Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-4829 1996 Kodiak St - City Approved Plans
Permit # IMon Load Short Form 20-4829 Job: 1 -2 Grandview Estates Date: 11-24-20 Entire House iv By: Lance Limbocker EfflZ Icon Air 12/9/20 Plan: Sundance 2710(OH) Phone:208-475-0701 Email:HvacDesignTeam@cbhhomes.com Project Information For: 16-2 Grandview Estates, CBH Homes xxxx Kodiak St., Twin Falls, ID Design Information Htg Clg Infiltration Outside db (°F) 2 95 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD (°F) 68 20 Fireplaces 0 Daily range - H Inside humidity(%) 50 50 Moisture difference(gr/lb) 58 -36 HEATING EQUIPMENT COOLING EQUIPMENT Make Lennox Make Lennox Trade LENNOX Trade LENNOX Model ML180UH09OP48B Cond 13ACXN042-230- AHRI ref 4208209 Coil CH35-48B AHRI ref 7623325 Efficiency 80 AFUE Efficiency 11.0 EER, 13 SEER Heating input 88000 Btuh Sensible cooling 35275 Btuh Heating output 71000 Btuh Latent cooling 6225 Btuh Temperature rise 55 °F Total cooling 41500 Btuh Actual air flow 1355 cfm Actual air flow 1400 cfm Air flow factor 0.032 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0.80 in H2O Static pressure 0.80 in H2O Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Bed 5 161 2668 1419 85 73 Kit/Din 964 14594 9532 466 487 Half Bath 34 0 0 0 0 Master Closet 115 2693 645 86 33 Bed 4 191 3577 2078 114 106 Master Bed 284 3517 3480 112 178 Master Bath 133 1602 880 51 45 Bed 2 221 3897 2682 124 137 Loft 280 3862 3389 123 173 Bed 3 163 4524 2837 144 145 Hall Bath 62 1510 452 48 23 WIC 3 44 0 0 0 0 Stair 1 47 0 0 0 0 Stair 2 54 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8 CITY APPROVED PLANS wrightsoft Reviewed for Code Compliance Right-SuiteO Universal 2019 19.0.20 RSU20077 ...esktop\MJ's\GRANDVIEWESTATESB2LOT16Sundance.rup CaIftgr6 Dtrfio f1 /1 PLANS MUST BE ON JOB SITE ri �} FOR ALL INSPECTIONS Entire House d 2750 42444 27395 1355 1400 Other equip loads 4818 1417 Equip. @ 1.00 RSM 28812 Latent cooling 0 TOTALS 1 2750 1 47263 1 28812 1 1355 1 1400 Calculations approved by ACCA to meet all requirements of Manual J 8 CITY APPROVED PLANS wrightsoft Reviewed for Code Compliance Right-SuiteO Universal 2019 19.0.20 RSU20077 ...esktop\MJ's\GRANDVIEWESTATESB2LOT16Sundance.rup Calftgre D6�rfof`"14 PLANS MUST BE ON JOB SITE G (( FOR ALL INSPECTIONS Project Summary Job: 16-2 Grandview Estates Summary Date: 11-24-20 Entire House By: Lance Limbocker L9IR Icon Air Plan: Sundance 2710(OH) Phone:208-475-0701 Email:HvacDesignTeam@cbhhomes.com Project Information For: 16-2 Grandview Estates, CBH Homes xxxx Kodiak St., Twin Falls, ID Notes: Furnace in attic Design Information Weather: Twin Falls AP, ID, US Winter Design Conditions Summer Design Conditions Outside db 2 °F Outside db 95 °F Inside db 70 °F Inside db 75 °F Design TD 68 °F Design TD 20 °F Daily range H Relative humidity 50 % Moisture difference -36 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 6„ MIN. 33105 Btuh Structure 20418 Btuh Ducts 9340 Btuh Ducts 6978 Btuh Central ve t(75 cfm) O.A. 4818 Btuh Central vent(75 cfm) 1417 Btuh Outside DUCT Outside air Humidification 0 Btuh Blower 0 Btuh Piping Btuh Equipment load 47263 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28812 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure -431 Btuh Ducts -518 Btuh Central vent(75 cfm) -1589 Btuh Heating Outside air Area(ft2) 2750 2750 Equipment latent load 0 Btuh Volume (ft3) 22004 Air changes/hour 0.41 0.21 Equipment Total Load (Sen+Lat) 28812 tuh Equiv.AVF (cfm) 150 77 Req.total capacity at 0.85 SHR ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade LENNOX Trade LENNOX Model ML180UH09OP48B Cond 13ACXN042-230- AHRI ref 4208209 Coil CH35-48B AHRI ref 7623325 Efficiency 80 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh Sensible cooling 35275 Btuh Heating output 71000 Btuh Latent cooling Btuh Temperature rise °F Total cooling 41500 tuh Actual air flow 1355 cfm Actual air flow cfm Air flow factor 0.032 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0.80 in H2O Static pressure 0.80 in H2O Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8 CITY APPROVED PLANS Reviewed for Code Compliance wrigf�tsof t - - Right-suite®Universal.role alP Rsu2oo77� a f4 A PLANS MUST BE ON JOB SITE AMN ...esktop\MJ's\GRANDVIEWESTATES62LOT16Sundance.rup Cal f13�('� D,Qirf c °°1 iF `.`�J FOR ALL INSPECTIONS N Level 2 1 2 x 4 12x4 12x4 114 cfm 89 cfm 89 cfm Bed 4 8" Master Bed 8" Master Closet 8' g 14 x 14 337 cfm 4 x 12 4 x 10 86 cfm 48 cfm 14 x 10" 8 6 F ❑ 14„ 14" p Hall Bath 4 x 101 6" Master Bath 51 cfi HVAC Chase WIC 3 18" 8" Stair 2 20 20 8 Ili 14 ❑ 8 14 x 8 106 cfm 6"Sidewall 8„ 8" Fresh Air Bcd Bed 3 L 12x4 o$ 137 cfm 12x4 8 145 cfm 12 x 4 4 x 1 Sundance 2710 CITY APPROVED PLANS Reviewed for Code Compliance PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Job#: 16-2 Grandview Estates Icon Air Scale: 1 : 83 Performed by Lance Limbocker for: Page 1 16-2 Grandview Estates RightSuite®Universal 2019 xxxx Kodiak St. 19.0.20 RSU20077 Twin Falls,ID $�o 0 0701 2020-Nov-24 11:51:54 Pagle.A0Atam is hhomes.com ...NDVIEWESTATESB2LOT16Sundanc N Level 1 4x12 81 cfm 12x4 85 cfm 12x4 00 81 cfm 00 8 8" 8" Kit/Din Bed 5 14x8 12x4 81 cfm ® El Half Bath x12 �14x8 1 cfm 8" Stair 1 I8' 4x12 3rd Garage Bay 12x4 81 cfm Garage Furnace in attic Sundance 2710 CITY APPROVED PLANS Reviewed for Code Compliance PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Job#: 16-2 Grandview Estates Icon Air Scale: 1 : 83 Performed by Lance Limbocker for: Page 2 16-2 Grandview Estates RightSuite®Universal 2019 xxxx Kodiak St. 19.0.20 RSU20077 Twin Falls,ID o 0 0701 2020-Nov-24 11:51:54 PagiecA04:f am c hhomes.com ...NDVIEWESTATESB2LOT16Sundan =Orl Duct System Summary Job: 1 -2 Grandview Estates Date: 11-24-20 Entire House By: Lance Limbocker alR-- Icon Air Plan: Sundance 2710(OH) Phone:208-475-0701 Email:HvacDesignTeam@cbhhomes.com Project Information For: 16-2 Grandview Estates, CBH Homes xxxx Kodiak St., Twin Falls, ID Heating Cooling External static pressure 0.80 in H2O 0.80 in H2O Pressure losses 0.61 in H2O 0.61 in H2O Available static pressure 0.19 in H2O 0.19 in H2O Supply/return available pressure 0.121 /0.069 in H2O 0.121 /0.069 in H2O Lowest friction rate 0.066 in/100ft 0.066 in/100ft Actual air flow 1355 cfm 1400 cfm Total effective length (TEL) 288 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bed 2 c 2682 124 137 0.107 8.0 Ox 0 VIFx 27.6 85.0 st2 Bed 3 c 2837 144 145 0.101 8.0 Ox 0 VIFx 29.6 90.0 SO Bed 4 h 3577 114 106 0.100 8.0 Ox 0 VIFx 30.6 90.0 SO Bed 5 h 2668 85 73 0.086 8.0 Ox 0 VIFx 40.7 100.0 Srs7 Hall Bath h 1510 48 23 0.105 6.0 Ox 0 VIFx 20.1 95.0 SO Kit/Din c 1589 78 81 0.086 8.0 Ox 0 VIFx 45.4 95.0 Srs4 Kit/Dln-A c 1589 78 81 0.093 8.0 Ox 0 VIFx 29.4 100.0 srs3 Kit/Dln-B c 1589 78 81 0.084 8.0 Ox 0 VIFx 39.5 105.0 Srs1 Kit/Dln-C c 1589 78 81 0.090 8.0 Ox 0 VIFx 35.2 100.0 srs5 Kit/Dln-D c 1589 78 81 0.066 8.0 Ox 0 VIFx 48.5 135.0 srs6 Kit/Dln-E c 1589 78 81 0.094 8.0 Ox 0 VIFx 28.2 100.0 srs2 Loft c 1695 62 87 0.097 8.0 Ox 0 VIFx 30.1 95.0 st1 Loft-A c 1695 62 87 0.100 8.0 Ox 0 VIFx 31.1 90.0 st1 Master Bath h 1602 51 45 0.123 6.0 Ox 0 VIFx 13.2 85.0 st2 Master Bed c 1740 56 89 0.100 8.0 Ox 0 VIFx 30.5 90.0 st1 Master Bed-A c 1740 56 89 0.100 8.0 Ox 0 VIFx 30.8 90.0 st2 Master Closet h 2693 86 33 0.112 8.0 Ox 0 VIFx 18.4 90.0 st2 * wrightsoR' CITY APPROVED PLANS t e. _, Right-SuiteO Universal201919.0.20 RSU20077 Reviewed for Code Compliance ...esktop\MJ's\GRANDVIEWESTATESB2LOT16Sundance.rup Calc=MJ8 Front Door faces: W Page 6 of 14 PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk srs6 Peak AVF 78 81 0.066 233 8.0 0 x 0 ShtMetl st9 st5 Peak AVF 78 81 0.086 233 8.0 0 x 0 VinlFlx st2 st3 Peak AVF 78 81 0.094 233 8.0 0 x 0 VinlFlx st1 st6 Peak AVF 78 81 0.093 233 8.0 0 x 0 VinlFlx st2 st7 Peak AVF 78 81 0.090 233 8.0 0 x 0 VinlFlx st2 st8 Peak AVF 78 81 0.084 233 8.0 0 x 0 VinlFlx st2 st4 Peak AVF 85 73 0.086 244 8.0 0 x 0 VinlFlx st1 st1 Peak AVF 649 690 0.086 646 14.0 0 x 0 VinlFlx st9 Peak AVF 78 81 0.066 233 8.0 0 x 0 VinlFlx st2 srs5 Peak AVF 78 81 0.090 233 8.0 0 x 0 ShtMetl st7 srs2 Peak AVF 78 81 0.094 233 8.0 0 x 0 ShtMetl st3 srs7 Peak AVF 85 73 0.086 244 8.0 0 x 0 ShtMetl st4 srs4 Peak AVF 78 81 0.086 233 8.0 0 x 0 ShtMetl st5 srs1 Peak AVF 78 81 0.084 233 8.0 0 x 0 ShtMetl st8 srs3 Peak AVF 78 81 0.093 233 8.0 0 x 0 ShtMetl st6 st2 Peak AVF 706 710 0.066 664 14.0 0 x 0 VinlFlx TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox 0 1028 1063 98.4 0.070 602 18.0 Ox 0 VIFx rb3 Ox 0 327 337 104.6 0.066 618 10.0 Ox 0 VIFx wrightsoR CITY APPROVED PLANS .-.»e...-,.., Rig ht-Suite®Universal 201919.0.20 RSU20077 Reviewed for Code Compliance ...esktop\MJ's\GRANDVIEWESTATESB2LOT16Sundance.rup Calc=MJ8 Front Door faces: W Page 7 of 14 PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS TOTAL: 4725 MONT/ FLANV; 2400 CONC; 580 p�Ap; 2525 DO NOT DRAIN STORMWATER ONTO ADJACENT PROPERTIES. LANDOWNERS ARE RESPONSIBLE FOR C�\� B H HOME 5 20 1 -01 1 �STORMWATER RUNOFF FROM THEIR PROPERTY. — z CITY CODE 10-11-8(A)BUILDING SITES SHALL USE , BEST MANAGEMENT PRACTICES(BMP'S)TO RETAIN 0 AS MUCH STORM WATER AS POSSIBLE ON THE PROPERTY. SEE IDAHO CATALOG OF STORM WATER rv� POMP, I�° �O I �L,�I I W ( 100,001 ) BEST MANAGEMENT PRACTICES. N Q �1 ZONE: R-2 SEWER #: 20010 fOP OF AC PAP @ WATER #: 9722 PO TOM 0r M VM N1' \\' � z IRC SECTION R401.3 SURFACE DRAINAGE SHALL BE DIVERTED AC n� SL TO A STORM SEWER CONVEYANCE OR V/ OTHER APPROVED POINT OF COLLECTION kf� o2s THAT DOES NOT CREATE A HAZARD. ALL PARKING AND 3i611 X 31611 C>6 LOTS SHALL BE GRADED TO DRAIN WATER CONC AWAY FROM FOUNDATION WALLS. >G >G � CC � MANUVERING TO BE THE GRADE SHALL FALL A MINIMUM OF 6 C SOLID SURFACED 1 1 � INCHES WITHIN THE FIRST 10 FEET. LOT 1 �0 z LINES LESS THAN 10'FROM FOUNDATION TO BE 2%SLOPE MINIMUM FROM FOUNDATION. O /� z � �nz � 0 251 -1 11 M C NC, O � O v v �O� z-< � O bl?IV WAY GAI?A6� O 1996 ° W/ �X J01 r5 coNc 7-7 � O � �� 0 � A fully visible _ _ �� o � temporary address �_ SE BEST MANAGEMENT PRACTICE O z� sign shall be posted J TO RATER ONAIN OPROPEORT TO O on all construction 0 39% IMPERVIOUS 0 z sites and remain in o '1-011 WingCONC TOP OF W10 0 WALKWAY FOUNDATION TO 1� X 10 O place until the W/M JOINT5 TO ABOVE GUTTER >O CONC 6 O ermanent address oPIC IRC SECTIONR317.1 WOOD SIDING,SHEATHING,AND Q HOUSE IS TIC f EMI X 7 31I WALL FRAMING ON THE EXTERIOR CSC Z � is in place. STRING LINES TO BECONC OF A BUILDING TO BE 6"MIN. FROM EZ X O PROVIDED OVER EARTH&2"FROM CONCRETE OR BE 0 Z PROPERTY PINS AT TIME PRESERVATIVE TREATED. OF INSPECTION Z 77 z L P\2 ZONN6 � o o � � Ez o N (59, 50' �11 W 000,001 ) o vz FIT-0 II 1 II 2O 'O SCALD; 3/ 16" CITY APPROVED PLANS - I ' �011 �AS�M�N1' S���ACK & � �� v�� �AS�M�Nr Reviewed for Code Compliance 201 -011 6AL PLANS MUST BE ON JOB SITE 5�113ACK FOR ALL INSPECTIONS 'j LOT 16 BLOCK 2 FRONT 50b & 5rr\INUP\5 6MNbVUW �5fM5 #I FOUHPAIOil O MN VOVF C U PI3 LANb5CAP� DOCK TWIN FAl,L5, IPMO C D '5" CAl MF TF\��5 Page 8 of 14 2 X 6 PkE55Ke 1EEATEV VAPOPPAftUNIT ALI,PLATAr CB�■■� HOMES WIE NP6 OF FOUNVA9GN I I I I LEGEND aN uNrEz slLl PLATE II II — — I I I I $ 5W1TCN ® SMOKE — — 6 MiL vrrcE PAP lEP u aoSEr II •1III=11I PEJk00M N0 4 MASrEk PEnk00M I I I I � UGNT �Q CAN UGNi 110 PLUG ©1KPM05fAf (62201 F❑ 50" — — — 11 ®cAkPON MONOXIDE MT. p r3AppiFp PFTA�l 30" MIN. CLEAR F VApo ® coMPo sn a CM nEr. 5CAE'12 CRAWL SPACE \` 12"MIN.to 36"MAX OVERDIG 48-_01I FROM EDGE OF FOOTING ili/ II NOTE; Mid HOME5 kF5FI THF PICK TO MOnIFY NVPL 3'2" 4'0" ANJ ELECIP.ICAL WITHOUT'NOTICE. ELECTICAL OUTLET' Le CA6-E p0 AON5 oN PAN WILL VAKY i THE ACTUAL LOCA110N IN THE HOME.OUILET LOCATION WILL PE 24"X 24"X 9"EFP AJJU5TP TO MEET COPE 51'AQNG rW_IIkEMEN1`5----- X 3'MAX FROM -- -- - -- -- NERS O --///-/----- _® ONN A __= 6AiN X 6 Ek5 SIGNATUkkt o ----6�R 6 FL FLIP -- - Ll _ kA°0�0�OEP o 13MV5 51GNAT'U PEEP .. .. . .. ; - ----Ae xnwn ------- ----- �••• L c2)-4 M6 E Y J� ■ II i ■ ' _� 6"X 24"CONC FNJ .... ..... .... .... .....■ : S Hnl -' PRESCRIPTIVE METHED PAV 7 I I I1 � wA-L(rYP) 1 II 4 PON WALL' /sw LE TOP PIArE, I I ® 8"X 16"CONC FTG ; G '� EE EM MINI 'M ® Curate U- Wood rn) 5 J5@ 4"0/CINLIN W/J ill",t 50 MINT PTMJ I5T Zone Factor Wall Ceiling Floor I ■ 1 5 .35 Min R-21 R-38 R-30 L ■ __ ____ -- -- -- -- :F 1 - --- ® r1-J -- -- -- -- ---- -_ /C Ol I N 11 4' 2" 011 8' 211 0' 8' 211 ECnk00M NO 2 N 2X4 P Ai V I&IL W 200 E TOE CAPLE PLAT'E�SfUJS 16"0 CS IJ — �—— I O PEJk00M No.3 LOFT : P,OCK NG TO IIPFP P PNEFN 1015T5 ' FA110 L-- -- ' -� -- -- _ -- -- -- ■ J �I F� _1--/ \\ POfTOMOP FNJVENr 6CPAG _J2xi H -- __-- -- -- -- 2xioH -- -- -- ' = TO OF PAn �"x3 6,1 J F wiy r wi n -I- :' N C�' 8' 2ii 10ii 4'211 0ii 4' 2ii 0" 2'Y2' 6' 0 I I 1 N3 i q0 r- PNONEI :.. . Q, L_ 5�CONP FLOOp BEN CABLE BOO i l 1 n O -------- r--_N-1 .. N1 .. ..} o L 1 � KITCHEN I I I ro 1 1 _ 1 1 � I I � � N�I 1 1 � N ■ � 1 Smoke Detector location: 10 L Smoke alarms and smoke detectors shall not be 91N1N6kOOM _ -- installed within 36"horizontal path from the tip ofo"x3o"xe° � 1 0 o" 2'-1" 0 4' 2' — 4 �1 I CONCRES as WO the blades of ceiling-suspended fan. - 1 H05F616 18"OFF FILE i/ 51 GARAGE PAY JA --- CONC r J Smoke alarms shall be at least 3'away from bathroom _____ 11 �_= I I - 1 1 � 1 1 doorway,unless this would prevent placement of a 1 HosE P1P ■ smoke alarm required by NFPA 72 _ _ ___ ---- — . ■ N 9"CONCkET SLAP OWF .... .... .. . . .. i loll OFF FLIP 4"COMP 6MVEL(Tyr) ® --- ---- NT5 WAO z s n6 /2 PA H EX ANSION JO Smoke alarms and smoke detectors shall not be installed u Ll v Mun kMl -- F II a within ka 336"horizontal loath from the supply register of a 6" 'E EEP U1110 r�i );zAmR X,/11 r5 F P PP Y 9 xe' z4"x 24"x a cEEP ASP forced air heating or cooling system and shall be Installed ; — — 30-40ifl WAY CONLHIE FOOTING WL tI- — — ��', (2)#P NEW EACH WAY J outside of the direct airflow from those registers. 11 r--I--- O r- - 8' �''yy" 7Y2" o NW 1 1 1 II � I I - 2�NC�Ak GARAGE Porch o \\\ C PI - ONA/EROaSOY - _ = out 6�roIAr24^c e, o o ow m POOP o Ez wi Mn.paa :Fa :haed=eredoffered ceilings), LE o ----------�detectors shall be wArEk 5OFTFNEk LOOP ® I ISOLATE POSTS FROM--rtion of the ceiling or = J o CONC.SLAB FOR ceilin within 12" — FRosT HEAVE g hest oint. Please Gpo A M P 6POPfA MEANr 29.v ZPF METHOD W PATE AIH Al OVE RS PLANETS PSHALL ACED E INSTALLED SPACING 2)1/2"ANCHOR BOLTS MIN.7-EMBEDMENT W A w sEP 2' R315.1 Carbon monoxide alarms. For new construction,an ` 1" 8'-2" r' 3'-°" I6'- 3'-°" 5'-°" Io'-z" ell approved carbon monoxide alarm shall be installed outside WRY ; 10'-01I 22'-2" P'IoII of each separate sleeping area in the immediate vicinity of — _ -� the bedrooms in dwelling units within which fuel-fired - - -- --- 48'0" appliances are installed and in dwelling units that have 5M GARAGF PAY 15"MIN.WIDTH FOOTING BELOW attached garages.v ALL TWO STORY OR BONUS ROOM FOUNPATION PLAN 2 CAR GARAGE WALLS ABOVE 5CAX:1/4"-I'-0" FOUNJA110N MINFOkCFMENT -� ()-4VAPPLPLEVNGRIZON1H&,YfOPOFFMVWAL CITY APPROVED PLANS - TOP OF .4PAPM EVHG2IZONfALY INPNV.FfG >NFPA(Chapter 29)Smoke alarms shall not be installed in the following p � p �j�i Q i (o.4PAFPLPLEVVEPncA.Y.46--OC Reviewed for Code Compliance locations unless this would prevent placement ofa smoke alarm uc I 05f T VF I50L \ R) FOUNDATION TO (>-4PAPRACWHG2IZONf LYIUPONYWALFf6 NNCHOP Vary H 48"O.C.MPICPU r• 1.Ionization smoke alarms shall not be installed less than 20'horizontally C C C BE MIN. 12"+2% PLANS MUST BE ON JOB SITE r from a permanently installed cooking appliance. 1 1\OM SIB/ V/ For, ABOVE GUTTER y 2.1onization smoke alarms with an alarm silencing switch shall not be �%� 'I� 11�� FOUNPA110N I MIN ABOVE CUVP FOR ALL INSPECTIONS y installed less than 10'horizontally from a permanently installed cooking \05 I N�AVV y appliance. FROM y 3.Photoelectric smoke alarms shall not be installed less than 6'horizontally - r permanently s pp -----------pHoro----------- FL�CTPICAL& MECHANICAL from a ermanentl installed cooking appliance. ------------------------------ kNOT'O r FIP\51"F�001; 5CA-E 1/4"-1'-0" Page 9 of 14 r 5�� MANUFACTUPTP5 5P�C. 5H��T CBH HOMES FOP, FLOOp 1 PU55 LAYOUT CA13iNFf PFfAL kA E,1/411 1'-011 wP;vls -2 G�ANbV �W SSA 5 # Z4"GPEP W 42 30 43JI:, W4230 w`050 e 50''011 a _ _ 101-011 101'I0" 3,.2 1 -011IF 92 PNJG )`6 - fXX363E Uc2"�69h F p;N. A136 23. )IJ16-31JF )36 V36 l'AY5 153YJ sVi V VCG 36 rA1101o'XI0' SILL 4211 cam 38'-011 6°3 e SLCL 6'-011 4'-611 — SINK 40409,CL I W/25, m 40405LCL 40 S,CI, 404°S CL .—I. P,F 0 PE7TKU55INWA I, (2)2xIOHVP5 (22xIOW6 (2)2xlono6 y 5°61Or/PQ0r5LCL y°y° II �w's II <v2a12r�cvs (v2x12nozs I I Do Nor FILL (3)STHPI4 3 I I W/STUPS&LOW � III bF e aG I I N FACE FOP LIGHT PI PPOOM NO,4 N I KITCHEN Ix 3 SWITCHES CPf a, ,vr a'a6 I 111 C,0 au I I z CPT I I — MASTED 6FPPOOM I PINING I Pooh ew s'au 7 3/4"RISE MAX P e'a _ 4''Ityz' 2'-4V22' 3'-0' I 8'_211 — 3/ -1'MIN.RUN 24 I 11"TREADDEPTHNOSING< 5' Sy2' 3'-911 3'-yY" 3''6Y" 3''9y2' S'-3/2' 0 N _ 5 "MIN.HEADROOM 26 FROM NOSING 0 II 9 11 O HANDRAIL 34"-38" a1-Pan ''6y" 24 WALL 24 evm = rznMeoanr II 3'I5V2111 6'-11 3, 9y" erraa y°TU6/ 26 ----- P&5 40 11r ,v WFP — o xas (2)II-9/a"LV, �\ (2)I-9/8"LN.( (2IL2)8l VL(IP) (2)11- 8"LVLUP) KOUCNo NNa _ �e1'�nlc� FOI.I = e F = 29 -- A/C -_-- — �� ° as"PYnNNP - - a 26 j�ePvweele�uEs --- N w 13ATH 9 O exealNlNa g 4 11 ��c�xaox - ro o evp a,aG 2� - �z `J 2a 8 •o - - L�---_JL_____J 4 )"Ca LON � - _ N � 4°0 �z f1n Lf NiN15`.ES nITY 2 g 02" a _ ewa'aaY''�z' & 9/2' I/26A1N _ 7sf 2'�11 a N Iaizr 4'-1Vi1� 3''6Y" wirarwxK — P&_5 6ATN L co 1 w 44"way wA.L evP a'au 2 �a o - Q O g w/WoodCAP S1. f eve e'au 2 1 p )111/8"LVLar) - MUDPM 2'-311 61� -- - x v r w L u z �� N 011, 1 c _ — E�ZeaG �I IsaKzli 4''3/z' w�uwsdLneraLnrcs3 =___ �o III N II � I I 1I MIN.CRAWL SPACE I 5MIF 5�C1 ON N N o ACCESS REQUIRED WITHIN I� _� ,� 11 III N v = —'— SCA,E 1/4' P-o" 8'-p" 4"nlanw L 24 20MIN r NNaw�z 20 FT.OF ALL UNDERFLOORL051 I I� w/W090 CAP PROVIDE IF<60"FROM N �1 I y 311 6 i noaa 3''�" az O'x88i y11 �" CLEAPOOMTS I Iry 5T P302�,E "VISS CTLCF551fNCINIF O5LN UNPEP 24 o O 1 554.83 sf O �JI TAND NG SURFACE 3 9/11 r—1 I CPT BIC16 .� 5TAr5 SHA L 6E rP0 EC EP ON NNCL05NP SIDE INCH(129 MM)GN'SUM 60AP 2 xF V 89 PIYRYIN. INQ I II v � II� 9''Oz11 5''3/2' II'-011 II pE.lq^ aoTas s�2a^o/c I 6EPr00M NO,2 ii APPLIANCES IN ATTIC: Pr &'aG i n 1. Attic access must be large LOFT N x N = MKOOM N0 3 III TYPEXGWT3WALS&CEILING --- Pr a'au cr 81as �.. 2x6 enough to remove equipment. 42"Nlbl I/2 WALL p - P E,sfY.lL'iIPk 66iPM ENn fQllss 3PPGAPAGEI3AY N . EXPAN510N NN y w/WOGVU 2. Must have a 30"X30" service y''6" 5''°" y'-6" oNc a'aa N JOINTS F a'aN (2)2%12Wks N N �24" .............— _ _ _ _ ------------------- equipment. L1E GIPPEDTPU55 — ii 3° y°y°mow/GPID5 platform on service side of II 011 2" 40409L W/GPIPS - 2 CAP GAPAGF 5''9" = 3. Must have light and switch at b"nP o � � Q na+rroroeeLAre ii coNc 8'aG � _ FLAT TOPf?J55 o le'�^^^' - service platform. 11.21" 5W.24'' P.e.sMe rxsweeNo z s @Por'OUT GIPPNPTPU55 4''y" 2 NO S fAPNPr012".KM0` Q ......— — — — — — — — — — — — — — — _ _ _ _ _ _ _ r " DRWO2 0 4. Condensate overflow —(ii2kliiz — — E 40 0 W/GPID5 40 05UW/GPID5 a07°OHPoor o protection to be provide per o (2)2x (2)2Yennr5 narcfo P PLAT 116M ro OP PLAT (2)2X12VWHIP /FLLFps o N section 1411.3.1 of the 2012 o � � FIIF.R OIXwfI�LEl4!Ali of 6M -' I6°9°ON POOP ro nurcn oeuKers eM aw(xe eLev) - - - - - - - - - - - - - - - - - — IRC 4'-11 121-611 T-1011 31,6ii 8,811 31,811 2 II'9/8"LVL NPP 10'-2" a" 5. Trusses to be designed for 38_p1 101-011 22''2" 4 1y1'1011 o" additional dead loads for the weight of the appliances. S�CONP FLoop Fip5f FLoop 2 X 6 FXV10P WA,, 5 ONLY HFAnEPNOE CITY APPROVED PLANS \ • 60TTOM OF NFAPFP AT 6'11 Z' JNLE55 NOTED OTHNki(U.N.0) Reviewed for Code Compliance 2)2X8 HPPS U.N.O. SUNPANCF(LF0CY) • &I,HEADNPSONEDGE PLANS MUST BE ON JOB SITE FLOOk PLAN • ALL HW)NP5 APF 42 POU6 NIP 5CA.E:1/4"-1'-0" Tor of APCHWAYS APE 1211 FPOM TOP FOR ALL INSPECTIONS 2V10 5Q FT FINISH OF 9'FLATE UNLF55 NOTED 01YIFIrl 1224 .2K 5Q FT FIPST FL00? TOP OF ARCHWAYS AW,9"FPOM TOr 1503 W,)5'5Q FT SECONP FLOOD OF 8'PLATE UNLF55 NOTED OTHFPWISF 138 50 FT GAPAGF 93 50 FT COVFPFP rOPCH 20 5O FTCOVFPFP PA110 Page 10 of 14 H KM NF R H HOMES - --- -- �DRIF FDCE CB -- -- — — �FA,CNIA Buildings shall have approved address numbers,or approved building Identification placed p All buildings shall have a permanently posted address,which shall be placed at each driveway 2 ( I A PV f W F 5TAfF 5 entrance and be visible from both directions of travel along the road.Buildings shall have approved \ address numbers,or approved building Identification placed in a position that is plainly legible,visible from the street or frontage road fronting the property and of a contrasting color(IFC 505.1). a �j�Q �i �y/��% Q Address size is based on distance from the street:up to 50 ft.is 4 in.,51 to 100 ft.is 6 in., 101 to 150 CAn'.W I� V IV ACKEf V FT A�� TO50'r1r ft.is 8 in., 151 to 200 ft.is 10 in.and greater is 12 in 9X9po5rWl,Na,� SCALE,1/2'' _ 1'-0'' ANCACAF XF VFW rA TI2 8"FA50A W/2X6 5W FA5CIA COLUMN AMP 6FAM A55FWLY 12 @ FRONT 6A3U FNP5 ONI v^"-v-o' 16 5OFFIT MATFFIA,W/ MIML?CRNJ Ik5 NO FXF05FP 12 CAMS 8:12 FBI P AL 1. q e 0" (2)2X6'C 055 W/ ❑ ❑ 611 2X6 for&[3PAGfm. ❑ ❑ 6"FFOM fOF&3fM. I x 8 IXB �HUfTFF MOIJWr TIGNi"TO WINI70W RAW OVEF 5IJIN6 12 12 6 � � 6 X6 8 4 ® ®® 00 ® ®® 00 ❑ ❑ ® ® ®® RIM II '�` xFAXGOFNFF WOW VIEW PICK 51PF VIEW ✓ TRIM I"X2''11M RI"X12--MM I"XIZ"ipM TRIM @ CAW FOFCU M7F IX2 U61FIM zo 5OFFITMATFRIAI, F 3> IX4 Ufa Trim IX2 W TFIM 12 5/4X813A' 6 OrCH SLAP 2Nn FI00R(U—N6 _ 17 IFMI 2NI)FL22k I51 F1002 LEII.IN'n _ ❑❑ ISiFi00X PACK VIEW I.ffT 51PF VIEW MN6&OWEL�VAION CITY APPROVED PLANS 5CA,F I/4"-I'-0" Reviewed for Code Compliance PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Page 11 of 14 TRUSS DESIGN AND LAYOUT SHALL BE CBH HOMES PROVIDED AT FRAMING INSPECTION PROVIDE MEANS TO RESIST UPLIFT AT 6 -2 GPANPV FW F5TATF5 # EACH LOCATION SHOWN ON TRUSS 2X10 MIN. RIDGE FOR DESIGN DETAILS OVERBUILDS W/2X6 MIN. RAFTERS @ 24" MIN. O.C. PROVIDE COLLAR TIES FOR HAND PROVIDE FULL HEIGHT STUDS FRAMED ROOF RAFTERS IN BEARING WALLS BELOW ANY GIRDER TRUSS LOADS ABOVE. EACH TRUSS PLY TO HAVE A STUD BELOW. (2)2X 12 HM ° IIII IIII IIII IIII IIII �III:• II II —pr.F GII IM 1IPI U5 5 IN IIWII&L ROOF FRAMING PLAN MAY (2)2 X 10 M5 22X,o (2)2 X IO WY5 11 TT TT: TT — NOT MATCH FINAL TRUSS — — — .....— HP II O . S III , II I II II II II II II II II II II II II II II ALL GIRDER TRUSS LOADS II o II II II II o II II IIII II II II II o II II II III ON TRUSS FRAMING III l l LAYOUT FROM MFR. IIII II II II II; II II II ; ;II II II II IIII II II II II II II II I I I I I I I I I I I I I I I iiI I III g I I I I g I I I I I I I I I I I I I I I I I I IIII II II II 4 II II II IIII II II III III I II � II II II II II II II II II II II � II II II II I II II II II II II II II v I I I I I I I I I I I I I I I I I I II II II I I I I I I I I I I I I I III I e —I12) II II III -- III II II _ �(IP 'L Q DII-0/ 'LVI,(W c2>I�4�..�-L�hc ) — — —LN.( ) -- I�``I==�II I I I II II I I r-'Lj� II II II II II II II II II III - _ - - _ - -_��_ I I I I I I I I I I I I II II II II II II II II II III - _ - - _ - = J I I I I I I I I I I I I I I I I I I I I I I co I I I I I I I I I N I I I I I I I RE 19�FL�ORfk1JY�5�2A"0/C � N II II o II II II II II II II III = - _ - - _ - Lu I � a:-a:-a. .l:-.l:-.l:-a - p�Gl�n�� - I I I I O I I I I I I I I (2)9I;7 LAW;FLEAS — — — — — I II II � II II II II II II II III _p�.Gl�n��,�I� _ I 22 6HVP5 I I II II II II II II �U � N U p.ES R CfMGA6 Ei11155 ..........—.�.....—... ..:_......:—..:—... — — — — — — — pf GI PM55 O @) (2)2X6 UR5 (dj EMI -I-� � �2>2x� EIS o� <2>;XIZwN Hbk5W9 FILL 0 �2�ZX Z Hn�S W�pi���� N Q � - - - - - - - - -(z�u�ia��wiHn� - - - - - - - - —�- -�—"(2)II9/eIl wHnk - - - - - - - FLOOI? FP\AMING PLAN xA,p I/all=1'-0" t?00F I'MMING PLAN 5CA. :I/all-I',QII CITY APPROVED PLANS Reviewed for Code Compliance PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Page 12 of 14 [ CBH HOMES oRACEn W",I IN' EP.ALMn w4LL LINE fWPLE.WN.L LINE EP.ALM.W4LL LINE 6 /2 G BAN P V f W n MQUIMP 2.8' L MQUIMP 108' 6 MAI 159' A MQUIMP 90' Pp.OVInMn 80' p�O 1 120 PROVIWV 228' Mooprr 120' 3,,bll Z-611 4'_011 2`011 PRACFP MaM WALL LINE RRP.PLF,n 6 LINE W p 51U,@ 42' WSP FFWVInFP 120' MOVIv P Iz0' q 0'' 6 036 SLQ, g.O M I-6" 11'.41I 6RPCE1)WALL uNE � Fh(YJIREn 9,4' GkA!ED WPI,LLINE OO '"PEP 12,0' ITOIIMP I I2' W5p I — W5P pRO n n 120' W5P W5P W� WP 40405LCL 6'-0" 4°4°5�CL 4°4°JCL 4°4°5�CL yo610 P/700R 5 CL 50y0 pFo W5P W5 w5P — —�— — II (2)2%12NGY5 x12Nnks 1 I I 3>STNnl4 W5P p I I I 11 II I I I p II I I I II I I I II I I II _ j1 II - I I I I I I I CFPLEn wNALINE —— LA/C W5P WOUMn 9,2 W ---- W W5P€ ° N o wo OVInRn 22 i II 2 P II 6 3 . 8 z 6 9 W5P 4 o UI O O v W-0 W5P I II WT ❑ ----- ° � , q-0 Nw 1 i j I I �i o qq II 11 0 � �Pasr 1 II II I I II II I� M I. kE: �IiWALL PANEL GEARING WAL o `i` XAC'l WA.L IINIFMau1n 86' PLANT5NNLF(2)2%12 NTS MOVIPNP 95 9/16"AFA-1`�EA 1. °y° W/GRI175W5PNA, LW5P2'-w' 3'� II�2a.p,FzC5 uFswnwA.LLILe 4°4°�W/GRII75 6"OCAfFIEIn MOUMn r2 I/I6"APA PATED'AMTNING NoW5P bd NNL56"OC.PANEL "0�� 9C ALNN P11/2"fAPlE516COWa FAN�iW5P 6"OLAfNE n 5F® � C� PPG 5MnEfAI 4050%W/GP.15 40y05LW/GRID5 0° 8°7°ONn00p ° f5r EZACEn wa,L 8W 6„ mouorn ae' P 5REPNMI, I4'-T 16070ON Poop FROAMP 9.0' II PEG 2) '7/86 vLNI7R PEG ---�D PEN SEEneraL NNAI7NR NOTE', Is as 13/8"50MW -0^ o" GG >"OCAfEDCE5 a • GOTTOM OF NEATER AT 6''112" 101'01, 16'-211 4'7Y2 for DONOM FLAT LINLN55 NOfEn OMNRWISN(LI.N 0) 'i FA5VN 5H AWING to WE PNP w/89 S�CONb�L 00� • (2)2X6 HPF5 LINO COMM NAL51N 5 ON "6Lpn FAT1FrN A5 E%1ENIR NGP.(2 G'R4LEn WAIL SEGMENTS) a 0'oc.IN FRAMING A5 rX1VNf Of wx a TSFACF2 WALL SEGMFN° • ALL NNA W5 ON N 2CF FIGHT P602.10.6,4 FASTEN 5EAHIIN6 fa FEAMP W/&n 6-IOVvN(sNnseslLLs)rw. ��Sr� 00� XSWOFNnR . &L NEAPNR5ARE#2 POLIO.FIR ME1NOfl C59'F-CON9NUOu�,Y 5-EA1NEn I'OI:7N.N'JWIE GANEI CONSIRLIC9oN COcoMMON Nags 1N 5^2 CRID PAriMkN <2 f%RPLEn WALL TGMEN15) AS`kION B 15 O.C. RAMING AS 2'-I N n WI0L NAL MIN,3w1,25"NEf IiR. ernxra rewrevnmcaaevicerK wives<rvaezravwkevus.n A55HOVN&52O.C. FR rOFFLATCONfiNIu1Y15�0� MIN.IOOq,6 NGK f0.WCK SrW SiRa' FOR ANGLE CR nOL6LR pORfPL TOP OF W&ICLIIRb R%fENf GF NGk PER ML11ON V6023.2 ON n0M SIGE5 Of OPENING no TOP OF WN.L wR NAIL o FA En ro KING n oRURX W L`EGME b02.106 a(INI ON DACK511 TOP Of ARCNWAYS ARE 12"FpOM TOP rwueeare ezraowa.em�.� aaenmxa W/b-I6n ANKER NNLS SIDR ELEVATION 2 X �X �10� W/��5 ONLY _ OF 9'P�AltAFCH AY5ANOT'FOMfOP MIN 10001.E WE TO JACK 5TT 5rPAP fcv PLATE ro NEAGEP W/2 ROW5I6n -TOP OF ARCNWAYS A 7"PROM TOP -JI Il wuarceaEeuoee .. vv rswme av A591OWN) :.: OL, AiPLL EE q.GLKE ... ... ........ -.e��xn.xmxam�x�� nww«� M1ND"wLzb"NerwR, POW KEPNNL5AfV"OC.r` OF8 PLATEUNLE55NOTEPONINPW115E P60210.41.1(IN5fNLONISALKAGE IN wN CITY APPROVED PLAN wurzeanvvenceo ON DOfN SIDES OF OPENING PER SIN Tun rw,zar A1a.L BM FLOCKED PW OLLNP WIMIN µm n SINKER IN $ . vroz snJxnra I6 .. -ARr>^Em`FtnEST'e3rznrz.¢Er aldirtolF.m- Il earu.aecreun.a+ee Nnp OF 01cc � EL 9'I.ILE( nANf1 CCLIlR WIM�INS 1 000 L6 �� r' �� rO FRAMING IS MO.IN RA Reviewed f Code Compliance IlµnNcewcaes4^ane bocrrerare 29 OF MIDNGfOf`E POW OfiW "�� p�LfMIDNGf.ONEPOWOFfW g CI fL1 mpl" pa EL�E1�(AS�Q,)PANELED�S NnANC I. 29" v xv ixe vnrna vpnx IIa^°.c xwrGe�c�um Nnpro JPLK Brun ��OOp pL� 91E rN1NG cx Il vpus.¢os. SrRAp5ON 60M AnE5 N1NG to FMIN615 MO,IN EA v/16''5MVIRA FARIF,9fAfNING PANEL Mw(2)�KS E' PLANS MUST BE ON JOB SITE 3 xesacrexne as°sre 5cea w II Il rerq.vvwre OF GPMNNG _ �x��ell II SCALN:1/41I=I�,OII w/(oaNGsrun zmr I'wx.caei.e as rmr<ure MIN(2)2%9 FRAMING i1P quo�s�ne ,ro,m°eNnereuulwcsnm II i I sxr;mlx �'re°''e'�" MIN WInM-lb" ONE SILKY MN(2)2%91W 15QFf FTFINIO FOR ALL INSPECTIONS u u�s�sree�.e, I v I6"o�AnA 27 50 PT FIRST FLOOR MIn.WmN-2a'FaP NRsr Of x ,� ","`°°.><°•`v. MI MWAPA51 N9d111,10 F �sr rlxa. 149350PTSECONI7PLOOR rwosra�5r n �uxen9°wre�xu,ae�oanixsrx�eooEe e g vw 1 LENGM RATIO MIN,9200 L611E naWN IN LGKEMIE 44 738 50 Nr GAp.AGE ). F(,_ �' MIN 25"Y3/I6"PLATE WA51ER N&NO r0 FRAMING AN710R60LrFERRFJO.16ff 9350FTCOVEpE17PORCN 5/e"nvMErEP MINI000Lr:flenowN 20 50 PT COMND PAi10 ANILNok oaf MIN,Z u..0/16"FLAIR wA ER Mw I2°x I2"Foo NG uN�R PEG POKAL W.AMN @ GAPAGE LEwEtn 1N PANEL OFENwG.f F O=9 LAP TOPIR sveexcncu PIY44'RDOLf PER ANN,6M, OOT10MOf FOOTING,LAPW GAR AN MIN FMGNfELEVAnON mil° 5FenoN 5LAM/+v _I'-0" PFNPOK&FPPAME Page 13 Of 14 [ CBH HOMES 12 S(OF A6 WfFl7) PITCH ASPHAJLT 5HIN61,F5(\/FrIFY TYPF ANF COLOR) 5#FFLr 7/I6"FXT.0513 W/CLIPS IF--IN5u,A11ON 6AFFI E5 2"AIR SPALF r.P N MJ55E5 24"o/C A5 SPFCIrIFF MAS P CL05�f FAACIAA55 aNINF vFN SOFFITA AS IF P fs s sPFaFIFF @ e'-o" R-3B A OW-IN IN5ULA11ON(MIN) MA5tP\ PM,00M �f Pplo0M 2 X 6 5TT5 @ 161,0 C, FXTFRIOR I-Offfm P(Tyr) N %P FLOOR A5 5PFCIFIFF FFCKING P.F.1411 FLOOR TP.J55F5 @ 24"o/C (OR AS NOTFF) pANTPY I/2"OYP 2 X 6 5TJF5 @ I611 O.C. /2"GYP 4 MIL VAPOR PAWIrr 2 X 6 FXf.5TUF5 @ 16 0 C bI N I NG KI1 CND N nr N SIFING AS SPFCIFIFF � Y/Ib"05r3 Fur.sHFAnNG R2I GATT IN51KON(MIN) ® ®® o000 ® 9I/2"I-JOI5T524"0/C 50 FLOOR A5 5PFCIFIFF E =1] 3/4"FFCKING 65 nM�NI IPCI0pSF@ �� M6T 'FOM ONF FR ATF FINI9I6MF Ir PROVIDE DAMP PROOFING ON TOP MOJNT F<FlNGFR W/FA3 OF ALL EXTERIOR FOUNDATION j A7HFA6IVF IN SFAT @ J0I5f TFRMINAnoN WALLS BELOW GRADE =I I I _ Q 2 X 4 PONY WALL @I6"O.C. — FINI91 GRAFF —1 e 6 x a"coNc FoonN6 —11 (u#4 PAR HORIz @ for of WA L,(u#4 —III 6 MIL VAPOR FMIFR = N - f3AV HORIZ @ ALL FTG W/ #4 6AR VFRf 4"o C fo FTG. 2 X 4 PONY WALL @ I6"0 C 5UNPANa 2110 MIL CONIC Fo0nN6W/(I)#4SARHORIZ 6 MIL VAPOR(3APRIFR FOUNFA11ONPINNFORCFM%f TWIN FA,, 5/� CP055 5�C110N CITY APPROVED PLANS (D-4M1'It FPH0VZONfALIYf0`OFFNHW&II I !.�I I I (1)^4PAFR N2H0RZ0Nf&,YWFNI7.Ff6(1)�4PAFf4KFAVE2X&Y.4d"OL, —011 Reviewe a Compliance or Co (1)44PAF N.PLFV HgZON%,YIN PONY WA.I F1;: PLANS MUST BE ON JOB SITE FOUNPAWN I MIN ABOVE CUPP FOR ALL INSPECTIONS Page 14 of 14