HomeMy WebLinkAbout17-1630 801 Pole Line Rd W Remodel 4th Floor Plans - - - - - - - - - - - - - - - - - - - - ARCHITECT HUMMEL ARCHITECTS PLLC 2785 N BOGUS BASIN ROAD BOISFAX: ID 83702 08.34 PHONE:208.343.7523 CONTACT: MANDY BOAM co NEW HOSPITALIST OFFICE MAFAX: 208.343.0940 EMAIL: mboam@hummelarch.com co co GIC MECHANICAL ENGINEER a ENGINEERING INCORPORATED 2222 BROADWAY AVENUE VALLEY MEDICAL CENTER ol BOISE,ID 83702 PHONE:208.343.3663 CONTACT: MICHAEL GREFENSON 0� FAX: 208.343.9625 EMAIL: michaelg@engineeringinc.00m OQ � J ELECTRICAL ENGINEER 801 POLELINE ROAD, TWIN FALLS, ID LU CH2M HILL StLu 9 o 322 E.FRONT STREET d BOISE,ID 83702 CONTACT:JOHN HATTEN PHONE:208.345.5310 EMAIL: John.Hatten@ch2m.com C=) co GENERAL NOTES MATERIAL & SYMBOLS PROJECT LOCATION & FIRE/SMOKE PLAN 1. DO NOT SCALE DRAWINGS. W 2. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO WORK. O REFERENCE TAG 3. SCREENED LINES REPRESENT EXISTING WALLS,DOORS,WINDOWS,ETC. RATING LEGEND: z 4. WHERE NEW CONSTRUCTION ABUTS EXISTING,NEW WALL SHALL MEET AND MATCH EXISTING FINISH "' °°"Wa"'� r ACCESSORY TAG W AND PLANE SO THERE IS NO NOTICEABLE SEAMS OR BREAKS IN THE FINISH PLANE.5. PROTECT IN PLACE EXISTING CONSTRUCTING NOT NOTED FOR DEMOLITION.ANY DAMAGE TO W U�E �w EXISTING CONSTRUCTION SHALL BE REPAIRED TO ORIGNINAL STATE. GRI-EVEL HEAD ....... `° 6. WHERE EXISTING WALLS ARE REMOVED,PATCH THE FLOOR AREA WITH PATCHING COMPOUND AS RECOMMENDED BY FLOORING MANUFACTURER. Pµw LL U 7. SALVAGE ITEMS AS NOTED ARE TO BE STOCKPILED IN COMMON LOCATION AS DIRECTED BY THE - °`a`'a 9 WALLTYPETAG O 8. WHERE EXISTING CONSTRUCTION TO REMAIN ADJOINS DEMOLISHED ITEMS AND WALLS,PATCH AND REPAIR THE EXISTING CONSTRUCTION SO THERE IS NO NOTICEABLE SEAMS OR BREAKS IN THE FINISH ROOM NAME ` II-- W PLANE. ® ROOM TAG a 150 SF ` zanw rxn J MST/ 1-2 SMOEZINE ® J >— LL,m CASEWORK TAG ,11Tr '.•` ' v, MEuu"as o J m'c zn dz PROJECT DESCRIPTION 36' 16" DIAGNOSTIC TREATMENT VJJ J 5 t u� FL L m r o 36" �/� Extra Shen _ - VJ �oP mai ��••• � ..1...N m N N SL PROJECT#: 17 531 VIEW#ORLETTER— , SIM DETAIL OR ENLARGED V � X. O SHEET# P#k# PLAN CALLOUT •�•' r� � /UI� L! ' •- INPATIENTTOWER - - la •.. \ � V PROJECT TENANT: VIEW#QRLETTER , � ST.LUKE'S MAGIC VALLEY-HOSPITALISTS ® W Q 851 POLELINE ROAD WEST SHEET# p#,## INTERIOR ELEVATION O • C TWIN FALLS,ID 83301 z c � 1 B.O.DECKS LEVEL NAME ELEVATION MARKER MOBi XXVPROJECT OWNER/CONSTRUCTION MANAGER: rSt L.�3 PROJECT LOCATION PROJECT LOCATION ST.LUKE'S HEALTH SYSTEM 851 POLELINE ROAD WEST NORTH ARROW #17 531 i TWIN FALLS,ID 83301 AMOS KINGTON FZ 51101�ZOtE PROJECT DATE 17 PHONE:208.814.1705 — D CHECKED ED DRAWN CHECKED PROJECT: a AF APPROXIMATELY 419 SF REMODEL TO AN EXISTING LOBBY ON THE 4TH FLOOR OF THE ST.LUKE'S NEW SMOKE PARTITION(IN RED)TO MAGIC VALLEY REGIONAL MEDICAL CENTER.SCOPE OF WORK TO INCLUDE(1)OFFICE SPACE. SEPARATE NEW OFFICE FROM LOBBY PER VIEW# 1 law Name VIEW TITLE SEPARATE OFF/ REVISED A- SCOPE ELECTOFWOROLITIONTOINTERIORSPACETOOCCURTOACCOMMODATENEWCONSTRUCTION SHEET# A101 1/8"=T-0" MAGIC VALLEY MEDICAL CENTER FIRE/SMOKE PLAN - MODIFIED # Description Date LEVEL FOUR LEVEL FOUR ABBREVIATIONS DRAWING INDEX # NUMBER OR POUND CAB CABINET ELEV ELEVATION GA GAUGE MFR MANUFACTURER PC PAINT COLOR BHT SHEET GENERAL MECHANICAL e DIAMETER CPT CARPET EP EPDXY PAINT GALV GALVANIZED MIN MINIMUM P.I.V. POST INDICATOR VALVE SHTG SHEATHING Wl WITH GO.0 COVER SHEET M1.0 MECHANICAL COVER SHEET ti ANGLE C.I.P. CAST-IN-PLACE EQ EQUAL GB GYPSUM BOARD MISC MISCELLANEOUS PLAST PLASTIC SIM SIMILAR WC WATER CLOSET _ AT CJ CONTROLJOINT EQUIP EQUIPMENT GYP.BD. GYPSUM BOARD ML MEASURING LINE PLYWD PLYWOOD SPECS SPECIFICATIONS WD WOOD r ARCHITECTURAL N � &� AND CL CENTERLINE ESTR EXPOSED STRUCTURE MO MASONRY OPENING PR PAIR SO SQUARE WE WALL FABRIC M4.0 HVAC FOURTH FLOOR PLANS CL CENTERLINE CLG CEILING (NEW OR EXISTING) HAS HEADANCHORSTUD MTD MOUNTED SS STAINLESS STEEL WH WATER HEATER A1.0 DEMO PLAN,REMODEL PLAN _ SHEET TITLE CMU CONCRETE MASONRY UNITS EIFS EXTERIOR INSULATION HCW HOLLOW CORE WOOD MTG MOUNTING R THERMAL RESISTANCE STD STANDARD WM WALK-OFF MAT COVER `o AB ANCHOR BOLT GO CLEAN OUT &FINISH SYSTEM HM HOLLOW METAL RCP REFLECTED CEILING PLAN STL STEEL W10 WITH OUT A6.0 FINISH PLAN,INTERIOR ELEVATIONS& ELECTRICAL ACP ACOUSTICAL CEILING PANEL COL COLUMN EXIST EXISTING HORIZ HORIZONTAL NA NOTAPPLICABLE RO ROOF DRAIN STOR STORAGE WP WATERPROOF DETAILS E1.0 ELECTRICAL COVER SHEET ACT ACOUSTICAL CEILING TILE CONC CONCRETE EXP EXPANSION HT HEIGHT NB NO BASE(EXPOSED RDL RAIN DRAIN LEADER STRUCT STRUCTURAL WRGB WATER RESISTANT LV SHEET ADJ ADJUSTABLE CONST CONSTRUCT EXT EXTERIOR HW HARDWOOD WALL OR FOUNDATION) RE: REFERENCE SUSP SUSPENDED GYPSUM BOARD Ag.O RCP DEMO&REMODEL PLAN ES FIRE ALARM PLAN Z °- AFF ABOVE FINISH FLOOR CONT CONTINUOUS NC NEW CONCRETE REFRIG REFRIGERATOR SV SHEETVINYL Wr WEIGHT E.0 LIGHTING PLAN s ALUM ALUMINUM CSK COUNTERSINK FD FLOOR DRAIN ICMU INTEGRAL COLORED NIC NOT IN CONTRACT REINF REINFORCING WWF WELDED WIRE FABRIC ANOD ANODIZED CMT CERAMIC MOSAIC TILE F.D.C. FIRE DEPARTMENT CONNECTION CONCRETE MASONRY UNITS NM NEW MASONRY RED REQUIRED T&G TONGUE AND GROOVE Al1.0 EQUIPMENT PLANS E0.0 POWER PLAN APPROX APPROXIMATE COT CERAMIC QUARRY TILE FB FIRE BLANKET ID INSIDE DIAMETER NO NUMBER RE EPDXY FLOOR SYSTEM TEMP TEMPORARY ESO POWER PLAN ASSOC ASSOCIATED CWB CERAMIC WALL BASE FE FIRE EXTINGUISHER INSUL INSULATION NOM NOMINAL RM ROOM TO TOP OF AWP ACOUSTICAL WALL PANEL FF FACTORY FINISH INT INTERIOR NTS NOT TO SCALE RO ROUGH OPENING TOM TOP OF MASONRY AWS ACOUSTICAL WALL SYSTEM DEL DOUBLE F.H. FIRE HYDRANT INV INVERT RST RUBBER STAIR TREADS TS TUBE STEEL W j DEPT DEPARTMENT FIN FINISH OC ON CENTER RW REDWOOD TYP TYPICAL SHEET BD BOARD DT DETAIL FL FLOOR LINE JAN JANITOR OD OUTSIDE DIAMETER RWB RUBBER WALL BASE 1-2 OCCUPANCY BFC BROOM FINISH CONCRETE DF DRINKING FOUNTAIN FLR FLOOR JST JOIST OFF OFFICE RWC RAIN WATER CONDUCTOR LON UNLESS OTHERWISE NOTED II-B CONSTRUCTION E BLDG BUILDING DIA DIAMETER END FOUNDATION JT JOINT OFCI OWNER FURNISHED/ W a BLKG BLOCKING DIM DIMENSION FOC FACE OF CHANNEL CONTRACTOR INSTALLED Sc SEALED CONCRETE VAR VARIES 8 OCCUPANT LOAD BM BEAM DN DOWN FOE FACE OF FINISH LAB LABORATORY OFOI OWNER FURNISHED/ SCHED SCHEDULE VCT VINYL COMPOSITION TILE BO BOTTOM OF DS DOWNSPOUT FOS FACE OF STUDS LAM LAMINATE OWNER INSTALLED SCW SOLID CORE WOOD VERT VERTICAL BOT BOTTOM FT FEET LAV LAVATORY OPNG OPENING SGWB SUSPENDED GYPSUM VEST VESTIBULE U BRG BEARING EA EACH FTG FOOTING OTA OPEN TO ABOVE WALLBOARD ttl-t " BSMT BASEMENT EBT EXPANSION BASE TRIM FV FIELD VERIFY MAT METERIAL OTS OPEN TO STRUCTURE 1of12 BTWN BETWEEN EJ EXPANSION JOINT MAX MAXIMUM OVF OVERFLOW W _ ELEC ELECTRICAL MECH MECHANICAL MET METAL 7/10/17 c� � REFERENCE NOTES 0 1.01 3-5/8'STEEL STUD WITH GYPSUM BOTH SIDES.PROVIDE SOUND ATTENUATION INSULATION IN STUD CAVITY.RE:GENERAL NOTE#11. 2.07 REMOVE AND RELOCATE EXISTING FIRE EXTINGUISHER. COORDINATE NEW LOCATION WITH REMODEL FLOOR PLAN 31A1.0. lul lul 2.10 EXISTINGFLOOR FINISH.REMOVE AS NEED FOR NEW WALL CONSTRUCTION.PRESERVE AND PROTECT.REPAIR DAMAGED AREAS TooLo STATE. 6.40 COAT HOOKS MOUNTAT4'-0"AF.F.MAX.SEE DETAIL 7/A6.0. 8.04 NEW 36"WIDE X V-10'HIGH NONRATED WOOD DOOR IN A PAINTED o (P-21 HOLLOW METAL FRAME.DOOR TO HAVE 1-1/2 PAIR HINGES,WALL 2.07 BUMPER SMOKE SEAL,DOOR SWEEP,OFFICE T. Q 21.01 RELOCATED,EXISTING FIRE EXTINGUISHER.RE::DETAIL Ou � J LL Lai Z J Z W O d LOBBY 2.1D 0 N4010 CO GENERAL NOTES 1. UNLESS NOTED OTHERWISE,ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR GWB WALLS/PARTF IONS. 2. SCREENED LINES REPRESENT EXISTING WALLS,DOORS,WINDOWS,ETC TO REMAIN.PROTECT FROM DAMAGE DURING CONSTRUCTION ACTIVITIES. 3. FOR DIMENSIONAL EXTENTS OF EXISTING WALL DEMOLITION,CUTTING AND PATCHING,SEE NEW FLOOR PLANS. 4, PROTECT FROM DAMAGE ALL EXISTING TO REMAIN CASEWORK, EQUIPMENT,FLOOR FINISHES AND CEILING FINISHES DURING W CONSTRUCTION. ui 5. PROTECTFROM DAMAGE DURING DEMOLITION,MOVING AND CONSTRUCTION ALL EXISTING CASEWORK,EQUIPMENT,FURNITUREAND ARORK THAT IS TO BE z 6. SEE MECHANICAL AND ELECTRICALS DRAWINGS FOR ADDITIONAL t W DEMOLITION WORK. ui 7. COORDINATE THE DEMOLITION OF EXISTING CEILING WITH NEW PLANS, REFLECTED CEILING PLANS AND ROOF FINISH SCHEDULE. v J 8. WHERE EXISTING CARPET/CARPET TILE ARE TO REMAIN,CUT AND PATCH CARPET AS REQUIRED TO FACILITATE NEW CONSTRUCTION. 9. FOR FLOOR FINISHES RE:ROOM FINISH SCHEDULE AND FINISH PLAN ON U— ! , SHEET ORGAZIN O C:, 10. FOR GLAZING N SECTION WINDOW TREATMENTS,HORIZONTAL Q SPECIFICATION SECTION DIVISION 12-HORIZONTAL LOUVER BLINDS. 11. AT NEW CONSTRUCTION,PROVIDE CONTINUITY OF SMOKE PARTITION PER NFPA SECTIONS 8.4 AND 19.3.6.2. ui G I 12. RE:SHEETS G1.0 FOR LEVEL 04 FIREISMOKE PLANS. V) J � W LEVEL FOUR- DEMO FLOOR PLAN Q w o A1.0 1/4"=V-0" m O ^ J -2 L _ J t m r o LEGEND U) Q z y O "soo 2 NIL NN �® WALL TYPE,RE:A1.0 ` , w FIRE EXTINGUISHER CABINET.RE:DIVISION 10- SPECIALTIES10 AND SHEET I/A1.0. W Q o STEEL STUD WALL AND GYPSUM BOARD WALL.RE:WALL z TYPES. DURINGEXIST�NGWAULSYSTEMTOREMAIN.PROTECT FROM DAMAGE J L u u DURING ALL SYSTEM ���St W EXISTING WALL SYSTEM TO BE REMOVED. EXISTING DOOR SYSTEM TO REMAIN.PROTECT FROM DAMAGE DURING CONSTRUCTION. ®0 PROJECT DATE EXISTING DOOR SYSTEM TO REMOVED. 17013 06/142017 \6 DRAWN CHECKED r — AF J01 REVISED: # # Deecnption Date BLOCKING EACH SIDE OF L LINE RECESS TO CABINET ATTACHED TO 3 (y RECEIVE CABINET WITH STUDS.ALSO USE METAL 518"GYPSUM BOARD STUD HEADER ANDA6.0 4 ALLAROUND-TOPAND BLOCKING ABOVE AND LOBBY HOSPITALIST BOTTOM,BOTH SIDES BELOW CABINET. OFFICE AND BACK. N4010 p 419 SF 1.01 0 6.40 o r_ FIRE EXTINGUISHER CABINET SECTION ^ INTERIOR PARTITION- � SEE WALL TYPES N SHEETTITLE DEMO PLAN, W REMODEL Fl 1 8 PLAN ELEVATION W jSHEET W U A1 .0 �2 FIRE EXTINGUISHER CABINET DETAIL s LEVEL FOUR-COMPOSITE FLOOR PLAN w A1.0 3"=V-01' A1.0 1/4"=1'-0" 0 Q - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - REFERENCE NOTES 0 ROOM FINISH AND CASEWORK SPECIFICATION INFORMATION: 5.03 3.5/8'METALSTU0. y 6.01 2X WOOD FRAMING AND BLOCKING lul 6.08 OPEN KNEE SPACE 6.20 UNDER COUNTER SUPPORT,EQUALLY SPACED AT S-0"O.C.,MAX., U.N.O.,WHERE OCCURS,RECESS 1'FROM END OF COUNTERTOP. WALL FINISHES: CASEWORK FINISHES: WINDOW COVERINGS 6.27 1-1/4'PLASTIC LAMINATE WRAPPED PANEL CORE COUNTERTOP.SEE Lo FINISH DRAWINGS FOR FINISH MATERIAL. M^ P-1 VERTICAL SURFACES: WC-1: 6�_ �yl 6.38 PLASTIC LAMINATE FILLER PANEL,BEYOND.NO TOE KICK.ALIGN WITH GENERAL PAINT MANUFACTURER:WILSONART MANUFACTURER:HUNTER DOUGLAS CONTRACT U FACE OF WALL FINISH.COORDINATE WITH FLOOR PLAN AND FINISH �o MANUFACTURER:BENJAMIN MOORE STYLE:SHAKER CHERRY 7935-07. STYLE:MANUAL ROLLER SHADE SCHEDULE. COLOR:IVY LEAGUE-516,SUPER SPEC HARDWARE PULL:4"SATIN NICKEL WIRE PULL SHADE CLOTHE:GLACIERSCREEN HD 2001 Q FINISH:PEARL COLOR:WHITE SAND 6.39 BASE CABINET.COORDINATE NTH INTERIOR ELEVATIONS. _ TRANSPARENCY:1% 6.41 3/4"PLASTIC-LAMINATE-FACED PANEL CORE. P-2 HORIZONTAL SURFACES: FASCIA:TO MATCH WINDOW FRAME END CAPS. 104 INTERIOR TYPE W'GYPSUM WALL BOARD HOLLOWMETAL DOOS AND FRAME PAINT MANUFACTURER:WILSONART �� 9.08 WALL BASE.MATCH EXISTING. MANUFACTURER:BENJAMIN MOORE STYLE:WESTERN SUEDE,4871-60 �1' 9.19 PAINT BOTH SIDES OF NEW WALL P-1.PAINT ENOUGH OF EXISTING COLOR:HG80BLEEKERBEIGE �1, Q �S COLUMN TO ENSURE NO VISUAL DIFFERENCE. Q _ FINISH:SEMI-GLOSS 9.20 PLACE WF-13M FILM ON GLAZING SURFACE. Q WINDOW FILM: uj GYPSUM BOARD CEILING PAINT 10.32 COAT HOOK. � J -1' L 12.01 WC-1 MANUAL ROLLER WINDOW SHADES. J MANUFACTURER:3M FASARA GLASS FILM MANUFACTURER:BENJAMIN MOORE 3 LL Q STYLE:SH2 MAOW COLOR:SUPER WHITE Z COLOR:OPAQUE WHITE - ' FINISH:FLAT I 4 I J Z_ ' HO A6.0SPITALIST z.o1 W LOBBY OFFICE 2 �� O N4010 419SF �? O 9.19 i 00 GENERAL NOTES 1. RE:ROOM FINISH SCHEDULE SHEET FOR ADDITIONAL INFORMATION ON FLOOR FINISHES. �1201 2. ALLVCTPATTERNS ARE TO BE FULL TILES EXCEPT WHERE PATTERN IS INTERRUPTED BY PORTIONS OF BUILDING. 3. RE:ROOM FINISH SCHEDULE AND FNISH FLOOR PLANS FOR MATERIAL AND 0 0 FINISH INFORMATION. -- 4. FOR CODE AND FIRE INFORMATION,RE:GI.0 AND AI.0. 5. PROVIDE RWB AT ALL TOE SPACE OF ALL CABINETS,SIDES OF CABINETS AND ALL KNEE SPACES BELOW CABINETS. 6. RE:FLOOR PLAN FOR DOOR AND FRAME TYPES. _____________ ____ _____ ___________ _____ Lu 7� Z 1 w LEI 0 LEGEND c) j 3M FILM LL_ U �0 Q VJ Lu o ABREVIATIONS J LEVEL FOUR- FINISH FLOOR PLAN Q >_ Lu o 1 A6.0 114"=11-01. CEILING FINISHES WINDOW COVERINGS < U J o m ACP ACOUSTICAL CEILING PANEL WC WINDOW COVERING -1CC m c a- J Ltm f^ o�vi ai WALL FINISHES WINDOW FILM I J uZi y ro.0 P PAINTCOLOR WF WINDOW FILM O /> =N A2 N N CASEWORK U PL PLASTIC LAMINATE ui Q CASEWORK TAG LEGEND Z 2i fi.27 MODIFICATION t_TIII,C___T MODEL #. 1�LSt S fi.38 MODIFIED IT_ �IILl -Ju`_ NUMBER MODIFIED CABINET '--- a Ta�J a T '9� F '6� dF '6�J M - - WIDTH+36" 16'-DEPTH - - - _ 6.08 - _ 6.08 36"-HEIGHT 6 Extra SheK PROJECT DATE �211424' a ., MODIFICATION 17013 -14/20179112"J 3'-31I2" 3'-10". . 2532232' MODEL INDICATES MODEL NUMBER OF AWS DRAWN CHECKED 223 18' 24'18" 24" 223 223 253NUMBER CABINET AF ,7" 24" 30" 30' 18' 24' 18" 24" 18' 24' INDICATES A MODIFIED VERSION OF THE 30" 30" 17„253 24. 30' 17. 253 24. 30" 253 30" 30" M AWS CABINET MODEL REPRESENTED BY REVISED: 18" 24" THE PRECEDING NUMBER. # 30' 30" 30„ AADE INDICATEDPTION BY HE THE MODIFICATION # Description Date MODIFICATION MADE INDICATED BY THE IM)FOLLOWING 2 HOSPITALIST OFFICE-SOUTH 3 HOSPITALIST OFFICE- NORTH �a HOSPITALIST OFFICE- EAST THE MODEL NUMBER A6.0 14,=1 01, A6.0 1/4"=1'0" WIDTH INDICATES WIDTH OF CABINET, A6.0 1/4"=1'-0" DIMENSIONED FROM OUTSIDE FACE TO OUTSIDE FACE. 3l4' INDICATES DEPTH OF CABINET, DEPTH DIMENSIONED FROM FACE OF WALL TO FACE OF CABINET EXCLUDING CABINET DOOR WHEN DOOR APPLIES 8.41 DIMENSIONED HEIGHTDICATE CABINET,FROM FACE OF FINISHED HEIGHT FLGOR TO TOP OF COUNTERTOP FOR BASE CABINETS AND FROM BOTTOM OF 627 10.32 CABINET TO TOP OF CABINET FOR UPPER CABINETS. 6.27 6'39 6.01 FACE OF WALL N 6.01 2318" SHEETTITLE 904 FINISH PLAN, 9.04 SECTION Lu Z INTERIOR 5.03 4' 4" 6.41 ELEVATIONS TYP TYP I I I , 5.03 10.32 & DETAILS Lu I 9.08 I I w SHEET W I I I I I I ELEVATION V A6.0 Z 5 COUNTER DETAIL �s COUNTER DETAIL AT WINDOW SILL K-i�COAT HOOK BASE DETAIL 0 c� A6.0 1"=11-0" A6.0 1°=1'-0.1 A6.0 3.=1'_0° - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - REFERENCE NOTES O 2.08 REMOVE EXISTING CEILING TILE.COORDINATE REMOVAL WITH REMODEL FLOOR PLAN(A1.0),LIGHTING PLAN(E7.0),AND HVAC FLOOR PLAN(M4.0). L M �o GENERALNOTES -' 1. UNLESS NOTED OTHERWISE,ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR GWB WALLS/PARTITIONS. Q 2 2. SCREENED LINES REPRESENT EXISTING WALLS,DOORS,WINDOWS, — ETCTOREMAIN.PROTECT FROM DAMAGE DURING CONSTRUCTION Q ACTIVITIES. co 3. FOR DIMENSIONAL EXTENTS OF EXISTING WALL DEMOLITION,CUTTING J AND PATCHING,SEE NEW FLOOR PLANS. LL( Q 4. PROTECT FROM DAMAGE ALL EXISTING TO REMAIN CASEWORK Z LL_ EQUIPMENT,FLOOR FINISHES AND CEILING FINISHES DURING J Z CONSTRUCTION. W LOBBY5. PROTECT FROM DAMAGE DURING DEMOLITION,MOVING AND N4010 CONSTRUCTION ALL EXISTING CASEWORK,EQUIPMENT,FURNITURE Q AND ARTWORK THAT IS TO BE RE-USED. d 208 6. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION WORK. p 7. COORDINATE THE DEMOLITION OF EXISTING CEILING WITH NEW PLANS, 00 - REFLECTED CEILING PLANS AND ROOM FINISH SPECIFICATIONS. 8. PATCH WHERE EXISTINGAS REQUIRED OF FACILIILE TATE NRE CONSTRUCTION. ■ COORDINATE ETAS REQUIRED AL FACILITATE NEW CONSTRUCTION. 9. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL ITEMS TO BE PROVIDED AT THE CEILING PLANE AND IN THE WORK. 10. CENTER ALL LIGHT FIXTURES AND SPRINKLER HEADS IN THEIR RESPECTIVE CEILING PANEL. - ® 11. CO ORDINATE WITH MECHANICAL&ELECTRICAL DRAWINGS AND C SPECIFICATIONS FOR PHYSICAL SIZES OF ALL CEILING GRILLES, DIFFUSERS,FIXTURES,CANS,AND ALL RELATED ITEMS. 12. AT NEW CONSTRUCTION,PROVIDE CONTINUITY OF SMOKE PARTITION PER NFPA SECTIONS 8.4 AND 19.3.6.2. n/ 13. RE:SHEETS G1.0 FOR LEVEL 04 FIRE/SMOKE PLANS. LJ_ w 7� Z LEGEND w w U SYSTEM WITH CAL ACOUSTLINGICAL METAL SUSPENSION SYSTEM WITH ACOUSTICAL PANEL CEILING J UNITS,APC-1,U.O.N.RE:DIVISION 09-FINISHES Ts IN THE SPECIFICATIONS I LL V RCP DEMO SUPSUMPORT OARD SYSTEM. PING ON STEEL.N.FRAMING AND O Q SUPPORT SYSTEM.PAINT-P-3,U.O.N.RE: DIVISION 09-FINISHES IN THE SPECIFICATION, w m A9.0 1/4"=1'0" C 0 G c VERTICAL SERVICE DROP/CHASE.COORDINATE J m WITH MECHANICAL DRAWINGS. L Cu m o w < om ❑0 LIGHTING FIXTURES,COORDINATE WITH J m o ELECTRICAL DRAWINGS. © 0 v a y MECHANICAL FIXTURES,COORDINATE WITH v J > 'o 0 0 MECHANICAL DRAWINGS. O 2 N m N N 2 0 �X-X" CEILING HEIGHT ABOVE FINISH FLOOR '^ w C< —_ EXISTING CEILING SYSTEM TO REMAIN.PROTECT Z G FROM DAMAGE DURING CONSTRUCTION. LL EXISTING GYPSUM BOARD CEILING TO REMAIN. J1r St 4." PROTECT FROM DAMAGE DURING CONSTRUCTION. 1 r#17-531 PROJECT DATE L—J L—J 17013 06/14/2017 L-J--i--L-i EXISTING CEILING SYSTEM TO BE REMOVED. HOSPITALIST DRAWN CHECKED �- --OFFICE REMOVED. AF LOBBY -' EXISTING GYPSUM BOARD CEILING TO BE N4010 41 SF t' :9 REMOVED. REVISED: r—, r—, # Deecnption Date L J L_J � EXISTING LIGHTING FIXTURES TO REMAIN, COORDINATE WITH ELECTRICAL DRAWINGS. 0 COISTING ORDINATE WITH MECFHAN CAL DRAWI TO NGS. CEXISTING LIGHTING FIXTURES TO BE REMOVED, EA0`-� COORDINATE WITH ELECTRICAL DRAWINGS. r a r a EXISTING MECHANICAL FIXTURES TO REMOVED,COORDINATE WITH MECHANICAL r 0 DRAWINGS. � N SHEETTITLE w RCP DEMO & REMODEL JOIN PLAN 2 RCP REMODEL w A9.0 1/4"=1'-0" j SHEET W z Z A9.0 U W 0 Q - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - REFERENCE NOTES 0 10.25 METAL LOCKER.IT WIDE,(2)OPENINGS.(GRAINGER BLACK TIE LOCKER OR APPROVED EQUAL). 10.26 NEW DUAL MONITOR COMPUTER SYSTEM.I.H.T.TO SUPPLY AND INSTALL. 10.28 NEW TASK CHAIR.SUPPLY CHAIN TO SUPPLY AND INSTALL. 10.29 NEW COUCH.SUPPLY CHAIN TO SUPPLY AND INSTALL. 10.30 NEW CONFERENCE TABLE.SUPPLY CHAIN TO SUPPLY AND INSTALL. �t 10.31 NEW DESKTOP TELEPHONE.I.H.T.TO SUPPLY AND INSTALL �o Q 0 0 C 10.26 10.31 Q 0 F � J 0.31 Z u- z GENERAL NOTESLU L o.zs o O LLLI 1. EQUIPMENT LOCATIONS ARE TO BE VERIFIED WITH OWNER PRIOR d TO INSTALLATION. HOSPITALIST 2. ALL QUESTIONS OR INCONSISTENCIES REGARDING EQUIPMENT CD W SHOULD BE DIRECTED TO OWNER. LOBBY OFFICE 3. RE:ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS. N4010 419 SF ;4-, TYP(3) 10331 TYR(3) 10.26rl n/ 0 0® 0 Lu LLI (> LL Q LL U 00 H LL] LLI o J LEVEL FOUR- IT EQUIP PLAN Q w Co� g 'I..L J L r mro V) �-y O > °ro 2 '000 NmNN 2 U W Q �� ---------------- P. �r$t Ll"S I � o 1 r#17-531 1029 PROJECTPF EDATE 10 28 i� 17013 TYR(8 10.28 DRAWN AF 10.30 IL _ 10.28 /I REVISED: "' o 10.25 ,�____�_�____� # Description Date 11 HOSPITALIST LOBBY -, OFFICE N4010 '�"'i 419SF 0.28 0 /-Typ(3) 10.28 0® o® 0® O - - Lb N �� SHEETTITLE w EQUIPMENT PLANS > SHEET 2 LEVEL FOUR- EQUIP PLANLu A11.0 „4. Z Al 1 .0 W C7 Q - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - GENE•DAS,C,1E(HANICAI.REQDIBDMENTS MECHANICAL LEGEND 15010 All work,hdl wnfoxm to latest adopted v,teim.,f)FC,SMACNA,UPC,IMC,NFPA,IFC,1FGC and all other applicable codes cnf W by 1 In I �ha'g j -d-T 'I,scoRALpe of the work 1 d d d lhrs Di mien of the Speeif—iCn shall inclose meCho.wel sy—as sh the pl '1'h 1, h I hell p -a all p I bo, SYMBOL DESCRIPTION NQ r I q'p h Y PI t d any and all other items of,tipmmt as indicated on lh drawing d r,'rod f I I W d p t al y'I C. Irac h II 8 Il ry brain aml pay 1 all pamr(s;paY nil governmcnl salt I f d ih 1 I k fl all necessary plans, •�rye,�y p Pat lid d b 11 y'W T f'nspechiox for his work and dcliva set >h U gi M1! req p df Ip y P he work, NrIU TO EXISTING CONNECTION q" O All me I.' Ildhall b. h I1L161 i W11M1 fll gM1S dofhestqualny w,thh br d 1 t edf h 1 solm rr al or equipment ILe C I I M1 f[Ilow I aw nga n lay,g o,t work,check d gs f ner lade.aW v ify arW uondtLLons iv wl ich work will be Installed I C7 Thee ea W shNlp test all work,maWnal ana,xtshng lu n g It—damage by ht.work or wo k ee and shall be lable for an damage tons canned. ---------------- TYPICAL DEMOLITION ITEMS 05 ~�� All equipment,units,sb—othor i.e,shall be securely elIwIWWWe budding shictm'e In an approved manna T rwo c,mplcw s,UIf bh,clineal-huinmxhmi,al drawings will be provided for the builmng swan,i,m Tproved marlmT. TYPICAL EXISTING ITEMS P,,vid-dig' 1 tof ML(_HANICALSUBMI'f1AL3f the ArvhiWut anJ Eiighie,'a review,Idedifyu,ffiefollowing. 1.Sappli ae t pm Y andaB Wntaetnrminmi,n � SPIN-IN FITTING WITH HAND DAMPER 2.schedulC o-I'st of all`q'p ncin,inclumrig tnako,type,mamifaehmer's name,and lade drsignanon of all materials and cqu,pmcnt to be used and f—khed. 3.Include,„nplete list,fail acrossoaos and options provided. d.Equipman per, adng,and,,,Cates-mime,f C. , blown ohane,—fie nmrpant,nta,avandvest,pressure drops,RPM Valois, ,map,, rain,,ognipmem ® � SUPPLY DUCT(UP OR DOWN) n,fni.n xaaranac,and color e xdwgion S.Lisls111 d—lions If a equipment, are necessary to check space requ¢etnrntc 0 s RETURN DUCT(UP OR DOWN) All work under this section shall be guamm„d in writing to be free of d I-we work,motorist,m pars£,,ap'aiod of one year after accgd—of the contraca. y SLL x riC DEMOLITION ® 11 EXHAUST DUCT(UP OR DOWN) �QTIS (p Disco neat,demolish and remove mechanical ey—,equipment and wmpeeenta i diCeted W be removed.1f pipe,insulation or equipment to ruses.is damaged in appearance or is . n-eeanle,r„n,..damagcaor unaaviceable portion,and raptaeewith new pmdeea,rCold CV,,dy awl quahty- 'm/1'WN1 FLEXIBLE DUCT LLl < LPipingorducttoberes,ovul�ILem,vo portion oipiping or duct xyslanindicated on Drawings and cap nrplug remaining piping,,duct with same or wmpatlble mnmrlal. Z 2.Pip g d b b d d'pl—D—C PpI, d PPP g 1,d withsamenr emmpdi hle mafaial _ 3.Eyi p ..t b d Cq p t. ®� CEILING SUPPLY DIFFUSER J Z a.Fqr p Ito he rem,ue,l and reinstalled.Disconnect a,e rip crvicea,remove,clean and,Wre equipment;roinatall,reconnect end make equipment opemimnal. L S.E,pdpincnt to be re moved and salvaged:Dine—end cap xivims;remove egmpmcnt and deliver to Owner CEILING RETURN GRILLE 0 F— 15060-HANGERS AND SUPPORTS CL GENERAL ®--r CEILING EXHAUST GRILLE Ha ngers nd suppm Cu O 6>5 'M�' �asidwfWby wnnt lm 00 N PRODUCTS SIDE WALL GRILLE OR LOUVER 3 0°+°1• r M M— $P v auafaoturW limits fiangas,Supports and Compoucnw:Pottery fabacmed according 1,MS5 SP-58. �b " ) MECHANICAL EQUIPMENT(PLAN VIEW) m� •0 6 ..,_...-...... zu EXECUTION 9 Hanger and.ippoa apphcadona and inatauau,n shall wmply will,Mss sr-69 am1 sr-s9-Inatan M1angea,aapp,a.,mampx and aua,hmwna as rep,aree m pinperly supp,th piping from r—1 MECHANICAL ROOFTOP EQUIPMENT(SHOWN ON PLAN VIEW) buildivg svucturc. L_J ' Hanger spacing shall as n minimam meet the UPC or local plumbing and mechanical codes. 0 y Egmpmem,npp,rtregairea fabricated atmcmal steel stand,to suspcud egwpmwtfrom eaucWre about or support equipment above door. =� MECHANICAL ROOFTOP EQUIPMENT(SHOWN ON ROOF LEVEL) �p L a 15091-DUCT INSULATION 'a1i�ry � GENERAL N a can,- ua ild,111,- l: hllnavcallame,pa,d anng,f25mless aimasm,k,eeveWpW rating ergo or less z 1-IECHANICAL EQUIPMENT IDENTIFICAVON �� u INSULATION MATERIALS LLB �z I-atio,It,tcnalsb ll be Mmml Ffi,o,BI nka Thermal hCIJefim Glass fibers bondW with a the—aft rosin Comply will,ASTM C 553,Type 11,wilh,.t facing end with 3 ill ser j k —fie—Id f KIM pap mfie-ng atom,orummum fail and vinyl hhn(FSK) W Field Applied laeketa w comply with AS"1 M C 921,'Iype L Alumimun Jacket Smooth finish O THERMOSTAT OR TEMPERATURE 5EN5OR d' ACCESBORI ES AND ATTACHMENTS W of WCId-Attached Anch,r Pi-and WCshea:Coppercoshed steel pillfm capacib,,diachage w,Iding and galvanized Vp dwaahct'. Q Adhus AtW 1 W Anal '1 nd Speed Washers Cied—i-d mast plat.,pin and wait,maoifautured for fl-b—,m an,t aid pieo with adheshe. Vapo,R a M Sri M all ro,,=.ded by msaiatim ulateCkd mm,ufaaumr. aJ r Du,r SYS I LM APPLICATIONS GRILLE & REGISTER SCHEDULE LL < [mutate the f.hewing plenum,and ducrsyutema: U _1 ripply-,ratio and,mam,-air d„tw,di. PLAN DESCRIPTION Mm MODEL FINISH REMAWS . Rou,d d g l ,pply outdoor and,energy recovery exhaust and revnn ducts ecCIW CODE and exp ca. Mabee I.Mm l fb bleeket,2 3/16"lhrck,0.75 IWII13 density,eve lay,,f T ram Repo,held applied jeekol,vapor 1 regtiircd MANUFACTURERS SEE O cal„ed xara expose,,itaoo,a or as omawise shown on me Dmwings,pmme,r„la appfiW wc,th,tigbt,liiminnm jwket ,,gl fil msmanon(mimmtmR81—Imim vane) CD CEILING DIFFUSER TITUS TDCA N Q 15815-METAL DUCTS STANDARD OTES SHEET METAL MATERIALS NOTES: W ofspec,mast hi thickness per SMACNA,packaged sod marked a.speafea in ASTM A 700.Duce pressure class m be 2••w.g.a,wnsveam of vnv boxes sits low pressme veils.6••­1, 1.CONTRACTOR SHALL VERIFY EXACT BUILDING CONSTRUCTION d CEILING V J _ u,d,—CfVAVb-C to—di—pCC--i.. TYPES a PROVIDE CORRECT FRAMES FOR ALL AIR DIFFUSION PRODUCTS SEALING MATERIALS AS REQUIRED.VERIFY ALL COLORS 6 FINISHES WITH ARCHITECT PRIOR TO m Joim and seam sealant one-Part,nonsag.soroeta-release-coring,polymaiaea bmyl aealano. � No sits rape ml,wea seal aluongimdinal and Van.veaejoinl,. SUBMITTAL.THE FOLLOWING MANUFACTURER'S ARE ACCEPTABLE W m o ' SUBSTITUTES PROVIDING THEY MEET THE REQUIREMENTS AS SCHEDULED: W DUCT CAPRI ATION NAILOR,CARJES,KRUEGER,METAL AIRE,TUTTLE e BAILEY,AND TITUS. calranized sheen steel•c9o'ia aceoraan,e vest SMACNA^Bvne)amh eonawaion shanaarda-Metal and Flexible^ 2.GRILLES,REGISTERS d DIFFUSERS INSTALLED IN ALL CEILINGS SHALL BE ^^ _1 m s SECURED AND/OR SUPPORTED IN ACCORDANCE WITH INTERNATIONAL 1..1. o v t+i ai HANGERS Sped AND SUPPORTS BUILDING CODE STANDARDS FOR SEISMIC DESIGN. < Z ai m Suppo6 systems ivdioeted in SMACNA"HVAC Dna Conshuaion Slaidmd.-Metal and Flexible." trl Seismicly brace per SMACNA"Sammie Rcshaint Design Grade"Imes)version. O To 0 0 i.NO]NCI 15820E DUCT ACCESSORIES N DAMPERS L,wpre..mpm nmdampaa.. bled lypeaprninx hl,nkingopeaWr DRAWING INDEX J? C,nvol Dampers Pmmlel blades 1br hw,posihon covvol,oppose,blades for modulating wmrol. Coumabld—d Reli,PDampers.Parallel blades and coumerbalanced SHEET NUMBER DESCRIPTION W TURNING VANES Fabricate turning Banes in aewrda„ee w,m SMACNA^Rune Dac(consfmttioa shanaam.-Metal and Flexible. MIPJ MECHANICAL COVER SHEET 7 C FLEXIBLE CONNECTIONS M40 HVAC FOURTH FLOOR PLANS L G Neoprene-coated flameproof fabric crimped into duct fringes for atlachmevt W Nutt and equipment. Flex Duct Insulated fax Por 6 w g with hits Maximum lrngdi of5 0"wiN no chary bends $ 9 INSTALLATIONOFDUCTWORKACCESSORIES 77 Install ductwork aocessories m accordance with manuf hirer's ingellalmn i—ions,with applicable pordons of doll of construction as shown in SMACNA Standard.,and in " CCeod..with rewgoized md—y paoheea W ensure that product,serve mh,idol f chon 1 F#17 531 15990-TESTING.ADJUSTING AND BALANCING !�- GENERAL The.quireme and procedures f total mechanical systems testing,adjusting and balancing(TAB)include measuring and eatabhshing the fluid quantities of mechanical systems as PROJECT DATE regorred W meet design spoeifewions and recording and reporting the resorts. 17013 6114 017 e; Tell,adjust and balance fie following meohansel systems' supply mr ay,tem,.allpre.anreange. BALANCE REPORT 2.Retum air systems. DRAWN CHECKED 3.Verify mmpamme control system wo od". AS MG QUALITY ASSURANCE DUE AT FINAL } Teat and Balance Engineers Qvmificanova An Independent consultmit ngi—W m the sWW in which the smi,e,arc to be performed and hevmg at least 3 years of aucoossfid TAB REVISED: Q experience,,pmjeas with requirement.and systems smular to those specified for this p,,jW Codes and Standards: # Description Date AABC"NafimeI Slmrda d,fa Taal S aWm Bet ao," 172 C F M MIN. 2.NEBB:"Nalional Envuee..Ed Balancing Bureau" PERFORMING TESTING,ADJUSTING AND BALANCING. Perform TAB procedures on each system identified in accordance wilb the detailed procedmea o.UiC d iv the ref enced standards. Ca RECORD AND REPORT DATA - Record all date obtained dmng TAB data galh,Ing m accordance with,Cod on the forms rerormveaded by,die enced standmds and as approval on sample report forms. _ DEMONSTRATION Training:Train the Owner',maintenance personnel on trouble-.hooting procedrtres M TAB procedures. END OF SECTION s. SHEET TITLE MECHANICAL COVER SHEET SHEET Lu 01 M1 .0 GENERAL NOTES p . ................ .. n �____.-. ... �� A AUTHORITY HIAVINTE A LOCAL C PATIENT --Ep�p--^^ 1 ..„ IGABLE STATE�LOCAL CS SCOPE SHALL COMPLY WITH ALL _°nm i t. 48 5RG 1, - i,t"' 3) CODES e ALL REQUIREMENTS OF THE NOS I 500 CFM B. CONTRACTOR TO REPAIR AND PATCH BACK ANY HOLES IN WALLS :I (TYP.OF 4) ICING THAT RESULT FROM DEMOLITION OR INSTALLATION OF MECHANICALF N p ry ABOVE ITEMS. '. o t9 C. WILL BEHHOWN A A ITEMS ICAL SIS NG D EMO PLAN DARKIDASHHEDN LINETYPE ANDTHE�AVAG; MTION UONLIE55 OTHERWISE NOTED ARE TO BE REMOVED MSG D. ON THE NEW HVAC PLAN THE EXISTING"VAC WILL BE SHOWN IN A 1 LIGHTER LINETYPE FOR CLARITY AND THE NEW HVAC WILL BE SHOUN A$A DARK LINE. E. PROVIDE SEISMIC RESTRAINTS FOR ALL EQUIPMENT,DUCTWORK t PIPING AS RECOMMENDED IN THE LATE5T EDITION OF SMACNA -�_. T 7 'SEISMIC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL EQUIPMENT." CONSULT LOCAL COPES FOR THE SEISMIC RATING OF Q THE BUILDING SITE. Of Q J 9A:v 2 F. VERIFY"EQUIPMENT REQUIREMENTS 4 COORDINATE WITH ALL OTHER W Q I r f TRADES AS NEEDED TO ENSURE THAT SERVICE 6 OTHER Z ILL. REQUIRED CLEARANCES ARE MAINTAINED. J G. SEAL ALL PENETRATIONS OF FIRE-RAYS ASSEMBLIES WITH U1. ! "s'tiV* - J APPROVED DRAWINGS. FIRE-RATED SYSTEM. REFER TO ARCHITECTURAL 22x16 i6x16 J I I > 5 t ~ -I 1,} I P � I I L H. FLEXIBLE DUCT RiIN-OUTS ARE LIMITED TO 5'-0"MAXIMUM LENGTH. (TY .) I y VERIFY FINAL LOCATION OF E DIFFUSERS,RGI5TER5 6 GRILLES WITH a m v n ARCHITECTURAL REFLECTED CEILING PLANS a ELECTRICAL y' � --- s 2 t 2 ( LIGHTING LAYOUT. N n w _..._t_.....� ki I - o ( �' - ---"--- J. ALL CEILING DI FFUSE"SHALL BE 4-WAY THROW UNLESS NOTED IOTHEW16E ON PLANS, -� �� -" ----- -- K vER FYFINAL LOCATION OF Y-STAYS HUMIDISTATS,AND SENSORS a -- WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION. i x .... ..,._ _ _ _ �61u �. _ - - - --- - - _. r - c � { - _ r.-... W - w a Lu U u ( R20) v \ � U 00 �— w J R FOURTH FLOOR HVAC PLAN — DEMOLITION PON, Q w W m �ro a Z (1 t LL � J�ai mm PATIENT I LIN TRUCK � KEY NOTES O > m o —"""" L REMOVE THERMOSTAT AND PATCH WALL. THERMOSTAT TO BE RELATED TO NEW SPACE. f n 'F 't � V - y E`f E 1i 2 OLISH DUCT AND FLEX DUCT. REMOVE SLOT DIFFUSER _ € l r `` DIRECTIONAL VANES FROM ALL SLOTS. uj C --- I .- -- 1 3. RELOCATED THERMOSTAT,CONNECT CONTROL WIRING TO t C�— .._ ..__ -. ( SAV-4065. 4 BALANCE RETURN SLOT T FM' o amm c J . 5 _._.:=_........ 4 - _a, 2oxisg^� #17 531 PROJECT DATE 17013 6/1412017 3 8 12 41 S®O GFM 1 4 DRAWN CHECKED sav-_ (TYP OF 4) AS MG YI y REVISED:Q 1( 2x ( 16x16' ( # I Description Dale 22xi6 -- 12"4 16x16 / Jill! - -N4010 - — — 12 4 CTYP) v E - - z _.. I I _ --------- ---- .. zr _ SHEET TITLE I HVAC FOURTH R20) FLOOR PLANS uj SHEET uj FOURTH FLOOR HVAC PLAN — DEMOLITION M4.0 L ABBREVIATIONS ONE-LINE DIAGRAM LEGEND POWER&CIRCUITING LEGEND COMMUNICATION LEGEND GENERAL ELECTRICAL NOTES ABBREV DESCRIPTION ABBREV DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION-SUBSCRIPT IDENTIFIERS MOUNTING J-BOX GENERAL NOTES: HT-CTR TYPE A AMMETER,AMPERE,AMBER M MUSIC SYSTEM CONTACT-NORMALLY OPEN WITH NEMA SIZE $ SINGLE CONVENIENCE RECEPTACLE U.N.O. U.N.O. 31. PROVIDE FIRESTOPPING FOR ALL FLOOR AND FIREWALL PENETRATIONS.SITE AF AMPERE FRAME MACH MACHINE INDICATED AS APPLICABLE VERIFY FIREWALL LOCATIONS OR DETERMINE FROM ARCHITECTURAL REFERENCE AFD ADJUSTABLE FREQUENCY MCC MOTOR CONTROL CENTER DUPLEX CONVENIENCE RECEPTACLE-SUBSCRIPT ID. PS NURSE CALL SYSTEM POWER SUPPLY +48" G PLANS.DEVICE BOXES ON OPPOSITE SIDES OF FIRE WALLS(1 HR AND 2 HOUR DRIVE MDC MOTORIZED DAMPER CONTACT-NORMALLY CLOSED WITH NEMA SIZE C -CLOCK HANGER TL-TWIST LOCK WALL CONSTRUCTION)SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF AT AFF ABOVE FINISHED FLOOR CONTROL S INDICATED AS APPLICABLE CR -CORD REEL WP-WEATHERPROOF NURSE CALL STATION: LEAST 24 INCHES.OUTLET BOXES SHALL BE OF STEEL CONSTRUCTION,NOT OVER ANN. ANNUNCIATOR VIED MEDICAL S -SURGE SUPPRESSION P A -MARQUEE SEE ARCH E 16 SQUARE INCHES IN SIZE,WITH NO MORE THAN 100 SQUARE INCHES OF TOTAL AS AMMETER SWITCH, MERC MERCURY VAPOR OVERLOAD RELAY HEATER (ALPHA NUMERIC DESIGNATION BY DEVICE/CONNECTION B -CODE BLUE STATION +54" E BOX OPENING FOR ANY 100 SQUARE FEET OF WALL,OR BE LISTED AND RATED FOR AMPERE SENSOR MH MANHOLE POINT INDICATES PANEL CIRCUIT;SEE PLAN NOTES) C -COMMUNICATION RECEPTACLE +16^ E USE IN FIRE WALLS. ASU AIR SUPPLY UNIT MMP MECHANICAL MONITORING �� MAGNETIC STARTER WITH NEMA SIZE INDICATED CC -CALL CANCEL BUTTON +54" E AT AMPERE TRIP PANEL �p_ OR(0- DOUBLE DUPLEX CONVENIENCE RECEPTACLE D -DUTY STATION +1^ A G2. CONTRACTOR SHALL VERIFY ALL ELECTRICAL DEVICE LOCATIONS.ESTABLISH ATC AUTOMATIC THROWOVER MO MOTOR OPERATOR r, CIRCUIT BREAKER,MAGNETIC TRIP ONLY,FRAME E -EMERGENCY TOILET PULLCORD STA. +42" E MOUNTING HEIGHTS BY COORDINATION WITH ARCHITECTURAL INTERIOR CONTROL MS MOTOR STARTER 100/M SIZE SHOWN,3-POLE UNLESS INDICATED OTHERWISE PEDESTAL CONVENIENCE RECEPTACLE-DUPLEX,SINGLE El -EMERGENCY SHOWER PULLCORD STA. +72" E ELEVATIONS,OR PER ELECTRICAL SPECIFICATIONS.MOUNT RECEPTACLES IN pNP� ATS AUTOMATIC TRANSFER MT MOUNT FACE UNLESS NOTED OTHERWISE ET -ELAPSED TIMER +54" C KNEE WELL,WHERE APPLICABLE,OR 4"ABOVE BACKSPLASH OR COUNTER WHERE Fhb 0Hy y SWITCH MTD MOUNTED — CIRCUIT BREAKER,THERMAL MAGNETIC TRIP SHOWN, DUPLEX CONVENIENCE RECEPTACLE-FIRE RATED M -MASTER STATION +18" B KNEE WELL IS NOT PRESENT.VARIATIONS SHOWN ON DRAWINGS. 400 3-POLE UNLESS INDICATED OTHERWISE ® FLOOR POKE-THROUGH MG -MEDICAL GAS MONITORING PANEL +54" J '- B BELL,BLUE P -BEDSIDE STATION +48" A G3. WIRING FOR"NORMAL","LIFE SAFETY",AND"EMERGENCY CRITICAL"CIRCUITS BC BARE COPPER N NEUTRAL \ SWITCH-CURRENT RATING INDICATED,3 POLE ®F DUPLEX CONVENIENCE RECEPTACLE(FLUSH IN FLOOR) P/S -PATIENT/STAFF EMERGENCY STATION +54" C SHALL BE ROUTED IN SEPARATE CONDUITS;WHERE WIRING FROM DIFFERING BKR BREAKER NA NON-AUTOMATIC 100 UNLESS INDICATED OTHERWISE S -STAFF STATION +1^ A SYSTEMS ENTER THE SAME ENCLOSURE,A SUITABLE BARRIER SHALL BE BLNKT BLANKET NC NORMALLY CLOSED 1 m m m$@ MULTI-OUTLET ASSEMBLY-LENGTH AS NOTED S/E -STAFF/EMERGENCY STATION +54" E INSTALLED IN THE ENCLOSURE FOR SYSTEM SEPARATION. sx,73b BOT BOTTOM NCJB NURSE CALL JUNCTION BOX ® FUSE-RATING INDICATED L -STAFF LOCATOR +48" E NIC NOT IN CONTRACT 225 300 RECEPTACLE-240V,1PH,AMPERAGE INDICATED CEILING G4. ALL CONDUITS SHALL CONTAIN AN INSULATED GROUND CONDUCTOR,MINIMUM C CONDUIT,CONTACTOR NL NIGHT LIGHT DRAWOUT CIRCUIT BREAKER,LOW VOLTAGE SIZE AS REQUIRED PER THE N.E.C. CB CIRCUIT BREAKER NO NORMALLY OPEN 30® RECEPTACLE-SPECIAL PURPOSE,AMPERAGE INDICATED �Q NURSE CALL MARQUEE AUDIO W/MUTE BUTTON +48" J CC CONTROL CABLE NP NAMEPLATE DRAWOUT FUSED SWITCH,MEDIUM VOLTAGE G5. THE MINIMUM SIZE CONDUCTOR SHALL BE#12 AWG COPPER,UNLESS OTHERWISE CE CONCRETE ENCASED (MOUNT WALL RECEPTACLES+16"AFF TO CENTER U.N.O.) (j NURSE CALL DOME LIGHT: NOTED. CONDUIT OFE OWNER FURNISHED �I� SURGE ARRESTER Z N -NURSE ALERT CEILING C CKT CIRCUIT EQUIPMENT EXPOSED CONDUIT AND CONDUCTORS Z -ZONE LIGHT CEILING C G6. ALL NEW 120 VOLT CIRCUITS SHALL HAVE A DEDICATED NEUTRAL,SIZED TO 0 I- CO CONDUIT ONLY(EMPTY) OL OVERLOAD RELAY (10 CAPACITOR-KVAR INDICATED NONE-DOME LIGHT +86" C MATCH PHASE CONDUCTOR,WHITE WITH TRACER. NEUTRAL TRACER COLOR _ M COMM COMMUNICATION ----------- CONCEALED CONDUIT AND CONDUCTORS SHALL MATCH THE PHASE CONDUCTOR COLOR. Q _ 00°0CD CORR CORRIDOR PAT PATIENT �OV METER WITH SWITCH-SCALE RANGE SHOWN � ROOM STATUS DOME LIGHT SEE PLAN C O (n iz O� CPT CONTROL POWER PAJB PAGING JUNCTION BOX SW 0_�500V CONDUIT DOWN G7. LINEWORK,WHERE SHOWN,INDICATES ANTICIPATED CONDUIT LAYOUT. J oD� TRANSFORMER PB PULL BOX,PUSH BUTTON AO ROOM STATUS ANNUNCIATOR PANEL(MASTER): SEE ARCH. I ROUTING OF CONDUIT SHALL BE SUCH THAT"MAIN TRUNK"CONDUITS SHALL BE J 0-06 CR CONTROL RELAY,CORD REEL SWITCH ��I� GROUND CONDUIT UP W D -DESK MOUNTED LOCATED ABOVE CORRIDOR SPACES AND NOT ROUTED THROUGH PATIENT LLI Q m-1* CRS COATED RIGID STEEL PC PHOTOCELL W -WALL MOUNTED SPACES. z LL_ a)M CONDUIT PMP POWER MONITORING PANEL wv.� TRANSFORMER,SECONDARY VOLTAGES,PHASE AND CONDUIT STUBBED AND CAPPED Q CO CT CURRENT TRANSFORMER PMR PHASE MONITORING RELAY m °r RATING AS SPECIFIED g E SINGLE RED LENS +48 E ROOM STATUS STATION: G8. PROVIDE AND COORDINATE DEMOLITION OF EXISTING ELECTRICAL REQUIRED J z OCD MAJOR ELECTRICAL COMPONENT OR DEVICE CUH CABINET UNIT HEATER PNL PANEL - OE - " FOR AREA OF CONSTRUCTION WITH OWNER AND IN WALLS/CEILINGS AS SHOWN LL.I d (V ® j PNLBD PANELBOARD MCC-A NAME OR IDENTIFYING SYMBOL AS SHOWN PC -PULLCORD +48" E ON ARCHITECTURAL DEMOLITION SHEET(S).SPECIFIC ELECTRICAL DEMOLITION J IDS DIRECT BURIED CONDUIT PROJ PROJECTION GF 25A GROUND FAULT RELAY WITH C.T. NONE-4-SWITCH +qg^ E MAY NOT BE SHOWN. MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING DEVICES O DC DIRECT CURRENT PS PRESSURE SWITCH 01 MAJOR ELECTRICAL COMPONENT OR DEVICE EXISTING WHICH ARE LOCATED IN UNDISTURBED PORTIONS OF THE FACILITY UNLESS DISP DISPENSER PT POTENTIAL TRANSFROMER OR INSTALLED UNDER SEPARATE CONTRACT- SURGERY PATIENT STATUS ANNUNCIATOR: OTHERWISE NOTED. DEVICES OR HARDWARE SALVAGED FROM DEMOLITION DIV DIVISION PVC POLYVINYL CHLORIDE 480:120V NAME OR IDENTIFYING SYMBOL AS SHOWN. 'I'�� D -DESK MOUNTED +16" G PROCESS AND REUSED IN REMODEL CONSTRUCTION ARE ONLY SHOWN IN THE DWG DRAWING (3) POWER TRANSFORMER,SIZE AND NUMBER M -WALL MOUNTED MASTER +86" G NEW RELOCATED PORTIONS. CD R RED,RELOCATE INDICATED ON DRAWINGS 1N(B) BRANCH CIRCUIT PANEL BOARD W -WALL MOUNTED +86" E 00 E EMERGENCY RCPT RECEPTACLE ON. OFF G9. SCREENED DEVICES ARE EXISTING TO REMAIN,UNLESS OTHERWISE NOTED. EF EXHAUST AIR FAN REFRIG REFIGERATOR SELECTOR SWITCH MAINTAINED CONTACT TTC TELEPHONE TERMINAL CABINET PATIENT ARRIVAL STATION: (FOR REFERENCE). ELEC ELECTRIC RGS RIGID GALVANIZED STEEL ~ �q A -ANNUNCIATOR(CORRIDOR LIGHT) CLG E G10. "R"ADJACENT TO A DEVICE INDICATES AN EXISTING DEVICE TO BE RELOCATED. n/ ELEV ELEVATOR RM ROOM TJB TERMINAL JUNCTION BOX CC -CALL CANCEL SWITCH 48" E EMERG EMERGENCY RMS ROOMS TDR I -RECEPTION AREA STATION(INDICATING) +48" E EO ELECTRIC OPERATOR RMSQ ROOM MEAN SQUARE T� G11.WORK WITHIN THIS FACILITY SHALL BE CLOSELY COORDINATED WITH SLHS IN ETM ELAPSED TIME METER IRS RIGID STEEL CONDUIT or TIME DELAY RELAY CONTACT(TIME ACTION INDICATED) (20F) 30 DISCONNECT SWITCH,SIZE INDICATED,FUSED 3-POLE,UNLESS INDICATEDORDER NOT TO DISRUPT OPERATION OF FACILITIES.COORDINATE ALL WORK ui OTHERWISE.SIZE FUSE AS NOTED INTERCOM STATION:IC EWC ELECTRIC WATER COOLER RT REMOTE TELEMETRY �xTD� OR REQUIRED(NF INDICATES NON-FUSED). W D -DESK MOUNTED +16" E WITHIN TENANT SPACES AND OUTAGES WITH SLHS. EXST EXISTING RVNR REDUCED VOLTAGE TQ W -WALL MOUNTED +1^ G NON-REVERSING REMOTE DEVICE 2 CONTACTOR,MAGNETIC,NEMA SIZE INDICATED S -SUBSTATION +5q^ G12. FOR KEY TO PANEL CIRCUIT SHORTHAND,SEE POWER PLANS. 7 FDR FEEDER RVR REDUCED VOLTAGE L F,FU FUSE REVERSING 0 LIGHTING CONTACTOR,CURRENT RATING INDICATED; H PA LOUDSPEAKER HORN(WALL-SURFACE MOUNT) G13. EXISTING INFORMATION IS BASED ON ORIGINAL DESIGN DRAWINGS AND/OR 1 1 H 1 A 30© PA -PAGING SYSTEM +90" E LIMITED SITE VERIFICATION. FIELD VERIFY ACTUAL FIELD CONDITIONS. ui FIX FIXTURE �+ FOR NUMBER OF POLES SEE,CONTROL DIAGRAM � FLR FLOOR SA SURGE ARRESTOR — o G14. PROVIDE NEW TYPEWRITTEN PANELBOARD DIRECTORIES WITH REVISED LOAD v FLUOR FLUORESCENT SC SPEED CONTROL SELECTOR SWITCH-MAINTAINED CONTACT 10 WOUND-ROTOR MOTOR,HORSEPOWER HP INDICATED (2) CONE TYPE SPEAKER: FVNR FULL VOLTAGE SH SPACE HEATER c CHART IDENTIFIES OPERATION: ( ) ®°W (2) -PAGING ZONE(NUMERICAL,IF READ) DESCRIPTIONS. ` 1 NON-REVERSING S/N SOLID NEUTRAL NONE-SINGLE CONE;PAGING AND MUSIC RE-CLG G J POSITION D -DUAL CONE RE-CLG G G15. PROVIDE MATERIALS AND WORKMANSHIP AS SPECIFIED UNDER THE ST.LUKE'S FVR FULL VOLTAGE REVERSING SPD SPEED 5 MOTOR,SQUIRREL CAGE INDUCTION,HP INDICATED LL CKT. HAND OFF AUTO STANDARD SPECIFICATIONS,DATED NOVEMBER 11,2010,UNLESS OTHERWISE SST STAINLESS STEEL X-CLOSED CONTACT W -SINGLE CONE;WALL-SURFACE MOUNTED +90" G NOTED ON THIS PLAN. FOR REVIEW OF DOCUMENTS,SEE 1 X O O V -INTEGRAL VOL CONTROL RE-CLG G G GREEN,GROUND ST SHUNT TRIP O-OPEN CONTACT STARTER MAGNETIC NEMA SIZE INDICATED,SEE OWNER'S CONSTRUCTION MANAGER. GALV GALVANIZED STA STATION 2 O O X 2® CONTROL DIAGRAM A -REMOTE VOLUME CONTROL RE-CLG G LL GFI GROUND FAULT SV SOLENOID VALVE M -MUSIC SYSTEM RE-CLG G INTERRUPTER SW SWITCH PUSH-BUTTON SWITCH,MOMENTARY CONTACT, 2 14L COMBINATION(FUSE OR CIRCUIT BREAKER AS INDICATED) NC -NOISE CANCELLATION RE-CLG G O Q GFR GROUND FAULT RELAY SWBD SWITCHBOARD NORMALLY OPEN I MAGNETIC STARTER,NEMA SIZE INDICATED,SEE GND GROUND SYM SYMMETRICAL PUSH-BUTTON SWITCH,MOMENTARY CONTACT, CONTROL DIAGRAM A VOLUME CONTROL-WALL MOUNTED(FOR +54" E GENERAL POWER PLAN NOTES: w oLo SPEAKERS OF ROOM OR AS INDICATED) /n g H HIGH SPEED,HORN, T THERMOSTAT NORMALLY CLOSED ® CONNECTION POINT TO EQUIPMENT SPECIFIED,FURNISHED, GP1.DEVICE BOXES SHALL NOT BE MOUNTED BACK-TO-BACK IN WALLS,UNLESS V/ HOWLER TB TERMINAL BOARD AND INSTALLED UNDER OTHER SECTIONS,UNLESS O TELEVISION DEDICATED OUTLET(SINGLE CABLE) +72" E OTHERWISE APPROVED BY OWNER. s HH HANDHOLE TC TIME CLOCK,TIME CLOSE 600:5 CURRENT TRANSFORMER,SIZE AND NUMBER OTHERWISE NOTED.RACEWAY,CONDUCTOR AND 1 c HID HIGH INTENSITY TD TEMPERATURE DETECTOR INDICATED ON DRAWINGS CONNECTION IN THIS SECTION. GP2.MOUNT MULTIOUTLET ASSEMBLY AND GENERAL RECEPTACLES(COUNTERTOPS DISCHARGE RELAY (3) N 2 TELEPHONE/DATA OUTLET: WITH KNEE SPACE BELOW):16"ABOVE FLOOR.(GROMMETS WILL BE PROVIDED IN <>- L u°0 HPS HIGH PRESSURE SODIUM TOR TIME DELAY RELAY AS ABOVE: # -NUMBER OF CABLES +16" E COUN�� TER TOP BY OTHERS FOR ACCESS TO OUTLETS). "S HVAC HEATING,VENTILATING& TJB TERMINAL JUNCTION BOX (p� INDICATING LIGHT,PUSH-TO-TEST,LETTER ® CONNECTION TO FIRE/SMOKE DAMPER F -FIRE FIGHTER'S TELEPHONE JACK +48" E w 912 I W -WALL MOUNTED(1-CABLE) +48" E AIR CONDITIONING TM TIME RELAY ��%CC INDICATES COLOR D P -PAY TELEPHONE(1-CABLE) +48" E GP3.PROVIDE HOSPITAL GRADE RECEPTACLES IN ALL AREAS,UNLESS OTHERWISE 1 m o N J t o HW HOT WATER TO TME OPEN NOTED. INDICATING LIGHT-LETTER INDICATES COLOR L -WIRELESS LAN HUB(1-CABLE) CLG E 1 o 0 HW DISP HOT WATER DISPENSER TR TIMER-REPEAT CYCLE O ORE GENERAL CONTROL OR WIRING DEVICE. LETTER SYMBOLS J '� TSP TWISTED SHIELDED PAIR A-AMBER G -GREEN INTERRUPTING CAPACITY TST TWISTED SHIELDED TRIAD B-BLUE R -RED K +q OR ABBREVIATIONS INDICATE TYPE OR DEVICE NAVICARE KEYPAD INPUT STATION g" U K IC �< =N &C NSTRUMENTATION AND TTC TELEPHONE TERMINAL C-CLEAR W-WHITE ❑T STEP DOWN TRANSFORMER GENERAL LIGHTING PLAN NOTES: �� .. ... CONTROL CABINET & ANALOG CLOCK SYSTEM +g0" J $N N AHu (SEMIFLUSH WALL MOUNTED) IJB INTERCOM JUNCTION BOX TTJB TELEPHONE JUNCTION BOX MECHANICAL UNIT IDENTIFIER,EXAMPLE SHOWN GLi. REFER TO ARCHITECTURAL DRAWINGS REFLECTED CEILING PLANS FOR EXACT ILLUM ILLUMINATOR TYP TYPICAL SECURITY LEGEND O ELT ELAPSED TIMER A LIGHT FIXTURE LOCATION. IMC INTERMEDIATE METALLIC TX TRANSFORMER M MOTION DETECTOR FOR DOOR CONTROL CONDUIT SYMBOL DESCRIPTION IMP O.R.ISOLATION SYSTEM MONITORING PANEL +11. J GL2. ALL EMERGENCY AND LIFE SAFETY FIXTURES SHALL BE UNSWITCHED,EXCEPT ICNAD INCANDESCENT UC UNDER CABINET OP DOOR ACTIVATING PUSHPLATE/SENSOR(48+AFF TO CENTER U.N. .) WHERE SWITCHING IS INDICATED BY LINEWORK TO A SWITCH. `♦•^' INST INSTANTANEOUS UH UNIT HEATER ❑S q SECURITY ALARM POINT CONTACT "FLASHER"SYSTEM: v IPCO IDAHO POWER COMPANY UVR UNDER VOLTAGE RELAY PUSH-BUTTON STATION. FOR TYPE PUSH BUTTON GL3. SWITCHES WITH NO SUBSCRIPT CONTROL ALL LIGHTING WITHIN THE SAME ROOM, U.N.O. UNLESS NOTED OTHERWISE ❑S C SECURITY PROXIMITY CARD READER(+48"AFF) PB REQUIRED,SEE CONTROL DIAGRAMS T m AF STAFF ALERT ANNUNCIATOR CEILING J UNLESS OTHERWISE SHOWN OR NOTED. w Q J,J-BOX JUNCTION BOX U.O.N ❑S E SECURITY ELEVATOR LOCKOUT CONTROL OO THERMOSTAT OR HUMIDISTAT(+54"AFF TO CENTER U.N.O.; �'P PULL CORD STATION +42" B GL4. CIRCUITING LINEWORK MAY BE SHOWN FOR CLARITY OF SWITCHING AND z K KEY INTERLOCK V VOLTMETER,VOLT PROVIDE 1/2"C EMPTY,STUB-UP TO CEILING SPACE) CIRCUITS.FIELD DETERMINE OPTIMUM RACEWAY AND NECESSARY VFD VARIABLE FREQUENCY ❑S ROOM DOME LIGHT CLG g p SECURITY PANIC BUTTON(MOUNT UNDER COUNTER) VERIFY LOCATION WITH MECHANICAL CONTRACTOR. IF CONDUCTOR COUNT TO ACHIEVE INTENDED SWITCHING AND CIRCUITING. L LIGHTING CONTACTOR, DRIVE LOW SPEED VS VOLTMETER SWITCH SECURITY DOOR CONTACT SM MANUAL MOTOR STARTER SWITCH AV2 AUDIO VISUAL OUTLET LOS LOCKOUT STOP PUSH D-INTEGRAL TO DOOR HARDWARE OR HINGE,SEE GENERAL COMMUNICATION PLAN NOTES: BUTTON W WATT JL ARCHITECTURAL DOOR HARDWARE SCHEDULES. p LT FLEX LIQUID TIGHT FLEX WC WATER COOLER GC1. ALL CONDUIT FOR COMMUNICATIONS SYSTEMS SHALL BE 3/4"MINIMUM UNLESS ,r St Lukes CONDUIT WH WATER HEATER S-SURFACE MOUNTED CONTACT/MAGNET COMBO WITH ELECTRICAL DISTRIBUTION EQUIPMENT IDENTIFICATION OTHERWISE NOTED. LTG LIGHTING WHD WATTHOUR DEMAND METER TAMPER RESISTANT METAL-CLAD PIGTAIL. l r # 17-531 LR LATCH RELAY WP WEATHERPROOF R-FULLY RECESSED CONTACT/MAGNET COMBO INSTALLED IN 3 N L B DP(H1) GC2. CONTRACTOR SHALL ONLY INSTALL CONDUIT AND JUNCTION BOXES FOR THE WRMR WARMER DOOR FRAME HEADER/TOP OF DOOR. SERVICE AREA: FOLLOWING COMMUNICATIONS SYSTEMS PER THE COMMUNICATION DRAWINGS: # NUMBER DATAITELEPHONY,NURSE CALL,AND PAGING.WIRING AND DEVICES SHALL BE PROJECT DATE XFMR TRANSFORMER (Z) =CENTRAL UTILITY PLANT (H1)=DIAGNOSTIC&TREATMENT- INSTALLED BY THE QUALIFIED CONTRACTORS FOR THESE SYSTEMS.ALL OTHER SOO SECURITY DOOR LOCK CONNECTION(LOCK BY OTHERS) (N) =INPATIENT TOWER- DIAGNOSTIC #1) SYSTEMS SHALL BE PROVIDED COMPLETE,UNLESS OTHERWISE NOTED. 693462.V3.05 06/14/2017 D-INTEGRAL TO DOOR HARDWARE OR HINGE,SEE NORTH (H2)=DIAGNOSTIC&TREATMENT- LIGHTING&SWITCHING LEGEND ARCHITECTURAL DOOR HARDWARE SCHEDULES. (0) =MEDICAL OFFICE BLDG (ELEC SERVICE#2) GC3. MOUNTING HEIGHTS AS INDICATED UNLESS OTHERWISE NOTED ON DRAWN CHECKED SYMBOL DESCRIPTION-SUBSCRIPT IDENTIFIERS S-ELECTRIC STRIKE IN DOOR FRAME LATCH. (11) =MSTI(ELEC SERVICE#1) MOUNTING REFERENCE: ARCHITECTURAL DETAILS.CONFIRM ALL HEIGHTS NTH OWNER PRIOR TO CLG JH �_� M-MAGNETIC LOCK ON DOOR FRAME HEADER. (12) =MST( I ELEC SERVCE#2) HT-CTR-MOUNTING HEIGHT TO CENTER INSTALLATION. r O-01 POLE MOUNTED FIXTURE EQUIPMENT: RE-CLG-MOUNTING RECESSED IN CEILING Q SECURITY MOTION SENSOR-ARROW INDICATES ENSING IN ALL DIRECTIONS MCC =MOTOR CONTROL CENTER SWBD =SWITCHBOARD GC4. CONTRACTOR SHALL INSTALL 314"CONDUIT FROM OUTLET BOX TO NEAREST REVISED S DIRECTION OF SENSING;360"INDICATES DP =DISTRIBUTION PANELBOARD (BLANK)=PANELBOARD ACCESSIBLE SPACE IN CORRIDOR CEILING AND STUB OUT FOR TELEPHONE, N CEILING MOUNTED FIXTURES OM S SWGR=SWITCHGEAR PDU =POWER DISTRIBUTIO TELEVISON AND COMPUTER DATA COMMUNICATIONS SYSTEMS CABLES. BW =BUSWAY UNIT JUNCTION BOX TYPES: CABLES NOT ENCLOSED IN CONDUIT SHALL BE SUPPORTED BY CABLE RING LUMINAIRES IS =ISOLATION POWER PANEL UPS =UNINTERRUPTIBLE 6"-12"ABOVE ACCESSIBLE CEILING,8'ON CENTER,MAXIMUM AND THE EXISTING WALL MOUNTED FIXTURES (SEE LUMINAIRE SECURITY CAMERA,PTZ-PAN,TILT,ZOOM POWER SUPPLY A -4-GANG x 3 112"DEEP CABLE TRAY SYSTEM. SCHEDULE FOR TYPE) B -4"SO x 2 118"DEEP W/1-GANG PLASTER RING TRACK MOUNTED FIXTURE FS-M-1 SECURITY MONITOR AND MULTIPLEXER SEQUENTIAL LETTER IDENTIFIER(A,B,C,ETC.): C -4"SO x 3 1/2"DEEP W/2-GANG PLASTER RING GC5. CONDUIT SYSTEMS SHALL BE IDENTIFIED BY DIFFERENT COLOR PAINT,AS w O(I�� (ALL EQUIPMENT SHARING THE SAME LOCATION AND POWER TYPE WILL D -4"SO x 2 1/8"DEEP FOR CONVENIENCE RECPETACLE DIRECTED BY OWNER,ABOVE ACCESSIBLE CEILINGS AND WHERE EXPOSED ®E �, OE EMERGENCY FIXTURES SCS SECURITY CONTROL,BATTERY OPERATED BE ASSIGNED A UNIQUE ALPHABETIC IDENTIFIER) AND BOTH"SO--GANG PLASTER F RING TELEVISION CABLE MIN.APART. IN UNFINISHED SPACES. SHEETTITLE Kai dl--, (BY OTHERS,SHOWN FOR REFERENCE ONLY) GC6. CONDUIT STUBBED OUT IN CEILING SPACE SHALL BE NO MORE THAN 6"-12" 1Zt�' VOLTAGE LEVEL: E -4"SO x 2 118"DEEP W/1-GANG PLASTER RING ABOVE DROPPED CEILING. MOUNTING HEIGHTS SHALL BE AS INDICATED ELECTRICAL ® EXIT LIGHT SINGLE FACE(SEE LUMINAIRE SCHEDULE) REX D REQUEST TO EXIT SIGNAL DEVICE L=LOW(208Y/120 VOLT) H=HIGH(480Y/277 VOLT) F -7 3/4"W x 10"H x 2 3/4"DEEP UNLESS OTHERWISE NOTED ON ARCHITECTURAL DETAILS.CONFIRM ALL 1 D-INTEGRAL TO DOOR HARDWARE OR HINGE,SEE G -FURNISHED BY SPECIAL COMM.SYSTEMS CONTRACTOR HEIGHTS WITH OWNER PRIOR TO INSTALLATION. > COVER EXIT LIGHT DUAL FACE(SEE LUMINAIRE SCHEDULE) ARCHITECTURAL DOOR HARDWARE SCHEDULES. POWER TYPES: H -4"x 3 l/2"DEEP W/1-GANG PLASTER RING > SHEET N=NORMAL M=EMERGENCY MECHANICAL I -16"W x 16"H x 4"DEEP GC7. ALL DATA/TELEPHONY STATION CABLES FOR OUTLETS SHALL BE ROUTED 7 EXISTING LIGHT FIXTURE-FOR REFERENCE ONLY P-PASSIVE INFRARED DETECTOR MOUNTED ABOVE DOOR E=EMERGENCY L_LIFE SAFETY J -AS SPECIFIED/REQUIRED FROM THE OUTLET TO THE OF FOR THAT FLOOR,UNLESS OTHERWISE NOTED. uJ FRAME.PROVIDE J-BOX TYPE W HORIZONTALLY MOUNTED C=EMERGENCY CRITICAL U=UNINTERRUPTIBLE/UPS K -4"SO x 2 118"DEEP W/2-GANG PLASTER RING X®R EXISTING LIGHT FIXTURE RELOCATED 6"ABOVE DOOR FRAME. GC8 FWHERE ROM THE INDIOUTCATED, T TELEVISION THT CABLES FOR TTER FOR THAT FLOOR. ROUTED \ S. LOWER CASE SUBSCRIPT LETTER IDENTIFIES LOCATION: S SECURITY KEYPAD SITE P=PENTHOUSE S= WN a COMMON SWITCH AND LUMINAIRE CIRCUIT ❑K B=BASEMENT #=FLOOR NUMBER fto SHEET S WALL SWITCH(+48"AFF TO CENTER U.N.O.) NOTE: NONE SINGLE POLE K -KEY OPERATED SAP SECURITY ALARM PANEL FOR TRANSFORMERS,AUTOMATIC TRANSFER SWITCHES,AND MANUAL } 2 -DOUBLE POLE LV-LOW VOLTAGE TRANSFER SWITCHES,IDENTIFICATION SHALL BE AS FOLLOWS: 3 -THREE WAY OS-OCCUPANCY SENSOR TRANSFORMERS: 4 -FOUR WAY P -PILOT LIGHT TX-'LOAD IDENTIFICATION',WHERE TX=TRANSFORMER, ' E 1 .0 B -SWITCH BANK WP-WEATHERPROOF AND'LOAD IDENTIFICATION'IS DEFINED ABOVE. ui D -DIMMER GENERAL LEGEND NOTE: EXAMPLE:TX-3NLBDP(H1) IC -INTENSITY CONTROL THIS IS A STANDARD LEGEND SHEET.SOME SYMBOLS OR TRANSFER SWITCHES: OS OCCUPANCY SENSOR,CEILING MOUNTED, ABBREVIATIONS MAY APPEAR ON THIS SHEET AND NOT ON THE PLANS. ATS-'LOAD IDENTIFICATION',OR MTS-'LOAD IDENTIFICATION';WHERE Q DUAL TECHNOLOGY ATS-AUTOMATIC TRANSFER SWITCH;MTS=MANUAL TRANSFER SWITCH EXAMPLE:ATSI3NLBDP H1 NOTE F1, TYPICAL t i LiONP� FIRE ALARM PLAN NOTES: c` ��tibe 2Y 10G - - - - - - F_ _-_ (FOR LEGEND AND GENERAL NOTES,SEE W o 111 SHEET E1.0;FOR LOCATION PLAN,SEE THIS = i SHEET) III F1. RETAIN AND PROTECT EXISTING FIRE - ALARM SYSTEM DEVICES. -0PV � N4010 30 �IIII I � 0 0 'n � - - o 0 10J ----------- - -, O to izoM 0_' J m u9 J x 0-a _u* I I I I W � Z_ I¢i 00 aSch J Z o0 w amN J O N OFIRE ALARM PLAN 1/8"=V-0" 00 4TH FLOOR ELECTRICAL FIRE ALARM LEGEND w ROOM;LOCATION OF PANELS 4NLD(N),4NLE(N), -------- MULTIPLE DEVICES OF SAME TYPE(ON RISER DIAGRAM) z 4CLC(N),4LLA(N) FAS W FIRE ALARM SYSTEM ❑F FAS MANUAL PULL STATION(+48 AFF TO CENTER) W o U FIRE SPRINKLER WATER FLOW BELL Provide alarm plans to the Twin Falls Fire Department for pp FAS PHOTOELECTRIC SMOKE DETECTOR p approval.Electrical permit shall be pulled through the Twin Falls u-U j Building Department. ID FAS IONIZATION SMOKE DETECTOR 00 ©� p FAS HEAT DETECTOR FAS PHOTOELECTRIC DUCT SMOKE DETECTOR ui Q (X) FAS ADDRESSABLE CONTROL/RELAY MODULE. (X)INDICATES — _ QUANTITY. �I m S x) FAS ADDRESSABLE INPUT MONITOR MODULE. (X)INDICATES W IM/ QUANTITY. I ;-�g o� m FAS STROBE LIGHT,WALL MOUNT(+80"AFF TO BOT.I;(X�OF _�'- /� x J e INDICATES CANDELA RATING IF GREATER THAN MINIMUM 15, '^ =A o 99 LOCATION OF EXISTING - vJ wm 4TH FLOOR COMM.IDF 0. - � FAS STROBE LIGHT,CEILING MOUNT AND SECURITY HEAD END EQUIPMENT H FAS SPEAKER,WALL MOUNT(+80"AFF TO BOT.); " �� W INDICATES HIGH SPL SPEAKER VERSION,TYPICAL ` / 14 FAS SPEAKER,CEILING MOUNT S / LOCATION OF m EXISTING FIRE W ALARM PANELS FAS SPEAKER/STROBE LIGHT COMBO,WALL MOUNT(+g0"AFF TO 7 C 2.1 FAS SPEAKER/STROBE LIGHT COMBO,CEILING MOUNT WP (SUBSCRIPT)WEATHERPROOF JL�+ AMP FAS AMPLIFIER ���7t LUke�S d PROJECT LOCATION CP FAS NOTIFICATION CIRCUIT/AUXILIARY POWER SUPPLY F # 1 7-531 ® ELECTROMAGNETIC DOOR HOLDER PROJECT DATE d / / © _ "� 693462.V3.06 06/14/2017 INTERPOSING RELAY/CONTACTOR. COIL VOLTAGE AS REQUIRED. d WIRE CONSTANTLY ENERGIZED OR'FAIL SAFE'. DRAWN CHECKED FIRE ALARM CONTROL UNIT CLC JH O d d �I FAC FIRE ALARM CONTROL PANEL N REVISED YI NOTIFICATION CONTROL PANEL FIRE ALARM ANNUNCIATOR O .� I I. ISO FAS SLC ISOLATION MODULE Z SHEETTRLE _� FIRE ALARM INDICATING LIGHT(RECESSED IN CEILING) I I b Ors 'TS'INDICATES INTEGRAL TEST/RESET SWITCH FIRE b b b ®D FIRE/SMOKE DAMPER CONNECTION POINT ALARM PLAN LLI LLI N SHEET FOURTH FLOOR LOCATION PLAN - INPATIENT TOWER U NTS w E6 .0 Q z oy F ^o"bQ 2r a z NOTE L3 ,J SZ O�2 COMch Software Version 4.0.5.4 Interi — — — — — — — — — — — — Interiorr Li htin Com liance Certificate I I 10G -�- -� - - - - -'I LIGHTING PLAN NOTES: I o Project Information (FOR LEGEND AND GENERAL NOTES,SEE SHEET E1.0; Energy code: 2012IECC ----------- FOR LOCATION PLAN,SEE SHEET E6.0) Q 001.000 Project Title: St.Luke's Magic Valley Medical Center New Hospitalist Office __ ________ __ J OD� Project Type: Alteration July III L1. GENERAL NOTE:CIRCUITS SHALL BE ROUTED TO PANELS w J p-a Lo do is x ACCORDING TO SCHEDULE SHOWN IN POWER PLAN NOTES, z LL CO OCI) conswcvon s9a: ownenAgem: Deeigrwnconhacmr: --- x a Ir--i---- b -S=-- {T--- - SHEET E9.0. 'N_ ' au Pole Line Road Jeff Hull John Hatten N401 R J z o 0 Twin Falls,ID 83301 St.Luke's Health system CH2M HILL LLf — d 0(V Boise.Bannock street 322 Eas[Front Sbee[ IF >F LL x - NE32-- a- F L2. REMOVE CONNECTION FROM EXISTING LIGHTING FIXTURES Boise,IBnnTc2 322SuiteEast --1----i---T----- T-- LU Boise,3-83702 - - � i IN HOSPITALIST ROOM TO LIGHTING CONTROL SYSTEM. 0 jonn.nateen®chzm.com _ __ ___ CONNECT TO NEW SWITCHES AND OCCUPANCY SENSOR FOR 20a-393-62a3 a - ---I - CONTROL AS SHOWN. Allowed Interior Lighting Power �� _ _ _ _ _ _ ____�___ L3. OCCUPANCY SENSOR SHALL CONTROL ALL LIGHT FIXTURES 00 A e c D __ -40- BOI'I -------* x Ir 1E -- � __ III IN ROOM. (rt2J watle/rtz (Bxc) I �—Fb i{0 L4. GENERAL NOTE:WHERE CIRCUITING LINE WORK AND Area Category Floor Area Allowed Allowetl Wafts a �J- JUNCTION BOXES ARE NOT SHOWN,PROVIDE SIMILAR TO 1-Hospitalist(Common SpaceTypesOlfice-Endoaetl) Ono 1.10 4e4 COMPARABLE SPACES.CIRCUIT TO PANELBOARD AS W Tclal Allowetl Weda= 464 INDICATED,TYPICAL. Proposed Interior Lighting Power L6 - - - - - - A B c D e NO __ L5. REFERENCE NOTE:WALL MOUNTED HAND SANITIZERS ARE Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ a of Fixture (c x o) _ TO BE MOUNTED A MINIMUM OF 1'-0"CLEAR OF ALL Fixture Fixtures Watt. ELECTRICAL SWITCHES AND RECEPTACLES. Hosnaalist I Common Soacn TVoes'Office-enclosed 440 so(11 Unear Fluorescent 1:X:Existing light fim-M*T5 HO 39W:EIect,oric: 1 6 39 234 L UJ LED 1:R2:2'x2'Volumetnc:Other 1 4 35 140 — — — — — — — — — — — L6. CONNECT TO EXISTING 120 VOLT,NORMAL POWER W U Total Proposed Wads= 374 LIGHTING CIRCUIT.FIELD VERIFY CIRCUIT NUMBER.Interior Lighting PASSES U J NOTE L2,TYPICAL LL Q Interior Lighting Compliance Statement 1 f / 1 Compliance Statement:The proposed interior lighting alteration submitted protect represented In this The proposed e consistent calm the L.L`J building plans,been designed and Omer calculations submitted with this permit application.The and o co Interior lightingany O_ systems have been ry requirements to meet the 20 the IECC Inspection is In COMcheck Version 4.0.5.4 and to comply with any applicable mandatory req I1remen[s listed In the Inspectlpn C ISllst. Q Joti NA+f6 e.E. /L �b 7 177 W Name-Title Slgnatur oate r rn vJ Q Wms N J �„ LIGHTING PLAN Q =� Project Title: St.Luke's Magic Valley Medical Center New Hospltallst Office Report dale:06/06/17 m N t Data filename:PASt Lukas Regional Medical Center\693462HUMMEL\693462 V3-Magic Valley-lemme1V3.01 Page lot 6 1/4"-1-O O> H c- MV Hospltallst OHlce\Electrical\Hospltallst Office ComCheck.cck n W Q Z5 ;FSt Luke's l r # 17-531 LUMINAIRE SCHEDULE 513 012 01 7 TYPE MANUFACTURER CATALOG NUMBER LAMPS WATTAGE VOLTAGE MOUNTING COMMENTS PROJECT DATE 693462.V3.05 06/14/2017 R2 LRFDNN(A_T,DAY-BRIE HEWLLIAMS,NETALUX,HJBBELL) 2RR2 33L EZ1 LPS40 LED INCLUDED 35 120 RECESSED VOLU ETRIC LIGH ING;ZxZ LED,DIMMABLE NOTE4 DRAWN CHECKED NOTES: CLC JH r 1.GENERAL NOTE DESIGN IS BASED ON FIRST NAMED MANUFACTURER THEALTBRNATE MANUFACTURERS MAY SE ACCEPTABLE SUBJECT TO COMPLIANCE O WITH THESPEOFI®REOUIRBAENTS,MODA NUMBER TYPE AND'ORCATALOG NUMBER IN REVISED 2.GENHRAL NOTE CONTRACTOR SHALL PROVIDE REDtdRED FIXTUREO1ANTR16,INSTALLATION FEATURES,ANDCOORDI ATEALL FIXTURE MOUNTING ACCESSORIES. ♦V 3.GEN87AL NOTE REFER TO ARCHITECTURAL REFLECTED CEILING PLANS,ELEVATIONS,AND DETAILS,FOR SPECIFIC MOUNTING LOCATIONS,HEIGHTS,AND OTHER RL-0UIREIVEIWS. 4.PROVIDESWITCH CONDUCTORS FOR DIVINING IN ACCORDANCE WT(H MANUFACTURERS INSTRUCTIONS. r W J SHEETTITLE LIGHTING PLAN W_ W SHEET w E7 .0 Q 5` py a tiP i POWER PLAN NOTES: a NOTE P5 Klill 2n IFOR LEGEND AND GENERAL NOTES,SEE SHEET E1.0;FOR LOCATION "^ "" PLAN,SEE SHEET E6.0). 71 10G ---------------------------I- �___ __ - ------------- P1. GENERAL NOTE:CIRCUIT NUMBERS BEGINNING WITH"N"REFER TO NORMAL BRANCH,"E"REFER TO CRITICAL BRANCH,AND"L"REFER TO c LIFE SAFETY BRANCH.DEVICES SHALL BE CIRCUITED ACCORDING TO Q Q M ,I 6 7-77 THE FOLLOWING SCHEDULE: Q — �p00 0 EC154 ND=4NLD(N) EC=4CLC(N) LA=4LLA(N) 0 J iz m NE=4NLE(N) J x a 0 w Q m ocD 4 P2. GENERAL NOTE: COORDINATE DEVICE LOCATIONS WITH Z LL ND26 ARCHITECTURAL ELEVATIONS. J z D0 LI — dmcy P3. GENERAL NOTE:WHERE CIRCUITING LINE WORK AND JUNCTION J BOXES ARE NOT SHOWN,PROVIDE SIMILAR COMPARABLE SPACES. O cl CIRCUIT TO PANELBOARD AS INDICATED,TYPICAL. P4. REFERENCE NOTE:WALL MOUNTED HAND SANITIZERS ARE TO BE O LOBBY MOUNTED A MINIMUM OF 1'0"CLEAR OF ALL ELECTRICAL SWITCHES 00 AND RECEPTACLES. N4010 v� 4Li P5. CONNECT TO EXISTING SECURITY ACCESS CONTROL I� BRANCH CIRCUIT.FIELD VERIFY CIRCUIT NUMBER. L.f. ui ND26 `I------- z r.® 8 I - LU 101 - - - - - - - - - - - � � _ = = —� �- os WU Z U LL Q I ILL U i I I I Op Lo2 � y W m N �POWER PLAN ^Q J �L U)< = m 00 - �UN�' wQ z� EQUIPMENT SCHEDULE 4 ;LLSt Luke's OMOUNT IN KNEE SPACE (GROMMETS BY OTHERS) l r # 17-531 ® MOUNT 4"ABOVE BACKSPLASH,OR 4" PROJECT DATE ABOVE COUNTERTOP IF NO BACKSPLASH 693462.V3.05 06/14/2017 154 POWER SUPPLY,SECURITY ACCESS DRAWN CHECKED CONTROL CLc JH O IN REVISED EQUIPMENT SCHEDULE NOTES: S1. GENERAL NOTE: FOR ADDITIONAL DEVICE/EQUIPMENT MOUNTING INFORMATION,SEE ARCHITECTURAL DRAWINGS. w S2. GENERAL NOTE:EQUIPMENT SCHEDULE SHOWN IS GENERAL; z SHEETTITLE NOT ALL EQUIPMENT DESIGNATIONS NECESSARILY USED POWER PLAN W_ W SHEET w E9 .0 Q pNP� cl Oy a z h o '- o 1 COMMUNICATIONS PLAN NOTES: a (FOR LEGEND AND GENERAL NOTES,SEE SHEET E1.0;FOR LOCATION PLAN,SEE SHEET E6.0;FOR EQUIPMENT SCHEDULE,SEE SHEET 10G - - - - - - - - - - - - -;- - - - - -II E9.0). Cl. GENERAL NOTE:UTILIZE THE CURRENT ISSUE OF THE SLHS 0 Fix L-I— INFORMATION TECHNOLOGIES COMMUNICATIONS DEPARTMENT c�'> VOICE AND DATA CABLING SPECIFICATIONS FOR APPLICATION TO Q 00 000 THIS PROJECT. J CD= ®D D J x ML9 C2. GENERAL NOTE:ALL COMMUNICATIONS SYSTEM CABLES FOR Lu Q 0,10 s q OUTLETS SHALL BE ROUTED FROM THE OUTLET TO THE NEAREST Z I I ,m—N�? IDF,IN DATA ROOM N4437,UNLESS OTHERWISE NOTED.PROVIDE _J Oco c T CAT.6 NON-PLENUM RATED CABLE.DO NOT ROUTE THROUGH J Z o0 PLENUM AIR SPACES. _J 0_mw _ ® NOTE C3 0 �'I C3. COORDINATE WITH APEX INTEGRATED SECURITY SOLUTIONS(MIKE FORD,(378-9650)REGARDING SECURITY SYSTEM DEVICES;DEVICE L+ _�� HARDWARE AND INSTALLATION/CONNECTION BY APEX SECURITY. CD LOBBYR 00 PROVIDE WIRING, O XES AND CONNECT ONS/RECEPTACLES FORT E SECURITY SYSTEM,AS N4010 ( 4 2 SEE SHOWN OR REQUIRED.VERIFY LOCATIONS,TYPICAL. W 10J ------------ W WU I LL Q LL 0 Op S22 1 N ` O COMMUNICATIONS PLAN Q w :2 s 1/4„=1'-01, JL CAT 6 L.�J �' U)Q =�o�� ------- f------------------------------ --- ----- sc a� 22 AWG, O> ; 4CONDUCTOR CENTRAL ------- f----------------------------------------------------------- -- - ------ r—rn HEADEND ------------------ - ------------ V ------------------------------------�i �----------------- DOOR - ------- i I u� POWER --------------------------- -- W 5 N. I z L F -------� f[----------------- SUPPLY ------------------------ Z JUNCTION BOX --- -- -------- I I -------� f----------------- -- -- - i i i 22 AWG, 6 CONDUCTOR A L St Luke's 120V 120V 154 ® REX ; 18 AWG, # 17-531 I � I 4CONDUCTOR i 22 AWG, O. M R,S j , ; PROJECT DATE 4 CONDUCTOR 693462.V3.05 06114/2017 I � I 18 AWG, DRAWN CHECKED 4 CONDUCTOR CLc JH I i I (2)22 AWG,4 CONDUCTOR J II N REVISED (1)18 AWG,4 CONDUCTOR C SS - C S S K [—P '—'A THRU ELECTRIFIED HINGE D D HINGE SIDE REX D LATCH SIDE w SECURITY SYSTEM BLOCK DIAGRAM NOTES: Z SHEET TITLE S1. GENERAL NOTE:MANUFACTURER'S STANDARD CONDUCTOR TYPES SHALL BE USED FOR D WIRING,EXCEPT#18 AWG IS MINIMUM SIZE. (COMMUNICATIONS WIRING MAY BE#22 AWG). Comm CONDUCTOR TYPES SHOWN ARE BASED ON FIRST-NAMED MANUFACTURER OF SPECIFICATIONS. VERIFY ALL WIRING TYPES WITH SECURITY SYSTEM SUBCONTRACTOR PRIOR TO PURCHASE. STD DOOR W/ACCESS CONTROL PLAN S2. GENERAL NOTE: ROUTE ALL CONDUCTORS FOR THIS SYSTEM IN CONDUIT,3/4"C MINIMUM,FROM (ENTRY SIDE) w EACH DEVICE TO THE NEAREST CABLE TRAY. SEE SHEET E1.0 FOR GENERAL REQUIREMENTS. _ S3. GENERAL NOTE:THIS IS A TYPICAL WIRING DETAIL;NOT ALL DEVICES SHOWN MAY BE REQUIRED FOR THIS PROJECT. ALSO,VERIFY ALL WIRING REQUIREMENTS TO THE DEVICES. SHEET S4. GENERAL NOTE: SEE LOCATION PLAN,SHEET E6.0,FOR LOCATION OF EQUIPMENT ON EACH FLOOR. } SECURITY SYSTEM BLOCK / WIRING DIAGRAM LA E 10 .0 1 NTS 0