HomeMy WebLinkAbout25-2858 801 Pole Line Rd W-City Approved Job Site Plans 1''INYF�[.l fi TWIN MIS� City of Twin Falls ifqQ 1" �� �r a,�♦ 0 General Inspection Notes Q� ese NOTE: This is not a complete list and is not inclusive of all construction methods, materials or practices. These checklists are intended to serve as a guide for the items that cause the most issues during inspections and promote consistency in the application of the codes and standard practices. Compliance with all the provisions of applicable codes shall be required. The information in the checklists is not, or was it ever intended to be, all inclusive. It does not include all code or individual plan requirements. It is intended to reflect local policies, procedures practices within the City of Twin Falls. These checklists do not waive any specific code requirements not listed or allow for the decrease in the requirements of an engineered design. It also does not add requirements where the minimum of the code has been met. This page and all approved plans, associated documents, revisions and changes to the plans must be maintained on site and available for review at all times. FIRE BUILDING FINAL INSPECTION INFORMATION Fire Alarm Inspection: Footing/Foundation Inspection: COMMERCIAL OCCUPANCY * Fire alarm plans must be approved by the State Fire Marshal's office or if applicable the Twin Falls Fire Marshal *All re-bar must be tied in place at time of inspection. prior to installation and inspection. *All hold down anchors installed properly. Final inspections are required by multiple City Departments/Inspectors prior to getting your Certificate of Occupancy. * Fire alarm system must be wired to call out from a land line, or with a cell dialer. (Voice over IP is not allowed). Shear Inspection: Fire alarm system must be live and capable of calling the Twin Falls Dispatch Center on the day of testing. Make sure to have the approved set of plans and inspection card on site for all inspections. *All hold downs must be installed per approved plans and manufacturers installation guide. Fire Sprinkler Inspection: * Fasteners should not be overdriven and shiners should be removed and/or replaced. If you have Special Inspections: Once the required special inspections have been completed a final report needs to be submitted to the * Fire sprinkler plans must be approved by the State Fire Marshal's office prior to installation and inspection. Underground fire * Install the correct type of fastener at the correct spacing. building department certifying corrections of any discrepancies noted in the special inspection reports.This final report can be sprinkler line must be inspected by the Twin Falls Fire Department prior to being covered. submitted anytime before requesting occupancy. * Pipe or hose used for flushing the underground sprinkler line must be secure, incapable of movement,and is deemed safe Framing Inspection: by the inspector. Required Site Work inspections may be requested and completed as the work is done or as required by the specific department by * Rough to cover inspection and hydro testing must be completed before covering or tenting the above ground fire sprinkler *Accessibility standards are in compliance.(ICC A117.1-2009) contacting the following: system. * Required load paths to footing for all load points are installed. Planning and Zoning(parking and landscaping)---Planner-208-735-7270 or Office-208-735-7267 *Stair rise and treads must meet code requirements. Engineering(Retention, curb,gutter,sidewalk, drive approaches)--- Lab inspection line 208-735-3446 Kitchen Hood Inspections: *Min rise 4", Max rise 7", Max tread 11" Street Department(road cuts)---Office-208-736-2226 * Fire suppression system must be installed and ready for trip test(trip link, balloons, etc.) prior to inspection. *Min nosing is 3/4", Max nosing is 1 1/4"and cannot differ in length by more than 3/8" * Kitchen hood must be wired to initiate the fire alarm upon activation of the fire suppression system. (The only exception to Provide required up-lift protection for all trusses. When you are ready for any Fire Department inspections please call(extinguishers,fire/alarm/sprinkler systems): this is if the building does not require a fire alarm to be installed) - Fire Inspection Line-208-735-7338 *All electrical outlets, lighting,and appliances under the kitchen hood must shut down upon activation of the fire suppression Final Inspection: When you are ready for a building final inspection on the structure: system. * Landings to meet minimum code requirements. Make sure you have the final inspections on the plumbing,electrical,and mechanical work. * Main gas valve must be installed and must shut down upon activation of the fire suppression system. (Doors 1010.1.6, Ramps 1012.6,Stairs 1011.6) Call the building inspection line 208-735-7333. * Exhaust fan must be capable of running continuously upon activation of the fire suppression system. *Accessibility Standards are in compliance.(ICC A117.1-2009) All departments will be notified by this office to go do their final inspection. * Make up air must be capable of running continuously upon activation of the fire suppression system. * Egress door sign-age is posted and correct verbiage is used. Final Inspection: *"DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED" If there is an elevator in the building please contact the Division of Building Safety at the following link for any permits/inspections: *Correct hardware has been installed on all doors. http://dbs.idaho.gov/programs/industrial/fagEL.html *Address must be posted as outlined on the approved set of plans or previously approved by the Twin Falls Fire Marshal. *Panic hardware is installed where required. *Accessible hardware is installed where required. Once ALL the departments have signed the Certificate of Occupancy the Building Official will sign,and then it will be ready to be picked * Handrails shall be installed where required. up or emailed. ENGINEERING *Stairways shall have handrails on each side. To streamline and eliminate confusion regarding engineering department commercial permit inspections,the following will *All racking and shelving to be in place. If you need a Temporary Certificate of Occupancy there is a $1,000 refundable deposit required.All departments are required to sign need to be inspected prior to signing the Certificate of Occupancy.All inspections will be completed using the City of Twin *All Exit signs are field verified.(must be visible-nothing can block the line of sight) and give a list of outstanding issues. Once the temporary is all signed and the list made you will need to come in and sign stating you Falls approved(stamped) plans. * Maximum Occupancy signs posted where required. know what those issue are,that you will have them completed by the specified time,and will call for inspection as those items are *Special Inspection reports and balance reports need to be received by our office. completed. It is up to each department to determine if you meet their qualification for temporary occupancy. Storm Water Facility Inspections:(33 phases) * Inspection of excavation, including dimensions and geotextile fabric.All adjoining trenches leading to storm water facilities PLANNING&ZONING NOTE: If a building was originally done as a shell,the shell building permit is required to be finaled prior the tenant improvement also need to be excavated and inspected. permits can be finaled. In addition, if Temporary Occupancy is needed there will be$1,000 refundable deposit for each permit. * Inspection of storm drain pipes(per plans)need to be in place(not covered)for visual inspection.The drain rock must meet Landscaping ISPWC section 801 Drain Rock requirements.All pipe connections to storm water facilities must be completed. *City code allows us to issue a TCO with landscaping incomplete. However,we cannot extend * Inspection of completed storm water facilities with the above referenced drain rock and geotextile fabric showing proper the on a definTCOitive beyond the current planting season.This means that we will work with the applicant date of their choosing, but not typically beyond 2 3 months. cover and overlap. Trash Enclosures: Site Inspections: Please have the Address posted on site for all inspections. *Trash enclosures should be finished before a final inspection is requested, including the front *Verify that the parking lot layout(design)and striping matches the plans. gate on the enclosure. *Verify that the parking lot surface is an approved"hard"surface. Please have a printed COLOR copy of City Approved Plans on site for all inspections. *Verify that there is ADA compliant access from the Right-of-Way(ROW)to the building envelope. We cannot issue a TCO if this item is not completed. Right-Of-Way Inspections. *Verify driveway approach widths and locations according to plans. *Verify ADA compliance of Curb/Gutter,Sidewalks,and Sidewalk/Driveway combinations. *Verify ROW connections to other Agencies/Entities meet's ADA tolerances. 2018 IBC Section 105.4 Validity of Permit: Flood Plain Inspections: *Verify flood plain location and compare plans to the site. 2018 IBC Section 105.4 Validity of Permit: The issuance or granting of a permit shall not be a permit for, or approval of, any violation of any of the provisions of this code or of any other *Verify the commercial buildings are one foot above base flood elevation. ordinances of the jurisdiction. Permits presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the building official from requiring the correction of errors in the construction documents and other data. The When ready for inspection please call the Engineering inspection line at 208.735.3446. For same day inspections,call before building official is authorized to prevent occupancy or use of a structure where in violation of this code or of any other ordinance of this jurisdiction. 7:30 am. Having these inspections approved when the work has been completed will ensure the Certificate of Occupancy is issued in a timely manner. Additional general comments specific to this permit Reviewer comments and markups included in final approved plan set. CITY APPROVED PLANS Reviewed for Code Compliance PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Page 1 of 3 32" CLEAR MIN. Pocket Door. � 5 2858 Exhaust fan 12'- " V! C N 3 0 N 5'-0 11 5-0° _I a 0 a ----------- 0 33"-36" 8"-4 3 " New. 2'-91I2 0 33"-3 .. Our carpenter shop. -----—- �74 -Grab bar height 3"-36" ADA sink Grab Bars Metal studs to be provided. Non-combustible construction. EXHAUST FAN TO BE INTERCONNECTED WITH LIGHTS OR TIED INTO MAIN BUILDING EXHAUST CITY APPROVED PLANS SYSTEMReviewed for Code Compliance PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS IA- 1 Page 2 of Mirror Height(§603.3) measured to the bottom of Ai; the reflecting surface Faucets(§606.0) comply as operable parts E ' FIG.609.3 SPACING OF GRAB BARS Lavatory Height(§606.3)measured to the rim or counter,whichever Exposetl Plumbing(§606. 54" Min. u higher E protected against c x Clear Floor Space(§606.3) 3911-4111 fora forward approach 18" oft 0o. 8" l MIN z 7-MIN MAX KNEE 00 CLEARANCE e z TOE z "' CLEARANCE 21 Toilet Paper Dispenser 6" 11" MAX MIN CITY APPROVED PLANS Reviewed for Code Compliance PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS A-2 Page 3 of 3