Loading...
HomeMy WebLinkAbout19-3048 2322 Bisbee Place City Approved Plans 8'1 8 Office 11 6" If 11 , 7 Great Rom/Entry 'Kitch n/Dininq/ ivinq 1/2 B�t North 8'1 6 611 Audi o s al Pantry Bathroom^ 81 I1 n ^d^ Bedr m 2 'dden 1 1 1 " 6" MIN. O.A. DUCT Drawn: O Approved: Date: Job Number: CITY APPROVED PLANS ' PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS if 811 811 11 6" MIN. 8 Loft ���_' uT 891 z rth 1 11 Master Suit Master 8 WIC Drawn: Approved: Date: Job Number: CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Mike Shetler HVAC Load Calculations for Precision Heating RHVACRESIDENTIAL HVAC LOADS Prepared By: Steven Shoemaker Precision Heating Sunday,August 18, 2019 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Rhvac -Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Pioneer Heating&A/C Mike Shetler Twin Falls, ID 83301 Page 2 Project Report General Pro1ect Info ffrlation Project Title: Mike Shetler Designed By: Steven Shoemaker Project Date: Sunday, August 18, 2019 Client Name: Precision Heating Company Name: Precision Heating Company Representative: Steven Shoemaker Tesign Data Reference City. Twin Falls AP, Idaho Building Orientation: Front door faces North Daily Temperature Range: High Latitude: 42 Degrees Elevation: 4150 ft. Altitude Factor: 0,859 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 2 1.18 80% n/a 70 n/a Summer: 95 61 14% 50% 75 -36 Check Figures Total Building Supply CFM: 1,940 CFM Per Square ft.: 0.709 Square ft. of Room Area: 2,736 Square ft. Per Ton: 935 Volume (ft') (Above Grade). 41,082 Volume (W) (Total): 41,082 Building Loads Total Heating Required Including Ventilation Air: 95,541 Btuh 95.541 MBH Total Sensible Gain: 39.482 Btuh 100 % Total Latent Gain: -4,382 Btuh 0 % Total Cooling Required Including Ventilation Air: 39,482 Btuh 3.29 Tons (Based On Sensible + Latent) Notes _ Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS C:\Users\mrste\Desktop\Shetler Down Stairs\Downstairs Shetler.rh9 Sunday, August 18, 2019, 5:14 PM Rhvac -Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Pioneer Heating&A/C Mike Shetler Twin Falls, ID 83301 Page 3 Miscellaneous Report System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 2 1.18 80% n/a 70 n/a Summer: 95 61 14% 50% 75 -36.33 Puct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. j)utside Air Data Winter Summer Infiltration Specified: 0.220 AC/hr 0.110 AC/hr 151 CFM 75 CFM Infiltration Actual: 0.020 AC/hr 0.000 AC/hr Above Grade Volume: X 41,082 Cu.ft. X 41,082 Cu.ft. 828 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 14 CFM 0 CFM Total Building Ventilation: 150 CFM 150 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 18.90 = (1.10 X 0.859 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: -21.22 = (0.68 X 0.859 X -36.33 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 64.24 = (1.10 X 0.859 X 68.00 Winter Temp. Difference) Winter Infiltration Specified: 0.220 AC/hr(151 CFM), Construction: Semi-Tight Summer Infiltration Specified: 0.110 AC/hr(75 CFM). Construction: Semi-Tight Duct Load Factor Scenarios for System 1 Attic Duct Duct Surface From No. Type Description Location Ceiling Leakage Insulation Area [T]MDD 1 Supply Open Crawl - 0.12 8 739 No CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS C:\Users\mrste\Desktop\Shetler Down Stairs\Downstairs Shetler.rh9 Sunday, August 18, 2019, 5:14 PM Rhvac -Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Pioneer Heating&A/C Mike Shetler Twin Falls, ID 83301 Page 4 Equipment Data - System 1 Cooling System Type: Standard Air Conditioner Outdoor Model: 186BNA060*0**A* Indoor Model: CAP**6024AL*+TDR Tradename: EVOLUTION SERIES AC Outdoor Manufacturer: BRYANT HEATING AND COOLING SYSTEMS AHRI Reference No.: 9377084 Capacity: 53,000 Efficiency: 14.5 SEER Heating System Type: Natural Gas Furnace Model: 987MA6610OV21 Tradename: BRYANT Manufacturer: BRYANT HEATING & COOLING SYSTEMS Description: Natural Gas or Propane Furnace Capacity: 98,000 Efficiency: 97 AFUE CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS C:\Users\mrste\Desktop\Shetler Down Stairs\Downstairs Shetler.rh9 Sunday, August 18, 2019, 5:14 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Pioneer Heating&A/C Mike Shetler Twin Falls, ID 83301 Page 5 System 1 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Bedroom 3 173 6,562 99 6.6 - 3,210 0 170 170 2 Bathroom 60 2,590 39 11-4 348 574 0 30 30 3 WIC 35 1,988 30 11-4 263 434 0 23 23 4 Hidden Room 32 1,877 28 11-4 246 406 0 21 21 5 Panty 76 2,937 44 5 - 659 0 35 35 6 Kitchen / Dining / 635 14,749 223 7.7.7.7 - 7,056 0 373 373 Living 7 Laundry 295 9,977 151 8,8 - 4,466 0 236 236 8 Great Rom / Entry 613 17,379 263 8.8.8 - 6,258 0 331 331 9 Audio/Visual 23 1,514 23 11-4 199 328 0 17 17 10 Bedroom 2 195 7,325 111 8 - 3,509 0 186 186 11 Office 564 17,135 259 8.8 - 9,339 0 494 494 12 1/2 Bath 36 1,873 28 4 - 411 0 22 22 Ventilation 9,637 2,834 -3,183 Duct Latent -1.199 System 1 total 2,736 95,541 1,299 39,482 -4.382 1.940 1,940 System 1 Main Trunk Size: 15x20 in. Velocity: 886 ft./min Loss per 100 ft : 0.056 in.wg Duct size results above are from Manual D Ductsize except where indicated otherwise. Runout duct velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize report for duct velocities and other data. ' Indicates duct sized with Rhvac's built-in duct sizing rather than with Manual D Ductsize. Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 3.29 112% /-12% 39,482 -4,382 39,482 Actual: 4.42 75% /25% 39,750 13,250 53,000 Equipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: 987MA6610OV21 186BNA060'0"`A* Indoor Model: CAP"6024AL'+TDR Brand: BRYANT EVOLUTION SERIES AC Description: Natural Gas or Propane Furnace Efficiency: 97 AFUE 14.5 SEER Sound: 0 0 Capacity: 98,000 Btuh 53,000 Btuh Sensible Capacity: n/a 39,750 Btuh Latent Capacity: n/a 13,250 Btuh AHRI Reference No.: n/a 9377084 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS C:\Users\mrste\Desktop\Shetler Down Stairs\Downstairs Shetler.rh9 Sunday, August 18, 2019, 5:14 PM Shetler Upstairs HVAC Load Calculations for Precision Heating Fji e ofto re m sivAc R$SIDBN`RAL HVAG LOADS Prepared By: Steven Shoemaker Precision Heating Sunday,August 18, 2019 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Rhvac -Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Pioneer Heating&A/C Shetler Upstairs Twin Falls, ID 83301 Page 2 Project Report General Project Information Project Title: Shetler Upstairs Designed By: Steven Shoemaker Project Date: Sunday, August 18, 2019 Client Name: Precision Heating Company Name: Precision Heating Company Representative: Steven Shoemaker lbesign Data Reference City Twin Falls AP, Idaho Building Orientation: Front door faces South Daily Temperature Range: High Latitude: 42 Degrees Elevation: 4150 ft. Altitude Factor: 0.859 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 2 1.18 80% n/a 70 n/a Summer: 95 61 14% 50% 75 -36 Check Figures Total Building Supply CFM: 1.537 CFM Per Square ft.: 0.808 Square ft. of Room Area: 1,901 Square ft. Per Ton: 768 Volume (ft') (Above Grade): 22,816 Volume (ft3) (Total): 22,816 Building Loads AW Total Heating Required Including Ventilation Air: 60,423 Btuh 60.423 MBH Total Sensible Gain: 33,684 Btuh 100 % Total Latent Gain: -3.984 Btuh 0 % Total Cooling Required Including Ventilation Air: 33.684 Btuh 2.81 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition. Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS C:\Users\mrste\Desktop\Shetler Down Stairs\Shetler Upstairs.rh9 Sunday, August 18, 2019, 9:42 PM Rhvac -Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Pioneer Heating&A/C 1 Shetler Upstairs Twin Falls, ID 83301 ' Page 3 Miscellaneous Report System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data REP Dry Bulb Wet Bulb RelHum Rel.Hum Dry Bulb Difference Winter: 2 1.18 80% n/a 70 n/a Summer: 95 61 14% 50% 75 -36.33 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0,00300 0,01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./l00 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. K)utside Air Data Winter Summer Infiltration Specified: 0.260 AC/hr 0.140 AC/hr 99 CFM 53 CFM Infiltration Actual: 0.000 AC/hr 0.000 AC/hr Above Grade Volume: X 22,816 Cu.ft. X 22,816 Cu.ft. 0 Cu.ft./hr 0 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 0 CFM 0 CFM Total Building Ventilation: 150 CFM 150 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 18.90 = (1.10 X 0.859 X 20.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: -21.22 = (0.68 X 0.859 X -36.33 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 64.24 = (1.10 X 0.859 X 68.00 Winter Temp. Difference) Winter Infiltration Specified: 0.260 AC/hr (99 CFM). Construction: Semi-Tight Summer Infiltration Specified: 0.140 AC/hr (53 CFM), Construction: Semi-Tight Duct Load Factor Scenarios for System 1 ] Attic Duct Duct Surface From No. Type Description Location Ceiling Leakage Insulation Area [T]MDD 1 Supply Attic 16B 0.12 8 491.4 MDD 1 Return Attic 16B 0.12 8 194.9 MDD CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS C:\Users\mrste\Desktop\Shetler Down Stairs\Shetler Upstairs.rh9 Sunday, August 18, 2019, 9:42 PM Rhvac -Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Pioneer Heating&A/C Shetler Upstairs Twin Falls, ID 83301 Page 4 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 1D-cv-o: Glazing-Double pane, operable window, clear, 370 14,344 0 15,610 15,610 vinyl frame, U-value 0.57, SHGC 0.56 12F-Osw: Wall-Frame. R-21 insulation in 2 x 6 stud 4075 18,012 0 4.051 4.051 cavity, no board insulation, siding finish, wood studs, U-value 0.065 1613-38 Roof/Ceiling-Under Attic with Insulation on Attic 1901.3 3,362 0 2,472 2,472 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation, U-value 0.026 20P-38: Floor-Over open crawl space or garage, Passive. 1901.3 3,878 0 570 570 R-38 blanket insulation, any cover, U-value 0.03 Subtotals for structure: 39,596 0 22,703 22,703 People: 0 0 0 0 Equipment 0 0 0 Lighting: 0 0 0 Ductwork 11,190 -801 6,012 5,211 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 150, Summer CFM: 150 9,637 -1183 2,834 -349 AED Excursion: 0 0 2.134 2,134 Total Building Load Totals: 60,423 -3.984 33.684 29,700 Check Figures Em— Total Building Supply CFM: 1,537 CFM Per Square ft.: 0.808 Square ft. of Room Area: 1.901 Square ft. Per Ton: 768 Volume (ft3) (Above Grade): 22.816 Volume (ft3) (Total): 22,816 Building Loads � i Total Heating Required Including Ventilation Air: 60,423 Btuh 60.423 MBH Total Sensible Gain: 33.684 Btuh 100 % Total Latent Gain -3,984 Btuh 0 % Total Cooling Required Including Ventilation Air: 33,684 Btuh 2.81 Tons (Based On Sensible + Latent) dotes _ T Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition. Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS C:\Users\mrste\Desktop\Shetler Down Stairs\Shetler Upstairs.rh9 Sunday, August 18, 2019, 9:42 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Pioneer Heating&A/C ` Shetler Upstairs Twin Falls, ID 83301 Page 5 Equipment Data - System 1 Cooling System Type: Standard Air Conditioner Outdoor Model: 187BNA036*0**B* Indoor Model: CNPV*4221AL* Tradename: EVOLUTION SERIES AC 2-STAGE Outdoor Manufacturer: BRYANT HEATING AND COOLING SYSTEMS AHRI Reference No.: 9395803 Capacity: 36,000 Efficiency: 16 SEER Heating System Type: Natural Gas Furnace Model: 987MA6008OV21 Tradename: BRYANT Manufacturer: BRYANT HEATING & COOLING SYSTEMS Description: Natural Gas or Propane Furnace Capacity: 78,000 Efficiency: 97 AFUE CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS C:\Users\mrste\Desktop\Shetler Down Stairs\Shetler Upstairs.rh9 Sunday, August 18, 2019, 9:42 PM CONfi ACT0 . SHETLE HO FS �' ZONE: R-2 SCALE:I• LOT-334, BLK-I, SETTLERS RIDGE SUBDV. SEWER #: 19639 GENERAL NOTES: STREET., CITY, DAHO WATER #: 9329 HEIGHT. FLOOR HEIGHT 15"MIN.ABOVE CURB LOT SIZE: 29,143 SF 2. ALL WORK PERFORMED SHALL MEET CODE COMPLIANCE: 2012 IRC CURRENT ADOPTED CODES OF NEW CONSTRUCTION mm CCONFDLICTINNGILDING NOTES,DTIHE MORE SE OF SINGLE FAMILY DWELLING ^w STRINGENT REQUIREMENT SHALL MAIN FLOOR = 2,168 APPLY). 3. VERIFY ALL UTILITIES BEFORE DIGGING, SECOND FOOR = 1,113 (DIG LINE DIAL 811 OR I-SOO-342-1525 ATTACHED GARAGE = 2,143 4. SITE AND STRUCTURE SHALL BE KEPT COVERED PATIO AREA = 1,100 SF CLEAN.SUBCONTRACTOR TO VERIFY ALL DIMENSION.IN CASE OF ERRORS OR DISCREPANCIES ENFR(xY NOTE: CONTACT OWNER OR OWNER'S REPRESENTATIVE,BEFORE PROCEEDING.DO NOT SCALE. FOR ENERGY COMPLIANCE USE PRESCRIPTIVE METHODS 5. DO NOT DRAIN-STORM WATER ONTO FOR VENTED CRAW SPACES: ALL PARTS OF THE // ADJACENTLINES LOTS. S, 6. STRING LINES SHALL BE PROVIDED 1, R-30 MIN IN FLOORS HOUSE MUST BE 03 �/ OVER PROPERTY PINS 2, R-20 MIN IN WALLS OUTSIDE OF \�s= ^�i� /6\; AT TIME OF IN5PECTION5. 3, R-35 MIN IN ATTIC SPACES OVER LIVING AREAS EASEMENTS, \< -N� 4-35 MIN LOUD-E WINDOWS INCLUDING FOR CONDITIONED CRAWL SPACES: 5O' MIN. FOOTINGS I. R-19 MIN AT FOUNDATION PERIMETER \�`b \, CANYON RIM 2. R-20 MIN IN WALLS ' \ SETBACK. TO BE 3. R-38 MIN IN ATTIC SPACES OVER LIVING AREAS 4. 35 MIN LOW-E WINDOWS DETERMINED BY MAX HEIGHT OF HOUSE FOR BASEMENTS R-13 MIN a BASEMENT WALLS LEE GLAESEMANN TO BE 25'AT 50'FROM DO NOT DRAIN STORM WATE IF CLOSE CANYON RIM AND SHEET SCHEDULE: ONTO ADJACENT LOTS �Py� ^„ 100'FR M RIM.P TO HOUSE Al - COVER SHEET, SITE PLAN CA FROM RIM. HOUSE o�a,,o ��� CANNOT BE ANY CLOSE A2 - FOUNDATION PLAN oQ� THAN THIS TO RIM A3 - FLOOR PLAN, FRAMING NOTES AND DETAILS y�o� A4 - SECOND FLOOR PLAN FQ A5 - SECOND FLOOR ROOF PLAN $ �'�• A& - FIRST FLOOR ROOF PLAN / FLOOR JOIST PLAN �, \ SLOPE GRADE AWAY AT - ELEVATIONS \\ FROM FND. 6" IN 10' MIN. AO - ELEVATIONS FINAL GRADING TO BE SLOPE GRADE AWAY pooA FROM FND. io" IN 10' MIN. MAINTAINED AFTER NORTH FINAL GRADING TO SE LANDSCAPING MAINTAINED AFTER LANDSCAPING C) s� DRAINAGE WATER Off ' \ o USE BEST MANAGEMENT PRACTICE FFE 15"ABOVE 2 < I RETENTION AREA �� ;-�,_6„ TO CURB MIN 1 s� TO RETAIN 0_F3_OF STORM AS NECESSARY �� . . . i old, WATER ON PROPERTY Do NOT RAIN STORM b ELEVATI N AT 39% IMPERVIOUS 6 ---_ I •\ 0 WATER INTO ADJACENT LOTS ai FF 15 — ---__ z BERMS / SWALE TO 5E o \ o ELEVATION AT MAINTAINED CURB 0'-m' uz jI \'\ w s w AFTER FINAL INSPECTION 039 \ a W z 4 a— \ N Q UA L_ \ �\ y w 1 0 \ (s) W m � w co \ � W w SOLID SURFACE w m DRIVE _ \ N W 2322 o U N N 3„ \ ffO o > 1 BISBEE PLACE 7'S ° 3,- m •B'MAN ------ 0 pl- Ol NI.9"ON3 \\ N� A VMV 30V21S 3d0IS 5� a STRING LINES TO BE PROVIDED OVER 90 PROPERTY PINS AT TIME OF INSPECTION b rua s m DO NOT DRAIN STORM WATER 0 . ONTO ADJACENT LOTS e„ CITY APPROVED PLANS PAG PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS H #: lilLaj E. APOR REDAROER HAVING �OR'IANGE RATING OF ID OR LESS I,'GYP BD TYP FINISH VINYL SIDING OVER 085 �5 WRAPED AS SHEAR WALL MIN.R-20 INSULATION Te OM FLOORING 2X6®Ib'- i947•5 Gl'9•Ib'O.G. �@ 2-P.T.SILL PLATE 1 D- C-1 C-1 6•X 24'CONCRETE FOMDATION WALL •4 RE VE BAR RT.4'O.C. MIN-•4 REBAR OR T- F53.25 r - F53.0 Q 2X4 PONY WALL a 16'OC. \ \ W/P7,PLATE ,ry.9 / 7HI TO R-30 2 �10J 1 2'-Ou MI 12' a FC3.25 \ \ HD-1 EXCAVATIO : Ill,reba 24"BELOW FROST is zxL d DEPTH MIN. 1 ()CONT F4 BARB ?8PKIb'FOOTING 24' (2)CONT°4 BARS VISQUEEN nin. ,nih �r C-2 IN b'XIb'FOOTING IN GRAWLSPAGE ena aisto.n x. F .D •y (7rP) 52.0 - 11_411 I1_ ,Jn C-1 I �'F C-2 a C-2 TYP FOOTING DETAIL INSULATED FLOOR 1. - r- ----- - - - - - - - N.T.S. L VERIFY ALL FOOTINGS, TIE C-32.5 - _ DOWNS, FRAMING, AND SHEAR 1/2'DRYWALL FS3.7 ,� 2.4 STUDS m 16'O.C. 6 WITH ENGINEERING SPECS R-13INSULATION UD111 2 6C LU N - l/16'O.S.B.SHEATHING - r - - - - - - - - - RRIER BEFORE BEGINNING ANY WORK. VINYLORAPOR ETAL.H VINYL OR METAL HORIZONTAL SIDING 1 - - r I 2X4 P.T.SILL PLATE / I ID-9 W 1/2'DIA ANCHOR BOLT 4'O.G. - - - - - - - - - - - - - T T - - - - - SIM SON 12 ATTACHED TO COLUMN CONSTRUCTED OF(6)2X6 4'CONCRETE FLRV. / , \ 6'X 24'CONCRETE FOUNDATION WALL /' \ •4 REBAR VERT.4'O.G. / \ 30'CLEAR BELOW FLOOR J015TS MIN.OVER DIG COMPACTED GRAVEL III --I 14 2-"4 REBAR VERT,4'O.C. CRAWL AS NEEDED ABOVE UNDISTUFI EARTI-r / \ °,' -III • • f FOOTING REBAR HORZ. C-2 1 CzARAGE WALL DETAIL B I\ / I♦ II I I \ / I I HD- A CHEDTO COLUMN CONSTRUCTED WITH(6)2%6 Dd S FOUNDATION NOTES: O OL 0- ,�',�' \\\\ \^ LU C ED IT z -__-_ • D9 I. VERIFY BOTH GARAGE DOOR BLOCK OUT SIZE m u. w Q \ \ / I r - WITH MANUFACTURER/SUPPLIER. Q Lu Lu � - - 2. PROVIDE EXPANSION JOINTS IN ALL FLATWORK p O Q AS NECESSARY. d k-2 - F54.0 3. ALL FLAT WORK TO BE 4' ./- ABOVE COMPACTED w w 7 GRAVEL SLOPE g"PER 12"TO GARAGE DOORS OR AWAY FROM FOUNDATION WALLS. _ Q IV- 4. ALL SINGLE STORY FOUNDATION WALLS TO BE y 11 FS5.0 MIN.6"X 24'W/(2)"4 BARS SPACED EQUALLY, Lu U RUNNING CONTINUOUS. FOOTINGS ARE 16'X 8'W/ I A w \ \ / 1 (2)"4 BARS RUNNING CONTINUOUS, lu (ll J \\ \\ HD-8 \\ 5. VERTICAL•4 BARS 64'-0'OC,IN STEM WALL AS N w SHOWN IN DETAIL, r ALL FOUNDATION WALLS SHALL BE MIN 3,000•/50 Is) Z \ \ \ \ 1 s SIMPSON STNDI4 STRAPS 1 IN COMPRESSIVE STRENGTH 928 DAYS.ANY w O ~ \\ \\ \\ \\ oR EQu1VALENT 1 PORCHES,PARKING SLABS,STEPS AND GARAGE Q N <D W \ \ PF METHOD '6, \ \ FLOOR SLABS SHALL BE MIN.3,500"/SQ IN W > W \ \ MIN 12'ANCHOR BOLTS 109 \ \ O \ \ MIN T'EMBEDMENT \ \ 1 COMPRESSIVE STRENGTH 9 28 DAYS. z w p p 51MPSON 5TND14 STRAPS a m WASHERS AND NUTS SHALL BE > PF METHOD 7 bXlO'A.B.0 4'0'O.C.MAX.EACH SECTION OF O O p 3 \\ \\ OR EQUIVALENT \ \ INSTALLED ABOVE SOLE f'I=AT-E MIN 12'ANCHOR BOLTS SILL PLATE MUST HAVE MIN.(2)ANCHOR BOLTS. U = Q c0 MIN 7 EMBEDMENT I HD-1 MAX DISTANCE FROM END OF ANY SILL PLATE WASHERS AND NUTS SHALL BE 1 SECTION TO ANCHOR BOLT SHALL BE 12'. INSTALLED ABOVE SOLE PLATE 1 0. PONY WALLS TO BE 2X4 16'O.G.WITH PRESSURE (J Lw _______________ TREATED SILL PLATE,AND DOUBLE TOP PLATE. Z Q I I \\\ S. ROOF/SECOND FLOOR BEARING PONY WALLS p\\ / /' ,e?. ----------------------- TO BE SOLID BLOCKED IF RUNNING PERPENDICULAR TO JOISTS,AND FRAMED TO SUB <12 FLOOR WHEN RUNNING PARALLEL TO JOISTS.\ 10.ANY NAILS THAT PENETRATE CONCRETE OR \ \ \ \ FOUNDATION PLAN NOTES PRESSURE TREAT LUMBER TO BE HOT DIPPED GALVANIZED OR EQUAL. d a E \ \ \ \IMPSON STNDI4 STRAPS ,.0 11. FOUNDATION VENTING,I SQFT/150 SQFT OF CRAWL \\ \ \g U • 1.VERIFY ALL FLOOR OPEINGS FOR MECHANICAL SHAFTS, SPACE WITH VAPOR BARRIER. VENTS MAX 36' � >\ OR EQUIVALENT e , STAIRS,ETC.WITH ARCHITECTURAL AND MECHANICAL FROM EACH CORNER. a M 0 E fta \ \ ` DRAWINGS. 12. PROVIDE CONTINUOUS CRAWLSPACE VAPOR 2.SEE ARCHITECTURAL DRAWINGS FOR COLUMN WALLS AND BARRIER OF 6 MIL VISQUEEN. 0 OPENING DIMENSIONS. 13. COORDINATE EXACT LOCATION OF SIDEWALKS ® M E 3.FIELD VERIFY ALL DIMENSIONS. AND CONCRETE PADS WITH OWNER. 4.ARCHITECT TO VERIFY REQUIRED BEAM CLEARANCE \ \ 5.COORDINATE LOCATION OF DEPRESSED SLABS,SLOPED Z'0 0 SLABS,AND FLOOR DRAINS ARCHITECTURAL AND MECHANICAL DRAWINGS. a '� \ •/ 4 6.SEEARCHITECTURAL AND CIVIL DRAWINGS FOR EXTERIOR CONCRETE WORK AT DOORS,SIDEWALKS,ETC. CITY APPROVED PLANS 7.SEE ARCHITECTURAL DRAWINGS FOR CONTROL JOINT FRAMING PLAN NOTES LOCATION. PAGE #: 8.ALL SPOT FOOTINGS SHALL BE CENTERED UNDER COLUMNS (UNO). 1.VERIFY ALL FLOOR OPENINGS FOR MECHANICAL SHAFTS, 9.SEE DETAIL 7/S-601 FOR TYPICAL CONTROL/CONSTRUCTION STAIRS,ETC.WITH ARCHITECTURAL AND MECHANICAL PLANS MUST BE ON JOB SITE JOINTS IN CONCRETE SLAB ON GRADE. DRAWINGS. lO.SEE DETAIL 5/5-601 FOR SLAB REINFORCING WHERE 2.SEE ARCHITECTURAL DRAWINGS FOR COLUMN WALLS AND OPENING DIMENSIONS. CONTROL JOINTS ARE DISCONTINUOUS. 11.SEE DETAIL 6/S-601 FOR ADDITIONAL REINFORCING AT 3.ALFIELWALLS TO BE DIMENSIONS. E. L/ FOR ALL INSPECTIONS MISCELLANEOUS OPENINGS IN CONCRETE WALLS. 4.ALL BLOCKING 1TEM W LL NOTED ALLC IL 12.SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS FOR ALL S.PROVIDE BLOCKING M TCH WIDTH ALL COILS POINT LOADS TO MATCH WIDTH AND DEPTH OF POST ABV. WALLS AND OPENINGS. 13.ALL WALLS TO BE 2%6 NO.2 STUDS @ 16"O.C.U.N.O. H #: OF E: FIRST FLOOR LIVING AREA 21(o8 salft SECOND FLOOR LIVING AREA 1113 salft RV GARAGE AREA 1205 soft GARAGE AREA 1142 5cgft ENCLOSED COVERED PATIO 4rv3 soft SECOND FLOOR PATIO 463 5CIrt COVERED PORO-4 114 sclft ENERG T' NOTE: GENERAL NOTES: mee vee FOR ENERGY COMPLIANCE USE PRESCRIPTIVE I. DESIGNER ASSUMES NO RESPONSIBILITY FOR METHODS STRUCTURAL INTEGRITY,VERIFY ALL STRUCTURAL ° FOR VENTED CRAW SPACES: SPECIFICATIONS W/MANUFACTURER TRUSS III o° I. R-30 MIN IN FLOORS VENDOR OF ENGINEER. III o ePa 2. R-20 MIN IN WALLS 2. WINDOWS MARKED AS EGRESS SHALL MEET 9 e 3. R-BB MIN IN ATTIC SPACES OVER LIVING AREAS REQUIREMENTS OF THE 2012 IRC.MIN.SIZES= (40'X 4. .35 MIN LOW-E WINDOWS III e � 4a'SINGLE VENT OR SLIDER)(36'X 60'SINGLE FOR CONDITIONED CRAWL SPACES: HUNG)(30'X 46'CASEMENT). III QP ro I. R-19 MIN AT FOUNDATION PERIMETER 3. COORDINATE ALL INTERIOR AND EXTERIOR FINISH, PROVIDE SAFETY Q x 2. R-20 MIN IN WALLS MATERIALS,COLORS,AND QUALITY WITH OWNER GLAZING ON ANY 3. R-38 MIN IN ATTIC SPACES OVER LIVING AREAS 4, COORDINATE KITCHEN DESIGN AND LAYOUT WITH WINDOW WITHIN 36" 2•.9' 3'-6' 3'-b' T-•II G 0' 4. .35 MIN LOW-E WINDOWS OWNER. OF THE PLANE OF THE ��a� FOR BASEMENTS R-13 MIN e BASEMENT WALLS 5. BATH AND RANGE HOOD FANS INDICATED SHALL STAIR WALKING S �pP - -- -�— - - VENT TO OUTSIDE AD MEET ALL REQUIREMENTS OF SURFACE TYP. �° TE p II = THE 2012 IRC.AND BE SMOOTH PIPING WITH MIN 50 e LEGEND 6. VENT DRYER EXHAUST TO DUCT IN WALL AND Ie'-6• 's °5•-a• VENT OUTSIDE. e T. ALL WINDOW AND EXTERIOR DOOR HEADER ARE u �" PosT ,Qp9 O (2)2XIO'S OR EQUIVALENT UNLESS OTHERWISE EGRESS WINDOW SYMBOL NOTED, ti �fc0 E W x 5•PATio DOOR 8. THE UPC REQUIRES A CRAWL SPACE ACCESS ® SMOKE DETECTOR WITHIN 20 FEET OF ALL UNDER FLOOR CLEANOUTS. 5'- °�,° 9. TYP'X'SHEETROCK ON CEILINGS AND WALLS CARBON MONOXIDE DETECTOR BETWEEN GARAGE AND LIVING SPACES INCLUDING BONUS ROOMS. 10.WALL HEIGHTS ABOVE FINISHED FLOOR OF LIVING •�"" 2m MI I.LABLED ® FAN UNIT AREA: SELF LOSING HINGES TEMPERED GLASS 0� FAN 10'-11/5" / SD/ 15x24 MIN CRAWL 5PAGE P,0 ACCE55 REQUIRED WITH N co 20 FT OF ALL TINDER FL�OR (� CLEANOUT5 l��� se � - '-a• 3'-2 mM1me VERIFY ALL FOOTINGS, FIRE CALK ALL � 0� PENETRATIONS FRAMING, AND SHEAR WIT ° ENGINEERING BEFORE ,®e r PROVIDE IMPACT - BEGINNING ANY WORK. (2) ING2X8 LL +. 0 PROTECTION PER (2.2X8 O R a e� IRC CODE .m MIN.AT DOOR � � � - ,rx �0 BEARING WALL m PJQ - m 2m � � �A SD 4_ m z O'�0 Smoke Detector location: a w z 2 m a Smoke alarms and smoke detectors shall not be installed o o within a 36"horizontal path from the supply register of a N w 0 >� BEARING WA m forced air heating or cooling system and shall be installed wF � 0 FIRE CALK ALL die mry° outside of the direct airflow from those registers. o f PENETRATIONS e Y ff -3. J 0 a'e. PROVIDE IMPAC a@ J LU Ln tim PROTECTION PER Ln m ym IRC CODE MIN.LABLED w F cLo5ING HINGE5 y m �P� '__ a Smoke Detector location: N N -------- - --------------------------- s o Go Smoke alarms and smoke detectors shall not be o W ° o installed within 36"horizontal path from the tip of 0 N N W the blades of ceiling suspended fan. z o m em�e °0 > > e o 73/4"RISE MAX Smoke alarms shall be at least 3' �y IN 0 -----o � � _ 10"MIN.RUN away from bathroom doorway, unlessZ� � a. 3/4"-11/4"NOSING< this would prevent placement of a m e m 1'18� 11"TREAD DEPTHsmoke alarm required by NFPA 72 C x Ia•oERHeAD DooR 6'-8"MIN.HEADROOM------ --------------------------- FROM NOSING For tray—shaped ceilings (coffered ceilings), 0 HANDRAIL34"-38" smoke alarms and smoke detectors shall be installed on the highest portion of the ceiling a s or on the sloped portion of the ceiling within uu, e m a 12" vertically down from the highest point. a M e E mrym ° FIRE CALK ALL Please reference NFPA 72 Chapter 29.vv 0 '0 PENETRATIONS S i E-------------' IN 36'LANDING c r----------- m w m £= R315.1 Carbon monoxide alarms. For new Q r construction, an approved carbon monoxide ¢� � alarm shall be installed outside of each separate a W o� sleeping area in the immediate vicinity of the Vo �w I,+° m nirNPR� bedrooms in dwelling units within which fuel—fired appliances are installed and in dwelling units that have attached garages.v PAGE # MIN.(pJN 2x4 NAILER ALONG LL CITY APPROVED PLANS �9 ?. NFPA (Chapter 29) Smoke alarms shall not be installed in the X u 1-R'STAIR following locations unless this would prevent placement of a STRINGER smoke alarm. PLANS MUST BE ON JOB SITE 1*Ionization smoke alarms shall not be installed less than 20' horizontally from a permanently installed cooking appliance. MIN 36'LANDING 2.1onization smoke alarms with an alarm silencing switch shall not be installed less than 10'horizontally from a permanently FOR ALL INSPECTIONS v installed cooking appliance. 3.Photoelectric smoke alarms shall not be installed less than H STAIR DETAIL 6'horizontally from a permanently installed cooking appliance. OF N.iS. E. Smoke alarms shall be at least T away from bathroom doorway,unless this would prevent placement of a smoke alarm required by NFPA 72 PRE ENGINEERED SLOPING FLAT TPolSSE9 PARAPET WALL RUBBER MEMBRANE ROOF OVER I.OSB Smoke Detector location: a Smoke alarms and smoke detectors shall not be R-38 IN CxENERAL NOTES: SUL.MIN. 11'-Im�• ,,,-,}, installed within 36"horizontal path from the tip of the blades of ceiling-suspended fan. 1. WALL HiE1r HTa: C TILE ER TRLLSEE6 STEEL BEAR BY OTHERS Smoke Detector location: \ 101-1 Iva° Smoke alarms and smoke detectors shall not be installed DETAIL ® 12'-1 11V within a 3611 horizontal path from the supply register of a " \ 1rz'DRYWALL SEE PmsT 2-STUD$+I6'O.C.FIRST FLOOR forced air heating or cooling system and shall be installed R-10 MIN INSULATION •i4 O 0 T/16'OSF.SHEATHING outside of the direct airflow from those registers. p�` _ SIDING —E OSB DECKING /J GLUED AND NAILED II UB'60D0 SERIES BCI'9 I6'OL. 3 6 y�Q STEEL POST Y W �G 4 @ W SE EDT LS I p� IB'- . - STEEL BEAM BY OTHERS LVL A STEEL BRACE 9 1'-S' 1, 4'-4'me 4'-4' 1, 4'-4' 1, 1'-S' IR'DRYWALL 3x6 STUDS+16'OC.FIRST FLOOR R-10 MIN INSULATION J''TIG OSS DECKING LJED AND NAILED BIDING II_6000 SERIES ECI'S Ib'OL. STEEL �Oe E DET 6I bM I 36"GUARD MI . 4,6 / SD/ cc %� me / III 9LOPIIJG FLATTTRIBSES PARAPET WALL `BBER MEMBRANE ROOF OVER R-38 INSUL.MIN. / J�'C� 4y� CANTILEVER TRUSSES h o R �pc� STEEL BEAM BY OTHERS / - Q I mP� Irz'DRYWALL 1x6 SCUDS a I6'O.G.FIRST FLOOR y J R-20 MIN INSULATION T/16'OSB.SHEATHING SIDING e T O DECKING 6 S GLUES D AND D NAILED 000 SERIES BCI'S I6.OL. m� FAN Q FAN + O STEEL BEAM—OTHERS 3-I 3/4'X II t/e'LVL n �' OI6T5 IL 0 0 o✓ _ DRYWALL Pl �- 0 ENDS a 16'OL.FIRST FLOOR R-10 MIN INSULATION W LU 7/16'OSB,SHEATHING J'TKa OSB DECKING J - BIDING GLUED AND NAILED Q W Z 3 c.> n lre•6mmm sERIEs BGrs Ib•oL. Q 0 Q 7 Lu 13 DEVIL 82 N W ui N W 9 F ID z 9 F W x \ \ SLOPING FLAT—SES Q W j W PARAPET WALL RIBBER MEMBRANE ROOF OVER O J F OSB 0 0 O m cn \ u � QN En \ \ CANTILEVER TRISSEB \ / STEEL BEAM BY OTHERS p \ �' In'DRYWALL � 0 x\ 3x6 STUDS+I6'O.G.FIRST FLOOR [d3 R-]0 MIN INSULATION a E 11,6.OSB.BREATHING a u SIDING Io �} \ \ 3'TAG ILI AN NG b a E GLED AND NAILED @ II t/e'6000 SERIES BCI'S 16'O.C. � �� rt�E STEEL BEAM BY OTHERS @ i II]'JOISTS @� U1 \ / CITY APPROVED PLANS P'DRYWALL `/ 6 6TID5+Ib'OL.FIRST FLOOR PAGE #: R-10 MIN INSULATION j•TW OSB DECKING l/I6'OSB.SHEATHING GLUED AND NAILED PLANS MUST BE ON JOB SITE B'°'"� 000 SERIES BCI66.OL. FOR ALL INSPECTIONS 74 .4 DETAIL 53 H OF E. BM-2 C-2 C-2 SIMPSON MSTC66-18 STRAP i BM-2 aw J - I SW-2 SW-4 I I I � I I I I I I I I � I I I i m C-3 � SIMPSON MST37-24 STRAP I I I � I I I I i I � I I � c SW-2 •y 3' I I I � c9r'a, SI SON C66-1 TRAP G ER RUsS I a STRA UST GN WI JOIST C-2 �T AND PUN RIM LTOB OM GIST a nLL I - ' '"z d 4 n ' o I I N � I n O I � e � I I I _ ESO GIRDER 5s —SIMPSON MST37-24 STRAP ,,, 0 0 Z LIJ [L LL Q W d W W 6 W U Lu<N W lz ILI 9> O SFS w m SIMPSON MST60 STRAP w r m O Z H U LLI I K U w > F W (e O }_ () U Q n I I \ 5W-3 7V M I p � es g SW-4 HD-6 SW-3 HD-6 <{ � \ SIMPSON MST60 STRAP \ 9 SIMPSON HST3 STRAP � feat 0E NJ (99 5 / b / J PAGE #: CITY APPROVED PLANS PLANS MUST BE ON JOB SITE 45 FOR ALL INSPECTIONS SHEEI #: E: , GOOF FFAI INCH NOTES: D D W°u Wnll 127 - Top Plnte 2 - Top Plnte I, TRUSS DESIGN AND LAYOUT SHALL BE PROVIDED AT FRAMING INSPECTION. 2. PROVIDE MEANS TO RESIST UPLIFT AT EACH LOCATION SHOWfJ ON TRUSS DESIGN DETAILS. 3. PROVIDE COLLAR TIES FOR HAND FRAMED ROOF RAFTERS. Prod°ets en"ee o"tr,e sn"e 4. COORDINATE EXACT LOCATION OF ATTIC ACCESS WITH msto.11 dingo"°tly.sons s;de of the wml p"°�ded they AVAILABLE HEADROOM IN ATTIC ABOVE HATCH. PROVIDE MIN min nunn2z truss.enr °"P°O"�'9°red ns sh°"". 30'HEADROOM ABOVE HATCH PER 2012 IRC. 5. GARAGE TRUSSES TO BE DESIGNED TO: D 30" TOP CHORD LIVE LOAD wnu 128 Top Plnte 1 TOP CHORD DEAD LOAD 10" BOTTOM CHORD DEAD LOAD 3 eO MPH WIND 6. HOUSE TRUSSES TO BE DESIGNED TO: &0" TOP CHORD LIVE LOAD 100 o DURATION 15" TOP CHORD DEAD LOAD 10° BOTTOM CHORD DEAD LOAD III BM-5 _ 90 MPH WIND H2.5T 3V III - BM-4 III Nnili"g into both sides of single III ply oo truss"I thew d to spelt. III SJSPENDE.CpJCFE:TE I I III BM-1 III BM-4 OR EQ Tll 110 —O.C. ZD III OR EQUNELENT BM-1 SW-5 F� PosT s-}• II�•LVL � � ---------- Strong-Dl,!v rl ' TRUSS Screw SDWC15600 BM-4 SWA s B c F' SW-5 SW-1 s II I II e Z N 'i \ O w LU lY ® 0 Q Z O SW-4 p 0 (Lu 0 a N W LL 9 I 15 N O O II lz 10 BM-5 i i L`BM 5 W C) W U,I HD-6 _ _ _ _ —__—_L_ _ _ N m W SW-6 W O ZO H BM-6 N W U N O O Q m U 7 Q 0 I � g SW-3 -- `.I Q I xr-m• ° g'/12 SLOPING FLAT TPo155E5 IN i I UJ 6 i i ♦ � i 0 HD-6 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS H OF E: , DWG To PDF.pc3 (01 e e e ------------------------------ a i--------------------------------- --------------- ---- --------------------------------------------------- ----------- - " ---------------------------------------- F 171 FRI ------------------------------------------------------------------------ ------------ ----------- --------- ------------------------------------------------------------------ e 000 ® ® DODO 00 0 ® ® DODO -7 00 0 � ® DODO 00 0 ---- --------------- --- --- -------------------------- DODO FIRONT ELEVATION 35' MAX HEIGHT OF BUILDING Buildings shall have approved address numbers,or approved building Identification placed All buildings shall have a permanently posted address,which shall be placed at each driveway entrance and be visible from both directions of travel along the road.Buildings shall have approved e address numbers,or approved building Identification placed in a position that is plainly legible,visible = m z from the street or frontage road fronting the property and of a contrasting color(IFC 505.1). = o Address size is based on distance from the street:up to 50 ft.is 4 in.,51 to 100 ft.is 6 in., 101 to 150 0- `n � z ft.is 8 in., 151 to 200 ft.is 10 in.and greater is 12 in a w w 0 p o q W > N W 'D JJ_I 0 _C1 —A _ ff W LLI J O I m N W .. O N J Z ______________________________ O W --- a W w ------- --- ----------------------------------------- ----------------------J o W ° °m ______________________________ U 0 1 N ----------------------------- �� x ----------------- ----------------------------- " C ZZ Z --- -- ------ ------------------El 11 M �p �E 011 ftd S1 M T c T c✓di — =iro B PAGE #: -- -------- — A 7 ------ ------------ PLANS MUST BE ON JOB SITE f;RE,4f;,:' ELEVATION FOR ALL INSPECTIONS H OF E. ---------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ ------------------ --------- ----- 0 0 0 ------------------------------------- 00 0� 00 00 RIGS J SIDE ELEVATION e -------- ---------------------- ---------------------------- ---- ------ ----------------------------, — Z a o ° 4 W > N w 'D W 0 _C1 -A _ ff W Y O w LU 2 m L L N w LLI--------- - Q ----------------- W _ ---------------------- ---------------------------- ---- ----- ---------- w > ------- ----------- ------------------ ------------------------------------------------------------------------------------ � o m 0 U 7 Q N ZnEn �o 0 � a --------------------- ---- ---- ------- Llf'ti JII LEFT SIDE ELEVATION IF _VW W Buildings shall have approved address numbers, or approved building Identification placed CITY APPROVED PLANS All buildings shall have a permanently posted address, which shall be placed at each PAGE # driveway entrance and be visible from both directions of travel along the road. Buildings shall have approved address numbers, or approved building Identification placed in a PLANS MUST BE ON JOB SITE position that is plainly legible, visible from the street or frontage road fronting the property and of a contrasting color (IFC 505.1). Address size is based on distance from the street: up to 50 ft. is 4 in., 51 to 100 ft. FOR ALL INSPECTIONS is 6 in., 101 to 150 ft. is 8 in., 151 to 200 ft. is 10 in. and greater is 12 in H # OF E. 1 2 3 4 5 C-1 C-1 CLIENT -- r-- FS3.0 MARKS AND SYMBOLS LEGEND SHETLER HOMES F53.25 - FS3.25 ---------------- 2183 CANYON TRAIL WAY -------- ------- ------ -------- ------- ------ TWIN FALLS ID III BM-5 SECTION MARK III III - SHEET NUMBER NOESIS ENGINEERING III gM-q HD-1 SERVICES,P.C. I III WH-x INDICATES HEADER TYPE,SEE S-602 III eeBPErroEo CONLIEETE SW-x INDICATES SHEAR WALL TYPE,SEE 5-602 D C-2 III D r F-X_ INDICATES FOOTING AND TOP OF 1 ` III F53.0 TOC_ CONC.FOOTING(TOC),SEE PLAN D BM-1 OR EQUIVELENT @ 1/t�� F52.0 III BMA AND SCHEDULE ON 5-601 C-2 81 rose - III OR EQ 130 12"O.C. - - - C-2 HD-_ HOLD DOWN,SEE SCH ON 5-601 FS5.0 1680 WOODRUFF PARK BM-1 L SW-5 FRAMING PLAN NOTES IDAHO FALLS,IDAHO 83401 RoeT F52.5 (208)932-2720(PHONE) 1. VERIFY ALL FLOOR OPENINGS FOR MECHANICAL SHAFTS, PN 8/7/2019 C-3 B.r B STAIRS,ETC.WITH ARCHITECTURAL AND MECHANICAL BBAwB BY BAi8 -------_---_- DRAWINGS. DB 8/7/2019 2. SEE ARCHITECTURAL DRAWINGS FOR COLUMN WALLS AND REVIBBr FS3.75 II OPENING DIMENSIONS. DS 8/7/2019 3. FIELD VERIFYALL DIMENSIONS. E E 4. ALLWALLSTO BE SW-1 UNLESS NOTED OTHERWISE. TECHNICALAPPR-L ME HD-7 (2)2X6 COLUMN7 i / 5. PROVIDE BLOCKING IN STEM WALL BELOW ALL COLS AND POINT LOADS TO MATCH WIDTH AND DEPTH OF POST ABV. 13. ALLWALLSTO BE2X6 NO.2 STUDS@ 16"D.C.U.N.O. I III FOUNDATION PLAN NOTES W~ 7~ ECHANICAL SHAFTS, ii BM`\ SIMPSON HD12 ATTACHED TO COLUMN CONSTRUCTED OF(6)2X6 1. VERIFY ALL FLOOR OPEINGS FOR M O STAIRS,ETC.WITH ARCHITECTURAL AND MECHANICAL Q ^ III !TEFL pEAM DY OTJEItl DRAWINGS. 1..1.. SW-4 2. SEE ARCHITECTURAL DRAWINGS FOR COLUMN WALLS AND `• y OPENING DIMENSIONS. LL 8 0 3. FIELD VERIFY ALL DIMENSIONS. Lu Q S' 9 4. CT ARCHITETO VERIFY REQUIRED BEAM CLEARANCE siEEL REAM DY Y/ I B. COORDINATE LOCATION OF DEPRESSED SLABS,SLOPED Lu STABS,AND FLOOR DRAINS ARCHITECTURAL AND z M E HANI ARCHIALDRAWIAND O O J C A �+7✓/ `\\�� II 6. SEE ARCHITECTURAL AND CIVIL DRAWINGS FOR EXTERIOR C CONCRETE WORK AT DOORS,SIDEWALKS,ETC. J - J `\\\`\ 7. SEE ARCHITECTURAL DRAWINGS FOR CONTROL JOINT L� m Q LOCATION. i II 8. ALL SPOT FOOTINGS SHALL BE CENTERED UNDER COLUMNS Z LL \\\\\ c SW-5 (UNO). w n Q /Wv I''L HD-7 - C 1 9. SEE DETAIL 7/S-601 FOR TYPICAL CONTROL/CONSTRUCTION = L�/ z a C-2 III C-1 JOINTS IN CONCRETE SLAB ON GRADE. rn Q - 10. SEE DETAIL S/S-601 FOR SLAB REINFORCING WHERE FS2.5-"�-- FS5.0 FS4.0 - , CONTROL JOINTS ARE DISCONTINUOUS. ti 11. SEE DETAIL 6/S-601 FOR ADDITIONAL REINFORCING AT o SW-1 MISCELLANEOUS OPENINGS IN CONCRETE WALLS. Q O III III - 12. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS FOR ALL J N HD-8 WALLS AND OPENINGS. J LL III y w oIN 14 m HD-9 ATTACHED TO COLUMN CONSTRUCTED WITH(6)2X6 DF A 51MPSON HD 19 CONN ECTE TO _ SVµq COLUMN CONSTRUCTED WITH(6 2X6 HD-9 3 a � AT -2 C_1 FS4.0 BM-5I STEE B v HD-6 eLOTHERB _-___ B FS5.0 a BTEEL EEM1 BT OTERB SW-6 a D-8 BM-6 ., HD-1 I $ SW-3 E l•m sLor ELar rFussEs �S510NAL oFEF �iyF ENGINEERS LIMIT OF SCOPE/LIABILITY E - 1 1 63 I ENGINEER'S DESIGN COVERSTHE FOLLOWING SCOPE,NOTALL 98-1OI1 c ,� TYPICAL DETAILS AND SCHEDULES INCLUDED ARE APPLICABLE TO NF�Op. v <_-- ---------- --i__ __-_- __-� THIS PROJ ECTAND SCOPE: 'flN/ fL B. 1. EXTERIOR TALL WALL GRAVITY AND LATERAL ANALYSIS RESULTING IN SHEAR WALL AND HOLDDOWN A 3 CONSTRUCTIONREQUIREMENTS A a•� 2. EXTERIOR SHEAR WALL AND HOLDDOWN CONSTRUCTION REQUIREMENTS °A � CITY APPROVED PLANS 3. STEEL BEAMS OTEDCO UNLESS OTHERWISE COLUMNS SE NOTED CONTRACTOR SHALL FOLLOW LOCAL i BUILDING CODE,IRC AND TBC PRESCRIPTIVE BUILDING REQU I REMENTS,AS APPLICABLE.ENGINEER'S DESIGN ASSUMES c CONTRACTOR COMPLIANCE WITH THESE APPLICABLE HD-6 PLANS MUST BE ON JOB SITE PRESCRIPTIVE MEASURES. PLAN VIEW 5 a; °¢ �scnLE LOOR MARKUPSLOOR MARKUPS FOR ALL INSPECTIONS SHEET 01 OF 1 2 3 4 5 1 2 3 4 5 CLIENT MARKS AND SYMBOLS LEGEND SHETLER HOMES 2183 CANYON TRAIL WAY TWIN FALLS ID SECTION MARK SHEET NUMBER NOESIS ENGINEERING SERVICES,P.C. WH-x INDICATES HEADER TYPE,SEE S-602 SW-x INDICATES SHEAR WALL TYPE,SEE S-602 F_X_ INDICATES FOOTING AND TOP OF �� 1 D \�\ TOC_ ANDCONC.S FOOTING(TOC6 SEE PLAN D BM-2 1 AND SCHEDULE ON 5-601 6—_E er OTERB HD-_ HOLD DOWN,SEE SCH ON 5-601 C-2 C-2 I 1680 WOODRUFF PARK SIMPSON MSTC66-18 STRAP L PosT BY ID FRAMING PLAN NOTES AHO FALLS, O 83401 BM-2 � (208)932-2720(PHONE) T9� I 1. VERIFY ALL FLOOR OPENINGS FOR MECHANICAL SHAFTS, PN 8/7/2019 .TEAL BEAM BY olE __ _ _ _ I STAIRS,ETC.WITH ARCHITECTURALAND MECHANICAL D6Aw BY M DRAWINGS. DB R oar 8/7/2019 2. SEE ARCHITECTURAL DRAWINGS FOR COLUMN WALLS AND SW-2 SW-4 DSE 8/7/2019E OPENING DIMENSIONS. 3. FIELD ALLSTALL DIMENSIONS. i 4. ALL WALLBTCKINGIO BE SW-1 UNLESSTEMW WALL BELOW ALLC COILS E. TECHNICALAPPI—L ME S. PROVIDE BLOCKING IN STEM WALL BELOW ALL COLS AND POINT LOADS TO MATCH WIDTH AND DEPTH OF POST ABV. 13. ALLWALLSTO BE2X6 NO.2 STUDS@ 16"O.C.U.N.O. "T FOUNDATION PLAN NOTES W Z ' LL STEAL BEAR BY OTERB — H -- -- -------------- 1. VERIFY ALL FLOOR OPEINGS FOR MECHANICAL SHAFTS, O STAIRS,ETC.WITH ARCHITECTURAL AND MECHANICAL \� \ C 3 DRAWINGS. Q. 2. SEE ARCHITECTURAL DRAWINGS FOR COLUMN WALLS AND SIMPSON MST37-24 STRAP I OPENING DIMENSIONS. 3. FIELD VERIFY ALL DIMENSIONS. W 4. ARCHITECTTO VERIFY REQUIRED BEAM CLEARANCE W Q 5. COORDINATE LOCATION OF DEPRESSED SLABS,SLOPED U SLABS,AND FLOOR DRAINS ARCHITECTURAL AND C MECHANICAL ARCHIAND DRAWI O O J C 6. SEE ARCHITECTURAL AND CIVIL DRAWINGS FOR EXTERIOR CONCRETE WORK AT DOORS,SIDEWALKS,ETC. JM J SW-2 I 7. SEE ARCHITECTURAL DRAWINGS FOR CONTROL JOINT W Q Cs,O LOCATION. • I 8. ALL SPOT FOOTINGS SHALL BE CENTERED UNDER COLUMNS Z W LL (UNO). wQMn /�II''''L� 9. 51 $ON TC66-1 TRAP O ER R'J99 9. SEE DETAIL 7/S-601 FOR TYPICAL CONTROL/CONSTRUCTION = "I V I JOINTS IN CONCRETE SLAB ON GRADE. STR UST GN W JOIST (�(') Q C-2 AND PUN RIM D I 10. SEE DETAIL LJOINSAEDI SLAB ONTINUOUS.REINFORCING WHERE `\ LTOB OM OIST M1� i CONTROL JOINTS ARE DISCONTINUOUS. SEE n Ii DETAIL FOR REINFORCING AT R; MISCELLANEOUS OPENINGS INCONCRETE WALLS. OJ N12. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS FORALL WALLS AND OPENINGS. 4 LL Lu O Q J W L4) O / ' GIRDER SIMPSON MST37-24 STRAP m I , j T SIMPSON MST60 STRAP B� I B a \ SW-3 \ w ``\ SW-4 HD-6 SW-3 HD-6 Y ` '^ SIMPSON MST60 STRAP SIMPSON HST35TRAP � E \ I �SSONAL fN �\�GENSFO c�tiF \ J ENGINEERS LIMIT OF SCOPE/LIABILITY EN -1 6 3 0 \`\ ENGINEER'S DESIGN COVERSTHE FOLLOWING SCOPE,NOTALL TYPICAL DETAILS AND SCHEDULES INCLUDED ARE APPLICABLE TO < `rT Q \�\ THIS PROJECT AND SCOPE: -9N� OF 1. EXTERIOR TALL WALL GRAVITY AND LATERAL ANALYSIS RESULTING IN SHEAR WALL AND HOLDDOWN A CONSTRUCTION REQUIREMENTS A 3 2. EXTERIOR SHEAR WALL AND HOLDDOWN CONSTRUCTION > REQUIREMENTS 3. STEEL BEAMS AND COLUMNS CITY APPROVED PLANS UNLESS OTHERWISE NOTED CONTRACTOR SHALL FOLLOW LOCAL BUILDING CODE,IRC AND IBC PRESCRIPTIVE BUILDING REQUI REMENTS,AS APPLICABLE.ENGINEER'S DESIGN ASSUMES CONTRACTOR COMPLIANCE WITH THESE APPLICABLE PLANS MUST BE ON JOB SITE PRESCRIPTIVE MEASURES. PLAN VIEW FOR ALL INSPECTIONS a 2NDEFLOOR MARKUPSNDEFLOOR MARKUPS S-101 SHEET H 1 OF 5 1 2 3 4 5 1 2 3 4 5 CLIENT CONCRETE FOOTING SCHEDULE MAX. SHETLER HOMES REINFORCING CROSSWISE REINFORCING LENGTHWISE DESIGNN LOAD CONCRETE WALL SCHEDULE 2183 CANYON TRAIL WAY DIAGRAM MARK WIDTH LENGTH DEPTH Na. SIZE LENGTH SPACING No. SIZE LENGTH SPACING �T'O'F' HOLDDOWN SCHEDULE TWIN FALLS ID REINFORCING FS1.5 V-6" 1'-6" 10" 2 #4 V0 EQ 2 #4 1'-0' EQ 2,700 LB ALLOWABLE TENSION NES MARK THICKNESS VERTICAL HORIZONTAL TOP AND BOTTOM WALL TYPE COMMENTS FSL75 1'-9" 1'-9.. 10" 2 #4 V-3" EQ 2 pq 1'-3' EQ 3,675 LB MARK HOLDDOWN TYPE FASTENERS NOTE: LOADS PER RANKING CW-6 6" #4 BARS AT I8"O,C. 4 4 BARS AT I6"O.C. (1)#4 BAR 'A' COLUMN SHALLAPPLVFORCE FS2.0 2'-0" T-0" 10" 3 #4 V-6" EQ 3 #4 1'-6' EQ 4,800 LB MANUFACTURER(DF) CW-B 8" #4 BARS AT I8"D.C. #4BARSAT12 O.C. (1)#4 BAR 'A' NOESIS ENGINEERING I NCENTERUNLESS OTHERWISE FS2.25 2'-3" 2'.3" 10" 3 1 I'll EQ 3 #4 111' EQ 6,075 LB HD-1 SIMPSON HOU2-SOR.S CONE•:5/8"O J OR L ANCHOR BOLT,MIN 7"EMBEDMENT 3,075 LBF 20 CW-10 10" #4 BARS AT I6"0.C. #5 BARS AT I5"O.C. (1)#5 BAR 'A' SERVICES,P.C. NOTED FS23 2'1" 2'-6" 10" 3 #4 THU" EQ 3 44 2'-W EQ 7,500 LB WOOD:(6)1/4"X 2 2/2"SIBS(M I N 3"WOOD TH GEN ESS) FS2.75 2'-9" T-9" 10" 3 #4 HD-2 SIMPSON LSTHDB CONE.: HOLODOWN LSTHD8J FOR RIM JOIST 2,230 LBF CD ENDWAL 2'-3" EQ 3 qq 2'-3' EQ 9,075 LB 10 WOOD: 1616d SINKERS W 8"GONE.WALL F53.0 2'-6" 1 1 / 3'-0" 3'-0" 10" 4 JW EQ 2'i' EQ 10800 L8 4 #4 20)16d SINKERS W/8"CONE 1 REINFORCING REINFORCING F53.25 3'-3" 3'-3" 10" 4 p4 2'-9" EQ q #4 2'-9' EQ 12,67518 .WALL HD-3 SIMPSON STHD30 CONE.: HOLDDOWN STHD10J FOR RIM JOIST 3,145_BF®ENDWAL 13 CONCRETE FOUNDATION WALL NOTES: ABBREVIATIONS: \\ 1 D 1. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. E.F. EACH FACE /!>♦ CROSSWISE LENGTHWISE F53.5 3'-6" 3'-6" 10" 4 44 31 EQ 4 44 3'-0' EQ 14,70018 WOOD:( HO-0 SIMPSON$THO14 CONE.: HOLDDOWN $THD141 FOR RIM JOIST 4,210 LBF @ ENDWAL 13 2. CONCRETE FOUNDATION WALLS NOT DESIGNATED ON PLANS SHALL BE REINFORCED AS FOLLOWS: I.F. INSIDE FACE t FS3.75 T-9" 31 10, 5 #4 31 EQ 5 44 T-3" EQ 16,875 LS WOOD:(24)16d SINKERS W/8"GONE.WALL O.F. OUTSIDE FACE "}I FS4.0 4'-0" WHO" 10" 5 #4 T-6" EQ 5 , 3'-0' EQ 19,20D LB HITS SIMPSON HDU4-5052.5 CONC.:5/8"O HEAVY HEX BOLT,MIN 7"EMBEDMENT 4,565 LBF 24 THICKNESS VERTICAL REINFORCING HORIZONTAL REINFORCING )DEPTH FS4.25 4'-3- 4'-3" 10" 5 #4 1..g" EQ 5 44 T-9' EQ 21,6751B WOOD:(10)1/4"X21/2"SDS(MIN 3"WOOD THICKNESS) 6" 94 BARS AT I8"O.C. #4 BARS AT I6"O.C. .I/. 1.... #4 BARS AT 18"O.C. #4 BARS AT 12"O.C. F54.5 4'-6" 4'-6" 12" 5 #5 4'-0" EQ 5 p5 4'-0' EQ 24,3001B HD-6 SIMPSON HDU5-SDS2.5 CONE.:5/8"0 HEAVY HEX BOLT,MIN 12"EMBEDMENT 5,645 LBF 26 30 #4 BARS AT 16"O.C. #5 BARS AT IS"O.C. F54.75 4'-9" 4'-9" 12" 5 #5 4'-3" EQ 5 #5 4'-3' EQ 27,075 L8 WOOD:(14)1/4"X21/2"SDS(MIN 3"WOOD THICKNESS) 1680 WOODRUFF PARK >< FSS.O V-0" 5'-0" 12" 5 #5 4'-6" EQ 5 #5 4'-6' EQ 30,000 LB HD-7 SIMPSON HDUSdD52,5 CONC.:7/8"0 HEAVY HEX BOLT,MIN 12"EMBEDMENT 12' #4 BARS AT 18'O.C.E.F. #4 BARS AT 16'O.C.E.F. FOR FULL LOAD CAPACITY 7,870 LEE 43 IDAHO FALLS,IDAHO 83401 Y``N SN FS5.25 5'-3" 5'.3" 12" 5 #5 4'-9" EQ 5 #5 4'-9' EQ 33,075 L0 WOOD:(20)1/4"X 2 1/2"SDS(MIN 4.5"WOOD THICKNESS) MIN 8"GOING.WALL (208)932-2720(PHONE) `NXD FS5.5 V-6" 5'4" 12" 5 #5 5'1" EQ 5 #5 51-V EQ 36,300 LB 110-8 SIMPSON HDUll-SDS2.5 CONE,: 1"0 HEAVY HEX BOLT,MIN 18"EMBEDMENT FOR FULL LOAD CAPACITY 11,175 LBF 05 WALL REINFORCING PLACEMENT TYPES: N< -u 1� PIN 7/23/2018 WOOD:(30)1/4"X21/2"SIBS(MIN 7.25"WOOD THICKNESS) MIN B"GONG.WALL F55.75 5'-9" 5'-9" 14" 6 MS 5'-3" EQ 6 p5 5'-3' EQ 39,675 LB 4 oRAw er oAre FS6.0 6'-0" 6'-0" 14" 6 #5 51-V EQ 6 #5 5'-6' EQ 43,200 LB HD-9 SIMPSON HDUI4-SDS2.5 LONG: HEAVY HEX ANCHOR NUT IN HOLDDOWN KIT 14,445 LBF 51 DB R 7/23/201E WODD:(36)1/4"X21/2"SDS(MIN 7.25"WOOD THICKNESS) 4 Dssweo er 7/23/2018 VERTICAL VERTICAL REINFORCING REINFORCING WALL(OR COLUMN)SHALL FC3.3 V-4" CONT 8" 1 #4 1'-0" 12"D.C. 2 44 CONT EQ 1,800 LB/FT HORIZONTAL HORIZONTAL APPLY FORCE IN CENTER FELS V-6" CONT 8" 1 #5 1'-2" 12"D.C. 2 p4 CONT EQ 2,000 LB/FT NOTES: REINFORCING REINFORCING UNLESS OTHERWISE NOTED FC1.75 V-9" CONT 8" 1 1 #5 V-3" 12"D.C. 2 44 CONT EQ 2,400 LB/FT 1. ALLOWABLE LOADS HAVE BEEN INCREASED FOR EARTHQUAKE OR WIND LOAD DURATIONS WITH NO FURTHER INCREASE ALLOWED.REDUCE WHERE FC2.0 2'-0" CONT 8" 1 05 1'-6" 12"O.C. 2 #4 CONT EQ 2,7001B/FT OTHER LOADS GOVERN. REINFORCING 2. USE ALL MANUFACTURER SPECIFIED FASTENERS. W z REINFORCING FC2.25 2'r CONT 10" 1 #5 1'4' 12"O.C. 2 " CONE EQ 3,000 LB/F7 3, SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. IL CROSSWISE LENGTHWISE FC2.5 2'-6" CONT 10" 1 #5 2'-0" 12"O.C. 2 #4 CONT EQ 3,300 LB/FT 4. SOME SCHEDULED HOLDDOWNS MAY NOT BE USED,SEE FOOTING AND FOUNDATION PLAN FOR HOLDDOWN MARKS. 11/2" O .1' FC2,75 T-9" CONT 10" 1 #5 2'-3" 12"D.C. 2 " CONT EQ 3,700 LB/FT 5. I N FORMATION PROVI DIED H ERE 15 DESIGN ED BY N ES AND MAY ON LY BE USED BY PERM ISSION. c- a IDEPTH FC3.0 3'-0" CONT 12" 1 Jt5 2'-6" 12"O.C. 2 44 CONT EQ 4,000 LB/FT 6. TH IS SCH EDO LE WAS ADOPTED AS PART OF NES STAN DARDS IN JULY 2018,FU ILL CALCU LATION PACKAG E ON FILE IN N ES MAIN OFFICE. TYPEW TYPE'B' TYPE'C' TYPED' / } FC3.25 T-3" CONT 12" 1 #5 2'-9" 12"D.C. 2 p4 CONT EQ 4,300LB/FT (z�HOLDDOWNSCHEDULE FC3.5 T-6" CONT 12" 1 #s TEO' 12"O.C. 2 #4 CONT EQ 4,600WET s-6o1 r3�CONC.WALL SCHEDULE LL !t-4,6'N �. �J 5-601 /Y, w Q BAR AT CORNER U C TO MATCH VERT WALL ` O O J REINFORCING :,. CONTROLOR C CONCRETE FOOTING NOTES: ° .. _ J (2)#4 x 4'-0"BAR$AT EACH CORNER CONSTRUCTION JOINT 1. COMPRESSIVE STRENGTHS OF CONCRETE AT 28 DAYS SHALL BE 3,000 P51 - Y CO Q 2. PLACE ALL FOOTING REINFORCING IN THE BOTTOM OF THE FOOTING WITH 3"CLEAR CONCRETE COVER(UNO). (2)BARS AT INTER. OF DEPRESSED SLAB WHERE .. __ Z �f w L� 3. TOP REINFORCING,WHERE OCCURS,SHALL BE PLACED INTHETOP OFTHE FOOTING WITH 2"MINIMUM CONCRETE COVER. TO MATCH VERT CONTROL/CONSTRUCTION JOINTS DO a,2 _ �l WALL REINFORCING NOT EXTEND FROM CORNER //I��T Z 4. IF FOOTINGS EARTH-FORMED,FOOTINGS SHALL BE fi"LONGER AND WIDER THAN SCHEDULED. � ,, -t = (17 V a 5. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. (Y') Q m 6. SOME SCHEDULED FOOTINGS MAY NOT BE USED,SEE FOOTING AND FOUNDATION PLAN FOR FOOTING MARKS. - DEPRESSED CONCRETE (n CORNER BAR(S) _,4 i'4 fd 7. THIS SCHEDULE ASSUMES A SOIL BEARING PRESSUREOF I,5DO ESE 4_.": a` SLAB .Ii S. INFORMATION PROVIDED HERE IS DESIGNED BY NES AND MAY ONLY BE USED BY PERMISSION. 9. THIS SCHEDULE WAS ADOPTED AS PARTOF NESSTANDARDS IN JULY2018,FULLCALCULATION PACKAGEON FILE IN NES MAIN OFFICE. Q O V) �i�CONC.FOOTING SCHEDULE (2)#4x4'-0"BARS WHERE Q LJL 5-601 N JOINTS CONCRETE WALL, CTERSEC/BUT DO NOT CONTINUE CONCRETE NOTES SEE PLAN AND SCHEDULE INTERSECT BUT DO NOT CONTINUE _ BEYOND INTERSECTION ��. 1. MATERIALS,UNLESS NOTEDOTHERWISE: A. NORM AL WEIGHT AGGREGATES ASTM 03 w B. REINFORCEDSTEEL ASTM A615 GRADE60(FY=60 KSL) f CONTROL OR N USE GRADE 40(FY-40 KSL)FOR BENT DOWELS WITH BAR AT INTERSECTION ° CONSTRUCTION JOINTS SPACING INDICATED REDUCED BY 1/3, TO MATCH VERT WALL O CONCRETE WALL,SEE C. DEFORMED BAR ANCHORS IDEA) ASTM A496 PLAN AND SCHEDULE REINFORCING (2)#4x4'-D"BARSWHERE 3 i D. HEADED STUD ANCHORS(NSA ASTM A308 CONTROL/CONSTRUCTION JOINTS E. ANCHOR RODS ASTM F1554 GRADE 36 WITH ASTM A563 HEAVY HEX STEEL COLUMN,SEE PLAN NUTS WITH HARDENED WASHERS DO NOT EXTEND FROM CORNERS m F. ADMIXTURES: BEND NORMALWALL REINFORCING - - OF CONCRETE BLOCKOUTSAT - AND SCHEDULE m I. AIR-ENTRAINING ADMIXTURES COMPLY WITH ASTM C260(WHEN USED). OR PROVIDE BAR OF SAME II. CALCIUM CHLORIDE SHALL NOT BE ADDED TO THE CONCRETE MIX. BUILDING COLUMNS G. TYPE/II CEMENT COMPLYING WITH ASTM C150 SHALL BE USED FOR ALL CONCRETE. SIZE AND SPACING WITH LAP CORNERBAR 3 H. THE WATER/CEMENT RATIOS SHALL MEET THE REQUIREMENTS OF ACI 318. ASPER GENERAL STRUCTURAL I. PROVIDE AIR ENTRAINING AS RECOMMENDED BYACI 318, NOTES,TYPICAL I J. NOALUMI HUM CONDUITOR PRODUCT CONTAINING ALUMINUM ORANYOTHE MATERIAL INJURIOUS TO CONCRETE SHALL BE (2)BARSATCORNER CONCRETE BLOCKOUT O0 EMBEDDED IN CONCRETE. TO MATCH VERT WALL -' 2. COMPRESSIVE STRENGTHS OF CONCRETE AT 28 DAYS SHALL BE AS FOLLOWS:AT REINFORCING A. FOOTINGS 3,000 P51 - B. INTERIORSLABSON GRADE 3,000 PSI �s�LOCATION REQUIRING ADDITIONAL SLAB REINFORCING B B C. WALLS 3,000 PSI 5-601 D. ALL SITE CONCRETE 4,000 PSI 3. ONLY ONE GRADE OR TYPE OF CONCRETE SHALL BE POURED ON THE SITE AT ANY GIVEN TIME. 4. THECONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN,DETAILING,CARE PLACEMENT AND REMOVAL OF ALL FORM WORK AND SHORING. CORNER BARS A. SUPPORTING FORMS AND SHORING SHALL NOT BE REMOVED UNTILSTRUCTURAL MEMBERS HAVE ACQUIRED SUFFICIENT STRENGTH TO CONCRETE WALLS SAFELY SUPPORTTHEIR OWN WEIGHT AND ANY CONSTRUCTION LOADTOWHICHTHEY MAYBESUBIECTED.IN NO CASE,HOWEVER, 4 SHALLFORMS AND SHORING BE REMOVED IN LESS THAN 24 HOURS AFTER CONCRETE PLACEMENT. 5. REINFORCEMENT SHALL HAVE THE FOLLOWING CONCRETE COVER: 4 TYP.CORNER WALL REINFORCING EDGE EACH SIDE OF CASTAN-PLACE CONCRETE: CLEAR COVER 5-601 JOINT WITH 1/8"RADIUS A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" CONCRETE SLAB ON _ B. FORMED CONCRETE EXPOSED TO EARTH OR WEATHER: GRADE,SEE PLAN #6 THRU#18 CARS 2" #5 AND SMALLER BARS 1_1 .. USE STANDARD HOOKS Y C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACTWITH GROUND: TRIM BARS: WHERE FULL EMBEDMENT BA MS, OLLMNS:PR#11BAR5AND SMALLER 1-1/ ° •° _ - ° BEAMS,COLUMNS:PRIMARY REINF.TIES,STIRRUPS,SPIRALS 1-1/2" 6"-8"WALLS (2)#5 BARS(EXTEND 4'-0"MIN BEYOND EDGE OF OPENING) IS NOT POSSIBLE 6. CONSTRUCTION101NTS AND CONTROL JOINTS: 30"42"WALLS-(2)#6 BARS(EXTEND 4'-0'MIN BEYOND EDGE OF OPENING) WHERE JAMB IS LESS THAN A. PROVIDE A FORMED AND BEVELED 2x4x CONTINUOUS KEYWAY IN ALL HORIZONTALAND VERTICAL CONSTRUCTION JOINTS,UNLESS T-0",PROVIDE#3 TIES AT U NOTED OTHERWISE.IN ADDITION,ALL JOINTS SHALL BE INTENTIONALLY ROUGHENED TO A FULL AMPLITUDE OF APPROXIMATELY 1/4". 8"OC o B. CONTROL JOINTS SHALL BE INSTALLED IN SLABS ON GRADE SO THE LENGTH TO WIDTH RATIO OF THE SLAB IS NO MORE THAN 1.25:1. III=III=�= =�=III i CONTROL101NTS SHALL BE COMPLETED WITHIN 12 HOURS OF CONCRETE PLACEMENT.CONTROL JOINTS MAYBE INSTALLED BY: TRIM BARS TRIM BARS w I. SAW CUT A DEPTH OF 1/4 THE THICKNESS OF THE SLAB TRIM BARS SLOPE=1:3 ij II. TOOLED JOINTSA DEPTH OF I/4 THE THICKNESS OF THE SLAB 015t 4"MIN.3/4"CRUSHED $ C. INSTALL CONSTRUCTION OR CONTROL JOINTS IN SLABS ON GRADE AT A SPACING NOTTO EXCEED 30 TIMES THE SLAB THICKNESS IN ANV `'� COMPACTED STRUCTURAL FILL GRAVEL COMPACTED DIRECTION FOR UN-REINFORCED SLABS AND 75 TIMES THE SLAB THICKNESS IN ANY DIRECTION FOR REINFORCED SLABS UNLESS NOTED ♦� OR COMPETENT UNDISTURBED TO 95%OF MODIFIED - - _ , - - CONSTRUCTION JOINT OTHERWISE.CONSTRURION JOINTS SHALL NOT EXCEED A DISTANCE OF 125'-0"O.C.IN ANY DIRECTION. NATIVE SOIL PROCTOR(ASTM-D1557) N 7. CONSTRUCTION Q.2 >' - 5510 A(�- E N o A. PSE LACING PSOROTHERSUPPORTSHAL DEVICES INRECOMMENDED USLYSUPORTD CRSITOS.MAXI UM TIE REINFORCING BARS AND WWFON PRIOR TO e;' ° , _ G n v PLACINGCONCRETE.WWF SHALL BECONTINUOUSLVSUPPORTED AT 36"O.C.MAXIMUM.REINFORCING STEEL FOR SLABS ON GRADE CONCRETE SLAB ON a CHALL BE ONCRETE 15 NOT SUPPORTED ON PRECAST CONCRETE UNITS.LIFTING THE REINFORCING OFF THE GRADE DURING PLACEMENTOF ::: ,-.. : ,- `>. GRADE SEE PLAN WITHIN FIRST 12 HOURS CONCRETE IS NOT PERMANENT. '4 OF SLAB POUR � 1 630 <a, g ry B. CONCRETE TO BE MECHANICALLVCONSOLIDATED DURING PLACEMENT PER ACI STANDARDS. , .,, ,� - "' '� ''.-- �.�'�: �� - F C. CON TRACTOR SHALL COORDINATE PLACEMENT OF ALL OPENINGS,CURBS,DOWELS,SLEEVES,CONDUITS,BOLTS,INSERTS AND OTHER ' '•"^' a 4 I' EMBEDDED ITEMSPRIORTO CONCRETE PLACEMENT. ?..,'°•a'"_ "-."�k.� - .. fT Q .a.9... O 9 P - D. ALLEMBEDSAND DOWELS SHALL BE SECURELY TIED TO FORM WORK OR TO ADJACENT REINFORCING PRIOR TO THE PLACEMENTOF D 9 Tf OF� P CONCRETE. N - / S v OR f - E. NOTPIPES,LENGI ETC. REPLACES N STRUCTURAL HENAPPROVCONCRETE SHALL B BUILTSPECIFICALLYNTOTHETAILE PRIOR T CONCRETE �'<•�:."."�.:',.:�-.: OPEN ._�,«:.,,�-,:�_. OPEN 'y _ - OPEN ( B STRUCTURAL PENETRAR.TIONS WALL NOT BE ALLOWED WALLS WHEN APPROVED SHALL RE BUILT D TO THE WALL IPING SHALL L BE ROUTED 4- _ PLACEMENT.PENETRATIONS WILL NOT BE ALLOWED IN FOOTINGS OR GRADE BEAMS UNLESS DETAILED.PIPING SHALL BE ROUTED A 3 AROUND THESE ELEMENTS AND FOOTINGS STEPPED TO AVOID PIPING. A F. REINFORCING BARS SHALL NOT BE WELDED.DO NOT SUBSTITUTE REINFORCING BARS FOR DBAS OR HSAS. 0 8. DETAILING: - ��� - 4'MIN.3/4"CRUSHED z °- COMPACTED STRUCTURAL FILL OPEN ;''.' D i A. LAP LENGTHS SHALL BE AS FOLLOWS: "._ '� -• :_,:.. GRAVEL COMPACTED w I. 30 BAR DIAMETERS FOR#3 AND#4 BARS OR COMPETENT NDISTURBED CONTROL101NT U TO95%OF MODIFIED II. 00 BAR DIAMETERS FOR pS THROUGH pB BARS NATIVE SOIL PROCTOR(ASTM-D1557) o -..... .� .s:a i III. DO NOT SPLICE STIRRUPS AND TIES. IV. DO NOT SPLICE VERTICAL BARS IN RETAINING WALL UNLESS SPECIFICALLY SHOWN. - _ OPEN B. ATJOINTS PROVIDE REINFORCING DOWELSTO MATCH THE MEMBER REINFORCING,UNLESS NOTED OTHERWISE. _ ���TYP SLAB ON GRADE JOINT DETAIL C. AT ALL DISCONTINUOUS CONTROL OR CONSTRUCTION SLAB ON GRADE JOINTS,PROVIDE 2-k4x48". -601 5 D. PROVIDE CORNER BARS AT INTERSECTING WALL CORNERS USING THE SAME BAR SIZE AND SPACING AS THE HIRIZONTAL WALL �`.d.; • + _ CONCRETE.SCHEDULES i REINFORCING. "4"• _ �; E. ALLVERTICALREINFORCING SHALL FOR EDOWENT AO FOOTINGS,OR VE.DOELSETO THE ENDIGI NTOFOTINGRE WWITH THE RMINAT SIZE ITHA SPACING AS ' THE VERT! REINFORCING FOR THE ELEMENT ABOVE.DOWELS EXTENDING INTO FOOTINGS SHALL TERMINATE WITH A90 DEGREE CITY APPROVED PLANS STANDARD HOOK AND SHALL EXTEND TO WITHIN 4"OF THE BOTTOM OF THE FOOTING.FOOTING DOWELS(#8 BARS AND SMALLER)WITH HOOKS NEED NOT EXTEND MORE THAN 20"INTO FOOTINGS. SINGLE OPENING SIDE-BY-SIDE OPENINGS STACKED OPENINGS S-601 '^ F. HO IZONTAL WALL REINFORCING SHALL TERMINATE AT ENDS OF WALLS AND OPENINGS INTO THE FAR END OF THE JAMB COLUMN WITH �1 PLANS MUST BE ON JOB SITE c¢ A90 DEGREE STANDARD HOOK PLUS A 6 BAR DIAMETEREXTENSION.HORIZONTAL WALL REINFORCING SHALL BE CONTINUOUS THROUGH 6 TYP REINFORCING FOR MISC OPENING IN CONC WALLS LESS THAN 3' SHEET#3OF5 CONSTRUCTION AND CONTROL101NTS. S_�1 1 2 3 4 FOR ALL INSPECTIONS 1 2 3 4 5 CLIENT SHETLER HOMES MINIMUM NAILING SCHEDULE SHEATHING SCHEDULE AT ROOF AND FLOOR 2183 CANYON TRAIL WAY HEADER BEARING SCHEDULE FOR 2x STUD WALL TWIN FALLS ID LOCATION CONNECTION NAILING WOOD SHEATHING NAIL EDGE NAIL FIELD BOUNDARY EDGE SOLE PLATE TO JOIST OR BLOCKING,FACE NAIL 16d AT 16"O.C. THICKNESS SIZE ONT EDG THER EDG NAIL NAIL BLOCK COMMENTS MAXIMUM JAMB MARK HEADER COMMENTS BRIDGING TO JOIST,TOENAIL EACH END (2)8d ROOF 7/16"24/0 8d GIN 1 121N SIN NO HEADERSPAN BEARING STUDS KING STUDS BLOCKING BETWEEN JOIST OR RAFTERS TO TOP PLATE,TOENAIL (3)8d FLOOR 23/32"OSB(48/24) 10d GIN I GIN 12 IN 61N NO WH-1 (2)2X10 OR 5.5"X9.5"LVL --- (1)2X6 (1)2X6 NOESIS ENGINEERING RIM JOIST TO TOP PLATE,TOENAIL 8d AT 6"O.C. WH-2 (3)2X100R 5.5"X9.5"LVL --- (1)2X6 (1)2X6 SERVICES, COLLAR TIE TO RAFTER,FACE NAIL (3)10d SHEATHING NOTES: WH-3 (3)2X12 OR 5.5"X9.5"LVL --- (2)2X6 (2)2X6 JACK RAFTER TO HIP,TOE NAIL (3)10d 1. MINIMUM NAIL PENETRATION INTO FTAMING:8d-1 1/2",lOd-15/8". FACE NAIL (2)16d 2. USE COMMON NAILS(Sd DIAMETER=0.131",10d DIAMETER=0.148". wHa (2)13/4X11]/8"LVL --- (212X6 (3)zx6 1 ROOF RAFTER TO 2x RIDGE BEAM,TOE NAIL (2)16d 3. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. FACE NAIL (2)16d D JOIST TO BAND JOIST,FACE NAIL (3)16d D LEDGER STRIP,FACE NAIL (3)16d NOTE:MEMBER SIZES SHOWN ARE MINIMUM DEPTHSAND WIDTHS TOP PLATE TO STUD,END NAIL (2)16d CENTER EDGES OF SHEATHING.STAGGER 8"GAP AT END JOINTS 2x WALL STUDS,TYP DOUBLE STUDS,FACE NAIL l6d AT 24"D.C. PLYWOOD ON JOISTS JOINTS AN D ALTERNATE KING STUD(S) DOUBLED TOP PLATES,FACE NAIL l6d AT 16"D.C. AND BLOCKS GRAIN DIRECTIONS LEDGER 2x CONT PLATE TOP PLATES,LAPS&INTERSECTION,FACE NAIL (2)16d 1680 WOODRUFF PARK CONTINUOUS HEADER,TWO PIECES l6d AT 16"O.C.ALONG EACH EDGE 2 IDAHO FALLS,IDAHO 83401 CEILING JOISTS TO PLATE,TOE NAIL (3)8d CONTINUOUS HEADER TO STUD,TOENAIL (4)8d 0 (208)932-2720(PHONE) CEILING JOISTS,LAPS OVER PARTITIONS,FACE NAIL (3)16d ,n PN 7/23/2018 CEILING JOISTS TO PARALLEL RAFTERS,FACE NAIL (3)16d a TI o8nw er onre RAFTER TO PLATE,TOENAIL (3)8d a WALL(WHERE (4)16d NAI EACH DB R DeY onr 7/23/2018 1"BRACE TO EACH STUD&PLATE,FACE NAIL (2)8d OCCURS),SEE END OF ADER SECTION e BUILT-UP CORNER STUDS l6d AT 24"O.0 PLAN CISe 7/23/2018 BUILT-UP GIRDER&BEAMS 20d AT 32"O.C.AT TOP,BOTTOM, WOOD HEADER.(3)2x's AND STAGGERED.(2)20d AT ENDS WITH 1/2"FILLER AND AT EACH SPLICE. EDGE NAIL CONTINUOUS PLYWOOD&PARTICLEBOARD: EDGE(WHEN BLOCKING SIMPSON'ACE6'POST SUBFLOOR,ROOF&WALL SHEATHING(TO FRAMING)* IS REQUIRED) CAP.FILL ALL HOLES WITH 16d NAILS 19/3AND LESS 8d EDGE NAIL,OTHER TRIM STUD(S) z Lu 19/32"-3/4" 8d OR lOd 7/8"-1" 8d EDGE O 11/8"-11/4" 8d OR 10d FIELD NAILING S�s�WOOD HEADER SCHEDULE COMBINATION SUBROOR-UNDERLAYMENT(TO FRAMING)' 3/4"AND LESS 6d 7/8"-1" 8d rI - 11/8"-11/4" 8dORSOd EDGE BLOCKING WHERE BOUNDARY NAIL W Q REQ'D,LAY FLAT(UNO) Y W SHEATHING SCHEDULE AT ROOF AND FLOOR ® O o J C `NAILS SPACED AT 6"O.C.AT EDGES,12"O.C.AT INTERMEDIATE SUPPORTS(EXCEPT WHERE SPANS ARE 48"OR 5-602 J EL- J C MORE,THEN SPACE AT 6"O.C.AT SUPPORTS).FOR NAILING OF DIAPHRAGMS AND SHEAR WALLS,REFER TO Y coQ SHEARWALL SCHEDULE. DOUBLE 2x IN 6"STUD WALL Z LLj IL = mLDZ a MINIMUM NAILING NOTES: rn Q 1. NAILING SCHEDULE IS PER TABLE 2304.10.1 OF THE I.B.C.2015. L m 2. NAILING REQUIREMENTS SHOWN HERE DO NOT REPLACE HARDWARE SHOWN ON r L 3. THE PLANS OR DETAILS. O V)16d NAILS AT 12"O.C. Q I- 4. ALL NAILS USED ARE COMMON NAILS. J 5. SEE G EA SIDE-STAGGERED ENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. 16d NAILS AT I2"O.I J W MINIMUM NAILING SCHEDULE DOUBLE 2. TRIPLE 2. EA SIDE-STAGGEREI J 5-602 WOOD SHEATHING SHEARWALL SCHEDULE WALLFRAMING WALLSHEATHING 12 12" w MARK TOP BOTTOM STUD& FASTENER FASTENER COMMENTS (n STUDS BOTTOM PLATE ANCHORS BLOCK AT THICKNESS EDGE NAIL FIELD NAIL PLATE PLATE JOINTS TYPE SIZE o OSW-1 2.6 AT 16'O.C. (2)2x6 2.6 5/8"0 A.B.AT 48"O.C. 2. 7/16" STAPLES 1 1/2"16P 6"O.C. 12"O.C. NOTE 8 r SW-2 2x6 AT 16"D.C. (2)2x6 2x6 5/8"�A.B.AT 48"O.C. 2x 7/16" NAILS 8d 6"D.C. 12"D.C. NOTE8 1/2"0 THRU-BOLT AT 3 24"O.C.-STAGGERED SW-3 2x6 AT 16"D.C. (2)2x6 2.6 5/8"0 A.B.AT 48'O.C. 2. 7/16" NAILS 8d 4"O.C. 12"O.C. NOTE8 a SW4 2x6 AT 16"D.C. (2)2x6 2x6 5/8"0 A.B.AT 48"D.C. 2x 7/16" NAILS 8d 3"D.C. 12"D.C. I NOTE8 QUADRUPLE 2x 3 SW-5 2x6 AT 16"D.C. (2)2x6 2x6 5/8"0 A.B.AT 48"O.C. (2)Zx 7/16" NAILS 8d 2"D.C. 12"D.C. NOTE8 SW-6 2x6 AT 16"D.C. (2)2x6 2x6 5/8"0 A.B.AT 48"D.C. (2)2x (2)7/16" NAILS 8d 3"D.C. 12"D.C. NOTE8 wooD SHEATHING SHEARWALL NOTES: / 5__)MINIMUM NAILING SCHEDULE 5-602 3 GENERAL NOTES 1. PROVIDE 3/16"x2"x0'-2"WASHER PLATES AT BOLTS. A 2. WHERE CALLED FOR ON SCHEDULE,USE COMMON NAILS.GALVANIZED NAILS SHALL BE HOT-DIPPED OR TUMBLED. 1. TYPICAL DETAILS AND SECTIONS SHALL APPLY WHERE SPECIFIC DETAILS ARE NOT SHOWN. 3. ANCHOR BOLTS SHALL HAVE A 7"MINIMUM EMBEDMENT INTO CONCRETE AND TERMINATE WITH A 3"STANDARD 90°HOOK. B 2. THECONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS.IFACTUAL 4, WHERE STUDS ARE CUT FOR PLACEMENT OF ANCHOR BOLTS OR OTHER ELEMENTS,AN ADJACENT STUD SHALL BE ADDED. B CONDI HALLI MEDIANS FEL FROM THOSE SHOWN GINEER EFOEPROCTHE CTDRAWIITHTTHE CONTRACTOR 5. WHERE WOOD SHEATHING IS APPLIED TO BOTH SIDES OF A WALL AND NAIL SPACING IS LESS THAN 6"D.C.ON EITHER SIDE,PANELIOINTS SHALL BEOFFSET TO FALL ON DIFFERENT SHALL IMMEDIATELY NOTIFY THE ENGINEER BEFORE PROCEEDING WITH THE FABRICATION OR CONSTRUCTION OF ANY EFFECTED ELEMENTS. FRAMING MEMBERS,OR FRAMING MEMBER SHALL BE 3"OR THICKER AND NAILS ON EITHER SIDE SHALL BE STAGGERED. 3. THE CONTRACTOR SHALL SUBMIT A WRITTEN REQUESTTO THE ENGINEER BEFORE PROCEEDING 6. PRE-DRILLED HOLES ARE REQUIRED AT 20d NAILS. 4'-O"MINIMUM LAP WITHANYCHANGES,SUBSTITUTIONS OR MODIFICATIONS.ANY WORK DONE BVTHE ]. SEE GENERAL STRUCTURAL NOTES FOR ADDITIONAL REQUIREMENTS. CONTRACTOR BEFORE RECEIVING WRITTEN APPROVAL WILL BEAT THE RISK OF THE SPLICE BOTTOM PL Q CONTRACTOR. 8. ALLWOOD SHEAR WALLS GREATER THAN I6'TALL SHALL HAVE ALL PANEL EDGED BLOCKED AND NAILED AT EDGE NAILSPACING OVER STUD 4. IN CASE OF A CONFLICT BETWEEN THE CONTRACT DRAWINGS AND THE SPECIFICATIONS, FOLLOW THE MOST STRINGENT REQUIREMENT OR DIRECTIONS PROVIDED BY THE ENGINEER AT TOP PLATE SPLICE NO ADDITIONAL COST TO THE OWNER. _ 5. THE CONTRACTOR SHALL COORDINATE WITH ALLTRADES ANY ITEMS THATARE TO BE INTEGRATED IN THE STRUCTURAL SYSTEM SUCH AS OPENINGS,PENETRATIONS,MECHANICAL, EDGE NAILING,TYP ELECTRICAL EQUIPMENT,ETC.SIZES AND LOCATIONS OF MECHANICAL AND OTHER EQUIPMENT w WOOD WALL SHEATHING THAT DIFFERS FROM THOSE SHOWN ON THE CONTRACT DRAWINGS SHALL BE REPORTED TO THE ENGINEER. FIELD NAILING,TVP ALTERNATE DIRECTION OF 6. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING AS REQUIRED FOR HIS WOOD GRAINS.AT METHOD OF ERECTION. CONTRATOR'S OPTION, ]. SHORING AND BRACING SHALL REMAIN IN PLACE UNTIL FINAL CONNECTIONS FOR THE BLOCKING.BLOCK PERMANENT MEMBERS ARE COMPLETED.THE BUILDING SHALL NOT BE CONSIDERED STABLE ALLJOINTS SHEATHING MAY BE t UNTIL ALL CONNECTIONS ARE COMPLETED. INSTALLED VERTICALLY (2)16d AT 4"D.C. 8. WALLS SHALL NOT BE CONSIDERED SELF-SUPPORTING AND SHALL BE BRACED UNTIL THE FLOOR/ROOF SYSTEM 15 COMPLETED. ¢ ((24)16d MIN EA o SIDE OF EA SPLICE) 3 WOOD NOTES _ JOINTSTUD 1. MATERIALS: DNA L A.FRAMING LUMBER SHALL BE IF 1-2DOUGLAS FIR-LARCH OR BETTER UNLESS NOTED ON STUDDAND BLOCKS OOD SS GENS FN� OTHERWISE; WALLSTUDS B.WOOD SHEATHING SHALL BE INTERIOR GRADE WITH GLUE,SPAN INDEX RATIO,UNLESS OTHERWISE NOTED. a 24/0 WALLS 48/24 ROOF 'I 'I HOEDOWN WHERE 6 3 O E C.NAILS:STANDARD COMMON WITH THE FOLLOWINGPROPERTIES: OCCURS IN L SIZE SHANK DIAMETER MIN.PENETRATION INTO SUPPORT MEMBER WOOD SILL(ANCHOR BOLTS TYPICAL WALL STUDS fT9-d-NJI Q _ SO FLOORSLABOR AND NAILINGNOTSHOWN) 9/f or SD 0.131" 1.50" FOUNDATION WALL "9i(/ �. 1oD o.14a" 1.63" /f( m 12D 0.141' 1.63" w T D 0.162" 1.75" fASTENERS OTHER THAN COMMON NAILS ARE NOT PERMITTED WITHOUT PRIOR WRITTEN A 3 APPROVAL FROM THE ENGINEER. A D.BOLTS SHALL BE ASTM A360R EQUAL WITH ASTM A563 HEAVY HEX NUTS AND HARDENED WASHERS,GRADE A,UNLESS NOTED OTHERWISE. 1/R"GAP AT END JOINTS E.ALL LAMINATED VENEER LUMBER(LVQ SHALL BE FURNISHED BY TRES-JOIST CORPORATION OR VERSA-LAM BY BOISE CASCADE CORPORATION. 2. ALL WOOD IN BE DWOOpCONTACT WITH CONCRETE,MASONRY OR SOIL SHALL BE PRESSURE TREATED OR �WOODSHEATHINGSHEARWALLSCHEDULE 3. GENERAL FRAMING AND CARPENTRY SHALL BE CONNECTED AS PER"UNLESS NOTED 5-602 4- 0 HERWISE.MINIMUM NAILING SCHEDULE. c 4 ALL BYSIMP OINSTRONG-TIEOR NG ANCHORS, SAP RPOVEDED A DOWN S,COLUMN BASES,ETC.SHALL BEPROVIDED 6 TOP PLATE SPLICE 5 5. BUILT-UP BEAMS OF2X-MEMBER 12 IN.OR LESS IN DEPTH SHALL BE SPIKED TOGETHER WITH 5-602 WOOD SCHEDULES NOT LESS THAN 16-D SPIKES AT TWELVE-INCHES(12 IN.)CENTERS,STAGGERED.IF THE DEPTH OF BEAM IS MORE THAN TWELVE INCHES(12 IN.),THE MEMBERS SHALL BE CONNECTED TOGETHER �a WITH 3/,"0 BOLTS @24IN.O.C.STAGGERED.BOLTS SHALL BE PLACED Y°"THE DEPTH OFTHE CITY APPROVED PLANS MEMBER FROM THE TOP AND BOTTOM OF THE MEMBER. io 6. ALLWALLSSHALL HAVE A MINIMUM OF TWO TOP PLATES.SPLICES IN TOP PLATES SHALL BE STAGGERED A MINIMUM OF FOUR FEET FROM THE NEAREST SPLICE IN ADJOINING TOP PLATE. 5-602 ]. ROUGH SAWN LUMBER BEAMS AND POSTSTO BE SOUTHERN PINE NO.1 DENSE SR - PLANS MUST BE ON JOB SITE SHEET JJ40F 5 1 2 3 1 4 FOR ALL INSPECTIONS 1 2 3 4 5 CLIENT STEEL NOTES SHETLER HOMES 2183 CANYON TRAIL WAY TWIN FALLS ID 1. MATERIAL: A. WIDE FLANGES SECTION ASTM A992(50 KSI) NOESIS ENGINEERING B. OTHER SHAPES&PLATES ASTM A36 SERVICES,P.C. C. PIPE COLUMNS ASTM A53,TYPES E OR S,GRADE B. D. STEEL TUBES ASTM A500 GRADE 46KSI NOTE: EA TO Y BOLT PLATEOLE WITH A CONTIN ALIGN,UOUS FIELD ( ) WELD BEAM TO CAP PLATE WITH A CONTINUOUS E. DEFORMED BAR ANCHORS(DBA) ASTM A496 1/4"FILLETWELD ON BOTH SIDES. <> D F. HEADED STUD ANCHORS(HSA) ASTM A108 �`,/� D G. BOLTED CONNECTIONS: ASTM A325 2. FABRICATION AND CONSTRUCTION SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS: a. AMERICAN INSTITUTE OF STEEL CONSTRUCTION(AISC),"SPECIFICATION FOR THE DESIGN,FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS,"WITH"COMMENTARY". 1680 WOODRUFF PARK b. AISC"CODE OF STANDARD PRACTICE"EXCLUDING THE FOLLOWING:SECTION 3.4,SECTION 4.4,SECTION 4.4.1, IDAHO FALLS,IDAHO 83401 C. AISC"SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" (208)932-2720(PHONE) d. AMERICAN WELDING SOCIETY(AWS),STRUCTURAL WELDING CODE(SPECIFIC ITEMS DO NOT APPLY WHEN THEY CONFLICT WITH THE AISC 3-SIDES PNNw er 7/23/2018 REQUIREMENTS). DB 7/23/2018 e. AISC"SEISMIC PROVISION FOR STRUCTURAL STEEL BUILDINGS " @CONTINUOUS BEAM @ BEAM END pS­ DATE 7/23/2018 3. WELDING BEAM WEB SIFFENER OR BEAM WEB TECHNICALA—L ME a. ALL WELDING AND CUTTING SHALL BE PERFORMED BY AWS CERTIFIED WELDERS. CONNECTION PL ATE,EACH SIDE b. USE E-70 XX OR AS NOTED OTHERWISE. C. ALL INTERSECTING STEEL SHAPES WHICH ARE NOT BOLTED SHALL BE CONNECTED BY A FILLET WELD ALL AROUND,UNLESS NOTED OTHERWISE. WHERE FILLET WELD SIZES ARE NOT SHOWN THEY SHALL BE 1/16"LESS THAN THE THINNEST OF THE CONNECTED PARTS FOR ® LLI z THICKNESSES 1/4"AND LARGER. FILLET WELDS ON PLATES LESS THAN 1/4"SHALL BE OF THE SAME SIZE AS THE THINNEST OF THE ® LL CONNECTED PART. ® Q O d. DO NOT WELD ANCHOR BOLTS,INCLUDING "TACK"WELDS. W 4. BOLTED CONNECTIONS: = a. USE ASTM A325N BOLTS FOR STEEL TO STEEL CONNECTIONS,AS NOTED HEREIN OR AS NOTED ON THE DRAWINGS.A325N BOLTS SHALL BE W STEEL BEAM,SEE PLAN Y w 0 USED IN CONNECTIONS FOR SIMPLE SPAN FRAMING AND BEAM(OR GIRDER)TO BEARING PLATE CONNECTIONS.TIGHTEN BOLTS TO A V Z SNUG TIGHT CONDITION. N O O —.1C b. USE HARDENED WASHERS BENEATH THE TURNED ELEMENT OF ALL BOLTS OR NUTS. USE HARDENED BEVELED WASHERS,TO J J C COMPENSATE FOR THE LACK OF PARALLELISM,WHERE THE OUTER FACE OF THE BOLTED PARTS HAS A SLOPE GREATER THAN ONE IN STEEL BEAM,SEE PLAN Y cod Q TWENTY WITH RESPECT TO THE PLANE NORMAL TO THE BOLT AXIS.AT OVERSIZED HOLES HARDENED WASHERS OR PLATES SHALL SEE PLAN Z Q LW LL• CONFORM WITH ASTM F-436 AND SHALL COMPLETELY COVER THE SLOT AFTER INSTALLATION. STEEL CAP PLATE,SEE COL = (Y) 0 z C. WHERE A STEEL TO STEEL BEAM CONNECTION IS NOT SHOWN,PROVIDE A STANDARD AISC FRAMED CONNECTION FOR ONE HALF THE 1/4 SCHEDULE M 0 TOTAL UNIFORM LOAD CAPACITY OF THE BEAM FOR THE SPAN AND STEEL SPECIFIED. STEELCOLUMN,SEE PLAN AND D. BOLTS,NUTS AND WASHERS SHALL NOT BE REUSED. SCHEDULE �i Q O N 5. PROVIDE FULL-DEPTH WEB-STIFFENER PLATES AT EACH SIDE OF ALL BEAMS AT ALL BEARING POINTS.STIFFENER PLATES SHALL BE THE THICKNESS J = CALLED OUT BELOW UNLESS NOTED OTHERWISE AND SHALL BE WELDED BOTH SIDES WITH FILLET WELDS ALL AROUND: Q J FLANGE WIDTH STIFFENER THICKNESS WELD SIZE LESS THAN 81/4" 1/4" 3/16" W 8 1/4"TO 12 1/4" 3/8" 1/4" TYP DROP-IN STEEL BEAM CONNECTION AT STEEL COLUMN N 12 1/4"TO 16 W 1/2" 5/16" 2 16%"TO 20'/<" 5/8" 3/8" 3 3 GENERAL NOTES 1. TYPICAL DETAILS AND SECTIONS SHALL APPLY WHERE SPECIFIC DETAILS ARE NOT SHOWN. B 1 2. THE CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS. IF ACTUAL B CONDITIONS DIFFER FROM THOSE SHOWN IN THE CONTRACT DRAWINGS,THE CONTRACTOR - SHALL IMMEDIATELY NOTIFY THE ENGINEER BEFORE PROCEEDING WITH THE FABRICATION OR STEEL COLUMN AND BEAM SCHEDULE CONSTRUCTION OF ANY EFFECTED ELEMENTS. 3. THE CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST TO THE ENGINEER BEFORE PROCEEDING m WITH ANY CHANGES, SUBSTITUTIONS OR MODIFICATIONS. ANY WORK DONE BY THE CONTRACTOR BEFORE RECEIVING WRITTEN APPROVAL WILL BE AT THE RISK OF THE MARK SHAPE MATERIAL COMMENTS CONTRACTOR. 4. IN CASE OF A CONFLICT BETWEEN THE CONTRACT DRAWINGS AND THE SPECIFICATIONS, FOLLOW THE MOST STRINGENT REQUIREMENT OR DIRECTIONS PROVIDED BY THE ENGINEER AT NO ADDITIONAL COST TO THE OWNER. BM-1 W8X10 A992 5. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES ANY ITEMS THAT ARE TO BE INTEGRATED IN THE STRUCTURAL SYSTEM SUCH AS OPENINGS,PENETRATIONS,MECHANICAL, BM-2 W10X19 A992 ELECTRICAL EQUIPMENT,ETC. SIZES AND LOCATIONS OF MECHANICAL AND OTHER EQUIPMENT THAT DIFFERS FROM THOSE SHOWN ON THE CONTRACT DRAWINGS SHALL BE REPORTED TO BM-3 W12X22 A992 THE ENGINEER. 3 6. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING AS REQUIRED FOR HIS BM 4 W14X34 A992 METHOD OF ERECTION. S$ONAL 7. SHORING AND BRACING SHALL REMAIN IN PLACE UNTIL S FOR THE PERMANENT MEMBERS ARE COMPLETED. THE BUILDING FINAL SHALL NOT BE ON SID RED STABLE BM-5 W18X55 A992 QOF� GENSf19 UNTIL ALL CONNECTIONS ARE COMPLETED. dS E 8. WALLS SHALL NOT BE CONSIDERED SELF-SUPPORTING AND SHALL BE BRACED UNTIL THE BM 6 W18X86 A992 1 1 6 30 FLOOR/ROOF SYSTEM IS COMPLETED. C-1 W4X13 A992 OF fL g, S A d C-2 W5X16 A992 A 3 C-3 W6X20 A992 CITY APPROVED PLANS STEEL SCHEDULES PLANS MUST BE ON JOB SITE S-603 FOR ALL INSPECTIONS SHEET H5OF5 1 2 3 4 Mr.Mike Shetler Lot 33 Block 1 Settlers Ridge August 7, 2019 Mike Shetler Shetler Homes 2183 Canyon Trail Way Twin Falls, ID 83301 Re: Lot 33 Block 1 Settlers Ridge Dear Mr. Mike Shetler: Per your request Noesis Engineering Services (NES) has completed a limited analysis for the residence at Lot 33 Block 1 Settlers Ridge in Twin Falls, ID. Our analysis included the design of the following: • Steel beams and columns • Floor joists • Girders • Steel Beam and columns for the hot tub support • Shear wall design for the residence. Please see markup drawings and design report for design details. If you have any questions, please contact me at (208) 932-2720. Respectfully, 1630 FL B Daniel B. Sharp, P.E. Reviewed By: PN NOESIS ENGINEERING SERVICES, P.C. 1680 Woodruff Park Idaho Falls, ID 83401 Attached: Calculation Report CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Noesis Engineering Services Idaho Falls, ID �1 NOESIS ENGINEERING SERVICES, PC Structural Calculations Lot 33 Block 1 Settlers Ridge — Twin Falls, ID Prepared For: Shetler Homes 10NA[ 11 630 a 09�/EL B S�l� Prepared By: Daniel Sharp, PE CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Noesis Engineering Services Idaho Falls, ID Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El SCOPE: The scope of this design is to analyze the gravity loads(dead, live and snow)and analyze the lateral load (wind and seismic)to design the typical wall studs, king studs,trim studs,shear wall sheeting requirements and moment connections for the tall walls only.Also included are multiple steel beams and columns which will be marked below in this document. This project is located in the city of Twin Falls Idaho, Lot 33A Block 1 of Pioneer point-Settlers Ridge Subdivision DESIGN CRITERIA: International Building Code 2015 (IBC) International Residential Code 2015 (IRC) American Society of Civil Engineers,Standard 7 2010(ASCE-7) Department of Housing and Urban Development, Residentail Structural Design Guide 2000(RSDG) American Wood Council,Special Design Provisions for Wind &Seismic 2015 (SDPWS) National Design Specification for Wood Construction 2015(NDS) APPLIED LOADING&GENERAL INFO: PREENGINEERED FRAMING DLrrass:=5•psf Trusses DL per span, use the reference to Roa Tn the right Structural Wood Design,Jan 2008 sp. sNyw Iptd fA.1 M.1me�1 plr—1 DLIns:=0.07 ps •12•in=0.84 psf Fiberglass per inch,Survey ke in of Local Available Insulation ss Sl 6S DLsheeting:_ 01 ps • 4 in=2.4 psf ASCE7-10 Table C3-1 eu rts /n un v.f 8 f� fas DLroo n :=6.4 psf 110 mil weld down membrane with roof pavers- Per client supplied information DLdrywou:= 0.15 psf' 8 in=2.75 psf Dead load of 5/8 drywal ceiling in 8 DL,heck:=DLrruss+DLins+DLsneeting+DLroofing+DLdrywall=17.39 psf Check must be less than or equal to initial assumption DLR:=18 psf Roof dead load DLw:=12 psf Wall dead load (ASCE 7-10 Table C3-1) DL f:=15 psf Floor dead load LLf:=40 psf Floor live load (IBC Table 1607.1) NOTE: roof live load above accessible roof areas with planned usage shall match floor live loading LLhottub:=150 psf Loading due to hot tub RLL:=20 psf Roof live load (IBC Table 1607.1) SLR:=25 psf Roof snow load Per City of Twin Falls Building department Snow drift calculation Input: pg:=15 psf ground snow r pf:=25 psf flat roof snow D.�w h:=6 ft height projection ° m a 1,,:=46.5 ft length of roof windward (low roof) 1 z:=20 ft length of roof for leeward (upper roof) w Note: lu min=20 ft FIGURE 7.7-2 Conflgursflon of Snowdrft on Lower Roofs CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more Ini Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE \� 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El Is:=1.0 Calculations: �Q y:=0.13•pg+14=15.95 y:=min(y,30)=15.95 pcf Snow density hb:=pf=1.57 ft 60011,Use Now y h,:=h—hb=4.43 ft checks:=if(h` <0.2,"no drift","check drift"1="check drift" hb l leeward .43 g 1.96hd:=(( 3 4 ) ) s = ft hd:=min(0.6•la,hd)=1.96 ft ' �O r windward hd2:=.75•((0.43.3 1i2-4 pg+10)—1.5)• Is =0.83 hd:=max(hd,hd2)=1.96 ft check if wall height is lower than drift heights hd:=if(h,<hd,h,,hd)=1.96 hd:=if(h<hb,0,if(h<(hb+hd),h—hb,hd))=1.96 Drift width 4•hd2 w1:=if hd<h,,4•hd, =7.83 he w:=min(w1,8•hc) ft=8 ft Width of drift pd:=hd-y•psf=31 psf Max drift weight General Information hwaii cau:=16 ft+1 in+ 1 1 in=16.09 ft Height of tallest Wall 8 hpeak:=6 ft Average roof peak height above wall Rrise:= 0 in Typical roof slope or rise per 12 inches of run 12 in WIND: wind:=90 mph Wind Speed (MPH), per Twin Falls Building Design Criteria 1/1/2018 Residential. Increase to 110mph (lowest on ASCE 7-10 figure 28.6-1) Exposure: B Exposure Category, per Twin Falls Building Design Criteria 1/1/2018 Residential h :=2•(10 ft+1 in+ 1 in +1 ff+5 in+2 ft+ hpeak =26.24 ft mean roof height mean ` 8 J 8 2 Lh:=500 ft ASCE 7-10 Figure 26.8-1 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El Hkzt:=3596 ft-3177 ft=419 ft ASCE 7-10 Figure 26.8-1 Hkzt =0.84 >0.5 .'.=0.5 ASCE 7-10 Figure 26.8-1(See footnote 2) Lh K1:=0.43 ASCE 7-10 Figure 26.8-1 Xk,t:=60 ft ASCE 7-10 Figure 26.8-1 distance from peak to building site XkZt =0.07 ASCE 7-10 Figure 26.8-1(See footnote 2) 2•Hkn K2:=0.9832 ASCE 7-10 Figure 26.8-1 Zk,t:=hmean=26.24 ft ASCE 7-10 Figure 26.8-1 Zkzr =0.03 ASCE 7-10 Figure 26.8-1(See footnote 2) 2•Hkn K3:=0.922 Z ASCE 7-10 Figure 26.8-1 K,t:=(1+(K1•K2•K3)) =1.93 ASCE 7-10 Equation 26.8-1 Kd:=0.85 ASCE 7-10 Table 26.6-1 �l:=1 Adjustment Factor for exposure and height,ASCE 7-10 Table 26.6-1 Wind Loading Determination: Angle,00f:=atan(Rrise)=0 deg WLZonec:=12.7 psf Latteral Wind Load on the Wall-ASCE7-10 figure 28.6-1, 110 mpd,0 deg,zone C WLZoneD:=-5.9 psf Latteral Wind Load on the Roof-ASCE7-10 figure 28.6-1, 110 mpd,0 deg,zone D WLZoneH:=-10.1 psf Wind Uplift Load on the Roof-ASCE7-10 figure 28.6-1, 110 mpd,0 deg,zone H Wwoll:=WLZonec-Kn'A=24.53 psf ASCE 7-10 Equation 28.6-1 wall wind pressure Wroof:=WLZoneD-Kzt'A=-11.4 psf ASCE 7-10 Equation 28.6-1 roof latteral wind pressure Wuplift:=WLZoneH-KZt•A=-19.51 psf ASCE 7-10 Equation 28.6-1 roof uplift wind pressure CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El WALL PANEL#1 WALL AND GENERAL SPECIFICATIONS: NOTE: Tall Wall#1 has no walls above it is required to support hwau tali=16.09 ft Height of Tall Wall WALL PANEL-APPLIED FORCE CALCULATIONS: Lateral Loading: Await:=2537 ftz Max area of wall appling wind load to Await walls perpendicular to this tall wall W wall' Pwind'— 2 =15558.53 lbf Combined Point Load for all walls on this side of 2 the building parallel to this tall wall Point Load Applied to the Corner of the Tall Wall: Forceappiied:=Pwind=15558.53 lbf Force Applied to Tall Wall Wwau=25 psf Force Applied to face of Tall Wall Axia Loading: Tribroof:=2 ft Trib length of Roof Trusses appling load on this tall wall DLiinear:=Tribroof'DLR=36 plf Linear Dead Load Applied on Tall Wall RLLiinear:=Tribroof•RLL=40 plf Linear Roof Live Load Applied on Tall Wall SLiinear:=Tribroof•(SLR+pd)=112 plf Linear Snow Load Applied on Tall Wall Wind piift:=Tribroof•Wapiift=-39 plf Linear Wind Uplift Load Applied on Tall Wall MEMBERS-APPLIED FORCE CALCULATIONS: Header 1 Loading: Lheoder:=4.25 ft Design Header length Tribroof=2 ft Trib length of Roof Trusses appling load on this tall wall DLiineor=36 plf Linear Dead Load Applied on Header RLLiineor=40 plf Linear Roof Live Load Applied on Header SLiinear=112.45 plf Linear Snow Load Applied on Header Wind hwau tau •W 197 1 Linear Laterial Wind on Header tat:= wail= Pf 2 King Stud 1 Loading: Tribroof=2 ft Trib length of Roof Trusses appling load on this tall wall Spacingstud5:=16 in Trib length this stud DLpoint:=Tribroof•Spacingstad5'DLR=48 lbf Point Dead Load Applied on King stud RLLpoint:=Tribroof'Spacingstads'RLL=53 lbf Point Roof Live Load Applied on King stud SLpoint:=Tribroof'Spacing,,d5'SLR=67 lbf Point Snow Load Applied on King stud Windiat:=Wwau•Spacingstads=33 lbf Distributed lateral Wind load from wall ft lateral wind load on king stud can cause high deflection,size members for this deflection as well as axial loading. CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE (\� 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El RISA Model of Tall Wall& Header Assembly 123b�� Wall Panel Shear Panel Label Region Shear Check Shear ForcepbAQ Gbv LC Hold-Down Label Chord SUap Label Tension Check Tie-Down Forcepbj S1 706 8da@2 N!A 847 794502 10 H012_55_1_DF-SP r!c 989 14068.09 Member Shape Code Check I Loc[ftj I LC Shear Check ' i • I 2-2X8 .17- 2.125 1; 109 WP-1 WH-4-0 KING 2-2X6 .711 8.045 11 .090 WP-1 WH-4-0 TRIM 2X6 .037 0 7 .000 1NP-1 STUD CHECK 2X6 .557 8.045 11 1 .101 Member Label Span Location[fQ y[in] (n)LYy Ratio LC 1 max 4.029 -.001 INC 9 1 min 2.125 -.009 6908 7 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El WALL PANEL#3: WALL AND GENERAL SPECIFICATIONS: NOTE: Tall Wall#3 has no walls above it is required to support hwau tau=16.09 ft Height of Tall Wall WALL PANEL-APPLIED FORCE CALCULATIONS: Lateral Loading: A,,aii:=2694 ftz Max area of wall appling wind load to walls perpendicular to this tall wall 4 wall W wall' Pwind:— 2 =16521.35 Ibf Combined Point Load for all walls on this side of 2 the building parallel to this tall wall Point Load Applied to the Corner of the Tall Wall: Lp:=100% Percentage of Required Force Applied to the Length of Tall Wall Forceapplied:=Pwind'Lp=16521.35 Ibf Force Applied to Tall Wall Wwau=24.53 psf Force Applied to face of Tall Wall Axia Loading: Tribroof:= 2 2ft Trib length of Roof Trusses appling load on this tall wall DLiinear:=Tribroof'DLR=189 plf Linear Dead Load Applied on Tall Wall RLLiinear:=Tribroof'RLL=210 plf Linear Roof Live Load Applied on Tall Wall SLiinear:=Tribroof•SLR=263 plf Linear Snow Load Applied on Tall Wall Windapiift:=Tribroof•Waplift=-205 plf Linear Wind Uplift Load Applied on Tall Wall MEMBERS-APPLIED FORCE CALCULATIONS: Header 1 Loading: Lheader:=6.25 ft Design Header length Tribroof=10.5 ft Trib length of Roof Trusses appling load on this tall wall DLiinear=189 plf Linear Dead Load Applied on Header RLLiineor=210 plf Linear Roof Live Load Applied on Header SLiinear=262.5 plf Linear Snow Load Applied on Header Windlat:= hwau tau .Wwall= Pf 197 1 Linear Laterial Wind on Header 2 King Stud 1 Loading: Tribroof=10.5 ft Trib length of Roof Trusses appling load on this tall wall Spacingstad5:=16 in Trib length this stud DLpoint:=Tribroof•Spacingstad5'DLR=252 Ibf Point Dead Load Applied on King stud RLLpoint:=Tribroof'Spacingstads'RLL=280 Ibf Point Roof Live Load Applied on King stud SLpoint:=Tribroof'Spacing,,d5'SLR=350 Ibf Point Snow Load Applied on King stud Windiat:=Wwau•Spacingstads=33 lbf Distributed lateral Wind load from wall ft lateral wind load on king stud can cause high deflection,size members for this deflection as well as axial loading. CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El t^tan Panei Snear Panei Label Region Snear Cbeek 9hearForczpbolry GwLC Ho10-Down Label Chore SvaO LaDei Tension Cheu. ire-Down Fore-�;i_. RS_7n6_15G0._112@b N!A 972 21096 10 HDV2-SDS26_DF-SP NC 877 25955F7 U tl v I - O O OVO v OV tI OR.9 OCl Ot➢ O O O O O CD O O OO O Dl Ll Xm O O SDr (D O O tD tD xc-, iD ''r c i o c R3- fV 1 '� X1 CIO co x X COi x+ x xx x x IN,N N CV N NN C, N N N N N N 1 I` I RISA Model of Tall Wall&Header Assembly Member Shape Code Check LocsM LC Shear Check 1 A 2-2X8 .826 3.125 7 .476 7w;v %VH-6 KING 3-2X6 .628 8.045 11 .073 WH-6 TRIM 2X6 .1 Ec 0 7 . 100 STUD CHECK 2X6 .603 8.045 11 .101 z 1971bAt _ Y P 2 rn d x <n rL Member Label Span Location[ft] y[in[ (n)LYy Ratio WA 111 1 max 4.688 .001 NC 1 min 3.125 -.108 728 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El WALL PANEL#4: WALL AND GENERAL SPECIFICATIONS: NOTE: Tall Wall#4 has no walls above it is required to support hwo11:=10.09 ft Height of Wall WALL PANEL-APPLIED FORCE CALCULATIONS: Lateral Loading: A,,oii:=2537 ftz Max area of wall appling wind load to walls perpendicular to this tall wall Await W wall' Pwind:— 2 =15558.53 Ibf Combined Point Load for all walls on this side of 2 the building parallel to this tall wall Point Load Applied to the Corner of the Tall Wall: Lp:=100% Percentage of Required Force Applied to the Length of Tall Wall Forceapplied:=Pwind'Lp=15558.53 Ibf Force Applied to Tall Wall Wwau=24.53 psf Force Applied to face of Tall Wall Axia Loading: Tribfloor:= 17 ft 2 + 2 4.5 ft =10.75 ft Trib length of Roof Trusses appling load on this tall wall DLlinear:=Tribfloor DLf=161 plf Linear Dead Load Applied on Tall Wall LLlineor:=Tribfloor'LLf=430 plf Linear Floor Live Load Applied on Tall Wall MEMBERS-APPLIED FORCE CALCULATIONS: Header 1 Loading: Lheoder:=3.25 ft Design Header length Tribroof=10.5 ft Trib length of Roof Trusses appling load on this tall wall DLlineor=161 plf Linear Dead Load Applied on Header LLlineor=430 plf Linear Live Load Applied on Header Wind lat:= hwan •Wwall= pf 124 1 Linear Laterial Wind on Header 2 King Stud 1 Loading: Tribroof=10.5 ft Trib length of Roof Trusses appling load on this tall wall Spacingstud5:=16 in Trib length this stud DLpoint:=Trib-floor'Spacing,,ds'DLf=215 Ibf Point Dead Load Applied on King stud LLpoint:=Tribfloor'Spacingst ds•LLf=573 Ibf Point Floor Live Load Applied on King stud Windiat:=Wwou•Spacing,,ds=33 lbf Distributed lateral Wind load from wall ft lateral wind load on king stud can cause high deflection,size members for this deflection as well as axial loading. CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El WaOPane1 2 eaf ne_l8� o nSnearcn eck SneFome( GoLC Hold-Dow Label TeftonCheck TiD Ib St78l 7_(2 8 1240.557 10 HDU14-SDS2-5_725DFSP 988W Chord 2-2X6 R2 A H1 ti3 y �OFR Z Y O O O O O O O O H co co to coco R R1 N a m co co co co a X X X X N CV N N G O O C � col ,I N N T. RISA Model of Tall Wall&Header Assembly Member Shape Code Check Loc[fg LC Shear Check 2-2X8 3 4 1.625 5 .371 WP-4 WH-3 KING 2X6 .435 7.042 11 .160 WP-4 WH-3 TRIM 2X6 .113 0 5 .000 WP-4 STUD CHECK 2X6 .222 5.045 11 1 .063 Member Label Span Location[fQ y[in] (n)Uly Ratio LC e • � 1 max 2.573 -.001 NC 19 1 min 1.625 -.013 3971 1 3 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El WALL WALL#5&#6: WALL AND GENERAL SPECIFICATIONS: NOTE: Tall Wall#5 has no walls above it is required to support hwall=10.09 ft Height of Tall Wall WALL PANEL-APPLIED FORCE CALCULATIONS: Lateral Loading: Awalll — ft• hwall+�52.5 � 6 ))=844.73 z Max area of wall appling wind load to walls perpendicular to this tall wall Awollz:=(47 ft•(hwall+6 ft))=756.23 ftz Max area of wall appling wind load to (r walls perpendicular to this tall wall — wwall•II A 2 1I111 Pwindl•— ll Jlll =5180.4 Ibf Shear point load from 1st story at top of 1st of story 2 ��A-.112 wwall 2 Shear point loads from 2nd story one at top of 2nd story Pwindz:= 2 =4637.69 Ibf wall and one at bottom of second story/top of 1st story Point Load Applied to the Corner of the Tall Wall: wwall=24.53 psf Force Applied to face of Tall Wall Axia Loading: Trib 42.5 ft Trib length of Roof Trusses appling load on this tall wall 2 roof:= g pp g Tribfloor:= 12.5 ft2 Trib length of Floor Joists appling load on this tall wall DL,,,:=Tribfloor•DLf=94 plf Linear Dead Load Applied on Tall Wall LL,,,:=Tribfloor•LLf=250 plf Linear Floor Live Load Applied on Tall Wall DL2nd:=Tribr00f•DLR=383 plf Linear Dead Load Applied on Tall Wall RLLznd:=Tribroof•RLL=425 plf Linear Roof Live Load Applied on Tall Wall SLznd:=Tribroof,SLR=531 plf Linear Snow Load Applied on Tall Wall Windznd:=Tribroof•kplifr=-415 plf Linear Wind Uplift Load Applied on Tall Wall MEMBERS-APPLIED FORCE CALCULATIONS: Header 1 Loading: Lheoder:=3.25 ft Design Header length DLznd:=Tribroof•DLR=383 plf Linear Dead Load Applied on Tall Wall RLL2nd:=Tribroof•RLL=425 plf Linear Roof Live Load Applied on Tall Wall SLznd:=Tribroof,SLR=531 plf Linear Snow Load Applied on Tall Wall Windznd:=Tribroof•kplifr=-415 plf Linear Wind Uplift Load Applied on Tall Wall Wind hwall `all •W 197 1 Linear Laterial Wind on Header lat:= wall= P f 2 King Stud 1 Loading: Tribroof=21.25 ft Trib length of Roof Trusses appling load on this tall wall CITY APPROVED PLANS Spacingsrad5:=16 in Trib length this stud PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El DLpoi„t:=Spacingstuds•DL2 d=510 Ibf Point Dead Load Applied on King stud RLLpoinr:=Spacingstuds•RLL2 d=567 Ibf Point Roof Live Load Applied on King stud SLpoi t:=Spacingstuds•SL2d=708 Ibf Point Snow Load Applied on King stud Windipt:=W,,Qii•Spacingstuds=33 Ibf Distributed lateral Wind load from wall ft Stud Check Loading: DLpoi„t:=Spacingstuds•(DL2 d+DL1st)=635 Ibf Point Dead Load Applied on stud check LLpoi„t:=Spacingstuds LList=333 Ibf Point Live Load Applied on stud check RLLpoint:=Spacingstuds•RLL2 d=567 Ibf Point Roof Live Load Applied on stud check SLpoi t:=Spacingstuds•SL2d=708 Ibf Point Snow Load Applied on stud check Windipt:=W,,Qii•Spacingstuds=33 Ibf Distributed lateral Wind load from wall ft lateral wind load on king stud can cause high deflection,size members for this deflection as well as axial loading. WP-5 WP-6 Rz H1 &V W K N N LL z NG YQ l�V Z "� •G O � X q� R1 W w R4 m Z i'S S m o ro = _ N N' d Q- xx N R3 2X6 2X6 WaB Panel I Shear Panel Label Reglon Shear Chsdc I ShearforcepMl��--Cor LC Hold-Do Label I Chord StraO Label I Tension Chedc I lie-Down Force[ID] WP5 St_(2)77_BdQ3 R1 .846 1196.359 10 HO19_5.5_1.25_DF NC .998 14025211 WP6 St 7116_8d@3 _DF1SP_6oI1 M T 7078.228 Member Shape Code Check Loc[fQ LC Shear Che,-K 2-2X8 .448 1.625 498 7wp�,'v7 WH-3 KING 2X6 .459 7.147 11 .162 WH-3 TRIM 2X6 .162 0 .000 TUD CHECK 2X6 .241 5.045 11 .063 Member Label Span Location[fq y[in] (n)1:1y Ratio LC 1 max 3.115 -.001 NC 13 1 min 1.625 -.021 2576 7 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El TALL WALL#7: WALL AND GENERAL SPECIFICATIONS: hwau=10.09 ft Height of Wall WALL PANEL-APPLIED FORCE CALCULATIONS: Lateral Loading: Awaii:=2694 ftz Max area of wall appling wind load to walls perpendicular to this tall wall Combined Point Load for all walls on this side of Pwind wp7:=Pwindl+�2•Pwindz)=14455.79 Ibf the building parallel to this tall wall Point Load Applied to the Corner of the Tall Wall: Lp:=100% Percentage of Required Force Applied to the Length of Tall Wall Forceappiied:=Pwind'Lp=15558.53 Ibf Force Applied to Tall Wall Wwau=24.53 psf Force Applied to face of Tall Wall Axial Loading: 12.25 ft Tribfioor:= —2 6.13 ft Trib length of Roof Trusses appling load on this tall wall DLiineor:=Tribfioor DLR=110 plf Linear Dead Load Applied on Tall Wall LLiineor:=Trib&or'LLf=245 plf Linear Roof Live Load Applied on Tall Wall MEMBERS-APPLIED FORCE CALCULATIONS: Header 1 Loading: Lheoder:=3.25 ft Design Header length Tribfioor=6.13 ft Trib length of Roof Trusses appling load on this tall wall DLiinear=110.25 plf Linear Dead Load Applied on Header LLiinear=245 plf Linear Roof Live Load Applied on Header Wind hwall tali •W 197 1 Linear Laterial Wind on Header lat:= wail= plf 2 King Stud 1 Loading: Tribroof=21.25 ft Trib length of Roof Trusses appling load on this tall wall Spacingstad5:=16 in Trib length this stud DLpoint:=DLlinear'Spacingst d5=147 Ibf Point Dead Load Applied on King stud LLpoint:=LLlinear'Spacingst,d5=327 Ibf Point Roof Live Load Applied on King stud Windiat:=Wwaii•Spacingstads=33 lbf Distributed lateral Wind load from wall ft lateral wind load on king stud can cause high deflection,size members for this deflection as well as axial loading. CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE \� 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El Wa0 Pane, Shear Panel Label GovLC Region Shear ar PorE tib J HOW -Down Label Cr7Dra SDav Label Tension Check Tie-Oown Forceyb St_7nn 8d@3 p4 914Check She 645991 10 HDU8-SDS25_3_DF-SP rlC 842 5693437 RISA Model of Tall Wall&Header Assembly 2-2X6 1-4 R4 R2 H 1 0 0 0 0 0 ! 0 0 0 0 0 0 o cri m cm co m co CIDw tail R1 N :-y W CID CID CID to CIDN N N N N N N u Z Y 2X6 i AL 3 F,lember Shape Code Check Loc[ft] LC Shear Check 2-2X8 .202 1,62h 5 .224 WP-7 AM-3 KING 2X6 .430 7.042 11 .160 :."P-7 l^.H-3 TRIU 2X6 069 Cl .000 :1rP-7 STUD CHECK 2X6 .219 5.045 11 .063 Member Label Span Location[ftj y[in] (n)U y Ratio 31W1 • • � 1 max 2.133 -.001 NC 1 min 1.625 -.008 6573 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El TALL WALL#8: WALL AND GENERAL SPECIFICATIONS: NOTE: Tall Wall#8 has no walls above it is required to support hwall=10.09 ft Height of Wall WALL PANEL-APPLIED FORCE CALCULATIONS: Lateral Loading: A,a111:=108 ft•(10 ft+6 ft)=1728 ft' Max area of wall appling wind load to walls perpendicular to this tall wall A,,a112:=63 ft•(10 ft+6 ft)=1008 ft' Awaa1 Wwan• +Awaii2 Pwind:= 2 =22960.63 1bf Combined Point Load for all walls on this side of 2 the building parallel to this tall wall Point Load Applied to the Corner of the Tall Wall: Lp:=100% Percentage of Required Force Applied to the Length of Tall Wall Forceapplied:=Pwind,Lp=22960.63 lbf Force Applied to Tall Wall Wwau=24.53 psf Force Applied to face of Tall Wall Axia Loading: Tribroof:= 2 2ft Trib length of Roof Trusses appling load on this tall wall DLlinear:=Tribroof'DLR=216 plf Linear Dead Load Applied on Tall Wall RLLlinear:=Tribroof•RLL=240 plf Linear Roof Live Load Applied on Tall Wall SLlinear:=Tribroof•SLR=300 plf Linear Snow Load Applied on Tall Wall Winduplift:=Tribroof•Wupiift=-234 plf Linear Wind Uplift Load Applied on Tall Wall MEMBERS-APPLIED FORCE CALCULATIONS: Header 1 Loading: Lheader:=6.25 ft Design Header length Tribroof=12 ft Trib length of Roof Trusses appling load on this tall wall DLlinear=216 plf Linear Dead Load Applied on Header RLLlinear=240 plf Linear Roof Live Load Applied on Header SLlinear=300 plf Linear Snow Load Applied on Header Windlat'= hwan tau .Wwail= Pf 197 1 Linear Laterial Wind on Header 2 King Stud 1 Loading: Tribroof=12 ft Trib length of Roof Trusses appling load on this tall wall Spacingstuds:=16 in Trib length this stud DLpoint:=Spacingstuds'DLlinear=288 lbf Point Dead Load Applied on King stud RLLpoint:=Spacingstuds'RLLlinear=320 lbf Point Roof Live Load Applied on King stud SLpoint:=Spacingstuds-SLiineor=400 lbf Point Snow Load Applied on King stud Windiat:=Wwa11•Spacingstuds=33 lbf Distributed lateral Wind load from wall ft lateral wind load on king stud can cause high deflection,size members for this deflection as well as axial loading. CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE (\� 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El jjIjjjWall Panel Rtow Shear Check Show Fom"b lj Gov LC I Hold-Down Label Chord SVaP Label Tension Check Tie-Down Forcejlb; I- N/A 874 487 78Q 70 HDU5-SDS2 5_0E-SP f!C 84' 4-50 7, RISA Model of Tall Wall&Header Assembly 2-2X6 0 0 o C- o 0 0 0 CD CD 0 0�0 CD 0 m[ 06 cfl _ m m co cfl ca cD m 04 R1� C14 co co R12 X X R9 X X R6 X X R3 X1 X N N �N N NN NN N NI 2X6 Member ShaFe Code Check Loc[ftj LC Shear ChecF. e • � 2-2X10 .633 3.12E 7 .427 WP-8 Vt'H-6 KING 2X6 .695 7.988 11 .250 WP-o l°'H-6 TRIIJ 2X6 .177 0 .000 WP8 STUD CHECK 2X6 .224 5.045 11 .063 Member Label Span Location)ft] y[in] (n)L'!y Ratio LC e r • � 1 max 6.185 -.001 NC 15 1 min 3.125 -.063 1323 7 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El TALL WALL#10,&11: WALL AND GENERAL SPECIFICATIONS: h,,,aii=10.09 ft Height of Tall Wall WALL PANEL-APPLIED FORCE CALCULATIONS: Lateral Loading: A,,a11:=75.75 ft• hwau+8 ft =1370.32 ftz Max area of wall appling wind load to walls perpendicular to this tall wall Await W wall' 2 Combined Point Load for all walls on this side of Pwnd:= 8404 Ibf 2 = the building parallel to this tall wall Point Load Applied to the Corner of the Tall Wall: Lp:=100% Percentage of Required Force Applied to the Length of Tall Wall Forceapplied:=Pwind'Lp=8403.67 Ibf Force Applied to Tall Wall Wwau=24.53 psf Force Applied to face of Tall Wall Axia Loading: Trib:=2 ft Trib length of Roof and floor appling load on this tall wall DLiinearr:=Trib•DLR=36 plf Linear roof Dead Load Applied on Tall Wall DLiinear:=Trib•DLf=30 plf Linear floor dead Load Applied on Tall Wall LLiinear:=Trib•(LLf)=80 plf Linear live Load Applied on Tall Wall RLLiinear:=Trib•RLL=40 plf Linear Roof Live Load Applied on Tall Wall SLiineor:=Trib•SLR=50 plf Linear Snow Load Applied on Tall Wall Wind piift:=Trib•W piift=-39 plf Linear Wind Uplift Load Applied on Tall Wall MEMBERS-APPLIED FORCE CALCULATIONS: Header 1 Loading: Lheoder:=5.25 ft Design Header length DLiinearr:=Trib•DLR=36 plf Linear roof Dead Load Applied on Header DLiinearf:=Trib•DLf=30 plf Linear floor Dead Load Applied on Header LLiinear:=Trib•(LLf)=80 plf Linear live Load Applied on Header RLLiinear:=Trib•RLL=40 plf Linear Roof Live Load Applied on Header SLiinear:=Trib•SLR=50 plf Linear Snow Load Applied on Header Wind hwan tali •W 197 1 Linear Laterial Wind on Header tat:= wail= Pf 2 King Stud 1 Loading: Tribroof=12 ft Trib length of Roof Trusses appling load on this tall wall Spacingstud5:=16 in Trib length this stud DLpoint:=(DLiinearr+DLlinearf)'Spacingstads=88 Ibf Point Dead Load Applied on King stud LLpoint:=LLlinear'Spacing,t,d5=107 Ibf Point Live Load Applied on King stud RLLpoinr:=RLLiinear'Spacingstad5=53 Ibf Point Roof Live Load Applied on King stud SLpoinr:=SLuneor•Spacingstads=67 Ibf Point Snow Load Applied on King stud CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for m Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El Winds,:=W,,a]]•Spacingsruds=33 bf Distributed lateral Wind load from wall ft lateral wind load on king stud can cause high deflection,size members for this deflection as well as axial loading. Wall Panel Shear Panel Label Region Shear Check Shear Force]IbAQ Gov LC Hold-Down Label Chord Strap Label Tension Check Tle-Down ForCe[ID] r 51_7/16_8d@4 NIA 756 a16.27 10 NC MST60 SPF IF Bolt 9791 4061 603 I.P11 1 S1_7/15_8d@3 I NIA 892 630.524 1 10 IHDU11-SDS2.5_5.5_I NC 1 967 1 9029.488 RISA Model of wp11(lower wall) 2-2X6 0 0 H1 0 0 0 0 0 0 cfl W ao co CO CS R3 N CV N W W OD (O X X X X N N N N 6 RISA Model of wp10(upper wall) �2X6 R2 H1 �qq U N U U U rp O O O O O O O CDr'1'A� m m 7 7 R4 R1 a°yFq CV N z m m W CD Y X X X X _o N N CV CV a � H 0 R3 a 2X6 lylember Label Span Location[ft] y[in] (n)LYy Ratio LC � � � 1 max 5.141 -.001 NC 13 Ij min 1 2.625 1 -.02 1 3328 1 9 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El TALL WALL#12,&13: WALL AND GENERAL SPECIFICATIONS: h,,aii=10.09 ft Height of Tall Wall WALL PANEL-APPLIED FORCE CALCULATIONS: Lateral Loading: A,,aii:=65.75 ft• hwau+8 ft =1189.42 ftz Max area of wall appling wind load to walls perpendicular to this tall wall Await W wall' _ 2 _ Combined Point Load for all walls on this side of Pwnd•— 2 —7294 Ibf the building parallel to this tall wall Point Load Applied to the Corner of the Tall Wall: Lp:=100% Percentage of Required Force Applied to the Length of Tall Wall Forceapplied:=Pwind'Lp=7294.28 Ibf Force Applied to Tall Wall Wwau=24.53 psf Force Applied to face of Tall Wall Axial Loading: Trib:=2 ft Trib length of Roof and floor appling load on this tall wall DLiinearr:=Trib•DLR=36 plf Linear roof Dead Load Applied on Tall Wall DLiinear:=Trib•DLf=30 plf Linear floor dead Load Applied on Tall Wall LLiinear:=Trib•(LLf)=80 plf Linear live Load Applied on Tall Wall RLLiinear:=Trib•RLL=40 plf Linear Roof Live Load Applied on Tall Wall SLiinear:=Trib•SLR=50 plf Linear Snow Load Applied on Tall Wall Wind piift:=Trib•W piift=-39 plf Linear Wind Uplift Load Applied on Tall Wall MEMBERS-APPLIED FORCE CALCULATIONS: Header 1 Loading: Lheoder:=5.25 ft Design Header length DLiinearr:=Trib•DLR=36 plf Linear roof Dead Load Applied on Header DLiinearf:=Trib•DLf=30 plf Linear floor Dead Load Applied on Header LLiinear:=Trib•(LLf)=80 plf Linear live Load Applied on Header RLLiinear:=Trib•RLL=40 plf Linear Roof Live Load Applied on Header SLiinear:=Trib•SLR=50 plf Linear Snow Load Applied on Header Windtat:= hwan tali •Wwail= Pf 197 1 Linear Laterial Wind on Header 2 King Stud 1 Loading: Trib=2 ft Trib length of Roof Trusses appling load on this tall wall Spacingstud5:=16 in Trib length this stud DLpoint:=(DLiineorr+DLlinearf)'Spacingstads=88 Ibf Point Dead Load Applied on King stud LLpoint:=LLlinear'Spacing,t,d5=107 Ibf Point Live Load Applied on King stud RLLpoinr:=RLLiinear'Spacingstad5=53 Ibf Point Roof Live Load Applied on King stud SLpoinr:=SLuneor•Spacingstads=67 Ibf Point Snow Load Applied on King stud Windiat:=Wwau•Spacingstads=33 lbf Distributed lateral Wind load from wall ft CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El lateral wind load on king stud can cause high deflection,size members for this deflection as well as axial loading. Wall Panel Shear Panel Label Region Snear Ctre Snear For Gov LC Hold- own Label Chord Strap Label Tension Check Tie-Do Gov LC S1_7n6 8oQ6 R1 4 61 164526 10 NC 1AST37_24_SPFIHF_Nai1 952 1428118 18 WP18A 51 7/15_8AQ6 NIA 882 314701 10 HDU4-SDS2.5_DF-SP NC 785 3584.458 18 RISA Model of wp13(lower wall) 2-2X6 0 o F HI o 0 0 0 0 0 W W CD R3 � � N N CV 1D 10 OD f0 X X X X N N N N 2X6 RISA Model of wp12(upper wall) wA 2-2X6 as O O 0 o O to CD g R1 S CV OD m N N 2X6 Member Shape Code Check Loc[ftj LC ShE_-arCheck- t 2-2X8 .430 3.12E 1E 1 ,1 ^dP-12-13 KIPJG6 2X6 .903 6.622 11 219 WP-12-13 TRI1,16 2X6 .049 0 400 WP-12- 33 STUD CHECK 2X6 .217 5.04E 11 .063 Member Label Span I I Location [ft] I y[in] I (n- LYyRatio • • � •• 1 max 5.794 -.001 NC 1 min 3.125 -.04 1972 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more in+ Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El TALL WALL#14: WALL AND GENERAL SPECIFICATIONS: hwau=10.09 ft Height of Tall Wall WALL PANEL-APPLIED FORCE CALCULATIONS: Lateral Loading: Awaii:=55.75 ft•(hwaii+6 ft)=897.02 ft2 Max area of wall appling wind load to walls perpendicular to this tall wall Awall W wall' 2 Combined Point Load for all walls on this side of Pwina:= 5501 Ibf 2 = the building parallel to this tall wall Point Load Applied to the Corner of the Tall Wall: Lp:=100% Percentage of Required Force Applied to the Length of Tall Wall Forceappiied:=Pwind'Lp=5501.09 Ibf Force Applied to Tall Wall Wwau=24.53 psf Force Applied to face of Tall Wall Axial Loading: Trib= 37 ft+8 in =18.83 ft Trib length of Roof appling load on this tall wall 2 DLiinearr:=Trib•DLR=339 plf Linear roof Dead Load Applied on Tall Wall RLLiinear:=Trib•RLL=377 plf Linear Roof Live Load Applied on Tall Wall SLiinear:=Trib•SLR=471 plf Linear Snow Load Applied on Tall Wall Windapiih:=Trib•Wapiift=-367 plf Linear Wind Uplift Load Applied on Tall Wall Wa,,PaneI Shear Panel Label Region Shear Check Shear Forcepbaq Gov LC Hoid-Down LOW Chortl Strap Label Tension Check Tie-0own Forcepbj S 1_7116_Ho@3 Rt .819 574.053 10 NC YSTC66_18_DF+SP_Nail 995 5823.309 RISA Model of wp14 �f6 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El TALL WALL#15: WALL AND GENERAL SPECIFICATIONS: hwau=10.09 ft Height of Tall Wall Note:this shear wall loads to beam-beam shall beam designed to support shear loads and hold down loads WALL PANEL-APPLIED FORCE CALCULATIONS: Lateral Loading: Forceappiied:=Pwind'LP=5501.09 Ibf Wwall=24.53 psf Axial Loading: Trib:= 46 ft+2 in =23.08 ft Trib length of Roof and floor appling load on this tall wall 2 DLiinearr:=Trib•DLR=416 plf Linear roof Dead Load Applied on Tall Wall RLLiinear:=Trib•RLL=462 plf Linear Roof Live Load Applied on Tall Wall SLiinear:=Trib•SLR=577 plf Linear Snow Load Applied on Tall Wall Windapiih:=Trib•Wapiift=-450 plf Linear Wind Uplift Load Applied on Tall Wall MEMBERS-APPLIED FORCE CALCULATIONS: Header 1 Loading: Lheoder:=5.25 ft Design Header length DLiinearr:=Trib•DLR=416 plf Linear roof Dead Load Applied on Header RLLiinear:=Trib•RLL=462 plf Linear Roof Live Load Applied on Header SLiinear:=Trib•SLR=577 plf Linear Snow Load Applied on Header Windlet:= hwal tali •Wwail=197 Pf 1 Linear Laterial Wind on Header 2 King Stud 1 Loading: Trib=23.08 ft Trib length of Roof Trusses appling load on this tall wall Spacingstud5:=16 in Trib length this stud DLpoinr:=DLiineorr'Spacingst,,ds=554 Ibf Point Dead Load Applied on King stud RLLpoinr:=RLLiinear'Spacing5tads=616 Ibf Point Roof Live Load Applied on King stud SLpoinr:=SLiineor'Spacingstads=769 Ibf Point Snow Load Applied on King stud Windiat:=Wwaii•Spacingstads=33 lbf Distributed lateral Wind load from wall ft lateral wind load on king stud can cause high deflection,size members for this deflection as well as axial loading. Wall Panel Shear Panel Label Region Shear Check Shear Force Gov LC Hold-Down Label Chord Strap Label Temlon Check Tie-Down Forcepbj S1 m 8d@4 WA 1 798 1 441.494 1 10 HDU5-SDS2.5_DF-SPI ric 1 852 1 4811,174 Member Shape Code Check Loc[ft; LC Shear Check 71.11P-1 3-2X10 .580 7.0181 .376 -15 KING 2-2X6 .671 7.988 11 .237 15 TRltvt 2X6 .130 0 .000 TUD CHECK 2X6 .236 5.04E 11 .063 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE \� 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El U U U U 11 01 01 0 0 TALL WALL#16,17,18: WALL AND GENERAL SPECIFICATIONS: hwaii rail=16.09 ft Height of Tall Wall Note:this shear wall loads to beam-beam shall beam designed to support shear loads and hold down loads WALL PANEL-APPLIED FORCE CALCULATIONS: Lateral Loading: Awaii:=(47 ft•(hw,,,+6 ft))=756.23 ftZ Max area of wall appling wind load to walls perpendicular to this tall wall '4wa11 W wall' P 2 4637.69J° = lb Shear point loads on wall wind'= 2 Wwai1=24.53 psf Axial Loading: 21.5 ft — Trib:= —10.75 ft Trib length of Roof and floor appling load on this tall wall 2 DLiinearr:=Trib•DLR=194 plf Linear roof Dead Load Applied on Tall Wall RLLiinear:=Trib•RLL=215 plf Linear Roof Live Load Applied on Tall Wall SLiinear:=Trib•SLR=269 plf Linear Snow Load Applied on Tall Wall Windapiih:=Trib•W piifr=-210 plf Linear Wind Uplift Load Applied on Tall Wall MEMBERS-APPLIED FORCE CALCULATIONS: Header 1 Loading: Lneader:=5.25 ft Design Header length DLiinearr:=Trib•DLR=194 plf Linear roof Dead Load Applied on Header RLLiinear:=Trib•RLL=215 plf Linear Roof Live Load Applied on Header SLiinear:=Trib•SLR=269 plf Linear Snow Load Applied on Header Windlat:= hwan tali •Wwall= Pf 197 1 Linear Laterial Wind on Header 2 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El King Stud 1 Loading: Trib=10.75 ft Trib length of Roof Trusses appling load on this tall wall Spacingstud5:=16 in Trib length this stud DLpoint:=DLlinearr'Spacingst d5=258 Ibf Point Dead Load Applied on King stud RLLpoint:=RLL/inear'Spacing, d5=287 Ibf Point Roof Live Load Applied on King stud SLpoinr:=SLuneor'Spacingstads=358 Ibf Point Snow Load Applied on King stud Wind/at:=WWau•Spacingstads=33 Ibf Distributed lateral Wind load from wall ft lateral wind load on king stud can cause high deflection,size members for this deflection as well as axial loading. Member Shape Code Check Loc(ftJ I LC Shear Check ArP-17 HEADER 3-2X10 .572 7.018 11 .179 WP-17 KING 4-2X6 .799 9.889 11 .106 WP-17 TRllvl 2X6 .089 0 .000 WP-17 STUD CHECK L 2X6 .604 8.045 11 .101 Wall Panel Shear Panel Label Region I Shear Check IshearForcepbql Gov LC I Hold-Down Label I Chord Strap Label I Tension Check Tie-Down Forcepbj WP16 S1_7/16_8d@6 Rt 0 0 N/A tic NC NC WP17 St_7/16_8d@6 N/A 1 927 33089 10 HDUS-SDS25_3_D NC 877 5933736 WP18 S1_7116_8d@6 R1 425 142251 18 HDU2-SDS25_DF- NC 1 774 1 2379.935 2-a6 ca C] O O CD CD X 6 m X R1'- Cv CN CV m to N N 2X6 CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El 2-2X6 R2 o v ca ca 0 0 0 cod H1 m to X m m m N N N R3 2X6 STEEL BEAM DESIGN: BM-1 Trlbbm:= 16 ft +2.5 ft=10.5 ft 2 DLbm:=Trlbbm•DLR=189 plf RLLbm:=Trlbbm•RLL=210 plf SLbm:=Trlbbm•SLR=263 plf WLbm_uplift:=Trlbbm•W pl;ft=—205 plf BM-2 Trlbbm 20 ft:= +2.5 ft=12.5 ft 2 DLbm:=Trlbbm•DLR=225 plf RLLbm:=Trlbbm•RLL=250 plf SLbm:=Trlbbm•SLR=313 plf WLbm_uplift:=Trlbbm•W pl;ft=—244 plf CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El BM-3 Tribbm:= 50 ft +2.5 fi=27.5 ft 2 DLbm:=Tribbm•DLR=495 plf RLLbm:=Tribbm•RLL=550 plf SLbm:=Tribbm•SLR=688 plf WLbm uplift:=Tribbm•W plift=—536 plf BM-4 ft Tribb := 22 m =11 ft 2 DLbm:=Tribbm•DLR+Tribbm•DLf+10 ft•DLW=483 plf LLbm:=Tribbm•LLf=440 plf RLLbm:=Tribbm•RLL=220 plf SLbm:=Tribbm•SLR=275 plf WLbm uplift:=Tribbm•W pli ft=—215 plf BM-5 Tribbm R:= 46 ft =23 ft 2 ft Tribbm F:= 21 4 =5.25 ft DLbm:=Tribbm_R'DLR+Tribbm_F'DLf+10 ft•DLW=613 plf LLbm:=Tribbm F•LLf=210 plf RLLbm:=Tribbm_R•RLL=460 plf SLbm:=TribbmR'SLR=575 plf WLbm_uplift:=Tribbm_R'Wuplifr=-449 plf BM-7 ft Tribbm_F:= 20 2 =loft DLbm:=TribbmF DLf+10 ft•DLW=270 plf LLbm:=Tribbm_F'LLf=400 plf BM-8 ft Tribbm_R:= 29 2 =14.5 ft ft Tribbm F:= 20 =10 ff' _ 2 DLbmR:=Tribbm R'DLR+10 ft•DLW=381 plf DLbmF:=TribbmF DLf=150 plf LLbm:=Tribbm_F'LLf=400 plf RLLbm:=Tribbm_R•RLL=290 plf SLbm:=Tribbm R'SLR=363 plf WLbm_uplift:=Tribbm ift_R'Wupl =-283 plf CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE \� 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El BM-9&10 Tribbm R:=2 l t p Tribbm F:=2 ft DLbmR:=Tribbm_R'DLR+10 ft•DL,,+Tribbm_F'DLf=186 plf LLb,,:=Tribbm F'LLf=80 plf RLLb,,,:=TribbmR•RLL=40 plf SLbm:=Tribbm R'SLR=50 plf WLbm_uplift:=Tribbm_R'Wuplift=-39 plf BM-11&13 Determin capacity of floor joists in order to determin beam spacing :I F O R T E M MEMBER REPORT PASSED Levu./AT TU9 FLOOR JOIST PETERM1ttNAT/O/Y 1 p"s)11718"TA®110 tr OC O.e2n LemTA 10' o n L 10 L 0 0 Au WWl—are measured from the o.Ls We.1 10 IMW tol left canuever e,01 All o.towns arc T—oreal Design Results Uslad Q L9.0- All—d ft aft LOP LWC:COmONinism IraeMn) Sysuan Fk- Member Type ,oni raerwer Reaclron Iron) 1063 Q 2 12- 1041(2 25'1 Pa—a f 10^1 100 10 D v 10 L LAN SPMW Batlag Ilse ReMoenhal Shear IDsi 1025 0 312- 1560 Pa95ea t66%l 1 DO 1 0 D.10 L(la Spans) Busing Code IBC 2015 Design Methoddagy ASO 14—W iFFfta 2649 @ 5'312- 3160 Passes f84%1 100 1.0 D.1.0 L LAA SP—) Live Load DM in) 018505.31 r 0254 Passes(V659) - 10 D 10 L LAN Spans) Total Load Dell Oh) 02D006312^ 0506 Passed(LI611) - 10 D.10L(AN Spans) T J Pro'•Rating 6a 40 p355ed ft Tribbm-!`:= 25 4 =6.25 ft DLbmR:=Tribbm F'DLR=113 plf LLbm:=Tribbm_F'(LL f+LLbottub)=1188 plf SLbm:=Tribbm F'SLR=156 plf ft Tribbm F:= 25 4 =6.25 ft DLbmR:=Tribbm_F'DLR=113 plf LLbm:=Tribbm F'LLf=250 plf SLbm:=Tribbm F'SLR=156 plf ft Tribbm_F:= 25 2 =12.5 ft DLbmR:=Tribbm F'DLR=225 plf LLbm:=Tribbm_F'LLf=500 plf SLb,,,:=Tribb,,,_F•SLR=313 plf CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information. Noesis Engineering Services, P.C. 19095 DESIGN ENGINEER: 208-932-2720(office) MIKE SHETLER LOT 33A BLOCK 1 Daniel Sharp, PE 1680 Woodruff Park PIONEER POINT/SETTLERS RIDGE REVIEWED BY: Idaho Falls, ID 83401 Philip Nash, El Memo., Shape Code Chm, LOCX LC I Shew ChOC%I LOC9P Dv I LC I Pnaom po7 Prwom pOl Mnyybmp040 ullmomp049 I CO EOn WB%20 844 1276 9 006 13.016 y 9 23127.998 175748.503 16766.467 26274834 1.437 Ht-la C-9 W4%13 801 0 9 ODO 0 y 19 23840.696 114670.659 7285.429 11964.8 1 HI-la C-7 W4%13 794 0 9 000 0 z 9 238"698 114670.659 7285.420 119648 1 HI-la BU•9 W8%10 783 6764 9 066 0 y 9 11920.662 88522754 4071.489 7695891 1135 H1.10 BM-8 W14%34 734 d.Sol 9 112 4.S01 y 9 22014.671 2994D1198 26447.1D6 455940S9 1.551 Hl-lb 1361•1 W14X34 710 12.151 7 074 24.302 y 7 41179.982 299401.198 2607.106 50104027 1.136 HI-15 BM-10 WB%10 684 65 9 064 0 y 9 1290856S 86622.75A 4071489 8144526 1136 H1-10 BU-7 W14X34 '646 30 5 215 30 y 5 237%586 299401.198 26447-105 53274597 1.729 H7-10 C-8 WS%16 641 0 9 000 0 z 17 46384363 141017964 11427146 18962064 1 H1-ta Ci2 W5%16 832 1 D 9 .ODD 0 y 19 463B4.364 141017.964 11427.145 189OZO54 I 1 HI-la DW3 W10%/9 598 6466 7 118 1217 y 7 30231842 168263473 8358203 27314709 114 HI-10 C-3 WS%16 -574 0 7 000 0 y 19 13059.488 141017.954 11427.146 11876.165 1 HI-la BU-11 W14X34 $44 $49 5 195 0 y 5 101230361 299401196 2607105 136227545 1931 H1-lb C-11 974%13 540 0 5 000 0 y 19 23940.698 114670.659 7285,429 110648 1 Hi-1a SM-4 W 18%55 483 14 556 7 104 14.556 y 9 101404 324 465029 94 46157 685 206181 249 163 H1-10 C-1 WS%16 .482 0 7 DDO 0 y 19 13059.488 141017.964 11427.145 11876.165 1 Hi-ta BM 15 W12X22 478 5 5 132 0 y 5 48641.201 194011976 9131737 UD91407 1136 H1-lb BU-13 W14X34 437 7.474 9 124 0 y 9 79414206 299401.198 2607,106 114204.7S1 1.614 HI-lb C-13 W013 423 0 9 D00 0 y 19 1 23940698 1 114570659 7285429 119648 1 H11a BM-12 Wta%55 404 11.799 5 037 0 y 5 7728803 485M 94 46157.685 141SIS989 1355 HI-lb BM-14 WIB%55 398 11799 5 040 0 y 5 77288.03 48502994 46157.685 155803947 1491 H1.10 C-12 W4%13 396 0 9 000 0 y 19 23840 698 114670 659 7285 429 119646 1 Ht-ta BM-6 W18%55 359 16.797 9 103 17.021 y 9 101388.289 485029.94 46157.6B5 181791911 1437 H1.10 SW2 W10%19 227 7.279 7 047 12.704 y 7 2774406 16B263473 8358.263 26173228 1157 H1-10 C-4 W4%13 202 0 7 DDO 0 y 19 30465618 114670.659 7285429 12552466 1 HI-1a BU-5 W1a%86 202 1112 9 081 0 y 9 356186241 75748503 120758483 394435050 1136 Ht-10 C-5 W4%13 154 13 9 DDO 0 y 19 23840698 114670.659 7285 A29 11964.8 1 H1-to• C$ W4%iJ 016 13 9 000 0 y 19 23840698 114670659 7285429 119648 1 Ht-t0 C-10 W4X73 015 13 9 ODO 0 19 238405B8 114670659 7285428 t19948 1 H7-1D CITY APPROVED PLANS PLANS MUST BE ON JOB SITE FOR ALL INSPECTIONS Created with PTC Mathcad Express. See www.mathcad.com for more information.