Loading...
HomeMy WebLinkAboutTHE SPRINGS AT THE PRESERVE SUBDIVISION (CONCRETE) 08-25-20 SUBDIVISION DAILY INSPECTION REPORT Project Name: The Spring's at the Preserve - Twin Falls, Idaho Weather: 88' F., Sunnv Date: 08-11-20 Job No.: 161-17 EHM Representative: J. Cazeau Contractors Name: Lancaster Trenching Contractors Representative: Ben Area of Inspection: ❑ Water Line ❑ Sewer Line ❑ Storm Sewer ❑ Pressure Irrigation ® Streets ❑ Gravity Irrigation Inspection and/or Testing Details: Pipe Diameter: ❑ 2" ❑ 4" ❑ 6" ❑ 8" ❑ 10" ❑ 12" ❑ 15" ❑ 18" ❑ 24" ❑ 27" ❑ 32" ❑ 48" Pipe Type: PVC Pipe Class: C900 Valve Type: Valve Class: Pipe Depth: (36" Minimum) ❑ Pipe Bedding Inspection: In Conformance: ❑ Yes ❑ No Bedding Type: ❑ Thrust Block Inspection: In Conformance: ❑ Yes ❑ No ❑ Pressure Test Observed: In Conformance: ❑ Yes ❑ No Deflection: ❑ Yes ❑ No ® Density Testing Item: M Trench ❑ Subgrade ® Base ❑ Asphalt ❑ Utility Trench ® Concrete Testing Item: ® Sidewalk ❑ Curb & Gutter ❑ Valley Gutter ❑ Driveway Specific Location of Inspection and/or Testing from approved plans: Subgrade inspection of sidewalk (See separate subgrade inspection report for location and results) Review By: William J. Nenno, C.E.T. 621 North College Road -Suite 100 "'tEl-IM E Twin Falls, Idaho 83301 IllI1 "S, Inc. Ph. 208-734-4888 Fax 208-734-6049 o ' ' BU(LDMG THE FUTURE ON A F"OATION OF EXCELLME SUBGRADE SPECIAL INSPECTION REPORT Project Name: The Springs at the Preserve - Twin Falls, Idaho Weather: Sunny, 88°F. Date: 08-11-20 EHM Job No.: 161-17 EHM Rep.: J. Cazeau Contractors Name: Lancaster Trenching Contractors Rep.: Clint Type of Inspection: Subgrade Evaluation Geotechnical Report Provided: Yes No X Subgrade Soil Description: Sandy Silt Location of Work: NE Sidewalk off of Clear Springs Loop connecting to parking area Specific Details Inspected: ® Soil is Native ® Soil is Free of Roots and Debris ® Visually Observed Proof Rolling of Entire Area Equipment utilized for Proof Rolling: Penetration resistance with Jones probe ® Area observed was firm and unyielding SUMMARY: M Work was in general Compliance with the approved plans and specifications ❑ Except as follows: ❑ Re-Inspection is required. NOTE: Reviewed By: illiam J. Nenno, C.E.T. 621 N. College Rd., Ste. 100, Twin Falls, ID 83301 Phone: 208-734-4888 Fax: 208-734-6049 SUBDIVISION DAILY INSPECTION REPORT Project Name: The Spring's at the Preserve - Twin Falls, Idaho Weather: 91° F., Sunny Date: 08-12-20 Job No.: 161-17 EHM Representative: J. Cazeau Contractors Name: Lancaster Trenching Contractors Representative: Ben Area of Inspection: ❑ Water Line ❑ Sewer Line ❑ Storm Sewer ❑ Pressure Irrigation M Streets ❑ Gravity Irrigation Inspection and/or Testing Details: Pipe Diameter: ❑ 2" ❑ 4" ❑ 6" ❑ 8" ❑ 10" ❑ 12" ❑ 15" ❑ 18" ❑ 24" ❑ 27" ❑ 32" ❑ 48" Pipe Type: PVC Pipe Class: C900 Valve Type: Valve Class: Pipe Depth: (36" Minimum) ❑ Pipe Bedding Inspection: In Conformance: ❑ Yes ❑ No Bedding Type: ❑ Thrust Block Inspection: In Conformance: ❑ Yes ❑ No ❑ Pressure Test Observed: In Conformance: ❑ Yes ❑ No Deflection: ❑ Yes ❑ No 0 Density Testing Item: ❑ Trench ❑ Subgrade 0 Base ❑ Asphalt ❑ Utility Trench ❑ Concrete Testing Item: ❑ Sidewalk ❑ Curb & Gutter ❑ Valley Gutter ❑ Driveway Specific Location of Inspection and/or Testing from approved plans: Density testing of sidewalk (See separate density test report for specific locations and results) Reviewed`By: William J. Nenno, C.E.T. 621 North College Road - Suite 100wle Twin Falls, Idaho 83301 LAM Engineers, Inc. SURDMTHE FUTURE ONAFOUNDATION OF EXCEUEt4aE Ph. 208-734-4888 Fax 208-734-6049 4 EHM Engineers, Inc. SUUMG T"E FUTURE ON A FOUNDATION OF EXCELLENCE In Place Density of Soil - Aggregate By Nuclear Method Date: 08-12-20 EHM File No.: 161-17 Project Name: The Springs at the Preserve—Twin Falls, Idaho Contractors Name: Lancaster Trenching Building Permit No. : NR Inspectors Name: J. Cazeau Nuclear gauge No.: 28754 Maximum Optimum Material Material Description Material Source IFDensity, Moisture, # p PCF "�o Standard Used -1 19mm Base Stutzman Pit 116.0 12.0 AASHTO T99-D TEST RESULTS Structure Description: Sidewalk Base Test Probe Wet Moisture Dry Required # Depth FElevation Location Density, Content, Density, Percent Compaction, Pass/ (in) (pcf) % (pcf) Compaction % Fail 1 4 100.0 20'W.of C&G on 115.E 3.9 111.2 96 95 P Clear Springs Loop 2 4 100.0 30' S. of Walking Path 120.E 3.8 116.1 100 95 P 5' NE of Sidewalk on : I 3 4 100.0 Clear Springs Loop 118.6 4.6 112.0 97 95 P 4 4 100.0 L5' SW of Walking path 116.2 5.9 109.7 95 95 P 100.0=Top of Finish Base Review by: i liam J. Nenno, C.E.T. Laboratory Services Supervisor 621 North College Road—Suite 100 Twin Falls, Idaho 83301 Phone: 208-734-4888 Fax: 208-734-6049 SUBDIVISION DAILY INSPECTION REPORT Project Name: The Spring's at the Preserve - Twin Falls, Idaho Weather: 63' F., Sunny Date: 08-13-20 Job No.: 161-17 EHM Representative: J. Cazeau Contractors Name: Lancaster Trenching Contractors Representative: Ben Area of Inspection: ❑ Water Line ❑ Sewer Line ❑ Storm Sewer ❑ Pressure Irrigation ® Streets ❑ Gravity Irrigation Inspection and/or Testing Details: Pipe Diameter: ❑ 2" ❑ 4" ❑ 6" ❑ 8" ❑ 10" ❑ 12" ❑ 15" ❑ 18" ❑ 24" ❑ 27" ❑ 32" ❑ 48" Pipe Type: PVC Pipe Class: C900 Valve Type: Valve Class: Pipe Depth: (36" Minimum) ❑ Pipe Bedding Inspection: In Conformance: ❑ Yes ❑ No Bedding Type: ❑ Thrust Block Inspection: In Conformance: ❑ Yes ❑ No ❑ Pressure Test Observed: In Conformance: ❑ Yes ❑ No Deflection: ❑ Yes ❑ No ❑ Density Testing Item: ❑ Trench ❑ Subgrade ❑ Base ❑ Asphalt ❑ Utility Trench ® Concrete Testing Item: ® Sidewalk ❑ Curb & Gutter ❑ Valley Gutter ❑ Driveway Specific Location of Inspection and/or Testing from approved plans: Concrete testing of sidewalk (See separate concrete test report for specific locations and results) Reviewed By: William J. Nenno, C.E.T. 621 North College Road -Suite 100 Twin Falls, Idaho 83301 E -" � Engineers, Lac, Ph. 208-734-4888 Fax 208-734-6049 SUBDIVISION DAILY INSPECTION REPORT Project Name: The Spring's at the Preserve - Twin Falls, Idaho Weather: 64' F., Sunny Date: 08-14-20 Job No.: 161-17 EHM Representative: J. Cazeau Contractors Name: Lancaster Trenching Contractors Representative: Ben Area of Inspection: ❑ Water Line ❑ Sewer Line ❑ Storm Sewer ❑ Pressure Irrigation 0 Streets ❑ Gravity Irrigation Inspection and/or Testing Details: Pipe Diameter: ❑ 2" ❑ 4" ❑ 6" ❑ 8" ❑ 10" ❑ 12" ❑ 15" ❑ 18" ❑ 24" ❑ 27" ❑ 32" ❑ 48" Pipe Type: PVC Pipe Class: C900 Valve Type: Valve Class: Pipe Depth: (36" Minimum) ❑ Pipe Bedding Inspection: In Conformance: ❑ Yes ❑ No Bedding Type: ❑ Thrust Block Inspection: In Conformance: ❑ Yes ❑ No ❑ Pressure Test Observed: In Conformance: ❑ Yes ❑ No Deflection: ❑ Yes ❑ No ❑ Density Testing Item: ❑ Trench ❑ Subgrade ❑ Base ❑ Asphalt ❑ Utility Trench 0 Concrete Testing Item: 0 Sidewalk ❑ Curb & Gutter ❑ Valley Gutter ❑ Driveway Specific Location of Inspection and/or Testing from approved plans: Concrete testing of sidewalk (See separate concrete test report for specific locations and results) Reviewed By: l William J. Nenno, C.E.T. 621 North College Road - Suite 100 Twin Falls, Idaho 83301 LIIM EnIgineery, Inc. ft"NG THa 5UIURE ON A FOUNDATION OF EXC UEWE. Ph. 208-734-4888 Fax 208-734-6049