Loading...
HomeMy WebLinkAbout16-1693 801 Pole Line Rd W Repipe-Repair Plans - - KEY NOTES 1 I A I. PLUG BOTTOM INLETS INTO TANKo . FRORFs j (73' OF 4) - - {.___ _,.y 2. VACUA XISTING TANK FILLWITH SAND ABANDON IN - 1 �IjiCp�' l ACCORDANCE WITH LOCAL REQUIREMENTS.` 4 --- ------_. ...._ - --. -_ -_.._. - --rr -- ------ --- -- ___. ...-- - ___ --_. --. __ ___ --- ------- -- ---- 3850 ___- _ ----- 3. PLUG VENT PIPING OUTLET IF REQUIRED BY LOCAL AUTHORITIES. 't '�17`F ! ? — 111 -_ °' _ -.__ __ _ _ '( ._ _ :__ __ - — _ 4. INTERGEPi EXISTING 4'WASTE LINE< ROUTE TO LAST TANK D-iTt- { 5. SLOPE At MINIMUM GRADE. N 6. INLET TO BE SAME I.E.AS OUTLET. __________________________________________________________________I'' INTERCEPTOR 40�Z`G'J L.._________--I____.______________________________ ---------------------- ^-----GALLONS EACH JJJ r_________________ ______ COOTG 4„ f " Ca oTr ---_--- _-- ---'__, 3' 4" ABANDON PIPING 3 ABANDON PIPING 4" o 4 COTG i 4" 4" COTG a o COTG COTG COTG o iGOTG o INi o 0 o GOTG a ,ten „ 0 1 N COTG I 4 6 COTG 3 2 4 o m`=of m o w I 2 12 I Nm°c� I > 4" ABANDON PIPING 4" ABANDON PIPING I I' w a o COTG o COTG o a OU COTG 4„ 5 COTG'1 KEY PLAN g w �m PARTIAL WASTE & VENT FOUNDATION FLOOR PLAN1. 2' V 0' 4' 8' 1/4" 1'_0" rr^^ vJ Z V 0 EXISTING VENT M.N.-� COTG-� M.H. EXISTING VENT M.H. COTG M.H. M.H. C OTG M.H. GROUT WATERTIGHT wN ----- NEW INLET 4n w Of J (7 PLUG VENT PLUG VENT ABANDON PIPING �\f Z F— 2 2 EXISTING OUTLET U C z Q < 0 LL PLUG INLET PLUG INLET 4 4 z w Q REVIEWED 9/3/16 JV Y U 2 4000 GALLON GREASE INTERCEPTOR DETAIL J ~ w ry � z � w Q UJ w 0 A 0 e a u, L m K rt Z uW v U Y w w U G Building Plans have been reviewed and approved SHE All Construction Subject to c Field Inspection Page#: 1 of 4 Date: 9/8/16 q J TRAPS AND INTERCEPTORS Table 10-3—1015.1 Table 10-3 Gravity Grease Interceptor Sizing DFUs(1,3) Interceptor Volume(2) 8 500 gallons 21 750 gallons 35 1,000 gallons 90 1,250 gallons 172 1,500 gallons 216 2,000 gallons 307 2,500 gallons 342 3,000 gallons 428 4,000 gallons 576 5,000 gallons 720 7,500 gallons 2112 10,000 gallons 2640 15,000 gallons Notes (1) The maximum allowable DFUs plumbed to the kitchen drain lines that will be connected to the grease interceptor. (2) This size is based on:DFUs, the pipe size from this code;Table 7-5;Useful Tables for flow in half-full pipes (ref:Mohinder Nayyar Piping Handbook,3rd Edition, 1992). Based on 30-minute retention time(ref.: George Tchobanoglous and Metcalf& Eddy.Wastewater Engineering Treatment,Disposal and Reuse,3rd Ed.1991&Ronald Crites and George Tchobanoglous.Small and Decentralized Wastewater Management Systems,1998).Rounded up to nominal interceptor volume. (3) When the flow rate of directly connected fixture(s)or appliance(s)have no assigned DFU values,the additional grease inter- ceptor volume shall be based on the known flow rate(gpm)multiplied by 30 minutes. 1014.3.2.2 Toilets,urinals,and other similar 1014.3.5 Construction Requirements. fixtures shall not drain through the interceptor. 1014.3.5.1 Purpose. Gravity grease inter- 1014.3.2.3 All waste shall enter the intercep- ceptors shall be designed to remove grease for through the inlet pipe only. from effluent and shall be sized in accor- 1014.3.3 Design. dance with this section. Gravity grease inter- 1014.3.3.1 Gravity Interceptors shall be con- ceptors shall also be designed to retain structed in accordance with the applicable grease until accumulations can be removed standard in Table 14-1 or the design by pumping the interceptor. It is recom- approved by the Authority Having mended that a sample box be located at the Jurisdiction. outlet end of all gravity grease interceptors so that the Authority Having Jurisdiction can 1014.3.4 Location. periodically sample effluent quality. 1014.3.4.1 Each grease interceptor shall be 1014.3.6 Sizing Criteria. so installed and connected that it shall be at all times easily accessible for inspection, 1014.3.6.1 Sizing. The volume of the inter- cleaning, and removal of the intercepted ceptor shall be determined by using Table grease.A gravity grease interceptor comply- 10-3. If drainage fixture units (DFUs) are not known, the interceptor shall be sized based ing with IAPMO Z1001, shall not be installed in any part of a building where food is han- on the maximum DFUs allowed for the pipe dlecl. Location of the grease interceptor shall size connected to the inlet of the interceptor. meet the approval of the Authority Having Refer to Table 7-5, Drainage Piping, Jurisdiction. Horizontal. 1014.3.4.2 Interceptors shall be placed as 1014.3.7 Abandoned Gravity Grease close as practical to the fixtures they serve. Interceptors. Abandoned grease interceptors 1014.3.4.3 Each business establishment for shall be pumped and filled as required for aban- which a gravity grease interceptor is doned sewers and sewage disposal facilities in required shall have an interceptor which Section 722.0. shall serve only that establishment unless otherwise approved by the Authority 1015.0 FOG (Fats, Oils, and Greases) Disposal Having Jurisdiction. System. 1014.3.4.4 Each gravity grease interceptor 1015.1 Purpose. The purpose of this section is to shall be located so as to be readily accessible provide the necessary criteria for the sizing, applica- to the equipment required for maintenance. tion, and installation of FOG disposal systems desig- 151 St.Lukes Magic Valley Kitchen Grease Laden Fixtures 9/6/2016 Fixture Callout Quan. Drain FU Total FU Comment Floor drain P-15 7 2 14 Emergency floor drains-include to be conservative Floor sink P-16 6 2 12 Up to 15 gpm(per table 7-4) Floor sink(4") P-17 1 4 4 Up to 30 gpm(per table 7-4) Trench drain P-42 1 4 4 Up to 30 gpm(per table 7-4) Trench drain _ P-55 1 4 4 Up to 30 gpm(per table 7-4) Sink(single compartment) K-13 1 2 2 Sink(single compartment) K-24 2 2 4 Sink(single compartment) K-85 1 2 2 Triple compartment sink K-90 1 6 6 Sink(single compartment) K-131 1 2 2 Total drain FU 54 Connected grease laden drain fixture units(2009 Idaho State Plumbing Code) Per code chapter 10 section 1014.3.6.1 and table 10-3 for gravity interceptor sizing 1,000 gallon interceptor-35 FU max connected capacity 1,250 gallon interceptor-90 FU max connected capacity Use 1,250 gallon interceptor tank as connected drain fixture load is 54FU ANAL SF 4 OF q� a� St.Lukes Meridian Kitchen Grease Loading 2" U�D V.Uf- A. 4k • "W" 3 4" 2Y, -------------- eo� CC Fm U I V.uo R11 co e. :1 vc c 08. )z 3..V.ur 2 4. N, E-3. Qw, 4!� 4, t�'%c r UP 3/�@eCFp/y pt q ,`� / C C6 21,V.Up- J 4� 12 41 J OoT 2"\-V- AQ q COTF -------- 7Z, -- A, 2 n, V.UP 4 4 D F-S Y7 ❑ 4 7r. 211 -------------------------- 411 Coco 411- 4" 11 Y9 / 0 41 2 4" 21,V.UP 0 211 2 2- / n 4 4" 2OG r