Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
99-0345 240 Addison Ave W - Plans
' 1997 UNIFORM FIRI CODE 5201.6.2 5202.3.9 extinguishers. A method of communicating with the fire depart- accordance with Section 5202.3.6.Class II and III-A liquids shall ment shall be provided for the attendant. be stored in containers or in tanks located underground or in spe- cial enclosures in accordance with Section 5202.3.6.See also Ap- 5201.63 Unsupervised dispensing. Unsupervised dispensing pendix II-F. is allowed when the owner or operator provides,and is account tanks and- able for,daily site visits,regular equipment inspection and main- 5202 ground2 tanks. A conneInterconnectioction of abovshal round u d made between r- tenance,conspicuously posted instructions for the safe operation an of dispensing equipment, and posted telephone numbers for the aboveground tank and an underground tank. owner or operators. A sign, in addition to the signs required by 520233 Fueling from portable tanks. Portable tanks are al- Section 5201.8,shall be posted in a conspicuous location reading: lowed to be temporarily used in conjunction with the dispensing of C1assl,II or III-A liquids into the fuel tanks of motor vehicles or IN CASE OF FIRE,SPILL OR RELEASE other motorized equipment on premises not normally accessible 1. Use emergency pump shutoff! to the public when approved. 2. Report the accident! 52023.4 Storage tanks at bulk plants. Storage tanks used for Fire Department Telephone No. fueling operations shall not be connected to or serve as bulk plant Facility address tanks. 52023.5 Class I liquids in basements or pits. Class I liquids During hours of operation, stations having unsupervised dis- shall not be stored or used within a building having a basement or pensing shall be provided with a fire alarm transmitting device.A pit into which flammable vapors could travel unless such area is telephone not requiring a coin to operate is acceptable. provided with ventilation designed to prevent the accumulation of 5201.7 Sources of Ignition. Electrical equipment shall be in ac- flammable vapors therein. ac- cordance with the Electrical Code. 52023.6 Special enclosures. When installation of tanks in Smoking and open flames shall be prohibited in areas where cordance with Section 7902.6 is impractical,or because of proper- fuel is dispensed.The engines of vehicles being fueled shall be ty or building limitations,tanks for Class 1,II or III-A liquids are allowed to be installed in buildings in special enclosures as fol- stopped. lows: 5201.8 Signs. Signs prohibiting smoking, prohibiting dispens- 1 The special enclosure shall be liquidtight and vaportight. ing into unapproved containers and requiring vehicle engines to be stopped during fueling shall be conspicuously posted within 2. The special enclosure shall not contain bsure shall be of re- sight of each dispenser. 3. Sides,top and bottom of the special enclosure shall 5201.9 Fire Protection. Portable fire extinguishers shall be pro- inforced concrete at least 6 inches(152.4 mm)thick,with open- vided as set forth in UFC Standard 10-1. ings for inspection through the top only. 4. Tank connections shall be piped or closed such that neither 5201.10 Clearance from Combustible Materials. Weeds, vapors nor liquid can escape into the enclosed space between the grass,brush,trash and other combustible materials shall be kept special enclosure and any tanks inside the special enclosure. not less than 10 feet(3048 mm)from fuel storage vessels and fuel- 5. Means shall be provided whereby portable equipment can be handling equipment. employed to discharge to the outside any vapors which might ac- 5201.11 Maintenance. Fueling systems shall be maintained in cumulate inside the special enclosure should leakage occur. proper operating condition. 6. Tanks containing Class I,II or III-A liquids inside a special enclosure shall not exceed 6,000 gallons(22 712 L)individual or SECTION 5202---FLAMMABLE AND COMBUSTIBLE 18,000 gallons(68137 L)aggregate capacity. LIQUID MOTOR VEHICLE FUEL-DISPENSING 7. Each tank within special enclosures shall be surrounded by a STATIONS clear space of not less than 3 feet(910 mm)to allow for mainte- 5202.1 General. Automotive,marine and aircraft motor vehicle nance and inspection. fuel-dispensing stations utilizing flammable or combustible liq- 52023.7 Cont.-ner storage inside buildings. Class I, II or uids shall be in accordance with Section 5202.See ak:;o Article 79. III-A liquids stored inside motor vehicle fuel-dispensing station 5202.2 Approvals. buildings shall be in approved containers and in accordance with Section 7902.5. 5202.2.1 General. Equipment and appliances used for the stor- age or dispensing of flammable and combustible liquids shall be 52023.8 Testing or leak-detection devices. Leak-detecting de- approved or listed in accordance with Section 5202.2. vices shall be tested annually by the owner or occupant of the property on which they are located. Test results shall be main- 5202.2.2 Approved equipment. Pits and piping used for flam- tained on the premises and available to the chief on request. mable and combustible liquids shall be approved. 52023.9 Inventory control. Accurate daily inventory records 5202.23 Listed equipment. Tanks, electrical equipment, dis- shall be maintained and reconciled on Class I,II and III-A liquid pensers,hose,nozzles,and submersible or subsurface pumps used storage tanks for indication of possible leakage from tanks and for the storage or dispensing of flammable and combustible liq- piping.The records shall be kept at the premises and availableprod- uct,shall be listed. the chief upon request and shall include records showing,by 52023 Storage of Fuel. daily reconciliation between sales,use,receipts and inventory on hand.If there is more than one system consisting of tanks serv- 52023.1 General. Class I liquids shall be stored in closed con- ing separate pumps or dispensers for a product,the reconciliation tainers,in tanks located underground or in special enclosures in shall be ascertained separately for each tank system.A consistent 1-118 CONRAD BISHOFF Building Plane REVIEWED �4 0 W. ADDISON For Uniform Building With Uniform Building Code All Construction ADDISON STREET TWIN FALLS, IDAHO .Subject to Field Inspection — -- -- — -- — DO 04 ADA STD. RAMP ACCESS TYP. F ADA STD. RAMP ACCESS TYP. 4' VALLEY CUTTER 4' VALLEY CUTTER `\ SIDEWALK SIDEWALK SIDEWALK e^vane d app� m M y �" t d� N ti 3 �i z r. o L�� .. J7.2' 372� p 3 FIndlnsp dw PWquYMBEF0AEuwmaaww — 1 5 GAS PUMP CANOPY AL SP R ESTS h INSPECT CARES NON T REC DI 725-'�p. +`-- o S8j I9 ;,I��'i Wine:733-6695 W Gn ro a+eY ti l v w �I 18' — — —— — — ti 78' 18' --.� Q — w EXISTING BUILD I G 385J SQ. FT h a a— SCALE: 1 "-20' 72' / / 1 29' -- a 4 — R6rr-L4fyypbLlf�i.d�P I11�G/'is¢/ or /1C iQ�cV �✓ -�/ � -�' L 7' � h 0, le style o����,9 S��.I/e --- u�Le�sli& he >�r1f rW71 !✓�ere- 77' A// Ze /X4 7� /�2G i✓ �u / W �P5 0P� ECEIV •s 5� 9 �P orOFTWM" ILD!KC DE FT 7. I i / z STORAGE TANKS LEGEND Z m CONCRETE W > .0•O Cr _ "5' I 40, STRUCTURE CONRAD fSHN%W, 0 195' SITE N 0 240 W. A U HARPER—LEA VITT ENGINEERING, INC. MP NO.: 99625 SHEET / PROMWIONAL ENGINEERS AND LIND SURVEYORS DATE.• —16-9 1 iS BOO W.JULYCNL Sr,P.O.BOX 864 BLICKFOOF, - IDAHO SJ221 (206)785-2977 OR 2990 ORIIK BY, RLR 985 N.GPMAL AYE,P.O.SOX 50691,/LWM FALLS CHCED, BY.KHL OF-r ILWfO BJ405 (208)524-0212 SJ7 AoWN sr.PO."696,SALA/ON LYWYIIiCJI!©19Y8 NL! IDAHO 8J467 (208)756-8371 Au MOMS MSfiPIfD. 89' SCALE: 1 "=4' CONCRETE SIDEWALK T:75' 2' d11A C`1 S T019A GE Y EXISTING BUILDING Y J85J SO. FT. OFFICE 1003'3.1.8 Type of lock or latch.Regardless of the occupant load served, door,shall be openable from flie made without ,be.,c of a c t or any special knowledge or fifori E I tt(�NS:1.In Diann,&Di—ion 3:D:F�M ad S Ov ,an,".s.odi U,h lao.key-lucking hitol—v ar.y te,used on the anon�.a h_1,onto.it consists f,single it.,.,road doom 115' whcnv Ilinna i,a noxii[y"aiblv,d,utibl,sign an.adjacent m Ine it-, among, 11115 DOOR MUST REMAIN UNLOCKED DURING INESS FIOURS."The sign shall he in letters not less'than I itch N (25 man)high no.comran.,background.When unlocked,the ain& don,or both leaves of a pait of doom.,.at be tree to swing without pnour"of "Y latching device.Tla,use of thi.,exception .Y N vol,ad by th.building offi,m]for do.auto. J2' WOVE-IV's MEN IS Esi,"'from nulwal,.1 da,dii,g aita:Group R.Division 3 con,pin.tun.ni accl;and guest mannsof Gm.,R O—p-re a,an IZA of 10.,Ics.,may It,pvidtdh.night h"h' RE'S T RE-5 land holl of"'tority chain.p—id,d wh dalien.,—"Po2bl"ft.. tU the inside without the—of,key I,,tool and asonand at a height not to a.. ROOM ROOV, no 11 inches(1219 anno..—ha finished floor. operated edge-or surface-mounted final bolls and surface bolls or any other type of device that may be used to close Li (CY C"' or restrain thedoor other than by operation of the locking device shall not used.Where exit doom am used in pairs and approved a. i Flush bolts are used,the door leaf having the automatic WALK—IN flush automatic ��h bolts shall have no doorknob or surface-mounted hardware. (_U COOLER on. unlatching of any leaf shall not require more than one opera- EXCEPTIONS:I.Group R.Division 3 an I wbe,a.Fair of doom ne—,.ma=].I._A,acc.ps,d is dad for the ,,,dequapan.to. II ed,,, so _..on,= d— d "a an.be used. RECEIVED JUN 171999 OITY TWf FALLS 13UOFluy�lct E I S I-ORA GE Ot3c FLOOR PLAN CONRAD RISHOFF FLOOR PLAN fY U HARPER—LEA VITT ENGINEERING, INC. JOB NO., .9626 SHEET PROFESS70NAL MIAGEMUS AND LAND SURVEYORS 2 kj 800 W JUDICW Sr.,P.O.ear8W,aLACKFOOT, 3IDAHO 8J22 1 (208 785-2977 OR 29.90 Cot 965 N.CA-Irk AVE,P.O.)BOX 50691,)OA O FALLS OF IDAHO 834- 08)M4-0212 j 5J7 UNN P.O.sr, Box 596, -W&'ON IC[.ADAHO W467 (208)756—&121 AL RAraso'S R"In"FO 2