Loading...
HomeMy WebLinkAbout25-0089 961 Gregory Way City Approved Job Site Plans o EAGLE RIDGE CONSTRUCTION _ Nol°1a'1s°wo'w oxo IRC SECTION R401.3 FL Ewa°=° SURFACE DRAINAGE SHALL BE DIVERTED 6a.00' LOT h BLOCK 5 TO A STORM SEWER CONVEYANCE OR of =Fpwo GALI5TOGA 5PRIN65 5UBDIVI5ION OTHER APPROVED POINT OF COLLECTION LOT b 961 911 6REGORY WAY THAT DOES NOT CREATE A HAZARD. I BLOCK 5 I w TWIN FALLS, IDAHO LOTS SHALL BE GRADED TO DRAIN WATER Cn m= AWAY FROM FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 L Lj 10'EASEMENT LOT SIZE 0.11 ACRES INCHES WITHIN THE FIRST 10 FEET. LOT ---------- ---------------- -----------------;�-------------------- � LINES LESS THAN 10'FROM FOUNDATION TO L ZONE R-4 n R-4 ZONE w CODE COMPLIANCE 2018 IRC BE 2%SLOPE MINIMUM FROM FOUNDATION. fo C) Cn NEW CONSTRUCTION n 5' SIDEYARD SETBACKS Nw 51NGLE FAMILY DWELLING 20' FRONT SETBACKo ROOF 5URFAGE AREA 2980 S.F. ZO' REAR SETBACK �` O J BACK PATIO SLAB J O O DO NOT DRAIN STORMWATER ONTO ADJACENT 159 S.F. 20'SETBACK W EXTERIOR WALL PERIMETER 255 L.F. PROPERTIES. LANDOWNERS ARE RESPONSIBLE FOR Q- ow EAVE PERIMETER 296 L.F. @ 16" EAVE STORMWATER RUNOFF FROM THEIR PROPERTY. -----------------------------r---— —T— -------------------- �~ ' CITY CODE 10-11-8(A)BUILDING SITES SHALL USE I I BEST MANAGEMENT PRACTICES(BMP'S)TO RETAIN a AS MUCH STORM WATER AS POSSIBLE ON THE SLOPE GRADE AWAY 1 PROPERTY. SEE IDAHO CATALOG OF STORM WATER I - ° I d - d I FROM FNSIDES) D.E) 10'(ALL 1 BEST MANAGEMENT PRACTICES. I ° ° - I DATE:rvov.2o24 LO DRAWN BY:G.J. d - JOBk74-192ER-LOT b.PL F\---------- I I I \ \\ d F.F.ELEVATION @ 15Ll " ftl/11INT HOMELCATION ------al I awwNBuildings shall have approved address numbers,or approved buildingIdentification placedAll buildings shall have a permanently posted address,which shall be placedat each driveway entrance and be visible from both directions of travel alongTHE ELAN SHALL VESTA TING SITE WORK. ORK NOT SP CONSISTENT WITH THESE PLANS BEFORE STARTING WORK.WORK NOT SPECIFICALLYDETAlLED the road.Buildings shall have approved address numbers,or approved � I / I CL SHALL BE CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS building Identification placed in a position that is plainly legible,visible fromLDETAILED.ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL the street or frontage road fronting the property and of a contrasting color(IFCBUILDING CODES AND CURRENT ADOPTED LOCAL CODES. SOS 1 IRCH\ /WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER Address size is based on distance from the street:up to 50 ft.is 4 in.,51 to ISCALED DIMENSIONS AND GENERAL NOTES.THE ENGINEERIDESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED 100 ft.is 6 in.,101 to 150 ft.is 8 in.,151 to 200 ft.is 10 in.and greater is 12 in IIIZ THATARE DIFFERENTTHAN SHOWN,IF DISCREPANCIES ARE FOUND IN THE - 1 32 S.F.GONG.PADPLANS OR NOTES,OR IF AQUESTION ARISES OVER THE INTENT OF THE PLANS ORNOTES.CONTRACTOR SHALL VERIFYAND IS RESPONSIBLE FOR ALL DIMENSIONS(INCLUDING ROUGH OPENINGS). -- _— ——� - Z L_--a ----� ° a 14 I dl GRYOINC-NOTEc_ d 4 d ° V N VERIFVALL UTILITIES BEFORE DIGGING.HOOKUP WATER AND SEWER ° I ® d SERVICES TO EXISTING TAP UNLESS SEPTIC SYSTEM AND WELL ARE TO BE ffi m x INSTALLED. ° - - ° d B - d° a I I I Z m o GRADE LOT IN SUCH A MANNER THAT RUN-OFF FROM HOUSE DRAINS AWAY -° - - - d KN- D J FROM FOUNDATION AND RETAINED ON THE PROPERTY PER CODE d Q d ° tOt W REQUIREMENTS. ° - FINISHED FLOOR LEVEL TO BE 15"ABOVE CURB IF APPLICABLE. d _a - ° I I 8'�b" ,� 'V 4 d.d BNILOING ENERfV CODE COMPLIANCE 11j ° - d. 961 m HEAT LOSS CALCULATIONS SHALL COMPLY WITH THE REQUIREMENTS OF A fully visible m ° a d d I I I J REGIONALAND LOCAL CODES.PORCHES,DECKS,FOUNDATION,FIREPLACE N W ° Q ° d d I I 11 LLl ENCLOSURES,AND GARAGE AREAS NOT INCLUDED IN LIVING AREA.ALL EXHAUST FANS TO BE VENTED DIRECTLY TO THE EXTERIOR.ALL Z V d d d I I I � PENETRATIONS OF THE BUILDING ENVELOPE SHALL BE SEALED WITH CAULK QQ ° OR FOAM. temporary address Q Q Q ° 11 ° 4 ° ° -dd PRESCRIPTIVE ENERGY CODE 0O °.. - ° °d ° ° ° d I I LL •'R-301N FLOOR •"R-201N WALLS sign shall be posted ow aIa d ; J •"R-38 MIN.IN ATTIC �g�g 1 •'.35 MIN.LOW-E WINDOWS S -L _ d °d d °d on all construction ° `--- -- -- - 20'5ETBAGK L-- �---- r- ° SINGLE FAMILY RESIDENCE- sites and remain in ° ° d °d ° 15'EA5EMENT MAIN FLOOR 1522 S.F. - d SLOPE GRADE AWAY WHILE EVERY EFFORT HAS BEEN MADE TO PERFORM A FRONT PORCH 30 S.F. place I a Ce until the ° FROM FND.6"IN 10'(ALL COMPLETE AND ACCURATE PLAN REVIEW,IT DOES NOT BACK PATIO 143 S.F. SIDES) EXEMPT THE DESIGNER OR BUILDER FROM CODE GARAGE 601 S.F. d Q REQUIREMENTS OMITTED FROM DRAWINGS THAT ARE TOTAL 2296 S.F. permanent address ° d °d CONCRETE CAUGHT DURING FIELD INSPECTIONS. ° ° DRIVEYtAY (1 9T2 S.F. is in place. w LU w TABLE OF CONTENTS CURB E�V d OATION @ °a d a° SITE PLAN 1 FOUNDATION PLAN 2 � N 01°18'13°W CITY APPROVED PLANS FLOOR PLAN 3 65.00 L am, mw, BRACING PLAN 4 PANS MUST BE ON 100 SRE ROOF FRAM.PLAN 5 m FORALLINSPECFIONS ELEVATION5 6 GREGO 1N RY AY -- - - - - - - - - - - - - - - - - - - - - - - - rc SITE PLAN w SCALE 3/16"=1'-0" w THE PAPER SIZE NEEDS TO BE 24"x 36"TO SCALE PROPERLY 0 casey jevlseH draftiH9 O 1""&ge-ilq-of 16 FOUNDATION NOTES: ? uv3,~urc o=F o VERIFYALL WINDOW AND DOOR ROUGH OPENING SIZES BEFORE FORMING BLOCK OUTS AS rc°� ao'j eQ op NECESSARY. PROVIDE EXPANSION JOINTS AS NECESSARY IN ALL FLATWORK. x Frca COORDINATE ALL SIDEWALK LOCATIONS WITH HOMEOWNER. ALL FOUNDATION WALLS SHALL BE MIN.3000#/SQ.IN.COMPRESSIVE STRENGTH @ 28 DAYS. L € 14' 12'-6" 2'-6" ANY PORCHES,PARKING SLABS,STEPS AND GARAGE FLOOR SHALL BE MIN.3500#/SQ.IN. !I I ' 14'1" COMPRESSIVE STRENGTH @ 28 DAYS. cn BOxi'Kpo`DFEOP MIn. Z m 1/2"X 10"ANCHOR BOLTS @ 4'O.C.MAX.EACH SECTION OF SILL PLATE MUST HAVE MIN.(2) 1 L L ANCHOR BOLTS MAX.DISTANCE FROM END OF ANY SILL PLATE SECTION TO ANCHOR BOLT SHALL --------------------- � BE MIN.12". J L PONY WALLS TO BE 2 X 4-S @ 16"O.C.W/PRESSURE TREATED SILL PLATE AND DOUBLE TOP V 6 1/4"I PLATE. U' C1 ROOF/SECOND FLOOR BEARING AND PONY WALLS TO BE SOLID BLOCKED IF RUNNING Q 2 PERPENDICULAR TO JOISTS AND FRAMED TO SUBFLOOR WHEN RUNNING PARALLEL TO JOIST. Nis® �wH ERREDL eAove��• C—) m L LOGAiion55Mown LOMPALTEDGRAVEL 8A5e INSTALLS I'S PER MANUFACTURERS RECOMMENDATIONS INCLUDING ALL BRIDGING AND v } -------- — I BRACING. J I — r I _ ANY NAILS THAT PENETRATE CONCRETE OR PRESSURE TREATED LUMBER TO BE HOT DIPPED GALVANIZED OR EQUAL. I I I I EXCAVATE TO MIN.30"BELOW JOISTS.INSTALL 6 MIL.VISQUEEN VAPOR BARRIER IN CRAWL N a e SPACE. .. J — — L•—————————————— SEE BRACING WALL PANEL FOR HOLD DOWN LOCATIONS AND DESCRIPTIONS. VENTING RATIO TO BE 1 SO.FT VENT/1500 SQ.FEET OF CRAWL SPACE IF UNCONDITIONED. zx4PonrvuLL or<R I L-- 'Fu_vu�LSN - ALL OPENINGS IN THE EXT.BLDG.ENVELOPE SHALL BE SEALED AGAINST AIR INFILTRATION.THE DATE:NOV.2024 FOLLOWING AREAS MUST BE SEALED. — — — •' DRAWN BY:G.J. JOINTS AROUND WINDOW AND DOOR FRAMES •"JOINTS BETWEEN WALLANDT BETWEEN WALL I TY FOUNDATIONW OB#24�PLER-LOT •"JOINTS BETWEEN WALLAND ROOF •"UTILITY PENETRATIONS THROUGH EXTERIOR WALLS GRADE SLOPE:6"DROP WITHIN FIRST 10'FROM FOUNDATION. I •� I I I I I .. I �XB"x�D'FOOTING Eft I I — — — 1 — — — — CS HDftS. 30' 3' 3' — 9 1/2" BUS @ 16" O.C. z I I BOW SERIES BGS I � I - FLObOF J�OI50TV5BmE G]4"�Mln - B EDGE OF FOO ING M Q] I •• 4 I / I I - � \ — — — D%4 POnYwAi1OVER Bb"BL�KO � i •. E— AO 5 PAN II = I I - o I I r a m I TIT "_________—.p— r �` Y L�T1111�T II L L—_ �� RU55BEARnGP°NYMPLL D d s�eF oaR neeuEpl xTo L CROSS SECTION I - I E ERDftPNIBH GYP —————————— NOT TO SCALE As sPE4 1a- .BOARD iYP FINIS H— SH __--__--__ f 10'b"�� ~ gmx COVERED POR H I • I - lvaiERPrs'° R-�DINSNL,TI°N N S N o 40cr°PAcc:eo�R`nsve ER4 BMAN BuaDinpPAPE�R r'LONLRSTEFOUNDAn°NpwLL Z >N L PED ((1 VE�BAR5(gnnn0005 HOR O N J OO ft SHEAR YYLL .4B'D.L.MPX Z waLL PY 1IT x6p AB® 1x EXP.JOINTS®PERIMETER Iw N 2 OONITED GRnVE 4ovE V P p OP FnD. R I I UUD15iUR.IIO RTH Q N I o 1 GARAGE w —0-0—OOMPw-rEeaAVEI.. m I I AMETERANL 130 T SLOPEY'TOOM GAR GE -Ili X OI' Lu EFALED IN EOUPL tp S `l Ix 1 WlSHERSOLEFLATEiAu _ 5 I I TYP. GARAGE DETAIL p-N POST SCALE:516"-l'_0" I I z I I I I Q I I Iel J I L1 E • I (SEE PLAN)MIN 1/I'GYP.BOARD nP.FIn15H XTEWOft FINISH f -------------------------- 51MP50N P05i BASE llib'OS B.W ]Xb'G®16'OL O I�LONLRETE SLAB rv1�nGPR� STUD WALL 11'-11/2" 10'-41/2" 3' 24' coLUMN GZE wFCLuv NG Bu1 SHEARS ]fib P.rx tm ABre ..® 3l4"TBGObB.FLOORInb ANY MA50NRY /Oo- 3ELO.ROST �d01n5UL5iON BE1wEEn ]x�P�nYwAi1 STUDS - 4 _I I'II rmmR C-,III E 016 0G FT. V GONORETE LOn N LA1E LINE jlll1111111I ——- o BOT FTC._ d a JII—Ili_m --ri — AGO WHEN VAP mIL P w=BnRS�LOMT11-5) O _ FOUNDATION PLAN �PUNllll m_I Ill�E °R NO.— FOUNDATION ILL SCALE 1/4"=1'-0" B x16-cones FomlNG cm TYP. P05T& PIER DETAIL GRI=Dnl CITY APPROVED PLANS NOT TO SCALE mw".^/^"ro^"B^--- BUILDING SSG. DETAIL PANS MUST BE ONIOB SITE FOB ALL INSPECTIONS W SCALE:3/8"=1'-0" x N THE PAPER SIZE NEEDS TO BE 24"x 36"TO SCALE PROPERLY 0 casq jevlsevi draftivig (o Fl"et2-of 16 o moo 10'-6 " 2'11' 14' 12'6 -6" z j�5 z 151 - !L !r CL CL CL Smoke Detector location: MISCELLANEOUS NOTES w .Hn�'.aFrca 5'-b" 4'-b j-4'41/2­-j-5'-11/2"- 6'-01/4" b'-s 3/a'• Smoke allnoteialarms and smoke detectors STRUCTURAL IC RESPONSIBILITY MANUFACTURER, TRUSS INTEGRITY VERIFY ALL shall not be mSSBIIed Wltllln 36" STRUCTURAL SPECIFICATIONS W/MANUFACTURER,TRUSS VENDOR OR ENGINEER. horizontal path from the tip of the blades LJ.J CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO BUILDING. Cn m v of ceiling-suspended fan. 4 COORDINATE ALL INTERIOR AND EXTERIOR FINISH,MATERIALS AND COLORS WITH HOME Z °xb Eos ` ° " ex°Fosr OWNER. L L L 1 N �r J KITCHENANDBATHROOM DESIGNS AND LAYOUT AAPER.OWNER. 4 BATH AND RANGE HOOD FANS INDICATED SHALL VENT TO OUTSIDE AND MEET ALL U-1 ow etector location: OVERED PATI " �I REQUIREMENTS OF THE 20181RC.AND BE SMOOTH PIPING WITH MIN.50 CFM. Cn I arms and smoke detectors 9'1 198"CLNG. o 91= be installed within a 36" VENT DRYER EXHAUST TO DUCT IN WALL AND VENT OUTSIDE. Q FROM F.F.- x l path from the supply register P PP Y 9 ALL WINDOW AND EXTERIOR DOOR HEADERS ARE(2)2 X 10'S OR EQUIVALENT UNLESS d air heating or cooling system OTHERWISE NOTED. I` be installed outside of the WINDOWS MARKEDAS EGRESS SHALL MEETTHE 20181RC.MIN.REQUIREMENT.�_c low from those registers. O *� WINDOWS SET @80"UNLESS OTHERWISE NOTED. 4Dabls `x 4os�1x THE IPC REQUIRES A CRAWL SPACE ACCESS WITHIN 20 FEET OF ALL UNDER FLOOR CLEANOUTS. O DINING ROOM I Sim all be at leALLCRAWLSPACE AND ATTIC OPENINGS TO BE 22"X 30"UNLESS OTHERWISE NOTED. 9'1 1/8"CLNG. Yoorway,un5/8"TVP."X"SHEETROCK ON CEILINGSAND WALLS BETWEEN GARAGEAND LIVING SPACEScement ofINCLUDING BONUS ROOMS.(51zxtDHOrsS. DATE:NOV.2024 y NFPA 72 GARAGE DOOR HEADERS TO BE INSTALLED PER WALL BRACING SCHEDULE.(VERIFY SIZING O W/TRUSS VENDOR OR ENGINEER ON OPENINGS WITH ADDITIONAL LOAD ABOVE HEADERS DRAWN BY:G.J. SUCH AS DORMERS AND SECOND FLOORS ETC.) BEDROOM 4 I JOBx24-192ER-LOT 9'1 1/8"CLNG. _ _ For tray-shaped ceilings(coffered ENTRY DOORS FROM GARAGE TO HOUSE TO BE 20 MIN.LABELED SELF CLOSING HINGES. 6.PL T 1 I w Dw 5 ceilings),smoke alarms and smoke FIRE CAULK ALL PENETRATIONS ON COMMON WALLS FROM MECHANICAL. detectors shall be installed on the ELECTRICAL RECEPTACLES IN BATHROOMS,KITCHENS AND GARAGES SHALL BE G.F.I.OR C50 -- m rl 4/1]GEILInb F.I.C.. PER NATIONAL ELECTRICAL CODE REQUIREMENTS. I I�I 51f- -I- FITGH highest portion of the ceiling or on the r-2 v2" 3•-5 vz' °I 5 LIVING ROOM - sloped portion of the ceiling within 12" zoe5 sT,� b g 1 1/8"PLATE HT' Iu PRIMARY BEDROOM NFPA(Chapter 29)Smoke alarms Shall not be Installed In I ULATE ALL ACCESS DOORS/HATCHES TO CRAWL SPACES AND ATTICS TO THE D tr vertically down from the highest point. E UIVALENT RATING OF THE WALL,FLOOR OR CEILING THROUGH WHICH THEY PENETRATE. X VAULTED 9 9.1 1/8"CLNG. the following locations unless this would prevent placement O ON PLANS. _ _ 1 3.-I. Please reference NFPA 72 Chapter of,a smoke alarm. ATTIC R-38 Y GLOSETROD86MELVI"G KITCHEN 29.w 1.lonization smoke alarms shall not be installed less than WALLS R-30 Tempered FLOORS R-30 P I I s'1 v6• I I I I CD 20'horizontally from a permanently installed cooking J CLNG. L__ J I I�I I ��o appliance. P VIDE IMPACT PROTECTION PER IRC.CODE IF MECHANICAL IS IN LINE OF VEHICLE 4s°vt`nHl"tt� p 2.1onization smoke alarms with an alarm silencing switch KING IN GARAGE. rt y a R315.1 Carbon monoxide alarms.For shall not be installed less than 10'horizontally from a BAT H new construction,an approved carbon permanently installed cooking appliance. rK 9'1 1/8"CLNG. 5'-10" 2'-6112'• 6'-6" U-51/2" a-2° a'-b•' _ monoxide alarm shall be installed 3.Photoelectric smoke alarms shall not be installed less �' boo 3068 - ILAT outside of each separate sleeping area than 6'horizontally from a permanently installed cooking -- in the immediate vicinity of the appliance. n m - yNG ® bedrooms in dwelling units within which fuel-fired appliances are installed and in aosET BODaSHELVI"G Q ENTRY II Z = dwelling units that have attached CLNG. PRIMARY I< ara es.v ;,� cwsET aoDasHELVIHv > 9 9 r , n �— BATH I•� - Y LAUNDRY - 9'11/8"CLNG.L - 1/Y b'-7' 9'11/8"CLNG. I C L Fnrv� ge �� CD AGGEbb 3055E"rar _ w 9'11/8"CLNG. BEDROOM 2 9 9111/8"CLNG. BEDROOM 9'11/8"CLNG. �COVER D m55 (�)1xtD MDaS.-8'-41/2" 5'-11/2" 1'-[F1 PORG uEELED SELF 9'11/8"C N os Nb MwbE DooR 'o N. WH FROM F F. A(J - Z O MEGH. I 1 � OTo55 FIREM AUW= 405p5H GOMMO MEC H. EROM p_—ry LL N I I I �dLL W I I I I q PN 3 GARAGE 9'1 1/8"CLNG.FROM F.F. W III.,ttP."X"5HEETROCiK ON CEILINGANDCOMMON I� gg WALL 5 IN GARAGE S e LEGEND. LU W CD SMOKE DETECTOR 3 Cho CARBON MONOXIDE/SMOKE DETECTOR F� FAN UNIT - O TEMPERED GLASS WINDOW SCHEDULE LABEL O 20116FX 1�TM 2016FX 5HOWER SIZE ROOM ME COMMENTS EGRESS WINDOW 20365HI 1 0365H BATH 4040 1 4040 BEDROOM 4 4050FX FX 2 4050FXFX GARAGE ® BEARING WALL 4050 2 4050 LIVING ROOM/COVERED PATIO 40505H 5H 1 40505H5H BEDROOM 2 Z 40505HI 1 40505H BEDROOM 3 5050L5 1 5050L5 DINING ROOM SOSOLS 1 SOSOLS PRIMARY BEDROOM QJj 4011x 11111 a 5-5 3/4" T-7 3/4" 5-1 114" T-3 114" 4'-0 112"--T 9'-9 3/4" DOOR SCHEDULE LABEL GTY 5IZE ROOM NAME COMMENTS 11'-11/2" 10'41/2 5' 24' SINGLE FAMILY RESIDENCE 2268 1 2265 RIN HAUNDREN O 2668 1 2668 R IN BEDROOM so•-6•, MAIN FLOOR 1530 S.F. 2668 1 2668 L IN BEDROOM 7/HALL O FRONT PORCH 30 S.F. 2668 1 2668 L IN BEDROOM 3/HALL BACK PATIO 143 S.F. 2668 1 2668 RIIN BEDROOM 4/HALL GARAGE 601 S.F. 2668 1 2668 RIN PRIMARY BATH/PRIMARY BEDROOM 1' TOTAL 2296 S.F. 2668 1 2668 RIN W LL WC/PRIMARY BATH 2868 1 2668 R IN PRIMARY BEDROOM/LIVING ROOM 5065 1 3068 L EX LAUNDRY/GARAGE MAIN FLOOR 3068 3065LIN LAUNDRY/ENTRY 306 1 3068 R EX GARAGE 3065 1 3066 R IN PANTRY/KITCHEN SCALE 1/4"a 1'-0" 5066 1 5068 RN BEDROOM 2/CLOSET CITY APPROVED PLANS 5065 1 5068 R IN BEDROOM 3/CLOSET 5065 1 5066 R IN BEDROOM 41CL05ET N.eaee wmM�^^re 1068 1 7068 R IN MECH./GARAGE PO SITE 160800.H.D. 1 16050 GARAGE FOR ALL INSPERIONS 3068 ENTRY 1 306 R EX ENTRY/COVERED PORCH X 3068 GLA55 1 30686 R EX DINING ROOM/COVERED PATIO z w T N THE PAPER SIZE NEEDS TO BE 24"x 36"TO SCALE PROPERLY 0 casey jevlsevi drafting (oRageog_of 16 o moop �r. wy�w�=w TABLE R602.10.3(2) I I ALTERNATE ATTACHMENT5 TO TABLE R602.3(1) SPADING OF FASTENERS Z a NOMINALMATERIAL DESCRIPTIONOFFASTENER EDGES INSUPPORTSE F I I m 48' 2'-6" THICKNESS(INLHE5) AND LENGTH(INLHE5) (INLHE5) (IN-es) U, n WOOD STRUCTURAL PANELS EUBFLOOR,ROOF B WALL 5HEATHING Z TO FRAMING A PARTICLEBOARD NULL 5HEATHING TO FRAMING V-53/4" 15'-01/4" 3' 10'-10112" 5-11/2" 8'-b 1/4" 3'-113/4" 1 up To 1Y1• 0-74,99 NAIL 2114 3 b 1 L I ` TABLE R602.10.5 U) 48' 4 a MINIMUM LENGTH OF BRACED WALL PANELS Q. M E GTH U INI o_E57 COVERED PATIO NErHov WALL HE— CONTRIBUTING LENGTH 14'-H'X9'-11ll' BFT 9FT LOFT 11 T 12FT (INLHE5) CS-WSP 1415a FT„ GB 4B 40 40 S3 53 a C^aG 24 2T 30 33 % ESiACTUALb `' n n � L5-PF 16 1B 20 23e 24e ooe ACTUAL /A 1`iRFQ'� s :zw csWSF.�ruc c� " necNesic� o -- —�_ �61 24 n 3o 3533 % L 13.5'PROV. — -- -- CS-WSP CS-WSP BB zb n 30 36 l2 so n 30so so 33 36 30 X 30 33 36 y DINING ROOM - 14 35 . 3o 33 . DATE:NOV.2024 BB M se 32 33 36 U 101 SQ FT CS-WSP 92 43 3T 1 35 35 36 DRAWN 8Y:G.J. 1. 48 t 44 4o a 3a JOBk24-192ER-LOT p too 43 4039 6.PL AGTuu 3 _ 1. 54 4o 43 41 112 50 45 43 BEDROOM 4 T16 ss 4B 4s 10'-2"X 10'-0" _ 1. so 52 0 105 50 FT t24 si 51 120 bt 54 132 bb 50 I 140 66 I I I Ir n °I LIVING ROOM ne.w.I w,e�Ir pr ua ra memmmum 13'-10"xib'-5'• PRIMARYBEDROOM mum Ia9Bln I:yremermaF Rug Ie9yln. 23150 FT 12'2"X 14'3" remea ro u'wI op w 2'furbto per re Rb0]t0b�4.bw wall Nelsen my be I�cn m p°N well. PROVIDE 2X4 PANEL EDGE BLOCKING®ALL 113 50 FT p KITCHEN DESIGNATED BRACED WALL PANEL LOCATIONS - 10'-2"X 13'-10' (ALL"RIP"SHEETS MUST BE iT MIN.) TABLE R602.10.30) rb �I 13050 FT L- J BRACING REQUIREMENTS BASED ON WIND SPEED U ®I -EXPOSURE LATEGORYB MINIM LL -30 FT MEAN ROOHT EIGHT UM TOTALLENGTH(PE 1— BRACED PULL PANELS REQUIRED BATH .26 RALED WALL LINES ALONG EACH BRACED NULL LINE b'-8"X 8'-0" UDESIGN L L N METHOD L5- 4550FT WIND STORY WPL E METHOD W5P.L5-G. LOCATION 5(EET) GB LS-PF -- to 55 30 WG ® Y 4 30 9.5 so Lug 4o tzs 15 ENTRY -- o 5'-3"Xe'-ll" I PRIMARY so 15a Tz 4150 FT BATH so .0 9.0 r�AUNDRY <11s5'b"XB'110l00"X 11'-5" I 45 50FT ///��� tz s 6s 250 FT L �® 7-I 30 1B0 90 -- ❑y /0 235 115 50 29.0 40 W.LG. 4 60 34s "o 6'2"X T'11" BEDROOM 2 46 SG FT 10•-0"x1o•-6" - 113 5O FT p e 3 PANEL LEGEND BEDROOM 3 " LONTINUous SHEATHING-WooDSTRUCTURAL Z 10'.2"X 10'-3" a U ® PANEL ll16"OSB PANEL ATTACHED T02X65®16" O 103 sa Fr COVER POR p L5-WSP LENGT AEREQAI—TOSALLORDINFENI-LE 4'FOR'-1' WH 3 - ft lo,%2) p 28 SGi W LENGTH1 RE—15TO ADJACENT OPENINGS ARE U ACCORDING TO TABLE F602.10.5 2 3 - MEGH. MIN.Toro LENo—(FEET)OF BRACED WOOD O a a " N STRUCTURAL PANELS REQUIRED HANG EACH 31—ED � /B OV. WALL LINE DETERMINED BY TABLE R602.10.3(1)—— —— —— —-CSWSP — —_ 305Gi FT >�O GYPSUM 'N U i60O OR O UCTURL CS-WSP PANELI EDT08oTHs1E5oF L Ga INLENGORTOONE5IVEODW1-@ b" VZI N"p-O J W K Q ® SEE FIGURE R602.1064 �LLI�I 4 LS-PF ® SEE FIGURE R602.10.6.4 - LSG V W SEE FIGURE R602.10b.2 , GARAGE ® V 13'-0'X14'-1" PFH 52150 FT W METHOD CS-PF Figure R602.30.6.4-CONTINUOUSLY SHEATHED PORTAL FRAME II I I r Q a ch t111111A—— ==r- CS-WSP CS-W P 14'-9" 3'-31/4" 5' 4' 16' aid aimI BRACING PLAN �p �p olp _ mlo 6I p SCALE 1/4"—1'-0" —.p. CITY APPROVED PLANS e..ahre°eemnwu-eM. w PLANS MUST EC IOSRE ~ FOR ALL INSPECTIONS � THE PAPER SIZE NEEDS TO BE 24"x 36"TO SCALE PROPERLY 0 casq jeviseH drafting (oFlaget4i-of 16 Sw - ,�N„. o ------ ------- ti wpaE� Fpa iXB Po 6:12 r► I I I Z �x �1 i i F--------I--T--_� i FI H". _ - co - r---------- I --- I N2.5T Installation Z L— — -----� I I I ow r,rtyN�N�Popul"„ Lu t--------- C.T� � ly \ I GIRDER TRU55 I \ \ 2 ROOF BA5E LINE \' ---------------------------------------------- \ \ I- -- ----- ---- I _�___ _____ ______ ______ ______ =6E' (5)]x to«vRs. I \\\ \\\ I /// /// I SPECIFICATIONS. USE ISER MANUFACTURERS RECOMMENDATIONS INCLUDING ALL BRIDGING&BRACING TO DRAWINGS& I FOR I INSTALL TRUSSES P \ ✓ / r ,II/UU ✓ _ ______ ______ =_-== � Po I \ I I ALL TRUSSES SHALL CAREY MANUFACTURERS STAMP. ALL TRUSSES WILL NOT BE FIELD ALTERED WITHOUT PRIOR BUILDING DEPT.OR TRUSS VENDOR APPROVAL. ALL TRUSSES SHALL HAVE DESIGN DETAILS&DRAWINGS ON SITE FOR FRAMING INSPECTION. DATE:NOV.2024 0 / 41,2LEwrvb I I \\ // i ALL CONNECTIONS OF RAFTERS,JACK OR HIP TRUSSES TO MAIN GIRDER TO BE PROVIDED BY TRUSS DRAWN BY:G.J. T — ———— PIrcH —— r MANUFACTURER. I I } -----------� IJOB k24-1R2ER-LOT 1 .I�, �9'1 1/8"PLATE HT ALL ROOF FRAMING 24"O.C.UNLESS OTHERWISE NOTED. 6.PL \ VAULTED N / / \ RAFTERS FOR OVERBUILDS PER IRC TABLE 802.4.1(3).RIDGE BOARDS 8 SLEEPERS TO BE MIN 2"TALLER THAN r / G, '� I I 6:12 / \ I RAFTERS. 2X6 STUDS UNDER ALL GIRDER TRUSSES BEARING POINTS,NAILED TOGETHER. I w \ I � Jhy�2�� ¢r I /\ N // I ALL STUDS,POSTS 8 HEADERS TO BE DOUGLAS FIR LARCH#2 OR BETTER. ALL OVERHANGS 16"UNLESS OTHERWISE NOTED. — t Q� � ' I \\ / I I VERIFY ALL BEAM SIZING WITH TRUSS MANUFACTURER OR ENGINEER TO SUPPORT ROOF STRUCTURE. // _ I I \\ // I I PROVIDE MEANS TO RESIST UPLIFT AT EACH LOCATION SHOWN ON TRUSS DESIGN DETAIL. USE HURRICANE TIES AS REQ'D AND H-CLIPS BETWEEN ALL ROOF SHEETING.PROVIDE COLLAR TIES FOR HAND FRAMED ROOF RAFTERS. rp \ b:12 \\ // I b:12 i COORDINATE EXACT LOCATION OF ATTIC ACCESS WITH MIN.30"HEAD ROOM ABOVE HATCH PER 20181RC. ATTIC VENTILATION:REQUIRED ABOVE HOUSE. IT - _ _ --- - --- -- I I - - --- -- � I I I I I 6:12 I I y IN\ - DHDRS. I I I U I I I 61RDERTRUSSNi I I 1 I I I I I I I L ----- ----- J I A=. I I I I I Z HAND STACKED 2 X 6 RAFTERS @ 24" — I I O O.C.W/2 X 8 RIDGE BOARD&SLEEPERS (RAFTERS SPANED OVER 8'TO BE I I I I I BRACED DOWN TO MAIN ROOF)TYP. I I_______ t_____— H >so In N p s i i ROOF PLAN VIEW `' W.L. LLIO 0. 5GALE 3/16"=1'-0" P o RooPl ulµiLess B• .ESH I i1, OSEETING�HERW15E5OWN q N ROOF FRAMING PLAN I I I PEROOFTe055E5®94"OL � W 56ALE 1/4"=1'-0" o ass aLENA E01 R°w ,J^ 24 I RdBINSULATION V LERIIN EACH TTAHP Lu iOP PLATE O ­ W I I I I I I 1-0 b'—CIA G ) 510'bYP.BOARD ttP.FINIS« I I I ,b'OVERHAN J// 2x610PPu1E SOFFrt VENT I I r 1 I T l l �_RAFTERS 2X8 (t6 24"O.C. I i I 1 I 1 V i�✓ o- 1 I E W a /I'Gm.BOwRD nP.FIN15H uao • oc ec er O SPEL. �•�ro 20IN5UNnOn I'll iERPwo' O.C. LDI�NG PAp EARS 2"65iU0 WALL W PPE P.T.x,O-A BTE® BU SHEAR 0AL BIq"TBGObB.FLOORInb ILL,n�.,,.b era. �.�•,.�..�.. � GR,DE P,12 ELLS®,B D.L. � •,• r 6O0TP _d01N5LUL5LO—OiON B E1WEEn ] 4P ONY O OG—FT l CONCRETE H u () O Bxt2-CONc FOIS) O WVR9I0'OLN - L0«TNO NnOU IU LTA A,-- QUEEN— IRIIRNL—L xtLONL.OSLG]) .e. CITY APPROVED PLANS .v L..o,. "ae,ea.,u.ea - R".-,",.-.efa•c "co,., ,o„=. HORao"ru PLANS MUST JOB SITE f FOR ALL INSPECTIONS TIONS BUILDING SEG. DETAIL OVER FRAMING DETAIL w 5GALE:30'=V-0" NOT TO 50ALE m THE PAPER SIZE NEEDS TO BE 24"x 36"TO SCALE PROPERLY 0 casey jevlsen drafting (oRIge-�S_of 16 o o HI H TRI noF:anTNaPbon� moop w�H�HEz�Fpa IE D:,2 Z m€ cf:) m - s.onsysussa Q° Z W s vnsun W TOP OF PLATE CJ7 9'-1 1/8" 6 12 Q ® ,°soFx ,�soFx vearica ur slums -77 TOP OF 5UBFLOOR-15T FLOOR �bbEu 0' DATE:NOV.2024 DRAWN BY:G.J. JOB k 24-192ER-LOT b.PL FRONT ELEVATION SCALE 1/4"=1'-0" 6:12 LEHI 6:12 6:12 16 0. Z LEFT ELEVATION SCALE 1/4"=1'-0" v � o H >so N ��a 6:12 O 2� Lu `D tl Q N J W W �� vu b:,2 RIGHT ELEVATION V1 SCALE 1/4"=1'-0" z LQ) r J W OIL- CITYMAPPROVED PLANS .wh.cea.tampun.. °Fx °Fx BACK ELEVATION VANRALL MUST INP—ONSRE FOR ALL INSVERIONS SCALE 1/4"=1'-0" rc � 6 THE PAPER SIZE NEEDS TO BE 24"x 36"TO SCALE PROPERLY 0 casey jevlsen drafting (o Ragetfi_of 16 WPI9htSOft s Load Short Form Job: 971 Gregory Date: 01/02/25 entire By: Precision Heating Precision Heating Project Information For: Eagle Ridge Design Information Htg Clg Infiltration Outside db(°F) 2 95 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD(°F) 68 20 Fireplaces 0 Daily range - H Inside humidity(%) 50 50 Moisture difference(gr/Ib) 58 -36 HEATING EQUIPMENT COOLING EQUIPMENT Make Bryant Make Bryant Trade BRYANT Trade LEGACY 14 SEER2 AC Model 801SA36045E14 Cond 114SAN036CONAO AHRI ref 203360134 Coil CAPM P3617ALA+88OTB4807OC1 7 AHRI ref 213455889 Efficiency 80AFUE Efficiency 12.0 EER2, 14 SEER2 Heating input 42000 Btuh Sensible cooling 22680 Btuh Heating output 34000 Btuh Latent cooling 9720 Btuh Temperature rise 33 of Total cooling 32400 Btuh Actual airflow 1080 cfm Actual airflow 1080 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) bed1 154 2906 2849 112 146 Laundry 88 1846 542 71 28 wic 56 832 220 32 11 mbath 87 1874 566 72 29 bed2 145 3378 2908 130 149 master 195 3971 3205 153 164 bath 1 64 1190 402 46 21 bed3 137 3233 2122 124 108 great 577 8853 8322 340 425 CITY APPROVED PLANS Reviewed for Code Compliance Calculations approved byACCAto meet all requirements of Manual J 8th Ed. PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS wrightsoft® At - awa.­n, Right-SLite®Uriversal 2024 24.0.01 RSU14048 Page 1 ACCA ...\Home0ocrmerds\WrightsoftHVAC\971 Gregory.rup CaIc=MJB Front Door faces:W Page 7 of 16 entire 1503 28083 21137 1080 1080 Other equip loads 3375 993 Equip.@ 1.00 RSM 22129 Latent cooling 0 TOTALS 1503 31458 22129 1080 1080 CITY APPROVED PLANS Reviewed for Code Compliance PLANS MUST BE ON JOB SITE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. FOR ALL INSPECTIONS wrightsoft® 2025-Jarr03 09:06:09 At A—k-11 1- a«awa.C­.y Right-SLite®Uriversal202424.0.01 RSU14048 Page 2 A—CA ...\Home0ocrmerds\WrightsoftHVAC\971 Gregory.rup CaIc=MJB Front Door faces:W Page 8 of 16 Building Analysis Job: 971 Gregory +� wrightsoft" g Date: 01/02/25 entire By: Precision Heating Precision Heating Project Information For: Eagle Ridge Design Conditions Location: Indoor: Heating Cooling Twin Falls AP,,ID,US Indoor temperature(°F) 70 75 Elevation: 4150 ft Design TD(°F) 68 20 Latitude: 42°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 58.2 -36.3 Dry bulb(°F) 2 95 Infiltration: Daily range(°F) - 30 ( H ) Method Simplified Wet bulb(°F) - 61 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 amme Component Btuh/ft2 Btuh %of load Walls 4.6 6660 21.2 Ventilation Glazing 23.8 3722 11.8 Walls Doors 26.5 1114 3.5 Ceilings 3.0 4497 14.3 Ducts Floors 2.4 3669 11.7 Infiltration 2.6 3766 12.0 Ducts 4655 14.8 Glazing_ Piping 0 0 Humidification 0 0 Infiltration Ventilation 3375 10.7 Doors Adjustments 0 Ceilings Floors Total 31458 100.0 • • • Component Btuh/ft2 Btuh %of load Walls 1.0 1442 6.5 Glazing 64.2 10046 45.4 Walls ventilation Gains Doors 10.3 434 2.0 Ceilings 2.2 3307 14.9 Ducts Floors 0.7 1079 4.9 Infiltration 0.4 596 2.7 Infiltration Ducts 1882 8.5 Ventilation 993 4.5 Glazing Floors Internal gains 2350 10.6 Blower 0 0 Ceilings Adjustments 0 other Total 22129 100.0 Latent Cooling Load=0 Btuh Overall U-value=0.065 Btuh/ft2--°F, Window/FloorArea=10.4% Data entries checked. CITY APPROVED PLANS Reviewed for Code Compliance PLANS MUST BE ON JOB SITE wrightsoftw h ^° °� ° Right-SLiteOUriversal202424.0.01 RSU14048 FOR ALL INSPECTIONS \Home\Doaments\WrightsoftHVAC\971 Gregory.rup Calc=MJ8 Front Door faces:W Page 9 of 16 i C Component Constructions Job: 971 Gregory +� wrightsoft°" C Date: 01/02/25 entire By: Precision Heating Precision Heating Project Information For: Eagle Ridge Design Conditions Location: Indoor: Heating Cooling Twin Falls AP,,ID,US Indoor temperature(T) 70 75 Elevation: 4150 ft Design TD(T) 68 20 Latitude: 42°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(grAb) 58.2 -36.3 Dry bulb(oF) 2 95 Infiltration: Daily range(T) - 30 ( H ) Method Simplified Wet bulb(oF) - 61 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' BtuhfflUF W-°F/Btuh Btuh/W Btuh Btuh/W Btuh Walls 12F-0sw.Frm wall,wd ext, 1/2"wood shth,r-21 cav ins,5/8"gypsum n 380 0.065 21.0 4.42 1679 0.99 378 board int fnsh,2"x6"wood frm, 16"o.c.stud a 326 0.065 21.0 4.42 1441 0.99 324 s 384 0.065 21.0 4.42 1696 0.99 382 w 182 0.065 21.0 4.42 804 0.99 181 all 1272 0.065 21.0 4.42 5620 0.99 1265 Partitions 12C-0sw.Fnn wall,stucco ext,r-13 cav ins,2"x4"wood frm, 16"o.c.stud 168 0.091 13.0 6.19 1040 1.06 177 Windows 1 glazing,clr glz,vnl frm mat, 1/8"thk: 1 glazing,clr glz,vnl frm mat, 1/8" n 7 0.350 0 23.8 171 19.2 139 thk;NFRC rated(SHGC=0.64);6.67 ft head ht e 106 0.350 0 23.8 2523 67.1 7113 s 3 0.350 0 23.8 76 34.7 111 w 40 0.350 0 23.8 952 67.1 2684 all 156 0.350 0 23.8 3722 64.2 10046 Doors 11 DO:Door,wd sc type w 21 0.390 0 26.5 557 10.3 217 n 21 0.390 0 26.5 557 10.3 217 all 42 0.390 0 26.5 1114 10.3 434 Ceilings 1613-21 ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-21 veil ins 1503 0.044 21.0 2.99 4497 2.20 3307 Floors 19A-21 bstp:Part floor,r-21 ins,fret flr,6"thkns 1503 0.045 21.0 2.44 3669 0.72 1079 CITY APPROVED PLANS Reviewed for Code Compliance PLANS MUST BE ON JOB SITE wrightsoft- FOR ALL INSPECTIONS -11.1-1-k-,.1-...11-11w Right-SuteOUriversal202424.0.01RSU14048 ACCP. ...\Home\Dournents\WrightsoftHVAC\971 Gregory.rup Calc=MJ8 Front Door faces:W Page 10 of 16 Project Summary Job: 971 Gregory Wrightsof " Date: 01/02/25 entire By: Precision Heating Precision Heating Project Information For: Eagle Ridge Notes: Design Information Weather: Twin Falls AP,ID,US Winter Design Conditions Summer Design Conditions Outside db 2 °F Outside db 95 °F Inside db 70 °F Inside db 75 °F Design TD 68 °F Design TD 20 °F Daily range H Relative humidity 50 % Ventilation Method ASHRAE 62.2-2010 Moisture difference -36 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23428 Btuh Structure 19255 Btuh Ducts(R-6.0) 4655 Btuh Ducts(R-6.0) 1882 Btuh Central vent(53 cfm) 3375 Btuh Central vent(53 cfm) 993 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31458 Btuh Use manufacturer's data n Rate/swin multiplier 1.00 Infiltration Equipmen�sensible load 22129 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 331 Btuh Ducts -210 Btuh Central vent(53 cfm) -1113 Btuh Heating Cooling Outside air Area(ft�) 1503 1503 Equipment latent load 0 Btuh Volume(ft3) 13527 13527 Air changes/hour 0.26 0.14 Equipment Total Load(Sen+Lat) 22129 Btuh Equiv.AVF(cfm) 59 32 Req.total capacity at 0.70 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade BRYANT Trade LEGACY 14 SEER2AC Model 801SA36045E14 Cond 114SAN036CONAO AHRI ref 203360134 Coil CAPMP3617ALA+88OTB4807OC17 AHRI ref 213455889 Efficiency 80AFUE Efficiency 12.0 EER2, 14 SEER2 Heating input 42000 Btuh Sensible cooling 22680 Btuh Heating output 34000 Btuh Latent cooling 9720 Btuh Temperature rise 33 °F Total cooling 32400 Btuh Actual airflow 1080 cfm Actual airflow 1080 cfin Air flow factor 0.038 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 CITY APPROVED PLANS Reviewed for Code compliance Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. PLANS MUST RE ON JOB SITE FOR ALL INSPECTIONS wrightsoft® 11 RighRSLite@Uriversal202424.0.01 RSU14048 Page 1 ACC \Home0oarnentsUrigilsoftHVAC\971 Gregory.rLp Calc=MJ8 Front Door faces:W Page 11 of 16 Manual S ComplianceReport Job: 971 Gregory +� wrightsoft" Date: 01/02/25 entire By: Precision Heating Precision Heating Project Information For: Eagle Ridge Cooling Equipment Design Conditions Outdoor design DB: 95.0°F Sensible gain: 22129 Btuh Entering coil DB: 76.4°F Outdoor design WB: 61.0°F Latent gain: 0 Btuh Entering coil WB: 61.8°F Indoor design DB: 75.0°F Total gain: 22129 Btuh Indoor RH: 50% Estimated airflow: 1080 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer: Bryant Model: 114SAN036CONAO+CAPMP3617ALA+88OTB4807OC17 Actual airflow: 1080 ch Sensible capacity: 22680 Btuh 102%of load Latent capacity: 10000 Btuh 0%of load Total capacity: 32680 Btuh 148%of load SHR: 69% Heating Equipment Design Conditions Outdoor design DB: 2.0°F Heat loss: 31458 Btuh Entering coil DB: 65XF Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: Bryant Model: 801 SA36045E14 Actual airflow: 1080 cfm Output capacity: 34000 Btuh 108%of load Temp.rise: 50 °F Meets all requirements ofACCA Manual S. CITY APPROVED PLANS Reviewed for Code Compliance PLANS MUST BE ON JOB SITE wrigi,ttsoft® At� —I =om­ Right-Sute®UNversa1202424.0.01RSU14048 FOR ALL INSPECTIONS ACCP. ...\Home0ocunents\WrightsoftHVAC\971 Gregory.rup Calc=MJ8 From Door faces:W Page 12 of 16 N Sheet 1 Provide 4"outside air duct for ventilation 213cm 124 0M 213 cfrn 164 Om ed3 124c 91, 473c 7" 8, great 257c Ernaster 12" 9,, 5,-bath 46 cfm 1 flcknbe 146 c rrbath Laundry 2cm ed2 71 146 cfi 14 cfm garage CITY APPROVED PLANS R—cwed for Code Compliance PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Job#: 971 Gregory Precision Heating Scale: 1 : 133 Performed by Precision Heating for: Page 1 Eagle Ridge Right-Suite®Universal 2024 24.0.01 RSU14048 2025-Jan-03 09:06:22 \Wrigh oft AC 71 Gregoryrup Duct System S Job: 971 Gregory +� wrightsoft uc emummary Date: 01/02/25 entire By: Precision Heating Precision Heating Project • • For: Eagle Ridge Heating Cooling External static pressure 0.70 in H2O 0.70 in H2O Pressure losses 0.31 in H2O 0.31 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.240/0.150 in H2O 0.240/0.150 in H2O Lowest friction rate 0.067 in/100ft 0.067 in/100ft Actual airflow 1080 cfm 1080 cfm Total effective length(TEL) 583 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln(ft) Trunk Landry h 1846 71 28 0.165 5.0 Ox 0 MtFx 10.3 135.0 st1 bathl h 1190 46 21 0.067 5.0 Ox 0 MtFx 53.2 305.0 st2 bedl c 2849 112 146 0.080 8.0 Ox 0 MtFx 54.0 245.0 st2 bed2 c 2908 130 149 0.072 8.0 Ox 0 MtFx 66.0 265.0 st2 bed3 h 3233 124 108 0.069 7.0 Ox 0 MtFx 64.0 285.0 st2 great c 4161 170 213 0.097 8.0 Ox 0 MtFx 41.0 205.0 st2 great-A c 4161 170 213 0.086 9.0 Ox 0 MtFx 54.0 225.0 st2 master c 3205 153 164 0.112 8.0 Ox 0 MtFx 28.1 185.0 st2 mbath h 1874 72 29 0.142 5.0 Ox 0 MtFx 14.0 155.0 st1 vic h 832 32 11 0.200 4.0 Ox 0 MtFx 5.0 115.0 st1 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 PeakAVF 905 1012 0.067 725 16.0 0 x 0 MetlFlx st1 st1 PeakAVF 1080 1080 0.067 773 16.0 0 x 0 MetlFlx CITY APPROVED PLANS Boldatalic values have been manually overridden Reviewed for Code Compliance PLANS MUST BE ON JOB SITE wrilghtsoft® FOR ALL INSPECTIONS �.�,•x••.•,�mw, Right-Sute®Urrversal202424.0.01 RSU14048 \Home\Doarnents\WrightsoftHVAC\971 Gregory.np talc=MJ8 Front Door faces:W Page 14 of 16 TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cftn) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb3 Ox 0 130 149 199.1 0.076 426 8.0 Ox 0 MtFx rt2 rb4 Ox 0 124 108 225.0 0.067 356 8.0 Ox 0 MtFx rt2 rb2 Ox 0 112 146 164.1 0.092 545 7.0 Ox 0 MtFx rt2 rb1 Ox 0 457 473 142.2 0.106 603 12.0 Ox 0 MtFx rt2 rb5 Ox 0 257 204 113.1 0.133 581 9.0 Ox 0 MtFx r2 TableReturn Trunk Detail Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rt2 PeakAVF 1080 1080 0.067 611 18.0 0 x 0 MetlFlx rt1 rt1 PeakAVF 1080 1080 0.067 611 18.0 0 x 0 MetlFlx CITY APPROVED PLANS Reviewed for Code Compliance PLANS MUST BE ON JOB SITE ® FOR ALL INSPECTIONS wrightsoft �� ••�.�,•x••.•,�mw, RighRSute®UNversa1202424.0.01RSU14048 y \HomeVocunents\WrightsoftHVACt971 Gregory.np Calc=MJ8 Front Door faces:W Page 15 of 16 Job: 971 Gregory +� wrightsoft, Static Pressure and Friction Rate Date: 01/02/25 entire By: Precision Heating Precision Heating Project Information For: Eagle Ridge AvailablePressure Heating Cooling (in H2O) (in H2O) External static pressure 0.70 0.70 Pressure losses Coil 0.12 0.12 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0.03 0.03 Other device 0 0 Available static pressure 0.39 0.39 Total • Supply Return (tt) (tt) Measured length of run-out 2 12 Measured length of trunk 51 43 Equivalent length of fittings 305 170 Total length 358 225 Total effective length 583 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.067 OK 0.067 OK Return Ducts 0.067 OK 0.067 OK Fitting Equivalent LengthDetails Supply 4AD=60, 11 M=20, 11 M=20, 11 M=20, 11 M=20, 11 M=20, 11 M=20, 11 M=20, 111=10, 11 M=20, 11 M=20, 11 M=20, USR1=35:Total EL=305 Return 6M=20, 11 M=20, 11 M=20, 11 M=20, 11 M=20, 11 M=20, 111=10,5D=40:Total EL=170 CITY APPROVED PLANS Reviewed for Code Compliance wrightsoft® PLANS MUST BE ON JOB SITE e, ComPa, Right-Sute®UNversa1202424.0.01 RSU14048 FOR ALL INSPECTIONS ACCP. ...\Home0ocunents\WrightsoftHVAC\971 Gregory.rup Calc=MJ8 From Door faces:W Page 16 of 16