE RE S usr RE ARPDONED WRITE EY IRIMWK RAYCPL REfORE SUCH WORK S DONE.IT E- 5T g0 OTHER WORK LIMITING ACCESS TO ROUGH-INS ARE FlN15HED,IT 15 114E IS THE RESPoxsmi of AxroxE uslxc Tws PUN ro RFnn I D BECOME FAMIWR wNH ALL INFORIEMEN sHOwry IS P -- ,s.s sRaRe NUMeeR ' rcec cusroN RA.eRIcnrloN cusroM GENERAL COJTRACTROR'S RESPONSIBILITY i0 CONFIRM ACCURATE „ s�RE NUMBER osv a INCLUDING EFROM ANY Llsr of NOTE N NIMAMENrs ON THIS PION 58 � i PLACEMENTS OF ROUGH-INS AND COORDINATION WITH ANY OTHER +es ARE FROM AvauBlE wroreMAnaN.TRIwRK wncu mu NOT ,3s ASSUME ANY REGPoNSIBILItt FOR THE ACCURACY OF SUCH 45 2F REQUIREMENTS OF SUBTRADES. ,sr wroRlAnnoN.FABRIGArofts,coNTRAc*ores,Erc uslxc TH¢ P----�PY ___ PIAN ARE i0 CONFlRM ALL INFORMATION ON THIS PVN WRH -- THE JOB SIrE.ALL INFORMAnON ON rEIIE,EL FOR THE 45J PRE-RINSEe RoucerNrc , rcEc • I I I I 'I r -- 36" 42" 42' B. ALL EQUIPMENT SHALL BE PLACED ON A MINIMUM OF SIX INCH HIGH, ,<., cENERu coNTftnc*ore aft TxE cENERa coNTRAcroR's EASILY CLEANABLE LEGS OR ON A FOUR INCH HIGH CONTINUOUS COVED suecoxrRACTores TO PERroRM(PWMRINc,ElccrRlcA1,cuaes, ,az vE,�ER wrsre 3 ,a.> wlRe sHeLVINe Lor WALLS,BUILDwc OPENINGS,ETC.ME FORE THE SOLE _ N BASE MASNOJRY CURB OR ON APPROVED COMMERCIAL CASTERS OR rcec Nexe1 N _ I I -- v 4T� �4T I 62 I I 4T 4T 4T ,s "Enr som TnNrc , rcEc NvsINEx a°ru.ci vaclTv PURPOSE OF EOOR AR i REOUIR MENTS;REFERENCE IS MADE _= CANTILEVERED FROM 114E WALL IN AN APPROVED MANNER. M,w Rowoo TO THE OWNER OR T 111 CTUR41 PLANS FOR I.EERIMA oR 24' 24" ___ ,s ICE rvwcNINE ; rcEc - FRALIS HC OF NOT ADS SUPPLIED BY TRIMAONGIB K RAYGAL.iRIMMK 4T 32 i _��� 2.1 1'i 22 18 ie aRCHECKIwioGOERON RooEI ,D rcEc BY THNGENERAL COFo ACIDAR INCLUDING ALLHRO G 33 i I 1 132 133 13 BA I .x. I ERwc CONNECTIONS SHALL BE b GENERAL CONTRACTOR INCWDING Ill ROUGHING-IN 4T 5 I b 2 i N 23 D IiTING1 OAND ANY OTHHERsp O�MATEERN oR 24J J qT IARM FOR SUCH WORK.F ANY SUCH WORK IS IN TIRIMARK I,Ec r�aLecRat-r ssas _ _ _ __ ,s, z<oHEorc HovoER TAaLECR�T ssz< NTRACT,IT 4T 4T d-- 202 - 36" 42 42 WI HI�°:PITON TO WITH I/0411:IZ"PIDCN TO ITN/4"- PIiDCHO zzNz eR hoLOER��os"ELF z Ec cis oMFo�eRlicn,IiorNi cuSTDM 5 sow F PLA,N;IF IT IS NET woRNMARE BY THE ASSUME PNO ILL SPECIECY BE INDICATED ON Txs IEI ECIFlCALY INDICATED ON THIS NOTED PART IF T.TRMARK RAYGAL WILL T.1 SHALL BE SILTY FOR GENERAL CONTRACTOR I 32 I 4T 4T 4T OR A SUBCONTRACTOR OF THE GENERAL CONTRACTOR OR ANY 3 GREASE CATCH BOX ASE CATCH WX CATC14 BOX CHANGES MADE NECEssUtY BY LOCAL CODES(INCLUDING: 1 I RUIWING,HFALTH DEPART.ORDINANCE$FIRE DEPORT.,ETC.) OR CHANGES BY TI,OWNER,ARCHITECT OR ANY OTHER 'L _ z29T c�azeROKLEIsscorv.BIT ' WORRE�E BEE ALLLETE wOK Poems USING THIS REND 522 rcec PI�KTi HTroR sss"ssssrc srRo DES°FLESHTHIS PLAN BECOME VOIN E TRIM O_ 3 U 31 20J II I 32 — II zs REFRICERnTED EDDIPI�NT STAwD , Ec gpYCPLNON WRRIENVCORRECTIONS BEFORE COMPLETING BIDS PLAN CANNOT EiEO ARCHITED NY INCON I ERRORS, rcec DDRKaN cese-Her, IILOWINCEE WILLOBM SHAVEBER REPORTED BEEN cusrartn EnsRlcaTIDN cusronn OR KEa aoNTINENTx DLB9a F S HAVE B RIBI�OB 39,1 WORK HEREUNDER NO JNLS11N1 14 141 142 W3 xr c"NT—rote OI EHe" , w 1— SUCH WORK UNLESS R IB 3<_3 _ _ - AGREEDE11RU BEFORE ACCEPTANCE OF 111 PLUMBING OR ELECTRICAL PARTS ALL E PRMED WITH THE EPLUM ER PS A carvTINENTx 342 52 zs REE ALILT,TEO EOUIPI..�NT STIwo , rcEc o13so EEECTRCNNI UNLIEESS SPECfIGONDEDK'DIGIEo ON THIS P° s � 48" 54' 241 srs oulsrye�oc Lrs 4P1y'T _2______ _ _111 21 38 38J - 522 43 E. qT 30'1 30J 30J ❑ all, 23J ''8248 4T 4To., �sr09.01.2017F 'II N �4T 4T 09 ❑ q 3, ESUPPRESSIDN ssTEM I KEI ,wsuv N-,°z wET D"EMID„D _—_ 36. 362 6 10 u 4 ROOF MOUNTED EXHAUST FANS 2 - - 36 21J 521 I 19J 65 0 ❑ bl 502 ® ❑ 4T OY TO 1.NT.N EN 4 61 62 6,3 it-1 1 IL- ON 6.4 65 bb 11 1 1I 1 L 4T 43 44 45.1 45 46.1 46 L L-J-3 _ NIN1 0 49 49 303 EN Q ZL 0 <s A SNEWEN WITI,DISPENSER , S e NN TSso IT.1-ss w ROOF MOUNTED MAKE—UP AIR SYSTEM e, NINE I IEI —ITDwDD N,°ss.D o M °.s CUNIDEN.IN.u T I EB. M,wIT 1 IDuo-,<as - 00 yr w o ■� -—-—-—-—-—- J W W Q d—r-- 11"m oRDERrERMIN� ; � LL o z I....—NI-R 4 ow Tl 462 2A 3.4 - 11..RRINTe z s _ LL O MR ea Lo O N (h N Y' _^ /���C,'�C s3 s.I,DMETENMIN- , e ROOF MOUNTED CONDENSERS - DESIGNER: LINGLEDESIGN INC. HRu couNreR wicasH DRAWN: TRIMARK RAYGAL ss s "E THRU eEVEN CALT R , 6O srwowRSHELE s, a Puz"E-r , rcEc CHECKED: ?RIMARK RAYGAL oNnweR SCALE: 114"=1'-0" 1 "uFl 1/ - - JOB NUMBER: 58080 So ID"1RE TOELE , rcEc CorvTINENTx SCRs-R sn..Es I 11 Sw<s ws DOOR WITH wwoow z sc eunsoN Rssxsa I II I ss srs ovERSHELE rcEc cusrol.,EasRIcaTION cuSTDM I 11 I ' SHEEf TRLE --- sT "wsT H000 I—, N EQUIPMENT PLAN T GREASE NTEROEPTOR- E ARCHIT C DRAW FOR$pE CIC TION, LOCATI AND�REMENTS u.l 11 T— SHEET NUMBER FS2001 GREASE INTERCEPTOR - —Ol— , eD _NIEY OF SHEETS EQUIPMENT ROUGH-IN REQUIREMENTS AL CONTRACTOR NOTM ��AL FACTOR NOTM EQUIPMENT LIST PLUMBING REQUIREMENT ELECTRICAL REQUIREMENT o o —o _ — — — _ E.1 ALL ELECTRICAL REQUIREMENTS INDICATED IN THESE PLANS ARE P.I ALL PLUMBING REQUIREMENTS INDICATED IN 114E PLAN ARE FOR ,. z — z FOR KEQ.AND/OR OWNER SUPPLIED EQUIPMENT AS SHOWN ON K-I KE.C.AND/OR OWNER SUPPLIED EQUIPMENT A5 54OWN ON K-I o_ o w _ o_ m w SERIES EQUIPMENT PLAN AND DESCRIBED IN K-2 SERIES EQUIPMENT SERIES EQUIPMENT PLAN AND DESCRIBED ON THE K-2 SERIES SCHEDULE WHICH REFERS TO THE ARCHITECTURAL AND ENGINEER EQUIPMENT SCHEDULE WHICH REFERS TO THE ARCHITECTURAL AND ra c�rzTnlN , I<Ec c�FxTrzoN �w-Asa-,-ss ,zon ,ra HE FxEo n-IR�,ecTlvaTeo DRAWINGS,GENERAL CONTRACTOR AND OMER FOR ANY ADDITIONAL ENGINEER DRAWINGS,GENERAL CONTRACTOR,AND OWNER FOR ANY REQUIREMENTS NEEDED.ALL ELECTRICAL EET SHALL COMPLY WITH ADDITIONAL REQUIREMENTS NEEDED,ALL PLUMBING WORK SHALL ALL APPLICABLE CODES AND/OR GOVERNMENT AGENCIES HAVING COMPLY WITH ALL APPLICABLE CODES AND/OR GOVERNMENT JURISDICTION OVER PROJECT LOCATION. AGENCIES HAVING JURISDICTION OVER PROJECT LOCATION. N E2 THE SYMBOLS$HOWN WITHIN THESE PLANS INDICATES THE LOCATION 2211 1AND TYPE OF ROUGH-INS.E.C.IS 70 PROVIDE AND INSTALL CIRCUITS P.2 THE SYMBOLS SHOWN IN THIS PLAN INDICATES THE LOCATION, AND CONDUIT RUNS IN ACCORDANCE WITH THE ELECTRICAL ENGINEER _ c„z°ar, ER�rvo FAN DRAWINGS,CONFORMING WITH ALL APPLICABLE CODES AND/OR TYPES OF ROUGH-INS,AND STUBS.THE PLUMBING THE CONTRACTOR GOVERNMENT AGENCIES HAVING JURISDICTION OVER PROJECT S i0 PROVIDE,INSTALL SUPPLIES,RETURN,WASTE,VENT,FUEL LINE TriMark LOCATION. PIPING IN ACCORDANCE WITH THE PLUMBING ENGINEER DRAWINGS, CONFORMING WITH ALL APPLICABLE CODES AND/OR GOVERNMENT E3 THE ELECTRICAL CONTRACTOR 15 TO FURNISH AND INSTALL ELECTRICAL AGENCIES HAVING JURISDICTION OVER PROJECT LOCATION. [�❑m❑❑SERVICES TO ROWH-IN LOCATION AND FROM II TO EQUIPMENT 1 POINT OF CONNECTION,IE:LABOR,MATERIAL,WIRING,SERVICE FITTINGS, P3 THE PLUMBING CONTRACTOR IS TO FURNISH AND INSTALL ALL ❑ ] i� n ]Supplies CONDUITS,CIRCUIT BREAKERS,JUNCTION BOXES,OUTLETS,PLUGMOLDS, PLUMBING SERVICES TO ROUG14-IN LOCATION AND FROM ROUGH-IN FOOdSCCNCC llCSI4mfII Equipment IIICtIt and SU TICS a n EMlcri oISPENSErz , osv ,iz ENQINEEra F•L,w FOR MORE SWITCHES,FULL BOXES,CONTROLS,SHUNT-TRIPS,NEMA CONNECTORS AND i0 EQUIPMENT POINT OF CONNECTION,IE:HOT WATER COLD WATER D"I 9 P PF CONFIGURATIONS,LOCK-OUT DEVICES,DISCONNECTS,PANEL BOARDS, DIRECT WASTES,SANITARY DRAIN LINES,FLOOR SINKS,FLOOR 11ff ETC.INCLUDING FINAL EQUIPMENT CONNECTIONS,AS REQUIRED AND/OR DRAINS,STEAM SUPPLY,STEAM RETURN,NATURAL GAS FUEL PIPING, 2 8 0 1 M c G a 11 A v e In u e NECE55ARY FOR PROPER OPERATION OF FURNISHED EQUIPMENT FITTINGS,UNIONS,STRAINERS,GAUGES,CLEAN CUTS,TRAP$,VALVES, r v i n e, C A 9 2 6 1 4 INSTALLATION SHALL MEET ALL APPLICABLE CODES OR GOVERNMENT STOPS,PRESSURE REGULATORS ETC.INCLUDING FINAL EQUIPMENT T e 1 9 4 9.4 7 4. 1 0 0 0 AGENCIES HAVING JURISDICTION OF PROJECT LOCATION. CONNECTIONS AS REQUIRED AND/OR NECESSARY FOR PROPER F a% 9 4 9.4 7 4. 1 1 2 2 a nTErz HEnTEa , osv .ao.SMITH ETH,zo -,is Iw aia ,rt ,zo To Es Ev Oc J12. unEs OPERATION OF FURNISHED EQUIPMENT INSTALLATION SHALL MEET w EEra EI_.w EOFx EA THE ELECTRICAL ENGINEER AND CONTRACTOR ARE TO VERIFY ALL APPLICABLE CODES OR GOVERNMENT AGENCIES HAVING W W W.t r i m a r k u s a,c o m ITEM 1. - REQUIREMENTS AND LOCATIONS OF OWNER FURNISHED EQUIPMENT WITH JURISDICTION OF PROJECT LOCATION. - - OWNER SELECTED SUPPLIER PRIOR i0 ROUGHING-IN ANY UTILITIES. THIS PUN AND THE DESIGNS HEREIN ME THE SOLE PROPERTY OE TRIMMR RAYGAL AND MAY NOT BE REPRODUCED,CHANGED P.4 THE PLUMBING ENGINEER AND CONTRACTOR ARE i0 VERIFY ALL oR USED Br ANYONE,N PART OR WHOLE,WITHOUT THE 'z aorv..TOa ' Os� "z Iw ' as Ps R"'-`WEo"IREMErvTs w1TH os.. E5 THE ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL REQUIREMENTS OF OWNER FURNISHED EQUIPMENT WITH OWNERS WRITTE�reEreMlsslox of A TRIMANK RnrGA COMPANY OFFICER. SEPARATE CIRCUITS FOR EACH SELF CONTAINED REFRIGERATOR IN OEAANoxS To THIS PUN MUST BE MPB D IN - - SELECTED VENDOR PRIOR i0 ROUGHING-IN ANY UTILITIES. IIS THE ESMNSIBK RAYGA NE USING IS P Is DONE.IT 4. AND/OR FREEZER,UNLESS OTHERWISE SPECIFIED. A THE RESPoxAMIMrr of ANYONE USING.HIS PION TO READ AND BECOME LIST t WITH ALL MEASUREMENTS SHOWN HEREON P5 THE PLUMBING CONTRACTOR 15 TO FURNISH AND INSTALL ALL ME FROM ANYM Usr or NOTES.NUSURENExrs ON THIS PUN Eb THE ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL LOCKOUT REDUCING VALVES/STOPS NECE55ARY AT HOT AND COLD WATER ASS FROM y RESBLE NILjTY R HE ACLU ACY O mUC NOT DEVICE ON CIRCUIT BREAKERS CONTROLLING EXHAUST BLOWERS, ASSUME ANr RESPaxslBarn FGR THE ACCURACY of SUCH MAKE-UP AIR FANS,ICE MAKERS,REFRIGERATION SYSTEMS AND FIRE SUPPLY LINES FOR GENERAL WATER PRESSURE NOT TO EXCEED INEORMARON FABRICATORS,CONTRACTORS,ETC USING THIS 40 PSIG MAXIMUM AT KITCHEN EQUIPMENT. PUN ARE M CONERM ALL INFORMATION ON THIS PUN WIN PROTECTION SYSTEMS,UNLESS OTHERWISE SPECIFIED. THE Jos SITE,Ill INFORMATION ON THIS PUN FOR THE ,-tiz to M-coMPwzTMErvT slrvrc t rcEc CUSTOM F.asalcnnory CUSTOM ow " GENERAL CONTRACTOR OR THE GENERAL CONTRACTOR'S Pb THE PLUMBING CONTRACTOR IS TO FURNISH 20 PSIG MAX.WATER suxcoxrreAc ores TO PERFORM LUMBING,BLE TRICAL RJRss, )_EVER wasTE a I<Ec FISHER zaoso E] THE ELECTRICAL CONTRACTOR IS i0 FURNISH AND INSTALL DEDICATED '.ZT BUILDING oPENwcs,ETc ME roR TxE so¢ ,a3 wIRE SHEL.arv� LOT rcE� rvExEL CIRCUIT RECEPTACLES WITH ISOLATED GROUND AND EMPTY CONDUIT PRESSURE AT WAREWASHER AND DISHWASHER PURPOSE OF EOOR ARC REQUIRE MEMS'REFERENCE IS MADE ,s HE..T so.4rc T.wrc , rcEc HYclry Ex aM�.4L.O.w..OITY ,zMn a 33.e,.,,Ps coFxo TYRO HL�c HROVIoeo TO THE OWNER OR T SUPPLIED B PLANS FOR ENGINEERING OR NEMn s-,sP (MIN.DOA.ID WITH J-BOX FOR DATA AND COMMUNICATION CABLES AT RE THE PLUMBING CONTRACTOR I5 TO FURNISH AND INSTALL PRESSURE RATING of ITEMS NOT SUPPLED BY TNIMARK RFOR TRIMARK ALL PAS.DEVICE LOCATIONS.VERIFY ALL REQUIREMENTS WITH OWNER RAYGA wIu NOT ASSUME ANY REsaoxslBwn FOR TYPE VACUUM BREAKERS,BACKFLOW PREVENTERS,DOUBLE CHECK AND/OR OU.NER SELECTED VENDOR ENGINEERING THEREOF BUILDING WORK THEREOF SHALL BE 1,—' t zoe zMMn t wFaoM�TEM,e VALVE ASSEMBLIES AND REDUCED PRESSURE PRINCIPLE DEVICES. Br THE GENERAL CONTRACTOR INCLUDING ALL ROUGHING-IN D FINAL CONNECNONS AND All RUNS TO EQUIPMENT AND ta.t corvoErvs�rvc urvlT Rory rcEc Ma�lTowoc .,c MMMs oa.MPs Eb THE ELECTRICAL CONTRACTOR IA 10 FURNISH AND INSTALL 4/0 A$REQUIRED BY CODE OR GOVERNMENT AGENCIES HAVING IINicCLUDlBOR NG ALL FITTINGS OR ANY OTHER PARTY Is MAT ALSLS OR (OCTAGONAL)J-BOX WITH I/2"DIA.EMPTY CONDUIT RISER FOR JURISDICTION OF PROJECT LOCATION,UNLESS OTHERWISE SPECIFIED. LABOa OR SUCH IT WAIL GANY SUCH BE INDICATED ON THIS FIRE SUPPRESSION SYSTEM REMOTE PULLSTATIONS CONDUIT TO PUN:IF N Is NOT sPECIRCALY INDICATED ON THIS PUN,IT 2. 1EXTEND 6"ABOVE FINISHED CEILING AND REMAIN ACCESSIBLE Pb THE PLUMBING CONTRACTOR IS TO PROVIDE AND INSTALL ALL s NOT A PANT of ,TRIK RN RRYAL WILL ANDNOBE PRNIDED BY OTHERS TRIMARN REAL CO WILL ASSUME SHALL FOR FIRE SYSTEM CABLE PULLEY INSTALLATION BY KEL. WASTE LINES,BOTH DIRECT AND INDIRECT,UNLESS OTHERWISE RESPONSIBILn FOR WORK DONE V THE GENERAL CONTRACTOR OR A SUBCONTRACTOR OF THE GENERAL CONTRACTOR OR ANY u� E.9 THE ELECTRICAL CONTRACTOR 15 TO INTERLOCK EXHAUST FAN($), SPECIFIED.INDIRECT WASTE LINES ARE TO BE ADEQUATELY SIZED CHANCES MADE NECESSARY BY LOCAL CODES(INcwowc AND EXTEND FROM EQUIPMENT DRAIN TO FLOO251NK DRAIN LINES BUILDING,HEALTH DEW.ORNINANCES,TYRE DEPART.,ETC.) - - MAKE-UP AIR FAIN(5),AND INTERCONNECT MOTOR START AND STOP oR CHANCED BY THE MEN,ARCHITECT OR ANY OTHER SWITCH WITH HOOD LIGHT 5WI1CH(Sl.REFER?O ELECTRICAL AND 14.vAA. WITHIN FIXTURES MUST BE ROUTED 10 CONFORM TO INTERIOR PERSON CUTS OF TRIMARK RANAL WITH AUTHORITY To THE STRUCTURES.INDIRECT WASTE LINES FROM ICE BINS AND COLD DESIGN. THIS Pour BECOME WID UPON SUCH CHANGES AND ENGINEER DRAWINGS FOR COMPLETE EXHAUST FAN REQUIREMENTS WORK CANNOT BE COMP ErES UN L THE APPROPRIATE STORAGE ROOMS ARE TO BE INSULATED TO PROHIBIT SWEATING. CORREcnoxs THAT rRM910 O cu.uslxc THIS Pux E.IO THE ELECTRICAL CONTRACTOR 15 TO FURNISH AND INSTALL s INEDAANDNCE THAT ALL NFOHMOTHE ON THIS PUN HAS BEEN P.9 THE PLUMBING CONTRACTOR 15 TO INSTALL FIRE PROTECTION IExAMweD AND COMPARED rmH OTHER Pwrs(PLAN INTERLOCKING CONNECTION BETWEEN CONDENSATE HOOD EXHAUST FAN ARCHITECTURAL PUNS)AND ANY INCONSISTENCIES,ERRORS, TRIP,EaEaxEa AND DISH MACHINE ON/OFF CONTROLS,UNLESS OTHERWISE SPECIFIED. SYSTEM GAS SHUT-OFF VALVE FURNISHED BY KE.C.AT GAS SUPPLY AMBIGUITIES OR oMlS NS HAVE BEEN REPORTED To TRIMARK zM F-RI�ER..TEo EO�IPMErvT sT.�rvo , rcEc OorvTlry ErvT.4L oLaa� „sn M 3.4MP �� LINE TO COOKING EQUIPMENT IN AN EASILY ACCESSIBLE LOCATION RAYGM FOR I G M CORK HEREUNDER.DEN COMPLETING BIDS OR COMMENCING ANY WORK HERER.NO ADDIRONA - EJI THE ELECTRICAL CONTRACTOR TO FURNISH RELAYS FOR ANSUL SYSTEM AND PRESSURE TEST PRIOR TO CONNECTING TO ANY EQUIPMENT. AnawurBE WILL BE MADE MR SUCH WORK UNLESS IT IS - SHUT DOWN,AND HIRING AND WIRING FROM ELECTRIC FIRED COOKING ELECTRICAL PARRTSNNOT SUPPIUM WIN THE EQUIPMENT AS A _ "o EQUIPMENT RECEPTACLES AND ALL OTHER ELECTRICAL CIRCUITS RIO THE PLUMBING CONTRACTOR IS TO FURNISH AND INSTALL A GAS ETANDARD ITEM SHALL BE PRUADED BY THE PLUMBER OR z�., OourvTER TOP�R�ooLE Ma , rcEc wLO.w O�sa HaT, z°aiM as o.4MPs EO To PRo.aoE PLE�.wo OORo UNDER EXHAUST HOODS.INSTALLATION SHALL MEET ALL APPLICABLE PRESSURE REGULATING VALVE CAPABLE OF PROVIDING OUTLET ELECTRICIAN UNLESS SPECIFICALLY INDICATED ON TNs PLAIT CODES OR GOVERNMENT AGENCIES HAYING JURISDICTION OF PROJECT PRESSURE FROM 4"TO T"W5 FOR NATURAL GAS FUEL,AND 9"TO 12" El- LOCATION,SEE FIRE SYSTEM REQUIREMENT ON SHEET K-6 SERIES, LUG.FOR PROPANE GAS FUEL,WHEN SPECIFIED. MM-' AusT F� z rcEc ..000REx Ue-zaM>w-zM Ma'3 EA11 2 E.12 THE ELECTRICAL CONTRACTOR 15 i0 FURNISH AND INSTALL CONDUIT, P.II THE PLUMBING CONTRACTOR IS TO VERIFY REQ'15 FOR GREASE 09.01.2017 ® H WIRING AND INTERCONNECTIONS TO COLD STORAGE ROOM BLOWER LADEN WASTE WITH ALL LOCAL CODES AND GOVERNMENT AGENCIES _ _ COIL,50LENOID VALVE AND THERMOSTAT THRU DISCONNECT 5U11TCH HAVING JURISDICTION OF PROJECT LOCATION PRIOR 70 ❑ (SOLENOID VALVE,THERMOSTAT AND BLOWER COIL FURNISHED BY HAVING JURISDICTION OF ANY SUCH WASTE LIOCAT KE C.RUN ALL RIGID CONDUIT ABOVE COLD STORAGE ROOM CEILING ❑ a, Re sEHHResslory sysTEM , rcec ,ws�I_ R-roz weT cHeMlcvi ,zon o.o w,nH - AND PENETRATE AT CONNECTION POINT ONLY.SEE EQUIPMENT P.O2 THE MECHANICAL CONTRACTOR IS TO FURNISH AND INSTALL RELATED DETAILS ON SHEET K-6 SERIES. CONDENSER WATER SUPPLY AND RETURN IE.LABOR MATERIAL, ❑ E.13 THE ELECTRICAL CONTRACTOR 15 TO FURNISH AND INSTALL PIPING,FITTINGS,UNIONS,STRAINERS,GAUGES,VALVES,STOPS, ❑ CONDUIT AND COLOR CODED DEFROST CONTROL CIRCUIT WIRING PRESSURE REGULATORS,FINAL CONNECTIONS,AS REQUIRED �O EROVIoeo FROM FREEZER BLOWER COILS)TO TERMINAL/TIME CLOCK ON AND/OR AS NECE55ARY FOR PROPER OPERATION OF K.E.C. El REFRIGERATION COMPRESSOR RACK.REFER TO SHEET FURNISHED EQUIPMENT INSTALLATION SHALL MEET APPLICABLE .E. K-1 SERIES REFRIGERATION RACK AAIN65 FOR CONTROL CIRCUIT CODES OR GOVERNMENT AGENCIES HAVING JURISDICTION OF ❑ SCHEMATIC DETAILS. PROJECT LOCATION. E.14 THE ELECTRICAL CONTRACTOR 15 TO FURNISH AND INSTALL INTERCONNECTIONS TO KEQ.COLD STORAGE ROOM VIEWPORT 0 HEATER HIGH TEMPERATURE ALARM,LIGHTS,DOOR AND DRAINLINE HEATERS AS NECESSARY.RUN ALL RIGID CONDUIT ABOVE COLD STORAGE ROOM CEILING AND PENETRATE AT CONNECTION POINT /4JA\VWA1 \IA1LQ Q HEULE - ONLY.SEE EQUIPMENT RELATED DETAILS ON SHEET K-6 SERIES. VfWR/AL NOTES G�7 E.15 THE ELECTRICAL CONTRACTOR 15 TO FOAM SEAL ALL CONDUIT ZL _ _ PENETRATIONS THROUGH COLD STORAGE ROOM CEILING PANELS TO M.1 HVA.C.CONTRACTOR TO FURNISH,INSTALL EXHAUST,AND SUPPLY PREVENT CONDENSATION AND/OR BUILD-UP. AIR SYSTEMS IN ACCORDANCE WITH THE MECHANICAL ENGINEER 0 E.I6 THE ELECTRICAL CONTRACTOR 15 TO FURNISH AND INSTALL CONTINUOUS DRAWINGS,APPLICABLE CODES AND/OR GOVERNMENT AGENCIES 0 511 'ACE MOUNTED PLUGMOLD WITH RECEPTACLES AT 24"ON CENTER AT HAVING JURISDICTION OF PROJECT LOCATION.REFER i0 KITCHEN _ Eo ERovloeo UNDERSIDE OF BAR TOP,PROVIDE LENGTH INDICATED ON PLAN,UNLESS EQUIPMENT CONNECTION SIZE, PLANS FOR EXACT UIRECFM,STATIC PRESSURE, Q OTHERWISE SPECIFIED. DUCT CONNECTION SIZE,AND LOCATION REQUIREMENTS OF KE.C. FURNISHED EQUIPMENT. Q E,17 IT IS THE OWNERS RESPONSIBILITY TO FILE FOR AND FURNISH RECOGNIZED M.2 THE MECHANICAL CONTRACTOR 15 TO FURNISH,INSTALL COOLING TEST LAB CERTIFICATION OR CERTIFICATES OF APPROVAL,ETC.FOR WATER SUPPLY,AND RETURN SYSTEM,It.LABOR,MATERIAL,PIPING, OWNER SPECIFIED AND PROVIDED EQUIPMENT WHERE SUCH TESTING FITTINGS,UNIONS,STRAINERS,GAUGES,VALVES STOPS,PRESSURE APPROVALS ARE REQUIRED,BY PREVAILING CODES OR GOVERNMENT REGULATORS,ETC.INCLUDING FINAL EQUIPMENT CONNECTIONS AS as neREweR WITH olsHeNSER , osv e�NN TeeoiToo-N-s.s 1. 1zon a.a-1 RAF.-Reo�IReMeNTs w—a— AGENCIES HAVING JURISDICTION OVER PROJECT LOCATION. w REQUIRED AND/OR NECE55ARY FOR PROPER OPERATION OF KE.C. FURNISHED EQUIPMENT.INSTALLATION SHALL MEET ALL APPLICABLE CODES OR GOVERNMENT AGENCIES HAVING JURISDICTION OF PROJ Z)O aen E MACHINE , KEc M,w lTowoc iE-masvc vz Iw , „an ,.,unEs o w1TH LOCATION,UNLESS OTHERll15E SPECIFIED. M M co aa.= N°ENa,N.UNIT 1 KE. „sa Ma-=aMn TaHEITEM NOTE: REFER TO PLUME3ING,MECHANICAL,AND ELECTRICAL —8 w � PLANS FOR OTHER ROUGH-IN REQUIREMENTS. C J o s oROEa ERMIry os M„ a o MPs fj� Q' LL 10 s.MCFNIToa a ,osV zon a o SAPS U z m J �z2 1os.PRINTER z osV ,zM„ ao-1. LIN—MM E-1N J_ H O sz3 MPe R , — ,zMn ao Ps Lf) O N sa o.a.HOME TERM N oar zMn a.M MES TZll E-M o FOR DESIGNER: LINGLEDE6IGN INC. DRAWN: TRIMARK RAYGAL HRH cou rvTEa wR c.nsH CHECKED: TRIMARK RAYGAL SCALE: NONE - - VG JOB NUMBER: D60SO En , wE-1 EY SHEET MILE s1 HuH000<Ez, ,zMn rcw EQUIPMENT SCHEDULE N TEEa, �INGM—LE 1 MENTs wITH Hvac SHEET NUMBER FS205 az sE EIEE , Oc vErzrt-v ,iz o MECHaN Ic,u EL,w Eorz MORE OF SHEETS PLUMBING CONTRACTOR NOTES r J' ___-- I. ALL PLUMBING REQUIREMENTS INDICATED ON THIS PLAN ARE FOR KE.C.AND/OR OWNER --- SUPPLIED EQUIPMENT A$$HOWN ON SHEET F5200 EQUIPMENT PLAN AND DESCRIBED ON i-=y SHEET F5205 EQUIPMENT SCHEDULE.REFER TO THE ARCHITECTURAL PLANS AND/OR ENGINEER DRAWINGS FOR ANY ADDITIONAL PLUMBING REQUIREMENTS.ALL PLUMBING WOPAK 16" IB' O ' r " SHALL COMPLY WITH ALL APPLICABLE CODES AND/OR GOVEPoNMENT AGENCIES HAVING 4. O O q^ q^ JURISDICTION OVER PROJECT LOCATION. 2. SYMBOLS SHOWN ON TH15 PLAN INDICATES THE LOCATION,ROWH-INS,AND S1U85. QT QT PLUMBING CONTRACTOR IS 70 PROVIDE AND INSTALL ALL SUPPLIES,�1UrJ.'S,WASTE, 4 24" 24" ____ lyl Ig VENTS,AND FUEL LINE PIPING,ACCODRING i0 THE PLANS RECEIVED FROM THE PLUMBING ENGINEER AND ALSO CONFOWI G ALL APPLICABLE CODES AND/OR 4i I GOVERNMENT AGENCIES HAVING JURISDICTION OVER PROJECT LOCATION. ���1 /f��1- D/x\-� 4T 3. THE PLUMBING CONTRACTOR IS TO FURNISH AND INSTALL PLUMBING SERVICES TO l`/1 K ry,9T ry,4T _ ROUGH-IN LOCATION AND FROM ROUGH-IN TO EQUIPMENT POINT OF CONNECTION,IEMOT O❑m❑❑ 42" WATER COLD WATER,DIRECT WASTES,SANITARY DRAIN LINES,FLOOR$INK$,FLOOR R % DRAINS,STEAM SUPPLY,STEAM RETURI NATURAL GAS FUEL PIPING,FITTINGS,UNIONS, Supplies qT qT 4i STRAINERS,GAUGES,CLEAN OUTS,TRAPS,VALVES,$TOPS,PRESSURE REGULATORS ETC. FoodseCNCe Design,Equipment and Supplies II --------- - INCL -1LUDING FINAL EQUIPMENT CONNECTIONS AS REQUIRED AND/OR NECESSARY FOR 11ff - -o PROPER OPERATION OF FURNISHED EQUIPMENT.INSTALLATION SHALL MEET APPLICABLE 2 8 O 1 M C G O'� A v e n u e CODES AND/OR GOVERNMENT AGENCIES HAVING JURISDICTION OF PROJECT LOCATION. - - - v- --- Irvine, C A 9 2 6 1 4 3TJ i� II ___ ____ ______ _ 4. ALL HORIZONTAL DIMENSIONS FOR ROUGH-INS ARE FROM FINISHED WALLS AND/OR - L F a 1 2 2 949.474. 1 BUILDING GRIDLINE TO CENTERLINE OF ROUGH-IN UNLESS NOTED OTHERWISE WITHIN THIS F 0% 9 4 9.4 7 4. 1 1 2 2 - - 4'-Z' PLAN OR IN SUBSEQUENT DETAIL$.ALL VERTICAL DIMENSIONS ARE FROM FINISHED t r i In a r k u Is a,c o In 16 TO ER TO E ARCHITECTURAL PLAN AND/OR 14--- —_ 4B' q^ 4" R TO CENTERLINE OF ROU6,14-IN AS INDICATED. S. GONERNL CONTRACTOR T CONTRACTOR OCATE TH WALLS AND STRUCTURES NOT ERECTED THAT OR USED BY of Juno s io TITS aWHOLE,OF TRIM-RAYSAL AN MAY NOT BE RE PRODUCED, T TOFFICER.CHANGED Ib WJ THIS PLAN AND THE DEIGNS HEREIN IRE THE Sol£PROPS ANYCNE,IN PART OR NY 40% N. ANY LAN IN I ANTNG BY TRIMARK RAYGAL BEFORE SUCH WORK IS DONE.IT 38J - 4T 'v IS µ THE REPONSIBIHIY OF ANYONE USING THIS PION TO READ 6. THE PLUMBING CONTRACTOR 15 RE5PON518LE FOR COORDINATING ROUGH-IN PLACEMENTS D HELD E FAMIHAR WITH ALL INFORMATION SHOWN HEREON -_ -- - 4i 4T _ WITH THE REQUIREMENTS OF OTHER SUBTRADES.THE PLUMBING CONTRACTOR SHALL ALSO INCLUDING ANY EAST of NOTES.MEASUREMENTS ON THIS PUN Z3 19 Pii i9i 18" q r P.G.iQ VER FY TARE FROM-BLE INFORMATION T IMABRK RAYGAL WILL NOT NOTIFY KE.G.AND GENERAL CONTRACTOR OF ANY DEVIATION FROM INFORMATION IN THIS INFOR ON,FABRICATORS, OUR THE RS,ETOcr of SUCH A REL%I REMENT INFORMATION RABR SIBIs,coNTRACToAC ETA uOFG THIS UCH PLAN ARISING FROM FIELD CONDITIONS. PUN ARE ro CONERM ALL INFORMATION ON THIS PUN WITH N 4T qT WITH THE JOB SIR,Ill INFORMATION ON THIS PUN FOR THE I1 1. THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY THE LOCATIONS OF PLUMBING GENERA_CONTRASR)R OR THE GENERAL COU RACTOR's Y j sUBCONLRACTORS PC PERFORM LUMBING,EI£CTRII CURBS, • i �' ROUGH-INS PRIOR TO SLABS BEING POURED,WALLS OR CEILINGS CLOSED,OR ANY OTHER wnus,BUILDING OPENINGS,ETC ARE roR THE SOLD C- - WORK BEING DONE THAT WOULD IMPEDE VERIFICATION OF ACCURATE PLUMBING ROUGH-IN TO THE OF EQUIPMENT REOUIR MENLAN THE Is MADE b To THE OWNER EQUIPMENT RENT REQUk PUNS FOR ENGINEERING MA,B OR PLACEMENTS,OR THE COORDINATION REQUIREMENTS OF OTHER 5U8-TRADES,UNLE55 LISTwc OF ITEMS NOT SUPPLIED BY TRIMARK RAYGAL.TRIMARK 3'-8' OTHERWISE SPECIFIED. E ENGINES LING"rvireEor�MALLAeuILowc woRK THEREOF SHALL BE BY THE GENERAL CONTRAGTOR INCLUDING All ROUGHING-IN D FINAL CONNECTIONS AND All RUNS TO EQUIPMENT AND a 8. THE PLUMBING ENGINEER AND CONTRACTOR ARE TO VERIFY ALL REQUIREMENTS OF OWNER IN G ALL FILINGS DR ANY OTHER PARTS MATERIALS OR F 9_M q a p 062 FURNISHED EQUIPMENT WITH OWNER SELECTED VENDOR PRIOR TO UTILITY ROUGHING-INS. R�ABURRL OR SUCH.WO K IFsANY SUCH ORKITioIcn TRIMA ixls PUN;IF IT IS NOT SPECIFICALLY INDICATED ON THIS PUN,IT IS NOT A PART OF TRIMARK RAYCAL CONTRACT AND SHALL BE PRONDED BY OTHERS TRIMARN RAYGAL WILL ASSUME NO '1(1 RESPoNOBILItt FOR WORK DONE BY THE GENERAL CONTRACTOR I^� Y., OR A SUBCONTRACTOR OF THE GENERAL CONTRACTOR OR ANY U11 0 O O P.C- O G C PLUMBING ROUG"FN NOTES GLANCES MABE NECESSARY BY LOCAL CODES(INCLUDING: ILTERED WATE I UUD111 BUILDING,HEALTH DEPART.ORDINANCES,FIRE DEPART.,ETC.) O ITEM 46A OR CHANGES BY THE OWNER,ARCHITECT OR ANY OTHER 3 - PERSON oumDE of TRIMARK renrcu WITH wnHoam To THE WGIRKNeumo:PLAN BECOME UPON APPROPRUTEc[s AND 5 46 O P.C.TO PROVIDE WATER,GAS AND DRAIN CONNECTIONS FOR WATER HEATER IGORRECToxs ARE MADE BY TRIHARK RA—USING THIS PUN ITEM 09.SEE PLUMBING ENGINEER DRAWINGS FOR ROUGH-IN REQUIREMENTS, EEGAMIIHED AND THAT ED eml OTHER ON THIS U: BEEN ARCHITECTURAL IMBICAMBIGUITIESES OR OMISSIONS HAVE BEEN REPORTED TO TRIMARN PUNS)PND ANY INCONSISTENCIES,ERRORS, P.G.TO CONNECT FILTERED WATER OUTPUT FROM WATER FILTER ITEM 10 i0 ROUGH-IN RAYGa FOR WRITTEN CDORECTIONS BEFORE COMPLETING BIGI E1 POINTS SHOWN.VERIFY REQUIREMENTS OF NON-KEC PROVIDED EQUIPMENT WITH uiNCEu Y HEREUNDER.a°UNLSI ALLOWANCE MR ESS I IS PLUMBING 5UFPLIER.DRAIN LINES MUST HAVE A 1-1/2"DROP PER 5'OF RUN(2.5 CM PER METER), AGREED BEFORE xemPTANCE OF BIDS.i THE R u A N—WALL PLUNBNG AND MUST NOT CREATE TRAPS.THE FLOOR DRAIN MUST BE LARGE ENOUGH 1O STANDARD ITEM SHALL BE PRUADED BY THE PLUMBER OR ACCOMODA7E DRAINAGE FROM ALL DRAINS.RUN SEPARATE BIN AND ICE MACHINE ELECTRICIAN UNLESS SPECIFICALLY INDICATED ON TNs PLAN, DRAIN LINES.INSULATE THEM TO PREVENT CONDENSATION.VENT THE BIN AND ICE ❑ MACHINE DRAIN TO THE ATMOSPHERE.THE ICE MACHINE DRAIN REQUIRES AN IS" VENT.DO NOT VENT THE CONDESNER DRAIN ON WATER-COOLED MODELS.DRAINS 09.01.2017 N N MUST HAVE A UNION OR OTHER SUITABLE MEANS 70 ALLOW IN PLACE DISCONNECTION ❑ r - 131 137 FROM ICE MACHINE WHEN SERVING 15 REQUIRED.BASE DRAIN-U5E l--CPVC TUBING w i b'-9" 13'-Z' AND SILICONE SEALANT TO CONNECT TO THIS OPTIONAL DRAIN. ❑ ----- O P.C.TO PROVIDE AN APPROVED BACK FLOW PREVENTION DEVICE FOR JANITOR ❑ _ FAUCET ITEM 062. P.G.TO VERIFY JANITOR DRAIN REQUIREMENT WITH G.G. - _ 42" D P.G.TO PROVIDE ALL FLOOR AREA DRAINS AS SHOWN,LOCATIONS AND DETAILS - --.- I I I O SHOULD BE COORDINATED WITH PLUMBING ENGINEER PLAN SHEET P220. ❑ qT_ aT I,�� 4T 4T 4T O G02 FILL STATION ITEM 08.BY P.G.P.G.i0 VERIFY THE EXACT LOCATION WITH G.G. p4T 4" 24" 56 ` --- i � 0 i� CO2 CONDUIT FROM FILL STATION ITEM 08.1 i0 BULK G02 TANK BY P.G.P.G.i0 VERIFY 4T i0, L 14 x. I a EI CONDUIT ROUTING WITH G.C. 4T 4T --i SLEEVE BY - SLEEVE BY -PT- F P.G.TO PROVIDE GAS SHUT-OFF COCK IN-LINE BEFORE INSTALLING KEG-SUPPLIED IL _ 36' ,� O ELECTRICAL SHUT-OFF VALVE FOR HOOD FIRE PROTECTION SYSTEM BELOW CEILING Q e i IN AN ACCE6515LE AREA.SEE MECHANICAL ENGINEER DRAWINGS FOR ADDITIONAL I I i 4T ti L_4L 4T INFORMATION. IPO.TO- - - F P PLUMBINGRAND MECHANICAL ENGINEERENG NEER DRAWINGSFFOGR ADDITBIONAL TNFORMA710N. Q b P.G.70 PROVIDE GOLD WATER ON ROOF FOR MAKE UP AIR FAN ITEM 303.SEE 1Z --------- ------ L' � i i PLUMBING AND MECHANICAL ENGINEER DRAWINGS FOR ADDITIONAL INFORMATION lQjO P.C.i0 CONNECT KITCHEN GREASE WASTE i0 GREASE INTERCEPTOR - - - - - $ 4'-10' 5'-5' I i - K 141 Z2 NOT USED. Lij Ib 5==(�I ------------ -------- ,c 48" 54" O P.G.TO PROVIDE COLD WATER CONNECTION TO WATER FILTER, Q W ___J III III yII _ J - 4T SODA LINE CONDUIT AS SPECIFIED BY OWNER VENDOR AND PROVIDED BY P.C. -�__________ 18" 43' 4T 4T M VERIFY CONDUIT ROUTING WITH OWNER VENDOR. wco /! I �_ 4T Lu Y� � 0 0 PLUMBING ROUGFFN SYMBOLS ■� � � � (n J J o O 42" - - F ►+ GOLD WATER �� LLL 9 ►BF COLD WATER(FILTERED) QT 2 Z ►r HOT WATER(SEE SCHEDULE FOR REQUIRED TEMPERATURE) Lj b m _ 14( HOi MID COLD WATER(4"APART)06 CI HOi MID GOLDWATER(8"APART) LL O 4- GAS LINE(QUICK DISCONNECT NOT REQUIRED) L(D O N GAS LINE(WITH QUICK DISCONNECT) �p -^ p� PLAN �� C. DIRECT WASTE(WALL) UNDERGROUND PLUMBING PLAN o DIRECT WASTE(FLOOR) DESIGNER: LINGLEDESIGN INC. y POINT OF CONNECTION(APPROX.) DRAWN: TRIMARK RAYGAL MAX MJM UTI ITY IN T OFFSET OUT �Wl4LL JZ CO2 FILL STATION B7 GC.VERIFY LOCATION AND INFORMATION WITH CHECKED: TRIMARK RAYGAL FACE OF BUILDING WALL _ __ PLUMBING ENGINEER PLANS, SCALE: UTIY IN IT _ r ® FLOORSINK(WITH 2"DIAL WASTE AND 1/2,3/4 OR FULL GRATE AS QUICK DISCONNECT HOSE INDICATED,UNLESS OTHEF U15E SPECIFIED). JOB NUMBER: 58080 ASSEMBLY WITH DOABLE L L L T FOOD SERVICE SWIVEL ELBOWS AND SHUT-OF C---_Fr--_I:ui: FLOOR DRAIN BY G.G.(SHOWN IN THE PLAN ARE FOR REFERENCE ONLY,VERIFY SHEET TRLE COOKING EQUIPMENT �Q VALVES PROVIDED BY KE.C. _ - ,__ ® PLUMBING ENGINEER DRAWINGS FOR EXACT LOCATIONS). PLUMBING PLAN �+ AND INSTALLED BY P.C. FOOD SERVICE !K COOKNG EGIIIFhIENT � 4 � ELECTRIC OR MECHANICAL SOLENOID GAS SHUT-OFF VALVE DIRECT CONNECTION FROM ROUGH-IN 70 EQUIPMENT'S POINT OF CONNECTION 303 -I INDIRECT WASTE CONNECTION FROM EQUIPMENT TO FLOORSINK M SHEET NUMBER ELEVATION RESTRAINING CABLE A -PLAN 0 SODA CONDUIT BY P.C.VERIFY REQUIREMENT WITH OWNER SELECTED VENDOR BY KE.0 G02 CO2 CONDUIT BY P.G.VERIFY REQUIREMENT WITH OWNER SELECTED VENDOR F5�1 GAS QUM DISCONNECT DETAIL 5 C A L E 1 ROOF MOUNTED MAi�� AR SYSTEM GREASE INTERCEPTOR N. OF SHEETS ELECTRICAL CONTRACTOR NOTES I. ALL ELECTRICAL REQUIREMENTS INDICATED ON THIS PLAN ARE FOR OWNER AND KEG. SUPPLIED EQUIPMENT SHOWN ON SHEET K-I EQUIPMENT PLAN AND DESCRIBED ON SHEET K-2 EQUIPMENT SCHEDULE REFER TO THE OWNER,GENERAL CONTRACTOR, ARCHITECTURAL AND ENGINEER PLAN FOR ADDITIONAL INFORMATION.ALL ELECTRICAL REQUIREMENTS.ALL ELECTRICAL WORK SHALL COMPLY WITH APPLICABLE CODES AND/OR GOVERNMENT AGENCIES HAVING JURISDICTION OVER PROJECT LOCATION. 2. THE SYMBOLS SHOWN ON THIS PLAN ONLY INDICATES THE LOCATION,ROUGH-IN,AND CONNECTION.THE ELECTRICAL CONTRACTOR IS TO PROVIDE AND INSTALL CIRCUITS AND CONDUIT RJN5 A$REQUIRED,IN ACCORDANCE TO THE ELECTRICAL ENGINEER DRAWINGS, CONFORMING WITH ALL APPLICABLE CODES AND/OR GOVERNMENT AGENCIES HAVING JURISDICTION OVER PROJECT LOCATION. TriMark 3. THE ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL ELECTRICAL SERVICES TO ROUGH-IN LOCATIONS AND FROM ROUGH-IN TO EQUIPMENT POINT OF CONNECTION,IE:LABOR,MATERIAL,WIRING,SERVICE FITTINGS,CONDUITS,CIRCUIT BREAKERS,JUNCTION R Jm❑❑ BOXES,OUTLETS,PLUG-MOLDS,SWITCHES,FULL-BOXES,CONTROLS,SHUNT-TRIPS,NEMA 1� CONNECTORS AND CONFIGURATIONS,LOCK-OUT DEVICES,DISCONNECTS,PANEL BOARDS, Food$erNce Deso,fl uipment and kppks ETC.NCLUDING FINAL EQUIPMENT CONNECTIONS,AS REQUIRED AND NECESSARY FOR 11II FROPER OPERATION OF FURNISHED EQUIPMENT.INSTALLATION SHALL MEET APPLICABLE 2 6 0 1 M C Yi 0'� A v e n u e CODES AND/OR GOVERNMENT AGENCIES HAVING JURISDICTION OF PROJECT LOCATION. I ry i n e, CA 9 261 4 4, THE ELECTRICAL ENGINEER AND CONTRACTOR ARE TO VERIFY ALL REQUIREMENTS T e l 9 4 9 .4 7 4. 1 0 0 0 AND LOCATION OF OWNER FURNISHED EQUIPMENT WITH OWNER SELECTED SUPPLIER F o x 9 4 9.4 7 4. 1 1 2 2 PRIOR 70 ROUGHING-IN ANY UTILITIES. �'�',{r I In 0 r k U S 0,C o In 5. ALL HORIZONTAL DIMENSIONS FOR ROUGH-INS ARE FROM FINISHED WALLS AND/OR THIS PUN AND THE DESIGNS HEREIN ARE THE SOLE PROPERTY 52J 522 52J 52J 54 BUILDING GRIDLINE TO CENTERLINE OF ROUGHNN UNLESS NOTED OTHERWISE WITHIN OF FRIMASK FAECAL AND MAY NOT BE REPRODUCED,CHARGED THESE PLANS OR IN SUBSEQUENT DETAILS.ALL VERTICAL DIMEN510J5 ARE FROM wemEe°PFexiSSSI°ON OF APTRIMA°RK WHILE,WITHOUT COMPANY OFFICER. 2'-b' I'-II" I'-6' I'-I' FINISHED FLOOR TO CENTERLINE OF ROUGH-IN,AS INDICATED. H RL RAYGAL BEFORE IA's'DONE°R ISRTE RESPONSIBIn OF R THIS FLAN i0 REOD AND BEGONE FAMILIAR WITH ALL INFORMATION SHOWN HEREON 6. IT 15 THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO COORDINATE THE IUSLU ING ANY UST IF NOTES.MEASUREMENTS ON THN PUN PLACEMENT OF ELECTRICAL ROUGH-IN5 WITH THE REQUIREMENTS OF THE OTHER E ME A AVN0,LE INFORMATION TRIMARK RAvcx WILL NIT ASSUME ANY RESPONSIBILItt FOR THE ACCURACY of SUCH SUB'TRADES ELECTRICAL CONTRACTOR SHALL AL50 NOTIFY THE KE.C.AND INFORMATION,FrsRl'11,coNnu�T I ETc GINS THIS GENERAL CONTRACTOR OF ANY DEVIATIONS FROM INFORMATION IN THESE PLANS ni"OLIFRNTHwiIUWR THE JOB SITE.&IIOMBREN ON P FORTHHE ARISING FROM FIELD CONDITIONS. GENER&CONTRACTIR OR THE GENERAL CONTRACTORS r - SUBCONTRACTORS TO PERFORM(PLUMBING.ELECTRIC&,CURBS, 02 22 S,BUILDING OPENINGS,ETC.ARE FOR THE BOLL 24' — ' -_ = N- IT 15 THE RE5PON51BILITY OF THE GENERAL CONTRACTOR TO VERIFY THE LOCATION PURPOSE OF EQUIPMENT REOUIR MENTS;REFERENCE IS MADE L J _ 3'-9' 6'-I' TO THE OWNER OR ARCHITECTURAL PLANS FOR ENGINEERING OR OF ELECTRICAL ROUGH-INS PRIOR TO THE SLABS BEING POURED,WALLS,CEILINGS SrwG OF ITEMS NOT SUPPLED BY TRIMARK FAECAL.TIiINARK WILL NOT ASSUME ANY RESPONSIBNIY FOR _ CLOSED,OR ANY OTHER WORK BEING DONE THAT WOULD IMPEDE VERIFICATION OF ENGINEERING THEREOF ALL BUILDING MRK THEREOF SHALL BE O ] 45J I`_-_y- Ai REQUIREMENTS OF PLACEMENT OF ELECTRICAL UNLESS OTHERWISE SPEORDENDAiION OF THE ILBBOR FOR SU GENERAL WORK.IFC ANY OTHER PARTS MY SUCH WORKK I ICNCTIONS AND&L RUNS TO ERP%K THE BY THE CONTRACTOR INCLUDING All ROUGHING-IN NGN R ANY SUCH WORK IS A ND 5 q q' PUN,F IIrNTRACOT E ALL SPEGFlC&LY BE INDTMTED ON THIS I DIt 4 - PROApED BY OTHERS TRIM4RN RAYGLL WILL ASSUME NO BE ELECTRICAL ROUGii—N NOTES REIPONSIBILtt FOR WORK HONE BY THE GENERAL CONTR CTOR -- -' JT T -i q7 OR A SUBCONTRACTOR OF THE LOCAL C DES(INCLUDING: OR ANY CHANGES HEAL NECESSARY O LOCAL CODES(INCLUOINC: �i BUILDING,HEALTH DEPART.ORDINANCES HRE DEPART,ELC) o `qT 24 [——_�— --- I F I I 18- ;9 oR CHANGES BY THE OwxEre,ArecH FEET oR ANY oTLicR PERSON DO slDvwi liEcouEs v"ADioAL WIN AITRHoam TO THE 26 21 I'-1' " 31 I I I = ESICN. UPON SUCH CHARGES AND TO ITEMS 84 O E.C.10 PROVIDE 4 JUNCTION BOXES:2 FOR DATA AND 2 FOR POUTER WORK CARNGT BE COMPLETED UNTIL THE APPROPRIATE 9 I I I / \ I I A CORRECTIONS ARE MADE BY TRIMARK RAYGAL USING THIS PLAN IN 4 2'-8. J,30J,3O K qr SEE ARCHITECTURAL AND ELECTRICAL ENGINEER DRAWING FOR MORE INFORMATION. Is ADMITTANCE THAT ALL INFORMATION ON THIS PLAN HAM BEEN 4T 4T L-- 64 - EXAMINED AND COMPARED WITH OTHER PIONS(ENAMPLE: U 42" 9 PRCHRECTUR&PUNS)AFD ANY INCONSISTENCIES,ERRORS, AMBIGUITES OR OMISSIONS RAVE BEEN REPORTED TO TRIMARK Y O R1YC11 FOR WRITTEN CORRECTIONS BEFORE CONPLETNG BIDS E.G.10 VERIFY ALL P.OS.SYSTEM REQUIREMENTS WITH OWNER VENDOR. OR COMMENCING EANY WORK HEREUNDER.NO ADDITION& '9 qT aT qT 6 REFER TO ARCHITECTURAL AND ELECTRICAL ENGINEER DRAWINGS FOR ALLOWANCE ALL eE MADE FOR SUCH WORK UNLESS IT IS AGREED BEFORE ACCFPTARCE OF BIDS.PLUMBING OR II ----- LOCATION AND MOUNTING HEIGHTS OF P.O.S.AND MICROPHONE ROUGH-INS ELECTRICAL PARrs xoT SUPPLIED AN THE EQUIPMENT AS A - T ry ry DR ON MILLWORK COUNTER, ELECTRICIAN STANDARD UNLESS 17MLSEr cRC&Y�iN INDICATED ON BY THENTHISre PUN. NOT USED _ OE.C.TO PROVIDE AND INSTALL INTERCONNECTING DEFROST CIRCUIT WIRING 09.0{23{7 ® DEP FROM FREEZER EVAPORATOR COIL(ITEM 01 TO REMOTE CONDENSER 12 - 6 )ITEM 01.1)ON ROOF. ❑ 39 I'-8' 1'-4' 9' I'-IO' I'-5" < NOT USED El qa' 4B' sq" NOT O V EXACT LOCATION. ❑ W. o FO FIRE SYSTEM PULL STATION BY E.C.CONFIRM LOCATION WITH FIRE MARSHALL I ;n - -v NT EC TO VERIFY EXACT ❑ All------- 4T 4T ROUGH- 8 A68 STUB s r 1e Na WITH ELECTRICAL OG NOT USED ❑ 41 A68 _ D l'--\ ENGINEERING PLANS. ar Nr \ 09 O EL,TO VERIFY WATER HEATER ELECTRICAL REQUIREMENTS WITH G.C. ❑ L 0 A _ - O REFER TO ELECTRICAL ENGINEER DRAWING FOR MANAGERS OFFICE POWER .�, I AND DATA REQUIREMENTS. Q Tr— G EL,TO INTERCONNECT PREWIRE PACKAGE(ITEM 302)WITH TWO EXHAUST FANS O (ITEM 30.1)AND MAKE-UP AIR FAN(ITEM 303). REFER TO EXHAUST HOOD ZL o 5'tJ Y"a f'- I - - SHOP DRAWINGS AND EXHAUST SYSTEM DETAILS FOR WIRING CONNECTION Q ^y 512 Nr REQUIREMENTS. MOUNTED INSIDE THE CABINET, l ,� K K K gEY O EL,10 INTERCONNECT ICE MACHINE(ITEM 46.0 WITH REMOTE CONDENSER SEE ARCHTECNRAL AND Y fll y • • • (ITEM 462)ON ROOF. Q ELECTRICAL PLANS FOR MORE DETAILS- � _ 0 M E.G.TO REFER ARCHITECTURAL ROOF PLANS FOR REMOTE CONDENSER Q 2'-0' 3ITO' Z d 4 o� O LOCATIONS. Q 45 45J 46 46J 68 0 1 O 30J 0 `� EL,TO CONNECT AIR CURTAIN THROUGH DOOR ACTIVATED MICR05WITCH. i0 MOUNT P TCH POCKETS DED BY GL. TENS 4IT AND 46J L OO E.C.TO REFER i0 MECHANICAL ROOF PLANS FOR EXHAUST SYSTEM LOCATIONS. {J,J ASIDE ITEM 43 AT ENGINE LOCATION ELECTRICAL AN ENGINEER ROOF TTP. M ROOF MOUNTED EXHAUST FANS ELECTRICAL ROUGH—IN SYMBOLS � w WALL'MOUNTED SINGLE PURPOSE RECEPTACLE r u le (FLUSH WITH FINISHED WALL) _ -—- FLUSHWALL- WITH FIN DOUBLE PURPOSE RECEPTACLE co _j � (FLUSH WITH FINISHED WALL) � (n J IYm WALL-MOUNTED JUNCTION BOX(FLUSH WITH FINISHED WALL) d� w < (2) WATERPROOF JUNCTION BOX. •iLi • CONDUIT STUB OR POWER STUB m c�c z ~ P TCH POCKET Try ELECTRICAL POWER WHIP WITH 6-FOOT LONG LEAD(NO J-BOX1 J K PROVIDED BY GC. J VUV R� DROP CORD(FROM CEILING TO 6 TENT ABOVE FINISHED FLOOR) VERIFY LOCATION LL WITH ELECTRICAL COLOR CODED DEFROST SYSTEM CIRCUIT WIRING O 303 O ENGINEERING PLANS (FROM REMOTE REFRIGERATION RACK LOCATION) Lf)O JVW~ DOOR JAMB HEATER(COMPONENT BY KE.C.) N M IOU+ ELECTRICAL POWER SWITCH, TEMPERATURE ALARM(COMPONENT BY KEL) ROOF MOUVTEO MAM—W AR SYSTEM -4 DESIGNER: LINGLEDESIGN INC. TELEPHONE OUTLET DRAWN: ?RIMARK FAECAL W-0 4/0 OCTAGONAL J-BOX(FLUSH WITH FINISHED WALL) CHECKED: TRIMARK RAMGAL EMPTY CONDUIT FOR COMMUNICATION CABLING (VERIFY POINT OF ORIGIN WITH ARCHITECT) SCALE: ELECTRICAL EXTENSION JOB NUMBER: 58080 (FROM ROUGH-IN TO EQUIPMENT POINT OF CONNECTION) Ld A I Yj j - SHEET TITLE H WATERPROOF FIXTURE MOUNTED SINGLE PURPOSE RECEPTACLE. ELECTRICAL PLAN JD PITCH P �c WATERPROOF FIXTURE MOUNTED DOUBLE PURPOSE RECEPTACLE. L IBY PROVIDED BY GC. L3L WATERPROOF FIXTURE MOUNTED JUNCTION BOX, 16J 462 01 01J VERIFY LOCATION ----- PRE-WIRED EQUIPMENT TO J-BOX AND/OR 6J5-PANEL BY KE.C. M WITH ELECTRICAL I ENGINEERING PLANS VAPOR PROOF LIGHT FIXTURE(COMPONENT BY KE.C.,LIGHT BY E.C) SHEET NUMBER CONVENIENCE OUTLET AT 120/1 15.0 AMP.CIRCUIT ROOF NTED CONDENSERS FP FIRE FULL-VERIFY WITH ELECTRICAL AND MECHANICAL PLANS FS2 2 0 OF SHEETS GENERAL CONTRACTOR NOTES I-E I-E I-E I. THE GENERAL CONTRACTOR IS TO FURBISH AND INSTALL THE FOLLOWING ITEMS INDICATED ON THIS PLANS,UNLESS OTHERWISE SPECIFIED: I-A I'-5"I'-0"I'-5" I'-5' I-E •ALL REINFORCING WALL-BACKING,UNLESS OTHERWISE SPECIFIED. •WALL-BUMPER GUARDS,RAILINGS AND POSTS •BACKING,BEAMS TRUSSES OR OTHER SUPPORT MEMBERS.ALSO FOR THE COMPONENTS OF SUPPORTING THE EXHAUST HOODS AND OTHER CEILING MOUNTED EQUIPMENTS NOTED. 2'-2" 2'_0" 2. ALL DIMENSIONS SHOWN ON THIS SHEET ARE FROM FINISHED WALLS,FLOORS AND/OR BUILDING GRIDLINES.INCLUDE ALLOWANCE FOR i141CKNE55 OF FINISH MATERIALS. ���� /r��l— o --- - --- Lvl K 3. THE GENERAL CONTRACTOR E UI FURBISH A CONNECTION AND SE ACCESS TO EQUIPMENT ❑m❑❑ IB' IB' O INSTALLATION AREAS THAT REQUIRES CO ES ANON AND VEIFNMEES ABOVE FINISHED 3• q° O II � 36° 42° 4" CEILING,IN ACCORDANCE i0 LOCAL CODES M1D/OR GOVERBMENi AGENCIES HAVING I I N _ • __ __ JURISDICTION OF PROJECT LOCATION. M — ____ Foodsernice Design,Equipment and Supplies --J4T T � I I I I I 4T 4i 4T 24' 24" .�---- ❑ 18" 4. THE GENERAL CONTRACTOR IS TO PROVIDE AND INSTALL ALL PENETRATIONS THRU 4T 0" 4'-I' 9'-4" F CEILINGS,ROOFS AND WALLS FOR DUCTS,ETC.INCLUDING DUCT SHAFT WRAPPINGS, 11ff IiI I I ENCLOSURES,FIRE SEPARATIONS ETC.AS REQUIRED.IN ACCORDANCE TO LOCAL MUD 2 S O 1 M C G 0'� A v e n u e I-A I-E -A I-J —x�. 4T FIRE DEPARTMENT CODES AND/OR GOVER4'MENT AGENCIES HAVING JURISDICTION I r v i n e, C A 9 2 6 1 4 4T 4T �__� - - - - OVER PROJECT LOCATION. T e l 9 4 9.4 7 4. 1 0 0 0 Fax 949.474. 1122 — , 5. 114E GENERAL CONTRACTOR SHALL SOUND PROOF COMMON WALLS WHERE N015E OR W W W,{r i In a r k u s a,c o In VIBRATION PRODUCING EQUIPMENT IS LOCATED ADJACENT TO DINING AREAS.SEE 4T 4i 4T ARCHITECTURAL PLANS FOR LOCATIONS AND ADDITIONAL INFORMATION, THIS I WI AND ME DESIGNS HEREIN IRE THE 501E PROPERTY Or L SAL DIMENSION SYMBOLS GRIM PERMISSIONYYONE,D MAY NOT BE REPRODUCED,CRINGED RK R I D BY AN N PAR OR WHOLE WRHO R ME S.RYED LEAAR US TO THIS PLAN MUST BE PER MARK BEFOR SUCH WORK IS NE USING THIS PLAN TO _ IA �".• m __ NOT 4-1.___ ON INCL ARE DING ANAND BECOMEa ME ANY w�BioRu ary MEASURTHIMANEMENTS TSONTHIS INFORMAL10N SHOWN Prop NON-COMBaST BLE WALL BY GC. ASSITY R THE ACCURACY OF SUCH INFORAURON FABRICATORS,CONTRACTORS,ETC USING THIS PLAN LoeESi GADD IN�FORRMA ALL non INFORMATION NIS ON IFORR�THE H ME"THE SOLD 'ii.�liii _ o C �" 6.4' TOYITG4 OF IT EQUIPMENT PMENMREQU rMEIN Nss eRiu"nRENCEIS WALL BACKING GENERAL CONTRACTOR OR THE GENERAL CONTRACTORS ANY — -- _ 4T GENERAL REQUIREMENTS INDICATED 1 T HOOD E16 SUPPORT INSTALL ALL THIS OFLANI AND LIST ev 01uL GENERAL CONTRACTOR TANOR ai eurvs Ta Eo�ipME NTRAMORRI TY RE SIDES .cases, M DE OR SHOWN AN 7 INEERING OR o RIMMK RK THEREOF SHALL s '9 16 4 4T r 4T (UNLESS OTHERWISE NOTED) INCLUDING ALL FITTINGS DR ANY OTHER PARTS MATwiALS AND E LABOR FOR SUCH WORK.IF ANY SUCH WORK Is IN TRIMARK CONTRACT,IT WLL I SPECIUCALLY BE NDIGTED ON THIS PLAN;IF IT IS NOT SPER—LY INDICATED ON THIS PLAN,IT 4T q ^ Is NOT A PART OF TRIMARK RAYCAL COURRACT AND SHNL BE PRONGED BY OTHERS TRIMARN RAYGAL WILL ASSUME NO - ---- - �� RESPoNSIBILItt FOR WORK DONE BY THE GENERAL CONTRACTOR OR A SUBCONTRACTOR OF THE GENERAL CONTRACTOR OR ANY I-D CHANGES MADE BECEAIRY BY LOCAL CODES(INCLUDING: S'-b' BUILDING,HEALTH DEPART.ORDINANCES,FIRE DEPART.,ETC.) 5'•Z' S'•0' OR CHANGES SY THE OWNER,ARCHITECT OR ANY OTHER - d PERSON THIS P of TRIMABECOME K RAYGAL WITON UCH RRYCHANGES E ME 42' WORKNCANNOT BECOMPLETED NITIL THHEENAPPROPRUTECES AND a yy CORRECTIONS ARE MADE IN TRMATIO RAYGII.USING THIS PUN 15 AS M EGANINEDANCE THAT ALL AND COMPARED WTTHMOOTHER ON THIS BEEN 4T ARCHITECTURAL PUNS)PNO ANY INCONSISTENCIES,ERRORS, IMBICUITIEl OR OMISSIONS NAME BEEN REPORTED TO TRIMVM OR C CO FOR WRITTEN CORRECTIONS BEFORE COMPLETING BIDS ALLOWAR�I OR OMMENCING ANY WORK HEREUNDER.NO AGDIRON4 AGREED BEFORE ACCEPTANI WILL BE-1 CE OFWIN THR SUCH E EQUIPMEK UNLESSNT IT IS I ItrCl all ELECTRICAL PARTS NOT SUPPUED D B ME EDUIPMER AS A SinrvDIRO ITEM SHALL BE PRONGED BY 114E PLUMBER OR ELECTRICUN UNLESS SPECIFICALLY INDICATED ON MIS PLAN. El w� 09.01.2017 ® H AIER FL79i MIMI ❑ WALL—BACKINGEl ❑ 0 0 0 L�I O I 11`l 42' O RR NK MFA NOIb IMY F LOW WALL4=4 'yL- __ — ZL - -JT 1`--� m 4T 4T 4T e I I I III 4i I 11 4'CURB W I I I x ` ' II 5'-11° �I �� 4T � � 4T 4T L--t __- __-__- _ --- — —I 42. L O 00 (h w 0 r J r cr ILL. I I --- _6 d 4 4' O MOVE SAC M M GINM (4) SE OUA �1 � u' 48" w'-o m � — T^ --1 IIi Fes_ -__ P 9 IB" 48" I 4I: �4i qi O .TO PROUD 4 HIGH CURB T 4'-0' O B�E LEVELED WITH POUND EPDXY WITH DESIGNER: LINGLEDEBIGN INC. /8'CAVED BASE SMOOTH AND LEVEL - 1 PORT FINISH AND ADJACENT - 4T `u n DRAWN: TRIMARK RAYGAL HOOD SUPPORT L � SEE SHOP DRAWINGS FOR ,I` , CHECKED: TRIMAW RAYGAL ORE INFORMATIQN. 'I I :9 III o — SCALE: JOB NUMBER: 56080 :.K AWL SYM I..L MWM OM SHEET TITLE BUILDING CONDITIONS: NOTES: WALL-BACKING,CURB,4 OALL WALL-BACKING TO BE Ib GAUGE GALVANIZED,SECURELY ATTACHED TO STUD HOOD-SUPPORT PLAN AND WALL FRAMING. OWALL-BACKING LENGTH SHOWN ON BUILDING WORK REQUIREMENTS ARE MIN., ALWAYS EXTEND TO NEXT STUD OVER IN EACH DIRECTION. SHEET NUMBER OALL WORK SHOWN TO BE BY G.C.UNLESS OTHERWISE NOTED.SCALE FS2 30 CURB AND HOOD—SUPPORT WALL—BACKING DETAIL NTH 1 OF SHEETS ITEM 46J —r ICE MAC14M �7 105w+ ITEM 45 TEA BREWER (BY OLLNEI� TriMark ITEM 41 ITEM A ITEM 45J S/S BAR WITH JUICE DISPENSER R❑m❑❑ ITEM 52 KETCHUP SNEEZE GUARD DISPENSER 0 0 .=—_. P05 ORDER DISPENSER (BY OWNER) (BY 01 TERMINAL (BY OWNER) 0 j !i Foodser6ce Design,Equipment and Supplies (BY OMER) ITEM 51 I _ FM-rrmI 1f CASHIER/ TENT Q� p I Ijj l 2 8 0 1 M C G a W A v e In e PI 2614 ER TRASH —._._. ��CHUTE TeY11ne, CA 949,474. 1000 (TYPICAL) _._._. F a x 9 4 9.4 7 4. 1 1 2 2 triInarkusa,coIn r , r THIS PIAN AND THE DESIGNS HEREIN ARE THE SOLD PROPERTY OF OR USIED BYBAYGAL ADD RNYONE,IN PARTNOT BE REPRODUCED OR WHOLE,WITHOUT THEANGED I wRITTNry ANYNEED RMISSION BEGAN US TO TILL PLAN MUST BE P APPPoVEDE IN LUNG By IS THEPER IT PON56wY ANYONER SUCH USING THIS PLAORK N DO DONE ANDINCLUDECOME NG ANY LIST O W ITH OF NOTES HEREON INFORMALLON SHOWN MEASUREMENTS ON THIS PLAN ARE FROM AVNUBLE INFORMATION,IRIMVM RA—WILL NOi ASSUME ANY RESPoNSIBILItt FOR THE ACCURACY OF SUCH INFORMATION.FABRICATORS,CONTRACTORS,ETC.USING THIS PLAN ARE To DOW M ALL INFORMATION ON THIS P WIN.AN W ITEM 48 ITEM 4S ITEM 44 ITEM 46 THE ROB SITE ILL INFORMAFON ON THIS PUN FOR THE GENERAL CONTRACTOR OR THE GENERAL CONTRACTOR'S TRASH TRASH CONDIMENT ICE AND BEVERAGE SUBCONTRAcr0R5 TO PERFORM C LAMBING,SIDES .1,CURBS, WALLS,BUILDING OPENING$ETC.(ARE FOR THE SOLD CONTAINER CONTAINER DISPENSER DISPENSER PURPOSE OF EODIPMENT REQUIR MENTS; THE IS MADE (BY OWNER) (BY OWNER) (BY OWNER) (BY OWNER) LISTNG OF ITEMS OR CSHUPv`LLiEo BYPTLANS reFO ENGINEERINGROR RAYGLL WILL NOT ASSUME ANY RESPONSIBILITY FOR ENGINEERING THEREOF.ALL BUILDING WORK THEREOF SHALL BE BY THE GENERAL CONTRACT`INCWDING All ROUGHING-IN AND FINAL CONNECTIONS AND All RUNS TO EQUIPMENT AND INCLUDING ALL FITTINGS OR ANY OTHER PARTS MATERIALS OR LABOR FOR SUCH WORK.IF ANY SUCH WORK IS IN TRIMARK � Q� C�e ��I � ��I��� 1 �_��I I�Q CA 8 C A L E PRinN iFC IT ONTF-'IT WILD SPECTURocp Eli INDICATED OONJ THIS ELEVATION - BEVY AGE MIN TM Y■ I VW D ■ mx-VI co W Y\ AREA 1/2°-1 L E � PRIDED BY OTHER S I TFIRMARN AYGAT WILL ASSUME THIS PLAN BE RESPoNSIBILItt FOR WORK DONE BY THE GENERAL CONTRACTOR r - OR A SUBCONTRACTOR OF THE GENERAL CONTRACTOR OR ANY NECESSARY—CHANGES MADE BY LOCAL ODES BUILDING,HEALTH D ORDNAry ESC FIRE DEP-INETC.) OR CHANGES SY THE OWNER,ARCHNECT OR ANY OTHER L J PERSON OUICI E OF TRIMARK RAYGAL WITH AUTHORDY TO THE DESIGN. THIS B BECOME VOID UPON SUCH CHANCES AND O y_-- -- GO RECTIONK ARE MADE BY MAR CANNOT IRK E COMPLETED R USING UN WE TIL PUN S ASMIiTANCE THAT ALL INFORMATION ON THIS P.AN HAS BEEN EXAMINED AND COMPARED-OTHER PLANS(ExAAIBE: MDDI IEURAL PUNS)NI Mtt INCONSISTENCIES,ERRORS, IMBICUIT0 W OMISSIONS HAVE BEEN REPORTED TO TRI BIDS 36" 4Y 4Y' OR CO FOR COMMENCING AN CORRECTIONS BEFORE COMPLETING BIDS _ 4" - OR COMMENCING ANY WORK HEREUNDER.NO UNLESS AGREED BE WILL BE MADE FOR SUCH WORK UNLESS R IS _ AGREED BEFORE ACCEPTANCE OF BIOS.PLUMBING OR 4T 4T 4T �OF SOFFIT STANDARD PARTS NOT SUPPLIED WM THE EDU PMENT AS A STANDARD ITEM SHALL BE PROADED BY THE PLUMBER OR 24" 24' ET" PLANS FOR DETAILS IT END CAP ELEERICIAN uxLEss SPECFIcnuY INDICATED Dx NIS PLAN.I x. I 4T 4T L--; El ITEM 211 09.01.2017 ® H - 36" 4Y 42" PAPER VOIDER , — e ITEM IS 4T 4T ti 4T ITEM 251 ITEM 522 CHECK ❑ II 6/6 WALL FLASHING FOS( OPRIINNTER SOLDER ❑ F -I ---- IP05 521 ITEM 36 ____ o L v- ___ MONITOR 8/5 PASS ❑ ?" a (BY OUTER) SHELF IL1 _________ ______ 'L _ — J ❑ talD I I I III I II`�II O m CK/ \ � _ _ ITEM 362 Q T ------- i- 4i 4T HOLDER -- ----- ---- zI ReD Q ��- 0 CONDIMENT RAIL , i 0 E_---M� 0 ---- ---- IL I6/6 TEM 501 CAPrieoo ` G 4 ANDS ING ZL 4T w ELEVATION - EXPO AREA 1/2°1 L0E 2 9 M � 00 w Tt.eoo L oe co J ' 71 FINISHED CEILING• BOTTOM SOFFIT- N W w Q ITEMh SEE ARCHIIER;R L SEE ARCHITECTURAL FO5 521 �� F'OS MONITOR PLANS FOR DETAILS PLANS FOR DETAILS � J ITEM 36 J S/S PASS ITEM 342 SHELF ITEM 34J ITEM 33 LL Q CUQ ITEM 50A CUTTING S/S ASSEMBL7 Ln O BOARD S/S END BOARD CABINET N ITEM 523 rCA'P�4 ITEM IS ITEM 21 ITEM 501 qq G) EWM1P BAR ICUT g HOLDER HOLDER CHECK PAPER M ILL L CZ, F BOARD DESIGNER: LINGLEDEBIGN INC. DRAWN: TRIMARK RAYGAL m '� CHECKED: TRIMARK RAYGAL TwIl"L-DER 21ER � �—— SCALE: A8 EHOUM i I i �n doe NUMBER: 58080 / SHEET TITLE T� _ L J ELEVATION KEYa }}qq ELEVATION PLAN I��FRFIGERATED IRIZRATED ITEM TE%4 PIIIA TABLE PIZZA TABLE CONTAINER (BY OWNER) SHEET NUMBER F554n- EQUPWENT KEY PLAN ;a Y o ELEVATION - ASSEMBLY AREA 1/2°1 LOE 3 UE SHEETS I I I I I I I I I I IITEM&6 I 6 ! i EXHAUST WOOD XNAUSi Tsi 30 G L-— J LK MrE WALL crrEHEdS I ITEM 25 SHELIANG HOLDER J I 3-SIDED ' r ITEM 522 �> ITEM 23 ITEM 25 ITEM 20.1 ITEM 52.1 L> J SPL A814 GAURD ITEM 521 J PDS. FRYER 5/6 SPLASH WALL PDS. PRINTER BATTERY GAURD BVffLF PRINTER GPoITDED L2E1 ITEM F COP COWTWOPEFAUCET DES. ITEM 312 1 BASKET -- -- — — ITEM . ITEM 50J �_ - S/B WALL S/S WALL I END c'4� DRAIN o I I I I ITEM 40 ITEM 31-3 _ -- _ ITEM 5 L 1 S/S NULL SZE I I I 1 GERATOR _ D SFkTN11 RR CAP RASHMG o o� o f FLL SZ I ITEM M'4cHITE,22 wowTOP I ITEM 2a ITEM 26 ITEM 28 FREEZER CHARIBROLER RER2IGERATED REFRIGERATED EfiIIP R STAND EQUIPMENT STAND ELEVATION - SOFT SERVE - _oE $ ELEVATION - FRYERS v2 T o 2 ELEVATION - COOIa�E v2 T-o 1 I 4 1/2' ITEM 52J F � ITEPAS y Ir� 1 � I 54 —TEM 57J I MONITOR \\] MONITORI \\ �/ // tt L PA1 L TOR MLNIIOR II ITEM 133 ITEM 13A ITEM 52J 6/5 WALL VEGETABLE ITEM 143 ITEM 14J ITEM 143 1fl DRIVE-THRU PDB SHELVMG FAUCET SHELWVMG ,7iaIFE ° WINDOW MONITOR .. SHELVES DICER .15" 6 /a" ITEM 60 ITEM 63 ITEM Ib 591/2• t 8/8 WALL M WALL ILE MACHIPE I1ESIMI ITEM 143 9 1/2• TEA Bfa'eLLER 54♦ELVES SHELVES 8HE SHELWVMG IRE AND D SF'ENSER r 20V4• TEM 13J ITEM 13 SERVICE FAUCET PREP TABLE 1 O O 0 0 3 COMPARMENT OPENING — ITEM 61 — — WITH SINK L�J SMC 1 T/a° S/S TABLE — — — 0 1 I I�� I �� I I SECTION TNRU 5�5 uTl Itt I SERVICE WINDOW ItLE E1 ITEM 132 D ITEM 132 1 HEAT 1MKAK 8/S CROSS BRACE LEVEL ITEM 523 LEVER WASTE 8/8 UNDER SHELF LEVER WASTE BUMP — BAR BEVII G. 'S�'W1c4 PREP TABLE ELEVATION - ICE MACHINE / DISHWASH AREA 1/2 _0" rj DRIVE THRU WINDOW DETAIL ELEVATION - DRIVE-THRU AREA 1/2 _0E 4 I I I 1 I I I ITEM I I S/S END CAPS I 1 1 ITEM 04 1 Sr.DECK ITEM ❑ ITFTTEEEM R 1 SHELDRY SvoRAGE SDRT HELVING FILTER I ITEM 6 I ITEMAND TOWEL C1EM I < < i DISPENSER ITEM RA J J MOP RACK r 9 Bee rC�Afe8I201JATOR � 1 I 1 TRIMARK RAYGAL 1 0T = II �iI I FAUCET ITEM 11 1 1 BAG-N-Box .I 1 I ITEM 06 RACKa :� I BULK DD2 I I AS SHOWN I5a+roR TANK 1 1 ITEM 063 I I 1 I SSCAP s a I ELEVATION PLAN I AND TRIM — 1 I I — 1 ITEM 3B I HAND SMK ELEVATION - HANDSINK 1/2 -0. 7 ELEVATION - JANITORS SINK / SODA RACK AREA 1/2i=o. s F551 PLUMBING KEYED NOTES MECHANICAL ROOF PLAN NOTES Ocu oA P1 NEW 4"VENT THRU ROOF. CONTRACTOR TO PROVIDE VENT PIPING (Ass g EXTENSIONS TO ENSURE VENT PIPING IN HIGHER THAN PARAPET. O GC PROVIDED AND INSTALLED ROOFTOP UNIT LOCATED AS SHOWN. REFER TO o e r ENSURE VENT THRU ROOF IS AT LEAST 10'-0"AWAY FROM ALL EXISTING ROOFTOP UNIT SCHEDULES ON SHEET M300 FOR I OUTSIDE AIR INTAKES. NFORMATION. CONTRACTOR SHALL MAINTAIN MANUFACTURER'S RECOMMENDED CLEARANCES V FIELD VERIFY LOCATION. AROUND ROOFTOP UNIT. ENSURE ROOFTOP UNIT OUTSIDE AIR INTAKE IS AT o LEAST 10'-0" MINIMUM FROM ANY EXHAUST FAN, GAS FLUE, OR VENT THRU b0 P2 NEW 3/4"HW UP TO ITEM #78 ON ROOF. COORDINATE LOCATION WITH ROOF. REFER TO SHEFT M200 FOR SUPPLY/RETURN AIR DUCT CONTINUATION. MECHANICAL CONTRACTOR AND OWNERS REPRESENTATIVE. VERIFY LOCATION IN FIELD. REPORT ANY DISCREPANCIES TO THE ARCHITECT. V 20 KITCHEN HOOD EXHAUST FAN WITH WIND BAND EXTENSIONS TO MATCH THE a HEIGHT OF THE PARAPET. RUN EXHAUST DUCT DOWN TO KITCHEN HOOD. SEE •�m SHEET M200 FOR CONTINUATION. LOCATE FAN OUTLET 10' MINIMUM FROM ANY AIR INTAKE. REFER TO HOOD DRAWINGS FOR INFORMATION. SLOPE THE EXHAUST °1 FAN 1/4" PER FOOT TOWARD THE DRAIN SPOUT ON THE EXHAUST FAN. 30 KITCHEN HOOD PSP MAKE-UP AIR UNIT (MUA-1). RUN SUPPLY DUCT DOWN TO KITCHEN HOOD PSP. SEE SHEET M200 FOR CONTINUATION. REFER TO HOOD DRAWINGS FOR INFORMATION. m I ROOFTOP COORDINATION NOTE: ®To"TOILET EXHAUST DUCT DISCHARGE UP THRU ROOF. TERMINATE 36" ABOVE m m a CONTRACTOR TO VERIFY LOCATION OF FINISHED ROOF WITH A 45' GOOSENECK. PROVIDE BIRD SCREEN AT z PARAPET BRACING IN FIELD AND ADJUST TERMINATION POINT. REFER TO SHEET M200 FOR CONTINUATION. LOCATE 10'-0" ED z u m m EQUIPMENT LOCATIONS AS REQUIRED. MINIMUM FROM ANY AIR INTAKE. FIELD VERIFY LOCATION. '0 m CONTACT ENGINEER IMMEDIATELY WITH ANY m J N in ISSUES. 50 REMOTE CONDENSER FOR WALK-IN COOLER, WALK-IN FREEZER AND ICE WALK-IN COOLS R 5 MACHINE SHALL BE MECHANICALLY FASTENED TO FIELD FABRICATED 3'-8" x 11' 3 w m CONDENSER x 9" PLATFORM WITH 9" ON THE SHORT SIDE OF THE ROOF. A SINGLE 4'x12' J B-17 SHEET OF SHEET METAL SHALL FORM THE WEATHER CAP OF THE PLATFORM. El a ALK-IN TAKE OFF FOR PIPING RUNS TO BE COORDINATED WITH GENERAL CONTRACTOR. ONDEN G.C. TO RUN WIRING FOR COOLER AND FREEZER AND FOR REMOTE ONDENSER E4 A2.1921 COMPRESSORS. MECHANICAL/ELECTRICAL SUBCONTRACTORS TO PERFORM FINAL CONNECTION FOR THESE UNITS. COORDINATE LOCATION WITH OWNER. FOR BIDDING PURPOSES, COOLER AND FREEZER REFRIGERANT PIPING COMES IN PRE-CHARGED LENGTHS OF 25' AND 50'. REFER TO ARCHITECTURAL o DRAWINGS FOR INFORMATION. ICE MACHINE 5 CONDENSER E4 A-13'15'17 ©DENOTES DUCT DROP DOWN THRU ROOF REFER TO SHEET M200 FOR 3.4 7 CONTINUATION. E1 B-19 SD 70 SMOKE DETECTOR IN THE RETURN AIR DUCT INSIDE THE ROOFTOP UNIT. ENSURE SMOKE DETECTION DEVICE IS TO BE INTERLOCKED WITH ROOFTOP UNIT SO AS TO SHUT UNIT DOWN UPON THE DETECTION OF SMOKE. WALK-IN FREEZE 5 �� CONDENSER ®ROUTE WATER HEATER 3" PVC FLUE VENT AND 3" PVC COMBUSTION AIR INTAKE E4 9 E3 OUT UP THRU ROOF. TERMINATE PER MANUFACTURER'S INSTRUCTION. WATER RTU 10 Pio HEATER IS FACTORY SUPPLIED WITH STANDARD TERMINATION 45 DEGREE ELBOW B-1 1 2 WITH PART #9006027015 RECESSED BIRDSCREEN. OBTAIN FROM G.C./P.C. IF A-3133 E2 FACTORY TERMINATION NOT USED, PROVIDE BIRDSCREEN EQUAL TO NORITZ ICE MACHI E 5 46.2 ES A_79 VT3-PVCS. REFER TO SHEET M200 FOR CONTINUATION. REFER TO PLUMBING CONDENS R EF 6 FIXTURE SCHEDULE ON SHEET P100 FOR INFORMATION. E4 2 1 O9 PROVIDE SINGLE PENETRATION FOR CONDENSING UNIT REFRIGERANT PIPING. NO PITCH POCKETS SHALL BE USED. B-27'29 a 10 4" VENT THRU ROOF. ENSURE VENT THRU ROOF IS 10'-C"AWAY FROM 16.1 3 Q 8 o OUTSIDE AIR INTAKES AND EXTENDED TO PARAPET. FIELD VERIFY LOCATION. n E6 30.1 2 EF 2 E2 E6 UA 1 3 30.3 Placement of roof 8 OUTDOOR AIR top units will be � E6 30.1 inspected by City 7 staff to ensure ELECTRICAL GENERAL NOTES E1 B-19 SD 6 1. ALL ELECTRICAL DEVICES LOCATED OUTDOORS SHALL BE W.P. OR WEATHER RESISTANT. ON AL with yS�piXALFN PUD and 2. ALL PENETRATIONS TO THE ROOF SHALL BE W.P. o��. %S^�T/EI�QC/y� obscured from 3. ALL ELECTRICAL ROOF PENETRATIONS SHALL BE 12"AWAY FROM ANY EQUIPMENT. Q V m E3 CONTRACTOR TO VERIFY EXACT LOCATION OF ALL ROOF TOP EQUIPMENT PRIOR TO START a 9316 � B-17 E7 view of parking lot of WORK. p and adjacent road 4 HORIZONTALTCONDUITS ALL BE INSTALLED INN THE PCEILING PERMITTED.SPACE BELOW ROOF. EXPOSED p�9 OF�pPyt� A-1 3 5 EF E2 RTU Q and properties. «p,cP 2 3 E8 1 1 N\ 5. SEE MECHANICAL DRAWINGS FOR ADDITIONAL EQUIPMENT INFORMATION. /5/1 E6 C_68 6. E.C.TO WIRE DISCONNECT& RECEPTACLE FOR RTU. E.C. TO EXTEND CIRCUITS AS REQUIRED. 3¢ 7. E.C. TO PROVIDE WALL MOUNTED REMOTE RESET FOR RTU SMOKE DETECTORS IN J MANAGER'S OFFICE, MOUNTED NEAR THE RTU THERMOSTATS (COORDINATE WITH MECHANICAL N CONTRACTOR). EACH REMOTE RESET SHALL BE LABELED INDICATING RTU-# SERVED. 8. E.C. TO PROVIDE ALL NECESSARY POWER& FINAL CONNECTIONS TO ROOF MOUNTED :.Q • • EQUIPMENT. COORDINATE ROOF PENETRATION REQUIREMENTS WITH LANDLORD. 9. E.C.TO FIELD VERIFY FINAL LOCATIONS OF ALL ROOF TOP EQUIPMENT.FIELD VERIFY THAT AT LEAST W (1) 120V RECEPTACLE IS LOCATED WITHIN 25'-0"(MAXIMUM),OF ALL EQUIPMENT THAT REQUIRES F W MAINTENANCE.PROVIDE ADDITIONAL ROOF TOP RECEPTACLES AS NEEDED.(NOTE:RECEPTACLES)NEED � Lu Of NOT TO BE LOCATED ON THE SAME LEVEL AS THE EQUIPMENT.) W O. H Y w o W Al— ELECTRICAL KEYED NOTES 0°aI o 14 cq { E1 E.C. PROVIDED SMOKE DUCT DETECTOR. E.C.TO WIRE SMOKE DUCT DETECTOR SO THAT =Z J ¢ — UPON ACTIVATION DETECTOR WILL SHUT DOWN RTU (COORDINATE WITH MECHANICAL W Z LO Z J r CONTRACTOR). E.C. TO CIRCUIT SMOKE DUCT DETECTOR AS INDICATED ON PLAN & MAKE f ALL FINAL CONNECTIONS. PROVIDE DUCT DETECTOR CIRCUIT BREAKER WITH HANDLE U m LOCK-ON CLIP. EC TO PROVIDE MONITOR MODULE AND RELAY MODULE TO MONITOR DUCT DETECTOR AND SHUT DOWN UNIT UPON SYSTEM ACTIVATION. E2 DISCONNECT PROVIDED WITH UNIT, E.C. TO PROVIDE ALL FIELD WIRING& CIRCUIT AS INDICATED. MAKE ALL FINAL CONNECTIONS PER MANUFACTURER'S SPECIFICATIONS. SEE Z PANEL SCHEDULE, SHEET E300 FOR ADDITIONAL INFORMATION. Q J E3 FACTORY INSTALLED W.P. GFCI CONVENIENCE RECEPTACLE. E.C. TO PROVIDE ALL FIELD WIRING&CIRCUIT AS INDICATED. PROVIDE ALL NECESSARY DEVICES& MAKE ALL FINAL = LL CONNECTIONS. E4 PROVIDE 30 AMP NON-FUSED DISCONNECT SWITCH AT CONDENSING UNIT. PROVIDE ALL o Z O FINAL CONNECTIONS PER MANUFACTURER'S SPECIFICATIONS AND CIRCUIT AS _ INDICATED. SEE PANEL SCHEDULE, SHEET E300 FOR ADDITIONAL INFORMATION. m E5 E.C. SHALL PROVIDE INTERCONNECTION COMMUNICATION WIRING FROM REMOTE ICE MACHINE CONDENSING UNIT(46.2)TO ICE MACHINE(46.1). PROVIDE ALL NECESSARY DEVICES& MAKE ALL FINAL CONNECTIONS. SEAL ALL ROOF PENETRATIONS. J al MEP ROOF PLAN E6 UNIT CIRCUITED VIA EXHAUST HOOD CONTROL PANEL. CONTRACTOR TO INTERLOCK MAU-1, EF-1, EF-2, & EF-3 STARTERS VIA HOOD FAN CONTROL SWITCH. SEE SHEET E210& SCALB. 114•-f-V HOOD MANUFACTURER SHOP DRAWINGS FOR MORE INFORMATION. IL W E7 CONTRACTOR TO PROVIDE AND MOUNT PHOTOCELL IN APPROXIMATE LOCATION SHOWN. J PROVIDE ALL REQUIRED BRACING FOR MOUNTING AND FACE PHOTOCELL NORTH. CIRCUIT o w AS INDICATED. E8 DISCONNECT PROVIDED WITH EXHAUST FAN UNIT. EC TO WIRE AS NECESSARY. m o N W COORDINATE IN FIELD WITH MC. 3 � U CA MEP10 H V,4C SPECIFICATIONS 14.2 EQUIPMENT INSTALLATION 14.7 AIR DEVICES _ FINAL HVAC SYSTEM TESTING AND BALANCING SHALL BE PERFORMED BY AN -- NOTE: MANUFACTURERS' NAMES ON WHICH THIS SPECIFICATION IS 12.3 FLEXIBLE DUCTWORK: ALL EQUIPMENT AND RELATED PIPING,DUCTWORK,CONTROL WIRING INSTALL ALL GRILLES AND DIFFUSERS TO BE FLUSH WITH THE AABC OR NEBB CERTIFIED INDEPENDENT THIRD PARTY AIR BALANCE CONTRACTORS & BASED INDICATE THE MINIMUM QUALITY OF PRODUCT REQUIRED. AND ACCESSORIES SHALL BE INSTALLED PARALLEL OR PERPENDICULAR PENETRATED SURFACE AND LEVEL OR STRAIGHT WITH WITH CONTRACTED DIRECTLY BY THE CONTRACTOR.A RE-TEST IS MANDATORY FOR A E ILA SUBSTITUTION MAY BE MADE TO THOSE SPECIFIED IF DEEMED SHALL HAVE AN IMPERVIOUS INNER CORE WITH WIRE REIN- TO BUILDING LINES AND,IF INSTALLED WITHIN THE BUILDING ENVELOPE SURROUNDING FEATURES. ALL CEILING MOUNTED AIR DEVICES FALSE START(I.E. NO POWER UPON AGENT'S ARRIVAL, EQUIPMENT NOT WIRED, EQUIVALENT BY THE OWNER'S REPRESENTATIVE THRU A SUBMITTAL FORCEMENT. THE INNER DUCT SHALL BE COVERED WITH SHALL BE INSTALLED AS HIGH AS POSSIBLE TO ALLOW THE MAXIMUM SHALL BE LOCATED IN THE CEILING TILE INDICATED ON THE ETC)AND SHALL BE A COST INCURRED BY THE G.C. IN THE EVENT A u V PROCESS. ALL WORK AND PRODUCTS SHALL MEET THE REQUIREMENTS 1.5" THICK FIBERGLASS DUCT INSULATION WITH A POLY- AMOUNT OF HEADROOM. EQUIPMENT THAT REQUIRES ROUTINE DRAWINGS. SUPPORT CEILING MOUNTED GRILLES AND DIFFUSERS SYSTEM/STORE RECEIVES AN UNACCEPTABLE GRADE AS A RESULT OF THE HVAC a OF THE OWNER AND GOVERNING CODES. ETHYLENE VAPOR-PROOF JACKET. FLEXIBLE DUCT SHALL BE MAINTEN- ANCE SUCH AS FILTER REPLACEMENT SHALL BE INSTALLED AT THE PROPER HEIGHT TO HOLD IT SNUG AGAINST THE CEILING. SYSTEM PERFORMANCE OR OPERATIONAL DEFICIENCIES,OWNER WILL REQUEST A bo 0 UL-181 LISTED, CLASS 1, AND SHALL MEET ALL APPLICABLE AND ARRANGED TO BE ACCESSIBLE. PROVIDE ACCESS PANEL(S)AS RE-TEST AND THE COST FOR SAME SHALL BE ALSO INCURRED BY THE GENERAL c 1. ALL WORK SHALL BE PERFORMED IN CONFORMANCE WITH ALL CODES AND THE REQUIREMENTS OF THE LANDLORD. 14.8 DUCT SEALANT w REQUIRED AND/OR AS RECOMMENDED BY THE EQUIPMENT CONTRACTOR. DEVIATION BETWEEN DESIGN AND MEASURED QUANTITIES SHALL NOT V y APPLICABLE CODES AND THE OWNER'S MINIMUM REQUIREMENTS MANUFACTURER. ALL EQUIPMENT SHALL BE INSTALLED WITH THE BE GREATER THAN 5%. PROVIDE REPORT TO TENANT/MECHANICAL AS STATED HEREIN OR OTHERWISE INDICATED BY THE OWNER. FITTINGS TO CONNECT THE FLEX DUCT TO THE TRUNK DUCT REQUIRED CLEARANCES AS RECOMMENDED BY THE EQUIPMENT SEAL SUPPLY AND RETURN DUCT TRAVERSE JOINTS FOR ENGINEER/M.C. - SEE SCOPE OF WORK ON SHEET M300. SHALL BE OF THE 45' LEAD-IN TYPE PER THE LATEST OF •�w = =oE LL MANUFACTURER OR AS REQUIRED BY GOVERNING CODES,WHICHEVER PRESSURE CLASS C, LESS THAN 2"W.G. PRESSURE. SEAL 2. SEE ARCHITECTURAL GENERAL AND SPECIAL CONDITIONS. ALL SMACNA STANDARDS AND SHALL HAVE AN OPPOSED BLADE IS GREATER. TOILET EXHAUST DUCT JOINTS FOR -2"W.G. CONDITION REQUIREMENTS SHALL APPLY UNLESS OTHERWISE NOTED. VOLUME DAMPER, SQUARE-TO-ROUND TRANSITION AND SHALL .= " HAVE THE SAME FREE AREA AS THE SPECIFIED FLEX DUCT. SPRINKLER SPECIFICATIONS 14.3 DUCTWORK �' LLa 3. ALL WORK SHALL BE PERFORMED AS INDICATED ON DRAWINGS 14.9 RANGE HOOD EXHAUST DUCTS UNLESS FIELD CONDITIONS REQUIRE MINOR CHANGES BE MADE. FLEX DUCT SHALL BE THE PRODUCT OF AN ESTABLISHED LOW PRESSURE DUCTWORK AND FITTINGS SHALL BE MADE 1. NEW SPRINKLER GRID SYSTEM AND FIRE PROTECTION SERVICE SHALL BE MINOR CHANGES SHALL BE MADE WITH NO ADDITIONAL COST. MANUFACTURER OF SUCH PRODUCTS AND EQUIVALENT TO TIGHT FOR MINIMUM AIR LEAKAGE. DUCT TAPE SHALL NOT FABRICATE RANGE HOOD EXHAUST DUCTS AND GREASE DUCTS WITH INSTALLED BY THE LANDLORD, HEREINAFTER REFERRED TO AS"CONTRACTOR". CERTAINTEED MODEL G-25, WIREMOLD WGC, OR PPG 0.0598-INCH-THICK, CARBON-STEEL SHEET FOR CONCEALED DUCTS 4. ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR GOSSFLEX. BE USED TO SEAL JOINTS, TO MAKE TRANSITIONS OR FOR AND 0.0500-INCH-THICK STAINLESS STEEL FOR EXPOSED DUCTS. SPRINKLER HEAD LOCATIONS SHALL BE COORDINATED WITH THE NEW ELEMENTS N ANY OTHER REASON ON THE OUTSIDE OF WRAPPED OF THE REFLECTED CEILING PLAN. _ AFTER FINAL ACCEPTANCE OF THE WORK BY THE OWNER. INSULATION. WELD AND FLANGE SEAMS AND JOINTS. COMPLY WITH NFPA 96. W m ^ 12.4 DUCT INSULATION 5. CONTRACTOR SHALL PREPARE AND SUBMIT AS-BUILT DRAWINGS THE WORK CONSISTS OF FURNISHING ALL LABOR,MATERIALS, TOOLS, ALL SEAMS,JOINTS,PENETRATIONS,AND DUCT-TO-HOOD COLLAR TO THE OWNER IF REQUESTED. AS-BUILT DRAWINGS SHALL ALL SUPPLY, MAKE-UP AND RETURN AIR DUCTWORK EXCEPT INSTALL DUCTWORK AS HIGH AS POSSIBLE. EQUIPMENT,SERVICES AND SUPERVISION REQUIRED TO INSTALL,TEST AND ?^ `�Q`m CONNECTIONS SHALL HAVE ALIQUID-TIGHT CONTINUOUS EXTERNAL WELD. m m o w ( PLACE IN SERVICE A COMPLETE FIRE PROTECTION SYSTEM IN STRICT INDICATE THE ACTUAL MANUFACTURER OF THE EQUIPMENT THAT FLEXIBLE DUCTS) SHALL BE INSULATED (R-6) EXTERNALLY UNLESS PROVIDE TURNING VANES AT ALL CHANGES IN DIRECTION. ACCORDANCE WITH THIS SPECIFICATION AND APPLICABLE DRAWINGS. m J Nin WAS INSTALLED, THE EXACT LOCATION OF THE EQUIPMENT AND SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. EXTERNAL DUCT 14.10 RANGE HOOD EXHAUST AND GREASE DUCT INSTALLATION z ..m PERTINENT CAPACITIES FOR HEATING, COOLING, ETC. INSULATION (DUCT WRAP) SHALL BE 2"THICK FIBERGLASS DUCT PROVIDE VANED TEES AT BRANCH CONNECTIONS SERVING NEW SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF THE NATIONAL FIRE 3 w i.. WRAP WITH VINYL FSK FACING. DUCT WRAP SHALL HAVE A K-FACTOR SERVING MORE THAN ONE DIFFUSER. INSTALL DUCTS TO ALLOW FOR THERMAL EXPANSION THROUGH 2O00 DEG F PROTECTION ASSOCIATION (NFPA),INDUSTRIAL RISK INSURANCE(IRI), z 6. EQUIPMENT, FIXTURES, AND ACCESSORIES SHALL NOT BE SUP- OF .28 AT 75°F MEAN AND DENSITY OF 1 LB./C.F. TEMPERATURE RANGE. LANDLORD'S INSURANCE UNDERWRITER(IF APPLICABLE)AND THE LOCAL z a PORTED FROM CEILING, SOFFIT, NEUTRAL PIERS, PIPING, DUCT- PROVIDE VOLUME CONTROL DAMPERS AND BALANCING DE- AUTHORITIES HAVING JURISDICTION. TESTING OF SPRINKLER SYSTEM SHALL BE WORK, METAL ROOF DECK, LATERAL BRACING, BRIDGING OR ALL DUCT INSULATION SHALL BE UL LABELED FOR FIRE AND SMOKE VICES AS REQUIRED TO DISTRIBUTE THE AIR AND AS INDI- INSTALL DUCTS WITHOUT DIPS OR TRAPS THAT MAY COLLECT RESIDUES. ACCORDING TO LOCAL CODES AND MUST BE WITNESSED BY OWNER'S CONDUIT. ITEMS SHALL ONLY BE SUPPORTED FROM STRUCTURE RATINGS. GATED ON THE DRAWINGS. INSTALL ACCESS OPENINGS AT EACH CHANGE IN DIRECTION AND AT 20-FOOT REPRESENTATIVE AND/OR REPRESENTATIVE OF LOCAL FIRE MARSHAL'S OFFICE. WHICH HAS BEEN APPROVED BY THE ARCHITECT FOR SUPPORT. INTERVALS; LOCATE ON SIDES OF DUCT A MINIMUM OF 1-1/2 INCHES FROM 7. ALL ROOF WORK PENETRATIONS AND REPAIRS SHALL BE TOTALLY DUCT INSULATION SHALL BE EQUAL TO PRODUCTS MANUFACTURED BY NOTE: DUCT DIMENSIONS INDICATED ON THE DRAWINGS ARE BOTTOM; AND FIT WITH GREASE-TIGHT COVERS OF SAME MATERIAL AS DUCT. PERFORMED BY ONLY THOSE ROOFING CONTRACTORS APPROVED JOHNS MANVILLE AND SHALL BE INSTALLED IN STRICT ACCORDANCE INSIDE CLEAR, OR "FREE AREA" DIMENSIONS. CONTRACTOR A SIGN SHALL BE PLACED ON ALL ACCESS PANELS STATING THE FOLLOWING: 2. CONTRACTOR SHALL VISIT THE SITE AND VERIFY EXISTING CONDITIONS, PRIOR BY THE OWNER/LANDLORD. WITH THE MANUFACTURER'S RECOMMENDATIONS. SHALL MAKE ALLOWANCE FOR INTERNAL DUCT LINER (WHERE "ACCESS PANEL-DO NOT OBSTRUCT" TO SUBMITTING A BID. SPECIFIED) WHEN ORDERING PRE-FABRICATED DUCTWORK OR 8. INSTALLATION OF ROOF MOUNTED EQUIPMENT SHALL BE OOR- WHEN FABRICATING DUCTS IN THE FIELD. DO NOT PENETRATE FIRE-RATED ASSEMBLIES. 3, SYSTEM SHALL BE HYDRAULICALLY VERIFIED BASED ON THE EXISTING DINATED WITH THE GENERAL CONTRACTOR AND OTHER TRADES. 12.5 DUCT SEALANT ADES. PITCH DUCTS TOWARD KITCHEN HOOD TO ALLOW DRAINAGE A MINIMUM OF COVERAGE, SUBJECT TO THE APPROVAL DESIGN BY OWNER'S INSURANCE DUCT WRAP SHALL BE INSTALLED IN A NEAT AND COMPETENT UNDERWRITER AND LOCAL CODES. COVERAGE SHALL BE BASED ON NET 9. DEFICIENCIES AND NON-CONFORMING ITEMS SHALL BE CORRECTED 1. ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS,AND MANNER WITH ALL EDGES NEATLY COVERED WITH AN APPROVED 1/4"PER LINEAL FOOT. LEASED SPACE. BY THE CONTRACTOR. FAILURE TO CORRECT SUCH ITEMS SHALL CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING METALLIC DUCT TAPE TO VAPOR-PROOF THE ENTIRE DUCT. LAPS PERMIT THE LANDLORD TO CORRECT SAME AT A COST TO THE WELDMENTS; MECHANICAL FASTENERS WITH SEALS, GASKETS, OR MASTICS; AND JOINTS SHALL BE SECURED WITH INSULATION STAPLES AND THE GREASE DUCT SHALL BE TESTED BY AN INDEPENDENT THIRD PARTY FOR MINIMUM DENSITY: ORDINARY HAZARD CONTRACTOR. MESH AND MASTIC SEALING SYSTEMS; OR TAPES. TAPES AND MASTICS THEN COVERED WITH APPROVED TAPE. THE GREASE DUCT SYSTEM WHICH WILL BE REVIEWED,APPROVED AND SIGNED MUST BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A OR UL OFF BY THE MECHANICAL ENGINEER OF RECORD ON ALL PROJECTS.THE 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL 181B.ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND GENERAL CONTRACTOR SHALL PROVIDE FOR THE GREASE DUCT PRESSURE MINIMUM OPERATING PRESSURE FOR ANY SPRINKLER SHALL NOT BE LESS PERMITS AND PAYING FOR SAME. HE SHALL INCLUDE IN HIS BID CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING AT STATIC 14.4 FLEXIBLE DUCTWORK TEST FOR THE PURPOSES OF WELD INTEGRITY CERTIFICATION. THAN REQUIRED BY NFPA 13; MAXIMUM DISCHARGE PRESSURE USED AT PRESSURES LESS THAN OR EQUAL TO 2"W.G. SHALL BE SECURELY STARTING POINT SHALL NOT EXCEED REQUIREMENTS OF NFPA 13. CHARGES FOR ALL FEES ASSOCIATED WITH THE CONSTRUCTION DUCTWORK SHALL BE LIMITED IN LENGTH TO THAT NECESSARY TO OF THE SPACE INCLUDING BUT NOT LIMITED TO LOCAL, COUNTY, FASTENED AND SEALED WITH WELDS GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS-EMBEDDED FABRIC SYSTEMS OR TAPES INSTALLED IN MAKE CONNECTIONS BETWEEN TRUNK OR BRANCH DUCTS AND AIR 4. CONTRACTOR SHALL PREPARE DRAWINGS TO LOCATE HEADS SHOWN ON PLAN OR STATE SERVICE CHARGES AND PERMIT FEES, AND UTILITY HOOD PERFORMANCE TEST AND/OR EQUIPMENT CHARGES. ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. DEVICES.FLEX DUCT LENGTH SHALL NOT EXCEED 8'-0 A PERFORMANCE TEST SHALL BE CONDUCTED UPON COMPLETION OF INSTALLATION AND SHALL RESPONSIBLE FOR THE COST OF ALL PERMITS AND FEES,1 T AND BEFORE FINAL APPROVAL OF THE EXHAUST SYSTEM SERVING THE EXHAUST WEEK PRIOR TO START OF CONSTRUCTION. 11. THE SCOPE OF WORK OF THIS CONTRACT INCLUDES, BUT SHALL 2. MECHANICAL FASTENERS AND SEALS, MASTICS, OR GASKETS MUST BE ALL FLEX DUCT SHALL BE FULLY STRETCHED OUT TO REDUCE AIR HOOD.THE TEST SHALL VERIFY THE RATE OF EXHAUST AND MAKEUP AIRFLOW PER NOT BE LIMITED TO: USED WHEN CONNECTING DUCTS TO FANS AND OTHER AIR DISTRIBUTION RESISTANCE. CODE. 5. SPRINKLER MAINS AND BRANCHES EQUIPMENT. PROVIDE AND INSTALL ALL EQUIPMENT, APPLIANCES, CON- CONNECTIONS TO FITTINGS OR AIR DEVICES SHALL BE MADE WITH TWO A FIELD TEST SHALL BE PERFORMED FOR THE EXHAUST SYSTEM FOLLOWING THE PIPING MATERIAL: BLACK STEEL, SCHEDULE 40 OR LIGHTWEIGHT SPRINKLER TROL DEVICES, ACCESSORIES, MATERIAL AND LABOR. (2)STAINLESS STEEL BANDS. THE INNER LINER SHALL BE CLAMPED INSTALLATION OF THE COOKING EQUIPMENT UNDER THE HOOD AT OPERATING PIPE,SCHEDULE 10, ASTM A 135(IF ALLOWED BY LOCAL AUTHORITIES) 12.6 PIPING AND FITTINGS TIGHT WITH THE FIRST BAND, THEN THE INSULATION AND TEMPERATURES.A SMOKE/STEAM TEST SHALL BE PERFORMED TO VERIFY HOOD PROVIDE AND INSTALL ALL DUCTWORK, INSULATION, AIR VAPOR-PROOF JACKET PULLED TO BE TIGHT AGAINST THE DUCT CAPTURE AND CONTAINMENT. DEVICES, DUCT ACCESSORIES, MATERIAL AND LABOR. CONDENSATE DRAIN PIPING SHALL BE TYPE L COPPER WITH FITTING OR AIR DEVICE AND SECURED WITH THE SECOND BAND. FITTINGS: THREADED,CLASS 175. MECHANICAL COUPLINGS AND TEES OF A SOLDERED JOINTS AND WROUGHT COPPER FITTINGS. INSTALLATION SHALL BE AS RECOMMENDED BY THE DUCT GREASE DUCT TEST ROLLED GROOVED TYPE WILL BE ACCEPTED (IN LIEU OF THREADED) IF BOTH PROVIDE AND INSTALL ALL PIPING, FITTINGS, VALVES, IN- MANUFACTURER AND SMACNA. PRIOR TO USE OF THE EXHAUST EQUIPMENT AND APPLICATION OF DUCT WRAP A U.L. AND FIRE MARSHAL LISTED AND APPROVED. SULATION, ACCESSORIES, MATERIAL AND LABOR. 12.7 CONTROLS LEAKAGE TEST SHALL BE PERFORMED ON THE GREASE DUCT SYSTEM.A PRESSURE SUPPORT THE FLEXIBLE DUCT WITH ADEQUATE HANGERS TO TEST SHALL BE PERFORMED ON THE ENTIRE DUCT SYSTEM INCLUDING HOOD-TO 6. INSTALLATION: PROVIDE AND INSTALL EXHAUST SYSTEM(S) INDICATED. PROVIDE CONTROLS AND WIRING TO PERFORM THE SEQUENCES RELIEVE STRAIN ON ANY FITTING.UNNECESSARY BENDS, SAGS, DUCT CONNECTION FOR DETERMINING THAT ALL WELDED AND BRAZED JOINTS ARE TWISTS,ETC.,WILL NOT BE ALLOWED. LIQUID TIGHT. ALL SPRINKLER PIPING SHALL BE CONCEALED UNLESS OTHERWISE INDICATED, PROVIDE AND INSTALL ALL ROOF WORK, INCLUDING EQUIP- DESCRIBED ON THE PLANS. WIRING SHALL BE MINIMUM 18 AWG, ALL PIPING SHALL BE LOCATED TO AVOID INTERFERENCE WITH ALL OTHER MENT SUPPORTS, ROOF PENETRATIONS, PATCHING AND NON-SHIELDED, BUNDLED CABLES. INSTALL ALL WIRING IN EMT 14.5 ROUND AND FLAT OVAL DUCTWORK ELEMENTS ABOVE CEILINGS, ETC. WATERPROOFING OF ROOF. CONDUITS AND JUNCTION BOXES CONFORMING TO 2011 NEC. 15. INSTALL ROOF MOUNTED EQUIPMENT SUPPORT RAILS OR ROOF CURB AS ALL ROUND AND FLAT OVAL SUPPLY, RETURN AND EXHAUST DUCTWORK REQUIRED FOR THE JOB CONDITIONS AND AS RECOMMENDED BY THE SUPPORT ALL HORIZONTAL PIPING AT NOT GREATER THAN 10 FOOT PROVIDE ALL EQUIPMENT SUPPORTS AND HANGERS INCLUD- 13. EQUIPMENT SHALL BE UNDAB,UNITED MCGILL OR SEMCO DUCT SYSTEMS CONSISTING MANUFACTURER FOR THE INSTALLATION OF ROOF MOUNTED EQUIPMENT. THE INTERVALS, EXCEPT PIPES OF SIZE 1-1/2"AND LARGER WHICH SHALL BE ING ANY AUXILIARY STEEL REQUIRED. ANY STRUCTURAL MOD- OF FITTINGS THAT ARE FACTORY FITTED WITH A SEALING GASKET AND EXACT LOCATION OF ALL ROOF MOUNTED EQUIPMENT IS SUBJECT TO SITE SUPPORTED AT NOT GREATER THAN 15 FOOT INTERVALS, WITH APPROVED FICATION TO THE BUILDING STRUCTURE SHALL BE MADE ONLY HVAC EQUIPMENT SHALL BE AS SCHEDULED ON THE DRAWINGS SPIRAL DUCT WHICH, WHEN INSTALLED ACCORDING TO THE CONDITIONS AND THE APPROVAL OF THE GENERAL CONTRACTOR. COORDINATE SWIVEL SPLIT RING HANGERS WITH ROD SUPPORTS AND SWAY BRACES AT _ �j\ONIAL Fjy WITH THE WRITTEN APPROVAL OF THE LANDLORD. AND/OR SPECIFIED HEREIN. EQUIVALENT EQUIPMENT AND/OR MANUFACTURER'S INSTRUCTIONS, WILL SEAL THE DUCT JOINTS WITHOUT THE ENTIRE INSTALLATION WITH THE GENERAL CONTRACTOR AND OTHER EVERY THIRD HANGER. COMPONENTS THEREOF MAY BE SUBSTITUTED FOR SPECIFIED THE USE OF DUCT SEALER. TRADES. PROVIDE LOW VOLTAGE CONTROLS WIRING BETWEEN THERMOSTATS, EQUIPMENT ONLY AS APPROVED BY THE OWNER AND/OR THE ALL SPRINKLER PIPING SHALL BE INSTALLED SO THAT IT CAN BE [r SENSORS AND ROOF MOUNTED EQUIPMENT. PROJECT ENGINEER. MATERIAL: ALL DUCT AND FITTINGS SHALL BE G-90 OR G-60 CONTRACTOR SHALL PROVIDE A TEMPORARY PLYWOOD WORK PLATFORM THAT THOROUGHLY DRAINED,AND WHERE PRACTICAL,ARRANGED TO DRAIN TO THE a 9316 GALVANIZED STEEL IN ACCORDANCE WITH ASTM A-643 AND A-924. COMPLETELY SURROUNDS THE AREA WHERE NEW ROOF MOUNTED EQUIPMENT MAIN VALVE. CLEAN, TEST AND PUT INTO SERVICE ALL SYSTEMS SPECIFIED. 14. EXECUTION AND/OR DUCTS ARE TO BE INSTALLED. THE ENTIRE WORK AREA SHALL N� . 14.1 GENERAL CONSTRUCTION: ALL DUCT AND FITTINGS SHALL BE CONSTRUCTED PER REMAIN ON THE ROOF DURING THE ENTIRE PERIOD OF INSTALLATION AND 7. SPRINKLER HEADS 099�or - PROVIDE \OQ'�ki PROE A BALANCE REPORT PREPARED BY AN INDEPENDENT AABC SMACNA'S DUCT CONSTRUCTION STANDARDS+10 IN. W.G. FITTINGS: SHALL BE REMOVED FROM THE ROOF AND THE SITE BY THIS CONTRACTOR T9 O OR NEBB CERTIFIED AIR BALANCE CONTRACTOR. UPON COMPLETION OF THE INSTALLATION. ALL SPRINKLER HEADS SHALL BE 1/2"ORIFICE, RATED AT 165 DEGREES FLL R• ACCESSIBILITY - ALL EQUIPMENT SHALL BE INSTALLED IN a. ALL FITTING ENDS SHALL COME FACTORY EQUIPPED WITH A SEALING WITH A'K-FACTOR'OF 5.65 UNLESS OTHERWISE NOTED. /`5/1 WARRANTY ALL WORK AND MATERIALS HEREIN SPECIFIED FOR SUCH A MANNER THAT ALL COMPONENTS REQUIRING ACC- GASKET. GASKET SHALL BE CLASSIFIED BY UNDERWRITER'S ALL ROOF PENETRATIONS FOR POWER AND CONTROL WIRING CONDUITS AND A PERIOD OF NOT LESS THAN ONE YEAR. ESS ARE LOCATED AND INSTALLED THAT THEY MAY BE SER- LABORATORIES TO CONFORM TO ASTM E84-91A AND NFPA 90A GAS,CONDENSATE,OR REFRIGERANT PIPING SHALL BE MADE WITH ALL SPRINKLER HEADS IN TOILET AREA SHALL BE SEMI-RECESSED TYPE, 165 VICED, RESET, REPLACED, OR RECALIBRATED, ETC., BY SER- FLAMESPREAD AND SMOKE DEVELOPED RATINGS OF 25/50. WATERPROOF PIPE SLEEVES. DEG RATED, WITH FINISHES OF CHROME PLATED HEAD AND WHITE PAINTED 12. MATERIALS VICE PEOPLE WITH NORMAL SERVICE TOOLS AND EQUIPMENT. ESCUTCHEON COLORS, G1 AS MANUFACTURED BY RELIABLE AUTOMATIC b. ALL FITTINGS SHALL BE CONTINUOUSLY STITCH WELDED OR SHALL BE 16. THIS CONTRACTOR SHALL ENGAGE THE SERVICES OF AN AABC OR NEED SPRINKLER CO., INC OR APPROVED EQUAL. J 12.1 ALL MATERIALS SHALL BE NEW AND OF RECOGNIZED COM- WORK BY OTHER TRADES - FOR THE WORK REQUIRED BY CERTIFIED INDEPENDENT THIRD PARTY AIR BALANCE CONTRACTOR. MERCIAL QUALITY. USED MATERIALS WILL NOT BE PERMITTED. OTHER TRADES FOR CHANGES MADE BY THIS CONTRACTOR STANDING SEAM GORELOCK CONSTRUCTION AND INTERNALLY SEALED. CONTRACTED DIRECTLY BY THE CONTRACTOR. A T'STESTIS MANDATORY o IN TYPE OR SIZE OF EQUIPMENT PURCHASED, ANY CUTTING, THE RADIUS OF ALL 90'AND 45°ELBOWS SHALL BE 1.5 TIMES THE SPRINKLER HEADS IN TECTUM CEILING SHALL BE SEMI-RECESSED TYPE, 165 ELBOW DIAMETER. THE RADIUS OF ALL 15', 30'AND 60'ELBOWS FOR A FALSE START(LE. NO POWER UPON AGENT'S ARRIVAL, EQUIPMENT DEG RATED,WITH FINISHES OF WHITE POLYESTER COATED HEAD AND CHROME ch 12.2 DUCTWORK: PATCHING, FURRING, PAINTING, ELECTRICAL OR PLUMBING SHALL BE 1.0 TIMES THE ELBOW DIAMETER. ALL FITTINGS THAT ARE NOT WIRED, ETC.) AND SHALL BE A COST INCURRED BY THE G.C. IN THE PLATED ESCUTCHEON COLORS. L1J ALL DUCTWORK SHALL BE DESIGNED IN ACCORDANCE WITH THE WORK SHALL BE DONE BY THE AFFECTED TRADE AT THIS OF EITHER SPOT WELDED OR BUTTON PUNCHED WELDED OR BUTTON EVENT A SYSTEM/STORE RECIEVES AN UNACCEPTABLE GRADE AS A w SOCIETY OF HEATING REFRIGERATION AND AIR CONDITIONING ENGINEERS PROCEDURES DESCRIBED IN THE LATEST EDITION OF THE AM EGINE CONTRACTOR'S EXPENSE.ERS WORK NOT INCLUDED-POWER WIRING, INCLUDING FINAL CONNECTIONS, PUNCHED CONSTRUCTION SHALL BE INTERNALLY SEALED. RESULT OF THE HVAC SYSTEM PERFORMANCE OR OPERATIONAL SPRINKLER HEADS IN PERIMETER AREAS OF THE DINING ROOM AT DEFICIENCIES,OWNER WILL REQUEST A RE-TEST AND THE COST FOR STOREFRONT SOFFITS WITH FINISHED DRYWALL CEILINGS SHALL BE W GUIDE (ASHRAE), FABRICATED AND INSTALLED IN ACCORDANCE WITH THE SHALL BE BY THE ELECTRICAL CONTRACTOR. THE MECHANICAL C. WHEN CONTRACT DOCUMENTS REQUIRE DIVIDED FLOW FITTINGS ONLY SAME SHALL BE ALSO INCURRED BY THE GENERAL CONTRACTOR. SEMI-RECESSED TYPE, 165 DEG RATED, WITH FINISHES OF CHROME PLATED METHODS RECOMMENDED IN THE SHEET METAL AND AIR CONDITIONING CONTRACTOR SHALL FURNISH THE STARTING EQUIPMENT TO THE FULL BODY FITTINGS WILL BE ACCEPTED. CONTRACTOR SHALL PROVIDE THE OWNER AND THE ARCHITECT A COPY HEAD AND WHITE PAINTED ESCUTCHEON COLORS. Cn 22 CONTRACTORS NATIONAL ASSOCIATION (SMACNA) LOW VELOCITY DUCT ELECTRICAL CONTRACTOR FOR INSTALLATION. CONTROL WIRING, INCLUDING OF THE CERTIFIED AIR BALANCE REPORT SHOWING DESIGN AND MEASURED Lu _ MANUAL, LATEST EDITION, AS WELL AS INTERNATIONAL BUILDING CODE. 115V FROM POWER SOURCE,CONDUIT AND SWITCHES SHALL BE d. ALL BRANCH CONNECTIONS SHALL BE MADE AS A SEPARATE AIR QUANTITIES, STATIC PRESSURES, FAN MOTOR RPM AND MOTOR SPRINKLER HEAD IN AREA OF FINISHED DRYWALL CEILING THAT IS IN FRONT 05 DUCT WORK SHALL BE SHEETMETAL EXTERNALLY WRAPPED WITH 2" FURNISHED BY THE MECHANICAL CONTRACTOR. CONTROL DEVICES, FITTING. FIELD INSTALLATION OF TAPS INTO SPIRAL DUCT SHALL CURRENT. DEVIATION BETWEEN DESIGN AND MEASURED QUANTITIES SHALL OF THE MENU BOARD SHALL BE CONCEALED TYPE,EXTENDED COVERAGE, 165 ~Y L1J O W THICK FIBERGLASS (1 LB. DENSITY) INSULATION HAVING AN R VALUE OF THERMOSTATS,INTERLOCKS, ETC. SHALL BE FURNISHED BY THE NOT BE ALLOWED. NOT BE GREATER THAN 5%. - SEE SCOPE OF WORK ON SHEET M300. DEG RATED,K-FACTOR OF 11.2 AND WITH WHITE COVER PLATE FINISH. m Q O u CD 6; FOIL FACED,INSULATION HAVING AN R VALUE OF 6. MECHANICAL CONTRACTOR. WIRING DIAGRAMS AND INSTALLATION INSTRUCTIONS SHALL BE FURNISHED TO THE OWNER UPON PROJECT ALL VOLUME DAMPERS SHALL BE FITTING SIZED TO SLIP INTO SPIRAL 17. ALL MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE SPRINKLER HEADS IN AREA OF FINISHED DRYWALL CEILING IN THE EXPO AREA =Z Q COMPLETION. DUCT. RUSKIN MD15 SERIES, OR EQUAL BY AMB, DAMPER SHALL HAVE GUARANTEED FOR A MINIMUM PERIOD OF ONE(1)YEAR FROM THE AND AREAS OF THE DINING ROOM AT COMMUNITY TABLE SHALL BE J NEW 2"THICK EXTERNALLY (1"LB. DENSITY) WITH VALUE OF R-6 THE FOLLOWING FEATURES: DATE OF ACCEPTANCE BY THE OWNER. DEFECTS WHICH APPEAR DURING SEMI-RECESSED TYPE, 165 DEG RATED, WITH FINISHES OF CHROME PLATED w Z INSULATED "LOW PRESSURE" SUPPLY AIR DUCT INSTALLED BY HVAC THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE. HEAD AND CHROME PLATED ESCUTCHEON COLORS. rn CONTRACTOR. PROVIDE TRANSITIONS AS REQUIRED, DUCT DIMENSIONS ARE a. LOCKING QUADRANT WITH BLADE. FOR THE SAME PERIOD, THIS CONTRACTOR SHALL BE RESPON- SIBLE ~U m CLEAR INTERNAL AIR PATH DIMENSIONS. b. POSITION INDICATOR. FOR ANY DAMAGE CAUSED TO THE PREMISES BY DEFECTS IN HIS SPRINKLER HEADS IN AREAS WITH LAY-IN CEILINGS SHALL BE STANDARD c. 2"SHEET METAL INSULATION STAND-OFF INTEGRAL SHAFT/BLADE WORKMANSHIP OR WORK AND/OR EQUIPMENT INSTALLED BY OTHERS PENDENT TYPE, 165 DEG RATED, WITH CEILING SHIELD. FINISHES SHALL BE FLEXIBLE AIR DUCT FOR CONNECTIONS BETWEEN S.M. DUCT AND ASSEMBLY. UNDER HIS CONTRACT. BRONZE HEAD AND WHITE PAINTED CEILING SHIELD. HEADS SHALL BE MODEL DIFFUSER SHALL BE AIR DUCT LISTED BY UNDERWRITERS LABORATORIES d. SHAFT MOUNTED, LOAD BEARING BUSHINGS. G AS MANUFACTURED BY RELIABLE AUTOMATIC SPRINKLER CO., INC OR UNDER UL STANDARD 181 AS A CLASS 1 FLEXIBLE AIR DUCT AND e. GASKETED SHAFT PENETRATIONS TO MINIMIZE LEAKAGE. 18. TESTING AND ADJUSTING APPROVED EQUAL. ALL SPRINKLER HEADS TO BE CENTERED IN TILE. COMPLYING WITH NFPA STANDARDS 90A AND 90B. DUCT SHALL BE U) FACTORY MADE AND COMPOSED OF A CPE LINER DUCT PERMANENTLY PERFORMANCE: SELF SEALING DUCT SYSTEM PERFORMANCE SHALL MEET SPRINKLER HEADS IN AREA OF NO CEILING SHALL BE MODEL G UPRIGHT, BOUNDED TO A COATED SPRING STEEL WIRE HELIX AND SUPPORTING A .CONTRACTOR SHALL DEMONSTRATE OPERATION OF THE COMPLETE - Z SMACNA'S LEAKAGE CLASS 3 REQUIREMENTS AT-10 IN W.G. TO+10 IN SYSTEM TO FULL SATISFACTION OF TENANT BRONZE AS MANUFACTURED BY RELIABLE AUTOMATIC SPRINKLER CO.,INC. OR FIBER GLASS INSULATING BLANKET. R.-6 LOW PERMEABILITY OUTER W.G. APPROVED EQUAL. - O VAPOR BARRIER OF FIBER GLASS REINFORCED FILM LAMINATE SHALL COMPLETE THE COMPOSITE. 14.6 DUCT LINER OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO SPRINKLER HEADS IN COOLERS AND FREEZERS SHALL BE MODEL F3QR Q THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: CHROME PLATED AS MANUFACTURED BY RELIABLE AUTOMATIC SPRINKLER CO., DUCTWORK 18" WIDTH AND LARGER SHALL BE CROSS- ALL DUCTWORK DESIGNATED TO RECEIVE DUCT LINER SHALL A. EQUIPMENT CAPACITY(INPUT AND OUTPUT)AND REQUIRED INC.OR APPROVED EQUAL WITH A SPRINKLER GUARD TO PROTECT SPRINKLER - BROKEN OR RIBBED AND STIFFENED SO THAT IT WILL NOT BE COMPLETELY COVERED WITH LINER. TRAVERSE JOINTS MAINTENANCE ACTIONS. HEAD. GUARD SHALL BE SIMILAR TO SPRINKGUARD HEAVY DUTY WELDED "BREATHE", RATTLE, VIBRATE OR SAG. SHALL BE NEATLY BUTTED AND THERE SHALL BE NO INTER- B. EQUIPMENT OPERATION AND MAINTENANCE MANUALS. STEEL AND UL LISTED. RUPTIONS OR GAPS. C. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION U ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS, AND INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS,AND W SPRINKLER HEADS LOCATED LESS THAN 5'FROM HOOD SHALL BE HIGH CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING DUCT LINER SHALL BE CUT AS REQUIRED TO ENSURE OVER- CONTROL SEQUENCE DESCRIPTIONS; DESIRED OR FIELD-DETERMINED � WELDMENTS; MECHANICAL FASTENERS WITH SEALS, GASKETS, OR LAPPED AND COMPRESSED LONGITUDINAL CORNER JOINTS. SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL TEMPERATURE HEADS 1/2"ORIFICE, WITH A'K-FACTOR'OF 5.65,RATED AT N TAPES. TAPES MUST BE LISTED AND LABELED IN ACCORDANCE WITH UL DRAWINGS, AT CONTROL DEVICES,OR,FOR DIGITAL CONTROL 250-300 DEG. (MIN. IT FROM HOOD INSTALLATION CLEARANCE REQUIRED). J 181A OR UL 181B. ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS FASTENERS SHALL START WITHIN 3" OF THE UPSTREAM SYSTEMS, IN PROGRAMMING COMMENTS. ALL SPRINKLER HEADS THAT ARE TO REMAIN AND BE REUSED SHALL BE Q AND CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING AT TRAVERSE EDGES OF THE LINER AND 3" FROM THE LONG- D. COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO PROTECTED DURING CONSTRUCTION AND CLEANED THOROUGHLY TO INSURE �..� STATIC PRESSURES LESS THAN OR EQUAL TO 2"W.G. SHALL BE ITUDINAL JOINTS AND SHALL BE SPACED AT A MAXIMUM OPERATE. ALL PIPING SHALL WITHSTAND AIR PRESSURE TESTING THAT THEY ARE CLEAR OF PAINT AND DEBRIS AND ARE IN GOOD WORKING SECURELY FASTENED AND SEALED WITH WELDS GASKETS OR TAPES OF 12" o.c. AROUND THE PERIMETER OF THE DUCT. ELSE- PER GOVERNING PLUMBING CODE. Z WHERE THEY SHALL BE SPACED AT A MAXIMUM OF 18" o.c., CONDITION PRIOR TO PROJECT CLOSEOUT. Q INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION AND _ 3 ANSI/SMACNA 006-2010 HVAC DUCT CONSTRUCTION STANDARDS. EXCEPT THAT THEY SHALL BE PLACED NOT MORE THAN 6" UPON COMPLETION OF THE SYSTEM, THE INSTALLATION CONTRACTOR SHALL O = FROM A LONGITUDINAL JOINT OF THE LINER OR 12' FROM PROVIDE A MATERIAL TEST AND CLARIFICATION FORM TO THE BUILDING '� o c U MECHANICAL FASTENERS AND SEALS OR GASKETS MUST BE USED WHEN A CORNER BREAK. DEPARTMENT, THE FIRE MARSHALL, OWNER'S CONSTRUCTION COORDINATOR 3 ., Lf) W CONNECTING DUCTS TO FANS AND OTHER AIR DISTRIBUTION EQUIPMENT. AND OWNER'S INSURANCE CARRIER(IF REQUIRED)CERTIFYING SATISFACTORY ,_'^„ COMPLETION OF THE SPRINKLER SYSTEM INSTALLATION IN ACCORDANCE WITH APPROVED PLANS,CODES,PROCEDURES AND SPECIFICATIONS. M 10 O W HVAC + SPRINKLER KEYED NOTES O 5 Exea�r Oi W TYPE I EXHAUST HOOD WITH SUPPLY AIR PSP AND 3" INTERNAL STANDOFF WHICH INCLUDES A 1" LAYER OF u DUCT 18" EXH. DUCT 18" EXH.��� SULATION FACTORY INSTALLED TO MEET 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES.REFER DUCT DUC�� I' � F TO HOOD DRAWINGS FOR INFORMATION. �m o HVAC SYMBOLS LEGEND O LOCATION OF CONTROLS PANEL AND HOOD FIRE SUPPRESSION COMPONENTS ON WALL. SEE DETAILS AND Vd INFORMATION ON SHEETS M500 AND M510. c ° .D O ® SUPPLY AIR DIFFUSER RETURN AIR GRILLE R.A.G. RETURN AIR GRILLE B12. . O3 0%16"" - 16 GAGE BLACK IRON HOOD EXHAUST DUCT FROM EXHAUST HOOD CONNECTION. (TYPICAL OF 2) PROVIDE •tea' =�==e J VOLUME DAMPER —G— GAS LINE '-0"AT A.F.F. 126X26 MUA DUCTI TRANSITION AND ROUTE 18%18"" EXHAUST DUCT UP THRU ROOF TO NEW EXHAUST FANS (EF-1 AND EF-2). DUCT T.G.C.TENANT GENERAL CONTRACTOR —D— CONDENSATE DRAIN LINE DIFF. DIFFUSER 12"X12" ACCESS SHALL BE INSTALLED IN 2-HOUR RATED ENCLOSURE (DUCT WRAP). INSTALL DUCTWORK TO AVOID INTERFERENCE °^^ M.D. MANUAL DAMPER 12"X12"AC ESS PANEL WITH EXISTING TRUSS. SEE DETAILS AND INFORMATION ON SHEETS M400, M500, AND M510 FOR EQUIVALENT G.C. GENERAL CONTRACTOR M� MOTORIZED DAMPER PANEL 20""xi6" EXIT. FIRE-WRAP INSTALLATION. PERFORM GREASE DUCT PRESSURE TESTING. REFER TO SHEET MEP100 FOR LOCATION. LL R.L. REFRIGERANT LIQUID LINE F.C. FLEXIBLE CONNECTION R.D. REFRIGERANT DISCHARGE LINE ❑S SMOKE DETECTION DEVICE 20""x16" EXH. DUCT y AIR DEVICE TYPE T THERMOSTAT DUCT TOP OF REMOTE MANUAL PULL STATION FOR HOOD FIRE SUPPRESSION SYSTEM FOR NEW HOOD. INSTALLED BY "K.E.S."AS R.S. REFRIGERANT SUCTION LINE 0 AIR VOLUME IN HOOD 9-2 4 O.A. OUTDOOR AIR SD SMOKE DETECTOR CUBIC FEET/MINUTE (CFM) 28"x12" SHOWN AT 44"A.F.F. AND RI LEAST 10'-0" BUT NO MORE THAN TO 20'-0"AWAY FROM HOOD. VERIFY FINAL F N R.A. RETURN AIR ® SPRINKLER HEAD, SEMI-RECESSED MUA (TYP.) HOOD EXHAUST PLACEMENT WITH LOCAL JURISDICTION. r mS.A. SUPPLY AIR TE TOILET EXHAUST mSPRINKLER HEAD, PENDENT PROVIDE TRAPEZE SUPPORT FOR HOOD HANGING ROD TO AVOID INTERFERENCE WITH HOOD HANGING AND DUCT INSTALLATION. ELEVATIONROUTE WATER HEATER 3" PVC FLUE VENT AND 3" PVC COMBUSTION AIR INTAKE OUT UP THRU ROOF. TERMINATE PERMANUFACTURER'S INSTRUCTION. WATER HEATER IS FACTORY SUPPLIED WITH STANDARD TERMINATION 45 DEGREE SPRNVKLER NOTES' ELBOW WITH PART #9006027015 RECESSED BIRDSCREEN. OBTAIN FROM G.C./P.C. IF FACTORY TERMINATION NOT 3w USED, PROVIDE BIRDSCREEN EQUAL TO NORITZ VT3-PVCS. REFER TO SHEET MEP100 FOR CONTINUATION. REFER TOSPRINKLER CONTRACTOR SHALL PROVIDE NEW TO ACCOMMODATE PLUMBING FIXTURE SCHEDULE ON SHEET P100 FOR INFORMATION. NEW PARTITION LOCATIONS. PROVIDE HEADS PER LOCAL CODE NOTE: REQUIREMENTS. > -REFER TO SHEET MEP100 FOR HVAC ROOFTOP EQUIPMENT. 1 O7 DENOTES DUCT DROP DOWN THRU ROOF FROM ROOF MOUNTED EQUIPMENT. REFER TO SHEET MEP100 FOR -VERIFY THAT TYPE 1 HOODS WILL BE INTERCONNECTED WITH CONTINUATION. TRANSITION SUPPLY AND RETURN AIR DROP FROM RTU-1 AND RTU-2 IN CURB PRIOR TO ROOF SPRINKLER CONTRACTOR SHALL PROVIDE DRY TYPE SPRINKLER HEAD EQUIPMENT BELOW OR PROVIDE A THERMISTOR. PENETRATION. WITH A LISTED AND APPROVED SPRINKLER GUARD FOR IMPACT -ROOF LOADS FOR RTUS TO DE PROVIDED BY TRUSS PROTECTION IN WALK-IN COOLER/FREEZER. > ENGINEERING ON SITE. ® FURNISH AND INSTALL SMOKE DETECTOR IN THE RETURN AIR DUCT INSIDE THE ROOFTOP UNIT. ENSURE SMOKE DETECTION DEVICE IS TO BE INTERLOCKED WITH ROOFTOP UNIT SO AS TO SHUT UNIT DOWN UPON THE DETECTION OF SMOKE. SYSTEM SHALL BE EQUIPPED WITH AN AUTOMATIC SHUTOFF. AUTOMATIC SHUTOFF SHALL BE ACCOMPLISHED BY INTERRUPTING THE POWER SOURCE OF THE AIR-MOVING EQUIPMENT UPON DETECTION OF SMOKE. / 3 O9 ONEYWELL PRESTIGE IAQ KIT MODEL YTHX9421R7001WW PROGRAMMABLE THERMOSTAT FOR RTU-1 AND RTU-2. / ROVIDE LOW VOLTAGE WIRING AS RECOMMENDED BY THE ROOFTOP UNIT MANUFACTURER. 0 10 HONEYWELL REMOTE SENSOR MODEL C7189U1005 FOR HONEYWELL THERMOSTAT SERVING RTU-1 AND RTU-2. ,. INSTALL AT CEILING AS SHOWN. PROVIDE LOW VOLTAGE WIRING AS RECOMMENDED BY THE ROOFTOP UNIT MANUFACTURER. 2 0000 z2 >: F PROVIDE SIMPLEX GRINNELL REMOTE ANNUNCIATION AND KEYED RESETS MODEL 4098 9842 CONTROL STATION OR 00 APPROVED EQUAL. INTERLOCK WITH EACH DUCT SMOKE DETECTOR WITH THE ROOFTOP UNIT OF THE AREA SERVED. �( 30 ) DUCT SMOKE DETECTOR TROUBLE CONDITIONS SHALL ACTIVATE A VISUAL OR AUDIBLE SIGNAL AND SHALL BE IDENTIFIED AS AIR DUCT DETECTOR TROUBLE. THE ENUNCIATOR SHALL BE EQUIPPED WITH KEY-OPERATED DETECTOR '..��..7. TEST AND RESET FUNCTIONS. TENANT'S CONTRACTOR SHALL INSTALL AT WALL ABOVE THERMOSTATS OF OFFICE AREA 00 N '.fF. AS SHOWN. GC TO COORDINATE LOCATIONS OF THERMOSTATS IN OFFICE TO NOT CONFLICT WITH WALL CABINETS AND 0 s N � ';� ;' •'. COUNTER. RTU-2�l 0 12 NEW LOW PRESSURE SUPPLY AND RETURN AIR DUCT WITH Y"THICK EXTERNALLY Y'LB. DENSIN INSULATION MIN. R-6 IN AREAS ABOVE CEILING SUPPLIED AND INSTALLED BY MECHANICAL CONTRACTOR. PROVIDE TRANSITIONS ASMEN L _J REQUIRED. DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. f�22x16 26 18 13 PROVIDE VOLUME DAMPERS AT ALL DUCT BRANCH TAKE-OFFS. SEE DETAIL ON SHEET M400. (TYPICAL) ,�� SD 14 DENOTES SIDEWALL MOUNTED SUPPLY AIR GRILLE. REFER TO AIR DEVICE SCHEDULE ON SHEET M300 FOR E 2N �.� +. �'• .`.; INFORMATION. 50 :;..., .::. :.: ..'C> >. au 15 PROVIDE A RECTANGULAR BOOT WITH A ROUND CONNECTION SIZED AS SHOWN FOR SIDEWALL SUPPLY AIR GRILLES. ® " .. •:p; ® �`.•8.'' 16 CONTRACTOR SHALL PAINT THE SHEET METAL BACKING BLACK AT THE RETURN AIR GRILLES IN THE DINING ROOM. m 1 - 17 TOILET EXHAUST DUCT UP THRU ROOF BETWEEN TRUSS. PROVIDE BIRD SCREEN AT EXHAUST DISCHARGE ABOVE ROOF. REFER TO SHEET MEP100 FOR CONTINUATION. REFER TO SHEET MEP100 FOR CONTINUATION. " V0 O 14 m PROVIDE 2'x2' ACCESS PANEL WITH PHENOLIC PLASTIC NAMEPLATE FOR ABOVE HOOD ACCESS OF THE GREASE DUCT O f1• O 0 ��' CLEANOUT. COORDINATE LOCATION WITH ALL TRADES. FIELD VERIFY LOCATION. IA E_^,� D • ® ® U I' 19 PROVIDE PENDENT SPRINKLER HEADS IN LAY-IN CEILINGS PER NFPA 13. ,STLF�rC/2 PROVIDE SEMI-RECESSED SPRINKLER HEADS IN AREAS AT TECTUM CEILING PER NFPA 13. c o {,JJ• x -- - ----- 21 PROVIDE PENDANT TYPE SPRINKLER HEAD INSTALLED IN GYP. CEILING. a 9316 -O O A - �2 PROVIDE DRY TYPE SPRINKLER HEAD WITH A LISTED AND APPROVED SPRINKLER GUARD FOR IMPACT PROTECTION IN E 5 26 6 �y ;,�' O ® �Typ) WALK-IN COOLER/FREEZER. 09�TF OF\Q P�G FIRE SPRINKLER CONNECTION. FIELD VERIFY SIZE AND LOCATION. 9ELL�i.G _ __ ® REFER TO ARCH SHEETS FOR EXACT PLACEMENT OF EQUIPMENT AND MATERIALS AND COORDINATE THE INSTALLATION 18 K �1. ® 7 OF DUCTWORK WITH ARCHITECTURAL FEATURES AND LIGHTING. SD 1 18"x10"" - 16 GAGE BLACK IRON HOOD EXHAUST DUCT FROM EXHAUST HOOD CONNECTION. PROVIDE TRANSITION AND ROUTE 1 6"06" EXHAUST DUCT UP THRU ROOF TO NEW EXHAUST FANS (EF-3). DUCT SHALL BE INSTALLED IN J N 5 4 0 ..'\✓,Y _- ___ 2-HOUR RATED ENCLOSURE (DUCT WRAP). INSTALL DUCTWORK TO AVOID INTERFERENCE WITH EXISTING TRUSS. SEE ig ® DETAILS AND INFORMATION ON SHEETS M400, M500, AND M510 FOR EQUIVALENT FIRE-WRAP INSTALLATION. PERFORM o (T,P 25 7 , _ - - t -_- GREASE DUCT PRESSURE TESTING. REFER TO_SHEET MEP100 FOR LOCATION. LlJ ;:`. _ ' y 6 EXHAUST FAN TO BE INTERCONNECTED WITH LIGHTS TO RUN WHILE RESTROOM IS OCCUPIED. W cl) zz 1 I 1 0.®.. s sJo o a 862 0 H W 122x6 M LU H 550C LJ o H °° H MECHANICAL GENERAL NOTES Ir cS m 100 l l„...:U.-, :-11----.fl------J,I:----lk.: .-JJ-,-„I II A 1. THE MECHANICAL CONTRACTOR SHALL VERIFY THAT ALL EQUIPMENT, AS SHOWN ON THESE DRAWINGS, WILL NOT CO ODNFLICT WITH ANY DRAINS, SCUTTLES, JOINTS, VENTS, PIPING OR EQUIPMENT. � II II II II II I1' I1 11 - - 2. ALL ROOFTOP EQUIPMENT SHALL HAVE MANUFACTURER SUPPLIED ROOF CURBS AND PIPE SEALS. ° ® 3. THE MECHANICAL CONTRACTOR SHALL PROVIDE COMPLETE INFORMATION AND COOPERATION TO THE OTHER - ® - CONTRACTORS AND TRADES AS REQUIRED FOR COMPLETION AND COORDINATION OF THE COMPLETE PROJECT. II 4. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ADMINISTERING ALL WARRANTIES ON EQUIPMENT INSTALLED Z m B ® ® II BY THE CONTRACTOR. THIS INCLUDES, BUT IS NOT LIMITED TO REFRIGERANT LINES, FLUES, TENANT FURNISHED Z Q 20 2Oxi 20 EQUIPMENT, ETC. Sx14 14x1 - 0 5. ALL OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 10'-0" FROM ANY EXHAUST FAN, FLUE OR PLUMBING VENT. p 0 O O 6. PROVIDE VIBRATION ISOLATION DEVICES AND FLEXIBLE CONNECTIONS TO ALL MOVING MACHINERY, EXCEPT EXHAUST O A. p '� O 14 0 -- FANS (UNLESS OF NOTES). J ---I� B TYP ) 21 200 lyp( 7. ALL FLEXIBLE DUCTS SHALL BE SUPPORTED EVERY 4'-0" WITH 2"" WIDE GALVANIZED STEEL BANDS WITH A MINIMUM L.L II 300 B P ( ) OF ONE PER EACH SECTION OF FLEXIBLE DUCT. NO FLEXIBLE DUCTWORK SHALL BE ALLOWED ABOVE INACCESSIBLE J t CEILINGS. Z, U JC 8. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS IN INCHES. 9. THE MECHANICAL CONTRACTOR SHALL COORDINATE ALL DUCT AND DIFFUSER LOCATIONS WITH SPRINKLER PIPING, Q =; TTI 7L-7 SPRINKLER HEADS AND LIGHTING LAYOUTS AS REQUIRED. O 04 10. THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR AND OTHER TRADES, ALL ? m w k..k..k REQUIRED OPENINGS AND EXCAVATIONS. a w N- 11.ALL REQUIRED OPENINGS IN FOUNDATIONS, FLOORS, WALLS AND ROOF SHALL BE CONSTRUCTED INTO THE STRUCTURE al MECHANICAL FLOOR PLAN WITH THE USE OF SLEEVES, CURBS, ETC. CUTTING AND PATCHING SHALL BE HELD TO A MINIMUM. � r M//�L O O scw 1/4• - -v Q Y AIR DEVICE SCHEDULE e NOTES HVAC SYMBOLS LEGEND E"act. PLAN FACE NECK FLEX TYPE s & MARK MODEL NO. SIZE SIZE SIZE ® SUPPLY AIR DIFFUSER Z RETURN AIR GRILLE R.A.G. RETURN AIR GRILLE R A 5 *TITUS 30ORL 16"xl0" 14"x8" NA DOUBLE DEFLECTION BAR SUPPLY 2,3,5 J VOLUME DAMPER -G- GAS LINE u V B 6 *TITUS PAS 16"x16" 8" RD. 8" RD. PERFORATED SUPPLY DIFFUSER 2,3,5 T.G.C.TENANT GENERAL CONTRACTOR -D- CONDENSATE DRAIN LINE DIFF. DIFFUSER o C 2 *TITUS PAS 12"xl2" 6" RD. 6" RD. PERFORATED SUPPLY DIFFUSER 2,3,5 G.C. GENERAL CONTRACTOR M.D. MANUAL DAMPER M MOTORIZED DAMPER c R.L. REFRIGERANT LIQUID LINE S SMOKE DETECTION DEVICE F.C. FLEXIBLE CONNECTION D 2 *TITUS PAS 16"x16" 12" RD. 12" RD. PERFORATED SUPPLY DIFFUSER 1,3,5 R.D. REFRIGERANT DISCHARGE LINE A Vv IR DEVICE TYPE c E 4 *TITUS PAR 24"x24" 14" RD. 14" RD. PERFORATED SUPPLY DIFFUSER 2,3,4,7 R.S. REFRIGERANT (D THERMOSTAT T SUCTION LINE AIR VOLUME IN F � < O.A. OUTDOOR AIR SD SMOKE DETECTOR CUBIC FEET/MINUTE (CFM) •mo ow . . , , R.A. RETURN AIR ® SPRINK 1 *TITUS PAS 24"x24" 12" RD 12" RD PERFORATED SUPPLY DIFFUSER 234 LER HEAD, TECTUM � d G 1 1 *TITUS PAS 24"x24" 6" RD. 6" RD. PERFORATED SUPPLY DIFFUSER 2,3,4 S.A. SUPPLY AIR TE TOILET EXHAUST 6°A�q o 0 SPRINKLER HEAD, PENDENT _ H 2 *TITUS PAR 12"x24" 6" RD. 6" RD. PERFORATED TRANSFER GRILLE 3,4,6 © HUMIDISTAT g WE 2 *TITUS PAR 24"x24" 20" RD. 20" RD. PERFORATED RETURN GRILLE 3,4 J 2 *TITUS PAR 24"x24" 16" RD. 16" RD. PERFORATED RETURN GRILLE 3,4 EOUIPMENT AIR BALANCE SCHEDULE c3 an K 0 *TITUS PDR 48"x24" 16" RD. 16" RD. PERFORATED RETURN GRILLE L 0 *TITUS PDR 24"x24" 16" RD. 16" RD. PERFORATED RETURN GRILLE 3,4,8 UNIT AREA SUPPLY AIR RETURN AIR OUTSIDE AIR MAKE-UP AIR EXHAUST AIR PRESSURE tD m a z SERVED CFM CFM CFM CFM CFM CFM = z m rn NOTES: L7 -m m ut ro w RTU-1 DINING 3000 2250 1250 +1250 1. PROVIDE VERTICAL PATTERN CONTROLLER m J min 2. REFER TO PLAN FOR THROW PATTERN ORIENTATION RTU-2 KITCHEN 4000 3250 800 +800 tp 3. PROVIDE MANUAL VOLUME DAMPER �w 3 w -m C 4. FRAME SHALL FIT LAY-IN CEILING MODULE 'z 5. FRAME SHALL FIT GYPSUM BOARD CEILING SURFACE i 3 / MAU-1 HOOD 6480 +6480 a 6. TRANSFER GRILLE 7. DOWN DISCHARGE TYPE SUPPLY AIR DIFFUSER EF-1 HOOD-1 3000 -3000 8. PAINT THE SHEET METAL BACKING BLACK AT THE RETURN AIR EF-2 HOOD-1 3000 -3000 GRILLES IN THE DINING ROOM. 9. FABRICATE PLENUM BOX FOR RETURN AIR GRILLE IN FIELD. REFER TO MECHANICAL EF-3 HOOD-2 2000 -2000 FLOOR PLAN FOR SIZE. EF-4 TOILET 150 -150 * OR EQUAL APPROVED IN WRITING BY OWNER/OWNER'S REPRESENTATIVE I - EF-5 TOILET 150 -150 TOTALS 7000 5500 1870 6480 8300 CFM +230 Mechanical Ventilation Schedule Exhausted EKhaud, Required Required Breathing Zone Air zwte Supplied FExnaust ALrHoaa .= NEW ROOFTOP UNIT SCHEDULE (RTU-I-DINNING) Floor Area Outdoor Air Outdoor Air Zone Outdoor Distribution Outdoor Outdoor Air Supply Air Airflow Rate Required Supplied Room 0d) Oormpama (Cim/person) (CFM/R2) Air Effectiveness Air(CFM) (CFM( (CFM) CFM/Ft2 (CFM) (CFM) TOTAL MIN. OUTSIDE FILTERS DINING 1111 77 Z5 0.18 777.48 0.8 971.9 750 3000 MFR. MODEL N0. UNIT WT. SIZE VOLTS HZ PH MCA MOCP AIR CFM N0. SIZE TYPE KfTCHEWSERVING 750 8 7.5 0.18 196.08 OMB 245.1 463 281 0.70 5292 mm 1056 7.5 CLEANING/STORAGE 410 5 5.0 0.06 49.60 0.8 620 210 1050 TRANE YHC092 LBS. TONS 208 60 3 42.4 50.0 1250 4 20x25x2 T/A OFFICE 55 1 50 000 830 88 10.4 20 100 - - - TOTAL COOLING CAPACITY EER GAS HEAT CAPACITY AFUE% EVAP. COIL EVAPORATOR CFM SENSIBLE TOTAL INPUT OUTPUT SIZE ROWS FAN MOTOR Totals 1289.3 78.69 90.55 12.6 160 112 80 12.36 3000 MBH MBH MBH MBH SQ.FT. 3 2.75 HP NOTES: 1. INCLUDES FAN AND MOTOR HEAT. 2. CONTRACTOR SHALL PROVIDE HONEYWELL PRESTIGE IAQ KIT MODEL YTHX9421R7001WW. 3. BLOWER FAN MAINTAINS CONTINUOUS OPERATION DURING OCCUPIED HOURS. 4. INCLUDE FACTORY INSTALLED LOW LEAK ECONOMIZER WITH FACTORY INSTALLED OPTION FAULT DETECTION & DIAGNOSTICS (FDD) WITH BAROMETRIC RELIEF. 5. INCLUDES 14" ROOF CURB. 1 6. UNIT EQUIPPED WITH MULTI-SPEED AIR VOLUME BLOWER. BOTH THE LOW SPEED Habit HVAC system T&B Soope of Work 2015 MINIMUM POSITION AND THE HIGH SPEED MINIMUM POSITION SETTING SHALL BE All third party air balance companies used on Habit projects to be either NEBB or AABC certified and have cument certification and BALANCED TO CFM SPECIFIED. applicable licensing.Note that complete and full air balance applies to ALL equipment servicing Habits Tl space including HVAC, 6. INCLUDES DISCONECT SWITCH MAU,exhaust hood&fans,restroom exhaust fans and PCU units(where occurs),regardless of who supplies equipment. 7. INCLUDES NON-POWER CONVENIENCE OUTLET 1.Inspection: 8. INCLUDES FACTORY INSTALLED RETURN SMOKE DECTECTOR. .Inspect general condition of HVAC systems and installation.Record equipment data and compare with design LOAD COMPONENT SUMMARY 9. PROVIDED AND INSTALLED BY TENANT G.C. requirements 10. CONDENSATE OVERFLOW PROTECTION DEVICE TO BE PROVIDED ON UNIT. 2.Testing:Test HVAC systems for proper operation •Inspect Rooftop units for proper operation: •Veriry fan rotation •Measure/record motor amperage •Measure/record voltage COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK 5�01IAL EA� •Verify sequence of operation(test heating/cooling modes) P ........ maRc m4 MwBc samo M .anng D.al9n !G5 '✓(�1 •Set T-$tatsto Habit standards: BaOvnke.11 OADBhNBIHR:93r65156 OAOB:peaksl OADB:�0 ROOFTOP UNIT SCHEDULE (RTU-2-KITCHEN) �eDtST. E '2 O Occupied-7:30 a.m.to 11:30 p.m.-74 degrees cool 68 degrees heat-Fan setting-ON Unoccupied-11:30 p.m.to 7:30 a.m.-80 degrees coal 60 degrees heat-Fan setting-AUTO sena.swet. sane l.niet wa. of twat a..am.e orrol.l score aen. _en.or role. TOTAL MIN. OUTSIDE FILTERS v •van thatall units have spare fan belt located inside unit awn awm scam IxI a:b lzI elwn e.wn 0q MFR. MODEL N0. VOLTS HIS PH MCA MOCP ry UNIT WT. SIZE AIR CFM N0. SIZE TYPE 9316 O •verify duct smoke detectors are installed and connected(resets to be located in office) nvvl p Loam aempaw4d. N esxwresolar o a a o a o ensxyllresolar c o ono 1619 10 3 20x25x2 J, ,L. •Verify and set economizer's to engineered drawing specifications.See Mechanical sheets for data TRANE YHC120 208 60 3 46.1 60 800 T/A sue cons o 0 0 0 0 o s_9acona o 0 00o LBS. TONS 2 20x30x2 t7 9� �QQ-'f!/2.1.Make Up Alr Unit(MAU) cons t5,on 0 5oz7 a e76g 7 R com -13076 -tao76 630 •InspectirUni uniAU)proper operation: class soar 1d,a91 a 14;091 9 35}3a ze cla..soar c o o.00 TOTAL COOLING CAPACITY GAS HEAT CAPACITY EVAP. COIL EVAPORATOR q�' of P� Gla rrrCona 3.352 a 3.352 2 -1,360 1 Giv,worarCO -16.896 -16,8s6 886 EER AFUE% A G •Veriry fan rotation waucrm 1 a 1 e 77z 7 wallcnnd -11 09 11 09 4so CFM SENSIBLE TOTAL INPUT OUTPUT SIZE ROWS FAN MOTOR FLL R• /5/1•Measure/record motor amperage p.ninrwDppr s'�a 9'73a o a' c o p.neir,vor« '10 '10 so0 103.2 106.9 12.4 200 160 80 16.65 •Measure/record voltage u o ^ 1 4000 MBH MBH MBH MBH S,,F 4 2.75 HE •Veriry sequence of operation(test heating/cooling modes) ` •Set evaporator thermostat adjustment per CaptiveAire specifications Sue Tdt lPl 45,204 0 d5,204 20 53,083 42 sue total== -Be,20t -8814 ,20t0 2874 .01 NOTES: 3.Balance and Verify: n..ma .de m•m.l Lp.d• 1. INCLUDES FAN AND MOTOR HEAT. •Balance the kitchen exhaust system for proper heat and smoke capture removal.Verify proper performance with 1u9nm Lo 14,7a3 s,681 18417 11 1473a 11 ughre o 0 0.00 2. CONTRACTOR SHALL PROVIDE HONEYWELL PRESTIGE AD KIT MODEL YTHX9421R7001WW. J smoke emitter tests. pane. 34.100 o 34:1. 27 n:o5o 13 pnplv o o oto 3. BLOWER FAN MAINTAINS CONTINUOUS OPERATION DURING OCCUPIED HOURS. •Balance the air conditioning&heating units for optimal air distribution and comfort 4s,683 0 43,sm a 4a,es3 se star o o o.w 4. INCLUDE FACTORY INSTALLED LOW LEAK ECONOMIZER WITH FACTORY o sm rotor--=> 9z,ee3 3,ee3 9e,eea 59 7s,633 se sae twat=> 0 0 0.to INSTALLED OPTION FAULT DETECTION & DIAGNOSTICS FDD WITH BAROMETRIC RELIEF. •Correa fan rotation,belt tension,sheave alignment,damper position an all units.Check for clean filters and coils ( ) M •Balance the building proper fresh air quantities and pressurization in all areas of the store. e•Illnp Loed o 0 0 o a o Caling Lwe e o o.o0 5. INCLUDES 14" ROOF CURB. ld.l 0 0 2a,aae 13 a 0 venuullan Ldad 0 -e2,ss1 3au 6. UNIT EQUIPPED WITH MULTI-SPEED AIR VOLUME BLOWER. BOTH THE LOW SPEED Ay AIr1Tn.�a.., o g o a c Aal A,Tran.X_ c 0 o w Cn 4.Measurements: slang o 0 o.mndrsl.1 a -98.131 -98.131 seas MINIMUM POSITION AND THE HIGH SPEED MINIMUM POSITION SETTING SHALL BE •Measure and record airflow,motor speed,motor amp draw,and compare to nameplate data and specifications. a�u�a�sl�ne o a o a o Exhau 14- o o.00 BALANCED TO CFM SPECIFIED. r -030 -03a 4 oA Pr.n.,l oln. o 0.00 6. INCLUDES DISCONECT SWITCH W S.Adjustments: B. .... t,g50 Adds-I fth 1 0 0.00 o g 0 Aeall..nal R.n.. o 0.00 7. INCLUDES NON-POWER CONVENIENCE OUTLET of •Reduce fan speeds when possible to save fan energy and conditioned air,and reduce noise levels,while maintaining ova x..�vx�p a a o 8. INCLUDES FACTORY INSTALLED RETURN SMOKE DECTECTOR. W M comfort. unaealr sapmpxap g 0 unmmr savor Pxap o to •Balanced system needs to maintain positive building pressure once complete s.Pply a o o sappl-L.-g. o 000 9. PROVIDED AND INSTALLED BY TENANT G.C. j 1b crane mm••> 137.887 Zess isa me 1mm i.al. 10o,ag cndrpt l••> -164,332 sa6,eea 1xica 10. CONDENSATE OVERFLOW PROTECTION DEVICE TO BE PROVIDED ON UNIT. P in L,L( 6.Tolerance:•HVAC system airflows to be balanced within+/-5%of design. 7.Performance Verification: EXHAUST FAN SCHEDULE EF-4+ EEO Upon completion of the balance,veriry HVAC performance via slight posi0ve building pressure,occupant comfort,andcapture and containment of kitchen hoods WEATHER TOTAL S.P. MOTOR NOMINAL MANUFACTURER MODEL NO. IN WG. DRIVE HP RPMCFM SONES VOLTS PH HZTd 8.Documentation&clarifications: •Submit a IN EBB or AABC Certified test and balance report with findings including the equipment data,measurements, GREENHECK SIP-B150 0.375" DIRECT 128 W 1,050 150 3.5 120 1 60 list of deficiencies,and recommendations.This information to be submitted directly to the architect of record for Location Boise,Idaho comment and approval by their respective mechanical engineer.Habit to be copied on these Latitude 43.5 deg NOTES: correspondences. Longitude 116.0 deg • Provide equipment commissioning reports to architect of record.Habit to be copied on these correspondences. Time Zone 7 1. PROVIDE BACKDRAFT DAMPER. •Installing HVAC contractor cannot self-certiry or be the preforming agent of T&B Elevation 2,842 ft 2. INTERLOCK FAN WITH LIGHTSWITCH. •IfT&B report is incomplete of fails review,Habit at its own discretion may choose to have the entire system Barometric pressure 26.8 In.Hg retested by an accredited air balance company of our choosing.The cost of said re-test will come at the direct expense of the contracted GC of the project. Air density 0.0687 Ib/cu R Air specific heat 0.2444 Btu/Ib°F _ g N Density-specific heat product 0.9968 Blu/ham°F W Latent heat factor 4,396.6 Btu-min/h-cuft BALANCE REPORT DUE AT FINAL o Z J Enthalpy factor 4.0861 lb-min/hr-cu It Summer design dry bulb 94.0 °F Q summer signdygn b bulb 10.0 'F CAPTURE & CONTAINMENT AND LIGHT = Summer rclea dry bulb 1.10 °F Summer clearness number 1.10 Win ter rgrounclearness number 0.B0 TESTS REQUIRED FOR HOOD N Summer ground reflectance 0.20 Winter ground reflectance 0.20 J Carbon Dioxide Level 400 plan Design simulation period January•December U Cooling load methodology TETD-TAT Z Heating load methodology UATD 3 (UJ G M300 ROOF JOIST TWO (2) LAYERS OF 3M FIRE BARRIER DUCT WRAP 615+, 1 1/2" N xs6 THICK WITH MIN. 3" PERIMETER & LONGITUDINAL OVERLAPS. e 6e PROVIDES TWO HOUR FIRE RESISTIVE RATING AND ZERO CLEARANCE TO COMBUSTIBLES AT OVERLAP OR COLLAR. 3M FIRE c: V BARRIER DUCT WRAP IS LISTED BY INTERTEK 3MU/FRD 120-18 a (ASTM E2336). INSTALL PER MANUFACTURER'S INSTRUCTIONS. bo 0 C STEEL BANDING V c LL -HANGER WIRE 1/2"W MINIMUM �� a 3" MIN. LONGITUDINAL OVERLAP AT BLANKET JOINT oz4 3" MIN. PERIMETER - - SHEET MTL. DUCT HANGER OVERLAP AT BLANKET JOINT \�T RECTANGULAR DUCT EXTERNAL INSULATION SHALL CONTINUOUSLY WELDED BE RUN CONTINUOUS THRU HOOD EXHAUST DUCT li 1 1/2 ° m HANGERS 10 1/2" �m mai a RECTANGULAR DUCT HANGER DETAIL 1 1/2' 1? SCALE NONE 1 0 1/2" 21rj 55 NOTES: i 3 w m ' 1.BANDING REQUIREMENTS: USE STEEL BANDS A MAXIMUM 2" FROM N x 3 RAIN CAP BLANKET EDGE AND SPACED A MAXIMUM OF 10 1/2" ON CENTER. a 2.WRAP GREASE DUCT CONTINUOUS AS SHOWN FROM CONNECTION AT FAN THROUGH CURB AND EXTEND 18" MIN. BELOW ROOF DECK. STORM COLLAR 3.FOR HORIZONTAL RUNS OF EXHAUST DUCTS PROVIDE TYPICAL THIMBLE TRAPEZE SUPPORT SYSTEM WITH 1/2" HANGER RODS A MAXIMUM OF 6" FROM INSULATION EDGE. TRAPEZE SUPPORTS SHALL BE SPACED A ROOF MAXIMUM OF 60" ON CENTER FROM CENTERLINE OF VERTICAL EXHAUST DUCT. 4.SLOPE HORIZONTAL EXHAUST DUCT RUNS A MINIMUM OF 1/4" PER 10"m FOOT (2% SLOPE) TOWARDS EXHAUST HOOD. 5.PROVIDE INSULATED ACCESS DOORS OR PANELS FOR CLEANING AND INSPECTION OF DUCT. PROVIDE AN APPROVED SIGN ON EACH ACCESS METAL TOILET DOOR OR PANEL WHICH READS "ACCESS PANEL - DO NOT FLEX 8"0 EXHAUST OBSTRUCT". FAN \ CAP / CEILING REFER TO 3M FIRE BARRIER DUCT WRAP 615+ PRODUC DATA SHEET AND INSTALLATION GUIDE PAGE 4. NOTES: 1. SEE FLOOR PLAN FOR DUCT DIMENSIONS. 2. ELECTRICIAN TO WIRE FANS IN PARALLEL WITH RESTROOM LIGHT FIXTURES. aTOILET FAN EXHAUST DETAIL a GREASE DUCT DETAIL SCALE- NONE SCALE NONE A SIGN SHALL BE PLACED ON ALL ACCESS PANELS STATING THE NOTE: ALL DUCTWORK ABOVE ROOF TO BE SEALED 100% AIR AND WATER TIGHT. FOLLOWING: MIN. 24 GA. G.I. CAP FLASHING "ACCESS PANEL-DO NOT OBSTRUCT" SECURE W/SCREW THRU 5/8" CDX PLYWOOD STEEL/NEOPRENE WASHER AS (2)2x12, RIP FOR LEVEL GASKET NEEDED FOR PROPER PLATFORM SEALANT 2x6 S 0 ENT(4 SIDES) ®16"O.C. BITUTHENE CAP SHEET ACCESS OPENING OVER TOP OF SLEEPER -- EXTEND DOWN SIDES BY 2" 1/4"0 THREADED RODS CONTINUOUS o z BASE FLASHING \ WELDED TO GREASE WELDED SEAM �^ DUCT 10" MAXIMUM COUNTER FLASHING__ z F o FIBER CANT STRIP W/ 4" SPACING BY CONTRACTOR SPOT WELDED o LEGS - NAIL TO PLYWOOD z AT 12 O.C. WASHER TONAL WOOD NAILER O1'�o ROOFING MATERIAL (TYP. OF 4) ��g9G�S^r�ElE�Mc�2 1/8" THICK STEEL J CURB a PLATE BY HC INSULATION ZGREASI 93160 DUCT. REFER � Q 9 TO PLAN FOR SIZE `�6 \ -9 of X PGj 7 4 \ 9FLL R. /5/1 NOTE: I,(/ EXISTING SET SUPPORTS ON SOLID 10d ® 6" O.C. (TYPICAL) (6ESSGAUGE) OVER ROOF DECK --- �,_........__ REPAIR OF BUILT-UP NON-RIBBED NEOPRENE, AND 2x6 BLOCKING J ROOFING BY CONTRACTOR SECURE LAG BOLTS THROUGH STEEL/NEOPRENE WASHER 1/4"m WING NUT o (TYPICAL OF 4) M W a CURB DETAIL OF DUCT THRU ROOF al ROOF PLATFORM SECTION al SCALE- GREASE DUCT ACCESS PANEL DETAIL w SCALE: NONE 8CALE: NODE rn w M H .1 j co W JD W m¢ o vS U PROVIDE POSITIVE EXPOSED DUCTWORK DRAINAGE ON TOP OF PLYWOOD W>- Z J STRAP DUCT TO ANGLE IRON DUCT (1":12") SHEATHING U rn 07 16 GA. BLACK IRON DUCT TRUSS U.N.O.S OR TRUSS U.N. 2" WIDE MIN. DUCT STRAP ALL STEEL SUPPORT SHALL BE 48" O.C. MAX. HOT DIPPED GALVANIZED AFTER EXTERIOR POLYURETHANE OR FABRICATION POLYSTYRENE (MIN. R-8.0) • RIGID ROUND METAL DUCT ALU MAGUARD BY POLYGUARD 60 MIL EXTERNALLY INSULATED ALL WELD ANGLE SUPPORT UV RESISTANT WEATHERPROOFING ON JOIST HANGERS - TOP AND SIDES OF DUCT ZPENING (TYP.) - SEE NOTE WELD PLATE TO PER PLANS BELOW _ ANGLE IRON INSULATION PINS 12" PATE EQUIPMENT �j ? DOUBLE 2x HEADER SUPPORT iv IL SAME SIZE AS JOIST _ (n OR RAFTER U.N.O. J_ PLWD. EDGE NAILING INSULATED FLEXIBLE DUCT VAPORGUARD BY POLYGUARD 5 (EN.) AROUND MAX. LENGTH 8'-0". SPIN-IN FITTING Q MIL VAPOR BARRIER ON BOTTOM ROOF OPENING WITH BALANCING OF DUCT VOLUME DAMPER DAMPER (DAMPER LJ,J NOTE: (FOR FINAL BALANCE USED FOR ROUGH METAL SUPPLY DUCT Q ADJUSTMENT) BALANCING EXTERNALLY INSULATED HANGERS SHALL BE "SIM PSON" STANDARD "U"" CP ROOF. ) J DEL. JOIST OR RAFTERS SHALL BE JOINED TOGETHER AS U NOTE: FOLLOWS: 1. CONTRACTOR SHALL VERIFY ROOF CONSTRUCTION IN FIELD TO DETERMINE SPECIFIC 1. 10" OR LESS NOM. DEPTH - 16d @ 12" O.C. STAGGERED DIFFUSER CEILING Z TYPE OF CURB TO USE. 2. MORE THAN 10" - (2)16d ® 12" O.C. 2. THE CONTRACTOR HAS THE OPTION OF USING THE "THERMADUCT OUTDOOR DUCT SYSTEM". 3. NO CUTTING OF TRUSS UNLESS SHOWN ON STRUCTURAL _ 3 Q W 9 ROOF DUCT SUPPORT DETAIL I ROOF FRAMING DETAIL 3 HVAC DUCTWORK DETAIL SCALE: NONE a SCALE: NONE a SCALE NONE M400 REVISIONS DESCRIPTION WE I " V HOOD INFORMATION - Job 3>08867 PATENT NUMBERS SPECIFICATION: CAPTRATE GREASE-STOP CNE30 FILTER m o EXHAUST PLENUM HOOD CONFIG. c HOOD MAX. RISERS TOTAL HOOD AC—PSP (United States) — US Potent 7963830 B2 THE CAPTRATE GREASE—STOP COMBO FILTER IS A MULTI—STAGE FILTRATION SYSTEM CONSISTING TAG MODEL LENGTH COOKING TOTAL SUPPLY END TO AC—PSP Wall Canada — CA Patent 2820509 0 u w N0. CONSTRUCTION ROW ( ) OF A HIGH PERFORMANCE S—BAFFLE COMPONENT COMBINED WITH A SECONDARY PACKED—BED FILTER w LL TEMP. EXH. CFM WIDTH LENG. HEIGHT DIA. OEM VEL. S.P. OEM END AC—PSP Island Canada — CA Patent 2520330 (Canada) OF POROUS CERAMIC MEDIA. 0 �•� �' 6630 600 20" 16" 4" 3000 1929 —1.295" 430 SS 1 12' 7" 6000 4680 ALONE ALONE FILTER ASSEMBLY SHALL FIT INTO STANDARD TWO—INCH DEEP HOOD CHANNEL(S). NDI—PSP—FB Deg. 20" 16" 4" 3000 1929 —1.295" Where Exposed 1•IN: vo8=6" METALLIC COMPONENTS STAINLESS STEEL CONSTRUCTION AND SIZED TO FIT AND DURABLE MICRO—POROUS 5430 450 430 SS CERAMIC MEDIA THAT IS CAPABLE OF ABSORBING SMALLER GREASE PARTICULATE BY MEANS OF 2 ND-2WI—PSP—SS 5' 10" Deg 2000 10" 18" 4" 2000 1600 —1.148" 1800 Where Exposed ALONE ALONE CAPILLARY ACTION. oil WE HOOD INFORMATION UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO FILTER S LIGHT S UTILITY CABINET S COMPONENTS WHEN ASSEMBLED. HOOD FIRE SYSTEM ELECTRICAL SWITCHES FIRE HOOD GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 97% OF THE TOTAL MASS I 8 N0. TAG TYPE QTY. HEIGHT LENGTH EFFICIENCY ® 7 QTY. TYPE WIRE LOCATION SIZE SYSTEM HANGING EMITTED GREASE PARTICLES AND HAVING FUNCTIONAL EFFICIENCY OF 60% GREATER OF GREASE I N MICRONS GUARD TYPE SIZE MODEL # QUANTITY PIPING WGHT II - PARTICLES EMITTED TWO MICRONS IN SIZE AND LARGER. 1 Light 156E E 1 Captrate Combo with 18 20" 16" 99% See Filter Spec. g L55 Series E26 NO Right 12"x66"x30" Ansul R102 3.0/3.0/3.0 SC-331110FP—SEP YES LBS THE CAPTRATE GREASE—STOP COMBO WAS TESTED TO ASTM STANDARD ASTM F2519-05. I " z o m m m 1 Fan El 422 m '^ 2 Captrate Combo with 4 20" 16" 99% See Filter Spec. 2 L55 Series E26 NO YES EEEICUE CY VS.PARTICLE DIAN TFER PRESSURE.DROP VS.FLOW RATE I IIIEl 8 � LBS 8 ❑ 3 w ..m J HOOD OPTIONS IIIIIII o �_ HOOD TAG OPTION I I b z 3 N0. a CC LEFT END STAN DOFF(FI N/INS— ISLAND) 1" Wide 66" Long Insulated III 2 1 STRUCTURAL FRONT PANEL 1—PINT GREASE CUP LL FINISHED BACK— ISL/REV INSTALL 70.00" Long a II N 2 1—PINT GREASE CUP OPTIONS ONLY: FIELD WRAPPER 4.00" High x 158.00" Long Front 430 Ss EXHAUST HOOD TO BE INTERCONNECTED OPTIONS ONLY: FIELD WRAPPER 4.00" High x 158.00" Long Back 430 SS C ❑ OPTIONS ONLY: FIELD WRAPPER 4.00" High x 94.00" Long Right 430 SS WITH EQUIPMENT BELOW TO RUN WHILE IN 10 3 OPTIONS ONLY: FIELD WRAPPER 4.00" High x 94.00" Long Left 430 SS a� �.o o.o o :m Sao :w •E DIAMETER cum) F1WRATE(cfm) 1 w OPTIONS ONLY: FIELD WRAPPER 4.00" High x 54.00" Long Right 430 SS OPERATION OR BE PROVIDED WITH A PARTICLE OPTIONS ONLY: FIELD WRAPPER 4.00" High x 102.00 Long Left 430 SS THERMISTOR TO ACTIVATE HOOD. NFPA #96 ,� b OPTIONS ONLY: FIELD WRAPPER 4.00" High x 102.00" Long Right 430 SS CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. OPTIONS ONLY: FIELD WRAPPER 4.00" High x 102.00" Long Left 430 SS NSF STANDARD #2 E w UL STANDARD #1046 NSF �uu d z PERFORATED SUPPLY PLENUMS . CODE (IMC)INT. MECH. «E RISERS MUA TO BE INTERCONNECTED WITH HOOD ULC-5649 I` HOOD TAG POS. LENGTH WIDTH HEIGHT TYPE NO. WIDTH LENG. DIA. OEM S.P. NMI M EXHAUST FAN MUA 12" 28" 780 0.196" U Back 164" 14" 6" MUA 12" 28" 780 0.196" 1 MUA 12" 28" 780 0.196" F MUA 12" 28" 780 0.196" d Front 164" 14" 6" MUA 12" 28" 780 0.196" v MUA 12" 28" 780 0.196" Left 54" 16 6 MUA 12" 16 450450 0.142" 1 8 MUA 12" 16 0.142 2 Right 54" 6" 6" MUA 12" 16" 450 0.142" 8 1 MUA 12" 16" 450 0.142" 27 1/4" 54 3/4" 54 3/4" o �2..� 2..� ..� ,"LAYER OF INSULATION YY FACTORY INSTALLED IN ®g ®p 1.00"END STANDOFF MEETS 0"REQUIREMENTS CLEARANCE 1q 12"—_-------- _— _—_ 12••— _—_ _ _—_ 12^—EM _� TO COMBUSTIBLE SURFACES. ® 7" 7" 7® o 5g�0�gl F�yC J J 3 � o g•' o � � a 9316 O 13 1/2' LIL 33" 33" 10' u� t79�.C OF 9FLL R•GP 8 /5/1 ANSUL R-102 WET CHEMICAL FIRE o FIRE SUPPRESSION SYSTEM 66" 20" ----- 20" ----- - FACTORY PREWIRED CONDUIT 54 27 27 LL UL.. Listed L55 Series E26 Canopy Light a 0 O Fixture— High Temp Assembly — w J o M 6" 16 16 16 W WITH FAN STARTERS AND PREWIRED ELECTRICAL PACKAGE W LL_ cli 0 W UPPLY FAN SHUT—DOWN RELAY. SEE ELECTRICAL DRAWINGS FOR DETAILS) Lf41431/2~ F U.L.Listed L55 Series E26 Canopy Light „I, W Fixture— High Temp Assembly 12" ISCREEN WITH HOOD FUNCTIONS T T T T J w F Llo g• PREWIRED BY CAPTIVE—AIRE SYSTEMS. rn 0 0 ii _J _J H Y W Cl W T16" 35" 35" 16" LL Q m Q O (nCD 14" 12"---------- ------- L 12"— ------- ------- L 12~— ------- --------_L _ J J 7 7 7 11 -0 J J J Z J 5' 10"Nom./5' 10.00"0 Z L[9 37 3/4" .�. 75 1/2' .�. 37 3/4" _ U m PLAN VIEW - Hood #2 DATE: 8/9/2017 • • • 27 1/4" � 54 3/4" � 54 3/4" - 5' 10.00" LONG 543OND-2WI-PSP-SS DWG.#: 12'7"Nam./12'zoo"OD 12" 3108867 13'-8.00'0� .11 Length DRAWN BY: AHJ-86 - SCALE: z PLAN VIEW - Hood #1 3/4" = 1'-0" - 12' 7.00" LONG 6630NDI-PSP-FB NOTE Additional hanging angles provided for hoods 12'and longer. MASTER DRAWING J9� Q SHEET NO. w � O 3 N M500 s un xs�e uV m o �C REVISIONS V w DESCRIPTION DATE: HIG C EXHAUST RISER SERIES E26 CANOPY LIGHT FIXTURE- 0 HIGH TEMP ASSEMBLY,INCLUDES CLEAR THERMAL oliIIIIIIIIIIIIIIIII � -8 L55 SERIES E26 CANOPY LIGHT FIXTURE- 54" AND SHOCK RESISTANT GLOBE(L55 FIXTURE) ,prim"' HIGH TEMP ASSEMBLY,INCLUDES CLEAR THERMAL 0 HANGING ANGLE AND SHOCK RESISTANT GLOBE(L55 FIXTURE) EXHAUST RISER Q W& 66" HANGING ANGLE i•iRi ATTACHING PLATES ATTACHING PLATES HOOD T LE SUPPLY RISER WITH SUPPLY RISER WITH N F VOLUME DAMPER VOLUME DAMPER 20"CAPTRATE COMBO a W m E HOOD TAB WITH HOOK- LP ❑ H 7 23.5%OPEN STAINLESS �- 23.5%OPEN STAINLESS STEEL PERFORATED PANEL 2 3/4" 2 3/4" STEEL PERFORATED PANEL I I ® z •u m m 6" 6" 3"INTERNAL STANDOFF I I 8 m W I I � N 30"NOM. 'I Z 4„ ® 3 w Z m 7 30"NOM. I I I I I o J a 24" 24" IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO o IT IS THE RESPONSIBILITY ENSURE THAT THE HOOD CLEARANCE I I I I I I pj OF THE ARCHITECT/OWNER TO AND CFROMOMBUS DBLE MATERIALS ENSUREb ENSURE THAT THE HOOD CLEARANCE I I I I I I FROM LIMITED-COMBUSTIBLE L IN COMPLIANCE WITH AND COMBUSTIBLE MATERIALS LOCAL CODE REQUIREMENTS. IS IN COMPLIANCE WITH W LOCAL CODE REQUIREMENTS. I 20"CAPTRATE COMBO GREASE DRAIN N WITH HOOK- LP WITH REMOVABLE CUP 44.0"MAX GREASE DRAIN WITH REMOVABLE CUP 48.0"MAX O u LL 1 € " BQ" w a 80'" = 0 O EQUIPMENT BY OTHERS EQUIPMENT :Z� rn BY OTHERS URg F v 1 e SECTION VIEW - MODEL 5430ND-2WI-PSP-SS a HOOD - #2 0 SECTION VIEW - MODEL 6630NDI-PSP-FB a HOOD - #1 5g\01NA,LL k- e a 9316 O USX O r� 099�or �9FLL R•G/5/1 W I J 0 M W CD w WLLJ Cn V I W Li- W rn W Ie W o O m¢ o vS� � 2Z L_ QL� Lo Z � N 0-) 3: DATE: 8/9/2017 DWG.#: - 3108867 z DRAW AHJ-86 SCALE: U) 3/4.. = 1'-0„ _Z MASTER DRAWING Q 3 � 0 O 0 SHEET NO. 3 O 2 M510 N xs e REVISIONS u; V DESCRIPTION DATE: _ EXHAUST FAN INFORMATION - Job 3108867FAN m C UNT TAG FAN UNIT MODEL # CFM ESP. RPM H.P. B.H.P. 0 VOLT FLA DISCHARGE WEIGHT �SONES Vy N0. VELOCITY (LBS.) �c a 1 NCA24HPFA 3000 1.750 1014 2.000 1.5740 3 208 5.9 682 FPM 246 20 2 NCA24HPFA 3000 1.750 1014 2.000 1.5740 3 208 5.9 682 FPM 246 20 3 DU180HFA 2000 1.750 1322 1.500 0.9430 3 208 4.4 462 FPM 194 18.3 oil WE MUA FAN INFORMATION - Job 3108867 I FAN EVAP COOLER EVAP COOLER EVAP COOLER EVAP COOLER DESIGN WEIGHT BURNER UNIT TAG FAN UNIT MODEL BLOWER HOUSING ESP. RPM H.P. B.H.P. 0 VOLT FLA ENTERING DB ENTERING WB LEAVING DB LEAVING WB SONES N0. # CFM TEMP. TEMP. TEMP. TEMP. (LBS.) EFFICIENCY(9) � mai 4 A4-D.1000-920 920 A4-D.1000 6480 0.750 643 3.000 2.3560 3 208 9.5 98.07 65.0'F 77.07 65.0'F 2113 19.5 92 GA FAN S FIRED MAKE-UP AIR UNITS 1 I I ® �� N INPUT OUTPUT III T 8 ❑ w i ..m_ UNIT TAG TEMP. RISE REQUIRED INPUT GAS PRESSURE GAS TYPE 26 1/2" I I I I I I ❑o z ut 3 w '2 NO. BTUs BTUs 26 1/2" I o 4 479238 440899 63 deg F 7 in. W.C. - 14 in. w.c. Natural I b a. FAN #3 DU180HFA-EXHAUST FAN VENTEFAN OPTIONS FEATURES: CURED II II w FAN UNIT TAG OPTION (Qty. - Descr.) - DIRECT DRIVE CONSTRUCTION(NO BELTS/PULLEYS) I m N0. 39 3/8 -ROOF MOUNTED FANS 22 �t 1 - Exhaust Fan Heat Baffle - RESTAURANT MODEL ,z(✓/} 'y V 1 1 - Fan Base Ceramic Seal - Installed At Plant - For Grease Ducts -UL705 STEEL GAUGE 1 - Upblast Fan Wheel Access Port -VARIABLE SPEED CONTROL STEEL - INTERNAL WIRING CONSTRUCTION Q ❑ 1 - Exhaust Fan Heat Baffle -WEATHERPROOF DISCONNECT R LL 2 1 - Fan Base Ceramic Seal - Installed At Plant - For Grease Ducts -THERMAL OVERLOAD PROTECTION(SINGLE PHASE) 1 - Upblast Fan Wheel Access Port - HIGH HEAT OPERATION 300-F(149'C) \ 3" FLANGE 1 G '' 1 - Full Crating For Exhaust Fans / 1 - Exhaust Fan Heat Baffle 33 3/4 NORMAL TEMPERATURE TEST , 3 EXHAUST FAN MUST OPERATE CONTINUOUSLY b 1 - Fan Base Ceramic Seal - Installed At Plant - For Grease Ducts 22 5/8 ROOF OPENING O ❑ WHILE EXHAUSTING AIR AT 300'F(149'C) � 1 - Upblast Fan Wheel Access Port UNTIL ALL FAN PARTS HAVE REACHED 24 DIMENSIONS Z 1 - AC Interlock Relay - 24VAC Coil THERMAL EQUILIBRIUM,AND WITHOUT ANY 24 I` 2 1 - Motorized Backd toff Damper for A4-D Housing DETERIORATING EFFECTS TO THE FAN WHICH = o WOULD CAUSE UNSAFE OPERATION. O 1 - Full Crating For Commercial Heater I 4 PITCHED CURBS ARE AVAILABLE 0" 1 - Low Fire Stort 1 - Inlet Pressure Gauge, 0-35" 2 FOR PITCHED ROOFS. U 6 1/2 0 1 - Manifold Pressure Gauge, -5 to 15"" we I I SPECIFY PITCH: 12" FAN ACCESSORIES EXAMPLE: 7/12 PITCH = 30' SLOPE ~ a FAN EXHAUST SUPPLY o 24 OPTIONS m UNIT TAG ❑ N0. GREASE GRAVITY WALL SIDE GRAVITY MOTORIZED WALL FULL CRATING FOR EXHAUST FANS 8 CUP DAMPER MOUNT DISCHARGE DAMPER DAMPER MOUNT 2�. EXHAUST FAN HEAT BAFFLE Q /\ /� FAN BASE CERAMIC SEAL- INSTALLED AT PLANT- FOR GREASE DUCTS 8 4 YES ,V/ UPBLAST FAN WHEEL ACCESS PORT ❑ CURB ASSEMBLIES DUCTWORK BEfwEEN NO, FLAN EXHAUST O OD WEIGHT ITEM SIZE AND FAN (BY OTHERS) 1 # 1 43 LBS Curb 31.500"W x 31.500"L x 22.000"H Vented 2 # 2 43 LBS Curb 31.500"W x 31.500"L x 22.000"H Vented 5\Q1\1AL�c 3 � 3 30 LBS Curb 26.500"W x 26.500"L x 22.000"H Vented 4 4 58 LBS Curb 42.000"W x 42.000"L x 20.000"H Insulated 0 # 4 Rail 6.000"W x 42.000"L x 20.000"H EL # 4 Rail 4.000"W x 4.000"L x 36.000"H N 9316 O FANS#1.#2-NCA24HPFA EXHAUST FAN 1 OF 9FLL R•G/5/1 FEATURES: \ 43 3/8 31 1/z' �I -ROOF MOUNTED FANS - RESTAURANT MODEL - UL705 AND UL762 VENTED LLl AMCA SOUND AND AIR CERTIFIED CURB 0 w 0 J -WIRING FROM MOTOR TO DISCONNECT SWITCH O -WEATHERPROOF DISCONNECT HIGH HEAT OPERATION 300'F(149'C) 22 /1 U� 00 W -GREASE CLASSIFICATION TESTING L NN> 20 GAUGE I� LLI mow// STEEL 37 1/2 NORMAL TEMPERATURE TEST CONSTRUCTION y_ W 30 5/8 EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300-F(149'C) - 0 _ cn M UNTIL ALL FAN PARTS HAVE REACHED : W THERMAL EQUILIBRIUM,AND WITHOUT ANY Y W co w J J col DETERIORATING EFFECTS TO THE FAN WHICH � � \ 3 FLANGE J WOULD CAUSE UNSAFE OPERATION. _ J- ABNORMAL FARE-UP TEST / � m¢ O J EXHAUST FAN MUST OPERATE CONTINUOUSLY ROOF OPENING =Z J WHILE EXHAUSTING BURNING GREASE VAPORS \ / DIMENSIONS ot Ln 2g w r J 2 I I AT 600'F(316'C)FOR A PERIOD OF 28 �/ (� z Z L[9 Z 15 MINUTES WITHOUT THE FAN BECOMING O� H U 23 7/8 � DAMAGED TO ANY EXTENT THAT COULD CAUSE CIO- - � AN UNSAFE CONDITION. s PITCHED CURBS ARE AVAILABLE 0 za OPTION " FOR PITCHED ROOFS. DATE: 8/9/2017 33 EXHAUST FAN HEAT BAFFLE o' FAN BASE CERAMIC SEAL-INSTALLED AT PLANT-FOR GREASE DUCTS SPECIFY PITCH: UPBLAST FAN WHEEL ACCESS PORT 12 DWG.#: I EXAMPLE: 7/12 PITCH = 30° SLOPE 310886767 DRAWN AHJ-86 DUCTWORK BETWEEN EXHAUST RISER ON HOOD 61 17 AND FAN (BY OTHERS) SCALE: 3/4" = 1'-0" MASTER DRAWING U) Z SHEET NO. q 3 0 0 w � O 3 N M520 ul REVISIONS xs�e FAN�/4 A4-D.1000-920- HEATER DESCRIPTION DATE: u. ? 1. DIRECT GAS FIRED HEATED MAKE UP AIR UNIT WITH 20"BLOWER AND 24"BURNER. m 2.EVAP COOLER(LPD CELDEK)-W/INTAKE HOOD W/EZ FILTERS 3. DOWN DISCHARGE-AIR FLOW RIGHT->LEFT 4.COOLING INTERLOCK RELAY. 24VAC COIL. 120V CONTACTS. LOCKS OUT BURNER CIRCUIT WHEN AC IS ENERGIZED. 5. MOTORIZED BACK DRAFT DAMPER 34"X 36"FOR SIZE 4 STANDARD&MODULAR HEATER UNITS W/EXTENDED SHAFT,STANDARD pp a GALVANIZED CONSTRUCTION,3/4"REAR FLANGE, NFBUP-S ACTUATOR INCLUDED SUPPLY SIDE HEATER INFORMATION: C - 6. FULL CRATING FOR COMMERCIAL HEATERS FOR SHIPPING. `IIIIIIIIIIII 7.LOW FIRE START. ALLOWS THE BURNER CIRCUIT TO ENERGIZE WHEN THE MODULATION CONTROL IS IN A LOW FIRE POSITION. WINTER TEMPERATURE= 12'F. TEMP.RISE=63'F. �a:8 A�E: oraa 8 BTUs CALCULATED OFF STANDARD AIR DENSITY .GAS PRESSURE GAUGE,0-35",2.5"DIAMETER, 1/4"THREAD SIZE OUTPUT BTUs AT ALTITUDE OF O.0 ft. =440899 9.GAS PRESSURE GAUGE, -5 TO+15 INCHES WC.,2.5"DIAMETER, 1/4"THREAD SIZE INPUT BTUs AT ALTITUDE OF 0.0 ft. =479238 W& 10 5/8" 24 7/8" I /� CURB OUTER WALL I EA \= DISCHARGE OPENING I I t•) N II E N[q F m m a i _0 � LID to m ro 17 1/2" I > m F N o1 1/2„ 28 7/8" z WATER DRAIN II i Li� 24 7/8" AIRFLOW � J a 4STE AIRFLOW I II II w L J u u u s 8 9/16" p w ?�+ o XX 4 1/2" Q LL 1 0 R a FLEX CONDUIT FOR FIELD ` w WIRING O 0 � M 225' 58 5/8" 64 3/16" 54 3/16" 35 1/4"� ~ 48 7/16" a N LIFTING LUG i 0 o AIRFLOW Q 3 AIRFLOW o SERVICE DIRECT FIRED MODULE o DISCONNECT SWITCH AIRFLOW 52 3/16" LED CELDEK FILTER/CONTROL 58 3/8" ACCESS DOOR 51 3/8" , 1/4" APT g\ONALk- BLOWER/MOTOR Q G\STEq� 2 ACCESS DOOR24 CLEARANCE SERVICE of/2" NET d 9316 o WATER INLET LLJ N 0 00 •� 13 9/16" OF\pPyki 5 1/4" 9�9FLL R•GP /5/1 zo" 14 3� 14 3/ ADJUSTABLE �LEG 0J LJ O 20"EQUIPMENT CURB 42 42"— 6" M ROOF OPENING 2"SMALLER THAN CURB DIMENSION. 00 LLJ 115 3/16 LIJ Go LJJ ' W C Direct Hred(DF)Profile Plate Assembly '\ O /^ rn w H- M oes=;ice P mono".. f— J J Y W in Lu Direct i bur a o f patented(US Patent No.:U5662952352)),self-ptlj profile J M plates designedntore na re tDroper o Ity tl Pressure d a` it e stinq thR b r.Profile W /� muwem s w b o by In9 cb e-pt ul a Q Q Cn V um of 5ppm ofe arbon monosidee(CO),entlsto.5ppm Hof nitrogn a(NO2)..t o LL Sp nq„loatletl b er profile„tares da'oendgineered to of L n 2 Z J With is�feeture.R'.II WDF unite are designednforndemand control venblabontM1(D.)frequiretmantsm ^JI Alrtrloflle plate assemblies-11 be included In Me DF unit's EfL ri.t,and comply with c tined.II DIF > U m (pfely standards ANSI Z83.4 and CSA 3.7(non-recirculating DF M1eaters)and ANSI Z83.18 0 plates"thtll be fo med fr..G90 gi,l—ized steel. hi P q 9 OTe° DATE: 8/9/2017 -Sprinq M1nges_T be made e1-plat 0.reel. DWG.#: 3108867 — DRAWN BY:AHJ-86 61 z SCALE: 3/4" = 1'-0" MASTER DRAWING U) ryo SHEET NO. q 3 0 0 4 m w � O 3 N M 530 N xs�6� ELECTRICAL PACKAGES — Job 3108867 REVISIONS SWITCHES FANS CONTROLLED DESCRIPTION DATE: N0. TAG PACKAGE III LOCATION OPTION Q b0 0 LOCATION QUANTITY OPTION b H.P.I VOLT FLA �C 04-Utility Cabinet Exhaust 3 2.000 208 5.9 V 9 1 Light Right Exhaust 3 2.000 208 5.9 Q �' 1 SC-331110FP-SEP Utility Cabinet Right Smart Controls Thermostatic Control xhaus 1. Hood 1 1 Fan ® vaS_g r Supply 3 3.000 208 9.5 p:' �oeam a or JOB NO MODEL NUMBER DRAWN BY SCHEMATA TYPE DESCRIPTION OF OPERATION: ��' LLa S C—3 31 1 1 O F P—SEP INSTALL 3 Phase w/ control for 3 Exhaust Fans, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fan(s) On/Off Thermostatically 3108867 JOB NAME DATE DWG No Controlled. Separate Breaker Input for each Fan. Room temperature sensor shipped loose for field installation. Habit — Twin Falls ID 8/9/2017 ECP #1-1 I I 8 ° 77. " E 1 I mai "I C7 Z� SON N�o mew � N F J N�J 2 FAN: 03 EXH-3 II II o 8 ❑ _LOAD_LE_G_1_______ _ _______________ _______ w z "m zi Load Wiring U1 -0% FLA:a.a ❑ 3u, BREAKER PANEL TO PRIMARY CONTROL PANEL THE FOLLOWING CONNECTIONS IIII ❑ _ __ LOAD LEG_ ______ ___ ______________ _______ HP: 1.500 Pl Yl xl�3 SM-1 V1 ----- -0% MAY OR MAY NOT BE III ❑ Responsibility: Electrician WIRE TO W1 -----LOADLgc_3----__ ______________ _______moo VOLT: 208 V REQUIRED BASED ON JOBSITE b J a 3 SPECIFICATIONS II ¢ BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED VFD QUICK ........GROUND.... _ _ _______________ _______�II IIII I BREAKER PANEL PRIMARY CONTROL PANEL CONNECTOR WIRE TO HOT TO SHUNT COIL SHUNT COIL MUST HAVE ITS OWN CONDUIT DISCONNECT CONTROL PANEL ST --------NEUT-------------HUNT-COI - �o---, 4 Hot H1 DO NOT SHARE CONDUIT! SIGNAL FOR N1 --------NEUTRAL FROM SHUNT COIL --------------------------------------- BREAKER 1 PH Neutral EXTERNAL ST TERMINAL IS ENERGIZED V ------------------------------------------------- --- FAN: 04 120 V OAD_LEG_1___________ BACK SUP-4 A:1o.7 E 5 _______ Ground_ ___� Load Wiring T1 ------ EG o HP: 3.000 SHUNT TRIP N FIRE CONDITION. O ¢ 15 A CONTROL POWER. DO NOT WIRE ST-3 T2 --_LonD LEc z_ ____ BACK O VOLT: 208 V !9 TO SHUNT TRIP BREAKER. WIRE DIRECT T3 __-LOAD LEc 3_ ____ BLACK o ______________________________COMMON_ _____ 1 0 CONTROL PANEL C2 TO STARTER GN cRouNo_ ____ GREEN NORMALLY OPEN 8 6 1ST HOOD LIGHT BREAKER SHARED W/ CONTROL SPARE FIRE AR2 ---------------------------------------- ----- v POWER. SWITCH #1 WIRE TO FACTORY SPARE CONTACTS WILL MAKE C2 TO , v PROVIDED CONDUIT DROP SYSTEM DRY AR2 WHEN SYSTEM IS ARMED. THEY o _--__LINE_ --_ L1 ARE USED TO DISABLE EQUIPMENT --------------------------------------- CONTACT w BREAKER 3PH OR PROVIDE SIGNALS. (NOT FOR is s o 7 ____________________________________________LINE_ 208 V L2 BUILDING FIRE ALARM WHICH MUST +' is LINE BE WIRED DIRECTL TO THE ANSUL 0 MCA: 7.4 A --------------------------------------------- L3 ALARM INITIATING SWITCH LOCATED ` M __________________________________________Ground_ IN ANSUL AUTOMAN) I MOCP:15 A 8 EXH1 CONTROL PANEL TO ACCESSORY ITEMS eMs SWITCH CONTROL PANEL H1 ---------------------------------------- - -�o%N°, ____________________________________________LINE_ L4 Responsibility: Electrician To 01 9 BREAKER 3PH ---------------------------------------------LIINE_ _-- L5 CONTROL PANEL COMPONENT EXTERNAL SIGNAL SWITCH THROUGH BMS 208 V LINE WILL ACTIVATE ZONE1 FANS AND o MCA: 7.4 A ---- ---- ---- ---- ---- - --- L6 SWITCH LIGHTS 1 ❑ _____ _____ _____ _____ ___Ground_ --_� MICROSWITCH 1 8 10 MOCP:15 A EXH-2 CONTROL PANEL 4:NOCAF 3 TO C 1 1_�2:_NC o ---------------------------------------- 11 LINE FIRE SYSTEM BREAKER 3PH ------------------------------------------------- --- L7 AR1 WIRE C1 TO LINE COMMON-���------------ MICROSWITCH 208 V --------------------------------------------LINE L8 WIRE ART TO NORMALLY CLOSED (2).----------------------------------------------- -- --- L9 C1 TO ART SHOULD HAVE MS-1 GAP MCA: 5.5 A 4'NOOFF 12 _ ________________________________________Ground_ _ CONTINUITY WHEN ARMED. t �OI\AL MOCP: 15 A EXH-3 SM-1 ^� WIRE TO VFD QUICK CONNECTOR F MORE THAN ONE r------------------- 0 FIRE SYSTEM, WIRE MS-2 4:NOOFF a 13 LI NE IN SERIES AS SHOWN L__--1_C 2:NC � 9316 9 BREAKER 3PH LINE 14 208 V LINE OF ----------------------------------------------- C, - --- L 2 U) 9 9 \O�w MCA:13.0 A - - ----------------------------------Ground_ _ � FLL R• MOCP:20 A SUP-4 /5/1 CONTROL PANEL a ALL SWITCHES FACTORY WIRED 15 TO CAT-5 CONNECTION SWITCHES LLL J � I" o DO ch 16 HOOD LIGHTS 1 _ � � w CONTROL PANEL B --------------------------------BLACK - _ CONTROL PANEL TO FANS --- Lu LU WHITE ______ L W 17 Responsibility: Electrician TO W1 Lu _ I�1- -------------' D w HOOD LIGHTS N - - - - - ---------------GREEN-- -- C PRIMARY PANEL FANS 400 W MAX WIRE TO J—BOX ON TOP OF HOOD O0 w 22 � H 18 J J H Y w o W FAN: 01 EXH-1 Load Wiring T1 -----LOAD_LEG_1_________________________ _______moo FLA:5.9 CONTROL PANEL T1A - J --------------------------------------- ------- LL_ Q ¢ O � ST—1 T2 -----L°A- LEG-2------------------------- -------- HP: : 200 To T1 B ---------------------------------------- - _ VOLT: zoa v WIRE TO CONTROL BOARD. -� 19 WIRE DIRECT T3 _____LOAD LEG_3_________________________ _______do KITCHEN TEMP ROOM TEMP 2 z SENSOR MOUNTED IN ROOM AWAY � N Z LLB z � z J TO STARTER (�J ........GROUND_________________________ SENSOR FROM HEAT SOURCES. SEE MANUAL = N U LO m WIRE TO 20 DISCONNECT CONTROL PANEL T2A TO FAN: 02 EXH-2 T2B FACTORY WIRED TEMPERATURE HOOD 1 DATE: 8/9/2017 SENSOR. MOUNTED IN EXHAUST DUCT RISER 1 DWG.#: __LOAD_LE_G_1_________________________ _ DUCT SENSOR Load Wiring T1 --- ------moo FLA:5.9 21 ST-2 T2 _____LOAD LEG_3---------------------------------- /p HP: 2.000 T3 VOLT: 208 V 3108867 WIRE DIRECT _____LOAD LEG_3_________________________ _______-0/a CONTROL PANEL T3A DRAWN — _______ Blf.AHJ-86 o g TO STARTER (jN ________GROUND_________________________ 11, TO T3B o N U 22 FACTORY WIRED TEMPERATURE HOOD 1 WIRE TO DUCT SENSOR DISCONNECT SENSOR. MOUNTED IN EXHAUST DUCT RISER 2 SCALE: 23 CONTROL PANEL T4A --------------------------------------- -------- -� MASTER DRAWING r, U) woo TO T4B -WIRE TO CONTROL BOARD. HOOD 2� 24 DUCT SENSOR SENSOR MOUNTED IN EXHAUST DUCT RISER 1 m Q ry SHEET NO. q 3 0 0 5 m w l> O 3 N 0 M540 PLUMBING SPECIFICATIONS 2. BACKFILLING: PERFORM ALL NECESSARY EXCAVATING AND BACKFILLING REQUIRED FOR THIS INSTALLATION. PREPARE A GENERAL PROPER BED OF SAND OR GRAVEL OR EQUIVALENT IN ROCK SCREENINGS SO AS TO ELIMINATE SHIMMING PLUMBING FIXTURE SCHEDULE Es6e A. THE GENERAL CONDITIONS OF THE GENERAL SPECIFICATIONS, ALONG WITH ALL APPLICABLE AND VOID SPACES UNDER ANY OF THE UTILITY SERVICE PIPES. BENDING OF ANY HARD PIPE WILL NOT BE INSTRUCTIONS TO BIDDERS SHALL FORM A PART OF THIS SECTION OF THE SPECIFICATIONS. PERMITTED. WHERE A CHANGE IN DIRECTION IS NECESSARY ON PRESSURE PIPES, "COMPATIBLE" ;; u COUPLINGS OR EQUAL SHALL BE USED AND BENDS MAY NOT EXCEED 90 DEGREES. ALL EXCAVATION FIXTURE DATA CONNECTION DATA _ B. REFERENCE IS MADE TO REQUISITES FOR BIDDERS AND CONTRACTORS UNDER OTHER BELOW THE BOTTOM OF FOOTINGS SHALL BE BACKFILLED WITH 2O00 PSI CONCRETE. OTHER BACKFILL pp o SECTIONS OF THESE SPECIFICATIONS, WHICH SHALL BE CONSIDERED BINDING, UNLESS SHALL CONSIST OF 2-3" OF SAND OR ROCK SCREENINGS AND EARTH TO A FINAL LEVEL EQUAL TO ITS DESCRIPTION �5 i OTHERWISE NOTED UNDER THIS SECTION. ORIGINAL CONDITION. IN THE EVENT THE BACKFILL SHOULD SETTLE BEFORE THE FINAL TOP SURFACE IS PLAN PROVIDED SOIL VENT INDIRECT WATER y APPLIED, APPLY ADDITIONAL BACKFILL TO SUSTAIN THE ORIGINAL LEVEL. CARE SHOULD BE TAKEN TO TAG FIXTURE QTY. MFG. BY SIZE SIZE TRAP WASTE SCOPE MINIMIZE THE DUST LEVEL WHEN EXCAVATING AND BACKFILLING SO AS TO COMPLY WITH FEDERAL AND COLD HOT TW FILTER �•c EACH CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE CONSTRUCTION DETAILS BOTH STATE E.P.A. REGULATIONS RELATING TO THIS TYPE OF WORK (FUGITIVE DUST). ADA COMPLIANT, ELONGATED BOWL, VITEROUS CHINA, L28 GPF, HIS ON TENANT CONSTRUCTION DRAWINGS AND LANDLORD'S AS REFERRED RTo,'S BEFORE SUBMITTING AMERICAN ogNo HIS BID AS NO ALLOWANCES WILL BE MADE BECAUSE OF THE CONTRACTOR'S UNFAMILIARITY WITH 3. PIPING INSTALLATION: WATER CLOSET GENERAL __ SEAT: BEAM IS #1955C OPEN FRONT, WHITE. TRIP LEVER TO BE �^—`� WC-1 STANDARD 4" 2' INTEGRAL ----- 1' --- --- - � '° � HANDICAPPED CONTRACTOR ON THE WIDE SIDE OF STALL SLOAN ROYAL WES-111 DUAL °My THESE DETAILS. ALL PERFORMANCE OF CONSTRUCTION SHALL BE AS REQUIRED BY THE PACE OF CLEAN-OUTS MUST BE INSTALLED GS MINIMUM DROP LINES EVEN THOUGH NOT SHOWN ON THE 2857.128 FLUSH THE GENERAL CONSTRUCTION. BLUEPRINTS. USE REDUCING FITTINGS IN MAKING REDUCTIONS IN SIZE OF PIPE. REAM ALL PIPE AFTER CUTTING, THEN TURN PIPES ON END AND KNOCK OUT ALL LOOSE DIRT AND SCALE BEFORE INSTALLING. AMERICAN 4" CENTERS WALL MOUNTED, CHICAGO 333-E2805-665PSHAB INSPECTION OF SITE MAKE CHANGES IN HORIZONTAL DIRECTION OF SOIL AND WASTE PIPES WITH LONG RADIUS FITTINGS OR GENERAL _____ ___ ___ ALL PROPOSALS SHALL PRECLUDE THAT CONTRACTOR IS FAMILIAR WITH JOB SITE CONDITIONS AND WITH "Y" BRANCHES AND 1/8 OR 1/16 BENDS. CONNECT SOIL STACKS AT BASE TO HORIZONTAL RUNS LAV LAVATORY STANDARD CONTRACTOR 1-1/2 1-1/2 1-1/2 1/2 1/2 FAUCET. .5 GPM. UTILITY LOCATIONS AND THE LACK OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE WITH 'Y" CONNECTIONS. 0356.421 THE CONTRACTOR OF ANY RESPONSIBILITY. IN I I I IE WATER SUPPLY PIPES TO FIXTURES AND WASTE PIPES FROM FIXTURES SHALL BE CENTERED IN THE AMERICAN ADA COMPLIANT, VITREOUS CHINA, LOW CONSUMPTION (0.125 PERMITS PROPER PLACE RELATIVE TO THE CENTER LINE OF THE FIXTURE. NO OFFSETS WILL BE ALLOWED. ALL GENERAL _____ ___ ___ ___ GEE), SIPHON JET ACTION, 3/4" INLET SPUD, 2" OUTLET. SLOAN ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE PIPES SHALL BE RUN MECHANICALLY STRAIGHT AND SQUARE WITH BUILDING LINES, EXCEPT FOR REQUIRED UP URINAL STANDARD CONTRACTOR 2 1 1/2 2 3/4 ROYAL FLUSHOMETER MODEL 186-0.125 HIGH EFFICIENCY 6590.503 SECURED AND PAID FOR BY THE SUBCONTRACTOR INVOLVED. PITCH ON HORIZONTAL LINES, AND ALL CHANGES IN DIRECTION SHALL BE MADE WITH FITTINGS. WATER MANUAL FLUSH VALVE, .125 OFF PIPING TO BE ROUTED IN WALLS, UNDER THE FLOOR SLAB, AND ABOVE SUSPENDED CEILINGS AS NOTED. F, N CODE REQUIREMENTS WHERE WATER LINES ARE ROUTED UNDER THE FLOOR SLAB, NO MECHANICAL JOINTS SHALL BE MADE J.R. SMITH GENERAL WITH BRONZE STRAINER, DOUBLE DRAINAGE FLANGE, WEEP ^m ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS, UNDER THE SLAB EXCEPT AS LISTED BELOW. WATER PIPING SHALL BE INSTALLED NOT TO EXERT VERTICAL FD FLOOR DRAIN 3" 1 1/2" 3" ~ „m z DRAWINGS OR AS DIRECTED BY THE OWNER, AND SHALL SATISFY ALL APPLICABLE CODES, 2005 SERIES CONTRACTOR HOLES AND TRAP PRIMER NOR HORIZONTAL STRESSES ON THE SEATING OF UNIONS. UNIONS SHALL BE COPPER TYPE NIBCO # 733 i ORDINANCES, OR REGULATIONS OF THE GOVERNING BODIES, WHETHER 50 SHOWN OR NOT, AND ALL OR EQUAL. PROVIDE AIR CHAMBER TYPE WATER HAMMER ARRESTORS OR ACCEPTABLE FACTORY -- CAST IRON BODY WITH WHITE PORCELAIN COATED INTERIOR, WITH MODIFICATIONS REQUIRED BY SUCH AUTHORITIES SHALL BE MADE BY THE CONTRACTOR WITHOUT ANY MANUFACTURED SUBSTITUTES AT ALL WATER ROUGH-IN LOCATIONS. FS-1 FLOOR SINK WATTS GENERAL 3" 1 1 2" 3" ----- --- --- - - ALUMINUM DOME BOTTOM STRAINER AND LOOSE SET PORCELAIN N a 3 ADDITIONAL COST TO THE OWNER. FS-740 CONTRACTOR / ENAMEL COATED CAST IRON HALF GRATE. HOLD CENTER LINE OF MATERIALS AND WORKMANSHIP NO WAX, PUTTY, OR VARNISH WILL BE PERMITTED. CRACKED FITTINGS SHALL BE REMOVED AND REPLACED FLOOR SINK 14" FROM WALL. A. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS WITH NEW FITTINGS. MAKE THREADED JOINTS IN BRASS PIPE AND FITTINGS WITH PIPE THREADING TO THE SHOULDER THE FITTINGS. NO SLIP JOINTS OR COUPLING JOINTS IN BRASS PIPE WILL BE PERMITTED, PRECISION MODEL #PRSOOAUS, ALL BRONZE TRAP PRIMER WITH REMOVABLE RECOMMENDED BY THE MANUFACTURERS, AND UNLESS OTHERWISE SPECIFIED SHALL BE EXCEPT ON THE FIXTURE SIDE OF THE TRAP. TRAP GENERAL ___ ___ ___ _____ ___ ___ NEW, AND FREE FROM ANY DEFECTS. ALL LIKE MATERIALS USED SHALL BE OF THE SAME TP PRIMER PLUMBING CONTRACTOR 1/2 --- OPERATING PARTS, INTEGRAL MANUFACTURE AND QUALITY UNLESS OTHERWISE SPECIFIED. 4. NATURAL GAS PIPING: PRODUCTS VACUUM BREAKER GASKETED ACCESS COVER AND CHROME PLATED. FOR ABOVEGROUND INSTALLATIONS, ALL FITTINGS TO BE JOINED WITH TEFLON TAPE SEAL OR OTHER THERMOSTATIC WATER MIXING VALVE MODEL LFe480, INTEGRAL B. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY COMPETENT WORKMEN AND SUITABLE SEAL AND MADE IN CONFORMANCE WITH THE BEST PRACTICES OF AGA AND NFPA 54. UNIONS COMBINATION CHECK STOPS WITH STRAINERS, TEMPERATURE EXECUTED IN A NEAT AND WORKMANLIKE MANNER. WORK SHALL BE PROPERLY PROTECTED SHALL BE CAST BLACK IRON AND INSTALLED IN A MANNER SUCH THAT NO STRESS WILL BE PLACED ON THERMOSTATIC GENERAL ___ ___ ___ _____ 1/2" 1/2" 1/2" ___ RANGE: 80 TO 140 DEG., FLOW CAPACITY OF A MINIMUM OF .5 DURING CONSTRUCTION, AND ON COMPLETION, THE INSTALLATION SHALL BE THOROUGHLY THE MALE-FEMALE SEALING SURFACES. PROPER ALIGNMENT WILL BE MADE AT TIME OF INSTALLATION. ALL TMV-1 MIXING VALVE POWERS CONTRACTOR IN IN OUT GPM TO MAX 12 GPM, BRONZE BODY, INTEGRAL FILTER WASH, CLEANED AND ALL DEBRIS PRESENT AS A RESULT OF THIS CONTRACT SHALL BE REMOVED JOINTS AND CONNECTIONS SHALL BE THOROUGHLY CLEANED OF OIL, THREAD CUTTINGS AND RESIDUALS CHECK VALVES, ADJUSTMENT CAP WITH LOCKING FEATURE, 0.5 FROM THE PREMISES, DO NOT JUST ABANDON. TO ACCEPT ENAMEL PAINT. ROUGH OR SHARP EXPOSED THREAD SURFACES SHALL BE FILED SMOOTH. GPM MINIMUM FLOW. ASSE 1070 APPROVED. CODES AND REGULATIONS S. WATER PIPE: CAST IRON CAULKING FERRULE WITH BRASS RAISED HEAD PLUS JOINTS SHALL BE CLEANED AND DEBURRED AS RECOMMENDED BY THE MANUFACTURER AND FEDERAL, WALL J.R. SMITH GENERAL EACH SUBCONTRACTOR SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES AND REGULATIONS WOO VARIES --- --- ----- --- --- --- --- POLISHED NICKEL ALLOY OR STAINLESS STEEL COVER PLATE. BEARING ON THE CONDUCT OF THE WORK AS DRAWN RE SPECIFIED. IF A SUBCONTRACTOR CLEANOUT 4420 SERIES CONTRACTOR SECURE WITH SCEW SPIGOT CONNECTION. STATE, AND LOCAL CODES AND SOLDERED AS LISTED BELOW. FLUX SHALL BE NON-CORROSIVE. OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT A VARIANCE, HE SHALL PROMPTLY NOTIFY THE GENERAL CONTRACTOR AND THE TENANT IN WRITING. IF ANY SUBCONTRACTOR ABOVE GRADE - WHERE FITTINGS ARE SOLDERED BOTH FITTINGS AND TUBING SHALL BE CLEANED AS FLOOR J.R. SMITH GENERAL LEVELEZE COATED CAST IRON BODY WITH ADJUSTABLE HOUSING, PERFORMS ANY WORK KNOWING IT TO BE CONTRARY TO LAWS, ORDINANCES, RULES AND DESCRIBED ABOVE. UNDER NO CIRCUMSTANCES SHALL DISSIMILAR METALS COME INTO DIRECT CONTACT FCO 4' --- --- ----- --- --- --- --- REGULATIONS AND WITHOUT GIVING SUCH NOTICE, THE SUBCONTRACTOR SHALL BEAR ALL COSTS CLEANOUT 4020 SERIES CONTRACTOR SATIN NICKEL ALLOY TOP AND INSIDE CAULK CONNECTION. WITH COPPER TUBING; E.G., GALVANIZED STRAPPING, HANGERS, OR CLAMPS TO SECURE THE TUBING. ARISING THEREFROM. BELOW GRADE, OR FLOOR SLAB ON EARTH OR STONE FILL - HIGH TEMPERATURE, SOLDER, 1200 DEG. F OWNER GAS WATER HEATER, MODEL BTH-120, 120,000 BTH, 60 GALLON, PROTECTION OF WORK AND PROPERTY OR GREATER MELTING POINT. WATER FURNISHED ___ ___ ___ ____ ___ ___ 173 GPH RECOVERY U 80 DEG. TEMP RISE, SET OUTLET WATER A. EACH SUBCONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF ALL HIS WH HEATER A. 0. SMITH CONTRACTOR - 1 1/2 1 1/2 TEMPERATURE AT 125' F.. PIPE T&P FULL SIZE TO NEAREST DRAIN. WORK FROM DAMAGE AND SHALL PROTECT THE OWNER'S PROPERTY FROM INJURY OR NOTE: WATER PIPE TO BE PROPERLY SECURED AND ALIGNED SO AS NOT TO EXERT VERTICAL OR INSTALLED PROVIDE A. 0. SMITH EXPANSION TANK, MODEL ST-25-V. LOSS ARISING FROM HIS WORK. HE SHALL MAKE GOOD ANY SUCH DAMAGE, INJURY, OR HORIZONTAL STRESSES ON THE SEATING OF THE MATING (MALE AND FEMALE) SURFACES OF THE LOSS, EXCEPT SUCH AS MAY BE DIRECTLY DUE TO CAUSES BEYOND HIS CONTROL AND UNIONS. OWNER GRUNDFOS MODEL UP-15-29-SF-T, SET PUMP TO PROVIDE A NOT TO HIS FAULT OR NEGLIGENCE. HE SHALL ADEQUATELY PROTECT ADJACENT RECIRCULATION FURNISHED ___ ___ ___ _____ MAXIMUM OF 2 GPM THRU THE SYSTEM AT 10 FT. HEAD PLUS PROPERTY AS WELL. A. MATERIALS - UNDERGROUND: TYPE "L" COPPER TUBE, SOFT TEMPER CRT PUMP GRUNDFOS CONTRACTOR 1/2 ___ ___ ___ PIPING LOSSES, INTEGRATED TIMER; 115V, .022 AMPS, 25 WATTS, B. EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS FOR THE SAFETY OF B. MATERIALS - ABOVEGROUND: TYPE "L" COPPER TUBE, HARD DRAWN. INSTALLED 1/25 HP. THEIR EMPLOYEES ON THE WORK AND SHALL COMPLY WITH ALL PROVISIONS OF FEDERAL, BACKFLOW _- MODEL 009, BRONZE BODY CONSTRUCTION, QUARTER TURN BALL STATE AND LOCAL BUILDING CODES AND SAFETY LAWS TO PREVENT ACCIDENTS OR INJURY PREVENTER GENERAL ___ ___ ___ _____ ___ ___ TO PERSONS ON OR ADJACENT TO THE PREMISES WHERE THE WORK IS BEING C. INSULATION: INSULATION FOR COLD WATER PIPING SHALL K OR INSULATION FOR HOT WATER BFPI SODA MACHINE WATTS CONTRACTOR 1/2 - VALVES. CERTIFIED TEST PREFORMED BEFORE TURN OVER TO HABIT PERFORMED. EACH SUBCONTRACTOR SHALL MAINTAIN ALL INSURANCE REQUIRED TO AND HOT WATER RE-CIRCULATION SHALL BE 1 1/2"THICK FOR PIPE SIZES 1"TO 2"AND 1' THICK / CARBONATOR BURGER. PROTECT HIMSELF, OWNER AND TENANT FOR THE DURATION OF THE WORK AGAINST FOR PIPE SIZES 3/4"AND SMALLER. INSULATION SHALL BE ARMSTRONG ARMAFLEX UL LABELED OR PROPERTY DAMAGE AND PUBLIC LIABILITY. FIBERGLASS 25 WITH ASJ/SSL FOIL/VINYL JACKET OR EQUAL HAVING A CONDUCTIVITY RANGE OF BACKFLOW SD-2, DUAL CHECK BACKFLOW PREVENTER, 316 STAINLESS STEEL CHANGES IN THE WORK CONTRACTOR 0.22-0.25. INSULATE ALL PIPING AND FITTINGS. BFP2 PREVENTER WATTS GENERAL ___ ___ ___ _____ 1/2" --- ___ --- BODY ASSE 1032 APPROVED, CERTIFIED TO ANSI/NSF STANDARD 18. THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK OR MAKE CHANGES BY 6. GAS PIPING TEA BREWER CERTIFIED TEST PREFORMED BEFORE TURN OVER TO HABIT BURGER. ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED A. UNDERGROUND GAS PIPING: ASTM A53, SCHEDULE 40 BLACK STEEL PIPE WITH LONG RADIUS STEEL ACCORDINGLY. WELDING FITTINGS INCLUDING CATHODIC PROTECTION OR POLYETHYLENE AS APPROVED BY LOCAL GAS BUILDING GENERAL COMPANY AND AUTHORITY HAVING JURISDICTION. RPBFP BACKFL ___ ___ ___ ____OW EXISTING CONTRACTOR - 1-1/2 ___ ___ --- EXISTING. SEE CIVIL DRAWINGS. COOPERATION PREVENTER ALL WORK UNDER THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN CONJUNCTION WITH OTHER B. GAS PIPING ABOVE GROUND: ASTM A53, SCHEDULE 40 BLACK STEEL WITH 125 POUND BLACK CONTRACTORS AND TRADES OF THIS PROJECT IN A MANNER WHICH WILL ALLOW EACH CONTRACTOR MALLEABLE IRON SCREWED FITTINGS. INSTALL MOISTURE TRAPS ON HVAC UNITS, WATER HEATER, AND AND TRADE ADEQUATE TIME AT THE PROPER STAGE OF CONSTRUCTION TO FULFILL HIS CONTRACTS. KITCHEN EQUIPMENT. JOSAM REFERENCE SHALL BE MADE TO THE OWNER FOR INSTRUCTIONS SHOULD ANY QUESTIONS ARISE C. GAS PIPING COMPOUND AT JOINTS; IN COMPLIANCE WITH NFPA BULLETIN #54 AND LOCAL FS_2 FLOOR SERIES GENERAL 3" 1 1/2" 3" _____ ___ ___ ___ ___ 8X8X6 WITH 3/4 GRATE. rj\OPAL Ej� BETWEEN TRADES AS TO THE PLACING OF LINES, DUCTS, CONDUITS, FIXTURES, OR EQUIPMENT, OR APPLICABLE CODES AND SUITABLE FOR NATURAL GAS SERVICE. DRAIN 49300-LF-4 CONTRACTOR SHOULD IT APPEAR DESIRABLE TO REMOVE ANY GENERAL CONSTRUCTION WHICH WOULD AFFECT THE APPEARANCE OR STRENGTH OF THE STRUCTURE. 7. WASTE PIPING: a INSTALL HORIZONTAL DRAIN AND WASTE PIPES WITH 1/4"/FT. SLOPE. SUBSTITUTION OF MATERIALS 9316 MANUFACTURER'S NAMES ARE LISTED HEREIN TO ESTABLISH A STANDARD. THE PRODUCTS OF OTHER MATERIALS: Nj O MANUFACTURERS WILL BE ACCEPTABLE, IF IN THE OPINION OF THE OWNER OR OWNERS SOIL, WASTE AND VENT PIPING SHALL BE PVC SCH. 40 PIPING FOR SANITARY WASTE IN LIEU OF EQUIPMENT LIST p,9�9lFOF�pPyk� REPRESENTATIVE THRU A SUBMITTAL PROCESS, THE SUBSTITUTE MATERIAL IS OF A QUALITY AS GOOD CAST IRON WHERE ALLOWED BY AUTHORITY HAVING JURISDICTION. PIPING SHALL NOT BE EXPOSED IN OR BETTER THAN THE MATERIAL SPECIFIED, AND WILL SERVE WITH EQUAL EFFICIENCY AND PLENUMS OR THE OPEN CEILING AREA IN THE DINING ROOM, CAST IRON - HUB TYPE WITH 9ELLR•�' DEPENDABILITY, THE PURPOSE FOR WHICH THE ITEMS SPECIFIED WERE INTENDED. NEOPRENE JOINTS - WITH STAINLESS STEEL CONNECTORS WHEN PVC IS NOT ALLOWED PER LOCAL /5/1 CODE. ALTERNATE BID ITEM CAST IRON NO HUB AND FITTINGS, WRAPPED WITH 3 MIL. PLASTIC, OR SHOP DRAWINGS A.B.S. PIPING, BELOW SLAB OR GRADE ONLY, IF APPROVED BY LOCAL ADMINISTRATIVE AUTHORITY. SHOP DRAWINGS AND CATALOG DATA ON ALL MAJOR ITEMS OF EQUIPMENT AND SYSTEMS, AND SUCH INDIRECT WASTE PIPING TO BE IN COOLER/FREEZER, 3 COMPARTMENT SINK AND PREP SINK TO BE Of- > OTHER ILLUSTRATIVE MATERIAL AS MAY BE CONSIDERED NECESSARY BY THE TENANT, SHALL BE COPPER LINES FOR INDIRECT CONNECTION TO FLOOR SINK, CONDENSATE PIPING TO BE PVC. W m SUBMITTED BY THIS CONTRACTOR IN ADEQUATE TIME TO PREVENT DELAY AND CHANGES DURING m p CONSTRUCTION. 8. PIPE SLEEVES/ESCUTCHEONS: F- c J DRAWINGS AND SPECIFICATIONS PROVIDE CHROME-PLATED ESCUTCHEONS ON ALL PIPES PASSING THROUGH WALLS, FLOORS, OR CEILINGS z A. T HE DRAWINGS SHOW DIAGRAMMATICALLY THE LOCATIONS OF THE VARIOUS LINES, DUCTS, Z o OF FINISHED ROOMS. ESCUTCHEONS TO BE BEATON & CADWELL, #10, 40, 6A OR EQUIVALENT WITH Q SET-SCREWS. PROVIDE ESCUTCHEONS ON ALL WASTE LINES FROM PLUMBING FIXTURES, WHETHER W p O Of M CONDUITS, FIXTURES, AND EQUIPMENT AND THE METHOD OF CONNECTING AND THROUGH WALLS, FLOORS, AND WHETHER CONCEALED BEHIND COUNTERS OR EXPOSED. PIPE SLEEVES E DESCRIPTION OF OL MANUFACTURER MODEL NUMBER w CONTROLLING THEM. IT IS NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL AND SHALL BE PROVIDED WHEN PIPES PENETRATE FOUNDATION AND SHALL BE 1" LARGER THAN PIPE, SEAL ALL FITTINGS REQUIRED FOR A COMPLETE SYSTEM. SLEEVE W/CAULKING. 6 JANITOR'S SINK 1 GC W CIO B. SHOULD ANY CHANGES BE DEEMED NECESSARY BY THE CONTRACTOR IN ITEMS SHOWN ON 9. PLUMBING FIXTURES: 6.5 HOSE BIBB 1 GC Ly CONTRACT DRAWINGS, THE SHOP DRAWINGS, DESCRIPTIONS,AND THE REASON FOR THEFURNISH AND INSTALL PLUMBING FIXTURES AS SHOWN ON DRAWINGS WITH ALL ACCESSORIES AND TRIM 7 GREASE INTERCEPTOR 1 LL PROPOSED CHANGES SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. fn Q' o AS LISTED. ALL FIXTURES SHALL BE PROTECTED THROUGH THE COURSE OF THE CONSTRUCTION. ANY LlJ F M � RESPONSIBILITY FIXTURE DAMAGED SHALL BE REPLACED WITHOUT ADDITIONAL EXPENSE TO THE OWNER. 9 WATER HEATER 1 OSV AO.SMITH BTH120 w 00 A. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE SATISFACTORY AND COMPLETE 10. CONNECTION TO OTHER FIXTURES: 10 WATER FILTER ASSEMBLY 1 KEC EVERPURE EV9329-73 ~Y OJ p Lu EXECUTION E ALL WORK INCLUDED IN HIS CONTRACT. HE SHALL PRODUCE COMPLETE CONNECT BUILDING SERVICE PIPING, INCLUDING BUT NOT LIMITED TO WATER, DRAIN, AND GAS PIPES TO m O FINISHED OPERATING SYSTEMS AND PROVIDE ALL INCIDENTAL ITEMS REQUIRED O PART OF FOOD SERVICE EQUIPMENT AS INDICATED IN EQUIPMENT SPECIFICATIONS. PROVIDE BACKFLOW PROTECTION 11 BAGIN-BOX RACK 1 OSV Q HIS WORK, REGARDLESS OF WHETHER SUCH ITEM IS PARTICULARLY SPECIFIED OR INDICATED ON ICE MACHINES AND BEVERAGE EQUIPMENT SUPPLY CONNECTIONS. Z J J . 11, TESTS: 12 CARBONATOR 1 OSV GENERAL PROVISIONS A. DRAINAGE AND VENT PIPING - DRAINAGE AND VENT PIPING SHALL BE TESTED BEFORE THE PLUMBING Z � Z 1. SCOPE: PROVIDE ALL LABOR, MATERIAL, AND EQUIPMENT N ACCORDANCE WITH THESE 13 PREP-TABLE WITH SINK 1 KEC CUSTOM FABRICATION CUSTOM SPECIFICATIONS AND THE ACCOMPANYING DRAWINGS TO PROVIDE A COMPLETE AND PROPERLY FIXTURES ARE INSTALLED BY CAPPING THE OPENINGS AND FILLING THE ENTIRE SYSTEM WITH WATER U — m OPERATING PLUMBING SYSTEM FOR THE BUILDING. AND ALLOWING IT TO STAND THUS FILLED NOT LESS THAN ONE (1) HOUR. INSPECT WATER LEVEL 14 3-COMPARTMENT SINK 1 KEC CUSTOM FABRICATION CUSTOM TO DETERMINE IF PIPING IS TIGHT. OBTAIN WATER, SEWER, GAS TAPS, AND ANY OTHER REQUIRED UTILITIES AND EXTEND SERVICE B. WATER PIPING - THE WATER SUPPLY PIPING LINES SHALL BE TESTED BEFORE THE PLUMBING 15 HEAT SOAK TANK 1 KEC HYGINEX 40 GAL.CAPACITY FROM SAME TO BUILDING AS SHOWN ON DRAWINGS. VISIT THE SITE FOR UNDERSTANDING OF FIXTURES ARE CONNECTED BY FILLING THE ENTIRE SYSTEM WITH POTABLE WATER AND APPLYING THE WORK TO BE DONE BEFORE SUBMITTING BID. HYDROSTATIC PRESSURE OF 100 PSI AND ALLOWING TO STAND FOR NOT LESS THAN FOUR (4) 16 ICE MACHINE 1 KEC MANITOWOC IY-0504A(SELF CONTAINED) W HOURS AT THIS PRESSURE TO PROVE PLUMBING INTEGRITY. 17 ICE BIN 1 KEC MANITOWOC F-700 W COORDINATE THIS WORK WITH THE WORK OF THE OTHER TRADES ON THE PROJECT. ALL C. GAS PIPING - IN LIEU OF LOCAL REQUIREMENTS, GAS PIPING SHALL BE FILLED WITH COMPRESSED J PLUMBING IS TO BE ROUGHED IN WHILE THE BUILDING IS BEING CONSTRUCTED AT SUCH TIMES AIR TO 150 PSI AND HELD FOR A PERIOD OF FOUR (4) HOURS. EACH JOINT SHALL BE CHECKED - AS NOT TO DELAY THE GENERAL CONTRACTOR ON THE BUILDING. BY LIQUID SOAP OR SPECIAL LIQUID CHEMICAL FOR LEAKS. NOTE: REMOVE ALL GAS VALVES AND 23 FRYER BATTERY 1 KEC PITCO FRIALATOR 3-SSH55SSTC-S/FD Q PROTECT FROM DAMAGE BEFORE TESTING SYSTEM. 24 CHARBROILER 1 KEC MAGIKITCHEN CM-SMB-636 2. GENERAL REQUIREMENTS: COMPLY WITH ALL FEDERAL, STATE,AND LOCAL REQUIREMENTS, - W CODES, RULES, AND ORDINANCES GOVERNING WORK OF THIS CHARACTER. PAY FOR AND 12. DISINFECTION OF POTABLE WATER SYSTEM: 27 COUNTER TOP GRIDDLE 48" 1 KEC VULCAN CG58-HBT1 2 s OBTAIN NECESSARY CONSTRUCTION PERMITS AND CERTIFICATES OF INSPECTION. WHERE REQUIRED BY LOCAL JURISDICTION, ALL SYSTEMS SHALL BE INITIALLY FLUSHED TO PURGE 27.1 COUNTER TOP GRIDDLE 36" 1 KEC VULCAN CG58-HBT1 �Z U DELETERIOUS MATTER AND CONTINUE UNTIL POTABLE WATER APPEARS AT POINTS OF OUTLETS. UPON S/S COUNTER WITH HAND SINK WITH - Cn A. DRAWINGS: THE LOCATION OF THE PIPING RUNS ARE APPROXIMATE AND THE CONTRACTOR COMPLETION OF INSTALLATION AND INITIAL FLUSH, DISINFECT THE WATER SYSTEM PER PROCEDURE OF 37 1 KEC CUSTOM FABRICATION CUSTOM MUST MAKE ANY NECESSARY CHANGES IN THE PIPING RUNS, ETC., AT NO ADDITIONAL LOCAL JURISDICTION OR IF NONE SPECIFIED, BY FILLING IT WITH SOLUTION CONTAINING 50 PARTS PER DOUBLE SIDED SPLASH GUARDS COST TO THE OWNER. OUTLET LOCATIONS ARE CRITICAL AND MUST BE LOCATED EXACTLY MILLION OF CHLORINE AND ALLOW IT TO STAND FOR NOT LESS THAN TWENTY FOUR (24) HOURS BEFORE 38 HAND SINK 1 KEC KROWNE METAL HS-30FL ACCORDING TO THE PLUMBING PLAN. COORDINATE THIS WORK WITH THE INSTALLERS OF FLUSHING THOROUGHLY TO PURGE CHLORINE AND RETURNING/PUTTING IN TO SERVICE. ALTERNATELY USE 45 TEA BREWER WITH DISPENSER 1 OSV BUNN TB6Q/TDO-N-3.5 N EQUIPMENT FURNISHED AND INSTALLED BY OTHERS. REFER TO THE OTHER DRAWINGS FOR 200 PPM FOR 3 FIRS STANDING TIME. FURNISH CLEAN WATER SAMPLES TO THE LOCAL AUTHORITY FOR V DETAILS OF THE BUILDING CONSTRUCTION AND THE OTHER MECHANICAL, ELECTRICAL, AND TESTING AFTER THE LINES HAVE BEEN DISINFECTED. THIS PROCEDURE TO BE IN ACCORDANCE WITH STATE 46.1 ICE MACHINE 1 KEC MANITOWOC IB-1095YC W EQUIPMENT FEATURES. PLUMBING CODE. NOTIFY CM/A/E WHEN JURISDICTION DOES NOT REQUIRE DISINFECTION. B. COORDINATION AND WORKMANSHIP: SCHEDULE THIS WORK SO THAT IT WILL BE PROPERLY 13. CLEANUP: �, N COORDINATED WITH ALL OTHER TRADES. WORKMANSHIP SHALL BE IN ACCORDANCE WITH CLEAN ALL PLUMBING FIXTURES AND EQUIPMENT THOROUGHLY BEFORE FINAL INSPECTION, LEAVING ALL THE BEST PRACTICE FOR THE CLASS OF WORK INVOLVED. WORKMANSHIP SHALL ALLOW READY FOR USE. THE APPLIANCE TO OPERATE AS INTENDED AND BE INSTALLED TO BEST PROTECT THE THE CHEMICAL INJECTION SYSTEMS ARE SUPPLIED BY BUTLER Z PUBLIC AND OPERATORS FROM INJURY OR DAMAGE,AND TO PRESENT A NEAT, PLEASING, 14. GUARANTEE: CHEMICAL AND THEY UTILIZE ENMESHED AIR GAPS AS A MEANS N m AND ORDERLY APPEARANCE. MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR ONE (1) YEAR FROM DATE OF FINAL OF BACKFLOW PREVENTION. IF PRESSURE REQUIRES, BUTLER O ACCEPTANCE. DEFECTIVE WORK AND ALL DAMAGES CAUSED THEREBY WHICH MAY OCCUR DURING THE CHEMICAL WILL SUPPLY A SEPARATE VALVE TO ADJUST THE w N MATERIALS AND PERFORMANCE PRESSURE AS REQUIRED. '� o TERM OF THE AFOREMENTIONED GUARANTEE WILL BE REPAIRED AND/OR REPLACED AT NO EXPENSE TO 1. MATERIALS: THE OWNER. 3 J ALL MATERIALS SHALL BE NEW AND OF THE QUALITY INDICATED BY THE SPECIFIED BRAND NAMES. SUBSTITUTIONS OF MATERIAL OF EQUAL QUALITY BY OTHER FIRST-LINE 15. OWNER'S MANUAL: CONTRACTOR NOTE: MANUFACTURERS MAY BE ACCEPTABLE PROVIDED A LIST OF SUCH SUBSTITUTIONS IS APPROVED WATER HEATER, EXPANSION TANK AND DOMESTIC HOT WATER A WRITING. A SUBSTITUTIONS LIST SHALL BE SUBMITTED IN TRIPLICATE WITHIN FIVE (5) DAYS THEVIDE THE MANUAL SOALLRCONSST OF APT THREE-RINGN OF IS UAL" SO MATTER RECIRCULATION PUMP TO BE FURNISHED BY OWNER AND P 100 AFTER THE CONTRACT IS LET. SUCH AS: GUARANTEE CARDS, CLEANING INSTRUCTIONS, NOTICES TO OWNER, OPERATING MANUALS, AND INSTALLED BY THE CONTRACTOR. MAINTENANCE INSTRUCTIONS THAT MAY BE CONTAINED IN THE SHIPPING CARTONS OR EQUIPMENT CONTRACTOR TO FURNISH AND INSTALL ALL PIPING, FITTINGS AND HOUSINGS. VALVING REQUIRED FOR A COMPLETE AND WORKING SYSTEM. LINE TYPES PLUMBING SYMBOLS "say S_S. SANITARY SEWER LINE T.P. TRAP PRIMER (n sva SS SANITARY PIPING GW. GREASE WASTE LINE T.M.V. THERMOSTATIC MIXING VALVE E -------V------- VENT LINE T.P.R.V. TEMP. PRESSURE RELIEF VALVE t ' GW GREASE WASTE PIPING -------- GAS LINE P.O.C. POINT OF CONNECTION COLD WATER LINE B.F.P. BACK FLOW PREVENTER m o —CD—OD—CD—OD— CONDENSATE PIPING ___ __— HOT WATER LINE G.I./T. GREASE INTERCEPTOR/TRAP VENT PIPING TEMPERED WATER LINE LAM. LAVATORY Va`y a FILTERED WATER LINE UP. URINAL ` SHUT—OFF VALVE W.C. WATER CLOSET V BACKFLOW PREVENTER G.R. GLASS RACK V.T.R. VENT THIRD ROOF A.F.F. ABOVE FINISHED FLOOR C.I. CAST IRON B.F.F. BELOW FINISHED FLOOR � �o„��u C.W. COLD WATER E WATER METER - H.W. HOT WATER W.H. WATER HEATER , T.W. TEMPERED WATER E.C.O. EXTERIOR CLEAN-OUT F.W. FILTER WATER F.C.O. FLOOR CLEAN-OUT F.S. FLOOR SINK W.C.O. WALL CLEAN-OUT F.D. FLOOR DRAIN M.S. MOP SINK m E < H.D. HUB DRAIN S.S. SCULLERY SINK w m m w F.F.D. FUNNEL FLOOR DRAIN F.E.S. FABRICATED ECONOMY SINK m v K.F.D. KITCHEN FLOOR DRAIN H.S. HAND SINK = z ,p Q,m R.F.D. RESTROOM FLOOR DRAIN U.B.S. UNDER BAR SINK ED - m ON w E.M. ELECTRICAL METER U.B.H.S. UNDER BAR HAND SINK G.M. GAS METER I.C.C. ICE CREAM CABINET 55 i' A e1 oe 3 9 20 WC-1 TABLE TO CALCULATE DRAINAGE FIXTURE UNITS FOR GREASE a 3 O ro s WASTE p"O NO PLUMING FI%TURF DRAINAGE FI%TURF UNITS NUMBER OF FIXNRES TOTAL DRAINAGE F%TURF UNITS FD IE CO� HAND SINK 2 2 FS F 'I 12 F a 14 5 8 12 WGQ WGQ FLooR SINK a 6 IS ? N e o LAV D & O FLOOR DRAIN 2 2 4 1s 0 3 16 L FD WC-1 MOP12 1 2 a 3 N 12 1 Q TOTAL DRAINAGE UNITS 28 NO FS a 17 UR 2, O — a 14 I 7 TABLE 10-3 10 11 12 GRAVITY GREASE INTERCEPTOR SIZING FS_ 14 16 19 o LAM DFU'S (1) INTERCEPTOR VOLUME (2) 'Ss / 8 500 GALLONS III 2 13 ii ii ii Iu FD ! 8 46 46. 12 21 (3) 750 GALLONS 24018/// �� - 35 1,000 GALLONS I FS 14 381 / � di -�y-� 1 / 9 45 90 (3) 1,250 GALLONS VC (E)6"SAN / _i - 172 1,500 GALLONS 18 /{ _ _ 18 1 I�-� 216 2,000 GALLONS 307 (3) 2,500 GALLONS IIIIyI/ I X ' 342 3,000 GALLONS L_i 428 4,000 GALLONS --- iii �--I� 576 5,000 GALLONS I�• 720 7,500 GALLONS 2112 10,000 GALLONS 5\01NI k- 45 // 22 ,, 2640 15,000 GALLONS FS SANITARY/GREASE WASTE PLAN KEYED NOTES' u� 9316 o 14 O NEW HAND SINK. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. OF\OPg'W 46 46. 8 _ O NEW PREP SINK. ROUTE 1 1/2" COPPER WASTE PIPE WITH INDIRECT CONNECTION TO FLOOR SINK. PROVIDE AIR GAP �9FLL R. /5/1 N blol £ / PER CODE. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. ________ N ; O NEW ICE MAKER WITH BIN. ROUTE INDIRECT WASTE TO FLOOR SINK. PROVIDE AIR GAP PER CODE. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. ROUTE CONDENSATE FROM WALK-IN COOLER/FREEZER IN WALL AND STUB OUT TO DRAIN INTO FLOOR SINK. USED J Ili APPROVED PIPE MATERIAL PER AHJ AND SLOP CONTINUOUSLY. o rn 36 w24 3 1 CIJ ® OS NEW MOP SINK. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. ly 11 WCO L___�[ ;____ L___ O NEW 3 COMP SINK. ROUTE 1 1/2" COPPER WASTE PIPE WITH INDIRECT CONNECTION TO FLOOR SINK. PROVIDE AIR w 15 L -------- GAP PER CODE. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. F W 42108 O7 NEW CARBONATOR/SODA RACK. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. o n rn M �� O8 NEW SODA MACHINE W/ICE MAKER ABOVE. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. W j co H Y W JDW O NEW ICE TEA BREWER. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. m Q O u U9 541°18 10 NEW WATER CLOSET. REFER TO PLUMBING FIXTURE SCHEDULE FOR INFORMATION. J Z J Q 11 NEW LAVATORY. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. w>- Z J 12 NEW FLOOR DRAIN. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. U rn m 13 DRAIN FROM HEAT SOAK TANK TO DRAIN INDIRECTLY INTO FLOOR SINK. 14 NEW FLOOR SINK. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. r-YID 15 NEW WALL CLEAN-OUT. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. i6 PROVIDE 4" CONDUIT FOR SODA LINES IN WALL. _ r' 17 NEW URINAL. REFER TO PLUMBING EQUIPMENT SCHEDULE FOR INFORMATION. - J 18 POINT OF CONNECTION TO EXISTING 6" SANITARY SEWER PIPING. VERIFY EXACT LOCATION, SIZE, DEPTH, DIRECTION OF " w FLOW AND PIPE MATERIAL OUT IN THE FIELD. o Z N 19 4" VENT THROUGH ROOF. ENSURE VENT THIRD ROOF IS AT LEAST 10'-0"AWAY FROM ALL OUTSIDE AIR INTAKES. w FIELD VERIFY LOCATION. uj 20 NEW GAS WATER HEATER INSTALLED ON CONCRETE CURB. SEE ARCHITECTURAL DRAWINGS FOR CURB DETAILS. SEE (7 PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL WATER HEATER INFORMATION. Q SANITARY + GREASE WASTE PLAN 21 WATER FILTER SYSTEM. REFER TO EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.a Q 22 ROUTE SODA LINES WITHOUT CONDUIT FROM BAG-N-BOX OVERHEAD AND DROP IN NEARBY WALL WITH CONDUIT AT s+AI F; 1/4• - T-v SODA DISPENSER. COORDINATE DROP IN FIELD WITH SODA VENDOR. FIELD VERIFY LOCATION. 23 POINT OF CONNECTION TO EXISTING 4" GREASE WASTE PIPING. ROUTE TO CONNECT TO EXISTING 2,500 GALLON o Q EXTERIOR BELOW GRADE GREASE INTERCEPTOR. VERIFY EXACT LOCATION, SIZE, DEPTH, DIRECTION OF FLOW AND PIPE MATERIAL OUT IN THE FIELD. m (V ZZ 3 `jam vJ P200 PLUMBING SYMBOLS WATER/GAS SUPPLY KEYED NOTES L S_S. SANITARY SEWER LINE T.P. TRAP PRIMER N $ G.W.— GREASE WASTE LINE T.M.V. THERMOSTATIC MIXING VALVE -------V------- VENT LINE T.P.R.V. TEMP. PRESSURE RELIEF VALVE 10 NEW GAS WATER HEATER. SEE PLUMBING FIXTURE SCHEDULE ON SHEET P100 FOR R 22 GAS GAS LINE +P.O.C. POINT OF CONNECTION ADDITIONAL INFORMATION. SET WATER TEMP. FOR 125°F. MAX. V z —— —— COLD WATER LINE B.F.P. BACK FLOW PREVENTER a HOT WATER LINE G.I./T. GREASE INTERCEPTOR/TRAP O 1/2 COLD WATER AND 1/2" HOT WATER LINE DOWN INSIDE WALL TO HAND SINK. b0 o — — — — — TEMPERED WATER LINE LAV. LAVATORY 3/4" COLD AND HOT WATER LINE DOWN INSIDE WALL TO THREE COMPARTMENT SINK FAUCET 15 1 --- -- WC-1 — -- -- — FILTERED WATER LINE OR. URINAL O / Vy A 81M0E _ AND 1/2" COLD AND HOT WATER LINES DOWN TO BELOW SINK FOR CHEMICAL FEED SYSTEM. c 10 --------- HOT WATER RECIRCULATION\ W.C. WATER CLOSET —� l�4 SHUT—OFF VALVE G.R. GLASS RACK c u ? 3 14 ensue s —ens—cns—c"s ens —cns— ns ns—cns—ws—ens—e OS ��� gACKFLOW PREVENTER A.F.F. ABOVE FINISHED FLOOR O PROVIDE 1/2" COLD WATER CONNECTION FROM WATER FILTER TO ICE MAKER WITH BIN. N M 14 •ns es V.T.R. VENT THIRD ROOF B.F.F. BELOW FINISHED FLOOR D� B —� 15 it 0�'J C.I. CAST IRON �M WATER METER 9 COS 3/4" COLD AND HOT WATER DOWN INSIDE WALL TO MOP SINK. C.W. COLD WATER W.H. WATER HEATER ' WE N F 15 31 H.W. HOT WATER E.C.O. EXTERIOR CLEAN—OUT O 1/2" COLD AND HOT WATER DOWN INSIDE WALL TO PREP SINK. T.W. TEMPERED WATER F.C.O. FLOOR CLEAN—OUT I o WC-1 15 o F.W. FILTER WATER W.C.O. WALL CLEAN—OUT L 3/4.. FILTERED WATER UP FROM CARBONATOR. e i LAV 10 F.S. FLOOR SINK M.S. MOP SINK m 6.5 5 6 ❑u TMV-1 I F.D. FLOOR DRAIN S.S. SCULLERY SINK O ROUTE TO CONNECT TO NEW GAS METER'S DEMAND =1455 MBH, (FIELD VERIFY ACTUAL _ E s I 12 WC 1 H.D. HUB DRAIN F.E.S. FABRICATED ECONOMY SINK LOCATION). APPROXIMATE DEVELOPEDLENGTH FROM FURTHEST FIXTURE TO METER BANK m m a s m RTU a — 10 F.F.D. FUNNEL FLOOR DRAIN H.S. HAND SINK 167'-0". CONTRACTOR TO INSTALL LL PROVIDED PRESSURE REGULATOR AT METER FOR 2 PSI m K.F.D. KITCHEN FLOOR DRAIN U.B.S. UNDER BAR SINK SYSTEM. VERIFY EXACT LENGTH, AND INSTALLATION LOCATION IN FIELD. VERIFY WITH GAS co ? m w _ 4 _1 1 13 10 I L — COMPANY FOR EXACT CONNECTION AND METER INSTALLATION GUIDELINES AND REQUIREMENTS �_ R.F.D. RESTROOM FLOOR DRAIN U.BAS. UNDER BAR HAND SINK PRIOR TO WORK. J 26 E.M. ELECTRICAL METER I.C.C. ICE CREAM CABINET — 16 17 4 UR 1 _ I _ I i — G.M. GAS METER ❑ ~ ..m J 1/2" FILTERED WATER LINE DOWN INSIDE WALL AND BASE CABINET SPACE TO ICE MAKER L _ � I NOTE:7 12 11 AND/OR SODA DISPENSOR, AND TEA BREWER. CONTRACTOR TO PROVIDE APPROVED BACKFLOW i ut TMV-1 i 3 ___ _ LAV PROTECTION DEVICE. SEE PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. a 6 13 I� I i E _ _ _ i L — _ 10 I sro—see 7 � I 12 1. REFER TO RISER DIAGRAM ON SHEET P400 FOR PIPE SIZES. 1" COLD WATER INSIDE WALL TO WATER CLOSET. 15 25 I 46 46. O O 11 1/2" COLD WATER AND 1/2" HOT WATER LINE DOWN INSIDE WALL TO LAVATORY. 0 24008 9 2. REFER TO PLUMBING FIXTURE SCHEDULE ON SHEET P100 FOR KEYED NOTES AND 38 2 12 I I 3. REFER TO SHEET FOOD SERVICE DRAWINGS FOR PLUMBING ROUGH—IN INFORMATION. NEW THERMOSTATIC MIXING VALVE (TMV-1) SUPPLIED AND INSTALLED BY PLUMBING CONTRACTOR BELOW SINK AND LAVATORIES AT LOCATIONS INDICATED. SET WATER — III TMV-1 12 v 45 4. HOT WATER RECIRC LINE TO BE RUN DOWN TO THE BACK OF ANGLE STOP. ITEMPERATURE FOR 105°F MAXIMUM. CIRCULATING HOT WATER TO RUN TO THE HOT WATER INLET OF TMV — SEE RISER DIAGRAM ON SHEET P400. SEE DETAIL 9/P410 FOR ADDITIONAL INFORMATION. i i I 13 ROUTE 3/4" COLD WATER DOWN WALL TO WATER FILTER. FIELD VERIFY LOCATION. GAS LOAD SUMMARY 14 1-1/2" COLD AND HOT WATER DOWN TO WATER HEATER. II—II 0 I _ SYSTEM DESIGNATION EQUIPMENT MBH 15 ROUTE 1/2" COLD WATER PIPING BELOW FLOOR FROM TRAP PRIMER TO FLOOR DRAINS. , Lr IJ r--_ —, FIELD VERIFY LOCATION. I >� I I MAU I DOMESTIC WATER GWH WATER HEATER 120 16 POINT OF CONNECTION TO EXISTING 2" COLD WATER SERVICE WITH WATER METER AND i Be I 1 I RPZBFP. VERIFY EXACT LOCATION IN FIELD. sre_ I I SUB—TOTAL 120 III n 17 18 19 I I 17 NEW 2" GAS DOWN TO GAS HEADER FOR COOKING EQUIPMENT. GAS FRYERS (3 KITCHEN 240 80) 1g PROVIDE MANUAL EMERGENCY GAS SHUT—OFF VALVE IN GAS RISER DOWN TO COOKING KITCHEN EQUIPMENT i 123 24 30 g ,Q i KITCHEN CHAR BROILER 105 EQUIPMENT. REFER TO GAS RISER DIAGRAM ON SHEET P400 FOR RISER FOR INFORMATION. 25 19 PROVIDE AUTOMATIC EMERGENCY GAS SHUT—OFF VALVE IN GAS RISER AND TIE INTO ANSUL SUB—TOTAL 345 F " RE SUPPRESSION SYSTEM. REFER TO SHEET MECHANICAL HOOD DRAWINGS AND GAS RISER DIAGRAM ON SHEET P400 FOR INFORMATION. RTU-1 ROOF TOP UNIT 160 20 GAS UP FROM BELOW GRADE, TO 1 1/4" MANIFOLD CONNECTION TO FRYERS, 3 FRYERS RTU-2 ROOF TOP UNIT 200 80 CFH EACH. ' BUILDING HEATING I RTU MAU-1 MAKEUP AIR 480 21 NOT USED. 56 g i 23 20 I I I I D AQUASTAT. SEE PATIO HEAT 3 ® NEW HOT WATER RECIRCULATION WATER PUMP WITH INTEGRATED TIMER AN N bZo19£ I I I PH-1 150 22 50) PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. SET TIMER FOR ( ON AT 8:30 A sre— sve—see— —sre—see—see�sro—sre—sve Lee— J SUB—TOTAL 990 A.M. AND OFF AT BE P.M. DAILY. y 6 272 3/4" GAS UP FROMM BELOW SLAB TO CHARBROILER (105 MBH). ssre see 25 TOTAL NATURAL GAS CONNECTED LOAD 1455 NEW 3/4"HW UP TO ITEM #78 ON ROOF. COORDINATE LOCATION WITH MECHANICAL 36-24 � ® MBH CAPACITY 1455 CONTRACTOR AND OWNERS REPRESENTATIVE. EQUIVALENTLPIPED LENGTHH FOR INCLFITTTNG AND 200 FT X 25 UDING CONDENSATE PIPING TO DISCHARGE ONTO SLOPED ROOF. `'SG1sTE e�c�2 3 2 GAS METER REQUIREMENTS VALVE FRICTION LOSSES TO GAS METER. 1.2=FT 167 2�a18 u 26 3/4" COLD WATER INSIDE WALL TO URINAL. TMV-1 12 a 27 PROVIDE ACCESS PANEL IN CEILING FOR WATER SERVICE SHUT OFF VALVE. 9316 �n CONSULT GAS UTILITY COMPANY FOR REGULATOR RATING IIJD 28 Ll COORDINATE SUB—METER REMOTE READER LOCATION WITH LANDLORD'S REPRESENTATIVE. N� O INSTALL AT ACCESSIBLE HEIGHT. OF�OPgt4 a54�418 29 LANDLORD FURNISHED AND INSTALLED NG STUB UP. HABIT BURGER TO PROVIDE LANDLORD �9FLL R.C'/5/1 WITH UNDERGROUND VAULT BOX. CONTRACTOR TO FURNISH AND INSTALL PATIO HEATER (50MBH) TO LANDLORD PROVIDED STUB UP. PROVIDE DIRT LEG AND SHUTOFF VALVE WITH WATER CALCULATIONS - HABIT BURGER LOCKABLE HANDLE IN ACCORDANCE WITH LOCAL CODE. 77J WATER SUPPLY F.U. WATER SUPPLY NG DROP TO BELOW GRADE FURNISHED AND INSTALLED BY LANDLORD WITH GAS VALVE IN PLUMBING FIXTURE QTY EACH F.0 TOTAL 30 RISER (DRESSER STYLE 175 OR EQUAL), SEE RISER DIAGRAM. J LAVATORY 2 1 2 p WATER CLOSET(FLUSH VALVE) 3 20 60 M W URINAL 1 20 20 cli LLI 3-COMP SINK 1 4 4 30 3 F MOP BASIN 1 3 3 � W 1 BOWL PREP SINK 1 2 2 w M S HAND SINK 2 1 2 4 e W CI w WATER TO SODA/ICE 2 2 4 g TOTAL 99 AQ ;0uj Z J WATER SERVICE SIZE 2" — ML LLI aWATER + GAS SUPPLY PLAN SCALE- va - r-117 2g WALL BACK FLOW PREVENTER ASSEMBLY REQUIREMENTS Z s QUICK DISCONNECT TYPE OF EQUIPMENT METHOD OF CROSS MANUFACTURE AND REMARKS J SUPER SAFE GAS ON SYSTEM CONNECTION CONTROL MODEL NUMBER _ 13— Above-ground gas meters and piping shall be protected by a barrier in an CONNECTOR STAINLESS STEEL BODY WITH QUARTER S approved manner complying with IFC Section 312. CARBONATOR DUAL CHECK VALVE WITH WATTS SD3—QT O IFC 312.2 Posts,Guard posts shall comply with all of the following SODA SYSTEM ATMOSPHERIC PORT ASSE 1022/1024 CERT TURN VALVE SS STRAINER. requirements. KITCHEN GAS — 0 FLEXIBLE APPLIANCE REDUCED PRESSURE WATTS LF-009—QT—S STAINLESS STEEL BODY WITH QUARTER _1 1)Construction of steel not less than 4 inches in diameter and concrete HOSE ICE MACHINE TURN VALVE BRONZE STRAINER. LL_ filled. ZONE ASSEMBLY 2)Spaced not more than 4 feet between posts on center DUAL CHECK VALVE WITH WATTS SD3—QT STAINLESS STEEL BODY WITH QUARTER N 3)Set not less than 3 feet deep in a concrete footing of not less than RESTRAINING TEA MACHINE ATMOSPHERIC PORT TURN VALVE BRONZE STRAINER. Q 15-inches in diameter. ASSE 1022/1024 CERT � V' q& 4)Set posts with the top of the posts not less than 3 feet above ground. FINISHED FLOOR WATTS LF-919—QT WATER REDUCED PRESSURE LEAD FREE CAST COPPER WITH QUATER SERVICE Q � ,0 29 29 ns— s� 5)Posts shall not be located less than 3 feet from the protected object. ZONE ASSEMBLY TURN cns LINE BALL VALVE 1. CONTRACTOR SHALL PROVIDE INDIVIDUAL BACKFLOW PREVENTERS FOR EACH PIECE OF EQUIPMENT. o N BELOW SLAB BELOW GRADE BELOW GRADE 2. EACH BACKFLOW PREVENTER MUST HAVE TESTING PORTS. - w --- GAS PIPING SLEEVE O 3. BRONZE BODIED BACKFLOW PREVENTERS ARE PERMISSABLE IF ALLOWED BY LOCAL CODES. � N Q w BELOW GRADE GAS PIPING DETAIL SCALE: NTS P210 s u. u V W C C •�W ��§mo LL Oj �O wa m ry� ki . 46'-5" ut ill _Ti mai � o 22'_4" c7 z m m m w 18•_9.. � F� N�� 11'-11 0 3 w m 10'-2" 1._4.. J in x 3 ::J - a N i in M I m a I M O yg\VIAL EN O �0%S,T,E�$�,�''i2t( aN 9316 0p OF SELL R•O/5/1 rl J 0 w cli W LU Irn W � M Y Ij co U4 o W m¢ O C U' 2z � ¢ — W z Z J _ Q og Z T C7 Z_ cl O m o N a 'KI L�O FLOOR DRAIN ROUGH-IN PLAN a scaL - r-o� �E: va� P220 /< 2-1/2" 4VM WCO VW / \ JIl / \ WC-1 /^\ �•C �1-1/2" •�U/ gg Fg G 1/2 / 2-1/2" 2 \ \ O" " \ we / 3/4" LAV WC-1 \ 2„ TO CWN- \ lwlV 0 Inm F J vl 4" LAV �U*R I 4 C/`/ \\ 3 w Z � // O 2, y \\ © WATER DOWN TO \ UP THROUGH a 3 IV-/ \\\J 7, WATER FILTER ROOF TO 4 \ 3 2" � � �� \\ 3/4• FS B3/4` 1/2" \ - .. I \ 3/4" I 46 Y EGO \ \, 3/4 / 4, / v1/2" 3/4 3 .,/ 2" 38 �• � -1/2" 1/2N 1/2" WWI 4" \ 2" / \ 1/2" \/ \ BV 4.. FS \\/ 2" 1/2" a' 45 37 NTeRc NN�R2 Sp0 3" FPTpRE4SF ��- �� 1Mv-i SA F / FS WOO BASED 2 PSI 01 PSI DROP �/2„ �55��STE 0 NEW GASS METER DEMAND= 1455 �( �G 3' 2" MBH 0167'-0"TOIL METER.TO PROVIDE PRESSURE REGULATOR 2 PSI WITHH GASECM IN PANyIELD EXACT PRESSURE RE a NEEDED a WATER RISER DIAGRAM 9316 0 PENETRATION (n� al SANITARY RISER DIAGRAM THROUGH ROOF �(1455 MBH) 8CALB NONE o�9rF OF T 1 P SCALE: NONE /4 160 MEN �FLL R•�'/5/1 1/2"DOWN TO N ^J 1335 MBH) MAU-1 BISL-2 GAS WATER HEATER 480 MBH 200 MBH iATER HEATER V -_1/4 % (1175 MBH) (12D MBH) �55 O 3/4" CYO'- 1/2 PENETTHROUGH RROOF ��(830 MBH) LLIcli J 34 S 680 MBH) w (o ^J C3 44 wLLJ EMERGENCY - 4,. SHUT-OFF VALVE \ / Cn M (FIRE STOPPER VALVE) LLI MANUA T-OFF ,,//(�? 00 SHUVALVE i/2 ~ e W C1 Lu FLOOR -(150 MBH) 1/2"G TO® CHARBROILER PENETRATION (105 MBH) sw / 1/2"0 TO FRYERS LLI Z DIRT LEG SOJ 1/2" (((������gRgRgR��� (240 MBH)Q3 /2" PENETRATION _ THROUGH ROOF y - GAS SHUT-OFF VALVE o (DRESSER STYLE 175 OR EQUAL)AND ACCESS PANEL c7 FLOOR PENETRATION PATIO HEATER 50 MBH U) (150 MBH) 1/2 w f`u (50 MBHI-�. �S N of GAS RISER DIAGRAM �f PATIO HEATER / of 3 PATIO HEATER 50 MBH �5 SCALE: NOW (50 MBH) MBH) I 1/Z1'�GA$�GAS__*t* m m o N � 0 d P400 CHROME WALLCOVER MAY EXTEND AS VENT - EXHAUST KIT, FLASHING, a a� 18" AND SCREW WASTE OR VENT & STORM COLLAR c. f ' z DRAIN PIPE SHALL BE CUT AT AN V (457mm) 34 1/2" (86mm) DIA. INSTALL FLUSH W/ ANGLE AS SHOWN. TYPICAL z TOP CLEARANCE FINISHED FLOOR 00 PLUGGED TEE PVC ANGLE BRACING BY GENERAL M5 i REFLECTOR CLEANOUT AIR GAP FIN. FLOOR w/ CONTRACTOR V w INTAKE y $ - � FLOOR LINE � 24" (610mm) ^� �� _ SIDE CLEARANCE LILI VACUUM RELIEF VALVE SHUT—OFF VALVE TO BE LOCATED •mow e�_e RADIANT EMITTER HEAT TRAP L/HEAT TRAP WITHIN 5'-0" OF WATER HEATERS GRID METAL GRATE TO HOT WATER SUPPLY, 140`F -- I ----- BE 1/2 WITH III_ 1/8 BEND IIIJJJ 12" KEEP GREASY PILOT LIGHTING HOLE 1/2 LEFT OPEN. 1/8 BEND IF �I III_ ------ HOT WATER RETURN NOTE: ALL GAS PIPING SHALL " (305mm) HANDS OFF CLEANOUT OCCURS -I _ ' BE FURNISHED AND INSTALLED HEATER HEAD B AT END OF LINE WASTE LINE 100� SAFETY SHUT LENGTH TO SUIT hl BY MECHANICAL CONTRACTOR. N SHUT- OFF CONTROL VALVE, INTIALE SETTING* 1.5 GPM CIRCULATING PUMP _ w m E WASTE LINE EXPANSION TANK C OR EQUIVALENT i HEATER HEAD BASE THERMOMETER I z m m SLIP COLLAR STONE BASE GAS SUPPLY _ _ _ BALL VALVES I GAS COCK SHALL BE m —III—III—III—III—I "LUBROSEAL" BY MUELLER (2820mm) 3" DIA STEEL POST NOTE: 1. ALL FLOOR SINKS MUST BE FLUSH WITH it —III—III—III- COMPANY OR APPROVED EQUAL 3 TILE FLOOR AS SHOWN ABOVE — —III- -III_ 1/2" DIAMETER THINWALL (EMT) 93 � � 1/2" INTERNAL CONDUIT WITH ENDS FLATTENED I DRIP LEG J a (2362mm) PIPING 3/4" x 24 GUAGE PERFORATED PLUMBERS TAPE 84" 6 FLOOR SINK DETAIL 3 WALL CLEANOUT DETAIL BOLT STRAPS TO SOLID T&P RELIEF VALVE W/ FULL (2134mm) SCALE: NONE SCALE: NONE BLOCKING IN WALL WITH 3 80 SIZE DISCHARGE TO DRAIN aI aI / INDIRECTLY TO FLOOR SINK. X 2-1/2" LAG BOLTS, TYPICAL / OF FOUR (4) i DIELECTRIC UNION (TYR) CLEANOUT AND ACCESS 5LB. LEAD FLASHING SHALL BE FORMED TO CHIPPED CONCRETE WITH A POSITIVE COVER. TOP OF COVER CLEANOUT TO BE LOCATED TO BE FLUSH w/ TOP SLOPE TO CLAMP DEVICE. PROVIDE NON- SHRINK SPOUT UNDER LEAD FLASHING IN NON CARPETED AREA OF FLOOR AS REQUIRED TO FACILITATE POSITIVE SLOPE (ANY FLASHING MATERIALS OTHER FLOOR PROVIDE STEEL STAND OR LEG WHEN POSSIBLE. THAN LEAD IS UNACCEPTABLE. MINIMUM WIDTH OF FLASHING SHALL BE 24 KIT FROM MANUFACTURER. FINISHED FLOOR 6"MINIMUM ADJUSTABLE CLEANOU MINIMUM 6" A.F.F. FINISH FLOOR STRAINER SLOPE TO DRAIN NOTE: GAS FIRED WATER HEATER HAS A 3" POWER 1/2" CW GAS SHUT-OFF TO TRAP DIRECT VENT AND 3" COMBUSTION AIR. SYSTEM VALVE — - PRIMER -O CONFORMS TO AGA, ANSI, AND ASTM TESTING AND UNDERGROUND = —� =1 ° -�- MATERIALS STANDARDS. VAULT BOX /B BEND _ WATER HEATER DETAIL 8 BEND IF ' / 1 CLEANOUT OCCURS CAST IRON SCALE NONE AT END OF LINE WASTE LINE, LENGTH FLOOR DRAIN a TO SUIT CORE DRILL 10"0 AND 4"0 HOLES THREADED OR CAULK GAS SERVICE WASTE LINE OUTLET PIPE OUTLET a HANGER ROD PROVIDE A SECTION OF HIGH STONE BASE =III=III=III=III INSULATION ATEACH HANGER NOTE:THE GENERAL CONTRACTOR SHALL PROVIDE A ONE PIECE WATER POIC.MNT. INSULATION MAY BE PROOF MEMBRANE FLOOR AND BASE IN THE TOILET ROOM(S). HALF ROUND OR FULL ROUND AND EXTENDED 2" 9 I GAS FIRED PATIO HEATER DETAIL I FLOOR CLEANOUT DETAIL 4 I FLOOR DRAIN W/TRAP PRIMER o BEYQN° GALVANIZED SHIELD EACH WAY SCALE NONE SCALE: NOW SCALE: NONE PPE yg\ONALEN CONNECT TO SINK FAUCET PROVIDE EXTENSIONS Q CzS 'L AS REQUIRED O��r\SJ`T/E�,/gym TEMPERED WATER a V p TURN LEAD DOWN 3/8" COMPRESSION CONNECTIONS �i SHEET LEAD FLASHING INTO STACK N� O INSULATION MOP-IN WITH ROOFING WHERE REQUIRED �i MATERIAL INSULATION O"9lF COLD WATER MINIMUM 22 GAUGE METAL i�i Ii WHERE REQUIRED 9X9ELL R•G�5/1 STRAP MATERIAL INSTALLED �i z WITHIN THE TOP 1/3 OF iI iI 12' tV TEMPERING MIXING VALVE 3/8" COMPRESSION TEE ROOFING THE HEATER AND BOTTOM i' i� (MIN.) 1/3 OF THE HEATER. HOT WATER STUB OUT IN WALL. DRILL PILOTS ON CENTER - 1/2" COLD AND HOT WATER LINE OF STUD, INSERT �� WALL STUD J 3/8" CHROME TUBING TYP. �'� - - - SCREWS THROUGH PUNCHED i•i HOLES IN STRAP. II II PIPE o '"> USE MINIMUM 1/4" SCREWS �i ROOF STRUCTURE GALVANIZED IRON WITH MINIMUM 1-1/2" Ii 4" MINIMUM SLEEVE ROOF CONSTRUCTION UNISTRUT CHANNEL SHEET SHIELD w PENETRATION. USE WASHERS BETWEEN SCREWS AND \� AS REQUIRED (12" LONG) F COLD WATER STRAP. ®.., CONTROL UNIT NOTES: W STOP VALVES �ii INCREASE AS REQUIRED 1. ATTACH SUPPORTS FOR ALL PIPING SUSPENDED FROM THE STEEL W Q' M THE LOWER STRAP MUST BE NOTE: STRUCTURE TO THE TOP CHORD OF JOISTS OR BEAMS. F- A MINIMUM OF 4"ABOVE CONTRACTOR SHALL °D THE CONTROL UNIT. PROVIDE EXTENSION AS 2. PROVIDE COPPER OR PLASTIC COATED HANGERS FOR NON-INSULATED ~Y W cl w SINK ASQTO ENSURE VENT IP PE COPPER PIPE m RED ON VENTO vi U IS HIGHER THAN PARAPET = 2f J Q METERING CONNECT TOW Z u'� 2-- LAVATORY J TEMPERED WATER— FAUCET al STRAPPING REQUIREMENTS 5 VENT THROUGH ROOF DETAIL aI PIPE HANGER DETAIL 3 m 3/8" COMPRESSION CONNECTIONS SCALE NONE SCALE NONE SCALE NONE COLD WATER 1/2' COLD WATER 2"VENT ROUTED TEMPERING MIXING VALVE5� BYPASS INTO CEILING SPACE OUTLET TO BACK FLOW HOT WATER FOR SODA CARBONATOR - STUB OUT IN WALL. ® SODA BAG-N-BOX - o 1/2" COLD AND HOT WATER UNION 3/8" CHROME TUBING TYP. o�7 TOP OF HALF WALL _ UNION V 1 1/2" ENT FROM F 2 N "V LOOR DRAIN J �3/4" COLD MINIMUM HEIGHT 1,Y MINIMUM VENT PIPING �J WATER INLET �5 INSTALLATION COLD WATER 1/2" OUTLET TO ICE TEA LIJ STOP VALVES MAKER & ICE MAKERS FLOOD RIM OF SINK cl rFT-FT-F I .. ... . . . . . . . . .0 0 q q T RY EVERPURE HI GH FLOW CSR TRIPLE Z LAVATORY 7FC SYSTEM 1 1/2"VENT FROM N 1 1/2" VENT FROM FLOOR DRAIN HAND SINK TOP OF WORK SURFACE (OWNEERR SUPPLIED) TEMPERING WATER MIXING EV HAND SINK (#37) m (V UP 10 VALVE DETAIL 11I WATER FILTER PIPING DETAIL 12I HALF WALL VENT PIPING DETAIL K con SCALE WME SCALE NOW SCALE NONE P41 0 DIVISION 16 - ELECTRICAL SPECIFICATIONS 11. DEMOLITION 13. GROUNDINGg C. POWER CONDUCTORS: NO WIRE LESS THAN N0. 12 SHALL BE USED EXCEPT FOR CONTROL (A A. ALL EXISTING EQUIPMENT, NOT INDICATED TO BE INCORPORATED INTO THE NEW SYSTEM SHALL CIRCUITS OR LOW VOLTAGE WIRING. WIRE SIZES NO. 12 TO NO. 10 SHALL BE SOLID A. CONTRACTOR SHALL INSTALL A SYSTEM GROUNDING SYSTEM &AN EQUIPMENT GROUNDING SYSTEM & BE DISCONNECTED BY THIS CONTRACTOR FOR REMOVAL BY OTHERS FROM THE JOB SITE. EXCEPT WHERE OTHERWISE INDICATED. WIRE SIZES NO. 8 & LARGER SHALL BE STRANDED. SHALL USE ONLY APPROVED GROUNDING CLAMPS &CONNECTORS AS MANUFACTURED BY PENN-UNION, SEC-nON 161M CARE SHALL BE USED SO THAT NO DAMAGE IS DONE TO EXISTING BUILDING, PIPING, ALL WIRE SIZES SHOWN ARE AMERICAN WIRE GAUGE SIZES. SIZES NO. 12 AWG THROUGH NO. BURNDY, OR 0-Z MFG. COMPANY. ` V DUCTWORK,AND/OR ELECTRICAL EQUIPMENT. ANY DAMAGE ATTRIBUTED TO THIS CONTRACTOR 8 AWG SHALL BE DUAL-RATED TYPE"THHN/THWN"INSULATION. SIZE 4 AWG& LARGER SHALL o ELECTRICAL SPEGAL CONDf110NS SHALL BE REPAIRED OR REPLACED BY THIS CONTRACTOR. BE 'THW." B. THE SYSTEM GROUNDING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE ELECTRICAL CODES& �� F 1• � D. CONTINUITY: ALL WIRES SHALL BE CONTINUOUS FROM OUTLET TO OUTLET. THE UTILITY COMPANY REGULATIONS. CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE w LL A. APPLICABLE PROVISIONS OF AIA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FOR 12. CUTTING AND PATCHING CONDUCTORS TO THE NEUTRAL BAR INSIDE THE MAIN PANEL. WHEN TRANSFORMERS ARE USED TO Vy E. ACCEPTABLE MANUFACTURERS: CABLE&WIRE SHALL BE STANDARD TYPE AS MANUFACTURED PROVIDE A SEPARATELY DERIVED SYSTEM,THE CONTRACTOR SHALL CONNECT THE GROUNDING CONSTRUCTION", & DIVISION 1 GENERAL CONDITIONS GOVERN WORK UNDER THIS SECTION &ALL A. ALL CUTTING THAT MAY BE NECESSARY FOR THE INSTALLATION OF THE WORK E ANY ELECTRODE CONDUCTOR TO THE NEUTRAL BAR INSIDE THE SECONDARY SYSTEM PANEL OR SERVICE BY GENERAL CABLE COMPANY, CAROL, ANACONDA, ROM OR ITT ROYAL c OTHER SECTIONS OF DIVISION 16. REQUIRED PATCHING THAT RESULTS THEREFROM SHALL BE DONE BY THE PROPER TRADE RATED DISCONNECT SWITCH, DO NOT CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE •gym = ==e INVOLVED &SHALL BE INCLUDED AS PART OF THIS CONTRACT. PATCH TO DUPLICATE NEUTRAL LUG INSIDE THE TRANSFORMER. B. APPLICABLE PROVISIONS OF THIS SECTION GOVERN WORK UNDER ALL OTHER SECTIONS OF UNDISTURBED ADJACENT FINISHES, COLORS,TEXTURES& PROFILES. COLUMNS, BEAMS, F. ALL WIRE IN THE WORK SHALL BE COPPER. 00 goew DIVISION 16. WORK COVERED BY THIS SECTION SHALL CONSIST OF PROVIDING ALL MATERIAL, GIRDERS OR JOISTS SHALL NOT BE CUT. C. THE EQUIPMENT GROUNDING SYSTEM SHALL CONSIST OF A CONTINUOUS CONDUIT INSTALLATION &A - LABOR, EQUIPMENT& SERVICES NECESSARY FOR A COMPLETE,TESTED &ADJUSTABLE ELECTRICAL g, COLOR CODING GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR. THIS GROUNDING CONDUCTOR SHALL BES LL?V INSTALLATION READY FOR OPERATION AS SPECIFIED HEREIN &AS SHOWN ON THE DRAWINGS. B. ALL WORK AFFECTING ROOF OR STRUCTURES SHALL BE PERFORMED BY LANDLORD'S INSTALLED IN EVERY CONDUIT OR RACEWAY WITH THE FEEDER OR BRANCH CIRCUIT CONDUCTORS.THIS C. THE TERM CONTRACTOR AS USED IN THIS SECTION SHALL MEAN ANY CONTRACTOR OR CONTRACTOR AT TENANT'S EXPENSE. A. A COLOR CODING SYSTEM AS LISTED BELOW SHALL BE FOLLOWED THROUGHOUT FOR GROUNDING SHALL BE EXTENDED FROM THE HOUSING OF EVERY ELECTRICAL LOAD,THROUGH FEEDERS & BRANCH CIRCUITS & USED AS A BASIS FOR BALANCING LOAD. PANELBOARD STATIC GROUNDING BUSSES, TO THE STATIC GROUNDING BUS IN THE MAIN PANEL.THE SUBCONTRACTOR WHO HAS CONTRACTED TO PERFORM WORK INCLUDED IN & DEFINED BY THIS 13. CLEANING GROUNDING BUS SHALL BE BONDED TO THE GROUNDING NEUTRAL BAR INSIDE THE MAIN PANEL. wo SECTION &ALL OTHER SECTIONS OF DIVISION 16. --120/208V: PHASE A--BLACK, PHASE B--RED, PHASE C--BLUE, COMPLETION AS IT PERTAINS TO THE CONTRACT COMPLETION DATE IS DEFINED AS THE NEUTRAL--WHITE, GROUND--GREEN SIBILITY DAY THE PROJECT IS TURNED OVER TO THE OWNER IN THOROUGHLY CLEAN CONDITION. 14. LIGHTING FIXTUR HA. PRIOR TO SUBMITTING HIS BID, CONTRACTOR SHALL CAREFULLY EXAMINE THESE CONSTRUCTION READY FOR THE OWNER TO TAKE POSSESSION. ALL FIXTURES, MOTORS, EQUIPMENT& --277/480V: PHASE A--BROWN, PHASE B--ORANGE, PHASE C--YELLOW, A. ALL LIGHTING FIXTURES& LAMPS/DRIVERS SHALL BE FURNISHED BY G.C., UNLESS NOTED OTHERWISE.DOCUMENTS,THE DEVELOPER'S EXHIBITS, &THE SITE,TO INQUIRE FULLY INTO DIFFICULTIES & ALL OTHER ELECTRICAL EQUIPMENT FURNISHED OR INSTALLED BY THE CONTRACTOR NEUTRAL--GRAY, GROUND--GREEN wCOSTS OF WORK, &TO DETERMINE THE SCOPE&CHARACTER OF WORK TO BE DONE. SHALL BE THOROUGHLY CLEANED. THIS CONTRACTOR SHALL INSTALL LIGHTING FIXTURES & LAMPS/DRIVERS AS INDICATED ON THEDRAWINGS &AS SPECIFIED BELOW, COMPLETE WITH HANGERS, PLASTER FRAMES &ALL OTHER wCONTRACTOR SHALL INCLUDE ALL NECESSARY COSTS TO LOCATE AND/OR EXTEND ALL UTILITIES 14. 7. BOXES AND FDTINGS NECESSARY ACCESSORIES.INCLUDING LIGHTING PANELS, POWER PANELS, ELECTRICAL SERVICE, PHONE SERVICE AND/OR A. PROVIDE THE TESTS AS OUTLINED HEREINAFTER&OTHER TESTS NECESSARY TO A. ALL OUTLETS SHALL BE PROVIDED WITH GALVANIZED OR SHERARDIZED BOXES SUITABLE IN MODIFY EQUIPMENT TO MEET THE INTENT OF THE CONTRACT DOCUMENTS.THE OWNER, OWNER'S B. ALL BALLAST, DRIVERS, STARTERS& LAMPHOLDERS IN FLUORESCENT LIGHTING EQUIPMENT ARE TO BEESTABLISH THE ADEQUACY, QUALITY, SAFETY, COMPLETED STATUS& SUITABLE OPERATION DESIGN TO THE SPACE THEY OCCUPY&THE PURPOSE THEY SERVE. WALL MOUNTED OUTLET zN x AGENT,ARCHITECT, ENGINEER OR DESIGNER SHALL NOT BE RESPONSIBLE FOR FAILURE OF THE DIMMABLE, ELECTRICAL TESTING LABORATORIES, UNDERWRITERS LABORATORIES & CERTIFIED BALLAST a OF EACH SYSTEM. CORRECT PROMPTLY ANY FAILURE OR DEFECTS REVEALED BY THESE BOXES, EXCEPT FOR 2"PARTITIONS SHALL BE AT LEAST 1 1/2"DEEP AND/OR DEEPER IF CONTRACTOR TO DETERMINE DIFFICULTIES &COSTS IN THE PROJECT OR FOR HIS OVERLOOKING TESTS& RECONDUCT TEST ON THE CORRECTED ITEMS. REQUIRED BY THE DEVICE THEY HOLD OR CODES. MANUFACTURERS APPROVED.ALL BALLAST FOR FLUORESCENT FIXTURES SHALL BE OF THE HIGH POWER OF THE REQUIREMENTS. FACTOR TYPE& SHALL BE GENERAL ELECTRIC "MAXI-MISER II"OR ADVANCED MARK III. WHERE B. TEST THE GROUNDS WITH A GROUND RESISTANCE DIRECT READING SINGLE-TEST MEGGER. B. ALL PULLBOXES SHALL BE MADE OF GALVANIZED STEEL, OF METAL GAUGE& PHYSICAL SIZE OCTRON LAMPS ARE SPECIFIED PROVIDE APPROPRIATE BALLASTS. PROVIDE ALL DIMMING B. IF THIS CONTRACTOR DOES NOT CLEARLY UNDERSTAND THE PLANS&SPECIFICATIONS, OR IF AS REQUIRED BY THE NEC FOR THE NUMBER &SIZE RACEWAYS& CONDUCTORS BALLASTS/DRIVERS AS REQUIRED BY ENERGY CODES. THERE ARE ANY REQUIREMENTS WHICH ARE AMBIGUOUS IN THE CONTRACTOR'S OPINION, HE C. INSULATION RESISTANCE BETWEEN PHASE CONDUCTORS& GROUND NOT LESS THAN INVOLVED. SHOULD CALL THIS TO THE ATTENTION OF THE ARCHITECT PRIOR TO BIDDING, SINCE THIS 1,000,000 OHMS. C. THIS CONTRACTOR SHALL VERIFY THE FINAL CEILING & FINISH SCHEDULES TO INSURE THE PROPER CONTRACTOR WILL BE HELD RIGIDLY TO THE INTERPRETATIONS OF THE ARCHITECT& ENGINEER. C. FIXTURE OUTLET BOXES IN OR ON CEILINGS SHALL NOT BE LESS THAN 1-1/2"DEEP OR INSTALLATION & MOUNTING OF FIXTURES&SHALL COORDINATE BEFORE MAKING SUBMITTALS. C. CONTRACTOR SHALL SCHEDULE HIS WORK IN COOPERATION WITH OTHER TRADES INSTALLING D. THE PANELBOARDS SHALL HAVE PHASE CURRENTS BALANCED TO WITHIN +/- 10% LESS THAN 4"SQUARE.ALL OUTLET BOXES INTENDED TO SUPPORT FIXTURES SHALL BE D. AIM ALL ADJUSTABLE LIGHT FIXTURES AS DIRECTED BY ARCHITECT/ENGINEER. INTERRELATED WORK. ALL WORK SHALL BE SCHEDULED TO MAINTAIN SERVICE TO ALL REQUIRED VARIATION BETWEEN AVERAGE PHASE CURRENT& MEASURED INDIVIDUAL PHASE. EQUIPPED WITH 3/8"FIXTURE STUDS FASTENED THROUGH THE BOTTOM OF THE BOX WITH AREAS DURING THE COURSE OF THE CONSTRUCTION EXCEPT FOR SHORT TERM PLANNED E AN OPERATIONAL TEST OF THE EMERGENCY LIGHTS&THE EXIT LIGHTS SHALL BE FOUR BOLTS. E. PROVIDE AN UNSWITCHED, CONSTANT ON CIRCUIT TO ALL EMERGENCY LIGHTING BATTERY PACK CHARGING E.SHUTDOWNS,ANY OF WHICH SHALL BE PRE-SCHEDULED WITH THE OWNERS AGENT&THE PERFORMED FOR THE OWNER TO DEMONSTRATE CONFORMANCE TO THE SPECIFICATIONS. B. CIRCUIT BREAKER PANELBOARDS CIRCUITS. LANDLORD. 3. WORKMANSHIP AND GUARANTEE 15. TEMPORARY ELECTRICAL SERVICE A. PANELS SHALL BE DEAD FRONT, SAFETY TYPE, FURNISHED WITH BRANCH CIRCUIT PROTECTING 15. TIMECIOCKC A. TEMPORARY ELECTRICAL SERVICE SHALL BE IN ACCORDANCE WITH THE BUILDING CODE. DEVICES, EQUIPMENT GROUNDING BOX, MAIN BUS & CABLE LUGS FACTORY ASSEMBLED, WITH A. IN ENTERING INTO A CONTRACT COVERING THIS WORK,THE CONTRACTOR ACCEPTS THE TEMPORARY LIGHTING SHALL BE PROVIDED BY A LAMP LOCATED FOR EVERY 625 SQUARE ALL COMPONENTS IN PLACE, READY FOR INSTALLATION. PROVIDE 20%SPARE BREAKER A. ANDTIMECLOCKS SHALL N MANUFACTURED BY INTERMATIC, OR OWNER AND ENGINEER APPROVED EQUAL, SPECIFICATIONS, & GUARANTEES THAT THE WORK WILL BE CARRIED OUT IN ACCORDANCE WITH FEET OF BUILDING AREA WITH A MINIMUM OF ONE PER ROOM. THE LAMP TO BE 100 WATT CAPACITY&25% EXCESS AMPACITY IN EACH PANEL. AND AS SPECIFIED ON THE DRAWINGS. THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. CONTRACTOR FURTHER GUARANTEES & SHALL BE MAINTAINED BY THE GENERAL CONTRACTOR. B. CURRENT CARRYING CONTACT SURFACES SHALL BE SILVER OR TIN PLATED. THE CIRCUIT THAT THE WORKMANSHIP& MATERIAL WILL BE OF THE BEST PROCURABLE&THAT NONE BUT BREAKERS SHALL BE OF THE MOLDED CASE, BOLT-ON TYPE SUITABLE FOR VOLTAGE& 16. TELEPHONE SERVICE EXPERIENCED WORKMEN EXPERIENCED IN EACH PARTICULAR CLASS OF WORK WILL BE B. TEMPORARY POWER DISTRIBUTION SHALL BE SUFFICIENT TO ACCOMMODATE THE TEMPORARY AMPERE RATINGS INDICATED ON DRAWINGS& IN SCHEDULES &SHALL HAVE A MINIMUM A. THIS CONTRACTOR SHALL INSTALL A TELEPHONE SERVICE CONDUIT AS SHOWN ON THE DRAWINGS & EMPLOYED. CONTRACTOR FURTHER GUARANTEES TO REPLACE& MAKE GOOD AT HIS OWN LIGHTING &CONSTRUCTION OPERATIONS, INCLUDING THE USE OF POWER TOOLS (BUT NOT INTERRUPTING CAPACITY OF 10,000 AMPERES FOR 120/208V& 14,000 AMPERES AT FURNISH & INSTALL(1) 2' X 2' X 3/4"FIRE-TREATED PLYWOOD PANEL MOUNTED ON THE WALL AT EXPENSE ANY DEFECTS DUE TO FAULTY WORKMANSHIP OR MATERIAL WHICH MAY DEVELOP INCLUDING HEAVY-DUTY ELECTRICAL WELDING UNITS), ELECTRICAL HEATING UNITS, & 277/480V. LOCATION SHOWN ON PLANS. WITHIN ONE (1)YEAR AFTER FINAL PAYMENT&ACCEPTANCE OF THE WORK. START-UP OF SPECIFIED BUILDING EQUIPMENT, WHICH IS TO BE TESTED, STARTED OR PLACED INTO USE PRIOR TO COMPLETION OF ITS PERMANENT POWER CONNECTIONS. C. MAIN BUSES &CONNECTORS SHALL BE HARD DRAWN COPPER OF 98% CONDUCTIVITY,WITH 17. SURFACE METAL RACEWAY 4. CODES AND STANDARDS CURRENT CARRYING CAPACITY TO MAINTAIN ESTABLISHED RISE TESTS AS DEFINED IN ILL 16. IXCAVATION AND BACKFlLL STANDARD ILL 67. A. SURFACE METAL RACEWAY SHALL BE TWO PIECE#2100 AS MANUFACTURED BY WIREMOLD. ALL A. CONTRACTOR WILL COMPLY IN ALL RESPECTS WITH THE ADOPTED BUILDING CODES, A. CONTRACTOR SHALL DO ALL EXCAVATION REQUIRED AS SHOWN ON PLANS OR REQUIRED NECESSARY ACCESSORIES REQUIRED TO FIT THE CONFIGURATION SHOWN SHALL BE PROVIDED. APPLICABLE LAWS, ORDINANCES, & REGULATIONS AS MAY APPLY ACCORDING TO THE RULING FOR PROPER OPERATION. EXCESS EXCAVATION BELOW THE REQUIRED LEVEL SHALL BE D. CABINET SIZES ARE BASED UPON A 20"WIDE BY 6"DEEP PANEL UNLESS OTHERWISE NOTED. RECEPTACLES SHALL BE 120 VAC, 20 AMPS, CATALOG NUMBER #2127GT. OF THE CONTROLLING PUBLIC OFFICIAL SHOULD THE CONTRACTOR PERFORM ANY WORK BACKFILLED WITH EARTH &THOROUGHLY TAMPED. UTILITY SERVICES, SHALL BE PANELBOARDS SHALL BE EQUIPPED WITH FLUSH TYPE LOCK &CATCH. ALL LOCKS SHALL BE THAT DOES NOT COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE LAWS, ORDINANCES INSPECTED&APPROVED BY THE PROPER INSPECTION AUTHORITY BEFORE BACKFILLING. KEYED ALIKE, &TWO KEYS ARE TO BE SUPPLIED WITH EACH LOCK. 18. TRANSFORMER & REGULATIONS, OR WHICH DOES NOT RECEIVE THE APPROVAL OF THE CONTROLLING A. FURNISH & INSTALL G.E. TYPE "QL"DRY TYPE TRANSFORMER WITH 6 2-1 2%CAPACITY TAPS ON THE PUBLIC OFFICIAL, HE SHALL BEAR ALL COSTS ARISING CORRECTING THE DEFICIENCIES. E. FURNISH & INSTALL AS SHOWN ON PLANS. LIGHTING PANELBOARDS BY SQUARE-D TYPE "NF", PRIMARY WINDING (TWO ABOVE& FOUR BELOW NORMAL VOLTAGE). TRANSFORMER SHALL BE RATED FOR ALL ELECTRICAL EQUIPMENT SHALL SHALL BEAR THE UNDERWRITER'S LABORATORY LABEL SECTION 16200 WITH BOLT-ON CIRCUIT BREAKERS OR AN APPROVED SUBSTITUTION. ADDITIONAL BREAKERS 150'C RISE ABOVE 40'C AMBIENT DURING USE& HAVE AN INSULATION SYSTEM RATED TO WITHSTAND 5. FEES ON PERMITS ELECTRICAL POWER AND LIGHTING FOR EXISTING PANELBOARDS SHALL BE OF TYPE MATCHING THE EXISTING BREAKERS. 220'C. EQUIVALENT SUBSTITUTION BY SQUARE-D, SIEMENS OR WESTINGHOUSE WILL BE ACCEPTABLE. A. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING & MAKING PAYMENT FOR ALL FEES, PERMITS& INSPECTIONS RELATING TO HIS WORK. 9. TOGGLE SWITCHES END OF DIVISION 16 1. RELATED DOCUMENTS 6. CONTRACT DRAWINGS APPLICABLE PROVISIONS OF AIA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT A. TOGGLE SWITCHES SHALL MATCH DECOR, & SHALL BE RATED 20 AMPERES 120/277 VOLT AC ELECIRCAL LEGEND TYPE AS MANUFACTURED LIKE HUBBELL&SHALL BE AS FOLLOWS: A. THE DRAWINGS SHOW THE GENERAL ARRANGEMENT& INTENT OF THE DESIGN & SHALL BE FOR CONSTRUCTION", DIVISION 1 GENERAL CONDITIONS& SECTION 16100 ELECTRICAL SYMBOL DESCRIPTION FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONDITIONS &THE WORK OF OTHER TRADES WILL SPECIAL CONDITIONS GOVERN WORK UNDER THIS SECTION. SINGLE POLE --1221--1 PERMIT. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE THREE WAY--1223--1 ® EQUIPMENT CALLOUT - SEE EQUIPMENT& PANEL SCHEDULES FOR MORE INFORMATION ALL OFFSETS, FITTINGS, &ACCESSORIES WHICH MAY BE REQUIRED, NOR IS IT IMPLIED THAT ALL B. REFER TO SECTION 16100 ELECTRICAL SPECIAL CONDITIONS REGARDING REGULATIONS& CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE SYSTEMS OR BUILDING COMPONENTS HAVE REQUIREMENTS AFFECTING ALL WORK DESCRIBED IN THIS SECTION. B. TOGGLE SWITCHES SHALL BE MOUNTED 4'-0"ABOVE FINISHED FLOOR TO MOUNTING PLATE AND, DUPLEX RECEPTACLE MOUNTED AT 18"AFF UNLESS NOTED OTHERWISE BEEN INDICATED.THE CONTRACTOR SHALL INVESTIGATE ALL EXISTING CONDITIONS AFFECTING THE AT DOORS, INSTALLED ADJACENT TO THE TRIM ON THE STRIKING SIDE OF THE DOOR, WORK&ARRANGE HIS WORK ACCORDINGLY, PROVIDING SUCH FITTINGS, OFFSETS,ACCESSORIES 2. POWER SERVICE REGARDLESS OF THE LOCATION INDICATED ON THE DRAWINGS;THEREFORE, CHECK ALL DOOR QUAD FLEX RECEPTACLE MOUNTED AT 18"AFF UNLESS NOTED OTHERWISE Q�AL & DEVICES AS MAY BE REQUIRED. THE DRAWINGS &SPECIFICATIONS ARE MUTUALLY SWINGS BEFORE INSTALLATION OF CONDUIT OUTLETS. Fh COMPLEMENTARY, &ANY WORK REQUIRED BY ONE BUT NOT BY THE OTHER SHALL BE A. POWER SERVICE FOR THIS PROJECT SHALL BE PROVIDED AS SHOWN ON DRAWINGS. THE DUPLEX GFCI PROTECTED RECEPTACLE MOUNTED AT 18"AFF UNLESS NOTED OTHERWISE PERFORMED.THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL MATERIALS& ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MANAGEMENT TO INSURE THAT ALL WORK &SERVICES REQUIRED FOR A COMPLETE&WORKING PROJECT AT NO ADDITIONAL COST EVEN MATERIALS ARE IN CONFORMANCE WITH THE LANDLORD'S REQUIREMENTS. C. COMPARABLE EQUIPMENT AS MANUFACTURED BY SLATER, LEVITON, & BRYANT WILL BE QUAD PLEX GFCI PROTECTED RECEPTACLE MOUNTED AT 18"AFF UNLESS NOTED OTHERWISE O to 71 Q Q` TO a THOUGH EACH & EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN. ACCEPTABLE. 3 � QJ JUNCTION BOX 9316 B. CONTRACTOR SHALL NOT SCALE FROM THE DRAWINGS BUT SHALL FOLLOW THE ARCHITECTURAL D. ALL 20AMP/120/277V SWITCHES SHALL BE SPECIFICATION GRADE. 1P O DRAWINGS OR EXISTING BUILDING CONDITIONS WHERE APPLICABLE, IN ESTABLISHING DIMENSIONS A. ELECTRICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO, PANELBOARDS, DISCONNECTS 'Q- MOTOR CONNECTION �1 .�• & LINES OF RUN, SINCE DIMENSIONS ON THE FINAL ARCHITECTURAL DRAWINGS OR AT THE SITE TRANSFORMERS, CONTROLS, ETC., SHALL BE IDENTIFIED WITH THREE PLY LAMINATED E. WHERE MORE THAN ONE SWITCH OCCURS AT THE SAME LOCATION, THEY SHALL BE SET IN EII DISCONNECT SWITCH �y9�FpF\�Pg� MAY NOT COINCIDE WITH THOSE SHOWN ON THE ELECTRICAL DRAWINGS,THE CONTRACTORS PLASTIC. THE OUTSIDE LAMINATIONS SHALL BE BLACK. ENGRAVING SHALL EXTEND THROUGH GANGS WITH ONE COVERPLATE, INSTALLED IN BOXES IN UNIFORM POSITION, SET TO OPEN & SHALL VERIFY WITH THE DIMENSIONED ARCHITECTURAL DRAWINGS OR THE SITE CONDITIONS THE THE FRONT LAMINATION SO THAT THE WHITE LETTERS APPEAR IN A BLACK FIELD. CLOSE CIRCUITS BY MOVING IN THE SAME DIRECTION THROUGHOUT THE JOB. = SINGLE SECTION PANELBOARD ELLR•�'P EXACT MATERIAL QUANTITIES& LENGTHS NECESSARY. NAMEPLATES SHALL BE PERMANENTLY ATTACHED WITH SCREWS. I5I1 F. SWITCH & RECEPTACLE PLATES SHALL BE BRUSHED STAINLESS STEEL. �� BRANCH CIRCUIT WIRING CONCEALED ABOVE CEILING OR IN PARTITION C. SIGNIFICANT DEVIATIONS OR CHANGES FROM THE DRAWINGS WHICH ARE REQUIRED TO B. CIRCUIT DIRECTORY SHALL BE TYPEWRITTEN (HANDWRITTEN IS NOT ACCEPTABLE) &SHALL ACCOMPLISH THE INTENT OF THE CONTRACT DOCUMENTS MUST BE REVIEWED WITH THE IDENTIFY CIRCUIT AS TO TYPE& LOCATION AS FOLLOWS: 10. RECEPTAC R --- CIRCUIT HOME RUN - 3/4"C.-2#12+1#12G, U.O.N. ARCHITECT&APPROVED BEFORE PROCEEDING. "LTG" - FOR LIGHTING CIRCUIT FOLLOWED BY AREA IN WHICH CIRCUIT APPEARS, I.E., A. RECEPTACLES SHALL MATCH DECOR, MANUFACTURED LIKE HUBBELL&SHALL BE AS FOLLOWS: "STOCKROOM", "CASH WRAP", ETC. ® VERIFY NEMA CONFIGURATION REQUIRED WITH EQUIPMENT SUPPLIER 1 7. SHOP DRAWINGS "RECEPT" - FOR RECEPTACLE CIRCUIT FOLLOWED BY AREA IN WHICH RECEPTACLE APPEARS, B. DUPLEX RECEPTACLE --20A-120 VOLT 5362-1 A. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, FOUR (4) COPIES MINIMUM, FOR ALL MANUFACTURED "STOREFRONT", "CASH REGISTER", ETC. ROUGH-IN FOR TELEPHONE DATA LINE OR DATACOM MOUNTED AT 18"AFF UNLESS NOTED OTHERWISE CD PRODUCTS. EACH SHOP DRAWING SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL "MOTOR"- FOR MOTOR FOLLOWED BY THE EQUIPMENT IDENTIFICATION &AREA IN WHICH C. RECEPTACLES SHALL BE MOUNTED 18"ABOVE THE FINISHED FLOOR UNLESS OTHERWISE NOTED. 0 ROUGH-IN FOR TELEPHONE VOICE LINE MOUNTED AT 18"AFF UNLESS NOTED OTHERWISE R `ct TO ASSURE THAT ALL DIMENSIONS, QUANTITIES, CONNECTIONS, CAPACITATES&ACCESSORIES MOTOR IS LOCATED, I.E. "EXH FAN TOILET", "AHU-ROOF", ETC. OUTLET IS MEASURED FROM CENTER OF BOX TO FINISHED FLOOR. LLI SHOWN ARE IN CONFORMANCE WITH THE CONTRACT DOCUMENTS, &SHALL BE MARKED OR # WALL MOUNTED TOGGLE SWITCH OR DIMMER SWITCH14- cli STAMPED TO CONFIRM THAT SUCH REVIEW WAS MADE&COMPLIANCE WAS CONFIRMED. 4. CONDUfT D. COMPARABLE EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, SLATER, BRYANT W & LEVITON WILL BE ACCEPTABLE. $3 3-WAY WALL MOUNTED TOGGLE SWITCH OR DIMMER SWITCH B. APPROVAL OF SHOP DRAWINGS BY THE OWNER, OWNER'S AGENT,ARCHITECT, ENGINEER OR A. ALL WIRING SHALL BE RUN IN CONDUIT.ALL CONDUIT RUNS CONCEALED IN WALLS SHALL BE /G TIMECLOCK & LIGHTING CONTROLS LLI DESIGNER, WILL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF COMPLYING WITH ALL EMT FOR SIZES 1/2"THROUGH 2-1/2".ALL CONDUITS LARGER THAN 2-1/2"SHALL BE E. ALL RECEPTACLES SHALL BE SPECIFICATION GRADE. TERMS OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR HEAVYWALL CONDUITS INSTALLED UNDERGROUND OR IN CONCRETE SLABS SHALL BE PVC MS WALL MOUNTED MOTION SENSOR/MANUAL LIGHT SWITCH COMBINATION W M PERFORMANCE OF ALL EQUIPMENT PURCHASED, FOR PROPER FIT, & OTHER DIMENSIONAL JACKETED. FLEXIBLE STEEL CONDUIT (SEALTITE) SHALL BE USED IN WET AREAS&ON ALL F. ALL ISOLATED GROUND (I.G.) RECEPTACLES SHALL BE ORANGE IN COLOR. REQUIREMENTS. MOTORIZED EQUIPMENT. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS,AT A CEILING MOUNTED MOTION SENSOR (WATTSTOPPER #LMPL-101, OR APPROVED EQUAL) Y Lu O W MAXIMUM LENGTH OF 6 FEET,WHERE NOT CONCEALED IN A WALL. NO BX,AC OR NM ALLOWED, G. ALL 120V DUPLEX AND QUAD RECEPTACLES SHALL BE "DECORATOR"STYLE. 8. RECORD DRAWINGS MC MAY BE USED ABOVE ACCESSIBLE CEILING. @ CEILING MOUNTED MOTION SENSOR (HUBBELL #PIR10P, OR APPROVED EQUAL) m Q O Ur A. CONTRACTOR SHALL MAINTAIN AT THE JOB SITE ONE SET OF DOCUMENTS AS "RECORD H. ALL DUPLEX RECEPTACLES IN PUBLIC AREAS (I.E. - ENTRY QUEUE, DINING ROOM, HALLWAY, Ell MLV DIMMER/MANUAL LIGHT SWITCH COMBINATION(LEVITON#AWSMG-MAW,OR APPROVED EQUAL) J B. WHERE INSTALLED OUTDOORS &ABOVE GROUND, IN POURED CONCRETE OR SUBJECT TO STRESS RESTROOMS,AND PATIO AREAS) SHALL BE TAMPER RESISTANT TYPE RECEPTACLES. =Z Q DRAWINGS" FOR THE PURPOSE OF DAILY MARKING OF ALL SUBSTANTIAL REVISIONS TO THE FROM COLLISION OR IMPACT, CONDUIT SHALL BE GALVANIZED RIGID STEEL.WHERE RIGID D2 MARK10 DIMMER/MANUAL LIGHT SWITCH COMBINATION(LEVITON#AWSMG-XAW, OR APPROVED EQUAL) - DOCUMENTS INCLUDING BUT NOT LIMITED TO ELECTRICAL CHANGES, & LOCATIONS OF CONDUIT IS NOT REQUIRED, CONDUCTORS SHALL BE INSTALLED IN ELECTRICAL METALLIC TUBING I. ALL ENTRY QUEUE, DINING ROOM,AND HALLWAY DUPLEX RECEPTACLES SHALL BE DARK BROWN IN air u'� Z J UTILITIES, PANELBOARDS, DISCONNECTS, STARTERS & OTHER DEVICES REQUIRING PERIODIC WITH ELECTRO-GALVANIZED OUTSIDE ENAMEL INSIDE. WHERE CONDUIT IS INSTALLED COLOR. D3 INCAN. DIMMER/MANUAL LIGHT SWITCH COMBINATION (LEVITON#AWSMG-IAW,OR APPROVED EQUAL) Z - OPERATIONAL ATTENTION, ADJUSTMENT, OR SERVICE INCLUDING ACCESS THERETO, AT THE UNDERGROUND, CONDUIT SHALL BE PVC AS PERMITTED BY LOCAL AUTHORITIES. D4 REMOTE DIMMER rn COMPLETION OF THE PROJECT, THIS SET SHALL BE RETURNED TO THE ARCHITECT. J. ALL SHOW WINDOW RECEPTACLE SHALL BE WHITE IN COLOR. ❑ /MANUAL LIGHT SWITCH COMBINATION(LEVITON #AWSRT-OOW, OR APPROVED EQUAL) U m 1. ALL OPENINGS IN FIRE& SMOKE WALLS, PARTITIONS, FLOORS& OTHER SIMILAR 9. EOUIPMENf SUBSTTTl1T1ON PENETRATIONS FOR ELECTRICAL CONDUITS, CABLE OR EQUIPMENT, WHETHER CUT OR IN PP DAYLIGHT ZONE DIMMING POWER PACK K. ALL RESTROOMS DUPLEX RECEPTACLE SHALL BE WHITE IN COLOR. C10 PLACE, SHALL BE CLOSED WITH A UL APPROVED FIRE RESISTANT SILICONE FOAM SEALANT R DAYLIGHT ZONE DIMMING RELAY PACK W A. THE CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH ALL TERMS OF THE CONTRACT ❑ DOCUMENTS.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR PERFORMANCE OF ALL TO MAINTAIN THE FULL RATING& INTEGRITY OF THE PARTITIONS, WALLS OR FLOOR. L. ALL RECEPTACLE IN FOOD PREP AND KITCHEN AREA SHALL BE GFCI TYPE. ~ EQUIPMENT PURCHASED, FOR PROPER FIT, &OTHER DIMENSIONAL REQUIREMENTS. © DAYLIGHT ZONE CEILING-MOUNTED, DUAL-ZONE, PHOTOCELL O 2. O.Z. TYPE DX,TX, OR AX CONDUIT EXPANSION DEFLECTION FITTINGS ARE REQUIRED IN 11. DEVICE PLATES Z ALL CONDUIT RUNS WHERE MOVEMENT MAY BE ENCOUNTERED. ALL EMT COUPLINGS p �p p B. IF THIS CONTRACTOR SUBSTITUTES FOR SPECIFIED EQUIPMENT ANY OTHER EQUIPMENT WHICH AOI�r1ATKM - SHALL BE COMPRESSION TYPE. Z REQUIRES ANY CHANGES TO THE DESIGN,ALL COST OF REDESIGN & RECONFIGURATION A. DEVICE PLATES SHALL BE STAINLESS STEEL UNLESS OTHERWISE NOTED. COMPARABLE RESULTING FROM SAID SUBSTITUTION SHALL BE BORNE BY THE CONTRACTOR. EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, HARVEY HUBBLE INC., A -AMPERE MLV - MAGNETIC LOW VOLTAGE - Q 3. EXPOSED CONDUIT SHALL ER SECURELY SUPPORTED IN PLACE PER CODE BUT ON A BRYANT& LEVITON WILL BE ACCEPTABLE. PAINT MATCH ADJACENT FINISH COLOR. g 10. EQUIPMENT INSTALLATION AND SUPPORT MAXIMUM OF 10 FOOT INTERVALS, WITHIN THREE FEET OF EACH BEND,AT EVERY OUTLET AFT -ABOVE FINISHED FLOOR T.G.C. -TENANT'S GENERAL CONTRACTOR Ua OR JUNCTION BOX &AT THE END OF EACH STRAIGHT RUN TERMINATING AT A BOX OR Z B. ALL KITCHEN/EXPO/FOOD-PREP SWITCH/DIMMER AND RECEPTACLE COVER PLATES SHALL BE CB -CIRCUIT BREAKER V -VOLT o Z A. CONTRACTOR SHALL SUPPORT PLUMB, RIGID &TRUE-TO-LINE ALL WORK & EQUIPMENT CABINET. CONDUIT SHALL NOT BE SUPPORTED FROM DUCTWORK OR PIPE WORK. CONDUITS Q INSTALLED. THIS CONTRACTOR SHALL DETERMINE HOW EQUIPMENT, FIXTURES, ETC.,ARE SHALL BE RUN PARALLEL TO&AT RIGHT ANGLES TO THE BUILDING LINES. GENERALLY, BRUSHED STAINLESS STEEL. _ TO BE SUPPORTED, MOUNTED, OR SUSPENDED &SHALL PROVIDE ACCESSORIES REQUIRED CONDUIT SHALL BE RUN IN CONTACT WITH STRUCTURAL PARTS OF THE BUILDING SO AS E.C. - ELECTRICAL CONTRACTOR P.O.S. - POINT OF SALE Q ALL ENTRY QUEUE, DINING ROOM,AND HALLWAY DUPLEX RECEPTACLE COVER PLATES BE DARK C. A V FOR PROPER SUPPORT WHETHER SHOWN ON THE DRAWINGS OR NOT. IF SUPPORTS ARE TO AVOID SUSPENDED LENGTHS OF CONDUIT. CONDUIT SHALL BE INSTALLED AS TO BE FLA - FULL LOAD AMPS INCL - INCLUDED REQUIRED, CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR APPROVAL. ACCESSIBLE FOR REPLACEMENT& MAINTENANCE& GENERALLY CONDUIT SHALL BE BROWN IN COLOR (TO MATCH RECEPTACLE COLOR). INSTALLED TO PERMIT DRAINAGE. ES.E.C.- FOOD SERVICE EQUIPMENT CONTRACTOR 20AS - 20 AMP SWITCH LL_ B. PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS PRINTED D. ALL SHOW WINDOW RECEPTACLE COVER PLATES SHALL BE WHITE IN COLOR (TO MATCH G.C. -GENERAL CONTRACTOR 20AF - 20 AMP FUSE V INSTALLATION & MAINTENANCE LITERATURE, COMPONENTS REQUIRING PERIODIC RECEPTACLE COLOR). W MAINTENANCE OR ADJUSTMENTS SHALL BE LOCATED OR INSTALLED AS TO PERMIT ACCESS 5. WIRE AND CABLE K.E.C. - KITCHEN EQUIPMENT CONTRACTOR G - GROUND WIRE Ek- WITHOUT DAMAGE TO STRUCTURE, FINISHES OR OTHER EQUIPMENT. E. ALL RESTROOM DUPLEX RECEPTACLE COVER PLATES SHALL BE WHITE IN COLOR (TO MATCH GFl -GROUND FAULT INTERRUPTER C - CONDUIT co A. ALL WIRE&CABLE SHALL BE RUN IN CONDUIT.ALL WIRE&CABLE FEEDERS& BRANCH WITH RECEPTACLE COLOR). J C. ALL CONDUIT CONNECTING TO SWITCHGEAR, PANELS, MOTORS, &OTHER EQUIPMENT SHALL CIRCUITS SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE CURRENT EDITION OF THE HP - HORSEPOWER A.I.C. -AMPERE INTERRUPTING CAPACITY f;L_LL_LL BE INSTALLED WITHOUT STRAIN AT THE CONNECTIONS.THE CONTRACTOR MAY BE C.E.C. & SHALL MEET ALL ASTM SPECIFICATIONS. WIRE & CABLE SHALL BE NEW, SHALL 12. DISCONNECT SWITCHES REQUIRED,AS DIRECTED, TO DISCONNECT CONDUITS TO DEMONSTRATE THAT THEY HAVE HAVE SIZE, GRADE OF INSULATION VOLTAGE& MANUFACTURER'S NAME PERMANENTLY MARKED KW - KILOWATT EF - EXHAUST FAN U BEEN SO CONNECTED ON OUTER COVERING AT REGULAR INTERVAL& SHALL BE DELIVERED IN COMPLETE COILS OR A. FURNISH & INSTALL DISCONNECT SWITCHES AS REQUIRED BY CODE. DISCONNECT SWITCHES N.I.F.S.C.-NOT IN FOOD SERVICE CONTRACT MAU - MAKE-UP AIRE UNIT _ REELS WITH IDENTIFYING SIZE & INSULATION TAGS. SHALL BE NEMA HEAVY DUTY TYPE & UNDERWRITERS LABORATORIES LISTED, MANUFACTURED BY SQUARE D CORPORATION, ITE, GENERAL ELECTRIC, OR WESTINGHOUSE. NL - NIGHT NIGHT RTU - ROOF-TOP UNIT B. THE ELECTRICAL CONTRACTOR SHALL CALCULATE VOLTAGE DROP ON CONDUCTORS WITH P.C. - PLUMBING CONTRACTOR kVA - KILO-VOLT AMPERE N J 1.ALL "LIKE"EQUIPMENT/DEVICES SHALL BE SINGLE MANUFACTURER. (I.E.;ALL LENGTHS GREATER THAN 75 FEET FROM THE PANELBOARD& PROPERLY SIZE THE B. SAFETY SWITCHES SHALL BE FURNISHED& INSTALLED AT ALL LOCATIONS INDICATED ON PLANS W CONDUCTORS PER CODES. STUB-UP -SERVICE UP FROM FINISHED FLOOR TIC -TIMECLOCK SWITCHGEARS/PANELBOARDS = ONE MANUFACTURER,ALL WIRING DEVICES = ONE OR REQUIRED BY CODES.ALL SWITCHES SHALL BE HEAVY DUTY TYPE& SHALL HAVE CLIPS / MANUFACTURER,ALL LIGHTING SWITCHES DIMMERS = ONE MANUFACTURER, ETC.... FOR REJECTION TYPE FUSES & SHALL BE BY SQUARE-D, G.E. OR AN APPROVED WE -WEATHER PROOF / ) N.L. - NIGHT LIGHT(ALWAYS-ON) SUBSTITUTION, FOR THE VOLTAGE& LOAD INVOLVED. PROVIDE A COMPLETE SET OF FUSES S INCAN. - INCANDESCENT E 100 ALL FUSED SWITCHES. FUSES SHALL BE CLASS AK-1 (BUSSMAN "LOW-PEAK") FOR CIRCUITS UP TO 600 AMPS & CLASS L(BUSSMAN "HI-CAP" KRP-C) FOR CIRCUITS ABOVE 600 AMP. GENERAL NOTES Q� LK`#i11NG PLAN KEYED NOTES 1. THE SCOPE OF THE ELECTRICAL WORK SHALL INCLUDE FURNISHING,INSTALLING&TESTING ALL ELECTRICAL SYSTEMS FOR A COMPLETE&FULLY OPERABLE 0 i"ar INSTALLATION COMPLY WITH LATEST VERSION OF ALL APPLICABLE NATIONAL,STATE&LOCAL CODES. _ _ O EMERGENCY EGRESS/EXIT FIXTURES SHALL BE ON ANON-SWITCHED LEG OF CIRCUIT INDICATED. C� RNAL) f�' z EMERGENCY FIXTURES SHALL HAVE THE EMERGENCY BALLAST UNSWITCHED AND THE FIXTURE 2. LOCATIONS OF EXISTING ELECTRICAL SYSTEM,EQUIPMENT&DEVICES SHALL BE FIELD VERIFIED BY THE TENANT'S GENERAL CONTRACTOR(T.G.C.). 9 `' V BALLAST SHALL BE SWITCHED.CIRCUIT BREAKER SHALL BE CLEARLY MARKED WITH THE INTENDED a USE&HAVE A"LOCK-ON"DEVICE INSTALLED. 3. CONTRACTOR SHALL VISIT THE SITE&FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS UNDER WHICH HE IS TO PERFORM HIS WORK.NO ALLOWANCE $ WILL BE MADE FOR FAILURE TO COMPLY. '" O2 PROVIDE TIMECLOCK&LIGHTING CONTACTORS FOR INTERIOR/EXTERIOR LIGHTING CONTROL.SEE X3 V v LL DETAIL#2,SHEET E410,FOR MORE INFORMATION.COORDINATE WITH OWNER FOR CONTROL 4. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS&SHALL IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY DISCREPANCIES. SCHEDULE(S)&ADDITIONAL REQUIREMENTS.FIELD VERIFY EXACT MOUNTING LOCATIONS nr i WA ...;... �� 5. COORDINATE LOCATIONS&ROUTING OF FEEDERS TO PANELBOARDS WITH LANDLORD&PROVIDE ALL NECESSARY APPURTENANCES AS REQUIRED BY _ LANDLORD&OWNER. 03 CONTRACTOR TO INSTALL A CEILING MOUNTED OCCUPANCY SENSOR(HUBBELL#PIR10P,OR L LLD3N ® • DrR APPROVED EQUAL)FOR LOCAL LIGHTING CONTROL.CIRCUIT RESTROOM EXHAUST FAN WITH 6. WHERE THE WORD"PROVIDE"IS USED,THE WORD IS UNDERSTOOD TO MEAN"THE ELECTRICAL CONTRACTOR SHALL FURNISH,INSTALL&MAKE FINAL DZ"; .::''+:"II RESTROOM LIGHTING FOR SIMULTANEOUS OPERATION. CONNECTION TO THE EQUIPMENT",UNLESS OTHERWISE NOTED. ® D3N '5• oA " _ • S LLE V ®LIGHTING FIXTURES E.SWITCHES FOR THE WALK-IN COOLER/FREEZER ARE TO BE PROVIDED WITH 7, REFER TO LANDLORD'S DESIGN SPECIFICATION FOR ADDITIONAL REQUIREMENTS&INFORMATION. ® a OOOO COOLER/FREEZER(E.G.TO PROVIDE,IF NOT SUPPLIED).FIXTURES&SWITCHES ARE TO BE F� \ INSTALLED BY E.C.PER MANUFACTURER'S REQUIREMENTS&N.E.C.ARTICLE 300-7.PROVIDE ALL 8. REFER TO ALL DISCIPLINES,INCLUDING ARCHITECTURAL&KITCHEN PLANS FOR ADDITIONAL INFORMATION,REQUIREMENTS AND WORK REQUIRED BY E.C., NECESSARY DEVICES&MAKE ALL FINAL CONNECTIONS. PROVIDE ALL LABOR&MATERIAL AS REQUIRED. N � O5 PROVIDE W.P.JUNCTION BOX WITH DISCONNECT SWITCH FOR CONNECTION TO BUILDING SIGN. 9. ALL CONDUITS ARE TO BE CONCEALED IN WALLS OR ABOVE CEILINGS.CONDUITS IN EXPOSED CEILING AREAS SHALL EXIT WALLS AS CLOSE TO ROOF/FLOOR 3N VERIFY EXACT LOCATION&POWER REQUIREMENTS PRIOR TO ANY WORK.COORDINATE INSTALLATION STRUCTURAL DECK AS POSSIBLE. PF WITHSIGN VENDOR&OWNER.BUILDING SIGNS CONTROLLED THRU TIMECLOCK&PHOTOCELL. f10, ANY EXISTING MATERIALS OR EQUIPMENT NOT TO BE REUSED MUST BE COMPLETELY REMOVED&DISPOSED OF PROPERLY.NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. ®EXHAUST HOOD LIGHTS MOUNTED PRE-WIRED JUNCTION BOXES.E.C.SHALL COMPLETE CIRCUITING p:; _. M g mKRCHENFOR HOOD LIGHTING,SEE HOOD DRAWINGS FOR MORE INFORMATION.G.C.SHALL PROVIDE HOOD p7.: -LAMPS ORDERED THRU HABIT BURGER'S LIGHTING VENDOR. 11, ALL OPERABLE CONTROLS DEVICES,SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 48"&NO LOWER THAN 18"ABOVE THE 103 � :FLOOR PER A.D.A.REQUIREMENTS.RESOLVE ANY CONFLICT IN MOUNTING HEIGHT WITH ARCHITECT/OWNER PRIOR TO ROUGH IN. >LIGHTING SWITCHBANK LOCATION.SEE DETAIL#2,THIS SHEET,FOR MORE INFORMATION. e1112. THE DIRECTIVE,IF ANY,OF THE BUILDING OFFICIAL SHALL TAKE PRECEDENCE OVER THIS DRAWING REGARDING LOCATION&NUMBER OF EXIT LIGHTS. EM2 NCONTRACTOR TO ENSURE ALL LIGHTING FIXTURES HAVE PROTECTIVE COVERS OR SHATTERPROOF 13. ALL WIRING SHALL BE COPPER.MINIMUM WIRE&CONDUIT SIZE SHALL BE 12 THHN IN 3 4'CONDUIT OR AS REQUIRED BY CODE. 1 'BULBS IN KITCHEN AND FOOD PREPARATION AREAS. # /" .H'O9PROVIDE PHOTOCELL&CONNECTION TO AC BALLAST FOR NORMAL DUSK-TO-DAWN OPERATION. 14. SUSPENDED ELECTRICAL CONDUITS&OUTLET BOXES ARE TO BE SUPPORTED FROM THE STRUCTURE USING METAL BRACES. FIXTURE TO BE WIRED FOR DUSK-TO-DAWN&EMERGENCY BATTERY BACKUP OPERATION. 15. ANY PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE APPROPRIATELY FIRE STOPPED TO RETAIN THE WALL'S RATING.THROUGH PENETRATIONS OF / b ;'; • . O10 AUDIO EQUIPMENT&INSTALLATION BY OTHERS.PROVIDE A 6 GANG MUD RING WITH P RING FIRE-RATED ASSEMBLIES SHALL BE PROTECTED BY AN APPROVED THROUGH-PENETRATION FIRE-STOP SYSTEM INSTALLED&TESTED IN ACCORDANCE WITH K1 D3N - COVERS ABOVE LIGHT SWITCHES CLEAR OF OBSTRUCTIONS),DEDICATED FOR AUDIO CONTROLS ASTM 814 OR UL1479 WITH A MINIMUM POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER(2.49Po).THE SYSTEM SHALL HAVE AN"F"RATING& - - • A'T"RATING OF NOT LESS THAN 1-HOUR,BUT NOT LESS THAN THE REQUIRED RATING OF THE WALL PENETRATED. COORDINATE REQUIREMENTS WITH AUDIO SYSTEM PROVIDER.PROVIDE(1)3/4"EMPTY CONDUIT X STUBBED UP ABOVE CEILING TO ROUTE AUDIO CONTROL WIRES.AUDIO INSTALLER SHALL \ / EM1' COORDINATE INSTALLATION WITH ALL OTHER DISCIPLINES.SEE SWITCH BANK DETAIL,DETAIL#2, ' THIS SHEET FOR MORE INFORMATION. o \� 1 OLM1 7 D5 d .3N'„ 11 EXTEND LIGHTING CIRCUIT C-1c DOWN INSIDE WALL TO POWER RECEPTACLE FOR PASS SHELF K1 \ / D4F °. LIGHTNG.RECEPTACLE PASS SHELF LIGHTING SHALL BE CONTROLLED PER SWITCHED LEG OF THE Y / • 3N EM2 1 3N 3 D N D3N LIGHTING CIRCUIT FOR DIMMED OPERATION.SEE TYPICAL ASSEMBLY PASS SHELF LIGHTING DETAIL I \ / 10 J • • • U5� • #1,SHEET E410 FOR MORE INFORMATION. I A/ a foe 12 DESIGNATED 2'x2'SPACE(MINIMUM)ABOVE ACT CEILING,REQUIRED BE CLEAR OF ALL CEILING X © D3N f 5S 5S f 5S D55 ITEMS(ELEC,MECH,STRUCT,ETC.)FOR HOOD ACCESS. 1 KM/N OO K2/N D4F D3N • • • ;' 3 f D3N LIGHTING FINISH KEY AND NOTES d EXPO 3 - • • COM TYPE>AREA OR TYPICAL FIXTURE FINISH(COLOR) SF LOW TYPE NOTE VERIFY ALL FIXTURE FINISIM W LX#NNC VENDOR - I / • L3 SPOT LIGHTING ALL TABLES&ARTWORK WILL HAVE 10 DEGREE SPOT LAMPS,AIM TO CENTERED DURING INSTALLATION. D4F D3N• f =- - ' • 3N DINING AREA SOFFITS ALL RECESSED DOWNUGHTS SHALL HAVE WHITE FINISH ON BOTH REFLECTOR&TRIM. =L = fi -._ • L2 DINING AREA SOFFITS ALL ARTWORK SHALL HAVE A DROP ELBOW IN BRUSHED STAINLESS STEEL FINISH. FOOD PREP D3 - L3 L f 104 _ RESTROOMS&VESTIBULE ALL DOWNUGHTS&ELBOWS SHALL HAVE A WHITE FINISH. --- -• �- SERNCE AREA HARDLID ALL DOWNUGHTS&ELBOWS SHALL HAVE A BRUSHED STAINLESS STEEL FINISH. K1 K1 1 ------ TECTUM CEILING ALL DOWNLGHTS&MONOPOINTS LOCATED WITHIN THE TECTUM SHALL HAVE A WHITE FINISH. (6 �� •. 1- rt --= 3N NOTE:CONTRACTOR TO REMOVE ALL FACTORY INSTALLED CLEAR GLASS LENSES FROM DOWNLGHTS FIXTURES. - i„� L3: 13 • u i \ D3 I L3 L3 GENERAL LIGHTING NOTES - D S 3N 1. GENERAL CONTRACTOR SHALL ORDER ALL LIGHI NG FIXTURES,LAMPS,&ALL LIGHTING C-4 ` __ •3N • CONTROL DEVICES THROUGH HABIT BURGER APPROVED LIGHTING VENDOR. `< (PARTIAL) IxMING F` d'' 2. ALL LIGHTING TO BE CONTROLLED BY AUTOMATIC LIGHTING CONTROL.COORDINATE WITH � h D3N OWNER FOR LIGHTING CONTROL SCHEDULES. EM/N • • 3. ALL LIGHTING FIXTURES SHALL HAVE PROTECTIVE COVERS OR SHATTERPROOF BULBS IN K1 'K2 'O P KITCHEN,FOOD PREPARATION AREAS,FRONT SERVICE AREAS,&DISHWASHING AREAS. KS11 11D5S 5\Q1\AL Fh 4. SEE ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION ON FIXTURE LOCATIONS. H�I� • 3N Q14�CjNz, CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REVIEWING ARCHITECTURAL ELEVATIONS FOR D3N 3N • Q �(r ANY ADDITIONAL POWER REQUIREMENTS FOR SIGNS&BUILDING LIGHTING. • • DSS a 9316 p 5. INSTALL LIGHT FIXTURES . ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS&THE 5 f f N O LATEST EDITION OF THE N.E.C.. 6. ALL FIXTURES TO BE PROVIDED BY,RECEIVED,STORED BY THE G.C.&INSTALLED BY THE -1 <, EM 1 it �� 11 L IJ II 099��F E.C. ALL FIXTURE LAMPS SHALL BE SUPPLIED BY THE G.C.&INSTALLED BY THE E.C.. D3N - 3N �/I1 pP 03 03 03 03 • • ELL R- AUDIO AUDIO AUDIO AUDIO 7. TESTING FOR EMERGENCY LIGHTING SYSTEM IS REQUIRED.CONTRACTOR SHALL TEST THE O K2/N PANEL PAN L PANEL C- EM2 1 D f D N /5/1 CONTROL CONTROL CONTROL CONTROL SYSTEM PRIOR TO FINAL INSPECTION(TESTING MUST BE BY DISCONNECTING THE MAIN). "C" "B' "A" C • • 8. PROVIDE ILLUMINATED EMERGENCY POWER PER 2013 IBC,SECTION 1006.3. - 9. EMERGENCY EXTERIOR LIGHTING&ILLUMINATED EMERGENCY POWER SHALL BE INSTALLED IN C-g D3N D3N D3N D3N D3N UN J COMPLIANCE TO THE 2013 IBC,SECTION 1006.3. f L2. 9 3N 9 3N • • x • • • 10. EXIT PATH ILLUMINATION TO BE PROVIDED WITH EMERGENCY BACK-UP POWER SUPPLY.THE f E o MEANS OF EGRESS SHALL BE ILLUMINATED WITH A MINIMUM INTENSITY OF NOT LESS THAN 1 ® ® ® ® FOOT-CANDLE AT THE FLOOR LEVEL(PER IBC SEC.1006.2).CONTRACTOR TO SUPPLY I 5S 1 EM2 55 100 Lu ADDITIONAL(CODE COMPLIANT)EMERGENCY EGRESS FIXTURES AS NEEDED TO COMPLY. D S KITCHEN KITCHEN EXPO/ EXPO/ O S O • W � LIGHTING LIGHTING COUNTER MENUBOARD 11. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION&EXACT MOUNTING C 7 • D3N D3N GENERAL DECOR LOCATIONS OF ALL LIGHTING FIXTURES.VERIFY CEILING TYPE&PROVIDE NECESSARY • L2 L2 • • - W UGHTING LIGHTING MOUNTING HARDWARE TO ACCOMMODATE LIGHT FIXTURES USED.PROVIDE SLOPE CEILING 5 ADAPTERS WHERE REQUIRED.CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING I 0 G_' m C-1 C-1 C-1 C-1 ARCHITECTURAL DRAWNGS FOR ANY ADDITIONAL POWER REQUIREMENTS. L2 f L2 f D3N g O X1 W F- 12. ALL PENDANT HUNG FIXTURES SHALL BE SUPPORTED DIRECTLY FROM STRUCTURE ABOVE Y LL Cl W e f 1 2 3 WITH No.9 GAGE WIRE OR APPROVED ALTERNATE SUPPORT WITHOUT USING CEILING u 0 m 3 ® ® 9 . . O SUSPENSION SYSTEM FOR DIRECT SUPPORT. Q C 0 13. ALL GRID MOUNTED TROFFER LIGHTING FIXTURES MUST BE SUPPORTED BY#12 GAUGE WIRE 9 -9 =Z Q TIMECLOCK DINING DINING ATTACHED TO THE GRID MEMBERS WITHIN 3"OF EACH CORNER OF EACH FIXTURE& (PA ) O O PAT PATIO I - J W Z J OVERRIDE TABLE& DECOR DAYLIGHTING PATIOINDEPENDENTLY SUPPORTED FROM BUILDING STRUCTURE(OTHER THEN THE CEILING GRID). 6- - - SWITCH HALLWAY LIGHTING NORTH HEATER HEATER HEATER 5 Z _ LIGHTING OS OS QS 14. COORDINATE LOCATION OF SWITCH BANK WITH OWNER. _ - O U m 15. EXIT FIXTURES TO BE CIRCUITED BY UNSWITCHED LEG&PROVIDE CONTINUOUS ILLUMINATION L - J C-2 C-3 C-5 C-3 C-11 C-11 C-11 PER N.E.C.700-12(A)&NFPA 101,LIFE SAFETY CODE. N LOCATION:ON BACKSIDE OF WALL BY FRONT E COUNTER IN THE KITCHEN/EXPO AREA.DO NOT '--�` t-^-i . ING LOCATE BEHIND ANY EQUIPMENT. LEGEND NOTE P"� BATH FANS TO BE INTERCONNECTED - W 10 SEE ELECTRICAL LEGEND,SHEET COO,FOR DIMMER/MANUAL SWITCH DESIGNATION. SEE LIGHTING FIXTUREY SCHEDULE,SHEET E201 FOR - O TIMECLOCK OVERRIDE SWITCH,SEE SHEET E410 FOR MORE INFORMATION. ADDITIONAL FIXTURE INFORMATION&QUANTITIES. 28 ®PROVIDE A 6 GANG MUD RING WITH P RING COVERS,ABOVE LIGHT SWITCHES WITH LIGHTS TO RUN WHILE __ (CLEAR OF OBSTRUCTIONS),DEDICATED FOR AUDIO CONTROLS,COORDINATE Z Z REQUIREMENTS WITH AUDIO SYSTEM PROVIDER.PROVIDE(1)3/4"EMPTY LIGHTING VENDOR RESTROOM IS OCCUPIED. o CONDUIT STUBBED UP ABOVE CEILING TO ROUTE AUDIO CONTROL WIRES. _ Z ®SINGLE POLE SWITCH. HEATHER MANAGER �` - T/ -m Q 5 SEE SHEETS E210&E400 FOR PATIO HEATER INFORMATION. Wb PROJECT MANAGER O � < > WIEDENBACH BROWN I THE ULTIMATE LIGHTING SOURCE _ _ Z W I E D E IN B A C H T:781.619.60771 F:914.846.1371 \I J 2 SWITCH BANK DETAIL BROWN EMAIL:heatheryurdie@wNight.com 31 SCALES N.T.B 2 r o CV a LIGHTING PLAN = °' N 1 SCALE: llV-r E200 (A xa all LIGHTING SCHEDULE v U SYMBOL TYPE DESCRIPTION MANUFACTURER FIXTURE PART NUMBER LAMP PART NUMBER VOLTAGE WATTAGE QTY. pD o 4"LED MR16 DOWNLGHT-FROSTED GLASS LENS WITH HOLE IN THE SP3120717 W/ - - - M a D2F CENTER&WHITE TRIM-VESTIBULE TO RESTROOMS. ELITE:TRIM B1427-WH 27-03(36 DEGREE FLOOD 00943) 120V 7.5W 2 Vyo 4"MR16 ADJUSTABLE DOWNLIGHT-RECESSED TRIM WITH WHITE GO Q D3F FINISH-DINING AREA SOFFITS FOR GENERAL ILLUMINATION AT JUNO:HOUSING SP31200-10W/ SM16-07-36D-927-03 120V 7.5W 0 ENTRY DOORS /JUNO:TRIM 444W-WH (36 DEGREE FLOOD 00943) FAS G 4'MR16 ADJUSTABLE DOWNLGHT-RECESSED TRIM WITH WHITE HNIS eaam'� O DUN -DINING AREA HARD LID&TECTUM FOR GENERAL ILLUMINATION TEAS JUNO:HOUSING SP31200-10W/ SM16-07-25D-927-03 120V 7.5W 44 oAA,o RECEPTACLES,EXPO,BEVERAGE,&WAITING BENCH /JUNO:TRIM 444W-WH 25 DEGREE NARROW FLOOD 00931) rs n Q D4F 4°MR16 ADJUSTABLE DOWNLGHT-RECESSED TRIM WITH SILVER FINISH SP3120710W/ - - 120V 7.5W 4 -GENERAL ILLUMINATION AT SERVICE WINDOW ADJACENT TO EXPO AREA ELITE:TRIM B1402-SN-SN 927-03(36 DEGREE FLOOD 00943) D5F 4"'E DOWNLIGHT-PULL-DOWN ELBOW WITH SILVER FINISH SP31200-10W/ - - 120V 7.5W 7 -M N AR TI W ELITE:TRIM 14 -N 27-03 36 DEGREE FLOOD DO-943 m 4"MR16 DOWNLIGHT-PULL-DOWN ELBOW WITH SILVER FINISH- SP31200-IOW/ Q D5S M - - 120V 7.5W 20TO HIGHLIGHT ALL ARTWORK IN DINING ROOM SOFFIT AREAS. /ELITE:TRIM B1406-SN 927-03 NAA(10 DVIVU2EGREE SPOT 09) r m m a ® 6"LED 1000 LUMEN DOWNLIGHT WITH WHITE METAL TRIM- TC922LEDG4-3K-U D7 RESTROOMS JUNO:TRIM 27W_WH 3000K INTEGRAL LED 120V 18W 8 t7 -m romw 4"MR16 DOWNLIGHT-RECESSED TRIM WITH METAL STEPPED BL4-20M-120-AT/ � 2 m J El BAFFLE RATED FOR WET LOCATION-DRI ELITE VE-THRU CANOPY AREA B1417BK-BK - 120V 20W 0 - 7 O DL-22-LF-XEC-FOCUS 120V 20W 0 _ E2 EXTERIOR DOWNLIGHT RATED FOR WET LOCATION AT TRELLIS FA104-FA22-TBOX- INDUSTRIES DR20-NL-WBR E3 EXTERIOR UPLIGHT IN PLANTERS WALKWAYS FOCUS DL-22-LF-XEC- _ 120V 20W 0 J a / INDUSTRIES FA104-FA22-TBOX- DR20-NL-WBR;BLACK FINISH 20W LITHOLOGY-UGHTHAUS WL-16-F BLACK e E3-L EXTERIOR IN-GROUND LANDSCAPE LIGHTING;FINISH BLACK PHILIPS HADCO IL-9-D-W-3000K-A CUSTOM BOB W/PHILIPS LUMILEDS 120V 20W 0 LUXEON M 3000K EPLA EXTERIOR POLE MOUNTED LED SITE LIGHTING FIXTURE IN BLACK; LSI INDUSTRIE XLCM-3-LED -SS- 4000K LED PANEL MOUNTING HEIGHT 25FEET. INC. NW-UE 25'M SINGLE- INTEGRAL DRIVER 120V 181W 0 25'MH EPLB EXTERIOR POLE MOUNTED LED SITE LIGHTING FIXTURE IN BLACK; LSI INDUSTRIE XLCM-3-LED-SS- 4000K LED PANEL MOUNTING HEIGHT 25FEET. INC. NW-HSS-BLK-SINGLE- INTEGRAL DRIVER 120V 181W 0 25'MH 2x4 2-LAMP GRID TROFFER-WITH ADVANCE MARK 10 JT824-232G-FSAI2-EU K1 TWO-WIRE DIMMING BALLAST&INTERNAL DISCONNECT SWITCH- COLUMBIA KITCHEN/FOOD PREP W/pDVMK 10 USHIO(2)F32T8/830 120V 68W 9 2x4 2-LAMP GRID TROFFER-WITH ADVANCE MARK 10 JT824-232G-FSAI2-EU K2 TWO-WIRE DIMMING BALLAST&INTERNAL DISCONNECT SWITCH- COLU BIA W/ADVMK 10&BEST USHIO(2)F32T8/830 120V 68W 6 EM 1400 LUMEN BATTERY-KITCHEN/FOOD PREP BAL1400 FIELD INSTALLED 1x4 2-LAMP GRID TROFFER-WITH ADVANCE MARK 10 TWO-WIRE ST8-14-2-32-G-FS-Al2- K4 DIMMING BALLAST AND INTERNAL DISCONNECT SWITCH-EM 1400 CODES BIA EU W/ADVMK 10&BEST USHIO(2)F32T8/830 120V 68W 0 LUMEN BATTERY-ELECTRICAL ROOM BAL1400 FIELD INSTALLED 4FT 2 LAMP WET LOCATION SURFACE FLUORESCENT-WALK-IN BEGHELLI 1 H K5 FREEZER&COOLER 254W-120/277 USHIO(2)F54T5H0/830 120V 112W 3 L1 7"DW.X12"H GLASS OPEN ENDED PENDANT WITH BLACK CORD; MODA LIGHTING CUSTOM MADE LED LONG FILAMENT BULB 120V 13W 8 FINISH,CRIMSON RED-DINING AREA L2 7"DIA.X12 GLASS OPEN ENDED PENDANT WITH BLACK CORD; MODA LIGHTING CUSTOM MADE LED LONG FILAMENT BULB 120V 13W 6 FINISH,TEAL GLASS-DINING AREA L3 6"DLA, BAND LIGHT LED PENDANT WITH RED ACCENT B LIGHT CIELO LED FLAT PANEL 120V 13W 17 AND COPPER CORD;FINISH,WHITE/TOMATO/COPPER CORD- DINING AREA L4 54"W 3-ly BLADE PITCH,6-12 DOWNROD CEILING FAN;FINISH, IGHTING DIRECT CRAFTMADE- _ 120V - 0 BRUSHED POLISHED NICKEL-ENTRY MND54BK3 D L5 5.25"DIA.X4'b BLACK WALL BOOTH MOUNTED LIGHT,FINISH; ROW STUDIO MN-4P.MONOCLE LED FLAT LENS 100-120V 120V 8.7W 0 BLACK-DINING AREA INTEGRAL DRIVER O W3 BATHR11HOOM OVERLID 12"MIRROR 11"PROVIDED WALL SCONCE WITH SATIN CHROME AFX BBV241800L3OD1SA 1800L 3000K INTEGRAL LEDS 120V 17W 2 .Fire Alarm Plans shall be sent the State Fire Marshal Office and designed in accordance with Current NFPA 72 standards.Plans shall be in O W4 BATHROOM 45"SIDE WALL SCONCE WITH SATIN CHROME FINISH LED AFX BBV362700L3OD1SA 2700L 3000K INTEGRAL LEDS 120V 25W 2 120V.PROVIDED WITH TWO WIRE DIMMABLE LED DRIVER. 1/8 inch scale and may be sent electronically to verl.jarviel@doi.idaho.gov.Hard copies are no longer accepted. Idaho State Fire Marshal DUAL MR16 STRAIGHT SIGNAGE LIGHTING(REMOTE DRIVER)WITH A L-716-BK-12-GL-11 SORA4 VIVD2 SM16-07-36D- �i55\OSTENIAL�h/ 1820 E.17th Street,Suite#220 �---" L8 MOUNTED AND 24"STEM EXTENSION;FINISH,POWDER COAT HEI LIFE,INC. LA-3;W/(2)HL-360 120V (2)7.5W 0 BLACK-EXPO AREA 927-03(36 DEGREE FLOOD 00943) N( ti Idaho Falls,Idaho 83404 VIRGO+LS6 LED MODULE-3,000K,6 LEDS PER MODULE-MOUNTED ON _ THE UNDERSIDE OF THE PASS SHELF ON THE ASSEMBLY SIDE OF THE a 9316 p KITCHEN AREA.PROVIDE(1)LMPS-350 TRANSFORMER TO POWER UP TO VI-V6-6-30K 3000K INTEGRAL LEDS 10V 2.4W An electrical permit shall be obtained through the Twin Falls Building Department. (SCALED X2) (15)LS6 MODULES.PROVIDE(1)LMPS DIMMER CONTROLLER. N� O (SEE DETAIL#3, LS6 (1)LIMPS DIMMER CONTROLLER-FOR USE WITH LS6 FIXTURES ONLY. HEICO LMPS-DIMMER NA 0-IOV NA 9�oF�OPy� SHEET E410 FOR CONTROLLER-1004.69 9��+'ELL R OP DEVICE MOUNTING (1)LMPS-350 120V/10V 35VA OUTPUT TRANSFORMER,(WITH LINE LMPS-120-35-1 NA 120V TO 35W /5/1 LOCATIONS.) CORD). FORMER MAX MINI MR16 120V GU-24 WHITE TRACK HEAD WITH 18"WAND& R715-WH R40-WH 110 M2S MONOPOINT WITH WHITE FINISH-MOUNTED IN TECTUM CENNG TO JUNO TW18WH / SM16GA-07-10D-927-03 120V 7.5W 0 HIGHLIGHT ARTWORK&DINING AREA GENERAL ILLUMINATION. 10 DEGREE SPOT 00111 EM1 SMALL WHITE EMERGENCY BUG EYE-250 LUMEN OUTPUT- BEST RMR16W (2)7W MR16 HALOGEN LAMPS 120V 14W 3 J RESTROOMS,EXPO AREA&SHALLOW HARD LID AREAS IN DINING INCLUDED 0 URGE WHITE CEILING MOUNTED EMERGENCY FIXTURE-1000 TA-24W-SE- 27W FLORESCENT LAMP EM2 LUMEN OUTPUT-HIGH CEILINGS IN DINING AREA ONLY BEGHELLI UNV-AT-NM INCLUDED 120V 27W 4 W 4"TRACK LIGHTING;MR16 12V TRACK LIGHTING LOW VOLTAGE WITH E-GKOMC2-K; w cli T2 BUCK FINISH RATED FOR WET LOCATION-MOUNTED IN TRELLIS FOR ECONOLIGHT E-GT4A-K; LED LAMPS,INTEGRAL DRIVER 120V 7.5W 0 OUTDOOR DINING AREA F_GC1n7vF X1 RECESSED SINGLE FACE EDGE-LIT EMERGENCY EXIT W/BATTERY BACKUP BEST RELZXTEIGCAEM-SDT INTEGRAL LEDS 120V 3.8W 3 w &GREEN LETTERS ON CLEAR PANEL-FOR USE IN INNING AREA. RECESSED SINGLE FACE EDGE-LIT EMERGENCY EXIT W/BATTERY BACKUP BEST W III.- M ~ X1A &GREEN LETTERS ON CLEAR PANEL-FOR USE IN DINNING AREA. RELZXTE2GCAEM-SDT INTEGRAL LEDS 120V 3.SW 1 oD Y LU o W X2 WHITE EMERGENCY EXIT SIGN WITH GREEN LETTERS-BON. BEST EZXTEU2GWEM-SDT INTEGRAL LEDS 120V 3.8W I22 X2A WHITE DIRECTIONAL EMERGENCY EXIT SIGN WITH GREEN LETTERS BEST EZXTEU2GWEM-SDT INTEGRAL LEDS 120V 3.8W 0 =Z Q BOH. _ EXTERIOR WET LOCATION EMERGENCY LIGHT IN DARK BRONZE w> J X3 FINISH.FOR USE OVER EXTERIOR EGRESS DOORS BEST DBEL-BR-SDT INTEGRAL LEDS 120V 10W 2 Z n Z ® PL1 POST MOUNTED PATIO LIGHT. MOUNTED ON TOP OF PRE-FAB SPECTRA WW-DB 3"POLE ~U a� m POST 0 10'-0"AFF(POST MODEL PR3-10-125-DB) INTEGRAL LEDS 120V 20.9W 0 MOUNT NOTE:ALL EXIT&EMERGENCY LIGHTING FIXTURES SHALL BE EQUIPPED WITH MINIMUM 90 MINUTES OF EMERGENCY BATTERY BACKUP&COMPLY WITH ALL LOCAL&NATIONAL CODES. NOTE:SEE THE LIGHTING FINISH KEY FOR MORE INFORMATION. J LIGHTING VENDOR HEATHER PURDIE LU 0 wbPRO MANAGER o Z WI EDENBACH BROWN I THE ULTIMATE LIGHTING SOURCE W I E D E N B A C H T:781.619.6077 I F:914.846.1371 co BROWN EMAIL:heatheryurdie@wblighLmm w H >G o N 3 NLO J E201 POWER KEYED NOTES GENERAL POWER NOTES _______________ __---_____---_____---_____---__ i Cu ai O CONTRACTOR TO PROVIDE AND INSTALL 1-1/4"MUD RINGS ON 18 PROVIDE 30A,208V, 10,NEMA 3R DISCONNECT SWITCH AT ICE 1. VERIFY ELECTRICAL REQUIREMENTS FOR ALL SPECIAL EQUIPMENT PRIOR TO ANY WORK BEING PERFORMED.PROVIDE E LA EXPO SIDE OF HALF WALL FOR ALL POWER AND DATA OUTLETS. MAKER CONDENSER ON ROOF FOR SERVICING EQUIPMENT,AND ISOLATED GROUND WIRE PER EQUIPMENT MANUFACTURER'S INSTALLATION REQUIREMENTS.PROVIDE CONDUIT FOR e EXTEND FEEDERS FROM INDOOR UNIT TO CONDENSER ON ROOF. cu O2 POWER FOR PASS SHELF LIGHTING TRANSFORMER.CONTRACTOR TO MECHANICAL CONTROLS AS MAY BE REQUIRED BY CODE.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH o PROVIDE(1)GFCI DUPLEX RECEPTACLE 21"AFF(MOUNTED 19 PROVIDE&MAINTAIN REQUIRED CLEARANCE FOR ELECTRICAL MECHANICAL CONTRACTOR AS TO LOCATION OF A/C UNITS&EXHAUST FANS. V PANELS. SIDEWAYS)&(1)SINGLE GANG RING BOX MOUNTED NEXT TO 2. ALL POWER CIRCUITS SHALL BE INSTALLED BY AN ELECTRICIAN LICENSED IN THE JURISDICTION OF THE PROJECT. RECEPTACLE.PROVIDE A SECOND,SINGLE GANG RING BOX r ME 20 EXTEND CONDUIT&CONDUCTORS FOR EXHAUST FANS&MAKE-UP MOUNTED SIDEWAYS BELOW PASS SHELF AT 45"AFF.SEE TYPICAL OAIR UNIT FROM HOOD CONTROL PANEL TO EQUIPMENT ON ROOF. 3. E.C.TO SIZE&PROVIDE ALL ELECTRICAL JUNCTION BOXES,PULL BOXES&DEVICE BOXES. N 81•OE _i__ B-3 5 'o Vw LL ASSEMBLY PASS SHELF LIGHTING DETAIL#3,SHEET E400 FOR SEE SHEET MEP100 FOR MORE INFORMATION.COORDINATE EXACT nai v B-1 ADDITIONAL INFORMATION. EQUIPMENT LOCATION WITH MECHANICAL CONTRACTOR. 4. E.C.TO PROVIDE ALL NECESSARY POWER AND FINAL CONNECTIONS TO ROOF MOUNTED EQUIPMENT.COORDINATE a 3 iv J 9 4 �c ROOF PENETRATION REQUIREMENTS WITH LANDLORD. O3 G.C.TO ENSURE ALL PENETRATIONS OF WALK-IN BOX ARE SEALED. 2,E.C.TO WIRE FREEZER DRAIN LINE,DOOR HEATER&RUN a �- 0000 �� ROOF PENETRATIONS APPROVED BY BUILDING OWNER FOR CONTROL WIRES FOR ELECTRIC DEFROST TIMER.P.C.TO WRAP 5. E.C.SHALL PROVIDE PHENOLIC LABELS INDICATING ELECTRICAL PANEL&CIRCUIT NUMBER(S)FOR ALL F_ F._.7 C-42 15 HALLWAY® o„ WARRANTY ISSUES.WALK-IN BOX TO BE SEALED TO ADJACENT FREEZER DRAIN WITH HEAT STRIP.E.C.PROVIDE 120V.CONNECTION RECEPTACLES,JUNCTION BOXES(USED FOR HARDWIRED CONNECTIONS),EQUIPMENT DISCONNECT SWITCHES,ETC.. a Z AFF ' WALLS&CEILING.IF THE CLEARANCE BETWEEN TOP OF BOX& FOR FREEZER DOOR HEATER,CONDENSATE HEAT TRACE&HEAT FROM WHICH THE DEVICE IS SERVED. N I x a ® �"N� ga CEILING IS GREATER THAN 30",CLOSURE TO CEILING IS NOT AIR RELIEF VENT&COOLER/FREEZER LIGHTING.PROVIDE n� I j \ Q (ON ROOF) mrn NECESSARY. 6. E.C.SHALL INSTALL&CONNECT THE ICE MACHINE.NEITHER THE T.G.C.,NOR ANY SUBCONTRACTOR,IS TO START c� 16.1 18 m KffOF6J gF CONNECTIONS PER MANUFACTURER'S REQUIREMENTS&PER N.E.C. �. �I 300.7.CIRCUIT BREAKER SHALL BE LABELED&PROVIDE POSITIVE EITHER ICE MACHINE.A MANUFACTURER'S REPRESENTATIVE WILL INITIATE THE START UP OF ICE MACHINE. ® MEN ®APPROXIMATE LOCATION OF PHONE BLOCK&PATCH PANEL FOR LOCKOUT IN THE"OFF"POSITION.CONTRACTOR TO COORDINATE J #12 FF 107 INCOMING TELEPHONE SERVICE.FIELD VERIFY TELEPHONE SERVICE WITH FREEZER MANUFACTURER TO PROVIDE WARNING LABELS& 7. E.C.SHALL RESPONSIBLE TO FURNISH&INSTALL CORDS&PLUGS AS REQUIRED FOR THE ICE MACHINE. w A_23 m EQUIPMENT REQUIREMENTS,LOCATION&MOUNTING HEIGHT WITH _ m APPROPRIATELY MARK ELECTRIC HEAT TRACE IN ACCORDANCE WITH rn 2 B-27,29 - _ OWNER AN PROVIDE A DEDICATED RECEPTACLE FOR N.E.C.ARTICLE 427.13. & WHEN MAIN ELECTRICAL SERVICE IS PROVIDED BY THE LANDLORD,HIS OBLIGATIONS TERMINATE AT THE TENANT ni J +78 ALL 6 a r m m a i TELEPHONE EQUIPMENT&ALL OTHER DEVICES REQUIRED FOR SPACE.ALL PANELS,FEEDERS,ETC.REQUIRED FOR THE CONSTRUCTION OF THIS PROJECT SHALL BE FURNISHED A = TELEPHONE SERVICE EQUIPMENT INSTALLATION.PROVIDE &INSTALLED BY THE E.C. m 15 z m m 22 FREEZER EVAPORATOR-20A.,2P.,208V.,WEATHERPROOF MOTOR L7 FIRE-TREATED PLYWOOD BACKING AS NEEDED. O - B-11 m m W RATED DISCONNECT SWITCH.INSTALL PER N.E.C.430.102&300.7, 9 STARTER&RELATED WIRING SHALL BE FURNISHED&INSTALLED BY E.C.OVERLOAD LIMITS SHALL BE INSTALLED L J PROVIDE CONNECTION TO CONDENSER PER MANUFACTURER'S -- --- v A-18 m J N E, O5 SEE DETAIL k2,THIS SHEET,OFFICE RECEPTACLE DETAIL,FOR PER GIVEN NAMEPLATE DATA ON EQUIPMENT.STARTERS SHALL BE INSTALLED AS PER REQUIREMENTS. -'_-` \ f 12 RR REQUIREMENTS.FREEZER EVAPORATOR SHALL BE CIRCUITED FROM +60 AFF BACK WALL ECEPTACLE LOCATION&CIRCUIT CALL OUTS. N FREEZER CONDENSER(ON ROOF),SEE SHEETS E300&MEP100 � m 3 w .. 10. E.C.TO PROVIDE ELECTRICAL OUTLET FIRE PROTECTION"PUTTY PAD"FOR ALL RECEPTACLES IN RATED WALL AS ON ROOF WOMEN FOR CIRCUIT INFORMATION. ( ) MOUNT RECEPTACLE TURNED HORIZONTAL. MANUFACTUREDY PFP PARTNERS.APPLY T X A INSTRUCTEDY MFR.T PR VI RATING T M Ef O BL 0 BO ES S B 0 PROVIDE G O E _- i 3 g3 COOLER EVAPORATOR-20A., 1P., 120V.,WEATHERPROOF MOTOR RATING OF CORRESPONDING WALL. '�_$ PO 0 7 46.2 46 8 B 8 AFF ® J '^ a O7 PROVIDE JUNCTION BOX FOR COMMUNICATION WIRING FROM REMOTE RATED DISCONNECT SWITCH.INSTALL PER N.E.C.430.102&300.7. - " -T-- +24 F CONDENSING UNIT ON ROOF.MAKE ALL FINAL CONNECTIONS.SEE 11. WHERE PORTIONS OF A CABLE RACEWAY OR SLEEVE ARE KNOWN TO BE SUBJECTED TO DIFFERENT TEMPERATURES SHEET MEP100 FOR MORE INFORMATION. PROVIDE CONNECTIONS TO CONDENSER PER MANUFACTURER'S &WHERE CONDENSATION IS KNOWN TO AN ISSUE,AS IN COLD STORAGE AREAS OF BUILDINGS OR WHERE - 30.2 A-iW J J J J A-35 REQUIREMENTS.COOLER EVAPORATOR SHALL BE CIRCUITED FROM PASSING FROM THE INTERIOR TO THE EXTERIOR OF A BUILDING,THE RACEWAY OR SLEEVE SHALL BE FILLED WITH B-9 p,� +24"AFF 46.1 8 COOLER CONDENSER ON ROOF,SEE SHEETS E300&MEP100 "10118 8 +2 AFF ®E.C.TO STUB POWER AT WALL&BRANCH THRU CABINET TO ( ) AN APPROVED MATERIAL TO PREVENT THE CIRCULATION OF WARM AIR TO COLDER SECTION OF THE RACEWAY OR 4� C-ig CONNECTION POINTS.E.C.TO PROVIDE I.G.RECEPTACLES INSIDE FOR CIRCUIT INFORMATION. 1 LG. 45 8 SLEEVE PER N.E.C.300.7(A). A-373 41 ® 11 +24"AFF CABINETS FOR POND EQUIPMENT.E.C.TO PROVIDE RECEPTACLES 31 +21,"AFF 45"AFF J J ®/ FOR SODA&TEA EQUIPMENT.E.C.TO PROVIDE JUNCTION BOXES ®CONTRACTOR K PROVIDE JUNCTION BOX(FIELD VERIFY MOUNTING 12, VERIFY EXACT LOCATION,MOUNTING HEIGHT&ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT PROVIDED BY 30., C-1214 i6� i 2; 1 -31 9 FOR HARDWIRE CONNECTION TO F.O.H.ICE MAKER AND REMOTE HEIGHT)&MAKE ALL FINAL CONNECTIONS TO GAS WATER HEATER OTHERS(INCLUDING HVAC EQUIPMENT)PRIOR TO ROUGH-IN&PROVIDE ALL REQUIRED FUSIBLE SWITCHES, C-182022 -c +24"AFF 52.3 10 1 CONDENSER INTERCONNECTION WIRING.OPENINGS FOR APPLIANCE PER THE MANUFACTURER'S INSTRUCTIONS.ALL WORK SHALL BE IN TRANSFORMERS,STARTERS,ETC.NECESSARY FOR PROPER OPERATION OF EQUIPMENT. GS N B-20 I.G_ -31 BUBBLER® 15B_13 iY-Y CORDS OR WATER CONNECTIONS TO BE PROVIDED BY MILLWORK ACCORDANCE WITH ALL NATIONAL&LOCAL CODES.CIRCUIT AS 30.3 A-2 4 6 N 1 i +96 AFF 1 J FUTURE BUBBLER® / 1 CONTRACTOR.BRACE CONDUIT&JUNCTION BOX&MAKE FINAL INDICATED ON PLANS.PROVIDE A 120V/1P TOGGLE SWITCH 13. ALL RECEPTACLES IN PUBLIC SPACES SHALL BE LISTED TAMPER-RESISTANT. C-26 1 A ,ON TO EQUIPMENT.NOTE:ALL DEVICES SHALL BE (MOUNTED IN AN ACCESSIBLE LOCATION)FOR SERVICING `� o +18 AFF �4 -26 6 IY-7 1 MOUNTED IN ACCESSIBLE LOCATIONS. EQUIPMENT. 14. ALL LOW VOLTAGE WIRING IN CEILING PLENUM(INCLUDING TELEPHONE.DATA,ALARM&TEMP.CONTROL WIRING) a r �34 +18 AFF SHALL BE UL LISTED TEFLON PLENUM CABLE. +60 34 52!1 ib v �� C-11,p1-p3 TO PATIO HEATER O9 NEW DIGITAL PREVIEW BOARD.PROVIDE(1)DUPLEX RECEPTACLE& 25 CIRCULATION PUMP WITH INTEGRATED TIMECLOCK FOR PUMP iLG. )AN LOCATION (1)JUNCTION BOX FOR DATA MOUNTED AT HEIGHT INDICATED. CONTROL.CIRCULATION PUMP EQUIPPED WITH CORD AND PLUG, 15, ALL OUTLETS&ROUGH-INS SHOWN RELATE TO FOOD SERVICE FIXTURES&EQUIPMENT ONLY.SEE < \ Or1 _ w_ram I,G. - 522 PROVIDE CONDUIT WITH PULL STRING FROM JUNCTION BOX TO FIELD VERIFY EXACT MOUNTING HEIGHT/LOCATION OF DUPLEX ARCHITECTURAL/FOOD SERVICE EQUIP PLANS FOR ADDITIONAL ELECTRICAL REQUIREMENTS. ACCESSIBLE CEILING(SEE"DATA RECEPTACLE REQUIREMENTS"BOX RECEPTACLE WITH PLUMBING INSTALLER PRIOR ROUGH-IN. B_2q NOTE,THIS SHEET FOR ADDITIONAL INFORMATION).FIELD VERIFY 16. THIS ELECTRICAL PLAN IS INTENDED TO SHOW LAYOUT&LOAD REQUIREMENTS.VERIFY EXACT LOCATIONS WITH ;;; 134. A 2 +4 AFF 52.1 1 ' EXACT MOUNTING LOCATIONS WITH EQUIPMENT BEING INSTALLED& ©EACH GAS PATIO HEATER WITH ELECTRIC GAS VALVE SHALL ELECTRICAL ROUGH-IN&OTHER DISCIPLINES. ---1 +18 FF LG. COORDINATE INSTALLATION WITH OWNER. CONTROLLED BY INDIVIDUAL WALL SWITCH FOR ON/OFF CONTROL. 7 8 26 A g4 �� SEE KEYED NOTE#26 THIS SHEET&PATIO HEATER DETAIL, 17. SEE FOOD SERVICE PLANS,SHEET FS205 FOR KITCHEN EQUIPMENT SCHEDULE. -f 1 O CONTRACTOR TO ROUGH-IN FOR DATA RECEPTACLE(S)(WHERE DETAIL#1 SHEET E400 FOR MORE INFORMATION.SEE SWITCH BANK LG. B_18 INDICATED ON PLANS).SEE"DATA RECEPTACLE REQUIREMENTS"BOX DETAIL#2,SHEET E200. 1& ALL 15-AMP&20-AMP RECEPTACLES IN KITCHEN AREAS,BATHROOMS,&WITHIN 6'-0"OF SINKS SHALL BE +96 AFF 52.1 10 104 __r _ _ NOTE,THIS SHEET FOR ADDITIONAL INFORMATION. G.EC.I.PROTECTED(PER N.E.C.210.8(B)).PROVIDE G.E.C.I CIRCUIT BREAKERS AS INDICATED IN PANEL C-31 N -- �CONTRACTOR SHALL PROVIDE"SHUNT-TRIP"CIRCUIT BREAKER FOR SCHEDULES,SEE SHEET E300 FOR MORE INFORMATION. "AFF 52.3 10 w B-13 11 SOFT SERVE MACHINE REQUIRES(2)CONNECTIONS EQUIPMENT LOCATED UNDER THE HOOD.EQUIPMENT SHUNT-TRIP N 15 (3-POLE/3-WIRE),(2)DEDICATED CIRCUITS.CONTRACTOR TO SHALL BE WIRED THRU HOOD FIRE SUPPRESSION SYSTEM CONTROL. 19. VERIFY&COORDINATE HEIGHTS&EXACT LOCATIONS FOR ALL ELECTRICAL OUTLETS WITH KITCHEN EQUIPMENT PROVIDE(1)NEMA 6-20R FOR SHAKE SIDE AND(1)NEMA 6-30R SYSTEM CONTROLS SHALL TRIP BREAKERS OFF IN THE EVENT OF A SUPPLIER PRIOR TO ANY WORK. I.G. B-2 52.1 10 FOR THE SOFT SERVE SIDE(EQUIPMENT PROVIDED WITH FACTORY FIRE.SEE PANEL SCHEDULES,SHEET E300 FOR MORE INSTALLED CORDS AND PLUGS).SEE PANEL SCHEDULES,SHEET INFORMATION. 20, E.C.TO VERIFY ALL REQUIREMENTS OF P.O.S STATIONS,PRINTERS,OVERHEAD KITCHEN COMPUTERS,AUDIO/VIDEO G J 67 E300 FOR MORE INFORMATION. EQUIPMENT,MANAGER'S OFFICE COMPUTER STATIONS,NETWORK RACK&TELECOM EQUIPMENT PRIOR TO _ mo 28 E.C.TO PROVIDE A BLANKROUGH-IN. FACE GFCI RECEPTACLE(LEVITON 12 CONTRACTOR TO PROVIDE(1)DUPLEX RECEPTACLE MOUNTED® #7590 OR APPROVED EQUAL),UPSTREAM EAM OF THE RECEPTACLES) L 114"A.F.F.,LOCATED ABOVE OFFICE DOOR FOR CONNECTION TO SERVING EQUIPMENT,FOR GFCI PROTECTION/REMOTE RESET.BUNK 21. POS COMPUTERS,POS PRINTERS,OVERHEAD KITCHEN COMPUTERS,AUDIO/VIDEO EQUIPMENT,MANAGERS OFFICE COMPUTER STATIONS,NETWORK RACK&TELECOM EQUIPMENT ELECTRICAL I.G.RECEPTACLES SHALL BE ORANGE IN SECURITY SYSTEM BY OTHERS. FACE RECEPTACLE SHALL BE MOUNTED IN AN ACCESSIBLE LOCATION IN THE OFFICE.E.C.SHALL PROVIDE A PHENOLIC LABEL INDICATING COLOR.ORANGE RECEPTACLES SHOULD NOT BE USED FOR ANY OTHER OUTLETS. �< LG. m 8-13 13 SEE HOOD DRAWINGS FOR EXHAUST FAN INTERLOCK,HOOD ELECTRICAL PANEL,CIRCUIT NUMBER&EQUIPMENT SERVED(AT m+ bZoi19£ C-4 21 CONTROLS&PREWIRE PACKAGE DETAILS. BOTH THE EQUIPMENT RECEPTACLE(S)&THE BUNK FACE GFCI DINNO ____15_ m oa m 22, CONTRACTOR TO PROVIDE&INSTALL ALL CONDUITS&BOXES FOR ALL AUDIO/VIDEO EQUIPMENT POS DATA " a' M' ' RECEPTACLE)FROM WHICH THE DEVICE IS SERVED. OUTLETS,TELEPHONE OUTLETS,N OUTLETS,CAMERAS OUTLETS,SECURITY SYSTEM OUTLETS,&ANY OTHER LOW a N a J n a � Igo 14 E.C.TO PROVIDE RECEPTACLE AT HEIGHT INDICATED FOR OWNER VOLTAGE SYSTEM OUTLETS AS REQUIRED.COORDINATE WITH SYSTEM VENDERS FOR ALL REQUIREMENTS. 3 N PROVIDED"BUG-LIGHT". 29 'OEC IN PROVIDE DUPLEX RECEPTACLE AND DATA OUTLET FLUSH IN 23. UNLESS OTHERWISE NOTED,ALL ELECTRICAL WORK FOR FABRICATED FOOD SERVICE EQUIPMENT SHALL BE CEILING FOR CONNECTION OF MONITOR. VERIFY LOCATION IN THE 15 FINAL LOCATION OF OUTLETS IN DINING SHALL BE DETERMINED BY FIELD WITH KITCHEN EQUIPMENT SUPPLIER PRIOR TO ANY COMPLETELY WIRED BY KITCHEN EQUIPMENT ELECTRICAL WORK FROM PANEL BOARDS TO BE BY THE ELECTRICAL DIVISION. DIVISION TO A JUNCTION BOX OR PULL BOX MOUNTED ON THE o ¢ OWNER.SEE SPEC FOR DEVICE/COVER PLATE COLOR,SHEET E100. ROUGH-IN, EQUIPMENT IN AN ACCESSIBLE LOCATION.FINAL CONNECTIONS TO EQUIPMENT JUNCTION BOX OR PULL BOX&ALL a �q 16 PROVIDE RECEPTACLE ABOVE STOREFRONT WINDOW(TYPICAL- 30 HOOD IS PRE-WIRED FROM ITEM#30.2. 24. FINAL CONNECTIONS TO ALL EQUIPMENT TO BE BY ELECTRICAL DIVISION,INCLUDING MATERIALS. F N MOUNT RECEPTACLE 6"ABOVE WINDOW IN HIGH CEILING AREAS& '-'"•' SXpf\AL F� FLUSH MOUNTED CEILING RECEPTACLE IN SOFFIT AREAS).SEE SPEC 25. E.C.TO CONFIRM UTILITY REQUIREMENTS FOR ALL OWNER/VENDOR/EXISTING EQUIPMENT PRIOR TO ROUGH-IN. E OFRC�,F C FOR DEVICE/COVER PLATE COLOR,SHEET E100. �- -��-------9 42w18 '6- i �► I 26. ELECTRICAL DIVISION TO FURNISH&INSTALL THE FOLLOWING: 1 17 PROVIDE CONNECTION TO N.E.C.CUSS 2, 120V/24V TRANSFORMER i ® 5 28 53 G 9 a ve p FOR PATIO HEATERS.TRANSFORMER SHALL BE SIZED PER 26.A. ALL JUNCTION BOXES,ELECTRICAL OUTLETS,COVER PLATES,SWITCHES,ETC.,NOT BUILT INTO FIXTURES OR ,O +66AFF j Li Li Li Li Li 9016 MANUFACTURER'S SPECIFICATIONS BASED ON THE NUMBER OF EQUIPMENT.ALL OUTLETS,JUNCTION BOXES,COVER PLATES,ETC.,IN DISHROOMS OR AS INDICATED ON i��12 69 J O HEATERS CONNECTED TO SAID TRANSFORMER.TRANSFORMER SIZE SCHEDULES MUST BE VAPOR PROOF. iB-21 ig O (n� :c• SHALL BE DETERMINED IN FIELD&PROVIDED BY THE G.C..(PER THE MANUFACTURER'S SPECIFICATIONS EACH PATIO HEATER 26.8. ALL PLUGS&CORDS AS NOTED ON SCHEDULE.ALL CORDS SHALL BE NEM.A.-RATED&U.L.-APPROVED 541.118 9 PANEL PANEL B-7 PANEL y9lF of P� REQUIRES APPROXIMATELY 20VA).E.C.SHALL MOUNT TRANSFORMER FOR MANUFACTURED AND/OR FABRICATED EQUIPMENT. - - B A B 13_ LL R•�'P ABOVE ACCESSIBLE CEILING(FIELD VERIFY EXACT MOUNTING /5(1 LOCATION)EXTEND 3/4"CONDUIT&WIRE DOWN INSIDE EXTERIOR 26.C. SHUNT-TRIP CIRCUIT BREAKERS/CONTACTORS OR DISCONNECTS FOR FIRE CONTROL SYSTEM TO SHUT-OFF WALL AND INTERCEPT ILL PROVIDED CONDUIT AND WIRE LEADING TO EQUIPMENT BELOW HOODS/VENTILATORS AS REQUIRED BY ADOPTED N.F.P.A.,LOCAL CODES&AS REQUIRED PATIO HEATERS.MAKE ALL FINAL CONNECTIONS PER BY AUTHORITY HAVING JURISDICTION. MANUFACTURER'S SPECIFICATIONS.EACH PATIO HEATER TO BE CONTROLLED BY AN INDIVIDUAL WALL SWITCH.E.C.TO PROVIDE 26.D. DISCONNECTS OR OTHER DEVICES AS REQUIRED BY CODES. WALL SWITCHES FOR PATIO HEATER CONTROL LOCATED IN SWITCH BANK LOCATION AS INDICATED ON SHEET E200.SEE PATIO HEATER 27. WHEN APPLICABLE,ELECTRICAL DIVISION TO PROVIDE CONDUIT&WIRING,INSTALL ELECTRICAL COMPONENTS J DETAIL,DETAIL#1,SHEET E400 FOR MORE INFORMATION&WIRING (PROVIDED BY K.E.C.)&INTER-WIRE BETWEEN THE FOLLOWING: o DIAGRAM. 7- TO \ ch 27.A. REMOTE REFRIGERATION EQUIPMENT TO EVAPORATOR COILS. TO PATIO -------- LJJ HEATER -�i ENTRY QUEUE 27.B. CONTROL PANELS TO WATER-TYPE,VENTILATORS&EXHAUST SUPPLY FANS PER MANUFACTURER'S 1 ,6 ,6 LOCATIONS 26 ® UJ GENERAL NOTES INSTRUCTIONS. n ; ®C-10 ®G-10 58-13 ; ®C-10 iLLI w � 27.C. KITCHEN EXHAUST HOOD/VENTILATORS TO FIRE CONTROL SYSTEM&SHUT-OFFS. III II 1. THE SCOPE OF THE ELECTRICAL WORK SHALL INCLUDE EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT 0 co FURNISHING,INSTALLING&TESTING ALL ELECTRICAL SYSTEMS FOR WRITTEN PERMISSION OF THE LANDLORD. rn LU H- A COMPLETE&FULLY OPERABLE INSTALLATION COMPLY WITH 4 DVR P.RING 6-6 rn 00 LATEST VERSION OF ALL APPLICABLE NATIONAL,STATE&LOCAL 11, ANY PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE 6" _1q ONLY-NO CONDUIT W W CODES. APPROPRIATELY FIRE STOPPED TO RETAIN THE WALL'S RATING.THROUGH PENETRATIONS OF FIRE RATED ASSEMBLIES oo I.G. -------------------- ---------------J m Q U CA 2. LOCATIONS OF EXISTING ELECTRICAL SYSTEM,EQUIPMENT& SHALL BE PROTECTED BY AN APPROVED THROUGH-PENETRATION 620 DEVICES SHALL BE FIELD VERIFIED BY THE TENANT'S GENERAL FIRE-STOP SYSTEM INSTALLED&TESTED IN ACCORDANCE WITH TO PATIO HEATER =Z Q CONTRACTOR(T.G.C.). ASTM 814 OR UL1479 WITH A MINIMUM POSITIVE PRESSURE ! N L___ CONTROLS& - DIFFERENTIAL OF 0.01 INCH OF WATER(2.49Po).THE SYSTEM - -- - --------TRANSFORMER LLl 3. CONTRACTOR SHALL VISIT THE SITE&FAMILIARIZE HIMSELF WITH SHALL HAVE AN T"RATING&A'T"RATING OF NOT LESS THAN LG o wmimu LOCATION Z THE EXISTING CONDITIONS UNDER WHICH HE IS TO PERFORM HIS 1-HOUR,BUT NOT LESS THAN THE REQUIRED RATING OF THE WORK.NO ALLOWANCE WILL BE MADE FOR FAILURE TO COMPLY. WALL PENETRATED. 4. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS&SHALL 12. THE DIRECTIVE,IF ANY,OF THE BUILDING OFFICIAL SHALL TAKE I.G. 8 IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY PRECEDENCE OVER THIS DRAWING REGARDING LOCATION& " oaln eux affix aye / -\ DISCREPANCIES. NUMBER OF EXIT LIGHTS. 1• I I 5. COORDINATE LOCATIONS&ROUTING OF FEEDERS TO 13. ALL L BE SHALL BE COPPER.MINIMUM WIRE&CONDUIT SIZE G / PATIOPANELBOARDS WITH LANDLORD&PROVIDE ALL NECESSARY SHALL BE#12 THHN IN 3/4"CONDUIT OR AS REQUIRED BY 6 APPURTENANCES AS REQUIRED BY LANDLORD&OWNER. CODE. II ® - uu.SxDT. 6. WHERE THE WORD"PROVIDE"IS USED,THE WORD IS UNDERSTOOD TO MEAN"THE ELECTRICAL CONTRACTOR SHALL 14, ALL OPERABLE CONTROLS DEVICES,SHALL HAVE OPERABLE PARTS B-8 _____ - FURNISH,INSTALL&MAKE FINAL CONNECTION TO THE OF THE CONTROLS LOCATED NO HIGHER THAN 48"&NO LOWER ' -11,p1 - o (n EQUIPMENT",UNLESS OTHERWISE NOTED. THAN 18"ABOVE THE FLOOR PER A.D.A.REQUIREMENTS.RESOLVE Lu ANY CONFLICT IN MOUNTING HEIGHT WITH ARCHITECT/OWNER artw-o coHouR�`1 T T o Z 7. REFER TO LANDLORD'S DESIGN SPECIFICATION FOR ADDITIONAL PRIOR TO ROUGH IN. LG. LG.o 1H LG. D� F _ O REQUIREMENTS&INFORMATION. 10 1O LLL 10 MONITOR 15. SUSPENDED ELECTRICAL CONDUITS&OUTLET BOXES ARE TO BE i tj X' X i Z 8. REFER TO ALL DISCIPLINES,INCLUDING ARCHITECTURAL&KITCHEN SUPPORTED FROM THE STRUCTURE USING METAL BRACES. PLANS FOR ADDITIONAL INFORMATION,REQUIREMENTS AND WORK - B_12 Z REQUIRED BY E.C.,PROVIDE ALL LABOR&MATERIAL AS 16. VERIFY MOUNTING HEIGHT OF POWER/DATA FOR MONITORS WITH _ REQU RED. EQUIPMENT SUPPLIER(S)PRIOR TO ROUGH-IN. I.G. I.G. I.G. / \ - - 9. ALL CONDUITS ARE TO BE CONCEALED IN WALLS OR ABOVE 12 O I O I Z CEILINGS.CONDUITS IN EXPOSED CEILING AREAS SHALL EXIT Y-a' WALLS AS CLOSE TO ROOF/FLOOR STRUCTURAL DECK AS t51 6 e \ / \ / J POSSIBLE, 10. ANY EXISTING MATERIALS OR EQUIPMENT NOT TO BE REUSED 17 17 MUST BE COMPLETELY REMOVED&DISPOSED OF PROPERLY.NO -11 JP2 C-11,P3 o o Lu DATA RECEPTACLE REOUIREMENTS p CONTRACTOR TO PROVIDE(1)3/4"CONDUIT WITH PULL STRING, o w A CONDUIT TO EXTEND 6"ABOVE ACCESSIBLE CEILING FROM EACH a OFFICE RECEPTACLE DETAIL o TELEPHONE DATA LINE OR DATACOM DEVICE LOCATION.CONDUIT TO $CALE� 1/2•-1'-0° POWER PLAN HAVE INSULATING BUSHING AT TOP&LOW VOLTAGE BOX MUD RING oll E 210 AT DEVICE.PROVIDE SWEEPING 90'ELBOWS AT ALL TURNS.OWNER N PROVIDED TELEPHONE&DATA/CAT-5 WIRING. SCALE: 1b4•=f-0• W zsasI FIRE ALARM KEYED NOTES FIRE ALARM SYMBOLS ILA 1O PROVIDE FIRE ALARM HORN/STROBE DEVICE. = f�l °z F FIRE ALARM MANUAL PULL STATION U 2O PROVIDE FIRE ALARM STROBE DEVICE. s D FIRE ALARM DUCT/SMOKE DETECTOR c F 3O SEE MEP100 FOR DEVICES MOUNTED IN ROOFTOP EQUIPMENT. F FIRE ALARM STROBE-WALL MOUNTED V d ®PROVIDE FIRE ALARM SMOKE DETECTOR. c 04 FIRE ALARM HORN/STROBE-WALL MOUNTED oo 5O PROVIDE FIRE ALARM MANUAL PULL STATION. OFMM FIRE ALARM MONITORING MODULE ©PROVIDE FIRE ALARM MONITORING MODULE FOR ANSUL SYSTEM. C5, m u 7O PROVIDE FIRE ALARM CONTROL PANEL.VERIFY EXACT LOCATION IN THE FIELD. 3 G N E rcm -mo � z� mo•m -�o mlow fJ E J N 0 3u wm- z"J FIRE ALARM SYSTEM NOTES m a 4 3 O -- -- ---------------------------------- 1. FIRE ALARM SYSTEM SHOWN ON THIS PLAN IS A REFERENCE FOR THE BID PROCESS ONLY. THE FIRE ALARM SYSTEM SHALL BE CONTRACTED WITH THE FIRE ALARM CONTRACTOR FOR DESIGN,PROGRAMMING AND APPROVAL. 2. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY INITIATION DEVICES,ANNUNCIATION DEVICES,POWER SUPPLIES AND CONTROLS AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. r Oi F F 5 3. THE FIRE ALARM CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT THE CONTRACTOR'S SOLE COST AND EXPENSE. 4. PROVIDE WIRING IN ACCORDANCE WITH NEC,NFPA AND AS REQUIRED BY THE LOCAL _ 7"� 00007 AUTHORITY HAVING JURISDICTION. F _ 5. ALL ZONES SHALL BE CLEARLY LABELED ON THE FIRE ALARM CONTROL PANEL. II 6. ONLY FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT SHALL BE USED TO ENSURE COMPATIBILITY WITH THE LANDLORD'S FIRE ALARM SYSTEM. li 7. PROGRAMMING AND TESTING OF THE DEVICES AND SEQUENCE OF OPERATION SHALL BE BY - THE FIRE ALARM CONTRACTOR AT HABIT BURGER'S EXPENSE. I I I 8. EACH FIRE ALARM SYSTEM SHALL BE FINAL TESTED BY THE LOCAL BUILDING AND FIRE MARSHAL AND WITNESSED BY THE LANDLORD'S ON-SITE REPRESENTATIVE. I 9. SEE MEP 100 FOR DEVICES MOUNTED IN ROOFTOP EQUIPMENT. D -----r I F I 4 ----- F O I I I I F F F F F F F F F (TYP OF 4) 2 In 1 F (TYP OF 5) III Y-Y TYP OF 2 F F FM F RAM ---- O i IY-Y � dill[ -------------------------- �_� 7 L—— E_r== III __________________________I — 5 Ct�A1 ---- FN _________ ________2� O(�t/`,�, III fP_d ___________ __ aFIRE ALARM RISER DIAGRAM ;III; n �I gals SCALE: NONE (6) 9FLL R•G/5/1 I L ___________ __ I __ _________ice ______-- :i ill i I I I ----------- --------------- -----------� S �I , fiuji -------------------------- ----------------------- -- rn w u u u W� i u I I li u u I li li I m Q -------------- `rr.....:::..._li-r - �_I�______� I i it II II W II F 7 II _-�_ -w- P'_......._r�I_..._,.,...: ���.......�I II Z Z � - a' I II I I I I II � III II II II � I Li L II I H U m ' II u u n III II II III .II n--- ---n---n--- -- I I II I r u I I -------- I (n I Lu n -----------I ---------T4 ii ilii _�I -�-- �m ————— ———- h J --- — III — --- ------- U o o N W LL 1 FIRE ALARM PLAN a� SCALE: 1/4'4 ENTIRE SHEET ADDED E 211 PANELBOARD DESIGNATION - - - - _'A' - - - _ NEW INSTALL X EXIST LOCATION - _ RELOCATED EXIST - _ PANELBOARD DESIGNATION _________o8w NEW INSTALL X EXIST LOCATION ___ RELOCATED EXIST ___ n _MIii //��QQ �/►/� Q/y� 12012_0_8__VQLTS S PHASE 4 WIRE, SOLID NEUTRAL 6W AMPERE BUS 6W C/1 -20Y_VOLTS 3 PHASE AWIRE, SOLID NEUTRAL 6W AMPERE BUS BOO AMPERE MAIN MLQ - y - - wv AMPERE MAfI�N/�_/�_/�/M�MLO _ 4 fRl1 o y TOP FED ___ BOTTOM FED X FLUSH MTD X SURFACE MTD ___ A.I.C. RATING ________2 cm TOP FED X BOTTOM FED ___ FLUSH MTD X SURFACE MTD ___ A.I.C. RATING �•� LOAD WIRE BRKR BRKR WIRE LOAD CRT ao CRT LOAD WIRE BRKR BRKR WIRE LOAD CRT CRT DESCRIPTION WATTS A B C WATTS DESCRIPTION �c # DESCRIPTION WATTS TYPE SIZE SIZE a A B C a SIZE SIZE TYPE WATTS DESCRIPTION # # TYPE SIZE SIZE a a S s IZE SIZE TYPE # a 1 RTU-1 5088 H 6 50 6648 20 12 H 1560 MUA-1 (30.3) 2 GFCI 1 WATER HEATER (GAS) (9) 744 WH 12 20 1 1704 1 20 12 M 960 P.O.S. ORDER TERMINAL 52 2 GFCI Vo 3 BOBS 6648 1560 4 3 CIRCULATION PUMP 100 M 12 20 1 1060 1 20 12 M 960 P.O.S. ORDER TERMINAL 52 4 GFCI 0 -- - - 5 5088 � 3 6648 3 � � 1560 6 5 SPARE 20 1 1000 1 20 12 M 1000 OFFICE RECEPTACLES 6 � a 7 RTU-2 5532 H 6 60 5532 1 20 - - -- SPARE 8 7 PANEL RECEPTACLE 180 R 12 20 1 1180 1 20 12 M 1000 OFFICE RECEPTACLES 8 9 5532 5532 1 20 - - -- SPARE 10 9 GENERAL RECEPTACLE 360 R 12 20 1 1360 1 20 12 M 1000 OFFICE RECEPTACLES 10 �S LLE o 11 5532 3 6732 1 20 12 M 1200 FIRE SUPPRESSION SYSTEM 31 12 11 RESTROOM/HALL RECEPTACLES 540 R 12 20 1 1540 1 20 12 M 1000 OFFICE RECEPTACLES 12 h PANEL SCHEDULE NOTES 13 FREEZER EVAP.&COND.(3.2)&(3.4) 1682 K 12 20 2182 1 20 12 M 500 HOOD CONTROL PANEL/HOOD LIGHTS(30.2) 14 13 DINING ROOM RECEPTACLES 900 R 12 20 1 1400 1 20 12 M 500 TELEPHONE EQUIP. RECEPT. 14 GFCI 15 BUG-LIGHT RECEPTACLES 360 R 12 20 1 1320 1 20 12 M 960 MONITOR 52.1) 16 GFCI 15 1682 1952 1 20 12 K 270 SODA DISPENSER 46 16 GFCI ( 18 GFCI $___.1. ALL BREAKERS SHALL BE BOLT-ON, UNLESS NOTED OTHERWISE. � ( )17 756 3 1476 1 20 12 K 720 CARBONATOR (12) 18 GFCI 17 RTU RECEPTACLES 720 R 12 201680 1 20 12 M 960 MONITOR (52.1) (D/T)2. CONTRACTOR TO PROVIDE LISTED HANDLE-TIES OR MULTI-POLE 19 COOLER COND. 2 4 19 SMOKE DETECTORS 500 M 12 20 1 1460 1 20 12 M 960 MONITOR 20 GFCIBREAKERS, PER CODE, FOR CIRCUITS WITH SHARED NEUTRALS. ( ) 562 K 12 15 2292 1 20 12 K 1730 ICE TEA EQUIPMENT(D/T)(45) 20 GFCI (52.1)3. CONTRACTOR TO ENSURE LOADS BETWEEN PHASES ON 21 562 2 1030 1 20 12 K 468 U.C. REACH-IN REFRIG. (40) 22 GFCI 21 SECURIT500 M 12 2PANELBOARDS ARE BALANCED TO WITHIN 10%. 23 COOLER COIL (2.2) 216 K 12 15 1 1116 1 20 12 K 900 SHAKE MIXER (39) 24 GFCI 23 SMOKE DUCT DETECTORS 400 M 12 20 1 1360 1 20 12 M 960 MONITOR (52.1) (EXPO) 24 GFCI25 SOFT SERVE(SHAKE SIDE)(41) 2400 K 10 25 3348 1 20 12 K 948 REFRIG.PIZZA PREP TABLE(34) 26 GFCI 25 FIRE ALARM PANEL 500 M 12 20 1 1460 1 20 12 M 960 POS PRINTER (52.2) (EXPO) 26 GFCI �'4. E.C. SHALL PROVIDE LEGIBLE LABELING OF ALL BREAKERS ON oPANELBOARDS (HANDWRITTEN IS NOT ACCEPTABLE). GFCI 27 2400 3348 1 20 12 K 948 REFRIG.PIZZA PREP TABLE(34.2) 28 GFCI 27 ICE MAKER&CONDENSOR(16)&(16.1) 1269 K 12 20 1269 1 20 - - -- SPARE 28 3 w 29 2400 3 3852 1 20 12 K 1452 FRYER BATTERY (23) 30 29 1269 2 1509 1 20 12 M 240 DIGITAL PREVIEW BOARD 30 N i w 31 F.O.H.REMOTE ICE MACHINE COND.UNIT(46.2) 2080 K 10 25 2080 1 - - - -- SHUNT TRIP 32 GFCI 31 BUBBLERS COUNTERTOP GRIDDLE (27.1) 7200 K 1 4 80 1 2260 7200 1 20 12 M 960 SOUNTR TRIP R (52 2) 34 J a PANEL SCHEDULE LEGEND 33 2080 2 3316 1 20 12 K 1236 REFRIG. EQPT. STAND (26) 34 33 GFCI 35 F.O.H. ICE MACHINE (46.1) 127 K 12 15 1 127 1 - - - -- SHUNT TRIP 36 35 7200 7884 W01 6114 REFRIG EQPT. STAND (28) 36 •- INDICATES THIS CIRCUIT TO RECEIVE HANDLE LOCK-ON CLIP 37 EF-1(30.1) 888 H 12 15 888 1 20 - - -- SPARE 38 GFCI 37 7200 3 7200 iK -- SHUNT TRIP 38 TIC- INDICATES THIS CIRCUIT G BE CONTROLLED BY A TIMECLOCK 39 888 888 1 20 - - __ SPARE 40 39 SHUNT TRIP -- - - - 1 900 900 SHAKE MIXER (39) 40 GFCI- REFER TO ONE-LINE DIAGRAM FOR WIRE SIZE TO THIS EQUIPMENT41 888 � � 3 888 1 20 - - -- SPARE 42 41 SPARE -- - - 20 1 270 270 SODA DISPENSER D T 56 42 GFCI ** - COOLER& FREEZER LIGHTS SHALL BE CONTROLLED VIA TIMECLOCK (LIGHTS ONLY). PROVIDE NON-SWICHED HOT FED FOR HEAT TRACE, INSTALL EQUIPMENT GROUND-FAULT 16664 16664 14569 13443 SUB TOTALS L = LTG OR SIGNAGE PROTECTION DEVICE PER N.E.C. 427.22. CIRCUIT BREAKER SHALL FEED THIRD TO PANEL "B" 14569 FEED THIRD TO PANEL "B" R = RECEPTACLE BE A LOCK-OUT/TAG-OUT CIRCUIT BREAKER DEVICE. M = MISCELLANEOUS 13443 CONNECTED LOAD _ 40196 H = H.V.A.C. GFCI- PROVIDE CIRCUIT WITH GFCI RATED CIRCUIT BREAKER. 19055 -- K = KITCHEN 200A SUB FEED BREAKER 18351 200A SUB FEED BREAKER 11032 58689 55634 45314 SUB TOTALS L = LTG OR SIGNAGE PANELBOARD DESIGNATION ________'C'-________ NEW INSTALL X EXIST LOCATION ___ RELOCATED EXIST R = RECEPTACLE ��pp nA CONNECTED LOAD 159637 M = MISCELLANEOUS _�ZO_2SA_VOLTS 3 PHASE AWIRE, SOLID NEUTRAL _225AMPERE BUS _225_AMPFRE MAIN MLO H = H.V.A.C.K = KITCHEN TOP FED ___ BOTTOM FED X FLUSH MTD X SURFACE MTD ___ A.I.C. RATING ________2_z(=_______ CKT DESCRIPTION WATTS LOAD WIRE BRKR` A B C wBRKR WIRE LOAD WATTS DESCRIPTION CRT # TYPE SIZE SIZE d a SIZE SIZE TYPE # T/C 4 1 LOT-KITCHEN FOOD PREP FAPo OFBCE FAI NL 1090 L 12 20 1 1290 1 20 12 M 200 LIGHTING CONTROL 2 T/G 3 LGT-DINING ENTRY ABLE HALLWAY EM NL 415 L 12 20 1 1211 1 20 12 M 796 COOLER/FREEZER LIGHTS/HEAT TRACE 4 **TIC T/C 5 LGT-DECOR LIGHTING 540 L 12 20 1 1740 1 20 12 L 1200 EXTERIOR BUILDING SIGNS 6 T/C 7 LGT-RESTROOM/EM/EF-3&4 495 L 12 20 1 495 1 20 - - -- SPARE 8 9 EXTERIOR EMERGENCY LIGHTING 40 L 12 20 1 580 1 20 12 R 540 WINDOW RECEPTACLE 10 T/C 11 GAS PATIO HEATER CONTROL 60 M 12 20 1 948 15 12 H 888 EF-2 30.1 12 GFCI 13 SOFT SERVE (41) 3000 K 8 35/ 1 1 888 14 15 3000 1 1 1 88 3 888 16 17 3000 3 3660 �12 12 H 660 EF-3 68) 18 GFCI 19 ICE TEA EQUIPMENT (45) 1730 K 12 20 1 2390 660 20 GFCI 21 MONITOR (52.1) 960 M 12 20 1 1620 660 22 23 SPARE -- - - 20 1 468 12 K 468 U.C. REACH-IN REFRIG. (40) 24 GFCI LANDLORDS EXISTING MAIN SWITCHBOARD GFCI 25 ROB PRINTER (D/T) (52.2 960 M 12 20 1 1992 1 201"1 K 1 032 SANDWICH PREP TABLE(64) 26 GFCI 800A BUS )20/2O8V, 30 4W, 22K AC GFCI 27 ROB PRINTER (522) 960 M 12 20 1 1920 1 20 12 M 960 CCTV MONITOR (54) (D/T) 28 GFCI GFCI 29 ROB PRINTER (522) 960 M 12 20 1 1920 1 20 12 M 960 MONITOR (52.1) 30 GFCI �C4i C41STE G�ti LANDLORD'S ELECTRICAL SWITCHBOARD LOCATED ON OUTSIDE OF BUILDING O to TOTAL SERVICE DEMAND LOAD _ _ GFCI 31 D/T WINDOW/AIR CURTAIN 1800 M 12 20 1 9000 80 4 K 7200 COUNTERTOP GRIDDLE (27 32 L Q Cf PANELS PANEL'C'DEMAND LOAD ONLY 33 DRIVE THIRD MENU BOARD 1200 L 8 20 1 8400 I 1 7200 34 a 9316 p CONNECTED DEMAND DEMAND O 35 SPARE - - - 20 1 7200 3 7200 36 N� DESCRIPTION CONNECTED DEMAND DEMAND 37 SPARE -- - - 20 1 -- 1 - - - -- SHUNT TRIP 38 Q TOTAL WATT FACTOR TOTAL WATTS DESCRIPTION TOTAL WATT FACTOR TOTAL WATTS LIGHTING LOAD 4646 1.25 5808 LIGHTING LOAD 4646 L25 5808 39 WORK TOP FREEZER (22) 732 K 12 20 1 732 1 20 - - -- SPARE 40 9��''ELL R pP`O KITCHEN EQUIPMENT 89189 .65 57973 KITCHEN EQUIPMENT 36062 .65 23440 41 SHUNT TRIP -- - - - 1 1500 1 20 12 K 1500 FOG TANK (15) 42 GFCI /5/1 RECEPTACLES 3600 1.0 3600 RECEPTACLES 540 1.0 540 MISC. POWER LOAD 17350 1.0 17350 MISC. POWER LOAD 8280 1.0 8280 M O L = LTG OR SIGNAGE HVAC 31860 1.0 31860 HVAC -- 1.0 -- SUITE 19055 18351 17026 SUB TOTALS R = RECEPTACLE WATER HEATER(GAS) 744 1.0 744 WATER HEATER(GAS) -- 1.0 -- Ti H = HNAECLLANEOUS J CONNECTED LOAD - _54432 K = KITCHEN 0 +25%OF LARGEST MOTOR NEC 13418 +25%OF LARGEST MOTOR NEC 5570 E 610OA G ch � Lu 3P i- BREAKER Lu U3 SERVICE TOTAL 159637 130753 SERVICE TOTAL 1 54432 1 1 43638 Lu W DEMAND AMPS: 130753/(208 x 1.732) = 363.2 DEMAND AMPS: 43638/(208 x 1.732) = 121.2 W M F- VOLTAGE DROP SCHEDULE EXISTING e w Cl Lu 208V/10 BRANCH CIRCUITS. MAXIMUM CIRCUIT LENGTH; GROUND ONE-LINE DIAGRAM KEYED NOTES m Q p vS U' 3% MAX VOLTAGE DROP Oi EXISTING 800A SUPPLY,600A DISTRIBUTION SECTION FOR PROPOSED HABIT BURGER'S J < - WIRE GAUGE TO UTILITY EXISTING SERVICE TENANT SPACE. =Z J TRANSFORMER FEEDERS J #12 #10 #8 #6 #4 #3 ,3 �� O EXISTING ELECTRICAL METER AND C/T FOR HABIT BURGER'S PROPOSED TENANT SPACE. w Z z 8320 N/A N/A 96 152 241 -- `-' CONTRACTOR TO COORDINATE WITH UTILITY COMPANY FOR TENANT CHANGE OVER. U Lo m 7488 N/A N/A 106 169 269 -- O3 EXISTING(2)SETS OF 4 500KCMIL(AL)&1#1 G(CU),IN 3-C(BY LANDLORD,FIELD 6656 N/A N/A 120 190 302 -- HABIT BURGER'S TENANT SPACE VERIFY).EC TO PROVIDE NEW#8(CU)ISOLATED GROUND. LLl 5764 N/A N/A 138 220 ®PROVIDE JUNCTION BOX(SIZE PER CODE)IN SUITABLE LOCATION FOR EXTENSION OF a 4 EXISTING ELECTRICAL 4992 N A 100 160 253 0 EXISTING SERVICE FEEDERS TO PANEL'A'. i a / -- -- STUB-IN BY LANDLORD 0 z 3 4160 N/A 120 192 304 -- -- 5 (FIELD VERIFY LOCATION) O NEW(2)SETS OF 4 500KCMIL(AL)&1#1 G(CU),IN 3-C.EC TO PROVIDE 1#8(CU) _ 3328 94 150 240 -- -- -- ISOLATED GROUND. VOLTAGE DROP SCHEDULE m 2080 151 251 -- -- -- -- _ cUn 120V BRANCH CIRCUITS: MAXIMUM CIRCUIT LENGTH; 3% MAX VOLTAGE DROP 1456 216 - ©PROVIDE 3 250KCMIL(AL)& 1#6(CU)GROUND IN 2"CONDUIT. o= o J O7 PROVIDE ISOLATED GROUND BAR IN NEW PANEL"B". 1#8 COPPER ISOLATED GROUND LLl WIRE GAUGE o Z CONDUCTOR SHALL BE PROVIDED FROM NEW ISOLATED GROUND BAR AND TERMINATE AT #12 #10 #8 #6 #4 #3 VOLTAGE DROP SCHEDULE 6 THE SERVICE EQUIPMENT GROUND BAR LOCATED IN SERVICE PANEL. - � 3840 N/A N/A 69 110 174 220 208V/3m BRANCH CIRCUITS: MAXIMUM CIRCUIT LENGTH; ®LANDLORD SWITCHGEAR EQUIPMENT SHOWN IN ONE-LINE DIAGRAM TAKEN FROM SURVEY& 0 3500 N/A N/A 76 120 191 242 3% MAX VOLTAGE DROP LANDLORD CONSTRUCTION DOCUMENTS.CONTRACTOR TO FIELD VERIFY SERVICE EQUIPMENT Z 3250 N/A N/A 82 130 206 -- WIRE GAUGE &REPORT ANY DISCREPANCIES THAT MAY IMPACT THIS PROJECT TO ENGINEER OF RECORD. Q HABIT BURGER INBff BURGER HABIT BURGER 9 SEE PANEL SCHEDULES,THIS SHEET,FOR MORE INFORMATION. F 3000 N/A N/A 88 140 223 -- #12 I [22 #4 #3 NEW NEW Q PANEL°A" PANEL°B° NEW 2880 N/A 58 92 146 233 -- 14411 N/A 280 -- 600A 600A PANEL°C° a 2500 N/A 66 106 1 69 268 -- 11528 N/A -- -- 120/208V,34, 5 120/208V,30, 225A Q _ 2250 N/A 74 118 187 298 -- 9727 N/A -- -- 4W,42 PoLE, 4W,42 POLE, 1�0/2080LE0 0 z 3 1920 54 87 138 220 -- -- w 8646 N/A -- -- H FEED THR THEQ aPME l44 MLOw1800 58 92 148 234 -- -- a 7205 N/A -- -- LUGS&200A AND ISOLATEDSUB FEED GROUND BARS 1500 70 111 177 281 5764 109 -- -- BREAKER1200 87 139 221 -- -- -- za 3 4323 146 -- -- o NLL"I o1000 105 167 266 -- -- -- m 3602 175 E3Y 0'o wNOTE:700 150 238 -- -- -- -- 2882 219 -- -- 9 7 9 9 a o . = 4� PROVIDE SERVICE EQUIPMENT LABELS PER N.E.C. aI VOLTAGE DROP SCHEDULES al ONE-LINE DIAGR 1 10.15, 110.16, 110.22 & 110.24 (A), (B). SCALE KT.S SCAL B KI a) H /(n� e.I 6c V o V� U N E �m mai � o M go 91111111111111 77. -m mm 2, 'hy 24 VOLT WIRE CONNECTION N TO HEATER TYPICAL ❑ T i p PATIO HEATER WALL SWITCH TYPICAL.PROVIDE EACH PATIO HEATER WITH INDIVIDUAL WALL SWITCH LOCATED AT SWITCH BANK LOCATION. -_ SEE SWITCH BANK,DETAIL#2,SHEET E200 FOR NUMBER OF SWITCHES REQUIRED AND SWITCH DESIGNATION(NUMBER OF SWITCHES SHOWN IN THIS DETAIL FOR REFERENCE ONLY). TO ADDITIONAL PATIO FROM ELECTRICAL H HEATERS(NUMBER OF PANEL,SEE SHEETS 120V 24V PATIO HEATERS SHOWN ON E210&E300 FOR THIS DETAIL ARE FOR CIRCUIT INFORMATION N REFERENCE ONLY) NOTE: N.E.C.CLASS 2 24V TRANSFORMER NUMBER OF PATIO HEATERS SHOWN IN THIS DETAIL DO NOT NECESSARILY REFLECT SUPPLIED BY E.C.(NOTE:SIZE OF THE NUMBER OF PATIO HEATERS BEING INSTALLED AT THIS HABIT BURGER GRILL TRANSFORMER SHALL BE DETERMINED LOCATION.NUMBER OF PATIO HEATERS SHOWN ON THIS DETAIL ARE FOR REFERENCE BY E.C.BASED ON THE NUMBER OF ONLY. REFER TO SHEET E210 FOR QUANTITY&LOCATION OF PATIO HEATERS. PATIO HEATERS CONNECTED TO PATIO "EATER T).SEE R PLAN, TYPICAL PATIO HEATER WIRE DIAGRAM SHEET E21010 FOR INFORMATION.MORE INFORMATION SCALE: N.T.S. ow 18"(457mm) 34 1/2"(86mm)CIA. TOP CLEARANCE REFLECTOR yS\OhAL FN SIDE CLEARANCE a RADIANT EMITTER GRID N 9316 O PILOT LIGHTING HOLE KEEP GREASY HANDS 12" OFF HEATER HEAD 9� �F Q5 (305mm) ❑ 9F�L R' /5/1 1 p 100%SAFETY SHUT-OFF CONTROL 1 HEATER HEAD BASE PROVIDE 24 VOLT WIRE - CONNECTION TO HEATER PER SLIP COLLAR MANUFACTURER'S SPECIFICATIONS J 3"CIA STEEL POST O i 11" W (2820mm) w . t Lu (2362,mm) 1/2"INTERNAL PIPING W O Wch H 00 Y lL in W 84" (2134mm) Q O Cn U NOTE: =Z J E.C.SHALL BE RESPONSIBLE FOR ALL PATIO HEATER FIELD WIRING. - LANDLORD TO PROVIDE CONDUIT TO PATIO HEATERS,COORDINATE ui Z J LOCATION IN THE FIELD.ROUTING OF CONDUIT/CONDUCTORS TO EACH Z u'4 - PATIO HEATER LOCATION,AS WELL AS ALL INTERNAL PATIO HEATER U a� m WIRING SHALL BE COORDINATED IN FIELD WITH PLUMBING CONTRACTOR.PROVIDE ALL NECESSARY DEVICES AND MAKE ALL FINAL CONNECTIONS. i DRILL 7/8"DIA.HOLE THROUGH POST FOR 1/2"ELECTRICAL CONNECTOR. - -m i U.L.OR C.G.A.CERTIFIED WATERPROOF OUTDOOR USE JUNCTION BOX TO BE UNION Z SUPPLIED BY E.C..(VERIFY EXACT UNDERGROUND VAULT BOX(MATERIAL AND LABOR BY TENANT,INSTALLED BY LANDLORD CONTRACTOR) cn MOUNTING LOCATION IN FIELD.) GAS SHUT-OFF VALVE FINISHED GRADE U J LL) COORDINATE ROUTING OF CONDUIT WITH PLUMBING IP LEG,MIN.3"LONG 0 EXTEND CONDUIT TO 24V TRANSFORMER MOUNTED ABOVE CEILING IN HABIT BURGER TENANT SPACE. `a1 SEE SHEET E210 FOR MORE INFORMATION. III-I I1=1I v 3/4"PVC CONDUIT GAS SERVICE PIPE cc � U r o CN a1 PATIO HEATER DETAIL N SCALE: N.T.S. LLl E400 a) H /(n� e.I 6c V o V� TO EXTERIOR LIGHTING LOAD MULTI-POLE LIGHTING CONTACTOR WITH MINIMUM(4) 77. CONTACTS (TYPICAL)& 120V CONTROL COIL(AS NOTED ON PANEL SCHEDULES). m CONTRACTOR TO SUPPLY MINIMUM OF(2)SPARE CONTACTS. - w INTERMATIC#K4121C PHOTOCELL MOUNTED 9 ~m a z ON ROOF FACING NORTH,SEE SHEEP - [7 MEP100 FOR APPROX. MOUNTING LOCATION. m m m mm F J m r~120V N m 3 w i..m C-2C ZOA z in x INTERMATIC#ET1125C DUAL jN 1 J a PROGRAMMABLE TIME CLOC T 2HR OVERRIDE SWITCH,SPRING W i f L OVERRIDE SWITCH SHALL BE LOCAT PC MAIN SWITCH BANK,SEE SHEET E200SWITCH BANK LOC ci TO PANEL MULTI-POLE LIGHTING CONTACTOR WITH MINIMUM(10)CONTACTS(TYPICAL)& LOCAL LIGHTING CONTROL (S1 AS NOTED 120V CONTROL COIL(AS NOTED ON ON LIGHTING PLAN SHEET E200. PANEL SCHEDULES). ASSEMBLY PASS SHELF CR LIGHTING(RECEPTACLE) C-1 (-� T KITCHEN/FOOD PREP/EXPO/OFHCE C-3 DINING ENTRY/TABLE/HALLWAY C_-S I�i i �C�R LIGHTING a C-4 • COOLER/FREEZER LIGHTS o WALK-IN FREEZER HEAT TRACE,DOOR DEFROST,AIR RELIEF VENT(BY-PASS CONTACTOR). - z i C-10 i� WINDOW RECEPTACLES SPARE SPARE- J� AL S I�� i ��QfX,�� SPARE 05 f!\sT/c�CJCi ---J a N 9316 O p EI TYPICAL LIGHTING CONTROL RELAY WIRING DIAGRAM 2 = 9 sca9��of ms U.S. ��Pyw 9FLL F.°/5/1 5 g 5 g 5 g 5 W Lu Ll W O ' �W � Y ( 34.1 34 w - KITCHE EQUIPMENT CALLOUT ~Y LL C W i SHOWN FOR REFERENCE.SEE m Q uj 0 VICE PLANS FOR EXACT UU QUIPMEN LAYOUT" EQUIPMENT =Z J Q 2 INFORMATION wo Z J_ MOUNTED BEHIND EQUIPMENT(TYPICAL) U a� m NOTE: KEYED NOTES - DETAIL SHOWN FOR REFERENCE ONLY. SEE POWER PLAN, SHEET E210 FOR RECEPTACLE & JUNCTION BOX LOCATIONS. 1 CONTRACTOR EXTEND KITCHEN LIGHTING CIRCUIT C-1 (UNSWITCHED) DOWN INSIDE FULL HEIGHT 5 CONTRACTOR TO EPDXY"LS6"LED LIGHTING MODULE TO THE UNDERSIDE OF THE PASS SHELF - SEE FOOD SERVICE DRAWINGS FOR KITCHEN EQUIPMENT LAYOUT O KITCHEN WALL TO PROVIDE POWER TO DUPLEX RECEPTACLE FEEDING PASS SHELF LIGHTING. O(ON THE ASSEMBLY SIDE OF THE FOOD PREP AREA).VERIFY EXACT MOUNTING LOCATIONS WITH HABIT - & INFORMATION. CONTRACTOR TO COORDINATE LOW VOLTAGE REQUIREMENTS & MOUNTING HARDWARE WITH MANUFACTURE. RECEPTACLE SHALL BE CONTROLLED BY LIGHTING TIMECLOCK CONTACTOR(SEE DETAIL$2,THIS SHEET BURGER CONSTRUCTION MANAGER IN FIELD.PROVIDE ALL NECESSARY ATTACHMENTS&BRACING TO FOR MORE INFORMATION).SEE POWER PLAN,SHEEP E210 FOR RECEPTACLE LOCATION&SHEEP E200, MOUNT LIGHTING.INSTALL LIGHTING MODULES PER MANUFACTURES SPECIFICATIONS.SEE LIGHTING VERIFY FIELD ALL MOUNTING HEIGHTS & LOCATIONS OF FOR CIRCUITING.CONTRACTOR SHALL PROVIDE'TIMECLOCK CONTROLLED RECEPTACLE"LABEL ON SCHEDULE,SHEET E201 FOR TRANSFORMER INFORMATION. _ ELECTRICAL DEVICES IN FIELD, ADJUST AS NEEDED. RECEPTACLE COVER PLATE. J ©CONTRACTOR TO SHALL PROVIDE(1-SET)OF#14 AWG,LOWER VOLTAGE TWISTED PAIR CONDUCTORS, a O CONTRACTOR TO PROVIDE(1N GFCI DUPLEX RECEPTACLE 21"AFF(MOUNTED HORIZONTAL)&(1)SINGLE (PER MANUFACTURER'S SPECIFICATIONS)FROM"LMPS"TRANSFORMER&CONNECT TO"LMPS-DIMMER GANG RING BOX MOUNTED NEXT TO RECEPTACLE TO SUPPLY POWER TO PASS SHELF CONTROLLER PROVIDE(1-SET)OF14 AWG LOWER VOLTAGE TWISTED PAIR CONDUCTORS FROM w LIGHTING/TRANSFORMER/DIMMER CONTROLLER.SEE POWER PLAN,SHEET E210 FOR MORE INFORMATION. 0-10V TERMINAL OF"LMPS-DIMMER CONTROLLER",ROUTE CONDUCTOR THRU SINGLE GANG RING BOX Q CONTRACTOR TO PROVIDE'TIMECLOCK CONTROLLED"LABEL ON RECEPTACLE COVER PLATE. (MOUNTED BEHIND EQUIPMENT AT 21"AFF),TO SECOND SINGLE GANG RING BOX(MOUNTED SIDEWAYS BELOW PASS SHELF AT 45"AFF)&FEED CONDUCTOR THRU LED LIGHTING MODULES(PER J O3 CONTRACTOR TO MOUNT"LMPS"TRANSFORMER(WITH PLUG)&"LMPS-DIMMER CONTROLLER"ABOVE MANUFACTURE'S INSTRUCTIONS)TO PROVIDE POWER TO PASS SHELF LIGHTING.PROVIDE ALL Q DUPLEX RECEPTACLE&SINGLE GANG RING BOX TO POWER PASS SHELF LIGHTING.SEE LIGHTING NECESSARY BRACING.CONDUCTOR SHALL BE ONE CONTINUOUS SECTION FROM"LMPS-DIMMER SCHEDULE SHEET E201 FOR TRANSFORMER&DIMMER CONTROLLER INFORMATION. CONTROLLER"O-10V TERMINAL,TO LAST LED LIGHTING MODULE. U ®SINGLE GANG RING BOX MOUNTED SIDEWAYS BELOW PASS SHELF AT 45"AFF.FIELD VERIFY EXACT �, o MOUNTING LOCATION. - � U TYPICAL ASSEMBLY PASS SHELF LIGHTING DETAIL m "' a w � J 3 N � W SCALE NTE E410 SITE PLAN KEYED NOTES r sa N xv ; O1 ILL PROVIDED 1"CONDUIT WITH PULL STRING FROM BASE OF MENU fa BOARD BACK TO DRIVE THRU WINDOW AREA FOR MENU BOARD c: V COMMUNICATION,VIDEO AND DATA LINES.VERIFY STUB UP o LOCATION WITH TENANT'S REPRESENTATIVE PRIOR TO ROUGH-IN. EC b0 TO EXTEND CIRCUIT BACK TO ELECTRICAL PANELS. O TENANT PROVIDED,LANDLORD INSTALLED LOOP DETECTOR IN SLAB AT MENU BOARD. �•C a O3 LANDLORD CONTRACTOR TO MAKE ALL CONNECTIONS FOR PREVIEW/MENU BOARD.TENANT TO PROVIDE(2)#8,(1)#10 00 GROUND IN 1"CONDUIT FROM DRIVE THRU WINDOW BACK TO °^ PANELS.LANDLORD CONTRACTOR TO ROUTE CIRCUIT THROUGH SWITCH IN DRIVE UP WINDOW AREA.VERIFY REQUIREMENTS WITH EQUIPMENT SUPPLIER. ®LANLORD CONTRACTOR TO MAKE ALL CONNECTIONS FOR DIRECTIONAL SIGNAGE.TENANT TO PROVIDE(2)#8,(1)#10 o m E GROUND IN 1"CONDUIT FROM DRIVE THRU WINDOW BACK TO E. PANELS.LANDLORD CONTRACTOR TO ROUTE CIRCUIT THROUGH SWITCH IN DRIVE UP WINDOW AREA.VERIFY REQUIREMENTS WITH z EQUIPMENT SUPPLIER. z o m m m ED -m mm O N m 77 L i' J of x�3 a 0 J 7—L -- 8 (PARTIAL) 0 0 . a C-3 (PARTIAL) Ell SWITCH FO EXT HABIT BURGER SPACE BOARD AN �4RE SIGNAGE A 4$ yS\OhAL FN O CCL a 9316 p y� O 9�OF�OPSki 9....9FLL F-G/5/1 J 0 w cli w rn w F j co Y w o W m¢ o vi U In 2 z C n t w Z (PARTIAL) =z z - a J CL H Cf) 3 � � J al 1 ELECTRICAL SITE PLAN N °' w p` "�'�-°' E500