Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
15-1557 801 Pole Line Rd W plans
ARCHITECT IC___ HUMMEL ARCHITECTS PLLC ,uw� ei015 RECEIVED 2785 N.BOGUS BASIN ROAD BOISE,ID 83702 PHONE:2D8.343.7523 CONTACT:GARY SORENSEN TUN 16 2015 aua FAX:208.343.0940 �4AIL:gwrensen@hummelarch.wm iMN FALLS FIRE DEFT. CITY BUIGIfv't1 UcFT. STRUCTURAL ENGINEER J L CH2M HILL 322 EAST FRONT STREET SURE no BOISE,ID83702 ►'ROV T'wln Fales E®PHONE:208.345.5310 CONTACT:WAYNE KOHLER FAX:208.315. EMAIL:wayne.kohler@ch2m.com SLMV 2ND �d�DeAt.MECHH ANICAL ENGINEER CATH LAB ENGINEERING INC. .�_i�_�y 2222 S.BROADWAY AVE. / BOISE,ID 83706 - - - - -. PHONE:208,343.3683 CONTACT:MICK GREFENSON FAX:208,343.9625 EMAIL:michaelg@engineennginc.mm ELECTRICAL ENGINEER L� �9 801 POLE LINE ROAD WEST CH2MHILL S"' t 322 EAST FRONT STREET SUITE 200 BOISE,ID 83702 PHONE:208.345,5310 CONTACT:CHRISTOPHER WILLIAMS FAX 2D8.345.5310 EMAIL:dhih,Wpher.WAliama@ch2m.cam 116 ABBREVIATIONS PROJECT DESCRIPTION MATERIAL & SYMBOLS DRAWING INDEX # NUMBER POUND GA GAUGE SC SEALED CONCRETE O REFERENCE TAG GENERAL e DIAMETERR SL PROJECT#: 15-310 GALV GALVAN SCHEDULE G0 ZED SCHED .00 COVER SHEET FOR REFERENCE ONLY MEDICAL EQUIPMENT ANGLE GB GYPSUM BOARD SCW SOLID CORE WOOD AT GYP.BD. GYPSUM BOARD SGWB SUSPENDED GYPSUM G0.02 DRAWING INFORMATION -DUAL PLANE LAB #.# GRIDAEVEL HEAD C1 COVER O & AND WALLBOARD GN GENERAL NOTES � CL CENTERLINE HAS HEADANCHORSTUD SHT SHEET DEMOLITION Al EQUIPMENT LAYOUT Q CORE D201 DEMO FLOOR PLAN A2 EQUIPMENT ELEVATIONS J HIM HOLLOWMETAL OD SHTG SHEATHING PROJECT TENANT: ® WALL TYPE TAG D901 DEMO CEILING PLAN A3 EQUIPMENT ELEVATIONS AS ANCHOR BOLT HIM HOLLOW METAL SIM SIMILAR ST.LUKE'S MAGC VALLEY A4 EQUIPMENT SCATTER RADIATION DIAGRAMS ACP I ACOUSTICAL CEILING PANEL HORIZ HORIZONTAL SPECS SPECIFICATIONS ST.POLE LINE ROAD WEST 51 FLOOR SUPPORT LAYOUT ADJ ADJUSTABLE ACT ACOUSTICAL CEILING TILE HT HEIGHT 54 SQUARE O WINDOWTAG ARCHITECTURAL TWIN FALLS,ID 83301 S2 CEILING SUPPORT LAYOUT HW HARDWOOD SS STAINLESS STEEL A2.01 FIRST FLOOR COMPOSITE PLAN AFF ABOVE FINISH FLOOR STD STANDARD CONTACT:MARK ROBE A2.11a FLOOR PLAN 53 FLOOR STRUCTURAL DETAILS ALUM ALUMINUM ICMU INTEGRAL COLORED STL STEEL PHONE:208.890.2592 O DOORTAG S4 CEILING STRUCTURAL DETAILS ANOD ANODIZED CONCRETE MASONRY UNITS STOR STORAGE A2.1lb LEAD SHIELDING PLAN E1 ELECTRICAL LAYOUT m APPROX APPROXIMATE ID INSIDE DIAMETER STRUCT STRUCTURAL A7.01 DOOR SCHEDULE,TYPES AND DETAILS E21 CEILINGELECTRICAL SCHEMATICS ASSOC ASSOCIATED INSUL INSULATION SUSP SUSPENDED ROOM NAME A8.01 ROOM FINISH SCHEDULE AND PLAN E2.2 FLOOR ELECTRICAL SCHEMATICS -a AWP ACOUSTICAL WALL PANEL TNT INTERIOR SV SHEETVINYL E3 ELECTRICAL DETAILS/POWER QUALITY REQUIREMENTS $ AWS ACOUSTICAL WALL SYSTEM INV INVERT PROJECT OWNER/CONSTRUCTION MANAGER: ® ROOM TAG A8.52 INTERIOR ELEVATIONS E4 CABLE LIENGTH DIAGRAM(FOR INTERNAL USE ONLY) A8.52 INTERIOR DETAILS T T&G TEMPORA ND GROOVE ST.LUKE'S HEALTH SYSTEM 150 SF A9.01 REFLECTED CEILING PLAN 2 U) J m BD BOARD JAN JANITOR TEMP TEMPORARY 190 EAST BANNOCK ST, FOR REFERENCE ONLY W LU m N BFC BROOM FINISH CONCRETE JET JOIST TO TOP OF BOISE,ID 83712 � CASEWORK TAG STRUCTURAL MEDICAL EQUIPMENT-ANGIO LAB �o BLDG BUILDING JT JOINT TOM TOP OF MASONRY PHONE:208.381.2023 FAX:208.381.4613 36' 16' 50.1 GENERAL STRUCTURAL NOTES BABBREVIATIONS C1 COVER SHEET BLKG BLOCKING TS TUBE STEEL CONTACT:STAN BROWN 36' S1.1 EQUIPMENT SUPPORT PLANS GN GENERALNOTEE ! l Q m L o BM BEAM LAB LABORATORY TYP TYPICAL Extra She# S1.2 CEILING MOUNTED EQUIPMENT PLAN At EOLIIPMEIN LAYOUT `J BO BOTTOMOU LAM LAMINATE r o BOG BOTTOM LAV LAVATORY JOIN UNLESS OTHERWISE NOTED Q Z BRG BEARING S3.1 EQUIPMENTSUPPORTDETAILS A2 EQUIPMENT ELEVATIONS BSMT BASEMENT MAT METERIAL VAR VARIES SHEET#SECTION# qp1 WALL SECTION 53.2 EQUIPMENT SUPPORT DETAILS A3 EQUIPMENT ELEVATIONS 7 Lu Q 8 o M EQUIPMENT SCATTER RADIATION DIAGRAMS L W �T'' 3 m MECHANICAL 51 FLOOR SUPPORT LAYOUT Z 2 N m N N BTVN BETWEEN MAX MAXIMUM VCT VINYL COMPOSITION TILE M0,0 MECHANICAL COVER SHEET S2 CEILING SUPPORT LAYOUT N J MECH MECHANICAL VERT VERTICAL M1.1 HVAC DEMOLITION PLANS S3 FLOOR STRUCTURAL DETAILS CAB CABINET MET METAL VEST VESTIBULE PROJECT: EEION�LETTER 1 BUILDING SECTION M1.2 HVAC REMODEL PLANS 54 CEILING STRUCTURAL DETAILS WCPT CARPET M2.1 HYDRONG RDELP&REMODEL PLANS E1 ELECTRICAL LAYOUTC0L0*1 C.I.P. CAST-IN-PLACE MFR MANUFACNRER W/ WITH 1,985 SF TENANT IMPROVEMENT/REMODEL ON LEVEL 1 IN AN EXISTING 5 STORY HOSPITAL, M21 PLUMBING REMODEL DEMOLITION&R E2 ELECTRICAL SCHEMATICS C W CJ CONTROLJOINT MIN MINIMUM WC WATER CLOSET SCOPE OF WORK INCLUDES THE ADDITION OF A CATH LAB WITH ANCILLARY FUNCTIONS TO SIM P2.1 MEDICAL GAS DEMOLITION&REMODEL PLANS E3 ELECTRICAL DETAILS/POWER QUALITY REQUIREMENTS AN EXISTING SHELLED SPACE THAT WAS PLANNED FOR A FUTURE CATH LAB AS WELL AS A VIEW#OR LETTER 1 DETAIL OR ENLARGED PLAN FPIA FIRE PROTECTION PLAN E4 CABLE LIENGTH DIAGRAM FOR INTERNAL USE ONLY) J CIE CENTERLINE MISC MISCELLANEOUS WD WOOD CLG CEILING MIL MEASURING LINE WF WALL FABRIC REMODEL TO AN EXISTING CATH LAB.DEMOLITION WORK TO OCCUR TO ACCOMMODATE SHEET# Atl.N# CALLOUT ( h CMU CONCRETE MASONRY UNITS MO MASONRY OPENING WH WATER HEATER NEW CONSTRUCTION,NEW CONSTRUCTION TO INCLUDE WALLS,DOORS,MILLWORK, ELECTRICAL CO GO CLEAN OUT NIM MOUNTED WM WALK-OFF MAT FINISHES,HVAC,PLUMBING,ELECTRICAL AND INSTALLATION OF SPECIALTY MEDICAL ^1 E7.0 ELECTRICAL LEGEN&GENERAL NOTES COL COLUMN MTG MOUNTING W/O WITH OUT EQUIPMENT. INTERIOR ELEVATION ED1.2 POWER PLAN DEMO CONS CONCRETE Wp WATERPROOF ED1A LIGHTING PLAN DEMO �����Q&C CONST CONSTRUCT NA NOTASE(EX OS WRGB WATER RESISTANT ED1.4 COMM PLAN DEMO es CONT CONTINUOUS NB NOBASE(EXPOSED GYPSUM BOARD B.O.DECK ED1.5 FIRE ALARM PLAN DEMO CSK COUNTERSINK WALL OR FOUNDATION) WT WEIGHT 0, CK LEVEL NAME/ELEVATION MARKER E2.0 POWER PLAN #15-310 CMT CERAMIC MOSAIC TILE INC NEW CONCRETE WWF WELDED WIRE FABRIC E2.1.1 ANGIO LAB CEILING CONDUIT PLAN CDT CERAMIC QUARRY TILE NIC NOT IN CONTRACT E2.1.2 ANGIO LAB FLOOR CONDUIT PLAN CWB CERAMIC WALL BASE NM NEW MASONRY E2.2.1 DU ALP LANE CEILING CONDUIT PLAN NO NUMBER E2.2.2 DUAL PLANE FLOOR CONDUIT PLAN PROJECT LDATE DBL E2.3 BASEMENT&1ST FLOOR LOCATION PLAN 15008 92015 DOUBLE NOM NOMINAL E2.3.1 1ST FLOOR LOCATION PLAN DEPT DEPARTMENT NTS NOT TO SCALEDT DETAILNORTH ARROW E3.0 LIGHTING PLAN DRAWN ECKED DF DRINKING FOUNTAIN OC ON CENTER E4.0 COMM PLAN CB DIA DIAMETER OD OUTSIDE DIAMETER E5.0 FIRE ALARM PLAN DIM DIMENSION OFF OFFICE E6.0 NORMAL ONE-LINE RISER DIAGRAM DN DOWN OFCI OWNER FURNISHED/ E6.1 EMERGENCY ONE-LINE RISER DIAGRAM REVISED: DS DOWNSPOUT CONTRACTOR INSTALLED E7.0 ELECTRICAL DETAILS # OFOI OWNER FURNISHED/ E8.0 ELECTR EA EACH OWNER INSTALLED LE CAL EQUIPMENT SCHEDULE # Description Date E E8.1 E CTRICAL PANEL SCHEDULE EXPANSION BASE TRIM OPNG OPENING 1 View Name EJ EXPANSION JOINT OTA OPEN TO ABOVE #- ELEC ELECTRICAL OTS OPEN TO STRUCTURE VIEW VIEW TITLE ELEV ELEVATION OVF OVERFLOW SHEET# A101 1I8'=1'-0" EP EPDXY PAINT ED EQUAL PC PAINT COLOR EQUIP EQUIPMENT P.I.V. POST INDICATOR VALVE ESTR EXPOSED STRUCTURE PLAST PLASTIC (NEW OR EXISTING) PLYWD PLYWOOD E EIFS EXTERIOR INSLIM LAT ION PR PAIR aI EXISTING VICINITY MAP , KEY PLAN GENERAL NOTES EXIST R THERMAL RESISTANCE ? EXP EXPANSION RCP REFLECTED CEILING PLAN EXT EXTERIOR RD ROOF DRAIN ` RDL RAIN DRAIN LEADER O FD FLOOR DRAIN RE: REFERENCE ,p.,w°•� °°�"„° ,.,„.,°.w ,„v,� g F.D.C. FIRE DEPARTMENT CONNECTION REFRIG REFRIGERATOR _ �,.. w 1. DO NOT SCALE DRAWINGS. '- FB FIRE BLANKET REINF REINFORCING vre 2. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO WORK. m FE FIRE EXTINGUISHER RED REQUIRED 3. SCREENED LINES REPRESENT EXISTING WALLS,DOORS,WINDOWS, SHEET TITLE FF FACTORY FINISH RF EPDXY FLOOR SYSTEM PROJECT ""' ETC. F.H. FIRE HYDRANT RM ROOM - a j� 4. WHERE NEW H CONSTRUCTION ABUTS AND LANEXISTING,SO THERE SHALL MEET COVER s FIN FINISH RO ROUGH RSTAI T LOC TION. tiw gq ` SEAMS IN THE FINISH PLANE SO THERE IENONOTICABLE FL FLOOR LINE RN RUBBER STAIR TREADS l//'1 'w. SEAMS T I BREAKS IN THE FINISH PLANE. SHEET U FLR FLOOR RN REDWOOD p x ; EXISTING TENANN/ 5. PROTECTIN PLACE AMAEXISTING ETCONSTRUCTION NOT NOTED FOR > FND FOUNDATION RWB RUBBER WALLBASE - m�„„,.,, w`"°°'°m DEMOLITION.ANY DAMAGE TO EXISTING CONSTRUCTION SHALL BE Wew aok PACE TO REMAI REPAIRED TO ORIGINAL STATE. FOC FACE OF CHANNEL RWC RAIN WATER CONDUCTOR °"`"` `"`�" 6. WHERE EXISTING WALLS ARE REMOVED,PATCH THE FLOOR AREA WITH „wx FOF FACE OF FINISH �, „,,,,,°,„ PATCHING COMPOUNDAS RECOMMENDED BY FLOORING FOS FACE OF STUDS ^, r ro - FTG FFT EOOTING ,- 7. SALVAGE ITEMS AS NOTED ARE TO BE STOCKPILED IN COMMON FV FIELD VERIFY "'"°m .... e ,, LOCATION AS DIRECTED BY THE OWNER 8. WHERE EXISTING CONSTRUCTION TO REMAIN ADJOINS DEMOLISHED ITEMS AND WALLS,PATCH AND REPAIR THE EXISTING CONSTRUCTION SHEET Po Wp m SO THERE IS NO NOTICEABLESEAMS OR BREAKS IN THE FINISH PLANE. Building Plans have been reviewed and approved AREA OF WORK a w # ..,... ..instruction Subject Field Inspection G0. N FIRST FLOOR U A Date IS U �O WALL TYPE DESCRIPTION WALL TYPES GENERAL NOTES FIRE RATING WALL HEIGHT REMARKS S28 210 STEEL STUDS WITH SWGYPSUM WALLBOARD ON ONE SIDE NON-RATED TO DECK ABOVE 1. WALL TYPES DESCRIBED ON THIS SHEET DO NOT AMOUNT FOR REOUIRED WALL MOUNTED FIXTURES, S31SL 3 W STEEL STUDS WITH 5V GYPSUM WALLBOARD ON BOTH SIDES WITH SOUND ATTENUATION INSULATION "OUR TODECKABOVE EQUIPMENT CAASEWORK AND/OR CKING AND/OR SUP SYSTEMS FURNITURE.COORDINATE BLANKETS IN STUD CAVITIES AND LEAD SHIELDING PER SHIEDDING PLAN WITH ENLARGED FLOOR PLANS,INTERIOR ELEVATIONS AND EQUIPMENT S36L 3 5/S'STEEL STUDS WITH SAS'GYPSUM WALLBOARD ON BOTH SIDES WITH LEAD SHIELDING PER SHIELDING PLAN, NON-RATED TO DECK ABOVE PLANS PRIOR TO THE COVERING OF STUD FRAMING.REFER TO S36S 3 5I8'STEEL STUDS WITH 5/S'GYPSUM WALLBOARD ON BOTH SIDES WITH SOUND ATTENUTATION INSULATION NONRATED TO DECK ABOVE MANUFACTURER'S RECOMMENDATIONS AND USE DETAIL S'A8.52 WHERE BLANKETS IN STUD 9 VRTES APPLICABLE S38SL 3518'STEEL STUDS WITX SS'GYPSUM WALLBOARD ON BOTH SIDES WITH SOUND ATTENUTATION INSULATION NONRATED TO DECK ABOVE 2• PROVIDE SEISMIC BRACING PER DETAIL 6/A8.52 AT ALL WALL TYPES THAT BLANKETS IN STUD CAVITIES AND LEAD SHIELDING PER SHIELDING PLAN. DO NOT EXTEND TO DECK S37S 3 5/8'STEEL STUDS WITH&S'GYPSUM WALLBOARD ON BOTH SIDES WITH SOUND ATTENUATION INSULATION NON-RATED TO8'ABOVE CEILING 3. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE SEALED AS BLANKETS IN STUD CAVITIES PER MANUFACTURERS RECOMMENDATION AND IN ACCORDANCE W/ ASSOCIATED UL LISTING S86SL 6-STEEL STUD WITH(1)LAYER OF 5V GYPSUM WALLBOARD ON EACH SIDE WITH SOUND ATTENUATION INSULATION NONRATED TO DECK ABOVE 4. HORIZONTAL BRACING 24Y AF.F.AT FIRST OCCURRENCE AND EVERY 4'-0' BLANKETS IN SND CAVITIES AND LEAD SHIELDING PRE SHIELDING PLAN THEREAFTER AT ALL WAILS W/GYPSUM BOARD ON ONLY ONE SIDE.S78SL HALF OF A DOUBLE WALL TYPE.35/8'STEEL STUDS WITH&8'GYPSUM WALLBOARD ON ONE SIDE WITH SOUND NON-RATED TO DECK ABOVE 5. AT ALL WALLS WITH SOUND ATTENUATION,SEAL TOP OF WALL AT 9 yb ATTENUTATION INSULATION BLANKETS IN STUD CAVITIES AND LEAD SHIEEDING PER SHIELDING PLANS. STRUCTURE AND BOTTOM OF WAL;0MTH SOUND SEALANT 6. ALL WALLSTHAT�XTENDTO'$Tf IJCTI�RE PROVIDE DEFLECTION TRACK S�- TRACK 7. SEE SHEETS AZ'IIb FOR SHIELDING INFORMATION. •� VIM ® I CODE ANALYSIS :zla I I APPLICABLE CODES: 20121BC;20121FC; C 666DDD O 2012IMC;2014 NEC;20121ECC; 20091CCIANSI A117.18009;2DD8 FGI a y O O ESo o SWBPANCY GROUP (2� CONSTRUCTION TYPE: (t�SPRINKLERED ~FINISH FLOOR H s e `� EMERGENCY LIGHTING: YES � H FIRE ALARM SYSTEM: YES(PER IBC 907.2.6) MIRROR GRAB BARS SOAP ELECTRIC PAPER TOWEL AUTOMATIC SPRINKLER TOILET PAPER SANITARY CUSTODIAN SANITARY FIRE SYSTEM: YES(PER IBC 9D3.3.1.1) DISPENSER HAND DRYER DISPENSER DISPENSER NAPKIN UTILITY SHELF NAPKIN EXTINGUISHER(COORDINATE WITH SMOKE BARRIER WALLS: I-HR. ELECTRICAL) DISPOSAL DISPENSER CABINET OPENING PROTECTIVES: DDORS: 113 HR. TYPICAL ACCESSORIES MOUNTING HEIGHTS DUCTS:SIDELIGHTS: S314 HR. MOKE GU OZ DAMPERS�-O OTHER: PENETRATION FIRESTOPPING NOTE:SEE EXCEPTIONS IN IBC. SMOKE PARTITIONS: NON-RATED UNOBSTRUCTED FIRE OPENING PROTECTIVE& SMOKE S DRAFT CONTROL ASSEMBLIES O ALARM PULL BOX UNOBSTRUCTED SWITCH NQ.SEE EXCEPTIONS IN 18C. 1 0 UNOBSTRUCTED MAXIMUM TRAVEL DISTANCE: 200'-0" J MAXIMUN COMMON PATH OF THERMOSTAT EGRESS TRAVEL: 75'.0"(NON-SLEEPING ROOMS): OCCUPANT LOAD: 20 OCCUPANTS(1,985 SF./100 SF I �v•� OCCUPANT) co REQUIRED NUMBER OF EXITS: 1(ONE) M RECEPTACLE �j REQUIRED EGRESS WIDTH W OUTLET 3 DOORS: 41.5 INCHES CLR.(I-2 OCCUPANCY-FOR MOVEMENT OF BEDS) Q ul) J�, Lu Lu Lu RECEPTACLES AND SWITCH MOUNTING HEIGHTS Q g o U o p9mo 2 MISC. MOUNTING HEIGHTS o _.v G0.02 3/8'_1'-0" — z w .2 m m Z 7,0.. m Lu UALL 1 r Luke's ------------- EDRAWN CT DATE 5.29-2015 CHECKED JS REVISED: A # Desorption Date SHEET TITLE DRAWING INFORMATION SHEET LG0.02 a tZv sm \WE ENE \p KOM sm SHEET TITLE DEMO FLOOR ON ammommials, 10,11 PLAN e � It MIEN N v\. \� , �y� ........�,....�...........� mmii vv v ,♦ A�V A \V �. A .������. \ ,\.�`�.v \\\\ �```` \\\\\\� \ ` \�a \ \_. \\� \ \\ \ �V A \ \V� \ \vvvvvovvvvo�-''� �\ \\\\!��'� A\\\'i�l�� �\ \' \\\O \ \_-- \\ \ \ \\�;\�` \� ��, \\\�\\\\OHO � • Aq \\i�'i \ Raw^1� \CVO v1 \ \\I; �'1 � A�1A \\�OR A��. Aq� !��V� \-gl A� \\\� gV� \ \\Ai \\ \t 9. A\`i �1 AI A\ \�A\V / 1 A\� \\ � m I \l �,'�,�I vv�\• v laffillsoN INN Sol Ks i �\.\\. _ __ - �\ \ \ \�.\ , \\�! M \ \\ \ s, "Im \ \ ON !'\mwm�mumo,' INIMENNINNINII, \ \ \ • - . 0 • - / WAR� j9. . . . .. . . .. .. .. . .. .. . . . . . . .. . . . . . .. . .. .. .. .. . . .. . . . . .. GENERAL NOTES 1. UNLESS NOTED OTHERWISE,ALL DIMENSIONSARE TO THE FACE OF STUDS FOR GWB WALLS/PARTITIONS. 2. FOR FLOOR FINISHES RE:FINISH PLANS 3. UNLESS NOTED OTHERWISE ALL GWS WALLS SHALL HAVE A WSTUO FRAME RETURN AT ALL DOOR AND WINDOW JAMBS 4. RE:INTERIOR ELEVATIONS FOR LOCATION OF FIXTURES AND EQUIPMENT NOT NOTED ON PLANS, S. FOR WALL TYPES COORDINATE WITH FLOOR PLANS AND DRAWING AND CODE INFORMATION SHEET. 8. PROVIDE BACKING BEHIND TYPICAL SURFACE MOUNTED EQUIPMENT ANDIOR FIXTURES.RE:DETAIL 5/A8.52. 7. RE:DOOR HARDWARE SCHEDULE FOR HARDWARE GROUP INFORMATION, 8. RE:DOOR SCHEDULE SHEET FOR DOOR TYPES. 9. SCREENED LINES REPRESENT EXISTING WALLS,DOORS,WINDOWS,ETC. TO REMAIN. 10. AT ALL OUTSIDE EXPOSED COUNTERTOP CORNERS PROVIDE T RADIUS T� CORNER. y' 11. WHERE NEW WALL CONSTRUCTION ABUTS EXISTING WALL CONSTRUCTION,CONTRACTOR TO MODIFY EXISTING WALL d /✓//,� CONSTRUCTION TO MATCH CHARACTERISTICS OF NEW WALL.I.E.WHERE ' NEW WALL TYPEFRAMING TO FOR SOUND ATTENUATIONALLS SHALL BE TION EXTENDED KET AND AND WALL FRAMING TO DECK,ABUTTING WALL HALL BE EXTENDED AND .. SLANKTSADDED. 55 12. UNLESS NOTED OTHERWISE,ALL COUNTERTOPS TO BE 24'DEEP. H 13. REPAIR ALL DAMAGE TO EXISTING WALLS TO MATCH ADJACENT FINISH. 14. SFM DDITIONAL WALL TYPE H ELDING PLANS,HE TA2.11 INFORMATION SEE WALL TYPES AND LEAD 15. PROVIDE BACKING AND STRUCTURAL SUPPORT FOR ALL MAJOR EQUIPMENT,COORDINATE WITH EQUIPMENT MANUFACTURER'S SUBMITTALS 18. PROVIDE 2-3I8'DIAMETER PLASTIC GROMMET WITH FLUSH PLUG TYPE COVER BLACK,AS MANUFACTURED BY'HAFELE'OR EQUAL AT EACH WORKSTATION SURFACE OR COUNTER STATION WITH OPEN KNEE SPACE BELOW COUNTER EXISTING TENANT PACE TO RE, AI EXISTING TENAN SPACE TO REMAIN O REA OF WORK m m �— LLl W Mcl �O Lrv'��o 0 Lu m NCN N „ a j ✓ria C/) 00 1 I #15-310 PROJECT DATE 15M 5-29-2015 DRAWN CHECKED co JS REVISED: k 0 Descdp0on Date STINGTENAN ����tY"- `'� PACE TO REMAI KEYPLAN SHEET TITLE FIRST FLOOR COMPOSITE EXISTING TENAN PLAN SPACE TO REMAIN SHEET a 1 LEVEL 1- COMPOSITE FLOOR PLAN AREA OF WORK A2.01 A2.01 1132"=1'-0" o 0 . . . . .. .. .. .. .. .. . . . .. .. .. . . . . .. . . .. .. .. . . .. .. .. .. .. LEGEND REFERENCE NOTES O 1.02 INFILL OPENING WITH SIMILAR TYPE CONSTRUCTION AS ADJACENT O DOOR SYMBOL,RE:DOOR SCHEDULE,SHEETA7.01 WALL 1.08 RELOCATED LEAD LINED WINDOW AND FRAME,COORDINATE WITH WALL TYPE,RE:SHEET G0.01 DEMOLITION PLANS, 1.08 ADD LAYER OF 1132"LEAD SHIELDING OVER EXISTING RATED WALLTO 7-0"AFF.ADD 1 LAYER OF 5W GYPSUM WALL BOARD OVER LEAD o STEEL STUD WALL AND GYPSUM BOARD WALL RE:WALL SHIELDING TO 6'ABOVE CEILING.COORDINATE WITH LEAD SHIELDING 1 TYPES, PLANS,PATCH AND REPAIR DAMAGED AREAS TO ORIGINAL STATE. o STEEL STUD WALL AND GYPSUM BOARD WALL TO REMAIN. 1.09 PROVIDE BACKING IN WALL FOR CABINETS.COORDINATE WITH EQUIPMENT MANUFACTURER'S DRAWINGS. O 1.10 CORE DRILL THRU FLOOR COORDINATE WITH ELECTRICAL,STRUCTURAL pp1 WINDOW TYPE.RE:DOOR SCHEDULE,TYPES AND DETAILS AND MEDICAL EQUIPMENT MANUFACTURER DRAWINGS. I SHEET. 1.11 AREA OF EMBED,COORDINATE WITH DEMO AND STRUCTURAL DRAWINGS. 1.14 ADD LEAD SHIELDING PER SHIELDING DRAWINGS AND COVER WITH 518' TYPE GYPSUM WALL BOARD. 10.25 ANGIO WORKSTATION.COORDINATE WITH MEDICAL EQUIPMENT \ MANUFACTURER DRAWINGS. LLo ,0.27 MAIN CONTROL CONSOLE,COORDINATE WITH MEDICAL EQUIPMENT FF.1 MANUFACTURER DRAWINGS, 10.36 ANCHOR BRACKET FOR RACK CABINET.COORDINATE WITH MEDICAL EQUIPMENT MANUFACTURER DRAWINGS. 10.37 WALL MOUNTED LARGE MONITOR MANAGER AND VIDEO EQUIPMENT. PROVIDE BACKING PLATE IN WALL,COORDINATE WITH MEDICAL EQUIPMENT MANUFACTURER DRAWINGS. 10.38 J-SOX FLUSH MOUNTED IN FINISH FLOOR COORDINATE WITH ELECTRICAL AND MEDICAL EQUIPMENT MANUFACTURER DRAWINGS. 10.42 BLANKET WARMER. 4 26.03 PUSH BUTTON ACTUATOR FOR AUTOMATIC DOOR OPENER. COORDINATE WITH ELECTRICAL DRAWINGS. ,.+4 se6sL o3 GENERAL NOTES IL "p 1. UNLESS NOTED OTHERWISE,ALL DIMENSIONS ARE TO THE FACE OF Q, n STUDS FOR GWB WALLS I PARTITIONS. to R Hv 2. FOR FLOOR FINISHES RE:FINISH PLANS �p 3. UNLESS NOTED OTHERWISE ALL GWB WALLS SHALL HAVE A 6"STUD S28 FRAME RETURN AT ALL DOOR AND WINDOW JAMBS. - 4. RE:INTERIOR ELEVATIONS FOR LOCATION OF FIXTURES AND EQUIPMENT NOT N07ED ON PLANS. /-� S. FOR WALL TYPES COORDINATE WITH FLOOR PLANS AND DRAWING AND CODE INFORMATION SHEET. QDE• T---�I, C NTROLROOM d 6. PROVIDE BACKING BEHIND TYPICAL SURFACE MOUNTED EQUIPMENT " 1 H1242A 'C 6 ,�, AND/OR FIXTURES.RE:DETAIL 5IA8.52. 1 1 i tO.S '� it 1 p I 4'L Oy 10 1,14 S385L 8 7. RE:DOOR HARDWARE SCHEDULE FOR HARDWARE GROUP INFORMATION. 8. RE:DOOR SCHEDULE SHEET FOR DOOR TYPES. u +•� ��,._ �1 __J� n 9. SCREENED LINES REPRESENT EXISTING WALLS,DOORS,WINDOWS,ETC. A8.51 28.03 TO REMAIN. O 10.38 10. AT ALL OUTSIDE EXPOSED COUNTERTOP CORNERS PROVIDE 2"RADIUS 20F '1i A8.57 4 ANGIO LAB--- T--�1 4 5351 H1242 11. WHERE NEW WALL CONSTRUCTION ABUTS EXISTING WALL J y it n 70 rr, -I CONSTRUCTION,CONTRACTOR TO MODIFY EXISTING WALL Hill Q 1 t 0 S368 102 ^ S2 - - - CONSTRUCTION TO MATCH CHARACTERISTICS OF NEW WALL I.E.WHERE J 1 ECLJIPMENTROOM a -O - - _ - I NEW WALL TYPE CALLS FOR SOUND ATTENUATION INSULATION BLANKET 4t AND WALL FRAMING TO DECK,ABUTTING WALL SHALL BE EXTENDED AND . �-- i1 H1241A " !1,. 7� - 1p•9'_. i,� BLANKETS ADDED. 1 1 12. UNLESS NOTED OTHERWISE,ALL COUNTERTOPS TO BE 24'DEEP. m 1 IW I 10.38- FT - 13. REPAIR ALL DAMAGE TO EXISTING WALLS TO MATCH ADJACENT FINISH. fp 1 -- - II_-_ ' II Ag,61, 7 14. FOR ADDITIONAL WALL TYPE INFORMATION SEE WALL TYPES AND LEAD 1 n 1.10 H1241A m I 31 +•10 SHIELDING PLANS,SHEETA2.1lb � qqnn 15. PROVIDE BACKING AND STRUCTURAL SUPPORT FOR ALL MAJOR _---� S38SL 1.02 W A8.61 `;= W 1 _._JI.f7p II ,µ...li�.. S78SL EQUIPMENT.COORDINATE WITH EQUIPMENT MANUFACTURER'S I -J DUAL PLANE LPB -� SUBMITTALS. y i E 2.3t8"DIAMETER PLASTIC GROMMET WITH FLUSH PLUG TYPE H 1 -� - H1241 �1 Hi NiD = ACE OR COUNTER STATION WITH OPEN KNEE SPACE C \-,il ( 1 COVER, C AS .,..w-.. - S38SL 41 �+ 1 1 - s _ I WORK STATION SURFACE E j {,L,� cv I , i MANUFACTURED BY'HAFELE"OR EQUAL AT EACH 2 r- 538E ,.oz BELOWCOUNTER Q "M o L S�, q I C g C__7 1 ts•g ^I -+oae _ 1 1 y �� J� .. o p < g ' _ � "�� •� I T ,' i> �1� _-�, ��H _J CONTROL ROOM S76SL 1.14 ,.n 11 ; ., 11 _ z LEI "o JJp�y-•��rr ^I ,.10 1 �3 H1241B/ - 1\ _ "•--. ::1: _ ' .-•,1 1 - p (-1 I L= -]-1 I � Z � m N NN i�..•1 A8.51- ,Je 1`"I L N 8Lu IVI > J io a w 5 ; 1 j>l__ --'11' •`i ,1� r"-�• � I �1-"" .� "' 0.145'X7"POWER ACTUATED FASTENER - I 1'1- 1�h A @ 16'O.C.(MAX)REFERNOE FASTENER DEFLECTION GAP u L71 1 {L �. MANUFACTURER ICBO FOR FASTENER �•• .�I �•-"' II N --I 1 10. `a I a L- _ •' 1`•� CAPACITY MINERAL WOOL OR CEMENTITIOUS FIRE PROOFING 00 - a,l„ , ,,11 /I , , , �, I °11� - - B37S ,D.38 �• 111j 's' v 111 11/ate \ , TFl r' A8.6, H #15 310 ,.09 ,.,4 s36SL pB wAFERHEAD \ I _d 1_-•__ 1 - - S- �451_ 1I -�_ �� 11 v1241C S1B61S4L III H r FIRE-RESISTIVE CAULKING.1.114' FRAMING L SUPPORT PLATE.COORDINATE EOUIPMENTCL PROJECT DATE NOMINAL JOINTMOTH.ill MIN., 3 1.T4'MAX (SCREWS TYP.) 15008 5232 015 �p - 1242B ----- SUPTRACK 10. KED _ - l 1 ' •'' ' �^ -- ..'�1 I� II III \�\ � I 1 STORAGE 1 C"'- 1 y� y_ WHERE E EETRAOTICONS WITH MECHANICAL DRAWINDINATE DUCT AND GS SEAL - - SLOTTED TRACK CB DRAWNPER SLP-TRK BRAND JS EC T'} 1 1 i '"1" PENETRATIONS WITH THROUGH PENETRATION FIRE _ H7241C 1 � '� �`-� STOPPING ASSEMBLY. i' i 1 1*SHAFT LINER 7 1 - -1.10 531SL Y i', REVISED: p # Deeed lion Date 1.OB SHAFT WALL STUD OR WALL UCTION WHERE WITH OCCURS, 1 •t• ----- -- ., SUPPORT BEAM.COORDINATE 1 �S313L 1'� COORDINATE WALL CONSTRUCTION WITH PLANS -------------- WITH STRUCTURAL DRAWINGS. AND WALL TYPES 5/0"GYPSUM BOARD. ' 2 FRAMING DETAIL 2 HR RATED ASSEMBLY) Sq A2.11a 1 1/2'=1'-0" --- KEYPLAN 7A SHEET TITLE 6A FLOOR PLAN EXISTING TENANT/ SPACE TO REMAIN j LEVEL 1- FLOOR PLAN A2.11a 1/4"=1'-0" SHEET a AREA OF WORK Q '.11-a o / `i( a N N O N 0 b .. .. . .. .. .. . . . .. . .. . . . . . REFERENCE NOTES Q 1.03 LEAD LINED DOOR AND FRAME. 1.04 APPLY.SECOND LAYER OF LEAD SHIELDING TO EXISTING 113T LEAD SHIELDED WALL WALL IS TO BE I/16'LEAD SHIELDING, 1.05 LEAD LINED WINDOW AND FRAME, 1.07 APPLY LEAD SHIELDING TO INFILLING WALL. 1.08 ADD LAYER OF 1132"LEAD SHIELDING OVER EXISTING RATED WALLTO T-0' A.F.F.ADD 1 LAYER OF 518'GYPSUM WALL BOARD OVER LEAD SHIELDING TO 6"ABOVE CEILING.COORDINATE WITH LEAD SHIELDING PLANS.PATCH AND REPAIR DAMAGED AREAS TO ORIGINAL STATE. 2.13 EXISTING LEAD SHIELDED WALLS TO REMAIN UNCHANGED, 2.14 EXISTING LEAD LINED DOOR AND FRAME TO REMAIN. GENERAL NOTES ' ALL 1. ALL SHIELDING REQUIR2015. RE PER THERAPY PHYSICS INC. 1 MGR OFFICE/ REPORT GRAFTED 3114l2015. HJ4651 1 2. THE RECOMMENDED SHIELDING IS THE MINIMUM THICKNESS REQUIRED. Q �- 3. THE LEAD SHIELDING SHALL EXTEND TO A HEIGHT OF 7-0'MINIMUM ABOVE THE FLOOR LEVEL 4. DOORS AND FRAMES REWIRE THE SAME LEAD EQUIVALENCE AS SPECIFIED FORE WALL 5. WINDOWS REQUIRE THE SAME LEAD EQUIVALENCE AS SPECIFIED FOR THE WALL. 6. SEE FLOOR PLANS FOR ADDITIONAL INFORMATION PERTAINING TO THESE ROOMS. 7. ALL JUNCTION BOXES AND OTHER PENETRATIONS IN LEAD LINED WALLS MUST BE LINED WITH EQUIVALENT THICKNESS OF LEAD WITH _ OVERLAPPING LEAD EDGES,NO GAPS IN LEAD LINING. 8. FOR LEAD THICKNESS'S OF 1/3Y OR LESS,THE STEEL DOOR FRAMES DO NOT NEED LEAD LINING.FOR DOORS IN WALLS WITH LEAD THICKNESS'S OF 111S'OR GREATER,THE STEEL DOOR FRAMES MUST BE LEAD LINED 1 WITH THE SAME THICKNESS OF LEAD AS THE WALL 1 LEGEND CONTROL ROOM ; • �/ I H124212A 2M(1132'(LEAD SHIELDING B 1 1.03 1 4#(1/161 LEAD SHIELDING 20F I EQUIPMENT ROOM 2.13 I .�� ; - 1.58mm LEAD WINDOW Ht?A1A '`A 1 1 1 1 I 1 1 214 ; C ,.03 O 1 ❑A C 1.06 /� Q 1 ; b rt\•�,• 1 J I — G m 1 1 1 , 1 A 1.07 1 C O 1 1 Lu J m 1.04 A 1 1 � / ANGIO LAB � W WC5 m 1 H1242 cl Ov U o Ix Z D�o 1 T� I DUAL PLANE LAB 1 I ; _..I W a w --.- H1241 1 CONTROL ROOM 1 > J J,coc- H1241B s• - OLED 13 1 MGR '^ Co ALL St Luke's 1 _ 1 C .03 1 1.08 EQUIPMENTCLOSE B 1 1 r#15-310 1 H7242B J _ 1 Lai PROJECT • 1 I 1 PROJECT DATE 15008 5-25.2015 STORAGE H1241C L CB DRAWN CHECKED 2.13 1` is REVISED.A, # Description Datc Z13 1 • 1 RA 7A 6A KEYPLAN SHEETTITLE 1 LEVEL 1- SHIELDING PLAN LEAD / SHIELDING EXISTING TENAN PLAN / PACE TO RE A[ SHEET a AREA OF WORK A2:1-1 b N N O �O DOOR TYPES AS SCHEDULED DOOR SCHEDULE REFERENCE NOTES O 1Y2"=,'-0" DOOR FRAME DER 1.01 APPLY LEAD SHIELDING WHERE REWIRED.RE:LEAD SHIELDING PLAN, AS SCHEDULED DOOR TYPE WIDTH HEIGHT MATERIAL FINISH TYPE MATERIAL FINISH HARDWARE REMARKS 5.01 METALSTUD.REFERENCE FLOOR PLANS FOR WALL TYPES, AS SCHEDULED EO EO 7.05 JOINT SEALANT -} H12418 F 3'-0' T-0' EXISTING EXISTING EXISTING EXISTING EXISTING 4 EXISTING SALVAGED DOOR N BE WINDOW 8.01 HOLLOW METAL FRAME AS SCHEDULED.RE:FLOOR PLANS,DOOR H1241C NV 3-0' T-0' WD PLd 51 HM P-3 1 LEAD LINED DOOR,FRAME AND WINDOW SCHEDULE AND FRAME TYPES. H1241C NV 3-0' T•0' WD PLd 51 HM P-3 1 LEAD LINED DOOR,FRAME AND WINDOW 8.04 GLAZING STOP. b H1241D W T-0' T-0' WD PLd 51 HM P-3 1 LEAD LINED DOOR,FRAME AND WINDOW 8.05 LEAD SHIELDED GLASS.RE:SHIELDING PLAN 8.05 H1242A 2-F 8-0- T-0' WD PLd Si HM P3 2 LEAD LINED DOOR 8.06 WOOD DOOR,RE:FLOOR PLANS,DOOR SCHEDULE AND TYPES. H1242B 2•F S-O' T-0' WD PLd S1 HM P-3 3 9.04 5/r INTERIOR TYPE 7C GYPSUM WALL BOARD H1242C NV 3'-0' T-P WD PLd S1 HM P-3 5 b pp 4( is s�-,� d4���4 � A-A, . N.p GENERAL NOTES 0 1. ALL HOLLOW METAL FRAME SIDE OPPOSITE FROM HALLWAYY//ICORRIDORNG STOPS TO REPLACED ON ROOM Y �x w 2. PROVIDE FULLY TEMPERED GLASS UNITS WHERE REWIRED BY I.B.C. !2 3. 2406. S~ LLo 3 ALLDOORSS TNGFORFI BE NISHSUREE.DECORATIVE LAMINATE.REFERENCE FINIStwo 7 ABBREVIATIONS ALUM -ALUMINUM FF -FACTORY FINISH AS SPECIFIED HM -HOLLOW METAL HPC -HIGH PERFORMANCE COATING M MINUTES P4 -PAINT CWOR'NUMBER'(RE:DIVISION SECTION"INTERIOR PAINTING'. WD -WOOD S SMOKE AN -ANODIZED DOOR HARDWARE FRAMETYPES HARDWARE SCHEDULE 112"_1.4. SET:1.0 2' 2. 10-0' 1 CONTINUOUS HINGE MCK-FM300 US32D MK 1 PASSAGE SET 748215 LNL US26D SA SCHEDULED 2" 4'-9' 2' 4'-9' 2' DIPS EN SA 1 KICK PLATE OR ER K10501V US32D RO '..� i PK A701 2 1 STOP 415M81H(AS REWIRED) US26D RO 3 SILENCER RO A7.01 1 SMOKE SEAL PK 55 PE O SET, Q 2 CONTINUOUS HINGE MCK-FM300 US32D MK J 2 PUSH PLATE 70F US= RO p 2 PULLPLATE 111:70C US32D RO A7.01 1 AUTO OPERATOR 9500SERIES 689 LC tv b O O 2 ARMOR PLATE K705036' US32D RO 1 _ - SIM. 805 805 2 STOP 416148111(AS REWIRED) US25D RO o A7.Ot 2 SILENCER 608 RO 2 ACTUATOR 505 NO SIM, 0 1 SMOKE SEAL PK 55 PE ,o F SET:3.0 � a c 3 6 HINGE TA2714 US26D MK (~/� _J m 2 ROLLER LATCH 592 U826D RO W L!J m N A7.01 2 PUSH PLATE 70F US32D RO 3 a 2 PULL PLATE 111x70C US RO Q �m 2 SURFACE OH STOP 14X36 32O 630 RF 2 SILENCER 608 RO 1 SMOKE SEAL PK55 PE Q of o 2- SET,4.0 w Lu 1 HARDWARE REUSE EXISTING co 2 c� N N S1 O SEN CONTINUOUS HINGES MCK-FM300 US32D MK O 1 PASSAGE SET 748215 LNL US26D SA J a-- 1 DOOR CLOSER 351 DIPS EN SA 1 KICK PLATE K105010' US32D RO � 1 SURFACE OH STOP 1DX36 630 RF 1 SMOKE SEAL PK55 PE 3 SILENCER 6W RO 1 LLSt Luke's #15-310 PROJECT DATE 5.01 15008 5232015 Y: 904 DRAWN CHECKED BOTH SIDES 805 CB JS 7,05 a BOTH SIDES REVISED: N ALL AROUND,BOTH SIDES 8.04 # Description Date 7.05 801 ALL AROUND,BOTH SIDES 8.01 8.06 1.01 8.01 t!; 8.D4 7.05 ALL AROUND,BOTH SIDES I t"t SD4 g,05 BOTH SIDES V:v 601 SHEET TITLE DOOR 1 HEAD DETAIL 01 (JAMB SIM.) 2 HEAD DETAIL 02 JAMB SIM. 3 SILL DETAIL 01 (JAMB SIM.) SCHEDULE, A7.01 6„=V-0„ A�.o, 6„ 1,= -0" TYPES AND DETAILS SHEET a N A7.01 II REFERENCE NOTES 0 _ I 9.17 TRANSITION FROM EXISTING LF-1 TO NEWSV-1.REPAIR ANY MATERIAL DAMAGED IN WALL OR FLOOR DEMO. 00 II 9.19 CG1.SEE ROOM FINISH(CASEWORK SPECIFICATION INFORMATION. I 1 1 I FF.1 I / / HALL I �U LLo H1464 9.17 d 77 917 1 ABBREVIATIONS-FINISHES TROL ROOM FLOOR FINISHES 20E H1247A SV SHEET VINYL l� WALL BASE 20F 1 1 919 RWB RUBBERWALLBASE 1 WALL FINISHES IEQIIPMENTROOM P PAINT I H1241A a — = / _ CEILING I 9.19 / GLa" � APC ACOUSTICAL PANEL CEILING CONTROL CASEWORK H12tl8 / Pt PLASTIC LAMINATE WP WIRE PULL HARDWARE CO / WT WOODTAPE - I DUAL PLANE LAB ANGIO LAB I I H1241 9.19 H1242 / 9.19 9.19 STORAGE O 2013 1 H1241C I � L ❑1 EQUIPMENT H1-1 OSET J H1242B I 1 9 m � b m 7A W WC m N 1 LEVEL 1- FINISH FLOOR PLAN U o o A8.01 1/8"=1'-0" Zw .o0 N Z 2N07 NN o ROOM FINISHICASEWORK SPECIFICATION INFORMATION: SCHEDULE-ROOM FINISH U) ACOUSTICAL CEILING PANEL PLASTIC LAMINATE-HORIZONTAL SURFACES FLOOR WALLS CASEWORK MANUFACTURER:ARMSTRONG PL•1 MANUFACTURER:WILSONART Level ROOM NO. ROOM TITLE MAT. BASE NORTH EAST SOUTH WEST CABINETRY COUNTER TOP REMARKS ALL s ` �S STYLE:CORTEGA STYLE:OATMEAL FIBER,AT101 1 PROFILE:SQUARE LAY IN#769 NOTE:USE WITH WTA 3MM PVC #15-310 NRC:0.55 LEVEL 1 H7241 DUAL PLANE LAB SV-1 RWB4 P•11PL-3 P-UPL-3 P-11PL-3 P-VPW PL-2 PL-1 1,3 FIRE RATING:CLASSA(UL) PLASTIC LAMINATE-VERTICAL SURFACES LEVELI H7241A EQUIPMENT ROCM SV-1 RVJB-1 P-2 P-2 P-2 P-2 PL-1 2 WEIGHT..fi1 LBS/SF PL-2 MANUFACTURER:WILSONART LEVEL H7241B CONTROL ROOM I SV-1 RW&1 - P-2 - P-2 - PL-1 2 COLOR WHITE STYLE:SHAKER CHERRY,7835-07 LEVELI H1241C STORAGE SV-1 RWB-1 P-2 P-1/PL-3 P-2 PL-1 12 PROJECT DATE SIZE:24'X 48" NOTE:USE WITH WT-2 LEVELI H1242 ANGIO LAB SV-1 RWB•1 P-11PL3 P•11PL-3 P-11PL-3 P-11PL-3 PL-2 PL-1 1,3 15006 5-2&2015 GRID:1&16"PRELUDE,WHITE PLASTIC LAMINATE•WALL PROTECTION LEVELI H1242A CONTROL ROOM SV-1 RW61 P-IIPL3 - P-2 - PL-1 1,2 DRAWN CHECKED ACOUSTICAL CEILING PANEL PL-3 MANUFACTURER:FORMICA LEVELI H72428 EQUIPMENT CLOSET SV-1 RW&1 P-2 P-2 P•2 P-2 PL-1 3 MS KH MANUFACTURER:ARMSTRONG STYLE:SEED WEFT 5877-58 STYLE:CLEAN ROOM NOTE:METAL J-CAP FINISH AT TOP AND OPEN ENDS PROFILE:#1716 p NRC:0.55 PLASTIC LAMINATE-DOORS REVISED: # FIRE RATING:CA ILL) P41 MANUFACNRER:NEVAM4R REMARKS: WEIGHT:1,02 L STYLE:SANTA ROSA PLUM TREE WZZD0IT,TEXTURED. 1. PL-3 WALL PROTECTION T046H ALONG ENTIRE LENGTH # DeaeripEon Date COLOR:WHITE NOTE:MATCHES EXISTING DOORS SIZE:24'X 48' OF WALL EXCEPT AT COUNTERTOPS.INSTALL METAL J-CAP GRID:15A6'PRELUDE,WHITE RUBBER WALL BASE FINISH AT TOP AND OPEN ENDS, RW&1 MANUFACTURER:JOHNSONITE 2. ACP-1THISROOM. CORNER GUARD STYLE:6'COVE BASE 3. ACP-2 THIS ROOM. MANUFACTURER:CS INTERIORS COLOR:MYSTICAL 276 PRODUCT:ACROVYN WALL PROTECTION CG1 STYLE:SM-20,ACROVYN 3000 SHEET VINYL SQUARE NOSE PROFILE,3'WIDE MANUFACTURER:JOHNSONITE COLOR:521 SPANISH MOSS SV.1 PRODUCT:TARKETT RUBY NOTE:ALL CORNER GUARDS TO BE MOUNTED COLOR:AMBER GLAZE 032 FROM FINISHED FLOOR TO 48'ABOVE THICKNESS:0.08' FINISHED FLOOR. DIMENSIONS:6-7 X 76 SHEET ROLL LINOLEUM FLOORING NOTE:USE WELD ROD 127153 ' MANUFACTURER:ARMSTRONG WIRE PULL HARDWARE LF-0 STYLE:MARMORETTE IMP., DESCRIPTION:4'SATIN NICKEL WIRE PULL PRODUCT#:LS070 NOTE:INSTALL HORIZONTAL AT DRAWERS AND COLOR:BAMBOO TAN VERTICAL AT CABINET DOORS. DIMENSIDNS:6.5 FT X 98.4 FT X 0.100' SHEET TITLE NOTE:WELDING ROD-GOLDEN BLUFF W1070 WOOD TAPE ROOM FINISH MANUFACTUER:REHAU WALL PAINT WT4 STYLE:FLEXEDGEBANDING P•1 MANUFACTUER:SHERWIN WILLIAMS COLOR:CABINET ALMONDC2D0261 SCHEDULE COLOR:HERBAL WASH SW 7739 NOTE:3MM.USE WITH PL-1 FINISH:SATIN WOOD WALL PAINT MANUFAPE AND PLAN ANUFACTUER:DOEl1JU:N-WOODTAPE ' R2 MANUFACTURER:BENJAMIN MOORE W7-2 STYLE:3074-15151 COLOR:POWELL BUFF HC-35 SUPER SPEC DIMENSIONS:15116'z.018' FINISH:PEARL NOTE:USE WITH PL-2 DOOR FRAME ANO WINDOW FRAME PAINT SHE-T � MANUFACTURER:BENJAMIN MOORE COLOR:DECATUR BUFF HG38,SUPER SPEC FINISH:SEMI-GLOSS a A8.01 0 REFERENCE NOTES O 1.13 RE-LOCATED CATH PACK RACK COORDINATE WITH OWNER. 7024 1.15 TERMINATE HALF WALL UNDER COUNTER I'FROM EDGE OF _ COUNTERTOP. --_-'_i 6,10 1.17 MILLWORK CONTRACTOR TO PROVIDE BID FOR EQUIVALENT CABINET TO I 10.39 I i 10,33 i ` MATCH STANLEY BASIS OF DESIGN, 10.30 w O10.382.01 EXISTING CONSTRUCTION,PRESERVE AND PROTECT,REPAIR DAMAGED 1026 10 102810. 1026 10.26 10.27 1028 102A t i 10.30 \ AREASTOIX2IGINAL 6TATE. 610 6.10 1-1/4'THICK COUNTERTOP.SEE FINISH DRAWINGS FOR FINISH MATERIAL 5 1, '•M f. Ab52 O ` 620 1/8'THICK BLACK POWDER COATED STANDARD STEEL COUNTERTOP SUPPORT BRACKET TO EXCEED 1,OOD1B LOAD CAPACITY,SUPPORT TO ®I ® ®® I ®� b rBE EQUALLY SPACED AT3'-0'O.C.MAX.WHERE OCCURS,RECESS 1"b FROM END OF COUNTERTOP. ®I mI 1 TYP. -1 T6.32 3N'PLASTIC LAMINATE WRAPPED PANEL CORE ENCLOSURE PLANEL. COORDINATEWITHENCLOSURE PANEL DLTAIL ON INTERIOR ELEVATIONS AND DETAILS SHEET.SEE FINISH DRAWINGS FOR FINISH MATERIAL 6.41 1023 g6.20 1.15 620 g 6.41 9 ,05 10.25,. TYP 620 10.31 10. 10,31 6.� 6.37 BASIS OF HEALTHCARE CASEWORKTAVE A 4-5136DGA-CC TOSE USED ASA � H TYP. /eD 10' A8.52 TYP• 10. BASIS OF DESIGN.CABINETS TO HAVEA4'BASE.RE:DETAIL I VAB.51.19 6.38 STANLEY HEALTHCARE CASEWORK MODEL 5118LGA-VC TO BE USED AS A ~ o BASIS OF DESIGN.CABINETS TO HAVE A 4'BASE.RE:DETAIL 10/A851. ' 18'-4' 6.39 STANLEY HEALTHCARE CASEWORK MODEL 51181 TO BE USED AS •C BASIS OF DESIGN.CABINETS TO HAVE A 4"BASE,RE:DETAIL 10/A8.51 a / e CONTROL ROOM H12416 6.41 RECESSED COUNTERTOP.SEE FINISH DRAWINGS FOR FINISH MATERIAL y 2 CONTROL ROOM H1242A EQUIPMENT CLOSET H1242B a EQUIPMENT ROOM H1241A ANDDETAILS/A8.52. 1/4"=1'-O° 10.04 WALL MOUNTED PAPER TOWEL DISPENSER,BOBRICK,B-2620.REFER TO A8.51 A8.51 1/4"=1'-0" A8.51 1/4"=1'0" A8.51 1/4"=1'-0' DRAWING 8 BUILDING INFORMATION SHEET. 10.05 O,F.0.1.WALL MOUNTED SOAP DISPENSER. 324M 1023 DIGII FLUOROGRAPHY CONSOLE CONTROL INTERFACE BOX. COORDINATE WITH MEDICAL EQUIPMENT MANUFACTURER. 37 13 10.24 MICROPHONE AMPLIFIER COORDINATE WITH MEDICAL EQUIPMENT _ MANUFACTURER. .324 13. NO VERTICAL DIVIDERS 323tit 32< 4 13" 30'324 13' 14'O13' 10.25 ANGIO WORKSTATION,COORDINATE WITH MEDICAL EQUIPMENT MANUFACTURER DRAWINGS 6,32 B32 14' 13' pg. 24. 24. 10.26 LCD MONITOR WITH STAND.COORDINATE WITH MEDICAL EQUIPMENT NOVERTICALDIVIDERS NO VERTICAL DIVIDERS NO VERTICAL DIVIDERS NO VERTICAL DIVIDERS MANUFACTURER. I ERTICAL DIVIDERS 10.27 MAIN CONTROL CONSOLE.COORDINATE WITH MEDICAL EQUIPMENT MANUFACTURER DRAWINGS, 632 6.32 8.32 6.32 10.30 INNERVISION WORKSTATION.COORDINATE WITH MEDICAL EQUIPMENT J. MANUFACTURER, _ 10.31 WATER COOLING UNIT.COORDINATE WITH MEDICAL EQUIPMENT IL.-.. a `. 10.04 MANUFACTURER. IL `� �� �� �'I 10.32 COOLANT CIRCULATOR.COORDINATE WITH MEDICAL EQUIPMENT _ ..n MANUFACTURER ( m- 10.05 r I I b b I 10.33 RAID MACHINE.COORDINATE WITH MEDICAL EQUIPMENT 6.10 ®m i _ gm I® MANUFACTURER. 10.39 WALL MOUNTED MONITOR AND VIDEO EQUIPMENT.PROVIDE BACKING L 1043 W PLATE,COORDINATE WITH MEDICAL EQUIPMENT MANUFACTURER'S ® ( Irg�l' i ®® I I DRAWINGS. M L_JI I 10.43 OMNICELL UNIT, O 26.05 ACCESS PANEL COORDINATE WITH MEDICAL EQUIPMENT MANUFACTURER'S DRAWINGS. f 1.13 8,38 8.37 8.37 3'-9" 1'•8' Q 420M ''' �'- 6,37 -�'---�'-Itj106" ?a' 1522212"xi2'EQCUBBIES 1.17 1.17 117 32' �. 24' 37 �, 24' 636 117 J GENERAL NOTES REMOVABLE PANEL 26' 18 1. RE:ROOM FINISH SCHEDULE AND FINISH FLOOR PLANS FOR MATERIAL 3q 1,17 AND FINISH INFORMATION, e STORAGE 1241 C- EAST s DUAL PLANE LAB H1241 -WEST � ANGIO LAB H1242- EAST 2. ANDALLMEESPACESA BE BELOW CABINET CABINET6,SIDES OF CABINETS AND ALL IQJEE BELOW CABINETS. 3. RE:FLOOR PLANS AND DOOR SCHEDULE FOR DOOR AND FRAME TYPES, A8.51 1/4°=1'-0" A8,51 1/4'=1'-0" A6.51 1/4"=1'-0" 4. UNLESS NOTED OTHERWISE,ALL COUNTERTOPS TO BE 1-1/4'THICK, WHERE SINK IS PROVIDED,INSTALL 4'HIGH BACKSPLASH.COORDINATE WITH FINISH DRAWINGS. 5. DOOR LOCKS TO BE BHMA A156.11,E07121.DRAWER LOCKS TO BE J'� BHMA 156.11,E07041.PROVIDE M KEYS PER LOCK AUTOMATIC DOOR m BOLTS:HAFELE#530-1604 OR EQUAL,USED TO SECURE INACTIVE DOOR j W ON ALL LOCKED CABINETS, 3?AM 6. ATALLEXPOSED OUBIDE COUNTERTOP CORNERS PROVIDE 2'RADIUS. /� 0 m Mo 3T ' 32' - 7, COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR U Q t t a rn NO 28 28 ADDITIONAL INFORMATION, Q 6. PROVIDE CONCEALED HINGES(EUROPEAN TYPE):170 DEGREES OF Z v q m VERTICAL DIVIDERS NOVERTICAL DIVIDERS OPENING.AND SELF CLOSING AT ALL MILLWORK �n y G W to 10. SHELF RESTS TO BE 5MM DUAL PIN. Z N N 6.32 9. EDGE BANDING TO BE 1.3MM PVC. N 11. UPPER CABINETS TO BE PROVIDED BY MILLWORK CONTRACTOR. - 201 10.26 CASEWORK TAG LEGEND 0 NUMBER INDICATES00 MODIFIED S20 WIDTH y3�6'-DEPTH 36-eMa ®I Eztra Shelf HEIGHT L MODIFICATION r-St Luws r•olrr DESCRIPTION #15-310 z.ot fi.zo MODEL INDICATES MODEL NUMBER BASED ON AN NUMBER CDS NUMBERING SYSTEM PROJECT DATE INDICATES INDICATES A MODIFIED VERSION OF THE 15008 5-29.2015 MODIFIED AN CABINET MODEL REPRESENTED BY )RA, CHECKED IM THE PRECEDING NUMBER. CB JS $ AL PLANE LAB H1241 NORTH �CONTROL ROOM H1242A- EAST MODIFICATIQN A DESCRIPTION OF THE MODIFICATION A8.51 1/4"=1'-0" A8.51 1/4'=1'-O" DESCRIPTION MADE INDICATED BY THE(M)FOLLOWING THE MODEL NUMBER REVISED: # WIDTH INDICATES THE NOMINAL OUTSIDE # Desonption Date DIMENSIONAL WIDTH OF THE CASEWORK imn-efsoffe-e. �� ' 1 I, DEPTH INDICATES THE NOMINAL OUTSIDE Fm -, DIMENSIONAL DEPTH OF THE CASEWORK INDICATES THE NOMINAL OUTSIDE Product Description HEIGHT DIMENSIONAL HEIGHT OF THE CASEWORK. v,-.w,. Product Description w-Yn, WHERE COUNTERTOP OCCURS DIMENSIONS 5� ARE TO TOP OF COUNTERTOP FROM FLOOR�a�,. .""ems� ��+•v ..e r""�.a .omo,,:va wm, �S �o,u F�,� v •�+„wN a+an.w+++r� car«" w,.w.` �,,.�.a�v�v"`1e..a,. A °"u- ' Prouuct Specifcations IL �rIIISpecifications"...n�i�--'� SHEET TITLE - INTERIOR ELEVATIONS r , SHEET a aotw 10 5118LGA CABINET DETAIL 11 5136DGA CABINET DETAIL A6.51 6,=1,0„ o A8.51 F-1-0 m NOTE PROV DE TER CLOSUREA ANGLE. ONE END REFERENCE NOTES O CLOSUREANGLE.ONE END OF THE CEILING GRID RNETMETAL ANGLE SHALL BE ATTACHED TO THE CLOSURE ANGLE ON EDGE TO T4MR@ 1.16 RECESSEDCOUNTERTOP TO EXTEND THE LENGTH OF THE WINDOW TWOADJACENT SIDES.THEOPPOSITEENDS 24'O.C. ABOVE FROM JAMB TO JAMB. SHALL HAVE A 3/4'CLEARANCE FROM THE WALL HEAVY-DUTY AND SHALL REST UPON AND BE FREE TO SLIDE ON HEAR GRID SYSTEM VERTICAL HANGER 2.01 EXISTING CONSTRUCTION,PRESERVE AND PROTECT.REPAIR DAMAGED CLOSURE ANGLE. WIRES 4'-0"OC 1518'STUD AREAS TO ORIGINAL STATE. FOR COMPRESSION 2.06 EXISTING WALL SYSTEM.PRESERVE,PROTECT AND REPAIR DAMAGED CEILING PANEL SLIP SPLAY HANGER WIRE AREAS TO ORIGINAL STATE. JOINT(NO RIVET) AT 124r O.C.EACH 2.19 REMOVE EXISTING GYPSUM WALL BOARD WHERE DUCT FUR OUT PLANE,EACH RUNNER 2"MIN CONDITION OCCURS.TYPICAL 5.06 21/2"STEEL STUD. 518"GYP.BD. CHANNEL @ 48"O.C. / 6.20 1/8"THICK BLACK POWDER COATED STANDARD STEEL COUNTERTOP III SUPPORT BRACKET TO EXCEED 1,DOPLB LOAD CAPACITY.SUPPORT TO 314'MIN. BE EQUALLY SPACED AT 3'-P O.C.MAX WHERE OCCURS,RECESS V FROM END OF COUNTERTOP. b' 45 deg.MAX 45 deg.MAX 6.40 UNDER COUNTER SUPPORT.RE:DETAIL 10/A8.52. �y BAI RECESSED COUNTERTOP.SEE FINISH DRAWINGS FOR FINISH MATERIAL 4 - LAY-IN ACOUSTIC // AND DETAIL 9/A8.52 8 2• 2' CEILING PANEL 8.01 HOLLOW METAL FRAME AS SCHEDULED.RE:FLOOR PLANS,DOOR o SCHEDULE AND FRAME TYPES. ING PLAN 24'O.CT CHANNELS SCHEDULED 2"MIN WALL � � P 4Yq�NRLNNFR 9.04 518'INTERIORE TYPE'X'GYPSUM GLASS.RE: WALL BOARD 26.D4 WALL MOUNTED DUCTING,COORDINATE WITH MEDICAL EQUIPMENT MANUFACTURERS DRAWINGS. SUSPENDED CEILING DETAIL 2 TYPICAL LAY-IN CEILING TILE EDGE DETAIL 3 TYPICAL SEISMIC BRACING DETAIL-01 A8.52 3"=1'0" A8.52 3"=1'-0' A6.52 12"=r-0" GENERAL NOTES 1. RE:ROOM FINISH SCHEDULE AND FINISH FLOOR PLANS FOR MATERIAL AND FINISH INFORMATION. 2 PROVIDE RWB ATALL TOE SPACE OF ALL CABINETS,SIDES OF CABINETS AND ALL KNEE SPACES BELOW CABINETS 3. RE:FLOOR PLANS AND DOOR SCHEDULE FOR DOOR AND FRAME TYPES, 4. UNLESS NOTED OTHERWISE,ALL COUNTERTOPS TO BE 1-1/4'THICK. WHERE SINK IS PROVIDED,INSTALL 4'HIGH BACKSPLASH,COORDINATE WITH FINISH DRAWINGS. FIRSTLINEOF 5. DOOR LOCKS TO BE BHMAA156,11,E07121.DRAWER LOCKS TO BE 3 BRACING 4'-T OR METAL SryDS MOUNTED SHMA 156.11.E07041.PROVIDE(2)KEYS PER LOCK AUTOMATIC DOOR ae.6z LESS FROM WALL TO DECK ATAB'O.C. BOLTS:HAFELE#530.1604 OR EQUAL,USED TO SECURE INACTIVE DOOR BOUNDARY ON ALL LOCKED CABINETS. 6. AT ALL EXPOSED OUTSIDE COUNTERTOP CORNERS PROVIDE T RADIUS. ' CEILING 7. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR SUSPENSION SYSTEM ADDITIONAL INFORMATION. METAL STUDS.REFERNCE 8. PROVIDE CONCEALED HINGES(EUROPEAN TYPE):170 DEGREES OF FLOOR PLANS FOR WALL 3 OPENING,AND SELF CLOSING AT ALL MILLWORK. 4 TYPES. 9. EDGE BANDING TO BE 13MM PVC. I 8.0.CEILING 10. UPPER CABINETSTO BE PROVIDEDN. BY MILLWORK CONTRACTOR. I - RE:Rc� 2X FIRE TREATED CEILING SYSTEM AS SCHEDULED INTERIOR PARTITION-SEE WALL TYPES Q WA Q\ I I SOLID BLOCKING CEILINGS S E OPPOSITE DIFFERENT J q'l I I SOUND INSULATION,WHERE OCCURS- p HEIGHTS-SEE REFLECTED CEILING PLAN) SEE WALL TYPES II II m m a TYPICAL SEISMIC BRACING DETAIL-02 5 TYPICAL MOUNTING PLATE ELEVATION DETAIL s TYPICAL SEISMIC BRACING DETAIL AT PARTITION WALLS A8.52 12"=1'0" Lu LLu N Q L m O N O �p9 no Lu T�z Z Z -+-Nm NN CV � a� B.oS > Lu -1 t 2-6" 8.01 cI i 6.10 VJ 00 tI I 10, .i is io I i. 1.18 6.41 A6r St Lukes #15-310 PROJECT DATE (�3`4`PANEL CORE. COUNTERTOP.RE: 15008 5-29.2015 RE:FINISH PLANS FOR 1'-101/? i o INTERIOR ELEVATIONS COUNTERTOP.RE:INTERIOR VARIES i i• 6.20 < i1,1 F FINISH MATERIAL _ � w i- I I, a AND DETAIL 9/A8.52. 41/C DRAWN CHECKED i' w �f� ELEVATIONS AND DETAIL 9/AB.52. CB JS LINE OF CEILING.COORDINATE 26.04 i - -1 6.40 WITH REFLECTED CEILING I PLAN REVISED: # 314'PLASTIC LAMINATE WRAPPED �'1 i i. ��;� w a I, .� �, �, o (2)'14'PANEL CORE. # Description Date PANEL CORE ENCLOSURE PANEL. 1 rc F RE:FINISH PLANS FOR i SEE FINISH DRAWINGS FOR FINISH 1i i;) i FINISH MATERIAL. MATERIAL rn o CASEWORK BELOW.COORDINATE 2.01 `i i i i� 9.04 �'� �i i I: i i' 9.04 WITH INTERIOR ELEVATIONS ' 3r4'PANEL CORE.RE: FACE OF WALL COORDINATE i 201 3r4' FINISH PLANS FOR WITH FLOOR PLANS - i 34'PANEL CORE RE: FIN MATERIAL. Y a• ,- w- ,•9; 1112 1112'FINISH PLANS FOR $ n 41/Y FINISH MATERIAL. LINE OF FLOOR � CLOSURE PANEL DETAIL s TYPICAL WALL DUCT DETAIL @ COUNTERS s TYPICAL WALL DUCT DETAIL @ RECESSED COUNTER 10 COUNTER SUPPORT DETAIL TYP. SHEET TITLE A8.52 1"=1'•0" A8.52 1 1@"=1'-0" Aa.52 11/2'=r-o' INTERIOR A8.52 1 -1-0" DETAILS SHEET N -8 52 O ' N O REFERENCE NOTES 10.28 DUAL PLANE LAS EQUIPMENT.COORDINATE WITH MEDICAL EQUIPMENT MANUFACTURER AND STRUCTURAL DRAWINGS, 1029 ANGIO LAB EQUIPMENT.COORDINATE WITH MEDICAL EQUIPMENT MANUFACTURER AND STRUCTURAL DRAWINGS 10.40 J410X FLUSH MOUNTED IN FINISHED CEILING.COORDINATE WITH EQUIPMENT MANUFACTURER AND ELECTRICAL DRAWINGS, 10.41 X-RAY ON WARNING LIGHT.COORDINATE WITH MEDICAL EQUIPMENT MANUFACTURER AND ELECTRICAL DRAWINGS. IGENERALNOTES 1 1. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMS TO BE PROVIDED AT THE CEILING PLANE AND IN THE WORK. 2. CENTER ALL LIGHT FIXTURES AND SPRINKLER HEADS IN THEIR �n - *$ RESPECTIVE CEILING PANEL ` 3. INSTALLACL SUSPENSION SYSTEMS FOR ACOUSTICAL PANEL CEILINGS a o 4. PERALL PROVISIIT ONS OF ASTMNS C SHOWN ARE TO FACE OF FINISH. 5. COORDINATE WITH MECHANICAL 8 ELECTRICAL DRAWINGS FOR F PHYSICALSIZESOF ALL CEILING GRILLES,DIFFUSERS,FIXTURES,CANS, N AND ALL RELATED ITEMS, 8. SUSPENSION SYSTEMS FOR GYPSUM BOARD CEILINGS SHALL BE i - - INSTALLED PER THE SPECIFICATIONS AND ASTM C754. :,,••. LEGEND 2X4'ACOUSTICAL CEILING METAL SUSPENSION SYSTEM WITH ACOUSTICAL PANEL CEILING UNITS.RE:FINISH DRAWINGS AND SCHEDULE I FOR FINISH MATERIAL. LIGHTING FUCNRES,COORDINATE WITH 10.41 0 ELECTRICAL DRAWINGS. ft IL MECHANICAL FIXTURES,COORDINATE WITH MECHAN CAL DRAWINGS. _ X-X' CEILING HEIGHT ABOVE FINISH FLOOR I .. 0 1 10,40 r QUIPMENTIR H1241A �c---- r I .40 9'-r AF.F. L—J 1 111 10 18 WJ Wmo 1 Q Lu Lu I 10.40 - 11 I N y =Lq Nm°�,�N I 1 � I IL J IL 11 I 14 II 1 0 G C/ O r I i-'f CONTROL ROOM I I I -11 III I 1 11 1 I H1z41B / � I � l I 11 I S'A.F.F. 10.40 Il c ao I UAL PLA E LI B 11 II 11 — 1 , d I 1 I 1r St LtJws I _ 1o.zs I 10.ao I 11 11 1 47 _..._ J e'•5 A.F.F:i 10 �I 0 1 r#15-310 I PROJECT DATE 5-29.2015 DRAWN CB CHECKED 1 1 110 _ r I - 1 '� 11 1 1 II I EQUIPM CLOSET REVISED: # scnption Date 1 1 I STORAGE ... . .. y _ I 10.28 I H1241C t I II I 11 9'-8'AF.F, r I k' KEYPLAN SHEET TIRE 't REF. . CTED CEILING PLAN 7A EXISTING TENAN PACE TO REMAIN SHEET LEVEL 1-CEILING PLAN M A9:01 a AREA OF WORK N O ' N O b GENERAL STRUCTURAL NOTES STRUCTURAL ABBREVIATIONS GENERAL METAL STRUT FRAMING SYSTEM O�OAe 1. CODE: INTERNATIONAL BUILDING CODE,2012 EDITION,AS MODIFIED BY W r m THE CITY OF TWIN FALLS,ID. 1. ALL METAL STRUT COMPONENTS SHALL BE MANUFACTURED BY UNISTRUT @ AT JOIST J CORPORATION OR APPROVED EQUAL AS DETERMINED BY THE ENGINEER OF AS ANCHOR BOLT JT JOINT h $ 3 Q 2. DESIGN LOADS(LION): RECORD. ACI AMERICAN CONCRETE INSTITUTION ADDL ADDITIONAL KSF KIPS PER SQUARE FOOT 2. EACH INDIVIDUAL METAL STRUT ASSEMBLY SHALL HAVE ALL COMPONENTS ADJ ADJACENT KSI KIPS PER SQUARE INCH A. FLOOR LIVE LOADS(UON): (I.E.STRUTS,FITTINGS,CONNECTORS,ETC.)PROVIDED BY A SINGLE AFF ABOVE FINISH FLOOR LOCATION: UNIFORM LOAD MANUFACTURER.MIXING COMPONENTS FROM DIFFERENT MANUFACTURERS AISC AMERICAN INSTITUTE OF STEEL L ANGLE OR L-SHAPE ELEVATED FLOORS(LION) 80 PSF IS STRICTLY PROHIBITED. AL CONSTALUMIRUCTION STAIRS 100 PSF LB(S) POUND(S)FORCE LF LINEAR FEET ALTN ALTERNATE 3. ALL BOLTED CONNECTIONS SHALL BE TIGHTENED IN STRICT ACCORDANCE LIW LOAD INDICATING WASHER B. SUPERIMPOSED DEAD LOADS: WITH THE METAL STRUT MANUFACTURER'S REQUIREMENTS. ANSI AMERICAN NATIONAL STANDARDS LL LIVE LOAD INSTITUTE LLH LONG LEG HORIZONTAL LOCATION UNIFORM LOAD APPROX APPROXIMATE LLV LONG LEG VERTICAL ELEVATED FLOORS(LION) 30 PSF(PLUS 20 PSF PARTITION LOAD) AAPVD RCH ARCHITECTURAL ECTURAL LONG LONGITUDINAL LPT LOW POINT C. SNOW LOADS: N/A-INTERIOR CONSTRUCTION ON LOWER FLOORS ASTM AMERICAN SOCIETY FOR TESTING D. WIND: N/A-INTERIOR CONSTRUCTION ON LOWER FLOORS SPECIAL INSPECTION AND MATERIALS MATL MATERIALAWS AMERICAN WELDING SOCIETY MAX MAXIMUM J 1. SPECIAL INSPECTION SHALL BE PERFORMED BY AN INDEPENDENT INSPECTION AND MB MACHINE BOLT W E. SEISMIC: NON STRUCTURAL COMPONENTS ONLY(MEDICAL EQUIPMENT) BTWN BETWEEN MECH MECHANICAL PER ASCE 7-10 CHAPTER 13. TESTING AGENCY RETAINED BY THE OWNER FOR ALL STRUCTURAL STEEL WELDING, BF BOTTOM FACE MET METAL Q AND POST-INSTALLED CONCRETE ANCHORS AND DOWELS IN ACCORDANCE WITH BLDG BUILDING MFR(S) MANUFACTURER Ss:0.56 g F":0.80 SD,:0.14 g SITE CLASS:ID CHAPTER I CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE 2012. BM BEAM MN MINIMUM 0 � a BO BOTTOM OF MSC MSCELLANEOUS 2. SPECIAL INSPECTOR SHALL SUBMIT COPIES OF ALL FIELD INSPECTION REPORTS BOT BOTTOM C p:VARIES BY COMPONENT Rp:VARIES BY COMPONENT TO THE ENGINEER.REPORTS SHALL INCLUDE LOCATION AND DETAILED BRG BEARING C M NA NOT APPLICABLE 3. DATUM: FIRST FLOOR TOC SLAB EL 100'-0". DESCRIPTION OF ITEMS INSPECTED.REPORTS OF NON-COMPLIANT WORK SHALL NIC NOT IN CONTRACT W co BE SUBMITTED WITHIN 3 WORKING DAYS OF INSPECTION. C CHANNEL NTS NOT TO SCALE n/ 4. CONTRACTOR SHALL COORDINATE ALL DIMENSIONS AND ELEVATIONS SHOWN C TO C CENTER TO CENTER LL ON STRUCTURAL DRAWINGS WITH ARCHITECTURAL DRAWINGS. 3. AT THE END OF THE PROJECT,THE SPECIAL INSPECTOR SHALL PROVIDE A CHKD PL CHECKERED PLATE OC ON CENTER SIGNED WRITTEN STATEMENT TO THE OWNER THAT SPECIAL INSPECTION HAS BEEN CJ CONSTRUCTION JOINT OD OUTSIDE DIAMETER m w 5. CONTRACTOR SHALL BRING ALL OMISSIONS OR CONFLICTS BETWEEN THE PERFORMED ON ALL REQD COMPONENTS OF THE PROJECT IN ACCORDANCE WITH CJP COMPLETE JOINT PENETRATION O.F. OUTSIDE FACE Q J o VARIOUS ELEMENTS OF THE CONTRACT DOCUMENTS TO THE IMMEDIATE 2012 IBC AND THAT INSTALLATION OF THESE COMPONENTS CONFORM TO THE (WELD) OPNG(S) OPENING(S) J LL °Doo ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING WITH RELATED WORK, CONTRACT DOCUMENTS AND RELATED CODES CLR CENTERLINE OPP OPPOSITE CLR CLEARANCE,CLEAR Z �=ty 6. VERIFY LOCATION AND SIZE OF ALL OPENINGS THROUGH FLOORS,WALLS, CMU CONCRETE MASONRY UNIT PERIM PERIMETER to to SLABS,AND ROOFS WITH MECH,ELEC,AND ARCH DRAWINGS AND WITH COL COLUMN PJF PREMOLDED JOINT FILLER F- 0:2v EQUIPMENT FURNISHED PRIOR TO PROCEEDING WITH RELATED WORK. CONC CONCRETE PJP PARTIAL JOINT PENETRATION(WELD) th 7. STRUCTURAL MEMBERS OR COMPONENTS SHALL NOT BE CUT FOR PIPES, MEDICAL EQUIPMENT SCHEDULE CONN CONNECTION PKG PACKAGE 00 DUCTS,ETC. I NC CONT CONTINUOUS PL PLATE U F- mN KEY MED REQ'D REFEREE COORD COORDINATE PLCS PLACES U) d CRSI CONCERTE REINFORCING STEEL PLF POUNDS FORCE PER LINEAR FOOT LU • 8. THESE PLANS DO NOT INCLUDE NECESSARY COMPONENTS FOR SAFETY OF NOTE EQUIP ANCHORS DETAIL NOTES INSTITUTE PREFAB PREFABRICATED) > THE BUILDING OR EQUIPMENT DURING CONSTRUCTION. CONTRACTOR SHALL BE TOSHIBA REFERENCE DRAWINGS: Infinix SELECT(Prof.No. 150015249VLF) CTLJ CONTROL JOINT PRELIM PRELIMINARY RESPONSIBLE FOR ALL WORK RELATING FF CONSTRUCTION,ERECTION METHODS, CTR CENTER PSF POUNDS FORCE PER SQUARE FOOT Q BRACING,SHORING,RIGGING,GUYS,SCAFFOLDING,FORMWORK,AND OTHER O CAS-810A FLOOR SEE REFERENCE DETAILS FOR (e)'/."DIA DETAIL 1/S3 CTRD CENTERED PSI OPUNDS FORCE PER SQUARE INCH WORK REQUIRED TO SAFELY PERFORM THE WORK. 10 MOUNTED C-ARM BASE THROUGH BOLTS DETAIL 2/S3 BASE DIMENSIONS AND ANCHOR d PENNY(NAIL SIZE) PT PRESSURE TREATED r^ 0 PATTERN DBA DEFORMED BAR ANCHOR PVC POLYVINYL CHLORIDE vJ 9. STANDARD DETAILS AS SHOWN ON THE DRAWINGS ARE INTENDED TO BE CAT-880B PATIENT (6)3/."DIA DETAIL 1/S3 SEE REFERENCE DETAILS FOR DBL DOUBLE W W TYPICAL AND SHALL APPLY TO ALL SIMILAR SITUATIONS OCCURRING ON THE 1 t TABLE BASE THROUGH BOLTS DETAIL 2/S3 BASE DIMENSIONS AND ANCHOR DEG DEGREE Z PROJECT,WHETHER IN NOT THEY ARE KEYED IN EACH LOCATION.CONSULT PATTERN DIA DIAMETER RR RADIUSDAA REBAR DOWEL ADHESIVE ANCHOR Y J WITH ENGINEER FOR INTERPRETATION OF APPLICABILITY OF STANDARD DETAILS. (2)5/8"DIAx 2" DIAG DIAGONAL RECT RECTANGULAR,RECTANGLE LU 10.VISITS TO THE JOB SITE BY THE ENGINEER TO OBSERVE CONSTRUCTION O CABINET FLOOR EMBED HILT[KWIK SEE REFERENCE DETAILS FOR DIM DIMENSION REF REFERENCE J J DETAIL 4/S3 DL DEAD LOAD REINF REINFORCE,REINFORCING O BRACKET BOLTTZPER LENGTH AND ANCHOR SPACING DO DITTO d SHALL NOT IN ANY WAY MEAN THEY ARE GUARANTORS E THE CONTRACTOR'S BRACKET REQD REQUIRED L WORK,NOR RESPONSIBLE FOR COMPREHENSIVE OR SPECIAL INSPECTIONS, DTI DIRECT TENSION INDICATOR COORDINATION,SUPERVISION,NOR SAFETY AT THE JOB SITE. 10 GAGE x 8"x DWG DRAWING S I-BEAM '^ READ PLATE. ScCD SLIP CRITICAL(BOLTS) v, 00 CABINET BACKING ATTACH TO EACH EA EACH SCHED SCHEDULE 13 PLATE METAL STUD WITH DETAIL 5/S3 SEE REFERENCE DETAIL FOR EF EACH FACE SH SHEET EJ J& St Luke's 11"' STRUCTURAL STEEL (2)#10 STS,1' PLACEMENT AND LENGTH EXPANSION JOINT SIM SIMILAR FROM TOP AND EL ELEVATION SOG SLAB ON GRADE Health System 1. STRUCTURAL STEEL MATERIALS: BOTTOM ELEC ELECTRICAL SPCS SPACES A.EXCEPT WHERE OTHERWISE NOTED:ASTM A36 I ENGR ENGINEER SPEC(S) SPECIFICATION(S) r # 15-310 TOSHIBA REFERENCE DRAWINGS: Infinix ELITE (Proj.No. 150015249VLF1) EQ EQUAL SPECD SPECIFIED 2. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN CONFORMANCE EQ SP EQUALLY SPACED SPG SPACING PROJECT DATE WITH THE LATEST EDITION OF THE RISC MANUAL OF STEEL CONSTRUCTION. CAS-880(5-AXIS SEE REFERENCE DETAILS FOR EQUIP EQUIPMENT SQ SQUARE ROJEC.Mv.os Ts.os.sots 20 PORONTA)- (8UG DIA DETAIL 1/S3 BASE DIMENSIONS AND ANCHOR EW EACH WAY SSL SHORT SLOTTED HOLE 3. BOLTS: FRONTAL THROUGH BOLTS DETAIL 2/S3 PATTERN EXP JT EXPANSION JOINT SST STAINLESS STEEL ugawrr CHECKED A.EXCEPT WHERE OTHERWISE NOTED:ASTM A325-N(BRG TYPE)HIGH STRENGTH BOLTS CAT-880B PATIENT SEE REFERENCE DETAILS FOR EXST(E) EXISTING STD STANDARD (6UG BOLTS STIF STIFFENER tH wK B.BOLTS INDICATED AS MACHINE BOLTS(MB):ASTM A307 21 TABLE BASE THROUGH BOLTS DETAIL t/S3 BASE DIMENSIONS AND ANCHOR FAB FABRICATE,FABRICATION STL STEEL PATTERN FB FLAT BAR STRUCT STRUCTURAL REVISED 4. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AS REQUIRED TO MAINTAIN ATTACH TO METAL FD FLOOR DRAIN SYMM SYMMETRICAL PLUMBNESS AND STABILITY DURING ERECTION. LARGE MONITOR STUDS WITH(4)#10 SEE DETAIL FOR ANCHOR FDN FDN 5. ALL STRUCTURAL STEEL SHALL BE SHOP PRIMED WITH A RUST INHIBITIVE PRIMER UNLESS 22 MANAGER BACKING DETAIL 1/S1 PLATE STS(ONE AT EACH PATTERN FF FINISH FLOOR T8B TOP AND BOTTOM OTHERWISE NOTED.PRIMER PAINT SHALL BE HELD BACK 3-INCHES FROM ALL CONNECTIONS CORNER) FG FINISH GRADE TAS THREADED ANCHOR STUD TO BE FIELD WELDED.JOINTS SHALL BE FIELD PRIMED AFTER SUCCESSFUL COMPLETION FRP FIBERGLASS REINFORCED PLASTIC TOC TOP OF CONCRETE OF ALL TESTING AND INSPECTION. (2)5/8"DIA x 2" FT FEET,FOOT TOF TOP OF FOOTING 23 CABINET FLOOR EMBED HILTI KWIK SEE REFERENCE DETAILS FOR FTG FOOTING THK THICK BRACKET BOLT TZ PER DETAIL 4/S3 LENGTH AND ANCHOR SPACING FV FIELD VERIFY THRU THROUGH BRACKET TOM TOP OF MASONRY GA GAUGE,GAGE 10 GAGE x 8"x T.O. TOP S STRUCTURAL WELDING REQD PLATE. GLBV GLUE LAME ATEDTBEAM TRANSV TRANSVERSE 1. ALL WELDS SHALL BE PERFORMED BY CERTIFIED WELDERS AND SHALL CONFORM TO CABINET BACKING ATTACH TO EACH TOS TOP OF STEEL SEE REFERENCE DETAIL FOR TOW TOP OF WALL AWS D1.1.ALL WELDS SHALL BE PERFORMED WITH E70XX ELECTRODES OR EQUAL.ALL 24 PLATE METAL STUD W ITH DETAIL 5/S3 H.A.S. HEADED ANCHOR STUD SQUARE AND BEVELED GROOVED WELDS SHALL BE COMPLETE PENETRATION WELDS (2)#10 STS,1' PLACEMENT AND LENGTH HORIZ HORIZONTAL TYP TYPICAL (CJP)UNLESS OTHERWISE NOTED. FROMTOP AND HPT HIGH POINT UBC UNIFORM BUILDING CODE BOTTOM HSS HOLLOW STRUCTURAL SECTION UNIF UNIFORM,UNIFORMLY 2. WELDING PROCEDURE QUALIFICATIONS AND WELDER QUALIFICATIONS SHALL BE I HVAC HEATING,VENTILATION,AND UON UNLESS OTHERWISE NOTED SUBMITTED FOR REVIEW AND APPROVAL BY THE ENGINEER PRIOR TO STARTING THE WORK. AIR CONDITIONING 3. NON-DESTRUCTIVE TESTING OF WELDS SHALL BE PERFORMED IN ACCORDANCE WITH IBC INTERNATIONAL BUILDING CODE VERT VERTICAL SHEETTIREID INSIDE DIAMETER AWS D1.1 EXCEPT SECTION 6.6.5 SHALL BE REPLACED WITH THE FOLLOWING AT NO W WIDE FLANGE BEAM ADDITIONAL COST TO THE OWNER: I.F. INSIDE FACE WP WORKING POINT GENERAL IN INCH(ES) WS WATERSTOP STRUCTURAL "THE OWNER RESERVES THE RIGHT TO USE ANY NON-DESTRUCTIVE WELD TESTING WT WEIGHT METHOD,INCLUDING RADIOGRAPHIC TESTING,TO VERIFY THE SOUNDNESS AND QUALITY WWF WELDED WIRE FABRIC NOTES& OF WELDS. IN ADDITION,FREQUENCY OF WELD TESTING MAYBE INCREASED AT THE NOTES: ABBREVIATION ENGINEER'S DISCRETION WHERE POOR WELDING WORKMANSHIP IS ENCOUNTERED." FOR ABBREVIATIONS NOT LISTED,SEE GENERAL ABBREVIATIONS AND ASME Y14.38-"ABBREVIATIONS AND ACRONYMS FOR USE ON 4. ALL WELDS FOUND DEFECTIVE SHALL BE REPAIRED AND/OR REPLACED AND RETESTED DRAWINGS AND RELATED DOCUMENTS"AS DISTRIBUTED BY THE FOR ADEQUACY AT THE CONTRACTOR'S SOLE EXPENSE. AMERICAN SOCIETY OF MECHANICAL ENGINEERS(ASME). SHEET 5. CONTRACTOR SHALL UTILIZE NECESSARY WELD PROVISIONS AS READ TO PREVENT DAMAGE TO CONCRETE FROM FIELD WELD OPERATIONS INVOLVING EMBEDDED PLATES, ANGLES,AND OTHER MEMBERS. `�O.^1 ^ 428042_MV09_Sol.dgn 2015\06\04 4:05:21 PM r CONTROL ROOM o O ANCHOR BRACKETS ANGIO A CABINET BACKING (BY EQPT MFR), 51242 PLATE,FOR ADDTL 5 TOTAL 12 INFORMATION SEE 13 (E)W1610 ..-� EQUIPMENT ROOM E)W14x22 J _ H1241A x ( w W 20G �/ o TABLE BASE 21 M (3)L4x4xREQD ` EQPT MFR)SE 0 W 000 BELOW(TYP) `I 1 SEE 1 � n/ � DUAL PLANE LAB 1S'_11�'ts" \ _ s3.1 , ,•,•�•� � I m � H1241 _ 1 Q J o 6"DIA CORE DRILL, -T ! j Q . o•J 000 FIELD LOCATE. DO NOT (E)W16y.31 7"DIA CORE y•� t0 CORE DRILL THROUGH DRILL .�'�,.J-•"•••••.,,, / EW14x22 = Z a0cc STEEL BEAM BELOW �� O x-�p --1 i 1 �' f ly— O a f �y°\••• I 00�M 20 SEE I ��1 boo coo O CONTROL ROOM 1 j \ • TABLE BASE 11 (3)L4x4xREQD i 1 (BY EQPT MFR), BELOW(TYP) _ _ SEE U- 2 Q U) --,1 1 11 W14x2 w 1�1 � •r 1 f � WORK I tl Z 1............ POINT j 1 Ll.l 7"DIA CORE J DRILL 1 (E)W16%3A O k' 1 MCD 1 I 1 1' CD 1 1 j 00 ANCHOR BRACKETS I .I 1 cn (BY EQPT MFR)3 TOTAL '1 J` St Luke's I - �l Health System o 11 EQPT BASE\10 ' !1 ` ` I 1 # 15-310 / 1 (BY EQPT MFR W I 1 1 I EQUIPMENT CLOSE ( 422SEE5 POECT DATEWORK POINT H1242B 429042.MV.09 06.05.2 015 DRAWN CHECKED I LH WK STO E--".. 1 \� [ACOREDRILL (E)W16x31 1 _ — — '1 REVISED- 1 � H1241C a BE(3)L4x4xREQD 6"DIA CORE CABINET BACKING DRILL PLATE,FOR_ 1,LOW(TYP) 1 \..�,� _ _ _ INFORMATION 24 I I W ;� — — — �,_..�•••"••'• 3/16"x 36"SO BACKING O j 1 — — — — ,---J„-•" '1 PLATE,FOR ADDTL '1 INFORMATION 23 1 R22 10G 1 .1 30'0 aA NOTES: SHEET TIRE 1. FOR GENERAL STRUCTURAL NOTES SEE SHEET S0.1. 1 2. ALL DIMENSIONS TO EXISTING ELEMENTS ARE BASED ON ORIGINAL EQUIPMENT 1 '1 CONSTRUCTION DOCUMENTS AND SHALL BE FIELD VERIFIED BY THE SUPPORT 2 6 1 CONTRACTOR PRIOR TO CONSTRUCTION. PLANS 1 1 3. COORDINATE LOCATION DIMENSIONS FOR MEDICAL EQUIPMENT SUPPORT WITH O EXISTING METAL DECK WITH CONRETE TOPPING EQUIPMENT MANUFACTURER DRAWINGS AND ARCHITECTURAL PRIOR TO 1, FABRICATION AND INSTALLATION. 6A 7A N 4. SEE SHEET S0.1 FOR MEDICAL EQUIPMENT SCHEDULE WITH KEY NOTES OX SHEET 5. FIELD LOCATE ALL CORE DRILL FLOOR PENETRATIONS. DO NOT DRILL THROUGH FIRST FLOOR EQUIPMENT PLAN O STRUCTURAL FRAMING BELOW. -171 428042_MV09_S11.dgn 2015W6\04 4:27:09 PM --� NOTES: 1 1. FOR GENERAL STRUCTURAL NOTES SEE SHEET S0.1. 1 I 1 2. ALL DIMENSIONS TO EXISTING ELEMENTS ARE BASED ON ORIGINAL CONSTRUCTION DOCUMENTS AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO �....- E\N14x22 CONSTRUCTION. .—. 3. COORDINATE ALL LOCATION DIMENSIONS FOR MEDICAL IL d, EQUIPMENT SUPPORT WITH EQUIPMENT MANUFACTURER DRAWINGS AND ARCHITECTURAL PRIOR TO FABRICATION 10'4�4 AND INSTALLATION. T,-0" 4. CEILING MOUNTED EQUIPMENT RAILS(BY EQUIPMENT MANUFACTURER). COORDINATE LOCATION WITH EQUIPMENT DRAWINGS AND ARCHITECTURAL. (E)W18x35 - (E)W 14.22 S3.1 S3.1 10F --- rYP 1 — — --------- DUAL PLANE LAB 4 � �"- i ` W ���� 1 I! � - �•� CIA c� In ce) V.r x35 U L �!t _,"- W14x22I LU cD ID C6 --. .1 I LL 0.000 . I _ NOTE4__ 1' �� ` - - I _ !L '- - J rOm t - -. W to W1Ax22 m ai can I 1��. ' .11 OD o WORK- 1 V OON 1 POINT I LLI I 1 BELOW �� �� ,/ • tS -�°� 1 rn q 1 `J NOTE 4 - -' -- r DO �.��•-••-• Vp. 35 W II' ti'. rn (E)W 18x a - a I v J Ix co 1 I -1... d 1 — — 8" io �?7- I LU LLI Z --I J 2 z" �1 S3.1 P j a `-- 2 4 TYP 1 i '�^/ O xgD I -': E W14x22 I vJ co S3.1 53.1 1 N MC6 CHANNELS x REQD J���L'''''' St Luke's (TYP) I Heals system ANGIO LAB 'I # 15-310 N q I UJ� (E)W18x35 '1 H1242 I 1 'WORK I I PROJECT DATE 1 POINT `I d f-•�" i�BtLO - N _ - '1 I 428042.hN.09 06.05.2015 ..• DRAWN CHECKED _ _ LH WK _ _ I _ - - - REVISED MAX 111 I� MAX 1 (TMP)6 CHANNELS.REQD '1 I i 1 (E)W 18x35 TMP I ! r 2 53.1 1 I R22 1 SHEETTRLE 1 O CEILING 30 0" LEGEND MOUNTED $A LONGITUDINAL(UPPER)UNISTRUT P1001 EQUIPMENT --------- TRANSVERSE(LOWER)UNISTRUT P1001 PLAN .1 HANGER LOCATION,SEE DETAILS 2 AND 4 ON S3.1 N LATERAL BRACING LOCATION,SEE DETAIL 3 ON S3.1 SHEET ,1 ! O CEILING MOUNTED EQUIPMENT PLAN IE(2)MC6x15.3,SEE DETAIL 2 ON S3.1 (SECOND FLOOR FRAMING SHOWN) 1O EXISTING METAL DECK WITH CONCRETE TOPPING S 1- 2 6A �A 428042_MV09_S12.dgn 2015\06\04 5:59:42 PM EQUIPMENT BASE T,P OR FLOOR PLATE, SEE PLANS UNISTRUT CHANNEL STIFFENER, FOR ATTACHMENT TO P1000 UNISTRUT CORE DRILL, DOUBLE CHANNEL NEW OR EXST METAL SEE 2 STRUCTURE ABOVE, SIZE AND FOR DECK WITH CONCRETE SEE(@ BEAM,SEE PLAN 3 TOPPING P2485 CRADLE TYP LOCATION 3/4"DIA THREADED A36 ROD ij CUP 4"MIN G �OHb d% THREADED i�." .�i - SQUARE WASHER AND NUT 6"MAX DOUBLE NUT(TYP) '� r ROD °" "^ (TYP T&B AS SHOWN) W a. a ° L3x3x1/4xREQD T&B P3008 NUT _ o 4, ----- Z d . 3/8"x1"HEX HEAD 5 --- ----------'li------------ �sd rStP�Q NEW OR EXST WF CAP SCREW CORE DRILL HOLES _ i ----- Y7 BEAM (BOLT DIA+1/16) USE — CRADLE CLIP ASSEMBLY BASE TEMPLAPLATE EAS _______---!�!____________ CONNECTION AT SIM CENTERBOLTE 2" L4x4x3/8xREQD LONGITUDINAL HORIZONTAL LEG OF ANGLE MIN (UPPER)SUPPORT CONTINUOUS TYP UNISTRUT P1001 (WHERE OCCURS) WFBEAMBEYOND SECTION ------------ - -6— ---�----------- -- ----------- NOTES: TRANSVERSE I- (MAX) ►1 FINISHED CEILING, (LOWER)UNISTRUT COORD WITH TACK WELD L3x3x1/4xREQD 1. TABLE BASE OR FLOORPLATE PROVIDED BY EQUIPMENT MANUFACTURER. P1001 SUPPORT SECTION ARCHITECTURAL f! BACK TO PREVENT INSTALL PLATE LEVEL WITHIN 1/16"ACROSS SURFACE PLATE. COORDINATE DISPLACEMENT ORIENTATION WITH ARCHITECTURAL AND EQUIPMENT MANUFACTURER. SUBMIT FIELD VERIFIED LAYOUT DRAWING FOR APPROVAL PRIOR TO FABRICATION AND UNISTRUT CONNECTION —� INSTALLATION. TO BACK DOUBLE CHANNEL 2. SEE EQUIPMENT MANUFACTURER'S DRAWINGS FOR ADDITIONAL MOUNTING 3"=1'-0" ui Q HANNELS WITH j BEAM,SEE PLAN REQUIREMENTS. -INCH GAP TYP T&B �Z TYPICAL FLOOR PLATE MOUNTING M LU aD j 1/4"x3"SQ PLATE 8" S1.1 L.L WASHER T&B P100 DIAGONAL BRACE, J o SECTION A-A SECTION B-B NOTES 1/2"DIA BOLT WITH LONGITUDINAL 6"MIN J LaL �m0 U(UPPER)UNISTRUT P1737"U-SHAPE" SPRINGCHANNEL NUT AND 35°-55° P1001 SUPPORT CONNECTOR(TYP EA = Z ago�� MAIN BRG SUPPORT) — x SEE PLAN 1/2"DIA CHANNEL o--Cc Lo - CEILING NUT WITH SPRINGUNISTRUT m tU ccl j B I COORD BOLTED CONN NUT WITH SPRING NGEL O O o A WITH ARCH (TYP) --------- U � dCDN P1001 TRANSVERSE UNISTRUT �T I U j • N DOUBLE NUT T&B, SUPPORT,(LONGITUDINAL j SEE NOTE UNISTRUT SUPPORT SIMILAR) - ---- ------------ " SEE NOTE 1(TYP) O TO UNISTRUT FRAMING FINISHED CONTINUOUS //� ' CEILING,COORD WHERE OCCURS vJ 2" EXST METAL DECK WITH ARCH TRANSVERSE MIN i i WITH CONC TOPPING SECTION (LOWER)UNISTRUT W Z BRG P1001 SUPPORT Y J L4x4 - TYP UNISTRUT CONNECTION o NEW OR EXST 1/4"x2 1/2"x2 1/2" v 3"=1'-0" WF BEAM B , UNISTRUT P1822 — PLATE WASHER T&B � A / UNISTRUT P1000,"T' I— � BACK TO BACK FOR HANGER ROD i � UNISTRUT P1000 J co DOUBLE CHANNEL INFORMATION DIAGONAL BRACE, NOTE 4 BEAM,SEE PLAN SEEg NOTE 3 35°-55° UNIST1' 4 P1843RUT AIL St Luke's Health System PERP TO DECK FLUTES , r # 15-310 ' P1000"T"UNISTRUT SECTION A-A UNISTRUT CRADLE CLIP CHANNEL A EXST METAL DECK PROJECT DATE STIFFENER,NOTE 4 PLACE ANGLE AT WITH CONC TOPPING 428042.MV.09 06.05.2015 ASSEMBLY AT 18"MAX s• BOTTOM OF FILLET NOTE 4 VERT SPACING,MIN OF 2 L4x4x1/4x0'-4" PER STIFFENER 4 DRAWN CHECKED T LH WK x STRUCTURAL PLATE -- ----------- -------- OR UNISTRUT _ _ ' 3/4"DIA A36 THREADED UNISTRUT NOTE 2 RLviseD ROD x REQD(TYP) P1822 P1000 DIAGONAL BRACE,NOTE 3 METAL DECK \\\ UNISTRUT P1843, BOTTOM FLUTE NOTE 5 BEAM,SEE PLAN � A P1000 DIAGONAL •�• 351%55° BRACE,NOTE 3 TYPICAL CONNECTION AT WF BEAM PARALLEL TO DECK FLUTES NOTES: 1. METAL DECK AND CONCRETE TOPPING NOT SHOWN. NOTES: 2. BEAM SHALL BE INSTALLED LEVEL AND BEARING ON BOTTOM FLANGE OF SUPPORTING BEAM. SIMILAR CONDITION 1. COORDINATE LOCATION AND ELEVATION OF SUPPORT WITH SHALL ONLY BE USED WHEN SUPPORTING BEAMS ARE DIFFERENT DEPTHS. ARCHITECTURAL AND EQUIPMENT MANUFACTURER PRIOR TO INSTALLATION. 3. AT CONTRACTOR'S OPTION, INSTALLATION OF SINGLE NUT WITH TACK WELD TO PREVENT DISPLACEMENT MAY BE 2. HILTI S-MD 12-24 x 1 1/4 HWH 95 KWIK-PRO SELF DRILLING SCREWS. INSTALL USED IN LIEU OF DOUBLE NUT AT LOCATIONS WHERE CONFLICTS PREVENT USE OF DOUBLE NUT. PER MANUFACTURER'S INSTRUCTIONS. SHEETTITLE 4. ALL THREADS OF ROD COUPLER SHALL BE FULLY ENGAGED;TACK WELD IN PLACE AFTER COMPLETED INSTALLATION. 3. P1000 UNISTRUT BRACE SHALL NOT EXCEED 10'MAXIMUM LENGTH. 5. AT CONTRACTOR'S OPTION,INSTALLATION OF SINGLE NUT WITH TACK WELD TO PREVENT DISPLACEMENT MAY BE 4. 5/8"DIA x 3"MINIMUM EMBED HILTI KWIK BOLT-TZ. SPECIAL INSPECTION EQUIPMENT USED IN LIEU OF DOUBLE NUT AT LOCATIONS WHERE CONFLICTS PREVENT USE OF DOUBLE NUT. REQUIRED. SUPPORT 4. STIFFENER ASSEMBLY NOT REQUIRED FOR THREADED RODS WITH MAXIMUM CLEAR SPAN LENGTH LESS THAN 18". 5. TACK WELD HINGE AFTER FINAL EQUIPMENT ALIGNMENT. DETAILS DOUBLE CHANNEL EQUIPMENT SUPPORT LATERAL BRACE ANCHORAGE SHEET S1.2 428042_MV09_S31.dgn 2015\06\04 5:57:15 PM R W (EXST)W14x22 ti `r,�•� r5tp�p Ir cJi�w WORK POINT L2x2,TYP ----- ----------- x11.5 24"DIA CORE DRILL IN ' � i 5 C{ (EXST)METAL DECK W/ i i I i i W CONC TOPPING,CENTERED ' ' ' ' ON EQPT BASE 13 3/4"DIA BOLT CIRCLE a _! U - -'-m-- - •�-- - - I---- EQPT ID/. in 8"DIA HOLE,CENTERED ' ' \• ,/ io O O ON EQPT BASE i i i , GROUT FILL 3 1/2"MAX,TYP 0 �L BOLT 1 1/2"MIN FOR 3/4"BOLTS, A325N BOLTS W/ 1 3/4"MIN FOR 7/8"BOLTS,TYP (c j ' C8x11.5 ' ' w SHORT SLOTTED I 1 1/2"MIN AT COPED w � ------- -------- HORIZ HOLES IN BEAM FLANGE,TYP �N/ EQUIPMENT MFR)E -------------------------- ' ' BEAM,TYP LION Of � (BY EQUIP MFR) I 3/8"SHEAR 5/8"x 3'-6" PLATE,TYP 00 SQUARE EXST W14x22 PLATE I I M _- Q J ..................................... ......2 ih J LL Do Co o Z ELM ONE SIDED in 1/4 it 2 m�v CONDITION 1/4 -I PLAN — (TYP) Q IF GREATER I ��� U ~ dm04 THAN 3",USE w ONE SIDE STEEL BEAM OR LIJ � N CONN @ CHANNEL,TYP > EQPT BASE(BY r DEEPER BEAM 1 1/2" 1/4 EQPT MFR) 0�j MIN 1/4 TYP C Q (EXST)METAL DECK Oitu�8"DIA HOLE TWO SIDE CONN ONE SIDE CONN ''^^ V) W/CONC TOPPING I fGROUT " E DRILL LLI w j NOMINAL BEAM ROWS OF BOLT DIA, LENGTH OF DEPTH,INCHES BOLTS INCHES SHEAR PLATE Z J i 8-10 2 3/4" 6" W I J STRENGTH,SELF NOTES: J O LING,NON-SHRINK 1. NUMBER OF ROWS IS EQUAL TO NUMBER OF BOLTS CONNECTING SHEAR TAB FZ TYP 3/16 1@6 5/8"PLATE FILLPLATE TO BEAM. 'F^"1/4 x 7",TYP AT CORNERS V) 0CB(TYP) TYP 1/4 2. AT ONE-SIDED CONNECTIONS,EXTEND TOP OF SHEAR TAB PLATE FULL HEIGHT LOF BEAM AS SHOWN. ��1'-6" V-6" NEL BEYOND 3. (")DIMENSION SHALL BE 3"UNLESS OTHERWISE REQUIRED FOR PROPER AL St Luke S FABRICATION. 'I'J'rHealth System ( ) "DIA THROUGH BOLT 4. AT CONTRACTOR'S OPTION,OMIT BOLTS AND FIELD WELD INCOMING BEAM TO # 15-310 SECTION SHEAR TAB PLATE WITH 1/4"FILLET WELD PROJECT DATE 428042.MV.09 06.05.2015 r1 CAS 880 MOUNTING DETAIL 2 TYPICAL BEAM TO BEAM CONNECTION DRAWN CHECKED NTS LH WK REVISED SHEETTITLE EQUIPMENT SUPPORT DETAILS SHEET S-3.2 428042_MV09_S32.dgn 2015\06\04 4:04:15 PM LL=::_�j DIFFUSER, REGISTER & GRILLE SCHEDULE VENTILATION CALCULATIONS PLAN MODULE FINISH/ DAMPER MC 2012 FGI HEALTHCARE GUIDELINES CODE MFR MODEL SERVICE MATERIAL ACCESSORIES REMARKS 2014 REQ'D SIZE COLOR TYPE CEILING MIN REQ'D REQ'D DESIGN DESIGN DESIGN ZONE ROOM NAME ROOM• PEOPLE AREA HT SPADE TYPE MIN CA FTA— CDSTANDARD TOTAL OA 100% TOTAL ExN CFM GFM OA CFNI E_HCFM TITUS TDGA SUPPLY STEEL 24"x24" WHITE NONE NONE NECK SIZE SHALL MATCH RUNOUTS ON DRAWINGS, Rp Ra Vbz Ez voz ACI-1 ACW PRESS' EXH CFM CFM STANDARD CD-1 TITUS PSS-AA SUPPLY STEEL 24"x24" WHITE NONE NONE NECK SIZE SHALL MATCH RU WING$. NOUTS ON DRA 54V-11-13 ANGIO LAB HI242 6 605 93 CATH LAB --- --- 1600 L11`2tr --- COMPLIES STANDARD _-- --- l-7, --- I5 3 POS --- 1411 262 SG TITUS �5.F SUPPLY STEEL --- WN1TE NONE NONE MATCH FACE SIZE SHOLLN ON DRAWINGS. SAV-IIT4 EQUIPMENT H12425 0 40 9ID UTILITY 0 0 0 0B 0 0 0 __0 0 400 000MPLIESTITUS RETURN ALUMINUM --- A'ND'ARD NONE NONE MATCH FACE SIZE SHOWN ON DRAWINGS. _ $ O WHIT£ SAV-11T6 CONTROL 141242A 2 230 9ID OFFICE 0 0ID6 14 0B IT 0 0 --- ___ I50 rI ___ 150 45 -- COMPLIES o� 0 NOTES: IN i I.SUBJECT TO COMPLIANCE WITH REQUIREMENTS,PRODUCTS FROM THE FOLLOWING MANUFACTURERS ARE ACCEPTABLE ALTERNATIVES:CARNES,KRIEGER, SAV-11T6 CONTROL HI241B 2 230 9ID OFFICE 0 0ID6 14 0B IT 0 0 150 IT -- 150 45 --- COMPLIES M v o METAL AIRS,NAILOR,PRICE,TITUS t TUTTLE t BAILEY. W M� 2.CONTRACTOR SHALL VERIFY EXACT BUILDING CGNSTRUCTION t CEILING TYPES t PROVIDE CORRECT FRAMES FOR ALL AIR DIFFUSION PRODUCTS AS SAV-11T6 HALL H1464 0 215 9ID CORRIDOR 0 0ID6 Il 0B 21 0 0 --- --- 100 21 --- 100 30 --- COMPLIES REQUIRED. VERIFY ALL COLORS t FINISHES WITH ARCHITECT PRIOR TO SUBMITTAL. \G 3,SECURE AND/OR SUPPORT ALL DIFFUSERS,REGISTERS t GRILLES IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE STANDARDS FOR SEISMIC $Av-IIT� EQUIPMENT H1241A 0 150 9ID UTILITY 0 0 0 0.6 0 0 0 --- --- 0 0 --- I600 0 --- COMPLIES E B DESIGN. DUAL PLAN F 4.PROVIDE EXTENDED LINKAGE FROM HAND DAMPER TO A FLUSH CUP CONCEALED DAMPER REGULATOR IN ALL HARD CEILING LOCATIONS CHARD, SAV-1181 LAB NI24f 6 680 93 CATH LAB ___ _ ___ ___ 15 3 PO$ --- 1581 316 --- 1600 4Tl --- COMPLIES INACCESSIBLE CEILINGSJ. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR ALL CEILING TYPES. NOTES: 1.DESIGN MINIMUM OUTSIDE AIR(MIN CA)1$BASED ON 30%OUTDOOR AIR MINIMUM POSITION AT THE AIR HANDLER SAV SCHEDULE MECHANICAL LEGEND NO MODEL LOCATION DESIGN MINIMUM NORMAL CONNECTION RANGE HEATING COILB CFM CFM OPERATION SIZE(OCO GP-I(MAX) EWT LWT GPM WPD APD MBH LAT MANUFACTURER SYMBOL DESCRIPTION SYMBOL DESCRIPTION co o 11T2 NSVAl10M-ALOHN-P HI4T 620 420 VAR VOL 96T"OD 50-i000 140 IrT IID 5' 35" <12 <84 2(EX)NEW PHOENIX"THERIS" NEW TO EXISTING CONNECTION Q8 TEMPERATURE SENSOR yl 1113 HSVA214M-ALOHN-P HI242 3500 1600 VAR VOL 30"A5" 400-5000 140 I'll45 5' 35" 435161,0 3,4 NEW PHOENIX"THERIS" TYPICAL DEMOLITION ITEMS ® to ------------�11 PRESSURE SENSOR A �4 HSVAI08M-ALOHN-P W12425 400 0 VAR VOL TB8"OD 35-'100 NA NA NA NA NA NA N/A I,2(EX)PHOENIX"T7-IERI$" �r1 W H$vA108M-ALO ® z EXISTING SUPPLY DUCT(UP OR DOWN) �e FIRE/SMOKE DAMPER �1 F" 11T6 HN-P HI241BMI242A 500 VAR VOL '188"OD 35-100 140 11T I •` ID 5' 35" 12 80 2(EX)PHOENIX"THERIS" s.4 EXISTING RETURN DUCT CUP OR DOWN) -ei SPIN-IN FITTING WITH HAND DAMPER O IITT NSVA212M-ALOHN HI241A 1600 0 VAR VOL 24.13"x12.13" 180-3000 N/A N/A N/A N/A N/A N/A N/A I,2(EX)PHOENIX"THERIS" 04 ® z EXISTING EXHAUST DUCT(UP OR DOWN) II81 HSVA212M-ALOHN 1241 1800 1600 VAR VOL 24.13"x12.13" 180-3000 140 110 35 5' 35" 525 82 3,4 NEW PHOENIX"THERIS" ® El SUPPLY DUCT CUP OR DOWN) O NOTES: TYPICAL EXISTING DUCTWORK RETURN DUCT(UP OR DOWN) 'Z I.VALVE ONLY RELOCATED.REHEAT COIL NOT REQUIRED.DESIGN BASED ON PRIMARY AIR ENTERING TEMPERATURE OF 55 DEG F. 0 Elr. 2.EXISTING VALVES ARE VARIABLE VOLUME CAPABLE AND SHALL BE CALIBRATED FOR FLOWS BETWEEN 30%-l0%OF THE MAX RANGE AND FIXED TO CONSTANT CFM IN THE FIELD. ® EXISTING CEILING SUPPLY DIFFUSER Elt EXHAUST DUCT CUP OR DOWN) O 3.VALVE AND HEATING COILS ARE NEW. HEATING COIL SELECTION BASED ON PRIMARY AIR ENTERING TEMPERATURE OF 55 DEG F. COIL$ARE TO BE 2-ROW. NG CEILING RETURN GRILLE 'NM1'W` FLEXIBLE DUCT 4.NEW VALVE SHALL BE VARIABLE VOLUME AND$HALL BE CALIBRATED FOR FLOWS BETWEEN 30%-10%OF THE MAX RANGE AND FIXED TO CONSTANT CFM IN EXISTI Q THE FIELD. �•L•I 5.AIR PRESSURE DROP(APD)IS TO BE RATED AT DESIGN CF ® EXISTING CEILING EXHAUST GRILLE M. ^®-- CEILING SUPPLY DIFFUSER 6.RE-NEAT COIL$SHALL BE STANDARD SIZE FOR ASSOCIATED VALVE SIZE. EXISTING SIDE WALL GRILLE OR LOUVER �—y- CEILING RETURN GRILLE EXISTING COLD WATER PIPING ®—r CEILING EXHAUST GRILLE M MECHANICAL ABBREVIATIONS —__— EXISTING HOT WATER PIPING SIDE WALL GRILLE OR LOUVER Q ---III J COMcheck Software Version 4.0.0 SYMBOL MEANING SYMBOL MEANING —_ EXISTING HOT WATER RETURN PIPING T MECHANICAL EQUIPMENT(PLAN VIEW) N � --i 1 Mechanical Compliance Certificate AFF ABOVE FINISHED FLOOR IN WC INCHES OF WATER COLUMN OTHER TYPICAL EXISTING PIPING x MECHANICAL EQUIPMENT IDENTIFICATION � J AWJ AUTHORITY HAVING MAX MAXIMUM CO CLEAN OUT Q Qa W m JURISDICTION P-x PLUMBING FIXTURE IDENTIFICATION !V; w AP ACCESS PANEL MBH ONE THOUSAND BTU PER WICO I✓ WALL CLEAN OUT COLD WATER PIPING Q m O uNi�i o Section 1ZZ:Project Information HOUR - o a m o a Energy Code:iA ECC BLDG BUILDING MFR MANUFACTURER PIPE BREAK —160— Z LLI Z— W Project Thle:SLMV 2ND CATH IAB BUILD-OUT —___ HOT WATER PIPING(TEMPERED TEMP INDICATED) Z z m N ob e, BTU BRITISVN THERMAL UNIT MIN MINIMUM PIPE RISE —160•I!— W Z N CO N N Project Type:Alteration _____ HOT WATER RETURN PIPING(TEMPERED TEMP INDICATED) Lu LL*:M1Con PO EJSue: Qner/Agent: Micha lW isdomP E. CD CEILING DIFFUSER N/A NOT APPLICABLE c PIPE DROP WASTE PIPING 801 POLE LINE ROAD N/6ST0_ En,nalong no P.E.THAN FALLS,ID Engineering Inc --al-- PIPE TEE DROP VENT PIPING = 2272 arwa.,ay Ave CFM CUBIC FEET PER MINUTE NC NOISE CRITERIA - - - m Boise,ID 83706 CO CLEAN OUT NO. NUMBER - -N9—r— HUMIDIFIER$TEAM R Section 2:General Information PIPE END CAP 1 1 .L Dr—Zonatonttorweatneraataj. Twin Falls,nano CON! CONCRETE NT$ NOT TO SCALE FLOW ARROW ��HG—'— HUMIDIFIER CONDENSATE J LSE Luke'S ° climax zorK sd PRESSURE DROP OR CONY CONTINUATION PD DIFFERENCE #15-310 Section 3:Mechanical Systems List GATE VALVE —WM— HEATING WATER SUPPLY 0 COLRD COORDINATE QTY QUANTITY a Quant& System Tv s Des l tl --H6F-- BALL VALVE — —FWR— — HEATING WATER RETURN PROJECT DATE CW COLD WATER RA RETURN AIR PROJ PROD gA20.2g15 g Section 4:Requirements Checklist H CIRCUIT SETTER(2"AND SMALLER LINES) —VAC— MEDICAL VACUUM LINE D DRAINAGE REQ'D REQUIRED CHECKED DAWN r — BACKFLOW PREVENTION DEVICE —HA— MEDICAL AIR AR MG Section 5:Compliance Statement DEG F DEGREES FAHRENHEIT Fir. RETURN GRILLE can Hance sraremene Tna TWO WAY TCv p proposed meeM1anwalalleration project represented nursdaeu,rem„;wnsiuent vanena dmming puns, DIA DIAMETER —02— OXYGEN LINE RPM REVOLUTION$PER MINUTE REVISED:Q O spa canon s and other Calculations submitted with this panne epplioatwn.The proposed mechanical alteration,q,, has been deagned THREE WAY TCv NITROUS OXIDE # Descri lion Date Q xrree[the20091ECC,Chapter 8,requlramenh in COMaYeck Version d.0.0 and xcomply vnth the mantlatory nquirementc in the DN DOWN $CBE. SCHEMATIC � Requirerrents Checklist. i ® FLEXIBLE CONNECTION —CG2— CARBON DIOXIDE 3 Michael Wisdom P.E. _ � �y Z•�5 £A EXHAUST AIR SD SUPPLY DIFFUSER D Name Tale - - igoamra Data EG EXHAUST GRILLE STD STANDARD 17 OT 7HER105TAT OR TEMPERATURE SENSOR N NITROGEN E Section 6:Post Construction Compliance Statement E EXISTING TAB TEST,ADJUST t BALANCE m O Hvac rawrd arawingswtne ageaal us}almmn,syaam oapaga�«,gaimm5on inr«rratiop and parkshaneadlto roraaehegnipmant FIRE PROTECTION pr.dedVAQO to theamec FPG TCC TEMPERATURE CONTROL HUMIDIFIER SCHEDULE DRAWING INDEX CONTRACTOR CONTRACTOR z HVAC 08M documents ror all mechanical equipment and system provided le the q r by the mechanical mntraclor. 3 O Mitten HVAC balancing and operations report picvlded to the owner. FPM FEET PER MINUTE T-STA7 THERMOSTAT POWER PLANSTEAM SHEET NUMBER p The above post construc[gn requuerrents have been completed. CODE MFR MODEL CHAR CONSUMPTION LB$/HR REMARKS M0ID MECHANICAL COVER SWEET GA GAUGE TYP TYPICAL (AMP) t_ MIJ HVAC DEMOLITION PLANS 0 p Principal Mechanical Dacignm-Name signature Date v VENT H- DRIS7EEM vAPORMIST-14 208/3 38.9 IlID SEE NOTE$GAL GALLONS MI.2 HVAC REMODEL PLANS 5 Project Notes: H-2 DRISTEEM VAPORMIST-6 208/3 25ID 35ID SEE NOTES M2.1 HYDRONIC DEMOLITION t REMODEL PLANS m This projeqt isarenanu mprovement prgject vam rw change to e.uw be�la� W PLI PLUMBING REMODEL PLANS m «omodate the tenant lmprovementln the shelledspace. g rig enve lope the exlsgng none system has been extended to GPM GALLONS PER MINUTE W ASTE •OR APPRO a VIED EQUAL SHEETTITLE NW HOT WATER W/ WITH P2.1 MEDICAL GAS DEMOLITION t REMODEL PLANS MECHANICAL F NOTES: FP%I FIRE PROTECTION PLAN I.PROVIDE WITH MODULATING CONTROL AND LIMIT ADJUSTMENT 0 2.COMPLETE PACKAGE WITH CABINET WITH FRONT DISPLAY AND CONTROL COVER PANEL. 3.FURNISH WITH SPACE HUMIDISTAT FOR MODULATING CONTROL,WITH DUCT SHEET HIGH LIMIT TO PREVENT CONDENSATION IN THE DUCT,AIR FLOW SWITCH, 10-90%AWR-POINT RANGE,AND ULTRA-SORB LV STEAM DISPERSION [ ASSEMBLY FOR DUCT MOUNTING TO MATCH DUCT SIZE. DISTRIBUTOR DISPERSION INLET TO BE HOSE TYPE AND CONNECTED PER N MANUFACTURER'S REQUIREMENT$. SHEET in in M0.0 a t a z B 7xn w 9x9 C GENERAL NOTES •,. 50 gg m xar� x Igo CrM Ibxb CD ® 5 xb CD eav bxb CD T5- "60 Gfi'I A. ALL WORK WITHIN CONTRACTOR'S SCOPE SHALL COMPLY 0 me bx6 CD g"m I I bxb GD 5 14 I "::', 6"e WITH ALL APPLICABLE STATE a LOCAL CODES 4 ALL 100 Cep REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. �� 13 iwi CONTRACTOR gx eav eav Sx CD b 20x• 22" x 1 22"• I�v12 B OR GI IINALL CONDITIONN ALLL EQUIPMENT NOTED TO MAINTAIN IN S 4 loxl e 9 � rc7■"o Iru Imo-.--rr b"ol I 150 CFM T"o lei RELOCATED. ALL EQUIPMENT BEING RELOCATED TO BE � e �1PN EN ryr�� CLEANED PRIOR TO REINSTALLATION. �• C. ALL DEMOLISHED EQUIPMENT THAT IS NOT SHOWN TO BE I 6x6 CD T- e^�@, 6 e - - - -� 9,vI C' lo" 1 ,ro 2050 I I eav , ,I' bTg CFM 1 REUSED IS TO BE TURNED OVER TO OWNER'S STOCK OR BE DISPOSED OF PER OWNER'S DIRECTION. p L NCO 100 c 1. �c 4 \ / xl L177 LZ13 !1� 0// �I1 15 I 1 j \ 9x9 CD T"OJ I �j Iv'� xl0 10x1 , D. CONTRACTOR TO IMPAIR AND PATCH BACK ANY HOLES IN 4 �. � r 1 i 1 8xl III •H 5 I L 110 GFl-I i i ----- -- - u_ - _ - _ ,o INSTALLATION ALLLS�ON OF VE IMEC 4ANICAL ITEMS LIW.THAT RESULT��DEMOLITION OR s�� M,o � I II 6av 3 1 11 14x12 DUG •- y• S'm " • ^B• l T E. MECHANICAL ITEMS BEING DEMOLISHED ON THE HVAC I 8"e a I 1 OPEN TO 1!' 9" S 1 1 xlo-{I � a na bxb CD DEMOLITION PLAN WILL BE SHOWN A8 A DARK DASHED 14x14 I -- me \� SPACE ,,y _ bxb CD 100 CFM e'°'v O ^ LINETYPE AND UNLESS OTHERWISE NOTED ARE TO BE CFM) I r;}Y� �' eav 100 CFNI 8"0 r'1 1 1 9x9 CD \A� • i606 �� x REMOVED. I I I 9x9 G 1"J3o CR"I aw 1 9x9 GDr- 11e6 - 6x6 CD 1 mlzatl 12 12 CD GD 9"P DUCT �( ISO CFM e e •> 100 3 Cfa'I F. VERIFY EQUIPMENT REQUIREMENTS a COORmINATE WITH ALL 'J--14x12 1 1 I 0 CFM Im OPEN TO OTHER TRADES AS NEEDED TO ENSURE THAT SERVICE< 1 1 1 Ioxl SPACE a 0x12 — OTHER REQUIRED CLEARANCES ARE MAINTAINED. pp (200� 6 9"• 50 CFM 150 CFM • G. SEAL ALL PENETRATIONS OF FIRE-RATED A65EMBLIES WITH 6 g - 5„ U.L.APPROVED FIRE-RATED SYSTEM. REFER TO g ARCHITECTURAL I '+,}t�4^i, I � T• uar �G 9 ,�f�t � I 9"♦ 1 1 111C ;\\ 9�9 CLt 9x9 CD 120 5 rr�� B eau ' 2 10x12-�1 � ��\ I 9x9 CD 2 CFM 200 CFM L 5 20 CFM 9 SAV 1be s� 1 2 - 24x12 SSR 5 - ,"• 1 1600cFMr - 40x16 FO 2, KEY NOTES �- I 4x16 ` Q ll I — �frj4 24x16 FO 6"q I. EXISTING SAV Iri'I TO BE REMOVED AND RELOCATED. _ I REMOVE EXISTING SUPPLY DUCTWORK UPSTREAM TO THE I SUPPLY MAIN AND ALL SUPPLY DUCTWORK DOWNSTREAM OF /�\a M V/ 9 5 24x16 b"• SAV AND THE EXISTING SUPPLY GRILLE. THE ASSOCIATED O (Typ_ -� - SENSOR TO BE REMOVED AND RELOCATED WITH SAV. FOR V IJ 47 S 18x14 F DNJ RELOCATION REFER TO THE HVAC SUPPLY PLAN ON SHEET MI2. FIELD VERIFY AND COORDINATE WITH EXISTING •,�'_"'�_z 1 �'v 28x14 FO Tn I107 14,0 84v _ CONDITIONS. M wI 5 Ibe a4V I 2. REMOVE THE EXISTING 8Av RELATED SUPPLY DUCTWORK O SAV UPSTREAM TO THE SUPPLY MAIN AND ALL EXISTING SUPPLY 22x16DUCTWORK DOWN OF SAV WITH RELATED CEILING DIFFUSERS. cl REMOVE THE ASSOCIATED SEN° R FOR SAV. FIELD VERIFY J • AND COORDINATE WITH EXISTING CONDITIONS. ' _ N 3. REMOVE THE EXISTING SAV RELATED SUPPLY DUCTWORK CD 12 0 9 g USTREAM �■^�r� 6 DUCTWORK DOWNSTREAM OF SAVTAND RELATED IRE/SMOKE M DAMPER IN DUCT. FIELD VERIFY AND COORDINATE WITH W ` 1 OTHER TRADES AS REQUIRED WHEN REMOVING FIRE/SMOKE Q DAMPER REMOVE RELATED SENSORS. FIELD VERIFY AND COORDINATE WITH EXISTING CONDITIONS. J - I 1 4. MAINTAIN EXISTING SUPPLY CEILING DIFFUSER AND teELATED 2 F- w SU LT AS RECAARED IN HALLWAY FOR RECONNECTION. LJJ AND COORDINATE WITH EXISTING. REFER TO FIELD VERIFY J " THE HVAC SUPPLY PLAN ON SHEET MI2 FOR FECONNEGTION. [Q, LLCJ N 3 S. REMOVE THE EXISTING FIRE/SMOKE DAMPER FROM THE EXISTING DUCTWORK. MAINTAIN AND RECONNECT DUCTWORK O m o N 1 LEVEL 1- HVAC SUPPLY DEMOLITION PLAN A5 REQUIRED. FIELD VERIFY AND COORDINATE WITH OTHER 12 r A o TRADES A5 REQUIRED. 7 Z Z a 6. REMOVE EXISTING SUPPLY DUCT MAIN AND MAINTAIN EXISTING N J = $o 0 W W N N N SUPPLY DUCT RUN-OUT TO EXISTING SAV FFQQRR RECONNECTION. \ REFER TO THE HVAC SUPPLY PLAN ON SWEET MI2 FOR /C J �iu EXISTING CONDITIONS. J �� ¢ / REVISED=NDIORK. FIELD VERIFY AND COORDINATE WITH G 0- 12x24RG Bxb 8xB ���� T. REMOVE EXISTING SUPPLY CEILING DIFFUSER AND SUPPLY � 100 CFM r^N xa °�', DUCT AS REQUIRED. REMAINING SUPPLY DUCT TO BE V' 20xIB CAPPED OR MAINTAIN FOR RECONNECTION. FOR 12x24 RECONNECTION REFER TO HVAC PLAN ON SHEET MI2. m f axe 150 Ik�L s S. NOT USED. •I St Ldws t �I 9. REMOVE EXISTING RETURN AIR GRILLE OR SIDEWALL GRILLE 1 r#15-310 o � 1 F / gxb RELATED RETURN DUCT AS REQUIRED. REMAINING RETURN DUCT TO BE MAINTAINED FOR RECONNECTION. FOR 1 MI2. FIELD VERIFY AND COORDINATE WITH EXISTING a RECONNECTION REFER TO THE HVAC PETURN PLAN ON SHEET PROJECT DATE o 12x24RG �— CONDITIONS 15008 05-20-2015 r I 10 9 I 12 24R DRAWN CHECKED 12xG xb I 1®. REMOVE THE EXISTING FIRE/SMOKE DAMPER WITH RETURN r 24x24R3 / OCFM- 'rl DUCT DEMOLITION. FIELD VERIFY AND COORDINATE WITHAS MG 1 900 CFM - - 11 OTHER TRADES AS REQUIRED FOR RELATED WORK WITH' 1 T • i 1 FIRE/SMOKE DAMPER REMOVAL. REVISED: S 1 , 1D �11 ox18 # II. REMOVE EXISTING RETURN DUCT AND CAP AT BRANCH MAIN. I,W-10xb - REFER TO THE HVAC RETURN PLAN ON SHEET MI2. FIELD # H Deta -' `- 1J. '� 20x10 --J 1 1 VERIFY AND COORDINATE WITH EXISTING CONDITIONS. 1 _ I�bxl6 �- 12. EXISTING RETURN GRILLE TO BE RELOCATED REFER TO THE C1 10 HVAC RETURN PLAN ON SHEET MI2. �- 18x14 RETURN 10 12x24RG DUCT OPEN 300CFM 13, EXISTING SECTION OF SUPPLY DUCT RUN-OUT FROM SUPPLY • TO SPACE �I 12xS MAIN TO BE REMOVED AS REQUIRED. CAP AND SEAL REMAIN I 10 SUPPLY DUCT AT SUPPLY MAIN. MAINTAIN THE REMAIN N 1 11 190o CFM SUPPLY DUCT RAN-OUT TO THE EXISTING 5Av FOR z ' Iyf 1 g 5AA29/a RECONNECTION. REFER TO THE HVAC SUPPLY PLAN ON SHEET M12 FOR REVISED DUCTWORK. FIELD VERIFY AND a x20 COORDINATE WITH EXISTING CONDITIONS. 12x24R2 xb 0 24x1H 120 I6xi4 KEYPLAN SHEET TITLE = r� ,. 12 24x8 9 24x24r'u HVAC 116lD0GFM a DEMOLITION 24x14 SHEET CCNTINUOIUS EXISTING TENANT > ' LS G 4 1 _ / SPACE TO REMAIN SHEET g 2 LEVEL 1- HVAC RETURN DEMOLITION PLAN n 1 M1.1 1/8"=1'-0" AREA OF WORK ,rl 1 1 ■ 1 ¢ z .24! �a �,..___ 0 KEY NOTES GENERAL NOTES 120GR-I 10x10 I. CONNECT NEW MEDIUM PRESSURE SUPPLY DUCT TO EXISTING A. ALL WORK WITHIN CONTRACTOR'S SCOPE SHALL COMPLY ® MEDIUM PRESSURE SUPPLY MAIN. FIELD VERIFY AND WITH ALL APPLICABLE STATE a LOCAL CODES a ALL 8 12x24RG x6 8x '"`^ COORDINATE WITH NEW AND EXISTING CONDITIONS. REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 100 CFM - O 20xi8 2. PROVIDE A NEW MEDIUM PRESSURE SUPPLY DUCT TAKE-OFF B. MECHANICAL ITEMS BEING DEMOLISHED ON THE HVAC 12x24 FROM NEW SUPPLY MAIN AND RECONNECT EXISTING MEDIUM DEMOLITION PLAN WILL BE SHOWN AS A DARK DASHED PRESSURE SUPPLY DUCT TO EXISTING SAV. FIELD VERIFY AND LINETYPE AND UNLESS OTHERWISE NOTED ARE TO BE Sx8 _ 50 - COORDINATE WITH NEW AND EXISTING CONDITIONS. REMOVED. I' 3. CONNECT NEW MEDIUM PRESSURE SUPPLY DUCT TO EXISTING C. CONTRACTOR SHALL CARE FOR STORE,AND MAINTAIN IN 1 ®Sxb I MEDIUM PRESSURE SUPPLY DUCT RUN-OUT TO EXISTING SAV. ORIGINAL CONDITION ALL EQUIPMENT NOTED TO BE 24x 1 I-a FIELD VERIFY AND COORDINATE WITH EXISTING. RELOCATED. ALL EQUIPMENT BEING RELOCATED TO BE L woo 24x12 1 40 RG 4. CONNECT NEW LOW PRESSURE SUPPLY DUCT TO EXISTING CLEANED PRIOR TO REINSTALLATION. 1 O am CFM IRKSUPPLY DUCT. FIELD VERIFY AND COORDINATE WITH NEW AND D. ALL DEMOLISHED EQUIPMENT THAT IS NOT SHOWN TO BE i s CO 1 15 ® EXISTING CONDITIONS. REUSED IS TO BE TURNED OVER TO OWNER'S STOCK OR BE A M N DISPOSED OF PER OWNER'S DIRECTION. v I 14 S. RELOCATED SAV,BALANCE TO VALUES SHOLLN IN SAV N SCHEDULE ON SHEET M2.1. E. CONTRACTOR TO REPAIR AND PATCH BACK ANY HOLES IN V\G WALLS ABOVE CEILING THAT RESULT FROM DEMOLITION OR 1 ® 15 6. NEW SAV BALANCE TO VALUES SHOWN IN SAV SCHEDULE ON INSTALLATION OF MECHANICAL ITEMS. V,4xl 0 16x14 0x0 SHEET M2.1. 111 14x12 - F, ON THE HVAC REMODEL PLAN T4B EXISTING HVAC WILL BE 2 xI2 RG 12x8 ` \11. PROVIDE NEW FIRE/SMOKE DAMPER SHOWN IN A LIGHTER LINETYPE FOR CLARITY AND THE NEW 30'J4 13 HVAC WILL BE SHOWN AS A DARK LINE. S. EXISTING SAv BALANCE TO VALUES SHOWN IN SAV SCHEDULE 20x14 ON SHEET M2.1. G. PROVIDE I"THICK ACOUSTICAL LINING ON ALL SUPPLY 4 d B 19 RETURN AIR DUCT MAINS WITHIN 15'-0"OF ALL EQUIPMENT 12x24RG S. PROVIDE NEW SENSOR AND CONNECT TO RELOCATED SAV,OR CONTAINING ROTATING COMPONENTS(FANS,COMPRESSORS, 19 -/ 300CFM EXISTING SAV OR NEW SAV. FIELD VERIFY AND COORDINATE ETC.). 12x8 15 WITH NEW AND EXISTING CONDITIONS. ,pl H. PROVIDE SEISMIC RESTRAINTS FOR ALL EQUIPMENT, 54,24 10. EXISTING SUPPLY CEILING DIFFUSER BALANCE TO CFM SHOWN DUCTWORK 4 PIPING AS RECOMMENDED IN THE LATEST .epi 11 1 1 13 ON PLAN. EDITION OF SMACNA"SEISMIC RESTRAINT MANUAL q+ �w 1 Q GUIDELINES FOR MECHANICAL EQUIPMENT." CONSULT LOCAL kkk 11. NEW SUPPLY CEILING DIFFUSER BALANCE TO CFM SHOWN ON CODES FOR THE SEISMIC RATING OF THE BUILDING SITE. _ 1 2Sx20 x6 ® PLAN. j•. / 24x14 12x24RG 1. VERIFY EQUIPMENT REQUIREMENTS a COORDINATE WITH ALL E- 2 15 1 15 U 20 CFM D. NEW SUPPLY CEILING GRILLE BALANCE TO CFM SHOWN ON OTHER TRADES AS NEEDED TO ENSURE THAT SERVICE a °~ 24x24 RG 14x12 xBBxl 1 Bxlm lT�' PLAN. OTHER REQUIRED CLEARANCES ARE MAINTAINED. O 13. CONNECT NEW RETURN DUCT TO EXISTING RETURN DUCT. J. SEAL ALL PENETRATIONS OF FIRE-RATED ASSEMBLIES WITH 6. I� 15 1 I VERIFY AND COORDINATE WITH EXISTING AND NEW CONDITIONS. UL.APPROVED FIRE-RATED SYSTEM. REFER TO ISxl2 RG 15 ARCHITECTURAL DRAWINGS. 24x18 12x12 9 300 ° 14. RELOCATED RETURN AIR GRILLE,BALANCE TO CFM SHOWN ON j.�.1�Z PLAN. K. DUCTWORK SIZES SHOWN ON DRAWINGS ARE NET FREE AREA 24x12 0 DIMENSIONS. IT 16 THE CONTRACTOR'S RESPONSIBILITY TO YEA 2 0 15. NEW RETURN AIR GRILLE BALANCE TO CFM SHOWN ON PLAN. ACCOUNT FOR ANY INSULATION OR LINING AS REQUIRED BY W� 1 r 24x12 la's S 16. SUPPLY DUCT RISE. VERIFY AND COORDINATE WITH SPECIFICATIONS.EXISTING O 24x14 1 �� CONDITIONS. L. PROVIDE SINGLE-THICKNESS TURNING VANES IN ALL Q w 1 am CONTINUOUS _ LOW-PRESSURE MITERED W-DEGREE ELBOWS.NO J LSRG-4 n. SUPPLY DUCT DROP. VERIFY AND COORDINATE WITH EXISTING BULLHEAD TEES ALLOWED. _ I x / CONDITIONS. M. PAINT ALL VISIBLE DUCTWORK BEHIND GRILLES a REGISTERS M 1 yy� 18. DUCT HUMIDIFIER INSERTION ASSEMBLY. FLAT BLACK W IS, COORDINATE EXACT PLACEMENT OF DUCTWORK W/ N. MECHANICAL CONTRACTOR SHALL PROVIDE ONE m STRUCTURAL TIE RODS 4 FRAMING. PRE-MANUFACTURED DUCT ACCESS DOOR FOR EACH COMBINATION FIRE/SMOKE DAMPER SMOKE DAMPER OR LEVEL 1- HVAC RETURN PLAN 20.HUMIDISTAT CONTROLLING HUMIDIFIER IN HOUSEKEEPING 1462. SMOKE DETECTOR IN DUCT SYSTEM. MECHANICAL J CONTRACTOR SHALL PROVIDE ONE PRE-MANUFACTURED 21. REBALANCE EXISTING SAv TO NEW DESIGN CFM SHOWN. HINGED,METAL,KEY LOCK ACCESS DOOR IN CEILING OR = W WALL WHEN DUCT 15 LOCATED ABOVE HARD OR 22. DUCT HUMIDITY HIGH LIMIT. INACCESSIBLE CEILING. COORDINATE WITH GENERAL B W CONTRACTOR FOR LOCATION 4 SIZE OF CEILING ACCESS Q w m N DOOR REFER TO DIV.B SPEC.FOR ADDITIONAL INFO. ' + Q o O. PROVIDE FLUSH CUP CONCEALED OPERATORS ON ALL HAND `J O a / 8 e w O 1 - 150 9 0 GAD x6 GD ® x g DAMPERS LOCATED ABOVE HARD OR INACCESSIBLE T CR.1 " CEILINGS. L!J o v g,p - 14x12 6" Z ai j ® l0 C Ina 6x6 GD Im 8"e 6x6 CD P. FLEXIBLE DUCT RUN-OUTS ARE LIMITED TO V-0"MAXIMUM 1� "p SAv 6 6 CD N J h w 100 CFM 2 rv.I Bn 80 CFM 3 6"e Iw1 LENGTH. > LLI 2 M tS N N xa° Fl 4 A H 4 I nYJ Imm 16x12 Q. VERIFY FINAL LOCATION OF DIFFUSERS,REGISTERS a GRILLES J 1 m a w = 2 f4.1 S g"o 11TT eav 4 9x CD 3 20"p 22' a• 22"e s4v WITH ARCHITECTURAL REFLECTED CEILING PLANS 4 a \ n,e 100 CFM x ELECTRICAL LIGHTING LAYOUT. � 2 T" / „p Ib 6"0 150 GfM �'J/^1 m �r 1 10x1 " - S Tx 20"e S 9 T„ 6,g 4M T'e 12"e R ALL CEILING DIFFUSERS SHALL BE 4-WAY THROW UNLESS VJ 6x6 Cl �12"p 8 1 ( II6] 1'o NOTED OTHERWISE ON PLANS. 100 ._ 9x9 CD 9x9 G 6"m 641 � eav '' 6x6 CD 12x12 ,n 14" „p 120 CFM 200 x I e4v eav eav 5p® l5 CFM S. VERIFY FINAL LOCATION OF T-STATS,HUMIDISTATS,AND C SENSORS WITH GENERAL CONTRACTOR PRIOR TO �! St Lulus CROW D T"p xl0 Iles ° x10 lsas Imxl 6„o T"m I INSTALLATION. i lie CFM p I S." - -- - - - - - -- �IIF#15-310 _ 3 x s I , bx6 CD S S PROJECT DATE 6 6 GD 10m CR'1 v a 15008 062P2015 F 1 20' • " eav 10m CRI 8"m 8"e Iesa x IS 1 ® 9"0 xb CD 1N� 61�a-� [• h ,��7p a , no& 6x6 CD - DRAWN CHECKED o I _ 9 44 :9x9 CD 60 i 100� 12 12 CD, ,,9 II ' I II ISO GFM 12"e e" e° 5oo CFM AS NIG TL 6 109x12a x9 915x09 CGIS REVISED x r ., „ 9CD : p • xp 18x12 4 II 150 CF'1 B„ ('- # Deem Don Date J 9 II 10. x9 G� 19 _ A 5 �np I 9 -WAY) 18I; `I 30x18 „p 1112 20 _ g g 9x9 GD S N ,„ 1 12x12 gxp 1 9x9 CD 2 CFM 200 CFM 9 my ery eQ ®6 4 1 S 11ae L �^ II 22 1 1 11 I, 120 GFM ! o—� Ilse 40x16 FO � 14x16 2' ' II 10"m 9x CD 1 11 b 10" , 40x14 FO 24,A 16„ o 2-WAY) 1 Q - g 1 2"e 2&x14 FO 1 - 0 10x10 CD-1 ® 600 CF'T 24x16 300 CFM 1IBxl4 FO fTYP.OF -� 1 _ (3-WAY) S e4v 12 26x14 F DN KEYPLAN SHEET TITLE m IIR - a 1 14 p 9 r ns, 1 21 400 cFrl - Ib amGFM HVAC 22x16 v Iee 21 V ' 241 _ I amGFM REMODEL 0 I A N EXISTING TENANT PLANS F I - _ 24 e g s SPACE TO REMAIN > L _ 1 SHEET an 21 we CFM _ 1 AREA OF WORK 2 LEVEL 1- HVAC SUPPLY PLAN M2.1 1/8"=1'-0' GENERAL NOTES �a A. ALL WORK WITHIN CONTRACTOR'S SCOPE SHALL COMPLY WITH ALL APPLICABLE STATE 4 LOCAL CODES 4 ALL REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. B. ITEMS BEING DEMOLISHED ON TE HYDRONIC DEMOLITION IV2 pa ®I�l'__ Aa PLAN WILL BE SHOWN AS A DARK DASHED LINETYPE AND Mr UNLESS OTHERWISE NOTED ARE TO BE REMOVED. C. CONTRACTOR SHALL CARE FOR STORE,AND MAINTAIN IN ORIGINAL CONDITION ALL EQUIPMENT NOTED TO BE H 4 ,p p' p RELOCATED. ALL EQUIPMENT BEING RELOCATED TO BE CLEANED PRIOR TO R=INSTALLATION. �0 L h00 11 -v / _ 6v I" SFr+ aev D. ALL DEMOLISHED EQUIPMENT THAT IS NOT SHOWN TO BE 1 1 �� IITS ;1 B44 i; IP19 d N O J 1 I T 9 / nee « I DISPOSED O'PER OWNER'S DIRECTION. REUSED 15 TO BE TURNED OVER TO OWNERS STOCK OR BE DISPOSED E. CONTRACTOR TO REPAIR AND PATCH BACK ANY HOLES IN WALLS ABOVE CEILING THAT RESULT FROM DEMOLITION OR INSTALLATION OF MECHANICAL ITEMS. t 1 1 &Av 1 I 2 I ~°dv I 1 II�T '"—� A I � 5 \ F. ON THE HYDRONIC REMODEL PLAN THE EXISTING EQUIPMENT IIeI �11 ® " ' 118 �II f AND PIPING WILL BE SHOWN IN A LIGHTER LINETYPE FOR m ® CLARITY AND THE NEW EQUIPMENT AND HYDRONIC WILL BE SHOWN AS A DARK LINE. G. PROVIDE SEISMIC RESTRAINTS FOR ALL EQUIPMENT<PIPING w AS RECOMMENDED IN THE LATEST EDITION O=SMACNA"SEISMIC "SEISMIC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL EQUIPMENT." CONSULT LOCAL CODES FOR THE SEISMIC I HUMIDIFICATION RATING OF THE BUILDING 51TE. I STEAM LINE fl A�W O H VERIFY OTHER TRADES AS NEEDED TO ENSURE TTS A WATNATE WITH ERVICE ALL OTHER REQUIRED CLEARANCES ARE MAINTAINED. 12 '•}"_;' I �n'4, In I. HEAL ALL PENETRATIONS OF FIRE-RATED ASSEMBLIES WITH A 1 f Im UL.APPROVED FIRE-RATED SYSTEM, REFER TO W ARCHITECTURAL DRAWINGS. HUMIDIFICATION c„ 1113 ►�1 EDO � ` _ _- 2 ®' — CONDEN5ATE LINE _ 2; O as 6 j• \ V I 2r'" HWR NOTE: i, \ N 1 2v''„ .. WWR Q)�. I��„ I 1 EXACT ROUTE FOR Lr S 00 oa STEAM 4 CONDENSATE ��" bo .,..�z PIPING TO BE y.�W�1�� I=" COORDINATED D SITE r KEY NOTES Oj � wi EXISTING CONDITIONS. - ��� o i •,r NEW WORK TO MAINTAIN �` -'1 a II14 '.I 1 PIPING SLOPES. �,1 I I. EXISTING SAV WITH RE-HEAT COIL TO BE REMOVED AND p I ' RELOCATED. REMOVE EXISTING HYDRO, EATING SUPPLY J AND EATING RETURN LINES AS REQUIRED. REMAINING Q _ 0 HEATING RETURN LINES ARE TO BE HYDRONIC HEATING ACAPPED OR MA NTAIED FOR RECONNECTION, m 1 © © REFER TO THE HYDRONIC REMODEL PLAN ON THIS SWEET, M 1 1 o m FIELD VERIFY W AND COORDINATE WITH EXISTING AND NEW CONDITIONS_ Q 2. REMOVE EXISTING SAV WITH RE-HEAT COILS. REMOVE J 1 — EXISTING HYDRONIC HEATING SUPPLY AND HEATING RETURN 1 I I-'� LINES AS REQUIRED. REMAINING HYDRONIC HEATING SUPPLY T M F AND HEATING RETURN LINES ARE TO BE EITHER CAPPED, Z REFER TO THE HYDRONIC REMODEL PLAN ON THIS SHEET W L FOR REVISED HYDRONIC PIPING. FIELD VERIFY AND Q W m COORDINATE WITH EXISTING AND NEW CONDITIONS. S' a 3. RELOCATED SAV. REVISE EXISTING HYDRONIC HEATING m m N 1 LEVEL 1— HYDRONIC DEMOLITION PLAN 2 LEVEL 1— HYDRONIC REMODEL PLAN SUPPLY AND HEATING RETURN LINES AS REQUIRED AND p r RECONNECT SAV RE-HEAT COIL,SEE HOT WATER WEATING o v r o M2.2 = M2.2 1113"=1'-0" COIL PIPING DETAIL A/2.I. BALANCE VALUES SHOWN IN SAV Z Z z v r SCHEDULE ON SHEET M2AV .1. N _I W �N TINN 3"FLANGE CONNECTION 4. NEW SAV. REVISE EXISTING HYDRONIC HEATING SUPPLY AND id PITCH SUPPLY FADER HEATING RETURN LINES AS REQUIRED AND CONNECT TO NEW SAV -HEAT COIL,SEE NOT WATER EATING COIL PIPING a CL DISPERSION TUBES DETAIL AR.I. BALANCE TO VALUES SHOIUJ IN SAV SCHEDULE J ON SHEET M2.I. '^ vJ DRIP TEE N 5. EXISTING SAV BALANCE TO VALUES SHOWN IN SAV SCHEDULE ao PITCH DUCT MOUNTING ON SHEET M1.1. �g TED b FLANGE b. EXISTING SAV NO MODIFICATIONS. III:"INSULA �L 7 STEAM H055-, VERIFY SIZES AND HEADER SE LY1les g TRAPS WITH 6" 1. RELOCATED SAV.REHEAT COIL NOT REQUII;MD,COOLING IF'" F MANUFACTURER�� ONLY, l r#15-310 S PIPE CONDENSATE LINE BACK AND di SLOPE all S. CONNECT TO EXISTING HWS 4 HWIR LINES AND PIPE TO NEW PROJECT DATE - TERMINATE OVER FILL CUP WITH AIRCOIL. GAP PER MANUFACTURER INSTRUCTIONS g" 15008 W20-2015 o \�� gLOPE S. IN-DUCT STEAM DISPERSION ASSEMBLY FOR HUMIDIFICATION. VERIFY SIZES AND TRAPS DRAWN CHECKED F °4"CONDENSATE LINE WITH MANUFACTURER AS MG HUMIDIFIER SLOPED PER CODE. j EXTENDED-"-- CUP REVISED:Q # Descriplim Data VERIFY WITH ST.LUKE'S MAINTENANCE 7�PERSONNEL MOUNTING HEIGHT FOR MAINe RVCE Or HUMIDIFIER ANCE AND £R PROVIDE WALI L MOUNTING L I SUPPORT AS REQUIRED. SHUT-OFF HUMIDIFIER BALL VALVE PIPING RACKED ON WALL JC ` UNIT DRAIN o V OUTLET v,COPPER \, o SUPPLY LINE `PROVIDE 3"TAPERED FITTING ON I" STRAINER DRAIN LINE. ALLOW I"AIR GAP BETWEEN KEYPLAN TOP OF TAPERED FITTING AND UNIT S P£TE'S PLUG(TYP., \ cycHYDRONIC DRAIN OUTLET PER CODE, mm `I"DRAIN LINE ROUTED �3,FLOOR SINK IN MRI ' 1 AT �WSTALL WMANUAL IHGNOPOININT T£OF SLOPE DEMOLITION _ IZ BRANCH PIPING RUN COMPUTER ROOM. TERMINATE DRAIN LIE OVER a �I� FLOOR SINK PER CODE. 4` / VAV VALVE ILSS.. / & REMODEL REDUCER(TYPJ �I i �--CIRCUIT SETTER BALANCE VALVE N��INSTALL HUMIDIFIER AND DUCT DISPERSION EXISTING TENANT PLANS SPACE TO REMAIN IAIION(TYPJ ASSEMBLY PER MANUFACTURER'S RECOMMENDED INSTALLATION. ILI L STRAINER GATE VALVE CTYP.)-/ 4N 2. REFERENCE MANUFACTURER'S INSTRUCTIONS SHEET FOR ALL ADDITIONAL REQUIREMENTS FOR NS HYDRONIC RUN OUTS m INSTALLATION.NOTE: SHUTOFF VALVES TO BE BALL VALVES FOR PIPE TO VALVE COILS R 5UT 2"AND A. �+ SMALLER,PROVIDE BUTTEI;U:I.Y 1 VALVES FOR LAIW.E SIZES,d 0-2°''G AREA OF WORK C �1 HOT WATER HEATOVG HEATING COQ. PPOVG DETAL �_ H-1 F ER PIPING SCI-EMATIC 2b-55 GPM I" w �- SCALE:NONE --r SCALE;NONE 5b-10 GPM N" P_4• 3 11 21, U GENERAL NOTES 3' —Rol A. ALL WORK WITHIN CONTRACTOR'S SCOPE SHALL COMPLY 2"V.U z" rx WITH ALL APPLICABLE STATE 4 LOCAL CODES!ALL w2 2"V.UP © 9 REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. B. COORDINATE PLUMBING FIXTURES AND RELATED PIPING WITH 'r2" 2"V P �L — '^'.� B ALL OTHER TRADES AS REQUIRED. msamxx 4'S 5 2 - C. ITEMS BEING DEMOLISHED ON THE WASTE OR PLUMBING 4" PLANS WILL BE SHOWN AS A DARK DASHED LINETYPE AND UNLESS NOTED OTHERWISE AIRS TO BE REMOVED. 1 6 D. PROTECT LOWER LEVEL AS REQUIRED FOR INSTALLATION OF NO 2" X �110" 1 WASTE PIPING. 0 �� E. CONTRACTOR TO PROVIDE FOR REPAIR AND PATCHING a i Co I I ? IU¢"V UP '1 0 BACK ANY HOLES IN WALL ABOVE CEILING THAT RESULT 4 M / 1 1 FROM DEMOLITION AND/OR INSTALLATION OF PLUMBING (� emu* 1�= I1 3 ITEMS. x axi a QI O O O ' F. SEAL ALL PENETRATIONS OF FAZE-RATED ASSEMBLIES WITH ^+" UL.APPROVED FIRE-RATED SYSTEM. REFER TO 4 2„ I 2" _ _ ARCHITECTURAL DRAWINGS, y I 2 1 ' TW `1: I'" G. ON THE WASTE OR NEW PLUMBING FLANS THE EXISTING l 2"C i� _ PIPING WILL B£SHOWN IN A LIGHTER LINETYPE FOR CLARITY 11 I"TW 4 ao AND THE NEW PIPING WILL BE SHOWN AS A DARK LINE. 6 g 1 I 1 4"W UP H, REFER TO ARCHITECTURAL FLOOR PLANS FOR EXACT "O /! FIXTURE LOCATIONS AND MOUNTING HEIGHTS.I. 2 CWITHIFY STRUCTURAL MEMBERS NEW PIPIW-PENETRATIONS THROUGH FLOOR SLAB $ J. ACCESS PANEL LOCATIONS MUST BE COORDINATED WITH F "UP TO1 EITHER ARCHITECT OR GENERAL CONTRACTOR K REFER TO FIXTURE SCHEDULE FOR SIZES OF WASTE,VENT,HW �I' �/� ' • j; / /� 1 4"W D O AND CW KNOUTS TO FIXTURES.WHEN PIPE IS LABELED ON W a rl Q DRAWING,DRAWING TAKES PRECEDENCE. 1�1 a I ^l o - I , o 'I III KEY NOTESr. �o I. 2"WASTE LINE UP THROUGH FLOOR ABOVE INTO EXISTING � •rl z vJllJ d WALL TO SERVE P-I•SINK FIXTURE LOCATED ON FIRST FLOOR REFER TO THE LEVEL I-PLUMBING PLAN THIS SHEET FOR I FIXTURE. FIELD VERIFY AND COORDINATE WITH EXISTING O STRUCTURAL MEMBERS,ITEMS AND CONDITIONS FOR CORE Q I DRILLING OF FLOOR FROM ABOVE. 1 1 2. TIE NEW 2"WASTE LINE INTO EXISTING WASTE MAIN. VERIFY J AND COORDINATE WITH EXISTING CONDITIONS, �Y= 3. TIE NEW t2"HW LINE INTO EXISTING HW MAIN. PROVIDE SHUT P. . I VALVE. VERIFY AND COORDINATE WITH EXISTING CONDITIONS. m 4. FIELD VERIFY EXISTING'r2"OW LINE VALVE AND CAPPED IN CEILING SPACE. REMOVE CAP AND CONNECT NEW CW LINE 1 LEVEL 0-WASTE AND VENT PLAN 2 LEVEL `I- PLUMBING PLAN AND ROUTE TO FIXTURE IN ROOM. VERIFY AND COORDINATE J WITH NEW AND EXISTING CONDITIONS. M1.1 1/8"=1'-0" M1.1 118"=1'-0" S. FIELD VERIFY EXISTING 2"VENT RISER AND TIE NEW 11/2"VENT Lu I- LINE INTO EXISTING VENT RISER VERIFY AND COORDINATE J m w WITH EXISTING CONDITIONS. Im Q Lu m 3 6. DUCT HUMIDIFIER INSERTION TUBE. a a 0 L t:z Zuio_ci of N z �� m \ =No / J 1 n aw a � ui a 1\� Jf;EL St Ldws w 1 r#15-310 r 0 a PROJECT DATE 15005 05-20-2015 F o DRAWN CHECKED AS MG N O REVISED:Q H # 1 Dowiplion Date 3 0 E m 0 N Z 3 a O V- O O KEYPLAN SHEET nnE PLUMBING TE/� REMODELSHEET E EXISTING SPACE TO REMAIN > E N SHEET o a AREA OF WORK TP 1 ■ 1 L a z w GENERAL NOTES A. CONTRACTOR TO INSTALL ALL MEDICAL GAS PIPING IN ACCORDANCE WITH ADOPTED U.P.C.AND NFF"A S-- B. CONTRACTOR TO COORDINATE REQUIREMENTS WITH MEDICAL GAS SUPPLIER GENERAL CONTRACTOR AND OWNER FOR EXACT ROUGH-IN LOCATIONS. C. MEDICAL GAS AND VACUUM PIPING SHALL BE LISTED TYPE K OR'L'COPPER MEDICAL GAS TUBE. D. ALL PIPING,VALVES AND FITTINGS SHALL BE CLEANED INTERNALLY TO REMOVE GREASE,OIL AND OTHER OXIDIZABLE MATERIALS PRIOR TO DELIVERY TO SITE. £. BRAZING OF ALL JOINTS SHALL BE PERFORMED IN an co' 6 00 J ACCORDANCE WITH ADOPTED U.P.G.AND NFPA.99. MN o F. WHILE BEING BRAZED,JOINTS SHALL BE CONTINUOUSLY PURGED WITH OIL FREE DRY NITROGEN TO PREVENT THE B v\ FORMATION OF COPPER OXIDE ON THE INSIDE SURFACE OF THE JOINT. THE FLOW OF PURGE GAS SHALL BE MAINTAINED UNTIL THE JOINT IS COOL TO THE TOUCH. , MEDICAL GAS TESTING SHALL BE PERFORMED IN ACCORDANCE WITH ADOPTED U.P.C.AND NFPA.SS. H. MAXIMUM PIPE HANGER SPACING SHALL BE PREFORMED IN <g ACCORDANCE WITH NFPA t9: Vi" PIPE -6 FEET y1 P PIPE -8 FEET 'S I1/2"PIPE -10 FEET I. LABEL PIPING IN CEILING SPACE AT 20'INTERVALS. J. PROVIDE 20"CLEARANCE BELOW WALL MOUNTED MEDICAL GAS OUTLETS AND 10"ABOVE EACH OUTLET. O 4,C LABELING OF ALL MEDICAL GAS LINES TO BE PER NFPA 99. e tr.i�F- L. MEDICAL GAS LINE BALL VALVES LOCATED ABOVE CEILING A$1-Nl R' SPACE TO BE LOCKABLE TYPE. W O G. 02 I O 0 ✓ MA Z 1I4"VAC •1 .:'N"' O —/ o ° ® FF.1 OE. 1 I»5W ,2"02 V2"MA / 02- MA 1 I"VAS Z15-2 co NV N20 1 / - W cot J zo 2,11 02 co MA. ' / MA -- KEY NOTES ."VAC 1 _ N20 2 L 1 ® I. REMOVE FLOOR MOUNTED PEDESTAL OUTLET BOX.PROVIDE 2 2 N / FOR PATCHING REMAINING FLOOR PENETRATIONS. LLI cn CO2 j 1 1 1 1 ,mrr �J `J J c a 1� n 2. REMOVE EXISTING MED GAS<VACUUM PIPING,BACK TO W Q � 3 m ¢ M� dj Q ACTIVE MAINS IN IST FLOOR CEILING 4 CAP. U Q S 3 ' 3. EXISTING 02,MA 4 VAC WALL OUTLETS.PROVIDE FOR 4 Cm r o H INSTALL ONE ADDITIONAL 02 AND VAC OUTLETS ADJACENT c L o TO EXISTING OUTLETS. Z Z Z a 744 m > / 4. CONNECT TO 4 EXTEND 02,MA 4 VAC LINES TO NEW WALL 4 N J = $o 0 I"VAG 4 �® 2 1 INSTALL 2-02,I-MA 4 2-VAC OUTLETS.VERIFY EXACT `` N N N 1t11 Q�z"MA L� �L LOCATIONS WITH ARCHITECTURAL DRAWINGS. C/C J id d 1 O .y�o I C ,j42Y A - _ tMA ♦/� I"VAC vJ OHO a 1"VAC,!'I MA,t12 A , 1 Ij2CCONNEG IFOR ON. FUTURE L I.(..,,S`L eS �.. I P p F #15-310 , MA I"VAC PROJECT DATE 0 15005 05-20-2015 F 1 c DRAWN CHECKED AS MG REVISEDQ ' I # I Descdptlon Date CJ m 1 LEVEL 0- MEDICAL GAS PLAN M2.2 Mz2 LEVEL 1- MEDICAL GAS PLAN 118"=,'-0" 3 F m KEYPLAN SHEET TITLE 0 MEDICAL E GAS PLANS EXISTING TENANT > SPACE TO REMAIN N SHEER 0 a AREA OF WORK P2. 1 P2■ 1 a z GENERAL NOTES A PROVIDE FOR MODIFICATIONS TO EXISTING FIRE SPRINKLE SYSTEM,FOR COMPLETE COVERAGE OF REMODELED SPACES IN ACCORDANCE WITH NFPA PAMPHLET 13 AND ALL 1)FP1.1,NFPA 13 APPLICABLE CODES. REFER TO ARCHITECTURAL DRAWINCs5 a.The Sprinkler system shall be extended,altered or augmented as necessary to continue protection.Should FOR COMPLETE ROOM NAMES,SECTIONS,DETAILS A BUILDING Sprinkler System alterations be substantial in nature,plans shall be submitted to the State Fire Marshal for review. PLANS. COORDINATE FIRE PROTECTION LINES 1 EQUIPMENT WITH ALL Automatic Sprinkler System Plans are required when, TRADES AS REQUIRED. a.There is a relocation of 15 or more or an addition of 10 or more sprinkler heads to a system. VERIFY ALL WORK REQUIREMENTS 4 BUILDING CONSTRUCTION b.Anytime conventional sprinklers and piping are replaced with flexible piping and sprinklers. WITH ARCHITECTURAL DRAWINGS. c.Changes to piping that require seismic bracing. SNr phi d.Anytime there are changes to areas that are considered the most demanding design density flow area. �. STATE FIRE MARSHAL i LOCAL FIRE DEPARTMENT MUST BE � Di , e.Increase of building area and/or an increase of the system design density. NOTIFIED TO WITNESS THE'Me"FQIR THE FIRE"WICLER' ae Co e'W f.At the discretion of the fire official,that may consider that there is sufficient change to the system and that the *STEM 4 THE FIR!ALARM SYSTEM. CO(S o J minimum design density requirements and/or seismic bracing requirements must be verified, l sus -qp Note:Sprinkler head addition limitation to a system is cumulative.Meaning:if 10 sprinklers require a permit or 1- CONTRACTOR SHALL BE LICENSED BY STATE FIRE plan review and 9 sprinklers are added one month and 1 sprinkler a month later,it does not negate obtaining a MARSHALL. b M\Cs permit or plan review.As soon as 30 sprinklers,cumulative,are modified or added,then a plan review and construction permit would be required. y g.If no sprinkler plans are required,the sprinkler contractor shall provide a scope of work document indicating what work was done and that the system is back in service.This document shall be submitted to the City Fire Marshal prior to the request for a Final Inspection and or the Certificate of Occupancy. Sprinkler System Plans `g a.If required,the sprinkler plans shall be submitted to the State Fire Marshal for review.The approved system v shall be installed according to the approved plans.Any alterations shall be submitted to the Fire Marshal for review and approval with the concurrence of the State Fire Marshal.All documentation requirements shall be submitted prior to the request for a final inspection. M Idaho State Fire Marshal dry^] 700 West State Street,31°Floor Boise,Idaho 83720 Cs1 •l`Py Q 1■�OC, 0. a ' 1 L I 0 o J —® I 2 1 m / KEY NOTES 1 I. WORK AREA.COORDINATE PHASING OF CONSTRUCTION w I 1 EQUIPMENT INSTALLATION. W J.y 1COORDINATE PLACEMENT OF HEADS W/CEILING SYSTEMS, Q W ca N EQUIPMENT SUPPORTS,LIGHTING,MECHANICAL!OTHER U Q �� TRADE INSTALLATIONS SCHEDULE5 TO BE INSTALLED IN FINISHED CEILINGS. Q to L,N — 7 lOAO Z Z �Z-V V M w N � =�N W $oo YI N N N L tl a J o *� a a St Lye's r#15-310 PROJECT DATE a 15005 05.21).2015 o DRAWN CFECKED O � F AS MG J REVISEM L # DeaOri 'on Data a 3 O d m 1 LEVEL 1- FIRE PROTECTION PLAN 0 3 Q tt 0 F O O m KEYPLAN SHEET TmE m a FIRE PROTECTION EXISTING TENANT PLAN SPACE TO REMAIN SHEET N N R a AREA OF WORK ■ F z z w ABBREVIATIONS ONE-LINE DIAGRAM LEGEND POWER&CIRCUITING LEGEND COMMUNICATION LEGEND GENERAL ELECTRICAL NOTES ABBREV DESCRIPTION ABBREV DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION-SUBSCRIPT IDENTIFIERS MOUNTING J-BOX GENERAL NOTES: A AMMETER,AMPERE,AMBER M MUSIC SYSTEM CONTACT-NORMALLY OPEN WITH NEMA SIZE 9 SINGLE CONVENIENCE RECEPTACLE HT-CTR TYPE AF AMPERE FRAME MACH MACHINE —��— INDICATED AS APPLICABLE U.N.O. U.N.O. G1. PROVIDE FIRESTOPPING FOR ALL FLOOR AND FIREWALL PENETRATIONS.SITE AFD ADJUSTABLE FREQUENCY MCC MOTOR CONTROL CENTER DUPLEX CONVENIENCE RECEPTACLE-SUBSCRIPT ID. PS VERIFY FIREWALL LOCATIONS OR DETERMINE FROM ARCHITECTURAL REFERENCE NURSE CALL SYSTEM POWER SUPPLY DRIVE MDC MOTORIZED DAMPER CONTACT-NORMALLY CLOSED WITH NEMA SIZE C -CLOCK HANGER TL-TWIST LOCK CONTROL ❑ +46" G PLANS.DEVICE BOXES ON OPPOSITE SIDES OF FIRE WALLS(11HR AND 2 HOUR AFF ABOVE FINISHED FLOOR — INDICATED AS APPLICABLE - CR -CORD REEL WP-WEATHERPROOF �. WALL CONSTRUCTION)SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF AT ANN. ANNUNCIATOR MED MEDICAL S -SURGE SUPPRESSION P NURSE CALL STATION: LEAST 24 INCHES.OUTLET BOXES SHALL BE OF STEEL CONSTRUCTION,NOT OVER AS AMMETER SWITCH, MERC MERCURY VAPOR S OVERLOAD RELAY HEATER A -MARQUEE SEE ARCH E 16 SQUARE INCHES IN SIZE,WITH NO MORE THAN 100 SQUARE INCHES OF TOTAL AMPERE SENSOR MH MANHOLE (ALPHA NUMERIC DESIGNATION BY DEVICE/CONNECTION B -CODE BLUE STATION +64" E BOX OPENING FOR ANY 100 SQUARE FEET OF WALL,OR BE LISTED AND RATED FOR ASU AIR SUPPLY UNIT MMP MECHANICAL MONITORING MAGNETIC STARTER WITH NEMA SIZE INDICATED POINT INDICATES PANEL CIRCUIT;SEE PLAN NOTES) C -COMMUNICATION RECEPTACLE +16" E USE IN FIRE WALLS. AT AMPERE TRIP PANEL CC -CALL CANCEL BUTTON +54' E ATC AUTOMATIC THROWOVER MO MOTOR OPERATOR _ CIRCUIT BREAKER,MAGNETIC TRIP ONLY,FRAME � OR DOUBLE DUPLEX CONVENIENCE RECEPTACLE D -DUTY STATION +54' A G2. CONTRACTOR SHALL VERIFY ALL ELECTRICAL DEVICE LOCATIONS.ESTABLISH CONTROL MS MOTOR STARER 100� SIZE SHOWN,3-POLE UNLESS INDICATED OTHERWISE PEDESTAL CONVENIENCE RECEPTACLE-DUPLEX,SINGLE E -EMERGENCY TOILET PULLCORD STA. +42" E MOUNTING HEIGHTS BY COORDINATION WITH ARCHITECTURAL INTERIOR 8 Sryb/ ATS AUTOMATIC TRANSFER MT MOUNT FACE UNLESS NOTED OTHERWISE El -EMERGENCY SHOWER PULLCORD STA. +72" E ELEVATIONS,OR PER ELECTRICAL SPECIFICATIONS.MOUNT RECEPTACLES IN oyy SWITCH MTD MOUNTED CIRCUIT BREAKER,THERMAL MAGNETIC TRIP SHOWN, ET -ELAPSED TIMER +54• C KNEE WELL,WHERE APPLICABLE,OR 4"ABOVE BACKSPLASH OR COUNTER WHERE �0, 'f ® DUPLEX CONVENIENCE RECEPTACLE-FIRE RATED M -MASTER STATION +18" B KNEE WELL IS NOT PRESENT.VARIATIONS SHOWN ON DRAWINGS. �� B BELL,BLUE 400 3-POLE UNLESS INDICATED OTHERWISE FLOOR POKE-THROUGH MG -MEDICAL GAS MONITORING PANEL +54" J BC BARE COPPER N NEUTRAL P -BEDSIDE STATION +48" A G3. EXISTING INFORMATION IS BASED ON ORIGINAL DESIGN DRAWINGS AND/OR ti`� BKR BREAKER NA NON-AUTOMATIC �— SWITCH-CURRENT RATING INDICATED,3 POLE ®F DUPLEX CONVENIENCE RECEPTACLE(FLUSH IN FLOOR) PIS -PATIENT/STAFF EMERGENCY STATION +54" C LIMITED SITE VERIFICATION.FIELD VERIFY ACTUAL FIELD CONDITIONS. o` BLNKT BLANKET 100 UNLESS INDICATED OTHERWISE NC NORMALLY CLOSED S -STAFF STATION +54' A BOT BOTTOM NCJB NURSE CALL JUNCTION BOX --�— FUSE-RATING INDICATED 6611,666 MULTI.OUTLETASSEMBLY-LENGTH AS NOTED SITE -STAFFIEMERGENCY STATION +54" E G4. ALL CONDUITS SHALL CONTAIN AN INSULATED GROUND CONDUCTOR,MINIMUM NIC NOT IN CONTRACT 225 L -STAFF LOCATOR +48" E SIZE AS REQUIRED PER THE N.E.C. C CONDUIT,CONTACTOR NL NIGHT LIGHT DRAWOUT CIRCUIT BREAKER, 30 @E RECEPTACLE-240V,1PH,AMPERAGE INDICATED CEILING CB CIRCUIT BREAKER NO NORMALLY OPEN KER,LOW VOLTAGE G5. THE MINIMUM SIZE CONDUCTOR SHALL BE#12 AWG COPPER,UNLESS OTHERWISE CC CONTROL CABLE NP NAMEPLATE \ — 30® RECEPTACLE-SPECIAL PURPOSE,AMPERAGE INDICATED (SQ NURSE CALL MARQUEE AUDIO W/MUTE BUTTON +48" J NOTED. CE CONCRETE ENCASED DRAWOUT FUSED SWITCH,MEDIUM VOLTAGE CONDUIT OFE OWNER FURNISHED --I]- SURGE ARRESTER (MOUNT WALL RECEPTACLES+16"AFF TO CENTER U.N.O.) NURSE CALL DOME LIGHT: G6. ALL 120 VOLT CIRCUITS SHALL HAVE A DEDICATED NEUTRAL,SIZED TO CKT CIRCUIT EQUIPMENT Z N -NURSE ALERT CEILING C MATCH PHASE CONDUCTOR,WHITE WITH TRACER.NEUTRAL TRACER COLOR CO CONDUIT ONLY(EMPTY) OL OVERLOAD RELAY c10 CAPACITOR-KVAR INDICATED EXPOSED CONDUIT AND CONDUCTORS Z -ZONE LIGHT CEILING C SHALL MATCH THE PHASE CONDUCTOR COLOR. COMM COMMUNICATION NONE-DOME LIGHT +86' C CORR CORRIDOR PAT PATIENT ----------- CONCEALED CONDUIT AND CONDUCTORS CPT CONTROL POWER V METER WITH SWITCH-SCALE RANGE SHOWN G7. RK,WHERE SHOWN,INDICATES ANTICIPATED CONDUIT LAYOUT. PAJB PAGING JUNCTION BOX 3W ROUTING ROOM STATUS DOME LIGHT SEE PLAN C ROUTING OF CONDUIT SHALL BE SUCH THAT"MAIN TRUNK"CONDUITS SHALL BE TRANSFORMER p8 PULL BOX,PUSH BUTTON V CONDUIT DOWN LOCATED ABOVE CORRIDOR SPACES AND NOT ROUTED THROUGH PATIENT CR CONTROL RELAY,CORD REEL SWITCH e--ul� GROUND Qq ROOM STATUS ANNUNCIATOR PANEL(MASER): SEE ARCH. I SPACES. CRS COATED RIGID STEEL PC PHOTOCELL --o CONDUIT UP W D -DESK MOUNTED CONDUIT PMP POWER MONITORING PANEL TRANSFORMER,SECONDARY VOLTAGES,PHASE AND W -WALL MOUNTED G8. PROVIDE AND COORDINATE DEMOLITION OF EXISTING ELECTRICAL REQUIRED CT CURRENT TRANSFORMER PMR PHASE MONITORING RELAY or— 1 CONDUIT STUBBED AND CAPPED CUH CABINET UNIT HEATER PNL PANEL ^'`"/') r '� RATING AS SPECIFIED FOR AREA OF CONSTRUCTION WITH OWNER AND IN WALLS/CEILINGS AS SHOWN Q ROOM STATUS STATION: ON ARCHITECTURAL DEMOLITION SHEET(S).SPECIFIC ELECTRICAL DEMOLITION O PNLBD PANELBOARD ® MAJOR ELECTRICAL COMPONENT OR DEVICE- S E E •SINGLE RED LENS +48" E MAY NOT BE SHOWN.MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING DEVICES DB DIRECT BURIED CONDUIT PROJ PROJECTION 25A MCC-A NAME OR IDENTIFYING SYMBOL AS SHOWN PC -PULLCORD +42" E WHICH ARE LOCATED IN UNDISTURBED PORTIONS OF THE FACILITY UNLESS M DC DIRECT CURRENT PS PRESSURE SWITCH GF 0 1 GROUND FAULT RELAY WITH C.T. NONE-4-SWITCH +qg^ E OTHERWISE NOTED.DEVICES OR HARDWARE SALVAGED FROM DEMOLITION Vim'0D DISP DISPENSER PT POTENTIAL TRAIN FROMER -___..] MAJOR ELECTRICAL COMPONENT OR DEVICE EXISTING PROCESS AND REUSED IN REMODEL CONSTRUCTION ARE ONLY SHOWN IN THE I"� O DIV DIVISION PVC POLYVINYL CHLORIDE OR INSTALLED UNDER SEPARATE CONTRACT- SURGERY PATIENT STATUS ANNUNCIATOR: NEW RELOCATED PORTIONS. p IM DWG DRAWING 480.120V NAME OR IDENTIFYING SYMBOL AS SHOWN. oM D -DESK MOUNTED 3 POWER TRANSFORMER,SIZE AND NUMBER +16" G M O�9 R RED RELOCATE INDICATED ON DRAWINGS M -WALL MOUNTED MASER +86" G G9. SCREENED DEVICES ARE EXISTING TO REMAIN,UNLESS OTHERWISE NOTED. CM 0]1N(B) BRANCH CIRCUIT PANEL BOARD W -WALL MOUNTED +86" E (FOR REFERENCE). O CD 0) E EMERGENCY RCPT RECEPTACLE ON, OFF Q OOO EF EXHAUST AIR FAN RGS RIGID RATORGALVANIZED _D �_ SELECTOR SWITCH MAINTAINED CONTACT TTCC TELEPHONE TERMINAL CABINET rh PATIENT ARRIVAL STATION: G10."R"ADJACENT TO A DEVICE INDICATES AN EXISTING DEVICE TO BE RELOCATED. a m 04 ELEC ELECTRIC RGS RIGID GALVANIZED STEEL 4' ELEV ELEVATOR RM ROOM q A -ANNUNCIATOR(CORRIDOR LIGHT) CLG E EMERG EMERGENCY RMS ROOMS m LM ERMINAL JUNCTION BOX CC -CALL CANCEL SWITCH +48" E G11.WORK WITHIN THIS FACILITY SHALL BE CLOSELY COORDINATED WITH SLHS IN (n EO ELECTRIC OPERATOR RMSQ ROOM MEAN SQUARE �C— I -RECEPTION AREA STATION(INDICATING) +48" E ORDER NOT TO DISRUPT OPERATION OF FACILITIES.COORDINATE ALL WORK J U)ETM ELAPSED TIME METER IRS RIGID STEEL CONDUIT or TIME DELAY RELAY CONTACT(TIME ACTION INDICATED (20F) 30 DISCONNECT SWITCH,SIZE INDICATED,FUSED 3-POLE, WITHIN TENANT SPACES AND OUTAGES WITH SLHS. - Q EWC ELECTRIC WATER COOLER RT REMOTE TELEMETRY _ TOR ) UNLESS INDICATED OTHERWISE.SIZE FUSE AS NOTED IC INTERCOM STATION: EXST EXISTING RVNR REDUCED VOLTAGE TO OR REQUIRED(NF INDICATES NON-FUSED). W D -DESK MOUNTED +16" E G12.PROVIDE NEW TYPEWRITTEN PANELBOARD DIRECTORIES WITH REVISED LOAD NON-REVERSING W -WALL MOUNTED + 2 �--II--=--- REMOTE DEVICE 54" G DESCRIPTIONS. LL FDR FEEDER RVR REDUCED VOLTAGE 2� CONTACTOR,MAGNETIC,NEMA SIZE INDICATED S -SUBSTATION +54" F,FU FUSE REVERSING 0 G13.PROVIDE MATERIALS AND WORKMANSHIP AS SPECIFIED UNDER THE ST.LUKE'S Z FIX FIXTURE H A 30 L LIGHTING CONTACTOR,CURRENT RATING INDICATED; LOUD SPEAKER HORN ❑ H PA (WALL-SURFACE MOUNT) STANDARD SPECIFICATIONS,DATED F DOCUMENTS, 11,,SEE UNLESS OTHERWISE FLR FLOOR SA SURGE ARRESTOR _��D FOR NUMBER OF POLES SEE,CONTROL DIAGRAM PA -PAGING SYSTEM +90^ E NOTED ON THIS PLAN.FOR REVIEW OF DOCUMENTS,SEE OWNER'S FLUOR FLUORESCENT SC SPEED CONTROL I SELECTOR SWITCH-MAINTAINED CONTACT CONSTRUCTION MANAGER. FVNR FULL VOLTAGE SH SPACE HEATER p1-- CHART IDENTIFIES OPERATION: 10 WOUND-ROTOR MOTOR,HORSEPOWER(HP)INDICATED (2) CONE TYPE SPEAKER: J NON-REVERSING SIN SOLID NEUTRAL �W (2) -PAGING ZONE(NUMERICAL,IF REOD) F'- FVR FULL VOLTAGE REVERSING SPD SPEED P SITION NONE-SINGLE CONE;PAGING AND MUSIC RE-CLG G W CKT. HAND OFF AUTO 6 MOTOR,SQUIRREL CAGE INDUCTION,HP INDICATED D -DUAL CONE SST STAINLESS STEEL X-CLOSED CONTACT O W -SINGLE CONE;WALL-SURFACE MOUNTED RE-CLG+90" G G GREEN,GROUND ST SHUNT TRIP O O INTEGRAL VOL CONTROL RE-CLG G -OPEN CONTACT STARTER MAGNETIC NEMA SIZE INDICATED,SEE V -GF GALVANIZED STA STATION 2 2'® CONTROL DIAGRAM A -REMOTE VOLUME CONTROL RE-CLG G GI GROUND FAULT SV SOLENOID VALVE � 0 INTERRUPTER SW SWITCH PUSH-BUTTON SWITCH,MOMENTARY CONTACT, M -MUSIC SYSTEM RE-CLG G GFR GROUND FAULT RELAY SWBD SWITCHBOARD —D NORMALLY OPEN 2 COMBINATION(FUSE OR CIRCUIT BREAKER AS INDICATED) NC -NOISE CANCELLATION RE-CLG G U O GND GROUND SYM SYMMETRICAL MAGNETIC STARTER,NEMA SIZE INDICATED,SEE _I_ PUSH-BUTTON SWITCH,MOMENTARY CONTACT, CONTROL DIAGRAM A VOLUME CONTROL-WALL MOUNTED(FOR +54' E Q H HIGH SPEED,HORN, T THERMOSTAT NORMALLY CLOSED SPEAKERS OF ROOM OR AS INDICATED) Z HOWLER TB TERMINAL BOARD ® CONNECTION POINT TO EQUIPMENT SPECIFIED,FURNISHED, GENERAL POWER PLAN NOTES:HH HANDHOLE TC TIME CLOCK,TIME CLOSE CURRENT TRANSFORMER,SIZE AND NUMBER AND INSTALLED UNDER OTHER SECTIONS,UNLESS ® TELEVISION DEDICATED OUTLET(SINGLE CABLE) +72" E LLI _ HID HIGH INTENSITY TO TEMPERATURE DETECTOR INDICATED ON DRAWINGS OTHERWISE NOTED.RACEWAY,CONDUCTOR AND 800.5 TO DISCHARGE RELAY 1(3) CONNECTION IN THIS SECTION. GPI.DEVICE BOXES SHALL NOT BE MOUNTED BACK- -BACK IN WALLS,UNLESS N J HPS HIGH PRESSURE SODIUM MR TIME DELAY RELAY 142 TELEPHONE/DATA OUTLET: OTHERWISE APPROVED BY OWNER. LU HVAC HEATING,VENTILATING& TJB TERMINAL JUNCTION BOX INDICATING LIGHT,PUSH-TO-TEST,LETTER AS ABOVE: # -NUMBER OF CABLES +16" E > O ®D CONNECTION TO FIRE/SMOKE DAMPER F -FIRE FIGHTER'S TELEPHONE JACK +48" E GP2.MOUNT MULTIOUTLET ASSEMBLY AND GENERAL RECEPTACLES(COUNTERTOPS AIR CONDITIONING TM TIMING RELAY A INDICATES COLOR P -PAY TELEPHONE(I-CABLE) - +48' E WITH KNEE SPACE BELOW):18"ABOVE FLOOR.(GROMMETS WILL BE PROVIDED IN d HW HOT WATER TO TIME OPEN HW DISP HOT WATER DISPENSER TR TIMER-REPEAT CYCLE w W -WALL MOUNTED(I-CABLE) +48" E COUNTER TOP BY OTHERS FOR ACCESS TO OUTLETS). Ye INDICATING LIGHT-LETTER INDICATES COLOR J OR E6 GENERAL CONTROL OR WIRING DEVICE.LETTER SYMBOLS L -WIRELESS LAN HUB(11-CABLE) CLG E GP3.ELECTRICAL DEVICES AND EQUIPMENT IN PATIENT CARE AREAS MUST MEET J O TSP TWISTED SHIELDED PAIR �( A-AMBER G-GREEN OR ABBREVIATIONS INDICATE TYPE OR DEVICE IC INTERRUPTING CAPACITY TST TWISTED SHIELDED TRIAD B-BLUE R -RED O co I&C INSTRUMENTATION AND T7C TELEPHONE TERMINAL C-CLEAR W-WHITE ❑T STEP DOWN TRANSFORMER K �/) NAVICARE KEYPAD INPUT STATION +48" K THE GROUNDING REQUIREMENTS OF NEC 517.13. V CONTROL CABINET ANALOG CLOCK SYSTEM +90" J } IJB INTERCOM JUNCTION BOX TTJB TELEPHONE JUNCTION BOX nHu (SEMIFLUSH WALL MOUNTED ALL S L Luke's ILLUM ILLUMINATOR TYP TYPICAL SECURITY LEGEND MECHANICAL UNIT IDENTIFIER,EXAMPLE SHOWN > J L ELT ELAPSED TIMER A r Health System Imc INTERMEDIATE METALLIC TX TRANSFORMER OM MOTION DETECTOR FOR DOOR CONTROL I ICNAD INCANDESCENT UC UNDER CABINET CONDUIT SYMBOL DESCRIPTION O IMP O.R.ISOLATION SYSTEM MONITORING PANEL +54" J # 15-310 INST INSTANTANEOUS UH UNIT HEATER ®A SECURITY ALARM POINT CONTACT P DOOR ACTIVATING PUSHPLATE/SENSOR(48+qFF TO CENTER U.N. .) IPCO IDAHO POWER COMPANY UVR UNDER VOLTAGE RELAY 'FLASHER"SYSTEM: GENERAL LIGHTING PLAN NOTES: U.N.O. UNLESS NOTED OTHERWISE S SECURITY PROXIMITY CAD READER(+48"AFF) ❑ REQUIRED,RED,SEE CONTROL D AGRAMSUSH BUTTON �AF GL1. REFER TO ARCHITECTURAL DRAWINGS REFLECTED CEILING PLANS FOR EXACT PROJECT DATE J,J-BOX JUNCTION BOX U.O.N ❑C PB STAFF ALERT ANNUNCIATOR CEILING J 428042.MV.09 05.29.2015 K KEY INTERLOCK ❑S E SECURITY ELEVATOR LOCKOUT CONTROL !�T QH THERMOSTAT OR HUMIDISTAT(+54'AFF TO CENTER U.N.O.; ❑'F PULL CORD STATION +42" B LIGHT FIXTURE LOCATION. V VOLTMETER,VOLT PROVIDE 1/2"C EMPTY,STUB-UP TO CEILING SPACE) GL2. ALL EMERGENCY FIXTURES SHALL BE UNSWITCHED,EXCEPT VFD VARIABLE FREQUENCY ❑g p SECURITY PANIC BUTTON(MOUNT UNDER COUNTER) VERIFY LOCATION WITH MECHANICAL CONTRACTOR. OF ROOM DOME LIGHT CLG B WHERE SWITCHING IS INDICATED BY LINEWORK TO A SWITCH. oRawRD L c8o LIGHTING CONTACTOR, DRIVE LOW SPEED VS VOLTMETER SWITCH ® SECURITY DOOR CONTACT LOS LOCKOUT STOP PUSH D SM MANUAL MOTOR STARTER SWITCH GL3. SWITCHES WITH NO SUBSCRIPT CONTROL ALL LIGHTING WITHIN THE SAME ROOM,BUTTON D-INTEGRAL TO DOOR HARDWARE OR HINGE,SEE UNLESS OTHERWISE SHOWN OR NOTED. REVISEDLT FLEX LIQUID TIGHT FLEX WC WATER COOLER ARCHITECTURAL DOOR HARDWARE SCHEDULES. CONDUIT S•SURFACE MOUNTED CONTACT/MAGNET COMBO WITH GL4. CIRCUITING LINEWORK MAY BE SHOWN FOR CLARITY OF SWITCHING AND LTG LIGHTING WH WATER HEATER ELECTRICAL DISTRIBUTION EQUIPMENT IDENTIFICATION CIRCUITS,FIELD DETERMINE OPTIMUM RACEWAY AND NECESSARY WHD WEATHERP DEMAND METER TAMPER RESISTANT METAL-CLAD PIGTAIL. CONDUCTOR COUNT TO ACHIEVE INTENDED SWITCHING AND CIRCUITING. LR LATCH RELAY WP WEATHERPROOF R-FULLY RECESSED CONTACT/MAGNET COMBO INSTALLED IN 3 N L B DP(H1) SERVICE AREA: # NUMBER WRMR WARMER DOOR FRAME HEADER/TOP OF DOOR. GL6. ELECTRICAL DEVICES AND EQUIPMENT IN PATIENT CARE AREAS MUST MEET XFMR TRANSFORMER D SECURITY DOOR LOCK CONNECTION(LOCK BY OTHERS) (Z) =CENTRAL UTILITY PLANT (H1)=DIAGNOSTIC&TREATMENT THE GROUNDING REQUIREMENTS OF NEC 517.13. - D-INTEGRAL TO DOOR HARDWARE OR HINGE,SEE (N) -I NORTH T TOWER- (ELEC SERVICE LIGHTING&SWITCHING LEGEND (H2)=DIAGNOSTICTREATMENT R E#2) MENr- ARCHITECTURAL DOOR HARDWARE SCHEDULES. (0) =MEDICAL OFFICE BLDG (ELEC SERVICE#2) SYMBOL DESCRIPTION-SUBSCRIPT IDENTIFIERS S-ELECTRIC STRIKE IN DOOR FRAME LATCH. (11) =MST[(ELEC SERVICE#1) MOUNTING REFERENCE: POLE MOUNTED FIXTURE M-MAGNETIC LOCK ON DOOR FRAME HEADER. (12) =MSTI(ELEC SERVICE#2) HT-CTR-MOUNTING HEIGHT TO CENTER EQUIPMENT: GENERAL COMMUNICATION PLAN NOTES: RE-CLG-MOUNTING RECESSED IN CEILING ® ® CEILING MOUNTED FIXTURES O y SECURITY MOTION SENSOR-ARROW INDICATES MCC =MOTOR CONTROL CENTER (BLANK)=PANELBOARD GC1. ALL CONDUIT FOR COMMUNICATIONS SYSTEMS SHALL BE 3/4"MINIMUM UNLESS �-�--, S DIRECTION OF SENSING; NS INDICATES DP =DISTRIBUTION PANELBOARD OTHERWISE NOTED. SENSING IN ALL DIRECTIONS SWGR=SWITCHGEAR PDU =POWER DISTRIBUTIO LUMINAIRES BW =BUSWAY UNIT JUNCTION BOX PES: GC2. CONTRACTOR SHALL ONLY INSTALL CONDUIT AND JUNCTION BOXES FOR THE WALL MOUNTED FIXTURES (SEE LUMINAIRE Q' SECURITY CAMERA,PTZ-PAN,TILT,ZOOM IS =ISOLATION POWER PANEL UPS =UNINERRUPTIBLE A -4-GANG x 3 1/2"DEEP FOLLOWING COMMUNICATIONS SYSTEMS PER THE COMMUNICATION DRAWINGS: SCHEDULE FOR TYPE) POWER SUPPLY 7� TRACK MOUNTED FIXTURE SM SECURITY MONITOR AND MULTIPLEXER B -4"SO x 2 1/8"DEEP W/1-GANG PLASTER RING DATA/TELEPHONY.WIRING AND DEVICES SHALL BE]NSTALLED BY THE QUALIFIED SEQUENTIAL LETTER IDENTIFIER A,B,C,ETC.: C -4"SO x 3 1/2'DEEP W/2-GANG PLASTER RING CONTRACTORS FOR THESE SYSTEMS.ALL OTHER SYSTEMS SHALL BE PROVIDED (ALL EQUIPMENT SHARING THE SAME LOCATION AND POWER TYPE WILL D -4"SQ x 2 1/8"DEEP FOR CONVENIENCE RECPETACLE COMPLETE,UNLESS OTHERWISE NOTED. 3� Ill f V. EMERGENCY FIXTURES EEO SECURITY CONTROL,BATTERY OPERATED BE ASSIGNED A UNIQUE ALPHABETIC IDENTIFIER) AND 4"SO x 2 1/8"DEEP FOR TELEVISION CABLE OUTLET, GCS. MOUNTING HEIGHTS AS INDICATED UNLESS OTHERWISE NOTED ON SH ET TITLE (BY OTHERS,SHOWN FOR REFERENCE ONLY) BOTH W/1-GANG PLASTER RINGS.INSTALL I'MIN.APART. ARCHITECTURAL DETAILS.CONFIRM ALL HEIGHTS WITH OWNER PRIOR TO VOLTAGE LEVEL: E -4"SO x 2 118'DEEP Will-GANG PLASTER RING INSTALLATION. ® EXIT LIGHT SINGLE FACE(SEE LUMINAIRE SCHEDULE) REX D REQUEST TO EXIT SIGNAL DEVICE L=LOW(208Y/120 VOLT) H=HIGH(480Y/277 VOLT) F -7 3/4"W x 1O"H x 2 3/4"DEEP ELECTRICAL D-INTEGRAL TO DOOR HARDWARE OR HINGE,SEE G -FURNISHED BY SPECIAL COMM.SYSTEMS CONTRACTOR GC4. CONTRACTOR SHALL INSTALL 3/4"CONDUIT FROM OUTLET BOX TO NEAREST QQ EXIT LIGHT DUAL FACE(SEE LUMINAIRE SCHEDULE) ARCHITECTURAL DOOR HARDWARE SCHEDULES, POWER TYPES: H -4'x 3 1/2'DEEP W11-GANG PLASTER RING ACCESSIBLE SPACE IN CORRIDOR CEILING AND STUB OUT FOR TELEPHONE, LEGEND CX N=NORMAL M=EMERGENCY MECHANICAL I -16"W x 16'H x 4•DEEP TELEVISION AND COMPUTER DATA COMMUNICATIONS SYSTEMS CABLES. X EXISTING LIGHT FIXTURE-FOR REFERENCE ONLY P-PASSIVE INFRARED DETECTOR MOUNTED ABOVE DOOR E=EMERGENCY L=LIFE SAFETY CABLES NOT ENCLOSED IN CONDUIT SHALL BE SUPPORTED BY CABLE RING GENERAL FRAME.PROVIDE J-BOX TYPE'B'HORIZONTALLY MOUNTED C=EMERGENCY CRITICAL U=UNINTERRUPTIBLE I UPS J -AS SPECIFIED/REQUIRED 6"-12"ABOVE ACCESSIBLE CEILING,8'ON CENTER,MAXIMUM. ®X R EXISTING LIGHT FIXTURE RELOCATED 6"ABOVE DOOR FRAME. K -4"SQ x 2 1/8"DEEP W/2-GANG PLASTER RING Se FT2T LOWER CASE SUBSCRIPT LETTER IDENTIFIES LOCATION: GC5. CONDUIT SYSTEMS SHALL BE IDENTIFIED BY DIFFERENT COLOR PAINT,AS NOTES FLOOR g COMMON SWITCH AND LUMINAIRE CIRCUIT g K SECURITY KEYPAD S=SITE P=PENTHOUSEIN UNFINISHED SPACES. DIRECTED BY OWNER,ABOVE ACCESSIBLE CEILINGS AND WHERE EXPOSED B=BASEMENT # FLOOR NUMBER S WALL SWITCH(+48"AFF TO CENTER U.N.O.) NOTE' GC6. CONDUIT STUBBED OUT IN CEILING SPACE SHALL BE NO MORE THAN 6%12" sneer NONE SINGLE POLE K -KEY OPERATED ® SECURITY ALARM PANEL FOR TRANSFORMERS,AUTOMATIC TRANSFER SWITCHES,AND MANUAL ABOVE DROPPED CEILING.MOUNTING HEIGHTS SHALL BE AS INDICATED 2 -DOUBLE POLE LV-LOW VOLTAGE TRANSFER SWITCHES,IDENTIFICATION SHALL BE AS FOLLOWS: UNLESS OTHERWISE NOTED ON ARCHITECTURAL DETAILS.CONFIRM ALL 3 -THREE WAY OS-OCPILOT LIGHT CUPANCY SENSOR 4 FOUR WAY P - TRANSFORMERS• HEIGHTS WITH OWNER PRIOR TO INSTALLATION. - B "SWITCH RANK WP-WEATHERPROOF TX-'LOAD IDENTIFICATION',WHERE TX=TRANSFORMER, GC7. ALL DATA/TELEPHONY STATION CABLES FOR OUTLETS SHALL BE ROUTED �E-1 ■ - D -DIMMER AND TOAD IDENTIFICATION'IS DEFINED ABOVE. FROM THE OUTLET TO THE IDF FOR THE ENANT SPACE,UNLESS IC -INTENSITY CONTROL GENERAL LEGEND NOTE: EXAMPLE:TX.3NLBDP(H1) OTHERWISE NOTED. THIS IS A STANDARD LEGEND SHEET.SOME SYMBOLS OR TRANSFER SWITCHES: . TELEVISION pg OCCUPANCY SENSOR,CEILING MOUNTED, ATS-'LOAD IDENTIFICATION',OR MIES-'LOAD IDENTIFICATION;WHERE T THE TELEVISIONS OR OUTTER FOR THE BUILDING. DUAL TECHNOLOGY ABBREVIATIONS MAY APPEAR ON THIS SHEET AND NOT ON THE PLANS. GCB TLEVISION CABLES FOR OUTLETS SHALL BE ROUTED FROM THE OUTLETS ATS=AUTOMATIC TRANSFER SWITCH;NITS=MANUAL TRANSFER SWITCH EXAMPLE:ATS-3NL13DP H1 R sryy zw MR;� w� ..t{L.—.—•''" ...,-, —�FF.1 TOILET s o � MGR OFFICE � ', I H1465 I - d I j - POWER PLAN DEMO NOTES: / HALL ( (FOR LEGEND AND GENERAL NOTES,SEE SHEET E1.0;FOR LOCATION PLANS,SEE SHEET E2.3,AND E2.3.1) 484 Z — 1 HALL H1 ' I _ PD1. GENERAL NOTE: DEVICES SHALL BE CIRCUITED ACCORDING TO THE FOLLOWING SCHEDULE: ' SOIL ROOM P -_.� NC=1NLD(H1) ES=1CLB(H1) LB=1LLB(H2) I 1' ' H1/ I I �Ht463 I, Hta6D P e NO=1NLD(H1) EN=1CLN(H1) EQ=BCHQ(H1) M NP=INLP(H1) ER=1CLR(H1) P, { (A 0 �°Do - Ht�D j PD2. GENERAL NOTE: BRANCH CIRCUITS ARE EXISTING TO TENANT IMPROVEMENT SPACE,UNLESS OTHERWISE 0 ��U 1 � I NOTED. EXTEND EXISTING CIRCUIT CONDUCTORS AS REQUIRED. CIRCUIT ASSIGNMENTS OF PLAN SHOULD M a—to 1 DICTATION , BE ADJUSTED TO POLE POSITIONS MOST LOGICAL,GIVEN EXISTING FIELD CIRCUITING. 0 ce) m dM H1468 I,I I , Q O OO W I PD3. GENERAL NOTE: ELECTRICAL DEMOLITION INCLUDES,BUT IS NOT LIMITED TO RECEPTACLES,AND HARDWIRE CL.Do N ' 1'I 1241 CONNECTIONS. (FOR REFERENCE ONLY). Q3 J � CORRIDOR PD4. GENERAL NOTE: COORDINATE DEVICE LOCATIONS WITH ARCHITECTURAL ELEVATIONS. — J I H1185 'J D O ts4 PD5. GENERAL NOTE: PROVIDE,PRIOR TO FINAL ELECTRICAL INSPECTION,DOCUMENTATION TO SHOW NFPA 99, N - I SCHAPTER LRMC BUILDING NG COMPLIANCE SERVIC FORS. PATIENT CARE AREAS;COORDINATE WITH ELECTRICAL PERSONNEL FROM m Z I 4 CATH LAB CONTROL CT) O EN34 R i llAl A e I PD6. GENERAL NOTE:FISH 3/4"FLEXIBLE CONDUIT FOR RUNS IN EXISTING WALL,OR TO NEW OUTLET BOXES Q t�D3 Z Q Np3g ryP' CURMSQUAD MOUNTED IN EXISTING WALL. J 1 H1477 -------•-1' 1r° — _ GG PD7. GENERAL NOTE:COORDINATE CONNECTION TO FIRE/SMOKE DAMPER WITH MECHANICAL CONTRACTOR. (>n I 1 O zw CLEAN HOLD I .•-- ---- • -� 42 — H1467 1 ' 1 I z NN1 Q p H1487 BUT"CATH LAB PROCEDURE O ND3 IRP H1242 iD 1 gq EN34 28/ j N J 1 01 W - . I I > J fil H1zaz CC ' G d ,I IE ®� 3�1N42 PFF ' TYP. ®' 1 O I N4 N �, j v J CIO 1RP'� a6 OFFICE MGR 'CATH LAB JL St Luke's t I, g PROCEDURE I ® i H1478 �r Health System 5 H1241 ,R� p Ir # 15-310 1 •, � ' PROJECT DATE IIRP I 42BO42,W.09 05.29.2015 I EQUIPM H1486 11 j DRAWN CHECKED 2UG J 1120 H1468 — L��. CLC CJW I I I I REVISED IN 36 _.�.— 'I � '1 ND36 - 0 a C T Z EP7 149 N 7A OPOWER PLAN DEMO 1/4"=V-0" �� 1 6A 1 SHEET TITLE POWER PLAN DEMO SHEET 1E-D-1 2 oyb x1240 � LIGHTING PLAN DEMO NOTES: s ue"oQr � (FOR LEGEND AND GENERAL NOTES SEE SHEET E1.0,FOR LOCATION PLAN,SEE SHEET E2.3 AND 3.3.1) � s� NIGR OFFICE ';i`; 'j LD1, GENERAL NOTE: DEVICES SHALL BE CIRCUITED ACCORDING TO THE SCHEDULE AS SHOWN H1465 ''} •C,'}; ON THE POWER PLAN,SHEET E2.0. L` A.:.4• LD2. GENERAL NOTE: ELECTRICAL DEMOLITION INCLUDES,BUT IS NOT LIMITED TO SWITCHES, v'' :. WALL,UNDER CABINET,AND CEILING LIGHTING FIXTURES.(FOR REFERENCE ONLY). ' R4s LD3. GENERAL NOTE:CIRCUIT HOMERUNS/CONDUCTORS MAYBE EXISTING IN THIS SPACE, R4 R4 UNLESS OTHERWISE NOTED. EXTEND CONDUCTORS AS REQUIRED TO NEW }{1 LIGHTS/CONTROLS AND NEW PANEL LOCATIONS.VERIFY ALL CIRCUIT NUMBERS IN THE G6 R4 HALLFIELD. TYPICAL. 1464 LD4. GENERAL NOTE: WHERE CIRCUITING LINEWORK AND JUNCTION BOXES ARE NOT SHOWN, R4S N PROVIDE SIMILAR TO COMPARABLE SPACES. CIRCUIT TO PANEL BOARD AS INDICATED. 1` TYPICAL. o G6 R4 LD5. REFERENCE NOTE: WALL MOUNTED HAND SANITIZERS ARE TO BE MOUNTED A MINIMUM OF cocoo T-0"CLEAR OF ALL ELECTRICAL SWITCHES AND RECEPTACLES. r--,,; OD co XZ LD6. DEMO LIGHTING AND SWITCH IN THIS AREA.EXTEND EXISTING CIRCUITRY TO NEW LIGHTING co Kp:°In 1-466 m I DEVICES SEE SHEET E3.0. O cy)00 00 yM 1 XTcb a LOT CLEAN AND RELAMP EXISTING FIXTURES IN THIS AREA. 1 0 ON RX 1242 G uHm UAD J J i1 Aco LL + 1 coRRlpnT TE LD6 m Z R4 _ { _I NOTE LD6 x11R5 4 NOTE LD6 G6 ® J F- U— _ - + I I 1 ® = W �1241 G5 + G5 G5 �t G6 N1242 0 Q� 73 1 1 — LU +--- 5b Its _ I > W J t I _ O ; + I G6 _ a + — _ Y7 ,; L Gib I G5 - NOTE LD6 FFICE R _j —+ G Xk7b H1478 C VJ QOQ l7 JJ �b ALL St Luke's Health System Y 1 r b # 15—310 E _ G64- ++ I PROJECT DATE G5 _ .. 426042.MV.09 05.29.2015 I _„� 1 DRAWN CHECKED —i G5 I ; _ _ } N1468 CSC CJw REVISED GIS 1 1 G5 I Lam" N($TELD6 — I t SHEET ME LIGHTING PLAN N DEMO LIGHTING PLAN DEMO 1/4"=V-D" SHEET E-D-1 .3 R SW, D Oy by 3 z w Mry o w , TOILET (FF.1 1�' — a�--.----- , MGR OFFICE � 1,1 H1485 •' .1 HALL 1 H1464 I 1`' HALL_ COMMUNICATIONS PLAN DEMO NOTES: solL Room HI ' I —� (FOR LEGEND AND GENERAL NOTES,SEE SHEET E1.0;FOR LOCATION PLAN,SEE SHEET E2.3 AND E2.3.1) CD1. GENERAL NOTE: FOR EQUIPMENT SCHEDULE,SEE SHEET E2.0. I 0 , I / �•'�H1463� ' ,1 CD2. GENERAL NOTE: ELECTRICAL DEMOLITION INCLUDES,BUT IS NOT LIMITED TO TELEPHONE, CQ� NURSE CALL,AND PAGING SYSTEMS. (FOR REFERENCE ONLY). p� — L �L� 1 1 I CD3. GENERAL NOTE: UTILIZE THE CURRENT ISSUE OF THE SLRMC INFORMATION TECHNOLOGIES r M x M� 1 COMMUNICATIONS DEPARTMENT VOICE AND DATA CABLING SPECIFICATIONS FOR APPLICATION O M DAD V DICTATION I —� H1466 TO THIS PROJECT. QO O LnC? 00 1 1 I CD4. GENERAL NOTE: EXISTING CATEGORY 6 CABLES REMOVED FROM OUTLETS IN THE Q d ON _ DEMOLITIONED WALLS MAY BE REROUTED TO NEW OUTLETS,WHERE APPROPRIATE,AND DO II 1 CORRIDOR RE-TESTED FOR SPECIFIED PERFORMANCE. J J 1 i an CD5. GENERAL NOTE:ALL COMMUNICATIONS SYSTEM CABLES FOR OUTLETS SHALL BE ROUTED 11 1 j FROM THE OUTLET TO THE IDF FOR THAT FLOOR,UNLESS OTHERWISE NOTED.PROVIDE CAT.6, LL < N NON-PLENUM RATED CABLE;DO NOT ROUTE THROUGH PLENUM AIR SPACES. m Z i CATH LAB CONTROL 1 H1241A ` I I CD6, GENERAL NOTE:FISH 3/4"FLEXIBLE CONDUIT FOR RUNS IN EXISTIN W G WALL,OR TO NEW OUTLET Q 5 1 Typ BOXES MOUNTED IN EXISTING WALL. DEMO AREA s SQUAD J--.-- - ------ — — — CD ~ 1 1 CLEAN HOLD I -=r-' GG = L>U I H1467 1 ' / < Q'1 ff"E7 CATH LAB PROCEDURE O H1242 Q LLI 1'1 i N W 1 i \\ J 1 C/C ,1 ,1 'I TYP. (n 0 00 i '' } A•L I OFFICE MGR AL St Luke's '1 'CATH LAB 1 ( H1478 �r PROCEDURE I j Health System '1 11 H1241I I"I # 15-310 I ��•� I PROJECT DATE I, 428042.MV.09 05.29.2015 1 , EQUIPMENT I I •.l -"r DRAWN CHECKED 2UG , H1468 I CLC CJw REMSED 7A SHEET TITLE COMM PLAN N DEMO COMMUNICATIONS PLAN DEMO BHEET ED 1-:4 A�AAAO RAI/ A I nC I/A..I..., E.) FIRE ALARM PLAN NOTES: o (FOR LEGEND AND GENERAL NOTES,SEE SHEET E1.0;FOR LOCATION PLAN,SEE THIS SHEET) FIRE ALARM LEGEND F1. GENERAL NOTE: COORDINATE WITH OWNER TO PROVIDE VOLTAGE DROP CALCULATIONS FOR - MULTIPLE DEVICES OF SAME TYPE(ON RISER DIAGRAM) NEW OR MODIFIED NOTIFICATION CIRCUITS,CONTROL SCHEMATIC FOR MAGNETIC HELD DOORS, FAS AND SMOKE DAMPERS,(DAMPER SHALL RELEASE UPON DETECTION OF SMOKE WITH FIRE ALARM SYSTEM ASSOCIATED DUCT DETECTOR),AND LISTING/INSTALLATION INFORMATION ON ALL FIRE ALARM SYSTEM DEVICES TO CITY OF BOISE FIRE DEPARTMENT INSPECTOR. FAS MANUAL PULL STATION(+48 AFF TO CENTER) = o F2. GENERAL NOTE: INTERCONNECT THE NEW OR RELOCATED,ADDRESSABLE DEVICES INTO THE EXISTING FIRE ALARM ADDRESSABLE CABLE SYSTEM. PROVIDE PROGRAMMING CHANGES AND F� FIRE SPRINKLER WATER FLOW BELL PD pD INTEGRATION AS REQUIRED. FAS PHOTOELECTRIC SMOKE DETECTOR o F3. GENERAL NOTE: PROVIDE THE NECESSARY MODIFICATIONS TO THE FIRE ALARM SYSTEM TO ID FAS IONIZATION SMOKE DETECTOR ACCOMMODATE THE NEW FIRE ALARM STROBES BEING ADDED;INCLUDE MODULES FOR NEW «PD " STROBE CIRCUITS,NEW CIRCUIT WIRING,SYNCHRONIZED FLASH MODULES FOR ALL CIRCUITS, �D FAS HEAT DETECTOR m" AND ALL OTHER NECESSARY COMPONENTS. o O _O � FAS PHOTOELECTRIC DUCT SMOKE DETECTOR❑ o O PD - F4. GENERAL NOTE: FIRE ALARM DEMOLITION INCLUDES,BUT IS NOT LIMITED TO REMOVAL OF UNUSED r MANUAL STATIONS,DETECTORS,STROBES,AND CONTROL DEVICES. (FOR REFERENCE ONLY). FAS FLOW SWITCH (FURNISHED/INSTALLED BY OTHERS) apop PD N PODm» F5. GENERAL NOTE: PROVIDE ALL FIRE ALARM CONDUCTORS AS REQUIRED BY THE SYSTEM TS FAS TAMPER SWITCH (FURNISHED/INSTALLED BY OTHERS) r-t M MANUFACTURER IN METAL CONDUIT. SEE SPECIFICATIONS FOR INSTALLATION STANDARD. © O �oL9 FAS PRESSURE SWITCH (FURNISHED/INSTALLED BY OTHERS) M o-� F6. GENERAL NOTE: EXISTING FIRE/SMOKE DAMPERS AND ASSOCIATED SMOKE DETECTORS ARE NOT SHOWN ON THIS PLAN. 00 PIV POST INDICATING VALVE OI O oo d F7. GENERAL NOTE: PROVIDE TOTAL-COVERAGE SMOKE DETECTION TO CONTROL THE FIRE/SMOKE (X) FAS ADDRESSABLE CONTROL/RELAY MODULE. (X)INDICATES CO N O DAMPERS OF THE HVAC SYSTEM FOR THE SPACE SERVED,IN ACCORDANCE WITH LB.C.715.3.2.11 C ACTUATION METHOD 5. THE NUMBER IN PARENTHESES BY THE DAMPERS AND DETECTORS QUANTITY. J J INDICATES THE HVAC ZONE SERVING THE SPACE. ANY DETECTOR WITHIN A GIVEN ZONE WILL -U PD CAUSE THE DAMPERS OF THAT ZONE TO BE COMMANDED CLOSED,VIA AN ASSOCIATED CONTROL (X) FAS ADDRESSABLE INPUT MONITOR MODULE. (X)INDICATES N MODULE FOR THE GIVEN FLOOR. SEE ALSO,SHEET M0.3 FOR REFERENCE,HVAC SERVICE AREAS. <IM QUANTITY. m Z TYPICAL. X FAS STROBE LIGHT,WALL MOUNT(+80"AFF TO BOT.);(X) m F8. PROVIDE COMMAND/MONITOR MODULES IN SAME ROOM AS FIRE ALARM PANEL(S)FOR INTERFACE a INDICATES CANDELA RATING IF GREATER THAN MINIMUM OF 15, Q WITH DOOR HOLDERS/RELEASES FOR THIS FLOOR. TYPICAL. TYPICAL J r ° F9. PAGING SPEAKERS,AS A SUPPLEMENTARY SYSTEM USED FOR EMERGENCY CHIME AND VOICE e FAS STROBE LIGHT,CEILING MOUNT T w BROADCAST OF FIRE ALARM CONDITIONS PER CITY OF BOISE PERMIT NO.FIR99-0596,SHOWN FOR y H REFERENCE ON THIS PLAN. TYPICAL. H FAS SPEAKER,WALL MOUNT(+80"AFF TO BOT.); F �: A - - 1`70. STROBES SHALL HAVE A MINIMUM INTENSITY OF 15 CANDELA,UNLESS OTHERWISE NOTED, 'H'INDICATES HIGH SPL SPEAKER VERSION,TYPICAL Q 0 (HONEYWELL MODEL NO.SC807 SERIES)AND SHALL MEET ALL REQUIREMENTS OF ANSI 117.1. C� FAS SPEAKER,CEILING MOUNT U Q °A MOUNT DEVICES SO THAT STROBE IS+80"AFF TO BOTTOM. PROVIDE#12 CONDUCTORS(UNLESS 0 VOLTAGE DROP CALCULATIONS REQUIRE LARGER)FOR STROBES. PROVIDE SYNCHRONIZED FAS SPEAKER/STROBE LIGHT COMBO,WALL MOUNT(+80"AFF TO Q � FLASH MODULE(S)AS REQUIRED FOR ALL STROBES. TYPICAL. u� BOT.) LU N F11. PROVIDE DUCT SMOKE DETECTOR IN SUPPLY AND DISCHARGE DUCTING FROM RTU,IN ACCORDANCE FAS SPEAKER/STROBE LIGHT COMBO,CEILING MOUNT Z Z WITH MANUFACTURER'S INSTRUCTIONS. LOCATE REMOTE LED INDICATOR AND TEST STATION IN N J FIRE ALARM PLAN DEMO CEILING SPACE OF ROOM BELOW DETECTOR. PROVIDE SAMPLING TUBE FULL WIDTH OF DUCT. Wp (SUBSCRIPT) / )WEATHERPROOF \ W TYPICAL. J F12. PROVIDE A COMMAND MODULE TO CONTROL EACH NEW FIRE/SMOKE DAMPER POWER CIRCUIT. AMP FAS AMPLIFIER Do- COMMAND MODULE(HONEYWELL NO.TC810 OR APPROVED EQUAL). LOCATE MODULES IN SAME CP FAS NOTIFICATION CIRCUIT/AUXILIARY POWER SUPPLY ROOM AS FIRE ALARM PANEL(S)(SEE LOCATION PLAN,THIS SHEET). UPON SMOKE DETECTION IN C)CORRIDOR,PROTECTED SPACES,OR UPON LOSS OF POWER,DAMPERS SHALL OPERATE TO CLOSED ® ELECTROMAGNETIC DOOR HOLDER POSITION. '' ® INTERPOSING RELAY/CONTACTOR. COIL VOLTAGE AS REQUIRED. ALL St Luke's INDICATED DEVICE TO BE CONNECTED TO FACP PANEL 2,LOOP 2. INTENTION IS TO PROVIDE WIRE CONSTANTLY ENERGIZED OR'FAIL SAFE'. I-I r r Haalth System F13. DESIGNATION OF FIRE ALARM PANEL AND LOOP ASSOCIATION FOR DEVICE;EXAMPLE-'P2/L2' FAC FIRE ALARM CONTROL UNIT 'f # 15-310 LOGICAL ASSIGNMENT OF DEVICES IN RELATION TO THE FIRE SPRINKLER ZONING FOR A GIVEN FAC FIRE ALARM CONTROL PANEL RUECT RO DATE ECT SPACE. TYPICAL. P .MV.Ds os.2s.2ot5 F14. MOUNT AREA DETECTOR(RATED FOR UP TO 1500 FPM AIR FLOW)AT TOP OF DUCT UPSTREAM OF NCP NOTIFICATION CONTROL PANEL DRAWN CHECKED SMOKE DAMPER FOR SHAFT PENETRATION,IN ACCORDANCE WITH U.B.C.713-10,ACTUATION FAA FIRE ALARM ANNUNCIATOR aC C,TW METHOD 1. ALSO REFERENCE NFPA 72 HANDBOOK,FIG.A-2-10.5.2(a). COORDINATE WITH MECHANICAL CONTRACTOR AND OWNER FOR ACCESSIBILITY FROM COMMON ACCESS PANEL DOOR WITH SMOKE ISO FAS SLC ISOLATION MODULE DAMPER. PROVIDE RELAY IN BASE AND REMOTE L.E.D. FIRESTOP PENETRATION OF DUCT. TYPICAL. REVISED OTs FIRE ALARM INDICATING LIGHT(RECESSED IN CEILING) 'TS'INDICATES INTEGRAL TEST/RESET SWITCH ®D FIRE/SMOKE DAMPER CONNECTION POINT SHEET ME FIRE ALARM PLAN DEMO SHEET E-D-1:5 1 WOMENS LOCKERS STAFLWNG! _Hi472. Ht471 j V POWER PLAN NOTES: 1 I 1 TOILET -- FOR LE END AND GENERAL NOTES,SEE SHEET E1.0;FOR LOCATION PLANS,SEE SHEET E2.3,AND E2.3.1) '1 Hi472A '- o r V, P1. GENERAL NOTE: DEVICES SHALL BE CIRCUITED ACCORDING TO THE FOLLOWING SCHEDULE: z W M NJ�tiW Qi NP38,40,42"HSKP NP3 9,41` TOILET I - - '- - ----- -FF.1 NC=1NLD(H1) EB=ICLB(H1) LB=1LLB(H2) 0T P19_P: NOL,T P19 Ht24D NO=1NLD H1 EN=1CLN H1 EQ=BCHQ H1 I�Ity.'i- H H r't. MGR OFFICE•.-'' NN=1NLN(H2) EP=1CLP(H1) ( ) 1 2 NP=1NLP(H2) ER=1CLR(H1) I J� P2. GENERAL NOTE: BRANCH CIRCUITS ARE EXISTING TO TENANT IMPROVEMENT SPACE,UNLESS OTHERWISE HALL NOTED. EXTEND EXISTING CIRCUIT CONDUCTORS AS REQUIRED. CIRCUIT ASSIGNMENTS OF PLAN SHOULD 6 \ I.I NOTE P7 H1484 BE ADJUSTED TO POLE POSITIONS MOST LOGICAL,GIVEN EXISTING FIELD CIRCUITING. P3. GENERAL NOTE: ELECTRICAL DEMOLITION INCLUDES,BUT IS NOT LIMITED TO RECEPTACLES,AND HARDWIRE I 1 CONNECTIONS. (FOR REFERENCE ONLY). 1 I BCHQ31,33,35 1 SOIL R00 ML, ' } - P4. GENERAL NOTE: COORDINATE DEVICE LOCATIONS WITH ARCHITECTURAL ELEVATIONS. 1 �i3 J Ht484 1 ; P CIRCUIT fX1_-tTIN,G - P5. GENERAL NOTE: PROVIDE,PRIOR TO FINAL ELECTRICAL INSPECTION,DOCUMENTATION TO SHOW NFPA 99, 1 I DOOR H ARE I CHAPTER 4 COMPLIANCE FOR PATIENT CARE AREAS;COORDINATE WITH ELECTRICAL PERSONNEL FROM k 1 GB \\\ SLRMC BUILDING SERVICES. �co 1 1, p7 100A J- P6. GENERAL NOTE:FISH 3/4"FLEXIBLE CONDUIT FOR RUNS IN EXISTING WALL,OR TO NEW OUTLET BOXES lro r 1 I J I CONTROL ROOM MOUNTED IN EXISTING WALL. X:2 20E.8 1 - - H1242A j M m- / a P32 p[ CORRIDOR P7. ASTERISK(')SHOWN BY CIRCUIT NUMBER INDICATES DEDICATED HOMERUN TO PANEL,TYPICAL.. O 00 w NOtE P16 n H^185� 1 4•p0 55 W? v ISO 1 I P8. GENERAL NOTE:INSTALL ALL RECEPTACLES WITHIN THIS SPACE AT 36"AFF,UNLESS OTHERWISE NOTED. Q 0-m w 20F ,I 1 a ad ANGIO LAB B O P9. GENERAL NOTE:COORDINATE CONNECTION TO FIRE/SMOKE DAMPER WITH MECHANICAL CONTRACTOR. J J 2•� 1 11 I/1 0• co P10. CONTRACTOR WILL PROVIDE A STUB-UP FOR EPIC RECEPTACLE.STUB-UP SHALL BE A MINIMUM ABOVE J < A FLOOR FINISH OF 18",AND A LOCATION WITHIN SIX FEET OF EQUIPMENT. COORDINATE WITH EPIC EQUIPMENT m LLl N EQUIPMENT ROOM CITE P18 j INSTALLATION MANAGER AND ST.LUKE'S CONSTRUCTION MANAGER.SEE ARCHITECTURAL ELEVATIONS. Z 1 H1241A SO j P11. ISOLATION POWER PANEL,FED FROM UPSTREAM PANEL 1CLR(H1),ERAX 30A. SEE ALSO 1 m 1 t E ' I SEQIJWT/S6UAD 11 -1'• R17 Htan J I ' - • —-----------_-_ ------ GG P12• POST-GLOVER RECEPTACLES,USE NEW DUPLEX-CATALOG#RRP-1DOIN PROJECT AREA.TYPICAL. W ER1,7 NOTE P17 1 > DUAL PLANE LAB P13. GENERAL NOTE:IT IS ANTICIPATED THAT CIRCUIT HOMERUNS/CONDUCTORS ARE EXISTING IN 1 THIS SPACE,UNLESS OTHERWISE NOTED. EXTEND CONDUCTORS AS REQUIRED TO NEW DEVICES.H12a1 _ g NP36 1 20 � VERIFY ALL CIRCUIT NUMBERS IN THE FIELD. TYPICAL.PROVIDE NEW CIRCUIT/HOMERUN. NOTE P10 VERIFY CIRCUIT NUMBER. U Q �ER15 -ti " 41 a_ P14. GENERAL O +44,AFF ER13 NOTE: WHERE CIRCUITING LINE WORK AND JUNCTION BOXES ARE NOT SHOWN,PROVIDE Q M ER19 1 SIMILAR TO COMPARABLE SPACES. CIRCUIT TO PANELBOARD AS INDICATED,TYPICAL. LV 1 NOTE P10 CONTROL ROOM _.T P15. GENERAL NOTE: PROVIDE,PRIOR TO FINAL ELECTRICAL INSPECTION,DOCUMENTATION TO SHOW NFPA 99, N J CHAPTER 4 COMPLIANCE FOR PATIENT CARE AREAS;COORDINATE WITH ELECTRICAL PERSONNEL FROM LLl 41 NOTE P17 NOTE P 8 P H6i24/B- j SLHS BUILDING SERVICES. \ w ER 9 �R21 I 0 Ek7` d P16. PROVIDE HUBBELL HBL2315 20A TWIST-LOCK MALE FLANGED OUTLET MOUNTED FLUSH IN WALL.COORDINATE /� d �_'1 11 1 - _ ---- 4 ER15 I, SO EXACT LOCATION WITH OWNER AND EQUIPMENT MANUFACTURER PRIOR TO ROUGH-IN.SLHS TO PROVIDE J ^: 20A ER- I~ HUBBELL HBL2313 20A TWIST-LOCK FEMALE PLUG TO PHILLIPS.PHILLIPS TO CONSTRUCT AND PROVIDE CABLE '^ NP36 _ TO CONNECT FROM MALE FLANGED OUTLET TO UPS. w W - 1 I P17. PROVIDE FLUSH MOUNTED FLOOR BOX WITH HUBBELL HBL2310 M1 20A TWIST-LOCK OUTLET.COORDINATE EXACT 4 ER15 rug OFFICE MGR LOCATION WITH OWNER AND EQUIPMENT MANUFACTURER PRIOR TO ROUGH-IN.SLHS TO PROVIDE HUBBELL AL St Luke's rNOTE P18 t 03 C7478- HBL2311 20A TWIST-LOCK PLUG TO PHILLIPS.PHILLIPS TO CONSTRUCT AND PROVIDE CABLE TO CONNECT FROM r Health System NP32 PHILLIPS EQUIPMENT TO FLOOR BOX OUTLET. 'I ER19 + - NOTE PI I DSO 2 P18. PROVIDE(2)#12,1#12G,IN 1"CONDUIT TO RECEPTACLES NOTED IN NOTES P16 AND P17. # 15-310 ' I+44 AF P19. COORDINATE WITH MECHANICAL CONTRACTOR PRIOR TO INSTALLATION OF HUMIDIFIERS. PROJECT DATE I EQUIPMENT CLOSE j 428042.MV.09 0529.2015 H12428 -;} DRAWN CHECKED Sr NP32 STORAGE 1 j 1 + 44]AF NP32 Ht2atc 1 j REVISED 1 a 1 I 1 '1 ,I '1 7a 66A SHEET TITLE N POWER POWER PLAN PLAN 1/4"=1'-0" SHEET ELECTRICAL LEGEND ITEM DESCRIPTION \ REM SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR REF. MAIN MAIN SERVICE ENTRANCE PANEL 1 EJ R Sryb) CB THREE PHASE CIRCUIT BREAKER PER TOSHIBA POWER SPECIFICATIONS(SEE DETAIL} CIRCUIT race BREAKER LOCATION PER CODE:REQUIREMENTS BY ELECTRICAL CONTRACTOR. KE9 �yb CD 18"W X 12"H % 6"D J-BOX,SURFACE MOUNTED 29 1/2"A.F.F.TO BOTTOM OF BOX. e OPEN TO'VR". SEE TOSHIBA'S POWER QUALITY REQUIREMENTS FOR THE GENERATOR. E3 z w MN�2 EPO 4" STD. J—BOX FOR REMOTE OFF SWITCH. LOCATED BY CUSTOMER/CONTRACTOR. .` 1 OPOT,NORMALLY OPEN MUSHROOM HEAD PUSH BUTTON. Ey IL 4"STD-J-BOX FOR"X-RAY ON"OR WARNING LIGHT MOUNTED ABOVE PATIENT ENTRY 2 DOOR. El C. BUILDING STEEL. Ea CONTROL ROOM I B8 FLOOR.J 4'LTO HAVE REMOVABLE MOUNTED UNDER COVER. WITH B"CORE DRILL THRU F- H12azA TOSHIBA INFINIX SELECT NOTES: 1. I CAT 10"W X 10"L X 6" D J-BOX,MOUNTED UNDER FLOOR WITH 7"CORE DRILL THRU FLOOR, J N E1. GENERAL NOTE: TOSHIBA INFINIX ANGIO LAB COMPONENT DESIGNATIONS ARE AS 1 I JC 'MI , FOLLOWS;ALSO REFER TO TOSHIBA DRAWINGS TO DETERMINENERIFY ALL S} 1 INSTALLATIION REQUIREMENTS;AND FOR CATALOG NUMBER RECOMMENDATIONS MS 10'W X 10"L X 8"0 J—BOX, FLUSH MOUNTED IN FINISHED CEILING. 4 'I ANclo FOR COMPONENTS TO BE PROVIDED BY CONTRACTOR: Es '1 'JFJB' 11 H12a I CCB 0'1 AW SHARED 8'W X 3"H GROMMETED OPENING IN WALL DUCT"WD3". c�i S2 11 g ON E3 0000 R L' r- c)0 'INJR' II 11 AWS e W X 3"H GROMMETED OPENING IN WALL DUCT"WD3'. CO 0:2U) 1 O V � ED O7 M W 3, w WCU 1 OS GC SHARED 8"W X 3"H GROMMETED OPENING IN WALL DUCT'WD1". Q 0 D mN I CC J W LANE LAB {� I 1 1��pNW J 1 ' J 1241 "3 1, � I RAID 8"W X 3"H GROMMETED OPENING IN WALL DUCT"WDT". I I i 0 I 1 MS', LLI W OJT ,P 1 INV LOCATED ON SHELF. Z 1 ' m v 5 GROMMETED OPENING AT END OF WALL DUCT, "WD1"AND"WD2". OPEN TO XTP-810OG 4 - GENERATOR CABINETS. CONTROL ROOM M' CEILING CONDUIT SCHEDULE wJ CONNECTS TO 'PHI "J F JI I I CONTRACTOR CONDUIT REFERENCE CABLE REFERENCE 2 LLI INJC .1 'ce 0-4 1 RUN CONDOR OONDUIT CONDUIT CABLE CABLE LENGTH CABLES SHARED 8"W X 3"H GROMMETED OPENING IN "WD3". EJ Q I I I NIL (POINTTOPO641] (DIAMETER) (MAX.LENGTH) (POINTTOPOINT) (USABLE) {SUFPLIEDBYj INJR 1 II III JB} RSL PER CODE PER CODE CD RSL PER CODE ' CONTRACTOR TITS 11"W X 8"L X 5"D. STEP-..DOWN TRANSFORMER,TO BE LOCATED ON SHELF 0 1111 I (BY CUSTOMER/CONTRACTOR)ABOVE "PCDU'AS LONG AS LOCAL CODE ALLOWS. 7Q W B$', O M5 JBi. (3} 2" 68'-0" MS OF'P DETAIL(.1/Et) T05HIELA MIC B"W X 3"H GROMMETED OPENING IN WALL DUCT'WD3". E3 Z Z 1 'INV' I I C n O SEE RUN"0" (V J .I , I 1 V MS J88 2" 85'-0" MS MIC (/ ) TOSHIBA B"W X 3"H GROMMETED OPENING IN WALL DUCT"WD1". Lu I ITR� DETAIL t E4 LMM 3 J SEE RUN"J" `i 111111 t�4 JB6 J81 2 1J2" 60'-0" CCB CAS TOSHIBA 6"W X 6"H X 4" D J-80X, FLUSH MOUNTED IN FINISHED WALL. FOR CUSTOMER SUPPLIED C 0 DETAIL N 'K' PHY7 PHYSIO EQUIPMENT IN CONTROL ROOM.VERIFY CONNECTIONS/POWER W/MANUFACTURER. G EQUIPMENT LOSE I I J \\\ 1 Ht2428 I I JB6. JB7 (3) 2 1/2" 60,-0" CCB DFP .SEE RUN "K" TOSHIBA 18"W X 6'H X 4"O J-BOX, FLUSH.MOUNTED IN FINISHED FLOOR. FOR CUSTOMER( 1' DETAIL(1/E4)PER ER SUPPLIED PHYSIO EQUIPMENT AT TABLE.VERIFY CONNECTIONS/POWER W/MANUFACTURER. 00 STORAGE it l - Ofi HY JB1 MANUFACTURER MANUFACTURER HY OFP MANUF CONTRACTOR ,. CUSTOMER SUPPLIED PHYSIO MONITOR ON MONITOR SUSPENSION. ACTURER _ I VERIFY CONNECTIONS/POWER W/MANUFACTURER. 1 JL St Luke S 1 O7 HY MS PER PER PER ,r MANUFACTURER MANUFACTURER HY � MANUFACTURER CONTRACTOR J81 16"W% 16"L X 8"D J-BOX,FLUSH MOUNTED IN FINISHED CEILING. CONNECTED TO 4 � r Heallh System BINET VIA 6" �} MANUFACTURER MANUFACTURER MANUFACTURER J82 16 CABS" X B'8L XG6END J ABOXMOUNTED UNDER FLOOR FLEX WRH HOSE, 6"CORE DRILL THRU FLOOR. I"I # 15-310 tr✓ WL JB7 PER PR WL DFP PER CONTRACTOR 4 ES JBS 72"W X 12'H X e'D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 5 PROJECT DATE NOT1U 29 1/2`A.F.F.TO BOTTOM OF BOX. OPEN TO "PCDU". E3 428042.W.09 05.29.2015 J /4 7lNDUITS SUPPLIED/INSTALLED BY CUSTOMER/LONTRALTOR. B. ALL CONDUIT RUNS MUST TAKE THE SHORTEST MOST DIRECT ROUTE POSSIBLE. 10"W X 10'H X 4"D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 24"AF.F, DRAWN CHECKED C. CONDUIT IS NOT TO BE RUN IN SUCH A MANNER THAT WILL EXCEED CONDUIT MAXIMUM LENGTH J84 70 BOTTOM OF BOX, CLC CJW AS SHOWN IN THE SCHEDULES. D. CONSULT WITH TOSHIBA INSTALLATION PROJECT MANAGER IF CONDUIT WILL BE REQUIRED TO BE RUN IN SUCK A MANNER THAT WILL EXCEED MAXIMUM CONDUIT LENGTH SHOWN ABOVE. 8"W X B"H%.4" D J-BOX,FLUSH MOUNTED IN FINISHED WALL. MOUNTED 24"A.F.F. TO JBS BOTTOM OF BOX.FOR CUSTOMER SUPPLIED VIDEO SIGNALS TO WALL. MONITOR. RENSED E. CONDUITS SHOWN FOR"PHYSIO^ARE OPTIONAL AND MAY NOT BE REQUIRED FOR ALL SITES. 8A VERIFY WITH TOSHIBA INSTALLATION PROJECT MANAGER. 16"W X 16'H X 4"O J-BOX,FLUSH MOUNTED IN FINISHED WALL, MOUNTED 9"A.F.F. TO 3 EARTH,ENSURE GROUND TEMPERATURE Does NOT DROP BELOW 4D'F F. CONDUITS BETWEEN C-ARMS AND COOLING UNITS(CONDUITS 10 A 11)CANNOT BE RUN IN AREAS JB6 BOTTOM OF BOX. OPEN TO 'WD3". E3 WHERE THE TEMPERATURE DROPS BELOW 40'F.IF CONDUITS ARE RUN BENEATH SLAB OR IN . �X('T1�� 1IGV ELECTRICAL OUTLETS FOR SYSTEM EQUIPMENT AND/DR SERVICE EQUIPMENT.OUTLETS G. CONDUITS MARKED WITH AN^•^REQUIRE EXTENDED CABLES(SEE DETAIL 1,SHEET EQ. `I- f TO BE LOCATED IN EACH ROOM WHERE SYSTEM EQUIPMENT IS LOCATED, FINAL LENGTH OF CONDUIT TO BE DETERMINED IN FIELD BY I.P.M. -- If RJ45 CONNECTOR; CATS CABLE TO BE USED FOR DATA CONNECTION FOR NETWORKING. If i DEDICATED PHONE LINE SUPPLIED/INSTALLED BY CUSTOMER/CONTRACTOR. i F T ELECTRICAL DUCT LEGEND IN ITEM ITEM DESCRIPTION AN G 1 O LAB CEILING CONDUIT PLAN SUPPLIED AND INSTALLED BY CUSTOMER/CONTRACTOR PEP- F 18 W X 3 1/2"D FLUSH/SURFACE MOUNTED WALL DUCT,W/(3)EQUALLY PARTITIONED SHEET TIRE 1/4"=1'-O" WD7 COMPARTMENTS THROUGHOUT& REMOVABLE ACCESS COVER$. MOUNTED 12'A.F.F.TO J BOTTOM OF DUCT. � ° ANGIO 10"W X 3 1/2"D FLUSH/SURFACE MOUNTED WALL DUCT,W/(3) EQUALLY PARTITIONED F LAB CEILING WD2 COMPARTMENTS THROUGHOUT&REMOVABLE ACCESS COVERS. MOUNTED 12"A.F.F.TO BOTTOM OF DUCT. 1 CONDUIT 10"W X 3 1/2"0 FLUSH/SURFACE MOUNTED WALL DUCT,W/(3) EQUALLY PARTITIONED WD3 COMPARTMENTS THROUGHOUT&REMOVABLE ACCESS COVERS. MOUNTED 12"AYA TO E7 PLAN B BOTTOM OF DUCT. VR 10'IN R 3 1/2"D SURFACE MOUNTED RISER DUCT,W/(3) EQUALLY PARTITIONED COMPARTMENTS THROUGHOUT& REMOVABLE ACCESS COVERS. FROM "PCDU"TO "WD2'. Es SHEET E2-AA ELECTRICAL LEGEND ( \ ITEM\ ITEMDESCRIPTION SUPPLIED AND INSTALLED BY CUSTOMER/CONTRACTOR REF. MAIN MAIN SERVICE ENTRANCE PANEL E+3 p Sryd�5 Qn i CB THREE PHASE CIRCUIT BREAKER PER TOSHIRA POWER SPECIFICATIONS(SEE DETAIL) CIRCUIT +&e BREAKER LOCATION PER CODE REQUIREMENTS BY ELECTRICAL.CONTRACTOR.COS MOZ o CD 18"W X 12"H X 6"D J-BOX, SURFACE MOUNTED 29 1/2"A.F.F.TO BOTTOM OF BOX, 5 ti4r OPEN TO'VR", SEE TOSHIBA'S POWER QUALITY REQUIREMENTS FOR THE GENERATOR. 4 1 TOSHIBA INFINIX SELECT NOTES: EP0 4"STD.J-BOX FOR REMOTE OFF SWITCH. LOCATED BY CUSTOMER/CONTRACTOR. ' DPDT,NORMALLY OPEN MUSHROOM HEAD PUSH BUTTON. E3 E1. GENERAL NOTE: TOSHIBA INFINIX ANGIO LAB COMPONENT DESIGNATIONS ARE AS 4"STD.J-BOX FOR"X-RAY ON"OR WARNING LIGHT MOUNTED ABOVE PATIENT ENTRY 2 FOLLOWS;ALSO REFER TO TOSHIBA DRAWINGS TO DETERMINENERIFY ALL WL DOOR. E3 1 INSTALLATIION REQUIREMENTS;AND FOR CATALOG NUMBER RECOMMENDATIONS e FOR COMPONENTS TO BE PROVIDED BY CONTRACTOR: BS BUILDING STEEL. •1 CONTROL OM 'CONS', E3 'CC ' 98 24"W X 24"L X 18"D J-BOX, MOUNTED UNDER FLOOR WITH B"CORE DRILL THRU +-2 1 HY1' FLOOR.J-BOX TO HAVE REMOVABLE ACCESS COVER. SS •1 'INJC', CAT 1 I 10"W X 10"L X 6"D J-BOX,MOUNTED UNDER FLOOR WITH J"CORE DRILL THRU FLOOR. 3 JR' 'MI ' 1 s� ANGIO LAB MS 10"W X 10"L X 6"D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. w 1 H7242 e O r CCB �co J B DQ o SHARED B"W X 3"H GROMMETED OPENING IN WALL DUCT "WD3". ON E3 r- 0 r M 0 1 0 xmL9 'PHY', © D M p a Lo 'I NJ' AWS 8"W X 3"H GROMMETED OPENING IN WALL DUCT"WD3'. O � maim W - 1 00 u' �( wcu Q a 00 DUAL PLANE LAB SHARED 8 W X 3"H GROMMETED OPENING IN WALL DUCT"Wpt". 3 H7241 AIN4{it 1 J CC J ®® ?v FLOOR CONDUIT SCHEDULE Rao e" 3 = Q E 1 N. W X 3'H GROMMETED OPENING IN WALL DUCT"WDt". E3 ( LL `..�- ' T BBD --i -CONTRACTOR CONDUIT REFERENCE CABLE REFERENCE HIV LOCATED ON SHELF. ` Z '= RUN CONDUIT CONDUIT CONDUIT CABLE CABLE LENOTH CABLES CONTROL ROOM / ® NO. (POINTTOPOINT) (DIAMETER) (MAXLENGTN) (POINT TO POINT) (USABLE) (SUPPLIED BV) %TP GROMMETED OPENING AT END OF WALL DUCT, "WD1"AND "WD2". OPEN TO XYP-810OG GENERATOR CABINETS. J 7 H72418 SEE RUN"A" F JJ- '1 88 PC DETAIL(1/E4) TOSHIBA 8CONNECTS TO "PHY2". u)LLI - O BB JB2 (2),4 45'-0" �BBtD Cq5 SEE RUN "B" TOSHIBA COMBINED ``�`JJ DETAIL(1/E4) INJC ' Q O � ► � 1 , U O SEE RUN "C" SHARED 8'W X 3"H GROMMETED OPENING IN "WD3". e3 e ,1 8 pFP DETAIL(1/Ei) TOSHIBA INJR O 1 I 10 88 JB4 2 1/2" 6W-0' BB WCU SEE RUN "0"DETAIL(1/E4) TOSHIBA 11"W.X 8"L X 5" D, STEP-DOWN TRANSFORMER,TO BE LOCATED.ON SHELF TRS INV (BY CUSTOMER/CONTRACTOR)ABOVE 'PCDU°AS LONG AS LOCAL CODE ALLOWS, a LLI 'PCCI SEE RUN "E" Z Z " 1 11 2 1/2" 85'-0' 88 CC DETAIL(1/E4). TOSHIBA MIC 8"W X 3"H GROMMETED OPENING IN WALL DUCT"W03". E3: N _i ,1 LLI 1 12 HY JB6 2" 48'-0" s INJ INJR PER CONTRACTOR , > J ' MANUFACTURER LMM 8'W X 3"H GROMMETED OPENING IN WALL DUCT"WD1'. E3 1 EQUIPME CLOSE SEE RUN `G 2 d'1 13 CAT JB6 2" 48'-0" CAT CCB TOSHIBA 6"W X 8"H X 4" D J-80X, FLUSH MOUNTED IN FINISHED WALL. FOR CUSTOMER SUPPLIED J H124 I CO 8 O DETAIL(1/E4) HY PHYSIO EQUIPMENT IN CONTROL ROOM.VERIFY CONNECTIONS/POWER W/MANUFACTURER. �/� 1 .. SEE RUN'G" V J CO O 5' 14 CAT (JJB6 2 1/2" 48'-0` CAT CCB TOSHIBA t8"W X 6 H X 4 D J BOX, FLUSH MOUNTED IN FINISHED FLOOR. FOR CUSTOMER 1 -- O L,J O DETAIL(T/B4) HY SUPPLIED PHYSIO EQUIPMENT AT TABLE.VERIFY CONNECTIONS/POWER W/MANUFACTURER. STORAGE �, ,,",."z�=�` H+z4+c O SEE RUN "H" ALL St Luke's 0 1 15 CAT JB2 2"& 2 1/2" 50'-0" CAT DFP DETAIL N "H' TOSHIBA �, CUSTOMER SUPPLIED PHYSIC MONITOR ON MONITOR SUSPENSION, ..I L VERIFY CONNECTIONS/POWER W/MANUFACTURER r HeaRh System i6 CAT. JB2 2 1/2" 48'-0` CAT CAS SEE RUN 'I" TOSHIBA 16"W X 16`L X 8"D J-BOX, FLUSH MOUNTED IN FINISHED CEILING.CONNECTED TO e4 I # 15-310 DETAIL(1/E4) J81 "CABS"XTP-81COG END CABINET VIA 6"CONDUIT OR FLEX HOSE. PER PER PER 17 PHY HY MANUFACTURER]MANUFACTURER HYi HY MANUFACTURER CONTRACTOR JB2 16"W X 16' L X B"D J-BOX, MOUNTED UNDER FLOOR WITH 6"CORE DRILL THRU FLOOR. E, PROJECT DATE 42BD42.MV.09 05.29.2015 9 JB3 29Y /2' A F.FH TO BOTTOM OF HBO FLUSH OPEN TOTEPCOUD IN WISHED WALL, MOUNTED E} 1 DRAWN CHECKED CLC CJW JB4. 10°W X 10"H X 4"0 J-BOX, FLUSHMOUNTED IN FINISHED WALL, MOUNTED 24`A.F.F. TO BOTTOM OF 80%. REVISED ES) W X 8"H X 4'D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 24"A.F.F.TO ES) BOTTOM OF BOX.FOR CUSTOMER SUPPLIED VIDEO SIGNALS TO 58"MONITOR. .JB6 16"INBOTTO XO1 BOX.XOPEN TO"WD3"FLUSH MOUNTED IN FINISHED WALL,MOUNTED 9"A.F.F. TO E3 ,,fi1tn� 11 OV ELECTRICAL OUTLETS FOR SYSTEM EQUIPMENT AND/OR SERVICE EQUIPMENT, OUTLETS TO BE LOCATED IN EACH ROOM WHERE SYSTEM EQUIPMENT 1S LOCATED. RJ45 CONNECTOR, CATS CABLE TO BE USED FOR DATA CONNECTION FOR NETWORKING. m !11 DEDICATED PHONE LINE SUPPLIED/INSTALLED BY CUSTOMER/CONTRACTOR. X A' P FI N ELECTRICAL DUCT LEGEND �ANG10 LAB FLOOR CONDUIT PLAN ITEM SI ITEM DESCRIPTION 1/4"=1'_0" SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR REF. PI SHEETTI E 18"W X 3 1/2"0 FLUSH/SURFACE MOUNTED WALL DUCT, W/(3) EQUALLY PARTITIONED , ANGIO WD1 COMPARTMENTS THROUGHOUT&REMOVABLE ACCESS COVERS, MOUNTED 12"A.F.F,TO E3 SI BOTTOM OF DUCT, LAB FLOOR 10"W X 3 1/2"D FLUSH/SURFACE MOUNTED WALL DUCT,W/(3) EQUALLY PARTITIONED WD2 COMPARTMENTS THROUGHOUT&REMOVABLE ACCESS COVERS. MOUNTED 12"A.F.F. TO PI CONDUIT BOTTOM OF DUCT. 1: PLAN 10"W X 3 I/2"D FLUSH/SURFACE MOUNTED WALL DUCT,W/(3) EQUALLY PARTITIONED , W03 COMPARTMENTS THROUGHOUT&REMOVABLE ACCESS COVERS,MOUNTED 12"A.F.F.TO E, BOTTOM OF DUCT, 10"W X 3 1/2"D SURFACE MOUNTED RISER DUCT,W/(3) EQUALLY PARTITIONED a SHEET VR COMPARTMENTS THROUGHOUT& REMOVABLE ACCESS COVERS. FROM "PCDU"TO "W02", E3 ELECTRICAL LEGEND ITEM ITEM DESCRIPTION CEILING CONDUIT SCHEDULE SUPPLIED AND INSTALLED BY CUSTOMER/CONTRACTOR REF" \ MAIN MAIN SERVICE ENTRANCE PANEL 1 CONTRACTOR CONDUIT REFERENCE CABLE REFERENCE E3 � StydA) II RUN CONDUIT CONDUIT CONDUIT CABLE CABLE LENOTH CABLES CB THREE PHASE CIRCUIT BREAKER PER TOSHIBA POWER SPECIFICATIONS (SEE DETAIL) CIRCUIT 1&s �yd NO. (POINT TO POINT) (DIAMETER) (MAX LENGTH) (POINT TO POINT) (USABLE) (SUPPLIED er) BREAKER LOCATION PER CODE REQUIREMENTS BY ELECTRICAL CONTRACTOR. O7 JB3 MS PER CODE PER CODE CD MS) PER CODE CONTRACTOR CD 1B" W X 12" H X 6" D J—BOX, SURFACE MOUNTED 29 1/2" A.F.F. TO BOTTOM OF BOX. SEE RUN "A" OPEN TO 'VR1". SEE TOSHIBA'S POWER QUALITY REQUIREMENTS FOR THE GENERATOR. \y E3 rW 1 oa 83 PC1 To5HIBA EPO 4" STD. J—BOX FOR REMOTE OFF SWITCH. LOCATED BY CUSTOMER/CONTRACTOR.DETAIL(1/E4) O I DPDT, NORMALLY OPEN MUSHROOM HEAD PUSH BUTTON. E3 SEE RUN "B" 83 CA51 DETAIL(1/E4) TOSHIBA 4" STD. J-BOX FOR "X-RAY ON" OR WARNING LIGHT MOUNTED ABOVE PATIENT ENTRY 2 r1 O2 83 JB1 COMB 36'-D" WL DOOR. INED E3 SEE RUN "C" 83 CAS TOSHIBA O DETAIL (1/E4) 1 BS BUILDING STEEL. E3 1 CONTROL OM SEE RUN DFP lI H1 83 DETAIL(1/E4) TOSHIBA 12" W X 12" L X 6" D J-BOX, MOUNTED UNDER FLOOR WITH 6" CORE DRILL THRU FLOOR. 1-2 3 83 JB4 2 1/2" 60'-0" 83 CU SEE RUN "E" TOSHIBA J-BOX TO HAVE REMOVABLE ACCESS COVER. 53 II O O O O O DETAIL(1/E4) C81 e 1 SEE RUN "F" C83 8" W X 16" L X 8" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. 4 •J�. CU1' O4 83 JB4 2 1/2" 60'-0" 83 CC1 E3 n I DETAIL(1/E4) TOSHIBA 1 O5 MS JB1 (2) 2" 75'-0" MS DFP SEE RUN CAT TOSHIBA 10" W X 10" L X 6" D J-BOX, MOUNTED UNDER FLOOR WITH 7" CORE DRILL THRU FLOOR. S3 r CC _ o Og I 1 O O O O DETAIL (1/E4) 0000CJ SEE RUN "AA" MS 10" W X 10" L X 6" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. E3 �rM ® EOUIPMEN ROOM - 6 MS JB7 2" 80'-0" MS MIC TOSHIBA 11 H1241A 'JBS', I S2 O O O O O DETAIL(1/E4) O O cc Lc) 'WCU2', @ry1, 11 I'IJ u'i I O O O MANUFACTURER O O MANUFACTURER PER PER O o yM ' CO CC2' 7 JB6 JB1 2" JB6 DFP CONTRACTOR CCB M m DO SEE RUN "Q" ON SHARED 8" W X 3" H GROMMETED OPENING IN WALL DUCT '1ND2". 3 I [LmN CCB CAS TOSHIBA 0 _ 1 1 DETAIL SEE RUN(1/E4)"R" � O8 JB7 J81 2 i/2" 65'-0" vv z' J DUAL PLANE A0 I CCB CAS DETAIL (1/E4) TOSHIBA AWS J J •-" I _ 5 SEE RUN "S" O9 JB7 J81 (3) 2 1/2" 65'-0" CCB DFP DETAIL(1/E4) TOSHIBA 3 M� LL N INJC SHARED 8" W X 3" H GROMMETED OPENING IN "WD2". E3 W Z PER PER HY DFP PER CONTRACTOR MANUFACTURER MANUFACTURER O O MANUFACTURER R O O O PER PER O O PER INJR J 1 .� 11 HY MS PHY1 HY I CONTROL ROOM MANUFACTURER MANUFACTURER MANUFACTURER �- I I I .... 12 CONTRACTOR NJ H1241B CONNECTS TO "PHY2" C JB3 RSL PER CODE PER CODE CD RSL PER CODE CONTRACTOR = W 1 > ' v 1 13 WL JB1 PER PER O O PER. CU MANUFACTURER MANUFACTURER WL DFP MANUFACTURER C R O CB, ,1 SHARED 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD2". 3 Q CC1 E3 'MIC' 1 U_ CONI$' 1 NOTE: OQ A. CONDUITS SUPPLIEDANSTALLED BY CUSTOMEWCONTRACTOR. O �_ B. ALL CONDUIT RUNS MUST TAKE THE SHORTEST MOST DIRECT ROUTE POSSIBLE. CU W C. CONDUIT IS NOT TO BE RUN IN SUCH A MANNER THAT WILL EXCEED CONDUIT MAXIMUM LENGTH 7 Z 1 AS SHOWN IN THE SCHEDULES. SHARED 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD2 E3 ^L' ` �2 1 D. CONSULT WITH TOSHIBA INSTALLATION PROJECT MANAGER IF CONDUIT WILL BE REQUIRED TO BE CC2 `V J 1 RUN IN SUCH A MANNER THAT WILL EXCEED MAXIMUM CONDUIT LENGTH SHOWN ABOVI W E. CONDUITS SHOWN FOR"PHYSIO'ARE OPTIONAL AND MAY NOT BE REQUIRED FOR ALL SITES. J VERIFY WITH TOSHIBA INSTALLATION PROJECT MANAGER. J F. CONDUITS BETWEEN C-ARMS AND COOLING UNITS(CONDUITS S&4)CANNOT BE RUN IN AREAS RAID 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD2". E3 C>C 0 WHERE THE TEMPERATURE DROPS BELOW 407.IF CONDUITS ARE RUN BENEATH SLAB OR IN G '1 EARTH,ENSURE GROUND TEMPERATURE DOES NOT DROP BELOW 4WF. INV LOCATED ON SHELF. J T 0. CONDUITS MARKED WITH AN—REQUIRED EXTENDED CABLES(SEE DETAIL 1.SHEET 194). � CO 1 O FINAL LENGTH OF CONDUIT TO BE DETERMINED IN FIELD BY I.P.M. '' 'C 30' STp�GE I.1 XTP GROMMETED OPENINGS IN "VR2". OPEN TO XTP-810OG GENERATOR CABINETS. AL St Luke's TRS 11" W X 8" L X 5" D, STEP—DOWN TRANSFORMER, TO BE LOCATED ON SHELF 1 r Health System (BY CUSTOMER/CONTRACTOR) ABOVE "PCDU" AS LONG AS LOCAL CODE ALLOWS. 'I # 15-310 _ MIC 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD2". 3 ' E3 PROJECT DATE I LMM 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD1". 3 428042.W.09 0529.2015 TOSHIBA INFINIX SELECT NOTES: E3 DRAWN CHECKED CLC CIW E1. GENERAL NOTE: TOSHIBA INFINIX DUAL PLANE COMPONENT DESIGNATIONS ARE AS RSL 6" W X 6" L X 4" D J—BOX, FLUSH MOUNTED IN FINISHED CEILING. E3 - FOLLOWS;ALSO REFER TO TOSHIBA DRAWINGS TO DETERMINEIVERIFY ALL REVISED INSTALLATHON REQUIREMENTS;AND FOR CATALOG NUMBER RECOMMENDATIONS PHYi 6" W X 6" H X 4" D J—BOX, FLUSH MOUNTED IN FINISHED WALL. FOR CUSTOMER SUPPLIED 8A FOR COMPONENTS TO BE PROVIDED BY CONTRACTOR: PHYSIO EQUIPMENT IN CONTROL ROOM. VERIFY CONNECTIONS/POWER W/MANUFACTURER, HY 18 W X 6" H X 4" D J—BOX, FLUSH MOUNTED IN FINISHED FLOOR. FOR CUSTOMER SUPPLIED PHYSIO EQUIPMENT AT TABLE. VERIFY CONNECTIONS/POWER W/MANUFACTURER. \ CUSTOMER SUPPLIED PHYSIO MONITOR ON MONITOR SUSPENSION. HY VERIFY CONNECTIONS/POWER W/MANUFACTURER. 7A 6A 16 W X 16" L X 8" D J—BOX, FLUSH MOUNTED IN FINISHED CEILING. CONNECTED TO 4 JBi "CABS" XTP-810OG END CABINET VIA 6" CONDUIT OR FLEX HOSE. E3 JB2 16" W X 16" L X 6" D J-BOX, MOUNTED UNDER FLOOR WITH 6" CORE DRILL THRU FLOOR. 4 JB3 12" W X 12" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 5 29 1/2" A.F.F. TO BOTTOM OF BOX. OPEN TO "PCDU". E3 JB4 10" W X 10" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 24" A.F.F. ' TO BOTTOM OF BOX. JB5 10" W X 10" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 24" A.F.F. SHEETiTILE TO BOTTOM OF BOX. N JB6 8" W X 8" L X 4" D J—BOX, FLUSH MOUNT IN FINISHED CEILING. FOR CUSTOMER + DUAL PLANE DUAL PLANE LAB CEILING CONDUIT PLAN SUPPLIED VIDEO SIGNALS TO 58" MONITOR. E3 CEILING 1/4"=1'-0" JB7 16" W X 16" H X 4" D J—BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 9" A.F.F. TO 3 CONDUIT T7 BOTTOM OF BOX. OPEN TO "WD2". E3 4i TO BEELOCATEDLIN UEA HSROOM WHERE SYSTEM EEQUIPMENT ISELOCATED.VICE EQUIPMENT. OUTLETS PLAN ® RJ45 CONNECTOR, CAT5 CABLE TO BE USED FOR DATA CONNECTION FOR NETWORKING. UD SHEET ® RJ47 CONNECTOR, CAT7 CABLE TO BE USED FOR DATA CONNECTION FOR NETWORKING. Q ® DEDICATED PHONE LINE SUPPLIED/INSTALLED BY CUSTOMER/CONTRACTOR. E 2■1 1 I TOSHIBA INFINIX SELECT NOTES: El. GENERAL NOTE: TOSHIBA INFINIX DUAL PLANE COMPONENT DESIGNATIONS ARE AS ELECTRICAL LEGEND FOLLOWS;ALSO REFER TO TOSHIBA DRAWINGS TO DETERMINE/VERIFY ALL ITEM DESCRIPTION INSTALLATIION REQUIREMENTS;AND FOR CATALOG NUMBER RECOMMENDATIONS ITEM SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR REF. 1 MGR OFFICE, -I FOR COMPONENTS TO BE PROVIDED BY CONTRACTOR: 9 MAIN MAIN SERVICE ENTRANCE PANEL 1 � E3 '1 _� R Sryyr ') _ CB THREE PHASE CIRCUIT BREAKER PER TOSHIBA POWER SPECIFICATIONS (SEE DETAIL) CIRCUIT I&6 Q BREAKER LOCATION PER CODE REQUIREMENTS BY ELECTRICAL CONTRACTOR. E3 �ydo ; 1 ! 1 CD 18 W X 12" H X 6" D J-BOX, SURFACE MOUNTED 29 1/2" A.F.F. TO BOTTOM OF BOX. z w MN o s •1 I �- •1. FLOOR CONDUIT SCHEDULE OPEN TO "VR1". SEE TOSHISA'S POWER QUALITY REQUIREMENTS FOR THE GENERATOR. E3 1'1 a EPO 4" STD. R BOX FOR REMOTE OFF SWITCH. LOCATED BY CUSTOMER/CONTRACTOR. �S HA I CONTRACTOR CONDUIT REFERENCE C Hi 1 CABLE REFERENCE DPpT, NORMALLY OPEN MUSHROOM HEAD PUSH BUTTON. E3 1 I PCDU', 1 RUN CONDUIT CONDUIT CONDUR CABLe CABLELENOTN IABLEB 4" STD. J-BOX FOR "X-RAY ON" OR WARNING LIGHT MOUNTED ABOVE PATIENT ENTRY 1 VIRVTIRS, i I NO, (POINT TO POIN ) (POINT TO POINT) (USABLE) (SUPPLIED Ell) WL DOOR. E3 'VR1' "•- —�— T) (DIAMETER) (MA%LEN6711 I J 3' ' I -- C81 PC2 SEE RUN "H" TOSHIBA W 1, /,.� ID' ,_� _�' O DETAIL(1/E4) BS BUILDING STEEL. E3 n. r CONTROL ROOM 14 81 JB2 (2)4" 55'-0" 51 CAS SEE RUN"I" TOSHIBA ?OE.B ) � 1 N1242A O O COMBINED DETAIL(1/E4) 12" W X 12" L X 6" D J-BOX, MOUNTED UNDER FLOOR WITH 6" CORE DRILL THRU FLOOR. CUT', SEE RUN"J" 6 81 J-BOX TO HAVE REMOVABLE ACCESS COVER. s3 XTP;, J 8C411 II 81 DFP DETAIL(1/E4) TOSHIBA 4 2 1/2' 70'-0" SEE RUN TOSHIBA C83 8" W X 16" L X 8" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. aE3 �- •1 .- 1 81 JB5 81 CU DETAIL(1/E4) 20F �' I i 'UM 1 SEE RUN "L"'I 1I 16 81 JB5 2 1/2" 70'-0" at CC2 DETAIL(1/E4) TOSHIBA CAT 10" W X 10" L X 6" 0 J-BOX, MOUNTED UNDER FLOOR WITH 7" CORE DRILL THRU FLOOR. s3 p _ 1• 17 CAT JB7 2 1/2' 28'-0" CAT CCB SEE RUN "M" TOSHIBA 00� 11, CD EQUIPMENT ROOM 'NV'r s2 O O O O DETAIL(1/E4) MS 10" W X 10" L X 6" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. r4 v 0 'JB5' I SEE RUN '0' E3 � f r_L M 1 1 H1241A 'WCU2', CAT CASs DETAIL(1/E4) TOSHIBA W Mln X '1 1 'CC2' 18 CAT JB2 COMBINED 45'-0" CCB CD p ��� SEE RUN E4 SHARED 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD2". 1 I CAT TOSHIBA e3 O m O)M 1 DETAIL(1/E4) E3 d 1 DO 1 SEE RUN "N" ON Q 0_0Cv I, 19 CAT Jag 2"&2 i/2" 49'-0" CAT DFP TOSHIBA ' I D DETAIL(1/E4) DUAL HILANELAB II 20 HY PER PER HY HY PER CONTRACTOR AWS MANUFACTURER MANUFACTURER MANUFACTURER J 21 HY JB7 2" INJ INJR PER CONTRACTOR Q VB' O MANUFACTURER O O MANUFACTURER INJC 5HARED 8" W X 3" H GROMMETED OPENING IN "WD2". Es m —i 22 CAT JB7 2" 42'-0^ 11 CAT CCB SEE RUN -M" TOSHIBA Z 'INHY2', 1 DETAIL(1/E4) INJRLUj 1 NOTE: Q '1 ® ®� 'IN 'CONTROLROQM / A. CONDUITS SUPPLIEDIINSTALLEDBYCUSTOMERICONTRACTOR. INJ CONNECTS TO "PHY2". ,J 'INJ H1241B -� B, ALL CONDUIT RUNS MUST TAKE THE SHORTEST MOST DIRECT ROUTE POSSIBLE. CONDUIT IS NOT TO BE RUN IN SUCH A MANNER THAT WILL EXCEED CONDUIT MAXIMUM LENGTH w 1 I AS SHOWN IN THE SCHEDULES. CU D. CONSULT WITH TOSHIBA INSTALLATION PROJECT MANAGER IF CONDUIT WILL BE REQUIRED TO BE � j RUN IN SUCH A MANNER THAT WILL EXCEED MAXIMUM CONDUIT LENGTH SHOWN ABOVE. SHARED $" W X 3" H GROMMETED OPENING N WALL DUCT "WD2". 3 a: : A CCB' 1 E. CONDUITS SHOWN FOR"PHYSIO"ARE OPTIONAL AND MAY NOT BE REQUIRED FOR ALL SITES. E3 Q ICE/' VERIFY WITH TOSHIBA INSTALLATION PROJECT MANAGER. C(,'1 _ LQ I OtfS' I F. CONDUITS BETWEEN C-ARMS AND COOLING UNITS(CONDUITS 15 A 16)CANNOT BE RUN IN AREAS WHERE THE TEMPERATURE DROPS BELOW 40•F.IF CONDUITS ARE RUN BENEATH SLAB OR IN O EARTH,ENSURE GROUND TEMPERATURE DOES NOT DROP BELOW 40•F. OU Q N Y1, ( G. CONDUITS MARKED WITH AN"""REQUIRED EXTENDED CABLES(SEE DETAIL 1,SHEET E4). LL _ ® SHARED 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD2"• 3 W FINAL LENOTN OF CONDUIT TO BE DETERMINED IN FIELD I I.P.M. E3 Z 75 CC2 N 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD2 3 UJI E3 5 G I INV LOCATED ON SHELF. r- 20G � �~ XTP .8STORAGE I GROMMETED OPENINGS IN "VR2". OPEN TO XTP-810OG GENERATOR CABINETS. vJ H1241C I 11" W X 8" L X 5" D, STEP-DOWN TRANSFORMER, TO BE LOCATED ON SHELF ,JrGalthSphomL St Luke's i I, TRS (BY CUSTOMER/CONTRACTOR) ABOVE "PCDU" AS LONG AS LOCAL CODE ALLOWS. , '-'' #SIC SW X 3" H GROMMETED OPENING IN WALL DUCT "WD2". 3 15-310 E3 PROJECT DATE 1' 1 LIAM 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD1". 3 429042.W.09 0529.2015 '1 I 1 E3 DRAWN CRIME) 1I RSL 6" W X 6" L X 4" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. 4 CLC CJW 1 1 1 E3 PHY1 6" W X 6" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL. FOR CUSTOMER SUPPLIED REVBED 1 (RA 1 PHYSIO EQUIPMENT IN CONTROL ROOM. VERIFY CONNECTIONS/POWER W/MANUFACTURER. 1 1'l �J HY FLUSH SUPPLIED PHYSIO EQUIPMENTT AT TABLE.M FINISHED CUSTOMER VERIFY CONNECTIONS/POWER CTIONS/POWER W/MANUAOTURER. ,I 1 HY CUSTOMER SUPPLIED PHYSIO MONITOR ON MONITOR SUSPENSION. VERIFY CONNECTIONS/POWER W/MANUFACTURER. 7A JB1 16" W X 16" L X 8" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. CONNECTED TO 4 8A "CABS" XTP-810OG END CABINET VIA 6" CONDUIT OR FLEX HOSE. E3 JB2 16" W X 16" L X 6" D J-BOX, MOUNTED UNDER FLOOR WITH 6" CORE DRILL THRU FLOOR. 4 E3 JB3 12" W X 12" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 5 29 1/2"A.F.F. TO BOTTOM OF BOX. OPEN TO "PCDU". E3 JB4 10" W X 10" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 24" A.F.F. TO BOTTOM OF BOX. J85 10" W X 10" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 24" A.F.F. i B05TO BOTTOM OF BOX. 81EEf TIRE JB6 8" W X 8" L X 4" D J-BOX, FLUSH MOUNT IN FINISHED CEILING. FOR CUSTOMER 4 DUAL PLANE SUPPLIED VIDEO SIGNALS TO 58" MONITOR. E3 JB7 16" W X 16" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 9"A.F.F. TO 3 FLOOR A�, BOTTOM OF BOX. OPEN TO "WD2". E3 CONDUIT TO BE LOC110 ATIEDLI OUTLETS WHERE SYFOR SYSTEM STEMEEQUIPMNT ENT ISELOCATEDQUIPMENT. OUTLETS PLAN DUAL PLANE LAB FLOOR CONDUIT PLAN RJ45 CONNECTOR, CAT5 CABLE TO BE USED FOR DATA CONNECTION FOR NETWORKING. 1/4"=1'-0" ® RJ47 CONNIECTOR, CAT7 CABLE TO BE USED FOR DATA CONNECTION FOR NETWORKING. SHEET B7 2 Q ® DEDICATED PHONE LINE SUPPLIED/INSTALLED BY CUSTOMER/CONTRACTOR. T �E2:22 \, �. ,\ /':l FD! fC•,�.'� f0 11 �,91 19 lyl _=_-- \•\ •\ Es, � �` •\ \ I �,\ I I I I I I I I I I � I OT N.- z w ��2= Ij - - - ------- - - - - - - - I------•I------- �----- ® \'! /\\ I I I FROM AT5 BLLADP(H1) I /� � ,.�\•�I� I I I I I (3)3"SPARE FROM O \I I I R28 BNHBSWBD - .-- 1 - _. - - ',-•''� -� I I I I X-BLLBD Q ' I CONDUIT TEDCKfNG�IlFlIROU ESECTRICAL i BASEMENT FLOOR PLAN BNLB�P H1, BNLC_OP�N2)_ S p I I I NOTES P14,P27-''y — H04 UrUR"PgNEL p j - - ITH OTHER TRADES; M COORDINATE V� SEE THIS SHEEt DETAIL 2. j j BNLCDP(H2) H0488 ��o j II------------ -- ---- --- ---------- - - fC�MfH� p ��-- -- --- ---- --- n EO i i j T 'EH25 v UTUR�pgNS CD O � [°Nm TX-BNLADP(_H1 TX-BNLBDP(H1 L I j I I ) ) TX-B LCDP H2 rn d ro N o BCLH H1 fn j mn I PANELBCLAHDP(Hl), `' J J I I WHICH-IS AN-EATON - • PANEL,SHALL BE - .....- -- - - - - �I ._..,.._------- -- l - . MODIFIED IN THE m � FU7EPIA- kY)N9;MANNER: C�Bp @C Z UTILIZE AVAI IBLE z LAOa H1 m SPARE CIRCUI a Z N - BREAKER m Q 2 V J noJ Z J� T U) 1 LU I 2 UTILIZE SOURCE SIDE > — -- -------•---I -------•------ ---- ---- - - ----- --- m OF ONE CONTROLLED ._ Q Q LIGHTING CIRCUIT «. . U Q FOR AUXILARY POWER, '"^ Q 0 FEEDER TRANSITION a L� Z FROM BASEMENT aF -g zCV J TO 1ST FLOOR w jcLR H1 ENLARGED ELECTRICAL ROOMS - H0488 AND H0476 a p —1 (j) NTS J T I _ r FS E2.3 (n � SUGGESTED CORRIDOR ALL St Luke's r Health System _. ELECTRICAL CONDUIT �r RACKING ROUTES; \ _,,,_,._,N,._... _ uN� COORDINATE WITH "�"EP^"E pore P9 — Dos [ ,lxn, o;'I 1 # 15 310 u _ H!c M OTHER TRADES;SEE PROJECT DATE -_ THIS SHEET DETAIL 1. o-_ER ffi � _ � ullllp ' r aus.�ln \ e 428042.MV.09 0528.2015 �d rf DRAWN CHECKED _ & PuIP cl�� n�,,,,,1 CLC CJW c REVISED c5, - Lao LF � KhR• [-� QINI II' IgItIRI'JIIII ... . d - PANEL BCHQ(Hl),WHICHrT= \ ncu n S - IS AN EATON PANEL,SHALL am om BE MODIFIED IN THE ca m a awm a POSSIBLE FEED Rolx n jA FOLLOWING MANNOR: UTILIZE AVAILABLE cwnloae ® TRANSITION FIR m MD SPARE CIRCUIT na 9� N=was t BASEMF T M U romi BREAKER TO 1STLOOR �,,-w l - 18 c=� 0 Byp Hi E �9 SUGGESTED CORRIDOR 1 H0427 y ELECTRICAL CONDUIT NOT --...- RACKING ROUTES; \ T SHEEP TITLE COORDINATE WITH N wa.oz PAtll xl. OTHER TRADES. \ n BASEMENT & 1ST FLOOR LOCATION >UnREe y PLAN 1ST FLOOR PLAN OVERLAY BASEMENT FLOOR PLAN SHEET N T)3"=11-01.BASEMENT LOCATION PLAN ENLARGED ELECTRICAL ROOM - H0427 �E2:3- L NTS E2.3 ' (eo'a� '\ •\ i I I I I I e SWbi p ^p �\ \' \\ •I .- /\ ! I j I I I I j I z w MN� � El y •" '\ -�' Q - - - F - ------- ---E-•------I---------' -I------- Fl mo•' i ; ffi i I i�+tea L-J oqcDw • ffi m_ 0 es - - - -- - - - -.- - - _. - -_ - — - ��o \I - - - - - .� i H1451 t3 H1452 = � 00 aid dmn co mks .V z i NOTEP20 Q amN U) g NOTE P2,TYP = N 7CLR H1 J J I adr 1 tl z I J - - _ &tt z a A16,EP4, Z a,III P6,EP8 m I 7- v I I =< 7\ l NOTE PB J � W ~H - - - - - - o. _ e a Q i • Q O R1f 10� 75 - ENLARGED ELEC ROOMS - H1451 & H1452 Z z _ _ Ills W i > J I di I I mm I o '' - I .-- . R„ • I " St Luke s •' ..,. � Health System TM # 15-310 IIII AREA OFWOR -- � w a �I °�SEE ARCHITEC i�~ - - - - PROJECT Dare '96P R. m „„. �'j 428042.MV.09 05.29.2015 SUG ESTED C(D RI DO EL CTRI7 U O ffi DRAWN CHECKED --- G R . R - ------�-- _ - -- --- I CONDUIT RACKING ROUTES: ' �• COORDINATE WITH"OTHER TRADES CLC CJVV REVISED (nn ,an I n SHEETTME SUGGESTED CORRIDOR ELECTRICAL 1ST CONDUIT RACKING ROUTES: FLOOR LOCATION COORDINATE WITH OTHER TRADES PLAN N 1ST FLOOR LOCATION PLAN SHEET Y E2:31 LIGHTING PLAN NOTES: (FOR LEGEND AND GENERAL NOTES SEE SHEET E1.0,FOR LOCATION PLAN,SEE SHEET E2.3 AND E2.3.1) L1. GENERAL NOTE: DEVICES SHALL BE CIRCUITED ACCORDING TO THE SCHEDULE AS SHOWN ON THE POWER PLAN,SHEET E2.0. L2. GENERAL NOTE: ELECTRICAL DEMOLITION INCLUDES,BUT IS NOT LIMITED TO SWITCHES,WALL, UNDER CABINET,AND CEILING LIGHTING FIXTURES. (FOR REFERENCE ONLY). L3. GENERAL NOTE:CIRCUIT HOMERUNS/CONDUCTORS MAY BE EXISTING IN THIS SPACE,UNLESS iw OTHERWISE NOTED. EXTEND CONDUCTORS AS REQUIRED TO NEW LIGHTS/CONTROLS AND NEW PANEL LOCATIONS.VERIFY ALL CIRCUIT NUMBERS IN THE FIELD. TYPICAL.L4. GENERAL NOTE: WHERE CIRCUITING LINEWORK AND JUNCTION BOXES ARE NOT SHOWN,PROVIDESIMILAR TO COMPARABLE SPACES. CIRCUIT TO PANEL BOARD AS INDICATED. TYPICAL. L5. CIRCUIT EXIT SIGNS FOR THIS FLOOR TO THE NEAREST LIFE SAFETY(LA,LB) - 1 CIRCUITS.TYPICAL M 1 1 1 It L6. GENERAL NOTE:FISH 3/4"FLEXIBLE CONDUIT FOR RUNS IN EXISTING WALL OR TO NEW OUTLET BOXES MOUNTED IN EXISTING WALL. - L7. GENERAL NOTE:PROVIDE DUAL SWITCH CONTROL FOR TYPE'R'FIXTURES SPECIFIED WITH AND LOCATION NG BALLAST; COORDINATE LIGHTING PLAN WITH LUMINAIRE SCHEDULE FOR QUANTITY 1 I L8. GENERAL NOTE:CONNECT FIXTURE EMERGENCY BATTERY PACK TO HOT LEG OF CIRCUIT FOR THIS SPACE (NOT SWITCH LEG).TYPICAL FOR EMERGENCY BATTERY PACK FIXTURES. 1 _ L9. REFERENCE NOTE: WALL MOUNTED HAND SANITIZERS ARE TO BE MOUNTED A MINIMUM OF V-0" r- ___ CLEAR OF ALL ELECTRICAL SWITCHES AND RECEPTACLES. o •- -- b c d C �p----- a� L10.CLEAN,RELAMP AND RE-INSTALL THIS AREA,TYPICAL. OD coCO o 20E.8 __.__ f ti L - - F` ¢c� 242A - 1 _ I, 'C -Ir � x L tC) :_ ._ ,Y_-----r_�--�--"N6TE L5 ',.__. '1 H� '_-----j- g s•A•F F f -"I- �� �' C.nr�-7��^c,_, (.�.�5 -�'D (9-e.ri•� � M ��v ® , Q�Cszrv�,r�-�- 1 �aim a..----- 1 E 5 lr c t- CO N 00 '1INOTEL1U,-� _- `' �1\I R4 - it --',I- \I Q amc�" � Ly _ N Ly 20F '1 I - a t--- I e- -L, EN16 EQUIPMENT ROOw1 _- 11 11 --`r 1 - -!� „".� �`\ _ '- ILL - _ 1 �+1 H1241A I r \ ® .. 1 ❑ rut acmaenle m1 dwlx wmmle Ilia one. Z _ ffi„�<, ...r I me.rx b a mrtla,.Ralpm.nu.ron rmlm,rodragm.,publb lobby,waml.dl.mom.ordxPlllg umt. `\ .�e-__ , -- I �__ - -_I-- \\ COMcheckSoftwareVersion3.9.2 ❑ In - 1 9'.6 A.F.F. R4 _ �- - =r- _-�- -'--- Interior Lighting ❑ Aroalth-ad 11W.-to.R. ye q mlrc". Q --- g Compliance iance ,,,.__._.. .1'Y. - ® -_ g ❑5.❑Adana°I c'�m•s�°L°wikhklpow,boN reRInWIIN°rM hw°en aveMds ew11cRNB dwla.TM ownitla cwllcNnB aerie elbwa for,-2 G6 --- Certificate hour dma a1NneP•ne<. `I --.-_._.... t , C Wen yde 6000 W.R.,manual Wenlbn,end b roetlly.mxelde entl brats when the aPrel6n pl Ms H SKYRON , 1 cannadetl qhq an vbbbawmmmkegdWNe awildi 12IEC . 1 V : - -CONTROLLER �8 }' C_' ExPepmnra: fn 11 ❑ axpbg uNg4p�bnluro eras end epeoa where eubmetic ahuWRworld«Merger sNdy xardy or whero llBMinpb W - NOTE L101 i b In Wrz. prop•ndan. S - Section 1:Pro a I ® ' Jett Information --:%---. ' I" �I 1 1 1 , ❑ D1largerlry aprese iglMrN. -fi.~- 1 ® 1_ _ _--i Y_ 1 sparewlwroNhdw1.-hosadwnne�.,.yxmmM. Q ENj -I YPe:ANerNlon ❑ WTle 2NO OATH LAB BUILD-OUT ❑ zB.a w n a«mm.e d G6 ' ' Waal BCWr, ❑ B I Pro) ti SLMV LD-OUT M•II•,«catlx,rudlbrWmr,•Ingle bnMl refill rpans,IMmMd gdlltisa eM ar«W drl an<• OD O -" , _- b *EN18 1 exc••tlMe2-hourop«ellonrycMllmltwrlaneuPR+rokeYdwlaweMtl•avAMhi•inWbd en rwI e e D a•eb coed om ae,naaPad agdx mom". Y ' Hummr/N ArcNgcq CH2M HILL Oro,Gtxvoom oo.: dgrid ladavAreB .em°pbyee lunch entl bnekWioome prlwb dRu� .. BOW,ID. n rpr 30 rR AuWmrtican sanaar poww on p powwr. 1 27d5 Nam Bagu PL 3g2 Eed Fm I StreN roabwm••ntl n« c 0 R xl al rl oc Ml.I.Ang th CONTROL ROOM;, _ i1= '� '1 ' - �/ 1I - S.Ix,m Excepbnlol <sD«a.r I I e. LU 75 01nPoI11LI R II -�y H1241 B 1 ® � e oed Lc ❑ bdMmB ocee m�•doan axlo-de era pslmnee wn«e manual-m opwlbn wvde emenB«me eerery n SL1 I' \ I ' 'l,�-,�,, , Li � aria Nofee man or 10 O 1 L ----`~--•. B ® A.F.E 1`!8---L-- Section 2:Interior Lighting and Power Calculation 1.D•Nlohl mnx h ndamm,wwbwl lid 1�--',--, _ 13 e ❑ Iq nBa"IRd.lndep«bent ham tll.t nldxB.nelalereaRBndnB d,et.n.Rn«m.rwM cr N J - '� 9'-6'AF.F. 1 ' ` ® ', - auWmeucamaoa•mnx<.2snD n2amaulM« LLI 1 ' 1 ed_ ® I T ', �'C d ." ____-1 .-�--(- „1-�.-. <``\ A B C 0 ran daylghl mms agecerd b Wllbal brrodntlon. akylgm.mad brn 15 bat Imm Na pedmal«Here IgMin \ J ,--.-,a ', , i 1 g conwle xwrab / 1, 1 \ 1-- , M•Cmagory Flooran. Aawwd Allard Wa11a ExasplM(a): 1 '' 1 I " ry EN16 Haald•zn ClbldHx Rd,Ur laa lb M lau Wdtr/R2 BRC ❑ Candgupus da bM mm•vp•mlNno mad qen hW agntrtlmr«•aAowwtl to b•cmlmlbd bYe akele aml dYNdrdx. G6 _EN1 -1 Res 17 1 ) ❑ Daylight spaces enchced eR.a WImB height peNRorb and mM•I LL Told avowed wetle• a�7s b/'w dre lwaagw«uBnt mm,ros ere na ngal.d Mnewe L_�+- , e ---- b - gemrel ens Ightlnp, r --t'-• 6UAL PLA ELA I \ a.AlmodaW daylight-awd.•ro cWWl•or r•dad O r _ ` - - 1 '- ' Section 3:Interior Li htin Fixture Schedule ❑ nB pawmdud pmngn mnumau.almmlW wq.q.nd 1 I 1 , _�.. _-L' B g oonmdayria-da controls ORnoi onan.a automatic Mawr..on.udng O.PIn=50-70 Pa.- a owdddrq lrM deYlgm-aanel^B /^, IC i I 1 I _--_-, \ I /I Q' 1 "Mad MW rd an hvo arYrd dwlndv p«mn•«q al Neat am conbd daPbthe 50-70 P•rcant nnB•end anWl«<•35 _ B C a E Darxnt ortl elan pow«. I_-JI- , \ I I9'-6•A..T�i 1 - PIMun ID:Didod"Ml/Lamp)W~P«Lamp I"all.. `a W dof FMgn (CXD) ❑9. Madld trek day dlWby RRIMM dMad W be-M horn mmpllenx hall,canhol devbe Ind St Luke's a .-. �..... \ w ) Finan Flxwn. WB. amhd a d,.r and Bx anp lgMkw. Wam.n JL t r�[�LyJ l of Wa 1 1I - ' 11i.. LH�Edpy L1:LED PanelLad>arlwa•gwnt(1g85 R 1 1B 30 570 ❑1D.SmadM eM d«mdnWetlondl0�xnMlgndrp.nxlghdrq,qek NBMbp.narvlwd 1phlkp.unE«-ehedlpanentlghtlnp -Ir`( Aghdnp I Hnith System _ , 1 �1" �( 11.H Mobl.q•pbpunllrrrdBuaslalgahaveaxlholdmoaulatme«Ny door that conbd all P•mnrbntlundminu Mamodw IIII # 15-310 G6 1 I I/ - 1 /�a.� DAlemP 25W: 1 2 24 dd redrpledx. \`G JlMsa:d _ TotTotalPW Dead Weds 21 ❑12.EAa9m5Weua M,mr fin. . I _ _ --r- I ---' S ❑ Section 1D.r.IM.rI wired awN.mp•na mrea«W b.lwled Wmtrdrx(Na.Irel«I.mp benaw). e on 4:Requiremefds Checklist ExaWRanl•1: PROJECT DATE , EOUIPM T110SET - -d ❑ El-lo hly.R•quercy eelgm. 428042.MV.09 0529.2015 ® 1 _-_ Llehtina Watlaer. ., -,1 1 ' i _ wI ❑ LumbaM ml mxma rwltdl. _ I 20G EN16'1 T`1- H�46� , �1. Taut aapam wem mud be bx Iran or lat.W lad elbwetl wdq. DRAWN CHECKED ..---"- R.gWM Wminelm lO R.apdawma/pment mtcaMnuous.® 1 Nbwrtl WYRapr:3375 ProWaed WMgpe:217e ❑ CLC CJW ' 1 I 1 - 1 J--1•"--1'-.. 'I 9' c vss u m e i- ..y� omPllx� ❑ L mI Ye mem«Bnry chaAq ® - 1 - 1 I G I 1 �.-.-, Mandatory Requlnments: STORAGE G6 ❑Z Dweding umu(axnpbro lndaudoam living tudidx)wdWn aanduroal uAdINr are mt requhad to amNy with lnthat lghdnB REVISED I dMammmb a mle code P-MI that•75 pam«d ofNe Permanently lmall nMune otlel than low Mdgge lghdrp.-only Section 5:Compliance Statement high eRmry lempe - 1 ' 1 ' 3. Menud Conhda Each andoeed 9'-8"AFF. ❑ spec•nx monad IIghIWg mno-ol.RemabN gnl•d mewlconwN aro gMll•d for.raeWxmce CanPy Sggmea:Th•luop- lighting-amalmProled no--hthi doameml fifth, w1NNehoadl,plan., end Inaaeq adan euma �a�yr,(N. epcMmtlom end otller ralaglbn wbmltletl wits lhb parmR eppllo yeti ll hd �J-"" ® , _ ,•.,- B p Dmlra hn bxndaagmdto mxl `-.� MaZ121ECC.Cladd d,r•qulranwlq In COMcheck VaNm 3.g.2 I 1 uMmema In be R Iromente 1 1 ❑ 9auadylamemenry aged Wlh 2d�hour operatlm. Cnaddbl. equ d `':.'..;., ❑ sldm.ydm Ma•Nalero m.«.deD.x. .. .;'..•''I - d. L19M Padua.Corral.:Each, -ralmh bMveam•nud '�. ❑ W 9 anlyd dx dbwef I � aredudWmamnnedsdiglmgbwladbed +I2� .e, ob.io,is ' 1 1 --�- ' -_--'-�"' "'": - '�I'`"' '.�+,"'..�.+';• 1 1, 60 pertem by•Rn«canbdinp ed IumMaksr,tlud awdcning olellemeq rare a lumhmde WemW lumina Nadal- ��� J- 1 __J-,^./",...,:., :.•+�.,�...",':;,\(.['�,',.+'..:...'.- •:�.':.':,',11 - 1 1 9 vwlWNng dw middle mu lumlrnlm lMapentlarltlY oloOwr gmPa,awMcrkp arcnWMndn or such lamp e.aetlemeb bmpe. me Tida e ,((�{_� S e Data M ❑ OnlY one lumindre(bmp<1W IMMam. '1 1 11 11 L 11 1 ' 1 1 - 1 _ 1 _ 1 1 I- It IC . . L LUMINAIRE SCHEDULE 6/1012015 '. : - 1 I 1 `:. ,,,.,.,y.'..:. , , ' '. .. ,:.'.•'<.'.. 7 ,,•:. TypE MANUFACTURER CATALOG NUMBER LAMPS WATTAGE VOLTAGE MOUNTING COMMENTS I 1 - CLi GOTHAM ALEDI8ARWOLTNSD LED 30 120 RECESSED 6'ADILSTABLE DOWN LIGHT;NOTE El LITHION4(ALT.EXIOE HUBB.,SURELn Z) LES w1G 120/277 LAWS INCLUDED EXEMPT 120 SURFACE EXF SIGN SINGLE FACE(GREEN L.EDS) SHEETTITLE R12 LITFION1Vt 2FTTL240L WOLT EZI LP840 NBO LED 40 120 RECESSED VOLUMETRIC LIGHTING 2x2 LED;NOTE7 N SO SKYTRON H24100 HALOGEN 24 120 RECESS® AJUSTABLEOOWNLIGHTW/RB.IDTENOTES LIGHTING LIGHTING PLAN Y3 L MON 4(ALT.ALKCO,CHLORIDE S IBffq LRP 1 RC 120/277 CUSNM LET HINIG LAMPS INCLUDED AED(L EXE P 20 RECESSED N USE,WL,RED LET HS WTR CLEAR BAL1 GRO NIT NOTEB PLAN S SWITCH(LffFIDNW) n-PoIX92P D'WH 120 PUSIel1TTON SWITCH,OWOFF,11PDDWN DMMHR 1/4"=1'-0° S WhilROLBR(LITHIONIA) n-PODGFXWH 120 n-LIGHTTOIDHRAD NOTES: 1.GENERAL NOTE DESIGN IS BASED ON FIRST NAMED MANUFACTURER THEALTBINATE MANUFACTURERS ARE ACCEFrABLE SUBJECTTOCOMFLIANCE WITH THE SPECIFIED REOURSMTNTS,MODEL NLWBETR TY PE ANIDIOR CATALOG NUMBER 2.GENERAL NOTE CONTRACTOR SHALL PROVIDE AND OOORDNATE ALL FIXTURE MOUNTING ACCESSORIES. SHEET 3.NOT USED 4.GENERAL NOTE ALL LAWS ARE TO BE TCLPOOAPLIANr. 5.GENERAL NOTE REFER TO LIGHTING BANS ANDARCHITECTURAL DETAILS.PROVIDE QUANTITY OF FKTURES AND INSTALLATION FEATURES AS REQUIRED.7LRCO OL S4UIFd3MENT5,SESSHEET Q01, .FOR rE V e oS.SEE SKY TRON ARGO II INSTALLATION MANUAL AND NSTRIICTIONS PRIOR TO INSTALLATION COMMUNICATIONS PLAN NOTES: ybo (FOR LEGEND AND GENERAL NOTES,SEE SHEET E1.0) � w M4.io \\ C1. GENERAL NOTE: FOR EQUIPMENT SCHEDULE,SEE SHEET E8.0. C2. GENERAL NOTE: ELECTRICAL DEMOLITION INCLUDES,BUT IS NOT LIMITED TO TELEPHONE,NURSE CALL,AND PAGING SYSTEMS. (FOR REFERENCE ONLY). o I , C3. GENERAL NOTE: UTILIZE THE CURRENT ISSUE OF THE SLRMC INFORMATION TECHNOLOGIES COMMUNICATIONS DEPARTMENT VOICE AND DATA CABLING SPECIFICATIONS FOR APPLICATION TO THIS PROJECT. C4. GENERAL NOTE: EXISTING CATEGORY 6 CABLES REMOVED FROM OUTLETS IN THE DEMOLITIONED WALLS MAY BE REROUTED TO NEW OUTLETS,WHERE APPROPRIATE,AND RE-TESTED FOR SPECIFIED PERFORMANCE. C5. ALL COMMUNICATIONS SYSTEM CABLES FOR OUTLETS SHALL BE ROUTED FROM THE OUTLET TO THE IDF FOR THAT FLOOR,UNLESS OTHERWISE NOTED. PROVIDE CAT.6,NON-PLENUM RATED CABLE;DO NOT ROUTE I THROUGH PLENUM AIR SPACES. 4 C6. GENERAL NOTE:FISH 3/4"FLEXIBLE CONDUIT FOR RUNS IN EXISTING WALL,OR TO NEW OUTLET BOXES MOUNTED IN EXISTING WALL. o I � C7. CONTRACTOR WILL PROVIDE A STUB-UP FOR EPIC RECEPTACLE.STUB-UP SHALL BE A MINIMUM ABOVE Do 00 CD c) I FLOOR FINISH OF 18",AND A LOCATION WITHIN SIX FEET OF EQUIPMENT. COORDINATE WITH EPIC EQUIPMENT ELM INSTALLATION MANAGER AND ST.LUKE'S CONSTRUCTION MANAGER.SEE ARCHITECTURAL ELEVATIONS. ao v� p g _ 1 1 CONTROL ROOM M O-to ' 1 Hi2f2A OTE C8 C8. COORDINATE WITH MECHANICAL CONTRACTOR PRIOR TO INSTALLATION OF HUMIDIFIERS. O IM_M I Q0 T s Q dLnN '{ ANGIOLAS 2 J (n 20F PO BUTTONS t'1 q H1242 — J EED A COVER I � { S2 m LaL • EOUIPMENT_ROOM M 1 I H1241A W Z } NOTE C8 T NOTE C5 i s Q { H % . it I 2 = Lu t._—_— NOTE C7 DUAL PLANE LAB ,I l� 2 �•I it '1 T � & H U 41 � o NOTE C5 Z _3 75 '1 1 CONTROL ROOM O >> J r- N J L� H12418 -- W NOTE C7 2 G 0 2 O vJr�/^� - - II 8 AL St Luke's Health 15S# 310 2 1� i +44"AF PROJECT DATE { EQUIPMENT CICIS i 428042.MV.09 05.292015 1 T H12426 20G 1- I +44",A 1 DRAWN CHECKED Q STORAGE CLC CJW H1241C I ,j REVISED '1 ,{ 1 'I 8A 7A 6A SHEET TIRE " COMM COMMUNICATIONS PLAN PLAN 1/4"=1'-0" SHEET AOD —1 1MCA AI.—A.vo.a__ nnAe,ncun •n nv-.n•u. 0b0 s FFA FIRE ALARM PLAN NOTES: ! u ' (FOR LEGEND AND GENERAL NOTES,SEE SHEET E1.0;FOR LOCATION PLAN,SEE THIS SHEET) FIRE ALARM LEGEND �--- F1. GENERAL NOTE: COORDINATE WITH OWNER TO PROVIDE VOLTAGE DROP CALCULATIONS FOR oS�q NEW OR MODIFIED NOTIFICATION CIRCUITS,CONTROL SCHEMATIC FOR MAGNETIC HELD DOORS, MULTIPLE DEVICES OF SAME TYPE(ON RISER DIAGRAM) c�R AND SMOKE DAMPERS,(DAMPER SHALL RELEASE UPON DETECTION OF SMOKE WITH FAS FIRE ALARM SYSTEM ASSOCIATED DUCT DETECTOR),AND LISTING/INSTALLATION INFORMATION ON ALL FIRE ALARM SYSTEM DEVICES TO CITY OF BOISE FIRE DEPARTMENT INSPECTOR. � FAS MANUAL PULL STATION(+qg AFF TO CENTER) p F2. GENERAL NOTE: INTERCONNECT THE NEW OR RELOCATED,ADDRESSABLE DEVICES INTO THE FIRE SPRINKLER WATER FLOW BELL so W o flu �1 EXISTING FIRE ALARM ADDRESSABLE CABLE SYSTEM. PROVIDE PROGRAMMING CHANGES AND F� {� ' . pp FAS PHOTOELECTRIC SMOKE DETECTOR PD INTEGRATION AS REQUIRED , � � � (R F3. GENERAL NOTE: PROVIDE THE NECESSARY MODIFICATIONS TO THE FIRE ALARM SYSTEM TO ID FAS IONIZATION SMOKE DETECTOR ® ACCOMMODATE THE NEW FIRE ALARM STROBES BEING PD ' STROBE CIRCUITS,NEW CIRCUIT WIRING,SYNCHRONIZED DFDLASH MODULESED;INCLUDE ALL CIRCUITS,i W DULES FOR NEW (R) ' FAS HEAT DETECTOR �W i � AND ALL OTHER NECESSARY COMPONENTS. FAS PHOTOELECTRIC DUCT SMOKE DETECTOR o (R) W 60 m EdSt�st-, F4. GENERAL NOTE: FIRE ALARM DEMOLITION INCLUDES,BUT IS NOT LIMITED TO REMOVAL OF UNUSED y�1 ! _ QED MANUAL STATIONS,DETECTORS,STROBES,AND CONTROL DEVICES. (FOR REFERENCE ONLY). F® FAS FLOW SWITCH (FURNISHED/INSTALLED BY OTHERS) I)D� F5. GENERAL NOTE: PROVIDE ALL FIRE ALARM CONDUCTORS AS REQUIRED BY THE SYSTEM TS ",o- MANUFACTURER IN METAL CONDUIT. SEE SPECIFICATIONS FOR INSTALLATION STANDARD. FAS TAMPER SWITCH (FURNISHED/INSTALLED BY OTHERS) 0 co cc to © a�L'M ` _-- F6. GENERAL NOTE: EXISTING FIRE/SMOKE DAMPERS AND ASSOCIATED SMOKE DETECTORS ARE NOT FAS PRESSURE SWITCH (FURNISHED/INSTALLED BY OTHERS) M Co uM - SHOWN ON THIS PLAN. PIV POST INDICATING VALVE O Q p•oo F7. GENERAL NOTE: PROVIDE TOTAL-COVERAGE SMOKE DETECTION TO CONTROL THE FIRE/SMOKE dmN a DAMPERS OF THE HVAC SYSTEM FOR THE SPACE SERVED,IN ACCORDANCE WITH I.B.C.715.3.2.1, C (X) QUANTITY. ESSABLE CONTROL/RELAY MODULE. (X)INDICATES `•,a�J , ACTUATION METHOD 5. THE NUMBER IN PARENTHESES BY THE DAMPER/ SAND DETECTORS J EP6b INDICATES THE HVAC ZONE SERVING THE SPACE. ANY DETECTOR WITHIN A GIVEN ZONE WILL CAUSE THE DAMPERS OF THAT ZONE TO BE COMMANDED CLOSED,VIA AN ASSOCIATED CONTROL X) FAS ADDRESSABLE INPUT MONITOR MODULE. (X)INDICATES CO < N O(R " D MODULE FOR THE GIVEN FLOOR. SEE ALSO,SHEET M0.3 FOR REFERENCE,HVAC SERVICE AREAS. IM QUANTITY. TYPICAL. Z W F8. PROVIDE COMMAND/MONITOR MODULES IN SAME ROOM AS FIRE ALARM PANEL(S)FOR INTERFACE X a FAS STROBE LIGHT,WALL MOUNT(+80"AFF TO BOT.);(X) m '� 30 WITH DOOR HOLDERS/RELEASES FOR THIS FLOOR TYPICAL W INDICATES CANDELA RATING IF GREATER THAN MINIMUM OF 15, w' Q (R) --""�" . . TYPICAL 0 J F9. PAGING SPEAKERS,AS A SUPPLEMENTARY SYSTEM USED FOR EMERGENCY CHIME AND VOICE FAS STROBE LIGHT CEILING MOUNT BROADCAST OF FIRE ALARM CONDITIONS PER CITY OF BOISE PERMIT NO.FIR99-0596,SHOWN FOR �C , T W REFERENCE ON THIS PLAN. TYPICAL. W H FAS SPEAKER,WALL MOUNT(+80"AFF TO BOT.); ?� �,!•"____ F10. STROBES SHALL HAVE A MINIMUM INTENSITY OF 15 CANDELA,UNLESS OTHERWISE NOTED, 'H'INDICATES HIGH SPL SPEAKER VERSION,TYPICAL (HONEYWELL MODEL NO.SC807 SERIES)AND SHALL MEET ALL REQUIREMENTS OF ANSI 117.1. C� FAS SPEAKER,CEILING MOUNT U Q MOUNT DEVICES SO THAT STROBE IS+80"AFF TO BOTTOM. PROVIDE#12 CONDUCTORS(UNLESS VOLTAGE DROP CALCULATIONS REQUIRE LARGER)FOR STROBES. PROVIDE SYNCHRONIZED �� FAS SPEAKER/STROBE LIGHT COMBO,WALL MOUNT(+80"AFF TO Q O' FLASH MODULE(S)AS REQUIRED FOR ALL STROBES. TYPICAL. LJ� BOT.) F11. W 73 PROVIDE DUCT SMOKE DETECTOR IN SUPPLY AND DISCHARGE DUCTING FROM RTU,IN ACCORDANCE �� Z Z WITH MANUFACTURER'S INSTRUCTIONS. LOCATE REMOTE LED INDICATOR AND TEST STATION IN L� FAS SPEAKER/STROBE LIGHT COMBO,CEILING MOUNT N J CEILING SPACE OF ROOM BELOW DETECTOR. PROVIDE SAMPLING TUBE FULL WIDTH OF DUCT. Wp (SUBSCRIPT)WEATHERPROOF \ W TYPICAL. / J N F12. PROVIDE A COMMAND MODULE TO CONTROL EACH NEW FIRE/SMOKE DAMPER POWER CIRCUIT. AMP FAS AMPLIFIER a FIRE ALARM PLAN COMMAND MODULE(HONEYWELL NO.TC810 OR APPROVED EQUAL). LOCATE MODULES IN SAME CP FAS NOTIFICATION CIRCUIT/AUXILIARY POWER SUPPLY J 1/8"=V-0" ROOM AS FIRE ALARM PANEL(S)(SEE LOCATION PLAN,THIS SHEET). UPON SMOKE DETECTION IN r^ 0 CORRIDOR,PROTECTED SPACES,OR UPON LOSS OF POWER,DAMPERS SHALL OPERATE TO CLOSED ® ELECTROMAGNETIC DOOR HOLDER vJ00 POSITION. '' ® INTERPOSING RELAY/CONTACTOR. COIL VOLTAGE AS REQUIRED. ,AL St L Luke's WIRE CONSTANTLY ENERGIZED OR'FAIL SAFE'. r Health system F13. DESIGNATION OF FIRE ALARM PANEL AND LOOP ASSOCIATION FOR DEVICE;EXAMPLE-'P2/L2' FAC FIRE ALARM CONTROL UNIT # 15-310 INDICATED DEVICE TO BE CONNECTED TO FACP PANEL 2,LOOP 2. INTENTION IS TO PROVIDE LOGICAL ASSIGNMENT OF DEVICES IN RELATION TO THE FIRE SPRINKLER ZONING FOR A GIVEN FAC FIRE ALARM CONTROL PANEL SPACE. TYPICAL. PRaECT DATE NCP NOTIFICATION CONTROL PANEL 428042.W.09 05.29.2015 F14. MOUNT AREA DETECTOR(RATED FOR UP TO 1500 FPM AIR FLOW)AT TOP OF DUCT UPSTREAM OF SMOKE DAMPER FOR SHAFT PENETRATION,IN ACCORDANCE WITH U.B.C.713-10,ACTUATION FAA DRAWN CHECKED METHOD 1. ALSO REFERENCE NFPA 72 HANDBOOK,FIG.A-2-10.5.2(a). COORDINATE WITH MECHANICAL FIRE ALARM ANNUNCIATOR clJc cjw CONTRACTOR AND OWNER FOR ACCESSIBILITY FROM COMMON ACCESS PANEL DOOR WITH SMOKE FISOI FAS SLC ISOLATION MODULE DAMPER. PROVIDE RELAY IN BASE AND REMOTE L.E.D. FIRESTOP PENETRATION OF DUCT. TYPICAL. REVISED OTs FIRE ALARM INDICATING LIGHT(RECESSED IN CEILING) 'TS'INDICATES INTEGRAL TEST/RESET SWITCH 2)E5.0,Fire Alarm ®D FIRE/SMOKE DAMPER CONNECTION POINT a.Reinstall and or relocate as per NFPA 72. jb.H no Fire Alarm plans are required,the sprinkler contractor shall provide a scope of work document indicating what work was done and that the system is back in service.This document shall be submitted to the City Fire Marshal prior to the request for a Final Inspection and or the Certificate of Occupancy. Fire Alarm Plans are required when, a.Replacement of the Fire Alarm control Unit. Provide:battery calculations,verification that sound pressure level measured in dBA are adequate,system components are compatible,and use pertinent sections of the plan review worksheet included in this manual. b.Addition of 11 or more fire alarm initiating devices. Provide:battery calculations,verification that sound pressure level measured in dBA are adequate,system components are compatible,that circuit capacities are not exceeded with new devices,wiring diagram showing the connection between new and existing systems,and use pertinent sections of the plan review worksheet. c.Addition of 3 or more fire alarm indicating devices,including horns and strobes. Provide:battery calculations,verification that sound pressure level measured in dBA are adequate,system components are compatible,line voltage calculations for lines with new devices,wiring diagram showing SHEET TITLE connection between new and existing systems,and use pertinent sections of plan review worksheet d.If a permit is not required,provide a system certification form and a basic as-built plan showing the location of FIRE the new devices and which circuit was augmented. Note:The device addition limitation to a system is cumulative for an annual period.For example,if 3 devices ALARM require a permit and 2 devices are added one month and 2 devices a month later;it does not negate obtaining a PLAN permit.As soon as 3 devices,cumulative,are reached,a permit should be required. SHEET I��V ■ V SECOND FLOOR P Sib/) zw MNr 2[h],2[p] [h],[p] Ins oQr CPI [P] [h] [h] [h] [pl [4]TO 2[h] cN�y1 ELEC H1596 [9]TO IN IN- ELEC H1541 [h] [h] J Z z J J04 J (FUTURE) z z z z z z z z IN o 314"G(4#10, M (1)t10G nt COW'. r 0� F00, IDAHO POWER COMPANY TX-SNLB H1 ^� ~ o a0 m� 0 PRIMARY METER ( ) (IPCO)TRANSFORMER In] -- N N M o'atn BY IDAHO POWER CO. _ _ _ _ g O m aiM 480/277V,3 PH,4 WIRE, 00 SECONDARY,SEE NOTE 4 m = _ -1 J p o0 CO CV PRIMARY CABLE BY (SITE) (SITE) a -J co IDAHO POWER CO. [I] [i] NOTE 7 NOTE ¢ m e [a] NOTE TVSS 10 [P] Z NOTE 7 SERVICE ! [a] SERVICE [b] 3[P] m [9] DISCONNECT K DISCONNECT K [h] 2[Pl Q ~ (H2) H1 _ _ J IDAHO POWER COMPANY — [9] ( ) } n1 I- 480/27 TRANSFORMER N G [9] = N G [9l z z W 480/277V,3 PH,4 WIRE, � �, r SECONDARY,SEE NOTE 4 2[h] Q 0 FIRST FLOOR - V O 0 W TO TRANSFORMER GROUND RING [d] TX-BNLBDP(H1) Z Z (GROUND RING FURNISHED AND M❑ M I i = _ z m N 73 INSTALLED IN SITE PACKAGE). M ( IF71-911 BNLBDP(H1) ci o w [b] [e) ( m m m p z d _ [k] P] TVSS [h] 3 h J a C m [el TX-BNLADP(H1) [h] [ ] �p [n AL St Luke's [h] �r Health SYstem = EM [9] BNLA4TVSS z r # 15-310 [N+l m PROJECT DATE m M [z] _ [Il [k] _ = _ _ = 428042.M O9 os.zs.zots DRAWN CHECKED —� CLC CJW NOTE 7 M m m m 1 m m z m K M REVISED BNHFDP(H1). (FUTURE) [e] tt [c] [I] TV,< m 1 l TX-BNLCDP(H2) [Il M [d] [9] BNLCDP(H2) N [el TVSS J J o M [I] m m [e] TX-BNLDDP(H2) 0] [h] (KITCHEN) (KITCHEN) E m M w z [k] MEDICAL _ I SHEErnTLE Mx AGING BNLDDP(H2) zM [w] = EouIPMENT) m m m NORMAL M [Il TVSS (KITCHEN) (KITCHEN) ONE-LINE M b _ BNHGDP(H2) RISER -TON D ------ DIAGRAM NOTE 6, ATS P. S HE EP604 TVSS TYP O ONTINU ION _ [I] LOWER LEVEL SHEET NORMAL POWER RISER DIAGRAM 'E6-.Q' N TS nonnnl SECOND FLOOR :1[x]TO CATH LAB H1242 syb o �Hb 3 O [h] IPI pi" r S g v v v v v [q] (UPS POWER FOR r r r r r = CENTRAL PLANT) [P] [h] (CATH LAB v v 1.... _— NOTE 11 ) [h]'2[P] 2[h] = = x x J r, 2[P] U U [h] co o0 r _._.. ............._. FIRST FLOOR 0 00 -c? °N [4] — FEEDER FROM BNHASWBD(H1), TYP AT ATS. SEE SHEET EP603 ATS-BLLADP(H1) TX-BLLADP(H1) m FOR CONTINUATION ......... ......... M [d] [k] [nl 3[h] 00 z [d] — _ [h] [h] [h] Q ATS-BCLADP(H1) TX-BCLADP(H1) [I] TVSS m J ~ O e [9] = w lei Ii1 BCLADP(H1) Q T [e] [w] = Inl Q TX-BCHQ(H1) .. -' -' -' -' VATS-BC�Q(H1) I V[kl = (MEDICAL [1 m m m Q B O IMAGING (FUTURE) (KITCHEN) (KITCHEN) z Z m [ 73 w] 400 _ U EQUIPMENT) LLI ¢ - n] w w ATS-BCHC(H1) 00 5[Y] IYl [Yl IYl [Yl IY] BUS WAY BEHBBW(H1) m > J (INSTALLED UNDER NOTE 5 O [z] BCHC(H1) [z) BCHCUPS d SEPARATE PACKAGE) BCHHCUPS f ^ -... -_ NOTE 8 [z] --�--- [ ] NOTE ,NOTE 4—,,, NOTE 4 NOTE 4 NOTE 4 J ------ [m] ATS-BMHADP(H1) z MAINT. ^ ^ ^ TO GENERATOR = _ _ _ _ 00 PARALLELING f— M f- M Ifl D v GEAR 1EHSWGR(Z)AT BMHADP H1 ....._. -_ = BYPASS�H1 o a p p o JL St LUk2'S CENTRAL PLANT PARALLEL [f] "' a w a a d Heallh System K [Yl ca BUHADP(H1) _._.- o w 11 _ , r SWITCH ROOM Z1407. [I] TVSS = _ _ # 15-310 SEE SHEET EP601 FOR m m m m m m [9] CONTINUATION. ATS-BLLBDP(H2) TX-BLLBDP(H2) NOTE 4 - PROJECT DATE NOTE 12 d Ik] (SERVER (SERVER (SERVER (SERVER (SERVER 428042.MV.09 os.zs.zos - MO [ ] [n] ROOM H0449) ROOM H0449) ROOM H0449) ROOM H0449) ROOM H0449) [d - LLBDP(H2 Ciao C CECwC = N 0 ATS-BCLBDP(H2) TX-BCLBDP(H2) = REMEo TVSS °c° s ® [e] 191 01 [I] m —�-- BCLBDP(H2) N cv _ [e] [w] ui BUS WAY BEHCBW(H2) ATS-BCHR(H2) TX-BC _ (MEDICAL U (INSTALLED UNDER NOTE 5 M [k] [n] = IMAGING [I] TVSS m m SEPARATE PACKAGE) O CB m EQUIPMENT) [m] [w] 400A TO GENERATOR ATS-BMHBDP(H2) --- D [c]B 2 TO CATH PARALLELING [c] LA GEAR 1 EHSWGR(Z)AT m [fl BMHBDP(H2) CENTRAL PLANT PARALLEL M SWITCH ROOM Z1407. NOTE 6 [fl BCHD NOTE 10 IYl- [b] [a] SEE SHEET EP601 FOR .-. UPS(H2) CONTINUATION. ATS BCHD(H2)W] Ill TVSS [w] [W] (MOB) [h] M t BCHD(H2) BCHD UPS [w] ----�- TX-BULCDP H2 a f�z [h] SHEET TITLE FEEDER FROM BNHBSWBD(H2), — MAINT. [B�UHBDP(H2) � TYP AT ATS. SEE SHEET EP603 IWl NOTE 9,TYPICAL [w] BYPASS H2 TX-BULA(0) _ EMERGENCY FOR CONTINUATION. °' NOTE 7,TYP OF(10)ATS [h] [h]- [hl BULCDP(H2) _ _ RISEREmJDIAGRAM m m KEY NOTE: 1. EXISTING PANEL WITH NEW N N CV N SHEET 2 CIRCUIT BREAKER.SHOWN Z 2 � � � FOR REFERENCE ONLY J z J J m m m m E6:1 LOWER LEVEL C (FUTURE) EMERGENCY POWER RISER DIAGRAM NTS I 208V I �TO SERVICE GROUND PRIMARY m� 30A,2P MAIN CIRCUIT EXISTING ISOLATION POWER PANEL "bQ; BREAKER _�E_-----� 5kVA TRANSFORMER , ~1 120V SECONDARY 3/4'C-8#14(FROM EACH ISOLATION PANEL) 20A,2P MOLDED CASE I CIRCUIT BREAKERS; ---- LINE ISOLATION i____ __i NUMBER OF POLES AS MONITOR ' SHOWN(TYP FOR ALL i ISOLATION PANELS) I I T �T TO DESIGNATED 3 ISOLATION POWER RECEPTACLE PANEL f=__ m® ©m (TYP) REMOTE LINE ISOLATION UNLESS REQD 7 5a - MASTER MONITORING PANEL FOR BRANCH _ CIRCUITAS _m@) ®m NOTED ON PLAN SPANK© ® SPARE h _ II 00 Do RECEPTACLE ;!o c PANEL,AS PART �® ®� � ODLcq OF ISOLATION GROUND BUSHING(TYPICAL M 0:2 PANEL(QUANTI ! ALL CONDUIT CONNECTIONS) M m 0c) AS NOTED ON ; 00 C5 0 PLANS) daO o RI EMERGENCY— RECEPTACLES --- J_ (QUANTITY AS I '?_---'-- _ J SPECIFIED �-� GROUNDING BUS WITH J O 0 0 I O GROUND JACKS AND LaL I i i ---------------- - ---' i�------�� GROUND TERMINALS m i I " ' - , co_'' " ; OTHER SPECIFIC LOADS /ry��� I I AS INDICATED ON PLAN(TYP) Q � II ___I 3/4"C-2#12,1#10G,(TYP) 2 w 1#10 GROUND WIRE 1 ''�; TO EACH ISOLATION POWER > TO BUSHING(TYP) RECEPTACLE PANEL NOTES2 I ISOLATION POWER Q o RECEPTACLE PANEL U Oa EMERGENCY RECEPTACLES �Z LU (QUANTITY AS SPECIFIED) CN i LL1 GROUND JACKS > J 0- �_/�j HEIGHT AS SHOWN v! 000 ON ARCH.ELEVATION (TYP) JL St Luke's SCHEMATIC NOTESI r #He 15-310 enn Sr4am S1. GENERAL NOTE:ALL GROUNDING CONDUCTORS SHALL HAVE AN INSULATED JACKET. PROJECT DATE S2. PROVIDE 1/2"C-1#10G TO GROUND GAS,SUCTION,WATER,HEATING,AND DRAIN PIPES; 428042.MV.00 15.292015 CONDUIT UNRELATED TO THE ELECTRICAL POWER DISTRIBUTION SYSTEM WITHIN THE ROOM;DUCTS; PORTABLE PARTITIONS,STRUCTURAL METAL DOOR OR WINDOW FRAMES, DRAWN cxEOKED AND ALL OTHER CONDUCTIVE HARDWARE IN ROOM. BOND CONDUIT AT BOTH ENDS. 0Lc Will 0'�I!OLATION POWER SYSTEM WIRING SCHEMATIC "� ° E2.0 SHEET ME ELECTRICAL DETAILS SHEET rETO 428042.MV.02-E7.0 CATH LAB V8i.dgn 2015\05\29 10:46:17 AM EQUIPMENT SCHEDULE O1 PC/MONITOR,WALL MOUNT 78"(UON)(10) 51 CENTRIFUGE LARGE 103 ULTRASONIC CLEANER(208V) 156 INFANT SECURITY O2 DESKTOP FAX/PRINTER/COPIER®LION(10) 52 INCUBATOR,INFANT 104 VENTILATOR 15 UROLOGY SYSTEM OVER-RANGE MICROWAVE(2) O MICROSCOPE 10 ECG WORKSTATION 158 DISINFECTION WORKSTATION n s MOUNT IN KNEE SPACE ® MEDIA/GEL WARMER (480V)106 CART WASHER 159® (GROMMETS BY OTHERS) 0 SURGICAL LIGHT 0 3 55 WARMING CABINET(SM) 10 WATER BATH,LAB 160 z W o/W O5 FLOOR MOUNT PRINTERICOPIER(10) HEMODYNAMIC MONITORING �Qr 56 WARMING CABINET(LG) WHIRLPOOL/WATERBATH AUTOMATIC DOOR o © MULTI-OUTLET ASSEMBLY(1) 108 PATIENT(GFI) 161 INTEGRALDORDISCONNECT) 57 SCALE O7 LAB TABLE RECEPTACLE PEDESTAL, 109 AQUARIUM 16 HEMOSTASIS ANALYZER GFI,2-GANG OR 4-GANG AS REQUIRED(7) 58 PATIENT LIFT MOUNT W'ABOVE 110 ABLATION SYSTEM 163 PLASMA ANALYZER ® ABOVE COUNTERTOP IF SH,OR" INFANT WARMER 111 AUTOTRANSFUSION SYSTEM 164 SURGICAL EQUIPMENT BOOM O9 MONITOR,PACS®,LION 60 CRYOSTAT 61 ULTRASOUND 1 BLOCK CUTTING SYSTEM 165 SURGICAL ROOM STATUS 10 MONITOR,PHYSIOLOGICAL 68"AFF 62 FETAL MONITOR 11 BLOOD IRRADIATOR(208V) 1® WON(FIRE)DOOR 11 MONITOR,SURGICAL g3 RADIOGRAPHIC UNIT(120V) 114 HEARING BOOTH 16 A/V EQUIP 12 MONITOR,WAVEFORM DISPLAY 115 CELL WASHERRAD p O 64 MAMIMO 08\0 OGRAPHIC UNIT, O 168 SURGICAL LIGHT CONTROLLER M 13 MONITOR,+gp"AFF,LION 116 CHAIR,ENTlDENTAL °Dcoo 14 TV,+90"AFF(LION) O RADIOGRAPHIC UNIT, 169 EMS RADIO F-- �za; p x=L? O 65 SYSTEM(480) 11 CHLORIDOMETER M m � VCR OR DVD PLAYER, 170 FAN,90"AFF(LION) Lo 15 +34"AFF(UON) 66 TELEMETRY 118 COMPRESSER THIS IS A STANDARD EQUIPMENT SCHEDULE. (1)=6-FOOT PLUGMOLD,OR OTHER LENGTH AS NOTED. 00 CDC? p C'C? 171 MONITOR MOUNT,CEILING SOME ITEMS MAY APPEAR ON THIS SHEET O d ON 16 COFFEE MAKER 719 DOCKING STATION 8 67 ANESTHESIA MACHINE AND NOT ON THE PLANS. O 17 DRAPERY MOTOR,CONTROLLER (2)=COORDINATE MOUNTING WITH MILLWORK INSTALLATION. _j U) 120 ELECTROSURGICAL UNIT(LASER) _J J 17 MICROWAVE,COUNTER TOP(3)®,LION 68 HEADWALL BOOM (LION)=UNLESS OTHERWISE NOTED. (3)=VERIFY MOUNTING HEIGHT WITH ARCHITECTURAL 121 HOLTER SYSTEM 173 EDGE BANDER ELEVATIONS 18 DISHWASHER ® 69 C-ARM D Q 12 HOT PLATE 174 VACUUM SYSTEM(EDGE BANDER) (4)=MOUNT HORIZONTALLY ORIENTED IMMEDIATELY BELOW m LL 6 19 ICE MAKER O 70 CATH LAB SYSTEM(480V) 175 BORING MACHINE CEILING TILE. m Z TABLE, 123 MICROBIOLOGY TESTING 20 PROCEDURE 71 AUTO TRANSPORT SYSTEM 124 176 PANEL SAW (5)=PROVIDE TAMPERPROOF SCREWS WITH COVERPLATE. Q 72 CART LUMINOMETER (6)=INSTALL ABOVE CEILING TILE J 1- 21 TABLE,EXAM 12 17 WASH DRY 73 MEDICAL GAS ALARM PANEL 0 GAMMA CAMERA(208V) = W 22 BED,MED/SURGICAL 36",LION g 126 178 CASH REGISTER®,LION (7)=HUBBELL SA6686 OR SA6688,OR APPROVED EQUAL O 74 EXHAUST LAMINAR FLOW HOOD O HOT PACK 179 (10)=PROVIDE SURGE SUPPRESSION RECEPTACLE O Q DIAGNOSTIC SET,WALL MNT. 12 UPS SAWDUST COLLECTOR Q 23 +56"AFF 75 PNEUMATIC TUBE STATION 180 AIR COMPRESSOR 128 STRESS TEST SYSTEM Q 0 24 DIAGNOSTIC SET,DESK MNT. ® 76 HYPO/HYPERTHERMIA UNIT 181 OVERHEAD DOOR O LU GLUCOSE MONITOR,+56"AFF (� BRACHYTHERAPY SYSTEM 129 BIOSAFETY CABINET Z Z 18 BMS CONTROL PANEL 78 CHAMBER HYPERBARIC N W 25 (LION) 130 THYROID UPTAKE SYSTEM 78 26 ANALYZER,GLUCOSE 131 VIDEO COLPOSCOPE 183 PNEUMATIC TUBE TRANSFER STATION > J 27 ANALYZER,IMMUNOASSAY 79 CHAMBER ANAEROBIC 13 IMAGER 184 UNDESIGNATED EQUIPMENT 0 80 EKG 185 2S ANALYZER,HEMATOLOGY 133 ANGIOGRAPHIC IMAGER(480V) O PALLET JACK 29 ANALYZER 81 EEG 134 TISSUE EMBBEDED/PROCESS BATH 186 WATER COOLER 82 SINK,SCRUB/AUTOPSY ELECTRICAL TANKLESS WATER JL St Luke's 30 ANALYZER,CHEMISTRY(208V) 135 TREADMILL eeeiths ,,, HEATER(208V) �r rs 83 FILM DIGITIZER 31 ANALYZER,DRUG TEST O CT SCANNER(480V) 136 DOSE CALIBRATOR IRRIGATION CONTROLLER 15-310 ® O 32 REFRIGERATOR 13 VASCULAR LAB PNEUMATIC TUBE SYSTEM CONTROL PROJECT DATE 85 INJECTOR 0 CENTER 4280+2.MV.09 BMWs 33 UNDER COUNTER REFRIGERATOR 138 DRYING OVEN® oRawR CHEfMEO 86 LASER,CO2(120V) O BIDET aC CJW MEDICATION DISPENSER/OMNI CELL 139 AUTOCLAVE MEDICATION DISPENSER/OMNI CELL 87 LASER,SURGICAL(208V) O DISPOSAL 35 DESKTOP 88 LYNX AUTOMATION SYSTEM 140 PAPER SHREDDER O PARALLELING SWITCHGEAR REMOTE PC �� O (208V) 141 MRI(480V) 36 MED.REFRIGERATOR O MOTORIZED SCREEN 89 MAIL MACHINE 14 BANDrFABLE SAW 37 HALF-SIZE MED.REFRIGERATOR O BOVL 90 MICROTOME 143 DRILL PRESS 38 FREEZER O LEEP 91 UNDER COUNTER FREEZER ORDER MANAGEMENT SYSTEM 144 VIDEO NETWORK HUB,5-20R 39 480\ O HISTOS 92 145 ( 0 40 CRASH CART/DEFIBRILLATOR/MONITOR OSMOMETER IMAGING SYSTEM O RANGE HOOD 93 OMNICELL NARCOTIC VAULT PLETHSMOGRAPHY 1 MULTIMEDIA PROJECTOR(4) 41 ® 14 42 TAMPER PROOF RECEPTACLE(;) PULMONARY SYSTEM CLOTHES WASHER 95 ILLUMINATOR PANEL SEALER,PACKAGE 148 CLOTHES DRYER 43 96® SLIDE SYSTEM/STAIN 149 WIRELESS HUB 4 STOVE OVEN(208V) () 97 STERILIZER(120\0 150 DIALYSIS PUMP 36"AFF,GFI 45 RF SYSTEM(480V) SHEET TITLE 98 PUMP AORTIC BALLOON STERILIZER(208\0 15 INTERCOM/CAMERA BASE qg 99 STERILIZER(480V) 15 TIMECLOCK ELECTRICAL q7 SOLVENT RECYCLER 100 WASHER/DISINFECTOR 153 VENDING MACHINE EQUIPMENT qg CRSYSTEMREADER SCHEDULE 101 SCOPE PROCESSOR INCUBATOR,LAB 154 POWER SUPPLY,ACC/IDS(6) 49 10 CENTRIFUGE,SMALL ULTRASONIC CLEANER(120V) 155 WATER FOUNTAIN OR FEATURE SHEET 77 50 =_U■OT PANELBOARD SCHEDULE PANEL: BCHQ(Ht) PROJECT: SLMVRMC SHEET#EP1OOb PANEL: 1CLR Ht PROJECT: SLMVRMC SHEET#EP1O1d VOLTAGE: 48OY/277 PHASE: 3 1 WIRE: 4 AMPERE RATING: 400 SC RATING: 14000 RM.HO427 VOLTAGE: 208Y/12O PHASE: 3 WIRE: 4 AMPERE RATING: 225 SC RATING: 10000 RM.11407 ENTRY: MOUNTING: SURFACE PRIMARYMAIN: 35OAC.B MAX AVAILABLE FAULT CURRENT: 4487 ENTRY: MOUNTING: SURFACE PRIMARYMAIN: 225AML0 MAX AVAILABLE FAULT CURRENT: 4078 LOADS: PHASEA: 43043 LOADTYPES: 1=LIGHTING TOTAL CALCULATED O.C.P.AMPS: 194.1 LOADS: PHASE A: 2160 LOAD TYPES: 1=LIGHTING TOTAL CALCULATED O.C.P.AMPS: 20.0 PHASE B: 43043 2=RECEPTACLE REMARKS: PHASE B: 2340 2=RECEPTACLE REMARKS: SERVED VIA PANELBOARD ICLL(12) PHASEC: 43.3 3=MISC a s PHASE C: 1260 3=MISC TOTAL: 129128 4=MOTOR 0 TOTAL: 5780 4=MOTOR LOAD I LOAD AMPS/ CKT CKT AMPS/ LOAD LOAD -' LOAD LOAD AMPS/I CKT CKT AMPS/LOAD LOAD A LOAD SERVED TYPE POLES NO PHASE NO POLES TYPE LOAD SERVED q "' 0 W A LOAD SERVED TYPE POLES PHASE NO POLES TYPE LOAD SERVED VA 500 UROVIEW SYSTEM H22O6 3 100 3 1 A 2 100 3 3 CHESTX-RAYH1285 3500 s ~104 ISOLATION PANEL ANGIOI LAB H1242 3 30 2 1 1 A 2 20 1 1 LGT: 500 - 3 - - 3 B 4 - - 3 - -3500 3 - - 3 1 B 4 20 1 1 1 LGT: 500 - 3 - - 5 C 6 - 3 3500 SPARE 20 1 5 1 C 6 20 1 1 LGT: 2200 X RAYH123O 3 80 3 7 A 8 100 3 SPARE 900 RCP:ANGIO LAB H1242 CRASH CART H1242B 2 20 1 7 1 A 8 20 1 SPARE 2200 - 3 - 9 B 10 900 RCP:ANGIO LAB H1242OMNICELL 2 20 1 9 B 10 20 1 SPARE 2200 - 3 - 11 C 12 540 RCP:CONTRILO RM H1242A WORKSTATIONS 2 20 1 11 C 12 20 1 SPARE 2200 CATH LAB H1241 3 125 3 13 A 14 100 3 3 CT SCAN H1288 1433 360 RCP:ANGIOLAB H1242 2 20 1 13 A 14 20 1 SPARE 2200 - 3 - - 15 B 18 - 3 1433 720 RCP:CONTROL RM H1241B 2 20 1 15 B 16 20 1 SPARE 2200 - 3 - - 17 C 18 - 1-1 3 1433 540 RCP:CONTROL RM H1241B 2 20 1 17 C 18 20 1 1 ISPARE 2200 PET/CT H162O 3 200 3 19 A 20 100 3 3 X RAYFLUORO H1287 2200 900 RCP:DUAL PLANE LAB H1241 2 20 1 19 A 20 - 1 SPACE 2200 - 3 - - 21 B 22 - 3 2200 n 720 RCP:DUAL PLANE LAB H1241 EPIC OMNICELL 2 20 1 21 B 22 - 1 SPACE 2200 - 3 - - 23 C 24 - - 3 - 2200 cn a0o 180 o RCP:EQUIPMENT RMH1241A 2 20 1 23 C 24 - 1 SPACE �tM SPARE 30 3 25 A 26 30 3 3 X RAYFLUORO H1287 6650 O cow) SPACE - 1 25 A 26 - 1 SPACE - - - 27 B 28 - - 3 - 6650 c) p:26 SPACE - 1 27 B 28 - 1 SPACE - - - 29 C 30 - - 3 - 8850 O W m a-'�t SPACE - 1 29 C 30 - 1 SPACE I p Oo 22160 ANGIO LAB 3 100 3 31 A 32 8011 0 3 SPARE Q — dmN SPACE - 1 31 A 32 - 1 SPACE 22160 - 3 - - 33 B 34 SPACE - 1 33 B 34 - 1 SPACE 22160 - 3 - - 35 C 36 J J SPACE - 1 35 C 38 - 1 SPACE -J SPACE - 1 37 A 38 - 1 SPACE m L¢L • SPACE -- 1 37 A 38 - 1 SPACE SPACE - 1 39 B 40 - 11 1 ISPACE Z SPACE - 1 39 B 40 - 1 1 ISPACE ISPACE 11 1 41 1 C 42 - 11 1 ISPACE m SPACE - 1 41 C 42 - 1 I ISPACE LIGHTING RECPT MISC. MOTOR TOTAL LOAD NOTES LIGHTING RECPT MISC. MOTOR TOTAL LOAD NOTES CONNECTED VA 0 0 129129 0 129129 1.DEMAND FACTOR:1ST 10kVA AT 100%;OVER 10KVA AT50%. J f CONNECTED VA 0 5 730 0 0 5,760 1.DEMAND FACTOR 1ST 10kVA AT 100%;OVER IOKVA AT50%. DEMAND FACTOR 1.00 SEE NOTE 1 1.00 SEE NOTE 2 2.LARGEST MOTOR LOAD AT 125%;ALL OTHERS AT 100%. = W DEMAND FACTOR SEE NOTE 3 SEE NOTE 1 1.00 SEE NOTE 2 2.LARGEST MOTOR LOAD AT 125%;ALL OTHERS AT 100%. DEMAND VA 0 0 129129 0 129129 3.GENERAL NOTE:IRATNG OF SUPPLY CONDUCTORS AND > DEMAND VA 0 5,760 0 0 5,760 3.DEMAND FACTOR IST 50KVA AT40%;OVER 50KVA AT20%. LOADING FOR O.C.P.' 0 0 161411 0 161411 OVERCURRENTPA71NG OONPERNECNDUC. LOADING FOR O.C.P." 0 7,200 0 0 7.200 "EQUALS DEMAND VA AT 125%(FOR MOTOR LOADS,SEE NOTE 2) Q C 'EQUALS DEMAND VA AT 125%(FOR MOTOR LOADS,SEE NOTE 2) U Q 0 0 Of Z z N =, > w J U) .00 ALL St Luke's IT #H15-310 WO,ECT DATE 428042.MV.09 05.29.2015 DRAWN CHECKED CLC CJW REVISED SHEET TIME ELECTRICAL PANEL SCHEDULE s�T E8 �1- 428042.MV.02-E8.1 CATH LAB V81.dgn 2015\05\29 11:22:31 AM O t : > O e---- O rhi W II O I� a t� o � N � a S E J _Z L a _ o O N � N 1. Gl N N lx W o N CIO CNN O o x V w M _ O N I LL Q Q Q N U W W m W 0 � W J Wr .J a. x '' O F. W p 00 �' ®RAW0[r G CONTENTS a l z � o 0 a m z J v Cl COVER SHEET w o g Q GN GENERAL NOTES W W W uw oz SECTION A J g U. uj Al EQUIPMENT LAYOUT N CDlz A2 EQUIPMENT ELEVATIONS < °� C A3 EQUIPMENT ELEVATIONS o a A4 EQUIPMENT SCATTER RADIATION DIAGRAMS THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY SECTION S AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT S1 FLOOR SUPPORT LAYOUT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOM SITE ER. THESE SITE PLANS ARE NOT TO BE USED S2 CEILING SUPPORT LAYOUT FOR CONSTRUCTION PURPOSES. S3 FLOOR STRUCTURAL DETAILS DATE: 05-08-15 S4 CEILING STRUCTURAL DETAILS SCALE: NOT TO SCALE SECTION E PLANNER: M.S. E1 ELECTRICAL LAYOUT E2.1 CEILING ELECTRICAL SCHEMATICS QUOTE: 61188-6 E2.2 FLOOR ELECTRICAL SCHEMATICS PROJECT NO. E3 ELECTRICAL DETAILS / POWER QUALITY REQUIREMENTS 150015248VLF2 E4 CABLE LENGTH DIAGRAM (FOR INTERNAL USE ONLY) -c I MINIMUM SITE REQUIREMENTS CHECKLIST GENERAL NOTES STRUCTURAL NOTES ELECTRICAL REQUIREMENTS PROJECT: SITE INSPECTION DATE: CUSTOMER/CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. CUSTOMER/CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. w� GENERA A. THESE SITE PLANS ARE INTENDED TO DEPICT ONLY A CONCEPT OF THE STRUCTURE FOR INFINIX SYSTEM WITH PCDU-100VL I,\ EQUIPMENT DELIVERY DATE: INSPECTED BY: A. TOSHIBA RESERVES THE RIGHT TO CHANGE THESE DESIGNS AND SPECIFICATIONS REQUIRED FOR THE TOSHIBA EQUIPMENT. THE DESIGN OF ALL STRUCTURAL ELEMENTS A WITHOUT NOTICE. MUST BE SPECIFIED BY A LICENSED STRUCTURAL ENGINEER IN ACCORDANCE WITH IN ORDER TO ENSURE A TIMELY AND SUCCESSFUL INSTALLATION, ITJStNECESSARY TO TOSHIBA SPECIFICATIONS AND ALL APPLICABLE CODES. SUPPLY CONFIGURATION: 3 PHASE DELTA OR WYE COMPLETE THIS FORM PRIOR TO INSTALLATION. PLEASE ASSIST TOSHIBA BY HAVING THE B. THE CUSTOMER/CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ALL APPLICABLE 125 kVA CONTRACTOR OR YOUR REPRESENTATIVE COMPLETE THE FOLLOWING: FEDERAL, STATE, AND LOCAL CODES AND ORDINANCES ARE COMPLIED WITH. B. THE CUSTOM ER/CONTRACTOR SHALL FIELD VERIFY ALL EXISTING AND PROPOSED SUPPLY VOLTAGE: 480V - 100 AMP a 0 ALL WALLS, FLOORS, AND CEILINGS FINISHED. WALLS PAINTED, FLOORS TILED, DIMENSIONS AND SITE CONDITIONS PRIOR TO COMMENCING CONSTRUCTION. 1. AND CEILING GRID WORK AND FIXTURES INSTALLED. C. PRIOR TO EQUIPMENT DELIVERY AND INSTALLATION, THE SITE MUST BE 100% 11-06-14 COMPLETE, CLEAN AND FREE OF DUST. CUSTOMER/CONTRACTOR AND TOSHIBA C. THE TOSHIBA INSTALLATION PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY m 2. MONOLITHIC OR LAY-IN CEILING? PLEASE CIRCLE ONE. - INSTALLATION PROJECT MANAGER MUST COMPLETE A SITE WALK THROUGH 1 WEEK FIELD CONDITIONS ENCOUNTERED THAT ARE CONTRADICTORY TO THOSE SHOWN IN THE m DOORS AND WINDOWS INSTALLED AND LOCKABLE. DOORS PRIOR TO DELIVERY AND DETERMINE ACCEPTABILITY FOR DELIVERY. TOSHIBA SITE PLANS. - ELECTRICAL NOTES 0 3 PRIOR TO DELIVERY BY CUSTOMER OR CONTRACTOR AND REINSTALLED BE REMOVED EINSTALLED AFTER D. ANY CABINETRY THAT MAY BE REQUIRED TO HOUSE VIDEO RECORDERS, MONITORS D. THE DEMOLITION, FABRICATION, AND.ERECTION OF SUPPORT STRUCTURES FOR TOSHIBA CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. EQUIPMENT MOVE-IN. RESERVE SECURE ROOM FOR STORAGE DURING KEYBOARDS, OR OTHER ANCILLARY EQUIPMENT SHALL BE SUPPLIED AND INSTALLED EQUIPMENT SHALL BE PERFORMED BY THE CUSTOMER/CONTRACTOR IN ACCORDANCE A. THESE SITE PLANS ARE INTENDED TO DEPICT ONLY A CONCEPT OF THE ELECTRICAL INSTALLATION. BY CUSTOMER/CONTRACTOR. WITH THE DESIGN AND SPECIFICATIONS SET FORTH BY THE STRUCTURAL ENGINEER OF REQUIREMENTS FOR THE TOSHIBA EQUIPMENT. THE DESIGN OF ALL ELECTRICAL AREA SET ASIDE FOR EQUIPMENT RIGGING AND MOVE-IN. ENVIRONMENTAL RECORD. ELEMENTS MUST BE SPECIFIED BY A LICENSED ELECTRICAL ENGINEER IN ACCORDANCE E. PROVIDE ADEQUATE VENTILATION WITHIN CABINETRY AND INSTALL AXIAL FANS ON THE WITH TOSHIBA SPECIFICATION AND ALL APPLICABLE CODES. 4. ISSUES ADDRESSED AND RESOLVED PRIOR TO EQUIPMENT DELIVERY (I.E. TOP, SIDE, OR BACK OF CABINETS, IF REQUIRED. E. DUE TO THE DYNAMIC NATURE OF THE LOAD, BOTH HORIZONTAL AND VERTICAL SURGICAL SUITE). - ACCELERATION SHOULD BE INCLUDED IN THE DESIGN-CALCULATIONS FOR THE SUPPORT B. IN ACCORDANCE WITH NEC ARTICLE 517-72(B), THE EQUIPMENT CIRCUIT BREAKER(S) 5. EQUIPMENT.(INGRESS) ROUTES ARE CLEAR AND OBSTACLE FREE. F. THESE TOSHIBA SITE PLANS DO NOT:INDICATE EQUIPMENT REQUIREMENTS FOR ITEMS STRUCTURE AS WELL AS ANCHORING AND THRU-BOLTING FOR THE TOSHIBA EQUIPMENT. MUST BE LOCATED SO THAT THEY SHALL BE OPERABLE FROM A LOCATION READILY O NOT SOLD BY TOSHIBA SUCH AS, PHYSIOLOGICAL MONITORS, LASER CAMERAS, ACCESSIBLE FROM THE CONTROL AREA. IF THIS IS IMPOSSIBLE OR IMPRACTICAL, THE INJECTORS, ETC. SPECIFICATIONS FOR THOSE ITEMS MUST BE OBTAINED FROM THE F. IN THE INTEREST OF SAFETY, TOSHIBA RESERVES THE RIGHT TO DELAY INSTALLATION USE OF A SHUNT TRIP TYPE BREAKER WILL BE NECESSARY TO SATISFY THIS 0 ALL CONDUIT, TROUGHING (WITH COVERS), AND BOXES INSTALLED (CLEAN AND VENDOR AND INCLUDED IN THE DESIGN TOTALS. COMMENCEMENT UNTIL STRUCTURAL DESIGN DRAWINGS STAMPED BY THE STRUCTURAL REQUIREMENT. THE EMERGENCY OFF BUTTON FOR THE SHUNT TRIP SHOULD BE 6. DUST FREE). GROMMETED OPENINGS, CHASE NIPPLES, RACEWAY DIVIDERS, ETC. ENGINEER OF RECORD HAVE BEEN PROVIDED. LOCATED IN THE CONTROL AREA. COMPLETE.. G. DESIGN, FABRICATE, AND INSTALL MEDICAL GAS PEDESTAL, IF REQUIRED. CONSULT - WITH TOSHIBA INSTALLATION PROJECT MANAGER FOR SUITABLE LOCATIONS. CEILING STRUCTURAL SYSTEMS C. THE CUSTOMER/CONTRACTOR SHALL SUPPLY AND INSTALL ALL CIRCUIT BREAKERS, CIRCUIT BREAKER INSTALLED AND INCOMING POWER (PER POWERQUALITY G. IN ORDER TO AVOID COLLISION WITH MOVEABLE TOSHIBA CEILING MOUNTED EQUIPMENT, 7' REQUIREMENTS) OPERATIONAL AND CONNECTED TO ROOM BREAKER(S). H. CUSTOMER/CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN OPERATING ALL CEILING FIXTURES SUCH AS LAMPS, SMOKE DETECTORS, SPRINKLERS, ETC. MUST BE CONDUITS, JUNCTION BOXES, DUCTS, ETC. SPECIFIED HEREIN. PHONE IN THE CONTROL ROOM AT THE TIME TOSHIBA EQUIPMENT INSTALLATION FLUSH MOUNTED. D. THE TOSHIBA SITE PLANS DO NOT SPECIFY ELECTRICAL REQUIREMENTS FOR UNISTRUT NOTES z > 8. LOCATION OF ALL ELECTRICAL BREAKERS IN POWER CHAIN NOTED. BEGINS. EQUIPMENT NOT SOLD BY TOSHIBA. THESE REQUIREMENTS MUST BE OBTAINED BY 9' THE VENDOR. y ALL CONTRACTOR-INSTALLED STRUCTURAL SUPPORT DEVICES INSTALLED AND I. CUSTOMER/CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE LIGHTING H. CEILING UNISTRUT SUPPORT STRUCTURES TO BE DESIGNED BY OTHERS BASED ON W LEVELED ACCORDING TO T.A.M.S. SPECIFICATIONS ON SITE PLANS. FOR SERVICING OF EQUIPMENT IN ALL AREAS OF THE INSTALLATION. SPECIFICATIONS SHOWN ON TOSHIBA SITE PLANS (IF APPLICABLE). E. TOSHIBA WILL SUPPLY INTERCONNECTING CABLES FOR THE TOSHIBA EQUIPMENT. 10. ROOM LIGHTING INSTALLED AND OPERATIONAL. J. THE CUSTOMER/CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL COSTS I. UNISTRUT OR EQUIVALENT CHANNEL SUPPORT SYSTEM TO BE SUPPLIED AND INSTALLED TOSHIBA WILL INSTALL IF LOCAL TRADE LABOR PERMITS. 0 0 REQUIRED FOR THE ENGINEERING AND/OR REMOVAL OF ANY HAZARDOUS MATERIALS BY CUSTOMER/CONTRACTOR (IF APPLICABLE). F. EXCEPT FOR THEIR USE IN POWER LINE CONNECTIONS TO EQUIPMENT CABINETS, 0. 11 ENSURE THAT LIGHTING/SPRINKLER HEADS PRESENT NO CONFLICT WITH UNITS SUCH S ASBESTOS. FLEXIBLE CONDUIT SHALL NOT BE USED IN THIS INSTALLATION. ONLY FACTORY MOUNTED TO THE CEILING. J. UNISTRUT ARE TO BE P1001 OR P5001 OR EQUIVALENT, MOUNTED FLUSH WITH CONDUIT ELBOWS SHALL BE USED. ENSURE THAT NON-TOSHIBA SUPPLIED EQUIPMENT PRESENT NO CONFLICT WITH K. CUSTOMER/CONTRACTOR SHALL SUPPLY AND INSTALL MATERIALS AND OTHER FINISHED CEILING. ALL UNISTRUT ARE TO BE MOUNTED PARALLEL AND LEVEL WITH A o 12. UNITS MOUNTED TO THE CEILING. - FEATURES SPECIFIED IN THE TOSHIBA SITE PLANS. CUSTOMER/CONTRACTOR SHALL MAXIMUM DEVIATION OF 1/16". UNISTRUT IS TO BE CAPABLE OF SUPPORTING LOAD G. DUCT WORK SHALL BE PROVIDED WITH SWEEP ELBOWS. w SUPPLY AND INSTALL ALL COUNTERTOPS, SINKS, CASE WORK AND CABINETS REQUIREMENTS OF TOSHIBA EQUIPMENT. UNISTRUT LOAD REQUIREMENTS AND DESIGN ARE z �I 13. 110V ROOM OUTLETS OPERATIONAL. SPECIFIED IN THE TOSHIBA SITE PLANS. THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER OF RECORD. H. ALL JUNCTION BOXES AND DUCTS THAT PENETRATE THE FLOOR SHALL BE p D_ = Z WATERPROOF TYPE AND PROVIDED WITH GASKETED WATERPROOF COVERS. ALL FLOOR a o rn 0 ALL CONTRACTOR-SUPPLIED CABLES PULLED AND TERMINATED, INCLUDING PLUMBING K. CUSTOMER/CONTRACTOR TO SUPPLY AND INSTALL UNISTRUT P2751 TROLLEYS OR JUNCTION BOXES AND DUCT COVERS SHALL BE CAPABLE OF SUPPORTING A 8 o In 14. GROUND WIRE AND GROUND BUS BAR IN TROUGHING S'SPECIFIED IN THE L. PLUMBING IS NOT REQUIRED FOR THIS TOSHIBA EQUIPMENT. EQUIVALENT. CONTACT THE TOSHIBA INSTALLATION PROJECT MANAGER FOR APPLICABILITY CONCENTRATED LOAD OF 200 LBS. 0 z = TOSHIBA SITE PLANS. AND QUANTITY OF TROLLEYS. UNISTRUT TROLLEYS SHOULD HAVE VINYL WHEELS. o z w p V M. IT IS RECOMMENDED THAT A SINK BE PROVIDED FOR USE BY PERSONNEL. I. GROMMETED OPENINGS ARE SHOWN FOR REFERENCE PURPOSES ONLY. VERIFY SIZE 3 INTERFACE FOR DIMMING OF ROOM LIGHTS (IF APPLICABLE), WARNING LIGHTS ACCESS NOTE AND LOCATION WITH TOSHIBA REPRESENTATIVE. ALL GROMMETED OPENINGS SHALL o w 15. AND(RELAYS, ETC.). INSTALLED AND INTERFACE AVAILABLE AND CONNECTED SITE CONDITIONS L. CUSTOMER/CONTRACTOR TO PROVIDE TWO 24" X 24" CEILING ACCESS PANELS FOR HAVE NO SHARP EDGES. m < a/ (RELAYS, ETC.). N. DIMENSIONS TO WALLS AND OR OTHER ROOM FEATURES, EXCEPT FOR NOTED COLUMN SERVICING OF CEILING MOUNTED EQUIPMENT. A MINIMUM CLEARANCE OF 36"ABOVE ¢ o AND BEAM CENTER LINES SHALL BE FROM FINISHED SURFACES. FINISHED CEILING IS REQUIRED IN THE AREA OF THE ACCESS PANELS. J. ALL CHASE & GROMMETED OPENINGS SHALL HAVE PLASTIC/NYLON BUSHINGS, z , w y 16. DUST-FREE ENVIRONMENT IN ALL RELATED ROOMS. i 0 o HEATING AND AIR-CONDITIONING INSTALLED, OPERATIONAL, AND STABILIZED PER 0. IT IS RECOMMENDED THAT CARDIOVASCULAR EQUIPMENT REMAIN OUTSIDE 1 GAUSS 11-06-14 K. ALL WALL DUCT WORK SHALL HAVE A MINIMUM NUMBER OF COMPARTMENTS o = Z 17. TOSHIBA SITE PLANS. FILTERS TO BE CHANGED 24 HOURS BEFORE DELIVERY. FIELD OF MR EQUIPMENT. SPECIFIED IN THE ELECTRICAL DUCT LEGEND (SHEET El). TRANSITIONS SUCH AS z w p 0 SPECIAL NOTES HORIZONTAL TO VERTICAL WALL DUCT OR WALL DUCT TO JUNCTION BOXES MUST BE o o V 18. ALL MILLWORK COMPLETE AND INSTALLED. REVIEWED ON AN INDIVIDUAL BASIS WITH THE INSTALLATION PROJECT MANAGER. LOCAL o a z TRANSPORT REQUIREMENTS SPECIAL SEISMIC CERTIFICATION CODES. MAY REQUIRE THE USE OF CROSS-OVER TUNNELS OR OTHER SUCH DEVICES ,� PLUMBING COMPLETED (INCLUDING GASES, IF APPLICABLE) ACCORDING TO P. EQUIPMENT INGRESS ROUTE MUST BE CHECKED PRIOR TO EQUIPMENT DELIVERY TO TO MAINTAIN CABLE SEPARATION. "2 0 19. ENSURE THE LARGEST AND HEAVIEST.ITEMS OF EQUIPMENT CAN BE ACCOMMODATED, A. THE FALLOWING COMPONENTS HAVE SPECIAL SEISMIC CERTIFICATION: w i I i TOSHIBA SPECIFICATIONS ON SITE PLANS - L. ALL DUCT AND CONDUITS SHALL BE ELECTRICALLY BONDED AS A GROUNDING PATH IN o N 1 o {L DIMENSIONS OF CORRIDORS SHOULD BE NO LESS THAN 5'-11". A.A. OSP-0162-10 ACCORDANCE WITH NEC ARTICLE 517-13(B). o 0 0 20. OPTIONAL COMPUTER FLOORING INSTALLED, IF APPLICABLE. PCDU/VRDU (AS APPLICABLE) Q. RECOMMENDED ENTRANCE TO SCAN ROOM SHOULD BE NO LESS THAN 4'-0"W X A.B. OSP-0013-10 0 21. INJECTORS, GAS THIRD PARTY EN PEDESTALS, PHYSIOLOGICAL MONITORING DED ITEMS SUCH AS PROCESSORS, MEQUIPMENT, ETC., 6'-11"H FOR EQUIPMENT DELIVERY. , (AS APPLICABLE M. CUSTOMER/CONTRACTOR SHALL SUPPLY AND INSTALL GREENLEE NYLON MEASURING ��' a a a W EATON UNINTERRUPTIBLE POWER SUPPLY-9390 ) PULL STRING OR EQUIVALENT IN ALL CONDUITS AND CLOSED DUCT WORK. 0 INSTALLED AND OPERATIONAL. A.C. OSP-0088-10 R. CONTACT THE TOSHIBA INSTALLATION PROJECT MANAGER FOR DETAILS OF THE LARGEST AND HEAVIEST ITEMS OF EQUIPMENT FOR THIS INSTALLATION. C & C POWER INC. BATTERY CABINET-BC55 (AS APPLICABLE) N. CONDUIT.RUNS SHOWN ARE SCHEMATIC ONLY. ALL CONDUIT RUNS MUST TAKE THE i--� TELEPHONE LINES (VOICE AND OPTIONAL MODEM) INSTALLED AND OPERATIONAL.22. SHORTEST MOST DIRECT ROUTE POSSIBLE. F- W I DEDICATED PHONE LINE IS REQUIRED FOR SITES THAT ARE RECEIVING NETWORKING REQUIREMENTSB. WEIGHTS SHOWN ON THE OSP DOCUMENTS ARE GENERALLY A MAXIMUM AND THE NNERVISION. S. NETWORK REQUIREMENTS WILL VARY BY SITE. TOSHIBA REPRESENTATIVE WILL REQUIRE WEIGHTS SHOWN ON THESE SITE PLANS REFLECT THE EQUIPMENT AS ORDERED. 0. CONDUIT,RUNS MAY HAVE A MAXIMUM OF (3) 90' BENDS. Lim 23. ALL UNFINISHED AREAS SEALED OFF TO PREVENT DUST CONTAMINATION. DICOM DEVICE INFORMATION, ADDITIONAL I.P. ADDRESSES, AND I.T. DEPARTMENT J 0 11-06-14 11-06-14 EQUIPMENT FOR USE DURING EQUIPMENT SERVICE. CONTACT INFORMATION PRIOR TO INSTALLATION. P. 110VAC GROUNDED OUTLETS SHALL BE PROVIDED ON WALLS NEAR THE TOSHIBA ` L,LJ r RECEPTACLE FOR TRASH AVAILABLE (LARGE ENOUGH FOR SHIPPING CRATES IF V) Li 24 REQUIRED). Lu HVAC REQUIREMENTS Q. CUSTOMER/CONTRACTOR MUST SUPPLY AND INSTALL ALL INCOMING POWER CABLES J X 3: Q 0 FROM CIRCUIT BREAKER(S) TO TOSHIBA EQUIPMENT POINT. CABLE TYPE 25. SUB BASE PLATE(S) INSTALLED (IF REQUIRED). CUSTOMER TO PROVIDE THE NECESSARY HVAC REQUIREMENTS MUST BE MTW. MULTI-STRAND COPPER - NO ALUMINUM IS PERMITTED. CABLE SIZE Q w z Z 26. "PCDU/VRDU/UPS" INSTALLED AND CONNECTED TO "CB'. FOR THE TOSHIBA EQUIPMENT TO OPERATE PROPERLY. MUST BE IN ACCORDANCE WITH TOSHIBA POWER QUALITY REQUIREMENTS. (SEE SHEET > I- L.L_ Q 00 27 SEISMIC REQUIREMENTS, AND REQUIRED SEISMIC ANCHORING DEVICES INSTALLED SYSTEM OPERATION AMBIENT TEMPERATURE RANGE: 64' - 91' F E3). V Z z 0 J RECOMMENDED TEMPERATURE PER ROOM, ENCLOSE INCOMING POWER CABLES IN FLEXIBLE WATER TIGHT CONDUIT FROM CIRCUIT (IF APPLICABLE). R EXAM ROOM: 64' - 74' F . CUSTOMER/CONTRACTOR IS TO SUPPLY AND INSTALL ALL NECESSARY HARDWARE TO {u E o Z 0 W 0 V 28. NETWORK CONNECTIONS INSTALLED AND OPERATIONAL. CONTROL ROOM: 64' - 74' F BREAKER(S) TO TOSHIBA EQUIPMENT CABINET(S). 4 J Z EQUIPMENT ROOM: 73' - 78' F co 29. ALL APPLICABLE PERMITS OBTAINED. S. ANY CHANGES IN THE LOCATION OR TYPE OF CONDUIT, DUCT WORK, JUNCTION Q m J ui WITH EQUIPMENT HEAT LOADS (SEE,EQUIPMENT LEGEND SHEET Al) - BOXES, ETC. MUST BE SUBMITTED IN WRITING TO THE TOSHIBA INSTALLATION PROJECT Q J -1 V NOTICE: HUMIDITY RANGE OF 35-709" NON-CONDENSING MANAGER FOR APPROVAL. N V J Q Z CUSTOMER MUST COMPLETE ALL ITEMS ON THIS CHECKLIST BEFORE SCHEDULED DELIVERY NOTE: w Q J LL W DATE FOR THE EQUIPMENT.IF CUSTOMER FAILS TO DO SO,DELIVERY MAY BE DELAYED. A. A MINIMUM OF 10 AIR CHANGES PER HOUR IS SUGGESTED, CONSULT LOCAL CODE. T. A SEPARATE CIRCUIT, FED FROM THE FACILITY RADIOLOGY PANEL OR A MAIN SERVICE FURTHERMORE,THE EQUIPMENT WARRANTY MAY BE VOIDED. PANEL IS REQUIRED. USE OF A SUB PANEL WITH LOADS SUCH AS ELEVATORS, HVAC, ' W z 0 Z B. AIR SUPPLY DUCTS SHOULD NOT BE PLACED DIRECTLY OVER EXAMINATION TABLES FOR MOTORS, ETC. IS NOT PERMITTED. W U COMMENTS: PATIENT COMFORT. - J Q U. ALL DUCT WORK MAKING A 90' ANGLE MUST BE CHAMFERED FOR CABLE ACCESS. J W C. EQUIPMENT IN ENCLOSED SPACES SUCH AS EQUIPMENT ROOMS, TRANSFORMER CLOSETS - F AND COMPUTER ROOMS MUST BE PROVIDED WITH ADEQUATE VENTILATION. V. JUNCTION BOX SIZES MAY BE INCREASED AS NEEDED (WITH THE EXCEPTION OF THE to 0 19 00 ix " / / J SIGNED TOSHIBA: - D. THE AIRFLOW THROUGH TOSHIBA EQUIPMENT CABINETS IS FROM BOTTOM TO TOP. WHERE PCDU" "VRDU" OR "PDU" JUNCTION BOX). 01-07-15 � 0 POSSIBLE, AIR CONDITIONING SUPPLY OUTLETS SHOULD BE LOCATED AT FLOOR LEVEL 0 CONTRACTOR: WITH RETURN GRILLES IN THE CEILING. Q �i CUSTOMER: E. A/C SUPPLY OUTLET TO BE PROVIDED BY CUSTOMER AT FLOOR LEVEL AT CONTROL ROOM DESK. THESE TOSHIBA PLANS ARE FOR F. A THERMOSTAT IS REQUIRED IN EACH ROOM THAT CONTAINS TOSHIBA EQUIPMENT. INFORMATIONAL PURPOSES ONLY 11-06-14 AND SHALL NOT BE USED FOR G. THE EQUIPMENT ROOM(S) THERMOSTAT REQUIRES A VISUAL AND AUDIBLE ALARM WHEN ANY AN THAT AGREED PURPOSE OTHER BETWEEN TOSHIBATOSHIBA THE TEMPERATURE REACHES 78' F. AND THE CUSTOMER.THESE SITE NOISE SPECIFICATION 11-06-14 PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. WATER COOLING UNIT FROM FRONT CENTER OF UNIT. VIBRATION SPECIFICATION DATE: 05-08-15 65 dB - 3'-3" C-ARM & TABLE COOLANT CIRCULATO ACCELERATION MUST BE 0.397"/S' (1 CM/S') OR LESS, IF FREQUENCY BAND OF VIBRATION R IS LESS THAN 10 Hz. SCALE: NOT TO SCALE 3'-3" FROM FRONT CENTER OF UNIT. 57 dB (71 dB DURING ALARM BEEPING) ACCELERATION MUST BE 3.9375"/S' (10 CM/S') OR LESS, IF A FREQUENCY BAND OF PLANNER: M.S. 63 dB VIBRATION IS EQUAL TO OR MORE THAN 10 Hz. 00. 11-06-14 63 dB XTP-810OG CABINETS CEILING HEIGHT. QUOTE: 61188-6 SOUND PRESSURE LEVEL, NOT ACOUSTIC POWER LEVEL MEASURED S-3" FROM FRONT CENTER AND 3'-3" FROM FLOOR MAXIMUM CEILING HEIGHT: 9'-10 1/8" PROJECT NO. 50 dB STANDBY RECOMMENDED CEILING HEIGHT: 9'-4° 150015248VLF2 53 dB PULSE FLUORO NOTE• MINIMUM CEILING HEIGHT: 9'-2 1/4" A. ALL CEILING HEIGHTS OVER 9'-6 3/16" WILL REQUIRE THE CUSTOMER PURCHASE OF _ ADDITIONAL SPACER KIT (XGHA-001A). B. IF FLOOR MOUNTED C-ARM IS SURFACE MOUNTED, ADD 1" TO THE MINIMUM COILING HEIGHT. 11-06-14 C. IF TABLE BASE AND/OR C-ARM IS FLUSH IN FLOOR, CONSULT SITE PLANNING. 11-06-14 u� TYIQ auccv tC nAn4F AC A QC-r wr lPhsAun11,110- www■■O-111- ... IN EQUIPMENT LEGEND ITEM ELEC. ITEM DESCRIPTION BTUMR WEIGHT REF. / SYM. SUPPLIED AND INSTALLED BY TOSHIBA �1 C830 CAS-830 CEILING MOUNTED C-ARM AND RAILS 136 2,073 1&3 A2 OC810 CAS-810A FLOOR MOUNTED C-ARM 239 1,985 1Azz O O CAT CAT-880B PATIENT TABLE (CRADLE TILT) 1,843 1,389 e ; A2 OMS 58" MONITOR SUSPENSION & BACKUP MONITOR 1,705 425 e c 9'.-.10 15/16'__... ... ..._.. . .. _22'-5 3/4".. �. ORSL 4M TRACK WITH RADIATION SHIELD WITH LAMP 350 167 e 13'-9" O CABS XTP-810OG CABINET SIDE COVER - 89 1 O _ A3 13 3/4" 7 CAS1 RACK CABINET (CAS-830 C-ARM CONTROL CABINET) 1.536 331 m °D ti RACK CABINET 8 CAS2 � J NOTE 1 (CAS-810 C-ARM CONTROL CABINET) 1,161 331 A3 VERIFY K R CO EQUIPMENT IS m O (GENERATOR POWER CABINET) 9,350 508'. ON DESK OR COUNTER PROVIDED N 9 PC1RACK CABINET Z = rn rn rn BY CUSTOMER/CONTRACTOR. O10 pQ2 RACK CABINET - (GENERATOR POWER CABINET) 5,120 508 A y .............................. '�� RACK CABINET W 1 Al 11 DFP (DFP-8000B SYSTEM CABINET) 5,119 926 qa w y -- -- ------ a i Ll STORAGE rr/'� RAID RAID (BTU/HR INCLUDED WITH DFP) - 67 w / o INV INNERVISION WORKSTATION 5 w (15" MONITOR, KEYBOARD, AND PC) 500 22 A3 �w o z CAS-81OA C-ARM T - - - ---i+--.-..--i ROTATION 14 WCU1 HEX-125 WATER COOLING UNIT (WEIGHT WITHOUT WATER) 4,675 67 63 F � w g Z - 2 ! a 0 o z a V t5 15 WCU2 HEX-125 WATER COOLING UNIT (WEIGHT WITHOUT WATER) 4,675 67 e m N P < . 3 m cYi V CCi FPD COOLANT CIRCULATOR (WEIGHT WITHOUT COOLANT) 3,754 98 m } ■7 f � I w � � J ---U r - a a ` _Z' \ 17 CC2 FPD COOLANT CIRCULATOR (WEIGHT WITHOUT COOLANT) 3,754 98 A3 z a 20 SE rCONS DFP-8000D MAIN CONTROL CONSOLE - wawQ 6 5 I; -y CAT-8806 TABLE C DFP-S000D DIGITAL FLUOROGRAPHY _ y o a ------_ + J ROTATION 19 C B CONSOLE CONTROL ERFACE BOX 45 a ,n o -----�--- INT w i v a I o '-� -- 20 LCD LCD MONITOR WITH STAND - D Q N O 26 A3 M a a n Q 26 25 "I 4 0 0 0 0 _ ANGIO WORKSTATION W 21 AWS (21" MONITOR, MOUSE, KEYBOARD, AND WORSTATION) - 51 A3 a a a a DUAL PLANE Cc m LAB H1241 22 MIC MICROPHONE AMPLIFIER - qg A3 I— W 'CONTROL " ' ""' ' ' "" "" """' LARGE MONITOR MANAGER & VIDEO EQUIPMENT 23 LMM m E7 R00 Q2 (WALL MOUNTED) 1,705 261 A; J H12418 ELEC. OPTIONAL ITEM DESCRIPTION- LLJ (� F R WEIGHT REF ITEM SYM SUPPLIED A INSTALLED BY TOSHIBA BTUM . W cf) wf H 6 24 INJ MEDRAD MARK VII.INJECTOR (TABLE MOUNTED) - 7 e J X Q O aW z o � z 25 INJR MEDRAD MARK VII INJECTOR REMOTE PANEL - 5 > 1■■ LL Q 00 R00 EQUIPMENT z 0 15 O8 ao V T. _ . ylp_� 13 1�A 26 INJC MEDRAD MARK VII INJECTOR ELECTRONICS CONSOLE - 43 e � � 0 Z I W L___ 17 O iN ITEM ELEC. OPTIONAL ITEM DESCRIPTION-SUPPLIED BY TOSHIBA gTUMR WEIGHT REF. G z J O W SYM. &INSTALLED BY CUSTOMER/CONTRACTOR G Q m J 23 Q J 16 11 27 PCDU PCDU-100VL POWER CONDITIONING DISTRIBUTION UNIT 2,421 700 p3 uWu Q J JLLJ Q W 4 L 12 27 O ITEM ELEC. OPTIONAL ITEM DESCRIPTION i W L d c)BTUMR WEIGHT REF. z SYM. SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR W PATIENT 28 PHY PHYSIOLOGICAL EQUIPMENT (RECOMMENDED AREA SHOWN) - - G W NOTE: ENTRY NOTE: e ~ 00 SHELF/COUNTER PROVIDED INNERVISION AND RAID LOCATED ON SHELF. BY CUSTOMER/CONTRACTOR. 11'-9" SHELF, BRACKETS, AND ANCHORING SUPPLIED co J 00 AND INSTALLED BY CUSTOMER/CONTRACTOR. < O NOTE 0 N. MINIMUM CLEARANCE LINE RECOMMENDED BY TOSHIBA. NOTE• THESE TOSHIBA PLANS ARE FOR EQUIPMENT LAYOUT INFORMATIONAL PURPOSES ONLY "MIC"AMP IS TO BE LOCATED ON SHELF AND SHALL NOT BE USED FOR BELOW COUNTER. THE SHELF, BRACKETS, ANY PURPOSE OTHER THAN THATAGREED uPON BETWEEN TOSHIBA AND ANCHORING ARE TO BE SUPPLIED AND AND THE CUSTOMER. THESE SITE PLANS ARE NOT TO BE USED INSTALLED BY CUSTOMER CONTRACTOR. D 1' 2. 4' B, 18' FOR CONSTRUCTION PURPOSES. DATE: 05-08-15 SCALE: 1/4" = 1'-O" SITE PLAN APPROVAL PLANNER: M.S. IN ORDER TO USE THIS SET OF FINAL SITE PLANS, A CUSTOMER SIGNATURE IS REQUIRED BELOW. THE CUSTOMER'S SIGNATURE DEMONSTRATES ACCEPTANCE OF THE LAYOUT SHOWN QUOTE: 61188-6 AND ALL STATED SPECIFICATIONS. CUSTOMER: DATE: PROJECT NO. SALES: DATE: 150015248VLF2 I.P.M.: DATE: T411C C41r_3=T IC DA13T AC A CCT A[• ADAZAILA■i± www■uwru�e. we. ■e.��w w.■ ....��w w� �.w �..�... ..�_ __ _--___--- 20'-0 3/16" olo 5'-0 5/8" 10'-4" Z HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) / 830 a o m o 239 136 �j r M o WEIGHT (I,BS) WEIGHT (LBS) r. o o 1,985 r------------------------------1 2,073 C m CAS CEILING °J r------------------r------i I m MOUNTEDNTED C-ARM < CAS-830 U 5'-4 15/16" i {L O CEILING BOX COVER . . ....... .. ....... ...... .. .. . . .. . . .. .. . .. ..... I i I I I 7 I 1 ------------------------------ MONITOR N I i SUSPENSION PLAN J CAS-810A FLOOR 7� MOUNTED C-ARM ILI :2:' I _ M 3/4" 01 1/8" ------- - ------------ -- --- ----------- i EI ` r--- --- -- y I i PLAN I o CL1 ° • CAS-830 ------- o CAS-810A I ------ ----'-I --- -I 1 I I wl Sri Ci ww I li PL —J —_-- - - ----- - -------I- �` o a w Z & CAT-850B I a o O r N K i CAT-880B 1 PATIENT TABLE i ' o o N j 1 i- - _ ° I Z I __ __-_---- ._ --__-__ Es ._ L�j - ... _.....,. .__.__... __._._ ----------- I 3 ,% L9 Du I Lg SUM 1 _�-- 4v ,�" O W 1 I I^ Iao / V�% \ I\ ,/`�'/ w f./ / �O z O Z -�p //ff i L J i0 I Z p =1 yl - I 1 � ; o i0 `�y„ f i E I I 4 METER TRACK "� o W/RADIATION SHIELD oz4 9/16- O LLall, h CAS-830 ^� 6'-6" o 0 0 MOVEMENT I C W I BIDE SIDE .................................................. \ I LLJ 6'-4 13/16" CAT-E FULL,TABLE ROTATION MINIMUM CLEARZONE O CAS-810A FLOOR MOUNTED C-ARM C3) CAS-830 CEILING MOUNTED C-ARM JWHILE FULLY EXTENDED. RECOMMENDED BY TOSHIBA '. W O SCALE: 1/2" = 1'-0" 11-06-14SCALE: 1/2" = 1'-0" 11-06-14 W J (/j � 23'-11 3/8" X � O O 14'-1 5/16" J a/ 1 PLAN MONITOR SUSPENSION CAT a W 9'-8 1/8" 4'-5 1/8° HEAT OUTPUT (BTU's) � ~ W Q 00 } 1,843 V W z Q A ' 4'-5 1/8" 5'-3" WEIGHT (LBS) 7- CAS-810A FLOOR 1,389 a J z _ MOUNTED C-ARM 13 3/4" y m J J g Q CAS—s3o ------------ W J W W CEILING MOUNTED - - C C-ARM {� W \ m \ - ----`--------- }— --- g a- LU > IL W I00 Q O -- —-—-— PLAN 16 I I \ _ 5'-8 5/16" THESE TOSHIBA PLANS ARE FOR CAT-88-08 `^1"� �- INFORMATIONAL PURPOSES ONLY I PATIENT TABLE ANY SHALL NOT BE USED PURPO OTHER THAN THAT M _______ ______ ti___O ! � AGREED UPON BETWEEN TOSHIBA ' ---"', "' ^'..c'7 `'r✓ AND THE CUSTOMER. THESE SITE PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. +yid='^ —___I -------------J fO \ DATE: 05-08-15 \ �j 5'-4 15/16" `t "` Ld Lo j SCALE: AS NOTED a o z CE, mo z ABLE ROTATION N 11 m< m g --- PLANNER: M.S. f 6'-4 13 16" QUOTE: 61188-6 / o 10,-4,� MINIM M ARAN AT FOOT ND TABLE HEIGHT: 2'-7 1/4" (794mm) �- SIDE TABLE TOP SLIDING: FOOT END MAXIMUM FOOT END PROJECT N0. SIDE LONLATERAL TILLRIGHTEAD OWN P16'6 150015248VLF2 INFINIX SELECT QI CAT-880B PATIENT TABLE (CRADLE TILT) A2SCALE: 1/2" = 1'-0" 11-06-14 SCALE: 1/2" = 1'-0" 11-06-14 TWIG QUIMPT IC DADT AC A CCT AtC nn Aun Ikt/_- Ace 0 ■l^ wu w..�...�. ..� �..� ....�... -.�� 101 CABS CAS1 DFP RAID INV w HEAT OUTPUT (EIS) HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU's) / 17 13/16" - 1,536 _-.__._ .. 5,119 INCLUDED WITH 'DFP" 500 WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LEIS) 89 22 9/16" 331 30 7/16" 926 67 22 Q 0 PLAN 11 13/16" 19 7/8" 19 7 8 �W PLAN HEAT OUTPUT (BTU'S) PLAN 22 1/16" _ 3 3/8 co 1,161 PLAN 0 WEIGHT (LBS) PLAN C . 331 PC7 HEAT OUTPUT (BTU's) n 2'-3 1/4" O .� iG 13 9/16" n n 9,350 n 12 11/16° R WEIGHT (LBS) 0 N i N 508 N PC2 FRONT SIDE n HEAT OUTPUT (BTU's) --' 5,120 = z WEIGHT (LBS) N 508 UrEl FRONT SIDE W SIDE FRONT FRONT SIDE_ FRONT SIDE U) 0 CL DFP-8000B It 1 CABINET SIDE COVER O RACK CABINET O SYSTEM CABINET 4 RAID 5 INNERVISION WORKSTATION o D SCALE: 1/2" = 1'-0" 01-07-15 SCALE: 1/2" = 1'-0" 11-06-14 SCALE: 1/2" = 1'-O" 11-06-14 SCALE: 1/2" = 1'-0" 11-06-14 O SCALE: 1" = 1'-0" 11-06-14 yr� ti IL 0o CL w z o � N o_ wCU'I CC1 CONS n CCB rn Z F LCD w z w HEAT OUTPUT (BTU's) HEAT OUTPUT (BTU's) ® HEAT OUTPUT (BTU's) tO HEAT OUTPUT (BTU's) HEAT OUTPUT (BTU's) ° 3 4,675 3,754 m®0 00000 m w WEIGHT (LBS) WEIGHT (LBS) CDo 00© 00000 WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) a o M 67 (WITHOUT WATER) 98 6 if z rn 1 45 18 11/16° 26 m = a ° z z a 0 17 11/16' WCU2 CC2 I3 1 8"----►� s 13/1s" z HEAT OUTPUT (BTU's) HEAT OUTPUT (BTU'S) PLAN o ¢ z V 4,675 12 3/8" 3,754 PLAN 11 7/8"� z PLAN WEIGHT (LBS) WEIGHT (LBS) w t2 i 0 67 (WITHOUT WATER) gg 12 10 7/8" o N o PLAN PLAN 0 0 0 0 14�.w. 9�16,E 1 s�— 1/8„ _ `O a a a W 6 9/16- ❑C7❑ _ a O W o 0 n m LJ m 47t V) 00 N O .Wa w � H ❑ � � X � � 0 FRONT SIDE / FRONT SIDE Q W Z z FRONT SIDE FRONT SIDE > w Q o FRONT SIDE V z Z O J W � � Z DFP-8000D DFP-8000D CONSOLE a v w 0 W O HEX-125 WATER COOLING UNIT O FPD COOLANT CIRCULATOR $ MAIN CONTROL CONSOLE 9 CONTROL INTERFACE BOX 1 Q LCD MONITOR WITH STAND 2 a m J J SCALE: 1" = 1'-O" 11-06-14 SCALE: 1" = 1'-O" 11-06-14 O SCALE: 1 1/2" = 1'-O" 11-06-14 O SCALE: 1" = 1'-0" „ " 0 11-06-14 O SCALE: 1 = 1-0 11-06-14 � V Wo g oL Lu � W w AwS MIC HEAT OUTPUT BTU's HEAT OUTPUT BTU'S PCDU LMM CC LL ( ) ( ) HEAT OUTPUT (BTU's) ___ HEAT OUTPUT (BTU'S) J G z — W W 2,421 1,705 WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) y 00 1% J 18 3/a" 51 49 21 11/i6" 700 261 < 16 9/16" Q LL. �81/18" PLAN PLAN THESE TOSHIBA PLANS ARE FOR 17 1/2^ INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR / ANY PURPOSE OTHER THAN THAT PLAN 8 3 16" 21 1 AGREED UPON BETWEEN HIBA AND THE CUSTOMER. THESESE SITE SITE 2'-0" PLANS ARE NOT TO BE USED 2'_6" FOR CONSTRUCTION PURPOSES. PLAN 14 7/16 DATE: 05-08-15 " a ® SCALE: AS NOTED � N - N o 00 0 0 0 o O e i+> o PLANNER: M.S. m v � O i N QUOTE: 61188-6 FRONT SIDE FRONT SIDE FRONT SIDE PROJECT NO.150015248VLF2 FRONT SIDE PCDU-100VL LMM Ei GIO WORKSTATION '�2 _MICROPHONE AMPLIFIER 13 POWER CONDITIONER 14 LARGE MONITOR MANAGER c��_ OE: 1" = 1'-0° 11-06-14 SCALE: 1" = 1'-0" 11-06-14 SCALE: 1/2° = 1'-0" 11-06-14 SCALE: 1" = i'-0" 11-06-14 VU14M QU==T IC oAMT Ac A QCT we wMs AuElAVw www�u.�..�w �w •wwww w-. w..ww� --.� �..�... -.�_ __ _______—_ f' C • (A) C-ARM ROTATION ANGLE LAO/RAO/CRA/CAU = 0% 100 cm ABOVE THE FLOOR (B) C-ARM ROTATION ANGLE LAO/RAO/CRA/CAU = 0% 150 cm ABOVE THE FLOOR (A) C-ARM ROTATION ANGLE LAO = 90', CRA/CAU = 0', 100 cm ABOVE THE FLOOR (B) C-ARM ROTATION ANGLE LAO = 90'. CRA/CAU = 0% 150 cm ABOVE THE FLOOR Q •0 _ O i \ i •\ / •\ \ i 0.001 0.002 I l / 0.008 \ \ \ I I /: / 0.004 \ \ \ \ % /' �' :y' \ \ \ / / //0;00 j' \ \ 1 1 1 I 1 I / 1 1 I 1 02\0.002 0.004 \ \� % o.0oz 0.00.00 \ \ \ J 1 I I I I I I I I 0.016 I I I I I I I I I I I I I I Z > 1 \ 0.008 - \ / 60, \ / % / \ \ 0.01s / / \ \ \ o.o1s / / H 0.002 /j, i \ \ \ /; i' i \ \ •\ o.00s---'D.00B i i �' \ \ O.00s'--0.008 / O 0.004''--- 0.004 / \ \ 0.004----- 0.004 % i' \ i / 0.002 '•�, i i0:002 � 0.002\ i"0.002• �. cs o a a o O O O 0 50 cm 50 50 cm 50 cm o Z W O 3 � � MICROGRAY PER MICROGRAY SQUARE METER MICROGRAY PER MICROGRAY SQUARE METER MICROGRAY PER MICROGRAY SQUARE METER 0 m ,uGY / (yGY • m') MICROGRAY PER MICROGRAY SQUARE METER NGY / (NGY ' m') NGY / (NGY ' m') 41 N i 0 J O Z Z FRONTAL - 100 cm ABOVE FLOOR FRONTAL - 150 cm ABOVE FLOOR LATERAL - 100 cm ABOVE FLOOR _ LATERAL - 150 cm ABOVE FLOOR a w 0 C 0 o 0¢ z t2 t2 C-ARM CONFIGURATION U 7 C-ARM CONFIGURATION o " a a (FRONTAL POSITION) Z (LATERAL POSITION) p SCALE: 1/4" = V-O" 11-06-14 O SCALE: 1/4" - 1,_O" � o � a 11-06-14 a a a y U W w m J O w (n cn 1- (A) C-ARM ROTATION ANGLE LAO/RAO/CRA/CAU = 0, 100 cm ABOVE THE FLOOR (B) C-ARM ROTATION ANGLE LAO/RAO/CRA/CAU = 0-, 150 cm ABOVE THE FLOOR (A) C-ARM ROTATION ANGLE LAO 90', CRA/CAU = 0% 100 cm ABOVE THE FLOOR (B) C-ARM ROTATION ANGLE LAO = 90', CRA/CAU = 0% 150 cm ABOVE THE FLOOR J X � Q O a W Z p rr) Z > I- Q0 Ci W z � o J w Ooo1 0.001 Az J W o.00z \ \ \ / i o.002 �''\ �.\ `\ �. �._\ \ J Q Z i i- \ \ \ % i i /" i Wp LLJ Ld ALL W o.00ao.00a \ / \ \ Z Z 0.008 \ �,; \;1 \ \ \ \ / % o.00z`\ .00 o.00z`\ \ \ \ --� Q YW. 0.004 \ 1 I 1 / \ 1 I L. ~ W I I I I I I I I I I I oo I N O OL 0.01 s 1 \ \ 0.008 i / l I I \ \ 0.004 / I I ;\ ;\ \ I I ;\ ;\ / LL \ / \ % \ - /` / 0.001 THESE TOSHIBA PLANS ARE FOR ``\ \ \, 0.002 / % `\ / % 0.008 0.008-__-' . `\ '`\ 0.008 /% i INFORMATIONAL PURPOSES ONLY /' \ `\ / /, `\ \` ,\� / /, ,`\ / AND SHALL NOT BE USED FOR , �_____ -i % ANY PURPOSE OTHER THAN THAT 0.00a/0:002 ;/ \ �\0.004 0.004 i' / AGREED UPON BETWEEN.TOSHIBA �•\ _ 0.001 / i, \ '�• 0.001 i' % \ ��\ i 0.002 ` ,i' O.00Z AND THE CUSTOMER.THESE SITE PLANS ARE NOT TO BE USED '\ /" '`\ i' ,\•.\ /i, \.,\ -- i i FOR CONSTRUCTION PURPOSES. -- _ - DATE: 05-08-15 c SCALE: AS NOTED 500 cm 50 cm 50 Cm ~� 50 cm MICROGRAY PER MICROGRAY SQUARE METER MICROGRAY PER MICROGRAY SQUARE METER MICROGRAY PER MICROGRAY SQUARE METER MICROGRAY PER MICROGRAY SQUARE METER PLANNER: M.S. NGY/ (NGY ' m') AGY / (VGY ' m') NGY / (YGY ' m') lsGY / (NGY ' m') QUOTE: 61188-6 FRONTAL - 100 cm ABOVE FLOOR FRONTAL - 150 cm ABOVE FLOOR LATERAL - 100 cm ABOVE FLOOR LATERAL - 150 cm ABOVE FLOOR PROJECT NO. 150015248VLF2 OC-ARM CONFIGURATION C-ARM CONFIGURATION (FRONTAL POSITION) 3 (LATERAL POSITION) SCALE: 1/4" 1'-0" 11-06-14 SCALE: 1/4" = 1'-O" 11-06-14 TY1412 CYCG"T lQ nAM7- /1c A ACT wr wwAu.•uw www.•..�uww Aw .ww..w w-. w..w�� --.� �..�... -.�� �_ ____-_--- FLOOR STRUCTURAL LEGEND ITEM ITEM DESCRIPTION REF. 6 SUPPLIED AND INSTALLED BY TOSHIBA �A CAS-810A BASE S3 ❑B CAT-880B TABLE BASE 1ss .O d•� ITEM ITEM DESCRIPTION m SUPPLIED BY TOSHIBA AND INSTALLED BY CUSTOMER/CONTRACTOR REF. > 0 ANCHOR BRACKET FOR RACK CABINET, VERIFY LOCATION W/TOSHIBA REP. m ❑b ANCHOR BRACKET FOR DFP SYSTEM CABINET, VERIFY LOCATIONW/TOSHIBA REP. 53 0 m cO 12'-10 3/16" ITEM DESCRIPTION ITEM ~ REF. SUPPLIED AND INSTALLED BY CUSTOMER/CONTRACTOR 1 BACKING PLATE FOR RACK CABINETS, VERIFY LOCATION W/TOSHIBA REP. OTE: 53 0 fQ Q LL0 ' o 6' DIAMETER CORE w J rn o 36"W X 36"H, BACKING PLATE FOR "LMM". HEIGHT TO BE DETERMINED AT TIME OF DRILL THRU FLOOR. INSTALLATION. 1 w si Z 2 V N n r� Y/ STORAGE F gj H 1241 C co z N Q 11 3/8" 16" a 0 5 3/8" w a CAS-810ROTATION 0 ro 36" W X 36" H o > o .7 BACKING PLATE C z a I r Z J Z o a A c o d a O U O Z r___ _____________ _- U Z =) �L 0 F CONTROL I DUAL PLANE o i i ¢ D' cYi ROOM LAB H1241 io I i o m m H1241B ��/� s Q li �YJ/ Q O w Z ® CAT-880B TABLE I I z p H o w O ROTATION I }----- o EDGE OF BASE ------------------- -' o a NOTE: o ti A, a < ro C 7" DIAMETER CORE 77 {L DRILL THRU FLOOR. OUTLINE OF WALL (4) 0.406" DIA HOLE o 0 0 0 MOUNTED CABINET Q Q Q Q W ZIOTE: (� 6" DIAMETER CORE i--� MDRILL THRU FLOOR. W w m J CORE DRILL q '. w ca (% F C EDGE OF CABINET W w � EQUIPMENT LARGE MONITOR MANAGER a. x O ,H 241A G O BACKING PLATE 4 luj z_ o r� Z C �O SCALE: 1" 1'-O" 11-06-14 > •"' Q o n Z z ER C) J BACKING PLATE �n 'oI I Z p Q wcn p F C rEDIE —1 WD OF CABINET Q W Q J W W Y w Oz 19 J Q L J w W z � O co U O 9 11/16" 7) C O Q LL w 21 5/8" THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA FLOOR SUPPORT LAYOUT AND THE CUSTOMER.THESE SITE PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. o r 2• a' e1 16' DATE: 05-08-15 SCALE: 1/4" = 1'-O" PLANNER: M.S. QUOTE: 61188-6 PROJECT NO. 150015248VLF2 TLIIC CLICCT IC nAnr AC A CCT f1L e%sAunuw •1A�►••uru�e� tee. •e�.��.. w.. ....��� �..� �..�... ..�� -- ---_—_--- �+ CEILING STRUCTURAL LEGEND ITEM ITEM DESCRIPTION REF. SUPPLIED AND INSTALLED BY TOSHIBA �G CAS-830 CEILING RAILS sa � ElCAS-830 CEILING BOX COVER sa Q CEILING RAILS FOR.RADIATION SHIELD 3 > sa ITEM ITEM DESCRIPTION O REF. rw SUPPLIED AND INSTALLED BY CUSTOMER/CONTRACTOR 13'-9" �J P1001 UNISTRUT OR EQUIVALENT 1 � sa ,Js om (2) 24 X 24"ACCESS PANEL FOR CAS-830, VERIFY LOCATION WITH TOSHIBA REP. O 5'-7" IU Na O OA 0 w _ W Z > n O �•/ N � W W N a G __ UNISTRUT w STORAGE (REFERENCE POINT) H1241C w o d z Z -- —�-- -- o 0 W g O a 0 - z a _ _— CAS-810A C-ARM cm.> N z o N F —� K ROTATION w z w w m 3 a Y U J W 2 z - Z !_ � a CONTROL _Y z o 0 0 ROOM I o o > H1241B o a s DUAL PLANE O LAB H1241 in ^ a ro ® I_ CAT-880B TABLE LL ROTATION 0 0 0 0 0 Lu - — - U W w m I G J w � O J� W w �. x O Q W Z p r-) Z > H L Q 0 V W z � o j O - Z EQUIPMENT Q 0 1 w Q ROOM J Z H1241A a m W U) v J J W w Q U C w J W W Lu y m o I 00 o o L6 CEILING SUPPORT LAYOUT -i— THESE TO PLANS ARE FOR INFORMATIONALONAL PURPOSES ONLY o � 2 a 8 is AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER.THESE SITE PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. DATE: 05-08-15 SCALE: 1/4" = 1'-0" PLANNER: M.S. QUOTE: 61188-6 PROJECT NO. 150015248VLF 'rYI@ CYCCT IC OAnr AC A CLT /1112- ■1lMASw/nu/+ 110%AftIll �c� �e� • •e.��w w.. .�..��� �..� ....�... ..�� 2'-4 3/4" (BASE) CUSTOMER'S CONTRACTOR IS RESPONSIBLE FOR FLOOR AREA AROUND I BASE PLATE TO BE LEVEL WITHIN 1/16" RISE OVER 3'-4" RUN. MAXIMUM TOTAL DEVIATION IN LEVEL AT BASE AREA IS 1/16". -------------------—______z____ 06" HOLE THRU PLATEAT L-------------, / CENTER OF CAS-810A ;1 ROTATION (CABLE ENTRANCE). :2z Q 6" CORE DRILL THRU FLOOR IF APPLICABLE. ¢F I MAXIMUM LEVELNESS MAXIMUM TOTAL ->• o - - -�* \ DEVIATION OVER BASE AREA (N.T.S.) LEVEL DEVIATION (N.T.S.) CAS-810A C-ARM BASE SURFACE MOUNTED ON FLOOR. CAT-880B TABLE BASE SURFACE MOUNTED ON FLOOR. USE SIX 18mm BOLTS THRU FLOOR BASE COVER (PER ENGINEER OF RECORD) 9 13/16 k TABLE BASE SUPPORTING MEMBERS 19 11/16" ° :'':' •: - (DESIGNED BY ENGINEER OF RECORD) CONCRETE z_ m m NOTES: USE SIX 18mm BOLTS THRU FLOOR 12 13/16" A. ALL MOUNTING HARDWARE IS TO BE (PER ENGINEER OF RECORD) 7" CORE DRILL y SUPPLIED BY CUSTOMER/CONTRACTOR. (6) 013/16" HOLES FOR MOUNTING CAS-810A 2'-1 9/16" J-BOX W B. CONSULT INSTALLATION PROJECT ELEVATED FLOOR BASE TO FLOOR. 0 MANAGER IF INSTALLING SYSTEM IN A cc SEISMIC ZONE. C. THE FLOOR MUST USE CONCRETE I - _ CAT-880B TABLE INSTALLATION WITH A LOAD STRENGTH OF AT LEAST NN0 PORTION OF THE ANCHOR 1 9/16" E E O (SURFACE MOUNTED ON FLOOR W/CORE DRILL) 2,560 PSI OVER THE ENTIRE FLOOR BOLT OR THRU BOLT MAY (40mm) „��o I a w SURFACE. THE DEPTH MUST BE MORE PROTRUDE MORE THAN THE N SCALE: 1/2" = 1'-O" 11-06-14 to Ci THAN THE LENGTH OF THE ANCHOR I z w TOP OF THE BASE PLATE o BOLTS. o-N (7/8" FROM FINISHED FLOOR). ro a F N Z o O n O ICAT-880B ANCHOR BOLT -I- w to z 1 --ti-------- r SECTION OF BASE.PLATE p z w p"6 SCALEV : = 1'-O' 3 r30 7/16" 22 9/16" z I- f I I FACE—OF WALL FACE OF WALL x o w 7" CORE DRILL THRU I mw I% I --- ------------�------- --------� FLOOR IF APPLICABLE. z w F ------------- i .'L------------- o -------------------- --------------, N t ^-Ji-u+ 18 1/2" I I I Tj J io I I m I I ro ¢ a J � % ---i \ 9 1/4" \ i °� 11 In \ i i °' u\i c9 o O G I \ I N I I m o O ON Ir Q Z C '� .'� '��.`• w (2) 013/16"THRU (2) 013/16"THRU V- •CAS-B10A C-ARM BASE 6 TABLE _ _ m SURFACE MOUNTED ON FLOOR. \ ROTATION T a a a N W � N 5 3/8" 19 11/i6" 5 3/8" 11 13/16" � y CAT-880B TABLE.BASE SURFACE MOUNTED ON FLOOR. 'c`I n USE SIX M12 ANCHOR BOLTS i� ~ W (DOUBLE CONE TYPE) —I Ld U m 11/16" (18mm) DIA. HOLE MINIMUM EMBEDMENT = 5 1/2" (140mm) zo ��DFP" CABINET SINGLE CABINET W C USE SIX M12 ANCHOR BOLTS (6) 01 N 1 CAT 8LES FOR <o FLOOR BRACKET FLOOR BRACKET W (n LLJ �- J � - � ) (DOUBLE CONE TYPE) BASE TO FLOOR. ~ 10 13/16" ?j 11/16" (18mm) DIA. HOLE � COTE: � Z zMINIMUM EMBEDMENT = 4 1/8" (105 mm) 1. FLOOR AREA AROUND BASE PLATES TO BE LEVEL WITHIN A 1/16" RISE OVER 3'-4" RUN. 21 5/8" (BASE) 2. CONTACT YOUR TOSHIBA INSTALLATION PROJECT MANAGER FOR STRUCTURAL CALCULATIONS > I.. Li Q 0 SLAB ON GRADE WHEN INSTALLING IN SEISMIC AREAS. O Z Z 0 Q j Ov — Z I w _ p 7 TYPICAL FLOOR MOUNTING FOR CAS-810A & CAT-880B V-0" 06-16-14 SCALE: 3/4" = V-0" 06-16-14 O TYPICAL FLOOR MOUNTING FOR CAS-810A & CAT-880B O CABINET FLOOR BRACKETS a m z W SCALE: 1/2" = SCALE: 3/4" = V-0" 11-06-14 to V Q Q V COOLING UNIT NOTES C w - W CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. J G Q 0 z W A. THE WATER COOLING UNIT(S) AND COOLANT CIRCULATORS) ARE SELF CONTAINED UNITS J �j {L TO BE FILLED AND MAINTAINED BY TOSHIBA. PLUMBING IS NOT REQUIRED. F W LENGTH VARIES BY SYSTEM O L. SEE SHEET "S1" B. VENTILATION CLEARANCES AROUND WATER COOLING UNIT(S) AND COOLANT CIRCULATOR(S) MUST BE MAINTAINED. J 0 C. COOLANT CIRCULATOR(S) MUST NOT BE STACKED. 0 STEEL PLATE(PER STRUCTURAL D. HOSES TO THE WATER COOLING UNIT(S) AND COOLANT CIRCULATORS) CANNOT BE RUN IN ENGINEER OF RECORD) _ _ _ ___ _ BACKING AREAS WHERE THE TEMPERATURES DROPS BELOW 407. IF CONDUITS ARE RUN BENEATH PLATE SLAB OR EARTH, ENSURE GROUND TEMPERATURE DOES NOT DROP BELOW 40'F. THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY I I I E. DUE TO HEAT GENERATED BY THE WATER COOLING UNITS) AND COOLING CIRCULATOR(S) AND SHALL NOT BE USED FOR ADDITIONAL VENTILATION RETURN/FAN(S) SHOULD BE LOCATED IN THE VICINITY. ANY PURPOSE OTHER THAN THAT ANDAGRETHEED UGUUNpo BE RE THESE SITE EN TOSHIBA I i PLANS ARE NOT TO BE USED AIR FLOW AIR FLOW FOR CONSTRUCTION PURPOSES. ,n` ^ DATE: 05-08-15 of V ryr N I I I I LI SCALE: AS NOTED AIR FLOWa FAIR FLOW AIR FLOWa ZAIR FLOW PLANNER: M.S. FINISHED FLOOR AIR QUOTE: 61188-6 L FLOW PROJECT N0. "WCU"PLAN VIEW "CC"PLAN VIEW 150015248VLF2 WATER COOLING UNIT AND rj CABINET BACKING PLATE O COOLANT CIRCULATOR CLEARANCE �'� .3_ _ SCALE: 1/2" = 1'-0" 11-06-14 SCALE: 1/2" - 1'-0" 11-06-14 TYIC OLJCCT lC oA eT /1c A I&CT wr ww Au..uw 2'-8 3/8" 5'-11 13/16" 21 11/16" 7'-4 9/16" 9-8 1/8" l` 13 13/16" ¢ 5'-8 1/2" 8'-0 1/16" I� �O 4'-2 13/16" 6'-6 3/8" ' m 13 3/4" O �FINISHED CEILING TO BE 7 1/8" ABOVE BOTTOM EDGE ,c a OF UNISTRUT CHANNEL. 4 5/16" DESIGNED, SUPPLIED, &INSTALLED - CAS-810A BY CUSTOMER / CONTRACTOR ROTATION o rcn rojI O ---- ---- ------ --------- n U I -1 1 -Z�l I UNISTRUT CHANNEL is m °i ----_-. MOUNTING BLOCK \ I J ao -_--- LONGITUDINAL RAIL N L______-_ __ _- N N Lo I MONITOR SUSPENSION BRIDGE OMEGA-ARM GANTRY i0 m ~z j g ----- +---___ _ CAS-B10A C-ARM I I y I I N O CL SECTION A-A SCALE: 2" = 1'-0" \ `a 13 I I o a = Z a o rn cr O n O U 14 9/16" 4'-5 9/16" 14 9/16" N cp N z r CONSULT INSTALLATION PROJECT MANAGER 0 3 (� IF INSTALLING SYSTEM IN A SEISMIC ZONE. o m L J W 14,-01. z n w 5'-10" 13.3/4" NO CEILING FIXTURE OR LIGHTING p a O x Z ALLOWED IN AREA DESIGNATED ABOVE. w p m m ONLY FLUSH MOUNTED CEILING FIXTURES OR p 0 < < 36" LIGHTING WITHIN AREA DESIGNATED ABOVE o z p p (1) ADDITIONAL t2 2 o o UNISTRUT REQ'D CAS-830 ~ n 4 O co FOR MOUNTING CEILING BOX 2 CEILING CLEARZONE Q p COVER. 2'-3 9/16" 4'-7 SCALE: 1/4" = 1'-0" I- J 11-06-14 a a a W y --—- --I--�—- —-- 3'-5 5 15 1 3'-5 5/161. (2) 2a" X 24" o W CEILING ACCESS I— \ (� m PANELS --—- - + —-- 1O 13'-1 1/2" 7 LLI (RECOMMENDED Oj J O c`s LOCATION SHOWN) " " > W n V) F CAS-810A 26 O.C. TYP. 13 3/4 " � C-ARM A 9�i I I � aW z o � Z - - - i-- _ N > Q Do Z z J 4 M TRACK Ov oNI i0 in0 r1`r -1 r, a WJ W Uj O z CEILING BOX COVER Z W n a m 5'-4 9/16" 5'-4 9/16" Q J Q (� A A _ W G.. --- - Y J II J W w W @ z 6'-10 5/16" 6'-10 5/16" J G J LL _ J W B'-6 3/8" 8'-6 3/8" I.: Q 19 J/ J----- �� 00 19 USE (40) 1/2" DIA. X 1 1/2" / �`\ \ O 'a LONG BOLTS, 1/2" LOCK WASHERS, { �`. LL. \ 7 1/16" 4'-1 3/4" 34 5/i6" AND 1/2" UNISTRUT NUTS (ALL TO N BE SUPPLIED BY CONTRACTOR) THESE TOSHIBA PLANS ARE FOR 5'-8 11/16" ' / , 1 R/30" \ R 67" INFORMATIONAL PURPOSES ONLY T11 .ANY FIXED (UNMOVABLE) 3RD PARTY EQUIPMENT MAY BE LOCATED WITHIN AND SHALL NOT LA USED FOR r r THIS ZONE AS LONG AS LOCAL SERVICE HAS REVIEWED EQUIPMENT. IF ANY PURPOSE OTHER THAN THAT i >3RD PARTY EQUIPMENT IS LOCATED WITHIN THIS AREA, CUSTOMER MUST AGREED UPON BETWEEN TOSHIBA r i r AND THE CUSTOMER.THESE SITE r . ...:'.ENSURE THAT THE MOVEMENT OF THE EQUIPMENT DOES NOT INTERFERE PLANS ARE NOT TO BE USED ! ,\ { WITH THE TOSHIBA EQUIPMENT MOVEMENT OR FUNCTIONALITY. CUSTOMER FOR CONSTRUCTION PURPOSES. R 37" f ASSUMES ALL RESPONSIBILITY FOR EQUIPMENT PLACED IN THIS AREA. ----- { DATE: 05-08-15 OFF LIMITS TO 3RD PARTY CEILING MOUNTED EQUIPMENT DUE TO SYSTEM MOVEMELOCATEDNT.WI HrIN THIS ZY FIXED ONE. IFABLE) 3RD PARTY 3RD PARTY EQUIPMENIT^ISNLOCAT DOT BE WITHIN SCALE: 1/4" = i'-0" THIS AREA, POSSIBLE COLLISION BETWEEN THE TOSHIBA EQUIPMENT AND THE 3RD PARTY EQUIPMENT MAY OCCUR. CUSTOMER ASSUMES ALL PLANNER: M.S. NOTE: RESPONSIBILITY FOR EQUIPMENT PLACED IN THESE AREAS. - MAXIMUM EXTENT OF SUPPORT ARM MOVEMENT LATERAL MOVEMENT OF SYSTEM WILL TAKE PLACE WITHIN THIS AREA. ANY QUOTE: 61188-6 " '`-- -------------- ~� FIXED (UNMOVABLE) 3RD PARTY EQUIPMENT CANNOT BE LOCATED WITHIN . THIS ZONE. IF 3RD PARTY EQUIPMENT IS LOCATED WITHIN THIS AREA, LAMP AND SHIELD SHOWN FOR POSSIBLE COLLISION BETWEEN THE TOSHIBA EQUIPMENT AND THE 3RD PROJECT NO. REFERENCE ONLY. ACTUAL LAMP PARTY EQUIPMENT MAY OCCUR. CUSTOMER ASSUMES ALL RESPONSIBILITY NOTE, 1 5001 5248VLF2 AND SHIELD MAY VARY. FOR EQUIPMENT PLACED IN THESE AREAS. 7 CAS-830 CEILING STRUCTURAL DETAIL O RAD SHIELD AND LAMP WITH 4 M TRACK O CAS-830 MOVEMENT CLEARZONE SCALE: 1/4" = 1'-O" 11-06-14 SCALE: 1/2" = 1'-0" --a' 11-06-14 SCALE: 1/4" = 1'-0° 11-06-14 TYlQ CYCC'! 10 nAn-r AC A QC-! wr wsASAu■uw .. ■ —1. . - . --- ELECTRICAL LEGEND ITEM DESCRIPTON MAIN DB CB EPO BS ITEM SUPPLIED ANDI REP.NSTALLED BY CUSTOMER I CONTRACTOR MAIN MAIN SERVICE ENTRANCE PANEL E3 THREE PHASE CIRCUIT BREAKER PER TOSHIBA POWER SPECIFICATIONS (SEE DETAIL) CIRCUIT 1&5 .0 CB TO BE LOCATED BY CUSTOMER / CONTRACTOR. BREAKER LOCATION PER CODE REQUIREMENTS BY ELECTRICAL CONTRACTOR. E3 ADDITIONAL "EPO" SWITCHES TO BE LOCATED IN ADJACENT ROOMS WITH GO 18" W X 12" H X 6" D J-BOX, SURFACE MOUNTED 29 1/2"A.F.F. TO BOTTOM OF BOX. 5 TOSHIBA EQUIPMENT IF MAIN "EPO" IS NOT ACCESSIBLE (VERIFY WITH LOCAL 6 3'-5" 13'-9" OPEN TO "VR1". SEE TOSHIBA'S POWER QUALITY REQUIREMENTS FOR THE GENERATOR. E3 CODE).:ALL "EPO" SWITCHES TO BE PROVIDED BY CUSTOMER / CONTRACTOR. O o EPO 4" STD. J-BOX FOR REMOTE OFF SWITCH. LOCATED BY CUSTOMER/CONTRACTOR. ei O Qo ro DPDT, NORMALLY OPEN MUSHROOM HEAD PUSH BUTTON. E3 NOTE: _ ..__..� 8 J-BOX SIZES MAY BE INCREASED AS NEEDED .0Q WL 4" STD. J-BOX FOR "X-RAY ON" OR WARNING LIGHT MOUNTED ABOVE PATIENT ENTRY e2 WITH EXCEPTION TO THE "PCDU" J-BOX. DOOR. E3 NDTE• U 6-9 BS BUILDING STEEL. e O E3 GROMMETED OPENINGS ARE SHOWN FOR REFERENCE ONLY. VERIFY SIZE AND LOCATION C81 12" W X 12" L X 6" D J-BOX, MOUNTED UNDER FLOOR WITH 6" CORE DRILL THRU FLOOR. 1-2 WITH TOSHIBA REPRESENTATIVE. J-BOX TO HAVE REMOVABLE ACCESS COVER. S3 NOTE: C83 8" W X 16" L X 8" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. a ...I CUSTOMER HAS THE OPTION TO FURR OUT E3 WALL TO ACCOMMODATE FLUSH MOUNTED 3 WALL DUCT IF DESIRED. CAT 10" W X 10" L X 6" D J-BOX, MOUNTED UNDER FLOOR WITH 7" CORE DRILL THRU FLOOR. S3 Z2 VI N N N - m m � STORAGEI � MS 10" W X 10" L X 6" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. 4 4 C I ° y I ° W I s10 cce Z N SHARED 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD2". 3 O —I CAS-810A C-ARM E3 a ` i ROTATION ON a d F Z N AW$ p 0 /■ w p L o PHY I z z > I C830 I41- INJC SHARED 8" W.X 3" H GROMMETED OPENING IN "WD2". e o M g Z a J I E3 a L O Z a O cz F r 0 0 ZU I W W I CCB DUAL PLANE 0 INJ CONNECTS TO "PHY2". m m z '7 MIC LAB H1241 CAT i HY ON _ I Mg < o = x o _ CAT-880B TABLE CU z n INJC I.Inna ROTATION 3 Z SHARED 8" W.X 3" H GROMMETED OPENING IN WALL DUCT 'WD2". E3 a o o AWS JB7 G_+� HY O Qj INJR INJ CC1 o a o 0 �♦ D 22 CU o ¢ ¢ V �O n ,n ,n ,c SHARED 8" W X 3" H GROMMETED OPENING IN WALL DUCT 'WD2". 3 O T RSL CC2 E3 o M a d- m .7 U. M < V O O O O O n WD2 JB2 8" RAID 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD2". E3 Qo a a a a W ,J CONTROL JB1 Q INV LOCATED ON SHELF. O Y H1�@ W EQUIPMENT D - (� INV ROOM CAB �_= XTP GROMMETED OPENINGS IN "VR2 OPEN TO XTP-8100G GENERATOR CABINETS. W m _ CU H1241A I J O J85 CA I TRS 11" W X 8" L X 5" D, STEP-DOWN TRANSFORMER, TO BE LOCATED ON SHELF '■ W ~ CC2 J66 i (BY CUSTOMER/CONTRACTOR) ABOVE "PCDU" AS LONG AS LOCAL CODE ALLOWS. IIII (n W LMM AS I- MIC 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD2". J X n O-- _ JB4 CU PC1 I Q W z 0 n Z CC1 i--- LMM 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD1". E3 > W Q Co >: PC2 V Z z W J F--- RSL 6" W X 6" L X 4" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. E3 O — Z D DFP i XTP PHY1 6" W X 6" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL. FOR CUSTOMER SUPPLIED CQC J LJ (- O WL VR2 PHYSIO EQUIPMENT IN CONTROL ROOM. VERIFY CONNECTIONS/POWER W/MANUFACTURER. G a m W Y,I HY 18" W X 6" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED FLOOR. FOR CUSTOMER y V J U n RAID WD1 SUPPLIED PHYSIO EQUIPMENT AT TABLE. VERIFY CONNECTIONS/POWER W/MANUFACTURER. W Q J W W CD CUSTOMER SUPPLIED PHYSIO MONITOR ON MONITOR SUSPENSION. '� (V W 0 a/ M VR1 4" 8TRS VERIFY CONNECTIONS/POWER W/MANUFACTURER. •� z W z W JB3 16" W X 16" L X 8" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. CONNECTED TO 4 J Q � 9" JBi "CABS" XTP-810OG END CABINET VIA 6" CONDUIT OR FLEX HOSE. E3 F O ~ w B2 5'-7 1/2" J 16" W X 16" L X 6" D J-BOX, MOUNTED UNDER FLOOR WITH 6" CORE DRILL THRU FLOOR. E3 N J 0 19 - 12" W X 12" H X.4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 5 0 J83 29 1/2" A.F.F. TO BOTTOM OF BOX. OPEN TO "PCDU". E3 0 ELECTRICAL LAYOUT JB4 10" W X 10" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 24"A.F.F. TO BOTTOM OF BOX. THESE T PLANS ARE FOR INFORMATIONTION L AL PURPOSES ONLY 10" W X 10" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 24" A.F.F. AND SHALL NOT BE USED FOR 0 1' 2' 4' B' i6' TO BOTTOM OF BOX. ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER.THESE SITE JB6 8" W X 8" L X 4" D J-BOX, FLUSH MOUNT IN FINISHED CEILING. FOR CUSTOMER 4 PLANS ARE NOT 70 BE USED SUPPLIED VIDEO SIGNALS TO 58" MONITOR. E3 FOR CONSTRUCTION PURPOSES. J87 16" W X 16" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 9"A.F.F. TO 3 DATE: 05-08-15 BOTTOM OF BOX. OPEN TO "WD2". E3 ELECTRICAL DUCT LEGEND OUTLETS FOR SYSTEM TO BE LOCATED LIN EACH ROOM WHERE SYSTEM EEQUIPMENT ISELOCATED.UIPMENT. OUTLETS SCALE: 1/4" = V-0" J0 90 ITEM ITEM DESCRIPTION D RJ45 CONNECTOR, CAT5 CABLE TO BE USED FOR DATA CONNECTION FOR NETWORKING. ' CAT-SBOB TABLE l� PHYSIO BOX SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR RBF. D PLANNER: M.S. _ 18" W X 3 1/2" D FLUSH/SURFACE MOUNTED WALL DUCT, W/(3) EQUALLY PARTITIONED � RJ47 CONNECTOR, CAT7 CABLE TO BE USED FOR DATA CONNECTION FOR NETWORKING. Q WD1 COMPARTMENTS THROUGHOUT & REMOVABLE ACCESS COVERS. MOUNTED 6"A.F.F. TO E3 QUOTE: 61188-6 NO EQUIPMENT TO BE BOTTOM OF DUCT. CONNECTED TO 'VR2". �1 DEDICATED PHONE LINE SUPPLIED/INSTALLED BY CUSTOMER/CONTRACTOR. LOCATED ON HEAD-END SIDE `ti"- ' 10" W X 3 1/2" D FLUSH/SURFACE MOUNTED WALL DUCT, W/(3) EQUALLY PARTITIONED It PROJECT N0. WD2 COMPARTMENTS THROUGHOUT & REMOVABLE ACCESS COVERS. MOUNTED 12" A.F.F. TO 3 XTP-81000 GENERATOR SYSTEM COMPONENTS SUPPLIED AND INSTALLED BY TOSHIBA 7 5007 524HVLF2 BOTTOM OF DUCT. E3 2-5 I _ 10" W X 3 1/2" D SURFACE MOUNTED RISER DUCT, W/(3) EQUALLY PARTITIONED RECOMMENDED LOCATION FOR CUSTOMER SUPPLIED PHYSIO BOX AT FOOT END OF TABLE. 3 CAB SIDE COVER CABINET PC1 CAS-830B POWER CABINET NOTE: I� VR1 COMPARTMENTS THROUGHOUT & REMOVABLE ACCESS COVERS. FROM "PCDU" TO "WD1". E3 VERIFY LOCATION W/TOSHIBA REP. VERIFY CONNECTIONS/POWER W/MANUFACTURER. CAS1 CAS-830B CONTROL CABINET PC2 CAS-810A POWER CABINET 18" W X 3 1/2" D SURFACE MOUNTED RISER DUCT, W/(3) EQUALLY PARTITIONED �-�--1 - VR2 COMPARTMENTS THROUGHOUT & REMOVABLE ACCESS COVERS. FROM FINISHED FLOOR TO E3 f 87" A.F.F. OPEN TO "DFP". CAS CAS-810A CONTROL CABINET DFP DFP-8000B SYSTEM CABINET TNIC CYCCT IC DAIMT AC A CCT wr e%nAunuw m.— ....�... �.�� CEILING CONDUIT SCHEDULE CABLE KEY CONTRACTOR CONDUIT REFERENCE CABLE REFERENCE EPO MAIN BS --- OVER CEILING i Y IN/UNDER FLOOR RUN CONDUIT CONDUIT CONDUIT CABLE CABLE LENGTH CABLES CD CONTRACTOR DETERMINED NO. (POINT TO POINT) (DIAMETER) (MAX LENGTH) (POINT TO POINT) (USABLE) (SUPPLIED BY) O JB3 MS PER CODE PER CODE CD MS PER CODE CONTRACTOR •O I' 1 CB C83 PC1 DETAILR(11/E4) TOSHIBA ; SEE RUN "B" 0 FOR ABOVE CONNECTIONS, SEE DETAIL 1, SHEET E3. 2 4 C83 CAS1 DETAIL (1/E4) TOSHIBA COMBINED 36'-0" ADDITIONAL "EPO" SWITCHES TO BE LOCATED IN ADJACENT O SEE RUN "C" � C830 CAS ROOMS.WITH TOSHIBA EQUIPMENT IF MAIN "EPO" IS NOT � DETAIL (1/E4) TOSHIBA ACCESSIBLE (VERIFY WITH LOCAL CODE). ALL "EPO" SWITCHES SEE RUN "D" TO BE PROVIDED BY CUSTOMER/CONTRACTOR. C83 DFP DETAIL (1/E4) TOSHIBA ALL CABLES AND CONDUITS REQUIRED ARE TO BE PROVIDED O BY CUSTOMER/CONTRACTOR. O C83 JB4 2 1/2" 60'-O" SEE RUN "E" C83 CU TOSHIBA m r DETAIL (1/E4) _®-�----•—_----r-®-`- -_---_--s� O C83 JB4' 2 1/2" 60'-0" 83 CCi DETAIL (N/E4) TOSHIBA J 1 r O O (2) 2" 75'-0" SEE RUN "G" E 1 --•---•�-�-�-s-®---�•�-®'®!� I O5 MS JBt MS DFP DETAIL TOSHIBA 1 1 Z 1 O MS JB7 2" 80'-0" MS MIC DETAIL SEE RUN IL (i"AA" /E4) TOSHIBA y 1 W I I I O JB6 J81 2^ PER JB6 DFP PER CONTRACTOR z y 1 1 MANUFACTURER MANUFACTURER w C CCB CAS1 SEE RUN "Q" TOSHIBA �p d 1 1 1 i I i O JB7 JB1 2 1/2" 65'-0" O DETAIL (1/E4) 4t = STORAGE I ( I SEE RUN "R" H1241C 1 1 1 ( I ( CCB CAS DETAIL (1/E4) TOSHIBA w o z I I I Z � � DUAL PLANE 9 JB7 J61 3 2 1 2" SEE RUN "S" 1 1 LAB H1241 I I ( O O O O / 65'-0" CCB DFP TOSHIBA o s 4i 5 Z 1 1 DETAIL (1/E4) a o o a O F, 0 0 z I I I I ( I 10 PHY1 JB1 PER PER pHY DFP PER N 0 Tr 02 a CONTRACTOR 1 1 1 83 O O O MANUFACTURER MANUFACTURER O MANUFACTURER o Z W 0 w 11 PHY1 MS PER PER pHY HY PER CONTRACTOR 0 m y MANUFACTURER MANUFACTURER O MANUFACTURER 0 n 1 1 1 J I I o2 z - 12 JB3 RSL PER CODE PER CODE CD RSL PER CODE CONTRACTOR z N � z N LL � �I 1 1 1 I I J 0 !J Z Lu PHY1 I 13 WL JBt PER PER WL DFP PER CONTRACTOR O MANUFACTURER MANUFACTURER O O MANUFACTURER � ~ ' 3 2 I 6 11 10 � $ a o 4 o a CCB NOTE: MIC 1 A. CONDUITS SUPPLIEDIINSTALLED BY CUSTOMERICONTRACTOR. F M C ON ' 1 I - I I B. ALL CONDUIT RUNS MUST TAKE THE SHORTEST MOST DIRECT ROUTE POSSIBLE. IL C. CONDUIT IS NOT TO BE RUN IN SUCH A MANNER THAT WILL EXCEED CONDUIT MAXIMUM LENGTH ® I , AS SHOWN IN THE SCHEDULES. o 0 0 o c INJC 1 ®- �.J D. CONSULT WITH TOSHIBA INSTALLATION PROJECT MANAGER IF CONDUIT WILL BE REQUIRED TO BE �i a a a a W AWS JB7 , - I RUN IN SUCH A MANNER THAT WILL EXCEED MAXIMUM CONDUIT LENGTH SHOWN ABOVE. N —- INJR-—- ®� I I' E. CONDUITS SHOWN FOR"PHYSIO"ARE OPTIONAL AND MAY NOT BE REQUIRED FOR ALL SITES. 1 MS 5 1 I VERIFY WITH TOSHIBA INSTALLATION PROJECT MANAGER. h F. CONDUITS BETWEEN C-ARMS AND COOLING UNITS(CONDUITS 3&4)CANNOT BE RUN IN AREAS W D - RSL I HY WHERE THE TEMPERATURE DROPS BELOW 40°F.IF CONDUITS ARE RUN BENEATH SLAB OR IN —- -—` - 12 1 I EARTH,ENSURE GROUND TEMPERATURE DOES NOT DROP BELOW 40-F. w m II T I 1 i ( G. CONDUITS MARKED WITH AN"" REQUIRED EXTENDED CABLES(SEE DETAIL 1,SHEET E4). J O ' - - - I I FINAL LENGTH OF CONDUIT TO BE DETERMINED IN FIELD BY I.P.M. cn W W H ' WD2 " J 17 CAB i I I j X CD O I ROOM ' I H, 4 ' ' I a W z 0 Io Z 1 ' I I I I V Z Z O --- Z ' 1 ' EQUIPMENT � � � � W � � I I ! JB5 CU H ROOM ' CAS1 i--- I I W C CC2 1241 I I I 7 AS I 1 ' H--- � Q m Z J W CU JB6 Q J V JB4 LMM 1 PC1. I I I W Q J W a W 6 CCi H--- 1 1 , .�.� PC2 ' W L L--- --- 3 Q 0 UJ D DFPLu J iWL VR2 I J co I Q � RAID CD WD1 ( I Q 0 II VR7 TRS I I ( I � 1 THESE TOSHIBA PLANS ARE FOR I L---_---_-®----_®--------•-JB3_�, ---_--_---_---� I INFORMATIONAL PURPOSES ONLY L AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT AGANDTHEREED U CUSTOMER.THESE SITE BETWEEN TOSHIBA �- -_- -_----"- -®"- "--- ----- "- ®-- -'��`j PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. DATE: 05-08-15 SCALE: 1/4" = l'-O" 0 CEILING ELECTRICAL SCHEMATIC PLANNER: M.S. (PROVIDED FOR REFERENCE PURPOSES ONLY) QUOTE: 61188-6 o 1' 2' a' a tTr PROJECT NO. 150015248VLF2 THIS SHFFT IC PANT AC A CGT AC n0Aw1w11/i n0%A-1IRRruTL- Ac• 1 ■c11-0-111% 0%u FLOOR CONDUIT SCHEDULE CABLE KEY CONTRACTOR CONDUIT REFERENCE CABLE REFERENCE EPO MAIN BS OVER CEILING IN/UNDER FLOOR RUN CONDUIT CONDUIT CONDUIT CABLE CABLE LENGTH CABLES CD CONTRACTOR DETERMINED NO. (POINT TO POINT) (DIAMETER) (MAX LENGTH) (POINT.TO POINT) (USABLE) (SUPPLIED BY) SEE 810 PC2 DETAIL (11/E4) TOSHIBA l CB O 55'-0" C81 CAS TOSHIBA 14 C81 J62 COMBINED DETAILSEE R(1,/E4) NOTES: SEE RUN "J" O FOR ABOVE CONNECTIONS, SEE DETAIL 1, SHEET E3. C81 DFP TOSHIBA DETAIL (1/E4) ADDITIONAL "EPO" SWITCHES TO BE LOCATED IN ADJACENT O O 2 1/2" 70'-0' SEE RUN "K" 15 C81 JB5 C81 CU ROOMS WITH TOSHIBA EQUIPMENT IF MAIN "EPO" IS NOT DETAIL (1/E4) TOSHIBA ACCESSIBLE (VERIFY WITH LOCAL CODE). ALL "EPO" SWITCHES to SEE RUN "L" TO BE PROVIDED BY CUSTOMER/CONTRACTOR. i6 C810 JB5 2 1/2" 70'-0" C810 CC2 TOSHIBA .� DETAIL (1/E4) ALL CABLES AND CONDUITS REQUIRED ARE TO BE PROVIDED BY CUSTOMER/CONTRACTOR. 17 CAT JB7 2 1/2" 28'-0" CAT CCB SEE RUN "M" TOSHIBA DETAIL (1/E4) 40 SEE RUN "0" J CAS1 i8 CA7 J82 2 1/2" DETAIL (1/E4) TOSHIBA COMBINED 45-0" CAT SEE RUN "P" CAT CAS DETAIL (1/E4) TOSHIBA z 19 CAT J62 2" & 2 1 2" O O SEE RUN "N" _ / 49'-0" CAT DFP DETAIL (1/E4) TOSHIBA 20 HY PER PER PHY1 HY PER z L PHY1O MANUFACTURER MANUFACTURER CONTRACTOR O MANUFACTURER 0 Qa p 2 21 HY JB7 2" PER INJ INJR PER !NTRA'CTOR z a OMANUFACTURER MANUFACTURER w 0 - z CAT JB72" 42'-0" CAT CCB SEE RUN "M" OSHBA d > pw STORAGE O O DETAIL (1/E4) w O p O - p z p H1241C o a w 81 NOTE: a o o ga v_i O ---—- —--—-- - A. CONDUITS SUPPLIED/INSTALLED BY SHORTEST MOST DIRECT . v U Z 0 N vi B. ALL CONDUIT RUNS MUST TAKE THE SHORTEST MOST DIRECT ROUTE POSSIBLE. w � � 0 � � w �"■ C. CONDUIT IS NOT TO BE RUN IN SUCH A MANNER THAT WILL EXCEED CONDUIT MAXIMUM LENGTH C' Z o y v AS SHOWN IN THE SCHEDULES. U w N D. CONSULT WITH TOSHIBA INSTALLATION PROJECT MANAGER IF CONDUIT WILL BE REQUIRED TO BE p m m Z - I RUN IN I SUCH A MANNER THAT WILL EXCEED MAXIMUM CONDUIT LENGTH SHOWN ABOVE. i,,l N O O li E. CONDUITS SHOWN FOR"PHYSIO"ARE OPTIONAL AND MAY NOT BE REQUIRED FOR ALL SITES. z N z ^ z0 PHYI --—-- , VERIFY WITH TOSHIBA INSTALLATION PROJECT MANAGER. F y F. CONDUITS BETWEEN C-ARMS AND COOLING UNITS(CONDUITS 15&16)CANNOT BE RUN IN AREAS p p z p WHERE THE TEMPERATURE DROPS BELOW 40-F.IF CONDUITS ARE RUN BENEATH SLAB OR IN I EARTH,ENSURE GROUND TEMPERATURE DOES NOT DROP BELOW 40-F. C 2p i G. CONDUITS MARKED WITH AN"""REQUIRED EXTENDED CABLES(SEE DETAIL 1,SHEET E4). m C, m O p O CCB I I • FINAL LENGTH OF CONDUIT TO BE DETERMINED IN FIELD BY I.P.M. ,n in ,a v, ,n MIC G - D7 CAT M < a I ro m ON I i p n o 0 0 0 0 0 INJC r---- -----------, a a a a a a y AWS J87 Lu 0 - ' ■ - INJR D -17 22-- 2 HY 18 14 15 INJ ^ W 1s 1s U m T 2 - LL_I WD2 DUAL PLANE J O Li n LAB 111241 W cn LW H ,J) CONTROL J82 QI I I j X �j o O ROOM > F. LL_ o 00 y, INV CU CAB _V Z Z J85 EQUIPMENT CAS1 I ' I Z CC2 ROOMH11241A AS c A z J W --- I a Q J J V "--CU LMM Pc1 I {y J W Q I LL- J134 L LJ J W cci Pc2 I ( z 0 z W DFP — Lu RAID i XTP I— O VR2 i I Q 00 O CD WD1 Q U. i VR1 I � THESE PLANS TRS , JB3 FOR INFORMATIONALTOSHIBA PURPOSESEONLY L""� - -"-���- -------- --------� AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER.THESE SITE PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. 0 FLOOR ELECTRICAL SCHEMATIC DATE: 05-08-15 (PROVIDED FOR REFERENCE PURPOSES ONLY) SCALE: 1/4" 0 1' 2• 4- 8- 'Is' PLANNER: M.S. QUOTE: 61188-6 PROJECT NO. 150015248VLF2 'rUIQ Q41CC'T IC DA12T AC A CC7- AC e1n A%AI■s■w 1110%/�111■wwru�n we. ■ ■e...mow w.. .�..��w w� �..w ....�... -.�� ______--_ � I CABINET ABLES CONNECTING FROM THE CONTRACTOR ITT IINOTS RECOMMENDED THAT CONTRACTOR PROVIDED POWER QUALITY REQUIREMENTSwINSIDE EQUIPMENT ROOM �'--- PROVIDED BY TOSHIBA --- . IED RELAY CIRCUITS TO THE SYSTEM TRANSFORMER RELAYS BE LOCATED IN CEILING ABOVE TOSHIBA INFINIX WITH PCDU-100VL �� IF POSSIBLE i( ) ARE TO BE SUPPLIED BY THE CONTRACTOR. XTP-81000 SYSTEM TRANSFORMER CABINET. , SUPPLY CONFIGURATION: DELTA OR WYE r_ "MTW" OR WELDING ' KVA RATING: 150.00 C DFP-8000 SYSTEM PROVIDED BY CONTRACTOR ( ) M 'r~ I TYPE CABLE , SYSTEM CONTROLLER CABINET i rr--�---�----"'-'-""" ""-------""""-`--. VOLTAGE SEE NOTE B: 480V, 60Hz W I MAIN SERVICE I SHUNT TRIP , CNN PANEL TB i i i CALCULATED CURRENT (AMP): 180.42 ENTRANCE PANEL i CIRCUIT BREAKER PCDU CIRCUIT BREAKER AMP SEE NOTE F: 100 , , POWER SUPPLY (AMP) ( ) , I ' S 5 C 12V OR 24V i % IMPEDANCE: 5.00 ^ AC IN POWER LINE RESIST. SPEC.: 0.000 I 3 POLE 80 AMP --- --- DFP :...........: OV SOURCE MAXIMUM CURRENT (AMPS): 180.42 OV 6 6 VOLTAGE DROP (VOLTS): 24.00 cm I 1 POLE 15 AMP --- --- LAMP LINE RESIST. (OHMS): 0.133 480V, 3 POLE ^ ROOM LIGHT O K2 JP ' CONTROL LINE DROP (PERCENT): 1.50 I 2 POLE 15 AMP --- --- AUX 2_ 10 10 ; Ry Ry LINE DROP (VOLTS): 7.20 I 480V, 100 AMP CONDUCTOR (OHMS): 0.040 ROOM , G i G G 2 POLE 15 AMP --- --- AUX ; LIGHT TEMPERATURE: 68-F (20'C) J i 11 11 ; CONDUCTOR SIZES OHMS PER TEMP 1 POLE 15 AMP --- --- AUX i ; (SEE NOTE E) 1000 Fr. DERATED NEC 75'C LENGTH (FT.) K3 ' 3 AWG 0.2540 0.2089 100 96 1 POLE 15 AMP --- --- AUX ; 12 12 Ry Ry L 2 AWG 0.2010 0.1653 115 121 GROUND SOURCE , PER ; SURGICAL ' 1 AWG 0.1600 0.1316 130 152 _ETOPTIONAL --- --- y NEC SECTION 250 � LIGHT i 1 POLE 15 AMP INJECTOR , SURGICAL 1/0 AWG 0.1270 0.1044 150 191 W 13 13 LIGHT 2/0 AWG 0.1010 1 0.0831 1 175 (1)240 Q WIRES PER CODE TO 1 POLE 30 AMP]---..--- DFP ; i PCDU MAX INPUT LUG SIZE 2 0 AWG 0 SHUNT TRIP PUSH BUTTON. / EMERGENCY POWER CL OFF 1 POLE 15 AMP --- --- AUX 8 8 Ry RY L d "EpQ" ' X-RAY ON w PUSH BUTTON 2 POLE 50 AMP --- --- DIGITAL 1 LIGHT X-RAY ON o a W Z SHUNT TRIP PUSH BUTTON IN ' 9 9 a v z C 2 POLE 70 AMP --- --- DIGITAL 2 ; N CONTROL AREA W/ A NORMALLY OPEN CONTACT (IF REQUIRED). w , o 1 POLE 15 AMP --- --- RECEPTACLE ; ----' Ry Ry L 3 I- ' ........ ; m w �ADDITIONAL "EPO" SWITCHES TO BE SYSTEM ON w LOCATED BY CUSTOMER/CONTRACTOR NEUTRAL-GROUND BONDING, 11` NEEDED. CHASSIS BONDING, ' LIGHT Z N n & GROUND ELECTRODE ....................................................r .......................................... r li ...................................................-r J O Z Z CONNECTION ARE FACTORY = 0 CONNECTED. g w = CONNECTING THE RELAY TO THE DFP-8000• PRECAUTIONS IN WIRING: o 0 o¢ z V A. IN THE CIRCUIT DIAGRAM ABOVE, THE EXTERNALLY CONNECTED 12V RELAY IS DRIVEN VIA C. ISOLATE THE RELAY COIL AND THE CONTACT CABLE. THIS MAY REDUCE THE IMPACT FROM z THE RELAY CONTACT OF THE DFP-8000 AND THE 12V RELAY CONTROLS THE SWITCH EXTERNAL NOISE AND ENSURE ELECTRICAL ISOLATION. IN ADDITION, CONNECT t2 tO ce 0 CONNECTED TO THE POWER CIRCUIT. TWISTED-PAIR CABLES TO THE CONTACT AND THE COIL. THIS MAY ALSO REDUCE THE EQUIPMENT GROUNDS OCCURRENCE AND IMPACT OF NOISE. o a B. BE SURE TO INSTALL DIODES TO THE RELAY COILS FOR ABSORBING SURGES. IF A SURGE U. CAUSED BY A COUNTER-ELECTROMOTIVE FORCE OCCURS, AN ERROR MAY OCCUR IN THE RELAYS D FOR TURNING ON/OFF THE ROOM HT AND WARNING o 0 o Q GROUND ELECTRODE PER NEC 250-30(A) DFP-8000. USE A DIODE WITH A RATING OF 1000V AND 1A FOR ABSORBING SURGES D. FOR THE CONTROL CIRCUIT OF THE ROOM LIGHT OPEN/CLOSE SWITCH, USE THE POWER a a a W BUILDING STEEL, WATER PIPE, OR GROUNDING ELECTRODE AS CLOSE AND USE A DIODE WITH A RATING OF 2000V BETWEEN THE COIL AND THE CONTACT. SUPPLY ISOLATED FROM THE ROOM LIGHT CABLE. IF THE ROOM LIGHT CIRCUIT IS Lu AS PHYSICALLY POSSIBLE TO THE DISTRIBUTION UNIT. GROUND DIRECTLY CONNECTED TO THE RELAY CONTACT CONNECTED TO THE DFP-8000,-NOISE MAY STANDARD POWER QUALITY NOTES U CONDUCTORS MUST BE SAME SIZE AS PHASE CONDUCTORS. EASILY ENTER DEPENDING ON THE ROUTING. TO PREVENT SPARKS FROM OCCURRING AT THE RELAY CONTACT, INSTALL APPROPRIATE SNUBBER CIRCUITS TO THE SWITCH COIL. ppuu �y� �� H- W A. THERNEUTREAOL CONDUCTOR MAY SNOT BE IS A TO SYSTEM. EQUIPMENT OPERATION. w Lb B. IN CASES WHERE MULTIPLE VOLTAGES ARE PERMITTED,THE PREFERRED SYSTEM VOLTAGE EIS SPECIFIED. ` J 0 C. DUE O TAGE TSOURCE IENSURENTHAT LOWERR VOLTAGE SOURCESI ARE DERIVED DSRECTLY FIROMSTHEV SERVICE r w (n CS / PCDU-100VL WIRING DETAIL O ELECTRICAL LIGHTING CONNECTIONS DIAGRAM ENTRANCE OF THE FACILITY. W � w F D. GROUND CONDUCTORS ARE RE%UIRED TO BE THE SAME SIZE AS THE PHASE CONDUCTORS UNLESS A >SCALE: NOT TO SCALE 11-06-14 SCALE: NOT TO SCALE 11-06-14 LARGER SIZE IS REQUIRED BY ODE. J X > O- O E. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS MUST BE COPPER -ALUMINUM IS NOT PERMITTED. a W z Q ro Z NOTE: F. IF THE EQUIPMENT CIRCUIT BREAKER IS NOT LOCATED IN THE CONTROL AREA A SHUNT TRIP BREAKER > F E Q 00 MUST BE USED IN ORDER TO COMPLY WITH N.E.C. 517-72(B). A PUSH-BUTTON TO OPERATE THE CUSTOMER'S CONTRACTOR TO VERIFY LOCATION ..�� SHUNT TRIP MUST BE LOCATED IN THE CONTROL AREA. (� Z Z � r OF J-BOX(ES) FOR CABLE PULL TO WALL DUCT. � — � 0 Z - CUSTOMER'S CONTRACTOR TO VERIFY LOCATION "�' / ' G. A SEPARATE CIRCUIT FED FROM THE FACILITY RADIOLOGY PANEL OR A MAIN SERVICE PANEL IS I^ W — OF GROMMETED OPENINGS IN WALL DUCT WITH ./!~ ,/'! PERMITTED,USE OF A SUB PANEL WITH LOADS SUCH AS ELEVATORS, HVAC, MOTORS, ETC., IS NOT O TOSHIBA REP. �.�j'". �"r .' H. DEVICES SUCH AS UNINTERRUPTIBLE POWER SUPPLIES POWER CONDITIONERS VOLTAGE REGULATORS J z (n C 6" AND FILTERS MAY BE INCOMPATIBLE y ITH THIS IMAGINb EQUIPMENT. CONSULT'YOUR TOSHIBA SERVICE GROMMETED OPENING OR / REPRESENTATIVE PRIOR TO PURCHASING OR INSTALLING THESE DEVICES. Q m J J W SPLIT ACCESS COVER ON SURFACE MOUNTED WALL CONDUIT(S) ABOVE �♦ J V FACE OF WALL DUCT. DUCT WITH EQUALLY �` SURF E X 6" J-BOX, I. THE MAINS POWER GROUND CONDUCTOR IS TO BE RUN WITH THE POWER PHASE CONDUCTORS. THE y V SPACED PARTITIONS i I FINISHED CEILING. SURFACE MOUNTED TO WALL. GROUNDS TO BUILDING STEEL OR EARTH GROUND ARE NOT TO BE RUN WITH THE PHASE CONDUCTORS. W Q � J W NOTE: CUT UTS AT OOUGHOUT PENINGS ION Y z J-BOX FLUSH MOUNTED W W O Lu 45' SECTION IN FINISHED CEILING. 12" X 12" X 4" J-BOX, CC z _ FLUSH MOUNTED IN WALL. J G Q 0- W MAY OCCUR FOR ALL WALL NOTE: J f LL DUCT CORNERS. SEE ELECTRICAL DUCT ! SYSTEM DAMAGE MAY OCCUR W LEGEND (SHEET E1) FOR ` may REMOVABLE COVER. 10" W X 3 1/2" D, SURFACE 200% ABOVE (DAMAGING IMPULSES) F- C NUMBER OF EQUALLY --- MOUNTED VERTICAL RISER DUCT. NOMINAL VOLTAGE N �' SPACED PARTITIONS WITHIN -J 0 DUCT (THREE SHOWN FOR r 18" W X 3 1/2" D, SURFACE 0 }_ REFERENCE). I\ .. MOUNTED WALL DUCT. LL. J-BOX FLUSH MOUNTED IN FINISHED CEILING SYSTEM DI/ . k FNLU H MOUNTED J-BOX _7 (DISRUPTIVESTEM DAMAGE MAY OCCUR ,I, r _ 100% ABOVE ( THESE TOSHIBA PLANS ARE FOR (OPEN TO WALL DUCT) CORE DRILL THRU FLOOR. IGH VOLTAGE, SWELLS, & SURGES INFORMATIONAL PURPOSES ONLY "PCDU" NOMINAL VOLTAGE ) AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT J-BOX SURFACE MOUNTED AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE GROMMETED TO UNDERSIDE OF FLOOR. PLANS ARE Nor TO BE USED OPENING LOCATED `� ��. I 1 FOR CONSTRUCTION PURPOSES. ON BOTTOM FACE OF WALL DUCT. �'� � a 10% ABOVE NOMINAL DATE: 05-08-15 i NOMINAL VOLTAGE ----------------------------- -------e-------------------------- CONDUIT(S) BELOW FLOOR. SCALE: NOT TO SCALE ram. v r tO -10% BELOW NOMINAL ACCEPTABLE VOLTAGE RANGE SYSTEM DISRUPTION MAY OCCUR PLANNER: M.S. (LOW VOLTAGE, SAGS, & OUTAGE) REMOVABLE COVER. QUOTE: 61188-6 REMOVABLE COVER ON UNDERSIDE OF X. NCDU-lOOV1_" TE, PROJECT NO. GGESTED MOUNTING OF J-BOX FOR 10 NS lops 1 mS 10 mS looms 1 Sec 1 Min 1 Hr 150015248VLF2 J-BOX SURFACE MOUNTED UNDER FLOOR OR AS PER LOCAL CODE. TYPICAL DUCT DETAIL WITH 3 LSTLE�: NOT L DUCT/J-BOX /VERTICAL RISER O TYPICAL J-BOX DETAILS O TYPICAL PCDU J-BOX MOUNTING 6 POWER REQUIREMENTS WITH PCDU TO SCALE 11-06-14 SCALE: NOT TO SCALE 11-06-14 SCALE: 1" = 1'-O" 11-06-14 O SCALE: NOT TO SCALE 11-06-14 TYIC CYCCT 10 nApT AC A Qc-r we 11%1MAunu0ft www..RJIIII�u�s M.. _--- NOTE: A. THE FOLLOWING CABLE DIAGRAM IS FOR REFERENCE ONLY AND MAY.NOT CONTAIN THE EXACT EQUIPMENT w SHOWN IN THE ATTACHED DRAWING PACKAGE. B. I.P.M. IS RESPONSIBLE FOR ENSURING THAT CABLE ., LENGTHS MEET THE SITE CONDITIONS. THE I.P.M. IS O ,. •.: c RESPONSIBLE FOR ORDERING THE REQUIRED CABLES O TO MEET EXISTING/PROPOSED SITE CONDITIONS. •0 ---+---�--- ,_ C. THIRD PARTY ITEM CONNECTIONS TO BE VERIFIED WITH INSTALLATION PROJECT MANAGER. , D. POWER AND SIGNAL CABLES MUST BE RUN IN O ---- It SEPARATE CONDUIT. REFER TO SHEET E2. POWIR MIC ESD CCB C83 C81 CAT MS CAS1 CAS PC1 PC2 DFP RAID INV CU CC1 CU CC2 SYSTEM r RUN CONNECTION LTR. (POINT TO POINT) REMARKS O A "C830" T "PC1" (55'-9") - (HIGH VOLTAGE) EXTENDED CABLES NOT AVAILABLE J - "C830" T "CAS1" (46'-3") - (POWER) • - - C83 PC1 (HIGH VOLTAGE CABLES) B EXTENDED CABLES ARE NOT AVAILABLE "C830" T "CAST (46'-3") - (SIGNAL) K C EXTENDED CABLES ARE NOT AVAILABLE y "C830" T "DFP" (88'-7") (SIGNAL & POWER) „_ D -.. ---_- EXTENDED CABLES ARE NOT AVAILABLE u "C830" T "WGL1" (75'-0") - (COOLANT) E -.. i_--- EXTENDED HOSES NOT AVAILABLE O F "C830" T "CC1" (75'-0") - COOLANT) OE C83 CU (COOLING HOSES) j F EXTENDED HOSES NOT AVAILABLE OF C830 CC1 (COOLING HOSES) IL 6 "MS" TO "DFP" (78'-8') - (SIGNA & POWER) z w G - -- ---- """""" -_- -- GO MS DFP EXTENDED CABLES ARE NOT AVAILABLE w N Z "C810" TO "PC2" (72'-0") - (HIGHVOLTAGE) 1 - - _— - O a O r H EXTENDED CABLES ARE NOT AVAILABLE c�i U z = t O O (HIGH VOLTAGE CABLES) x o z w o O C810" TO "CA52" (65'-7") - (SI NAL & POWER) O C61 CAS EXTENDED CABLES ARE NOT AVAILABLE o ~om o "C810" TO "DFP" (88'-7") - (SIGNAL & POWE ) ow M EXTENDED CABLES ARE NOT AVAILABLE z N w N "calo" To "Wcu2" (75'-0") - (c OLANT) a Z K - EXTENDED.HOSES ARE NOT AVAILABLE OK C81 CU (COOLING HOSES) w O - o "C810" 0 - - K o T 'CC2" 75' 0" CO LANT o L ( ) ( ) EXTENDED HOSES ARE NOT AVAILABLE a Z V CC2 "CCB" TO "CAT" (52'- ") IVUS (38-2") (COOLING HOSES) t2 � - (SIGNAL) t w I I I ----M -- -- - O 101'-8" MAX. SYSTEM CABLE 00 0- 38'-2" MAX IVUS "CAT" TO 'DFP" (59'-0") (SIGNAL & POWER) .i • o 0 o W N — THIS CABLE GROUP CAN MAX.- ON CAT DFP EXTENDED TO 75'-5" . N "CAT" TO 'CAS1 (55 9") (SIGNAL & POWER OO CAT CAS1 EXTENDED TO OUP MAX. ^ 0 -- __._ -- .___ THIS CABLE GROUP CAN BE "CAT" TO CAS2" ( )55' 9' GNAL) ( W P (SIGN "•4 OP CAT CAS THIS CABLE GROUP CAN BE 0 m EXTENDED TO 108'-3" MAX. Li O "CCB" TO "CASs" (85' 3") - (SIG AL) J - Q THIS CABLE GROUP CAN BE (Ld f) cn "CCB" TO "CAS2" (88' 7") - (SIGNAL) EXTENDED TO 101'-8" MAX. W (n W : R EXTENDED CABLES ARE NOT AVAILABLE J X_ � PO O S "CCB" TO "DFP" (75'- ") - (SIGN L & POWER) ,u Q W Z Z U+ ijo EXTENDED CABLES ARE NOT AVAILABLE > I- LL Q �Z p"DFP" Ti! O "POWER SYS EM" (22'-1 ") - (POWE ) V J TT DFPPOWER THIS CABLE GROUP CAN BE W — 0_ Z' O O SYSTEM EXTENDED TO 55'-9" MAX. O O Z "DFP" TO "WCU1" (65' 7") - (N/ ) Q W O U OU DFP CU EXTENDED CABLES ARE NOT AVAILABLE Z J W i "DFP" TO "CC1" (42'- ") - (SIGNFIL & POWER y O J -1 V V OV DFP CC1 EXTENDED CABLES ARE NOT AVAILABLE W — W LL Z "DFP" TO "WDU2" (65' 7") - (N/A) 0 J W W WO DFP CU EXTENDED CABLES ARE NOT AVAILABLE ' CCW z p Z 19 "DFP" TO "CC2" (42'- ") - (SIGNAL & POWER J G W X OX DFP CC2 EXTENDED CABLES ARE NOT AVAILABLE W J Y "DFP" TO "INV" (29'- ") - (SIGNA) THIS CABLE GROUP CAN BE y CD O O �"ESD" TO "DFP" (78'-8") - (SIGN EXTENDED TO 29'-6" MAX. � �EXTENDED CABLES ARE NOT AVAILABLE {L "MIC" TOS" (95'-1') - (SIGNAL) AA ---- BB . O MIC MS EXTENDED CABLES ARE NOT AVAILABLE t ( ') - (SIGNAL & POWER FOR NFORMATTONAL PURPOSES THESE TOSHIBA PLANS EONLY "DFP" TO "RAID" 42' 7' THIS CABLE GROUP CAN BE AND SHALL NOT BE USED FOR BB DFP RAID EXTENDED TO 91'-10" MAX. ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER.THESE SITE PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. DATE: 05-08-15 SCALE: NOT TO SCALE PLANNER: M.S. QUOTE: 61188-6 PROJECT NO. 150015248VLF2 7 CABLE LENGTH DIAGRAM (FOR INTERNAL USE ONLY) SCALE: NOT TO SCALE 11-06-14 T411S CYCCT IC OAO7• d%V A CCT 0%IT 1%MAunKNfW n0%0.0•wwI�-1111,111�c Ac. 0 ■�- O m > O M2 O J -zl F U U Z Q1 m J J N W co a a o � w � w O_ z Aw— x O c.> o N_ CD w Of 3 o V o z o a J L Z_ Iw LL q N Q _ z ZN O o a t� O o LL M N O O Q w Q Q W H 7 N W m ~ O J w W f. ..1 � L � n O Q W O � (n Cl COVER SHEET W vJ z J z Q 0 GN GENERAL NOTES � G Lu W m oz SECTION A J ` g ° U. Al EQUIPMENT LAYOUT H _o o ~ A2 EQUIPMENT ELEVATIONS °o Q: A3 EQUIPMENT ELEVATIONS 0 A4 EQUIPMENT SCATTER RADIATION DIAGRAMS LL THESE TOSHIBA PLANS ARE FOR SECTION S INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR ANV PURPOSE OTHER THAN THAT Sl FLOOR SUPPORT LAYOUT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE S2 CEILING SUPPORT LAYOUT PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. S3 FLOOR STRUCTURAL DETAILS DATE: 05-13-15 S4 CEILING STRUCTURAL DETAILS SCALE: NOT TO SCALE SECTION E PLANNER: L.B.C. E1 ELECTRICAL LAYOUT E2 ELECTRICAL SCHEMATICS SID: 30027352 E3 ELECTRICAL DETAILS / POWER QUALITY REQUIREMENTS PROJECT NO. E4 CABLE LENGTH DIAGRAM (FOR INTERNAL USE ONLY) 150015249VLF1 r �� = MINIMUM SITE REQUIREMENTS CHECKLIST GENERAL NOTES STRUCTURAL NOTES ELECTRICAL REQUIREMENTS PROJECT: SITE INSPECTION DATE: CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. CUSTOMER/CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. FOR I N FI NIX SYSTEM WITH PCDU-100VL GENERA A. THESE SITE PLANS ARE INTENDED TO DEPICT ONLY A CONCEPT OF THE STRUCTURE _ EQUIPMENT DELIVERY DATE: INSPECTED BY: A. TOSHIBA RESERVES THE RIGHT TO CHANGE THESE DESIGNS AND SPECIFICATIONS REQUIRED FOR THE TOSHIBA EQUIPMENT. THE DESIGN OF ALL STRUCTURAL ELEMENTS WITHOUT NOTICE. - MUST BE SPECIFIED BY A LICENSED STRUCTURAL ENGINEER IN ACCORDANCE WITH ( .. IN ORDER TO ENSURE A TIMELY AND SUCCESSFUL INSTALLATION, IT IBA BY SS HAVING TO TOSHIBA SPECIFICATIONS AND ALL APPLICABLE CODES. SUPPLY CONFIGURATION: 3 PHASE DELTA OR WYE COMPLETE THIS FORM PRIOR TO INSTALLATION. PLEASE ASSIST TOSHIBA BY HAVING THE B. THE CUSTOMER/CONTRACTOR IS RESPONSIBLE TO ENSURE THAT ALL APPLICABLE CONTRACTOR OR YOUR REPRESENTATIVE COMPLETE THE FOLLOWING: FEDERAL, STATE, AND LOCAL CODES AND ORDINANCES ARE COMPLIED WITH. B. THE CUSTOMER/CONTRACTOR SHALL FIELD VERIFY ALL EXISTING AND PROPOSED 125 kVA 1' C. PRIOR TO EQUIPMENT DELIVERY AND INSTALLATION, THE SITE MUST BE 100% SUPPLY VOLTAGE: 480V - 100AMP a ALL WALLS, FLOORS, AND CEILINGS FINISHED. WALLS PAINTED, FLOORS TILED, C DIMENSIONS AND SITE CONDITIONS PRIOR TO COMMENCING CONSTRUCTION. AND CEILING GRID WORK AND FIXTURES INSTALLED. COMPLETE, CLEAN AND FREE OF DUST. CUSTOMER/CONTRACTOR AND TOSHIBA C. THE TOSHIBA INSTALLATION PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY 11-06-14 m 2. MONOLITHIC OR LAY-IN CEILING? PLEASE CIRCLE ONE. INSTALLATION PROJECT MANAGER MUST COMPLETE A SITE WALK THROUGH 1 WEEK FIELD CONDITIONS ENCOUNTERED THAT ARE CONTRADICTORY TO THOSE SHOWN IN THE _E_LECTRICAL NOTES PRIOR TO DELIVERY AND DETERMINE ACCEPTABILITY FOR DELIVERY. TOSHIBA SITE PLANS. C DOORS AND WINDOWS INSTALLED AND LOCKABLE. DOORS TO BE REMOVED 3' PRIOR TO DELIVERY BY CUSTOMER OR CONTRACTOR AND REINSTALLED AFTER D. ANY CABINETRY THAT MAY BE REQUIRED TO HOUSE VIDEO RECORDERS, MONITORS D. THE DEMOLITION, FABRICATION, AND ERECTION OF SUPPORT STRUCTURES FOR TOSHIBA CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. C EQUIPMENT MOVE-IN. RESERVE SECURE ROOM FOR STORAGE DURING KEYBOARDS, OR OTHER ANCILLARY EQUIPMENT SHALL BE SUPPLIEDAND INSTALLED EQUIPMENT SHALL BE PERFORMED BY THE CUSTOMER/CONTRACTOR IN ACCORDANCE A. THESE SITE PLANS ARE INTENDED TO DEPICT ONLYA.CONCEPT OF THE ELECTRICAL = L� INSTALLATION. BY CUSTOMER/CONTRACTOR. WITH THE DESIGN AND SPECIFICATIONS SET.FORTH BY THE STRUCTURAL ENGINEER OF REQUIREMENTS FOR THE TOSHIBA EQUIPMENT. THE DESIGN OF ALL ELECTRICAL AREA SET ASIDE FOR EQUIPMENT RIGGING AND MOVE-IN. ENVIRONMENTAL E. PROVIDE ADEQUATE VENTILATIONRECORD. ELEMENTS MUST BE SPECIFIED BY A LICENSED ELECTRICAL ENGINEER IN ACCORDANCE WITHIN CABINETRY AND INSTALL AXIAL FANS ON THE WITH TOSHIBA SPECIFICATION AND ALL APPLICABLE CODES. _ 4, ISSUES ADDRESSED AND RESOLVED PRIOR TO EQUIPMENT DELIVERY (I.E. TOP, SIDE, OR BACK OF CABINETS, IF REQUIRED. E. DUE TO THE DYNAMIC NATURE OF THE LOAD, BOTH HORIZONTAL AND VERTICAL SURGICAL SUITE). ACCELERATION SHOULD BE INCLUDED IN THE DESIGN-CALCULATIONS FOR THE SUPPORT B. IN ACCORDANCE WITH NEC ARTICLE 517-72(B), THE EQUIPMENT CIRCUIT BREAKER(S) STRUCTURE AS WELL AS ANCHORING AND THRU-BOLTING FOR THE TOSH18A EQUIPMENT. MUST BE LOCATED SO THAT THEY SHALL BE OPERABLE FROM A LOCATION READILY F. THESE TOSHIBA SITE PLANS DO NOT INDICATE EQUIPMENT REQUIREMENTS FOR ITEMS 5. EQUIPMENT (INGRESS) ROUTES ARE CLEAR AND OBSTACLE FREE. NOT SOLD BY TOSHIBA SUCH AS, PHYSIOLOGICAL MONITORS, LASER CAMERAS, ACCESSIBLE FROM THE CONTROL AREA. IF THIS IS IMPOSSIBLE OR IMPRACTICAL, THE O INJECTORS, ETC. SPECIFICATIONS FOR THOSE ITEMS MUST BE OBTAINED FROM THE F. IN THE INTEREST OF SAFETY, TOSHIBA RESERVES THE RIGHT TO DELAY INSTALLATION USE OF A SHUNT TRIP TYPE BREAKER WILL BE NECESSARY TO SATISFY THIS ALL CONDUIT,GROMMETED LNG (WITH COVERT), AND BOXES INSTALLED (CLEAN AND VENDOR AND INCLUDED IN THE DESIGN TOTALS. COMMENCEMENT UNTIL STRUCTURAL DESIGN DRAWINGS STAMPED BY THE STRUCTURAL REQUIREMENT. THE EMERGENCY OFF BUTTON FOR THE SHUNT TRIP SHOULD BE 6. DUST FREE). GROMMETED OPENINGS, CHASE NIPPLES, RACEWAY DIVIDERS, ETC. ENGINEER OF RECORD HAVE BEEN PROVIDED. LOCATED IN THE CONTROL AREA. ...I COMPLETE. G. DESIGN, FABRICATE, AND INSTALL MEDICAL GAS PEDESTAL, IF REQUIRED. CONSULT 7 CIRCUIT BREAKER INSTALLED AND INCOMING POWER (PER POWER QUALITY WITH TOSHIBA INSTALLATION PROJECT MANAGER FOR SUITABLE LOCATIONS. CEILING STRUCTURAI SYSTEMS C. THE CUSTOMER/CONTRACTOR SHALL SUPPLY AND INSTALL ALL CIRCUIT BREAKERS, G. IN ORDER TO AVOID COLLISION WITH MOVEABLE TOSHIBA CEILING MOUNTED EQUIPMENT, CONDUITS, JUNCTION BOXES, DUCTS, ETC. SPECIFIED HEREIN. REQUIREMENTS) OPERATIONAL AND CONNECTED TO ROOM BREAKER(S). H. CUSTOMER/CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AN OPERATING ALL CEILING FIXTURES SUCH AS LAMPS, SMOKE DETECTORS, SPRINKLERS, ETC. MUST BE PHONE IN THE CONTROL ROOM AT THE TIME TOSHIBA EQUIPMENT INSTALLATION FLUSH-MOUNTED. 8. LOCATION OF ALL ELECTRICAL BREAKERS IN POWER CHAIN NOTED. BEGINS. D. THE TOSHIBA SITE PLANS DO NOT SPECIFY ELECTRICAL REQUIREMENTS FOR z m L5 EQUIPMENT NOT SOLD BY TOSHIBA. THESE REQUIREMENTS MUST BE OBTAINED BY J J cd UNISTRUT NOTESUNISTRUT THE VENDOR. N 9 ALL LED ACCORDING STRUCTURAL SUPPORT DEVICES INSTALLED AND I. CUSTOMER/CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE LIGHTING H. CEILING UNISTRUT SUPPORT STRUCTURES TO BE DESIGNED BY OTHERS BA5ED ON W LEVELED ACCORDING LL D AND SPECIFICATIONS ON SITE PLANS. FOR SERVICING OF EQUIPMENT IN ALL AREAS OF THE INSTALLATION. SPECIFICATIONS SHOWN ON TOSHIBA SITE PLANS (IF APPLICABLE). E. TOSHIBA WILL SUPPLY INTERCONNECTING CABLES FOR THE TOSHIBA EQUIPMENT.10. ROOM LIGHTING INSTALLED AND OPERATIONAL. 0 J. THE CUSTOMER/CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL COSTS I. UNISTRUT OR EQUIVALENT CHANNEL SUPPORT SYSTEM TO BE SUPPLIED AND INSTALLED TOSHIBA WILL INSTALL IF LOCAL TRADE LABOR PERMITS. to ENSURE THAT LIGHTING SPRINKLER HEADS PRESENT NO CONFLICT WITH UNITS REQUIRED FOR THE ENGINEERING AND/OR REMOVAL OF ANY HAZARDOUS MATERIALS BY CUSTOMER CONTRACTOR IF APPLICABLE / ( )• F. EXCEPT FOR THEIR USE IN POWER LINE CONNECTIONS TO EQUIPMENT CABINETS, d 11. MOUNTED TO THE CEILING. SUCH AS ASBESTOS. FLEXIBLE CONDUIT SHALL NOT BE USED IN THIS INSTALLATION. ONLY FACTORY J. UNISTRUT ARE TO BE P1001 OR P5001 OR EQUIVALENT, MOUNTED FLUSH WITH CONDUIT ELBOWS SHALL BE USED. O: 12 ENSURE THAT NON-TOSHIBA SUPPLIED EQUIPMENT PRESENT NO CONFLICT WITH K. CUSTOMER/CONTRACTOR SHALL SUPPLY AND INSTALL MATERIALS AND OTHER FINISHED CEILING. ALL UNISTRUT ARE TO BE MOUNTED..PARALLEL AND LEVEL WITH A UNITS MOUNTED TO THE CEILING. FEATURES SPECIFIED IN THE TOSHIBA SITE PLANS. CUSTOMER/CONTRACTOR SHALL MAXIMUM DEVIATION OF 1/16". UNISTRUT IS TO BE CAPABLE OF SUPPORTING LOAD G. DUCT WORK SHALL BE PROVIDED WITH SWEEP ELBOWS. d 13. 110V ROOM OUTLETS OPERATIONAL. SUPPLY AND INSTALL ALL COUNTERTOPS, SINKS, CASE WORK AND CABINETS REQUIREMENTS OF TOSHIBA EQUIPMENT. UNISTRUT LOAD REQUIREMENTS AND DESIGN ARE r,.l SPECIFIED IN THE TOSHIBA SITE PLANS. THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER OF RECORD. H. ALL JUNCTION BOXES AND DUCTS THAT PENETRATE THE FLOOR SHALL BE o a w Z x ALL CONTRACTOR-SUPPLIED CABLES PULLED AND TERMINATED, INCLUDING WATERPROOF TYPE AND PROVIDED WITH GASKETED WATERPROOF COVERS. ALL FLOOR a o In Q 14. GROUND WIRE AND GROUND BUS BAR IN TROUGHING AS SPECIFIED IN THE LU G K. CUSTOMER/CONTRACTOR TO SUPPLY AND INSTALL UNISTRUT P2751 TROLLEYS OR JUNCTION BOXES AND DUCT COVERS SHALL BE CAPABLE OF SUPPORTING A 2 u N L. PLUMBING IS NOT REQUIRED FOR THIS TOSHIBA EQUIPMENT. EQUIVALENT. CONTACT THE TOSHIBA INSTALLATION PROJECT MANAGER FOR,APPLICABILITY CONCENTRATED LOAD OF 200 LBS. N F TOSHIBA SITE PLANS. AND QUANTITY OF TROLLEYS. UNISTRUT TROLLEYS SHOULD HAVE VINYL WHEELS. w Z INTERFACE FOR DIMMING OF ROOM LIGHTS (IF APPLICABLE), WARNING LIGHTS M. IT IS RECOMMENDED THAT A SINK BE PROVIDED FOR USE BY PERSONNEL. I. GROMMETED OPENINGS ARE SHOWN FOR REFERENCE PURPOSES ONLY. VERIFY SIZE 3 V 15. AND DOOR SWITCHES INSTALLED AND INTERFACE AVAILABLE AND CONNECTED - ACCESS NOTE AND LOCATION WITH TOSHIBA REPRESENTATIVE. ALL GROMMETED OPENINGS SHALL w .7 (RELAYS, ETC.). SITE CONDITIONS L. CUSTOMER/CONTRACTOR TO PROVIDE TWO 24" X 24" CEILING ACCESS PANELS FOR HAVE NO SHARP EDGES. o a N. DIMENSIONS TO WALLS AND OR OTHER ROOM FEATURES, EXCEPT FOR NOTED COLUMN SERVICING OF CEILING MOUNTED EQUIPMENT. A MINIMUM CLEARANCE OF 36"ABOVE < F 16. DUST-FREE ENVIRONMENT IN ALL RELATED ROOMS. AND BEAM CENTER LINES SHALL BE FROM FINISHED SURFACES. FINISHED CEILING IS REQUIRED IN THE AREA OF THE.ACCESS PANELS. J. ALL CHASE & GROMMETED OPENINGS SHALL HAVE PLASTIC/NYLON BUSHINGS. z rn x 17. HEATING AND AIR-CONDITIONING INSTALLED, OPERATIONAL, AND STABILIZED PER 0. IT IS RECOMMENDED THAT CARDIO/VASCULAR EQUIPMENT REMAIN OUTSIDE 1 GAUSS 11-06-14 K. ALL WALL DUCT WORK SHALL HAVE A MINIMUM NUMBER OF COMPARTMENTS �TOSHIBA SITE PLANS. FILTERS TO BE CHANGED 24 HOURS BEFORE DELIVERY. FIELD OF MR EQUIPMENT. < ZSPECIFIED IN THE ELECTRICAL DUCT LEGEND (SHEET E1). TRANSITIONS SUCH AS < O 2 18. ALL MILLWORK COMPLETE AND INSTALLED. SPECIAL NOTES HORIZONTAL TO VERTICAL WALL DUCT OR WALL DUCT TO JUNCTION BOXES MUST BE o 0 TRANSPORT REQUIREMENTS REVIEWED ON AN INDIVIDUAL BASIS WITH THE INSTALLATION PROJECT MANAGER. LOCAL o z SPECIAL SEISMIC CERTIFICATION TO MAY REQUIRE THE USE OF CROSS-OVER TUNNELS OR OTHER SUCH DEVICES ,2 N 19 PLUMBING COMPLETED (INCLUDING GASES, IF APPLICABLE) ACCORDING TO P. EQUIPMENT INGRESS ROUTE MUST BE CHECKED PRIOR TO EQUIPMENT DELIVERY TO A. THE FOLLOWING COMPONENTS HAVE SPECIAL SEISMIC CERTIFICATION: TO MAINTAIN CABLE SEPARATION. 0 ENSURE THE LARGEST AND HEAVIEST ITEMS OF EQUIPMENT CAN BE ACCOMMODATED, a TOSHIBA SPECIFICATIONS ON SITE PLANS. L. ALL DUCT AND CONDUITS SHALL BE ELECTRICALLY BONDED AS A GROUNDING PATH IN F- N I 0 DIMENSIONS OF CORRIDORS SHOULD BE NO LESS THAN 5'-11". A.A. OSP-0.162-10 20. OPTIONAL COMPUTER FLOORING INSTALLED, IF APPLICABLE. PCDU/VRDU (AS APPLICABLE) ACCORDANCE WITH NEC ARTICLE 517-13(8). o o LL Q THIRD PARTY VENDED ITEMS SUCH AS PROCESSORS, M. CUSTOMER/CONTRACTOR SHALL SUPPLY FILMCHANGERS, 0. RECOMMENDED ENTRANCE TO SCAN ROOM SHOULD BE NO LESS THAN 4'-0"W X A.B. OSP-0013-10 . LY AND INSTALL GREENLEE NYLON MEASURING a a LouHEAVIE TELEPHONE LINES (VOICE AND OPTIONAL MODEM) INSTALLED AND OPERATIONAL. LARGEST AND HEAVIEST ITEMS OF EQUIPMENT FOR THIS INSTALLATION. 21. INJECTORS, GAS PEDESTALS, PHYSIOLOGICAL MONITORING EQUIPMENT, ETC., 6'-11"H FOR EQUIPMENT DELIVERY. EATONUNINTERRUPTIBLE POWER SUPPLY-9390 (AS APPLICABLE) N INSTALLED AND OPERATIONAL. A.C. OSP-0088-10 PULL STRING OR EQUIVALENT IN ALL CONDUITS AND CLOSED DUCT WORK.R. CONTACT THE S INSTALLATION PROJECT MANAGER FOR DETAILS OF THE C & C POWER INC. BATTERY CABINET-BC55 (AS APPLICABLE) N. CONDUIT RUNS SHOWN ARE SCHEMATIC ONLY. ALL CONDUIT RUNS MUST TAKE THE n 22. A DEDICATED PHONE LINE IS REQUIRED FOR SITES THAT ARE RECEIVING NETWORKING REQUIREMENTSB. WEIGHTS SHOWN ON THE OSP DOCUMENTS ARE GENERALLY A MAXIMUM AND THE m INNERVISION. SHORTEST MOST DIRECT ROUTE POSSIBLE. N S. NETWORK REQUIREMENTS WILL VARY BY SITE. A REPRESENTATIVE WILL REQUIRE WEIGHTS SHOWN ON THESE SITE PLANS REFLECT THE EQUIPMENT AS ORDERED. 0. CONDUIT RUNS MAY HAVE A MAXIMUM OF (3) 90' BENDS. 23. ALL UNFINISHED AREAS SEALED OFF TO PREVENT DUST CONTAMINATION. DICOM DEVICE INFORMATION, ADDITIONAL I.P. ADDRESSES, AND I.T. DEPARTMENT P. 110VAC GROUNDED OUTLETS SHALL BE PROVIDED ON WALLS NEAR THE TOSHIBA 0 CONTACT INFORMATION PRIOR TO INSTALLATION. 2a RECEPTACLE FOR TRASH AVAILABLE (LARGE ENOUGH FOR SHIPPING CRATES IF 11-06-14 REQUIRED). 11-06-14 EQUIPMENT FOR USE DURING EQUIPMENT SERVICE. LL Cn I- uj Li HVAC REQUIREMENTS Q. CUSTOMER/CONTRACTOR MUST SUPPLY AND INSTALL ALL INCOMING POWER CABLES J LLJ LJ: 25. SUB BASE PLATE(S) INSTALLED (IF REQUIRED). FROM CIRCUIT BREAKER(S) TO TOSHIBA EQUIPMENT CONNECTION POINT. CABLE TYPE J �' IO 26. "PCDU/VRDU/UPS" INSTALLED AND CONNECTED TO "CB". FOR THES TOSHIBA EQUIPMENT TO OPERATE PROPERLY. C CUSTOMER PROVIDE THE NECESSARY HVAC REQUIREMENTS MUST BE MTW. MULTI-STRAND COPPER - NO ALUMINUM IS PERMITTED. CABLE SIZE Q W J 0 rr') z T - 3)T BE IN ACCORDANCE WITH TOSHIBA POWER QUALITY REQUIREMENTS. (SEE SHEET > P LLJ Q D SEISMIC REQUIREMENTS, AND REQUIRED SEISMIC ANCHORING DEVICES INSTALLED SYSTEM OPERATION AMBIENT TEMPERATURE RANGE: 64' - 91' F RE O 27. (IF APPLICABLE). R. CUSTOMER/CONTRACTOR z STOMER/CONTRACTOR IS TO SUPPLY AND INSTALL ALL NECESSARY HARDWARE TO W 28. NETWORK CONNECTIONS INSTALLED AND OPERATIONAL EXAM R X 0 J M ROOM: TEMPERATURE RAT R: 64.- 74' F PER ROOM- ENCLOSE INCOMING POWER CABLES IN FLEXIBLE WATER TIGHT CONDUIT FROM CIRCUIT C9 (, Z BREAKER(S) TO TOSHIBA EQUIPMENT CABINET(S). aC W Q 73 CONTROL ROOM: '.- 74' F G z J W 29. ALL APPLICABLE PERMITS OBTAINED. EQUIPMENT ROOM: - 78' F S. c WITH EQUIPMENT HEAT LOADS ANY CHANGES IN THE LOCATION OR TYPE OF CONDUIT, DUCT WORK, JUNCTION J z S (SEE EQUIPMENT LEGEND SHEET Al)NOTICE: HUMIDITY RANGE OF 35-70% NON-CONDENSING BOXES, ETC. MUST BE SUBMITTED IN WRITING TO THE TOSHIBA INSTALLATION PROJECT J C� / Q I J CUSTOMER MUST COMPLETE ALL ITEMS ON THIS CHECKLIST BEFORE SCHEDULED DELIVERY OT MANAGER FOR APPROVAL. W W FURTHERMORE,THE EQUIPMENT WARRANTY MAY BE VOIDED. ►-� B. AIR SUPPLY DUCTS SHOULD NOT BE PLACED DIRECTLY OVER EXAMINATION TABLES FOR COMMENTS: DATE FOR THE EQUIPMENT.IF CUSTOMER FAILS TO DO SO,DELIVERY MAY BE DELAYED. A. A MINIMUM OF 10 AIR CHANGES PER HOUR IS SUGGESTED, CONSULT LOCAL CODE. A SEPARATE CIRCUIT, FED FROM THE FACILITY RADIOLOGY PANEL OR A MAIN SERVICE Lu W T. PANEL IS REQUIRED. USE OF A SUB PANEL WITH LOADS SUCH AS ELEVATORS, HVAC, m O z it PATIENT COMFORT. MOTORS, ETC. IS NOT PERMITTED. J �'. a L C. EQUIPMENT _O CD SPACES SUCH AS EQUIPMENT ROOMS, TRANSFORMER CLOSETS Lu Lu AND COMPUTER U, ALL DUCT WORK MAKING A 90' ANGLE MUST BE CHAMFERED FOR CABLE ACCESS.ER ROOMS MUST BE PROVIDED WITH ADEQUATE VENTILATION. V. JUNCTION BOX SIZES MAY BE INCREASED AS NEEDED (WITH THE EXCEPTION OF THE y (5 00"" JUNCTION BOX). "" / "VRDU / OR PDU a/ SIGNED TOSHIBA: D. THE AIRFLOW THROUGH TOSHIBA EQUIPMENT CABINETS IS FROM BOTTOM TO TOP. WHERE "PCDU 01-07-15 Z O POSSIBLE, AIR CONDITIONING SUPPLY OUTLETS SHOULD BE LOCATED AT FLOOR LEVEL CONTRACTOR: WITH RETURN GRILLES IN THE CEILING. CUSTOMER: E. A/C SUPPLY OUTLET TO BE PROVIDED BY CUSTOMER AT FLOOR LEVEL AT CONTROL ROOM DESK. F. A THERMOSTAT IS REQUIRED IN EACH ROOM THAT CONTAINS TOSHIBA EQUIPMENT. THESE TOSHIBA PLANS ARE FOR 11-06-14 INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR G. THE EQUIPMENT ROOM(S) THERMOSTAT REQUIRES A VISUAL AND AUDIBLE ALARM WHEN ANAGREEY AGREED UPURPOON BETWEEN TOSHIBA OTHER THAN THAT LSE SPECIFICATION THE TEMPERATURE REACHES 78' F. AND THE CUSTOMER.THESE SITE 11-06-14 PLANS ARE NOT TO BE USED FROMRFRONT CENTER OF UNIT. VIBRATION SPECIFICATION FOR CONSTRUCTION PURPOSES. 65 dB - 3'-3 C-ARM & TABLE DATE: 05-13-15 COOLANT CIRCULATOR ACCELERATION MUST BE 0.397"/S' (1 CM/S') OR LESS, IF FREQUENCY BAND OF VIBRATION 3'-3" FROM FRONT CENTER OF UNIT. IS LESS THAN 10 Hz. SCALE: NOT TO SCALE 57 dB (71 dB DURING ALARM BEEPING) ACCELERATION MUST BE 3.93751-/S2 (10 CM/S') OR LESS, IF A FREQUENCY BAND OF DFP-8000 VIBRATION IS EQUAL TO OR MORE THAN 10 Hz. PLANNER: L.B.C. 63 dB 11-06-14 XTP-8100G CABINETS CEILING HEIGHT SID: 30027352 SOUND PRESSURE LEVEL, NOT ACOUSTIC POWER LEVEL MEASURED 3'-3" FROM FRONT CENTER AND 3'-3" FROM FLOOR 50 dB STANDBY PROJECT NO. [f 53 dB PULSE FLUORO 150015249VLF1 RECOMMENDED-CEILING HEIGHT: 9'-4" MINIMUM CEILING HEIGHT: 8'-10 5/16" 11-06-14 ems. 11-06-14 EQUIPMENT LEGEND ITEM ELEC. ITEM DESCRIPTION BTU/HR WEIGHT REF. A SYM. SUPPLIED AND INSTALLED BY TOSHIBA Ot C880 CAS-880 (5-AXIS POSITIONER - FRONTAL) 342 2,426 t&2 A2 _: O2 CAT CAT-8808 PATIENT TABLE (CRADLE TILT) 1,843 1,389 4 •O O3 MS 58" MONITOR SUSPENSION & BACKUP MONITOR 1,705 425 ra Em 20-2" O4 RSL 4M TRACK WITH RADIATION SHIELD WITH LAMP - 167 e CABS XTP-810OG CABINET SIDE COVER - 89 1 t A3 }m RACK CABINET 2 So O CAS (CAS-880 C-ARM CONTROL CABINET) 1,536 33. Aa •� o ro NOTE: RACK CABINET 2 v EQUIPMENT INNERVISION AND RAID LOCATED ON SHELF. O7 PC (GENERATOR POWER CABINET) 9,350 508 e �I SHELF, BRACKETS, AND ANCHORING SUPPLIED 3 U CLOSET AND INSTALLED BY CUSTOMER/CONTRACTOR. 8 DFP RACK CABINET O 5,119 926(DFP-8000B SYSTEM CABINET) A3 O9 RAID RAID (BTU/HR INCLUDED WITH DFP) - 67 a A3 F U U INNERVISION WORKSTATION a z m m i m i 10 INV (15" MONITOR, KEYBOARD, AND PC) 500 22 A3 y v 22 5 11 WCU HEX-125 WATER COOLING UNIT (WEIGHT WITHOUT WATER) 4,675 67 {V e 10 18 12 11 9 O e � N O 12 CC FPD COOLANT CIRCULATOR (WEIGHT WITHOUT COOLANT) 3,754 98 it ............................ ......... ........ .... .... J o A 1 13 CONS DFP-8000D MAIN CONTROL CONSOLE - 6 A3 w z DFP-8000D DIGITAL FLUOROGRAPHY _ s z o o a -fz , �. -a,.`-; 14 CCB CONSOLE CONTROL INTERFACE BOX 45 a o F O LCD LCD MONITOR WITH STAND _ 26al 10 N A3 0 3 V CL 'f y _w~� NOTE: 16 AWS ANGIO WORKSTATION 51 e a a CAS ROTATION C-ARM 'I 1 (21" MONITOR, MOUSE, KEYBOARD, AND WORSTATION) a3 o O ;D ROTATION :f I MINIMUM CLEARANCE LINE i. b �/ t` 2 ; t RECOMMENDED BY TOSHIBA. 17 MIC MICROPHONE AMPLIFIER - 49 12 z w N Z r 19 : 1�. RGE MONITOR MANAGER & VIDEO EQUIPMENT a N r t "MIC' AMP IS TO BE LOCATED ON SHELF 18 LMM 1,705 261 to z ; w 11 BELOW COUNTER. THE SHELF, BRACKETS, O (WALL MOUNTED) e r, n r - ' I "-L________ ) AND ANCHORING ARE TO BE SUPPLIED AND o CAT-1180B TABLE r I I -_j INSTALLED BY CUSTOMER CONTRACTOR. ITEM ELEC. OPTIONAL ITEM DESCRIPTION- 13 g7yMR NIEIGFR' REF. ROTATION T I / SYM. SUPPLIED&INSTALLED BY TOSHIBA �n �n Q9 r --- F O - - - --- - OTE: 19 INJ MEDRAD MARK VII INJECTOR (TABLE MOUNTED). - 7 o i i Y. Lij 3 SHELF/COUNTER PROVIDED e o 0 BY CUSTOMER/CONTRACTOR. 4 20 INJR MEDRAD MARK VII INJECTOR REMOTE PANEL 5 e Qo a W � .1- 21 INJC MEDRAD MARK VII INJECTOR ELECTRONICS CONSOLE - 43 e " W ' """' ITEM^t ELEC. OPTIONAL ITEM DESCRIPTION-SUPPLIED BY TOSHIBA N M f t BTUIHR WEIGHT REP. W t SYM. &INSTALLED BY CUSTOMER/CONTRACTOR t4^ t 22 PCDU PCDU-100VL POWER CONDITIONING DISTRIBUTION UNIT 2,421 700 A3 W W �- ~ 20 16 ITEM ELEC. OPTIONAL ITEM DESCRIPTION J W O tt 17 SYM. SUPPLIED AND INSTALLED BY CUSTOMER/CONTRACTOR BTWHR WEIGHT REF. J O ' 15 21 -4 'Z 15 13 23 PHY PHYSIOLOGICAL EQUIPMENT (RECOMMENDED AREA SHOWN) - - > P. L�J Q 00 23 7 14 CONTROL Z X O J AREAW � o V Z w O � a z z � W - VERIFY IF PHYSIO EQUIPMENT IS u > >�Z y J J ON DESK OR COUNTER PROVIDED 12� W I L�i LPL_ Z BY CUSTOMER/CONTRACTOR. ENTRY T m W J W m Oz � J Q `{Y F� H O_ O O 00 EQUIPMENT LAYOUT Q O L6 0 1' 2' 4' THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY NOTE: AND SHALL NOT BE USED FOR 24" (600mm) DIAMETER EMBEDDING AREA FOR 5-AXIS C-ARM MUST ANY PURPOSE OTHER THAN THATADREED UPON BETWEEN TOSHIBA BE 2 3 8 (60mm) DEEP FROM FINISHED FLOOR TO MOUNTING AND THE CUSTOMER.THESE SITE SURFACE. 5-AXIS C-ARM MUST NOT BE SURFACE MOUNTED ON FLOOR. PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. FLOOR LEVELNESS/DEVIATION MUST NOT EXCEED DATE: 05-13-15 1/16" RISER OVER 3'-3 3/8" (2mm/1000mm) SCALE: 1/4" _ 1'-O" RUN OVER ENTIRE AREA OF LAB. SITE PLAN APPROVAL PLANNER: L.B.C. IN ORDER TO USE THIS SET OF FINAL SITE PLANS, A CUSTOMER SIGNATURE IS REQUIRED BELOW. THE CUSTOMER'S SIGNATURE DEMONSTRATES ACCEPTANCE OF THE LAYOUT SHOWN SID: 30027352 AND ALL STATED SPECIFICATIONS. CUSTOMER: DATE: PROJECT NO. SALES: DATE: 150015249VLF1 I.P.M.: DATE: ceso HEAT OUTPUT (BTU'S) /w 17'-8" 342 /►,♦ WEIGHT (LBS) / 5'-0" 5'-10 7/8" 3'-7 5/16" 2.426 -'' .0 mo wZ ¢o m0 Q Q¢ `` UH F"H I / CAS-880A C-ARM MOVEMENT ¢ o 0 O 00 o rn CAS-880A FLOOR MOUNTED < - - -—- - 5-AXIS POSITIONER o N /.., ............................. ..... .....j................................:................ PLAN _ I MONITOR SUSPENSION U U 00 W O I O - CAT-8808 "-- i w d CAS-880A PATIENT TABLE I j \_ N o a w & CAT-880B --- - - ---------�- - I of o \ a O U) O U) v ` z V, r ¢ Q Z I \ I = = O o 4 METER TRACK o z V I I W/RADIATION SHIELD w i I r at2 O MINIMUM CLEARZONE RECOMMENDED BY TOSHIBA o o Q ........................ ............. ...�.,�.....�........................�........... .................................. Q Q W\\ I I .................. SIDE T-0 i/4" N m CAT-8806 TABLE ROTATION WHILE FULLY EXTENDED. 2 CAS-880A FLOOR MOUNTED C-ARM O 20'-1 3/4" SCALE: 1/2" = 1'-O" 11-06-14 �" Li- (n J W LLJ N PLAN 14'-1 5/16" J 2i CD CAT Q W J n Z 9-8 1/8" 4'-5 1/8" HEAT OUTPUT (BTU's) > ~ W Q oo MONITOR SUSPENSION 1,843 V {x X 12:� Q J 4'-5 1/8" 5'-3" WEIGHT (LBS) _Z Z low a LL z O 13 3/4" U) Z J J W Q CAS-880A W I LLw LL Z FLOOR MOUNTED I "� J W 5-AXIS POSITION I fO I 7 W ER m O z 19 \ -------------- --- M - --�-- _ —� g ° � W H O N O OC _. --------------' _ M e ^ 00 Z PLAN < O I l"� I �o 5'-8 5/16" THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY "'^••.,--^ m AND SHALL NOT BE USED FOR CAT-880B ..�`•� 1,. ANY PURPOSE OTHER THAN THAT PATIENT TABLE - -----^__=_______��--------------'---^ �I---`� ,,,""^•, "tea AGREED UPON BETWEEN TOSHIBA '1 ..^'"" `"•.^1 ^,++r„' �^rr� AND THE CUSTOMER. THESE SITE PLA BE USED FOR NCONSTRUCTION S ARE NOT OPURPOSES. y io tO DATE: 05-13-15 0 SCALE: AS NOTED ci CAT-880B TABLE ROTATION "I m o ro o PLANNER: L.B.C. aoQ ma c3ir MINIMUM CLEARANCE AT FOOT END SID: 30027352 7-0 1/4 5-10 7/8 TABLE HEIGHT: 2'-7 1/4" (794mm) SIDE TABLE TOP SLIDING: FOOT END MAXIMUM FOOT END PROJECT NO. SIDE LATERIALDINA TI TL RIIGHTHEAD DOWN UP DOWN1500155249VLFI 0 INFINIX ELITE/FM 3 CAT PATIENT TABLE (CRADLE TILT) �_.. SCALE: 1/2" = 1'-0" 11-06-14 SCALE: 1/2" = 1' 0" 11-06-14 CABS CAS DFP RAID INV ^ HEAT OUTPUT (BTU's) HEAT OUTPUT (BTU'S) HEAT OUTPUT (BTU's) HEAT OUTPUT (BTU's) HEAT OUTPUT (BTU'S) �^ 17 13/16" - 1,536 5,119 INCLUDED WITH 'DFP" 500 WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) " WEIGHT (LBS) C 16" 89 22 9/16 f► .j 331 30 7/16 926 67 Y4 /., O PLAN 11 13/� PUN t I HEAT OUTPCT (BTU's) P LAN 1 3 3/8" ±'. 9,350 PLAN O HWEIGHT (LBS) PLAN [......I C pj 2'-3 1/4" m io io n 13 •��! raj n 12 1 1/1 6" v••� n � J FRONT SIDE M ^ U U Z m m J J SIDE FRONT FRONT SIDE FRONT SIDE FRONT SIDE y O DFP-8000B IL 7 CABINET SIDE COVER * RACK CABINET O SYSTEM CABINET RAIDO O I ALE: 1" SION WORKSTATION w LSCALE: i/2" = 1'-0" 01-07-15SCALE: 1/2" = 1'-0" 11-06-14 SCALE: 1/2" = 1'-O" 11-06-14 SCALE: 1/2" = 1'-O" 11-06-14 SCALE: 1" = 1'-0" 11-06-14 Z � w 0 a T. a 0 N O WCY CC co CONS n CCB LCD w F HEAT OUTPG7T (BTU'S) HEAT OUTPUT5 3,754(BTU's) 4 ®� ® HEAT OUTPUT (BTU'S) tO HEAT OUTPUT (STU'S) HEAT OUTPUT (BTU'S) z �. WEIGHT (LBS) WEIGHT (LBS) CDO�O e 008S° WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) a 67 (WITHOUT WATER) 98 6 45 26 z I, N 13 1/8'. 18 11/16" z 17 11/16" 9 13/16" Z5 L> O PUN 0 i V PUN PLAN 11 7/8" in u� w I I 12 3/16" 10 7/8" o N t2 O 0 PLAN PUN 0 o Q 14� 1s� 110 Ulu) 6 9/ts" � � �° //y��• ❑❑� ❑ M M N \ < W N W 0 0 O M Y ^ _ W O Cn r W \ w ~ 00 N j � � � O O FRONT SIDE (i;' FRONT SIDE a W J C) � Z FRONT SIDE FRONT SIDE FRONT SIDE V ' W O 00 iW X � 0 -J HEX-125 WATER COOLING UNIT DFP-8000D DFP-8000D CONSOLE a J z O O O FPD COOLANT CIRCULATOR MAIN CONTROL CONSOLE O O CONTROL INTERFACE BOX 7 Q LCD MONITOR WITH STAND a z J J SCALE: 1" = 1'-O" 11-06-14 SCALE: 1" = 1'-0" 11-06-14 SCALE: 1 1/2" = V-0" 11-06-14 SCALE: 1" = 1'-O" 11-06-14 O SCALE: 1" = 1'-O" 11-06-14 U) V he I -- � W AWS MIC W m O z HEAT OUTPUT (BTU'S) HEAT OUTPUT BTU'S PCDU LMM C@ (BTU'S) HEAT OUTPUT (BTU's) HEAT OUTPUT (BTU's) � G � � > V- WEIGHT LBS . 2,421 1,705 1- — ~ O o 0' (LBS) WEIGHT (LBS) WEIGHT (LBS) WEIGHT (LBS) N E-D 00 18 3/8" 51 49 21 11/i6" 700 261 z O 16 9/16" LL. 8 �16 PLAN 17 1/2" PLAN THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY PLAN AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT 8 3/16" 20 1/2" AGREED UPON WEEN TOSHIBA AND CUSTOM 2'-6" FOR E0 BE USED RE THESE SITE - - 2-0 PLANS ARCONSR CO NSTRUCTION PURPOSES. PLAN 14 7 17 1.6.. DATE: 05-13-15 a I— ®0 j SCALE: AS NOTED n � p B � PLANNER: L.B.C. n O `o N SID: 30027352 FRONT SIDE FRONT SIDE FRONT SIDE PROJECT NO.150015249VLFI FRONT SIDE ANG10 WORKSTATION PCDU-100VL LMM 11 7 2 MICROPHONE AMPLIFIER 3 POWER CONDITIONER 4 LARGE MONITOR MANAGER SCALE: 1" = 1'-0" 11-06-14 SCALE: 1" = 1'-O" 11-06-14 SCALE: 1/2" = 1'-0" 11-06-14 SCALE: 1" = 1'-0" 11-06-14 C (A) C-ARM ROTATION ANGLE LAO/RAO/CRA/CAU = 0% 100 cm ABOVE THE FLOOR (3) C-ARM ROTATION ANGLE LAO/RAO/CRA/CAU = 0% 150 cm ABOVE THE FLOOR (A) C-ARM ROTATION ANGLE LAO = 90', CRA/CAU = 0', 100 cm ABOVE THE FLOOR (B) C-ARM ROTATION ANGLE LAO = 90', CRA/CAU = 0% 150 cm ABOVE THE FLOOR 0 'm O 0.002 0.004 \ \ \ / / / %/ �'•\ \`\ \ \ % / 0.001/ / \ \, \ \ \ / / 0.001/ / \ \ \• \ j I l 0.01s % 1 j I l 1 o.00a \, \ 1 I / %o.00 It I I I o.0os I I j I I 0.01s 1 I I I I I rz m m II 1 \ ,\� 1 \ l I — \,\ / / 1\ \ \ o.00a / / / 1\ 1\ \ / % b.00 1 \ \ \ �' /k1.00 H ,\ \, 0.004 ' \ \ \ \•\•_ ! / / \ \ \0.002 i uj 0.016 0.016 j '\ \.\ '•� \ 0.002 !,/ /' '`\ \ \,\ //� �' �, '�\ \, 0.008 0.008 /: / �' \ `,\ 0.008 0.008 / % C •\__------' 004 0.004� 0 004 %/ \ \`• �. i / / \. 0.001 ./" / \, •\., 0.001 % \•• !' 0.002 - `.0.002`•� '0.002, �. 0.002 \ j i z i, U N _O 50 cm ~� C) rn cn 50 cm 50 cm 50 cm o z o V MICROGRAY PER MICROGRAY SQUARE METER MICROGRAY PER MICROGRAY SQUARE METER MICROGRAY PER MICROGRAY SQUARE METER MICROGRAY PER MICROGRAY SQUARE METER o NGY / (YGY - m') yGY/ (AGY - m') NGY / (yGY • m') PGY/ (AGY - m') I H�j J Z z FRONTAL - 100 cm ABOVE FLOOR FRONTAL - 150 cm ABOVE FLOOR LATERAL - 100 cm ABOVE FLOOR LATERAL - 150 cm ABOVE FLOOR O 0 z u- u� C-ARM CONFIGURATION 7 (FRONTAL POSITION) C-ARM CONFIGURATION o N � 2 (LATERAL POSITION) p -O 1 O " = ' " �i o � {V SCALE: 1/4" = 1'-0" 11-06-14 SCALE: 1/4 11-06-14 a a N N W _ m M O J W -3i E J OC �— O aW o � z > i- w o � >; � z X 0 -10 W z V W Q Z H V z z J v Y � I —i W J � m � z W L6 Lu m _O O m O 0 m Z Q U. THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. DATE: 05-13-15 SCALE: AS NOTED PLANNER: L.B.C. SID: 30027352 PROJECT NO. 150015249VLF1 FLOOR STRUCTURAL LEGEND ITEM ITEM DESCRIPTION ^ SUPPLIED AND INSTALLED BY TOSHIBA REP. ^ ❑A CAT-880B TABLE BASE 1&3 c 1.; ITEM DESCRIPTION OITEM SUPPLIED BY TOSNIBA AND INSTALLED BY CUSTOMER I CONTRACTORANCHOR BRACKET FOR RACK CABINET, VERIFY LOCATION W/TOSHIBA REP. ;O ❑C ANCHOR BRACKET FOR DFP SYSTEM CABINET, VERIFY LOCATION W/TOSHIBA REP. 53 ITEM ITEM DESCRIPTION NOTE: REP SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR e LEVELING EPDXY MAY BE USED TO MEET FLOOR LEVELNESS ❑D BACKING PLATE FOR RACK CABINETS, VERIFY LOCATION W/TOSHIBA REP. s3 �� SPECIFICATIONS. CUSTOMER/CONTRACTOR IS RESPONSIBLE FOR O PROVIDING AND POURING EPDXY TO MEET TOSHIBA'S SPECIFICATIONS. 36"W X 36"H, BACKING PLATE FOR IMM". HEIGHT-TO BE DETERMINED AT TIME OF 1 10'-9, 3'-6" INSTALLATION. s1 1 10'_2" 0L m 5 FLOOR LEVELNESS/DEVIATION MUST NOT EXCEED 1/16" RISER OVER CAS-880A BASE PLATE 7&2 J CORE DRILL a a. 3'-3 3/8" (2mm/1000mm) RUN OVER ENTIRE AREA OF LAB. 53 10'-2 7/8" z °'J 2Q NOTE: r ti 3 ri o m 24" (600mm) DIAMETER EMBEDDING AREA FOR 5-AXIS C-ARM MUST m m m 3'-11" z 0 BE 2 3/8" (60mm) DEEP FROM FINISHED FLOOR TO MOUNTING m y op SURFACE. 5-AXIS C-ARM MUST NOT BE SURFACE MOUNTED ON FLOOR. W C U Z 0 0 NOTE: y U w DIAMETER CORE 11 3/8" 16 0 O o DRILL THRU FLO x 0 OR. m 4. w D - n 5 3/8" of E ro 36" W X 36" H p F .7 BACKING PLATE o L U o a w z CORE DRILL a 0 r O %m --- ------------- - to 0 0 U EQUIPMENT wo o C B B a 00 9'-10 1/4" a I I I z ^ M � w rn w H I I � z Q N GO z w 0 #----- O ^ --------------- U' i ANGIO w n n Q� LAE a M O OUTLINE OF WALL (4) 0.406" DIA HOLE CAS-__- C-ARM _ MOUNTED CABINET a a W ROTATION y .7 F �\ W N m EDGE OF BASE O CL CAT-SBOB TABLE W Cn ~ ROTATION Li A LARGE MONITOR MANAGER � O O BACKING PLATE Q W J p �q z 7D' A X METER CORE SCALE: 1" = 1'-0" 11-06-14 > F LiQ Oo DRILL THRU FLOOR. C� Z O r W � � z t� � Z w O V z J J V -J to w � -i W W m OCONTROL a- AREA J L6 N ~ UJ H _O o 1 O D z O L THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT FLOOR SUPPORT LAYOUT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER.THESE SITE PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. 0 1' 2' 4- DATE: 05-13-15 NOTE•CUSTOMER/CONTRACTOR TO SUPPLY/INSTALL SCALE: 1/4" = 1'-O" ALL ANCHORS PER STRUCTURAL ENGINEER OF RECORD SPECIFICATIONS. PLANNER: L.B.C. SID: 30027352 PROJECT NO. 150015249VLF1 CEILING STRUCTURAL LEGEND ITEM ITEM DESCRIPTION �JS2 SUPPLIED AND INSTALLED BY TOSHIBA LONGITUDINAL RAILS C ❑H CEILING RAILS FOR RADIATION SHIELD sz .O ITEM ITEM DESCRIPTION m m SUPPLIED AND INSTALLED BY CUSTOMER/CONTRACTOR REP' > O ❑I P1001 UNISTRUT OR EQUIVALENT 1 sz C 10-9" FINISHED CEILING TOTTOM BE 3 1/4" DESIGNED, SUPPLIED, .dm OFBUNISTORUTVE B�HANNEEDGE & INSTALLED BY 3'-9" ¢0 CUSTOMER/CONTRACTOR oo 00 G° a Z U J �Z a 0 W m 0) UNISTRUT CHANNEL w n a n MOUNTING BLOCK LONGITUDINAL RAIL m m J J -"--" MONITOR N ANGIO SUSPENSION W EQUIPMENT SECTION A-A BRIDGE N CLOSET O SCALE: 2" = 1'-O" 0 a 14'-0" o 1 H [ALL TO BENSING UPPLIEDDBYRE Z 7 1/16" 3,_3" 7'_p" 0 & USTOMER/CONTRACTOR Z J 0 Q 0 0 _ Q UNISTRUT END OF I _— _ --__ UNISTRUT E 0 V) (REFERENCE POINT) RAIL - - N I, o I c3 z c Z 3 -- CAS-880A 6 IC-ARM BASE z y CAS-880A C-ARM UI TIO - LAMP 0A -�l _ Ni ZO < N / O O 2 V --- — — ----- 10 -� n F4-M--1 A Afr 7 7 O CAT:880B TABLE - T RACK � a N ROTATIO - - 7-- --- _--- o LL o p 1.-.I o LONGITUDINAL a co) --- - RAILS _ _— -_—_— —_—_- UNISTRUT G \ CONSULT INSTALLATION LL- V) 24" W W PROJECT MANAGER IF .J W N INSTALLING SYSTEM IN Q M A SEISMIC ZONE. 4'-0" (INSIDE EDGE OF RAILS) .4 W p r� Z CONTROL� o > I. W aDo >- V W X g .J OMONITOR SUSPENSION STRUCTURAL DETAIL a v W ZO SCALE: 1/4" = 1'—O'" 11-06-14 y V z z. J V J 13'-1 1/2" W Q I J LQL_ W x W m O z fLI CEILING SUPPORT LAYOUT 26" O.C. TYP. 13 3/4" J g � O W N O � 0 ,' 2' 4' B' DO 16' .� . . O --- W THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA i"�------ AND THE CUSTOMER.THESE SITE PLANS ARE NOT TO.BE USED / 1 FOR CONSTRUCTION PURPOSES. f� R 30" R 67" DATE: 05-13-15 I / I i NOTE'� � MOVEMENT SHOWN AT1/4" = 1'-0" R 37* �` ; T SCALE: 3/8" = 1'-0" SCALE: NOTE: PLANNER: L.B.C. MAXIMUM EXTENT OF SUPPORT ARM MOVEMENT SID: 30027352 LAMP AND SHIELD SHOWN FOR PROJECT NO. -----^ REFERENCE ONLY. ACTUAL LAMP 150015249VLF1 AND SHIELD MAY VARY. ORAD SHIELD AND LAMP WITH 4 M TRACK �-S2 SCALE: 1/2" = 1' O" 11-06-14 Ej APPROX. 4'-5" NOTE: / APPROX. 24" CUSTOMER'S CONTRACTOR IS RESPONSIBLE FOR FLOOR AREA AROUND 7AS 5'-10 7 8" BASE PLATE TO BE LEVEL WITHIN 1/16" RISE OVER 3'-4" RUN. 08" HOLE THROUGH m z MAXIMUM TOTAL DEVIATION IN LEVEL AT BASE AREA IS 1 16". PLATE AT CENTER OF G 0 13 3/4" DIAMETER / CAS-880A ROTATION a- 2-7 1/2 7" CORE DRILL THRU (CABLE ENTRANCE) 0 p (8) 11/1C HOLES FLOOR IF APPLICABLE PIVOT ARM IS 3/8" ABOVE 1{ \ ` i� } (45' DIVIDED EQUALLY) FNISHED FLOOR AROUND ; \ �r\ - I-` •� 20 7/8 �214" RADIUS OF C-ARM. -' PIT MUST BE FILLED BY 4w \ I CONTRACTOR TO OBTAIN \ � �`.�'' ~1 THE FINAL 24" DIAMETER �^- - ►� w I PIVOT ARM IS 13/16" ABOVE I�..L "`"I EMBEDMENT AREA FOR _ W °' 0 FINISHED FLOOR AROUND 1 �---- ..,;�4ww I CAS-880A. G 0 �4'-5" RADIUS OF C-ARM. 1l -„�,. f 3'-4" p z S. 1 `° 'O W c'� ---------------- -'= ___---- \ MAXIMUM TOTAL o v I I ro , MAXIMUM LEVELNESS 0 C-ARM __ * _ \ <" �a ROTATION a TABLE �, .• .;•'. .�� I .;,, DEVIATION OVER BASE AREA (N.T.S.) LEVEL DEVIATION (N.T.S.) cn � ROTATION � .•a..,+ •.>,•'• ..ti. '•� I Q ' O •�= N Z M N O a I a (6) 013/16" HOLES FOR (2) ADDITIONAL SUPPORT BEAMS REQUIRED FOR C-ARM. , i BASE COVER V/ MOUNTING CAT NEW BEAMS ARE TO BE PARALLEL TO EACH OTHER AND 7 5/16" BASE TO FLOOR. PERPENDICULAR TO EXISTING BEAMS. SPECIFICATIONS TO I CUSTOMER PROVIDED 4 TABLE BASE J BE DETERMINED PERSTRUCTURALN WEER OF R ORD NO SHARP EDGES24" J-BOX (TYP.) FLOOR PLATE (DESIGNED AROUND 08 HOLE PER STRUCTURAL ENGINEER BY ENGINEER OF OX OF RECORD 12 3/16" 12 3/16" J-B UNDER BASE PLATE. SEE ELECTRICAL LAYOUT FOR SIZE. CONCRETE z m of J � �� 7" CORE DRILL BASE PLATE TO BE DESIGNED AND VERIFIED PER FLOOR LEVELNESS/DEVIATION MUST NOT EXCEED 1/16" RISE OVER 3'-4" RUN (ENTIRE AREA OF LAB). AREA WITHIN yJ-BOX W STRUCTURAL ENGINEER OF RECORD. BASE PLATE 4'-3 3/16" DIAMETER AT 5-AXIS C-ARM ROTATION MUST BE EXAMINED &VERIFIED BY TOSHIBA REPRESENTATIVE. w TO BE PROVIDED BY CUSTOMER/CONTRACTOR. 0 IL CONSULT INSTALLATION PROJECT ALL MOUNTING HARDWARE CAS-880A UPPER FLOOR INSTALLATION CAT-880B TABLE INSTALLATION MANAGER IF INSTALLING SYSTEM IS TO BE SUPPLIED O NOTE: Q E E ZA (PROFILE OF PIVOT ARM CLEARANCE TO FLOOR) 3 (SURFACE MOUNTED ON FLOOR W/CORE DRILL) o IN A SEISMIC ZONE. CUSTOMER/CONTRACTOR. NO PORTION OF 1 9 16" m � _ w d THE ANCHOR BOLT / \B \E SCALE: 3 4' = 1'-0" OR THRU BOLT (40mm) m N / 11-06-14 SCALE: 1/2" = 1'-0" Z J LLL / 11-06-14 Z MAY PROTRUDE o m N O MORE THAN THE TOP OF THE BASE FLOOR IS BETWEEN C-ARM BASE D. o N BOLT PROTRUSION FROM EMBEDDING c�i i� PLATE (7/8" FROM ""'� AND CUSTOMER SUPPLIED BASE AREA SURFACE MUST BE WITHIN w z FINISHED FLOOR). I I�. PLATE. EMBEDDING DEPTH: 2 3/8". RANGE OF 2 3 8 0 z o - / - 3 9/16 30 7/16" 22 9/16" 3 �'-- EMBEDDING AREA: 24" DIAMETER. 024" FACE OF WALL FACE OF WALL qa W EMBEDMENT AREA o V I i CAS-880A C-ARM BASE CAT-880B ANCHOR BOLT SECTION OF BASE PLAT PLATE SIZE AND CONNECTION TO ¢ H 1 RECESSED IN FLOOR SCALE: 6" = 1'-0" EXISTING STRUCTURAL MEMBERS TO BE - - -----� --------------1 w DESIGNED BY CUSTOMER'S STRUCTURAL o o i i Z ------------------ --------------------- -------------- ------� ENGINEER OF RECORD. PLATE TO BE `0----------ram I i m ro' a PROVIDED BY CUSTOMER/CONTRACTOR. ` \� \ i I \\\\ ti,, ------------- I I i w o `��` L• ; - N I N O I N O Z r, 1----------- (2) 013/16" THRU (2) 013/16"THRU „r M1• �•"�• ?' ------ LLI 5 3/8" 19 11/16" 5 3/8" 11 13/16" URFACE 24" J-BOX CAT-880B TABLE BASE S W (TYP.) 024" MOUNTED ON FLOOR. _N m L 2 X 2 X 1/4" (2) ADDITIONAL SUPPORT BEAMS REQUIRED FOR C-ARM. "DFP- CABINET SINGLE CABINET � 0 USE (8) 5/8" BOLTS THRU FLOOR OR OTHER SUPPORTING MEMBER NEW BEAMS ARE TO BE PARALLEL TO EACH OTHER AND (DESIGNED BY ENGINEER OF RECORD) (DESIGNED BY ENGINEER OF RECORD) BERDETERMINED pOREXTSUC REAMS^SNECRIOFTIRNSORD W W FLOOR BRACKET FLOOR BRACKET CUSTOMER PROVIDED FLOOR PLATE USE (6) 18 mm BOLTS THRU FLOOR . EXISTING FLOOR DECK SUPPORT BEAMS. SPECIFICATIONS TO NOTE: J f= O 0 (DESIGNED BY ENGINEER OF RECORD) (PER ENGINEER OF RECORD) a W J Z B DET RMIN D PPP TR TURA N IN FR OF R ORD 1. FLOOR AREA AROUND BASE PLATES TO BE LEVEL WITHIN A 1/16" RISE OVER 3'-4" RUN. STRUCTURAL BEAMS THE FLOOR MUST USE CONCRETE WITH A LOAD STRENGTH 2. CONTACT YOUR TOSHIBA INSTALLATION PROJECT MANAGER FOR STRUCTURAL CALCULATIONS > I-' W Q Do '; (DESIGNED BY ENGINEER OF RECORD) OF AT LEAST 2,560 PSI OVER THE ENTIRE FLOOR SURFACE. WHEN INSTALLING IN SEISMIC AREAS. Z 0 V z Z 7 TYPICAL UPPER FLOOR CAS-880A UPPER FLOOR INSTALLATION w 0 MOUNTING OF CAS-880A AND CAT-880B ZB (5-AXIS C-ARM EMBEDDING SECTION) O CABINET FLOOR BRACKETS a z z J w SCALE: 1/2" = 1'-0° 11-06-14 SCALE: 3/4" = 1'-0" 11-06-14 SCALE: 3/4" = 1'-O" 11-06-14 0 0 Z Q COOLING UNIT NOTES 0 - w CUSTOMER I CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING UNLESS OTHERWISE NOTED. Lu m J o 12 Lu QQ o Z W A. THE WATER COOLING UNIT(S) AND COOLANT CIRCULATOR(S) ARE SELF CONTAINED UNITS J �j {L LENGTH VARIES BY SYSTEM TO BE FILLED AND MAINTAINED BY TOSHIBA. PLUMBING IS NOT REQUIRED. _ F-SEE SHEET "S1" B. VENTILATION CLEARANCES AROUND WATER COOLING UNIT 0 OS) AND COOLANT CIRCULATOR(S) o MUST BE MAINTAINED. C. COOLANT CIRCULATOR(S) MUST NOT BE STACKED. Q 0 r------------�--------- ---------� `i U. STEEL PLATE D. HOSES TO THE WATER COOLING UNITS AND COOLANT CIRCULATORS CANNOT BE RUN IN (PER STRUCTURAL ' I I AREAS WHERE THE TEMPERATURES DROPS BELOW 40'F. IF CONDUITS RUN BENEATH ENGINEER OF RECORD) - ___ _______ BACKING PLATE SLAB OR EARTH, ENSURE GROUND TEMPERATURE DOES NOT DROP BELOW 40-F. THESE TOSHIBA PUNS ARE FOR INFORMATIONAL PURPOSES ONLY I I I I E. DUE TO HEAT GENERATED BY THE WATER COOLING UNIT(S) AND COOLING CIRCULATOR(S) AND SHALL NOT BE USED FOR ADDITIONAL VENTILATION RETURN/FAN(S) SHOULD BE LOCATED IN THE VICINITY. ANY PURPOSE OTHER THAN THAT 1 I I AGREED UPON BETWEEN TOSHIBA I I I AND THECUSTOMER. THESE SITE I I I PLANS ARE NOT TO BE USED ' AIR FLOW AIR FLOW FOR CONSTRUCTION PURPOSES. I I I I pj V ,r N DATE: 05-13-15 iG LI SCALE: AS NOTED AIR FLOWS FAIR FLOW AIR FLOWa FAIR FLOW PLANNER: L.B.C. FINISHED FLOOR I I I AIR I SID: 30027352 FLOW I „ ���--- 444 PROJECT NO. -WCU"PLAN VIEW -CC"PLAN VIEW 150015249VLF1 5 WATER COOLING UNIT AND CABINET BACKING PLATE O COOLANT CIRCULATOR CLEARANCE 1' SCALE: 1/2" = -O" 11-06-14 SCALE: 1/2" = 1'-0" 11-06-14 ELECTRICAL LEGEND ITEM REM DESCRIPTION REP. MAIN CB EPO BS SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR MAIN MAIN SERVICE ENTRANCE PANEL E3 CB THREE PHASE CIRCUIT BREAKER PER TOSHIBA POWER SPECIFICATIONS (SEE DETAIL) CIRCUIT 1&s �0 TO BE LOCATED BY CUSTOMER / CONTRACTOR. BREAKER LOCATION PER CODE REQUIREMENTS BY ELECTRICAL CONTRACTOR. E3 - ADDITIONAL "EPO" SWITCHES TO BE LOCATED IN ADJACENT ROOMS WITH CD 18" W X 12" H X 6" D J-BOX, SURFACE MOUNTED 29 1/2" A.F.F. TO BOTTOM OF BOX. e TOSHIBA EQUIPMENT IF MAIN "EPO" IS NOT ACCESSIBLE (VERIFY WITH.LOCAL OPEN TO "VR". SEE TOSHIBA'S POWER QUALITY REQUIREMENTS FOR THE GENERATOR. E3 CODE). ALL "EPO" SWITCHES TO BE PROVIDED BY CUSTOMER / CONTRACTOR. FPO 4" STD. J-BOX FOR REMOTE OFF SWITCH. LOCATED BY CUSTOMER/CONTRACTOR. ei DPDT, NORMALLY OPEN MUSHROOM HEAD PUSH BUTTON. E3 c OT J-BOX SIZES MAY BE INCREASED AS NEEDED WL 4" STD. J-BOX FOR "X-RAY ON" OR WARNING LIGHT MOUNTED ABOVE PATIENT ENTRY e WITH EXCEPTION TO THE "PCDU" J-BOX. DOOR. E3 - 10'-9" NOTE: mo BS BUILDING STEEL. E3 O GROMMETED OPENINGS ARE SHOWN FOR m 10'-8°REFERENCE ONLY. VERIFY SIZE AND LOCATION 3'-6" 24" W X 24" L X 18" D J-BOX, MOUNTED UNDER FLOOR WITH 8" CORE DRILL THRU 7-z WITH TOSHIBA REPRESENTATIVE. to �I C 880 FLOOR. J-BOX TO HAVE REMOVABLE ACCESS COVER. s3 to OT 17" XTP 12" PASS THROUGH WALL DUCT REQUIRED. e J ILL a CAT 10" W X 10" L X 6" D J-BOX, MOUNTED UNDER FLOOR WITH 7" CORE DRILL THRU FLOOR. 53STOMER HAS THE OPTION TO FURR OUT XTP oLL TO ACCOMMODATE FLUSH MOUNTED 4 DUCT IF DESIRED. D2 JBICAB MS 10" W X 10" L X 6" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. J64 WCU CC E3 F o o z m m CCB J J SHARED 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD3". E3 y L- -1- -1-- oN W [�JB5 0 0 i 0 LMM WD1 AWS 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD3". E3 DFP PC CARAID INV SHARED 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WDi". a ANGIO CLOSET CC - Z o a LAB a o = O d U RAID 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD1". 3 o F E3 o ¢ ,+ C88 -=- -=� 3 V t o INV LOCATED ON SHELF. � o - i J CAS-SSOA C-ARM i ' XTP GROMMETED OPENING AT END OF WALL DUCT, "WD1" AND "WD2". OPEN TO XTP-810OG Oz w —i- �— GENERATOR CABINETS. ROTATION N N Q N Z n - -- w INJ CONNECTS TO "PHY2". z Q M O O O am I CAT INJC . o 19 MS SHARED 8" W X 3" H GROMMETED OPENING IN "WD3". 3 w CAT-880B TABLE C 'I INJR E3 a N n G LL ROTATION �- _J HY TRS 11" W X 8" L X 5" D, STEP-DOWN TRANSFORMER, TO BE LOCATED ON SHELF o0 0 Lu INJ (BY CUSTOMER/CONTRACTOR) ABOVE "PCDU"AS LONG AS LOCAL CODE ALLOWS. W N MIC 8" W X 3" H GROMMETED OPENING IN WALL DUCT "WD3". 3 W -0" WD3 E3 RSL LMM 8" W X 3" H GROMMETED OPENING IN WALL DUCT 'WD1". E3 INJR 6" W X 6" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL. FOR CUSTOMER SUPPLIED ` I\- PHY1 PHYSIC, EQUIPMENT IN CONTROL ROOM. VERIFY CONNECTIONS/POWER W/MANUFACTURER. r \ w W � F~- �` HY 18" W X 6" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED FLOOR. FOR CUSTOMER J L.LI 3 O JB6 SUPPLIED PHYSIC, EQUIPMENT AT TABLE. VERIFY CONNECTIONS/POWER W/MANUFACTURER. J Ig Io C INJC HY CUSTOMER SUPPLIED PHYSIC, MONITOR ON MONITOR SUSPENSION. QI W J � Z CCB PHY MIC AWS VERIFY CONNECTIONS/POWER W/MANUFACTURER. > I_ W O D COAREA L JB1 16" W X 16" L X 8" D J-BOX, FLUSH MOUNTED IN FINISHED CEILING. CONNECTED TO � V W X � 0 Z ON "CABS" XTP-810OG END CABINET VIA 6" CONDUIT OR FLEX HOSE. E3 a V z JB2 16" W X 16" L X 6" D J-BOX, MOUNTED UNDER FLOOR WITH 6" CORE DRILL THRU FLOOR. Ea J z z J W .4 12" W X 12" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED s J J V Z >>" JB3 29 1/2" A.F.F. TO BOTTOM OF BOX. OPEN TO "PCDU". E3 W w I W m 10" W X 10" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 24" A.F.F. '� W O Z uj WL 5 J64 TO BOTTOM OF BOX. J @ Q 2�p 2-0 3' JB5 B" W X 8" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 24"A.F.F. TO c J LL. BOTTOM OF BOX. FOR CUSTOMER SUPPLIED VIDEO SIGNALS TO 58" MONITOR. F O Ouj JB6 16" W X 16" H X 4" D J-BOX, FLUSH MOUNTED IN FINISHED WALL, MOUNTED 9" A.F.F. TO 3 coBOTTOM OF BOX. OPEN TO "WD3". E3 z Q: ELECTRICAL LAYOUT 110V ELECTRICAL OUTLETS FOR SYSTEM EQUIPMENT AND/OR SERVICE EQUIPMENT. OUTLETS Q C TO BE LOCATED IN EACH ROOM WHERE SYSTEM EQUIPMENT IS LOCATED. U. 0 2 4 q 16' RJ45 CONNECTOR, CAT5 CABLE TO BE USED FOR DATA CONNECTION FOR NETWORKING. THESE T PLANS ARE FOR . - INFORMATIONAL PURPOSES ONLY DEDICATED PHONE LINE SUPPLIED/INSTALLED BY CUSTOMER/CONTRACTOR. AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER.THESE SITE PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. DATE: 05-13-15 ELECTRICAL DUCT LEGEND SCALE: 1/4" = 1'-0" JI0 ¢I¢ ITEM ITEM DESCRIPTION CAT-880B TABLE ~IC, PHYSIC, BOX SUPPLIED AND INSTALLED BY CUSTOMER I CONTRACTOR REF. PLANNER: L.B.C. � 18" W X 3 1/2° D FLUSH/SURFACE MOUNTED WALL DUCT, W/(3) EQUALLY PARTITIONED 3 WD1 COMPARTMENTS THROUGHOUT & REMOVABLE ACCESS COVERS. MOUNTED 12" A.F.F. TO E3 SID: 30027352 NO EQUIPMENT TO BE ~�`-..� BOTTOM OF DUCT. LOCATED ON HEAD-END SIDE t1" 10" W X 3 1/2" D FLUSH/SURFACE MOUNTED WALL DUCT, W/(3) EQUALLY PARTITIONED 3 PROJECT N0. ~ WD2 COMPARTMENTS THROUGHOUT & REMOVABLE ACCESS COVERS. MOUNTED 12" A.F.F. TO BOTTOM OF DUCT. E3 150015249VLF1 2-5 I _ 9� XTP-810OG GENERATOR SYSTEM COMPONENTS SUPPLIED AND INSTALLED BY TOSHIBA 10" W X 3 1/2" D FLUSH/SURFACE MOUNTED WALL DUCT, W/(3) EQUALLY PARTITIONED NOTE, I� WD3 COMPARTMENTS THROUGHOUT & REMOVABLE ACCESS COVERS. MOUNTED 12" A.F.F. TO RECOMMENDED LOCATION FOR CUSTOMER SUPPLIED PHYSIO BOX AT FOOT END OF TABLE. ECAS SIDE COVER CABINET PCF CAS-880A POWER CABINET BOTTOM OF DUCT. E3 VERIFY LOCATION W/TOSHIBA REP. VERIFY CONNECTIONS/POWER W/MANUFACTURER. VR 10" W X 3 1/2" D SURFACE MOUNTED RISER DUCT, W/(3) EQUALLY PARTITIONED a ELI----' CAS-880A CONTROL CABINET DFP DFP-8000B SYSTEM CABINET COMPARTMENTS THROUGHOUT & REMOVABLE ACCESS COVERS. FROM "PCDU"TO "WD2 E3 xrP xTP CEILING CONDUIT SCHEDULE EPO WD2 CAB JB4 WCU CC CONTRACTOR CONDUIT REFERENCE CABLE REFERENCE MAIN BS Tw "" I I I 1 - RUN CONDUIT CONDUIT CONDUIT CABLE CABLE LENGTH CABLES r ` NO. (POINT TO POINT) (DIAMETER) (MAX LENGTH) (POINT TO POINT) (USABLE) (SUPPLIED BY) go c JB3 LMM WD,J65 01 JB3 RSL PER CODE PER CODE CD RSL PER CODE CONTRACTOR •O Iljl m ' CD m SEE RUN "F" w CB CD ( DFP PC CAS I'i RAID O2 MS JB1 (3) 2" 68'-0" MS DFP DETAIL (1/E4) TOSHIBA O NO TES,TES: VR SEE RUN "0"aI� INV EQUIPMENT O3 MS JB6 2" 85'-0" MS MIC TOSHIBA TRS FOR ABOVE CONNECTIONS, SEE DETAIL 1, SHEET E3. OSET O O O DETAIL (1/E4) ADDITIONAL "EPO" SWITCHES TO BE LOCATED IN ADJACENT ' '.I, O4 JB6 JB1 2 1/2" 60'-01, CCB CAS SEE RUN "J" TOSHIBA ROOMS WITH TOSHIBA EQUIPMENT IF MAIN "EPO" IS NOT II`I DETAIL (1/E4) ACCESSIBLE (VERIFY WITH LOCAL CODE). ALL "EPO" SWITCHES 1 tFt( co SEE RUN "K" TO BE PROVIDED BY CUSTOMER/CONTRACTOR. A GIO ° O JB6 JB1 (3) 2 1/2" 60'-0" CCB DFP TOSHIBA ® •� II°I ALL CABLES AND CONDUITS REQUIRED ARE TO BE PROVIDED � AB DETAIL (1/E4) � BY CUSTOMER/CONTRACTOR. �' PHY1 J61 PER PER pHY1 DFP PER CONTRACTOR MANUFACTURER MANUFACTURER O O MANUFACTURER —" 7 PHY1 MS PER PER PHY1 HY PER J I r 6 2 O O O MANUFACTURER MANUFACTURER O MANUFACTURER CONTRACTOR I � PER PER PER MANUFACTURER I MANUFACTURER WL DFP MANUFACTURER CONTRACTOR I- ci ti II MS I 5 z ao of NOTE' y A. CONDUITS SUPPLIEDANSTALLED BY CUSTOMER/CONTRACTOR. W B. ALL CONDUIT RUNS MUST TAKE THE SHORTEST MOST DIRECT ROUTE POSSIBLE. N ° C. CONDUIT IS NOT TO BE RUN IN SUCH A MANNER THAT WILL EXCEED CONDUIT MAXIMUM LENGTH I II 3 I AS SHOWN IN THE SCHEDULES. O a CONSULT WITH TOSHIBA INSTALLATION PROJECT MANAGER IF CONDUIT WILL BE REQUIRED TO BE �I I RUN IN SUCH A MANNER THAT WILL EXCEED MAXIMUM CONDUIT LENGTH SHOWN ABOVE. a/ I I WD3 E. CONDUITS SHOWN FOR"PHYSIO"ARE OPTIONAL AND MAY NOT BE REQUIRED FOR ALL SITES. I e VERIFY WITH TOSHIBA INSTALLATION PROJECT MANAGER. p RSL a 'I I F. CONDUITS BETWEEN C-ARMS AND COOLING UNITS(CONDUITS 10&11)CANNOT BE RUN IN AREAS z0 d WHERE THE TEMPERATURE DROPS BELOW 40'F.IF CONDUITS ARE RUN BENEATH SLAB OR IN z U 8 INJR ° EARTH,ENSURE GROUND TEMPERATURE DOES NOT DROP BELOW 40°F. O a w G. CONDUITS MARKED WITH AN""'REQUIRE EXTENDED CABLES(SEE DETAIL 1,SHEET E4). a o F O I U N FINAL LENGTH OF CONDUIT TO BE DETERMINED IN FIELD BY LP.M. fUn � � �•. CEILING ELECTRICAL SCHEMATIC Q INJC JB6 Q o V FLOOR CONDUIT SCHEDULE (PROVIDED FOR REFERENCE PURPOSES ONLY) PHY MIC AWS F 0 TROL CCB CONTRACTOR CONDUIT REFERENCE CABLE REFERENCE Z w y AREA ON RUN CONDUIT CONDUIT CONDUIT CABLE CABLE LENGTH CABLES z �' 0 1' 2' 4' 8' 18' Z NO. (POINT TO POINT) (DIAMETER) (MAX LENGTH) (POINT TO POINT) (USABLE) (SUPPLIED BY) 5 O SEE RUN "A" 0 m C880 PO DETAIL (1/E4) TOSHIBA 2 aI (2) 4" SEE RUN "B" ! 4 0 WL O9 C880 J62 COMBINED 45'-0" a C880 CAS DETAIL (1/E4) TOSHIBA o i L6 SEE RUN "C" o o Q C880 DFP DETAIL (1/E4) TOSHIBA Qo a W uj 2 1/2" 65'-0" C88 WCU DETAIL(N "D" TOSHIBA Jet W WD2 CAB JB4 WCU CC 11 C880 JB4 2/ 2 1 ' 65'-O" O O SEE RUN "E" i C88 CC DETAIL (1/E4) TOSHIBA N O 1 Tr- 2" 48'-0" INJ INJR PER CONTRACTOR LL_ _�- O O O O O MANUFACTURER W W SEE RUN "G' j W j LMM JB5 WDi 13 CAT JB6 2" 48'-0" CAT CCB DETAIL (1/E4) TOSHIBA J � � O0 C ' ° SEERUN "G" a W —jE) � Z DFP PC CAS RAID 2 1/2" 48'-0" CAT CCBTOSHIBA W Q 00DETAIL (1/E4) •, I"' ';� INV 11152" & 2 1/2" 50'-0" CAT DFP SEE RUN "H" TOSHIBA VW XLOSEf DETAIL (1/E4) ul !+ z - Z --�� SEE RUN "P' 49 ,•/ LL- W C 16 CAT JB2 2 1/2" 48'-0" CAT CAS TOSHIBA J z (n --- DETAIL (1/E4) Z J —i W /w J V 9 ANGIO I 17 PHY1 HY PER PER pHY1 HY P CONTRACTOR v/ Q C88 - LAB MANUFACTURER MANUFACTURER MANUFACTURER W Q W z LL W 15 � W -i C�• m Oz 19 --__----__-------__--_� G Q 16 {LO ~ O O ~ w ti 00 CAT Q C L----- 13 14 Ld. NJ THESE TOSHIBA PLANS ARE FOR WN -- INJ ' INFORMATIONAL PURPOSES ONLY ' AND SHALL NOT BE USED FOR 12 ( ANY PURPOSE OTHER THAN THAT FLOOR ELECTRICAL SCHEMATIC �� AGRAND U CUSTOMER. BETWEEN THESE SITE 17 WD3 ''.. PLANS ARE NOT ET BE USED (PROVIDED FOR REFERENCE PURPOSES ONLY) FOR CONSTRUCTION PURPOSES. INJR DATE: 05-13-15 0 1' 2' 4' 8' 16' SCALE: 1/4" = 1'-0" CABLE KEY JB6 PLANNER: L.B.C. ®-- OVER CEILING INJC -- IN/UNDER FLOOR PHY CCB MC AWS CONTRACTOR DETERMINED CONTROL SID: 30027352 AREA ON PROJECT NO. LLJ 150015249VLF1 WL NOTE' POWER QUALITY REQUIREMENTS ALL CABLES CONNECTING FROM THE CONTRACTOR IIRECOMMENDED THAT CONTRACTOR PROVIDED INSIDE EQUIPMENT ROOM •----- PROVIDED BY TOSHIBA -----� SUPPLIED RELAY CIRCUITS TO THE SYSTEM TRANSFORMER RELAYS BE LOCATED IN CEILING ABOVE TOSHIBA INFINIX WITH PCDU-100VL (IF POSSIBLE) CABINET ARE TO BE SUPPLIED BY THE CONTRACTOR. XTP-8100G SYSTEM TRANSFORMER CABINET. I � � SUPPLY CONFIGURATION: DELTA OR WYE "MTW" OR WELDING ' TYPE CABLE DFP-8000 SYSTEM KVA RATING: 150.00 O 14 SYSTEM I CONTROLLER CABINET ; �----------------------- -OVD E D BY CONTRACTOR ------------------------- VOLTAGE •� (SEE NOTE B): 48OV, 6OHz MAIN SERVICE SHUNT TRIP PCDU CNN PANEL TB CALCULATED CURRENT (AMP): 180.42 fC ENTRANCE PANEL CIRCUIT BREAKER 12V 5 5 i ' POWER SUPPLY (AMP) SEE NOTE F: 100 O CIRCUIT BREAKER ) ( ) i ' 12V OR 24V i % IMPEDANCE: 5.00 r� ' AC IN POWER LINE RESIST. SPEC.: 0.000 3 POLE 80 AMP DFP --- --- ; ............: SOURCE MAXIMUM CURRENT'(AM PS): 180.42 OV 6 6 OV 1 POLE 15 VOLTAGE DROP(VOLTS): 24.00 48OV, 3 POLE I �� LINE RESIST. (OHMS): 0.133 ROOM LIGHT O •_ 2 POLE 15 AMP --- --- AUX K2 JP 10 10 R CONTROL LINE DROP (VOLTS): 7.20 ' , V 480V, 100 AMP 2- y RY ROOM i CONDUCTOR (OHMS): 0.040 � G I G G 2 POLE 15 AMP --- --- AUX LIGHT TEMPERATURE: 68-F (20-C) INNJ I � 11 11 � CONDUCTOR SIZES NEC 75 'C LENGTH (FT.) 1 POLE 15 AMP --- --- AUX (SEE NOTE E) 01000 Fr. DER TED -3 AWG 0.2540 0.2089 100 96 r 3 6 1 POLE 15 AMP --- --- AUX 12 12 Ry R ' z m m GROUND SOURCE Y L 2 AWG 0.2010 0.1653 130 15 - y PER ' SURGICAL i J J NEC SECTION 250 OPTIONAL 1 AWG 0.1600 0.1316130 152 W 1 POLE 15 AMP --- --- INJECTOR LIGHT SURGICAL 1/0 AWG 0.1270 0.1044 150 191 13 13LIGHT :2/0 AWG 0.1010 0.0831 175 240 0 WIRES PER CODE TO 1 POLE 30 AMP --- DFP Doc- JEMERGEN�Y SHUNT TRIP PUSH BUTTON. PCDU MAX INPUT LUG SIZE 2/0 AWG K1- AUX ; 8 8 POWER OFF Y Ry EPO" X-RAY ON RAY ON IL X- USH BUTTON 2 POLE 50 AMP --- --- DIGITAL 1 ( LIGHT LIGHT z J T. 9 9 o a O SHUNT TRIP PUSH BUTTON IN 2 POLE 70 AMP --- --- DIGITAL 2 i i U v_� ' U 2 CONTROL AREA W/ A NORMALLY , w OPEN CONTACT (IF REQUIRED). rn z • 1 POLE 15 AMP --- --- RECEPTACLE Ry *Ry L 3 O ADDITIONAL "EPO" SWITCHES TO BE LOCATED BY CUSTOMER/CONTRACTOR NEUTRAL-GROUND BONDING, - i i SYSTEM ON qa ' J �IF NEEDED. CHASSIS BONDING, LIGHT y& GROUND ELECTRODE -----------------------------------' •.......----------............. ----......• J z Z i CONNECTION ARE FACTORY a = Z � O CONNECTED. - � � CONNECTING THE RELAY TO THE DFP-8000• PRECAUTIONS IN WIRING o z A. IN THE CIRCUIT DIAGRAM ABOVE, THE EXTERNALLY CONNECTED 12V RELAY IS DRIVEN VIA C. ISOLATE THE RELAY COIL AND THE CONTACT CABLE. THIS MAY REDUCE THE IMPACT FROM 0 z 0 EQUIPMENT THE RELAY CONTACT OF THE DFP-8000 AND THE 12V RELAY CONTROLS THESWITCH EXTERNAL AND ENSURE ELECTRICAL ISOLATION. IN ADDITION, CONNECT O CONNECTED TO THE POWER CIRCUIT. TWISTED-PAIR CABLES TO THE CONTACT AND THE COIL. THIS MAY ALSO REDUCE THE F GROUNDS ¢o n � B. BE SURE TO INSTALL DIODES TO THE RELAY.COILS FOR ABSORBING SURGES. IF A SURGE M OCCURRENCE AND IMPACT OF NOISE. LL CAUSED BY A COUNTER-ELECTROMOTIVE FORCE OCCURS, AN ERROR MAY OCCUR IN THE RELAYS USED FOR TURNING ON/OFF THE ROOM LIGHTS AND WARNING LIGHTS, MUST BE SAMME SIZE AS PHASE CONDUCTORS.OUND ELECTRODE PER NEC 250-30(A) DFP-8000. USE A DIODE WITH A RATING OF 1000V AND 1A FOR ABSORBING SURGES D. FOR THE CONTROL CIRCUIT OF THE ROOM LIGHT OPEN/CLOSE SWITCH, USE THE POWER � WILDING STEEL, WATER PIPE, OR GROUNDING ELECTRODE AS CLOSE AND USE A DIODE WITH A RATING OF 2000V BETWEEN THE COILAND THE CONTACT. SUPPLY ISOLATED FROM THE ROOM LIGHT CABLE. IF THE ROOM LIGHT CIRCUIT IS PHYSICALLY POSSIBLE THE DISTRIBUTIONIASNDUCTORS UNIT. GROUND DIRECTLY CONNECTED TO THE RELAY CONTACT CONNECTED TO THE DFP-6000, NOISE MAY STANDARD POWER QUALITY NOTES- EASILY ENTER DEPENDING ON THE ROUTING. TO PREVENT SPARKS FROM OCCURRING AT THE RELAY CONTACT, INSTALL APPROPRIATE SNUBBER CIRCUITS TO THE SWITCH COIL W A. A GROUNDED NEUTRAL POWER SOURCE IS REQUIRED TO ASSURE RELIABLE EQUIPMENT.OPERATION. THE NEUTRAL CONDUCTOR MAY NOT BE USED FOR A PARTICULAR SYSTEM. N m B. IN CASES WHERE MULTIPLE VOLTAGES ARE PERMITTED,THE PREFERRED SYSTEM VOLTAGE IS SPECIFIED. EE � _- O C VOLTAGE SOURCE. INSTANTANEOUS NEHH LOWER VOLTAGE MEDICAL ARE DERIVED DSE THEY FIROMST AV IILABLE CB / PCDU-100VL WIRING DETAIL *2ELECTRICAL LIGHTING CONNECTIONS DIAGRAM ENTRANCE of THE FACILITY. W w f I-D. GROUND CONDUCTORS ARE REQUIRED TO BE THE SAME SIZE AS THE PHASE CONDUCTORS UNLESS A J � � 0 O SCALE: NOT TO SCALE 11-06-14SCALE: NOT TO SCALE 11-06-14 LARGER SIZE IS REQUIRED BY CODE. NOTE,•' E. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS MUST BE COPPER -ALUMINUM IS NOT PERMITTED. I- W Q � z y '� F. IF THE EQUIPMENT CIRCUIT BREAKER IS NOT LOCATED IN THE CONTROL AREA, A SHUNT TRIP BREAKER /Q W CUSTOMER'S CONTRACTOR TO VERIFY LOCATION - �,/� MUST BE USED IN ORDER TO COMPLY WITH N.E.C. 517-72(B). A PUSH-BUTTON TO OPERATE THE . SHUNT TRIP MUST BE LOCATED IN THE CONTROL AREA. 'Z X 0 0 OF J-BOX(ES) FOR CABLE PULL TO WALL DUCT. /''l G. G. A SEPARATE CIRCUIT FED FROM THE FACILITY RADIOLOGY PANEL OR A MAIN SERVICE PANEL IS W CUSTOMER'S CONTRACTOR TO VERIFY LOCATION PERMITfE•USE OF A SUB PANEL WITH LOADS SUCH AS ELEVATORS, HVAC, MOTORS, ETC., IS NOT Z Z OF GROMMETED OPENINGS IN WALL DUCT WITH .�� ,/� TOSHIBA REP. `.T.�` W O H. DEVICES SUCH AS UNINTERRUPTIBLE POWER SUPPLIES POWER CONDITIONERS VOLTAGE REGULATORS, GROMMETED OPENING OR �o j �� 6" AND FILTERS MAY BE INCOMPATIBLE WITH THIS IMAGIND EQUIPMENT. CONSULT YOUR TOSHIBA SERVICE c Z _ W SURFACE MOUNTED WALL REPRESENTATIVE PRIOR TO PURCHASING OR INSTALLING THESE.DEVICES. SPLIT ACCESS COVER ON �''' °�.,� CONDUITS) ABOVE _ ,w Q J J (� FACE OF WALL DUCT. DUCT WITH EQUALLY I - I FINISHED CEILING. 18" X 12" X 6" J-BOX, I. THE MAINS POWER GROUND CONDUCTOR IS TO BE RUN WITH THE POWER PHASE CONDUCTORS. THE v/ V Q SPACED PARTITIONS SURFACE MOUNTED TO WALL GROUNDS TO BUILDING STEEL OR EARTH GROUND ARE NOT TO BE RUN WITH THE PHASE CONDUCTORS. W 0 W LL THROUGHOUT W/ PARTITION I I J W TE: CUT-OUTS AT OPENINGS. J-BOX FLUSH MOUNTED - W 12" X 12" X 4" J-BOX, 1 m O Z a'FOR SECTION IN FINISHED CEILING. A @� FOR ALL WALL NOTE: FLUSH MOUNTED IN WALL. A L Q � � � DUCT CORNERS. SEE ELECTRICAL DUCT � � SYSTEM DAMAGE MAY OCCUR LEGEND REMOVABLE COVER. 10" W X 3 1/2" D, SURFACE 200% ABOVE ( ) ~ Lu NUMBER(OF EQUALLY '2�3- DAMAGING IMPULSES y O O SPACED PARTITIONS WITHIN MOUNTED VERTICAL RISER DUCT. NOMINAL VOLTAG oo E " DUCT (THREE SHOWN FOR O: REFERENCE). ,8" W X 3 1/2" D, SURFACE Q 0 J-BOX FLUSH MOUNTED IN FINISHED CEILING MOUNTED WALL DUCT. r I I NOTE- SYSTEM DISRUPTION FLUSH MOUNTED J-BOX MAY OCCUR '"�.,•' �,, (OPEN TO WALL DUCT) ,. - CORE DRILL THRU FLOOR. 100% ABOVE (DISRUPTIVE IMPULSES) SYSTEM DAMAGE MAY OCCUR THESE TOSHIBA PLANS ARE FOR - ^ NOMINAL VOLTAGE (HIGH VOLTAGE, SWELLS, & SURGES) INFORMATIONAL PURPOSES ONLY "PCDU" AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT It J-BOX SURFACE MOUNTED AGREED UPON BETWEEN TOSHIBA GROMMETED ' TO UNDERSIDE OF FLOOR. iV AND THE cpsrOMER.THESE SITE OPENING LOCATED 4 Yr, i i PLANSFOR ARE NOT TO BE USED T ON PURPOSES. ON BOTTOM FACE ( `'' +10% ABOVE NOMINAL OF WALL DUCT. N DATE: 05-13-15 /\ NOMINAL VOLTAGE ---------------------------- - ----------------------- -------- I CONDUIT(S) BELOW FLOOR. dip \ 1 SCALE: NOT TO SCALE -10% BELOW NOMINAL ' ACCEPTABLE VOLTAGE RANGE SYSTEM DISRUPTION MAY OCCUR PLANNER: L.B.C. REMOVABLE �'' ` (LOW VOLTAGE, SAGS, & OUTAGE) COVER. REMOVABLE COVER ON SID: 30027352 UNDERSIDE OF BOX, p NOTE, PROJECT N0. SUGGESTED MOUNTING OF J LOCAL FOR 10 US 100 US 1 mS 10 mS 100 mS 1 Sec 1 Min 1 Hr 150015249VLF1 J-BOX SURFACE MOUNTED UNDER FLOOR �"PCDU-100VL" OR AS PER LOCAL CODE. TYPICAL DUCT DETAIL WITH 3 WALL DUCT/J-BOX/VERTICAL RISER QI TYPICAL J-BOX DETAILS 5 TYPICAL PCDU J-BOX MOUNTING 6 POWER REQUIREMENTS WITH PCDU - �� SCALE: NOT TO SCALE 11-06-14 SCALE: NOT TO SCALE 11-06-14 O SCALE: 1,. = 1,_0,. 11-06-14 O SCALE: NOT TO SCALE 11-06-14 OTE: A. THE FOLLOWING CABLE DIAGRAM IS FOR REFERENCE ONLY AND MAY NOT CONTAIN THE EXACT EQUIPMENT SHOWN IN THE ATTACHED DRAWING PACKAGE. B. I.P.M. IS RESPONSIBLE FOR ENSURING THAT CABLE - LENGTHS MEET THE SITE CONDITIONS. THE I.P.M. IS L' RESPONSIBLE FOR ORDERING THE REQUIRED CABLES TO MEET EXISTING/PROPOSED SITE CONDITIONS. 0 I I , C. THIRD PARTY ITEM CONNECTIONS TO BE VERIFIED WITH INSTALLATION PROJECT MANAGER. , D. POWER AND SIGNAL CABLES MUST BE RUN IN C) �1I I; SEPARATE CONDUIT. REFER TO SHEET E2. MIC ESD CCB C880 CAT MS CAS PC DFP RAID INV WCU CC SPOWER YSTEM s� "'". N tm RUN CONNECTION O LTR. (POINT TO POINT) REMARKS m A "C880" T "PC" (55'- ") - (HIGH'VOLTAGE) -.:.:._ --- ------ -- A C880 PO EXTENDED CABLES NOT AVAILABLE J "C880" T "CAS" (65' 7") - (SIG AL & POWE ) O O (HIGH VOLTAGE CABLES) B ---" EXTENDED CABLES ARE NOT AVAILABLE "C880"T "DFP" (88' 7") - (SIGNAL & POWER) ``'�� z m of C ----_ ----" - -- - .. -__--- ---- --- --- OC C88 DFP EXTENDED CABLES ARE NOT AVAILABLE J J CA "C880" T "WCU" (75' 0") - (COOLANT) ( n O EXTENDED HOSES NOT AVAILABLE W ,a„., OD C88 WCU (COOLING HOSES) U) "C880" T "CC" (75'- ") - (C00 NT) d E - - -_,.-_ EXTENDED HOSES NOT AVAILABLE (COOLING HOSES) "MS" TO "DFP" (78'-8') (SIGNAL & POWER) F MS DFP EXTENDED CABLES ARE NOT AVAILABLE 3 - ;"CCB" TO (52'- ") IVUS (38-2") - (SIG AL) 101'-8" MAX. SYSTEM CABLE o a w T. 38'-2" MAX. IVUS apNO"CAT" TO 'DFP" (59'-0") (SIGNAL POWER) U VH EXTENDDTHIS L TO 75-5E GROUP C MAX.AN E w Z"CAT" TO CAS" (55'-9") - (SIGNA & 0THIS CABLE GROUP CAN BEEXTENDEDTO 72'-2" MAX.(85'- ") - (SIGN L) THIS CABLE GROUP CAN BEzy EXTENDED TO 101'-8" MAX. a w(75'- ") - (SIGN L & POWER az — ---- OK CCB DFP EXTENDED CABLES ARE NOT AVAILABLE Q "DFP" TO "POWER SY �I" �'' � ;) - (POWE ) o z V POWER THIS CABLE GROUP CAN BE OL DFP SYSTEM EXTENDED TO 55'-9" MAX. "DFP" TO " I, OW R) a M O M OM DFP WCU EXTENDED CABLES ARE NOT AVAILABLE o N L. "DFP" C" - (SIGNA) o 0 0 IN ON DFP CC EXTENDED CABLES ARE NOT AVAILABLE Qo a W - (SIGNA) N OO DFP INV EXTENDED CABLES ARE NOT AVAILABLE W "ESD" TO "DFP" (78'-8") - (SIGN L P EXTENDED CABLES ARE NOT AVAILABLE N m "MIC" TO 'MS" (95'-11) - (SIGNAL) Q '�' OQ MIC MS EXTENDED CABLES ARE NOT AVAILABLE LL_ (n R "DFP" TO "RAID" (42' 7") - (SIGNAL & POWER THIS CABLE GROUP CAN BE J LLJ 3: OR DFP RAID EXTENDED TO 91'-10" MAX. J G 9H w Qoo Z V W O > X .J ul Z C9 z w p a z Z J uj J —i W O z W g L6 _ � ~ N O o OWG C� 00 z C L6 THESE TOSHIBA PLANS ARE FOR INFORMATIONAL PURPOSES ONLY AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN THAT AGREED UPON BETWEEN TOSHIBA AND THE CUSTOMER. THESE SITE PLANS ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. DATE: 05-13-15 SCALE: NOT TO SCALE PLANNER: L.B.C. SID: 30027352 PROJECT NO. 150015249VLF1 OCABLE LENGTH DIAGRAM (FOR INTERNAL USE ONLY) SCALE: NOT TO SCALE L� 11-06-14