Loading...
HomeMy WebLinkAbout19-0477 2152 Village Park Ave CO #1 City Approved Plans o�z GENERAL FRAMING NOTES: r.7 1.EXTERIOR WALLS 2x6,INTERIOR WALLS 2x4 UNLESS NOTED.DOUBLE TOP PLATE AND SINGLE 4 BOTTOM PLATE. A5.1 2.FIELD VERIFY ALL DIMENSIONS. 0O 5'-7" 10,-5" 10'-4" 10'-4" 10'-4" 10'-4" 9'-0" 4'-7' 7'-3" 5'-6" 6'-4" 3.VERIFY ALL WINDOW AND DOOR HEADER HEIGHTS WITH GENERAL CONTRACTOR. A A T 4.WINDOW AND DOOR HEADERS TO BE 4x8 OF w/ 5•-o^x5'-o" 0^x5•-0^ 5'-o"x5'-0" F-0"x5•- 5'-o"x5'-0" 5'-0"x5,-0" 5'-0"x5' 0^ , 5•-o^x5'-o" 5'-0"x5'-0" 2X6 TOP AND BOTTOM PLATES UNDER 5'-0"SPAN. 3'-0"AFF .Op Op 3'-0"AFF 3'-O"AFF T-0'FF 3'-p"AFF T.0'AFF 3'-0AF 3'-0AFF T-10"AFF USE 400 w/2x6 TOP AN D BOTTOM PLATE AS a HEADERS UP TO 7'-0"SPAN w/DOUBLE CRIPPLES. ALL LARGER SPAN HEADERS WILL BE CALLED OUT ON PLAN. n1 or �V FUTURE SU ERY r FUTURE O@ERATORY r OPE ATO OPERATO OPERATO FUT RE OPERATORY r OFFICE n a 5.SHEAR PANELS ARE TO BE 7/16"OSB SHEATHING U 10''4" 101a 4" 10'04" 10'-4" m 10'- r -"e w/MIN.6d NAILS OR MIN 13/4"GAUGE STAPLES I2 4" -8" 5'-0" 11'-8" U I� p FOUNDATION FIELD NAILING AND 3"PERIMETER NAILING.SEE 9 P 9" P 9P OFFI E/ FOUNDATION PLAN FOR STHD14 STRAP LOCATIONS. LOU B6.ROOF SYSTEM TO BE PRE ENGINEERED B MANUFACTURED WOOD TRUSS S.SEE TRUSS MANUFACTURER LAYOUTS AND SPECIFICATIONS r io g r B w FOR INSTALLATION. m B B 3 °" 6 7.USE TEMPERED GLAZING INDOORS,SLIDING _5 all a_ __ __ _ PATIO DOORS.STORM DOORS.SHOWER&BATH 3nli`al UfDIF D EXTINBG�UI SHER, o' '\ ENCLOSURES,WINDOWS WHERE NEAREST 3' N EXPOSED EDGE OF THE GLAZING IS WITHIN 48"OF A ARCHITECT STAMP REsTROOM` B B VERTICAL EDGE OF AN ACTIVE DOOR AND FIXED WALL MOU TED w/ 0 NP' NP' NP' TOP<5'AFF B B A• PANELS GREATER THAN 9 SO FT WITH THE LOWEST LICENSED 10'CEILING 10o B EDGE LESS THAN 18"ABOVE FLOOR. RCHITECT u' I _� I I FUTU TORY IIi DESK 1 - AR-985249 3'-o"x7'•0" STERIL ZATION B �n ^ADA GRAB BARS REMOVE 9 DRYWALL NOTES: 14'-0" 6'-0" m 8'-0" 5'-31/2" 0 9'-0" D 30'-9• 1.5/8"SHEETROCK INSTALLED ON ALL CEILINGS. Via.. v g ARCHED LAB m 6,a STORAGE NI AGING OPENING 2.112"SHEETROCK INSTALLED ON ALL WALLS,UNLESS B 11 B o NOTED. � � II A Ir------ - r Zi'-o" T•o'• 0 3.ANY FIREWALLS WILL BE NOTED ON PLANS WITH �za B 3'-o"zT-o" SPECIFICATIONS FOR RATINGS. SICA PE 5'-31/2' 10'-10" 14'-0" 3'-2" 5'-31/2' iv '-0" LL _____ _ _ 4.SHEET PERIMETERS SHALL BE NAILED AND FIELD ATE OF IDAHO FU�II TORV Q OFFICE j JANITOR SCREWED PER CODE REQUIREMENTS. IL MANAGER K 5.STANDARD FINISHING PRACTICES OF TAPING, e a _ W ME�IS ^ COATING AND SANDING. C_= so CONSULTo ___ ___, LL .� e� -,�8 r & z-W^x7•-o'• QJ 6.CORNER BEAD ON ALL CORNERS UNLESS DIRECTED T14' Ir 3 0^ I BYGENERAL CONTRACTOR. vi -0 h-0T-8 7'-11 3/4" " TENANT SPACE 7.FINISH OF DRYWALL SHALL BE'HAND TEXTURED'w/ 1450 SQ FT o M HAND DOBBED CEILINGS AS STANDARD,UNLESS ------ 7-1. v DIRECTED BY GENERAL CONTRACTOR.NOTE:BULK OF J _____"_ _ 10'CEILING - - MAY ' S'-o^x7-0'• 3'•o^x 7'.0.1 'i ��� _ SMOOTH TEXTURE. STANDARD'WITH SPECIAL AREAS OF SMOOTH TEXTURE. FOOTING FOR �� D B � B RECEPTION - �zo FUTURE N¢ g 3 Ir - _ 8.ALL STEPPED CEILINGS ARE NOT TO RECEIVE ANY PERGOLA c7 L' MECHANICAL 28'-31/2" 11 IL, A6.2 B,' 3'-o xa•-o CORNER BEAD UNLESS DIRECTED BY GENERAL w I W h a I _ THE B I In CONTRACTOR.ANY CORNER BEAD INSTALLED IN n 3'-0" a� -. -- __________ ___ ____ __ __—' in RESPONTHESE SIBILITY IN ERROR SUB CON RA � � 0 w I � RESPONSIBILITY OF THE SUB CONTRACTOR TO SIR ME v - TINGNG o '-________ _ v SEE ORIGINAL PLANS REMOVE AND DISPOSE OF THE MATERIALS AT THEIR ---- - EXPENSE. ' P<5'AFF. __ __ ____ram_____ ___ ELL iv n9.PROVIDE WATERBOARD AT ALL TUB AND SHOWER O«, L MOUNTED ARCHED OPENI G---- ------- --- ALL OT F R HER_ 3'-°"x 3'PB,/4" ''-„3/4" 6'-4,/2 9'-1" °'-„/2 6'-7,/2" °" _ REDLINES THAT STILL LOCATIONS. QQ . it g HQ p F ARCHED OPVf ING APPLY 10.DRYWALL CONTRACTOR TO PRIME FINISHED o m I I II TAPED,COATED,AND SANDED AREAS PRIOR TO ------ �,I STAFF o QI IPAD SNACI gOUNTER 5 11 DRRYWALL CONTRACTOR TO REMOVE ALL DRYWALL J p, b STATION v. FOOTING FOR = r 34"MAX u- gRRI L --J _-------J `---------J L---- SCRAP,DEBRIS,AND LEFT OVER MATERIALS FROM A 4' 71/16" 2' 0" io I Co FUTURE m W :13'-8"HEIGHT R 2' n __� r__________r r�________� r_______ � r_____ 2'-51/2" ,oia JOB. LL- ',; � COUNTER � PERGOLA -xllg 111/4" 18'-41/2" 31/2" 3'-81/2" 10'- 13'-4i/z^ _ ALL EXIT DOORS OTHER THAN C SEWORK o _ MAIN EXIT DOOR TO HAVE 12.HANG ALL GARAGE CEILINGS AND WALLS WITH 5/8" Z e< K. C BINET a - PUSH-PAD,PANIC,OR LEVER 51/4" ___ __ HARDWARE THAT UNLOCKS IN aI M 13.TAPE,COAT,SAND AND LIGHT ORANGE PEEL o e n oLL BREAK I'I 1z'cEluNc L-------- J L---------J ------ -- OLL ASINGLEMOTIONWITHOUT e a BENCH/ 24\o. J L----------J r-------- - r---------� ----- KEY. TEXTURE ON ALL GARAGE WALLS UNLESS NOTED CEI ING o WALL � BREAK ROOM � _ _________ - tO MOUNTED ----- 1 ri —."a OTHERWISE ON PLAN OR DIRECTED BY GENERAL Z TV - A CONTRACTOR. LOCKERS B 1 41-d i i WAITING I I D xe m KIDS i I I A m n L J m a, CORNER o I A ; _ WALL TYPES ONY WALLS -----"----- - rn o ^ m oa o , iv M m 1v '-6^xs•-°^� z• 2'-0"I5'-0" T-6"x5'-0" 2'-6"x5'-o'• EXTERIOR SEE:ELEVATIONS FOR FINISH COLORS LL A 3'-0"AFF S'-0"AFF 3'-0"AFF 3'-0"AFF 9'-0"AFF _ 2'-0"x5'-0" 2'.0'x5'-0' 2'-6'x5'-0" 6'-0"x5'-0" 2'-6"x5'-0 2'-6%T-0" 8•-0"z5'-0" T-6"x5'-0^ ' Z w 3'-0"AFF 3'-0"AFF 3'-0"AFF 3'-0"AFF 3'-0"AFF 12'C LIN T 0'AFF S'-O^AFF 3'-0'AFF A TYP.EXTERIOR WALL: Q 2•-o^x5'-o" e O FIBER CEMENT SIDING(REFER TO c3'-0^AFF 2 X 6 WOOD STUDS ELEVATIONS AND SECTIONS)OVER BLDG. ;I WRAP&EXTERIOR SHEATHING E H AGING HT ATTACHED TO 2X6 WD.STUDS @ 16"O.C. W/(1)LAYER 9/8"GYP.BD.AT EXPOSED INTERIOR FACES.PROVIDE MIN.R-21 m 2 BATT CAVITY INSUL. L 0 ET 6AR1511NCH INTERIOR ON ORIGINAL DRAWING d 0 ro 1'-71/2" 19'-10" 1'-71/2"2'-0" 13'-7" 2'-0" 8'-0" 2'- 14'-10" 9—1 lu TYPICAL �Z6- -2" 4'-9" 4'-9" 3'- 5'-0" 5'-0" 4'-9" 4'-9" 3'-2" 4'-0" 4'-0" 2'-41/2"2'-6" 2'-6" 2'-6" 2'-6"2'-41/2' 4'-0" 4'-0" O WOOD STUDS ATR6"O.C.WITH 5/8" IF NOT 1INCHoN °' GYPSUM BOARD EACH SIDE. THIS SHEET,ADJusT 2 X 4 WOOD STUDS scRDIN1-0" 5'-2" 15-10" 1 -0" 15-10" 8-0" 1 -9" 8-0" PROVIDE SOUND BATT INSULATION AG60RDwGLv ATALL NEW WALLS.INSTALL WALL 0 4 TO STRUCTURE ABOVE.TAPE, ORANGE PEEL TEXTURE&PAINT. 1-MAIN FLOOR PLAN A51 O REVISIONS PLUMBING WALL: WOOD STUDS AT 16"O.C.WITH NO. REMARKS 3 PROVIDE SIGN ABOVE 2 X 6 WOOD STUDS 5/8"GYPSUM BOARD EACH SIDE. TAPE,ORANGE PEEL TEXTURE& DOOR,"THIS DOOR TO PAINT. o REMAIN UNLOCKED 2 WHEN BUILDING IS O 9 OCCUPIED" O 1-HR FIRE WALL: N 2X6 WOOD STUDS AT 16"O.C. 2 X 6 WOOD STUDS WITH 5/8"TYPE"X"GYPSUM CHECKED r BOARD EACH SIDE (ILL DES U 305) DATE 02.06.2017 CITY APPROVED PLANS DRAWN JESSICA JOB NO. 001 Reviewed for Code Compliance SHEET PLANS MUST BE ON JOB SITE �� NUMBER FOR ALL INSPECTIONS A2. 1 Page 1 of 1